BCV26-ZFD中文资料

合集下载

BYV26资料

BYV26资料
Fig.4 Maximum average forward current as a function of ambient temperature (including losses due to reverse leakage).
0
0
100
Tamb (oC)
200
BYV26F and G a = 1.42; VR = VRRMmax; δ = 0.5. Device mounted as shown in Fig.19. Switched mode application.
元器件交易网
DISCRETE SEMICONDUCTORS
DATA SHEET
handbook, 2 columns
M3D116
BYV26 series Fast soft-recovery controlled avalanche rectifiers
Product specification Supersedes data of February 1994
MSA856
handbook, h1alfpage I F(AV) (A)
0.5
MLB534
0
0
100
Tamb (oC)
200
BYV26A to E a = 1.42; VR = VRRMmax; δ = 0.5. Device mounted as shown in Fig.19. Switched mode application.
Ttp = 85 °C; lead length = 10 mm; see Figs 2 and 3; averaged over any 20 ms period; see also Figs 10 and 11

06.LXM26D_用户手册_V107_ZH

06.LXM26D_用户手册_V107_ZH

5.3 5.4 5.5
6
运行 6.1 6.2 6.3 访问通道 运行状态 6.2.1 状态图 运行模式 6.3.1 设置运行模式 6.3.2 Jog-模式 6.3.3 运行模式 Pulse Train (PT) 6.3.3.1 脉冲设置 6.3.3.2 传动系数 6.3.3.3 加速和减速的限制 6.3.4 运行模式 Position Sequence (PS) 6.3.4.1 数据组的结构 6.3.4.2 比例 6.3.4.3 用于绝对运动的 Homing 数据组 6.3.5 运行模式 Velocity (V) 和 Velocity Zero (Vz) 6.3.5.1 加速和减速 6.3.6 运行模式 Torque (T) 和 Torque Zero (Tz) 数字信号输入和输出的设置 6.4.1 信号输入的预设置 6.4.2 信号输入功能的参数设定 6.4.3 信号输出的预设置 6.4.4 信号输出功能的参数设定 目标值处理功能 6.5.1 用 HALT 中断运动 6.5.2 用 OPST 停止运动 强制数字信号输入 强制数字信号输出
在尝试安装、操作或维护设备之前,请仔细阅读下述说明并通过查看来 熟悉设备。下述特别信息可能会在本文其他地方或设备上出现,提示用 户潜在的危险,或者提醒注意有关阐明或简化某一过程的信息。 在“危险”标签上添加此符号表示存在触电危险,如果不遵 守使用说明,会导致人身伤害。 这是提醒注意安全的符号。提醒用户可能存在人身伤害的危 险。请遵守所有带此符号的安全注意事项,以避免可能的人 身伤害甚至死亡。
LXM26D 和 BCH2
伺服驱动系统 产品手册
V1.07, 11.2015
0198441114052, V1.07, 11.2015

