DSM2180F3V-15T6;DSM2180F3V-15K6;中文规格书,Datasheet资料

合集下载

Moxa MPC-2150系列15英寸面板计算机说明书

Moxa MPC-2150系列15英寸面板计算机说明书

P/N: 1802021500010 *1802021500010*MPC-2150 SeriesQuick Installation GuideEdition 1.0, October 2015Technical Support Contact Information/supportMoxa Americas:Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Europe:Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa Asia-Pacific:Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Moxa India:Tel: +91-80-4172-9088 Fax: +91-80-4132-10452015 Moxa Inc. All rights reserved.OverviewThe MPC-2150, 15-inch panel computer, with 3rd generation Intel® Core™ processor delivers a reliable, durable, high-performance platform of wide versatility of use in industrial environments.The MPC-2150 series panel computers are designed with a wide -40 to 70°C temperature range, and come with a patented fanless, streamlined housing designed for highly efficient heat dissipation, making this computer one of most reliable industrial platforms available for harsh, hot, outdoor environments, such as are found at oil and gas fields and on drilling platforms.The MPC-2150 also features a 1,000-nit LCD panel with a sunlight readable and projected capacitive glove-friendly multi-touch screen, providing an excellent user experience for outdoor applications. Package ChecklistBefore installing the MPC-2150, verify that the package contains the following items:•MPC-2150 panel computer• 1 2-pin terminal block for DC power input•SSD/HDD installation kit•Documentation and driver DVD•Quick installation guide (printed)•Warranty cardNOTE: Please notify your sales representative if any of the above items are missing or damaged.Hardware InstallationFront ViewBottom ViewSavvyTouch Display Control ButtonsThe following table describes the SavvyTouch display controls on the front surface of the MPC-2150. These intelligent controls will light up with a simple hand-wave above the area of the screen where they are located.Connector DescriptionAC/DC Power InputThe MPC-2150 allows using either an AC or DC power input. When using AC power, use the standard C14 AC inlet. When using DC power, use at least a 60 W power adapter through the 2-pin terminal block in the accessories package. The figure shows the MPC-2150’s DC pin assignments.Extending the DisplayThe MPC-2150 comes with both standard VGA (DB15) and DVI-D (DB29) interfaces (located on the bottom of the shell) which may be used to simultaneously extend the display across two monitors. Connecting to a Keyboard and Mouse The MPC-2150 Series comes with two PS/2 connectors located on the bottom surface, for connecting a keyboard and a mouse.Serial PortsThe MPC-2150 offers two software-selectable RS-232/422/485 serial ports over a DB9 connector. Refer to the MPC-2150 User’s Manual for serial port configuration details. The pin assignments for the ports are shown in the table below:Ethernet PortsThe pin assignments for the two Fast Ethernet 100/1000 Mbps RJ45 ports are shown in the following table:Refer to the following table for a description of the LAN indicators: LAN(on connectors) Green 100 Mbps Ethernet modeYellow 1000 Mbps (Gigabit) Ethernet mode OffNo activity / 10 Mbps Ethernet modeAudio InterfaceThe MPC-2150 comes with line-in and line-out audio jacks, allowing users to connect a speaker system, an earphone, or a microphone.USB PortsFour USB 2.0 ports are available on the bottom surface. Use these ports to connect mass storage drives and other peripherals.Installing a SATA HDD or SSDThe MPC-2150 comes with an HDD/SSD installation kit accessory. To install the 2.5-inch SATA storage, follow these instructions. For better system reliability, we suggest using a solid state disk (SSD). A list of compatible SSD models is available on Moxa’s website.e 4 screws to fasten the HDD/SSD to the HDD/SSD bracket.2.Remove the 2 screws holding the HDD/SSD cover to the MPC-2150.3.Insert the HDD/SSD (with the bracket) into the HDD/SDD slot. Notedthat the latch on HDD/SSD bracket should be released when pushing the HDD/SSD into the slot.4.Reattach the HDD/SSD cover and fix it to the front panel with the 2screws.Installing a CFast CardThe MPC-2150 has a CFast slot that can be used to install a standard CFast card using a push-push mechanism. A list of compatible CFast cards can be found on Moxa’s website.1. Loosen the screws connecting the HDD/SSD cover to the MPC-2150.2. Insert the CFast card into the slot using the push-push mechanism.3. Reattach the CFast cover. Real Time ClockThe real time clock (RTC) is powered by a lithium battery. We strongly recommend that you do not replace the lithium battery without help from a qualified Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team at/rma/about_rma.aspx .Powering on/off the MPC-2150To power on the panel computer you may either connect power by connecting the Terminal Block to Power Jack Converter to theterminal block and then connect a power adapter, or you may connect the computer to an AC power source using the power cord. After the power source is connected, touch the Menu button to turn the computer on. It takes about 10 to 30 seconds for the system to boot up.To power off the MPC-2150 Series, touch the MENUbutton for 4 seconds; depending on your OS’s power management settings you may enter standby , hibernation , or system shutdown mode. If you encounter technical problems, touch and hold the MENU button for 10 seconds to force a hard shutdown of the system. Grounding the MPC-2150 SeriesProper grounding and wire routing help to limit the effects of noise from electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting the power source.。

公共法律服务机器人柜式机配置表

公共法律服务机器人柜式机配置表
约、规范性文件等。
(3)
提供法律援助机构、人民调解委员会、法律服务所、司法所、公证处、司法鉴定机构信息查询服务。支持按地区、按名称检索查询。
(4)
提供真实案例查询服务。
要求支持邻里纠纷、医患纠纷、交通事故纠纷、劳动纠纷、借贷纠纷、继承纠纷、婚姻家事、房屋买卖、收养问题、赡养问题、房屋租赁、物业纠纷、债权债务、消费维权、合同纠纷、票据纠纷、侵权纠纷、刑事犯罪、土地纠纷、旅游纠纷、工伤赔偿、林地纠纷、知识产权、征地拆迁、建设工程、行政、军人相关、合伙问题、公司问题等29类法律纠纷案例查询。
(4)
提供问答法律咨询服务,支持一问一答,输入想要咨询的法律问题,可立即获得解答。
要求支持交通事故、婚姻问题、消费维权、劳动纠纷、借贷纠纷、遗产继承、物业纠纷、企业用工(HR)、疫情问答、法律援助等咨询类别。
(5)
提供留言咨询服务,填写想要咨询的内容,律师会对咨询内容进行回复,可查询律师的回复内容。
产品型号:AFT-1IS-03T
产品材质:PC+ABS料
使用环境:可应用于化工电话机,防爆电话机,煤矿电话机,抗噪电话机,船舶电话机,监狱电话机,公共IC,投币电话机,防水防潮防尘电话机,自助终端以及其它各种通讯设备。
麦克风
免驱动USB麦克风
电源辅材
电源插座线材触摸笔1.ED状态灯灯控板亚力板板控制板丝印
信噪比:39db
动态范围:Upto69db
灵敏度:2.0V∕IUX-SeC@55Onm
接口类型:USB2.0HighSpeed
支持免驱协议:USBVideoC1.ass(UVC)
可调节参数:亮度对比度色饱和度色调清晰度伽玛增益白平衡逆光对比曝光度
彩色+红外:650um+850um

东芝 TS608电话 说明书

东芝 TS608电话 说明书
裝入或更換電池 .................................................................................. 10 將電池充電 .......................................................................................... 12 充電指示器 .......................................................................................... 13 SIM 卡 .................................................................................................... 13 插入 / 取出 SIM 卡 .............................................................................. 14 個人識別碼 (PINs) .................................................................................. 16 存儲卡插槽 ............................................................................................. 16 一般資訊 ................................................................................................. 18 零件和功能 ............................................................................................. 18 按鍵 .................................................................................................... 19 四方向導覽鍵 ...................................................................................... 20 快速鍵 ................................................................................................. 20 左 / 右邊屏幕按鍵 ................................................................................ 21 主目錄 ................................................................................................. 22

