华为BSC6900和爱立信MGW光口MSP对接总结

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

华为BSC6900和爱立信MGW光口MSP对接总结
1 背景
华为BSC6900部分场景下A接口板不支持单端倒换只支持双端倒换,而爱立信MGW部分场景接口板下不支持双端倒换,两端采用MSP对接时,会因两端支持模式不一样,无法正常对接,需要规避两端的差异。

2 华为BSC6900 MSP支持情况
华为BSC6900 A接口单端倒换的支持存在如下限制
当POUc作为A接口板,所在的插框背板版本为A或者B时,在BM/TC合一场景并且上面承载有七号信令时,不支持MSP 1+1单端倒换。

OIUa单板作为A接口板,在BM/TC合一场景并且上面承载有七号信令时,不支持MSP 1+1单端倒换。

可使用如下方法查询插框背板版本(使用DSP BRDVER命令查询SCU单板即可查到背板版本)
+++ bsc183 2010-11-02 11:53:28
O&M #14450
%%DSP BRDVER: SRN=0, SN=6;%%
RETCODE = 0 执行成功.
单板版本信息(SCU)
-----------------
框号 = 0
槽位号 = 6
子系统号 = 0
单板类型 = SCUa
逻辑功能类型 = MAC Switching
主机系统软件版本号 = V900R011C00SPC720
FLASH主机软件版本号 = V900R011C00SPC720
FLASH中备区软件版本号 = V900R011C01SPC500
FLASH中BIOS0软件版本号 = 224
FLASH中BIOS1软件版本号 = 224
单板BIOS软件版本号 = 224
背板版本号 = VER.C
(结果个数 = 1)
--- END
附:BSC6900 A接口板处理信令时部分场景不能配置为单端倒换的原因:
由上图可以看出,信令面数据是不能进行双发选收,如果接口板处理信令就不能配置为单端倒换。

在BM/TC合一情况下A接口板处理MTP2信令,所以不能配置为单端倒换模式。

在BM/TC分离情况下,A接口板没有处理信令,MTP2信令是在BM框的CIU(Ater接口板)上处理的,所以可以配置为单端/双端倒换模式;Ater口和Abis口光口板是处理7号信令及LAPD信令等,所以必须支持双端倒换模式。

3 爱立信MGW MSP支持情况
说明:以下说明仅供参考,和爱立信对接时最好和客户及对端核实确认。

爱立信MGW针对ETSI、TCC、ANSI不同市场,APS(MSP)有不同的支持能力,其中
和华为相关的是ETSI。

目前爱立信MGW主用版本为R5.1; R6.1版本会对支持能力增强(目前应该还没有商用)。

爱立信MGW 光口接口板有三种类型的单板:ET-MC41、ET-C41、ET-MF4,这三种单板类型中,其中ET-C41可能是TDM接口单板,其他为ATM接口单板。

针对ETSI支持情况如下。

附:爱立信对MGW APS支持情况描述:
In M-MGw R5.1 TDM and ATM ET boards supports MSP1+1 as follows:
ETSI:
- Unidirectional, non-revertive Multiplex Section Protection (MSP) on ET-MC41, ET-C41 and ET-MF4 is based on ITU-T G.841.
- Bi-directional (non optimized) revertive Multiplex Section Protection(MSP) on ET-MF4 is based on ITU-T G.841.
TTC:
- Bi-directional MSP 1+1 (optimized) as specified by ITU-T G.841 Annex B
ANSI:
- Unidirectional, non-revertive Multiplex Section Protection (MSP) on ET-MC41, ET-C41 and ET-MF4 is based on ITU-T G.841.
The following requirement is a candidate for the M-MGw R6.1:
- Bidirectional 1+1 MSP for the ANSI (according to ANSI T1.105.01 and Telcordia GR-253) and ETSI market (according to ITU-T recommendation G.841) for all boards with MSP support.
We are at the moment using ETSI standard ( and we cannot change it to TTC of course ) The issue was solved in Egypt on the Huawey side since also in that case the RNC was working fine I mean it was possible to configure it using Bi-directional ( non-optimized ) in the BSC ther's not this possibility.
In my opinion the BSC needs to be alligned with the ETSI standard and once again Huawey is aware of this problem and solved by some kind of patch on their node ( in Egypt );
综述,华为BSC6900部分场景下A口只能配置为双端倒换,但是爱立信MGW只支持单端倒换,所以,这种场景下,需要其他方案规避两端配置上的差异。

4 解决对接方案
适用场景:华为A接口板因章节2中限制不支持单端倒换,对端不支持双端倒换。

4.1 方案一: BSC6900光接口(OIUa/POUc)承载用户面数据流,电接口板
(EIUa)承载信令面
BM/TC合一情况,A口光接口板只承载用户面数据流,支持MSP单/双端倒换。

可以将BSC6900 A口光接口板和对端MGW光接口板MSP采用单端倒换模式对接。

4.2 方案二:华为BSC6900和爱立信MGW之间使用光传输设备适配
BSC6900采用BM/TC合一情况,只能配置为双端倒换;对端MGW只支持单端倒换;使用光传输设备进行适配,BSC6900 A口光接口板和光传输设备MSP采用双端倒换对接;光传输设备和MGW之间MSP采用单端倒换对接。

光传输设备要求:光口制式为SDH,支持MSP 1+1保护,倒换模式支持单端倒换模式和双端倒换两种模式。

4.3 方案三:BSC6900 机框组合模式配置为BM/TC分离模式
BM/TC分离模式,A口光接口板MSP支持单端/双端倒换;两端APS采用单端倒换模式对接。

4.4 方案四:华为BSC6900和爱立信MGW采用单板独立模式对接
华为BSC6900和爱立信MGW对接不采用MSP,两端各使用一块A光接口板对接,而采用非主备方式。

将信令负荷分担到多块接口板上。

4.5 方案五:对端设备支持双端倒换
如果对端支持双端倒换,两端采用MSP双端倒换对接。

对端双端倒换要求:基于G.841非双端优化协议。

相关文档