Safinamide_133865-89-1_DataSheet_MedChemExpress
超米特电子有限公司产品说明书
1US Headquarters TEL +(1) 781-935-4850FAX +(1) 781-933-4318 • Europe TEL +(44) 1628 404000FAX +(44) 1628 404090Asia Pacific TEL +(852) 2 428 8008FAX +(852) 2 423 8253South America TEL +(55) 11 3917 1099FAX +(55) 11 3917 0817Superior elongation and tensilestrength help to prevent tearing in use due to mishandling. Typical properties for CHO-SEAL 1310 and 1273 materi-al are shown on pages 33 and 32respectively.High Shielding PerformanceCHO-SEAL 1310 material provides more than 80 dB of shielding effectiv-ness from 100 MHz to 10 GHz, while CHO-SEAL 1273 material provides more than 100 dB.Low Volume ResistivityBoth materials have exceptionally low volume resistivity, which makes them well suited for grounding appli-cations in which a flexible electrical contact is needed.Low Compression GasketSpacer gaskets are typicallydesigned to function under low deflec-tion forces. Chomerics uses design tools such as Finite Element Analysis (FEA) to accurately predict compres-sion-deflection behavior of various cross section options. Refer to page16.LCP Plastic SpacerLiquid crystal polymer (LCP)spacers, including those made with Vectra A130 material, provide aCHO-SEAL ®1310 or 1273Conductive ElastomersWith EMI spacer gaskets, shielding and grounding are provided by Chomerics’CHO-SEAL 1310 and 1273 conductive elastomers, specifi-cally formulated for custom shape molded parts. They provide excellent shielding and isolation against electro-magnetic interference (EMI), or act as a low impedance ground path between PCB traces and shielding media. Physically tough, these elas-tomers minimize the risk of gasket damage, in contrast to thin-walled extrusions or unsupported molded gaskets.Silicone-based CHO-SEAL 1310and 1273 materials offer excellent resistance to compression set over a wide temperature range, resulting in years of continuous service. CHO-SEAL 1310 material is filled with silver-plated-glass particles, while 1273 utilizes silver-plated-copper filler to provide higher levels of EMI shielding effectiveness.EMI Spacer GasketsThe unique design of Chomerics’EMI spacer gaskets features a thin plastic retainer frame onto which a conductive elastomer is molded. The elastomer can be located inside or outside the retainer frame, as well as on its top and bottom surface. EMI spacer gaskets provide a newapproach to designing EMI gaskets into handheld electronics such as dig-ital cellular phones. Board-to-board spacing is custom designed to fit broad application needs. Customized cross sections and spacer shapes allow for very low closure forcerequirements and a perfect fit in any design or device.Robotic InstallationSpacer gaskets can be installed quickly by robotic application. Integral locater pins in the plastic spacer help ensure accuratepositioning in both manual and pick-and-place assembly. Benefits include faster assembly and lower labor costs.The integrated conductive elastomer/plastic spacer gasket is a low cost,easily installed system for providing EMI shielding and grounding in small electronic enclosures.Figure 1Single Piece EMI Gasket/Locator PinsCHO-SEAL 1310 or 1273 Conductive Elastomer (Inside)Plastic Spacer Around Outsideor InsideApplications for EMI Spacer GasketsThe spacer gasket concept is especially suited to digital and dual board telephone handsets or other handheld electronic devices. It provides a low impedance path between peripheral ground traces on printed circuit boards and components such as:•the conductive coating on a plastic housing•another printed circuit board •the keypad assemblyTypical applications for EMI spacer gaskets include:•Digital cellular, handyphone and personal communications services (PCS) handsets •PCMCIA cards•Global Positioning Systems (GPS)•Radio receivers•Other handheld electronics, e.g.,personal digital assistants (PDAs)•Replacements for metal EMI shield-ing “fences” on printedcircuit boards in wireless tele-communications devicesstable platform for direct, highprecision molding of conductive elas-tomers. The Vectra A130 material described in Table 1 has excellent heat deflection temperature character-istics (489°F, 254°C). For weight con-siderations, the LCP has aspecific gravity of only 1.61. This plas-tic is also 100% recyclable.Typical EMI Spacer Gasket Design ParametersThe EMI spacer gasket concept can be considered using the design parameters shown in Table 2. Some typical spacer gasket profiles are shown below.Figure 2Typical Spacer Gasket Profiles3US Headquarters TEL +(1) 781-935-4850FAX +(1) 781-933-4318 • Europe TEL +(44) 1628 404000FAX +(44) 1628 404090Asia Pacific TEL +(852) 2 428 8008FAX +(852) 2 423 8253South America TEL +(55) 11 3917 1099FAX +(55) 11 3917 0817Finite Element AnalysisChomerics, a division of the Parker Hannifin Corporation’s Seal Group, is the headquarters of Parker Seal’s Elastomer Simulation Group. This unit specializes in elastomer finite element analysis (FEA) using MARC K6 series software as a foundation for FEA capability.Benefits of FEA include:•Quickly optimizing elastomer gasket designs•Allowing accurate predictions of alternate elastomer design concepts •Eliminating extensive trial and error prototype evaluationTypical use of FEA in EMI spacer gasket designs is to evaluate the force vs. deflection requirements of alternate designs.For example, onespacer design features a continuous bead of con-ductive elastomer molded onto a plastic spacer. An alternative designemploys an “interrupted bead,” where the interrup-tions (gaps left on the plastic frame) are sized to maintain the requiredlevel of EMI shielding. Figure 4illustrates these alternative designs.Gasket DeflectionFigure 5 compares the effect of continuous and interrupted elastomer gasket designs in terms of the force required to deflect the conductive elastomer. This actual cellular handset application required a spacer gasket with interrupted bead to meet desired deflection forces.Chomerics Designand Application ServicesChomerics will custom design a spacer for your application. Advice,analysis and design assistance will be provided by Chomerics Applications and Design engineers at no additional fee. Contact Chomerics directlyat the locations listed at the bottom of the page.Figure 3FEA Example of an EMISpacer Gasket Cross SectionFigure 4Continuous (top) and InterruptedElastomer GasketsFigure 5Typical Spacer Gasket Deflection。
CONTRINEX AG工业电子产品数据表-安全继电器YRB-4EML-31S用于安全光幕 屏障类型
DATA SHEETSAFETY RELAYYRB-4EML-31SFOR SAFETY LIGHT CURTAINS/BARRIERSTYPE 4 SAFETY PROTECTION DEVICETECHNICAL DATAAPPLICATION AREAThe safety relay can be used to monitor electrosensitive protective equipment with monitored active switching output (OSSD) in accordance with EN 61496 as well as emergency stop and safety door locking mechanisms.Depending on the external wiring, up to category 4, PL e according to EN ISO 13849-1 or SILCL 3 according to EN 62061 can be achieved.The safety relay is equipped with three enabling current paths that drop out without delay corresponding to stop category 0 according to EN 60204-1.–For safety light curtains and access control bar-riers, emergency stop, door switch –Safety Integrity Level (SIL) 3 according to IEC/EN 61508 –Claimed Level (SIL CL) 3 according to IEC/EN 62061 –Performance Level (PL) e and category 4 ac-cording to EN/ISO 13849-1 –Safety category 4 according to EN 954-1–Certified TÜV , CE and UL–Output: 3 N.O. safety contacts / 1 N.C. monitor-ing contact –Manual or automatic restart–LED indicator for channel 1, 2 and power supply –22.5 mm wide, DIN-rail-mountable housingMAIN FEATURESFigure 1 Derating curveTECHNICAL DATADATA SHEETYRB-4EML-S41_E.indd / page 1-2 / rev. 1 / 27.01.16 / MDMDATA SHEETPART REFERENCESTRUCTURE AND OPERATION (BLOCK DIAGRAM)WARNING: Risk of electric shockDuring operation, parts of electrical switching devices carry hazardous voltages.Before working on the switching device, disconnect the power.Please observe the safety regulations of electrical engineering and industrial safety and liability associations!Disregarding these safety regulations may result in death, serious personal injury or damage to equipment.Startup, mounting, modifications, and upgrades should only be carried out by a skilled electrical engineer!WARNING: Risk of automatic machine restart!For emergency stop applications, the machine must be prevented from restarting automatically by a higher-level controlsystem.Protective covers must not be removed when operating electrical switching devices.WARNING: Danger due to faulty devices!The devices may be damaged following an error and correct operation can no longer be ensured.In the event of an error, replace the device immediately.Repairs to the device, especially if the housing must be opened, may only be carried out by the manufacturer or autho-rized persons. Otherwise the warranty is invalidated.NOTE: Risk of damage to equipment due to incorrect installation!For reliable operation, the safety relay must be installed in housing protected from dust and humidity (IP 54).Carry out wiring according to the application. Refer to the “Application examples” section for this.NOTE: Risk of damage to equipment due to noise emissionsWhen operating relay modules the operator must meet the requirements for noise emission for electrical and electronic equipment (EN 61000-6-4) on the contact side and, if required, take appropriate measures.For the diagnostic description, please refer to the application manual for PSR safety relays.SAFETY NOTESFigure 2 Block diagramDATA SHEETKEYTwo-channel light grid monitoring (cross-circuit detection via light grid)– Manual activation– Automatic activation with jumper at S33-S35– Suitable up to category 4, PL e (EN ISO 13849-1), SILCL 3 (EN 62061)APPLICATION EXAMPLEFigure 4 Two-channel light grid monitoringOPERATING AND INDICATION ELEMENTSFigure 3 YRB-4EML-31SYRB-4EML-31SYRB-4EML-S41_E.indd / page 3-4 / rev. 0 / 19.11.15 / MDMDATA SHEETAPPLICATION EXAMPLETwo-channel emergency stop circuit without cross-circuit detection, with monitored reset button– Manual activation– Automatic activation with jumper at S33-S35– Suitable up to category 3, PL d (EN ISO 13849-1), SILCL 2 (EN 62061)Single-channel emergency stop monitoring– Manual activation– Automatic activation with jumper at S33-S35– Suitable up to category 1, PL c (EN ISO 13849-1), SILCL 1 (EN 62061)Two-channel safety door monitoring without cross-circuit detection, with monitored reset button– Manual activation– Automatic activation with jumper at S33-S35– Suitable up to category 3, PL d (EN ISO 13849-1), SILCL 2 (EN 62061)Figure 5 Two-channel emergency stop circuit without cross-circuit detectionFigure 6 Single-channel emergency stop circuit with monitored reset buttonFigure 7 Two-channel safety door monitoring without cross-circuit detectionYRB-4EML-31SYRB-4EML-31SYRB-4EML-31SYRB-4EML-S41_E.indd / page 5 / rev. 0 / 19.11.15 / MDM。
接触碟产品目录
5
产品规格
90 mm 预灌装培养基平皿:用于空气中沉降菌的测定以及实验室 相关微生物指标的测定等。 75 mm 预灌装培养基平皿:用于 MILLIPORE 浮游生物检测仪配 套使用。 55 mm 预灌装培养基接触性平皿(Rodac Plate 接触碟) :用于设 备、车间、人员、包装材料等表面微生物的测定。
海南办事处 海口市南沙路 78 号南沙公寓 320 室 570206 电话: (0898)66703090 传真: (0898)66703090
8
2
产品用途
本品适用于物品表面(洁净厂房、机械设备、洁净服、包装材料等)表 面微生物的检测。广泛应用于制药、食品、医院以及化妆品等企事业单位 的环境微生物检测,比传统的棉签方法更简便、准确。可用于对洁净环境 中的微生物进行动态/静态监测,以及检验消毒效果等。
培养基种类(进口) :
∗ 胰蛋白大豆琼脂(TSA) ∗ 含卵磷脂及吐温 80 胰蛋白大豆琼脂(TSAWLP) ∗ 沙堡氏琼脂(SDA) ∗ 麦康凯琼脂(MCA) ∗ 营养琼脂 NA ∗ 玫瑰红纳琼脂 RBA、R2A 等 可在培养基中添加青霉素酶等催化酶,用于去除生产中产生的抗生素 粉尘的抗菌性。
江苏益玛生物科技有限公司(EM-BIO) ,成立于 2011 年 7 月,注册资
金 500 万元。公司创建于国内唯一的国家级医药产业园区——江苏泰州・中国医 药城,是国内首家与国外著名制药企业合作,按照欧盟 EMEA 标准,开发无菌环 境检测产品的民营企业;公司紧跟新版 GMP 要求,研发出高水平、高质量的预灌 装培养基平皿系列产品,产品的灌装及包装等主要环节,均在 B 级背景下的 A 级 半隔离器中完成,为国内首创。产品经与国际知名企业产品对照试验,性能优良, 反应灵敏,品质稳定,完全达到欧盟相关技术要求。目前,已有多家国内外知名 药企使用本公司产品。
Pepperl+Fuchs SJ3,5-N 产品说明书
17-02-16 15:19D a t e o f i s s u e : 2017-02-16105910_e n g .x m lInstructionManual electrical apparatus for hazardous areas Device category 1Gfor use in hazardous areas with gas, vapour and mist EC-T ype Examination CertificateCE marking ATEX marking ¬ II 1G Ex ia IIC T6…T1 G aThe Ex-related marking can also be printed on the enclosed label.Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety"Use is restricted to the following stated conditions Appropriate typeSJ3,5-...-N...Effective internal inductivity C i ≤ 50 nF ; a cable length of 10 m is considered.Effective internal inductance L i≤ 250 µH ; a cable length of 10 m is considered.G eneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EU-type examination certificate has to beobserved. The special conditions must be adhered to! The ATEX directive and there-fore the EU-type examination certificates are in general only applicable to the use of electrical apparatus operating at atmospheric conditions. The device has been checked for suitability for use at ambient temperatures of >60°C by the named certification authority. The surface temperature of the device remains within the required limits. If the equipment is not used under atmospheric conditions, a reduc-tion of the permissible minimum ignition energies may have to be taken into consid-eration.Highest permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum per-missible ambient temperature, the temperature class, and the effective internal reac-tance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appro-priate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Because of the risk of igni-tion, which can occur due to faults and/or transient currents in the equipotential bonding system, galvanic isolation is preferable in the supply and signal circuits. Associated apparatus without electrical isolation can only be used if the correspond-ing requirements of IEC 60079-14 are satisfied. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicin-ity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion.Maintenance No changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsThe connecting parts of the sensor must be set up in such a way that degree of pro-tection IP20, in accordance with lEC 60529, is achieved as a minimum.Protection from mechanical dangerWhen using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed.R e l e a s e d a t e : 2017-02-16 15:19D a t e o f i s s u e : 2017-02-16105910_e n g .x m lInstructionManual electrical apparatus for hazardous areas Device category 2Gfor use in hazardous areas with gas, vapour and mist EC-T ype Examination CertificateCE marking ATEX marking ¬ II 1G Ex ia IIC T6…T1 G aThe Ex-related marking can also be printed on the enclosed label.Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety"Use is restricted to the following stated conditions Appropriate typeSJ3,5-...-N...Effective internal inductivity C i≤ 50 nF ; a cable length of 10 m is considered.Effective internal inductance L i ≤ 250 µH ; a cable length of 10 m is considered.G eneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EU-type examination certificate has to be observed. The special conditions must be adhered to!Maximum permissible ambient temperature T amb Details of the correlation between the type of circuit connected, the maximum per-missible ambient temperature, the temperature class, and the effective internal reac-tance values can be found on the EU-type examination certificate.Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appro-priate related apparatus and according to the proof of intrinsic safety. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indeli-ble, including in the event of possible chemical corrosion.Maintenance No changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsThe connecting parts of the sensor must be set up in such a way that degree of pro-tection IP20, in accordance with lEC 60529, is achieved as a minimum.Protection from mechanical dangerWhen using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed.17-02-16 15:19D a t e o f i s s u e : 2017-02-16105910_e n g .x m lInstructionManual electrical apparatus for hazardous areas Device category 1Dfor use in hazardous areas with combustible dust EC-T ype Examination CertificateCE marking ATEX marking ¬ II 1D Ex ia IIIC T135°C DaThe Ex-related marking can also be printed on the enclosed label.Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety"Use is restricted to the following stated conditions Appropriate typeSJ3,5-...-N...Effective internal inductivity C i ≤ 50 nF ; a cable length of 10 m is considered.Effective internal inductance L i≤ 250 µH ; a cable length of 10 m is considered.G eneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EU-type examination certificate has to beobserved. The ATEX Directive and therefore the EU-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. The device has been checked for suitability for use at ambient temperatures of > 60 °C by the named certification authority. For the use of apparatus outside of atmo-spheric conditions, a reduction of the permissible minimum ignition energies may need to be considered.Highest permissible ambient temperature T ambDetails of the correlation between the type of circuit connected, the maximum per-missible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maxi-mum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appro-priate related apparatus and according to the proof of intrinsic safety. Install the device in such a way that the resin surface is not exposed to mechanical hazards. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indeli-ble, including in the event of possible chemical corrosion.Maintenance No changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsThe connecting parts of the sensor must be set up in such a way that degree of pro-tection IP20, in accordance with lEC 60529, is achieved as a minimum.Protection from mechanical dangerWhen using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed.Electrostatic chargeAvoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the techni-cal specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.。
索拉特龙S系列位移传感器产品手册说明书
Since 1970Distributing Tomorrow’s Technologies For Today’s DesignsToll-Free: 1-800-777-7334/solartronDatasheet502686issue 7EDCR 18768 S-SeriesDisplacement Transducers• <0.2% Linearity FSO• 19mm Diameter Stainless Steel Body• IP 65 or IP 67 Protection• Improved measuring range to body length• AC, DC, 4-20mA and Digital output versions• Large Bore to core clearance• Wide range of instruments & signal conditioningThe S-Series of Displacement Transducers is the culmination of many years of experience gained from Solartron Metrology’s highly successful Mach One range plus careful note of market feed-back. The result is a totally new range of transducers that is better able to satisfy today’s demand-ing manufacturing and research applications.The need to transfer signals from the transducer to data acquisition and control systems reliably, quickly and cost effectively has been catered for with a complete new range of onboard or external analogue signal conditioning units and Orbit® compatible modules for Digital versions.The Stainless Steel body with improved sealing options of IP65 or IP67, coupled with new polymer guides with rigid carriers, ensure that the transducers keep working accurately and reliably, espe-cially in wet or corrosive conditions.An unusually large bore to core clearance is maintained throughout the range, even on transducers fitted with onboard signal conditioning, enabling easier installation and making the assembly more forgiving of misalignment.S IP 65S IP 67S RS ub m e r s i b l e S R I P 68A x i a l C o n n ec t o rL V D TD CO r b i t 4-20m A S c r e wM o u n tH i g hT e m p 'Measuring range 5 (total travel mm)1015203050100150200300MechanicalAxial connector Free Core Guided core Screw Mount High Temp,Display/ControllerSI 1000SI 3000SI 7000Remote DRC signal conditioning OD 2OD 4Note! High Temperature OD 5is for Transducers onlyBICM (15-0-15V)BICM (24V)Compatible TTL module Refer to Engineering OrbitNot Availablemeasuring range in mmLVDT +/- 2.5 +/- 5.0 +/- 7.5 +/- 10 +/- 15 +/- 25 +/- 50 +/- 75 +/- 100 +/- 150DC/DC & 4-20 mA 0-50-100-150-200-300-500-1000-1500-2000-300Digital 0-50-100-150-200-300-500-1000-1500-2000-300Linearity FSO0.20.25Electrical LVDT Sensitiv ity (mV/V/mm) ± 5%3V RMS at 5.0kHz into 100k ohm 145179121766021.51510.56.93.9Energising current (mA/V) ± 5%1.02.62.20.61.50.50.62.51.651.83Residual Voltage at null (%FSO)<0.5<0.5<0.5<0.5<0.5<0.5<0.5<0.5<0.5<0.5Electrical DC/DC & 4-20mA Input Voltage (DC)10-30V Output ripple (%FSO)0.02Bandwidth Hz (-3dB)500Environmental (transducer only)Storage temperature LVDT -40ºC to +120ºC Electrical Digital Storage temperature DC/DC & 4-20mA -20ºC to +85ºC Reading rate Up to 3906 readings per second Operating temperature LVDT -40ºC to +120ºC Bandwidth Up to 460 Hz Operating temperature DC/DC & 4-20mA 0ºC to +65ºC OutputSolartron Orbit ProtocolOperating temperature Digital* (probe only) -40ºC to +120ºC Sealing IP 67 or IP 65 Mechanical Options temperature coefficient (%FSO/ºC). Guided core <02 for +/-2.5mm. <.015 rest of range Spring return Shock Drop test 1m onto hard surface Connectors topple test x 10 onto hard surface Extra cable Vibration Sinusoidal Amplitude Univ ersal Joints see 10 to 50Hz 1-10 grms linear Output options ordering 50 to 1kHz 10 grmsguideMaterialBody 316 series Stainless Steel Core Nickel/Iron CableFEP0-10 V dc 10-0 V dc 4-20 mA 20-4 mA+/- 5 Vdc +/- 10 Vdc 0-5 V dc 5-0 V dcSince 1970Distributing Tomorrow’s Technologies For Today’s DesignsToll-Free: 1-800-777-7334/solartronGuided with Universal Joints‘A’ mm‘B1’ mm‘B2’ mm‘B3’ mmBody length Fully At null Retracted A/C Extended± 2.5 mm5553.2549.545.4± 5 mm74.564.255749.4± 7.5mm81.768.2559.951.2± 10 mm9679.2566.853.9± 15 mm110.497.2576.355± 25 mm131.9120.2589.157.5± 50 mm189.5178.2512469.4± 75 mm239.7249.25169.990.2± 100 mm297.2309.23201.1893.08± 150 mm412475309.5141.73 DC/DC & 4-20 mA5 mm9453.2549.545.4 10 mm113.564.255749.4 15 mm120.768.2559.951.2 20 mm13579.2566.853.9 30 mm149.497.2576.35550 mm170.9120.2589.157.5 100 mm228.5178.2512469.4 150mm278.7249.25169.990.2 200mm336.2309.23201.1893.08 300 mm450.9475309.5141.73 Guided with Universal JointsSince 1970Distributing Tomorrow’s Technologies For Today’s DesignsToll-Free: 1-800-777-7334/solartronFree core & Carrier‘A’ mm 'B' mm 'C' mm D' mmA/C body length core length at null± 2.5 mm33.516.540.547± 5 mm53294858± 7.5mm60.23450.962± 10 mm74.54057.7573± 15 mm88.937.567.391± 25 mm110.438.580.05114± 50 mm16850115172± 75 mm218.250160.9243± 100 mm275.750192.15303± 150 mm390.550300.72469DC/DC & 4-20 mA5 mm72.516.540.54710 mm9229485815 mm99.23450.96220 mm113.54057.757330 mm127.937.567.39150 mm149.438.580.05114100 mm20750115172150mm257.250160.9243200mm314.750192.15303300 mm429.550300.72469Free Core & Free Core with Carrieree Core & Free Core with CarrierSince 1970Distributing Tomorrow’s Technologies For Today’s Designs Toll-Free: 1-800-777-7334/solartronFree Core & Carrier Axial ConnectorAlso Available at Solartron MetrologyAddresses for offices worldwide United Kingdom - Head Office Solartron Metrology Steyning Way Bognor Regis West Sussex PO22 9STTel: +44 (0) 1243 833333 Fax: +44 (0) 1243 833322 ***********************************China - Shanghai Solartron Metrology Rm 912, Metro TowerNo 30 Tian Yao Qiao Road Shanghai 200030Zhong Renmin GongheguoTel: +86 21 6426 8111 Fax: +86 21 6426 7054***********************************JapanSolartron Metrology 4-5-37 Kamiosaki Shinagawa-ku GermanyAmetek GmbHSolartron Metrology Division Rudolf-Diesel-Strasse 16 40670 MeerbuschTel: +49 (0) 2159 9136 500 Fax: +49 (0) 2159 9136 505 ****************************China - Beijing Solartron Metrology Rm 912, Metro TowerNo 30 Tian Yao Qiao Road Shanghai 200030Tel: +86 21 6426 8111 Fax: +86 21 6426 7054***********************************USA915 N.New Hope Road Suite C,Gastonia, NC 28054FranceSolartron MetrologyRond-point de l’Espine des Champs Buroplus - Bat. D Elancourt 78990Tel: +33 (0)1 30 68 89 50Fax: +33 (0)1 30 68 89 59 ************************************China - ChengduAMETEK ChengDu Rep Office Room 2408, Zongfu Building 35 Zongfu RoadChengdu, Sichun, 610016Tel: +86 28 8675 8111 Fax: +86 28 8675 8141***********************************Introducing Your Partners:Taking the lead time out of Solartron Gage Probes.Visit:/solartronMichael HaasComponent Distributors Inc. Sales Engineer Phone: 303-357-2732Email: ***********************Steven RushingComponent Distributors Inc. Sales Engineer Phone: 303-357-2730Email: *************************Bob KrantzSolartron Metrology Email: *********************。
Fluke 902 HVAC Clamp Meter Users Manual
®PN 2547887 May 2006 Rev. 1, 3/07© 2006-2007 Fluke Corporation. All rights reserved. Printed in China.All product names are trademarks of their respective companies.902HVAC Clamp MeterUsers ManualLIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, con-tamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service cen-ter to obtain return authorization information, then send the product to that Service Center with a description of the problem.THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDEN-TAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential dam-ages, this limitation of liability may not apply to you.Fluke CorporationP.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands11/99Table of ContentsTitle Page Introduction (1)Contacting Fluke (2)Safety Information (3)Symbols (5)Getting Acquainted with the Meter (6)Using the Meter (10)AC and DC Voltage Measurement (10)Resistance and Continuity (11)Microamps µA Measurement (12)Temperature (13)Capacitance (16)AC Current Measurement (16)Backlight (18)MIN MAX Recording Mode (18)Display HOLD (19)Auto Off (19)Maintenance (20)Cleaning the Meter (20)Battery Replacement (21)Specifications (23)Electrical Specifications (23)General Specifications (24)902Users ManualList of TablesTable Title Page1. 902 HVAC Clamp Meter Features (7)2. Display Features (9)List of FiguresFigure Title Page1. 902 HVAC Clamp Meter Features (6)2. Display Features (8)3. Testing a Flame Rod (13)4. Temperature Measurement (15)5. Proper AC Current Measurement (17)6. Battery Replacement (22)902Users Manual902 IntroductionThe Fluke 902 is a hand-held battery-operated HVAC Clamp Meter (“the Meter”) that measures:•AC current•DC current (up to 200 µA for flame rod testing)•AC and DC voltages•Capacitance•Resistance•Continuity•Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with:•Two AA alkaline batteries (installed)•Users Manual•Soft carrying case•TL75 Test Leads (one pair)•80BK Integrated DMM Temperature Probe902Users ManualContacting FlukeTo contact Fluke, call one of the following telephone numbers:USA: 1-888-99-FLUKE (1-888-993-5853)Canada: 1-800-36-FLUKE (1-800-363-5853)Europe: +31 402-675-200Japan: +81-3-3434-0181Singapore: +65-738-5655Anywhere in the world: +1-425-446-5500Or visit Fluke’s Web site at: . Register the Meter at: HVAC Clamp MeterFlukeContacting Safety InformationA “XW Warning” statement defines hazardous conditions and actions that could cause bodily harm or death.A “W Caution” statement identifies conditions and actionsthat could damage the Meter or the equipment under test.XW Read First: Safety InformationTo ensure safe operation and service of theMeter, follow these instructions:•Read the Users Manual before use andfollow all safety instructions.•Use the Meter only as specified in theUsers Manual; otherwise, the Meter'ssafety features may be impaired.•Avoid working alone so assistance can berendered.•Never use the Meter on a circuit withvoltages higher than 600 V or a frequencyhigher than 400 Hz fundamental. The Metermay be damaged.•Never measure ac current while the testleads are inserted into the input jacks.•Do not use the Meter or test leads if theylook damaged.•Use extreme caution when working aroundbare conductors or bus bars. Contact withthe conductor could result in electricshock.902Users Manual•Use caution when working with voltages above 60 V dc or 30 V ac rms or 42 V acpeak. Such voltages pose a shock hazard.•Clean the case with a damp cloth and mild detergent only. Do not use abrasives orsolvents.•To avoid false readings that can lead to electrical shock and injury, replace thebatteries as soon as the low batteryindicator (B)appears. As the Meter getsto the point where the low batteries affectthe readings, the Meter locks and nomeasurements can be made until thebatteries are changed.•Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1.•Adhere to local and national safety codes.Individual protective equipment must beused to prevent shock and arc blast injurywhere hazardous live conductors areexposed.HVAC Clamp MeterSymbolsSymbolsThe following symbols are found on the Meter or in this manual.,May be used on hazardous live conductorsW Risk of danger. Important information. See UsersManual.X Hazardous voltage. Risk of electric shock.T Double insulationB Battery)Complies with Canadian and US StandardsP Conforms to relevant European Union directivesJ Earth groundF DC (Direct Current)B AC (Alternating Current)~Do not dispose of this product as unsorted municipalwaste. Contact Fluke or a qualified recycler fordisposal.;Conforms to relevant Australian standardsN10140s Inspected and licensed by TÜV Product Services902Users ManualGetting Acquainted with the Meter Refer to Figures 1 and 2 and Tables 1 and 2 to become more acquainted with the Meter’s features.Figure 1. 902 HVAC Clamp Meter FeaturesHVAC Clamp MeterGetting Acquainted with the Meter Table 1. 902 HVAC Clamp Meter FeaturesNumber DescriptionA Backlight ButtonB Jaw ReleaseC Tactile BarrierD JawsE Hold ButtonF Rotary Switch:V DC and AC voltageP Resistance and continuityG DC microampsF Degrees Fahrenheit / degrees CelsiusL CapacitanceK AC currentG LCDH Min Max ButtonI AC/DC, °F/°C ButtonJ Input Terminals902Users ManualFigure 2. Display FeaturesHVAC Clamp MeterGetting Acquainted with the MeterTable 2. Display FeaturesNumber IndicationA Battery indicator -The batteries are low and need to be changed. XW Warning: To avoid false readings, which could lead to possible electric shock or personal injury, replace the batteries as soon as the battery indicator appears.B Indicates the presence of high voltageC Indicators for minimum and maximum recording modeD Display Hold is activeE VoltsF AmpsG °F - Degrees Fahrenheit °C - Degrees Celsius e - OhmsM - MicroampsN - MicrofaradsDC - Direct CurrentAC - Alternating Current902Users ManualUsing the MeterAC and DC Voltage MeasurementTo measure AC or DC voltage:1.Insert the test leads into the Meter.2.Turn the rotary switch to V.3.Press A to choose AC or DC voltage. The displayreflects the chosen voltage mode.e the test leads to take the measurement. The Meterreading appears on the display.NoteWhen a measured voltage is above 30 V,Z appears on the display. When the voltage dropsbelow 30 V, Z disappears.HVAC Clamp MeterUsing the MeterResistance and ContinuityTo measure resistance or continuity:XW WarningTo avoid false readings that can lead toelectrical shock and injury, de-energize thecircuit before taking the measurement.1.Insert the test leads into the Meter.2.Turn the rotary switch to P.3.Take the measurement. The resistance readingappears on the display.