9070T150D1产品数据表说明书

9070T150D1产品数据表说明书

9070T150D1Industrial Control TransformersProduct Description PRODUCT DESCRIPTIONControl power transformers from Schneider Electric set the industry standard for design innovation and performance. They are designed with low impedance windings for excellent voltage regulation, and can accomodate the high inrush current associated with contactors, starters, solenoids, and relays.A variety of designs are available to meet the diverse needs of panel builders and machinery OEMs. The versatility of our control transformer line offers unparalleled options for design engineers. We also have one of the most extensive offering of custom products with no minimum order requirements.We have a national network of distributors to ensure prompt delivery, including industry leading delivery on custom products. In most cases, we can design, manufacture, and ship a custom unit in two weeks or less.The Global Product Offering—Type TType T is our most popular and complete line of control transformers. It comes with unmatched design innovations for top performance and is manufactured using the most advanced insulating materials. The Type T control transformer is the best choice if size and cost are of concern.The Exceptional Regulation Offering —Type EOConstructed with traditional materials and manufacturing processes, Type EO transformers are UL and CSA Component Recognized. Units are designed for 55°C rise. All units are 60HZ rated, withde-rated VA levels for 50HZ.Transformers with Fuse Block Protection—Types TF and EOFWe offer both product lines with factory installed overcurrent protection fuse blocks.Type TF and EOF transformers consist of two primary fuse blocks and one secondary fuse block, a configuration that meets the majority of overcurrent needs by panel builders and machinery OEMs. Since the fuse blocks are pre-wired and mounted on top of the transformer, the Type TF and EOF transformers have the same footprint as the Type T and Type EO units, respectively. This design frees up space normally used for separate fuse blocksWe also have an extensive fuse block offering for custom applications. See the overcurrent section of this catalog for full details.Leaded Control Transformer LineSchneider Electric offers transformers with internally pre-wired 24-inch primary and secondary leads, instead of terminal boards, to make installation easier and faster for many applications. These are only available for single voltage primary and single voltage secondary applications.MultiTapSchneider Electric offers Type T and Type EO transformers in the MultiTap version. The MultiTap control transformer was designed to respond to the increased need for voltage and stock flexibility. It combines multiple primary voltages with one or more secondary voltages, all in a single transfomer. The most flexible MultiTap voltage is the Universal, available on the Type T product line only. It allows for standard primary voltages of 208 to 600V and 110, 115, or 120V secondary voltages.Industrial Control TransformersType T TransformersTYPE T TRANSFORMERSThe Type T units are designed for the global market and are the best choice when size and cost are of concern. This is our most popular and complete offering of industrial control transformers. The following features are included:•50/60 Hz rated•Customer installed accessories (Finger-Safe covers, fuse blocks, fuse clips)•Type T transformers are designed with various temperature classes:—25–150 VA with a 55° C temperature rise, 105° C insulation —200–350 VA with a 80° C temperature rise, 130° C insulation —500–5000 VA with a 115° C temperature rise, 180° C insulationSchneider Electric manufactures a wide variety of voltage combinations for control transformers. The voltage combinations are expressed as “Voltage Codes”, and are embedded within the catalog number of the transformer. Standard codes are listed. If the voltage combination you need is not listed, please call your Schneider Electric distributor for assistance.CE MarkingIndustrial control transformers (ICTs) entering the European Union (EU) after January 1, 1997 are required by EU standards to have CE marking or Declaration of Conformity to CE. EU documentation requires compliance with specification EN 61 558 of the Low Voltage Directive. Type T ICTs from Schneider Electric comply with this specification and are third party tested to T ÜV standards, which adhere to, and are accepted by, EU standards. A Declaration of Conformity for all Type T units is available upon request.Because of different overload criteria in the CE specification,Schneider Elecric dual rates these transformers for UL VA, cUL VA, CSA VA, NOM VA and CE VA ratings (see “Type T VA Ratings” table). Because they are widely used with control circuit panels, ICTs are also required to comply with EN 60 204 and EN 61 558 in these applications. The Type T transformer line complies with EN 60 204 when Fingersafe ® covers are installed.For more information regarding CE marking, please contact your local Schneider Electric field sales office.Type T VA RatingsUL, cUL, CSA and NOM VA RatingCEVA Rating252550507575100100150150200200250160300200350250500300750500100063015001000200015003000200050003000Type T ListingsListingFileVA RangeUL E61239, Guide XPTQ225–5000cUL E612391500–5000CSALR37055, Guide 184-N-9025–1000EN947923, EN 61 558/01.89 (TUV ref: 00941-RAG/sg E9371495E01)25–2009579078, EN 61 558/01.89 (TUV ref: 00941-RAG/sg E9471921E01)250–10009579078, EN 61 558/01.89 (TUV ref: 00941-RAG/sg E9471921.02E01)1500–3000Industrial Control TransformersType T Transformers120 Volt Control SecondaryVoltage and Connection OptionsVoltage CodeVoltagesConnectionsPrimary SecondaryPrimarySecondaryD1220 x 440230 x 460240 x 480110115120220/230/240 V:Connect to H1 and H4Jumper H1 with H3Jumper H2 with H4440/460/480 V:Connect to H1 and H4Jumper H2 with H3Connect to X1 and X2DimensionsVA CatalogNumberFigureAcc. KeyA BCEFSlotsULCEINmmINmmINmmINmmINmmINmm25259070T25D11I 3.0979 3.0076 2.5866 2.0051 2.50640.20 x 0.38 5 x 1050509070T50D11I 3.0979 3.0076 2.5866 2.0051 2.50640.20 x 0.38 5 x 1075759070T75D11I 3.3485 3.3886 2.8973 2.3861 2.81710.20 x 0.48 5 x 121001009070T100D11I 3.3485 3.3886 2.8973 2.3861 2.81710.20 x 0.48 5 x 121501509070T150D11I 3.5991 3.7595 3.2081 2.8873 3.13800.20 x 0.38 5 x 102002009070T200D11I 3.5991 3.7595 3.2081 2.8873 3.13800.20 x 0.38 5 x 102501609070T250D12I 5.30135 3.7595 3.2182 2.8873 3.13800.20 x 0.38 5 x 103002009070T300D12I 4.74120 4.50114 3.8498 2.5665 3.75950.20 x 0.38 5 x 103502509070T350D12I 5.11130 4.50114 3.8498 3.0076 3.75950.20 x 0.38 5 x 105003009070T500D12I 5.49139 4.50114 3.8498 3.5690 3.75950.20 x 0.38 5 x 107505009070T750D12I 5.61143 5.25133 4.51115 3.4387 4.381110.28 x 0.567 x 1410006309070T1000D12I 6.30160 5.25133 4.51115 4.31109 4.381110.28 x 0.567 x 14150010009070T1500D12I 5.921507.06179 6.17157 4.13105 5.811480.28 x 0.567 x 14200015009070T2000D12I 7.171827.06179 6.17157 4.56116 5.811480.28 x 0.567 x 14300020009070T3000D13I 7.241849.002298.75222 4.631187.631940.44 x 1.1311 x 29500030009070T5000D13I9.152329.002298.752226.561677.631940.44 x 1.1311 x 2914T R A N S F O R M E R SIndustrial ControlClass 9070 / Refer to Catalogs 9070CT9901, 7400CT9601Square D ® Type T and MultiTap™ TransformersType T transformers are designed with low impedance windings forexcellent voltage regulation and can accommodate the high inrush current associated with contactors, starters, solenoids, and relays. As the most popular and complete line of control transformers with unmatched design innovations for top performance, Type Ts are manufactured using the most advanced insulating materials and are the best choice if size and cost are of concern. It is available in the MultiTap version, designed to respond to the increased need for voltage and stock flexibility. It combines multiple primary voltages with one or more secondary voltages, all in a single transformer.VAVA Catalog No.$ PriceH W D W e i g h t (l b s )U L /C S A /N O MCEin (mm)in (mm)in (mm)Primary 240 x 480 Secondary 120; Primary 230 x 460 Secondary 115; or Primary 220 x 440Secondary 11025259070T25D174.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.550509070T50D177.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D192.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D1103.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D1110.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D1136.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D1159.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D1176.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D1187.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D1233.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D1322.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D1390.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D1558.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D1678.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D1941.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D11582.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 208 Secondary 12050509070T50D390.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D3108.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D3121.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D3153.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D3195.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D3242.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D3248.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D3288.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D3314.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D3443.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D3558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D3780.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D3905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D31276.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D32010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 600 Secondary 120; Primary 575 Secondary 115; or Primary 550 Secondary 11050509070T50D590.00 2.58 (65.5) 3 (76.2) 3.09 (78.5) 2.575759070T75D5108.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D5121.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D5153.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D5195.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D5242.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D5248.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D5288.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D5314.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D5443.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D5558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D5780.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D5905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D51276.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D52010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 120 Secondary 120; Primary 115 Secondary 115; or Primary 110 Secondary 11050509070T50D24312.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D24324.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D24326.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D24348.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D24475.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D24477.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D24481.00 3.8 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D24483.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D24498.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D24560.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D24594.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D24717.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D24929.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D241463.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D242010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 277 Secondary 120Primary 277 Secondary 120 (continued)2002009070T200D4195.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D4242.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D4248.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D4288.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D4314.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D4443.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D4558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D4780.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D4905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D41276.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D42010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0VA VA Catalog No.$ PriceHW D W e i g h t (l b s )U L /C S A /N O MCEin (mm)in (mmin (mm)Primary 240 x 480 Secondary 120/240; Primary 230 x 460 Secondary 115/230; orPrimary 220 x 440 Secondary 110/22050509070T50D31125.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D31131.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D31138.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D31182.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D31235.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D31248.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D31290.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D31303.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D31339.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D31473.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D31558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D31816.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D31905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D311486.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D312010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 120 x240 Secondary 120/240; Primary 115 x 230 Secondary 115/230; orPrimary 110 x 2200 Secondary 110/22050509070T50D55312.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D55324.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D55326.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D55348.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D55475.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D55477.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D55481.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D55483.00 3.80 (96.5) 4.50(114.3) 5.09 (129.3)10.55003009070T500D55498.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D55560.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D55594.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D55856.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D55929.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D551588.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D552010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 240 X 480 Secondary 24/120 (24 V limited to 20% Capacity)50509070T50D1590.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D15108.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D15138.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D15153.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D15195.00 3.2 0(81.3) 3.75 (95.3) 3.59 (91.2) 5.52501609070T250D15248.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D15290.00 3.80 (96.5) 4.50 9114.3) 4.70 (119.4)8.53502509070T350D15303.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D15339.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D15473.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D15558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D15816.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D15905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0300020009070T3000D151486.008.46 (214.9)9.00 (228.6) 6.86 (174.2)60.0500030009070T5000D152010.008.46 (214.9)9.00 (228.6)8.73 (221.7)89.0Primary 480 Secondary 24050509070T50D1290.00 2.58 (65.5) 3.00 (76.2) 3.09 (78.5) 2.575759070T75D12324.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81001009070T100D12121.00 2.89 (73.4) 3.38 (85.8) 3.34 (84.8) 3.81501509070T150D12153.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.2) 5.52002009070T200D12195.00 3.20 (81.3) 3.75 (95.3) 3.59 (91.20) 5.52501609070T250D12242.00 3.25 (82.6) 3.75 (95.3) 5.25 (133.4)7.130********T300D12248.00 3.80 (96.5) 4.50 (114.3) 4.70 (119.4)8.53502509070T350D12288.00 3.80 (96.5) 4.50 (114.3) 5.09 (129.3)10.55003009070T500D12314.00 3.80 (96.5) 4.50 (114.3) 5.46 (138.7)11.97505009070T750D12443.00 4.43 (112.5) 5.25 (133.4) 5.66 (143.8)11.010*********T1000D12558.00 4.43 (112.5) 5.25 (133.4) 6.04 (153.4)20.6150010009070T1500D12780.00 6.16 (156.5)7.06 (179.3) 5.81 (147.6)34.0200015009070T2000D12905.00 6.16 (156.5)7.06 (179.3)7.04 (178.8)47.0VA VA Catalog No.$ PriceH W DW e i g h t (l b s )U L /C S A /N O MCEin (mm)in (mm)in (mm)9070T150D1。