LXM26D 和 BCH2

惠而浦洗碗机使用说明书

惠而浦洗碗机使用说明书

使用說明書Model : WFC3C26FUK 產品型號 : WFC3C26FUK User Manual2繁體中文316INDEXUSER MANUAL33GUIDETHANK YOU FOR BUYING A WHIRLPOOL PRODUCT.In order to receive a more complete assistance, pleaseregister your appliance on:Before using the appliance carefully read Health and Safety guide. PRODUCT DESCRIPTIONAPPLIANCE3.Multizone button with indicator light / Key lock4.Eco program indicator light5.Key lock indicator light6.Display7.Program number and remaining time indicator 10.Rinse Aid refill indicator light11.Salt refill indicator light12.Sani Rinse button with indicator light / Tablet (Tab)13.Delay button with indicator light14.Start/Pause button with indicator light / Drain outFIRST TIME USESALT, RINSE AID AND DETERGENTADVICE REGARDING THE FIRST TIME USEAfter installation, remove the stoppers from the racks and the retaining elastic elements from the upper rack.FILLING THE SALT RESERVOIRThe use of salt prevents the formation of LIMESCALE on the dishes and on the machine’s functional components.•It is important that the salt reservoir be never empty.•It is important to set the water hardness.The salt reservoir is located in the lower part of the dishwasher (see PROGRAMS DESCRIPTION)and should be lled when the SALT REFILL indicator light in the control panel is lit.1.Remove the lower rack and unscrew thereservoir cap (anticlockwise).2.Position the funnel (see gure) and ll the saltreservoir right up to its edge (approximately 1 kg);it is not unusual for a little water to leak out.3.Remove the funnel and wipe any salt residueaway from the opening.Make sure the cap is screwed on tightly, so that no detergent can get into the container during the wash program (this could damage the water softener beyond repair).Whenever you need to add salt, we recommend carrying out the procedure before the washing cycle is started.SETTING THE WATER HARDNESSTo allow the water softener to work in a perfect way, it is essential that the water hardness setting is based on the actual water hardness in your house. This information can be obtained from your local water supplier.The factory setting is for average (3) water hardness.•Switch on the appliance by pressing the ON/OFF button.•Switch o the appliance by pressing the ON/OFF button.•Hold down button START/PAUSE for 5 seconds, until you hear a beep.•Switch on the appliance by pressing the ON/OFF button.•The current selection level number and the salt indicator light both ash.•Press button P to select the desired hardness level (see WATER HARDNESS TABLE).•Switch o the appliance by pressing the ON/OFF button.Setting is complete!As soon as this procedure is complete, run a program without loading. Only use salt that has been speci cally designed for dishwashers.After the salt has been poured into the machine, the SALT REFILL indicator light switches o .If the salt container is not filled, the water softener and the heating element may be damaged as a result.FILLING THE RINSE AID DISPENSERRinse aid makes dish DRYING easier. The rinse aid dispenser A shouldbe lled when the RINSE AID REFILL indicator light in the1.2.Carefully introduce the rinse aid as far as the maximum (110 ml)reference notch of the lling space - avoid spilling it. If this happens,clean the spill immediately with a dry cloth.3.Press the lid down until you hear a click to close it.NEVER pour the rinse aid directly into the tub.ADJUSTING THE DOSAGE OF RINSE AIDIf you are not completely satis ed with the drying results, you can ad-just the quantity of rinse aid used.•Switch the dishwasher on using the ON/OFF button.•Switch it o using the ON/OFF button.•Press button START/PAUSE three times - a beep will be heard.•Switch it on using the ON/OFF button.•The current selection level number and rinse aid indicator light ash.•Press button P to select the level of rinse aid quantity to besupplied.•Switch it o using the ON/OFF button.Setting is complete!If the rinse aid level is set to 1(ECO), no rinse aid will be supplied. TheLOW RINSE AID indicator light will not be lit if you run out of rinse aid. Amaximum of 4 levels can be set according to the dishwasher model.The factory setting is for a medium level.•If you see bluish streaks on the dishes, set a low number (2-3).•If there are drops of water or limescale marks on the dishes, set ahigh number (4-5).FILLING THE DETERGENT DISPENSERopen the detergent dispenserthe amount of detergent formaximum quantity of liquid or powder detergent that can be addedto each cycle.2.Remove detergent residues from the edges of the dispenser andclose the cover until it clicks.3.Close the lid of the detergent dispenser by pulling it up until theclosing device is secured in place.The detergent dispenser automatically opens up at the right timeaccording to the program. If all-in-one detergents are used, werecommend using the TABLET button, because it adjusts the programso that the best washing and drying results are always achieved.Water Hardness TableLevel°dH°fH1Soft0 - 60 - 102Medium7 - 1111 - 203Average12 - 1721 - 304Hard17 - 3431 - 605Very hard35 - 5061 - 90measuring out the detergentEN PROGRAMS TABLE*) Not all options can be used simultaneously.**) The duration of the program shown on the display or in the booklet is an estimate calculated on standard conditions. The actual time may vary depending on many factors such as temperature and pressure of the incoming water, room temperature, amount of detergent, quantity and type of load, load balancing, additional selected options and sensor calibration. The sensor calibration can increase program duration up to 20 min. Standby consumption: Left-on mode consumption: 5 W - O mode consumption: 0.5 WPROGRAMS DESCRIPTIONInstructions on wash cycle selection.ECONormally soiled crockery. Standard program, the most e cient in terms of its combined energy and water consumption.6th SENSE ®For normally soiled dishes with dried food residues. Senses the level of soiling on the dishes and adjusts the program accordingly. When the sensor is detecting the soil level an animation appears in the display and the cycle duration is updated.INTENSIVEProgram recommended for heavily soiled crockery, especially suitable for pans and saucepans (not to be used for delicate items).DAILYNormally soiled crockery. Everyday cycle, that ensures optimal cleaning performance in shorter time.SILENTSuitable for night-time operation of the appliance. Optimum performance ensured.RAPID 30’Program to be used for lightly-soiled dishes with no dried food residues. Ideal for 2 place settings.CRISTALCycle for delicate items, which are more sensitive to high temperatures, for example glasses and cups.PRE-WASHCrockery to be washed later. No detergent to be used with this program.Notes:Optimum performance levels when using the “Rapid” program can be achieved by observing the maximum amounts of speci ed place settings.To reduce consumption even further, only run the dishwasher when it is full.OPTIONS AND FUNCTIONSOPTIONS can be selected directly by pressing the corresponding button (see CONTROL PANEL).MULTIZONEIf there are not many dishes to be washed, a half loadingmay be used in order to save water, electricity anddetergent.Select the program and then press the MULTIZONEbutton: the indicator over the button lights up and thesymbol of the chosen rack will appear on the display. Bydefault the appliance washes dishes in all racks.To wash only the speci c rack, press this buttonrepeatedly:shown on the display (only lower rack)shown on the display (only upper rack)shown on the display (only cutlery rack)shown on the display (option is OFF and the appliance willwash dishes in all racks).Remember to load the upper or lower rack only, andto reduce the amount of detergent accordingly.SANI RINSEThis option allows higher temperatures to be used.Select the washing program, press the SANI RINSEbutton; the indicator light will light up. To deselect theoption, press the same button again. Ideal to cleancrockery and feeding bottles. The dishwasher door mustbe kept shut for the entire duration of the program inorder to guarantee reduction of germs. If the door isopened the indicator lamp starts ashing.WARNING: the crockery and plates could beextremely hot at the end of the cycle.TABLETThis setting allows you to optimize the performance ofthe program according to the type of detergent used.Press the SANI RINCE button for 3 seconds(the corresponding symbol will light up) if you usecombined detergents in tablet form (rinse aid, salt anddetergent in 1 dose).If you use powder or liquid detergent, this optionshould be o .DELAYThe start of the program may be delayed for a period of time between 0:30 and 24 hours.1.Select the program and any desired options. Press the DELAY button (repeatedly) to delay the start of the program. Adjustable from 0:30 to 24 hours. With each press of the button, the delay start increases by: 0:30 if selection below 4 hours, 1:00 if selection is below 12 hours, 4 hours if selection is above 12 hours. If 24 hours reached, and the button is pressed, the delayed start is deactivated.2. Press the START/PAUSE button: the timer will begin counting down;3. Once this time has elapsed, the indicator light switches o and the program begins automatically.If at the time of the countdown the START/PAUSE button is pressed again the DELAY option is cancelled and the selected program starts automatically.The DELAY function cannot be set once a program has been started.KEYLOCKA long press (for 3 seconds) of MULTIZONE button, will activate the KEYLOCK function. The KEYLOCK function will block the control panel except the ON/OFF button. To deactivate the KEYLOCK, long press again.WATER TAP CLOSED – AlarmFlashes when there is no inlet water or water tap is closed.DRAIN OUTTo stop and cancel the active cycle, the Drain Out function can be used.A long press of START/PAUSE button, will activate the DRAIN OUT function. The active program will be stopped and the water in the dishwasher will be drained out.If an option is not compatible with the selected program seePROGRAMS TABLE, the corresponding LED ashes rapidly 3 timesand beeps will sound. The option will not be enabled.NaturalDryNaturalDry is a convection drying system which automatically opensthe door during/after drying phase to ensure exceptional dryingperformance every day. Door opens at the temperature that is safe toyour kitchen furniture, thus door will not be opened when the optionof SANI RINSE or TURBO are on.As additional steam protection, special designed protection foil isadded together with the dishwasher (depending on the model type -can be the need to buy it). To see how to mount protection foil pleaserefer to (INSTALLATION GUIDE).NaturalDry f unctionality could be disabled by the user as follows:•To DISABLE: Switch On, then switch Off the machine. Keep the "P"button pressed for 5 sec., at the end of 5 sec the dishwasher plays along beep. Switch On the machine, the display shows "o OF"•To ENABLE: Switch On, then switch Off the machine. Keep the "P"button pressed for 5 sec., at the end of 5 sec the dishwasher plays along beep. Switch On the machine, the display shows "oOn"EN DAILY USE1.CHECK WATER CONNECTIONCheck that the dishwasher is connected to the water supply and that the top is open.2.SWITCH ON THE DISHWASHERPress the ON/OFF button.3.LOAD THE RACKS(see LOADING THE RACKS)4.FILLING THE DETERGENT DISPENSER(see PROGRAMS TABLE).5.CHOOSE THE PROGRAM AND CUSTOMISE THE CYCLESelect the most appropriate program in accordance with the type of crockery and its soiling level (see PROGRAMS DESCRIPTION) by pressing the P button.Select the desired options (see OPTIONS AND FUNCTIONS).6.STARTStart the wash cycle by pressing the START/PAUSE button. When the program starts you hear a beep.7.END OF WASH CYCLEThe end of the wash cycle is indicated by beeps and the display shows END. Open the door and switch off the appliance by pressing the ON/OFF button.Wait for a few minutes before removing the crockery - to avoid burns.Unload the racks, beginning with the lower one.The machine will switch o automatically during certain extended periods of inactivity, in order to minimise electricity consumption. If the crockery is only lightly soiled or if it has been rinsed with water before being placed in the dishwasher, reduce the amount of detergent used accordingly.MODIFYING A RUNNING PROGRAMIf a wrong program was selected, it is possible to change it, provided that it has only just begun: press and hold the ON/OFF button, the machine will switch o . Switch the machine back on using the ON/OFF button and select the new wash cycle and any desired options; start the cycle by pressing the START/PAUSE button.ADDING EXTRA CROCKERYWithout switching off the machine, open the door (be ware of HOT steam!) and place the crockery inside the dishwasher. Close the door and press the START/PAUSE button the cycle will begin from the point at which it was interrupted.ACCIDENTAL INTERRUPTIONSIf the door is opened during the wash cycle, or if there is a power cut, the cycle stops. Once the door has been closed or the electricity supply is restored, to start again the cycle from where it was interrupted, press the START/PAUSE button.ADVICE AND TIPSTIPSBefore loading the baskets, remove all food residues from the crockery and empty the glasses. You do not need to rinse beforehand under running water.Arrange the crockery so that it is held in place rmly and does not tip over; and arrange the containers with the openings facing downwards and the concave/convex parts placed obliquely, thus allowing the water to reach every surface and ow freely.Warning:lids, handles, trays and frying pans do not prevent the sprayer arms from rotating.Place any small items in the cutlery basket.Very soiled dishes and pans should be placed in the lower basket because in this sector the water sprays are stronger and allow a higher washing performance.After loading the appliance, make sure that the sprayer arms can rotate freely.HYGIENETo avoid odour and sediment which can be accumulated in the dishwasher, please run a high temperature program at least one a month. Use a tea spoon of detergent and run it without the loading to clean your appliance.UNSUITABLE CROCKERY• Wooden crockery and cutlery.