•If the resistance is shorted, the Meter beeps and shows a reading < 30 Ω.•If the resistance is open or exceeds the Meter’s range, the display reads OL.902Users ManualMicroamps µA MeasurementThe µA dc (G) function on the Meter is primarily for HVAC flame rod testing. To test a heating system flame rod (refer to Figure 3):1.Turn the heating unit off and locate the wire betweenthe gas-burner controller and the flame rod.2.Break this connection.3. Turn the rotary switch on the Meter to G.ing alligator clips, connect test leads between theflame sensor probe and control-module wire.5.Turn heating unit on and check the reading on theMeter.6.Refer to the heating unit documentation for what thedesired reading should be.HVAC Clamp MeterUsing the MeterFigure 3. Testing a Flame RodTemperatureThe Meter measures temperature in either Celsius (°C) or Fahrenheit (°F).To measure temperature (refer to Figure 4):902Users Manual1.Connect the 80BK Integrated DMM TemperatureProbe to the input jacks noting correct polarity of theprobe.2.Turn the rotary switch to F.3.Press A to select °C or °F. The display reflects thechosen temperature mode.4.Position the probe to take the measurement. Thereading appears on the display.NoteTo meet stated accuracy, the 80BK and Metermust be at the same temperature.XW WarningTo avoid possible electric shock DO NOT applythe probe tip to any conductor that is greaterthan 30 V ac, 42 V peak or 60 V dc to earth.Using the MeterFigure 4. Temperature MeasurementUsers ManualCapacitanceTurn off circuit power, then disconnect and discharge the capacitor before measuring capacitance. Turn the Meter’s rotary switch to capacitance (L).If the capacitor requires more discharging, diSC is displayed while the capacitor discharges. When measuring, be sure to note the correct polarity of the capacitor.AC Current MeasurementXW WarningTo avoid electrical shock and injury:•Remove Test Leads before making current measurements.•Do not hold the Meter anywhere beyondthe tactile barrier, see Figure 1.Turn the rotary switch to AC current (K). When measuring AC current, it is necessary that the measured wire be properly seated within the clamp jaws. The wire being measured should be centered within the jaws, below the horizontal line located on the clamp. Also note that currents moving in different directions will cancel each other out, so one wire must be measured at a time for a correct measurement (see Figure 5).Using the MeterFigure 5. Proper AC Current MeasurementUsers ManualBacklightPress C to toggle the backlight on and off. The backlight automatically turns off after 2 minutes.To disable the automatic 2-minute backlight timeout, hold down C while turning the Meter on.MIN MAX Recording ModeThe MIN MAX recording mode captures the minimum and maximum input values. When a new high or low is detected, the Meter beeps.To use this feature:1.Put the Meter into the desired measurement functionand range.2.Press J to enter MIN MAX Mode. MAX is displayedand the highest reading detected since entering MINMAX is displayed.3.Press J to step through the minimum (MIN) andpresent readings.4.To pause MIN MAX recording without erasing storedvalues, press I. K is displayed.5.To resume MIN MAX recording, press I again.6.To exit and erase stored readings, press J for atleast two seconds.Using the MeterDisplay HOLDXW WarningTo avoid possible electric shock or personalinjury, when Display HOLD is activated, beaware that the display will not change whenyou apply a different voltage.In the Display HOLD mode, the Meter freezes the display. The Meter also beeps every 4 seconds and H flashes to remind the user.Press I to activate Display HOLD; H is displayed and the reading is captured.To exit and return to normal operation, press I.Auto OffThe Meter automatically turns off after 20 minutes. The rotary switch must be turned to “OFF” and then turned back on for the Meter to restart. Auto Off is disabled during Min Max mode. To disable Auto Off, hold J when turning the Meter on.Users ManualMaintenanceXW WarningTo avoid possible electric shock or personalinjury, repairs or servicing not covered in thismanual should be performed only by qualifiedpersonnel.Cleaning the MeterXW WarningTo avoid electrical shock, remove any inputsignals before cleaning.W CautionTo avoid damaging the Meter, do not usearomatic hydrocarbons or chlorinated solvents for cleaning. These solutions will react with the plastics used in the Meter.Clean the instrument case with a damp cloth and mild detergent.MaintenanceBattery ReplacementXW WarningTo avoid false readings that could lead topossible electric shock or personal injury,replace the batteries as soon as the lowbattery indicator (B) appears.Disconnect the test leads before replacing thebatteries.To replace the batteries (refer to Figure 6):1.Turn the rotary switch to “OFF” and remove the testleads from the terminals.e a Phillips screwdriver to loosen the batterycompartment door screw, and remove the door fromthe case bottom.3.Remove the batteries.4.Replace the batteries with two new AA batteries.5.Reattach the battery compartment door to the casebottom and tighten the screw.Users ManualFigure 6. Battery ReplacementSpecifications SpecificationsElectrical SpecificationsFunction Range Resolution Accuracy Voltage DC 0 – 600 V 0.1 V 1 % ± 5 countsVoltage AC (True Rms) 0 – 600 V 0.1 V1 % ± 5 counts(50/60 Hz)Current AC (True Rms) 0 – 600 A 0.1 A2.0 % ± 5 counts(50/60 Hz)Current DC 0 - 200 µA 0.1µA 1.0 % ± 5 countsResistance 0 – 999 Ω0 – 9999 Ω0.1 Ω1.0 Ω1.5 % ± 5 countsContinuity <30ΩTemperature -10 to 400 °C 0.1 °C 1 % ± 0.8 °CCapacitance 1-100 µF100-1000 µF0.1 µF1 µF1.9 % ± 2 countsUsers ManualGeneral SpecificationsOperating Temperature -10 °C to +50 °CStorage Temperature -40 °C to +60 °COperating Humidity Non condensing (< 10 °C)90 % RH (10 °C to 30 °C)75 % RH (30 °C to 40 °C)45 % RH (40 °C to 50 °C)(Without Condensation) Operating Altitude 2500 meters above mean sealevelStorage Altitude 12,000 meters above meansea levelIP Rating IP 30 per IEC 60529 Vibration Requirements MIL-PRF-28800F Class 2random vibrationEMI, RFI, EMC EMI: instrument unspecified foruse in EMC field • 0.5 V /MeterEMC: Meets all applicablerequirements in EN61326-1Temperature Coefficients 0.1 x (specified accuracy)/ °C (<18 °C or >28 °C)HVAC Clamp Meter Specifications25Size (H X W X L) 9.1 x 3.8 x 1.7 inches (240 x 80 x 40 mm) Weight1.1 lb (310 g)Design Standards and Compliance IEC 61010, IEC 61010-2-032,CEAgency ApprovalsP ) ; sN10140Over-voltage Category600 V, CAT III per IEC 1010-1CAT III equipment is designed to protect against transients in equipment in fixed-equipment installations, such asdistribution panels, feeders and short branch circuits, and lighting systems in large buildings.Power Requirements Two AA Batteries , NEDA 15 A, IEC LR61.888.610.7664**************************Fluke -Direct .com902Users Manual26**************************1.888.610.7664。
Mellanox QSFP+ 直接附接铜线(DAC)线缆商品介绍说明书
Mellanox ® QSFP+ direct attach copper (DAC) cables provide robust connections for leading edge 56Gb/s InfiniBand or 40GbE Ethernet systems. The cables consist of four lanes each operating at data rates of up to 14.0625Gb/s.Passive copper cables require no additional power to ensure quality connectivity. The cables are compliant with SFF-8685 specifications and provide connectivity between devices using QSFP+ ports. Each QSFP+ port comprises an EEPROM providing product information, which can be read by the host system.This integrated cable solution provides reliable transport for aggregate data rates of up to 56Gb/s Virtual Protocol Interconnect (VPI). Optimizing systems to operate with Mellanox’s 56Gb/s passive copper cables significantly reduces power consumption and EMI emission, eliminating the use of enterprise data center (EDC) hosts.Mellanox’s unique quality passive copper cable solutions provide power-efficient connectivity for short distance interconnects. They enable higher port bandwidth, density and configurability at a low cost and reduced power requirement in the data centers.Rigorous cable production testing ensures best out-of-the-box installation experience, performance and durability.Table 1 - Absolute Maximum RatingsTable 2 - Operational Specifications56Gb/s and 40GbE QSFP + Direct Attach Copper CablesINTERCONNECT PRODUCT BRIEFMC22061xx-00x | MC22071xx-0xx | MC22101xx-00x | MCP170L-F0xx | MCP1700-B0xxx†T able 3 - Electrical SpecificationsT able 4 - Cable Mechanical SpecificationsNote 1. See Figure 1 for the cable length definition.Note 2: *The pulltab color is black, instead of the standard blue pulltab.Note 3: The minimum bending space is the distance from the system panel to the edge of the cable bend with the minimum assembly bending radius. This corresponds to the distance from the switch panel to the rack door.Note 4: The minimum assembly bending radius (close to the connector) is 10x the cable’s outer diameter. The repeated bend (far from the connector) is also 10x the cable’s outer diameter. The single bend (far from the connector) is 5x the cable’s outer diameter.Figure 1. Cable Length DefinitionMechanical Schematics350 Oakmead Parkway, Suite 100, Sunnyvale, CA 94085Tel: 408-970-3400 • Fax: © Copyright 2018. Mellanox Technologies. All rights reserved.Mellanox, Mellanox logo and LinkX are registered trademarks of Mellanox Technologies, Ltd. Warranty InformationMellanox LinkX direct attach copper cables include a 1 year limited hardware warranty, which covers parts repair or replacement.Table 5 - Part Numbers and DescriptionsNote: The standard pulltab color is blue; cables with a black pulltab are indicated accordingly.。
Hoffman Enclosures Inc. 电子变压器操作适配器(适用于Eaton Cutle
89115496
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 • /HOFFMAN
-3-
For Floor-Mounted, Two-Door Enclosures with Disconnect on Right Flange
0DVWHU 'RRU
)RURQHWKURXJKVL[GRRUIUHHVWDQGLQJHQFORVXUHV ZLWKWKHGLVFRQQHFWWKHWKHULJKWIODQJH 0DVWHU 'RRU
)RUIORRUPRXQWHGHQFORVXUHVZLWK WKHGLVFRQQHFWRQWKHFHQWHUSRVW
Step 5 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted (see step 6B)
Item No. Description
Part No.
Qty.
1
MOUNTING PLATE, C-H C361 AND C371
26385001
1
2
GASKET, PLATE
89109613
1
3
SCREW, 1/4-20X1/2 PAN HEAD
99401031
4
4
美琴263585产品说明书
Eaton 263585Eaton Moeller series xPole - PF6/7 RCCB. PF7, 4 pole, In: 25 A, Icn: 10 kA, I ΔN: 0.1 A, Type AC, AC current sensitive, Partly surge-proof 250 A, residential and commercialGeneral specificationsEaton Moeller series xPole - PF6/7 RCCB263585PF7-25/4/01-DE401508263585580 mm 71 mm 70 mm 0.32 kg RoHS conformIEC/EN 61008Product NameCatalog Number Model Code EANProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications25 AIs the panel builder's responsibility. The specifications for the switchgear must be observed.7035-35 °CMeets the product standard's requirements.Is the panel builder's responsibility. The specifications for the switchgear must be observed.DIN railQuick attachment with 2 latch positions for DIN-rail IEC/EN 6071525 ADoes not apply, since the entire switchgear needs to be evaluated.0.1 A184 V AC - 440 V ACMeets the product standard's requirements.Non-delayedIS/SPE-1TE 101911Interlocking device500 A eaton-rcd-application-guide-br019003en-en-us.pdfeaton-xpole-pf7-rccb-catalog-ca019032en-en-us.pdf eaton-xpole-pf6-rccb-catalog-ca019034en-en-us.pdfDA-DC-03_PF7eaton-circuit-breaker-xeffect-frcmm-rccb-dimensions.jpg eaton-xpole-pf6/7-rccb-3d-drawing.jpgIL019140ZUeaton-xeffect-frcmm-rccb-wiring-diagram-002.jpgRated operational current for specified heat dissipation (In) 10.11 Short-circuit ratingRAL-numberPermitted storage and transport temperature - min10.4 Clearances and creepage distances10.12 Electromagnetic compatibilityMounting MethodAmperage Rating10.2.5 LiftingRated fault current - maxTest circuit range10.2.3.1 Verification of thermal stability of enclosures Tripping timeFitted with:Rated residual making and breaking capacity Application notes Catalogs Certification reports DrawingsInstallation instructions Wiring diagramsFrequency rating50 Hz10.8 Connections for external conductorsIs the panel builder's responsibility.Fault current rating100 mATerminal protectionFinger and hand touch safe, DGUV VS3, EN 50274Special featuresMaximum operatingtemperature is 55 °C:Starting at 40 °C, the max.permissible continuouscurrent decreases by 3% forevery 1 °CTripping signal contact forsubsequent installation Z-NHK 248434Sensitivity typeAC current sensitiveAmbient operating temperature - max55 °CHeat dissipation per pole, current-dependent0 WClimatic proofing25-55 °C / 90-95% relative humidity according to IEC 60068-2Built-in depth69.5 mmShort-circuit rating63 A (max. admissible back-up fuse)FeaturesResidual current circuit breakerAdditional equipment possibleLifespan, electrical4000 operationsConnectable conductor cross section (solid-core) - min1.5 mm²10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Number of polesFour-poleTerminal capacity (solid wire)1.5 mm² - 35 mm²Ambient operating temperature - min-25 °C10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.Rated short-circuit strength10 kA10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Used withKLV-TC-4 276241 (Compact enclosure) Z-FW/LP 248296 (Remote control and automatic switching device) Z-RC/AK-4TE 101062 (sealing cover set)Residual current circuit breakersPF7Type ACKLV-TC-4 276241 (Compact enclosure)Z-FW/LP 248296 (Remote control and automatic switching device)Z-RC/AK-4TE 101062 (sealing cover set)Equipment heat dissipation, current-dependent2.8 W10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Static heat dissipation, non-current-dependent0 WApplicationResidual current circuitbreaker for residential andcommercial applicationsxPole - Switchgear forresidential and commercialapplications10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Voltage typeACTerminal capacity (stranded cable)16 mm² (2x)Leakage current typeACFrame45 mmBuilt-in width (number of units)70 mm (4 SU)Terminals (top and bottom)Open mouthed/lift terminalsHeat dissipation capacity0 WImpulse withstand currentPartly surge-proof 250 AWidth in number of modular spacings4Busbar material thickness0.8 mm - 2 mm10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Lifespan, mechanical20000 operationsVoltage rating230 V AC / 400 V AC10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Connectable conductor cross section (solid-core) - max35 mm²Degree of protectionIP20, IP40 with suitable enclosureIP20Rated short-time withstand current (Icw)10 kAAccessories requiredZ-HK 248432Pollution degree210.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Connectable conductor cross section (multi-wired) - min 1.5 mm²Rated impulse withstand voltage (Uimp)4 kV10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Connectable conductor cross section (multi-wired) - max 16 mm²TypePF7Residual current circuitbreakersType AC10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Surge current capacity0.25 kAPermitted storage and transport temperature - maxEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia60 °C25 A gG/gL0.1 A400 V440 VAdmissible back-up fuse overload - max Rated fault current - min Rated operational voltage (Ue) - max Rated insulation voltage (Ui)。