弱电智能化采购内容及技术要求

弱电智能化采购内容及技术要求

弱电智能化采购内容及技术要求1.单声道输入通道:8路2.立体声输入通道:2组(4路单声道)3.单声道插入通道:8路4.单声道话筒接口幻像电源:+48V5.输出通道:一组立体声主输出、两路编组输出、两组辅助输出、一组立体声监听输出、一组CD/TAPE 输出、USB声卡播放输出、蓝牙播放输出6.频率响应:20Hz~20KHz ±0.5dB7.单声通道话筒到主输出最大增益:60dB±2dB8.单声通道线路到主输出最大增益:45dB±2dB9.立体声声通道线路到主输出最大增益:15dB±1dB10.通道串音:≤-90dB @ 20KHz11.左右声道串音:≤-90dB@ 20KHz12.信噪比(计权):≥95dB @ 1KHz 0dB13.主输出通道最大平衡输出:24dB±1.5dB14.主输出/编组最大非平衡输出:18dB±1.5dB15.辅助最大非平衡输出:18dB±1.5dB16.CD/TAPE输最大非平衡输出:18dB±1.5dB17.效果最大非平衡输出:18dB±1.5dB18.耳机输出:12dB/0.25W@32Ω;18dB@10KΩ;20Hz~20KHz19.通道间增益差:≤2dB20.失真度:≤0.002% @ 0dB 1KHz单声道通道均衡21.高频、可扫频中频、低频的频点范围:14KHz、200Hz~8KHz 、80Hz22.中心频点频偏与增益:频偏小于8%,最大增益为±15dB立体声通道均衡23.高频、中高频、中低频、低频的频点范围:20KHz、3KHz 、500Hz、20Hz24.中心频点频偏与增益:频偏小于8%,最大增益为±15dB25.效果器:21种DSP效果:HALL、ROOM、PLATE、AMBIENT、GATED、REVERS、VOICE、DEL&REV、ECHO40、ECHO50、DELAY、CHORUS、CHO&DEL、CHO&REV、FLANGER、FLA&DEL、FLA&REV、TREMOLO、TRE&REV、WAH WAH、WAH&REV26.通道削波指示灯:比削波电平提前3dB指示27.编组及主输出12段电平指示灯:+6dB,+3dB,0dB,-3dB,-6B,-9dB,-12dB,-15dB,-18d B,-24dB,-30dB,-36dB28.电源供应及功耗:~110-220V 50Hz , ≤60W。

1230 用户手册

1230 用户手册

BRAKE DRIVER TYPE
27 刹车驱动类型
ANTI-ROLLBACK TIME 28 防后滑时间
最小值 最大值 缺省值 单 位
-
-
ON
%
0
10
1
s
0
100
100
%
0
3
0
-
0
1000 400
ms
Emergency Reverse Parameters--------------------------------------
>200HZ 15V
17 低温限流 18 密封性
-25℃电枢电流限为 50%
IP53
10mA 10mA
19 重量 20 尺寸
1.1Kg 164×146×57mm
1)EMC EN50081-2/08.93 EN50082-2: 1995
2)安全性, 防飞车: EN1175
3)满足 UL583 绝缘性测试
0
50
0
%
5
100
100
%
0
3
0
-
MultiMode Parameters ---------------------------------------------
MODE SELECT TYPE 9 模式选择类型
备注:*2 COAST DECEL RATE 10 自由滑行减速率 值越大,减速时间越长
规 格 序号
名称
规格
24V 16KHZ
11 电磁刹驱动电流 2A 12 加速器控制信号 2/3 线,0-5KΩ/0-5V
>500AC
>7.5 为高
13 速度控制类型 14 工作环境温度

福泽CELSIUS H780移动工作站数据册说明书

福泽CELSIUS H780移动工作站数据册说明书

Data SheetFujitsu CELSIUS H780Mobility. Security. Virtual Reality.Meet the FUJITSU CELSIUS H780, the world’s first 39.6 cm (15.6-inch) mobile workstation combining ultimate security with future technologies. While creatives and innovators are working onincreasingly huge datasets, this machine will not weigh them down when showcasing designs in virtual reality at events or at the customer site.Need For SpeedWhen true workstation performance meets the elegant style of a laptopChoose between Intel® Core™ processors or powerful Intel® Xeon® processor E-2100M family supporting ECC memory Windows 10 Pro supportFull HD LED anti-glare displays (incl. touch option) Up to 64 GB DDR4 2400 MHz memory (ECC optional)Dual M.2 PCIe-SSD NVMe technology supports quick loading of core applicationsFull connectivity and worry-free docking experienceNo compromise in terms of connectivity, regardless of whether you are away, in a meeting or at your deskChoice of port replicators with mechanical or Thunderbolt™ 3 connectorMechanical port replicator: Offering charging capabilities for the mobile workstation.Thunderbolt™ 3 port replicator: 2x USB Type-C™ connector offering speed up to 40Gbps, and charging capabilities of to 15 W for e.g. mobile phone or power bank. The mobile workstation requires a power supply with at least 230 W.Full monitor connectivity support: 1x VGA and 1x HDMI.Mobility Meets SecurityData security and peace of mindOptional PalmSecure™, a leading-edge highly secure authentication system using biometric technology that authenticates users through vein pattern recognition Integrated SmartCard readerTPM 2.0 and Advanced Theft ProtectionWe are (VR) readyArchitects, engineers and designers can now showcase their work in a real-time, fully immersive VR environmentPowered by the NVIDIA® Quadro® P3200 VR-ready graphics card Ideal for mobile VR showcases at the customer site or at an eventEasy connectivity of the head-mount display to the HDMI portComponentsMemory modules8 GB (1 module(s) 8 GB) DDR4, 2,400 MT/s, PC4-2400, SO DIMM16 GB (2 module(s) 8 GB) DDR4, 2,400 MT/s, PC4-2400, SO DIMM32 GB (2 module(s) 16 GB) DDR4, 2,400 MT/s, PC4-2400, SO DIMMHard disk drives (internal)SSD SATA III, 512 GB, M.2 module, SEDSSD SATA III, 256 GB, M.2 module, SEDPCIe-SSD, NVMe, 512 GB Highend, M.2 module, SEDPCIe-SSD, NVMe, 512 GB Highend, M.2 modulePCIe-SSD, NVMe, 256 GB Highend, M.2 moduleHDD SATA III, 5,400 rpm, 1000 GBHDD SATA III, 5,400 rpm, 500 GBInterface add on cards/components(optional)3G/4G (optional)Sierra Wireless EM7455 (Cat. 6)Base unitPort Replicator interfaces (optional)Notes Thunderbolt Port Replicator Mechanical Port ReplicatorDC-in1x1xPower on switch---1Audio: line-in / microphone1x1xAudio: line-out / headphone1x1xUSB 2.0 total2x---USB 3.1 Gen1 (USB 3.0) total2x6x (4x USB Type-A, 2x USB Type-C) DisplayPort2x (1x through from TBT3 TypeC, 1x via internal DP-Splitter), resolution up to 3840 x 2160; no DP++ support2x, resolution up to 3840 x 2160, 16M colors, 60HzVGA1x (via TBT3 internal DP-splitter) resolution up to 1920 x1200, 16M colors, 60Hz1x resolution up to 1920 x 1200, 16M colors, 60HzDVI1x (via TBT3 internal DP-splitter) resolution up to 1920 x1200, 16M colors, 60Hz1x resolution up to 1920 x 1200, 16M colors, 60HzInterface Notes at least 230W power supply required for mobileworkstation DisplayPort next to USB and HDMI at Mobile WORKSTATION sharing the same channel (only one connection at a time possible); Dock DP2, CRT, DVI ports will share the same DP port bandwidth with VM3332ProductCompliance link https:///sites/certificatesWarrantyWarranty period 3 years (depending on country)Warranty type Bring-in Service / Collect & Return Service (depending on country) Product Support - the perfect extensionRecommended Service9x5, Onsite Response Time: Next Business DaySpare Parts availability at least 5 years after shipment, for details see https:///Recommended AccessoriesCELSIUS® H780 Port ReplicatorKitFlexibility, expandability, desktop replacement, investment protection – to name just a few benefits of Fujitsu’s docking options.Order Code: S26391-F2249-L300Privacy FiltersTo use privacy filters is a must in times of increased safety requirements. Fujitsu’s Privacy Filters block unauthorized views on your screen while you are sitting in an external meeting or working in a train. The front view remains clear for the user’s eyes only. The filters are easy to attach and what’s more: They also protect your screen from small scratches and damages.Order Code:S26391-F6098-L215Prestige Case 15 (2021)The Prestige Case 15 protects notebooks with up to 15.6-inch screens. The front compartment provides space for your power cord and office supplies.The large compartment is devided for your notebook and a tablet.Order Code:S26391-F1120-L60Prestige Trolley 17The Fujitsu Prestige Trolley 17 protects and transports notebooks withup to 17 inch screens, along with clothes and toiletries. It is the perfectcompanion in a city environment or for overnight stays with four spacious compartments. Smooth running wheels and a telescopic handle ensure convenience, while the central section protects your notebook with shock-absorbing foam.Order Code: S26391-F1194-L130Display P27-8 TS UHDThe FUJITSU Display P27-8 TS UHD is perfect for multi-monitor usescenarios with its 3840 x 2160 Ultra HD resolution and the thin bezelhousing. The monitor has a 78°/178° wide viewing angle and a 100% sRGB color space to deliver you a consistent high picture quality. Features like ECO function, the DisplayView™ IT Suite manageability software as a range of connectivity options meet the requirements of medium- and large-sized businesses.Order Code: S26361-K1610-V160ContactAddress: x-xx-x, street, city, state, ZIP code, country Phone: xx-xxxx-xxxx Fax : xx-xxxx-xxxxEmail:********************.com Website: /[country]2023-11-27 CE-ENdelivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such ownerMore informationAll rights reserved, including intellectual property rights. Changes to technical data reserved. Delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded.Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such owner.For further information see /terms_of_use.html Copyright © Fujitsu Technology Solutions。

