荧光探针的发展与应用
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Supplementary materials for:
Perylene diimide based “turn-on” fluorescence sensor for detection of
Pd2+ in mixed aqueous media
Hai-xia Wang a, b,*, Yue-he Lang a, Hui-xuan Wang a, Jing-jing Lou a, Hai-ming Guo a, b, Xi-you Li c,*
a School of Chemistry and Chemical Engineering, Key Laboratory of Green Chemical Media and Reactions of Ministry of Education, Henan Normal University, Xinxiang 453007, China
b School of Environmental Science, Henan Normal University, Xinxiang 453007, China
email: hxwang5270@ (H. Wang)
c School of Chemistry an
d Chemical Engineering, Shandong University, Jinan 250100, China email: xiyouli@ (X. Li)
Contents
Page S1: Title of the paper, authors along with the contents.
Page S2-S4: Copy of the 1H and 13C NMR spectra of PDI-1, PDI-2 and PDI-3.
Page S5:Photophysical properties of PDI-1, PDI-2and PDI-3derivatives in different solvents at room temperature; Fluorescence spectra change of PDI-2and PDI-3 upon addition of different metal(8.0 equiv) ions; UV-vis spectra of PDI-1 (6.0 μM) in the presence of different metal ions (8.0 equiv).
Page S6: Job’s plots in DMF/H2O (v/v, 7/1) and acetonitrile; Fluorescence spectra changes of PDI-1 (5.0 μM) in the presence of Pd2+in acetonitrile and chloroform;ESI mass spectra of PDI-1 in the presence of 1.0 equiv PdCl2 in CH3CN.
Page S7: Job’s plots of PDI-1 (5.0 μM)in the presence of Pd2+in chloroform; Influence of pH on fluorescence intensity of PDI-1 (5.0 μM) in the absence and presence of 1.0 eq Pd2+; Benesi-Hildebrand analysis results.
Fig. S1 1H NMR (400 MHz) spectrum of PDI-1 in CDCl3.
Fig. S213C NMR (100MHz) spectrum of PDI-1 in CDCl3.
Fig. S31H NMR (400 MHz) spectrum of PDI-2 in CDCl3.
Fig. S413C NMR (100 MHz) spectrum of PDI-2 in CDCl3.
Fig. S51H NMR (400 MHz) spectrum of PDI-3 in CDCl3.
Fig. S613C NMR (100 MHz) spectrum of PDI-3 in CDCl3.
Table S1: Photophysical properties of PDI-1, PDI-2 and PDI-3 derivatives in different solvents at room temperature
PDI-1 PDI-2 PDI-3
λabs m ax nm ㏒ε
M-1cm-1
λem
m ax
nm
Φ
F
λabs m ax㏒ελem m axΦF
nm M-1cm-1 nm
λabs
m ax
nm
㏒ε
M-1cm-1
λem
m ax
Φ
F
nm
Toluene 573 4.72 605 0.0062 572 4.58 603 0.080 572 4.64 604 0.49 DCE 577 4.70 613 0.021 577 4.53 608 0.083 577 4.63 611 0.44 DCM 578 4.70 614 0.010 578 4.52 614 0.090 578 4.63 613 0.50 THF 568 4.69 605 0.0043 569 4.65 598 0.082 567 4.63 600 0.36 Dioxane 567 4.73 596 0.0052 568 4.66 598 0.091 567 4.65 601 0.43 CH3CN 569 4.71 604 0.0063 569 4.64 604 0.079 568 4.09 601 0.39 DMSO 577 4.69 600 0.0030 578 4.57 611 0.041 577 4.40 614 0.24
Fig. S7 Fluorescence spectra change of PDI-2 (left) and PDI-3 (right) upon addition of different metal (8.0 equiv) ions including Cr3+, Mn2+, Fe3+, Co2+, Ni2+, Cu2+, Zn2+, Ag+, Cd2+, Hg2+, Pb2+ and Pd2+ in DMF/H2O (v/v, 7:1), λex = 540 nm, Slit: 2.5 nm; 5.0 nm.
Fig. S8 UV-vis spectra of chemosensor PDI-1 (6.0 μM)in the presence of different metal ions (8.0 equiv) of Mn2+, Co3+, Ni2+,Cu2+, Zn2+, Cd2+, Hg2+ and Pd2+ in DMF/H2O (v/v, 7:1). Inset showing the color change (left) before (right) after the addition of Pd2+ in visible light.