5-177851-4中文资料
CHEMLOK 5150 产品安全数据表说明书
![CHEMLOK 5150 产品安全数据表说明书](https://img.taocdn.com/s3/m/ebc24898185f312b3169a45177232f60dccce77c.png)
USA SAFETY DATA SHEET3000000027601. CHEMICAL PRODUCT AND COMPANY IDENTIFICATIONProduct name: CHEMLOK 5150 Product Use/Class:AdhesiveLORD Corporation 111 LORD DriveCary, NC 27511-7923 USATelephone: 814 868-3180Non-Transportation Emergency: 814 763-2345 Chemtrec 24 Hr Transportation Emergency No.800 424-9300 (Outside Continental U.S. 703 527-3887)EFFECTIVE DATE: 08/07/20172. HAZARDS IDENTIFICATIONGHS CLASSIFICATION:Flammable liquids Category 2 Acute toxicity Oral Category 4Acute toxicity Inhalation - Vapours Category 3Acute toxicity Inhalation - Dust and Mist Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 1ASpecific target organ systemic toxicity (single exposure) Category 1 Central nervous system, retina, Systemic toxicity, EyesSpecific target organ systemic toxicity (single exposure) Category 3Specific target organ systemic toxicity (repeated exposure) Category 1 Liver, Central nervous system, Eyes, retina Specific target organ systemic toxicity (repeated exposure) Category 2 Nervous system Hazardous to the aquatic environment - acute hazard Category 3 Hazardous to the aquatic environment - chronic hazard Category 3GHS LABEL ELEMENTS: Symbol(s)Signal WordD ANGERHazard StatementsHighly flammable liquid and vapor. Harmful if swallowed. Fatal if inhaled.Causes serious eye irritation.May damage fertility or the unborn child.Causes damage to organs.(Central nervous system, retina, Systemic toxicity, Eyes) May cause respiratory irritation. May cause drowsiness or dizziness.Causes damage to organs through prolonged or repeated exposure.(Liver, Central nervous system, Eyes, retina) May cause damage to organs through prolonged or repeated exposure.(Nervous system) Harmful to aquatic life.Harmful to aquatic life with long lasting effects.Precautionary StatementsPreventionKeep away from heat/sparks/open flames/hot surfaces. - No smoking.Ground/Bond container and receiving equipment.Use explosion-proof electrical/ventilating/lighting equipment.Use only non-sparking tools.Take precautionary measures against static discharge.Obtain special instructions before use.Do not handle until all safety precautions have been read and understood.Wear protective gloves/protective clothing/eye protection/face protection.Use personal protective equipment as required.Wear respiratory protection.Do not breathe dust/fume/gas/mist/vapors/spray.Wash thoroughly after handling.Do not eat, drink or smoke when using this product.Use only outdoors or in a well-ventilated area.Avoid release to the environment.ResponseIn case of fire: refer to section 5 of SDS for extinguishing media.Immediately call a POISON CENTER or doctor/physician.Specific treatment is urgent (see supplemental first aid instructions on this label).IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing.IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.Continue rinsing.Rinse mouth.StorageStore in a well-ventilated place. Keep cool.Store in a well-ventilated place. Keep container tightly closed.Store locked up.Disposal:Dispose of contents/container in accordance with waste/disposal laws and regulations of your country or particular locality.Other Hazards:This product contains component(s) which have the following warnings; however based on the GHS classification criteria of your country or locale, the product mixture may be outside the respective category(s).Acute: Vapor harmful; may affect the brain or nervous system causing dizziness, headache or nausea. May cause central nervous system depression characterized by the following progressive steps: headache, dizziness, staggering gait, confusion, unconsciousness or coma. Possible irritation of the respiratory system can occur causing a variety of symptoms such as dryness of the throat, tightness of the chest, and shortness of breath. The silane material in this product can hydrolyze to form ethanol. Ethanol can cause moderate eye irritation, moderate skin irritation; and can be absorbed through the skin causing headache, nausea, and general discomfort. Ethanol is toxic by inhalation. If swallowed, the silane material in this product can hydrolyze in the stomach to form ethanol. Refer to the ethanol warnings on this (M)SDS. Contains methanol; may be harmful or fatal if swallowed; ingestion of methanol may cause blindness or permanent eye damage. Cannot be made non-poisonous. Dermal absorption possible.May cause mild skin irritation.Chronic: May cause kidney damage. May affect the gastrointestinal system. This material contains methanol.Ingestion of methanol may cause permanent eye damage or blindness. ACGIH considers Ethyl alcohol to be an A3 carcinogen (confirmed animal carcinogen with unknown relevance in humans).3. COMPOSITION/INFORMATION ON INGREDIENTSChemical Name CAS Number RangeMethanol67-56-185 - 90%Ethyl alcohol64-17-5 1 - 5%Organic phosphonium chloride salt PROPRIETARY 1 - 5%Any "PROPRIETARY" component(s) in the above table is considered trade secret, thus the specific chemical and its exact concentration is being withheld.4. FIRST AID MEASURESFIRST AID - EYE CONTACT: Flush eyes immediately with large amount of water for at least 15 minutes holding eyelids open while flushing. Get prompt medical attention.FIRST AID - SKIN CONTACT: Flush contaminated skin with large amounts of water while removing contaminated clothing. Wash affected skin areas with soap and water. Get medical attention if symptoms occur.FIRST AID - INHALATION: Move person to fresh air. Restore and support continued breathing. If breathing is difficult, give oxygen. Get immediate medical attention.FIRST AID - INGESTION: If swallowed, do not induce vomiting. Call a physician or poison control center immediately for further instructions. Never give anything by mouth if victim is rapidly losing consciousness, unconscious or convulsing.5. FIRE-FIGHTING MEASURESSUITABLE EXTINGUISHING MEDIA: Carbon Dioxide, Dry Chemical, Foam, Water FogUNSUITABLE EXTINGUISHING MEDIA: Not determined for this product.SPECIFIC HAZARDS POSSIBLY ARISING FROM THE CHEMICAL: Flammable liquid and vapor. Keep containers tightly closed. Isolate from heat, electrical equipment, sparks, open flame, and other sources of ignition. Closed containers may rupture when exposed to extreme heat. Use water spray to keep fire exposed containers cool. During a fire, irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.SPECIAL PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIRE-FIGHTERS: Wear full firefighting protective clothing, including self-contained breathing apparatus (SCBA). Water spray may be ineffective. If water is used, fog nozzles are preferable.6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT, AND EMERGENCY PROCEDURES: Remove all sources of ignition (flame, hot surfaces, and electrical, static or frictional sparks). Avoid breathing vapors. Use self-contained breathing equipment. Avoid contact.ENVIRONMENTAL PRECAUTIONS: Do not contaminate bodies of water, waterways, or ditches, with chemical or used container.METHODS AND MATERIALS FOR CONTAINMENT AND CLEANUP: Keep non-essential personnel a safe distance away from the spill area. Notify appropriate authorities if necessary. Contain and remove with inert absorbent material and non-sparking tools. Avoid contact. Before attempting cleanup, refer to hazard caution information in other sections of the SDS form.7. HANDLING AND STORAGEHANDLING: Keep closure tight and container upright to prevent leakage. Ground and bond containers when transferring material. Because empty containers may retain product residue and flammable vapors, keep away from heat, sparks and flame; do not cut, puncture or weld on or near the empty container. Do not smoke where this product is used or stored. Avoid breathing of vapor or spray mists. Use with adequate ventilation. Avoid skin and eye contact. Wash thoroughly after handling. Do not handle until all safety precautions have been read and understood. Empty containers should not be re-used. Cannot be made non-poisonous.STORAGE: Do not store or use near heat, sparks, or open flame. Store drum out of sun and away from heat. Store only in well-ventilated areas. Do not puncture, drag, or slide container. Keep container closed when not in use. Refer to OSHA29CFR Part 1910.106 "Flammable and Combustible Liquids" for specific storage requirements.INCOMPATIBILITY: Strong acids, bases, and strong oxidizers.8. EXPOSURE CONTROLS/PERSONAL PROTECTION COMPONENT EXPOSURE LIMITChemical Name ACGIH TLV-TWA ACGIH TLV-STELOSHA PEL-TWAOSHA PEL-CEILINGSkinMethanol200 ppm250 ppm260 mg/m3200 ppmN.E.SEthyl alcohol N.E.1,000 ppm1,900 mg/m31,000 ppmN.E.N.A.Organic phosphoniumchloride saltN.E.N.E.N.E. N.E.N.A.N.A. - Not Applicable, N.E. - Not Established, S - Skin DesignationEngineering controls: Sufficient ventilation in pattern and volume should be provided in order to maintain air contaminant levels below recommended exposure limits. Caution: Solvent vapors are heavier than air and collect in lower levels of the work area. Sufficient ventilation (using explosion-proof equipment) should be provided to prevent flammable vapor/air mixtures from accumulating.PERSONAL PROTECTION MEASURES/EQUIPMENT:RESPIRATORY PROTECTION: Use a NIOSH approved chemical/mechanical filter respirator designed toremove a combination of particulates and organic vapor if occupational limits are exceeded. For emergencysituations, confined space use, or other conditions where exposure limits may be greatly exceeded, use an approved air-supplied respirator. For respirator use observe OSHA regulations (29CFR 1910.134) or use in accordance with applicable laws and regulations of your country or particular locality.SKIN PROTECTION: Use neoprene, nitrile, or rubber gloves to prevent skin contact.EYE PROTECTION: Use safety eyewear including safety glasses with side shields and chemical goggles where splashing may occur.OTHER PROTECTIVE EQUIPMENT: Use disposable or impervious clothing if work clothing contamination is likely. Remove and wash contaminated clothing before reuse.HYGIENIC PRACTICES: Wash hands before eating, smoking, or using toilet facility. Do not smoke in anychemical handling or storage area. Food or beverages should not be consumed anywhere this product is handled or stored. Wash thoroughly after handling.9. PHYSICAL AND CHEMICAL PROPERTIESTypical values, not to be used for specification purposes.ODOR: Alcohol VAPOR PRESSURE: N.D.APPEARANCE: Clear VAPOR DENSITY: Heavier than Air PHYSICAL STATE: Liquid LOWER EXPLOSIVE LIMIT: 4.3 %(V)FLASH POINT: 43 °F, 6 °C SetaflashClosed CupUPPER EXPLOSIVE LIMIT: 36.5 %(V)BOILING RANGE: 65 - 100 °C EVAPORATION RATE: Faster than n-butyl-acetate.AUTOIGNITION TEMPERATURE:N.D.DENSITY: 0.82 g/cm3 - 6.85 lb/gal DECOMPOSITION TEMPERATURE:N.D. VISCOSITY, DYNAMIC: N.D.ODOR THRESHOLD: N.D.VISCOSITY, KINEMATIC: N.D.SOLUBILITY IN H2O: Insoluble VOLATILE BY WEIGHT: 94.65 %pH: N.A.VOLATILE BY VOLUME: 96.15 %FREEZE POINT: N.D. VOC CALCULATED: 6.33 lb/gal, 758 g/l COEFFICIENT OF WATER/OILDISTRIBUTION:N.D.LEGEND: N.A. - Not Applicable, N.E. - Not Established, N.D. - Not Determined10. STABILITY AND REACTIVITYHAZARDOUS POLYMERIZATION: Hazardous polymerization will not occur under normal conditions.STABILITY: Product is stable under normal storage conditions.CONDITIONS TO AVOID: High temperatures. Sources of ignition.INCOMPATIBILITY: Strong acids, bases, and strong oxidizers.HAZARDOUS DECOMPOSITION PRODUCTS: Oxides of nitrogen, Carbon monoxide, carbon dioxide, Oxides of silicon11. TOXICOLOGICAL INFORMATIONEXPOSURE PATH: Refer to section 2 of this SDS.SYMPTOMS:Refer to section 2 of this SDS.TOXICITY MEASURES:Chemical Name LD50/LC50Methanol Oral LD50: Rat6,200 mg/kgDermal LD50: Rabbit15,800 mg/kgInhalation LC50: Rat22500 ppm/8 hEthyl alcohol Oral LD50: Rat7,060 mg/kgInhalation LC50: Rat124.7 mg/l/4 hOrganic phosphonium chloride salt Oral LD50: Rat43 mg/kgGHS LC50 (vapour): Acute toxicity point estimate3 mg/l GHS LC50 (dustand mist): Acute toxicity point estimate0.05 mg/lGerm cell mutagenicity: No classification proposedCarcinogenicity: No classification proposedReproductive toxicity: Category 1A - May damage fertility or the unborn child.Components contributing to classification: Methanol.12. ECOLOGICAL INFORMATIONECOTOXICITY:Chemical Name EcotoxicityMethanol Fish: Pimephales promelas28,200 mg/l96 h flow-throughPimephales promelas> 100 mg/l96 h StaticOncorhynchus mykiss19,500 - 20,700 mg/l96 h flow-throughLepomis macrochirus13,500 - 17,600 mg/l96 h flow-throughEthyl alcohol Fish: Pimephales promelas> 100 mg/l96 h StaticPimephales promelas13,400 - 15,100 mg/l96 h flow-throughInvertebrates: Daphnia magna9,268 - 14,221 mg/l48 hDaphnia magna2 mg/l48 h StaticOrganic phosphonium chloride salt N.D.PERSISTENCE AND DEGRADABILITY:Not determined for this product.BIOACCUMULATIVE: Not determined for this product.MOBILITY IN SOIL: Not determined for this product.OTHER ADVERSE EFFECTS: Not determined for this product.13. DISPOSAL CONSIDERATIONSDISPOSAL METHOD: Disposal should be done in accordance with Federal (40CFR Part 261), state and local environmental control regulations. If waste is determined to be hazardous, use licensed hazardous waste transporter and disposal facility.14. TRANSPORT INFORMATIONUS DOT RoadDOT Proper Shipping Name: AdhesivesDOT Hazard Class: 3SECONDARY HAZARD: NoneDOT UN/NA Number: 1133Packing Group: IIEmergency Response Guide Number: 128IATA CargoPROPER SHIPPING NAME: AdhesivesDOT Hazard Class: 3HAZARD CLASS: NoneUN-NUMBER: 1133PACKING GROUP: IIEMS: 3LIMDGPROPER SHIPPING NAME: AdhesivesDOT Hazard Class: 3HAZARD CLASS: NoneUN-NUMBER: 1133PACKING GROUP: IIEMS: F-EThe listed transportation classification applies to non-bulk shipments. It does not address regulatory variations due to changes in package size, mode of shipment or other regulatory descriptors. For the most accurate shipping information, refer to your transportation/compliance department.15. REGULATORY INFORMATIONU.S. FEDERAL REGULATIONS: AS FOLLOWS:SARA SECTION 313This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendment and Reauthorization Act of 1986 and 40 CFR part 372.:Chemical Name CAS Number Weight % Less ThanMethanol67-56-190.0%TOXIC SUBSTANCES CONTROL ACT:INVENTORY STATUSThe chemical substances in this product are on the TSCA Section 8 Inventory.EXPORT NOTIFICATIONThis product contains the following chemical substances subject to the reporting requirements of TSCA 12(B) if exported from the United States:None16. OTHER INFORMATIONUnder HazCom 2012 it is optional to continue using the HMIS rating system. It is important to ensure employees have been trained to recognize the different numeric ratings associated with the HazCom 2012 and HMIS schemes.HMIS RATINGS - HEALTH: 2* FLAMMABILITY: 3 PHYSICAL HAZARD: 1* - Indicates a chronic hazard; see Section 2Revision: Section 2Effective Date: 08/07/2017DISCLAIMERThe information contained herein is, to the best of our knowledge and belief, accurate. However, since the conditions of handling and use are beyond our control, we make no guarantee of results, and assume no liability for damages incurred by use of this material. It is the responsibility of the user to comply with all applicable federal, state and local laws and regulations.。
5347中文资料
![5347中文资料](https://img.taocdn.com/s3/m/7e158510964bcf84b9d57b65.png)
SMOKE DETECTORWITH INTERCONNECT AND TIMERAlways order by complete part number:A5347CA .5347FEATURESs Interconnect Up to 125 Detectors s Piezoelectric Horn Drivers Guard Outputs for Detector Input s Pulse Testing for Low Battery s Power-ON Resets Internal Timer & Control for Reduced Sensitivity s Built-In Hysteresis Reduces False TriggeringData Sheet26110.2The A5347CA is a low-current, CMOS circuit providing all of the required features for an ionization-type smoke detector. A networking capability allows as many as 125 units to be interconnected so that if any unit senses smoke, all units will sound an alarm. In addition,special features are incorporated to facilitate alignment and test of the finished smoke detector. This device is designed to comply with Underwriters Laboratories Specification UL217.The internal oscillator and timing circuitry keeps standby power to a minimum by powering down the device for 1.66 seconds and sensing smoke for only 10 ms. Every 24 on/off cycles, a check is made for low battery condition. By substituting other types of sensors, or a switch for the ionization detector, this very-low power device can be used in numerous other battery-operated safety/security applications.The A5347CA is supplied in a low-cost, 16-pin dual in-line plastic package. It is rated for continuous operation over the temperature range of 0°C to +50°C.115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-50009 VIN+V569141516NOTE 1:Negative current is defined as coming out of (sourcing) the specified device pin.NOTE 2:Alarm (Smoke) Condition is defined as V15< V13; No Alarm (No Smoke) Condition as V15> V13.Continued next page . . .ELECTRICAL CHARACTERISTICS at TA= +25°C, V DD = 9.0 V, V SS = 0 V, C12= 0.1 µF,R 7= 8.2 MΩ (unless otherwise noted).5347SMOKE DETECTOR with INTERCONNECT and TIMER115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-5000ELECTRICAL CHARACTERISTICS continuedNOTE 1:Negative current is defined as coming out of (sourcing) the specified device pin.NOTE 2:Alarm (Smoke) Condition is defined as V 15 < V 13; No Alarm (No Smoke) Condition as V 15 > V 13.CIRCUIT DESCRIPTIONThe A5347CA is a low-current CMOS circuit providing all of the required features for an ionization-type smoke detector.Oscillator. An internal oscillator operates with a period of 1.67seconds during no-smoke conditions. Every 1.67 seconds, internal power is applied to the entire circuit and a check is made for smoke.Every 24 clock cycles (40 seconds), the LED is pulsed and a check is made for low battery by comparing V DD to an internal reference.Since very-low currents are used in the device, the oscillator capacitor at pin 12 should be a low-leakage type (PTFE, polystyrene, or polypropylene).Detector Circuitry. When smoke is detected, the resistor dividernetwork that sets the sensitivity (smoke trip point) is altered to increase the sensitivity set voltage (pin 13) by typically 130 mV with no external connections to pins 3 or 13. This provides hysteresis and reduces false triggering. An active guard is provided on both pins adjacent to the detector input (pin 15). The voltage at pins 14 and 16 will be within 100 mV of the input. This will keep surface leakage currents to aminimum and provide a method of measuring the input voltage without loading the ionization chamber. The active guard amplifier is not power strobed and thus provides constant protection from surface leakage currents. The detector input has internal diode protection against static damage.Alarm Circuitry. If smoke is detected, the oscillator period changes to 40 ms and the horn is enabled. The horn output is typically 160 ms ON, 80 ms OFF. During the OFF time, smoke is again checked and will inhibit further alarm output if smoke is not sensed.During smoke conditions the low battery alarm is inhibited and the LED is driven at a 1 Hz rate.Sensitivity Adjust. The detector sensitivity to smoke is set internally by a voltage divider connected between V DD and V SS . Thesensitivity can be externally adjusted to the individual characteristics of the ionization chamber by connecting a resistor between pin 13 and V DD , or between pin 13 and V SS .Low Battery. The low battery threshold is set internally by a voltage divider connected between V DD and V SS . The threshold can be increased by connecting a resistor between pin 3 and V DD . The threshold can be de-creased by connecting a resistor between pin 3 and V SS . The battery voltage level is checked every 40 seconds during the 10 mA,10 ms LED pulse. If an LED is not used, it should be replaced with an equivalentresistor (typically 500 Ω to 1000 Ω) such that the battery loading remains at 10 mA.Timer. An internal timer is provided that can be used in various configurations to allow for a period of reduced smoke detector sensitiv-ity (“hush”). When a high-to-low transition occurs at pin 1, the internal timer is reset,the timer mode enabled, and the circuit reset to a no alarm condition. The LED will flash at a 10 second rate. If the level of smoke is increased such that the reduced sensitivity level is reached, the device will go into the alarm condition. The timer, however, will continue to completion of the nominal 10-1/4minute period (368 clock cycles). If the timer mode is not used, pin 1 should be tied low.I/O. A connection is provided at pin 2 to allow multiple smoke detec-tors to be commoned. If any single unit detects smoke (I/O is driven high), all connected units will sound their associated horns after a nominal 3 second delay. The LED is suppressed when an alarm is signaled from an interconnected unit.Testing. On power up, all internal counters are reset. Internal test circuitry allows for low battery check by holding pins 8 and 12 low during power up, then reducing V DD and monitoring HORN 1 (pin 10).All functional tests can be accelerated by driving pin 12 with a 2 kHz square wave. The 10 ms strobe period must be maintained for proper operation of the comparator circuitry.115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-5000TIMING DIAGRAMS IN TYPICAL APPLICATIONNON-TIMER MODETIMER MODEV12OSC. CAPINTERNAL CLOCKLEDHORNDwg. WC-005TIMER STARTTIMER OUTV15 > V13 (NO SMOKE)V15 < V13 (SMOKE)V12OSC. CAPINTERNAL CLOCKLED SMOKE COMPARATORSMOKE CHAMBERHORNDwg. WC-003I/O OPERATIONHORN ONOFFHORN NOT SELF COMPLETING WHEN IN REMOTE ONLY ALARMINTERNAL CLOCKHORNV2 IN I/O4 CYCLES 2 CYCLES40 ms1.67 s72 CLOCK CYCLESV2 OUT I/OINTERNAL CLOCKLOCAL ALARM MODEREMOTE ALARM MODEDwg. WC-004HORN ONOFFHORN5347SMOKE DETECTOR with INTERCONNECT and TIMER115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-5000Dimensions in Inches (controlling dimensions)Dimensions in Millimeters(for reference only)Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the design of its products.Components made under military approvals will be in accordance with the approval requirements.The information included herein is believed to be accurate and reliable. However, AllegroMicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.NOTES: 1.Lead thickness is measured at seatingplane or below.2.Lead spacing tolerance is non-cumulative.3.Exact body and lead configuration at vendor’s option within limits shown.Dwg. MA-001-16A inDwg. MA-001-16A mm。