3386电位器
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex. Fluorinert is a registered trademark of 3M Co.Specifications are subject to change without notice.Customers should verify actual device performance in their specific applications.ModelStyleStandard or Modified Product Indicator-1 = Standard Product -EY5 = Extended Shaft Resistance Code Optional Suffix LetterT =Knob**Packaging DesignatorBlank =Tube (Standard)R =T ape & Reel (W and U Pin Styles Only)A =Ammo Pack (W and U Pin Styles Only)TerminationsLF =100 % Tin-plated (RoHS compliant)Blank =90 % Tin / 10 % Lead-plated(Standard)**Knob option is available only in standard Tube packaging.Consult factory for other available options.Electrical Characteristics Standard Resistance Range..................................10 to 2 megohms(see standard resistance table)Resistance Tolerance............±10 % std.(tighter tolerance available)Absolute Minimum Resistance.........................................2 ohms max.Contact Resistance Variation.............................2 % or 3 ohms max.(whichever is greater)AdjustabilityVoltage....................................±0.05 %Resistance..............................±0.15 %Resolution.....................................Infinite Insulation Resistance................500 vdc.1,000 megohms min.Dielectric StrengthSea Level .................................900 vac 70,000 Feet..............................350 vac Adjustment Angle..................280 °nom.Environmental Characteristics Power Rating (300 volts max.)85 °C........................................0.5 watt 125 °C.........................................0 watt Temperature Range....-55 °C to +125 °C Temperature Coefficient....±100 ppm/°C Seal Test........................85 °C Fluorinert †-STD-202 Method 10396 hours(2 % ∆TR, 10 Megohms min.)Vibration.........30 G (1 % ∆TR; 1 % ∆VR)Shock...........100 G (1 % ∆TR; 1 % ∆VR)Load Life ..1,000 hours 0.5 watt @ 70 °C(3 % ∆TR; 1 % or 1 ohm,whichever is greater, CRV)Rotational Life........................200 cycles(4 % ∆TR; 1 % or 1 ohm,whichever is greater, CRV)Physical CharacteristicsMechanical Angle..................310 °nom.Torque .............................5.0 oz-in. max.Stop Strength................15.0 oz -in. min.Terminals........................Solderable pins Weight ........................................0.03 oz.Marking...........................Manufacturer’strademark, resistance code,wiring diagram, date code,manufacturer’s modelnumber and styleFlammability...........................U.L. 94V-0Standard Packaging.....50 pcs. per tube Wiper................50 % (Actual TR) ±10 %Adjustment Tool..............................H-90.76(.030) .76(.030)3.15(.124)X X Resistance Resistance (Ohms)Code 1010020200505001001012002015005011,0001022,0002025,00050210,00010320,00020325,00025350,000503100,000104200,000204250,000254500,0005041,000,0001052,000,000205Standard Resistance TablePopular distribution resistance values listed in boldface. Special resistances available.*Ro H S C O M P L I A N T V E R S I O N S A V A I L A B L ESpecifications are subject to change without notice.Customers should verify actual device performance in their specific applications.The Model 3386 is available with a knob for finger adjustment. Add suffix letter "T" to order code for F , P and X terminal styles.ADJ. SLOT 5.59(.220) 1.02(.040) 1.40(.055) WIDE DEEPLONG ADJ. SLOT 3386H-EY53386X-EY5 – SHOWNCLOCKWISEDIMENSIONS ARE:MM (INCHES)TOLERANCES: ±0.25 (.010) EXCEPT WHERE NOTEDSpecifications are subject to change without notice.Customers should verify actual device performance in their specific applications.REV. 02/06SIDE ADJUST 3386W-1TOP ADJUST 3386U-1Packaging SpecificationsMeets EIA Specification 468.。
美迪辛士化学产品清单表说明书
1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Medisanitize Universal Wipes1.2 Relevant identified uses of the substance or mixture and uses advised againstUses:Disinfection of hands and hard surfaces 1.3 Details of the supplier of the Safety Data SheetCompany name Extergeo industries ltdAddress B5 Buckshaw linkBuckshaw villageChorleyPR7 7ELUKTelephone +44(0)1772347771EmailWebsite 1.4 Emergency Telephone Number 017723477712: Hazards identification2.1 Classification of the substance or mixture2.1.1Regulation (EC) No 1272/2008(CLP)Mixture not classified as hazardous2.2 Label elements2.2.1 Label elements Contains PHMB. May produce an allergic reaction.GHS Product Identifier Medisanitize Universal WipesSignal word(s) WarningPrecautionary statement Prevention P102 - Keep out of reach of children. P103 - Read label before use.Precautionary statement: Response P101 - If medical advice is needed, have product container or label at hand.P301+P330+P331: IF SWALLOWED: Rinse mouth.P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.2.3Other hazards Not classified as PBT or vPvB.3: Composition/Information on ingredients3.1 Substances4: First-aid measures4.1Description of first aidInhalationmeasures Move affected person to fresh air at once. When breathing is difficult, properly trained personnel may assist affected person by administering oxygen. Get medical attention.Eye contact Rinse immediately with plenty of water. Remove any contact lenses and openeyelids wide apart. Continue to rinse for at least 15 minutes. Get medical attention if any discomfort continues.Skin contact Remove contaminated clothing immediately and wash skin with soap andwater. Get medical attention if any discomfort continues. Wash contaminated clothing before reuse.IngestionMove affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Rinse mouth thoroughly with water. Give plenty of water to drink. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention immediately.4.2Most important symptoms and effects, both acute and delayed May cause irritation.5.1 Extinguishing media Suitable extinguishing media for the surrounding fire should be used.5.2Special hazards arising from the substance or mixtureCorrosive. In combustion emits toxic fumes.5.3 Advice for firefighters Standard protective equipment should be worn by fire fighters, inparticular eye / face protection.6: Accidental release measures6.1 Personal precautions, Large spillages are highly unlikely due to pre-saturation of liquid on protectiveequipment and fabric substrate. emergency procedures6.2 Environmental precautions Do not allow product to enter drains. Do not flush into surface water.6.3 Methods and material for Transfer to suitable, labelled containers for disposal. Clean spillagecontainment and cleaning up area thoroughly with plenty of water.6.4 Reference to other sections For recommended personal protective equipment see Section 8. For disposal see Section 13.7: Handling and storage7.1 Precautions for safe handling Avoid contact with eyes. Adopt best Manual Handling considerationswhen handling, carrying and dispensing.7.2 Conditions for safe storage,including any incompatibilities Keep out of the reach of children. Keep in a cool, dry, well ventilated area. Keep containers tightly closed.7.3 Specific end use No relevant information available.8: Exposure controls/personal protection8.1 Control parametersExposure controls No data availableExposure Limit Values No data available8.2 Engineering controlsRespiratory protection Keep in a cool, dry, well ventilated area.Individual protection measures None normally requiredEnvironmental exposure controls None normally required9: Physical and chemical properties9.1 Information on basic physical and chemical propertiesAppearance White nonwoven fabric pre-saturated with a colourlesssolutionOdour SpearmintpH No information available10: Stability and reactivity10.1 Reactivity Stable under normal conditions of storage/use.10.2 Chemical Stability Stable under recommended storage and handling conditions.10.3 Possibility of hazardousNone expectedreactions10.4 Conditions to avoid Avoid excessive heat. Do not allow to freeze.10.5 Incompatible materials Strong acids and Strong bases. Strong oxidising agents.In combustion emits toxic fumes10.6 Hazardous decompositionproducts11: Toxicological informationNo data available for this product12: Ecological informationNo data available for this product13: Disposal considerations13.1 Waste treatment Dispose of as special waste in compliance with local and national regulations.methods Empty containers can be sent to landfill after cleaning, if in compliance with local and national regulations.14: Transport informationThis preparation is not classified as “Hazardous” for transport purposes15: Regulatory information15.1 Safety, health and environmental regulations / legislation specific for the substance or mixture Notapplicable.Chemical Safety Assessment15.2 A chemical safety assessment has not been carried out for the substance or the mixture by the supplier.16: Other informationRevision information:Reviewed – no changesList of Abbreviations used in this SDS:CAS Chemical Abstracts ServiceCLP Classification, Labelling and Packaging Regulation (EC) no 1272/2008EC European Community/CommissionPBT Persistent, Bioaccumulative and ToxicREACH Registration, Evaluation, Authorisation and Restriction of Chemicals Regulation(EC) no 1907/2006vPvB very Persistent, very BioaccumulativeReferencesCLP Regulation 1272/2008ECHA Chem database of registered substancesSuppliers’ SDSR Phrases and H Statements used in Section 3Acute Tox. 4: H312 - Harmful in contact with skinAcute Tox. 4: H302 - Harmful if swallowed.Skin Corr. 1B: H314 - Causes severe skin burns and eye damage.Aquatic Acute 1: H400 - Harmful to aquatic lifeAquatic Chronic 2: H411 - Toxic to aquatic life with long lasting effects Carc.2: H351 - Suspected of causing cancer.Acute Tox. 2: H330 - Fatal if inhaled.STOT RE 1: H372 - Causes damage to organs through prolonged or repeated exposure.Eye Dam. 1: H318 - Causes serious eye damage.Skin Sens. 1B: H317 - May cause an allergic skin reaction.Aquatic Chronic 1: H410 - Very toxic to aquatic life with long lasting effectsTraining requirements for workersNo specific training required for workersThis Safety Data Sheet contains information concerning the potential risks to those involved in handling, transporting, and working with the material, as well as describing potential risks to the consumer and the environment. This information is based on our present state of knowledge and is intended to describe our products from the point of view of the safety requirements. It should not be construed as guaranteeing specific properties. This Safety Data Sheet is prepared in accordance with formatting described in the REACH Regulation (EC) No 1907/2006 and described in CLP Regulation (EC) No 1272/2008.。
三氟乙酸 安全技术说明书
三氟乙酸安全技术说明书页码 1 / 9生效日期 21-Sep-2009修订日期 11-Jun-2019版本 2ALFAAL06374根据G B /T 16483-2008, G B /T 17519-2013一 化学品及企业标识产品描述:三氟乙酸Product Description:Trifluoroacetic acid目录编号L06374同义字TFA; Trifluoroethanoic acid; Perfluoroacetic acid 化学文摘编号(C A S N o .)76-05-1分子式C2 H F3 O2供应者紧急电话号码电子邮件地址推荐用途实验室化学品.不建议的用途无资料。
二 危险性概述物质或混合物的分类急性吸入毒性 - 蒸气类别4皮肤腐蚀/刺激类别1 A 严重眼损伤 / 眼刺激类别1慢性水生毒性类别3标签元素应急综述造成严重皮肤灼伤和眼损伤. 对水生生物有害并具有长期持续影响. 可能腐蚀金属. 吸入有害. 吸湿的.对金属具有腐蚀性的物质/混合物类别1物理状态液体外观透明的, 无色气味辛辣的上海齐奥化工科技有限公司上海浦东新区环科路515号1号楼910室紧急电话号码+8621-50396381传真:+8621-50396382+86 21-50940938邮件地址:产品安全部门。
警示语危险危害声明H290-可能腐蚀金属H314-造成严重皮肤灼伤和眼损伤H412-对水生生物有害并具有长期持续影响H332-吸入有害防范说明预防P234-只能在原容器中存放P264-作业后彻底清洗脸部、手部和任何接触的皮肤P271-只能在室外或通风良好之处使用P280-戴防护手套/穿防护服/戴防护眼罩/戴防护面具。
响应P301+P330+P331-若不慎吞食:漱口。
不要引吐P303+P361+P353-如皮肤(或头发)沾染:立即脱掉所有沾染的衣服。
用水清洗皮肤/淋浴P304+P340-如果吸入:将患者移到新鲜空气处休息,并保持呼吸舒畅的姿势。
卡洛加吉电子有限公司产品:无线困扰保护设备说明书
Product DescriptionWireless Entrapment Pro-tection Device (EPD) for Industrial Gates. The system is designed to replace the connection cable between the ESPE (electro-sensitive protective equipment) and the gate controller. The sub-controller has input for either N.C. ESPE, N.O. 8.2 kΩ ESPE or the Carlo Gavazzi low con-sumption photoelectric ESPE N.C. contact. The system is designed for high reliabilityusing 2.4 GHz duplex com-munication between the main controller and sub controller. The main controller can han-dle up to 6 sub controllers i.e. one system can handle 12 ESPEs.The active time is initiated with a test signal applied on the main controller. The dura-tion of this can be fixed or defined by the length of the test signal.• Wireless Entrapment Protection Device for Industrial Gates• Input for two ESPE (electro-sensitive protective equipment)• Replaces cable between Gate controller and ESPE • Output ESPE: 2 x SPST NC or 2 x SPST NO (8,2kΩ) or 2 x Photoelectric sensors• Output low battery: 1 x SPST NC or NO • 2,4 GHz duplex communication • Built-in antenna • IP66 ratingsWireless Entrapment Protection Device For Industial Gates ESPEType WSM / WSS …Specifications Main Controller (WSM)Type SelectionHousing Range Output Type Ordering no.W x H x D Wireless75 x 125 x 35 mm 15 m NO 8K2 Main Controller WSM6GAOOD2475 x 125 x 35 mm 15 m NC Main Controller WSM6GACCD2445 x 214 x 22 mm 15 m-Sub Controller WSS2GA2BAT Housing Range Cable length TypeOrdering no. W x H x D S n Photoelectric Sensor Ø11 x 24.5 mm 2.5 m 2 m Emitter PB 11 CNT 15 WE Ø11 x 24.5 mm2.5 m12 mReceiverPB 11 CNT 15 WRICWSM/WSS ...Specifications Main Controller (WSM) (cont.)Specifications Sub Controller (WSS)NOTE: Changes/modifications not approved by Carlo Gavazzi could void the user’s authority to operate the equipment.WSM/WSS ...Specifications Photoelectric Sensors ESPE (PB11)NOTE: Changes/modifications not approved by Carlo Gavazzi could void the user’s authority to operate the equipment.Specifications Sub Controller (WSS) (cont.)(R&TTE) Directive 1999/5/EC Low Voltage Directive 2006/95/ECElectromagnetic Compatibility Directive 2004/108/EC Machinery Directive 2006/42/EC, amended by Directive 98/79/ECFor industrial doors onlySee EN13241-1Operation Diagram: Fixed Active TimeWSM/WSS ...Excess Gain PB111101001000E x c e s s g a i n110Distance (m)1003,332,8328,1(feet)Operation Diagram: Manual Active TimeWSM/WSS ...Detection Diagram PB11-60-40-202040600246810126,613,119,726,332,839,4Sensing range (m)(m )0(Feet)-196,9-131,2-65,665,6131,2196,90(F e e t )Wiring DiagramsYXEmitterReceiverLifetime of batteriesActive Duration in seconds3 Sub ctrl., 2 x optical sensors12 Cycles/day 25 Cycles/day 50 Cycles/day 100 Cycles/day 200 Cycles/day 400 Cycles/dayY e a r s0,00,40,20,60,81,01,21,41,61530604575901050,00,40,20,60,81,01,21,41530604575901053 Sub ctrl., 2 x Mech NO-8K2Active Duration in secondsY e a r sActive Duration in seconds 1 Sub ctrl., 2 x optical sensors12 Cycles/day 25 Cycles/day 50 Cycles/day 100 Cycles/day 200 Cycles/day 400 Cycles/dayY e a r s0,00,40,20,60,81,01,21,61,41530604575901050,00,40,20,60,81,01,21,41530604575901051 Sub ctrl.,2 x Mech. NO-8K2Active Duration in secondsY e a r sConditions: 240 working days, ambient temperature 20°C, 85% battery efficiency. ”Duration” is gate opening or closing time. One cycle is an opening AND closing cycle.4 x ER14505 3.6 VDC size AA, ≥ 2700 mAh Lithium batteriesNormal speedFast speedWSM/WSS ...WSM/WSS ... DimensionsDelivery Contents Main Controller •Wireless Main Controller: WSM6GAOOD24 orWSM6GACCD24• Manual•4 x SCREW M4.5X45 MM BOSSARD BN615•4 x RAWLPLUG SX8 NYLON• Packaging: Cardboard box Delivery Contents Sub Controller •Wireless Sub Controller: WSS2GA2BAT• Manual•2 x ER14505 3.6 VDC size AA, ≥ 2700 mAh Lithium batteries•4 x SCREW M4X10 MM BOSSARD BN1023• Packaging: Cardboard boxDelivery Contents Receiver •Receiver: PB11CNT15WR• Packaging: Plastic bag Delivery Contents Emitter •Emitter: PB11CNT15WE• Packaging: Plastic bag。
