SGG+Cool-lite+SKN+II资料下载-200810614917765

合集下载

深圳市科特翎科技有限公司产品规格书说明书

深圳市科特翎科技有限公司产品规格书说明书

产品规格书SPECIFICATION产品名称N ame.NO:0805白光White产品型号Model.NO:KTR-0805CWD文件编号Document.NO:MQ8032版次REV.NO:K3.0描述Description:■ 2.0×1.25mm贴片发光二极管2.0×1.25mm Chip SMD ■胶体颜色Colloid Color:黄色Yellow■发光颜色Emission Color:白色White■半功率角度Viewing Angle:120°深圳市科特翎科技有限公司SHENZHEN KETERINE TECHNOLOGY CO.,LTD.编制Prepared by审核Checked by核准Approved by市场部Market Dept.客户确认CUSTOMER CONFIRMATION确认Confirmed by审核Checked by核准Approved by确认Confirmed by1.外形尺寸Dimensions单位(Units):毫米(mm)注意:所有尺寸单位为mm,如无特殊说明误差范围为±0.1mmAll dimensions area in mm tolerance is±0.1mm unless otherwise noted.2.光电特性Electrical/Optical characteristics (1)最大限度值Absolute Maximum Ratings(TA=25±5ºC)项目Item符号Symbol最大额定值Absolute Maximum Rating单位Unit正向电流Forward Current IF20mA正向峰值电流Pulse Forward Current IFP100mA反向电压Reverse Voltage VR5V功率消耗Power Dissipation PD70mW工作温度Operating Temperature Topr-40ºC To+85ºC°C贮藏温度Storage Temperature Tstg-40ºC To+85ºC°C焊接温度Soldering Temperature Tsld ReflowSoldering:260ºC For10sec. 1/10周期,0.1msec脉宽IFP Conditions:1/10Duty Cycle,0.1msec Pulse Width.(2)样品光电参数Initial Electrical/Optical Characteristics(TA=25±5ºC)符号Symbol 项目Item单位Units最小值Min.规格值Typ.最大值Max.测试条件TestConditionsVF正向电压Forward Voltage V 2.6 3.2IF=10mAIR反向电流Reverse Current uA10VR=7V2θ½发光角度Viewing Angleº120ºIF=10mAø发光强度Luminous Intensitymcd6001080IF=10mATC色温Colour Temperature k700011000IF=10mARA显色指数Color Rendering Index Ra7080IF=10mA 正向电压允许误差±0.05V Tolerance of measurement of Vf is±0.05V.亮度允许误差±10%Luminous Intensity Measurement allowance is±10%.3.特性曲线Characteristic curve4.可靠性RELIABILITY (1)测试项目及结果Test Items and Results实验项目Test Items 参考标准Reference实验条件Test Conditions时间Time样品数Quantity判据Criterion冷热冲击Thermal Shock MIL-STD-202G-40℃(30min)←→100℃(30min)循环200次200cycles220/22湿热循环Temperature And Humidity Cyclic JEITA ED-4701200203-10℃——+65℃,0%-90%RH24hrs./1cycle循环10次10cycles220/22高温储存High Temperature Storage JEITA ED-4701200201Ta=100℃1000h220/22低温储存Low Temperature Storage JEITA ED-4701200202Ta=-40℃1000h220/22高温高湿储存High Temperature High Humidity Storage JEITA ED-4701100103Ta=60℃,RH=90%1000h220/22常温寿命试验Life Test JESD22-A108D Ta=25℃IF=20mA1000h220/22高温寿命High Temperature Life Test JESD22-A108D Ta=80℃IF=20mA1000h220/22低温寿命Low Temperature Life Test JESD22-A108D Ta=-40℃IF=20mA1000h220/22耐焊接热Resistance to Soldering Heat GB/T4937,Ⅱ,2.2&2.3Tsol*=260℃10secs.2次2times220/225.注意事项Cautions(1)焊接条件Soldering Conditions本产品最多只可回焊两次,且在首次回焊后须冷却至室温之后方可进行第二次回焊。

SGGCOOL-LITEKTseries-crystal…

SGGCOOL-LITEKTseries-crystal…

SGGCOOL-LITE KT seriesSGG COOL-LITE KTSGG COOL-LITE KT combines Solar Control, low-Emissivity,Selectivity and possibility of heat treatment (can be tempered).Only to be used in DGU(Double Glazing Unit) or in laminatedglass, coating facing the PVB.Exists in Neutral colour (SGG COOL-LITE KNT) or in Blue colour in reflection (SGG COOL-LITE KBT)Be careful! Coating must only be applied on surface #2, andabove all, coatings must be edge stripped (removed at theedges) prior to assembly in DGU or laminated glass.SGG COOL-LITE KTSGG COOL-LITE KNT & KBT coatings :Are selectiveAre low-E coatingsCan only be used with coating on surface # 2Must be assembled into DGUMust be edge strippedCannot be used as single glazingCan be temperedCan be laminatedCan be enamelledCan be curvedSolar Control Coated Glass -OFF-Line Coatings SGGCOOL-LITE KTFour temperable coatings combining Solar Control and low-E performance, rather neutral colour (or blue for KBT) and low-reflectivity.LTLR Eg U ColorSelec-tivity SGG COOL-LITE KNT 16458140.45 1.4Neutral Neutral Neutral Blue1.29SGG COOL-LITE KNT 15548170.37 1.4 1.30SGG COOL-LITE KNT 14036220.27 1.3 1.33SGG COOL-LITE KBT 14036240.301.31.20DGU : 6 KT 1xx + 16 argon + 6 clear -Solar control coating #2Performances of SGG COOL-LITE KT deposited on SGG PLANILUXSolar Control Coated Glass -OFF-Line Coatings SGG COOL-LITE KT on clear : Graph LT –g-value010203040506070010203040506070Factor solar, g (%)ST167ST150KNT164KNT155ST136STB136STB120ST120ST108KNT140KBT140SGGCOOL-LITE STSGGCOOL-LITE KTSGGCOOL-LITE SKNSGGCOOL-LITE XTREME SGGCOOL-LITE E II ET 125SGG COOL-LITE KT on green glassDGU : 6 KT 4xx + 16 argon + 6 clear -Solar control coating #2Performances of SGG COOL-LITE KT deposited on SGG PARSOL GREENLTLR E g U ColorSelec-tivity SGG COOL-LITE KNT 46447110.30 1.4Green Green Green1.57SGG COOL-LITE KNT 45539130.25 1.4 1.56SGG COOL-LITE KNT 44030170.211.31.43SGG COOL-LITE KT on blue glassDGU : 6 KT 7xx + 16 argon + 6 clear -Solar control coating #2Performances of SGG COOL-LITE KT deposited on SGG PARSOL BLUELTLR E g U ColorSelec-tivity SGG COOL-LITE KNT 7643780.29 1.4Blue Blue Blue1.28SGG COOL-LITE KNT 75531100.24 1.4 1.29SGG COOL-LITE KNT 74024120.201.31.20Solar Control Coated Glass-OFF-Line Coatings SGG COOL-LITE ReminderSolar Control coatings OFF-line coatingsSGG COOL-LITESGG COOL-LITE STSGG COOL-LITE KTSolar ControlLow-ESelective4 coatings10 productsNeutral&colorsTemperableEasy tohandle,stock &processUse in DGU orinside laminatedglassSolar ControlLow to mediumselectivity7 coatings21 productsNeutral&colorsTemperableEasy to handle,stock & processUse asmonolithic,IGU,laminated,curvedSGG COOL-LITE E IISolar ControlLow-ELow selective1 coating3 productsNeutral&colors‘to betempered’Easy toprocessUse as singleglazing or in DGU。

FlashLite SQiY

FlashLite SQiY

・ミクシー ・モバゲー ・グリー

ゲームの作成法提案
Flash Lite ゲーム を作るスタイルの 提示がキーポイント
Flash Lite サイズ制限ゲーム開発費今までと Nhomakorabea異なる商品
・ソーシャルゲーム業社向け ・手離れの良い製品 ・低額商品→農耕的販売 ・コピー可能→広く配布
・100kb の壁 ・部品全ては盛り込めない ・シナリオ別部品合成が必須
swfmill
GPL2
/
ming
LGPL
/
・SWF を作成するための様々な API を備え、各言語へのバインディング が多い点は有利だが、SWF 合成に特化した API ではない→ API を 用いて合成エンジンを自らコーディングしなくてはならない。
Flash Lite 合成エンジン(SQiY)開発資料
2010/04/27 version 1.7
Flash Lite 合成エンジン(SQiY)開発資料
Page 1
Confidential
Created By i-BROADCAST Inc.
Flash Lite 合成エンジン(SQiY)開発資料 ソーシャルゲーム市場に対する新製品
2010/04/27 version 1.7
価格:高
snapVu
snaprec FF
snaprec FL 既存製品
SQiY for FLV
アプライアンスサーバー製品
FF beam
SQiY for CMS
サーバープラグイン製品
CMS プラグイン製品
価格:低
SQiY
無料/デスクトップ製品
ソーシャルゲーム向け製品
・対戦戦車ゲームにおける自軍戦車を肖像画オブジェクトで置換したサンプル

LG G2 Getting Started说明书

LG G2 Getting Started说明书

Getting StartedP/NO : MFL67006501(1.0)Green features of this manualGreen features of this manualENGLISH ESPAÑOLMicrophonell screen shots in this guide are simulated. Actual displays may vary.nstructions to perform tasks in this guide are based on the default phone settings and may change depending on the software version on your phone.Caps/Shift Key o enter capitalo lock the Caps/ Shift key, pressT o unlock it, press the key Vibrate Key • P ress the Alt key and then this key to switch to vibrate mode.Lock T ouch KeyDuring setup you will be asked to sign into your existing Google account. If you do not have a Google account you can create one.If you are an existing Gmail TM user, all of your Gmail, Google contacts and Google Calendar events will begin to automatically sync to your phone.Location IndicatorThe dots indicate which Home screen pane you are viewing.ouch and hold Home screen pane Location indicator to viewHome screen pane thumbnails. T ouch one to open it.Home Screen ThumbnailsNOTE: LG Home screen pane location is indicated by the dots at the top of the Launch icon. To return to the center Home paneouch the Launch icon ( or ).ouch an icon toopen an applicationyou’ve used recently.N OTE: T o turn this feature on and off, from the Home screen, press the Menu Key and touch Settings > Sound & display > then, select/deselect Orientation .Rotate the phone counter-clockwise for landscape orientation.Rotate the phone clockwise for portrait orientation.icon on the Home screen or inouch the number touch keys to enter the phone number.to look up another contact in the Contacts list. While using other applications, the phone icon will appear in the Status bar as long as theto adjust the callbutton to the right.If you were already on a call, the first call is placed onhold while you answer the new call.button to the left.The caller is sent directly to your voicemail box to leaveicon on the Home screen or in the Launch screen.or touch and holdso you can enter numbers.ollow the setup tutorial.elect a password.ecord a voice signature and greetings for your Voice Mailbox.icon on the Home screen or in the Launch screen.or touch and holdicon on the Home screen..and follow the on screenrom the Home screen, open the Launch screen by touching or .icon .If you need to enter email account settings the wizard can’t configure for you, touch nter a name for the account and the name you want to be displayed on outgoing messages, then touch Done. Yyour inbox will be displayed.elect the type of email account. (If the account type is unknown, check with your email provider. POP3 is the most common.)Incoming server settings, then touchOutgoing server settings, then touchHome screen, touch the Voice Search iconNOTE: In some applications, such as Gmail, Contacts, and Browser, the application’s own search box opens when you touch thefeature to the Quick Search Box, touch theyou’re working in, touching theF rom the Home screen, press the >>icon on the Home screen or in the Launch ou may not be able to zoom in/out on webpages designed for mobile devices.F rame your subject on screen and touch the Shutter icon to take the picture.T ouch the Gallery icon to view your image gallery.T ouch the picture to open it.T ouch Menu > Share.T ouch the application you want to use to share the selected picture. The application you selected opens with the picture (or a link) attached. Follow the instructions to complete sharing.icon . icon , then press the。

GTCOOL培训教程V62

GTCOOL培训教程V62

GTCOOL培训教程V62一、引言GTCOOL培训教程V62是一款针对我国高校及科研院所推出的专业计算流体力学(CFD)软件教程。

本教程旨在帮助用户掌握GTCOOL软件的基本操作、模型构建、网格划分、求解器设置、结果分析与后处理等方面的技能,以便在科研和工程领域高效地解决流体力学问题。

本教程共分为五个部分,分别为:软件概述、前处理、求解器设置、后处理和案例分析。

二、软件概述1.全面的物理模型:GTCOOL软件内置了丰富的湍流模型、燃烧模型、多相流模型等,可满足用户在不同场景下的计算需求。

2.高效的求解器:GTCOOL采用先进的大规模并行计算技术,可充分利用高性能计算资源,提高计算效率。

3.灵活的网格划分:GTCOOL支持多种网格划分方法,如结构网格、非结构网格和混合网格等,满足不同场景的计算需求。

4.强大的后处理功能:GTCOOL提供丰富的数据可视化手段,如矢量图、等值线图、流线图等,方便用户对计算结果进行分析。

5.易用的界面:GTCOOL采用图形化操作界面,降低了软件的使用门槛,使初学者能够快速上手。

三、前处理前处理是CFD计算过程中至关重要的一环,主要包括几何建模、网格划分和边界条件设置等。

本节将详细介绍GTCOOL软件的前处理功能。

1.几何建模:GTCOOL支持导入CAD软件的几何模型,如STEP、IGES等格式。

用户还可以通过软件内置的几何建模工具进行模型的构建和修改。

2.网格划分:GTCOOL支持多种网格划分方法,如结构网格、非结构网格和混合网格等。

用户可以根据计算需求选择合适的网格类型,并通过软件提供的网格划分工具进行网格的和优化。

3.边界条件设置:GTCOOL提供了丰富的边界条件设置选项,如速度入口、压力出口、壁面等。

用户可以根据实际计算场景设置相应的边界条件。

四、求解器设置求解器设置是CFD计算过程中的核心环节,主要包括物理模型选择、数值方法和求解器参数设置等。

本节将详细介绍GTCOOL软件的求解器设置功能。

Singtel 2Gbps Learn+Work Bundle 商品说明书

Singtel 2Gbps Learn+Work Bundle 商品说明书

2Gbps Learn+Work BundleEnjoy Fastest Speeds on Two Dedicated WiFi Networks with 2Gbps Fibre Frequently Asked Questions1.How does a 2Gbps network work?Our 2Gbps asymmetric bandwidth allows for a maximum download speed of 2Gbps and amaximum upload speed of 1Gbps on our GPON Optical Network Router (ONR). The ONR has4 available active Gbe LAN ports that can each transmit at a maximum speed of 1Gbps toyour Singtel Mesh Extender, third party router / access point, or Internet-enabled devices(e.g. computer, Smart TV) via a wired connection.2.What is included in the 2Gbps Learn+Work Bundle?To power you through Home Based Learning and Working From Home, the 2GbpsLearn+Work Bundle comes with 2Gbps Fibre Broadband with WiFi devices to give you twofast and dedicated WiFi networks. The WiFi networks are achieved through a pair of Mesh Extenders to help extend your WiFi coverage and a Linksys E9450 Wi-Fi 6 router to give you fastest WiFi speeds.3.The bundle comes with a pair of Mesh Extenders and a Linksys WiFi 6 Router. Do they worktogether in a mesh network?These devices are meant to create 2 separate WiFi networks to cater to your family’s needs and bandwidth requirements. They do not work together to create a single mesh network.Select which WiFi network best suits your needs (extended coverage vs fastest speeds) orchoose to allocate separate networks for various family members. Achieve faster WiFispeeds without all your WiFi devices crammed onto one network. It’s like a second internet highway just opened up for you.4.What does it mean by 2 separate WiFi networks?The Mesh Extenders and the Linksys E9450 creates separate WiFi networks for you to log in and use. Since these works independently and does not share bandwidth, it enables fasterspeeds for you and your family.5.What is the speed achieved for each network?The Optical Network Router (ONR) given with your 2Gbps plan has 4 available connections, each giving up to 1Gbps speed. Combined, the 4 ports enable a concurrent downloadbandwidth of up to 2Gbps. The WiFi devices (Mesh Exenders and Linksys Router) given with this 2Gbps Learn+Work Bundle connect separately to the ONR and enables a maximum1Gbps bandwidth to be maximised on two ports, giving you better 2 Gbps speed in yourhome. This is much faster than all your devices pointing to just one WiFi mesh/Routerconnected to one port.6.Why is Linksys in Bridge (AP) mode and not in RG mode?The Linksys E9450 is connected to the Optimal Network Router (ONR) which is already arouter. Hence, to ensure that the Linksys E9450 doesn’t interfere wit h the ONR’s settings, Singapore Telecommunications Limitedthe Linksys should be configured in Bridge mode. Also, the Linksys E9450 router will only be compatible with Singtel TV in Bridge mode.A Singtel Technician will help you to set up your devices when you first sign up for thisLearn+Work Bundle. However, you can refer to these guides also if you need to set upyourself:-Guide for setting up your Linksys E9450:https:///sg/support-article?articleNum=317681#ONT-Guide for setting up your Linksys E9450 using the Setup Wizard:https:///sg/support-article/?articleNum=3174727.Can I connect Singtel TV to the Linksys E9450?Yes, you can connect your Singtel TV Set up box to the Linksys E9450. Note that Linksys can connect to one Singtel TV set up box only. You can also connect your Singtel TV Set up box directly into the ONR.8.I am an existing Singtel Fibre customer and would like to recontract to the 2GbpsLearn+Work Bundle. Can I do so?If you would like to recontract your Singtel Fibre Broadband plan, the current recontractpolicy will apply. Hence, you may recontract your price plan anytime if you meet theminimum contract term (according to the Recontract Eligibility Policy). You may recontract toa same / higher speed price plan between from the 21st to 24th month of your contractperiod. If you have fulfilled the full 24 months of your existing contract, you may recontract to this bundle at any time.Singapore Telecommunications Limited。