1533-1;1511-1;1510-1;1507-1;中文规格书,Datasheet资料
![1533-1;1511-1;1510-1;1507-1;中文规格书,Datasheet资料](https://img.taocdn.com/s3/m/8a7aef64561252d380eb6ea4.png)
1559
.043 [1.09] DIA. THRU
.097 [2.5]
L L
.061 [1.55]
L
.062 [1.57] .071 [1.80]
L
.082 [2.08] .072 [1.83]
Staking Tool No. TL-2 CAT. NO. L 1562-1 .054 (1.37) 1562-2 .084 (2.13) 1562-3 .115 (2.9) 1562-4 .147 (3.7)
Staking Tool No. TL-2 CAT. NO. 1559-1 1559-2 1559-3 1559-4 L .062 (1.57) .094 (2.39) .125 (3.2) .156 (3.9)
Staking Tool Special Order CAT. NO. L 1633-1 .051 (1.30) 1633-2 .082 (2.08) 1633-3 .113 (2.8) 1633-4 .145 (3.6)
1582
.055 [1.40] DIA. THRU .109 [2.8] .328 [8.4] .156 [4.0] .187 [4.8] .150 [3.8]
1509
.078 [1.98] DIA. THRU .093 [2.36] .312 [7.9] L .072 [1.83]
1583
.050 [1.27] (4) PLS .186 [4.72] .145 [3.68] (2) PLS .187 [4.75] L .164 [4.17]
TUBULAR TURRETS
1562
.043 [1.09] DIA. THRU .093 [2.36] .125 [3.2] .156 [4.0] .125 [3.2] .187 [4.8]
Nexans___售__表
![Nexans___售__表](https://img.taocdn.com/s3/m/5b78bee84afe04a1b071de3c.png)
散货项目业绩表序号电缆型号电缆规格数量(米)项目名称RHEYFIRM (RS) FLAT(N)TSFLCGCWOEUS4x35 6/10kV 300RHEYCORD(RTS) (N)SHTOEU-J0.6/1KV 24x2.53004X3512804X105604X44908X2.54708X1.517903RHEYFIRM(RTS)(N)TSCGEWTOEUS 6/10KV3X35+1X16+(12X2.5)C+OFE12G62.5/125500越南海防一期卸船机项目RHEYFIRM (RTS )(N )TSCGEWTOEUS OFE 6/10kV 3X25+2X25/2+6G62.5/125350RHEYFIRM (RTS )(N )TSCGEWTOEUS OFE 6/10kV 3X25+2X25/2+6G62.5/1253505RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10kV 3x35+1x16+(10x2.5)C+OFE12G62.5/125250浙江老塘山卸船机项目6RHEYFIRM(RS)FLAT(N)TSFLCGC WOEUS6/10 KV 4X35250贵港电厂斗轮机项目1RHEYFIRM(RTS) (N)TSCGEWTOEUS 6/10kv3x35+1x25+1x(12x2.5)C+6G62.5/125560南京热电斗轮机项目2RHEYFIRM(RTS) (N)TSCGEWTOEUS6/10kv3x35+1x16+1x(12x2.5)C+6E9/125260南京港卸船机项目1RHEYFIRM(RTS)(N)TSCGEWTOEUS OFE6/10kv 3X70+2X35/2+12G62.5/125640首钢曹妃甸卸船机项目1RHEYFIRM(RTS)(N)TSKCGEWTOEUS OFE 6/10kV 3x35/25+2x(4x2,5)C+OFE6G62,5/125822防城港卸船机项目2RHEYFIRM(RS)FLAT(N)TSFLCGC WOEUS6/10 KV 3X50/50+OFE6G62.5/125528南京港散货卸船机项目RHYECORD-OFE 12G62.5/1251240 RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10KV 3X50+3X25/3840RHEYFESTOON (N)3GRD5G 0.6/1KV 12X1.5605RHEYFESTOON (N)3GRD5G0.6/1KV 12X1.56050.6/1 KV 1X15024920.6/1 KV 4X41896中国华电工程集团有限公司4杭州华新机电工程有限公司无锡工力工程机械厂上海电力环保设备总厂有限公司中船第九设计研究院工程有限公司ABB(中国)1湛江卸船机项目12越南海防二期卸船机项目无锡电厂斗轮机项目福建储运卸船机项目RHEYFLAT-N NGFLGOEU-J RHEYFESTOON (N)3GRD5G0.6/1 KV 4X103700.6/1 KV 4X16288RHEYFESTOON (C)(N)3GRDGC5G (6X(2X1)C)C 580RHEYFESTOON (C)(N)3GRDGC5G 12X2.5 C950RHEYFESTOON (N)3GRD5G 1X2405120RHEYFESTOON (N)3GRD5G 18X1.52560RHEYFESTOON (N)3GRD5G 18X2.51280RHEYFESTOON (N)3GRD5G 1X955120RHEYFESTOON (N)3GRD5G6X(2X1)C 1280RHEYFESTOON (N)3GRD5G 1X1507040RHEYFESTOON (N)3GRD5G 4X25640RHEYFESTOON (N)3GRD5G 1X502560RHEYCORD-OFE M 12G62.5/1251280RHEYFIRM(RTS)(N)TSCGEWTOEUS OFE6/10KV 3X70+2X35/2+12G62.5/125u1040RHEYFIRM(RTS)(N)TSCGEWTOEUS 6/10 KV 3x50/25+2x(6x2.5)C+OFE12G62.5/125340RHEYCORD-OFE M12G62.5/1252204X42004X162001X352006X(2X1)C43218X2.5297RHEYCORD-OFE M12G62.5/125400RHEYCORD(RTS) (N)SHTOEU-J 25X2.5+1X(12E9/125)530RHEYFIRM(RTS)(N)TSCGEWTOEUS OFE 6/10kV 3X50+3X25/3380RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10kV 3X35+3X25/31503RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10KV 3X35+2X25/2 OFE 6G62.5/125870新加坡PSA STS 项目4RHEYFIRM(RTS)(N)TSCGEWTOEUS OFE6/10kV 3x70+2x35/2+6 OFE720韩国釜山STS 项目5RHEYFIRM(RTS)(N)TSCGEWTOEU S OFE 3.6/6kV 3x120 + 2 x 70/2 + 1FO 18E(9/125mm SM )1472新加坡PSA STS 项目1RHEYFIRM(RTS)(N)TSCGEWTOEUS 6/10KV3X185+1X95+2X(2X2.5)C+1X(6G62.5/125)6402RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10KV3X185+1X95+2X(2X2.5)C+1X(6G62.5/125)28054817宝钢罗泾280T行车项目扬州江都船厂龙门吊项目中船江南重工股份有限公司上海振华港机(集团)股份有限公司1印度卸船机项目大连重工.起重集团有限公司2RHEYFESTOON (N)3GRD5G 宝钢湛江码头卸船机项目11威海卸船机项目RHEYFESTOON (N)3GRD5G集装箱项目业绩表序号电缆型号电缆规格数量(米)项目名称1RHEYCORD(BS) YSLZ3SSOE-J 300/500 36X2.5471岳阳RTG 项目RHEYFIRM(RTS)(N)TSCGEWTOEUS8.7/15kV 3X25+3X25/3760RHEYCORD(BS) YSLZ3SSOE-J 300/500 36X2.5424RHEYCORD-OFE M 12G62.5/125400RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10kV 3X25+3X25/3380RHEYCORD(BS) YSLZ3SSOE-J 300/500 36X2.5197RHEYCORD-OFE M12G62.5/125190RHEYCORD(RTS)(N)SHTOEU-J 0.6/1 KV 3x120+3x70/32240RHEYCORD(RTS)(N)SHTOEU-J0.6/1 KV 3x120+3x70/31280RHEYCORD(RTS)(N)SHTOEU-J 0.6/1 KV 3x150+3x70/34480RHEYCORD(RTS)(N)SHTOEU-J0.6/1 KV 3x150+3x70/325605RHEYCORD(RTS) (N)SHTOEU-J SPREADER 44x2.5166福州RTG 项目6RHEYCORD(RTS) (N)SHTOEU-J3x120+3x70/32100韩国仁川STS 项目RHEYFIRM(RTS)(N)TSCGEWTOEUS3.6/6 KV 3x25+3x25/3960RHEYCORD(BS) YSLZ3SOE-J 300/500V 42x2.5110RHEYFESTOON(N)3GRD5G0.6/1KV 4X25258RHEYFESTOON(N)3GRD5G 0.6/1KV 24X2.5258RHEYFESTOON(N)3GRD5G 0.6/1KV 6X(2X1)C 258RHEYCORD OFE M12G62.5/125278RHEYFIRM(RTS)(N)TSCGEWTOEUS6/10 KV 3x50+2x25/2+6E9/1252502RHEYCORD(RTS)(N)SHTOEU-J SPREADER0.6/1KV 56x2.5552RHEYFESTOON(N)3GRD5G0.6/1KV 5X251146RHEYFESTOON(N)3GRD5G 0.6/1KV 18X2.51337RHEYFESTOON(N)3GRD5G 0.6/1KV 6X(2X1)C 1337RHEYCORD OFE M12G62.5/1251400RHECORD(RTS)(N)SHTOEU-J0.6/1 KV 3X95+2X50/2+(2X2.5)C 5400RHEYCORD(BS) YSLZ3SOE0.6/1kv 36X2.545610H07RNF,RHEYFLEX592887深圳大铲湾RTG 项目RHEYFIRM(RTS)(N)TSCGEWTOEUS12/20kV 3X25+3X25/31160上海振华港机(集团)股份有限公司2津唐港1期STS 项目3津唐港2期STS 项目4天津欧亚E-RTG 项目7南通港STS 项目8宁波梅山STS 项目9宁波梅山E-RGT 项目大连重工.起重集团有限公司RHEYCORD(BS) YSLZ3SSOE-J 300/500 54X2.5320RHEYFESTOON(C) (N)3GRDGC5G3X16+3X16/3 C 2560RHEYFESTOON (N)3GRD5G 12X2.52560RHEYFESTOON (N)3GRD5G 6X(2X1)C 1280RHEYFESTOON (N)3GRD5G 4X101280RHEYCORD-OFE M12G62.5/125740RHEYFIRM (N)TSCGEWTOEUS OFE8.7/15 kV 3x35+2x25/2+12G(62.5/125)570RHEYCORD(RTS) (N)SHTOEU-J spreader44x2.51653RHEYFIRM (RTS)(N)TSCGEWTOEUS OFE 6/10kV 3x95+2x50/2+12E 9/125µ470印度卸船机项目RHEYFESTOON(N)3GRD5G 0.6/1KV 12x2.52240RHEYFESTOON(C)(N)3GRDGC5G 0.6/1KV 3X25+3X16/31120RHEYFESTOON(N)3GRD5G 0.6/1KV 4X10560RHEYFESTOON(N)3GRD5G0.6/1KV 4X161120RHEYFESTOON(N)3GRD5G 0.6/1KV 1X50560RHEYFESTOON(N)3GRD5G 0.6/1KV 6X(2X1)C 1120RHEYCORD-OFE M 12G62.5/125600RHEYFIRM(RTS)(N)TSCGEWTOEUS 12/20KV 3X25+3X25/31200RHEYCORD(BS)YSLZ3SOE-J0.6/1KV 54x2.53205RHEYFIRM (RTS )(N )TSCGEWTOEUS8.7/15kV 3X25+3X25/31800泰国曼谷港备件项目RHEYFESTOON(N)3GRD5G 0.6/1KV 12x2.52240RHEYFESTOON(C)(N)3GRDGC5G 0.6/1KV 3X25+3X16/3c 1120RHEYFESTOON(N)3GRD5G 0.6/1KV 4X10560RHEYFESTOON(N)3GRD5G0.6/1KV 4X161120RHEYFESTOON(N)3GRD5G 0.6/1KV 1X50560RHEYFESTOON(N)3GRD5G 0.6/1KV 6X(2X1)C 1120RHEYCORD-OFE M 12G62.5/125600RHEYFIRM(RTS)(N)TSCGEWTOEUS 8.7/15KV 3x25+3x25/31000RHEYCORD(BS)YSLZ3SOE-J 0.6/1KV 54x2.5320RHEYCORD(RTS)(N)SHTOEU-J SPREADER0.6/1 kv 44x2.5165RHEYFIRM (N)TSCGEWTOEUS OFE8.7/15 kV 3x35+2x25/2+6FO5701BUFLEX X'Prem6/10(12)KV 3X35+3X1033602RHEYCORD(BS)YSLZ3SOE-J42X2.5465659732中铁山桥集团工程机械有限公司中铁集装箱轨道吊项目6泰国曼谷港三期STS项目7东营港二期多用途门机项目4泰国曼谷港二期STS 项目泰国曼谷港一期STS 项目12东营港一期多用途门机项目。
DL4754A中文资料
![DL4754A中文资料](https://img.taocdn.com/s3/m/4395d2d926fff705cc170aba.png)
Zener diodeFeatures1. High reliability2. Very sharp reverse characteristic3. Low reverse current level4. V Z-tolerance±5%ApplicationsVoltage stabilizationAbsolute Maximum RatingsT j=25?Parameter Test Conditions Type Symbol Value Unit Power dissipation T amb=50?P V 1 WZ-current I Z P V/V Z mA Junction temperature T j200 ? Storage temperature range T stg-65~+175 ?Maximum Thermal ResistanceT j=25?Parameter Test Conditions Symbol Value Unit Junction ambient I=9.5mm(3/8”) T L=constant R thJA 100 K/WElectrical CharacteristicsT j=25?Parameter Test Conditions Type Symbol Min Typ Max Unit Forward voltage I F=200mA V F 1.2 VV Znom1) I ZT for r zjT r zjK at I Z K I R at V R TypeV mA O O mA µA V DL4728A 3.3 76 <10 <400 1 <100 1 DL4729A 3.6 69 <10 <400 1 <100 1 DL4730A 3.9 64 <9 <400 1 <50 1 DL4731A 4.3 58 <9 <400 1 <10 1 DL4732A 4.7 53 <8 <500 1 <10 1 DL4733A 5.1 49 <7 <550 1 <10 1 DL4734A 5.6 45 <5 <600 1 <10 2 DL4735A 6.2 41 <2 <700 1 <10 3 DL4736A 6.8 37 <3.5 <700 1 <10 4 DL4737A 7.5 34 <4.0 <700 0. 5 <10 5 DL4738A 8.2 31 <4.5 <700 0. 5 <10 6 DL4739A 9.1 28 <5.0 <700 0. 5 <10 7 DL4740A 10 25 <7 <700 0.25 <10 7.6 DL4741A 11 23 <8 <700 0.25 <5 8.4 DL4742A 12 21 <9 <700 0.25 <5 9.1 DL4743A 13 19 <10 <700 0.25 <5 9.9 DL4744A 15 17 <14 <700 0.25 <5 11.4 DL4745A 16 15.5 <16 <700 0.25 <5 12.2 DL4746A 18 14 <20 <750 0.25 <5 13.7 DL4747A 20 12.5 <22 <750 0.25 <5 15.2 DL4748A 22 11.5 <23 <750 0.25 <5 16.7 DL4749A 24 10.5 <25 <750 0.25 <5 18.2 DL4750A 27 9.5 <35 <750 0.25 <5 20.6 DL4751A 30 8.5 <40 <1000 0.25 <5 22.8 DL4752A 33 7.5 <45 <1000 0.25 <5 25.1 DL4753A 36 7.0 <50 <1000 0.25 <5 27.4 DL4754A 39 6.5 <60 <1000 0.25 <5 29.7 DL4755A 43 6.0 <70 <1500 0.25 <5 32.7 DL4756A 47 5.5 <80 <1500 0.25 <5 35.8 DL4757A 51 5.0 <95 <1500 0.25 <5 38.8 DL4758A 56 4.5 <110 <2000 0.25 <5 42.6 DL4759A 62 4.0 <125 <2000 0.25 <5 47.1 DL4760A 68 3.7 <150 <2000 0.25 <5 51.7 DL4761A 75 3.3 <175 <2000 0.25 <5 561) Based on DC-measurement at thermal equilibrium while maintaining the lead temperature(T L)at 30?,9.5mm(3/8”) from the diode body.Dimensions in mm Standard Glass Case JEDEC LL 410.40.4 5.0±0.2 f 2.6±0.2f 2.8max。
74435561100;中文规格书,Datasheet资料
![74435561100;中文规格书,Datasheet资料](https://img.taocdn.com/s3/m/d74cfa00f12d2af90242e6c4.png)
74435561100
DATUM / DATE : 2009-11-02 Gurtspezifikation / Tape specification:
G H
SPEICHERDROSSEL WE-HCI POWER-CHOKE WE-HCI
I Rollenspezifikation / tape and reel specification:
74435561100
DATUM / DATE : 2009-11-02
SPEICHERDROSSEL WE-HCI POWER-CHOKE WE-HCI
H Induktivitätskurve / Inductance curve:
Induktivität vs Strom (typ.) Inductance vs Current (typ.)