TEDA-L33E商品说明书
SAFETY DATA SHEET: TEDA – L33E – US-GHS VersionTEDA - L33E1. IDENTIFICATION OF THE SUBSTANCE OR MIXTURE AND OF THE SUPPLIERPRODUCT IDENTIFIER: TEDA – L33EMANUFACTURER / IMPORTER:TOSOH SPECIALTY CHEMICALS USA, Inc. ADDRESS: 1720 Windward Concourse, Suite 125Alpharetta, Georgia 30005 PHONE: 1-770-442-9501EMERGENCY PHONE :CHEMTREC 1-800-424-9300 OR 1-703-527-3887RECOMMENDED USE:General industrial products2. HAZARDS IDENTIFICATIONGHS CLASSIFICATIONAcute toxicityOral: Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Specific target organ toxicity – single exposure Category 3 Specific target organ toxicity – repeat exposure Category 2HAZARD SYMBOL:SIGNAL WORD : WARNINGHAZARD STATEMENTS :Harmful if swallowed. Causes skin irritation.Causes serious eye irritation.May cause drowsiness or dizziness.May cause damage to kidneys through prolonged or repeated exposure.PREVENTION :Wash thoroughly after handling.Do not eat, drink or smoke when using thisproduct.Wear protective gloves/eye protection/faceprotection.Avoid breathingdust/fume/gas/mist/vapors/spray.Use only outdoors or in a well-ventilated area.distributed by:Request Quote or SamplesSAFETY DATA SHEET: TEDA – L33E – US-GHS Version2. HAZARDS IDENTIFICATION (continued)RESPONSE :If in eyes: Rinse cautiously with water for several minutes.Remove contact lenses, if present and easy to do.Continue rinsing.If eye irritation persists: Get medical advice/attention.If on skin (or hair): Wash with plenty of water. If skin irritation occurs: Get medical advice/attention.Take off contaminated clothing and wash it before reuse.If inhaled: Remove person to fresh air and keep comfortable for breathing.Call a poison control center/doctor if you feel unwell.If swallowed: Rinse mouth.Call a poison control center/doctor if you feel unwell.STORAGE: Store in a well-ventilated place. Keep container tightly closed.Store locked up.DISPOSAL :Dispose of contents/container in accordance with Federal and state regulations.3. COMPOSITION/INFORMATION ON INGREDIENTSOSHAChemical Name CAS # Hazardous(Y/N) Concentration (%) Triethylenediamine 280-57-9 Y 33 Ethylene glycol 107-21-1 Y 674. FIRST AID MEASURESEYE CONTACT:Hold eyelids open and flush with a steady, gentle stream of water for at least 15 minutes. Seek medical attention if eye irritation develops or persists.SKIN CONTACT:Remove contaminated clothing and shoes. Wash with plenty of water, for at least 15minutes. Seek medical attention if skin irritation develops or persists. Launder contaminated clothing and shoes before re-use.SAFETY DATA SHEET: TEDA – L33E – US-GHS Version4. FIRST AID MEASURES (continued)INGESTION:Do not induce vomiting. If victim is conscious and alert, give 1-2 glasses of water to drink. Do not give anything by mouth to an unconscious person. Seek immediate medical attention. Do not leave victim unattended.INHALATION:If respiratory irritation or distress occurs, remove victim to fresh air. Seek imedical attention if respiratory irritation or drowsiness develops or persists.NOTES TO PHYSICIAN :All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred. Treatsymptomatically. No specific antidote available.5. FIRE FIGHTING MEASURESEXTINGUISHING MEDIA: Water spray, fog, dry chemical, foam, CO 2UNUSUAL FIRE AND EXPLOSION HAZARDS:Closed containers may rupture due to buildup of pressure when exposed to extreme heat. SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTERS:Firefighters should wear NIOSH/MSHA-approved self-contained breathing apparatus and full protective clothing. Cool containers exposed to fire with water.HAZARDOUS DECOMPOSITIONMATERIALS UNDER FIRE CONDITIONS : Oxides of carbon, oxides of nitrogen, ammonia.6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS: Wear appropriate protective gear for thesituation. (See Personal Protection Information in Section 8).ENVIROMENTAL PRECAUTIONS :Do not flush to drain. Spills may be reportable to the National Response Center (800-424-8802) and to state and/or local agencies.METHOD FOR CLEAN UP:Extinguish or remove all sources of ignition. Absorb with an inert absorbent, sweep up and place in an appropriate closed container. Clean up residual material by washing area with water. Collect washings for disposal. Spills may be reportable to the National Response Center (800-424-8802) and to state and/or local agencies.SAFETY DATA SHEET: TEDA – L33E – US-GHS Version7. HANDLING AND STORAGEPRECAUTIONS FOR SAFE HANDLING : Handle material with suitable protection (SeeSection 8). Handle with adequate ventilation. Avoid breathing vapors. Avoid contact with eyes, skin and clothing.VENTILATION:General area dilution/exhaust ventilation.CONDITIONS FOR SAFE STORAGE :Store upright in a cool, dry, well ventilated area out of direct sunlight. Keep away from heat,open flames and ignition sources. Keep container tightly closed. Do not reuse container.8. EXPOSURE CONTROLS/PERSONAL PROTECTIONENGINEERING MEASURES:Set up hand-wash station and eyewash station near work area.General area dilution/exhaust ventilation.EXPOSURE LIMITS:Ethylene glycol – 100 mg/M 3 - ACGIH ceilingPERSONAL PROTECTION MEASURES:Respiratory protection :When respirators are required, selectNIOSH/MSHA approved equipment based on actual or potential airborne concentrations and in accordance with regulatory standards and/or industrial recommendations. Self-contained or supplied-air respiratory equipmment is recommended.Eye protection : Safety glasses with side shields, goggles or face shield are recommended.Skin protection :Skin contact should be minimized through the use of chemical-resistant gloves and boots, and suitable protective clothing.The following general measures should be taken when working or handling this material:1) Do not store, use, and/or consume foods, beverages, tobacco products, or cosmetics in areas where this material is stored.2) Wash hands and face carefully before eating, drinking, using tobacco, applying cosmetics, or using the toilet.3) Wash exposed skin promptly to remove accidental splashes of contact with this material.9. PHYSICAL AND CHEMICAL PROPERTIESPHYSICAL STATE: Liquid COLOR: Pale yellow ODOR: Ammonia-like pH: 11.0 (@10% aqueous) MELTING POINT: No data availableSAFETY DATA SHEET: TEDA – L33E – US-GHS Version9. PHYSICAL AND CHEMICAL PROPERTIES (continued)BOILING POINT: 363-385F (184-196C) FLASH POINT: 219F (104C) AUTOIGNITION POINT: 608F (320C) EXPLOSIVE LIMITS(Lower): No data available EXPLOSIVE LIMITS(Upper): No data available VAPOR PRESSURE: < 13 Pa @ 20C (68F) VAPOR DENSITY: 2.52 (Air = 1) EVAPORATION RATE: No data available RELATIVE DENSITY: 1.10 SOLUBILITY IN WATER : Soluble PARTITION COEFFICIENT: No data available DECOMPOSITION TEMPERATURE: No data available10. STABILITY AND REACTIVITYCHEMICAL STABILITY:This material is stable under normal handlingand storage conditions described in Section 7.CONDITIONS TO AVOID: Heat, open flame, sparks, direct sunlight.INCOMPATIBLE MATERIALS:Strong oxidizing agents, strong acids, copper, zinc, aluminum and their alloys.HAZARDOUS DECOMPOSITION PRODUCTS: Oxides of carbon, oxides of nitrogen, ammonia.HAZARDOUS POLYMERIZATION: Not applicable11. TOXICOLOGICAL INFORMATIONEYE CORROSION/IRRITATION: Severely irritating, rabbit. (Data for Triethylenediamine)SKIN CORROSION/IRRITATION: Moderately irritating, rabbit. (Data for Triethylenediamine)ACUTE TOXICITY:ACUTE ORAL TOXICITY: LD 50 = 1700 mg/kg, rat. (Data for Triethylenediamine)ACUTE DERMAL TOXICITY : LD 50 > 2000 mg/kg, rat. (Data for Triethylenediamine)ACUTE INHALATION TOXICITY :LC 50 ≥ 20.2 mg/L/1 hour, rat (tested as a 20% solution). (Data for Triethylenediamine)SKIN SENSITIZATIONNot a sensitizer (guinea pig). (Data for Triethylenediamine)GENETIC TOXICITYNot mutagenic in the Ames test or in vivo mouse micronucleus test. (Data for Triethylenediamine)SAFETY DATA SHEET: TEDA – L33E – US-GHS Version11. TOXICOLOGICAL INFORMATION (continued)CARCINOGENICITY:This product does not contain any substances that are considered by OSHA, NTP, IARC or ACGIH to be “probable” or “suspected” human carcinogens.REPRODUCTIVE TOXICITY:In a combined repeat-dose/reproductive study (OECD 422) with Triethylenediamine, theNOAEL (no-observed-adverse-effect level) for F0 reproductive toxicity was considered to be 300 mg/kg/day. The NOAEL for Fl neonatal toxicity was considered to be 300 mg/kg/day. The NOAEL for F0 parental systemic toxicity was considered to be 100 mg/kg/day.Reproductive studies with ethylene glycol show that in repeated dose toxicity studies, noevidence of an adverse impact on reproductive organs was observed. In special studies, including a three generation study in rats and continuous breeding protocols in mice, evidence of reproductive effects have been restricted to mice (but not rabbits or rats) exposed to doses considerably higher than those associated with developmental effects in this species or renal effects in rats.STOT-SINGLE EXPOSURE : Ethylene glycol may cause central nervous system depression and drowsiness.STOT-REPEATED EXPOSURE:In a combined repeat-dose/reproductive study (OECD 422) with Triethylenediamine, reversible, treatment-related effects wereobserved in the kidneys and bladders of mid-to-high dose animals. The NOAEL for ethylene glycol was determined to be 150 mg/kg/day and appears to be a threshold dose below which no renal toxicity occurs.12. ECOLOGICAL INFORMATIONECOTOXICITY:96hr LC 50 > 100 mg/L (carp)48hr EC 50 > 92 mg/L (daphnia magna)72hr EC 50 > 110 mg/L (algae, biomass), > 180mg/L (algae, growth rate) (All data for Triethylenediamine)PERSISTENCE AND DEGRADABILITY: Not readily biodegradable (Data forTriethylenediamine)MOBILITY IN SOIL:No data availableSAFETY DATA SHEET: TEDA – L33E – US-GHS Version13. DISPOSAL CONSIDERATION (INCLUDING CONTAINER)RESIDUAL WASTE:Chemical additions, processing or otherwise altering this material may make the waste management information presented in this MSDS incomplete, inaccurate or otherwiseinappropriate. Please be advised that state and local requirements for waste disposal may be more restrictive or otherwise different fromFederal laws and regulations. Consult state and local regulations regarding the proper disposal of this material.CONTAMINATED VESSELS AND CONTAINERS :Rinse containers before disposal. Do not allow rinsate to enter the water systems.EPA Hazardous Waste = No14. TRANSPORTATION INFORMATIONPROPER SHIPPING NAME: NOT REGULATED UN NUMBER:None UN CLASS or DIVISION: None UN PACKING GROUP: None LABELS :None EMERGENCY GUIDE#:None15. REGULATORY INFORMATIONInventory Status:US (TSCA): YesCanada (DSL): Yes EU (REACH): Yes Australia (AICS): Yes Japan (METI): Yes Korea (KECL): YesWhere: Yes = all ingredients are listed on the inventory, Exempt = All ingredients are either on the inventory or exempt from the requirements of listing, No = Not determined, or one or more ingredients are not on the inventory and are not exempt from listingSARA Title III Hazard Classes: Fire Hazard: No Reactive Hazard: No Release of Pressure: No Acute Health Hazard: Yes Chronic Health Hazard: YesSARA Extremely Hazardous Substances/CERCLA Hazardous Substances: Ethylene glycol (107-21-1) (33%), TPQ=5000 pounds, 2270 kgCalifornia Proposition 65: This product does not contain any components that are regulated under Proposition 65.SAFETY DATA SHEET: TEDA – L33E – US-GHS Version16. OTHER INFORMATION INCLUDING INFORMATION ON PREPARATION AND REVISION OF THIS MSDSNational Fire Protection Association (“NFPA”) Hazard Ratings: Health: 2 (Moderate)Flammability: 1 (Slight)Reactivity: 0 (Minimal)National Paint and Coatings Hazardous Materials Identification System (“HMIS”) Hazard Ratings: Health: 2 (Moderate)Flammability: 1 (Slight) Physical Hazard: 0 (Minimal)HISTORY: Date previous SDS: April 7, 2015 Date of issue: November 13, 2015 Reasons for Revision: Revised Phone NumberDisclaimer: The information set forth herein has been gathered from standard reference materials and/or TOSOH SPECIALTY CHEMICALS USA, INC and its related, subsidiary and affiliated companies’ test data and is to the best knowledge and belief of TOSOH SPECIALTY CHEMICALS USA, INC and its related, subsidiary and affiliated companies, accurate andreliable. Such information is offered solely for your consideration, investigation, and verification, and is not suggested or guaranteed that the hazard precautions or procedures mentioned are the only ones that exist. TOSOH SPECIALTY CHEMICALS USA, INC and its related, subsidiary and affiliated companies make no warranties, express or implied, and expressly disclaim any and all such warranties with respect to the use of such information or the use of specific materialidentified herein in combination with any other material or process, and assume no responsibility therefor. TOSOH SPECIALTY CHEMICALS USA, INC and its related, subsidiary and affiliated companies make no representation or warranty, express or implied, and EXPRESSLY DISCLAIM ANY AND ALL SUCH WARRANTIES, as to the usefulness, sufficiency, MERCHANTABILITY or FITNESS FOR ANY PURPOSE whatsoever of the materials identified herein. The purchaser bears sole responsibility for testing, evaluating and determining the suitability of these materials for whatever use(s), manufacturing and refining processes, and any other such application(s) for which it intends or ultimately makes of these materials. Purchaser bears sole responsibility for obtaining any and all regulatory, legal and governmental approval necessary for such use(s).END OF SAFETY DATA SHEETdistributed by:Request Quote or Samples。
Souriau 853系列高温防火连接器说明书