• Delicate decorated glasses, artistic handicraft and antique crockery. Their decorations are not resistant.• Parts in synthetic material which do not withstand high temperatures.• Copper and tin crockery.• Crockery soiled with ash, wax, lubricating grease or ink.The colours of glass decorations and aluminium/silver pieces can change and fade during the washing process. Some types of glass (e.g. crystal objects) can become opaque after a number of wash cycles too.DAMAGE TO GLASS AND CROCKERY• Only use glasses and porcelain guaranteed by the manufacturer as dishwasher safe.• Use a delicate detergent suitable for crockery.• Collect glasses and cutlery from the dishwasher as soon as the wash cycle is over.Load delicate and light dishes:glasses, cups, saucers, low saladbowls.(loading example for the upper rack)ADJUSTING THE HEIGHT OF THE UPPER RACKThe height of the upper rack can be adjusted: high position to place bulky crockery in the lower basket and low position to make the most of the tip-up supports by creating more space upwards and avoid collision with the items loaded into lower rack.The upper rack is equipped with a UpperRack height adjuster(see figure), withoutpressing the levers, lift it up by simplyholding the rack sides, as soon as the rackis stable in its upper position.To restore to the lower position, press thelevers A at the sides of the rack and movethe basket downwards.We strongly recommend that you donot adjust the height of the rack when itis loaded.NEVER raise or lower the basket on one side only.The side foldable flaps can be positioned atthree different heights to optimize thearrangement of crockery inside the rack.Wine glasses can be placed safely in thefoldable flaps by inserting the stem of eachglass into the corresponding slots.For optimum drying results incline thefoldable flaps more. To change theinclination, pull up the foldable flap, slide itslightly and position it as you wish.LOWER RACKFor pots, lids, plates, salad bowls, cutlery etc. Large plates and lids should ideally be placed at the sides to avoid interferences with theThe lower rack has tip-up supports which can be used in a verticalposition when arranging plates or in a horizontal position (lower) toload pans and salad bowls easily.CUTLERY RACKThe third rack was designed tohouse the cutlery.Arrange the cutlery as shownin the figure.A separate arrangement ofthe cutlery makes collectioneasier after washing andimproves washing and dryingperformance.Knives and other utensils with sharp edges must be positionedwith the blades facing downwards.The geometry of the rackmakes it possible to placesuch small items as coffeecups in the area in themiddle.FOLDABLE FLAPS WITH ADJUSTABLE POSITIONCLEANING THE FILTER ASSEMBLYRegularly clean the filter assembly so that the filters do not clog and that the waste water flows away correctly.The filter assembly consists of three filters which remove food residues from the washing water and then recirculate the water: to obtain the best washing results, you need to keep them clean.The dishwasher must not be used without filters or if the filter is loose.After several washes, check the filter assembly and if necessary clean it thoroughly under running water, using a non-metallic brush and following the instructions below:1.Turn the cylindrical filter A in an anti-clockwise direction and pull itout (Fig 1).2.Remove the cup filter B by exerting a slight pressure on the sideflaps (Fig 2).3.Slide out the stainless-steel plate filter C (Fig 3).4.Inspect the trap and remove any food residues. NEVER REMOVE theAfter cleaning the filters, re-place the filter assembly and fix itin position correctly; this is essential for maintaining the efficient operation of the dishwasher.CLEANING THE SPRAY ARMSOn occasions, food residue may become encrusted onto the spray arms and block the holes used to spray the water. It is therefore recommended that you check the arms from time to time and clean them with a small non-metallic brush.clockwise direction. The upper spray arm should be replaced so that the side with the greater number of holes is facing upwards.CLEANING THE WATER INLET HOSEIf the water hoses are new or have not been used for an extended period of time, let the water run to make sure it is clear and free of impurities before performing the necessary connections. If this precaution is not taken, the water inlet could become blocked and damage the dishwasher.MAINTENANCE AND TROUBLESHOOTING GUIDEFor more information, see the Use and Care Guide.The Use and Care Guide can be obtained by:•After-Sales Service, phone number see in warranty booklet.• Download from website: When you contact the After-Sales Service, you must provide the codes shown on the rating plate attached to the left or right side inside the door of the dishwasher. The phone number is listed in the warranty booklet or on the website: Your dishwasher may not work properly.Before contacting the Service Centre check if the problem can be solved by going through the following list. PROBLEMS POSSIBLE CAUSES SOLUTIONSThe dishwasher won’t start or does not respond to commands.The appliance has not been plugged inproperly.Insert the plug into the socket.Power outage.The dishwasher starts automatically when the power returns.The dishwasher door is not closed.Vigorously push the door until you hear the “click”.It does not respond to commands.Switch o the appliance by pressing the ON/OFF button, switch it back onafter approximately one minute and reset the program.The dishwasher won’t drain.The wash cycle has not nished yet.Wait until the wash cycle nishes.The drain hose is bent.Check that the drain hose is not bent (see INSTALATION INSTRUCTION). The sink drain pipe is blocked.Clean the sink drain pipe.The lter is clogged up with food residues.Clean the lter (see CLEANING THE FILTER ASSEMBLY).The dishwasher makes excessive noise.The dishes are rattling against each.Arrange the crockery correctly (see LOADING THE RACKS).An excessive amount of foam has beenproduced.The detergent has not been measured out correctly or it is not suitable foruse in dishwashers (see FILLING THE DETERGENT DISPENSER). Reset dish-washer by pressing the DRAIN button (see OPTIONS AND FUNCTIONS) andrun new program without detergent.The dishes are not clean.The crockery has not been arrangedproperly.Arrange the crockery correctly (see LOADING THE RACKS).The spray arms cannot rotate freely,being hindered by the dishes.Arrange the crockery correctly (see LOADING THE RACKS).The wash cycle is too gentle.Select an appropriate wash cycle (see PROGRAMS TABLE).An excessive amount of foam has beenproduced.The detergent has not been measured out correctly or it is not suitable foruse in dishwashers (see FILLING THE DETERGENT DISPENSER).The cap on the rinse aid compartmenthas not been shut correctly.Make sure the cap of the rinse aid dispenser is closed.The lter is soiled or clogged.Clean the lter assembly (see CARE AND MAINTENANCE).There is no salt.Fill the salt reservoir (see FILLING THE SALT RESERVOIR).CONTACTING AFTER-SALES SERVICEIMPORTANT TO BE READ AND OBSERVEDBefore using the appliance, read these safety instructions. Keep them nearby for future reference. These instructions and the appliance itself provide important safety warnings, to be observed at all times. The manufacturer declines any liability for failure to observe these safety instructions, for inappropriate use of the appliance or incorrect setting of controls.Very young children (0-3 years) should be kept away from the appliance. Young children (3-8 years) should be kept away from the appliance unless continuously supervised. Children from 8 years old and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.CAUTION: the appliance is not intended to be operated by means of an external switching device, such as a timer, or separate remote controlled system.This appliance is intended to be used in household and similar applications such as: staff kitchen areas in shops, offices and other working environments; farm houses; by clients in hotels, motels, bed & breakfast and other residential environments.The maximum number of place settings is shown in the product sheet.The door should not be left in the open position - risk of tripping. The open appliance door can only support the weight of the loaded rack when pulled out. Do not rest objects on the door or sit or stand on it.WARNING:Dishwasher detergents are strongly alkaline. They can be extremely dangerous if swallowed. Avoid contact with the skin and eyes and keep children away from the dishwasher when the door is open. Check that the detergent receptacle is empty after completion of the wash cycle.WARNING: Knives and other utensils with sharp points must be loaded in the basket with their points down or placed in a horizontal position - risk of cuts.This appliance is not for professional use. Do not use the appliance outdoors. Do not store explosive or flammable substances (e.g. gasoline or aerosol cans) inside or near the appliance - risk of fire. The appliance must be used only to wash domestic dishes in accordance with the instructions in this manual. The water in the appliance is not potable. Use only detergent and rinse additives designed for an automatic dishwasher. When adding a water softener (salt), run one cycleThe appliance must be handled and installed by two or more persons - risk of injury. Use protective gloves to unpack and install - risk of cuts. Connect the dishwasher to the water mains using only new hose sets. The old hose sets should not be reused. All hoses must be securely clamped to prevent them coming loose during operation. All local waterboard regulations must be complied with. Water supply pressure 0.05 - 1.0 MPa. The appliance must be placed against the wall or built into furniture to limit the access to its rearside. For dishwashers having ventilation openings in the base, the openings must not be obstructed by a carpet.Installation, including water supply (if any) and electrical connections, and repairs must be carried out by a qualified technician. Do not repair or replace any part of the appliance unless specifically stated in the user manual. Keep children away from the installation site. After unpacking the appliance, make sure that it has not been damaged during transport. In the event of problems, contact the dealer or your nearest After-sales Service. Once installed, packaging waste (plastic, styrofoam parts etc.) must be stored out of reach of children - risk of suffocation. The appliance must be disconnected from the power supply before any installation operation - risk of electrical shock. During installation, make sure the appliance does not damage the power cable - risk of fire or electrical shock. Only activate the appliance when the installation has been completed.If installing the dishwasher at the end of a row of units making the side panel accessible, the hinge area must be covered to avoid risk of injury. The inlet water temperature depends on the dishwasher model. If the installed inlet hose is marked "25°C Max”, the maximum allowed water temperature is 25°C. For all other models the maximum allowed water temperature is 60°C.Do not cut hoses and, in the case of appliances fitted with a waterstop system, do not immerse the plastic casing containing the inlet hose in water. If hoses are not long enough, contact your local dealer. Make sure the inlet and drain hoses are kink-free and are not crushed. Before using the appliance for the first time, check the water inlet and drain hose for leaks. Make sure that the four feet are stable and resting on the floor, adjusting them as required, and check that the dishwasher is perfectly levelled using a spirit level. immediately with the machine empty, to avoid corrosion damage to internal parts. Store the detergent, rinse aid and salt out of reach of children. Shut off the water supply and unplug or disconnect the power before servicing and maintenance. Disconnect the appliance in the event of any malfunction.PERMITTED USE INSTALLATIONENHEALTH & SAFETY GUIDE。

