低剂量容积数据高分辨率CT应用于肺部体检的参数优化
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
低剂量容积数据高分辨率CT应用于肺部体检的参数优化吴伟军;申敏;赵志宇;蔡恩明;蒋蕴毅
【期刊名称】《海南医学》
【年(卷),期】2016(0)22
【摘要】目的:探讨低剂量容积数据高分辨率CT (VHRCT)应用于肺部体检扫描的最佳参数。
方法将本院2013年10月至2015年7月500名肺部健康体检者简单随机化分成5组,各组100名,管电流分别为常规剂量220 mA和低剂量35 mA、30 mA、25 mA、20 mA,管电压均为120 kV扫描,容积数据进行薄层高分辨率算法重组,以能显示肺小叶水平上的细微结构和病变以及大血管的边界为保证诊断质量的图像。
记录各组受检者的照射剂量,对不同低剂量管电流和常规剂量的VHRCT图像进行统计学分析。
结果35 mA、30 mA、25 mA、20 mA低剂量与常规剂量220 mA相比,受检者的照射剂量分别下降85.64%、87.86%、90.24%、92.53%。
35 mA、30 mA、25 mA和220 mA常规剂量VHRCT图像比较差异均无统计学意义(P<0.05),20 mA和常规剂量比较差异有统计学意义(P<0.05)。
结论25 mA的管电流可作为低剂量容积数据高分辨率CT应用于肺部体检的参考条件。
%Objective To study the optimal parameters low-dose volumetric data with a high-resolution CT al-gorithm (VHRCT) for lung physical examination. Methods A total of 500 cases of lung physical examinations in our hospital from October 2013 to July 2015 were randomly divided into 5 groups, with 100 cases in each group. The 5 groups were scanned by VHRCT with the different parameters as follows:tube voltage was 120 kV;tube current were re-spectively regular
dose of 220 mA and low-dose of 35 mA, 30 mA, 25 mA, 20 mA;thin-recon-struction of volumetric data with a high-resolution algorithm was used to ensure the quality of diagnostic images to show the small structure and lung lobules level of lesion and the boundary of the great vessels. The radiation dose of each group of subjects was re-corded, and the VHRCT images of different low-dose tube currents and conventional doses were analyzed statistically. Results Compared with the low-dose of 35 mA, 30 mA, 25 mA, 20 mA, the radiation dose of the conventional dose of 220 mA decreased respectively by 85.64%, 87.86%, 90.24%, 92.53%. There was no significant difference between the low-dose of 35 mA, 30 mA, 25 mA and conventional dose of 220 mA in the VHRCT image (P>0.05), while there was significant difference between the low-dose of 20 mA and conventional dose of 220 mA in the VHRCT image (P<0.05). Conclusion The 25 mA tube current scan can be used as a reference of low-dose volumetric data with a high-resolution CT algorithm for lungs physical examination.
【总页数】3页(P3690-3692)
【作者】吴伟军;申敏;赵志宇;蔡恩明;蒋蕴毅
【作者单位】上海市嘉定区安亭医院放射科,上海 201805;上海市嘉定区安亭医院放射科,上海 201805;上海市嘉定区安亭医院放射科,上海 201805;上海市嘉定区安亭医院放射科,上海 201805;上海市嘉定区安亭医院放射科,上海 201805【正文语种】中文
【中图分类】R445
【相关文献】
1.16层螺旋CT低剂量薄层肺部体检与常规胸片肺部体检对病变检出率的对比研究[J], 孙木水;陈锦福;刘高;马杰
2.低剂量容积数据高分辨率CT重组在肺部疾病中的应用价值 [J], 温涛;段磊;蔡敏;岳园;许维亮
3.螺旋CT低剂量薄层肺部体检与常规胸片肺部体检对病变检出率的对比研究 [J], 冯志清;李元
4.肺泡蛋白沉积症低剂量容积数据高分辨率CT影像特征分析 [J], 杨帆; 肖正远; 温晓玲
5.低剂量容积数据高分辨率CT重组对无症状吸烟者肺部损害分析 [J], 周福兴因版权原因,仅展示原文概要,查看原文内容请购买。