853 Series2 Souriau 853 series /interconnect853 seriesFirewall connectorsTypical applicationsSouriau 853 seriesT able of contentsTable of contents853 series overview (4)Product range (4)Available configurations (5)Contact layouts (6)Contact layouts matrix (9)853 series product range (10)8533 series - standard version (10)8534 series - scoop-proof version (17)8535/8536 series - integrated backshell version (21)8533 series - power & Quadrax version (27)8533 series - hermetic version (30)853 series common elements (36)Signal and power contacts (36)Thermocouple contacts (38)Contact ordering information (39)#8 Quadrax contacts (40)Sealing boots (40)Filler plugs (40)Wiring instructions (41)Tools (42)Tightening support & tool (43)Silicone gaskets (43)Protective caps (43)Dummy receptacle (44)Souriau 853 series /interconnect 3Souriau 853 series4 Souriau 853 series /interconnectProduct rangeSouriau 853 series• Quadrax contacts for high speed Ethernet networks • Power contacts for high power current under temperature and vibration • ABS qualified solutionQuadrax & power contacts See Page 27• For hermetic interface or space constrained application • Leak rate < 10-7 atm.cm3/s • Solder cup & PC tail contactsHermetic version SeePage 30• For blind mate connection • ESC11 qualified Scoop-proof SeePage 17• For weight saving solutions • ESC15 and ESC16 qualifiedIntegrated backshell SeePage 21Heat shrink boot Clamp collarEMI braid Integratedbackshell Standard version SeePage 10Souriau 853 seriesAvailable configurations 853 series configurations* Please consult us. **Only delivered without contact.Souriau 853 series /interconnect 5Souriau 853 series6 Souriau 853 series /interconnectContact layoutsContact layouts 8533/8535 seriesConnector type0801*03070504022#2012159#20, 3#1615#20Classes 200°C & 260°CClass 200°CFuel tank8533 only (ABS)Hermetic 200°C & 260°C (8533 only)* Q uadrax layout only, #8 Quadrax contact compatible with #6 cavity.Contact #20Contact #16Contact #12Contact #8 quadrax & Contact #6 powerContact #4 power4#15101#63#203#205#20066#2012033#161212#20147#160802143114#1631#202#6241010#161624#20188#12Souriau 853 series /interconnect 7Souriau 853 seriesContact layoutsContact layouts 8533/8535 series55391912322212#1219#1626#20, 6#1227#20, 12#1655#206157*300443*244#430#1623#20, 20#1655#20, 2#1261#204206286#642#163928160425204#616#1619#20, 6#1224#20, 4#1237#20, 2#1641#20Connector typeClasses 200°C & 260°CClass 200°CFuel tank8533 only (ABS)Hermetic 200°C & 260°C (8533 only)* Please consult us.Contact #20Contact #16Contact #12Contact #8 quadrax & Contact #6 powerContact #4 powerSouriau 853 series8 Souriau 853 series /interconnectContact layoutsContact layouts 8534/8536 seriesConnector typeClasses 200°C & 260°CClass 200°CFuel tank8533 only (ABS)Hermetic 200°C & 260°C (8533 only)Contact #20Contact #16Contact #12Contact #8 quadrax & Contact #6 powerContact #4 power141515#202424#20163131#20185555#20226161#2024392037#20, 2#164141#2020Souriau 853 series /interconnect 9Souriau 853 seriesContact layoutsContact layouts (matrix)Yes Souriau layoutQ Souriau layout & layout according to corresponding norm(1)Only developed for square flange receptacle all classes and stainless steel plug (for other configuration, please consult us)(2)Quadrax contact onlyShellABSpower & 8533EN2997 8533ESC108534ESC11Number of contactsTechnical specifications8533 series - standard version10 Souriau 853 series/interconnectDescription• Stainless steel screw coupling connector derived from MIL -C-83723, designed for use in harsh aviation environments • High vibration resistance • High temperature resistance (up to 260°C)• Fireproof (1100°C)• Qualified to EN2997 and ESC10 standards • Large array of EN3155 and ESC30 qualified crimp contacts• Size 12, 16 & 20 standard contacts • Size 12, 16 & 20 thermocouple contacts for temperature measurement• Fuel immersion version availableMechanicalShellAluminum alloy (class R, W and A) Stainless steel (class K, E and S)PlatingNickel (class R and S)Olive green cadmium (class W) Black anodized (class A) Passivated (class K and E)Grommet and seal Silicone elastomer InsulatorThermoplastic Contact body Copper alloy Contact plating Gold over nickel Contact retention Size 20: 90 N Size 16: 110 N Size 12: 130 NMating cycles250 mating cycles (class R, W and A) 500 mating cycles (class K, E and S)Shock300 m/s² (30g) during 3 ms VibrationRandom 5 Hz to 2000 Hz at 1G²/Hz (2 x 8 hours)ElectricalDielectric withstandingContact resistanceInitial contact resistance at ambienttemperature per EN 2997 and EN3155Insulation resistance 5000 MΩ at 500 VdcMax curent rating per contactElectrical continuity5 mΩ max with RFI shielding 60 mΩ without RFI shielding ShieldingTo 100 MHz at 1 GHz attenuation 65 dB Lightning strike (3K & 3E classes)15A according D0160, wave 5AEnvironmentalOperating temperature• Class W: -65° to +175°C (-149° to +347°F)• Class R, A and K: -65° to +200°C • (-149° to +392°F)• Class E and S: -65° to +260°C (-149° to +500°F)• Fuel tank long term immersion version specification 22 limited to +105°C max LeakagePer 2591-312:Method B differential pressure: 100kPa Maximum leakage flow: 16x10-6 m 3/h Salt spray48 hours (class R)500 hours (class W, K, E and A)Resistance to fluids MIL -H 5606 - SKYDROL 500 B4 - LD4 - JP5 - MIL -L 7870A - MIL -L 23699 - MIL - L 7808 - MIL -C 25769 - MIL -A 8243Fire resistancePer EN 2591-318:6 min under a 1100°C flame without electrical perturbation, plus 14 min with no flame propagation (ES class)Fuel resistance Standard version Per EN2997Long term immersion (specification 22):Per PrEN3645: 3 cycles of 96 hours in fuel8533 series - standard versionOrdering informationStandard connectors - part numbersEN2997 qualified productsTechnical specifications8533 series - standard versionESC10 qualified productsConnector weight Mass max. (g) less contactMass of crimp contactsNote:All dimensions are in millimeters (mm)Shell Square flange Jam nut PlugMass (g)DimensionsPlug30.22 maxB Thread3.3/4.83ØA8533 series - standard versionDimensionsNote: All dimensions are in millimeters (mm)Square flange receptacleDC 4 holes ØEØAØB31.5 max17.98/18.491.32/1.83Thread: see plug3.3/4.83Jam nut receptacle36 maxThread: see plugØABDØCDimensions8533 series - standard versionPanel cut outMaxOrientationFront face view of plugNA°B°D°C°Master keyNote: All dimensions are in millimeters (mm)8533 series - standard versionBackshellsAluminum shrink boot adaptersNote: All dimensions are in millimeters (mm)Shrink boot adapter (removable) Type 60-1Shrink boot adapter (non removable) Type 60-2GAB CDAluminum plastic collar EFGStraight plastic collar Type 5345° plastic collar Type 5490° plastic collar Type 55DACBACCE (s e l f l o c k i n g )Ground lug (G option)Dimensions8533 series - standard version Backnut and cable clampLength - mated/unmated connectors with backshellsBacknut - Type 31or Type 01 + Square flange receptacle + Plug+ Backnut - Type 31 or Type 01Backnut - Type 31 or Type 01+ Square flange receptacle + Plug+ Elbow cable clamp - Type 51Backnut - Type 31 or Type 01+ Square flange receptacle+ Plug+ Straight cable clamp -Type 52 or Type 02Shell C DBacknutType 31 (aluminum)Type 01 (stainless steel)Straight cable clampType 52 (aluminum)Type 02 (stainless steel)Elbow cable clampType 51 (aluminum)ØAØBCDGHEFDShell±0.7±0.15TorqueShell C DF (unmated)Note: All dimensions are in millimeters (mm)8534 series - scoop-proof versionTechnical specificationsDescription• Stainless steel screw couplingconnector designed for use in harshaviation engine environments• High vibration resistance• High temperature resistance (260°C)• Fireproof (1100° C)• Scoop-proof design enablesblind mating• Qualified to ESC11 standard• Fully interchangeable and intermateablewith ESC16 / 8536 connectors(integrated backshell version)• Large array of crimp contacts• Size 16 & 20 standard contacts• Size 16 & 20 thermocouple contacts• Fuel immersion version availableMechanicalShellPassivated stainless steel Grommet and sealSilicone elastomerInsulatorThermoplasticContact bodyCopper alloyContact platingGold over nickelContact retentionSize 20: 90 NSize 16: 110 NMating cycles500 mating / unmating operations Vibration & shockAccording to JES290-083: 41 grms (2 x 8 hours)ElectricalDielectric withstandingInsulation resistance5000 MΩ at 500 VdcMax current rating per contactContact resistanceInitial contact resistance at ambienttemperature per EN 2997 and EN315Electrical continuity5 mΩ with RFI shielding (6SE class)ShieldingTo 100 MHz at 1 GHz attenuation65 dBEnvironmentalT emperature range-65°C to +260°CLeakagePer 2591-312:Method B differential pressure: 100kPaMaximum leakage flow: 16x10-6 m3/hSalt spray500 hours (class W, K, E and A)Fire resistancePer EN 2591-318:6 min under a 1100°C flame withoutelectrical perturbation, plus 14 minwith no flame propagation (ES class)Resistance to fluidsMIL-H 5606 - SKYDROL 500 B4 - LD4 -JP5 - MIL-L 7870A - MIL-L 23699 -MIL- L 7808 - MIL-C 25769 - MIL-A 82438534 series - scoop-proof version Ordering informationSouriau part numbersESC11 qualified products8534 series - scoop-proof versionDimensionsT h r e a dØCABMaster key4.83/3.301.83/1.3218.49/17.9832.27 MaxPlugSquare flange receptacleNote: All dimensions are in millimeters (mm)Master KeyØBØAT h r e a d32.52 Max4.83/3.30Ordering information8534 series - scoop-proof versionPanel cut outOrientationConnector weightsMass of crimp contactsFront face view of plugNA°B°D°C°Master KeyMass max. (g) less contact Shell Plug withPlug without Receptacle Mass (g)MaxNote: All dimensions are in millimeters (mm)8535/8536 series - integrated backshell versionTechnical specificationsDescription• Stainless steel screw couplingconnector designed for use in harshaviation engine environments• High vibration resistance• High temperature resistance(200°C / 260°C)• Fireproof (1100°C)• Integrated backshell with a fullscoop-proof connection (8536 series)• Qualified to ESC15 (8535 series) andESC16 (8536 series) standard, andper the new EN2997 issuance• Fully interchangeable• 8535 series with BACC 63 CM-CN,EN2997 and ESC10 connectors• 8536 series with ESC11connectors• 8535 series intermateable with BACC63 CM-CN• Large array of crimp contacts (sameas for 8533 series)• Size 12, 16 & 20 standard contacts• Size 12, 16 & 20 thermocouplecontactsMechanicalShellPassivated stainless steel Grommet and sealSilicone elastomerInsulatorThermoplasticContact bodyCopper alloyContact platingGold over nickelContact retentionSize 20: 90 NSize 16: 110 NSize 12: 130 NMating cycles500 coupling operationVibration & shock• According to JES290-083: 41 grms, 2x 8 hours (ES class)• According to JES290-102: 35 grms, 60 hours (KV class)• According to EN2591: 5Hz to 2000Hz at 1G²/Hz (2x8 hours)ElectricalDielectric withstandingInsulation resistance5000 MΩ at 500 VdcMax current rating per contactSize 20: 7.5 ASize 16: 13 ASize 12: 23 AContact resistanceInitial contact resistance at ambienttemperature per EN 2997 and EN315Electrical continuity5 mΩ with RFI shieldingShieldingTo 100 MHz at 1 GHz attenuation65 dBEnvironmentalT emperature range-65°C to +260°CLeakagePer 2591-312:Method B differential pressure: 100kPaMaximum leakage flow: 16x10-6 m3/hSalt spray500 hoursFire resistancePer EN 2591-318:6 min under a 1100°C flame withoutelectrical perturbation, plus 14 minwith no flame propagation (ES class)Resistance to fluidsMIL-H 5606 - SKYDROL 500 B4 - LD4 -JP5 - MIL-L 7870A - MIL-L 23699 -MIL- L 7808 - MIL-C 25769 - MIL-A 8243Ordering information8535/8536 series - integrated backshell version8535 part numbers8536 part numbersNote: aluminum version, please consult us.* Please consult us.8535/8536 series - integrated backshell versionOrdering informationESC15/ESC16 qualified productEN2997 qualified product* Please consult us.* Please consult us.Dimensions8535/8536 series - integrated backshell versionDimensionsPlug - 8535/ESC15/EN2997 and 8536/ESC16Front face viewØA MaxMaster key41.522.12 Max13ØBØC44.1124.61 Max135.25/4.74ØBØC1.22/1.738535/ESC15/EN29978536/ESC16Tolerance on linear dimensions shall be ±0.25 unless otherwise specified.Note: All dimensions are in millimeters (mm). Knurl design vary according to norm.Knurl descriptionKnurl T ype 1Conform to:• EN2997• ESC15/ESC16High vibrationKnurl T ype 2Conform to:• ESC15/ESC168535/8536 series - integrated backshell versionDimensionsNote: All dimensions are in millimeters (mm). Knurl design vary according to norm.Square flange receptacle - 8535/ESC15/EN2997 and 8536/ESC16Square flange receptacle with clinch nut - 8535/ESC15/EN2997 and 8536/ESC16Master key1.83/1.3244.2513ØCØD18.49/17.98Front face viewBATolerance on linear dimensions shall be ±0.25 unless otherwise specified.Master key1.83/1.3244.2513ØCØD18.49/17.98Front face viewBA4 captive nut silver platedThreadTolerance on linear dimensions shall be ±0.25 unless otherwise specified.Dimensions8535/8536 series - integrated backshell versionOrientationFront face view of plug8535/ESC15 / EN29978536/ESC16NMaster KeyA°B°C°D°Connector weightsMass max. (g) less contactSquare flange Plug Note: All dimensions are in millimeters (mm)Mass of crimp contactsMass (g)Minimum space between square flange receptacles: see Page 20.8533 series - power & Quadrax versionTechnical specificationsDescription• Innovative connector that combinesresistance to high vibrations and hightemperatures with high power• Up to 80 amps continuous ratingat 260°C ambient temperature• 20% space-savings comparedwith other solutions• Contact size 6 & 4, as well as theability to use Quadrax contacts insize 6 cavity layouts• Standard strain relief backshellor spacer accessory to adapt tospecific backshells• Airbus ABS 1340-1343, 426-1427and 1452 qualified• Grounded insert option foroptimized Quadrax performance• Ideal for electro-mechanical actuatorpower supply, alternator and starterapplicationsMechanicalShellNickel plated aluminum (R class), passivated stainless steel(E & K classes)Grommet and sealSilicone elastomerInsulatorThermoplasticContact bodyCopper alloyContact platingGold over nickelContact retentionSize 4: 200NSize 8: 130NSize 6: 156NEndurance500 mating cycles (E & K classes), 250 mating cycles (R class) Vibration & shockAccording to EN 2997ElectricalDielectric withstandingInsulation resistance5000 MΩ at 500 VdcMax current rating per contactQuadrax: 4 size 24 inner contacts in asize 8 outer contactContact resistanceInitial < 0.4 mΩElectrical continuity5 mΩ with RFI shieldingShieldingTo 100 MHz at 1 GHz attenuation65 dBEnvironmentalT emperature range• Class R and K: -60°C to +200°C• C lass E and #6 contact: -60°C to+260°CLeakagePer 2591-312:Method B differential pressure: 100kPaMaximum leakage flow: 16x10-6 m3/hSalt spray48 hours (R class)500 hours (E & K classes)Fire resistancePer EN 2591-318:6 min under a 1100°C flame withoutelectrical perturbation, plus 14 minwith no flame propagation (ES class)Resistance to fluidsMIL-H 5606 - SKYDROL 500 B4 - LD4 -JP5 - MIL-L 7870A - MIL-L 23699 -MIL- L 7808 - MIL-C 25769 - MIL-A 82438533 series - power & Quadrax version Ordering informationSouriau part numbers8533 series - power & Quadrax versionDimensionsStrain relief backshellT h r e a dCABDHolesnumberNote:All dimensions are in millimeters (mm)Mass ±0.1±0.12Thread Coupling ±0.5SpacerSelf locking ring spacer31.9±1ØBØAStainless steelAluminumTechnical specifications8533 series - hermetic versionDescription• EN2997 and ESC10 qualified screwcoupling connector• High vibration resistance• High temperature resistance• Glass sealed hermetic• High hermeticity performance• Compact low profile• Several mounting styles• Compact solder mount receptacle• Easy to install square flange• Easy to replace jam nutreceptacle• Fully interchangeable with MIL83723 hermetic connectors• Special fuel tank versions available• 230V qualified versions used toreduce cable weight with highervoltageMechanicalShellPassivated