HBC26D553 说明书

HBC26D553 说明书

[zh] 说明手册 (2)*9000605703*9000605703÷目录安全预防措施 (3)安全注意事项 (3)损坏原因 (3)您的新电器 (4)控制面板 (4)加热类型 (4)烹饪箱 (5)附件 (5)自动校准 (5)在第一次使用电器之前 (6)设置时钟和语言 (6)设置水的硬度范围 (6)首次使用之前 (6)使用附件前先清洁附件 (6)操作电器 (7)加注水箱 (7)开启电器 (7)关断电器 (8)在每次使用之后 (8)推荐设置 (8)时间设置选项 (8)设置定时器 (8)设置烹饪时间 (9)设置延时结束时间 (9)设置时钟 (9)自动程序 (10)设置程序 (10)程序说明 (10)程序表 (11)存储器 (14)保存至存储器功能 (14)启动存储器功能 (14)儿童锁 (14)激活儿童锁 (14)取消激活儿童锁 (14)基本设置 (14)保养和清洁 (15)清洁剂 (15)清洁辅助程序 (16)除垢 (17)拆卸和安装电器门 (18)清洁门面板 (18)清洁导轨 (18)故障检修 (19)更换烹饪箱灯泡 (20)更换门封 (20)售后服务 (21)E 编号和 FD 编号 (21)环境保护 (21)环境保护 (21)节能技巧.....................................................................................21设定表和使用技巧. (21)附件 (21)烹饪容器 (21)烹饪时间和数量 (21)均匀分布食物 (21)压力敏感食物 (21)套餐烹饪 (22)蔬菜 (22)配菜和豆类 (22)家禽和肉 (23)鱼 (24)蔬菜汤,其他 (24)甜食、蜜饯 (24)重新加热食物 (25)解冻 (25)发酵生面团 (25)榨汁 (26)腌渍 (26)冷冻产品 (27)关于产品、附件、更换部件以及服务的更多信息请参见 和在线商店 2ƽ 安全预防措施请仔细阅读使用说明。

BCU操作说明书,中文翻译版

BCU操作说明书,中文翻译版

BCU操作说明书,中文翻译版烧嘴控制单元—BCU 4##操作说明书●请阅读并保留在一个安全的地方符号的解释:●,①, ②, ③... =功能→ =说明这些操作说明里的所有工作的开始只能由被授权的专门人员来完成!注意:不正确的安装、调节、修改、操作或维护可能会造成材料的损坏。

用之前请阅读本说明书,这个单元必须按照生效的规定来安装。

内容符合标准声明、测试、安装、电缆的选择与安装、技术数据、接线、调节、鉴定、调试、高温下的操作、检查功能、手动操作、出现故障时的处理、读取火焰的信号和参数设置、附件符合标准声明我们生产商在此声明,标有产品ID号CE-0063BO1064的产品:BCU400,460,465,480,遵守以下指令的基本要求:—90/396/EEC与 EN 298相一致—98/37/EC与EN 746的相关截面相一致—73/23/EEC与相关的标准相一致—89/336/EEC与涉及到辐射的相关标准相一致现场总线的接口应按照EN 50170-2的要求,,相关产品应符合由被通告人0063所做的定型试验,综合质量的保证是由一个依据DIN EN ISO 9001的质量体系认证来担保的,DIN EN ISO 9001是按照附件2第3页的指令90/396/EEC.Elster GmbHOsnabrückCAS和FM认证加拿大标准协会类别:3335-01 和 3335-81,“系统(气体)—自动点火和部件”,FMRC:7611“燃烧保护设施和火焰感应系统”,应用程序的设计依据NFPA 85 和NFPA 86。