【精品】网络交换路由防火墙等技术要求

【精品】网络交换路由防火墙等技术要求

四、计算机网络系统主要设备技术参数要求一、XX专网1.1、路由器*1、电源、主控等关键模块支持1:1冗余备份,所有单板支持热拔插,插槽数≥6个*2、包转发率≥12Mpps,交换容量≥40Gbps*3、内存≥4G,FLASH≥4G4、支持GESFP、GERJ45、GECombo、FE、155MPOS、155M通道化POS、E1/CE1等接口类型,支持Wlan、10GE接口*5、整机最大支持三层GE接口数≥84,整机最大支持POS/CPOS接口数≥166、支持RIP1/2、OSPF、IS-IS、BGP等路由协议,整机IPV4FIB表项≥512K7、支持RIPng、OSPFv3、IS-ISv6、BGP4+等IPv6协议,整机IPV6FIB表项≥128K8、支持IPv4/IPv6双协议栈,支持IPv4/v6过渡机制:手工通用隧道和自动6To4隧道、6PE、NAT-PT等9、完备的VPN功能,包括BGP/MPLSVPN、二层MPLSVPN(VPLS/VPWS)、L2TPVPN、IPsecVPN、GREVPN等。

10、支持丰富的队列技术、拥塞避免技术、调度技术,支持CAR,可以为用户提供完善的QOS保障措施11、支持防火墙功能,支持应用代理和应用过滤等技术,支持防DDOS攻击,减轻或解除网络攻击的威胁12、通过了CE认证,包括EMC测试等13、通过了IPV6READY金牌认证14、提供信息产业部的电信设备IPV4和IPV6进网许可证及入网检测报告*15、与交换机、防火墙、WLAN同一品牌,便于管理1.2、防火墙1、*网络接口≥10个,其中千兆接口≥2个,百兆接口≥8个2、*防火墙吞吐量≥1.5Gbps,并发会话数≥1M,每秒新建会话数≥20K/s,策略数≥4K3、支持接口DHCP和PPPoE接入,支持静态路由设置4、支持基于源地址策略路由功能。

支持IP/MAC地址绑定。

5、*支持RIPv1,RIPv2,OSPF,BGP,组播路由等动态路由设置6、*支持IPv6,支持IPv4与IPv6混合环境7、*支持本地数据库,LDAP,RADIUS,TACACS+,RSASecureID等认证方式8、*支持VoIP协议(SIP,SCCP)的NAT穿越9、*支持并提供防病毒模块,支持对HTTP、FTP、SMTP、POP3等协议的病毒检测和过滤10、*支持虚拟防火墙系统(虚拟域)的功能,并提供8个以上虚拟防火墙许可。

英威腾EC160电梯智能整体机调试说明

英威腾EC160电梯智能整体机调试说明
1.1 硬件配置表................................................................................................................................1 1.2 软件标准功能表........................................................................................................................2 1.3 软件选配功能表........................................................................................................................7
EC160电梯智能整体机用户手册
序言

序言
EC160 电梯智能整体机是集驱动技术、控制技术、网络通讯技术为一体设计理念的新一代智能 化电梯控制系统。它采用先进的变频矢量控制技术、智能化电梯控制技术、网络通讯技术,将电梯 的驱动、控制、管理有机地结合为一体,使产品在安全可靠性、操作简易性、经济性、个性化设计 等方面都有了全方位的优化提高。EC160 电梯智能整体机具有以下主要特点:
第二章 使用前安全须知与注意事项........................................................................................................9 2.1 与安全有关的标识说明.............................................................................................................9 2.2 读者对象....................................................................................................................................9 2.3 警告标记....................................................................................................................................9 2.4 安全注意事项..........................................................................................................................10 2.4.1 开箱检查...............................................................................................................................10 2.4.2 拆卸与安装...........................................................................................................................10 2.4.3 接线注意事项.......................................................................................................................10 2.4.4 运行注意事项....................................................................................................................... 11 2.4.5 维护与检查注意事项............................................................................................................ 11 2.4.6 其它注意事项.......................................................................................................................12

TAIDEN多媒体智能会议系统项目设计方案

TAIDEN多媒体智能会议系统项目设计方案

TAIDEN多媒体智能会议系统项目设计方案第一章方案设计1.1 TAIDEN智能会议系统概述随着网络信息时代的来临,每一场会议对其使用的设备要求也越来越高。

“实用、美观、完善”的会议设备成为人们青睐的器材。

数字会议系统以革命性的数字技术取代了传统的会议模式。

以其数字化的性能加上操作方便的软件控制,满足现代会议的一切管理需求。

TAIDEN数字会议系统功能包括:收听、发言、请求发言、接收屏幕显示资料、IC卡身份认证、按键签到、参加电子表决、视像跟踪、接收原发言语种的同声传译。

配置完善的管理软件,既可以简化会场设备,又可以随意扩充功能,是一套集多种功能于一体的会议设备,同时也节省了工程经费。

它是利用简单的系统处理和数字信号传送,无论是对小型会议还是数千人的多语种大型国际性会议都能管理得得心应手、轻松自如。

它不但具有多功能、高保真音质、数据保密、传输可靠等特点,还可以对整个会议过程进行全面的控制。

只要接入控制电脑,操作员在相应的软件模块的帮助下便可以自如地对会议过程进行实施监控,包括:基本的话筒管理、投票表决、IC卡签到、数据管理和资料显示以及多达64种语言的同声传译。

即使在没有接入控制电脑时,它仍然是一套完善的数字会议系统。

每一台单元具备有带开关的麦克风、内置扬声器、LCD显示屏、发言指示灯。

只需将单元一台一台串联起来配备相应的操作软件便可以组合成完整的会议系统。

它对所有会议控制的基本原则都一样,变化的只不过是系统的规模。

系统可以根据会议的需要,接入相应数量的单元,补充软件就可以增设更多功能,对系统规模的扩展非常简单。

台电公司推出的智能会议系统整合了发言、表决、同声传译、摄像机自动跟踪,会议签到,中央控制等诸多功能,实现了会议系统和中央控制系统的无缝连接,经国内知名专家组评定,一致认为:国内首创,国际先进。

1.2 系统工作环境1 温度范围:●运输温度: -400C – +700C●工作温度: 00C - +450C2 湿度范围⏹最大相对湿度:<95%3 安全标准: 符合EN600651.3 标准和规范1.4 数字会议系统设计指导思想和原则安全性:对于任何一场会议而言,保证每一位出席会议的代表的安全是首要的条件。