stainless steelSealsSilicone elastomerContactFerrous alloyContact platingGoldShock300 m/s² (30g) during 3 ms Endurance500 mating/unmating operations Vibration & shockRandom 5 Hz to 2000 Hz at 1G²/Hz (2 x 8 hours)ElectricalMax current rating per contactDielectric withstanding voltageContact resistance at rated currentMaximum initial contact resistance atambient temperatureEnvironmentalOperating temperatureClass Y: -65°C to 200°CClass YE: -65°C to 260°C cyclicHermeticityLeak rate <10-7 atm.cm3/s(helium gas test)Damp heatPer EN 2997 and NFL 54143:10 cycles of 24hSalt spray500 hoursResistance to fluidsMIL-H 5606 - SKYDROL 500 B4 - LD4 -JP5 - MIL-L 7870A - MIL-L 23699 -MIL- L 7808 - MIL-C 25769 - MIL-A 8243Fuel immersion version105°C max per EN36458533 series - hermetic versionOrdering information Souriau part numbersEN2997 qualified products ESC10 qualified productsDimensions8533 series - hermetic versionNote: All dimensions are in millimeters (mm)Solder mount hermetic receptacle (Class Y &YE)Jam nut hermetic receptacle (Class Y & YE)8533 series - hermetic versionDimensionsNote:All dimensions are in millimeters (mm)Panel cut outMaxDimensionsSquare flange hermetic receptacle (Class Y & YE)Contacts8533 series - hermetic versionContact T ype 1: Solder mount receptacle T ype 2: Square flange receptacle T ype 7: Jam nut receptacleYØ ZØ ZX WYØ ZØ ZXW YØ ZØ Z X W Contact variations Cross reference list• • • • Shell size & layout □ OrientationConnector weights(in grams)Square flange Jam nutSolder mountNote: All dimensions are in millimeters (mm)Note: for other contact length, please consult us.SolderEyeletPCB8533 series - hermetic versionOrientationNote: All dimensions are in millimeters (mm)Front face view of receptacleNA°B°D°C°Master KeyGaskets & O-ringsGasket for square flange receptacle (not delivered with connector)O-ring for jam nut receptacle200°C class (delivered with connector)O-ring for jam nut receptacle260°C class (delivered with connector)Gasket for square flange receptacleAØDØCBSouriau 853 seriesSignal and power contactsIntroduction• Firewall contacts designed for highvibration and high temperature• Each contact type is qualified andvalidated by qualification organizationsor aerospace manufacturers• Size 12, 16 & 20 signal contacts:EN3155 and ESC30 qualified• Size 12, 16 & 20 thermocouplecontacts: EN3155 and ESC30qualified• Crimping, insertion and extractiontools are availableSignal and power contactsCrimp contacts 175°C and 200°CPart numbers Code Admissible wire section External Øover insulatorMass g(±15%)Souriau 853 seriesSignal and power contactsCrimp contacts 260°CCrimp contacts 200°C and 260°CPart numbersCode Admissible wire sectionExternal Øover insulator Mass g (±15%)Part numbersCode Admissible wire section External Øover insulator Mass g (±15%)Souriau 853 series Thermocouple contactsThermocouple contacts (-65°C to +260°C) Chromel - pin contacts (non magnetic)Code Admissiblewire sectionExternal Øover insulatorChromel - socket contacts (non magnetic)Code Admissiblewire sectionExternal Øover insulatorAlumel - pin contacts (magnetic)Code Admissiblewire sectionExternal Øover insulatorAlumel - socket contacts (magnetic)Code Admissiblewire sectionExternal Øover insulatorSouriau 853 seriesContactsContact ordering informationEN3155ESC30Souriau 853 seriesThermocouple contactsFiller plugsThese filler plugs are installed at the rear of unwired contacts to maintain connector sealing.in grommetFiller plugUnwired contact+Crimp contacts are unsealed. Sealing boots are available. All contacts delivered without boot.#8 Quadrax contactsSealing bootsABS 0992 for power & Quadrax contacts - Class 260°CASouriau 853 series /interconnect 41Souriau 853 seriesWiring instructionsCable preparation and wire strippingInsertion of wire in contact barrelWhen inserting the stripped wire into the contact barrel check that no strands are left outside and that the wire is visible through the wire inspection hole in the barrel.Important:• Slide any accessories over wire strands before carrying out the following operations.•Contacts are inserted and extracted from the rear of the connector.Contact201612L = length of wire strippingInsertion of the contacts1 - Engage the crimp cable / contact assembly into the longitudinal slot of the plastictool (colored tip). Slide the tool down the cable until the tip of the tool abuts thecontact retention shoulder332 - Introduce the contact into the required contact cavity in the insulator, pushing tool axially, until the contact snaps into position in clip.3 - Withdraw the tool from rear. Check that contact is firmly locked by pulling wire gently. When connector is fully loaded, check the position of contact tips. They should all be in the same plane. Note: For larger sizes of cable which are stiff enough, manual insertion without tool is preferable.1 - Engage the appropriate cable into the longitudinal slot of the tool with the white tip towards connector.Extraction of the contacts2 - Slide the tool down towards the contact. Insert the tool in the insulator until it abuts the contact shoulder.3 - Holding the tool-contact and cable assembly together, remove them simultaneously.Souriau 853 series42 Souriau 853 series /interconnectToolsInsertion and extraction toolsInsertion and extraction of wired contactsExtraction of unwired contactsExtraction toolPlastic extraction tool for #6 and 4Metallic extraction toolCrimping toolsPlastic insertion and extraction toolfor #20, 16 and 12WiresPart numbersPart numbersSouriau 853 series /interconnect 43Souriau 853 seriesAccessoriesBackshell tightening tool8498-03Backshell tightening plier,part number: 8498-03Square jaws (order 2 jaws),part number: 8500-1015Tightening support3450.3310±0.5Orientation N, 6 & 9Orientation 7, 8 & YAluminum version, part number: 8533-1150 (consult us)Stainless steel version, part number: 8533-1151Silicone gasketsShell Gasket for square flange receptacle O-Ring for jam nut recep. 200°C Class O-Ring for jam nut recep. 260°C Class Grounding ring replacement kit Please contact us.Protective capsReceptacle stainless steel capC Type134 MaxØ3.2MaxN TypeSouriau 853 series44 Souriau 853 series /interconnectDummy receptacleDummy receptacle stainless steel version19.3/20.321.45 MaxØCBAModelling receptacle aluminum version 19.35/19.8533.0 MaxB M a xA M axNote: Dummy receptacle without keying.Note: All dimensions are in millimeters (mm)For more information, contact us: /interconnect-support© 2023 EatonAll Rights Reserved Document No. TF700-8 October 2023Eaton is a registered trademark.All other trademarks are property of their respective owners.。
福西智库-外贸出口有毒有害物质控制全篇
PAHS报告
4、PHTHALATE指令
邻苯二甲酸酯(Phthalate ),是世界上生产量 大、应用面广的人工合成有机化合物之一
它可用作农药载体、驱虫剂、化妆品、香味品、 润滑剂和去污剂的生产原料,其中用量最大的是塑 料增塑剂,约占其总产量的80%。广泛用于聚氯乙 烯、聚丙烯、聚乙烯、聚苯乙烯的生产。
该标准将于2006年7月1日开始正式实施,主要 用于规范电子电气产品的材料及工艺标准,使之更 加有利于人体健康及环境保护。该标准的目的在于 消除电机电子产品中的铅、汞、镉、六价铬、多溴 联苯和多溴联苯醚共6项物质,并重点规定了铅的 含量不能超过0.1%。
ROHS报告
2、AZO染料
偶氮染料(azo dyes ),偶氮基两端连接芳基 的一类有机化合物(—N=N— )。偶氮染料是合 成染料中品种最多的一类,广泛用于多种天然和合 成纤维的染色和印花,也用于油漆、塑料、橡胶等 的着色。
NP报告
6、其它化学物质
❖ 甲醛 ❖ 致敏染料 ❖ PCP(五氯苯酚) ❖ VOCs(挥发性气体,包括甲苯等)
三、提问和谈论
谢谢你的参与!!!
PHTHALATE报告
5、NP指令
壬基酚(NP),是一种多用途的非离 子表面活性剂,是石油化学工业和有机合 成工业中最重要的中间体之一,具有优良 的去污、润湿和渗透、分散、增溶乳化性 能,被广泛用于日用洗涤剂、纺织工业中 精、粗纺呢绒的洗涤剂、橡胶塑料的防老 剂、着色剂、纺织印染助剂、农药乳化剂 等方面。
欧盟目前禁止偶氮染料中的24种致癌芳香胺。
AZO报告
3、PAHS指令
PAHs(多环芳烃,一种致癌物质),共有100多种化学结 构式的总称。
Safinamide_133865-89-1_DataSheet_MedChemExpress
Product Name:Safinamide CAS No.:133865-89-1Cat. No.:HY-70057Product Data SheetMWt:302.34Formula:C17H19FN2O2Purity :>98%Solubility:DMSOy Mechanisms:Biological Activity:Safinamide (EMD 1195686;FCE 26743)selectively and reversibly inhibits MAO B with IC50of 98 Pathways:Neuronal Signaling; Target:Monoamine Oxidase Safinamide (EMD 1195686; FCE 26743) selectively and reversibly inhibits MAO-B with IC50 of 98nM, exhibits 5918-fold selectivity against MAO-A.IC50 value: 98 nM [1]Target: MAO-B Safinamide (EMD 1195686; FCE 26743; ) is a highly selective and reversible monoamine oxidase type B (MAO-B) inhibitor that increases neostriatal dopamine concentration. In addition, Safinamide (EMD 1195686; FCE 26743; ) is voltage-dependent sodium and calcium channel blocker.Safinamide (EMD 1195686; FCE 26743; ) appears to bind to the batrachotoxin-sensitive site 2 of the voltage-sensitive sodium channels. Safinamide blocks N and L-type calcium channels and inhibits References:[1]. Leonetti F, et al. Solid-phase synthesis and insights into structure-activity relationships ofsafinamide analogues as potent and selective inhibitors of type B monoamine oxidase. J Med Chem,2007, 50(20), 4909-4916.g ypglutamate and aspartate release from synaptic terminals....[2]. Schapira AH.Safinamide in the treatment of Parkinson's disease.Expert Opin Pharmacother. 2010 Sep;11(13):2261-8.[3]. Onofrj M, et al.An expert opinion on safinamide in Parkinson's disease.Expert Opin Investig Drugs. 2008 Jul;17(7):1115-25.[4]Chazot PL Caution: Not fully tested. For research purposes onlyMedchemexpress LLC[4]. Chazot PL.Safinamide for the treatment of Parkinson's disease, epilepsy and restless legs syndrome.Curr Opin Investig Drugs. 2007 Jul;8(7):570-9.18 W i l k i n s o n W a y , P r i n c e t o n , N J 08540,U S AE m a i l : i n f o @m e d c h e m e x p r e s s .c o m W e b : w w w .m e d c h e m e x p r e s s .c om。
FLOCKSIL 1501(美国版)产品安全数据表说明书
USA SAFETY DATA SHEET3000010042631. CHEMICAL PRODUCT AND COMPANY IDENTIFICATIONProduct name: FLOCKSIL 1501 (US) Product Use/Class:Flock AdhesiveLORD Corporation 111 LORD DriveCary, NC 27511-7923 USATelephone: 814 868-3180Non-Transportation Emergency: 814 763-2345 Chemtrec 24 Hr Transportation Emergency No.800 424-9300 (Outside Continental U.S. 703 527-3887)EFFECTIVE DATE: 12/09/20192. HAZARDS IDENTIFICATIONGHS CLASSIFICATION:Flammable liquids Category 2Acute toxicity Inhalation - Vapours Category 4 - 46.6% of the mixture consists of ingredient(s) of unknown toxicity. Acute toxicity Inhalation - Dust and Mist Category 4 - 46.6% of the mixture consists of ingredient(s) of unknown toxicity.Serious eye damage/eye irritation Category 2A Skin sensitization Category 1Respiratory sensitization Category 1 Carcinogenicity Category 2Reproductive toxicity Category 2Specific target organ systemic toxicity (single exposure) Category 1 Respiratory system, Central nervous system, Kidney, LiverSpecific target organ systemic toxicity (single exposure) Category 3Specific target organ systemic toxicity (repeated exposure) Category 1 Respiratory system, Central nervous system, Nervous systemHazardous to the aquatic environment - acute hazardCategory 3 Hazardous to the aquatic environment - chronic hazardCategory 3GHS LABEL ELEMENTS:Symbol(s)Signal WordD ANGERHazard StatementsHighly flammable liquid and vapor. Harmful if inhaled.Causes serious eye irritation.May cause an allergic skin reaction.May cause allergy or asthma symptoms or breathing difficulties if inhaled. Suspected of causing cancer.Suspected of damaging fertility or the unborn child.Causes damage to organs.(Respiratory system, Central nervous system, Kidney, Liver) May cause drowsiness or dizziness. May cause respiratory irritation.Causes damage to organs through prolonged or repeated exposure.(Respiratory system, Central nervous system,Nervous system)Harmful to aquatic life.Harmful to aquatic life with long lasting effects.Precautionary StatementsPreventionKeep away from heat/sparks/open flames/hot surfaces. - No smoking.Ground/Bond container and receiving equipment.Use explosion-proof electrical/ventilating/lighting equipment.Use only non-sparking tools.Take precautionary measures against static discharge.Obtain special instructions before use.Do not handle until all safety precautions have been read and understood.Wear protective gloves/protective clothing/eye protection/face protection.Use personal protective equipment as required.In case of inadequate ventilation wear respiratory protection.Do not breathe dust/fume/gas/mist/vapors/spray.Wash thoroughly after handling.Do not eat, drink or smoke when using this product.Use only outdoors or in a well-ventilated area.Contaminated work clothing should not be allowed out of the workplace.Avoid release to the environment.ResponseIn case of fire: refer to section 5 of SDS for extinguishing media.Call a POISON CENTER or doctor/physician if you feel unwell.IF exposed: Call a POISON CENTER or doctor/physician.Specific treatment (see supplemental first aid instructions on this label).IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing.If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician.IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.If skin irritation or rash occurs: Get medical advice/attention.IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.Continue rinsing.Wash contaminated clothing before reuse.StorageStore in a well-ventilated place. Keep cool.Store in a well-ventilated place. Keep container tightly closed.Store locked up.Disposal:Dispose of contents/container in accordance with waste/disposal laws and regulations of your country or particular locality.Other Hazards:This product contains component(s) which have the following warnings; however based on the GHS classification criteria of your country or locale, the product mixture may be outside the respective category(s).Acute: Vapor harmful; may affect the brain or nervous system causing dizziness, headache or nausea. Possibleirritation of the respiratory system can occur causing a variety of symptoms such as dryness of the throat, tightness of the chest, and shortness of breath. May cause central nervous system depression characterized by the followingprogressive steps: headache, dizziness, staggering gait, confusion, unconsciousness or coma. May cause lungdamage. Animal tests have indicated that respiratory sensitization can result from skin contact with certainisocyanates.Chronic: May cause long-term lung damage. May affect the gastrointestinal system. Ethylbenzene has beenclassified by IARC as a possible human carcinogen (Group 2B) and reported by NTP to show clear evidence forcarcinogenicity in animals. IARC has designated Methyl isobutyl ketone to be in Group 2B - possibly carcinogenic to humans.3. COMPOSITION/INFORMATION ON INGREDIENTSChemical Name CAS Number RangeMethyl isobutyl ketone108-10-135 - 40%Ethyl acetate141-78-6 5 - 10%Xylene1330-20-7 1 - 5%4,4'-Diphenylmethane diisocyanate101-68-8 1 - 5%Epoxy novolac resin PROPRIETARY0.1 - 0.9%Ethyl benzene100-41-40.1 - 0.9%P-Toluene sulfonyl isocyanate4083-64-10.1 - 0.9%2-Hydroxy benzoic acid69-72-70.1 - 0.9%2,6-Di-tert-butyl-p-cresol128-37-00.1 - 0.9%Any "PROPRIETARY" component(s) in the above table is considered trade secret, thus the specific chemical and its exact concentration is being withheld.4. FIRST AID MEASURESFIRST AID - EYE CONTACT: Flush eyes immediately with large amount of water for at least 15 minutes holding eyelids open while flushing. Get prompt medical attention.FIRST AID - SKIN CONTACT: Flush contaminated skin with large amounts of water while removing contaminated clothing. Wash affected skin areas with soap and water. Get medical attention if symptoms occur.FIRST AID - INHALATION: Move person to fresh air. Restore and support continued breathing. If breathing is