BCU带有完整的点火变压器,在连续的操作中用来点燃和检测燃气烧嘴,BCU 440–480的监测是由电离电极来执行的,BCU 460–480由紫外线传感器来执行。

带有UVS式UV传感器的BCU只能在断续操作状态下使用,这就意味着操作必须在24小时内间断一次。

带有UVD 1式的UV传感器的BCU只适应于BCU 460..U 和BCU 480..U,这种BCU也适用于连续的操作,连接的细节请看UVD操作说明书。

DS26LS32AC中文资料

DS26LS32AC中文资料

DS26LS32AC中文资料TL F 5255DS26LS32C DS26LS32M DS26LS32AC DS26LS33C DS26LS33M DS26LS33AC Quad Differential Line ReceiversJanuary1996 DS26LS32C DS26LS32M DS26LS32ACDS26LS33CDS26LS33M DS26LS33AC Quad Differential Line Receivers General DescriptionThe DS26LS32and DS26LS32A are quad differential linereceivers designed to meet the RS-422 RS-423and Feder- al Standards1020and1030for balanced and unbalanceddigital data transmissionThe DS26LS32and DS26LS32A have an input sensitivity of 200mV over the input voltage range of g7V and theDS26LS33and DS26LS33A have an input sensitivity of500mV over the input voltage range of g15VBoth the DS26LS32A and DS26LS33A differ in functionfrom the popular DS26LS32and DS26LS33in that inputpull-up and pull-down resistors are included which prevent output oscillation on unused channelsEach version provides an enable and disable function com- mon to all four receivers and features TRI-STATE outputswith8mA sink capability Constructed using low powerSchottky processing these devices are available over thefull military and commerical operating temperature ranges FeaturesY High differential or common-mode input voltage ranges of g7V on the DS26LS32and DS26LS32A and g15Von the DS26LS33and DS26LS33AY g0 2V sensitivity over the input voltage range on theDS26LS32and DS26LS32A g0 5V sensitivity on theDS26LS33and DS26LS33AY DS26LS32and DS26LS32A meet all requirements ofRS-422and RS-423Y6k minimum input impedanceY100mV input hysteresis on the DS26LS32andDS26LS32A 200mV on the DS26LS33andDS26LS33AY Operation from a single5V supplyY TRI-STATE outputs with choice of complementary out-put enables for receiving directly onto a data bus Logic DiagramTL F 5255–1 Connection DiagramDual-In-Line PackageTL F 5255–2Top ViewTruth TableENABLE ENABLE Input Output01X Hi-ZSee V ID t V TH(Max)1Note Below VID s V TH(Min)0HI-Z e TRI-STATENote Input conditions may be any combination not defined for ENABLEand ENABLEOrder Number DS26LS32CM DS26LS32CNDS26LS32MJ DS26LS32ACM DS26LS32ACNDS26LS33CN DS26LS33MJ or DS26LS33ACNSee NS Package Number J16A M16A or N16AFor Complete Military883SpecificationsSee RETS Data SheetOrder Number DS26LS32MJ 883 DS26LS32MW 883DS26LS33MJ 883 DS26LS33MW 883See NS Package Number J16A or W16A TRI-STATE is aregistered trademark of National Semiconductor Corporation C1996National Semiconductor Corporation RRD-B30M36 Printed in U S A http www national comAbsolute Maximum Ratings(Note1)If Military Aerospace specified devices are required please contact the National Semiconductor Sales Office Distributors for availability and specifications Supply Voltage7V Common-Mode Range g25V Differential Input Voltage g25V Enable Voltage7V Output Sink Current50mA Maximum Power Dissipation at25 C Cavity Package1433mW Molded Dip Package1362mW SO Package DS26LS321002mWDS26LS32A1051mW Derate cavity package9 6mW C above25 C derate molded DIP package 10 9mW C above25 C Derate SO Package8 01mW C for DS26LS328 41mW C for DS26LS32A Storage T emperature Range b65C to a165 C Lead Temperature(Soldering 4seconds)260 C Operating ConditionsMin Max Units Supply Voltage (V CC)DS26LS32M DS26LS33M4 55 5V (MIL)DS26LS32C DS26LS33C4 755 25V DS26LS32AC DS26LS33AC (COML)Temperature (T A)DS26LS32M DS26LS33M b55a125 C (MIL)DS26LS32C DS26LS33C0a70 C DS26LS32AC DS26LS33AC(COML)Electrical Characteristics over the operating temperature range unless otherwise specified(Notes2 3and4) Symbol Parameter Conditions Min Typ Max UnitsV TH Differential Input V OUT e V OH DS26LS32 DS26LS32A b7V s V CM s a7V b0 2g0 070 2V Voltage or V OL DS26LS33DS26LS33A b15V s VCM a15V b0 5g0 140 5V R IN Input Resistance b15V s V CM s a15V(One Input AC GND)6 08 5k X I IN Input Current(Under V IN e15V Other Input b15V s V IN s a15V2 3mATest)VIN e b15V Other Input b15V s V IN s a15V b2 8mA V OH Output High Voltage V CC e MIN D V IN e1V Commercial2 74 2V V ENABLE e0 8V I OH e b440m A Military2 54 2V V OL Output Low Voltage V CC e Min D V IN e b1V I OL e4mA0 4V V ENABLE e0 8V IOL e8mA0 45V V IL Enable Low Voltage0 8V V IH Enable High Voltage2 0VV I Enable Clamp V CC e Min I IN e b18mAb1 5V VoltageI O OFF-State(High V CC e Max V O e2 4V20m AImpedance)OutputV O e0 4V b20m A CurrentI IL Enable Low Current V IN e0 4V b0 36mA I IH Enable High Current V IN e2 7V20m AI SC Output Short-Circuit V O e0V V CC e Max D V IN e1Vb15b85mA CurrentI CC Power Supply V CC e Max All V IN e GND DS26LS32 DS26LS32A5270mACurrent Outputs Disabled DS26LS33 DS26LS33A5780mA I I Input High Current V IN e5 5V100m A V HYST Input Hysteresis T A e25 C V CC e5V DS26LS32 DS26S32A100mVV CM e0V DS26LS33 DS26LS33A200mVNote1 ‘‘Absolute Maximum Ratings’’are those values beyond which the safety of the device cannot be guaranteed They are not meant to imply that the device should be operatedat these limits The table of‘‘Electrical Characteristics’’provides conditions for actual device operationNote2 All currents into device pins are shown as positive all currents out of device pins are shown as negative all voltages are referenced to ground unless otherwise specified All values shown as max or min are so classified on absolute value basis Note3 All typical values are V CC e5V T A e25 CNote4 Only one output at a time should be shortedhttp www national com2Switching Characteristics V CC e 5V T A e 25 CSymbol Parameter Conditions DS26LS32 DS26LS33DS26LS32A DS26LS33A UnitsMinTyp Max MinTyp Max t PLH Input to Output C L e 15pF 17252335ns t PHL 17252335ns t LZ ENABLE to Output C L e 5pF 20301530ns t HZ 15222025ns t ZL ENABLE to OutputC L e 15pF15221422ns t ZH15221522ns AC Test Circuit and Switching Time WaveformsLoad Test Circuit for TRI-STATE OutputsTL F 5255–3Propagation Delay (Notes 1and 3)TL F 5255–4Note 1 Diagram shown for ENABLE lowNote 2 S1and S2of load circuit are closed except whereshownNote 3 Pulse generator for all pulses Rate e 1 0MHz Z O e 50X t r s 6ns t f s 6 0nsEnable and Disable Times (Notes 2and 3)TL F 5255–5Typical ApplicationsTwo-Wire Balanced Interface RS-422TL F 5255–6Single Wire with Driver Ground Reference RS-423TL F 5255–7http www national com3Physical Dimensions inches(millimeters)Order Number DS26LS32MJ DS26LS33MJ DS26LS32MJ 883or DS26LS33MJ 883NS Package Number J16ASmall Outline Package(M)Order Number DS26LS32CM or DS26LS32ACMNS Package Number M16Ahttp www national com4Physical Dimensions inches(millimeters)(Continued)Order Number DS26LS32CN DS26LS32ACN DS26LS33CN or DS26LS33ACNNS Package Number N16A5http www national comD S 26L S 32C D S 26L S 32M D S 26L S 32A C D S 26L S 33C D S 26L S 33M D S 26L S 33A C Q u a d D i f f e r e n t i a l L i n e R e c e i v e r sPhysical Dimensions inches (millimeters)(Continued)16Lead Ceramic Flatpak (W)Order Number DS26LS32MW 883or DS26LS33MW 883NS Package Number W16ALIFE SUPPORT POLICYNATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION Asused herein 1 Life support devices or systems are devices or 2 A critical component is any component of a life systems which (a)are intended for surgical implant support device or system whose failure to perform can into the body or (b)support or sustain life and whose be reasonably expected to cause the failure of the life failure to perform when properly used in accordance support device or system or to affect its safety or with instructions for use provided in the labeling can effectivenessbe reasonably expected to result in a significant injury to the userNational Semiconductor National Semiconductor National Semiconductor National Semiconductor Corporation EuropeHong Kong LtdJapan Ltd1111West Bardin RoadFax a 49(0)180-530858613th Floor Straight Block Tel 81-043-299-2308。