Coolius 1000 自动空调维修机说明书

Coolius 1000 自动空调维修机说明书

User manual for Automatic A/C-Service Unit Coolius 1000Identification:Manufactory: WIGAMLoc.Spedale 10/b52018 Castel San Niccolò(Arezzo) ItalyTel. +39 0575 5011Fax. +39 0575 501200*************Distributed: Würth Online World GmbHSchliffenstr./Falkhof74653 KünzelsauProduct: Automatic A/C-Service UnitTyp: WOW! Coolius 1000Product No: 0900 764 981Directives:2006/42/EEC Machines directive2004/108/EEC Directive on elctromagnetic compatibility2006/95/EEC Directive on low voltageIEC 34-11 (EN 60034) General standards on single phase electric, rotative machinesIEC 335-1 Safety on electrical devices in domestic applicationWürth Online World! GmbH Künzelsau reserves the right to discontinue, or change at any time specifications or designs without notice and without incurring obligations according to her policy of always improving her products.IndexIdentification: (1)Layout drawing (3)Hydraulic diagram (5)Electric diagram (6)Legend (7)Safety precautions (8)1Introduction to recovery unit COOLIUS-1000 (9)1.1TECHNICAL SPECIFICATIONS (9)1.2Control module (10)2Preparing unit COOLIUS-1000 for use (11)2.1Checking the vacuum pump oil level (11)2.2TURNING COOLIUS-1000 ON (11)2.3“ZERO” SCALE CHECK (11)2.4Filling refrigerant into the internal bottle (11)3Using COOLIUS-1000 unit (13)3.1Refrigerant recovery (13)3.2Vacuum + Vacuum Test (14)3.3Oil / Uv - Refrigerant (14)3.4Automatic cycle (15)3.5Flushing (17)3.6Checking A/C system operating pressures (17)3.7Disconnecting the unit from the A/C system (18)3.8Setting Menu (18)4Accessories and spare parts (19)5Dimensions and weight (19)Support (20)LegendSafety precautionsThis equipment is designed for trained personnel only, who must know the refrigeration fundamentals, cooling systems, refrigerants and possible damage that pressurized equipment may cause.Carefully read the instructions contained in this manual; strict observance of the procedures described is fundamental to the operator’s safety, the perfect state of the unit and constant performances as declared. The unit must always work under the operator’s direct supervisionDo not operate the unit with different refrigerant than the one it has been designed for.Before performing any operation, make sure that the hoses used for connections have been previously evacuated and that they do not contain non-condensable gases.Avoid skin contact; the low boiling temperature of the refrigerant (about -30°C) can cause freezing.Avoid breathing refrigerant vapours.It is recommended to wear suitable protections like safety glasses and gloves; contact with refrigerant may cause blindness and other personal injuries.Do not operate near open flames and hot surfaces; the high temperatures decompose the refrigerant releasing toxic and caustic substances which are hazardous for the operator and the environment.Always make sure that the unit is connected to a suitably protected mains supply provided with an efficient earth connection.Before performing maintenance operations or when the unit will not be used for a long period of time, turn the unit off by turning the main switch to 0 and disconnect the power supply cord; absolutely follow the sequence of operations.Operate the unit only in locations with suitable ventilation and a high number of air changes.Before disconnecting the unit, make sure that the cycle has been completed and that all valves are closed in order to avoid release of refrigerant to the atmosphere.Never fill any tank with liquid refrigerant to more than 75% of its maximum capacity.During operations avoid release of refrigerant to the environment; this precaution is required by international environmental standards and is essential to avoid difficult leak detection in a refrigerant polluted environment.The equipment must always work under the operator’s control.Protect the unit from dripping.Do not modify the calibration of safety valves and control systems.If you recover refrigerant from a cooling system equipped with a water evaporator and/or condenser, it is necessary to drain water from the evaporator and/or condenser or to keep the circulation pump running during the entire recovery operation in order to avoid frosting.1Introduction to recovery unit COOLIUS-1000COOLIUS-1000 unit permits quick and efficient recovery of refrigerant from the A/C system, refrigerant recycling, system evacuation, check for tightness, additive or lubricant injection, the subsequent charge with refrigerant and measurement of the operating pressures.1.1TECHNICAL SPECIFICATIONSModel .......................................................... COOLIUS-1000Refrigerant (134)Maximum storage capacity ........................... 10 kgMaximum recovery rate ................................ 0,3 kg/minPower supply ................................................ 230/1/50Power input .................................................. 500 WStorage temperature ..................................... -10 ÷ +50 °CWorking temperature .................................... 0 ÷ 40 °CDegree of protection ..................................... IP24Noise level ................................................... < 70dB (A)Refrigerant max charge ................................ 9 kg1.2 UNIT’S COMPONENTSComponent FeatureCompressor 6 cc. recovery rate 0,3 kg/minVacuum pump Rotary vane type and single stage, 100 l/minFilter direr Dehydrating capacity of 75 PPM of waterFlexible hoses L=3 meters with quick couplersFan Axial type and high flow rateRefrigerant bottle Capacity of 10 kg with liquid and vapour connectionsDistiller – Separator High heat exchange distillation chamber withautomatic flow controlBottle for discharged oil Capacity of 200 grams of oil, on load cellBottle for oil charge Capacity of 200 grams of oil, on load cellControl module Fast access keys to the functions1.2Control moduleRecovery Access to the Refrigerant Recovery functionVacuum Access to the Vacuum functionCharge Access to the oil/refrigerant charging functionMenu/ExitAutoStart/StopUp/DownRecovery functionVacuum functionOil Charge /Refrigerant chargefunctionMenu functionExit keyAuto function Start/ Stop keyUP arrowDOWN arrow2Preparing unit COOLIUS-1000 for use2.1Checking the vacuum pump oil levelBefore checking the oil level, the unit must be placed on a level surface and its power supply must be turned off.The user must check that the vacuum pump oil level covers half of the sight glass (see drawing below)and the hardware version. Wait a few seconds in order to see the standby screen. By means of theUP/DOWN arrows, it is possible to shift to the second standby screen2.3“ZERO” SCALE CHECK1.Make sure that the unit refrigerant bottle is empty2.Wait at least 5 minutes so that the bottle/scale assembly stabilizes before proceeding; in case the values ofscales are not equal to 0, perform the procedure by following the below steps; otherwise go to section 2.4.3.Proceed to the unit initial reset before the first use4.Press the MENU key5.Select Service by means of the UP / DOWN arrows.6.Confirm by pressing the START key7.Press the following keys in succession: Vacuum, Charge, Down, Up8.When coming back to the Standby screen, all the scales will be placed on the value 0.2.4Filling refrigerant into the internal bottle1.Place the bottle containing refrigerant so that liquid refrigerant will come out (bottle with tube upright,bottle without tube upside down)2.Connect the 53 hose to the refrigerant bottle3.Open the LOW valve ref. 25 and close the HIGH valve ref. 264.Press the Vacuum key on the control module5.Set a vacuum time of 5 minutes by means of the UP/DOWN arrowsPress the START key to start the functionOnce the vacuum cycle is completed, slowly open the valve on the bottle containing refrigerantPress the Recovery keySet the refrigerant quantity to recover (we suggest a quantity of 3.000 kg) by means of the UP/DOWN arrowsPress the START key to start the functionWait until the recovery cycle is completed. A sound signal will let the user know that the cycle is over.Close the valve on the bottle containing refrigerantStart a recovery cycle with ALL setWait for the end of the cycleDisconnect the hose of the bottleRe-place the valve ref. 55 on the hose end3Using COOLIUS-1000 unit3.1Refrigerant recovery1.Turn on the engine with closed hood2.Turn the air-conditioner on and have it run for some minutes3.Open the hood and set the air-conditioner fan to maximum speed4.Have the vehicle engine run slowly (800 - 1200 revolutions/min) for a few minutes5.Turn the vehicle engine off and have the air-conditioner fan run at maximum speed and start t he recoveryoperations6.Connect the hoses to the A/C system which needs a maintenance7.Open the LOW (ref. 25) and HIGH (ref. 26)valves according to how the connection on the system wasmade8.Press the Recovery keyThe unit sets the recovery function on ALL by defaultPress the START key to start the function. During the recovery cycle, the recovered refrigerant quantity appears on the display.In case of emergency, it is possible to leave the function by keeping the STOP key pressed for more than 3 seconds.During the cycle, the unit performs the automatic oil discharge.Wait for the function to be completed; the quantities of recovered refrigerant and oil will appear on the display.3.2Vacuum + Vacuum Test1.Connect the hoses to the A/C system which needs a maintenance2.Open the LOW (ref. 25) and HIGH (ref. 26)valves according to how the connection on the system wasmade3.Press the Vacuum key.Set a vacuum time by means of the UP/DOWN keys. We suggest a vacuum time of at least 30 minutes. Press the START key to start the function. (In case of emergency, it is possible to leave the function by keeping the STOP key pressed for more than 3 seconds)When the vacuum cycle is over, the test starts to check the possible presence of leaks in the A/C system. When the vacuum test is over, or if there are leaks, a sound signal will inform the user3.3Oil / Uv - Refrigerant1.Connect the hoses to the A/C system which needs a maintenance2.Open the LOW (ref. 25) and HIGH (ref. 26)valves according to how the connection on the system wasmade3.Press the Charge key4.The operator will be asked to select the type of charge: whether it will be effected through a single hose(blue or red) or whether it will be effected through both hoses. This enables the unit to calculate the correct value of the pre-charge (when it is set).5.Confirm with START and then the screen for setting the oil/UV quantity will appear.6.The units sets SAME by default. During the oil injection phase, the same quantity of oil that has beenrecovered during recovery will be re-injected into the system.7.The units checks the maximum quantity that can be charged and indicates it on the second line of thedisplay.8.In case you would like to set a different quantity than SAME, you can modify it the quantity by means of theUP/DOWN arrows and confirm with START.Suggested quantities for refilling the A/C system with oilAccording to the type of A/C system component you have replaced, you need to fill in the lubricant quantity indicated below, even if no oil has been extracted during recovery. Evaporator: 50cc Condenser: 30cc Filter: 10cc Pipes:10ccIn any case the operator must follow the instructions of the A/C system manufacturer9. Press START and the screen for setting the refrigerant quantity will appear10. If you press START on the first line, the refrigerant quantity can be set manually, by means of theUP/DOWN arrows and confirming with START .11. Otherwise, on the second line, you can gain access to the database and choose between StandardDatabase (containing the main cars on the market) and Personal Database (created by the user).12. After having set the refrigerant quantity either by means of the manual menu or by means of the databasemenu, you will have the START screen (cycle start) where the settings will be summarized on the second line.13. Press START to start the function.14. When the function is completed, a beep will let the operator know that the cycle is over and the display willshow the information on the cycle just performed.3.4 Automatic cycle1. Connect the hoses to the A/C system which needs a maintenance2. Open the LOW (ref. 25) and HIGH (ref. 26) valves according to how the connection on the system wasmade 3. Press the Auto keyThe operator will be asked to select the type of charge: whether it will be effected through a single hose (blue or red) or whether it will be effected through both hoses. This enables the unit to calculate the correct value of the pre-charge (when it is set)Confirm with START and then the screen for setting Vacuum will appearModify the vacuum time by means of the UP/DOWN arrows and confirm with START.Now the screen for setting the oil/UV quantity appearsThe units sets SAME by default. During the oil injection phase, the same quantity of oil that has been recovered during recovery will be re-injected into the system.The units checks the maximum quantity that can be charged and indicates it on the second line of the display. In case you would like to set a different quantity than SAME, you can modify it the quantity by means of the UP/DOWN arrows and confirm with START.Suggested quantities for refilling the A/C system with oilAccording to the type of A/C system component you have replaced, you need to fill in the lubricant quantity indicated below, even if no oil has been extracted during recovery.Evaporator: 50ccCondenser: 30ccFilter: 10ccPipes: 10ccIn any case the operator must follow the instructions of the A/C system manufacturer4.Press START and the screen for setting the refrigerant quantity will appear5.If you press START on the first line, the refrigerant quantity can be set manually, by means of theUP/DOWN arrows and confirming with START.6.Otherwise, on the second line, you can gain access to the database and choose between StandardDatabase (containing the main cars on the market) and Personal Database (created by the user).7.After having set the refrigerant quantity either by means of the manual menu or by means of the databasemenu, you will have the START screen (cycle start) where the settings will be summarized on the second line.8.Press START to start the function.9.When the function is completed, a beep will let the operator know that the cycle is over and the display willshow the information on the cycle just performed.3.5Flushing1.Connect the hoses to the A/C system which needs a maintenance2.Open the LOW (ref. 25) and HIGH (ref. 26)valves according to how the connection on the system wasmade3.Press the UP/DOWN keys to enter the function menuSet the vacuum time by means of the UP/DOWN arrows and press the START key to confirmSet the number of cycles by means of the UP/DOWN arrows and press the START key to start the function When the function is completed, a sound signal will let the user know that the cycle is over and the summary of the operation performed will be displayed.3.6Checking A/C system operating pressures1.Make sure that the LOW (ref. 25) and HIGH (ref. 26)valves are closed and that the power switch (ref. 67)is on position 0Connect the 53 hose to the cooling system low pressure sideConnect the 52 hose to the cooling system high pressure sideStart the compressor of the A/C systemRead the pressure and its corresponding evaporation temperature on the 68 pressure gaugeRead the pressure and its corresponding condensing temperature on the 69 pressure gaugeg) Compare the values with the ones suggested by the cooling system manufacturer3.7Disconnecting the unit from the A/C system1.Disconnect the 52 hose from the A/C system with the A/C system compressor working.2.Make sure that the 53 hose is connected to the A/C system3.Open the LOW (ref. 25) and HIGH (ref. 26)valves in order to have all the liquid refrigerant be sucked bythe A/C system4.As soon as the pressures on the high and low pressure gauges are the same and do not exceed 2÷3 bar,disconnect the 53 hose from the A/C system5.Perform a recovery cycle to extract the remaining refrigerant from the hoses so that the unit is immediatelyready for the next operation6.Turn the unit off (power switch 67 in position 0)7.Close the LOW (ref. 25) and HIGH (ref. 26)valves8.Reposition 52 and 53 in their supports9.Carefully screw the protective caps on the A/C system service valvesing a leak detector, check the A/C system for leaksWARNING: The introduction of tracer additives and the following use of a UV leak detector will make iteasier to locate the point of the possible leak in the future.3.8Setting MenuIf you press the MENU key in the standby screen, you can gain access to the setting menu of the unit.Car plate: By pressing the START key, it is possible to type the plate of the car on which you aremaking maintenance. You can modify each single field by means of the UP/DOWN arrows andmove forward by means of the START key. When the car plate number has been typed, press theMENU key to leave.Language: By pressing the START key, it is possible to change the language of the unit. Shift through the languages by means of the UP/DOWN arrows and confirm with START.Unit of measurement: By pressing the START key, it is possible to modify the unit of measurement(INTERNATIONAL or IMPERIAL). Shift by means of the UP/DOWN keys and confirm with STARTInner Database: By pressing the START key, it is possible to make your own database. Shift onto the field you want to modify by means of the UP/DOWN keys and confirm with START. Modify each digit by means of the UP/DOWN arrows and confirm with START. Then type the value of the refrigerantcharge by means of the UP/DOWN arrows and confirm with STARTDate and Hour: By pressing the START key, it is possible to set the date and hour. Modify each value by means of the UP/DOWN arrows and confirm with START.CalibrationService: By pressing the START key, it is possible to make some service operations using several keys combinations.With the following combination: Recovery - Down - Charge - Vacuum , it is possible to cancel all the data saved on the SD-CardWith the following combination: Vacuum - Charge - Down - Up , it is possible to reset all the scalesContrast: By pressing the START key, it is possible to modify the value of the display contrast.Data exportation: By pressing the START key, it is possible to export the services performed by the unit into the SD-card (from inside memory to SD-Card). The unit creates a .txt file to import into your own PC. In case the message “ERROR CODE 08” appears, re-start the unit and try again the exportation procedure.To cancel all the data saved in the memory card, follow the procedure explained at “Service”Workshop data: By pressing the START key, it is possible to modify the 6 lines available on the report to write some information about your own workshop. Once the information have been written, they will be printed on each report.4Accessories and spare partsPart number Description14015013 XH412 anti-acid filter direr12002003 l oil for vacuum pump14020014001 G19020 kit of gaskets for ¼’ SAE hoses - 10pcs 14020015001 G19030 kit of gaskets for 3/8’ SAE hoses - 10pcs 14025079 Printer update kitSupportFor more support please contact your local service partner.Newer versions of this manual please go to our homepage.WOW! Würth Online World GmbH Schliffenstraße Falkhof74653 Künzelsau+49 (0) 7940/15-1770+49 (0)7940/15-3299*******************。