BNS 260 生活用电器安全设备手册说明书

BNS 260 生活用电器安全设备手册说明书

DataOrdering dataProduct type descriptionBNS 260-11/01ZG-R Article number (order number)101184376EAN (European Article Number)4030661321745eCl@ss number, Version 9.027-27-24-02CertificationsCertificates DGUVTÜVcULus EACGeneral dataProduct nameBNS 260StandardsIEC 60947-5-3 BG-GS-ET-14 Installation conditions(mechanical)quasi-flush Enclosure materialGlass-fibre, reinforced thermoplastic Gross weight 60 g General data - FeaturesCoding Yes BNS260-11/01ZG-RLong lifeSmall bodyPre-wired cableno mechanical wear26 mm x 36 mm x 13 mmInsensitive to soilingThermoplastic enclosure Concealed mounting possible Insensitive to transverse misalignmentIntegral System Diagnostics,YesstatusNumber of openers2Number of shutters1Number of safety contacts2Number of cable wires6Safety appraisalStandards ISO 13849-1Mission Time20 Year(s)Safety appraisal - Safety outputsB10d- Value Normally-closed25,000,000 Operationscontact/Normally open contact(NC/NO)Mechanical dataActuating element MagnetDoor hinge RightEnsured switch distance "ON" S5 mmaoEnsured switch distance "OFF" S15 mmarAxial misalignment, a horizontal and vertical misalignment of the safetysensor and the actuator are tolerated. The possible misalignment dependson the distance of the active surfaces of the sensor and the actuator. Thesensor remains active within the tolerance range.Direction of motion Head-on to the active surfaceMechanical data - Connection techniqueTerminal Connector CableLength of cable 1 mWire cross-section0.25 mm2Material of the Cable mantle PVCMechanical data - DimensionsHeight of sensor36 mmLength of sensor13 mmWidth of sensor26 mmAmbient conditionsProtection class IP67Ambient temperature, minimum-25 °CAmbient temperature, maximum+70 °CStorage and transporttemperature, minimum-25 °CStorage and transporttemperature, maximum+70 °CResistance to vibrations to EN60068-2-610 … 55 Hz, amplitude 1 mmRestistance to shock30 g / 11 msElectrical dataVoltage type DC (direct current)Switching voltage, maximum24 VDCSwitching current, maximum0.01 ASwitching capacity, maximum0.24 WSwitching frequency, maximum 5 HzStatus indicationNote (Integral SystemDiagnostics, status )The LED is illuminated when the guard is closed. Scope of deliveryIncluded in delivery Actuators must be ordered separately. AccessoryRecommendation (actuator)BPS 260SRB-E-301STSRB-E-201LCNotesNote (General)Contact symbols shown for the closed condition of the guard device. The contact configuration for versions with or without LED is identical.Circuit exampleNote (Wiring diagram)Contact S21-S22; S13-S14 must be integrated in the safety circuit. Ordering codeProduct type description:BNS 260-(1)(2)Z(3)-(4)-(5)(1)11 1 NO contacts/1 NC contact02 2 NC contact(2)without with diagnostic output/01 1 NC contact(3)without without LED switching conditions displayG with LED switching conditions display(4)without Pre-wired cableST with connector(5)L Door hinge on left-hand sideR Door hinge on right-hand sidePicturesProduct picture (catalogue individual photo)ID: kbns2f23| 314,7 kB | .jpg | 352.778 x 246.239 mm - 1000 x 698Pixel - 72 dpi| 25,0 kB | .png | 74.083 x 51.858 mm - 210 x 147Pixel - 72 dpi| 39,7 kB | .jpg | 27.093 x 18.881 mm - 320 x 223 Pixel- 300 dpiDimensional drawing basic componentID: kbns2g05| 131,1 kB | .jpg | 352.425 x 417.336 mm - 999 x 1183Pixel - 72 dpi| 4,5 kB | .png | 73.731 x 87.489 mm - 209 x 248 Pixel- 72 dpi| 34,5 kB | .jpg | 112.536 x 133.35 mm - 319 x 378Pixel - 72 dpi| 37,3 kB | .cdr |DiagramID: kbns2k04| 25,1 kB | .jpg | 112.889 x 27.164 mm - 320 x 77 Pixel- 72 dpi| 19,5 kB | .cdr |Characteristic curveID: kbns2d03| 36,8 kB | .cdr || 40,4 kB | .jpg | 112.889 x 74.789 mm - 320 x 212Pixel - 72 dpi| 18,5 kB | .png | 74.083 x 49.036 mm - 210 x 139Pixel - 72 dpiCharacteristic curveID: kbns2d02| 19,2 kB | .png | 74.083 x 49.389 mm - 210 x 140Pixel - 72 dpi| 40,8 kB | .jpg | 112.889 x 75.142 mm - 320 x 213Pixel - 72 dpi| 36,3 kB | .cdr |Clipart| 20,1 kB | .cdr || 1,7 kB | .png | 74.083 x 52.564 mm - 210 x 149 Pixel- 72 dpiK.A. Schmersal GmbH & Co. KG, Möddinghofe 3, D-42279 WuppertalThe details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.Generated on 08.07.2020 19:14:08。

使用产品前请仔细阅读本使用说明书

使用产品前请仔细阅读本使用说明书

说明:若在配置 RAID 之前, “RAID Disk ”已经显示为“No” ,且变为灰色不可用 状态,此时有以下一种可能原因。 1) 磁盘容量小于阵列所需最小容量。 2) 磁盘容量小于主磁盘已存在的数据大小。 3) 磁盘已经被选中作为阵列热备磁盘。
- 7 -
4) 磁盘已经被其他阵列所占用。 7.当出现下图所示画面,按下<M>则代表保留第一块磁盘已有的数据,并且可以将 第一块磁盘已有的数据拷贝到第二块新添加的磁盘。 按下<D>代表清楚阵列里所有逻辑磁盘的数据。
方正科技服务器板卡使用手册
概述
本手册主要包括安装 1068E SAS 扩展卡在服务器上的简要规格、 硬件装配方法、 创建 RAID 说明以及主流操作系统的驱动加载方法。
- 1 -
1 规格说明
1.1 简要规格
控制器 通道数 支持设备类型 速率 支持 RAID 类型 操作系统支持 LSI SAS 1068E 8 SAS/SATAII SATAII/SAS 3Gb/s RAID0/1/10/1E Windows® Server 2003/2000/XP/Vista Red hat® Enterprise Server 8/9/10 SUSE Linux Enterprise 16.4cm × 4cm(1U 高度)
同 RAID1 为磁盘镜像技术, 区别在于可支持 3 块或 3 块以上的磁盘镜像。 利用率同 样为 50%。
3.2 LSI RAID 配置管理说明
注意: 1. 在配置 RAID1 和 1E 时,建议使用容量相同的磁盘,否则,最终阵列的大 小会以阵列中最小容量的逻辑磁盘为准。 2. 不建议在同一个阵列中混用 SAS 和 SATA 磁盘。 说明:本章节所有图片均为参考示例,其中所涉及的版本、日期等相关信息请 以具体实物为准。