difficult, give oxygen. Get immediate medical attention.FIRST AID - INGESTION: If swallowed, do not induce vomiting. Call a physician or poison control center immediately for further instructions. Never give anything by mouth if victim is rapidly losing consciousness, unconscious or convulsing.5. FIRE-FIGHTING MEASURESSUITABLE EXTINGUISHING MEDIA: Carbon Dioxide, Dry Chemical, Foam, Water FogUNSUITABLE EXTINGUISHING MEDIA: Not determined for this product.SPECIFIC HAZARDS POSSIBLY ARISING FROM THE CHEMICAL: Flammable liquid and vapor. Keep containers tightly closed. Isolate from heat, electrical equipment, sparks, open flame, and other sources of ignition. Closed containers may rupture when exposed to extreme heat. Use water spray to keep fire exposed containers cool. During a fire, irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.SPECIAL PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIRE-FIGHTERS: Wear full firefighting protective clothing, including self-contained breathing apparatus (SCBA). Water spray may be ineffective. If water is used, fog nozzles are preferable.6. ACCIDENTAL RELEASE MEASURESPERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES: Remove all sources of ignition (flame, hot surfaces, and electrical, static or frictional sparks). Avoid contact. Avoid breathing vapors. Use self-contained breathing equipment.ENVIRONMENTAL PRECAUTIONS: Do not contaminate bodies of water, waterways, or ditches, with chemical or used container.METHODS AND MATERIALS FOR CONTAINMENT AND CLEANUP: Keep non-essential personnel a safe distance away from the spill area. Notify appropriate authorities if necessary. Avoid contact. Before attempting cleanup, refer to hazard caution information in other sections of the SDS form. Contain and remove with inert absorbent material and non-sparking tools.7. HANDLING AND STORAGEHANDLING: Keep closure tight and container upright to prevent leakage. Ground and bond containers when transferring material. Avoid skin and eye contact. Wash thoroughly after handling. Avoid breathing of vapor or spray mists. Do not handle until all safety precautions have been read and understood. Empty containers should not be re-used. Use with adequate ventilation. Because empty containers may retain product residue and flammable vapors, keep away from heat, sparks and flame; do not cut, puncture or weld on or near the empty container. Do not smoke where this product is used or stored.STORAGE: Do not store or use near heat, sparks, or open flame. Store only in well-ventilated areas. Do not puncture, drag, or slide container. Keep container closed when not in use. Refer to OSHA 29CFR Part 1910.106 "Flammable and Combustible Liquids" for specific storage requirements.INCOMPATIBILITY: Strong oxidizers, acids, bases, water.; Amines, acids, water, hydroxyl, or active hydrogen compounds.8. EXPOSURE CONTROLS/PERSONAL PROTECTIONCOMPONENT EXPOSURE LIMITChemical Name ACGIH TLV-TWA ACGIH TLV-STELOSHA PEL-TWAOSHA PEL-CEILINGSkinMethyl isobutyl ketone50 ppm75 ppm410 mg/m3100 ppmN.E.N.A.Ethyl acetate400 ppm N.E.1,400 mg/m3400 ppmN.E.N.A.Xylene100 ppm150 ppm435 mg/m3100 ppmN.E.N.A.4,4'-Diphenylmethane diisocyanate 0.005 ppm N.E.N.E. 0.2 mg/m30.02 ppmN.A.Epoxy novolac resin N.E.N.E.N.E. N.E.N.A.Ethyl benzene20 ppm N.E.435 mg/m3100 ppmN.E.N.A.P-Toluene sulfonylisocyanateN.E.N.E.N.E. N.E.N.A.2-Hydroxy benzoic acid N.E.N.E.N.E. N.E.N.A.2,6-Di-tert-butyl-p-cresol 2 mg/m3N.E.N.E. N.E.N.A.N.A. - Not Applicable, N.E. - Not Established, S - Skin DesignationEngineering controls: Sufficient ventilation in pattern and volume should be provided in order to maintain air contaminant levels below recommended exposure limits. Caution: Solvent vapors are heavier than air and collect in lower levels of the work area. Sufficient ventilation (using explosion-proof equipment) should be provided to prevent flammable vapor/air mixtures from accumulating.PERSONAL PROTECTION MEASURES/EQUIPMENT:RESPIRATORY PROTECTION: Use a NIOSH approved chemical/mechanical filter respirator designed to remove a combination of particulates and organic vapor if occupational limits are exceeded. For emergencysituations, confined space use, or other conditions where exposure limits may be greatly exceeded, use an approved air-supplied respirator. For respirator use observe OSHA regulations (29CFR 1910.134) or use in accordance with applicable laws and regulations of your country or particular locality. This product contains isocyanates which have poor odor warning properties. If occupational exposure limits are exceeded, a NIOSH approved supplied-airrespirator is required.SKIN PROTECTION: Use neoprene, nitrile, or rubber gloves to prevent skin contact.EYE PROTECTION: Use safety eyewear including safety glasses with side shields and chemical goggles where splashing may occur.OTHER PROTECTIVE EQUIPMENT: Use disposable or impervious clothing if work clothing contamination is likely. Remove and wash contaminated clothing before reuse.HYGIENIC PRACTICES: Wash hands before eating, smoking, or using toilet facility. Do not smoke in anychemical handling or storage area. Food or beverages should not be consumed anywhere this product is handled or stored. Wash thoroughly after handling.9. PHYSICAL AND CHEMICAL PROPERTIESTypical values, not to be used for specification purposes.ODOR: Solvent VAPOR PRESSURE: N.D.APPEARANCE: Brown VAPOR DENSITY: Heavier than Air PHYSICAL STATE: Liquid LOWER EXPLOSIVE LIMIT: 1 %(V)UPPER EXPLOSIVE LIMIT: 9 %(V)FLASH POINT: 55 °F, 12 °C SetaflashClosed CupBOILING RANGE: 77 - 141 °C EVAPORATION RATE: Faster than n-butyl-acetate.AUTOIGNITION TEMPERATURE:N.D.DENSITY: 0.95 g/cm3 - 7.91 lb/gal DECOMPOSITION TEMPERATURE:N.D. VISCOSITY, DYNAMIC: ≥20 mPa.s @ 25 °C ODOR THRESHOLD: N.D.VISCOSITY, KINEMATIC: ≥21 mm2/s @ 25 °CSOLUBILITY IN H2O: Insoluble VOLATILE BY WEIGHT: 52.19 %pH: N.A.VOLATILE BY VOLUME: 60.18 %FREEZE POINT: N.D. VOC CALCULATED: 4.12 lb/gal, 491 g/lN.D.COEFFICIENT OF WATER/OILDISTRIBUTION:LEGEND: N.A. - Not Applicable, N.E. - Not Established, N.D. - Not Determined10. STABILITY AND REACTIVITYHAZARDOUS POLYMERIZATION: Hazardous polymerization will not occur under normal conditions.STABILITY: Product is stable under normal storage conditions.CONDITIONS TO AVOID: High temperatures. Sources of ignition.INCOMPATIBILITY: Strong oxidizers, acids, bases, water.; Amines, acids, water, hydroxyl, or active hydrogen compounds.HAZARDOUS DECOMPOSITION PRODUCTS: Carbon dioxide, carbon monoxide, chlorine, hydrogen chloride, Phosgene, Monomeric isocyanate, traces of hydrogen cyanide, nitrogen dioxide11. TOXICOLOGICAL INFORMATIONEXPOSURE PATH: Refer to section 2 of this SDS.SYMPTOMS:Refer to section 2 of this SDS.TOXICITY MEASURES:Chemical Name LD50/LC50Methyl isobutyl ketone Oral LD50: Rat2,080 mg/kgDermal LD50: Rabbit3,000 mg/kgInhalation LC50: Rat2000 - 4000 ppm/4 hEthyl acetate Oral LD50: Rat5,620 mg/kgDermal LD50: Rabbit> 18,000 mg/kgInhalation LC50: Rat4000 ppm/4 hXylene Oral LD50: Rat3,500 mg/kgDermal LD50: Rabbit> 4,350 mg/kgInhalation LC50: Rat29.08 mg/l/4 h4,4'-Diphenylmethane diisocyanate Oral LD50: Rat31,600 mg/kgDermal LD50: rabbit> 5,000 mg/kgGHS LC50 (vapour): Acute toxicity point estimate11 mg/l/4 h GHS LC50(dust and mist): Acute toxicity point estimate1.5 mg/l/4 h Epoxy novolac resin N.D.Ethyl benzene Oral LD50: Rat3,500 mg/kgDermal LD50: Rabbit15,400 mg/kgInhalation LC50: Rat17.4 mg/l/4 hP-Toluene sulfonyl isocyanate Oral LD50: Rat2,234 mg/kgInhalation LC50: Rat>640 ppm/1 h2-Hydroxy benzoic acid Oral LD50: Rat891 mg/kgDermal LD50: Rat> 2 g/kgDermal LD50: Rat> 2 g/kg2,6-Di-tert-butyl-p-cresol Oral LD50: Rat> 2,930 mg/kgDermal LD50: Rat> 2,000 mg/kgGerm cell mutagenicity: No classification proposedCarcinogenicity: Category 2 - Suspected of causing cancer.Components contributing to classification: Methyl isobutyl ketone. Ethyl benzene.Reproductive toxicity: Category 2 - Suspected of damaging fertility or the unborn child.Components contributing to classification: Xylene. Ethyl benzene. 2-Hydroxy benzoic acid. 2,6-Di-tert-butyl-p-cresol.12. ECOLOGICAL INFORMATIONECOTOXICITY:Chemical Name EcotoxicityMethyl isobutyl ketone Fish: Pimephales promelas496 - 514 mg/l96 h flow-throughInvertebrates: Daphnia magna170 mg/l48 hPlants: Pseudokirchneriella subcapitata400 mg/l96 hEthyl acetate Fish: Pimephales promelas220 - 250 mg/l96 h flow-throughOncorhynchus mykiss484 mg/l96 h flow-throughOncorhynchus mykiss352 - 500 mg/l96 h semi-staticInvertebrates: Daphnia magna560 mg/l48 h StaticXylene Fish: Pimephales promelas13.4 mg/l96 h flow-throughOncorhynchus mykiss2.661 - 4.093 mg/l96 h StaticOncorhynchus mykiss13.5 - 17.3 mg/l96 hLepomis macrochirus13.1 - 16.5 mg/l96 h flow-throughLepomis macrochirus19 mg/l96 hLepomis macrochirus7.711 - 9.591 mg/l96 h StaticPimephales promelas23.53 - 29.97 mg/l96 h StaticCyprinus carpio780 mg/l96 h semi-staticCyprinus carpio> 780 mg/l96 hPoecilia reticulata30.26 - 40.75 mg/l96 h StaticInvertebrates: water flea3.82 mg/l48 hGammarus lacustris0.6 mg/l48 h4,4'-Diphenylmethane diisocyanate Fish: Species> 1,000 mg/l96 hInvertebrates: Daphnia magna> 1,000 mg/l48 hEpoxy novolac resin N.D.Ethyl benzene Fish: Oncorhynchus mykiss11.0 - 18.0 mg/l96 h StaticOncorhynchus mykiss4.2 mg/l96 h semi-staticPimephales promelas7.55 - 11 mg/l96 h flow-throughLepomis macrochirus32 mg/l96 h StaticPimephales promelas9.1 - 15.6 mg/l96 h StaticPoecilia reticulata9.6 mg/l96 h StaticInvertebrates: Daphnia magna1.8 - 2.4 mg/l48 hPlants: Pseudokirchneriella subcapitata4.6 mg/l72 hPseudokirchneriella subcapitata> 438 mg/l96 hPseudokirchneriella subcapitata2.6 - 11.3 mg/l72 h StaticPseudokirchneriella subcapitata1.7 - 7.6 mg/l96 h StaticP-Toluene sulfonyl isocyanate N.D.2-Hydroxy benzoic acid Invertebrates: Daphnia magna870 mg/l48 h Static2,6-Di-tert-butyl-p-cresol Plants: Pseudokirchneriella subcapitata6 mg/l72 hDesmodesmus subspicatus> 0.42 mg/l72 hPERSISTENCE AND DEGRADABILITY:Not determined for this product.BIOACCUMULATIVE: Not determined for this product.MOBILITY IN SOIL: Not determined for this product.OTHER ADVERSE EFFECTS: Not determined for this product.13. DISPOSAL CONSIDERATIONSDISPOSAL METHOD: Disposal should be done in accordance with Federal (40CFR Part 261), state and local environmental control regulations. If waste is determined to be hazardous, use licensed hazardous waste transporter and disposal facility.14. TRANSPORT INFORMATIONUS DOT RoadProper Shipping Name: AdhesivesHazard Class: 3SECONDARY HAZARD: NoneUN/NA Number: 1133Packing Group: IIEmergency Response Guide Number: 128IATA CargoPROPER SHIPPING NAME: AdhesivesHazard Class: 3HAZARD CLASS: NoneUN NUMBER: 1133PACKING GROUP: IIEMS: 3LIMDGPROPER SHIPPING NAME: AdhesivesHazard Class: 3HAZARD CLASS: NoneUN NUMBER: 1133PACKING GROUP: IIEMS: F-EThe listed transportation classification applies to non-bulk shipments. It does not address regulatory variations due to changes in package size, mode of shipment or other regulatory descriptors. For the most accurate shipping information, refer to your transportation/compliance department.15. REGULATORY INFORMATIONU.S. FEDERAL REGULATIONS: AS FOLLOWS:SARA SECTION 313This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendment and Reauthorization Act of 1986 and 40 CFR part 372.:Chemical Name CAS Number Weight % Less ThanMethyl isobutyl ketone108-10-140.0%Xylene1330-20-7 5.0%4,4'-Diphenylmethane diisocyanate101-68-8 5.0%Ethyl benzene100-41-40.9%TOXIC SUBSTANCES CONTROL ACT:INVENTORY STATUSThe chemical substances in this product are on the TSCA Section 8 Inventory.EXPORT NOTIFICATIONThis product contains the following chemical substances subject to the reporting requirements of TSCA 12(B) if exported from the United States:None16. OTHER INFORMATIONUnder HazCom 2012 it is optional to continue using the HMIS rating system. It is important to ensure employees have been trained to recognize the different numeric ratings associated with the HazCom 2012 and HMIS schemes.HMIS RATINGS - HEALTH: 2* FLAMMABILITY: 3 PHYSICAL HAZARD: 1* - Indicates a chronic hazard; see Section 2Revision: Section 2, Section 11Effective Date: 12/09/2019DISCLAIMERThe information contained herein is, to the best of our knowledge and belief, accurate. However, since the conditions of handling and use are beyond our control, we make no guarantee of results, and assume no liability for damages incurred by use of this material. It is the responsibility of the user to comply with all applicable federal, state and local laws and regulations.。
CR17335 Data Sheet说明书
2.9
0 year
2.8
5 equivalent years*
10 equivalent years**
2.7 0
20
40
60
80
Depth of discharge (%)
1750 mAh: 100%
*After storage for 28 days at 80 deg. C **After storage for 57 days at 80 deg. C
Hitachi Maxell Energy, Ltd.
• Data and dimensions are not guaranteed. For further details, please contact us at your nearest Maxell office.
• Contents on this website are subject to change without notice.
Date of issue: April 2011
Diameter Height UL Recognition 5FDIOJDJBO3FQMBDFBCMF
CR17335 Manganese Dioxide-Li/Organic Electrolyte 3 1750 5 –40 to +85 16
17 33.5 MH12568
Available Terminals and Wire Connectors Check /products/industrial/battery/cir/pdf/cr17335tw_11e.pdf for diagrams of batteries with terminals.
Data Sheet
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Product Name:
Safinamide CAS No.:
133865-89-1Cat. No.:
HY-70057Product Data Sheet
MWt:
302.34Formula:
C17H19FN2O2Purity :>98%
Solubility:
DMSO
y Mechanisms:
Biological Activity:
Safinamide (EMD 1195686;FCE 26743)selectively and reversibly inhibits MAO B with IC50of 98 Pathways:Neuronal Signaling; Target:Monoamine Oxidase Safinamide (EMD 1195686; FCE 26743) selectively and reversibly inhibits MAO-B with IC50 of 98
nM, exhibits 5918-fold selectivity against MAO-A.
IC50 value: 98 nM [1]
Target: MAO-B Safinamide (EMD 1195686; FCE 26743; ) is a highly selective and reversible monoamine oxidase type B (MAO-B) inhibitor that increases neostriatal dopamine concentration. In addition, Safinamide (EMD 1195686; FCE 26743; ) is voltage-dependent sodium and calcium channel blocker.
Safinamide (EMD 1195686; FCE 26743; ) appears to bind to the batrachotoxin-sensitive site 2 of the voltage-sensitive sodium channels. Safinamide blocks N and L-type calcium channels and inhibits References:
[1]. Leonetti F, et al. Solid-phase synthesis and insights into structure-activity relationships of
safinamide analogues as potent and selective inhibitors of type B monoamine oxidase. J Med Chem,
2007, 50(20), 4909-4916.g yp
glutamate and aspartate release from synaptic terminals....
[2]. Schapira AH.
Safinamide in the treatment of Parkinson's disease.
Expert Opin Pharmacother. 2010 Sep;11(13):2261-8.
[3]. Onofrj M, et al.
An expert opinion on safinamide in Parkinson's disease.
Expert Opin Investig Drugs. 2008 Jul;17(7):1115-25.
[4]Chazot PL Caution: Not fully tested. For research purposes only
Medchemexpress LLC
[4]. Chazot PL.
Safinamide for the treatment of Parkinson's disease, epilepsy and restless legs syndrome.
Curr Opin Investig Drugs. 2007 Jul;8(7):570-9.
18 W i l k i n s o n W a y , P r i n c e t o n , N J 08540,U S A
E m a i l : i n f o @m e d c h e m e x p r e s s .c o m W e b : w w w .m e d c h e m e x p r e s s .c o m。