GS61008P底面冷却100V E模式GaN晶体管数据手册说明书

GS61008P底面冷却100V E模式GaN晶体管数据手册说明书

The thermal pad (pad 5) must be connected to Source, S (pad 4)Package OutlineFeatures• 100 V enhancement mode power transistor • Bottom-side cooled configuration • R DS(on) = 7 mΩ • I DS(max) = 90 A• Ultra-low FOM die• Low inductance GaN PX ® package• Simple gate drive requirements (0 V to 6 V) • Transient tolerant gate drive (-20 V / +10 V) • Very high switching frequency (> 10 MHz) • Fast and controllable fall and rise times • Reverse current capability • Zero reverse recovery loss• Small 7.6 x 4.6 mm 2 PCB footprint• Source Sense (SS) pin for optimized gate drive •RoHS 3 (6 + 4) compliantApplications• Energy Storage Systems• AC-DC Converters (secondary side) • Uninterruptable Power Supplies • Industrial Motor Drives • Fast Battery Charging • Class D Audio amplifiers • Traction Drive • Robotics•Wireless Power TransferDescriptionThe GS61008P is an enhancement mode GaN-on-silicon power transistor. The properties of GaN allow for high current, high voltage breakdown and high switching frequency. GaN Systems innovates with industry leading advancements such as patented Island Technology®andGaN PX®packaging .IslandTechnology® cell layout realizes high-current die and high yield. GaN PX® packaging enables low inductance & low thermal resistance in a small package. The GS61008P is a bottom-side cooled transistor that offers very low junction-to-case thermal resistance for demanding high power applications. These features combine to provide very high efficiency power switching.Circuit SymbolAbsolute Maximum Ratings (T case = 25 °C except as noted)Parameter Symbol Value Unit Operating Junction Temperature T J-55 to +150 °C Storage Temperature Range T S-55 to +150 °C Drain-to-Source Voltage V DS100 V Drain-to-Source Voltage - transient (Note 1) V DS(transient)120 V Gate-to-Source Voltage V GS-10 to +7 V Gate-to-Source Voltage - transient (Note 1) V GS(transient)-20 to +10 V Continuous Drain Current (T case = 25 °C) I DS90 A Continuous Drain Current (T case = 100 °C) I DS65 A Pulse Drain Current (Pulse width 50 µs, V GS = 6 V) (Note 2) I DS Pulse140 A(1) For < 1 µs(2) Defined by product design and characterization. Value is not tested to full current in production.Thermal Characteristics (Typical values unless otherwise noted)Parameter Symbol Value Units Thermal Resistance (junction-to-case) – bottom side RΘJC0.55 °C /W Thermal Resistance (junction-to-ambient) (Note 3) RΘJA23 °C /W Maximum Soldering Temperature (MSL3 rated) T SOLD260 °C (3) Device mounted on 1.6 mm PCB thickness FR4, 4-layer PCB with 2 oz. copper on each layer. Therecommendation for thermal vias under the thermal pad are 0.3 mm diameter (12 mil) with 0.635 mm pitch (25 mil). The copper layers under the thermal pad and drain pad are 25 x 25 mm2 each. The PCB is mounted in horizontal position without air stream cooling.Ordering InformationOrderingcode Package type Packingmethod QtyReelDiameterReelWidthGS61008P-TR GaN PX® bottom cooled Tape-and-Reel 3000 13” (330mm) 16mm GS61008P-MR GaN PX® bottom cooled Mini-Reel 250 7” (180mm) 16mmElectrical Characteristics (Typical values at T J = 25 °C, V GS = 6 V unless otherwise noted)ParametersSym.Min.Typ. Max. Units ConditionsDrain-to-Source Blocking Voltage V (BL)DSS 100 V V GS = 0 V, I DSS = 50 µA Drain-to-Source On Resistance R DS(on) 7 9.5 m Ω V GS = 6 V, T J = 25 °C I DS = 27 ADrain-to-Source On Resistance R DS(on) 17.5 m Ω V GS = 6 V, T J = 150 °C I DS = 27 AGate-to-Source Threshold V GS(th) 1.1 1.7 2.6 V V DS = V GS , I DS = 7 mA Gate-to-Source Current I GS 200 µA V GS = 6 V, V DS = 0 V Gate Plateau VoltageV plat 3.5 V V DS = 50 V, I DS = 90 A Drain-to-Source Leakage Current I DSS 0.5 50 µA V DS = 100 V, V GS = 0 V T J = 25 °CDrain-to-Source Leakage Current I DSS 100 µA V DS = 100 V, V GS = 0 V T J = 150 °CInternal Gate Resistance R G 0.8 Ω f = 5 MHz, open drain Input Capacitance C ISS 600 pF V DS = 50 V V GS = 0 V f = 100 kHzOutput Capacitance C OSS 250 pF Reverse Transfer Capacitance C RSS 12 pF Effective Output Capacitance, Energy Related (Note 4)C O(ER) 302 pF V GS = 0 VV DS = 0 to 50 VEffective Output Capacitance, Time Related (Note 5) C O(TR) 385 pF Total Gate Charge Q G 8 nC V GS = 0 to 6 V V DS = 50 V I DS = 90 AGate-to-Source Charge Q GS 3.5 nC Gate threshold charge Q G(th) 1.9 nC Gate switching charge Q G(sw) 3.3 nC Gate-to-Drain Charge Q GD 1.7 nC Output ChargeQ OSS 20 nC V GS = 0 V, V DS = 50 V Reverse Recovery ChargeQ RRnC(4) C O(ER) is the fixed capacitance that would give the same stored energy as C OSS while V DS is rising from 0 V to the stated V DS (5) C O(TR) is the fixed capacitance that would give the same charging time as C OSS while V DS is rising from 0 V to the stated V DS.(6) L P is the switching circuit parasitic inductance. (7) See Figure 16 for switching loss test circuit.Electrical Performance GraphsI DS vs. V DS Characteristic I DS vs. V DS CharacteristicFigure 1: Typical I DS vs. V DS @ T J = 25 ⁰C Figure 2: Typical I DS vs. V DS @ T J = 150 ⁰C R DS(on) vs. I DS Characteristic R DS(on) vs. I DS CharacteristicFigure 3: R DS(on) vs. I DS at T J = 25 ⁰C Figure 4: R DS(on) vs. I DS at T J = 150 ⁰CElectrical Performance GraphsI DS vs. V DS, T J dependence Gate Charge, Q G CharacteristicFigure 5: Typical I DS vs. V DS @ V GS = 6 V Figure 6: Typical V GS vs. Q G @ V DS = 50 V Capacitance Characteristics Stored Energy CharacteristicFigure 7: Typical C ISS, C OSS, C RSS vs. V DS Figure 8: Typical C OSS Stored EnergyElectrical Performance GraphsReverse Conduction Characteristics Reverse Conduction CharacteristicsFigure 9: Typical I SD vs. V SD at T J = 25 ⁰C Figure 10: Typical I SD vs. V SD at T J = 150 ⁰CI DS vs. V GS Characteristic R DS(on) Temperature DependenceFigure 11: Typical I DS vs. V GS Figure 12: Normalized R DS(on) as a function of T JThermal Performance GraphsI DS - V DS SOA Power Dissipation – Temperature DeratingFigure 13: Safe Operating Area @ T case = 25 °C Figure 14: Power Derating vs. T case Transient RθJCFigure 15: Transient Thermal Impedance1.00 = Nominal DC thermal impedanceTest CircuitsFigure 16: Switching Loss Test CircuitApplication InformationGate DriveThe recommended gate drive voltage range, V GS, is 0 V to + 6 V for optimal R DS(on) performance. Also, the repetitive gate to source voltage, maximum rating, V GS(AC), is +7 V to -10 V. The gate can survive non-repetitive transients up to +10 V and – 20 V for pulses up to 1 µs. These specifications allow designers to easily use 6.0 V or 6.5 V gate drive settings. At 6 V gate drive voltage, the enhancement mode high electron mobility transistor (E-HEMT) is fully enhanced and reaches its optimal efficiency point. A 5 V gate drive can be used but may result in lower operating efficiency. Inherently, GaN Systems E-HEMT do not require negative gate bias to turn off. Negative gate bias, typically V GS = -3 V, ensures safe operation against the voltage spike on the gate, however it may increase reverse conduction losses if not driven properly. For more details, please refer to the gate driver application note "GN001 How to Drive GaN Enhancement Mode Power Switching Transistors” atSimilar to a silicon MOSFET, the external gate resistor can be used to control the switching speed and slew rate. Adjusting the resistor to achieve the desired slew rate may be needed. Lower turn-off gate resistance, R G(OFF) is recommended for better immunity to cross conduction. Please see the gate driver application note (GN001) for more details.A standard MOSFET driver can be used as long as it supports 6V for gate drive and the UVLO is suitable for 6V operation. Gate drivers with low impedance and high peak current are recommended for fast switching speed. GaN Systems E-HEMTs have significantly lower Q G when compared to equally sized R DS(on) MOSFETs, so high speed can be reached with smaller and lower cost gate drivers.Many non-isolated half bridge MOSFET drivers are not compatible with 6 V gate drive for GaN enhancement mode HEMT due to their high under-voltage lockout threshold. Also, a simple bootstrap method for high side gate drive will not be able to provide tight tolerance on the gate voltage. Therefore, special care should be taken when you select and use the half bridge drivers. Alternatively, isolated drivers can be used for a high side device. Please see the gate driver application note (GN001) for more details.Parallel OperationDesign wide tracks or polygons on the PCB to distribute the gate drive signals to multiple devices. Keep the drive loop length to each device as short and equal length as possible.GaN enhancement mode HEMTs have a positive temperature coefficient on-state resistance which helps to balance the current. However, special care should be taken in the driver circuit and PCB layout since the device switches at very fast speed. It is recommended to have a symmetric PCB layout and equal gate drive loop length (star connection if possible) on all parallel devices to ensure balanced dynamic current sharing. Adding a small gate resistor (1-2 Ω) on each gate is strongly recommended to minimize the gate parasitic oscillation.Source SensingThe device has a dedicated source sense pin. The GaN PX® packaging utilizes no wire bonds so the source connection is very low inductance. The dedicated source sense pin will further enhance performance by eliminating the common source inductance if a dedicated gate drive signal kelvin connection is created. This can be achieved connecting the gate drive signal from the driver to the gate pad and returning from the source sense pad to the driver ground reference.ThermalThe substrate is internally connected to the thermal pad on the bottom-side of the package. The source pad must be electrically connected to the thermal pad for optimal performance. The transistor is designed to be cooled using the printed circuit board. The Drain pad is not as thermally conductive as the thermalpad. However, adding more copper under this pad will improve thermal performance by reducing the package temperature.Thermal ModelingRC thermal models are available to support detailed thermal simulation using SPICE. The thermal models are created using the Cauer model, an RC network model that reflects the real physical property and packaging structure of our devices. This thermal model can be extended to the system level by adding extra Rθ and Cθ to simulate the Thermal Interface Material (TIM) or Heatsink.RC thermal model:RC breakdown of R ΘJCR θ (°C/W) C θ (W∙s/°C) R θ1 = 0.017 C θ1 = 7.0E-05 R θ2 = 0.253 C θ2 = 6.7E-04 R θ3 = 0.264 C θ3 = 5.9E-03 R θ4 = 0.016C θ4 = 1.8E-03For more detail, please refer to Application Note GN007 “Modeling Thermal Behavior of GaN Systems’ GaN PX ® Using RC Thermal SPICE Models” available at Reverse ConductionGaN Systems enhancement mode HEMTs do not need an intrinsic body diode and there is zero reverse recovery charge. The devices are naturally capable of reverse conduction and exhibit different characteristics depending on the gate voltage. Anti-parallel diodes are not required for GaN Systems transistors as is the case for IGBTs to achieve reverse conduction performance.On-state condition (V GS = +6 V): The reverse conduction characteristics of a GaN Systems enhancement mode HEMT in the on-state is similar to that of a silicon MOSFET, with the I-V curve symmetrical about the origin and it exhibits a channel resistance, R DS(on), similar to forward conduction operation.Off-state condition (V GS ≤ 0 V): The reverse characteristics in the off-state are different from silicon MOSFETs as the GaN device has no body diode. In the reverse direction, the device starts to conduct when the gate voltage, with respect to the drain, V GD , exceeds the gate threshold voltage. At this point the device exhibits a channel resistance. This condition can be modeled as a “body diode” with slightly higher V F and no reverse recovery charge.If negative gate voltage is used in the off-state, the source-drain voltage must be higher than V GS(th)+V GS(off) in order to turn the device on. Therefore, a negative gate voltage will add to the reverse voltage drop “V F ” and hence increase the reverse conduction loss.Blocking VoltageThe blocking voltage rating, V (BL)DSS, is defined by the drain leakage current. The hard (unrecoverable) breakdown voltage is approximately 30 % higher than the rated V (BL)DSS,. As a general practice, the maximum drain voltage should be de-rated in a similar manner as IGBTs or silicon MOSFETs. All GaN E-HEMTs do not avalanche and thus do not have an avalanche breakdown rating. The maximum drain-to-source rating is 100 V and does not change with negative gate voltage. GaN Systems tests devices in production with a 120 V Drain-to-source voltage pulse to insure blocking voltage margin.Packaging and SolderingThe package material is high temperature epoxy-based PCB material which is similar to FR4 but has a higher temperature rating, thus allowing the device to be specified to 150 °C. The device can handle at least 3 reflow cycles.It is recommended to use the reflow profile in IPC/JEDEC J-STD-020 REV D.1 (March 2008)The basic temperature profiles for Pb-free (Sn-Ag-Cu) assembly are:•Preheat/Soak: 60 - 120 seconds. T min = 150 °C, T max = 200 °C.•Reflow: Ramp up rate 3 °C/sec, max. Peak temperature is 260 °C and time within 5 °C of peak temperature is 30 seconds.•Cool down: Ramp down rate 6 °C/sec max.Using “No-Clean” soldering paste and operating at high temperatures may cause a reactivation of the “Non-Clean” flux residues. In extreme conditions, unwanted conduction paths may be created. Therefore, when the product operates at greater than 100 °C it is recommended to also clean the “No-Clean” paste residues.Recommended PCB FootprintPackage DimensionsPart MarkingTape and Reel InformationTape and Reel Box DimensionsImportant Notice – Unless expressly approved in writing by an authorized representative of GaN Systems, GaN Systems components are not designed, authorized or warranted for use in lifesaving, life sustaining, military, aircraft, or space applications,nor in products or systems where failure or malfunction may result in personal injury, death, or property or environmental damage. The information given in this document shall not in any event be regarded as a guarantee of performance. GaN Systems herebydisclaims any or all warranties and liabilities of any kind, including but not limited to warranties of non-infringement of intellectual property rights. All other brand and product names are trademarks or registered trademarks of their respective owners. Information provided herein is intended as a guide only and is subject to change without notice. The information contained herein or any use of such information does not grant, explicitly, or implicitly, to any party any patent rights, licenses, or any other intellectual property rights. GaN Systems standard terms and conditions apply. All rights reserved.。

Singtel商业产品说明书:数据中心和云连接(DC Connect)

Singtel商业产品说明书:数据中心和云连接(DC Connect)