08-09-29
Geprüft / checked
Kontrolliert / approved
Datum / date
D-74638 Waldenburg · Max-Eyth-Strasse 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400 http://www.we-online.de
12,00
10,00
8,00
L (µH)
6,00
4,00
2,00
0,00 0 5 10 15 Current (A) 20 25 30 35
Freigabe erteilt / general release:
..................................................................................
1955581资料
![1955581资料](https://img.taocdn.com/s3/m/4e58c2252af90242a895e55a.png)
Extract from the onlinecatalogCCV 2,5/ 8-G-5,08 P26THRR56Order No.: 1955581http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1955581Taped headers, pin length: 2.6 mm, tape width: 56 mm, 5.08 mm pitch, 8-pos.http://Please note that the data givenhere has been taken from theonline catalog. For comprehensiveinformation and data, please referto the user documentation. TheGeneral Terms and Conditions ofUse apply to Internet downloads. Technical dataDimensions / positionsPitch 5.08 mmDimension a35.56 mmNumber of positions8Pin dimensions 1 x 1 mmPin spacing 5.08 mmHole diameter 1.6 mmTechnical dataInsulating material group IIIaRated surge voltage (III/3) 4 kVRated surge voltage (III/2) 4 kVRated surge voltage (II/2) 4 kVRated voltage (III/2)320 VRated voltage (II/2)400 VConnection in acc. with standard EN-VDENominal current I N12 ANominal voltage U N250 VMaximum load current12 A (per position)Insulating material LCPInflammability class acc. to UL 94V0Certificates / ApprovalsApproval logoCULNominal voltage U N300 VNominal current I N10 AULNominal voltage U N300 VNominal current I N10 ACertification CUL, ULAccessoriesItem Designation DescriptionGeneral1954362CR-MSTB NAT HT HT coding section, is pushed into the recess on the header beforethe reflow process, made of highly temperature-resistant, beigeinsulating materialMarking1051993B-STIFT Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm0804303SK 5,08/3,8: 0-9Marker card, printed horizontally, self-adhesive, 10-section markerstrip, 12 identical decades marked 0-9, sufficient for 120 terminalblocks0804293SK 5,08/3,8:FORTL.ZAHLEN Marker card, printed horizontally, self-adhesive, 12 identicaldecades marked 1-10, 11-20 etc. up to 91-(99)100, sufficient for120 terminal blocks0805085SK 5,08/3,8:SO Marker card, special printing, self-adhesive, labeled acc. tocustomer requirements, 12 identical marker strips per card, max.25-position labeling per strip, color: white0805412SK 5,08/3,8:UNBEDRUCKT Marker cards, unprinted, with pitch divisions, self-adhesive, 10-section marker strips, 12 strips per card, can be labeled with theM-PENPlug/Adapter1734401CR-MSTB Coding section, inserted into the recess in the header or theinverted plug, red insulating materialDrawingsApplication drawingDrilling diagramDimensioned drawingBottom view, free space for solder paste, 0.55mm deepDirection of the arrow = feeding directionAddressPHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 Blomberg,GermanyPhone +49 5235 3 00Fax +49 5235 3 41200http://www.phoenixcontact.de© 2008 Phoenix ContactTechnical modifications reserved;。
1757255中文资料
![1757255中文资料](https://img.taocdn.com/s3/m/fce27b6c9b6648d7c1c7463f.png)
Extract from the onlinecatalogMSTBA 2,5/ 3-G-5,08Order No.: 1757255The figure shows a 10-position version of the producthttp://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1757255Header, nominal current: 12 A, rated voltage: 250 V, pitch: 5.08 mm, no. of positions: 3, mounting: Solderinghttp://Please note that the data givenhere has been taken from theonline catalog. For comprehensiveinformation and data, please referto the user documentation. TheGeneral Terms and Conditions ofUse apply to Internet downloads. Technical dataDimensions / positionsPitch 5.08 mmDimension a10.16 mmNumber of positions3Pin dimensions 1 x 1 mmHole diameter 1.4 mmTechnical dataInsulating material group IIIaRated surge voltage (III/3) 4 kVRated surge voltage (III/2) 4 kVRated surge voltage (II/2) 4 kVRated voltage (III/2)320 VRated voltage (II/2)400 VConnection in acc. with standard EN-VDENominal current I N12 ANominal voltage U N250 VMaximum load current12 AInsulating material PBTInflammability class acc. to UL 94V0Certificates / ApprovalsCSANominal voltage U N300 VNominal current I N10 ACULNominal voltage U N300 VNominal current I N10 AULNominal voltage U N300 VNominal current I N10 ACertification CB, CSA, CUL, GOST, UL, VDE-PZIAccessoriesItem Designation DescriptionAssembly1755477MSTB-BL Keying cap, for forming sections, plugs onto header pin, greeninsulating materialMarking1051993B-STIFT Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm0804293SK 5,08/3,8:FORTL.ZAHLEN Marker card, printed horizontally, self-adhesive, 12 identicaldecades marked 1-10, 11-20 etc. up to 91-(99)100, sufficient for120 terminal blocks0805085SK 5,08/3,8:SO Marker card, special printing, self-adhesive, labeled acc. tocustomer requirements, 12 identical marker strips per card, max.25-position labeling per strip, color: white0805412SK 5,08/3,8:UNBEDRUCKT Marker cards, unprinted, with pitch divisions, self-adhesive, 10-section marker strips, 12 strips per card, can be labeled with theM-PENPlug/Adapter1734401CR-MSTB Coding section, inserted into the recess in the header or theinverted plug, red insulating materialAdditional productsItem Designation DescriptionGeneral1872703A-ICV 2,5/ 3-G-5,08Header, nominal current: 12 A, rated voltage: 250 V, pitch: 5.08mm, no. of positions: 3, mounting: Mounting rail1873061FKC 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Spring-cage connection1902123FKCT 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Spring-cage connection1873964FKCVR 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Spring-cage connection1873663FKCVW 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Spring-cage connection1777293FRONT-MSTB 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1786417IC 2,5/ 3-G-5,08Header, nominal current: 12 A, rated voltage: 320 V, pitch: 5.08mm, number of positions: 3, mounting type: soldering1785955ICV 2,5/ 3-G-5,08Header, nominal current: 12 A, rated voltage: 320 V, pitch: 5.08mm, number of positions: 3, mounting type: soldering1757022MSTB 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1776168MSTB 2,5/ 3-STZ-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1808829MSTBC 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 320 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Crimpconnection1809514MSTBC 2,5/ 3-STZ-5,08Plug component, nominal current: 12 A, rated voltage: 320 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Crimpconnection1769023MSTBP 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1779990MSTBT 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1824366MSTBU 2,5/ 3-ST-5,08-FL Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1824133MSTBU 2,5/ 3-STD-5,08Plug component, nominal current: 12 A, rated voltage: 320 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1792252MVSTBR 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1792760MVSTBW 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1917914QC 0,75/ 3-ST-5,08Plug components, 5.08 mm pitch, color: green, no. of positions 3,dimension a 10.16 mm1883268QC 1/ 3-ST-5,08Plug, nominal current: 10 A, rated voltage: 500 V, pitch: 5.08mm, number of positions: 3, connection method: Insulationdisplacement connection QUICKON1826296SMSTB 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: Screwconnection1853023TMSTBP 2,5/ 3-ST-5,08Plug component, nominal current: 12 A, rated voltage: 250 V,pitch: 5.08 mm, no. of positions: 3, type of connection: ScrewconnectionDrawingsDrilling diagramDimensioned drawingAddressPHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 Blomberg,GermanyPhone +49 5235 3 00Fax +49 5235 3 41200http://www.phoenixcontact.de© 2008 Phoenix ContactTechnical modifications reserved;。
哈迪兰产品公司安全数据表说明书
![哈迪兰产品公司安全数据表说明书](https://img.taocdn.com/s3/m/96a01d49fd4ffe4733687e21af45b307e971f973.png)
HAVILAND PRODUCTS COMPANYSAFETY DATA SHEETSection 1: IdentificationProduct Name: Havaclean Hand Sanitizer-E Product Code:H006616Haviland Products Company 421 Ann Street NWGrand Rapids, MI 49504 (616) 361-6691Emergency Phone:CHEMTREC: Canada and USA - (800) 424-9300 CHEMTREC:In Mexico - 01-800-681-9531Product Use: Hand SanitizerNot recommended for: NASection 2: Hazard(s) IdentificationGHS Ratings:Flammable liquid2Skin corrosive3Eye corrosive2BOrgan toxin single exposure3Organ toxin repeated exposure 1Flash point < 23°C and initial boiling point > 35°C (95°F)Reversible adverse effects in dermal tissue, Draize score: >=1.5 <2.3Mild eye irritant: Subcategory 2B, Reversible in 7 daysTransient target organ effects- Narcotic effects- Respiratorytract irritationSignificant toxicity in humans- Reliable, good quality humancase studies or epidemiological studies Presumedsignificant toxicity in humans- Animal studies with significantand/or severe toxic effects relevant to humans at generallylow exposure (guidanc e)GHS HazardsH225Highly flammable liquid and vapour H316Causes mild skin irritationH320Causes eye irritationH335May cause respiratory irritationH336May cause drowsiness ordizzinessH372Causes damage to organsthrough prolonged or repeatedexposure GHS PrecautionsP210Keep away from heat/sparks/openflames/hot surfaces – No smokingP233Keep container tightly closedP240Ground/bond container and receivingequipmentP241Use explosion-proofelectrical/ventilating/light/equipmentP242Use only non-sparking toolsP243Take precautionary measures againststatic dischargeP260Do not breathedust/fume/gas/mist/vapors/sprayP261Avoid breathingdust/fume/gas/mist/vapors/sprayP264Wash face, hands, and any exposedskin thoroughly after handlingP270Do not eat, drink or smoke when usingthis productP271Use only outdoors or in a well-ventilatedareaPowered by Plymouth Technolog yP280Wear protective gloves/protective clothing/eye protection/face protection P312Call a POISON CENTER ordoctor/physician if you feel unwellP314Get Medical advice/attention if you feel unwellP303+P361+P353If on skin (or hair): Remove / Take off immediately all contaminated clothing. Rinse skin with water / shower.P304+P340If inhales: Remove victim to fresh air and keep at rest in a position comfortable for breathing.P305+P351+P338If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.P332+P313If skin irritation occurs: Get medical advice / attentionP337+P313If eye irritation persists get medical advice / attentionP370+P378In case of fire: Use suitable media for extinctionP405Store locked upP403+P233Store in a well-ventilated place. Keep container tightly closed.P403+P235Store in a well ventilated place. Keep coolP501Dispose of contents/container in accordance withlocal/regional/national/international regulationsDangerSection 3: Composition/Information on IngredientsChemical Name / CAS No.OSHA Exposure Limits ACGIH Exposure Limits Other Exposure LimitsEthyl alcohol 64-17-570% - 80%Vapor Pressure: 42.979 mmHg1000 ppm TWA; 1900 mg/m3 TWA1000 ppm STELNIOSH: 1000 ppmTWA; 1900 mg/m3 TWAGlycerin 56-81-51% - 5%Vapor Pressure: .002 mmHg15 mg/m3 TWA (mist, total particulate); 5 mg/m3 TWA (mist, respirable fraction)Hydrogen peroxide 7722-84-10.1% - 1.0%1 ppm TWA; 1.4 mg/m3 TWA1 ppm TWANIOSH: 1 ppm TWA; 1.4 mg/m3 TWASection 4: First-aid MeasuresInhalationRescuers should put on appropriate protective gear. Remove from area of exposure. If not breathing,give artificial respiration. If breathing is difficult, give oxygen. Keep victim warm. Get immediate medical attention. Toprevent aspiration, keep head below knees.Eye ContactImmediately flush eyes with water. Flush eyes with water for a minimum of 15 minutes, occasionallylifting and lowering upper lids. Get medical attention promptly.Skin ContactRemove contaminated clothing. Wash skin with soap and water. Get medical attention. Wash clothingseparately and clean shoes before reuse.IngestionIf swallowed, do NOT induce vomiting. Give victim a glass of water. Call a physician or poison control centerimmediately. Never give anything by mouth to an unconscious person.Section 5: Fire-fighting MeasuresExtinguishing MediaWater spray. Alcohol-resistant