bc26的用法 -回复

bc26的用法 -回复

bc26的用法-回复BC26是一种常见的建筑材料,被广泛应用于建筑工程中。

它有很多不同的用途和用法,本文将详细介绍BC26的用法,以及如何正确地使用它。

首先,让我们了解一下BC26是什么。

BC26是一种混凝土材料,有着高强度和耐久性的特点。

它由水泥、骨料和适量的添加剂组成,通过混合而成。

BC26的命名中的“26”代表了它的强度等级,表示其抗压强度为26兆帕(MPa)。

BC26的主要用途之一是用于混凝土结构的建造。

它可以用于浇筑楼板、柱、梁、墙体等各种混凝土构件。

BC26的高强度使得它成为一种理想的结构材料,能够承受较大的荷载和压力。

在施工过程中,BC26还可以与钢筋结合使用,增强混凝土的抗拉能力,提高整体结构的稳定性。

在使用BC26之前,有几个重要的步骤需要遵循。

首先,需要根据工程需求制定合理的配合比。

配合比是指混凝土中各种原材料的比例关系。

一般来说,合理的配合比能够保证混凝土的强度和工作性能。

因此,在施工前,需要进行实验室测试和材料筛选,确定最佳的配合比。

接下来,需要准备好施工现场。

施工现场需要具备平整、稳定和安全的条件。

需要清理现场,并搭建脚手架和安全网,确保施工过程中的安全。

此外,还应准备好施工所需的工具和设备,如搅拌机、输送泵、输送管道等。

然后,需要进行BC26混凝土的搅拌和浇筑工作。

搅拌可以手动进行,也可以使用机械设备进行。

搅拌时,应根据配合比将水泥、骨料和添加剂按照一定比例进行混合,并逐渐加入适量的清水。

搅拌时间通常为2-3分钟,直到混合均匀。

在搅拌完成后,需要迅速进行混凝土的浇筑工作。

浇筑时,应尽量避免混凝土的堆积和空隙,以保证整体结构的均匀性和稳定性。

浇筑过程中还应及时使用振动器进行振动,以排除混凝土中的空气和水泥浆,进一步提高混凝土的强度和密实性。

BC26的浇筑完成后,需要进行养护工作。

养护是指通过适当的方法和措施,帮助混凝土逐渐获得足够的强度和耐久性。

养护期间,应保持混凝土表面湿润,可使用喷水或铺设湿润的麻布等方法。

Versadrive SC-26 发射器管理系统说明书

Versadrive SC-26 发射器管理系统说明书
16.Do not install this apparatus in a confined space such as a book case or similar unit. Good ventilation should be maintained around the apparatus. Any vents, air-inlets or fans should not be obstructed by objects such as paper, table-cloths, curtains etc.
18.WARNING: The mains plug/appliance coupler is used as a disconnect device, the disconnect device shall remain readily operable.
ATTENTION: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
Versadrive SC-26 Speaker Management System OPERATING MANUAL AND USER GUIDE

Table Of Contents
Table Of Contents...................................................................................... 1 Important Warnings & Safety Instructions.................................................. 2 Editing Audio Settings................................................................................ 4 Editing System Settings............................................................................. 5 PC Software Operation.............................................................................. 6 Specifications............................................................................................. 9 Warranty................................................................................................... 10

BCV46中文资料

BCV46中文资料

This data sheet contains target or goal specifications for product development. This data sheet contains preliminary data; supplementary data may be published later. This data sheet contains final product specifications.


4000 −
BCV46
2000 −
DC current gain BCV26
IC = −10 mA; VCE = −5 V; (see Fig.2) 10000 −
BCV46
4000 −
DC current gain BCV26
IC = −100 mA; VCE = −5 V; (see Fig.2) 20000 −
e1
HE
Lp
Q
v
w
mm
1.1 0.9
0.1
0.48 0.38
0.15 0.09
3.0 2.8
1.4 1.2
1.9
0.95
2.5 2.1
0.45 0.55 0.15 0.45
0.2
0.1
OUTLINE
VERSION
IEC
SOT23
1999 Apr 08
REFERENCES
JEDEC
EIAJ
5
EUROPEAN PROJECTION
Application information
Where application information is given, it is advisory and does not form part of the specification.

浙江版CSC-241C数字式所(厂)用变保护测控装置说明书V1.00

浙江版CSC-241C数字式所(厂)用变保护测控装置说明书V1.00
司联系,我们将为您提供相应的服务。 技术支持电话:010-62986668 传真:010-62981900
重要提示
感谢您使用北京四方继保自动化股份有限公司的产品。为了安全、正 确、高效地使用本装置,请您务必注意以下重要提示:
1) 本说明书仅适用于浙江地区双保护 CT 的 CSC-241C 数字式厂(所) 用变保护测控装置。
3 装置硬件 ................................................................................................... 6
3.1 装置结构 ................................................................................................................................... 6 3.2 装置功能组件概述.................................................................................................................... 6 3.3 交流插件(AC)........................................................................................................................ 7 3.4 CPU 插件(CPU)....................................................................................................................... 7 3.5 逻辑插件(LOG)...................................................................................................................... 7 3.6 开出插件(DO)........................................................................................................................ 7 3.7 通信插件(COM)...................................................................................................................... 8 3.8 人机接口(MMI)...................................................................................................................... 8 3.9 电源插件(POW)...................................................................................................................... 8 3.10 插件布置 ................................................................................................................................... 8

F8X26 系列路由器使用说明书

F8X26 系列路由器使用说明书

F8X26系列路由器使用说明书文档版本密级V2.0.0产品名称:F8X26共94页F8X26系列路由器使用说明书厦门四信通信科技有限公司Add:厦门市集美区软件园三期诚毅大街370号A06栋11层客户热线:400-8838-199电话:+86-592-6300320传真:+86-592-5912735网址文档修订记录日期版本说明作者2016-3-24V1.0.0新版ZigBee路由器ZZF 2017-9-23V2.0.0更新地址Faine著作权声明本文档所载的所有材料或内容受版权法的保护,所有版权由厦门四信通信科技有限公司拥有,但注明引用其他方的内容除外。

未经四信公司书面许可,任何人不得将本文档上的任何内容以任何方式进行复制、经销、翻印、连接、传送等任何商业目的的使用,但对于非商业目的的、个人使用的下载或打印(条件是不得修改,且须保留该材料中的版权说明或其他所有权的说明)除外。