Singtel BusinessProduct BrochureData Centre and Cloud Connect(DC Connect)Enable a Hybrid Cloud Environment with Elastic Connections and Simplified Network Management.Singtel’s software-defined Data Centre and Cloud Connect (DC Connect) allows enterprises to easily access and seamlessly move their data between multiple data centres, various cloud services through a single connection.Data Centre and Cloud Connect (DC Connect) Enterprises are looking to simplify network management across their private clouds and public clouds to keep pace with the dynamic, on-demand nature of cloud services and achieve greater business agility while meeting the security and high-availability requirements of their mission-critical applications.(SDN). It enables your enterprise co-locating at a data centre to seamlessly access another data centre and leading public clouds through a single connection. This enables the enterprises to build a hybrid cloud environment to adopt different cloud services according to business needs.With a footprint covering the most extensive list of major data centres and public cloud platforms in Singapore, the service eliminates the need for complex interconnection and traditional network procurement. Dynamic bandwidth can be provisioned, give enterprises the agility to innovate faster, serve customers better and move ahead of the competition.FeaturesData Centre and Cloud ConnectSeamless and secure managed connectivitySecure and direct access to more than 20 key data centresin Singapore and leading cloud service providers such as Services.Secure and superior network performanceMission-critical data is transmitted over our dedicated carrier-grade Ethernet network, engineered with redundancy in the core network to deliver less than one millisecond latency and and up too 100% service availability.Centralised network managementEnables centralised management of both data centre and cloud connections through a secure web portal which allows network changes to be made anytime, from anywhere, via any device.Rapid provisioningAdditional bandwidth can be provisioned and network changes Bandwidth schedulingOne-time or recurrent bandwidth upgrades can be scheduled up to 12 weeks in advance to cater fo short-term, high-throughput data trasfer taking place between sites on a one-off or regular basis.Usage-based billingBilling is utility-based with monthly contracts and per-hour charges.How It Works• Effortlessly connects and seamlessly move data between multiple data centres andvarious cloud services to form a hybrid cloud environment• Rapid and seamless deployment ofinterconnectivity between data centres and public cloud platforms• Peace of mind with consistent networkperformance and service availability assurance Increases business agility• Early-mover advantage with near instantaneous service activation and instantiation •bandwidth scalability, granular incremental blocksand short contract terms• Centralised management and control of data centre and cloud connectivity services via an intuitive portal •manual intervention with scheduled bandwidth upgrades• Streamlines multiple connections and associated resources at the data centre• Minimise wastage with elastic services instead of utilised• Lower networking costs with usage-based model that supports small bandwidthincrements (from 10Mbps) and per-hour chargesService SchemesWhy Singtela) Data Centre ConnectA high performance Ethernet service connecting the largest network of data centres in Singaporeb) Cloud ConnectA private access connecting your private and public clouds for improved application performanceBuild your hybrid cloud environment with easescale easily. Enjoy high network availability with superb performance to accelerate your business applications.Extensive coverageWe connect a network of more than 20 data centres and public cloud platforms, the largest available locally. Peace of mindWe have a proven track record in managing high-performance enterprise networks. Our infrastructure is engineered from ground-up to accommodate the high availability demands of mission-critical applications, and is monitoredOne-stop providerAs a one-stop service provider, we deliver convenient and comprehensive support backed by a dedicated 24x7 globalhelpdesk service.Singtel is Asia’s leading communications group providing a portfolio of services including voice and pay TV. The Group has presence in Asia, Australia and Africa with over 600 million mobile customers in 25 countries, including Bangladesh, India, Indonesia, the Philippines and Thailand. About SingtelAwardsComputerworld Readers Choice AwardsManaged Connectivity & Managed Services (2006 -2015)Computerworld HK AwardsGlobal WAN Connectivity Service Provider of the Year (2015-2016)HWM + Tech AwardsBest Telco, Singapore (2010 – 2016)Best Fibre Broadband Service, Singapore (2010 – 2016) Service Provider of the Future (2013, 2015)NetworkWorld Asia Info Mgmt AwardsSecurity-as-a-Service (2012 - 2016)Disaster Recovery & Business Continuity (2014 - 2016) NetworkWorld Asia Readers’ Choice AwardsManaged Infrastructure Services (2012 – 2015)Managed Security Services (2014-2015)World Communication Awards 2015Best Enterprise Service – Managed Hybrid NetworkAugust218。

PC SC-lite 1.3 安装指南说明书

PC SC-lite 1.3 安装指南说明书

PC/SC-lite 1.3 Installation Guide February 2011PC/SC-lite 1.3Installation GuideCopyright © 2011, Oracle and/or its affiliates. All rights reserved.This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing.If this software or related documentation is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the following notice is applicable:U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial Computer Software License (December 2007). Oracle USA, Inc., 500 Oracle Parkway, Redwood City, CA 94065.This software is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure the safe use of this software. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software in dangerous applications.Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Other names may be trademarks of their respective owners.This software and documentation may provide access to or information on content, products, and services from third parties. Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect tothird-party content, products, and services. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services.1. 2. 3.PCSC-lite 1.3 Installation GuidePC/SC-lite 1.3 Installation GuideThis distribution is an update release (the previous version was PC/SC-lite 1.2) an implementation of the PC/SC-lite API, derived from the Open Source M.U.S.C.L.E. project.PC/SC (Personal Computer/Smart Card) is the standard framework for smart card device access on Windows, Linux, and UNIX platforms.The distribution contains a base package that installs the PC/SC-lite infrastructure for the Solaris platform, and an optional package that enables interoperability with the integrated Sun Ray smart card readers on Sun Ray thin clients (Solaris platform only). Support for external USB readers is supplied by the CCID handler, as a separate download.Released with this distribution is as a seperate download bundle. provides diagnostic tools and workarounds for some pcsctools pcsctools limitations. contains documentation for each tool in the bundle, including a document in that describes to enable debug logging pcsctools of all sorts for PC/SC-lite.For the list of known issues, see the .PC/SC-lite 1.3 Release Notes Supported PlatformsPC/SC-lite 1.3 is supported on the following operating systems:Solaris 10 5/08 or later on SPARC and x86Solaris 10 5/08 or later on SPARC and x86 with Trusted ExtensionsImportant NotesAt least one of the available optional packages must be installed along with the PC/SC-lite base package to enable it to work with arespective set of readers. The two optional packages currently available are a package that provides PC/SC-lite access to readers on Sun Ray thin clients, and a package that provides PC/SC-lite access to external USB readers.If both the Sun Ray support package and the USB support package are installed, then USB readers connected to Sun Ray units can beutilized, which goes beyond the access to system console USB readers afforded by the USB support package alone.The optional Sun Ray support package requires Sun Ray Server Software (SRSS) 4.1 or later.SUNWpcscdtu How to Install PC/SC-lite 1.3NoteTo install PC/SC-lite 1.3 in a Solaris Trusted Extensions environment, perform the following steps as root from ADMIN_LOW(global zone).Download the and make it accessible to the Sun Ray server.Sun Ray Software 5.1 Media Pack Remove only the following packages from the Sun Ray Server:SUNWsrcbpSUNWocfdSUNWocfhSUNWocfrSUNWpcscliteSUNWpcsclite-develSUNWjcomPlease the dependency warnings that appear during the operations to remove these packages.disregard pkgrm3. 4. a. b. c. d. e. f. 5. 6. 7. If you are in a Solaris Trusted Extensions environment, follow steps 3 and 4; otherwise, skip to step 6.Add shared multilevel port 5999 to global zone to allow local zone access.Start the SMC GUI.Under Management Tools-SelectSelect System Configuration->Computers and Networks->Trusted Network Zones->globalFrom the menu bar, select Action->Properties.Perform one of the following steps: Click Add under Multilevel Ports for Shared IP Addresses to enable port for shared IPaddresses Click Add under Multilevel Ports for Zone's IP Addresses to enable ports for zone-specific IP addresses.or Add 5999 as Port Number, Select TCP as Protocol, and click OK.Restart service using the following command:tnctl Verify that these ports are listed as shared ports by running the following command:Install the PC/SC-lite 1.3 base package , and optional Sun Ray package .SUNWpcsc SUNWpcscdtu To enable PC/SC-lite 1.3 Sun Ray support. install optional package:SUNWpcscdtu To enable PC/SC-lite 1.3 external USB reader support, download and install the package from the optional CCID distribution using the instructions provided with that separate download.。

SG2安全光帛说明书

SG2安全光帛说明书

SG2-S3-080-PP-W SG2-S4-090-PP-WThe new SAFEasy TM SG2light curtains represent the natural evolution of the SF2series.The new SG2series offers two models, SG2-B “Base ” and SG2-E “Extended ”,thus guaranteeing maximum compatibility with the SF2 series (SG2-B ), as well as offering advanced functions for a Type 2 safety light curtain, such as EDM and Anti-Interference (SG2-E ). Models with controlled heights ranging from 150 to 1800 mm are available, all with an operating distance reaching 19 m. The response times ranging from 8 to 24 msec result to be amongst the lowest on the market, consenting the installation of the product nearer to the dangerous area.As well as offering the base functions present in the SG2-B model, the SG2-E series integrates advanced functions for a Type 2 device such as manual/automatic Restart, EDM function, Anti-interference system (obtained thanks to the reduction to 9 m of the maximum operating distance). All selectable functions.The new profile and rotating fixing brackets ease installation and the alignment of the emitting and receiving units, even at long distances and in applications with deviating mirrors.The SG2series represents the ideal solution for all the typical applications of a Type 2 safety light curtain.SG2-HAND SERIESS A F E T Y D E V I C E SS A F E a s y TM :s a f e t y i n y o u r h a n d s•Integrated light curtain for HAND PROTECTION •Maximum operating distance reaching 19 m •Controlled heights ranging from 150 to 1800 mm •New sturdy profile and rotating brackets•Selectable Manual/Automatic Restart, EDM and Anti-InterferenceVERSIONS L 1 L 2 SG2-30-015-OO-*233.3153.3SG2-30-030-OO-*383.2303.2SG2-30-045-OO-*533.2453.3SG2-30-060-OO-*683.2603.2SG2-30-075-OO-*833.2753.3SG2-30-090-OO-*983.2903.2SG2-30-105-OO-*1133.21053.2SG2-30-120-OO-*1283.31203.3SG2-30-135-OO-*1433.21353.2SG2-30-150-OO-*1583.31503.3SG2-30-165-OO-*1733.31653.3SG2-30-180-OO-*1883.31803.3* = X Base model or E-C Extended modelmm-Easier and quicker installation thanks to the new rotating fixing brackets that ease alignment even in the harshest conditions -SG2-B 100% compatible with SF2-SG2-E with selectable PLUS functions, such asManual/Automatic Restart, EDM and Anti-Interference thanks to the reduction of the maximum operating distance from 19 to 9 mL 1L 2161636912143832.350.5125CONNECTIONSOSSD1OSSD20 V+24 Vdc+24 VccNONOTEST/RESET RESET/REST ARTSEL. MAN / AUTO RESTART1= brown = +24 Vdc 2= white = OSSD13= blue = 0V 4= black = OSSD25=grey = TEST/RESET+24 VdcNOT USEDNOT USED0 V0 V1= brown = +24 Vdc 2= white = NOT USED 3= blue = 0V4= black = NOT USED1 =white =RESET (*)2 =brown =+24 Vdc3 =green =EDM ACTIV A TION4 =yellow =EDM5 =grey =OSSD16 =pink =OSSD27 =blue =0 V8 = red = SEL. MAN. / AUTO RESTART1=brown =+24 2= white =TEST 3= blue =0 V 4= black =SEL. OPERA DISTANCE INDICATORS AND SETTINGSEMITTER (TX)*Automatic RESTART - RESET functionManual RESTART - RESET/RESTART functionOSSD1EDMEDMACTIVATIONOSSD2 +24 Vdc +24 VdcSEL.OPERATING DISTANCE0 VTEST+24 VdcNOSG2-E12341234123413456782Response time:Refer to tableControlled height:150...1800 mmSafety category:Type 2Auxiliary functions:SG2-B Reset / TestAutomatic RestartSG2-E Reset / TestMan./Auto RestartSelectable EDMElectrical protection:Class I / Class IIIConnections:SG2-B M12 4-pole for emitterM12 5-pole for receiverSG2-E M12 4-pole for emitterM12 8-pole for receiverCable length (for powering):50 m max *OPTICAL DA T A Light emission:Infrared LED (950 nm)Resolution:30 mmOperating distance:0.2…19 m (SG2-B)selectable 0.2…9 m / 0.2…19 m (SG2-E)Aperture angle (EAA) :± 5°Ambient light rejection:IEC-61496-2MECHANICAL AND ENVIRONMENT AL DA T A Operating temperature:0…+ 55 °C Storage temperature:- 25…+ 70 °C Temperature class:T6Humidity:15…95 % (non condensanting)Mechanical protection:IP 65 (EN 60529)Vibrations:0.35 mm amplitude10 … 55 Hz frequency, 20 sweep per axis 1octave/min (EN 60068-2-6)Shock resistance:16 ms (10 G) 1.000 shock per axis(EN 60068-2-29)Housing material:Painted a luminium (yellow RAL 1003)Protective shield materiale:PMMA Cap material:PC MAKROLON Weight: 1 kg / m *If a longer cable has to be used, please verify that the capacitive load specifications are respected816243240485664SG2 height 1350 72SG2 height 1500 80SG2 height 1650 88SG2 height 1800 96Table 2: CONTROLLED HEIGHT (mm)ModelSG2 height 150150SG2 height 300300SG2 height 450 450SG2 height 600600SG2 height 750750SG2 height 900 900SG2 height 1050 1050SG2 height 12001200SG2 height 1350 1350SG2 height 1500 1500SG2 height 1650 1650SG2 height 18001800Table 1: NUMBER OF CONTROLLED BEAMS Table 3: RESPONSE TIME (ms)ModelSG2 height 1508SG2 height 3009SG2 height 450 11SG2 height 60012SG2 height 75014SG2 height 900 15SG2 height 1050 17SG2 height 120018SG2 height 1350 20SG2 height 1500 21SG2 height 1650 23SG2 height 180024pendingControlled height range extended from 150 to 1800 mmThe controlled height extended to 1800 mm allows SG2 to be used in applications where high areas have to beprotected.Response time reductionThe SG2 light curtain can be installed even closer to the dangerous area thanks to improved response times, thus reducing the machine dimensions and consequently the plant costs. Moreover, SG2, as are as the response times areconcerned, can be interchanged with the corresponding products of the major manufacturers.150 mm1800 mmAnti-Interference systemThe Anti-Interference system consents the installation of different light curtains aligned one next to the other avoiding mutual optical interference, without the need to install separating shields.Optical interferenceTX 1: maximum operating distanceTX 1: reduced op. distance 19 m9 m220 Vac220 Vac+24 Vdc 11112222-Automatic and semi-automatic assembling lines;-Automatic warehouses.Example 1: Hand protection on forming machineThe aim is to prevent the squashing of operator hands during stackingoperations. The solution must not interfere with the productionprocess.Solution: the IP69K protection is obtained through an acrylic PMMAtube and offers an effective protection without trapping dirt orcontamination. The cap prevents water or dirt from entering the tubeand at the same time, prevents also internal condensation. The cableconnection is protected and fixed by a PG gland that prevents wateror dirt from entering the tube.Advantages: the profile dimension and rotating fixing bracket resolvetypical applications that require fixing in reduced space, guaranteeing maximum installation flexibility and adaption to the machine dimensions.Example 2: Cooling and air-conditioning systemsCooling and air-conditioning systems as well as devices and components forauto vehicles are controlled inside a machine to check leaks, using a helium-based spectrometer The point where the components are poisitoned in themeasurement room has to be protected in full compliance with Type 2requirements, guaranteeing space reduction and the safe access to aprotected area.Solution: the SG2 light curtain represents the best solution considering thesafety requirements and the application. The test machine is immediatelystopped even when only one of the beams is interrupted.Advantages: the SG2 light curtain satisfies the customer needs in terms ofaccess simplicity in presence of a machine stop. Easy installation, configuration and use are other advantages.Example 3: Automatic warehousesThe SG2 Type 2 light curtain represents the ideal solution to protect the operator fromhand squashing, abrasion and loss, or parts of it due to the moving parts.Solution: the SG2 light curtain represent the best solution considering the safetyrequirements and the application. The carousel is immediately stopped even when onlyone of the beams is interrupted.Advantages: the profile and fixing systems ease and speed up installation. The excellentperformances (operating distance, controlled heights and response times) guaranteemaximum plant flexibility.3530°30Ø 6.6Ø 6.5BA12.95CL *L 112.751.5125.55.51716.251533R2.718.517.525.637.834.52663963076618518.5178Installation with anti-vibration supports* Supplied in the packageDistributed by:SG2-S3-080-PP-W SG2-S4-090-PP-W。