foam. BC powder. Carbon dioxide.Do not use: Solid water jet ineffective as extinguishing medium.Specific Hazards Arising from the ChemicalDIRECT FIRE HAZARD. Highly flammable. Gas/vapour flammable with air within explosion limits.INDIRECT FIRE HAZARD. May be ignited by sparks. Gas/vapour spreads at floor level:ignition hazard. Reactions involving a fire hazard: see "Reactivity Hazard".Explosion hazard : DIRECT EXPLOSION HAZARD. Gas/vapour explosive with air within explosion limits.INDIRECT EXPLOSION HAZARD. may be ignited by sparks. Reactions with explosion hazards:see "Reactivity Hazard".Special Protective Equipment and Precautions for FirefightersSpecial Information: As in any fire, wear self-contained breathing apparatus pressure-demand (MSHA / NIOSHapproved or equivalent) and full protective gear.Section 6: Accidental Release MeasuresSpill and Leak ProceduresRemove ignition sources. Use special care to avoid static electric charges. No naked lights. Nosmoking.Keep upwind. Mark the danger area. Consider evacuation. Seal off low-lying areas.Close doors and windows of adjacent premises. Stop engines and no smoking. No naked flamesor sparks.Spark- and explosion-proof appliances and lighting equipment. Keep containersclosed. Wash contaminated clothes.Clean up methods:Take up liquid spill into a non combustible material e .g.: sand, earth, vermiculite or powderedlimestone. Scoop absorbed substance into closing containers. See "Material-handling"forsuitable container materials. Carefully collect the spill/leftovers. Damaged/cooled tanks must beemptied. Do not use compressed air for pumping over spills. Clean contaminated surfaces withan excess of water. Take collected spill to manufacturer/competent authority . Wash clothing andequipment after handling.Section 7: Handling and StoragePrinted: 4/6/2020 at 2:51:41PMHandling ProceduresProper grounding procedures to avoid static electricity should be followed. Ground/bond container and receiving equipment. Use explosion-proofelectrical/ventilating/lighting/equipment.Use with adequate ventilation. Avoid breathing dusts, mists, and vapors. Do not get in eyes, on skin, or on clothing. Wear eye protection and protective clothing . Wash thoroughly after handling.Storage RequirementsKeep container tightly closed. Keep only in the original container in a cool, well ventilated place away from : incompatible materials. Keep in fireproof place.Incompatible products : Strong bases. Strong acids.Incompatible materials : Sources of ignition. Direct sunlight. Heat sources.Heat and ignition sources : KEEP SUBSTANCE AWAY FROM: heat sources. ignition sources.Prohibitions on mixed storage : KEEP SUBSTANCE AWAY FROM: oxidizing agents. (strong) acids. water/moisture.Storage area : Keep out of direct sunlight. Store in a dry area. Ventilation at floor level. Fireproof storeroom.Provide for an automatic sprinkler system. Provide for a tub to collect spills. Provide the tank with earthing. Meet the legal requirements.Special rules on packaging : SPECIAL REQUIREMENTS: closing. dry. clean. correctly labelled. meet the legal requirements.Secure fragile packagings in solid containers.Packaging materials : SUITABLE MATERIAL: stainless steel. aluminium. iron. copper. nickel. synthetic material. glass.Section 8: Exposure Control/Personal ProtectionOther Exposure LimitsACGIH Exposure Limits OSHA Exposure Limits Chemical Name / CAS No.1000 ppm TWA; 1900 mg/m3 TWA1000 ppm STELNIOSH: 1000 ppm TWA; 1900 mg/m3 TWAEthyl alcohol 64-17-515 mg/m3 TWA (mist, total particulate); 5 mg/m3 TWA (mist, respirable fraction)Glycerin 56-81-51 ppm TWA; 1.4 mg/m3 TWA1 ppm TWANIOSH: 1 ppm TWA; 1.4 mg/m3 TWAHydrogen peroxide 7722-84-1ENGINEERING CONTROLS: Provide ventilation sufficient to maintain exposure below the recommended limits.RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be followed whenever workplace conditions warrant the use of a respirator.SKIN PROTECTION: Wear impervious protective gloves. Wear protective gear as needed - apron, suit, boots. EYE PROTECTION: Wear safety glasses with side shields (or goggles) and a face shield.OTHER PROTECTIVE EQUIPMENT : Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower.HYGENIC PRACTICES: Do not eat, drink, or smoke in areas where this material is used. Avoid breathing vapors. Remove contaminated clothing and wash before reuse. Wash thoroughly after handling. Wash hands before eating.Section 9: Physical and Chemical PropertiesClear Colorless Liquid Appearance:AlcoholOdor:Not Available Vapor Pressure:Not AvailableOdor threshold:1.6Vapor Density: 6.5 - 8.5pH:Not AvailableDensity:Not AvailableMelting point:Not Available Freezing point:Complete Solubility:70° CBoiling range:25° C Flash point:8.3Evaporation rate (Ether=1):Not Available Flammability:Not AvailableExplosive Limits:0.837Specific Gravity Not AvailableAutoignition temperature:Not AvailableDecomposition temperature:Not Available Viscosity:Not AvailableGrams VOC less water:Section 10: Stability and Reactivity Chemical Stability:STABLEIncompatible MaterialsStrong acids. Strong bases.Conditions to AvoidDirect sunlight. Extremely high or low temperatures. Open flame.Hazardous Decomposition ProductsFume. Carbon monoxide. Carbon dioxide. May release flammable gases.Hazardous PolymerizationHazardous polymerization will not occur.Section 11: Toxicology InformationMixture ToxicityInhalation Toxicity LC50: 150mg/L Component Toxicity7722-84-1Hydrogen peroxideOral LD50: 801 mg/kg (Rat) Dermal LD50: 4,060 mg/kg (Rat) Inhalation LC50: 2 g/m3 (Rat)Routes of Entry:Inhalation Ingestion Skin contact Eye contactTarget OrgansBlood Eyes KidneysLiver Central Nervous System Reproductive System SkinRespiratory System Effects of OverexposureCarcinogen Rating CAS Number Description% Weight Hydrogen peroxide:7722-84-1Hydrogen peroxide 0.1% - 1.0%Section 12: Ecological InformationComponent Ecotoxicity Ethyl alcohol96 Hr LC50 Oncorhynchus mykiss: 12.0 - 16.0 mL/L [static]; 96 Hr LC50Pimephales promelas: >100 mg/L [static]; 96 Hr LC50 Pimephales promelas: 13400 - 15100 mg/L [flow-through]48 Hr LC50 Daphnia magna: 9268 - 14221 mg/L; 48 Hr EC50 Daphnia magna: 2 mg/L [Static]Glycerin96 Hr LC50 Oncorhynchus mykiss: 51 - 57 mL/L [static]Hydrogen peroxide96 Hr LC50 Pimephales promelas: 16.4 mg/L; 96 Hr LC50 Lepomis macrochirus:18 - 56 mg/L [static]; 96 Hr LC50 Oncorhynchus mykiss: 10.0 - 32.0 mg/L [static]48 Hr EC50 Daphnia magna: 18 - 32 mg/L [Static]Section 13: Disposal ConsiderationsDispose of in accordance with local, state and federal regulations.Section 14: Transportation InformationUN Code: 1993Proper Shipping Name: Flammable liquid, N.O.S. (Ethanol)Hazard Class: 3Packing Group: IIISection 15: Regulatory InformationOSHA Process Safety Management Highly Hazardous Chemicals7722-84-1 Hydrogen peroxideTSCA 8(b) Inventory7722-84-1 Hydrogen peroxide56-81-5 Glycerin64-17-5 Ethyl alcoholRegulationCountryAll Components ListedSection 16: Other InformationDate Prepared: 4/6/2020DisclaimerThe information herein is believed to be correct, but does not claim to be all inclusive and should beused only as a guide. Neither the above named supplier nor any of its affiliates or subsidiaries assumesany liability whatsoever for the accuracy or completeness of the information contained herein. Finaldetermination of suitability of any material is the sole responsibility of the user. All chemical reagentsmust be handled with the recognition that their chemical, physiological, toxicological, and hazardousproperties have not been fully investigated or determined. All chemical reagents should be handledonly by individuals who are familiar with their potential hazards and who have been fully trained in propersafety, laboratory, and chemical handling procedures. Although certain hazards are described herein,we can not guarantee that these are the only hazards which exist. Our SDS are based only on dataavailable at the time of shipping and are subject to change without notice as new information is obtained.Avoid long storage periods since the product is subject to degradation with age and may become moredangerous or hazardous. It is the responsibility of the user to request updated SDS for products that arestored for extended periods. Disposal of unused product must be undertaken by qualified personnelwho are knowledgeable in all applicable regulations and follow all pertinent safety precautions includingthe use of appropriate protective equipment (e.g. protective goggles, protective clothing, breathingequipment, face mask, fume hood). For proper handling and disposal, always comply with federal, stateand local regulations.。
IOS-MAT-0054_CNv5
![IOS-MAT-0054_CNv5](https://img.taocdn.com/s3/m/9ecec951ad02de80d4d84080.png)
参考
本技术规范中化学品要求和测试所引用的标准,如欧盟指令,都适用标准、指令的最新版本,除非 另有说明。
本资料仅供参考,英文版本 IOS-MAT-0054 具有最终法律效力。
1 of 23 2009-10-26 Elsa Hou 译稿
表2. 实木、木基材料和天然材料的要求
物质
要求
测试方法
文件
硼及其化合物
不允许使用硼及其化合物。
在实木(包括实木拼板)、 污染限值:硼及其化合物的迁移 天然纤维、胶合板、层压 值:30 mg 硼/kg 板/弯曲木中
如果木材有涂层,在 SD 测试前应去除涂层。
DIN 53160(用人工 合成汗液进行萃取, 16小时,23 °C), 然后依照EN ISO 11885(ICP/AES分 析)
IOS-MAT-0054 第五版译文
原版本代号:
审稿人:Jason Liu, Teresa Xu, Sebrina Chen
AA-92520-5 2009-10-09
化合物和化学物质:对儿童产品与玩具的附加要求
内容
本规范阐述了宜家对所有儿童产品(包括玩具)的化合物和化学物质的附加要求。
关于此规范
本规范的目的是确保儿童产品和玩具在儿童使用时是安全的,因为儿童更为敏感,并且接触产品的 方式与成人不同(如吮吸和咀嚼)。
染料
不允许使用。
在印刷或上色的纸/纸板中 污染限值:每种染料10 mg/kg
甲醛(50-00-0)
甲醛含量不可高于30mg/kg。 EN 71-11
文件 SD
SD
2.3 纺织品
表4.对纺织品的要求
API 7K 第5版中文版
![API 7K 第5版中文版](https://img.taocdn.com/s3/m/4b296a0ac5da50e2524d7f96.png)
7.7质量控制要求...................................................................15
8.2 质量控制人员资格...............................................................16
8.3测试设备.......................................................................16
5设计验证..........................................................................8
5.1总则............................................................................8
7焊接要求.........................................................................15
7.1总则...........................................................................15
9.7 活塞泥浆泵零部件...............................................................31
9.8绞车零部件.....................................................................55
AS1554.1-2004 Amdt-01-2005
![AS1554.1-2004 Amdt-01-2005](https://img.taocdn.com/s3/m/dff2e5010740be1e650e9af2.png)
ISBN 0 7337 6450 9AS/NZS 1554.1/Amdt 1/2005-01-20STANDARDS AUSTRALIA/STANDARDS NEW ZEALANDAmendment No. 1toAS/NZS 1554.1:2004 Structural steel weldingPart 1: Welding of steel structuresCORRECTIONThe 2004 edition of AS/NZS 1554.1 is amended as follows; the amendment(s) should b e inserted in the appropriate place(s).SUMMARY: This Amendment applies to the Preface, Clause 1.1, Table 4.7.1, Appendix A and Appendix E. Published on 20 January 2005.Approved for pub lication in New Zealand on b ehalf of the Standards Council of New Zealand on 26 November 2004.Page 2 PrefaceAdd the following paragraph after the second paragraph:‘This edition incorporates the following major changes to the 2000 edition: (a)Amendments to the following Clauses :1.6(a)(i), 1.6(a)(ii), 1.6(b)(i), 1.6(b)(ii), 1.6(b)(iii), 1.7 (new NOTE), 1.8.2 (NOTE deleted), 1.8.3 (new Clause),2.1 (last paragraph and NOTE), 2.3.4, 3.3.1 (first paragraph),4.1.2 (first sentence), 4.3, 4.4(c), 4.5.5.1 (second paragraph), 4.5.5.3, 4.6.1.1, 4.7.1 (NOTE 1 deleted), 4.7.9 (second paragraph), 4.7.10 (second sentence), 4.11 (new NOTE), 4.12.1, 4.12.2(f)(ii), 4.12.2 (NOTE 2), 5.1.1 (last two sentences), 5.2.2 (second paragraph), 5.3.3, 5.8.1 (new NOTE), 5.8.4 (new NOTE), 7.2, B3.3, B4.2 (first paragraph), Appendix D (new Item (n)). (b)Amendments to the following Tables :3.3.5 (Title),4.7.1, 4.11(A) (Items (b), (c), (e) and (k)), 4.12.2 (NOTE 2),5.3.4(A), C2, E1 (drawings for joints B-C 8a and B-C 8b), E4 (new joints H-C 1c and H-C 1d). (c)Amendments to the following Figures :3.4.1(c), 4.5.5.2 (new), 4.5.5.3 (NOTES), 5.3.4(A).’Page 5 Clause 1.1Redesignate ‘Items (a) to (f)’ to read as ‘Items (a) to (g)’ respectively (7 items).AMDT No. 1 JAN 2005AMDT No. 1 JAN 2005L i c e n s e d t o M r P a u l F D o n o v a n o n 09 J u n 2005. 1 u s e r p e r s o n a l u s e r l i c e n c e o n l y . S t o r a g e , d i s t r i b u t i o n o r u s e o n n e t w o r k p r o h i b i t e d .Page 37 Table 4.7.1Amend the title of the last two columns under ‘Fillet welds ’ to read as follows:Fillet weldsHardness Macro (see Clause 4.7.4)HAZ in accordance with Note 2(seeClause 4.7.9)Page 71 Appendix A1 Line 1, amend heading ‘AN/NZS ISO ’ to read as ‘AS/NZS ISO ’. 2Lines 3 and 4, amend Standard Numbers ‘3484-1 and 3484-2’ to read as ‘3834-1 and3834-2’ respectively.Page 87 Table E1In 2nd column for ‘Joint identification B-C3’ delete ‘)(αto )(βr r F t F t −−’ and replace with the ‘()()r r 31to 32F t F t −⋅’.Page 93 Table E2Delete the drawing for ‘Joint identification B-P 4a, C-P 4, T-P 4’ and replace with the following drawing:Page 101 Table E4Delete row for ‘Joint identification H-C 2c ’ and replace with the following:AMDT No. 1 JAN 2005AMDT No. 1 JAN 2005AMDT No. 1 JAN 2005AMDT No. 1 JAN 2005AMDT No. 1 JAN 2005L i c e n s e d t o M r P a u l F D o n o v a n o n 09 J u n 2005. 1 u s e r p e r s o n a l u s e r l i c e n c e o n l y . S t o r a g e , d i s t r i b u t i o n o r u s e o n n e t w o r k p r o h i b i t e d .L i c e n s e d t o M r P a u l F D o n o v a n o n 09 J u n 2005. 1 u s e r p e r s o n a l u s e r l i c e n c e o n l y . S t o r a g e , d i s t r i b u t i o n o r u s e o n n e t w o r k p r o h i b i t e d .。
