SHIPPING AND PACKAGING QUALIFICATION PLAN
1) LARGE APPLIANCES
1.1 Surfaces identification
1.2 Test list
1.3 Qualification criteria
After the test, the unit must be fault free and with no visible defect; damages on the packaging is accepted but it must be possible further transportation.
1.4 Clamps
Test must be performed on 8 units.
Clamp force: 12 kN
Number of clamp attempt: 8 attempts on 8 units together (4 on top and 4 on bottom), 8 attempts on 1 single unit
Test procedure:
- clamp the units at max force
- lift the package
- carry the package for 10m
- lower the package at max speed and stop abruptly
1.5 Vibration test
Equipment: vibration table
Samples: 1 unit without load and 1 unit with load
Load: Load = (max stacked units – 1) x packaged unit mass Load applied on top of the unit
Procedure:
Acceleration: 0,52 g
Duration: 30min
If vibration table is not available, the following test in alternative: Frequency: 5Hz
Acceleration: 1,1g (vertical)
Duration: 30min
1.6 Impact test
To be performed with a drop table or an inclined plane.
Equipment:
Impacts from below:
Edge 5/3 under 10° on surface 3
Edge 2/3 under 10° on surface 3
Edge 4/3 under 10° on surface 3
Edge 6/3 under 10° on surface 3
Surface impacts:
Surfaces 2,3,4,5,6 under 0°
Drop height (free fall): 25cm
1.7 Stacking test
Stacking height: 6m/8m
Test duration: 30 days
2) PALLETIZED UNITS
2.1 Stacking test
Stacking with the maximum pallets for 4 weeks.; after the test each package must be in perfect condition.
2.2 Drop test
Drop on 6 different edges on a 10° from horizontal inclined surface.
Drop height based on previous table, for weights lower than 50kg, height drop is 52 cm. Packaging can be damaged, but the product must be intact.。