Star Cool 冷機 使用手冊说明书

Star Cool 冷機 使用手冊说明书

版本 810906C 2021年5月型號 SCI-20/40/CA 和 SCU-20/40112頁中的1頁1. 前言此版手冊發佈於2021年5月, 由馬士基集裝箱工業公司編輯. 版權所有.此用戶手冊是針對軟件版本0357或更高版本發佈的.此手冊資訊如有變更, 恕不另行通知,亦不代表馬士基集裝箱工業公司任何部門的承諾. 然而此手冊的資訊被認為是正確的, 馬士基集裝箱工業公司對其中的任何錯誤或遺漏不承擔責任.此手冊對如下有效:型號SCI - 20/40/CA and SCU - 20/40軟體版本03572. 警告如果您還沒有熟讀此手冊指導, 沒有完全弄懂此設備和操作,請不要操作或維修此製冷機組.在沒有斷開電源插頭之前請不要對機組動焊. 而且, 還需要斷開電源偵測模組與主控制器(如果安裝了貓也需要斷開).在檢查電控箱內部時請斷開機組的主供電電源.機組充注了R134a或R513A製冷劑和BSE 55型號的酯類潤滑油. 不要使用任何其它型號的製冷劑或潤滑油. 不要使用污染的製冷劑或潤滑油. 永遠不要向大氣中直接排放製冷劑. 請根據當地法律使用資源回收裝置.在維修過程中, 請注意製冷劑工作時, 產生高溫和低溫並伴有高壓的, 如果處理不當可能會造成人員受傷.在回收和製冷系統維修過程中, 個人防護用品必須穿戴齊全.在釺焊時要確保銅管內無殘留的液體製冷劑. 這可能會導致銅管爆炸.請注意一些型號的機組的吸氣壓力感測器(Psuc)和排氣壓力感測器(Pdis)沒有安裝閥針.我們不建議用PH值低於7的肥皂/洗滌劑來清洗冷藏箱內. 然而,如果這已經發生了, 請使用 PH值介於 7 到 9 之間的洗滌劑透過馬達檢查視窗來清洗蒸發器盤管. 這步清洗對減少蒸發器盤管腐蝕的風險至關重要.當箱內氧氣含量低於20.9%時不要進入箱內,也不要打開馬達服務蓋板. 無論是維修機組還是拆貨, 進入之前請務必進行通風. 通風時要遠離門端.人體對低氧環境的反應:112頁中的2頁3. 內容1. 前言 (1)2. 警告 (1)3. 內容 (2)4. 職權範圍 (6)5. 總覽 (8)6. 功能描述 (9)6.1 啟動過程 (9)6.2 溫度控制 (9)6.3 容量控制和限制器 (9)6.4 電路控制 (11)6.5 膨脹閥.... (11)6.6 經濟器閥 (11)6.7 除濕........ (11)6.8 冷凝風扇 (12)6.9 蒸發風扇 (12)6.10 化霜功能 (13)6.11 警報回應系統 (13)6.12 資料記錄 (13)7. 測試 (16)7.1 功能測試 (16)7.2長PTI (17)7.3 短PTI (17)7.4 氣調 PTI (17)8. 製冷系統資料 (18)8.1 製冷劑充注 (18)8.2 規範總覽 (18)8.3 壓縮機 – 馬達組件 (18)8.4 變頻器 (FC) (18)8.5 蒸發器盤管 (18)8.6 蒸發器盤管加熱器 (18)8.7 蒸發器風扇 (19)8.8 蒸發器風扇馬達 (19)8.9 冷凝器盤管 (19)8.10 冷凝器風扇 (19)8.11 冷凝器風扇馬達 (20)8.12 水冷冷凝器 (可選的) (20)8.13 新風交換 (20)8.14 新風交換馬達 (20)8.15 經濟器 (21)8.16 製冷控制 (21)8.17 真空泵, 包含泵加熱器 (21)8.18 電氣參數 (21)8.19 斷路器 (21)8.20 接觸器 (21)8.21 高壓切斷開關 (21)8.22 易熔塞, 儲液罐 (22)8.23 保險絲 (22)8.24 電纜插頭 (22)8.25 電纜線 (22)8.26 USDA插口規範 (22)112頁中的3頁8.27 O2 感測器 (22)8.28 CO2 感測器 (22)8.29 溫度感測器, 包括 USDA (23)8.30 濕度傳感器 (23)8.31 CA 壓力感測器 (23)8.32 壓力感測器 (23)8.33 其它項 (23)9. 使用者介面 (24)9.1 指示燈 (24)9.2 顯示幕 (24)9.3 按鍵板 (25)10. 菜單綜述 (26)10.1 頁面總體佈局 (26)10.2 使用游標 (27)10.3 改變參數 (27)10.4 啟動一個功能 (27)10.5 新風交換介面 (27)11. 操作 (28)11.1 功能表結構 (28)11.2 操作總覽 (29)11.3 溫度設置 (29)11.4 喚醒模式 (29)11.5 顯示幕對比度調節 (29)11.6 溫度單位轉換 (29)11.7 查看溫度曲線 (29)11.8 水冷開啟/關閉 (30)11.9 PTI 或功能測試 (30)11.10 資訊功能表 (33)11.11 原始感測器數值 (37)11.12 操作功能表設定 (38)11.13 程式 (39)11.13.1 多設定溫度程式, MTS (39)11.13.2 自動冷處理, ACT (40)11.13.3 鮮花模式 (42)11.14 應用設置 (43)11.14.1 AV/AV+ (43)11.14.2 CA......... .. (43)11.15 手動化霜 (45)11.16 警報 (45)11.17 服務功能設置 (46)11.18 手動運行 (47)11.18.1 變頻器自檢 (48)11.19 數據查看 (49)11.20 時間調整 (49)11.21 執行時間計數器 (50)11.22 配置.... (51)11.22.1 StarConomy 節能模式 (52)11.23 系列號 (53)11.24 USB菜單.... .. (54)11.25 維護保養 (55)11.26 數據機 (55)12. 外接介面 (55)12.1 基本要求 (56)12.2 外接介面術語清單 (56)12.3 功能總覽 (56)112頁中的4頁13. 事件 (57)14. 詳細警報描述 (60)14.1 警報列表 (60)15. Star Cool 機組安裝尺寸 (65)16. 馬達, 溫度感測器, 濕度感測器和新風交換感測器的位置 (66)17. 閥的位置 (67)18. 馬達, 溫度感測器, 濕度感測器和新風交換感測器的位置 (68)19. 電控箱示意圖 (69)20. AV和CA部件位置 (70)21. 更換 (73)21.1 更換蒸發器馬達和風扇 (73)21.2 更換冷凝器馬達和風扇 (73)21.3 更換蒸發器盤管 (74)21.4 更換蒸發器加熱器 (75)21.5 更換變頻器 (76)21.6 更換壓縮機 (77)21.7 更換壓縮機閥板/缸頭墊片 (78)21.8 更換乾燥篩檢程式 (79)22. 維護和維修 (79)22.1 回收製冷劑 (79)22.2 壓縮機排空和操作 (80)22.3 壓縮機排空(更換後) (80)22.4 回收和抽空 (81)22.5 試壓 (81)22.6 充注製冷劑 (82)22.6.1 空機組充注 (82)22.6.2 已有部分製冷劑充注 (82)22.7 檢漏 (83)22.8 壓縮機 (83)22.8.1 檢查油位 (83)22.8.2 壓縮機泄油 (83)22.8.3 加注壓縮機油 (84)22.9 釺焊 (84)22.9.1 電焊 (85)22.10 校驗新風交換感測器 (85)22.11 通過StarView校驗溫度感測器 (85)23. CA服務和故障排除 (85)23.1 集裝箱通風流程 (85)23.2 更換真空泵油過濾器和油 (86)23.3 真空系統故障診斷 (88)23.4 更換真空泵加熱器 (89)23.5 CA 裝貨準備 (89)23.6 門帘固定膠條安裝 (89)23.7 門帘安裝 (90)23.8 CA箱氣密檢測 (91)23.9 CA+ 充氣 (91)112頁中的5頁24. 故障診斷總則 (93)25. 應急操作 (93)25.1 FC 變頻器旁通 (93)25.1.1 FC 1.0 和 FC 1.1 (93)25.1.2 FC 2.0 (94)25.2 控制器旁通 (94)25.3 蒸發器馬達旁通 (94)26. 表格 (95)26.1 資料描述 (95)26.2 溫度感測器 - 電阻表 (97)26.3 溫度感測器 - 電壓表 (98)26.4 新風感測器 電壓 - m3/h表 針對35 CMH (99)26.5 新風感測器 電壓 - m3/h表 針對75 CMH (99)26.6 電壓 - 壓力錶, 低壓壓力感測器(NSK) + DST (100)26.7 電壓 - 壓力錶, 低壓壓力感測器 (AKS (101)26.8 電壓 - 壓力錶, 高壓壓力感測器(NSK) + DST (102)26.9 電壓 - 壓力錶, 高壓壓力感測器 (AKS) (103)26.10 壓力 - 溫度錶 R134a (104)26.11 壓力 - 溫度錶 R513A (104)26.12 扭矩要求 (105)27 圖表 (106)27.1 P & I diagram (106)27.2 CA 功能總覽 - 兩個版本 (107)28. 電路接線圖 - 帶子控制器的 CIM 6.0 (109)29. 電路接線圖 - CIM 6.1 (110)30. 電路接線圖 - CIM 6.2 (111)31. 電路接線圖 - 帶子控制器的 CIM 6.2 (112)112頁中的6頁4. 職權範圍112頁中的7頁112頁中的8頁5. 總覽冷星STAR COOL冷機, 機型號為SCU-40 和 SCI-40,是基於製冷劑R134a或R513A在通電後能夠進行製冷和加熱的機組.此機組的設計保持貨物溫度範圍是 -30°C (-22°F) to +30°C (+86°F). 此機組的設計適用環境溫度範圍是 -30°C (-22°F) to +50°C (+122°F).機組前外框是由海運等級的鋁材料製成的, 5000 和 6000 系列, 被設計成完全可以用來做為集裝箱的端壁. 機組的後背板是由可以接觸食品的材料做成的.機組是以完全適用於海運環境來設計的並做如下規範:• 含鹽霧空氣, 海浪飛沫, 和高濕度.• 橫搖: 每面30° 振幅, 週期13秒.• 縱搖: 每面6° 振幅, 週期8秒.• 永久傾斜: 每面15°.• 衝擊: 橫向2g,縱向 5g.• 振動: 在船上, 卡車上, 和鐵路上可能遇見的各式振動.機組包含如下模組:• 框架模組• 冷凝器/壓縮機模組• 蒸發器模組• 蒸發器風扇模組機組的製冷系統配備了一個雙級壓縮機, 並通過一個變頻器進行驅動.此製冷系統也配備了一個經濟器, 它用來對從儲液罐到蒸發器的液體製冷劑進行過冷, 從而增加機組的製冷量.蒸發器和經濟器是由電子膨脹閥來進行控制的.此設備根據ISO 1496-2設計的供電電源為3相初級電源:50 Hz (+/- 2.5), 360-460 V AC (最高 465 V AC) 或 60 Hz (+/- 2.5), 400-500 V AC (最高 535 V AC). 控制電壓是由一個一體式的雙繞組變壓器提供的. 一個繞組輸出電壓18.6-32.0 V AC (供給RMM貓), 另外一組電壓輸出為20.5-35.7 V AC並在控制器裡轉換成直流電壓(給控制器和接觸器). 輸出電壓取決於輸入電壓. 一個自動的電源檢測和修正系統, 可以確保風扇馬達的正確轉向.這跟主電源的相序沒有關係, 但要確保所有的風扇馬達的接線是正確的.一個可選配的水冷冷凝器安裝在風冷冷凝器下端. 水冷冷凝器可以允許機組在甲板下方運行, 那裡沒有通風, 要確保外接水冷系統接通.機組為底部送風, 頂部回風回到蒸發器盤管上方 (底部送風).機組具有完全電腦化控制的自動除濕功能. 除濕設定範圍是 95 – 65% RH (或關閉新風以達到低至 50%的設定). 機組可以控制到最低值. 只有當控制溫度進入設定溫度範圍後除濕功能才能啟動. 機組裝配有加熱器, 安裝在蒸發器盤管下面, 用來進行除濕. 在經濟Economy模式下除濕功能也能啟動.機組配有雙化霜系統.系統配有一個熱氣閥, 用熱氣來輔助蒸發器盤管化霜. 而且,安裝在蒸發器盤管下面的加熱器在除霜時也會啟動. 雙化霜系統可以確保快速的完成化霜從而減少因為化霜產生的熱量對箱內溫度的影響. 雙化霜系統也能夠保證熱量均勻的分配到蒸發器盤管各個角落. 這可以防止蒸發器局部的冰不能被順利融掉. 雙化霜系統,熱氣和加熱器, 是獨立的. 這可以確保隨時都能開啟化霜過程. 嵌入到軟體裡的自動化霜系統可以確保蒸發器盤管上不會被冰封住.電子控制器是由Bitzer Electronics製造的, 在保鮮模式下控制供風溫度 (設定溫度大於等於 -5°C (+23°F), 在冷凍模式下控制回風溫度 (設定溫度小於 -5°C (+23°F). 控制器精度 ±0.25°C (±0.45°F). 機組控制蒸發器風扇以低速和高速運行.通過控制器操作介面, 中可以選擇普通模式Normal或經濟模式Economy. 在經濟模式Economy下蒸發器風扇一直低速轉. 在普通模式Normal下蒸發器風扇以高速或低速運轉, 取決於保鮮還是冷凍模式.機組配有資料記錄儀, 其嵌入到控制器裡了. 資料記錄時間間隔是預設好的, 可以選擇15, 30, 60, 120, 或 240 分鐘. USDA 感測器 (3 根) 和cargo貨物溫度感測器的資料記錄時間間隔是1小時, 這是根據USDA 的要求做的設置. 以1小時做為資料記錄時間間隔算, 資料存儲可以達到365天. 資料記錄的精度為 ±0.25°C (±0.45°F). 資料可通過電腦端 (Star-view)和Psion Logman從機組的高速串口處進行提取. 也可以通過手機APP和Star Cool Dongle (藍牙適配器)來進行提取.機組配有備用電池, 在機組斷電後可以繼續記錄資料120次. 對CIM 6, 電池是可充電的. 對CIM 5, 電池是不可充電的.根據ISO 標準 10368, 控制器可以和遠端監控設備進行通訊. 事件events, 警報alarms, 和資料datalogs可以通過各種諸如Refcon, Logman, StarView等各種系統進行下載.112頁中的9頁6. 功能描述6.1 啟動步驟啟動分為5步:1. 初始化: 控制器自檢.2. 穩定化: 蒸發器風扇高速運行以確保箱內的溫度感測器測量的是當前溫度.3. 曲軸箱加熱: 如果Tamb環境溫度低於2°C (36°F) 變頻器會加熱壓縮機線圈直到Tfc變頻器溫度超過12°C (54°F).4. 暖機.5. 結束: 切換到正常的溫度和參數控制模式.6.2 溫度控制溫度控制功能已經潛入到了控制器的系統中.這個功能有兩種模式:1. 保鮮如果設定溫度Tset大於或等於-5°C (+23°F) 則進入到保鮮模式.如果是製冷狀態則實際控制溫度Tact = Tsup供風溫度, 如果是加熱狀態則實際控制溫度Tact = Tret 回風溫度. 2. 冷凍如果設定溫度Tset小於 -5°C (+23°F) 則進入到冷凍模式並且實際控制溫度Tact = Tret 回風溫度.保鮮和冷凍模式的分界溫度取決於軟體版本和客戶要求.溫度控制是進入到下來或加熱模式取決於實際溫度Tact是高於還是低於設定溫度Tset. 只要是實際溫度未進入到設定溫度Tset ± 1.5°C範圍內, 這個功能就會保持下來或加熱模式. 如果實際溫度進入到溫度範圍內, 這個綠色的IN-RANGE 範圍內指示燈就會開始閃爍. 當實際溫度進入到設定溫度Tset ± 1.5°C 範圍內超過30分鐘, 則綠色的溫度範圍內指示燈IN-RANGE就會變成常亮.如果實際溫度超出溫度範圍超過2小時, 溫度範圍內指示燈IN-RANGE將會開始閃爍. 實際溫度超出溫度範圍超過4小時之後, 將會產生一個超出溫度範圍的警報. 根據實際溫度Tact和設定溫度Tset等輸入參數這個功能會通過控制器計算需求的容量. 需求的容量CapReq是指想要取得的製冷/加熱容量. 需求的容量CapReq數值範圍是從–100% 到 +100%.–100%是指最大的製冷量, +100%是指最大的加熱量.保鮮模式冷凍模式6.3 容量控制和限制器根據需要的容量, 此功能判斷運行模式並控制各個系統部件(壓縮機, 閥, 加熱器) 以確保取得壓縮機最少的停機時間. 此功能有5個檔位元 (模式). 根據需要的容量, 來決定進入哪個檔位.壓縮機頻率是由當前模式直接決定的. 蒸發器加熱器, 不同的是, 它的檔位是獨立的. 模式切換是有一個過程的,為了保持各個模式之間平穩過渡.機組的容量控制在最大的製冷量 (-100% capacity) 和最大的加熱量 (+100% capacity) 之間. 這是通過變頻器調節壓縮機轉速或對壓縮機進行開/關調節. 在最大的加熱量 (+100% capacity) 內機組使用加熱器加熱, 進入到容量範圍後會對加熱器進行脈衝調節來控制加熱量.下圖顯示了容量範圍.System CapacityHeating %如果任何一個限制器被觸發, 壓縮機轉速將會降低從而使機組容量降低. 當一個限制器變為活躍後, 它將會在顯示幕主頁上狀態列裡顯示出來. 限制器的類型可以在資訊功能表 , 行I40可以看到.限制器類型:• TC冷凝溫度, 最大的冷凝壓力 (和溫度) 通常出現在溫度下拉的時候. 如果此機組和其它的Star Cool機組比較起來製冷量低, 清潔冷凝器盤管, 檢查排氣壓力Pdis, 檢查冷凝器馬達的功能和轉向.• IFC變頻器電流, 變頻器FC 最高的限電流.它出現的典型條件是在溫度下拉過程中尤其是環境溫度高於25°C (77°F).如果此機組跟其它的Star Cool 機組比較起來製冷量明顯較低, 請參考警報AL 511進行故障診斷尤其是注意檢查製冷劑液位 (是否過量充注).• TFC變頻器溫度, 變頻器FC的最高溫度. 它出現的典型條件是在溫度下拉過程中尤其是環境溫度高於40°C (104°F).如果此機組跟其它的Star Cool 機組比較起來製冷量明顯較低, 請參考警報AL 511進行故障診斷.• T0蒸發溫度, 最低的蒸發壓力很少被啟動. 如果這個限制器活躍超過2分鐘, 檢查製冷劑液位 (充注不足), 檢查吸氣壓力Psuc和吸氣溫度Tsuc, 檢查膨脹閥Vexp和低壓閥板.• ITOT, 通過降低壓縮機轉速來控制機組的總電流在範圍內. 它通常會在拉溫時尤其是環境溫度高於40°C (104°F)時出現. 當總電流達到13.5 A後壓縮機允許上升的頻率會分佈降低, 當總電流達到17.5 A時壓縮機頻率會被最大程度的降低以避免出現警報AL 421從而造成機組停機甚至出現斷路器跳閘的情況.多個限制器可能同時變成活躍. 多個限制器參數會被迴圈顯示. 最緊急的參數會被用來控制容量. 如果限制參數高於需要的容量變化, 容量實際會降低而不會增加. 比如當環境溫度很高時, 需求的容量會要求提升變頻器FC 的溫度, 當變頻器溫度超限時, 限制器會降低容量直到進入到一個對變頻器安全並穩定的運行狀態.6.5 膨脹閥此功能確保蒸發器過熱度(SH)為最優並計算和控制膨脹閥的開度(SHVod). 此功能只有在壓縮機工作時才生效. 壓縮機停機時膨脹閥是關閉的. 膨脹閥功能吧包含三個子功能:1. MSS (Minimum Stable Superheat search)最小穩定過熱度搜尋此功能在最小過熱度SHmin和最大過熱度SHmax之間搜尋最小的穩定過熱度. SHact: = Tsuc - T0 (Psuc)2. 過熱控制功能結果是控制膨脹閥 (Vexp)的開度. 在啟動過程中開度是0%. 電子膨脹閥使一個全開或全關的閥,它的開度是由在一個迴圈的固定時間段內開啟的時間量來決定的.3. MOP (Maximum Operating Pressure)最大的工作壓力MOP功能是為了防止吸氣壓力變得太高.6.6 經濟器閥此功能是過冷進入到蒸發器之前的液路製冷劑同時要冷卻變頻器. 除此之外, 製冷量會提高同時排氣壓力也會將帶. 功能輸出結果是經濟器膨脹閥 (Veco)開度.經濟器有兩種控制模式:1. 過熱度控制閥的開度是由計算的脈衝時間控制的.2. 變頻器冷卻壓縮機工作時此功能才啟動.6.7 除濕除濕功能是指通過啟動加熱器來降低箱內空氣中的濕度. 只用當實際溫度進入到溫度範圍以後此功能才會啟動. 除濕的取得是通過降低蒸發器盤管的表面溫度來實現的. 當加熱器啟動後就會升高蒸發器盤管的溫度從而機組會提升製冷量來降低蒸發溫度.此功能有3中模式:1. 關閉除濕功能處在關閉狀態.2. 活躍當箱內實際濕度RH高於設定的濕度值RHSet加熱器(Hevap)就會啟動,當RH低於RHSet – 3 [%]加熱器就會關閉. 除濕設定值可以設定在50% 到 95%之間. 低除濕範圍50% to 64%之間不允許打開新風交換, 而且蒸發器馬達低速運行. 除濕範圍在65% - 95%之間允許新風交換打開, 蒸發器馬達高速運行.3. 覆蓋當滿足如下條件時除濕會被覆蓋:- 製冷量超過80%- 加熱量需求較大- PTI - 出現致命警報- 無變頻器FC運行- 手動運行模式啟動- 化霜其它備註即使覆蓋功能被啟動了除濕符合 還是會出現在顯示幕上.加熱器符合 會隨著加熱器的開關而顯示或消失.除濕功能關閉設置了工作中如果除濕功能活躍:6.8 冷凝器風扇冷凝器風扇控制是通過冷凝器風迴圈來降低冷凝壓力. 如果機組用的是水冷, 冷凝壓力控制也監測壓縮機排氣壓力. 此功能只在自動運行模式下起作用.冷凝壓力控制有兩種主要途徑:1. 風冷在風冷模式下通風有如下工作方式:取決於壓縮機的排氣壓力, 冷凝風扇或者關閉或者: 高速和低速運行. 冷凝風扇有4種運行模式: 關閉, 低速, 高速 和高低速切換(每兩分鐘為時間間隔).當環境溫度Tamb高於48°C (118°F)或壓縮機排氣壓力一直保持較高, 冷凝風扇會持續高速運行.2. 水冷如果冷凝風扇執行時間超過1小時, 將會產生一個警報.冷凝風扇冷凝風扇有4種運行模式: 關閉, 低速, 高速 和高低速切換(每兩分鐘為時間間隔).6.9 蒸發器風扇蒸發器風扇功能是確保風扇的轉速正確(高或低). 此功能只在自動模式下啟動.此功能有2種模式:1. 正常Normal冷凍模式下滿足如下條件為低速運行:- 設定溫度Tset 大於等於 0°C (32°F)- 無新風交換- 除濕功能關閉或濕度設定低於65% 否則高速運行.2. 經濟Economy蒸發器風扇持續低速運行. 除非: 當Tret > Tsup + 8°C (14°F) 時高速運行, 直到 Tret > Tsup + 3°C (5°F). Economy模式需要人工打開.6.10 化霜功能化霜功能確保蒸發器結霜正常除掉. 化霜是自動的.化霜啟動• 自動化霜, 表示蒸發器需要化霜時化霜才會啟動.化霜間隔• 按需化霜系統一直監測著蒸發器盤管溫度以防止蒸發器被冰堵住. 如果系統報告蒸發器被冰堵住, 那自動化霜就會啟動.• 兩次除霜之間的最短時間為2½小時, 具體取決於操作模式.實際化霜的方式是由空氣化霜air defrost, 熱氣化霜hot gas, 和加熱器化霜electrical heaters組成的並有4步:1. 等待在等待化霜時以下參數一直被監測並更新距離化霜的時間:- 壓縮機運行- 發溫度T0低於最小的蒸發溫度T0min.等待步驟如遇見下面情況會被終止:- 計算的蒸發器覆蓋的冰量高於臨界水準(自動化霜)- 手動化霜開啟(手動化霜開始)2. 化霜準備等待冷凝溫度高於50°C (122°F), 但不超過300秒.3. 執行化霜開始執行. 在航程資料裡會記錄化霜開始事件Event. 製冷停止, 壓縮機啟動, 只進入暖機模式. 蒸發器風扇停止.蒸發器加熱器啟動. 壓縮機以全速運行的83%的固定頻率運行. 膨脹閥關閉. 熱氣閥啟動, 熱氣被壓縮機直接打進蒸發器裡在管路裡面進行加熱. 當蒸發器溫度(Tevap)高於化霜終止溫度2分鐘並且蒸發溫度T0高於1°C超1分鐘化霜終止.或超過最長的化霜時間. 化霜結束事件會記錄在資料記錄裡, 當前的化霜時間間隔和蒸發器溫度Tevap也會被記錄.4. 結束結束模式分為兩步:- 蒸發器會被重新冷卻以防止當蒸發器風扇啟動後把蒸發器上余留的水吹進箱內.- 蒸發器風扇低速運行以防止蒸發器閃蒸並確保控制器順利切換到正常的製冷模式. 化霜結束後, 機組會以化霜之前的設定溫度為准恢復到正常的製冷模式.基本資訊如果蒸發器溫度感測器Tevap出現故障, 自動適配化霜會啟動, 和正常化霜時間間隔比較起來它的化霜時間間隔會短一些. 設定溫度的改變會引起化霜時間間隔的重新計算, 如果化霜條件滿足的話會開啟化霜. 當手動化霜開啟時當前的化霜間隔會被重置為默認的化霜間隔.手動化霜終止一旦手動化霜終止, 機組會進入化霜結束模式. 當手動化霜啟動後自動適配化霜不會發生.關於使用者介面在化霜功能執行過程中化霜符合會出現在螢幕上.其它補充在化霜過程中如果選擇了服務模式或PTI模式, 當前的化霜模式會終止並且如果化霜正進入到尾聲則下次化霜時間被設置為當前值.如果因為某種原因在化霜過程中機組關機了並且關機時間小於12個小時, 當電源恢復後機組會重進進入到剩餘的化霜過程.如果關機時間超過12小時, 機組會跳出化霜過程並且進入到等待模式.6.11 警報回應系統 (AAS)此功能用來處理當有壞的感測器出現後機組如何應對. 此策略是用其它的感測器數值加常熟來取代壞的感測器數值從而讓機組在有所降低的控制精度下仍能保持運行.6.12 資料記錄控制器中含有資料記錄儀來記錄機組運行的各項參數. 資料記錄含有4項內容:• 數據• 擴展資料• 警報• 事件數據數據查看:• 顯示幕上功能表L01, 可以查看溫度文本.• 顯示幕上功能表L03, 可以查看溫度圖表.• 可通過程式RefCon及其RMM數據機和電纜線來進行查看.• 利用資料口通過專用程式, LogMan設備, 在PSION pda上來進行提取和查看.• 利用資料口通過StarView在筆記型電腦上進行提取和查看.當一個警報出現後它將會觸發一個完整的記錄, 但每15分鐘最多記錄一個.當資料記錄時間間隔設置為預設每小時記錄一次則資料記錄儀可記錄大約10.000記錄或超過1年的記錄.下面清單顯示了通過Starview和Psion Logman軟體下載的資料:D33Extended Log Type 2E x t e n d e d L o g T y p e 2D34D35D36D37D38D39D40D41D42D43D44CA datalog C A d a t a l o gD45D46D47D48D49D50Extended Log Type 3E x t e n d e d L o g T y p e 3D51D52D53D54D55D56D57Extended Log Type 4E x t e n d e d L o g T y p e 4D58D59D60D61D62D63D64D65標題Header可以通過Refcon, Logman, StarView,USB系統提取,可以通過Refcon, LogView和StarView系統查看. 擴展資料Extended Log Type 1只能通過Logman和StarView提取並生成LogView和StarView檔. 擴展資料Extended Log Type 2只能通過StarView提取並查看. StarView程式是一個專門為Star cool機組設計的程式,它通過機組的資料提取口和PC機進行通訊.7. 測試機組有5種類型的測試:1. 功能測試-Fuction test2. 長PTI測試-Full PTI (航程預檢)3. 短PTI測試-Short PTI (航程預檢)4. 智慧航程檢測-ITI (Intelligent Trip Inspection)5. 氣調PTI測試-CA PTI (Pre-Trip Inspection)ITI (Intelligent Trip Inspection)是在貨物運輸過程中執行的機組自檢程式. 目的是減免常規的當航程結束並卸貨後需要執行的PTI 檢測.PTI測試時在功能測試的基礎上再進行容量測試的檢測. 容量測試要求在一定的時間限定範圍內實際溫度要達到要求的設定溫度.當測試開始時, 一個事件event會在資料記錄裡產生.在功能測試和PTI測試過程中警報系統任然保持活躍. 如果在測試過程中出現了警報, 警報會在顯示幕上顯示, 跟正常的運行過程中出現警報是一樣的. 當測試過程中出現致命警報 (fatal alarm)時測試會停止, 機組會保持靜止狀態.當功能或PTI子測試失敗後會觸發警報”PTI FAILURE”. 當功能或PTI子測試通過後會生成事件”Test status”並顯示在顯示幕上. 詳細資訊, 請參考事件event列表.測試之前要清除所有的警報. 如果有活躍警報伴隨時開啟功能測試或PTI 測試,測試總會失敗即使各個單步測試都通過了.PTI功能表裡有總測試狀態和各個分步測試的狀態, 每一步都有自己的索引編號. 在斷電狀態下只有PTI的總測試狀態會被記錄. PTI測試開啟時資料會記錄一個航程開始trip start事件.7.1 功能測試功能測試是機組的各個部件檢測 (非破壞性檢測).測試是基於GO/NO GO的程式. 所有的測試必須每一步都通過功能測試,測試的結果才是PASS. 功能測試裡的單步也是可以單獨測試的.備註: 如果在壓縮機測試之前壓縮機曲軸箱裡有過多的液體(功能測試的一步), 壓縮機測試將會因為過高的中壓而導致失敗. 這些液體需要蒸發出來. 讓機組在製冷狀態下先運行約10分鐘左右在開啟PTI測試或功能測試.功能測試包含如下項目:1. 初始化 PTI – init2. 控制器測試3. 電源測試4. 蒸發器馬達 (Mevap)5. 冷凝器馬達 (Mcond)6. 加熱器 (Hevap)7. 壓縮機和閥測試 (Vexp, Vhg and Veco)8. 測試結果對於Star Cool CA機組來說下面這些項目會同功能測試一起測試:9. 標準功能測試10. 二氧化碳感測器 t11. 氧氣感測器12. 新風交換馬達13. 真空泵加熱器測試結果14.。