罗弗公司2010年版低功耗高电压负压电子传输器2SB1182和2SB1240产品说明书

罗弗公司2010年版低功耗高电压负压电子传输器2SB1182和2SB1240产品说明书

Medium power transistor (-32V, -2A)2SB1182 / 2SB1240●Features1) Low V CE(sat).V CE(sat) = -0.5V (Typ.) (I C /I B = -2A / -0.2A)2) Complements 2SD1758 / 2SD1862.●StructureEpitaxial planar type PNP silicon transistor●Absolute maximum ratings (Ta=25︒C)∗1 Single pulse, Pw =100ms∗2 Printed circuit board, 1.7mm thick, collector copper plating 100mm 2or larger.ParameterV CBO V CEO V EBO P C Tj Tstg−40V V V A(DC)W (Tc =25°C )W°C °C−32−5−2I CA (Pulse)−3101∗1∗22SB11822SB1240150−55 to 150Symbol Limits Unit Collector-base voltage Collector-emitter voltage Emitter-base voltage Collector currentCollector power dissipationJunction temperature Storage temperature●Electrical characteristics (Ta=25︒C)∗ Measured using pulse current.ParameterSymbol BV CBO BV CEO BV EBO I CBO I EBO h FE V CE(sat)f T CobMin.−40−32−5−−120−−−−−−−−10050−−−−1−1390−0.8∗∗−−V I C = −50μA I C = −1mA I E = −50μA V CB = −20V V EB = −4V I C /I B = −2A/ −0.2A V CE = −5V, I E =0.5A, f =100MHz V CB = −10V, I E =0A, f =1MHzV VμA μA −−V CE = −3V, I C = −0.5AV MHz pFTyp.Max.Unit Conditions−0.5Collector-base breakdown voltage Collector-emitter breakdown voltage Emitter-base breakdown voltage Collector cutoff current Emitter cutoff currentCollector-emitter saturation voltage DC current transfer ratio Transition frequency Output capacitance●Packaging specifications and h FEPackage CodeBasic ordering unit (pieces)TapingTL 2500h FE QR 2SB1182−TV22500−QR2SB1240Typeh FE values are classified as follows :Item h FEQ 120 to 270R 180 to 390●Electrical characteristic curvesFig.1 Grounded emitter propagationcharacteristicsBASE TO EMITTER VOLTAGE : V BE (V)C O L L E C T O R C U R R E N T : I C (m A )−−−−−−−−−−Fig.2 Grounded emitter outputcharacteristics−−−−−C O L LE C T O R C U R R E N T : I C (A )COLLECTOR TO EMITTER VOLTAGE : V CE (V)Fig.3 DC current gain vs.collector curren ( )D C C U R RE N T G A I N : hF ECOLLECTOR CURRENT : I C (mA)Fig.4 DC current gain vs.collector current ( )D C C U R RE N T G A I N : hF ECOLLECTOR CURRENT : I C (mA)Fig.5 Collector-emitter saturationvoltage vs. collector current ( )C O L L E C T O R S A T U R A T I O N V O L T A G E : V C E (s a t ) (m V )−−−−Fig.6 Collector-emitter saturationvoltage vs. collector current ( )−−−−−C O L L E C T O R S A T U R A T I O N V O L T A G E : V C E (s a t ) (m V )COLLECTOR CURRENT : I C (mA)Fig.7 Base-emitter saturation voltagevs. collector currentCOLLETOR CURRENT : I C (mA)B A S E S A T U R A T I O N V O L T A G E : V B E (s a t )(V )−−−−−Fig.8 Gain bandwidth product vs.emitter currentEMITTER CURRENT : I E (mA)T R A N S I T I O N F R E Q U E N C Y : f T (M H z )Fig.9 Collector output capacitance vs.collector-base voltageEmitter input capacitance vs. emitter-base voltageCOLLECTOR TO BASE VOLTAGE : V CB (V)EMITTER TO BASE VOLTAGE : V EB (V)C O L L E C T O R O U T P U T C A P AC I T A N C E : C o b (p F )E M I T T E R I N P U T C A P A C I T A N C E : C i b (p F )Fig.10 Safe operation area(2SB1182)−−−−−−−−−−C O L L E C T O R C U R R E N T : I C (A )COLLECTOR TO EMITTER VOLTAGE : V CE (V)NoticeN o t e sNo copying or reprod uction of this d ocument, in part or in whole, is permitted without theconsent of ROHM Co.,Ltd.The content specified herein is subject to change for improvement without notice.The content specified herein is for the purpose of introd ucing ROHM's prod ucts (hereinafter"Products"). If you wish to use any such Product, please be sure to refer to the specifications,which can be obtained from ROHM upon request.Examples of application circuits, circuit constants and any other information contained hereinillustrate the standard usage and operations of the Products. The peripheral conditions mustbe taken into account when designing circuits for mass production.Great care was taken in ensuring the accuracy of the information specified in this document.However, should you incur any d amage arising from any inaccuracy or misprint of suchinformation, ROHM shall bear no responsibility for such damage.The technical information specified herein is intended only to show the typical functions of andexamples of application circuits for the Prod ucts. ROHM d oes not grant you, explicitly orimplicitly, any license to use or exercise intellectual property or other rights held by ROHM andother parties. ROHM shall bear no responsibility whatsoever for any dispute arising from theuse of such technical information.The Products specified in this document are intended to be used with general-use electronicequipment or devices (such as audio visual equipment, office-automation equipment, commu-nication devices, electronic appliances and amusement devices).The Products specified in this document are not designed to be radiation tolerant.While ROHM always makes efforts to enhance the quality and reliability of its Prod ucts, aProduct may fail or malfunction for a variety of reasons.Please be sure to implement in your equipment using the Products safety measures to guardagainst the possibility of physical injury, fire or any other damage caused in the event of thefailure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHMshall bear no responsibility whatsoever for your use of any Product outside of the prescribedscope or not in accordance with the instruction manual.The Prod ucts are not d esigned or manufactured to be used with any equipment, d evice orsystem which requires an extremely high level of reliability the failure or malfunction of whichmay result in a direct threat to human life or create a risk of human injury (such as a medicalinstrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of anyof the Prod ucts for the above special purposes. If a Prod uct is intend ed to be used for anysuch special purpose, please contact a ROHM sales representative before purchasing.If you intend to export or ship overseas any Product or technology specified herein that maybe controlled under the Foreign Exchange and the Foreign Trade Law, you will be required toobtain a license or permit under the Law.Thank you for your accessing to ROHM product informations.More detail product informations and catalogs are available, please contact us.ROHM Customer Support System/contact/。

DS-K1T805系列访问控制终端快速启动指南说明书

DS-K1T805系列访问控制终端快速启动指南说明书

DS-K1T805SeriesAccess Control TerminalQuick Start GuideUD32453B©2023Hangzhou Hikvision Digital Technology Co.,Ltd.All rights reserved.About this ManualThe Manual includes instruc�ons for using and managing the Product.Pictures,charts,images and all other informa�on hereina�er are for descrip�on and explana�on only.The informa�on contained in the Manual is subject to change, without no�ce,due to firmware updates or other reasons.Please find the latest version of this Manual at the Hikvision website(h�ps:///).Please use this Manual with the guidance and assistance of professionals trained in suppor�ng the Product. Trademarksand other Hikvision’s trademarks and logos are the proper�es of Hikvision in various jurisdic�ons.Other trademarks and logos men�oned are the proper�es of their respec�ve owners.DisclaimerTO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,THIS MANUAL AND THE PRODUCT DESCRIBED,WITH ITS HARDWARE,SOFTWARE AND FIRMWARE,ARE PROVIDED“AS IS”AND“WITH ALL FAULTS AND ERRORS”.HIKVISION MAKES NO WARRANTIES,EXPRESS OR IMPLIED,INCLUDING WITHOUT LIMITATION,MERCHANTABILITY,SATISFACTORY QUALITY,OR FITNESS FOR A PARTICULAR PURPOSE.THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK.IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL,CONSEQUENTIAL,INCIDENTAL,OR INDIRECT DAMAGES, INCLUDING,AMONG OTHERS,DAMAGES FOR LOSS OF BUSINESS PROFITS,BUSINESS INTERRUPTION,OR LOSS OF DATA, CORRUPTION OF SYSTEMS,OR LOSS OF DOCUMENTATION,WHETHER BASED ON BREACH OF CONTRACT,TORT (INCLUDING NEGLIGENCE),PRODUCT LIABILITY,OR OTHERWISE,IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS,AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK,HACKER ATTACK,VIRUS INFECTION,OR OTHER INTERNET SECURITY RISKS; HOWEVER,HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS,AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.ESPECIALLY,YOU ARE RESPONSIBLE,FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES,INCLUDING WITHOUT LIMITATION,RIGHTS OF PUBLICITY,INTELLECTUAL PROPERTY RIGHTS,OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES,INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION,THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS,ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE,OR IN SUPPORT OF HUMAN RIGHTS ABUSES.IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW,THE LATTER PREVAILS.Data Protec�onDuring the use of device,personal data will be collected,stored and processed.To protect data,the development of Hikvision devices incorporates privacy by design principles.For example,for device with facial recogni�on features, biometrics data is stored in your device with encryp�on method;for fingerprint device,only fingerprint template will be saved,which is impossible to reconstruct a fingerprint image.As data controller,you are advised to collect,store,process and transfer data in accordance with the applicable data protec�on laws and regula�ons,including without limita�on,conduc�ng security controls to safeguard personal data, such as,implemen�ng reasonable administra�ve and physical security controls,conduct periodic reviews and assessments of the effec�veness of your security controls.Align andsupplied2006/66/EC This with standards 2014/30/EU,WarningIn the use of regulationsdirect The If enter The If Make Create Click Click If you should Click 1.Connect Make sure 2.Open address 3.Enter Make sure 2.Enter 3.Click Authentication Card:Present authentication LoginWhen ground。

SMT设备参数简介

SMT设备参数简介

FUJI NXTⅡ
环境要求 1.电压:110VAC(+-10%), 2.频率:50/60 Hz 3.气压要求:0.5Mpa (5kgf/cm2) 4.温度:15℃--35℃ 5.湿度:30%----80% 技术参数
1.贴片范围:01005-7.5*7.5mm,高度9.5mm以下的零件 2.生产能力:V12:26000cph;H08:10500cph ;H04:6500cph 3.贴片精度:±0.038mm 4.适用基板:最大534x610mm,最小48x48mm, 厚度0.3-4mm 5.料架支持:160个站位 6.机器尺寸:L2590mm,W1900mm,H1474mm(排除信号塔) 7.机器重量:4t
真空烘箱
技术参数 1.真空度范围:0~0.1MPa 2.漏气量:1KPa/小时 3.机器尺寸:L940mm,W830mm, H1250mm 4.工作尺寸:L620mm,W650mm,H610mm 5.机器重量:0.4t 环境要求 1.电压:220VAC(+-10%) 2.频率:50/60 Hz 3.气压要求:0.5Mpa (5kgf/cm2) 4.温度:0℃--40℃ 5.湿度:30%----80%
和西(WS-450PC-N)
环境要求 1.电压:380VAC(+-10%) 2.频率:50/60 Hz 3.温度:15℃--35℃ 4.湿度:30%----80% 技术参数 1.预热区数量:4 2.预热区长度:1900mm 3.PCB运送方式:链传动 4.适用基板:50mm~450mm 5.传送速度: 0-1800m/min 6.机器尺寸:L4350mm,W1300mm,H1650mm 7.机器重量:1.95t
FUJI XPF_L
环境要求 1.电压:

DS-K1T502DBFWX-C 终端板配置指南说明书

DS-K1T502DBFWX-C 终端板配置指南说明书

Contrôle d’accès DS-K1T502DBFWX-CGuide de configurationTable des matièresContenu (1)Comment alimenter la platine de terminal ? (2)Comment câbler la platine de terminal avec une gâche électrique ? (3)Comment configurer la platine de terminal avec un PC portable ? (5)Activation de la platine de terminal sur SADP (5)Modification de l’adresse IP du PC (6)Comment accéder à la page web ? (7)Comment configurer le code d’entrée ? (8)Comment ajouter un utilisateur ? (9)Ajouter un pin code (9)Ajouter une carte (9)Ajouter une empreinte (10)Comment appeler le moniteur intérieur via la platine de terminal ? (13)Comment configurer un événement de DoorBell ? (14)ContenuPlatine de terminale DS-K1T502 Câble adapteur RJ45Adaptateur de groupe de câble intégration Adaptateur de groupe de câble d’alarmeComment alimenter la platine de terminal ?Reliez l’adaptateur de groupe de câble intégration à une source d’alimentation de 12V (qui n’est pas fourni dans le kit).En utilisant le câble adaptateur RJ45, câblez la platine de terminal avec le commutateur(switch). Lorsque la platine de terminal présente deux voyants rouges, cela signifie qu'elle est bien alimentée.Comment câbler la platine de terminal avec une gâche électrique ?L’adaptateur de groupe de câble intégration contient ces bornes : une entrée d'alimentation, une entrée d'alarme, une sortie d'alarme, une sortie RS-485, une sortie Wiegand et un verrouillage de porte. Le schéma de l’adaptateur de groupe de câble intégration est le suivant :Pour câbler la gâche électrique avec la platine de terminal, nous nous intéressons au Groupe D, celui qui est marqué LOCK sur l’étiquette.Si votre gâche électrique est du type NC (normalement fermé), ne dépasse pas 30V et 1A.Ou alors vous avez une ventouse électromagnétique (qui compose elle-même un contact de porte) :Si votre gâche électrique est du type NO (normalement ouvert), ne dépasse pas 30V et 1A.Comment configurer la platine de terminal avec un PC portable ?Activation de la platine de terminal sur SADPTélécharger sur votre PC, l’application SADP depuis un navigateur, voici le lien :https:///fr/support/tools/hitools/clea8b3e4ea7da90a9/Sur un switch, câbler la platine de terminal et votre PC portable avec des câbles RJ45.Par la suite, depuis SADP, vous trouverez votre terminal comme l’image ci-dessous. Cochez la case à gauche et donner un mot de passe d’activation de l’appareil, mémoriser le.Modification de l’adresse IP du PCAssurez-vous que l'adresse IP de votre PC est sur la même passerelle que celle du terminal pour pouvoir configurer les paramètres et maintenir le fonctionnement de l’appareil.L’adresse IP donner par défaut pour le terminal est de 192.0.0.64.Par exemple, le Gateway (Passerelle) du terminal est de 192.0.0.1, donc le segment du réseau est de 192.0.0. Pour accéder à la configuration, l’adresse IP de votre PC doit être sous la forme 192.0.0.XX. Attention le .XX ne peut pas être un chiffre déjà pris par un autre équipement de ce réseau local, comme le .64, qui est déjà pris par la platine de terminal.Nous décidons ici de modifier l’adresse IP du PC sous la forme 192.0.0.50. Pour modifier l’adresse IP et la passerelle de votre PC, voici les étapes à suivre :Comment accéder à la page web ?Lorsque vous avez l’appareil qui est détecté puis activé sur SADP et que votre ordinateur est dans le même réseau local que l’appareil, double cliquez sur l’adresse IP ou entrer l’adresse IP dans la barre de recherche d’un navigateur (de préférence Internet Explorer), par la suite, vous pouvez accéder sur la page web de cet appareil.Choisissez la langue da la page web et pour pourvoir configurer, mettez « admin » comme nom d’utilisateur et rentrer le code d’activation de votre appareil.Comment configurer le code d’entrée ?Sur la page de configuration, accéder la rubrique Contrôl e d’accès pour créer les mots de passe nécessaires.Ces trois mots de passe sont utilisés dans différentes situations :- "Code de contrainte" est un code qui déclenchera automatiquement un événement à notifier via la platine de terminale une fois que vous l'aurez saisi.- "Super mot de passe" est utilisé comme un mot de passe administrateur, et considérer les règles d’identifiant inexistant (par exemple règle anti-passback).- "Unlock password" est le mot de passe normal pour ouvrir votre porte.Une fois que vous avez correctement configuré et enregistré les MDP, pour ouvrir votre porte, taper : les MDP que vous avez configurés + #.Par exemple, si vous avez mis 1234 comme Unlock password pour ouvrir la porte, il faut tapez : 1234#. Idem pour les deux autres MDPComment ajouter un utilisateur ?Ajouter un pin codeAccéder à la page d’utilisateur, cliquez sur « Ajouter », remplissez les informations correspondantes et saisissez dans Mot de passe pour créer le pin code associé à cette personne.Ajouter une carteVous pouvez également ajouter une carte pour cette personne en cliquant sur Ajouter une carte.En cliquant sur le bouton de lecture, placez la carte correspondante devant la zone de l ecture et une fois que le numéro de la carte est affiché, l’enregistrement de la carte est acquis.Cliquez « OK » pour finaliser l’enregistrement.Ajouter une empreinteSi vous souhaitez utiliser l’empreinte digitale pur ouvrir la porte, cliquez sur « Ajouter une empreinte digitale ». Posez votre doigt sur le lecteur d’empreinte et l’assistante vocale vous guidera à enregistrer votre e mpreinte.D’après l’assistante vocale, vous devrez mettre 3 fois votre doigt sur le lecteur d’empreinte pour que l’appareil enregistre correctement votre empreinte.Cliquez « OK » pour enregistrer cet utilisateur avec le pin code, la carte et l’empreinte associé.Vous pouvez ainsi visualiser l’utilisateur enregistré depuis cette page.Pour une autre façon d’enregistrer un utilisateur, consultez le guide « Comment ajouter des cartes à la station extérieure ? » dans le lien suivant :https:///drive/folders/1l0TlgGy2jhOtpABpsQKgtutYIuSlCAd5Comment appeler le moniteur intérieur via la platine de terminal ?Sur un switch, câbler la platine de terminal et le moniteur intérieur avec des câbles RJ45. Assurer que vos équipements sont dans le même segment du réseau local.Cliquez sur Paramètres →Paramètres avancés (à droite et dernière icône) →Configuration →Gestion appareils (3ème icône) →Station porte principale (série D).Sélectionner la platine de terminal DS-K1T502DBFWX-C.Votre terminal peut ainsi appeler votre moniteur intérieur en tapant sur le clavier : numéro de chambre associé au moniteur intérieur + bouton d’appel.Par exemple, si votre moniteur se situe dans la chambre 1, il faut taper : 1 + bouton d’appel.Comment configurer un événement de DoorBell ?Si vous souhaitez configurer un évènement à notifier, accéder à la rubrique « Événement de base » pour ajouter un évènement relatif, comme l’image indiqué ci-dessous. Ensuite, réalisez le câblage entre l’adap ta teur de groupe de câble d’alarme (cf. page 1) et l’appareil désiré dans le but d’utiliser ce signal d’impulsion.。

