In addition, our shop provides you with various types ofpractical materials,such as educational essays, diaryappreciation,sentence excerpts,ancient poems,classic articles,topic composition,work summary,word parsing,copy excerpts,other materials and so on,want to know different data formats andwriting methods,please pay attention!
一、开机准备
1. 确保实验室环境整洁,无尘埃和腐蚀性气体。
2. 接通岛津高效液相色谱仪2010的电源线,打开仪器电源。
3. 按下仪器面板上的“ON”按钮,仪器开始自检。
4. 自检完成后,仪器进入待机状态,此时可以进行下一步操作。
二、系统设置
1. 设定色谱柱温度,根据样品特性选择适当的温度。
2. 设定流动相种类和流量,确保流动相符合实验要求。
3. 设定检测器灵敏度,根据样品浓度范围进行调整。
4. 设定数据处理软件的参数,如积分时间、基线扣除等。
三、样品制备
1. 准确称取一定量的样品,加入适量的流动相溶解,制备成待测溶液。
2. 如果需要,可以对样品进行过滤、脱气等预处理。
四、进样操作
1. 将样品溶液转移到进样瓶中。
2. 使用进样器将样品溶液引入色谱柱。
3. 注意控制进样速度,避免产生气泡和样品溅出。
五、分析操作
1. 按下仪器面板上的“运行”按钮,开始分析。
2. 观察仪器显示屏上的实时数据,如峰面积、保留时间等。
3. 当分析完成后,仪器会自动停止运行。
六、数据处理与结果输出
1. 连接计算机,启动数据处理软件。
2. 将仪器传输的数据导入软件中,进行峰面积计算、峰形观察等。
3. 根据实验结果,绘制chromatogram,并进行定量分析。
4. 保存和输出分析结果,如峰面积、保留时间等。
注意事项:
1. 操作过程中要避免剧烈震动和碰撞,以免影响仪器性能。
2. 定期检查仪器,确保各部件正常工作。
3. 注意样品溶液的保存和处理,避免样品降解和污染。
4. 及时清理进样器、色谱柱等,以保证分析结果的准确性。