SKiiP603GD172-3DUW V3

SKiiP603GD172-3DUW V3

Fig. 9: Thermal resistance Rth(r-a) versus flow rate V
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
Fig. 6: Transient thermal impedance Zth(j-r)
4
Rev. 3 – 17.10.2012
© by SEMIKRON
SKiiP 603 GD172-3DUW V3
Fig. 7: Transient thermal impedance Zth(r-a)
Fig. 8: Coefficients of thermal impedances

COOL2.1及插件和汉化的下载与安装视频教程

COOL2.1及插件和汉化的下载与安装视频教程

COOL2.1及插件和汉化的下载与安装视频教程录音的第一步当然是装软件了,所以今天我给还没有装软件但是想录歌的朋友简单说说怎么安装录音软件我们推荐大家使用的软件是COOL EDIT 2.1 ,这款软件功能强大,也很专业,翻唱用的最多的就是它了第一步:下载点:/ruanjian/cool2.1.rar (直接点击下载或者用右键另存)第二步:软件下下来后,是一个压缩包,需要解压缩,解压以后是这个样子使用解压软件(win rar/ win zip)来进行解压操作,如果的电脑没有安装解压软件,那么点击这里去下载一个/,解压软件的安装这里就不再叙述,使用下一步下一步操作即可。

第三步:打开《cool2.1的安装破解效果插件程序包》文件夹。

,是这个样子另外有详细的图片安装教程点击进入第四步:打开上图中的“下载安装说明”文档里的内容是:1.运行1cep_v2.0 setup.exe安装Cool Edit Pro v2.0!一般都会安装到默认的路径(备注:安装到专用文件夹也可以,但为了避免不必要的麻烦,最好都用默认路径)2.运行破解注册程序 2cep2reg.exe程序注册,输入注册码(下面有3个注册码,第一个是首选,如果不行,再尝试后面两个):Name: mydajCode: 200-00-NKLYUBNZ后备注册码Name: Peter QuistgardSerial#: 200-00-37YQOQ7LName: marco hardmeierSerial#: 200-00-z3738ej53.运行3cep_v2.1 setup.exe程序安装Cool Edit Pro v2.1!(备注:也就是将2.0版本的升级成2.1版本)4.运行汉化程序 4Cool2chinese 汉化包安装到上面安装程序的路径下注意:在安装过程中每做下一步的时候,把上一步自动打开的cooledit关掉(避免不必要的麻烦)提醒!!!到此,COOL2.1其实就已经安装完成了,但为了后期制作能够达到更好的效果,以下还要安装几个插件。