Artisan Technology Group设备维修与售卖手册说明书

Artisan Technology Group设备维修与售卖手册说明书

Serie PSS SB 3006-3Units with two SafetyBUS p InterfacesAll rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes.Suggestions and comments for improving this documentation will be gratefully received.The names of products, goods and technologies used in this documentation are registered trademarks of the respective companies. Automation Workbench®, Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSS®, SafetyBUS p® are registered trademarks of Pilz GmbH & Co. KG.ContentsContentsIntroductionThis operating manual explains the function and operation of theprogrammable safety system, describes the installation and providesguidelines on how to connect the inputs and test pulse outputs onprogrammable safety systems from the PSS SB 3006-3 series. A PSSfrom the PSS SB 3006-3 series is a 3rd generation programmable safetysystem.For connection to SafetyBUS p, units are available with one SafetyBUS pinterface as well as two SafetyBUS p interfaces.This operating manual describes the programmable safety systems fromthe PSS SB 3006-3 series with two SafetyBUS p interfaces.Different interfaces are available for connection to various non-safety-related standard bus systems, depending on the unit type. Theseinterfaces are described in separate operating manuals. The necessaryoperating manuals are supplied with the relevant unit types.Please refer to the PSS-range manuals, in particular the information andrequirements stated in the “PSS-Range Safety Manual”, “FS SystemDescription”, “ST System Description” and also the “SafetyBUS pInstallation Manual” from the SafetyBUS p manual package.Y ou will need to be conversant with the information in these manuals inorder to fully understand this manual.This documentation is intended for instruction and should be retained forfuture reference.IntroductionValidity of documentationThis documentation is valid for the following programmable safety systemsfrom the PSS SB2 3006-3 series:•PSS SB2 3006-3 DP-S from Version 1.0•PSS SB2 3006-3 IBS-S from Version 1.0•PSS SB2 3006-3 CN-A from Version 1.0•PSS SB2 3006-3 DN-S from Version 1.0•PSS SB2 3006-3 ETH-2 from Version 1.0•PSS SB2 3006-3 ETH-2 DP-S from Version 1.0•PSS SB2 3006-3 ETH-2 IBS-S from Version 1.0It is valid until new documentation is published. The latest documentationis always enclosed with the unit.Overview of documentation1IntroductionThe introduction is designed to familiarise you with the contents,structure and specific order of this manual.2OverviewThis chapter provides information on the most important features ofthe programmable safety systems.3SafetyThis chapter must be read as it contains important information onsafety regulations and intended use.4Function DescriptionThis chapter describes the individual components of theprogrammable safety systems: CPU, inputs and test pulse outputs.5InstallationThis chapter explains how to install the programmable safetysystems.6Supply VoltageThis chapter explains what you need to consider when connecting thesupply voltage.7Wiring the Inputs and Test Pulse OutputsThis chapter describes the safety-related wiring of the inputs and testpulse outputs.8InterfacesThis chapter describes the configuration of the available interfaces.9Operation and MaintenanceThis chapter explains how to commission the safety systems andadvises on what to do if a fault occurs.10Technical Details11AppendixIntroductionOverviewOverviewAUTO PGSTFSPSS SB2 3006-3 DP-S4F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 IBS-S4F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 CN-A 4F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 DN-S 4F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 ETH-24F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 ETH-2 DP-S 4F-StackOverviewAUTO PGSTFSPSS SB2 3006-3 ETH-2 IBS-S 4F-StackPG 6OverviewSafetySafetyDigital inputs (DI2)Depending on the application area and its respective regulations, the PSSmay be used without test pulses for applications up to category 3in accordance with EN 954-1 (03/97). The possibility of a short circuitoccurring in the external wiring between different inputs or to L+ must beeliminated through appropriate wiring.T est pulses must be used for category 4 applications (for connectionexamples please see Chapter 7, “Wiring the Inputs and T est PulseOutputs”).Safety guidelinesFailure to keep to these guidelines will render all warranty and liabilityclaims invalid:•All health and safety / accident prevention regulations for the particulararea of application must be observed.•Before using the unit it is necessary to perform a safety assessment inaccordance with the Machinery Directive 98/37/EC.Use of qualified personnelThe safety system may only be assembled, installed, programmed,commissioned, operated, maintained and decomissioned by qualifiedpersonnel. Qualified personnel are people who, because they are:•Qualified electrical engineers and• Have received training from qualified electrical engineers,are suitably experienced to operate devices, systems, plant and machineryin accordance with the general standards and guidelines for safetytechnology.SafetyEMCDThe safety system is designed for use in an industrial environment.Interference may occur if used within a domestic environment. Warranty and liabilityAll claims to warranty and liability will be rendered invalid if:•The safety system was used contrary to the purpose for which it wasintended•Damage can be attributed to not having followed the guidelines in themanual•Operating personnel are not suitably qualified.•Any type of modification has been made (e.g. exchanging componentson the PCB boards, soldering work etc.).DisposalThe programmable safety system must be disposed of properly when itreaches the end of its service life.Function DescriptionCPUThe CPU controls the test pulse outputs, reads the inputs and processes /stores the user program and variable data. The failsafe section is designedto be multi-channel, i.e. different CPUs process the user programindependently.A four-digit display and several LEDs provide information on the status ofthe safety system and indicate any errors.Function DescriptionInterfacesCPU interfacesThe CPU of each programmable safety system in the PSS SB2 3006-3series provides the following interfaces:•Programming device interfaceCombined RS 232 interface (minimum configuration: TxD, RxD, GND)/RS 485•User interfaceCombined RS 232/RS 485 interfaceFor further information please refer to the “System Manual for thePSS-Range”.SafetyBUS p interfaceEach programmable safety system in the PSS SB2 3006-3 series has twoSafetyBUS p interfaces.The second SafetyBUS p interface can be used to divide up large plants.This can help to optimise the reaction time.For further information on SafetyBUS p, please refer to the “SystemManual for SafetyBUS p”.Interfaces for standard bus systemsDifferent interfaces are available for connection to various standard bussystems, depending on the unit type. The standard bus interfaces aredescribed in separate operating manuals. The necessary operatingmanuals are supplied with the relevant unit types.Digital inputs (DI2)All programmable safety systems in the PSS SB2 3006-3 series have sixintegral on-board inputs, which are suitable for connecting single and dual-channel input devices, with or without test pulses. Input signals must showa “High” (“1” signal) of 24 VDC (+15 ... +30 VDC) and a “Low” (“0” signal)of 0 VDC (-3 ... +5 VDC).LEDs are used as status indicators. An LED lights up as soon as a “1”signal is present at the input. All inputs have input filters.Internal diagnostic circuitry checks the function of the inputs, including theinput filter. If an error occurs, the PSS will switch to a STOP condition andoutput a message to the CPU display. In addition, all the decentralisedoutputs in the I/O-Groups assigned to the PSS Logic Device will beswitched off (see also “SafetyBUS p System Description”).Where test pulses are not used, inputs with single-channel input devicescan be used in applications up to and including Category 2 in accordancewith EN 954-1; in the case of dual-channel input devices, this extends toCategory 3 applications. The device should be suitably wired to eliminatethe risk of a short circuit in the external wiring between the different inputsand also between the PSS supply and any bus interface.Test pulses must be used for applications with single-channel inputdevices above Category 2 and for applications with dual-channel inputdevices above Category 3. Connection examples can be found in Chapter 7of this manual, “Wiring the Inputs and Test Pulse Outputs”.Function DescriptionInstallationInstallationAUTO PG STFS PSS SB 3006-3 DP-S F-StackST FSST FSInstallationSupply VoltageSupply VoltageSupply VoltageSupply VoltageNotes on wiring•Minimum range for cable cross sections on field connection terminals inmm2, in accordance with EN 61131-2, 07/00:-Power supply: 1.5 (AWG16) ... 2.5 (AWG12)-Functional earth: 1.5 (AWG16) ... 2.5 (AWG12)•Use copper wiring.•The torque setting on the terminals should be 0.5 … 0.6 Nm.Wiring the Inputs and Test Pulse Outputs AUTO PG ST FS PSS SB2 3006-3 IBS-S F-StackWiring the Inputs and Test Pulse Outputs•Connecting and laying the cables-Screened cables are not required for digital I/Os. However, if theconnection cables have screening, it should be connected at one end. -Minimum range for cable cross sections on field connection terminals in mm2, in accordance with EN 61131-2, 07/00:¤Digital inputs:0.5 (AWG20) ... 1.5 (AWG16)¤Test pulse outputs:0.5 (AWG20) ... 1.5 (AWG16)¤Power supply: 1.5 (AWG16) ... 2.5 (AWG12)¤Functional earth: 1.5 (AWG16) ... 2.5 (AWG12)-If you use a multi-strand cable with a cross section of 1.5 mm2 toconnect the inputs and test pulse outputs, you will need to use ferrules conforming to DIN 46228, Part 1 and Part 2 0.5 ... 1.5 mm2, Form A orC. To crimp the ferrules you can use crimp pliers (crimp form A or C)conforming to EN 60947-1, such as the PZ 1.5 or PZ 6.5 fromWeidmüller, for example.-Use copper wiring.-The torque setting on the terminals should be 0.5 … 0.6 Nm.The terms “signal inputs with frequent operation” and “single-channel safe input devices” are used in the wiring examples. These terms are defined as follows:•Signal inputs with frequent operationThese are signals which change status on several occasions within a period of time.•Single-channel safe input devicesThese are positively-driven, normally-closed contacts which open on actuation (failsafe principle).Wiring the Inputs and Test Pulse Outputs。

机房配套设备清单

机房配套设备清单

机房配套设备清单
要求:1、供应商报价中要包含商品全部的运输、安装调试、辅材、税费等全部费用; 2、提供的产品必须为原装产品,3包齐全,全国联保。

若提供的是假冒伪劣产品,需按合同的金额全额退款并赔偿由此造成的一切损失; 3、明确中标单位后,中标单位须派人送货到工程地点进行设备安装及调试,不得使用快递或者客户自提等方式发货; 4、为方便供货和保证本地化及时售后服务质量,本次竞价限福州本地供应商或在福州本地有销售或售后服务网点的外地供应商参与(外地经销商需提供本地营业执照等相关材料);5、签合同前需对所投设备(机柜、KVM系统、环境监测系统)提供三年的免费保修维护的原厂售后服务承诺函原件(需上传文件),若无法提供则视为自动放弃。

6.供应商在竞价时须以附件形式上传相关资质证明: 包括营业执照、原厂售后服务承诺函。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

1/63
TABLE OF CONTENTS Summary Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
t( I/O Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 c JTAG ISP Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 du Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Pro t(s) Security and NVM Sector Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 te c Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 sole rodu Typical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 b P Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ) - O lete Specifying Mem Map with PSDsoft ExpressTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ct(s bso Runtime control register definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 du - O Detailed Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Pro t(s) Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 te c Instruction Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 le du Reading Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 so ro Programming Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ob te P Erasing Flash Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 le Flash Memory Sector Protect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 soDSM Security Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 ObReset Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
PQFP52 (T)
PLCC52 (K)
■ In-System Programming (ISP) with JTAG – Program entire chip in 10-20 seconds with no involvement of the DSP – Eliminate sockets for pre-programmed memory and logic devices – Efficient manufacturing allows easy produc testing and Just-In-Time inventory – Use low-cost FlashLINKTM cable with PC
Figuemory, logic, and I/O to DSP
■ 128K Byte Flash Memory
– For Bootloading and/or Data Overlay Memory
t( – Programmable Decoding and Paging Logic c allows accessing Flash memory as Byte DMA du (BDMA) and as External Data Overlay memro ) ory P t(s – Rapidly access Flash memory with BDMA for te c booting and loading internal DSP Overlay le u memory. Alternatively access the same Flash d memory as External Data Overlay memory to so ro efficiently write Flash memory with code upb P dates and data, a byte at a time with no DMA - O te setup overhead ) le – Individual 16K Byte Flash memory sectors t(s o match size of DSP External Data Overlay s window for efficient data management. Intec b grated page logic provides easy DSP access du - O to all 128K Bytes. ro ) – DSM connects to lower byte of 16-bit DSP P t(s data bus. Byte-wide accesses to 8-bit BDMA te c space. Half-word accesses to 16-bit Data le u Memory Overlay and 16-bit I/O Mem space. so rod ■ 3.3V Devices (±10%)
DSM2180F3V
DSM (Digital Signal Processor System Memory) for analog devices ADSP-218X family (3.3 V supply)
相关文档
最新文档