中国版简明ICF核心要素量表在社区脑卒中康复中应用的可行性研究
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
中国版简明ICF核心要素量表在社区脑卒中康复中应用的可
行性研究
徐国会;俞卓伟;徐悦莹;郑洁皎
【期刊名称】《老年医学与保健》
【年(卷),期】2011(17)2
【摘要】Objective To explore the application and feasibility of brief ICF core sets for Chinese stroke patients in community-based rehabilitation. Method One hundred and forty-six community stroke patients were measured with brief ICF Core Sets for Chinese stroke patients, the NIH Stroke Scale (NIHSS) , Barthel Index (BI) and SF-36. Repetition reliability, internal consistency and face validity were analyzed with Kappa test, Conbach α index and Pearson correlation analysis respectively in the process of PNF technique for six months. Result The brief ICF Core Sets for Chinese stroke patients had very good repetition reliability among components of body function, body structure, activity and participation with Kappa=0.782-0.935 and environment factor with Kappa=0.578-
0.931before PNF intervention and with Kappa = 0 .787-0.965 and Kappa = 0.608-0.969 after intervention respectively. Good internal consistency existed in body function , activity and participation and environment factor with α= 0.774-0.926 before PNF intervention and with α= 0.786-0.953 after PNF rehabilitation. There was concurrent validity for the ICF components with BI , NIHSS and SF-36. Correlation coefficient between
ICF stroke scales and NIHSS, BI and SF-36 were 0 . 848,0 . 867,0.798 before rehabilitation intervention and 0.854,0 . 879,0 . 832 after PNF intervention respectively . Conclusion Brief ICF core sets evaluation was clinically feasible for stroke community-based rehabilitation with good reliability and validity, and could be further applied and promoted.%目的探讨中国版脑卒中简明ICF核心要素鼍表(以下简称中国版ICF简表)在社区脑卒中康复中应用的可行性.方法 146例社区脑卒中患者,接受以本体感觉神经肌肉促进疗法(PNF)为主的康复治疗6个月.按照中国版ICF简表、美国国立卫生研究院卒中量表(NIHSS)、Barthel指数(BI)和SF-36的规则进行治疗前后评定.效度研究采用校标效度,以Spearman相关性判断中国版ICF简表与NIHSS、BI和SF-36的相关性大小.信度研究采用重测信度和内部一致性的分析方法,分别以Kpppa检验和Cronbach α表示.结果中国版ICF简表的四个成份中,身体结构、身体功能,活动与参与的Kappa值治疗前后分别在0.782-0.935和0.787-0.965之间(P<0.01);环境因素的Kappa值治疗前后分别在0.578-0.931和0.608-0.969(P<0.01)之间,有较为良好的重测信度.身体功能、活动与参与和环境因素有较好的内部一致性,α值治疗前后分别在0.774-0.926和0.786-0.953之间.治疗前后该量表与NIHSS,BI,SF-36相关系数分别为0.848,0.867,0.798(P<0.01)及0.854,0.879,0.832(P<0.01),提示ICF与NIHSS,BI,SF-36有较好的共同效度.结论在社区脑卒中康复治疗前后,中国版ICF简表具有较高的信度和效度,可以进一步推广应用.
【总页数】4页(P88-91)
【作者】徐国会;俞卓伟;徐悦莹;郑洁皎
【作者单位】200040上海,复旦大学附属华东医院康复医学科;200040上海,复旦大学附属华东医院老年医学研究所;200040上海,复旦大学附属华东医院康复医学科;200040上海,复旦大学附属华东医院康复医学科
【正文语种】中文
【中图分类】R493
【相关文献】
1.糖尿病简明ICF核心要素量表在糖尿病肾病血液透析患者中应用的信效度分析[J], 邱利;薛梅
2.中国版脑卒中简明ICF核心要素量表在康复中的应用 [J], 郝又国;陆伟伟;施海燕;李旭
3.中国版脑卒中简明ICF核心要素量表的信度与效度研究 [J], 郭铁成;陈小红;卫小梅
4.中国版脑卒中简明ICF核心要素量表在老年人群中的效度 [J], 曹蓉;许光旭
5.在社区脑卒中康复中采用中国版简明ICF核心要素量表的可行性分析 [J], 何青艳
因版权原因,仅展示原文概要,查看原文内容请购买。