Insite Gold 版本 2.0.0 安装指南说明书

Insite Gold 版本 2.0.0 安装指南说明书

Insite Gold Version 2.0.0 Setup Guide (QR Code)Document version: 3.9May 17th 2018Created by: Moshe BlitzPrefaceThis document will take you step by step through the setup process of creating new SWAN account with Insite Gold application.Known Limitation1.No support for HD77 camera2.No support for site where IP150 or PCS password was changed from its default when usedwith IP150 version 4.0.43.No support for some models of cellular routers with HDxx camera setup, due to lack of realUPNP support on router or with IP150 due to lack of open ports4.No official support for site with HDxx camera without IP150 / PCS communication device Prerequisite FW upgrade1.Upgrade Panel FW version to the latest version posted on Paradox web site to benefit fromall the functionalities the HD cams can offer.2.Update PCS communication module FW version to the latest version posted on Paradoxweb site.3. Upgrade IP150 to FW version to the latest version posted on Paradox web site (4.30 orlater)4.Make sure to use HD78 camera of version 2.3.17 or later5.Make sure to use HD88 camera of version 1.0 or laterNotes:1.In case of using older HD78 camera version or older HD88 camera version, connectcamera over wired LAN connection and proceed with installation. Once Site is created,upgrade camera to latest version from within the application. Camera can then beswitched to use WiFi connection.2.Once PMH account is sete Babyware version 5.1.0 or later to connect.e Infield version 5.0.23 or later. Any previous versions should not be used.Note that using Infield requires setting port forwarding in the router whenupgrading IP150 version earlier than 4.10IP150 Setup and PrerequisiteConnect using Infield to verify that IP150 Firmware version is 4.20.008 Verify that Panel Firmware version is the latest posted on Paradox website. Upgrade Panel and IP150 firmware version as necessaryNote: Once IP150 is connected to the Internet and to SWAN the “Link” and “Internet” lights on the device are both ON.Some routers may prevent bi-directional communication between IP150 and SWAN server, in such case please verify that the following ports are opened on the outbound direction to allow IP150 to connect with SWAN:1.Port 34782. Port 443. This is HTTPS port and IP150 polling is done over this port3.Port 53 TCP and UDP4.TCP port source: 49152 to 65535 (supports up to 80 TCP connections)5.UDP port source: 49152 to 65535 (supports up to 16 UDP connections)6.Allow ICMP protocol. No port hereHDxx camera Setup and PrerequisiteConnect HDXX camera either using LAN connection (wired) or WiFi connection.System PrerequisiteConnect HDxx camera to the same panel where IP150 or PCS device is connectedNote: Make sure to avoid any of the following actions which mat result with installation failure:1.Do NOT change panel during the installation.2.Do NOT move camera from one panel to another during the installationa.HDxx camera that are already connected to Panel associated with SWAN can’t beassociated with new panel that is not associated yet with SWAN unless HDxxcamera is deleted from DatabaseInstall Insite GoldDownload and install Insite Gold from Google Play or Apple App StoreNew Site setupNote: For Installation with Cameraa.When using iPhone, it is recommended to set the phone using the same WiFinetwork as camerab.Set router’s configuration to UPnP enabled and verify that it is connected directly tothe internet with no additional routers being usedc.Open camera’s Tamperunch Insite Gold2.Click on the menu icon3.Click on New Installation4.Click on Create5.Enter Control Panel Serial Number6.Enter Site ID, Site Email and confirm email7.Check under MODULES LIST section that panel is polling with correct IP150 / PCScommunication device.Note: For site equipped with LAN HDxx cameras, check under MODULES LIST section that cameras are connected and polling.Notes:1.In case no communication device is listed, make sure to check Internet connectionand proceed with installation only after correct communication device is presented.Once connected to the internet, IP150 will have its "internet" light ON to confirms connectivity and polling the SWAN. PCS device will have its STATUS LED ON to confirm its connectivity to cell phone provider.2.In case LAN camera are not listed, make sure to check Internet and bus connection,and proceed with installation only after cameras are presented.8.For site equipped with HDxx WiFi camera, press ADD WIFI CAMERA,Otherwise, For Site equipped only with IP150 / PCS communication device or with HDxx camera connected through LAN, press CREATE NEW SITE9.Press ALLOW once the following message appearsThis action allows storing site’s details on phone’s gallery10.Press ALLOW once the following message appearsThis action allows to present available WiFi network11.Select WiFi network enter password and press CONTINUENote: When using IOS device, you may enter WiFi network name in case it is different than the one listed.12.Hold phone firmly in front of camera’s lens in about 20 cm distance to present QR Code. Asresult, the Right “Network” led will flash rapidly, and camera will set to connectthrough WiFi with SWAN, indicated by having the “Connection led turned on.Note: Continue to present QR Code in front of the camera for about 5 seconds after“Network” LED start to flash rapidly13.Hold Once connected, press CONTINUE14.Once camera is connected, it will appear under Modules List.Press CONFIGURE to set camera and press SAVE15.Press CREATE NEW SITE16.Once the following scree appears, make sure to have access to the email entered as youwill need to activate SWAN token when prompt as part of the setup process.Notes:1.DO NOT PRESS any key until after email is verified.2.DO NOT quite the application and remove it from background17.ACTIVATE Token and new email confirm token activation will arrive18.Select subscription plan and enter payment details19.New created site will appear in site list20.Press site name and enter Master PIN code of the Panel in order to log in.PIN code is the one assigned to User00121.Close camera’s Tamper22.You are set and ready to go。

LITE-ON LTV-214-A-G 光合阈器数据表说明书

LITE-ON LTV-214-A-G 光合阈器数据表说明书

LITE-ON DCC RELEASEPhotocoupler Product Data SheetLTV-214-A-GSpec No.: DS70-2010-0067Effective Date: 12/27/2014Revision: ABNS-OD-FC001/A4PhotocouplersLTV-2X4-G series 1.DESCRIPTION1.1 Features⏹Current transfer ratio (CTR) : MIN. 20% at I F = ±1mA, V CE = 5V)⏹High input-output isolation voltage. (V iso=3,750Vrms)⏹Employs double transfer mold technology⏹Safety approval:UL 1577VDE DIN EN60747-5-5 (VDE 0884-5) ,CSA CA5AFIMKO■RoHS Compliance: All materials be used in device are followed EU RoHS directive (No.2002/95/EC).⏹ESD pass HBM 6000V/MM2000V⏹MSL class11.2 Applications⏹Hybrid substrates that require high density mounting.⏹Programmable controllers⏹System appliances, measuring instruments2. PACKAGE DIMENSIONS2.1 LTV-214-GNotes :1. 3-digit date code.2. Rank shall be or shall not be marked.3. VDE mark only appears on devices ordered “V” option.4. “●” for halogen free option.PhotocouplersLTV-2X4-G series2.2 LTV-224-G2.3 LTV-244-GNotes :1. 3-digit date code.2. Rank shall be or shall not be marked.3. VDE mark only appears on devices ordered “V” option.4. “●” for halogen free option.Photocouplers LTV-2X4-G series3. TAPING DIMENSIONS3.1 P/N : LTV-214-G3.2 P/N : LTV-214-TP1-GDescriptionSymbolDimension in mm (inches)Tape wideW Pitch of sprocket holesP 0Distance of compartmentFP 2Distance of compartment to compartmentP 1Description Symbol Dimension in mm (inch)Tape wideW12±0.3 (0.47) Pitch of sprocket holesP 04±0.1 (0.15) Distance of compartmentF 5.5±0.1 (0.217) P 22±0.1 (0.079) Distance of compartment tocompartmentP 18±0.1 (0.315)PhotocouplersLTV-2X4-G series 3.3P/N :LTV-224-GDescription Symbol Dimension in mm (inch)Tape wide W 12±0.3 (0.47)Pitch of sprocket holes P04±0.1 (0.15)Distance of compartment F 5.5±0.1 (0.217) P22±0.1 (0.079)Distance of compartment tocompartmentP18±0.1 (0.315)Photocouplers LTV-2X4-G series3.4 P/N : LTV-244-G3.5 Quantities per ReelDescription Symbol Dimension in mm (inch)Tape wide W 16±0.3 (0.47) Pitch of sprocket holes P 0 4±0.1 (0.15) Distance of compartment F 7.5±0.1 (0.217) P 2 2±0.1 (0.079) Distance of compartment tocompartmentP 112±0.1 (0.315)Package Type LTV-214-G LTV-224-G LTV-244-G Quantities (pcs)300020002000PhotocouplersLTV-2X4-G series 4. RATING AND CHARACTERISTICS4.1 Absolute Maximum Ratings at Ta=25°CParameter SymbolRatingUnit 214 224 244InputForward Current I F50 mA Reverse Voltage V R 6 V Power Dissipation P 65 mW Pulse Forward Current I FSM 1 AOutputCollector - Emitter Voltage V CEO80 V Emitter - Collector Voltage V ECO7 V Collector Current I C50 mA Collector Power Dissipation P C150 100 mW Total Power Dissipation P tot200 170 mW1. Isolation Voltage V iso3750 V rmsOperating Temperature T opr-55 ~ +110 o CStorage Temperature T stg-55 ~ +150 o CSoldering Temperature T sol260(10s) o C1. AC For 1 Minute, R.H. = 40 ~ 60%Isolation voltage shall be measured using the following method.(1) Short between anode and cathode on the primary side and between collector and emitter on thesecondary side.(2) The isolation voltage tester with zero-cross circuit shall be used.(3) The waveform of applied voltage shall be a sine wave.PhotocouplersLTV-2X4-G series 4.2 ELECTRICAL OPTICAL CHARACTERISTICS at Ta=25°CParameter Symbol Min. Typ. Max. Unit Test Condition InputForward Voltage V F— 1.2 1.4 V I F=±20mATerminal Capacitance C t—60 —pF V=0, f=1KHzOutput Collector Dark Current I CEO——100 nA V CE=20V, I F=0 Collector-EmitterBreakdown VoltageBV CEO80 ——V I C=0.1mA, I F=0 Emitter-CollectorBreakdown VoltageBV ECO7 ——V I E=10μA, I F=0TRANSFER CHARACTERISTICS Collector-EmitterSaturation VoltageV CE(sat)——0.4 V I F±8mA, I C=2.4mA Isolation Resistance R iso5⨯10101⨯1011—ΩDC500V,40 ~ 60% R.H. Floating Capacitance Cf —0.8 1 pF V=0, f=1MHzResponse Time (Rise) tr — 3 18 μs VCE=10V, I C=±2mAR L=100Ω, f=100Hz Response Time (Fall) tf — 4 18 μsPhotocouplers LTV-2X4-G series100%I I CTR FC ⨯=5. RANK TABLE OF CURRENT TRANSFER RATIO CTRModel No.CTR RankMin Max ConditionLTV-214-G0 20 400 I F =±1mA, V CE =5V, Ta=25o CA50 250 AK 100 200 B 100 400 GR 100 300 I F =±5mA, V CE =5V, Ta=25o CLTV-224-G LTV-244-G20 400I F =±1mA, V CE =5V, Ta=25o CA5 100 300 GB100400I F =±5mA, V CE =5V, Ta=25o CPhotocouplersLTV-2X4-G series-3.2-2.8-2.4-2.0-1.6-1.2-0.8-0.40.1110100Forward Current, I F (mA)F o r w a r d V o l t a g e T e m p e r a t u r e C o e f f c i e n t △V F / △T a (m V /o C )11010010000.51 1.52 2.53Pulse Forward Voltage, V FP (V )P u l s e F o r w a r d C u r r e n t , I FP ( m A )Pulse Widths ≦10 usRepetitive Frequency = 100Hz Ta = 25 ℃6. CHARACTERISTICS CURVESFigure 1. Collector Power Dissipation vs. Ambient Temperature Figure 2. Forward Current vs. Ambient TemperatureFigure 3. Forward Current vs. Forward Voltage Figure 4. Forward Voltage Temperature Coefficient vs.Forward CurrentFigure 5. Pulse Forward Current vs. Duty Cycle RatioDuty RatioPulse width <= 100 sP u l s e F o r w a r d C u r r e n t I (m A )FP 10100001001000Ta=25 CFigure 6. Pulse Forward Current vs. Pulse Forward0102030405060-25255075100Ambient Temperature,Ta (℃)F o r w a r d C u r r e n t , I F (m A )20406080100120140160-25255075100125Ambient Temperature,Ta(℃)C o l l e c t o r P o w e r D i s s i p a t i o n , P c (m W )LTV-214LTV-224LTV-244Forward Voltage ( Volts )F o r w a r d C u r r e n t ( m A )Photocouplers LTV-2X4-G series01020304050510Collector-Emitter Voltage, V CE ( V )C o l l e c t o r C u r r r e n t , I c ( m A )50mA30mA20mA10mAI =5mAP (Max)=150mVVce 48VVce 24VVce 10VVce 5VFigure 7. Collector-Emitter Saturation Voltage vs. ForwardCurrent 00.511.522.533.544.5502468101214161820Forward Current, I F(mA)C o l l e c t -E m i t t V o l t a g e , V C E (V )10mA7mA0.5mA1mA3mA5mAFigure 8. Collector Current vs. Collector-EmitterFigure 9. Collector Current vs. Small Collector-EmitterVoltage 0510152025303540455000.51Collector-Emitter Voltage, V CE( V )C o l l e c t o r C u r r r e n t , I c ( m A )50mA30mA20mA10mA5mAI F=2mAFigure 10. Normalzied CTR vs. Forward CurrentFigure 11. Collector Dark Current vs. Ambient Temperature Figure 12. Current Transfer Ratio vs. ForwardCurrent11010010000.1110100C T R -C u r r e n t T r a n s f e r R a t i o -%I F -Forward Current -mA10V V CE = 0.4V5V0.11100.1110100N o r m a l a i z e d C T RI F -Forward Current -mANormalized to I F = 1mA, V CE = 5V T A =25o CPhotocouplers LTV-2X4-G series-8-6-4-2110100Frequency ( kHz )V O ( d b )Vcc=5V Ic=2mATa=25CR =100Ω1K Ω0.1110100-60-40-20020406080100120C o l l e c t o r C u r r e nt , I C (m A )A m b i e n t Te m p e r a t u r e , TA (o C)I F = 0.5m A1m A 25m A20m A5m AV CE = 5V0.1110100-55-202550100t O Ntst O F FA mb i e n t t e mp e r a t u r e Ta (C)S w i t c h i n g t i m e (Figure 13. Collector-Emitter Saturation Voltage vs. Ambient TemperatureFigure 14. Collector Current vs. Ambient TemperatureFigure 15. Switching Time vs. Load Resistance 0.11101001000110100Load Resistance, R L ( KO)S w i t c h i n g T i m e ( µS )T offT sT onTa = 25 ℃Vcc = 5V R L = 1.9k ΩFigure 16. Switching Time vs. Ambient TemperatureFigure 17. Frequency Response0.000.020.040.060.080.100.120.140.160.18-3054075110Ambinet Temperature, Ta (o C)C o l l e c t o r -E m i t t e r S a t u r a t i o n V o l t a g e (V )I =8mAI =2.4mAI =20mA I =1mAI =1mA I =0.2mAPhotocouplers LTV-2X4-G series7. SWITCHING TIME TEST CIRCUITR Lt t ts0.5V4.5V CEI F V Vcc ON OFF8. TEMPERATURE PROFILE OF SOLDERING 8.1 IR Reflow soldering (JEDEC-STD-020C compliant)One time soldering reflow is recommended within the condition of temperature and time profile shown below. Do not solder more than three times.Profile itemConditionsPreheat- Temperature Min (T Smin ) - Temperature Max (T Smax ) - Time (min to max) (ts) 150˚C 200˚C 90±30 secSoldering zone - Temperature (T L ) - Time (t L )217˚C 60 ~ 100 secPeak Temperature (T P ) 260˚C Ramp-up rate 3˚C / sec max. Ramp-down rate3~6˚C / secPhotocouplers LTV-2X4-G series60 ~ 120 sec 25 C150 C200 C260 C217 C60-100 sec Time (sec)T e m p e r a t u r e ( C )20 secTsmax ts (Preheat)tL (Soldering)Tsmin TL TP Ramp-downRamp-up8.2 Wave soldering (JEDEC22A111 compliant)One time soldering is recommended within the condition of temperature. Temperature: 260+0/-5˚C Time: 10 sec.Preheat temperature:25 to 140˚C Preheat time: 30 to 80 sec .PhotocouplersLTV-2X4-G series 8.3 Hand soldering by soldering ironAllow single lead soldering in every single process. One time soldering is recommended.Temperature: 380+0/-5˚CTime: 3 sec max.9. RRECOMMENDED FOOT PRINT PATTERNS (MOUNT PAD)Unit: mmP/N : LTV-214 P/N : LTV-224P/N : LTV-244PhotocouplersLTV-2X4-G series 10. Notes:⏹LiteOn is continually improving the quality, reliability, function or design and LiteOn reserves the right to make changeswithout further notices.⏹The products shown in this publication are designed for the general use in electronic applications such as office automationequipment, communications devices, audio/visual equipment, electrical application and instrumentation.⏹For equipment/devices where high reliability or safety is required, such as space applications, nuclear power controlequipment, medical equipment, etc, please contact our sales representatives.⏹When requiring a device for any ”specific” application, please contact our sales in advice.⏹If there are any questions about the contents of this publication, please contact us at your convenience.⏹The contents described herein are subject to change without prior notice.⏹Immerge unit’s body in solder paste is not recommended.。