商标声明Four-Faith 、四信、、、均系厦门四信通信科技有限公司注册商标,未经事先书面许可,任何人不得以任何方式使用四信名称及四信的商标、标记。

目录目录 (5)第一章产品简介 (7)1.1产品概述 (7)1.2产品特点 (7)1.3工作原理框图 (9)1.4产品规格 (9)第二章安装 (14)2.1概述 (14)2.2装箱清单 (14)2.3安装与电缆连接 (14)2.4电源说明 (18)2.5指示灯说明 (19)2.6复位按钮说明 (19)第三章参数配置 (20)3.1配置连接图 (20)3.2登录到配置页面 (20)3.2.1PC机IP地址设置(两种方式) (20)3.2.2登入到配置页面 (21)3.3管理和配置 (23)3.3.1设置 (23)3.3.1.1基本设置 (23)3.3.1.2动态DNS(DDNS) (28)3.3.1.3MAC地址克隆 (29)3.3.1.4高级路由 (30)3.3.1.5VLANs (31)3.3.1.6网络 (32)3.3.2无线 (35)3.3.2.1基本配置 (35)3.3.2.2无线安全 (37)3.3.3服务 (40)3.3.3.1服务 (40)3.3.4VPN (42)3.3.4.1PPTP (42)3.3.4.2L2TP (44)3.3.4.3OPENVPN (45)3.3.4.4IPSEC (50)3.3.4.5GRE (52)3.3.5安全 (54)3.3.5.1防火墙 (54)3.3.6访问限制 (56)3.3.6.1WAN访问 (56)3.3.6.2URL过滤 (59)3.3.6.3数据流过滤 (59)3.3.7NAT (60)3.3.7.1端口转发 (60)3.3.7.2端口范围转发 (61)3.3.7.3DMZ (62)3.3.8QoS设置 (62)3.3.8.1基本 (62)3.3.8.2分类 (63)3.3.9应用 (64)3.3.9.1串口应用 (64)3.3.9.2ZigBee应用 (66)3.3.10管理 (68)3.3.10.1管理 (68)3.3.10.2保持活动 (70)3.3.10.3命令 (70)3.3.10.4出厂默认 (71)3.3.10.5固件升级 (72)3.3.10.6备份 (72)3.3.11状态 (73)3.3.11.1路由器 (73)3.3.11.2WAN (75)3.3.11.3LAN (78)3.3.11.4无线 (80)3.3.11.5宽带 (82)3.3.11.6系统信息 (83)附录一超级终端使用 (86)附录二API模式 (88)4.4.3.1发送数据命令 (88)4.4.3.2接收到数据指示 (89)4.4.3.3设置当前工作模式 (89)4.4.3.4OTA端口数据采集 (90)4.4.3.5OTA端口输出设置(数字输出模式) (91)4.4.3.6OTA IEEE地址查询 (91)4.4.3.7OTA网络地址查询 (92)4.4.3.8OTA整个网络查询 (93)第一章产品简介1.1产品概述F8X26系列ROUTER是一种物联网无线通信路由器,利用公用无线网络为用户提供无线长距离数据传输功能,同时支持ZigBee数据通信功能。

BYV26C-TR;中文规格书,Datasheet资料

BYV26C-TR;中文规格书,Datasheet资料

Ultra Fast Avalanche Sinterglass DiodeBYV26A, BYV26B, BYV26C, BYV26D, BYV26EVishay SemiconductorsDocument Number: 86040For technical questions within your region, please contact one of the following:MECHANICAL DATACase: SOD-57Terminals: plated axial leads, solderable per MIL-STD-750,method 2026Polarity: color band denotes cathode end Mounting position: any Weight: approx. 369 mgFEATURES•Glass passivated junction •Hermetically sealed package •Very low switching losses •Low reverse current •High reverse voltage•Compliant to RoHS directive 2002/95/EC and in accordance to WEEE 2002/96/EC•Halogen-free according to IEC 61249-2-21 definitionAPPLICATIONS•Switched mode power supplies •High-frequency inverter circuits949539PARTS TABLEPART TYPE DIFFERENTIATION PACKAGE BYV26A V R = 200 V; I FAV = 1 A SOD-57BYV26B V R = 400 V; I FAV = 1 A SOD-57BYV26C V R = 600 V; I FAV = 1 A SOD-57BYV26D V R = 800 V; I FAV = 1 A SOD-57BYV26EV R = 1000 V; I FAV = 1 ASOD-57ABSOLUTE MAXIMUM RATINGS (T amb = 25°C, unless otherwise specified)PARAMETERTEST CONDITIONPART SYMBOL VALUE UNIT Reverse voltage = repetitive peak reverse voltageSee electrical characteristicsBYV26AV R = V RRM 200V BYV26BV R = V RRM 400V BYV26C V R = V RRM 600V BYV26D V R = V RRM 800V BYV26EV R = V RRM1000V Peak forward surge current t p = 10 ms, half sine waveI FSM 30A Average forward currentI FAV 1A Non repetitive reverse avalanche energyI (BR)R = 1 A, inductive load E R 10mJ Junction and storage temperature rangeT j = T stg- 55 to + 175°CMAXIMUM THERMAL RESISTANCE (T amb = 25°C, unless otherwise specified)PARAMETER TEST CONDITION SYMBOL VALUE UNIT Junction ambientl = 10 mm, T L = constantR thJA45K/WBYV26A, BYV26B, BYV26C, BYV26D, BYV26EVishay SemiconductorsUltra Fast Avalanche SinterglassDiode For technical questions within your region, please contact one of the following:Document Number: 86040TYPICAL CHARACTERISTICS (T amb = 25 °C, unless otherwise specified)Fig. 1 - Max. Reverse Power Dissipation vs. Junction Temperature Fig. 2 - Max. Reverse Current vs. Junction Temperature Fig. 3 - Max. Average Forward Current vs. Ambient TemperatureFig. 4 - Max. Reverse Current vs. Junction TemperatureELECTRICAL CHARACTERISTICS (T amb = 25°C, unless otherwise specified)PARAMETER TEST CONDITIONPARTSYMBOLMIN.TYP.MAX.UNIT Forward voltage I F = 1 A V F -- 2.5V I F = 1 A, T j = 175 °CV F -- 1.3V Reverse currentV R = V RRMI R --5μA V R = V RRM , T j = 150°CI R --100μA Reverse breakdown voltageI R = 100 μABYV26A V (BR)R 300--V BYV26BV (BR)R 500--V BYV26C V (BR)R 700--V BYV26D V (BR)R 900--V BYV26E V (BR)R 1100--V Reverse recovery timeI F = 0.5 A, I R = 1 A, i R = 0.25 ABYV26A t rr --30ns BYV26Bt rr --30ns BYV26C t rr --30ns BYV26D t rr --75ns BYV26E t rr--75nsBYV26A, BYV26B, BYV26C, BYV26D, BYV26EUltra Fast Avalanche SinterglassDiodeVishay SemiconductorsDocument Number: 86040For technical questions within your region, please contact one of the following:Fig. 5 - Diode Capacitance vs. Reverse Voltage Fig. 6 - Diode Capacitance vs. Reverse VoltagePACKAGE DIMENSIONS in millimeters (inches): SOD-57Legal Disclaimer Notice VishayDisclaimerALL PRODU CT, PRODU CT SPECIFICATIONS AND DATA ARE SU BJECT TO CHANGE WITHOU T NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.Material Category PolicyVishay Intertechnology, Inc. hereb y certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant.Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.Revision: 12-Mar-121Document Number: 91000分销商库存信息: VISHAYBYV26C-TR。

