汽车空调软管测试要求
合集下载
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
3.2.1.10
Decompression Refrigerant Emissions (Short Loss Rate and Long Loss Rate)
4.3.10
3.2.1.11
4.3.11
3.2.1.11.1 Short Term Loss Rate
4.3.11.1
3.2.1.11.2 Long Term Loss Rate
0.030 g/cm2/year Max
4 无设备
6.0 Max
50 ppm Max
210 mg/m2 contaminants with 0.2 mm size Brinell Hardness < 95;contaminants with 0.05 mm size Brinell Hardness > 95; 200 ppm Max
DV test Section 3.2.1.3 3.2.1.7 3.2.1.7.1 3.2.1.7.2 3.2.1.7.3 Test Leakage Crystallization, Low Temperature Embrittlement and Vacuum Flattening Crystallization Low Temperature Embrittlement Vacuum Flattening a. The minimum diameter dimension b. The maximum permissible pressure increase c. Surface 4.3.7.3.1 Method 4.3.3 4.3.7
4.3.16 4.3.20
3.2.1.20.1 Pressure Cycling
4.3.20.1
3.2.1.20.2 Vibration
4.3.20.2
3.2.1.20.2.1 Allowable leakage is 0.6 g.
3.3.1.1.2. 2
3.2.1.21
Coupling Integrity
无设备
老化可进行 现有设备无法满足检漏要求 0.1g/year
无设备 老化可进行 现有设备无法满足检漏要求 0.1g/year
0
,3.2.1.22和3.2.1.24三个大项目
6 (Note 2)
设备达不到要求
a. No rotation or movement. b. Weight loss 5/16 2.6g;13/32 3.4g;5/8 5.3g;3/4 6.3g Max c. There shall be no evidence of hose distress, wrinkles, or degradation, tube material fatigue or tube weld fatigue. 24 + 1 for volatility (Note 2) Frequency Ratio (A2/A1) 200 Hz 0.10 (maximum) 1 600 Hz 0.03 (maximum) 1000 Hz 0.01 (maximum) a. After performing 4.3.23.10, refrigerant weight loss shall not exceed twice (2×) the value per Table 7. Note: Adjust refrigerant weight loss with material weight loss of the control sample. b. After performing 4.3.23.11, no visible degradation or damage is permitted. 6 (Note 2) c. After performing 4.3.23.12, % of Crimp difference must be not more than 5% of initial measurement. d. After performing 4.3.23.13, leakage shall not exceed limits documented in 3.2.1.3. e. After performing 4.3.23.14, no oil leakage or hose material degradation is permitted. GMW15272, Table A1 4 a.leakage is 0.6 g Max(See Note in 3.3.1.1.3). Charge according to 4.1.4.4.2; b. Perform Leak test per 4.3.3. 6 现有设备无法满足检漏要求 0.1g/year
如果不能满足捡漏要求,请优先看3.2.1.20 ,3.2.1.22和3.2.1.24三个大项目
Spec-2012 0.5 g/year max(Detector calibrated to alarm at 0.1g/year)
Number of Samples 10 4
evaluation(2012) 现有设备无法满足检漏要求 0.1g/year
4.3.11.7
3.2.1.12
Moisture Vapor Ingression
4.3.12
3.2.1.12.1 pH
3.2.1.12.2 Chloride content
3.2.1.13
Internal Cleanliness
4.3.13
3.2.1.16 3.2.1.20
Anion Pressure Cycling and Vibration
4 无法测试杂质硬度 3 无设备
a. After completion of the of pressure cycle test, there shall be no evidence of leaks, hose distress or degradation, tube material fatigue, or tube weld fatigue. b. For tensile test, the hose shall retain a minimum of 80% of the required tensile strength. c. For burst test, follow Acceptance Criteria per 3.2.1.19. d. Pressure Cycle test results must demonstrate the required reliability as stated in 3.2.3.2. Time or cycle:Repeat for 28 cycles (for 10 years) or 42 cycles (for 15 years) to complete one test life of 150 000 pressure cycles (for 10 years) or 225 000 (for 15 years)
4ቤተ መጻሕፍቲ ባይዱ3.21
3.2.1.22
Noise and Vibration
4.3.22
3.2.1.23
Thermal Pressure Resistance
4.3.23
3.2.1.24 3.2.1.25
Corrosion Resistance Heat Age
4.3.24 4.3.25
Note 2: See 3.2.3.2 备注 样品包括堵头长度800mm左右 右侧为客户标记的情况 标准中有寿命试验要求的,按照较长时间计算
(W1 - W2) - (W1' - W2') must be < 0.3 g. (W1 - W2) < 0.2 g. No visible external degradation (such as cracking, delamination, etc.) is acceptable. 80% max 0.8 mm Hg/minute No any visible signs cracking or degradation in the hose outer and/or inner surface a. Leakage rate 0.5 g/year max b. No visible degradation of adhesion between hose layers. c. No visible cracks.
现有设备无法满足检漏要求 0.1g/year
3
现有设备无法满足检漏要求 0.1g/year
80 ° 0.8 kg/m2/year C 90 ° 1.0 kg/m2/year Max C 8 (4 samples each) 80 ° 1.5 kg/m2/year C 90 ° 2.0 kg/m2/year Max C 现有设备无法满足检漏要求 0.1g/year