lg 9000btu 2-in-1 mini split system technical data

lg 9000btu 2-in-1 mini split system technical data

Cooling Capacity (Min.‐Rated‐Max., Btu/h)Heating Capacity (Min.‐Rated‐Max., Btu/h)Max. Heating Capacity at 17°F (Btu/h)Max. Heating Capacity at 5°F (Btu/h)Max. Heating Capacity at ‐4°F (Btu/h)Cooling COP @95°F (Rated)Heating COP @47°F (Rated)Refrigerant Charge (lbs.)Liquid Line Connection (in., O.D.)Vapor Line Connection (in., O.D.)Maximum Total Piping² (ft.)Min. / Max. ODU to IDU Piping (ft.)Piping Length (no add’l refrigerant, ft.)Maximum Elevation between ODU and IDU (ft.)Maximum Elevation between IDU and IDU (ft.)For: File Resubmit Approval OtherJob Name/Location:Date:PO No.:Architect: GC:Engr: Mech:Rep:(Company)(Project Manager)Tag No:Features:For a complete list of available accessories, contact your LG representative.For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /Optional Accessories:Performance:Electrical:Power Supply (V/Hz/Ø)1 MOP (A)MCA (A)Recommended Fuse Size (A)Cooling Rated Amps (A)Heating Rated Amps (A)Compressor (A)Fan Motor (A)Locked Rotor Amps (A) 208‐230V, 60, 1Page 1 of 2Cooling (°F DB)Heating (°F WB)14 to 118‐4 to +64Operating Range:Unit Data:Type Quantity Oil / TypeTwin Rotary1FVC68DCompressor: PI‐485 ‐ PMNFP14A1 MultiSITE Comm. Mgr. ‐ PBACNBTR0A AC Smart 5 ‐ PACS5A000 ACP 5 ‐ PACP5A000 Power Distribution Indicator (PDI) Premium ‐ PQNUD1S41 Mobile LGMV ‐ PLGMVW100 Piping:• Auto operation • Auto restart• Inverter (variable speed compressor)• Defrost / Deicing • Restart delay (three [3] minutes)• Self diagnosis • Soft start• Low ambient cooling down to 14°FCooling Nominal Test Conditions:Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WBHeating Nominal Test Conditions:Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WBNotes:1. Acceptable operating voltage: 187V ‐ 253V.2. Piping lengths are equivalent.3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.4. All power / communication cable to be minimum 14 AWG, 4‐conductor, stranded, shielded or unshielded wire, and must comply with applicable local and national codes. If shielded, the wire must be grounded to the chassis at the outdoor unit only.5. Power wiring size must comply with the applicable local and national codes.6. This data is rated 0 ft. above sea level, with 0 ft. level difference between outdoor and indoor units, and the following refrigerant pipe lengths: LMU183HV: 16.4 ft. x 2 = 32.8 ft. LMU243HV: 16.4 ft. x 3 = 49.2 ft. LMU303HV: 16.4 ft. x 4 = 65.6 ft. LMU363HV: 16.4 ft. x 4 = 65.6 ft.All capacities are net with a combination ratio between 95 ‐ 105%.7. Must follow installation instructions in the applicable LG installation manual.8. Refer to the Combintion Data Manual for combination capacity tables.9. See the Performance Data Manual for sensible and latent capacities.Refrigerant Type Refrigerant ControlSound Pressure (Cool / Heat) ±1 dB(A)3Net / Shipping Weight (lbs.)Heat Exchanger CoatingMinimum No. of Indoor Units Maximum No. of Indoor UnitsType QuantityMotor / DriveMax. Airflow Rate (CFM)Propeller1Brushless Digitally Controlled/DirectFan:9.8 / 82.049.224.6MOP ‐ Maximum Overcurrent ProtectionMCA ‐ Minimum Circuit AmpacityODU = Outdoor UnitIDU = Indoor UnitR410A EEV Gold Fin ™2Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR ® criteria. Ask your contractor for details or visit .(ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.)8,400~24,000~25,0003.7201/4 x 350 / 54101.4 / 110.21,7663.970.4010,080~24,600~29,000Drain Pan Heater - PQSH1203230.02016.013.015,40013.098.44.2SB_MultiF_LMU243HV_2023_05_31_064315Low Ambient Baffle Kit(Cooling operation to -4°F) -ZLABGP03A18,4003/8 x 316.012.021,4003For continual product development, LG reserves the right to change specifications without notice.© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /Page 2 of 2Job Name/Location:Tag No.:Date:PO No.:SB_MultiF_LMU243HV_2023_05_31_064315。

COOL2.1及插件和汉化的下载与安装视频教程

COOL2.1及插件和汉化的下载与安装视频教程

COOL2.1及插件和汉化的下载与安装视频教程录音的第一步当然是装软件了,所以今天我给还没有装软件但是想录歌的朋友简单说说怎么安装录音软件我们推荐大家使用的软件是COOL EDIT 2.1 ,这款软件功能强大,也很专业,翻唱用的最多的就是它了第一步:下载点:/ruanjian/cool2.1.rar (直接点击下载或者用右键另存)第二步:软件下下来后,是一个压缩包,需要解压缩,解压以后是这个样子使用解压软件(win rar/ win zip)来进行解压操作,如果的电脑没有安装解压软件,那么点击这里去下载一个/,解压软件的安装这里就不再叙述,使用下一步下一步操作即可。

第三步:打开《cool2.1的安装破解效果插件程序包》文件夹。

,是这个样子另外有详细的图片安装教程点击进入第四步:打开上图中的“下载安装说明”文档里的内容是:1.运行1cep_v2.0 setup.exe安装Cool Edit Pro v2.0!一般都会安装到默认的路径(备注:安装到专用文件夹也可以,但为了避免不必要的麻烦,最好都用默认路径)2.运行破解注册程序 2cep2reg.exe程序注册,输入注册码(下面有3个注册码,第一个是首选,如果不行,再尝试后面两个):Name: mydajCode: 200-00-NKLYUBNZ后备注册码Name: Peter QuistgardSerial#: 200-00-37YQOQ7LName: marco hardmeierSerial#: 200-00-z3738ej53.运行3cep_v2.1 setup.exe程序安装Cool Edit Pro v2.1!(备注:也就是将2.0版本的升级成2.1版本)4.运行汉化程序 4Cool2chinese 汉化包安装到上面安装程序的路径下注意:在安装过程中每做下一步的时候,把上一步自动打开的cooledit关掉(避免不必要的麻烦)提醒!!!到此,COOL2.1其实就已经安装完成了,但为了后期制作能够达到更好的效果,以下还要安装几个插件。

3SK297资料

3SK297资料

3SK297Silicon N-Channel Dual Gate MOS FETADE-208-3891st. EditionApplicationUHF / VHF RF amplifierFeatures• Low noise figure.NF = 1.0 dB typ. at f = 200 MHz• Capable of low voltage operationOutline3SK2972Absolute Maximum Ratings (Ta = 25°C)ItemSymbol Ratings Unit Drain to source voltage V DS 12V Gate 1 to source voltage V G1S ±8V Gate 2 to source voltage V G2S ±8V Drain currentI D 25mA Channel power dissipation Pch 150mW Channel temperature Tch 150°C Storage temperatureTstg–55 to +150°CAttention:This device is very sensitive to electro static discharge.It is recommended to adopt appropriate cautions when handling this transistor.3SK2973Electrical Characteristics (Ta = 25°C)ItemSymbol Min Typ Max Unit Test conditions Drain to source breakdown voltageV (BR)DSX 12——V I D = 200 µA , V G1S = –3 V,V G2S = –3 VGate 1 to source breakdown voltageV (BR)G1SS ±8——V I G1 = ±10 µA, V G2S = V DS = 0Gate 2 to source breakdown voltageV (BR) G2SS ±8——V I G2 = ±10 µA, V G1S = V DS = 0Gate 1 cutoff current I G1SS ——±100nA V G1S = ±6 V, V G2S = V DS = 0Gate 2 cutoff current I G2SS ——±100nA V G2S = ±6 V, V G1S = V DS = 0Drain currentI DS(on)0.5—10mA V DS = 6 V, V G1S = 0.75V,V G2S = 3 VGate 1 to source cutoff voltage V G1S(off)0—+1.0V V DS = 10 V, V G2S = 3V,I D = 100 µAGate 2 to source cutoff voltage V G2S(off)0—+1.0V V DS = 10 V, V G1S = 3V,I D = 100 µAForward transfer admittance |y fs |1620—mS V DS = 6 V, V G2S = 3V,I D = 10 mA, f = 1 kHz Input capacitance Ciss 2.4 2.9 3.4pF V DS = 6 V, V G2S = 3V,I D = 10 mA, f = 1 MHzOutput capacitanceCoss 0.8 1.0 1.4pF Reverse transfer capacitance Crss —0.0230.04pF Power gain PG 2225—dB V DS = 6 V, V G2S = 3V,I D = 10 mA, f = 200 MHz Noise figure NF — 1.0 1.8dB Power gain PG 1215—dB V DS = 6 V, V G2S = 3V,I D = 10 mA, f = 900 MHz Noise figure NF — 3.2 4.5dB Noise figureNF—2.83.5dBV DS = 6 V, V G2S = 3V,I D = 10 mA, f = 60 MHz Note:Marking is “ZP–”3SK29743SK29753SK29763SK29773SK29783SK2979S Parameter (V DS = 6 V, V G2S = 3 V, I D = 10 mA, Z O = 50 )Freq.S11S21S12S22(MHz)MAG.ANG.MAG.ANG.MAG.ANG.MAG.ANG.500.994–5.8 2.04173.60.0011676.90.993–2.21000.993–11.0 2.02167.40.0013285.70.993–4.51500.986–16.8 2.00161.50.0022978.20.991–6.42000.980–22.5 1.98155.50.0031373.50.990–8.52500.973–27.8 1.94149.60.0042768.70.987–10.53000.950–33.0 1.90142.60.0047363.90.985–12.53500.936–38.3 1.86137.10.0053664.30.982–14.44000.924–43.4 1.83131.60.0056164.50.979–16.24500.912–48.0 1.77126.80.0056260.90.975–18.25000.893–52.5 1.71121.00.0064053.50.971–20.25500.874–57.3 1.67115.50.0063849.30.967–22.06000.859–62.0 1.64111.10.0064749.00.964–23.96500.846–66.1 1.58106.70.0066750.20.960–25.87000.829–69.8 1.50102.10.0069449.30.955–27.67500.810–74.2 1.4697.10.0066146.60.952–29.48000.802–78.0 1.4492.70.0061843.70.948–31.28500.791–81.6 1.3888.90.0062244.70.944–33.29000.778–84.6 1.3484.20.0061543.60.940–35.19500.756–88.5 1.3080.20.0057645.10.935–36.810000.751–92.21.2675.90.0056240.70.932–38.5Unit: mm 元器件交易网Cautions 1.Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent,copyright, trademark, or other intellectual property rights for information contained in this document.Hitachi bears no responsibility for problems that may arise with third party’s rights, includingintellectual property rights, in connection with use of the information contained in this document.2.Products and product specifications may be subject to change without notice. Confirm that you havereceived the latest product standards or specifications before final design, purchase or use.3.Hitachi makes every attempt to ensure that its products are of high quality and reliability. However,contact Hitachi’s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation,traffic, safety equipment or medical equipment for life support.4.Design your application so that the product is used within the ranges guaranteed by Hitachi particularlyfor maximum rating, operating supply voltage range, heat radiation characteristics, installationconditions and other characteristics. Hitachi bears no responsibility for failure or damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Hitachi product does not cause bodily injury, fire or other consequential damage due to operation of the Hitachi product.5.This product is not designed to be radiation resistant.6.No one is permitted to reproduce or duplicate, in any form, the whole or part of this document withoutwritten approval from Hitachi.7.Contact Hitachi’s sales office for any questions regarding this document or Hitachi semiconductorproducts.Hitachi, Ltd.Semiconductor & Integrated Circuits.Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan Tel: Tokyo (03) 3270-2111 Fax: (03) 3270-5109Copyright ' Hitachi, Ltd., 1999. All rights reserved. Printed in Japan.Hitachi Asia Pte. Ltd.16 Collyer Quay #20-00Hitachi Tower Singapore 049318Tel: 535-2100Fax: 535-1533URL NorthAmerica : http:/Europe : /hel/ecg Asia (Singapore): .sg/grp3/sicd/index.htm Asia (Taiwan): /E/Product/SICD_Frame.htm Asia (HongKong): /eng/bo/grp3/index.htm Japan : http://www.hitachi.co.jp/Sicd/indx.htmHitachi Asia Ltd.Taipei Branch Office 3F, Hung Kuo Building. No.167, Tun-Hwa North Road, Taipei (105)Tel: <886> (2) 2718-3666Fax: <886> (2) 2718-8180Hitachi Asia (Hong Kong) Ltd.Group III (Electronic Components)7/F., North Tower, World Finance Centre,Harbour City, Canton Road, Tsim Sha Tsui,Kowloon, Hong Kong Tel: <852> (2) 735 9218Fax: <852> (2) 730 0281 Telex: 40815 HITEC HXHitachi Europe Ltd.Electronic Components Group.Whitebrook ParkLower Cookham RoadMaidenheadBerkshire SL6 8YA, United KingdomTel: <44> (1628) 585000Fax: <44> (1628) 778322Hitachi Europe GmbH Electronic components Group Dornacher Stra§e 3D-85622 Feldkirchen, Munich Germany Tel: <49> (89) 9 9180-0Fax: <49> (89) 9 29 30 00Hitachi Semiconductor(America) Inc.179 East Tasman Drive,San Jose,CA 95134Tel: <1> (408) 433-1990Fax: <1>(408) 433-0223For further information write to:。

LG 7.3 cu. ft. Rear Control Top Load Dryer with Tu

LG 7.3 cu. ft. Rear Control Top Load Dryer with Tu

• FlowSense™ Duct Clogging Indicator • LoDecibel™ Quiet Operation• LG ThinQ® Technology (Wi-Fi)DIMENSIONS / CLEARANCESINSTALLATION SPACING FOR CABINETFor cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.VENTING THE DRYER • I f connecting to existing ductwork, make sure it is suitable and clean before installing the dryer.• Venting must conform to local building codes.• Gas dryers MUST exhaust to the outdoors.• U se only 4-inch (10.2 cm) rigid, semi-rigid or flexible metal ductwork inside the dryer cabinet and for venting outside.• T he exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer.• R igid, semi-rigid or flexible metal ducting is recommended for use between the dryer and the wall. All non-rigid metal transition duct must be UL-listed. Use of other materials for transition duct could affect drying time.• D uctwork is not provided with the dryer. You should obtain the necessary ductwork locally.The vent hood should have hinged dampers to prevent backdraft when the dryer is not in use.• The total length of flexible metal duct must not exceed 8 ft. (2.4 m).NOTE:• Deduct 6 ft. (1.8 m) for each additional elbow. Do not use more than four 90° elbows.Wall Cap TypeNumber of90° ElbowsMaximum lengthof 4-inch diameterrigid metal ductRecommended065 ft. (19.8 m)155 ft. (16.8 m)247 ft. (14.3 m)336 ft. (11.0 m)428 ft. (8.5 m)Use only for short run installations 055 ft. (16.8 m)147 ft. (14.3 m )241 ft. (12.5 m)330 ft. (9.1 m)422 ft. (6.7 m)4"(102 mm)4"(102 mm)2 1/2"(635 mm)DUCTWORK ROUTING AND CONNECTING DUCTWORKNOTE:Follow the guidelines below to maximize drying performance and reduce lint buildup and condensation in the ductwork. Ductwork and fittings are NOT included and must be purchased separately.• Use 4-inch (10.2 cm) diameter rigid, semi-rigid or flexible metal ductwork.• The exhaust duct run should be as short as possible.• Use as few elbow joints as possible.• The male end of each section of exhaust duct must point away from the dryer.• Use duct tape on all duct joints.• I nsulate ductwork that runs through unheated areas in order to reduce condensation and lint buildup on duct surfaces.• I ncorrect or inadequate exhaust systems are not covered by the dryer warranty. Dryer failures or service requiredbecause of such exhaust systems will not be covered by the dryer warranty.7"* (17.8 cm)(CORRECT VENTING * Required spacingPower cord location (gas models)Water inlet valve (on some models)Exhaust ductoutlet Terminal blockaccess panel (electric models)Gas connection location(gas models)7"* (17.8 cm)7"* (17.8 cm)5"*(12.7 cm)1"(2.5 cm)1"*(2.5 cm)1"(2.5 cm)29 1/2"(75.0 cm)27"(68.6 cm)4"(10.2 cm)4"(10.2 cm)CORRECT VENTING© 2022 LG Electronics USA, Inc. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. All other product and brand names aretrademarks or registered trademarks of their respective owners. Design, features and specifications are subject to change without notice. Non-metric weights and measurements are approximate. Some features may require Internet access. Content and services may vary by product and are。

相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档