7427155;中文规格书,Datasheet资料
![7427155;中文规格书,Datasheet资料](https://img.taocdn.com/s3/m/ef7de2f87c1cfad6195fa7a1.png)
6.1 6.0 5.02012-06-272012-04-302007-01-25SStSStSMuSStSMu-Würth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyTel. +49 (0) 79 42 945 - 0A Dimensions: [mm]Additional FeaturesSafety key to lock/ unkock74271D2 General Properties:Ferrite core Ferrite core Ferrite core Plastic housing Plastic housing Test cable Test cablePropertiesMaterial Initial permeability Curie temperatureColourFlammability ClassificationApplicable cable Applicable cable lengthµi T CValue 4 W 620620150Grey UL94-V0AWG26120Unit°Cmm Tol.typ.typ.F Typical Impedance Characteristics:I Cautions and Warnings:The following conditions apply to all goods within the product series of WE-STAR RINGof Würth Elektronik eiSos GmbH & Co. KG:General:All recommendations according to the general technical specifications of the data sheet have to be complied with.The disposal and operation of the product within ambient conditions which probably alloy or harm the component surface has to be avoided.The packaging of the product is to encase the needed humidity of the plastic housing. To ensure the humidity level, the products have to be stored in this delivered packaging. If not, the products are losing their humidity. In this case you can re-condition the components according to the internal standard WE1883 to ensure the necessary humidity in the plastic.To ensure the operating mode of the product, the ambient temperature at processing (when the part will be mounted on the cable) has to be in the range of 15 to 25 °C.Before mounting, the part should be stored for one hour in this condition.The responsibility for the applicability of customer specific products and the use in a particular customer design is always within the authority of the customer. All technical specifications for standard products do also apply for customer specific products.Direct mechanical impact to the product and the forcible closing of this shall be prevented as the ferrite material of the ferrite body or the pla-stic housing could flake or in the worst case it could break.Product specific:Follow all instructions mentioned in the datasheet, especially:•The cable diameter must be pointed out, otherwise no warranty will be sustained.•Violation of the technical product specifications such as exceeding the nominal rated current will result in the loss of warranty.1. General Customer ResponsibilitySome goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the are-as, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The responsibi-lity for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product characteristics described in the product specification is valid and suitable for the respective customer application or not.2. Customer Responsibility related to Specific, in particular Safety-Relevant ApplicationsIt has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime can-not be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component.3. Best Care and AttentionAny product-specific notes, warnings and cautions must be strictly observed.4. Customer Support for Product SpecificationsSome products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve spe-cific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales person in charge should be contacted who will be happy to support in this matter.5. Product R&DDue to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the customer as per Secti-on 1 and 2 remains unaffected.6. Product Life CycleDue to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a stan-dard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product availability ex-pectancy before or when the product for application design-in disposal is considered.The approach named above does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.7. Property RightsAll the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth Elektronik eiSos GmbH & Co. KG.8. General Terms and ConditionsUnless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth Elektronik eiSos Group”, last version available at .J Important Notes:The following conditions apply to all goods within the product range of Würth Elektronik eiSos GmbH & Co. KG:分销商库存信息: WURTH-ELECTRONICS 7427155。
产品标识584安全数据表说明书
![产品标识584安全数据表说明书](https://img.taocdn.com/s3/m/b65211c3a1116c175f0e7cd184254b35eefd1a87.png)
1.1. Product identifierProduct Identity 584Alternate Names 64052000, 640520011.2. Relevant identified uses of the substance or mixture and uses advised against Intended use See Technical Data Sheet. Application Method See Technical Data Sheet. 1.3. Details of the supplier of the safety data sheetCompany Name John Tillman Company1300 W. Artesia Blvd.Compton, CA 90220. USA Emergency24 hour Emergency Telephone No. 310-764-0110Customer Service: 310-764-01102.1. Classification of the substance or mixtureEye Irrit. 2;H319 May cause eye irritation.2.2. Label elementsUsing the Toxicity Data listed in section 11 and 12 the product is labeled as follows.WarningH319 May cause eye irritation.[Prevention]:P264 Wash thoroughly after handling.P280 Wear protective gloves / eye protection / face protection.[Response]:P305+351+338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.P337+313 If eye irritation persists: Get medical advice / attention.[Storage]:No GHS storage statements[Disposal]:No GHS disposal statementsThis product contains the following substances that present a hazard within the meaning of the relevant State and Federal Hazardous Substances regulations.In accordance with paragraph (i) of §1910.1200, the specific chemical identity and/or exact percentage (concentration) of composition has been withheld as a trade secret.[1] Substance classified with a health or environmental hazard.[2] Substance with a workplace exposure limit.[3] PBT-substance or vPvB-substance.*The full texts of the phrases are shown in Section 16.4.1. Description of first aid measuresGeneral In all cases of doubt, or when symptoms persist, seek medical attention.Never give anything by mouth to an unconscious person.Inhalation Remove to fresh air; drink water to clear throat and blow nose to expel fibers.Eyes Irrigate copiously with clean water for at least 15 minutes, holding the eyelids apart and seek medical attention.Skin Remove contaminated clothing. Wash skin thoroughly with soap and water or use arecognized skin cleanser.Ingestion Not available4.2. Most important symptoms and effects, both acute and delayedOverview Signs and Symptoms of Exposure: Skin, eyes, and respiratory tract irritation.Generally aggravated by exposure: any condition generally aggravated by mechanicalirritants in air or on skin.See section 2 for further details.Eyes May cause eye irritation.5.1. Extinguishing mediaWater, carbon dioxide, or dry chemical.5.2. Special hazards arising from the substance or mixtureHazardous decomposition: Carbon dioxide and carbon monoxide5.3. Advice for fire-fightersUnusual Fire Explosion Hazards: None.Thermal decomposition of fiber coating may produce an irritating mixture of smoke and fumes. Fire fighters should wear full protective gear including NIOSH approved self-contained breathing apparatus.ERG Guide No. ----6.1. Personal precautions, protective equipment and emergency proceduresPut on appropriate personal protective equipment (see section 8).6.2. Environmental precautionsDo not allow spills to enter drains or waterways.Use good personal hygiene practices. Wash hands before eating, drinking, smoking or using toilet. Promptly remove soiled clothing and wash thoroughly before reuse.6.3. Methods and material for containment and cleaning upSteps to be taken in case material is released or spilled:Prevent the spread of fiberglass dust and avoid dust generation conditions. Those involved in the cleanup of particulates should use appropriate personal protective equipment. Vacuum clean dusts. If sweeping is necessary, use a dust suppressant.Waste Disposal Method:In most cases, woven fiberglass scrap can be disposed of in a sanitary landfill in accordance with federal, state, and local regulations. Check with authorities on any question concerning disposal.Store and use in manner that will prevent airborne particulates in the workplace.7.1. Precautions for safe handlingSee section 2 for further details. - [Prevention]:7.2. Conditions for safe storage, including any incompatibilitiesHandle containers carefully to prevent damage and spillage.Incompatible materials: Avoid contact with strong oxidizing agents.See section 2 for further details. - [Storage]:7.3. Specific end use(s)No data available.8.1. Control parametersCarcinogen Data8.2. Exposure controlsRespiratory Where dust levels exceed the TLV, use NIOSH approved respirator to protect against nuisance dusts.Eyes Chemical Goggles, or Safety glasses with side shieldsSkin Work aprons or smocks are recommended. Wear loose fitting long sleeved clothing.NIOSH approved air supplies or self-contained respirator. Protective gloves and barriercream are necessary.Engineering Controls Local Exhaust: Recommended for processing machinery where dust generation isapparent.Mechanical (General): Yes, where local exhaust ventilation is not feasible.Other Work Practices Wash thoroughly after work. For non-routine & emergency situations, we recommend laundering work clothes separately and wiping out the washer at the end of every cycle.Use good personal hygiene practices. Wash hands before eating, drinking, smoking orusing toilet. Promptly remove soiled clothing and wash thoroughly before reuse.See section 2 for further details. - [Prevention]:Appearance Light Tan or White FabricOdor Not MeasuredOdor threshold Not determinedpH Not MeasuredMelting point / freezing point > 1000FInitial boiling point and boiling range Not MeasuredFlash Point (Method Used): 250% C by TOC Evaporation rate (Ether = 1) Not MeasuredFlammability (solid, gas) Not ApplicableUpper/lower flammability or explosive limits Lower Explosive Limit: Not MeasuredUpper Explosive Limit: Not Measured Vapor pressure (Pa) Not MeasuredVapor Density Not MeasuredSpecific Gravity (H2O=1): 2.5Solubility in Water Not MeasuredPartition coefficient n-octanol/water (Log Kow) Not MeasuredAuto-ignition temperature Not MeasuredDecomposition temperature Not MeasuredViscosity (cSt) Not Measured9.2. Other informationNo other relevant information.10.1. ReactivityHazardous Polymerization will not occur.10.2. Chemical stabilityStable under normal circumstances.10.3. Possibility of hazardous reactionsNo data available.10.4. Conditions to avoidNo data available.10.5. Incompatible materialsAvoid contact with strong oxidizing agents.10.6. Hazardous decomposition productsCarbon dioxide and carbon monoxideAcute toxicityNote: When no route specific LD50 data is available for an acute toxin, the converted acute toxicity point estimate was used in the calculation of the product's ATE (Acute Toxicity Estimate).12.1. ToxicityNo additional information provided for this product. See Section 3 for chemical specific data.Aquatic Ecotoxicity12.2. Persistence and degradabilityThere is no data available on the preparation itself.12.3. Bioaccumulative potentialNot Measured12.4. Mobility in soilNo data available.12.5. Results of PBT and vPvB assessmentThis product contains no PBT/vPvB chemicals.12.6. Other adverse effectsNo data available.13.1. Waste treatment methodsObserve all federal, state and local regulations when disposing of this substance.DOT (Domestic Surface Transportation) IMO / IMDG (OceanTransportation)ICAO/IATA14.1. UN number Not Applicable Not Regulated Not Regulated 14.2. UN proper shippingnameNot Regulated Not Regulated Not Regulated14.3. Transport hazard class(es) DOT Hazard Class: NotApplicableIMDG: Not ApplicableSub Class: Not ApplicableAir Class: Not Applicable14.4. Packing group Not Applicable Not Applicable Not Applicable 14.5. Environmental hazardsIMDG Marine Pollutant: No14.6. Special precautions for userNo further informationRegulatory Overview The regulatory data in Section 15 is not intended to be all-inclusive, only selected regulations are represented.Toxic Substance Control Act ( TSCA) All components of this material are either listed or exempt from listing on the TSCA Inventory. WHMIS Classification D2BUS EPA Tier II Hazards Fire: NoSudden Release of Pressure: NoReactive: NoImmediate (Acute): YesDelayed (Chronic): NoEPCRA 311/312 Chemicals and RQs:To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. EPCRA 302 Extremely Hazardous:To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. EPCRA 313 Toxic Chemicals:To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. Proposition 65 - Carcinogens (>0.0%):To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. Proposition 65 - Developmental Toxins (>0.0%):To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. Proposition 65 - Female Repro Toxins (>0.0%):To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. Proposition 65 - Male Repro Toxins (>0.0%):To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. New Jersey RTK Substances (>1%) :To the best of our knowledge, there are no chemicals at levels which require reporting under this statute. Pennsylvania RTK Substances (>1%) :To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.The information and recommendations contained herein are based upon data believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. We accept no responsibility and disclaim all liability for any harmful effects which may be caused by exposure to our products. Customers/users of this product must comply with all applicable health and safety laws, regulations, and orders.The full text of the phrases appearing in section 3 is:H319 May cause eye irritation.End of Document。
p65 list linked 中文版
![p65 list linked 中文版](https://img.taocdn.com/s3/m/5aba9f0df18583d0496459ac.png)
化学品
Type of Toxicity(毒 性的类型) cancer developmental, female, male cancer cancer developmental cancer developmental cancer cancer cancer developmental, male cancer
Arsenic (inorganic arsenic compounds) Arsenic (inorganic oxides) Asbestos
三氧化二砷 砒霜 三氧化二砷 砒霜 石绵瘤
cancer developmental cancer
-3-
Chemical Aspirin (NOTE: It is especially important not to use aspirin during the last three months of pregnancy, unless specifically directed to do so by a physician because it may cause problems in the unborn child or complications during delivery.) Atenolol Atrazine Auramine Auranofin Avermectin B1 (Abamectin) Azacitidine Azaserine Azathioprine Azathioprine Azobenzene Barbiturates Beclomethasone dipropionate Benomyl Benthiavalicarb-isopropyl Benz[a]anthracene Benzene Benzene Benzidine [and its salts] Benzidine-based dyes Benzodiazepines Benzo[b]fluoranthene Benzo[j]fluoranthene Benzo[k]fluoranthene Benzofuran Benzophenone Benzo[a]pyrene Benzotrichloride Benzphetamine hydrochloride Benzyl chloride Benzyl violet 4B Beryllium and beryllium compounds Beryllium Beryllium oxide Beryllium sulfate Betel quid with tobacco
5804中文资料
![5804中文资料](https://img.taocdn.com/s3/m/ec1950dadb38376baf1ffc4ffe4733687e21fcc1.png)
5804中⽂资料Combining low-power CMOS logic with high-current and high-voltage bipolar outputs, the UCN5804B and UCN5804LB BiMOS II translator/drivers provide complete control and drive for a four-phase unipolar stepper-motor with continuous output current ratings to 1.25 A per phase (1.5 A startup) and 35 V.The CMOS logic section provides the sequencing logic, DIRECTION and OUTPUT ENABLE control, and a power-on reset function. Three stepper-motor drive formats, wave-drive (one-phase), two-phase, and half-step are externally selectable. The inputs are compatible with standard CMOS, PMOS, and NMOS circuits. TTL or LSTTL may require the use of appropriate pull-up resistors to ensure a proper input-logic high.The wave-drive format consists of energizing one motor phase at a time in an A-B-C-D (or D-C-B-A) sequence. This excitation mode consumes the least power and assures positional accuracy regardless of any winding inbalance in the motor. Two-phase drive energizes two adjacent phases in each detent position (AB-BC-CD-DA). This sequence mode offers animproved torque-speed product, greater detent torque, and is less susceptible to motor resonance. Half-step excitation alternates between the one-phase and two-phase modes (A-AB-B-BC-C-CD-D-DA), providing an eight-step sequence.The bipolar outputs are capable of sinking up to 1.5 A and withstanding 50 V in the off state (sustaining voltages up to 35 V). Ground-clamp and flyback diodes provide protection against inductive transients. Thermal protection circuitry disables the outputs when the chip temperature is exces-sive.Both devices are rated for operation over the temperature range of -20°C to +85°C. The UCN5804B is supplied in a 16-pin dual in-line plastic batwing package with a copper lead frame and heat-sinkable tabs for improved power dissipation capabilities; the UCN5804LB is supplied in a 16-lead plastic SOIC batwing package with a copper lead frame and heat-sinkable tabs.FEATURESI 1.5 A Maximum Output Current I 35 V Output Sustaining VoltageI Wave-Drive, Two-Phase, and Half-Step Drive Formats I Internal Clamp DiodesI Output Enable and Direction Control I Power-On ResetI Internal Thermal Shutdown CircuitryBiMOS II UNIPOLARSTEPPER-MOTOR TRANSLATOR/DRIVERAlways order by complete part number, e.g., UCN5804B .Data Sheet 26184.12C*5804115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-********BiMOS II UNIPOLAR STEPPER-MOTORTRANSLATOR/DRIVERTRUTH TABLEDrive Format Pin 9Pin 10Two-Phase L L One-Phase H L Half-Step L H Step-InhibitHHTYPICAL INPUT CIRCUITDwg. EP-021-4TYPICAL OUTPUT DRIVERDwg. EP-010-5INCopyright ? 1987, 2000 Allegro MicroSystems, Inc.5075100125150510A L L O W A B L E P A C K A G E P O W E R D I S S I P A T I O N I N W A T T STEMPERATURE IN °C43225Dwg. GP-049-2A5804BiMOS II UNIPOLAR STEPPER-MOTOR TRANSLATOR/DRIVER/doc/a3712eddb9f3f90f76c61b7c.htmlELECTRICAL CHARACTERISTICS at T A = 25°C, T J ≤ 150°C, V DD = 4.5 V to 5.5 V (unless otherwise noted). Limits CharacteristicSymbol Test Conditions Min.Typ.Max.Units Output Leakage Current I CEX V OUT = 50 V—1050µA Output Sustaining Voltage V CE(sus)I OUT = 1.25 A, L = 3 mH 35——V Output Saturation VoltageV CE(SAT)I OUT = 700 mA — 1.0 1.2V I OUT = 1 A — 1.1 1.4V I OUT= 1.25 A— 1.2 1.5V Clamp Diode Leakage Current I R V R = 50 V —1050µA Clamp Diode Forward Voltage V F I F = 1.25 A — 1.53.0V Input CurrentI IN(1)V IN = V DD —0.5 5.0µA I IN(0)V IN = 0.8 V —-0.5-5.0µA Input VoltageV IN(1)V DD = 5 V3.5— 5.3V V IN(0)-0.3—0.8V Supply Current I DD 2 Outputs ON—2030mA Turn-Off Delay t ON 50% Step Inputs to 50% Output ——10µs Turn-On Delayt OFF 50% Step Inputs to 50% Output ——10µs Thermal Shutdown TemperatureT J—165—°CTIMING CONDITIONSA. Minimum Data Set Up Time . . . . . . . . . . . . . . . . . . . . . . . . 100 nsB. Minimum Data Hold Time . . . . . . . . . . . . . . . . . . . . . . . . . . 100 nsC. Minimum Step Input Pulse Width . . . . . . . . . . . . . . . . . . . . . 3.0 µsDwg. W-110AONE PHASE HALF STEPOOUTPUT ENABLEOUTPUT C OUTPUT DCLOCK115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-50005804BiMOS II UNIPOLAR STEPPER-MOTORTRANSLATOR/DRIVERWAVE-DRIVE SEQUENCEHalf Step = L, One Phase = H Step A B C D POR ON OFF OFF OFF 1ON OFF OFF OFF 2OFF ON OFF OFF 3OFF OFF ON OFF 4OFFOFFOFFONTWO-PHASE DRIVE SEQUENCEHalf Step = L, One Phase = LStep A B C D POR ON OFF OFF ON 1ON OFF OFF ON 2ON ON OFF OFF 3OFF ON ON OFF 4OFFOFFONONHALF-STEP DRIVE SEQUENCEHalf Step = H, One Phase = LStep A B C D POR ON OFF OFF OFF 1ON OFF OFF OFF 2ON ON OFF OFF 3OFF ON OFF OFF 4OFF ON ON OFF 5OFF OFF ON OFF 6OFF OFF ON ON 7OFF OFF OFF ON 8ONOFFOFFONAPPLICATIONS INFORMATIONInternal power-on reset (POR) circuitry resets OUTPUT A (and OUTPUT D in the two-phase drive format) to the on state with initial applica-tion of the logic supply voltage. After reset, the circuit then steps according to the tables.The outputs will advance one sequenceposition on the high-to-low transition of the STEP INPUT pulse. Logic levels on the HALF-STEP and ONE-PHASE inputs will determine the drive format (one-phase, two-phase, or half-step). The DIRECTION pin determines the rotation se-quence of the outputs. Note that the STEP INPUT must be in the low state when changing the state of ONE-PHASE, HALF-STEP, or DIRECTION to prevent erroneous stepping.All outputs are disabled (off) when OUTPUT ENABLE is at a logic high. If the function is not required, OUTPUT ENABLE should be tied low.In that condition, all outputs depend only on the state of the step logic.During normal commutation of a unipolar stepper motor, mutual coupling between the motor windings can force the outputs of the UCN5804B below ground. This condition will cause forward biasing of the collector-to-substrate junction and source current from the output. For many L/R applications, this substrate current is high enough to adversely affect the logic circuitry and cause misstepping. External series diodes (Schottky are recommended for increasedefficiency at low-voltage operation) will prevent substrate current from being sourced through the outputs. Alternatively, external ground clamp diodes will provide a preferred current path from ground when the outputs are pulled below ground.Internal thermal protection circuitry disables all outputs when the junction temperature reaches approximately 165°C. The outputs are enabled again when the junction cools down to approxi-mately 145°C.5804BiMOS II UNIPOLAR STEPPER-MOTOR TRANSLATOR/DRIVER/doc/a3712eddb9f3f90f76c61b7c.htmlTYPICAL APPLICATION L/R Stepper-Motor DriveThe products described here are manufactured under one or more U.S. patents or U.S. patents pending.Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may berequired to permit improvements in the performance, reliability, or manufacturability of its products. Before placing an order, the user is cautioned to verify that the information being relied upon is current.Allegro products are not authorized for use as critical components in life-support devices or systems without express written approval.The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsi-bility for its use; nor for any infringement of patents or other rights of third parties which may result from its use.115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-50005804BiMOS II UNIPOLAR STEPPER-MOTORTRANSLATOR/DRIVERUCN5804BDimensions in Inches (controlling dimensions)Dimensions in Millimeters(for reference only)NOTES:1.Exact body and lead configuration at vendor’s option within limits shown.2.Lead spacing tolerance is non-cumulative.3.Lead thickness is measured at seating plane or below.4.Webbed lead frame. Leads 4, 5, 12, and 13 are internally one piece.5.Supplied in standard sticks/tubes of 25 devices.Dwg. MA-001-17A in18Dwg. MA-001-17A mm185804 BiMOS II UNIPOLAR STEPPER-MOTOR TRANSLATOR/DRIVER/doc/a3712eddb9f3f90f76c61b7c.htmlUCN5804LB(add “TR” to part number for tape and reel) Dimensions in Inches(for reference only)Dimensions in Millimeters(controlling dimensions)NOTES:1.Exact body and lead configuration at vendor’s option within limits shown.2.Lead spacing tolerance is non-cumulative.3.Lead thickness is measured at seating plane or below.4.Webbed lead frame. Leads 4, 5, 12, and 13 are internally one piece.5.Supplied in standard sticks/tubes of 47 devices or add “TR” to part number for tape and reel.115 Northeast Cutoff, Box 15036Worcester, Massachusetts 01615-0036 (508) 853-50005804BiMOS II UNIPOLAR STEPPER-MOTORTRANSLATOR/DRIVERMOTOR DRIVERSFunctionOutput Ratings*Part Number ?INTEGRATED CIRCUITS FOR BRUSHLESS DC MOTORS3-Phase Power MOSFET Controller —28 V 39333-Phase Power MOSFET Controller —50 V 39323-Phase Power MOSFET Controller —50 V 76002-Phase Hall-Effect Sensor/Driver 400 mA 26 V 3626Bidirectional 3-Phase Back-EMFController/Driver ±600 mA 14 V 89062-Phase Hall-Effect Sensor/Driver 900 mA 14 V 36253-Phase Back-EMFController/Driver ±900 mA 14 V 8902–A 3-Phase Controller/Drivers ±2.0 A 45 V 2936 & 2936-120INTEGRATED BRIDGE DRIVERS FOR DC AND BIPOLAR STEPPER MOTORSDual Full Bridge with Protection & Diagnostics ±500 mA 30 V 3976PWM Current-Controlled Dual Full Bridge ±650 mA 30 V 3966PWM Current-Controlled Dual Full Bridge ±650 mA 30 V 3968PWM Current-Controlled Dual Full Bridge ±750 mA 45 V 2916PWM Current-Controlled Dual Full Bridge ±750 mA 45 V 2919PWM Current-Controlled Dual Full Bridge ±750 mA 45 V 6219PWM Current-Controlled Dual Full Bridge ±800 mA 33 V 3964PWM Current-Controlled Full Bridge ±1.3 A 50 V3953PWM Current-Controlled Dual Full Bridge ±1.5 A 45 V 2917PWM Current-Controlled Microstepping Full Bridge ±1.5 A 50 V 3955PWM Current-Controlled Microstepping Full Bridge ±1.5 A 50 V 3957PWM Current-Controlled Dual DMOS Full Bridge ±1.5 A 50 V 3972Dual Full-Bridge Driver ±2.0 A 50 V 2998PWM Current-Controlled Full Bridge ±2.0 A 50 V3952DMOS Full Bridge PWM Driver ±2.0 A 50 V 3958Dual DMOS Full Bridge ±2.5 A 50 V 3971UNIPOLAR STEPPER MOTOR & OTHER DRIVERSVoice-Coil Motor Driver ±500 mA 6 V 8932–A Voice-Coil Motor Driver ±800 mA 16 V 8958Unipolar Stepper-Motor Quad Drivers 1 A 46 V 7024 & 7029Unipolar Microstepper-Motor Quad Driver 1.2 A 46 V 7042Unipolar Stepper-Motor Translator/Driver 1.25 A 50 V 5804Unipolar Stepper-Motor Quad Driver 1.8 A 50 V 2540Unipolar Stepper-Motor Quad Driver 1.8 A 50 V 2544Unipolar Stepper-Motor Quad Driver 3 A 46 V 7026Unipolar Microstepper-Motor Quad Driver 3 A 46 V 7044*Current is maximum specified test condition, voltage is maximum rating. See specification for sustaining voltage limits or over-current protection voltage limits. Negative current is defined as coming out of (sourcing) the output.?Complete part number includes additional characters to indicate operating temperature range and package style.Also, see 3175, 3177, 3235, and 3275 Hall-effect sensors for use with brushless dc motors.。
74157中文资料
![74157中文资料](https://img.taocdn.com/s3/m/694e5a8ebceb19e8b8f6baa4.png)
TL F 655054157 DM54157 DM74157 Quad 2-Line to 1-Line Data Selectors MultiplexersJune1989 54157 DM54157 DM74157Quad2-Line to1-Line Data Selectors MultiplexersGeneral DescriptionThese data selectors multiplexers contain inverters anddrivers to supply full on-chip data selection to the four out-put gates A separate strobe input is provided A4-bit wordis selected from one of two sources and is routed to the fouroutputsApplicationsY Expand any data input pointY Multiplex dual data busesY Generate four functions of two variables(one variableis common)Y Source programmable countersFeaturesY Buffered inputs and outputsY Typical propagation time9nsY Typical power dissipation150mWY Alternate Military Aerospace device(54157)is avail-able Contact a National Semiconductor Sales OfficeDistributor for specificationsConnection DiagramDual-In-Line PackageTL F 6550–1Order Number54157DMQB 54157FMQB DM54157J DM54157W or DM74157NSee NS Package Number J16A N16E or W16AFunction TableInputsOutput YStrobe Select A BH X X X LL L L X LL L H X HL H X L LL H X H HH e High Level L e Low Level X e Don’t CareC1995National Semiconductor Corporation RRD-B30M105 Printed in U S AAbsolute Maximum Ratings(Note)If Military Aerospace specified devices are required please contact the National Semiconductor Sales Office Distributors for availability and specifications Supply Voltage7V Input Voltage5 5V Operating Free Air Temperature RangeDM54and54b55 C to a125 C DM740 C to a70 C Storage Temperature Range b65 C to a150 C Note The‘‘Absolute Maximum Ratings’’are those values beyond which the safety of the device cannot be guaran-teed The device should not be operated at these limits The parametric values defined in the‘‘Electrical Characteristics’’table are not guaranteed at the absolute maximum ratings The‘‘Recommended Operating Conditions’’table will define the conditions for actual device operationRecommended Operating ConditionsSymbol ParameterDM54157DM74157Units Min Nom Max Min Nom MaxV CC Supply Voltage4 555 54 7555 25V V IH High Level Input Voltage22V V IL Low Level Input Voltage0 80 8V I OH High Level Output Current b0 8b0 8mA I OL Low Level Output Current1616mA T A Free Air Operating Temperature b55125070 CElectrical Characteristics over recommended operating free air temperature range(unless otherwise noted)Symbol Parameter Conditions MinTypMax Units (Note1)V I Input Clamp Voltage V CC e Min I I e b12mA b1 5VV OH High Level Output V CC e Min I OH e Max2 43 4VVoltage V IL e Max V IH e MinV OL Low Level Output V CC e Min I OL e Max0 4VVoltage V IH e Min V IL e MaxI I Input Current Max V CC e Max V I e5 5V1mA Input VoltageI IH High Level Input Current V CC e Max V I e2 4V40m AI IL Low Level Input Current V CC e Max V I e0 4V b1 6mAI OS Short Circuit V CC e Max DM54b20b55mA Output Current(Note2)DM74b18b55I CC Supply Current V CC e Max(Note3)3048mA Note1 All typicals are at V CC e5V T A e25 CNote2 Not more than one output should be shorted at a timeNote3 I CC is measured with4 5V applied to all inputs and all outputs open2Switching Characteristics at V CC e5V and T A e25 C(See Section1for Test Waveforms and Output Load)Symbol Parameter From(Input)R L e400X C L e15pFUnits To(Output)Min Maxt PLH Propagation Delay Time Data14ns Low to High Level Output to Yt PHL Propagation Delay Time Data14ns High to Low Level Output to Yt PLH Propagation Delay Time Strobe20ns Low to High Level Output to Yt PHL Propagation Delay Time Strobe21ns High to Low Level Output to Yt PLH Propagation Delay Time Select23ns Low to High Level Output to Yt PHL Propagation Delay Time Select27ns High to Low Level Output to YLogic Diagram157TL F 6550–234Physical Dimensions inches(millimeters)16-Lead Ceramic Dual-In-Line Package(J)Order Number54157W or DM54157JNS Package Number J16A16-Lead Molded Dual-In-Line Package(N)Order Number DM74157NNS Package Number N16E554157 D M 54157 D M 74157Q u a d 2-L i n e t o 1-L i n e D a t a S e l e c t o r s M u l t i p l e x e r sPhysical Dimensions inches (millimeters)(Continued)16-Lead Ceramic Flat Package (W)Order Number 54157FMQB or DM54157WNS Package Number W16ALIFE SUPPORT POLICYNATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION As used herein 1 Life support devices or systems are devices or 2 A critical component is any component of a life systems which (a)are intended for surgical implant support device or system whose failure to perform can into the body or (b)support or sustain life and whose be reasonably expected to cause the failure of the life failure to perform when properly used in accordance support device or system or to affect its safety or with instructions for use provided in the labeling can effectivenessbe reasonably expected to result in a significant injury to the userNational Semiconductor National Semiconductor National Semiconductor National Semiconductor CorporationEuropeHong Kong LtdJapan Ltd1111West Bardin RoadFax (a 49)0-180-530858613th Floor Straight Block Tel 81-043-299-2309。
TL957 2004 中译文
![TL957 2004 中译文](https://img.taocdn.com/s3/m/8769f01b14791711cc79178d.png)
硅玻璃汽车窗玻璃质量要求TL-957 (2004)描述:硅玻璃、汽车玻璃、玻璃文件申述期限:截止于2004年4月30日使用范围警示注释:由于正在草拟中的标准可能和该技术文本存在不一致的地方,在原则上不可以根据草拟中的标准进行加工。
如果在个别的情况下采用草拟中的标准,那么使用双方应当对此进行协商约定。
目录内容页码1 使用范围 (2)2 标识 (2)3 名称 (2)3.1 名称缩写 (2)4 要求 (3)4.1 法规要求 (3)4.2 备查义务 (3)4.3 官方结构类型批准 (3)4.4 试样 (3)4.5 标记(玻璃图章) (4)4.6 供货 (4)5 划伤和其它一般缺陷 (4)5.1 检验方法 (5)6 几何尺寸要求 (5)7 愿材料要求 (5)7.1 粘接性能要求 (5)7.2 耐候性能 (6)7.3 光学要求 (6)7.4 耐光性 (6)7.5 耐湿性 (6)7.6 煮沸试验 (6)7.7 红外线反射玻璃的抗腐蚀性 (6)8 机械性能要求 (7)8.1 钢化安全玻璃 (7)8.2 夹层安全玻璃(部分予应力)夹层安全玻璃 (8)9 光学要求 (9)9.1 浮法结构.......................…………………………………………………………….................... .99.2 玻璃面定位................…………………………………………………………........................... .99.3 偏移误差 (9)9.4 带加热丝玻璃的透光性能 (10)9.5 风挡玻璃透射性能 (11)9.6 颜色印刷 (11)9.7 丝网印刷光学缺陷 (12)9.8 侧窗玻璃反射波纹 (13)10 特殊要求 (13)10.2 夹层安全玻璃 (13)10.3 部分予应力玻璃 (14)10.4 钢化玻璃 (14)11 检验方法 (14)11.1光学检验方法 (15)12 试验设备 (16)12.1落球试验紧围框...........………………………………………………………...........................12.2散弹袋................…………………………………………………………….............................12.3钢箭试验...............…………………………………………………………..............................13 相关标准 (16)附件A.......................……………………………………………………………....…......................附件B..................…………………………………………………………….…..............................附件C.............…………………………………………………………….......….............................更改:与TL957-2002标准相比,有如下更改:增加9.3.1条修改附录C旧版1966-10;1968-07;1970-05;1975-06;1981-11;1982-09;1984-09;1985-07;1985-11;1986-08;1987-01;1988-03;1988-06;1989-07;1993-07;1999-02;2000-06;2000-09;2001-11;2002-101 使用范围本标准制定了对汽车硅玻璃的要求和检验.2 标识例如对前风挡硅玻璃质量要求标识为:玻璃质量按照TL9573 名称3.1 名称缩写WSS 挡风玻璃RWS 车厢后窗玻璃KS 手摇车窗玻璃SS 车厢侧窗玻璃DSS 三角玻璃Schwerk. 重力扭曲Pressb. 压力带扭曲Bespatt. 污损的Besp. 污损TSA+ 玻璃种类名称QB 汽车纵向轴的横向扭曲ESG 单层安全玻璃4 要求4.1 法规要求本供货技术条件是图纸要求的一部分,以图纸要求为准。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
5-177851-4 Product Details
Home | Customer Support | Suppliers | Site Map | Privacy Policy | Browser Support
© 2008 Tyco Electronics Corporation All Rights Reserved Search
Products Documentation Resources My Account Customer Support Home > Products > By Type > Product Feature Selector > Product Details
5-177851-4
Preliminary 1.25mm Centerline F-P (Fine Pitch
Connectors)
Always EU RoHS/ELV Compliant (Statement of Compliance)
Product Highlights:
?Header Type = Receptacle
?PCB Mount Style = Surface Mount
?Vertical Mount Angle
?Number of Rows = Dual
?Number of Positions = 24
View all Features | Find Similar
Products
Check Pricing &
Availability
Search for Tooling
Product Feature
Selector
Contact Us About
This Product
Quick Links
Documentation & Additional Information
Product Drawings:
?ON TAPING (EMBOSS) 1.25 F-P CONNECTOR (B-TO-B) Au P...
(PDF, English)
Catalog Pages/Data Sheets:
?None Available
Product Specifications:
?AMP 1.25mm F-P Connector (Board To Board)(PDF, Japanese) Application Specifications:
?None Available
Instruction Sheets:
?None Available
CAD Files:
?None Available
List all Documents Additional Information:
?Product Line Information
Related Products:
?Tooling
Product Features (Please use the Product Drawing for all design activity)
Product Type Features:
?PCB Mount Style = Surface Mount
?Mount Angle = Vertical
?Number of Positions = 24
?PCB Retention Feature = Yes
?Polarization = With
?Product Type = Header
Body Related Features:
?Header Type = Receptacle
?Number of Rows = Dual
?PCB Retention Method = Hold Down Post
?Polarization Method = Short Rib
?Centerline (mm [in]) = 1.25 [0.049]
Contact Related Features:
?Contact Mating Area Plating = DURAGOLD (20)
over Nickel
?Contact Material = Phosphor Bronze Housing Related Features:
?Housing Material = PPS
?Housing Color = Black
?Housing Flammability Rating = UL 94V-0
Industry Standards:
?RoHS/ELV Compliance = RoHS compliant, ELV
compliant
?Lead Free Solder Processes = Reflow solder
capable to 245°C
?RoHS/ELV Compliance History = Always was
RoHS compliant
Packaging Related Features:
?Packaging Method = Reel
?Packaging Quantity = 1,000
Other:
?Brand = AMP
Provide Website Feedback | Contact Customer Support。