MCC26资料

MCC26资料

419IXYS reserves the right to change limits, test conditions and dimensionsI TRMS =2x50 A I TAVM =2x32 A V RRM =800-1600 VV RSM V RRM Type V DSM V DRM V V Version 1 B 8 B Version 1 B8 B900 800MCC 26-08io1 B /io8 B MCD 26-08io1 B /io8 B 13001200MCC 26-12io1 B /io8 B MCD 26-12io1 B /io8 B 15001400MCC 26-14io1 B /io8 B MCD 26-14io1 B /io8 B 17001600MCC 26-16io1 B /io8 BMCD 26-16io1 B /io8 BData according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.Features•International standard package,JEDEC TO-240 AA•Direct copper bonded Al 2O 3 -ceramic base plate•Planar passivated chips •Isolation voltage 3600 V~•UL registered, E 72873•Gate-cathode twin pins for version 1B Applications•DC motor control•Softstart AC motor controller•Light, heat and temperature control Advantages•Space and weight savings•Simple mounting with two screws •Improved temperature and power cycling •Reduced protection circuitsSymbol ConditionsMaximum RatingsI TRMS , I FRMS T VJ = T VJM50A I TAVM , I FAVM T C = 75°C; 180° sine 32A T C = 85°C; 180° sine 27A I TSM , I FSMT VJ = 45°C;t = 10 ms (50 Hz), sine 520A V R = 0t = 8.3 ms (60 Hz), sine 560A T VJ = T VJM t = 10 ms (50 Hz), sine 460A V R = 0t = 8.3 ms (60 Hz), sine 500A ∫i 2dtT VJ = 45°C t = 10 ms (50 Hz), sine 1350A 2s V R = 0t = 8.3 ms (60 Hz), sine 1300A 2s T VJ = T VJM t = 10 ms (50 Hz), sine 1050A 2s V R = 0t = 8.3 ms (60 Hz), sine1030A 2s (di/dt)crT VJ = T VJM repetitive, I T = 45 A 150A/µsf =50 Hz, t P = 200 µs V D = 2/3 V DRM I G = 0.45 A non repetitive, I T = I TAVM 500A/µs di G /dt = 0.45 A/µs(dv/dt)cr T VJ = T VJM ;V DR = 2/3 V DRM1000V/µs R GK = ∞; method 1 (linear voltage rise)P GM T VJ = T VJM t P =30 µs 10W I T = I TAVMt P =300 µs5W P GAV 0.5W V RGM 10V T VJ -40...+125°C T VJM 125°C T stg -40...+125°C V ISOL 50/60 Hz, RMS t = 1 min 3000V~I ISOL ≤ 1 mAt = 1 s3600V~M d Mounting torque (M5)2.5-4.0/22-35Nm/lb.in.Terminal connection torque (M5) 2.5-4.0/22-35Nm/lb.in.WeightTypical including screws90gThyristor ModulesThyristor/Diode Modules6745321TO-240 AA31542MCDVersion 1 BMCCVersion 8 BMCDVersion 8 BMCCVersion 1 B419IXYS reserves the right to change limits, test conditions and dimensionsSymbol ConditionsCharacteristic ValuesI RRM , I DRM T VJ = T VJM ; V R = V RRM ; V D = V DRM 3mA V T , V F I T , I F = 80 A; T VJ = 25°C1.64V V T0For power-loss calculations only (T VJ = 125°C)0.85V r T 11.0m ΩV GT V D = 6 V;T VJ = 25°C 1.5V T VJ = -40°C 1.6V I GT V D = 6 V;T VJ = 25°C 100mA T VJ = -40°C 200mA V GD T VJ = T VJM ;V D = 2/3 V DRM0.2V I GD 10mA I L T VJ = 25°C; t P = 10 µs; V D = 6 V 450mA I G = 0.45 A; di G /dt = 0.45 A/µs I H T VJ = 25°C; V D = 6 V; R GK = ∞200mA t gd T VJ = 25°C; V D = 1/2 V DRM2µs I G = 0.45 A; di G /dt = 0.45 A/µst q T VJ = T VJM ; I T = 20 A, t P = 200 µs; -di/dt = 10 A/µs typ.150µs V R = 100 V; dv/dt = 20 V/µs; V D = 2/3 V DRM Q S T VJ = T VJM ; I T , I F = 25 A, -di/dt = 0.64 A/µs 50µC I RM 6AR thJC per thyristor/diode; DC current 0.88K/W per moduleother values 0.44K/W R thJK per thyristor/diode; DC current see Fig. 8/91.08K/W per module0.54K/W d S Creepage distance on surface 12.7mm d A Strike distance through air9.6mm aMaximum allowable acceleration50m/s 2Optional accessories for module-type MCC 26 version 1 BKeyed gate/cathode twin plugs with wire length = 350 mm, gate = yellow, cathode = redType ZY 200L (L = Left for pin pair 4/5)UL 758, style 1385,Type ZY 200R (R = right for pin pair 6/7)CSA class 5851, guide 460-1-1Dimensions in mm (1 mm = 0.0394")MCC Version 1 BMCC Version 8 BMCD Version 8 B10100100011010010001001011021031040.1110I GV GmAI Gµst gd V Fig. 1 Gate trigger characteristicsFig. 2 Gate trigger delay time419IXYS reserves the right to change limits, test conditions and dimensionsFig. 3Surge overload currentI TSM , I FSM : Crest value, t: durationFig. 4∫i 2dt versus time (1-10 ms)Fig. 4a Maximum forward currentat case temperature Fig. 5Power dissipation versus on-statecurrent and ambient temperature (per thyristor or diode)Fig. 6Three phase rectifier bridge:Power dissipation versus direct output current and ambient temperature419IXYS reserves the right to change limits, test conditions and dimensionsFig. 7Three phase AC-controller:Power dissipation versus RMS output current and ambient temperatureFig. 8Transient thermal impedancejunction to case (per thyristor or diode)Fig. 9Transient thermal impedancejunction to heatsink (per thyristor or diode)R thJC for various conduction angles d: d R thJC (K/W) DC 0.88180°0.92120°0.9560°0.9830°1.01Constants for Z thJCcalculation:i R thi (K/W)t i (s)10.0190.003120.0290.021630.8320.191R thJK for various conduction angles d: d R thJK (K/W) DC 1.08180° 1.12120° 1.1560° 1.1830°1.21Constants for Z thJK calculation:i R thi (K/W)t i (s)10.0190.003120.0290.021630.8320.19140.20.45。

BCV 62中文资料

BCV 62中文资料

ICBO
-
-
5 µA
DC current gain 1) IC = 0.1 mA, VCE = 5 V
hFE
100
-
--
DC current gain 1) IC = 2 mA, VCE = 5 V
hFE BCV 62A
BCV 62B
125 180 220 220 290 475
BCV 62C
420 520 800
150
°C
-65 ... 150
≤240
K/W
≤170
1) Package mounted on pcb 40mm x 40mm x 1.5mm / 6cm2 Cu
1
Oct-22-1999
元器件交易网
BCV 62
Electrical Characteristics at TA = 25°C, unless otherwise specified
VBEsat
-
700
-
-
850
-
Base-emitter voltage 1)
IC = 2 mA, VCE = 5 V IC = 10 mA, VCE = 5 V
VBE(ON) 600 650 750
-
-
820
1) Pulse test: t ≤ 300µs, D = 2%
2
Oct-22-1999
元器件交易网
h11e
-
4.5
- kΩ
h12e
-
2
- 10-4
h21e
100
-
900 -
h22e
-
30
- µS
1) Witout emitter resistor. Device mounted on alumina 15mm x 16.5mm x 0.7mm

BAT54C中文资料_数据手册_参数

BAT54C中文资料_数据手册_参数
Tj = 25 °C IF = 10 mA IF = 30 mA IF = 100 mA
Typ.
Max. Unit
1 µA
100
240
320
400 mV
500
900
Symbol
Table 5. Dynamic characteristics
Parameter
Test conditions
C Diode capacitance
current (typical values)
C(pF) 10
F=1MHz
VOSC=30mVRMS Tj=25°C
1.E+00 IFM(A) 1.E-01
Tj=100°C
1.E-02 1.E-03
Tj=50°C Tj=25°C Tj=-40 °C
VR(V) 1
1.E-04
VFM(V)
1
10
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
1
Characteristics
BAT54
Table 2. Absolute ratings (limiting values at Tj = 25 °C, unless otherwise specified)
Symbol
Parameter
Value
Unit
VRRM IF
IFSM Tstg Tj TL
0.148
Figure 12. SOD123 footprint dimensions in mm (inches)





6/15

德力西26dc电锤使用说明

德力西26dc电锤使用说明

德力西26dc电锤使用说明
德力西26DC电锤使用说明:
1. 准备工作:确保电锤已连接到电源,并确保电源是正常工作的。

2. 选择合适的配件:根据工作需求选择适合的钻头、凿子或其他配件,并将其安装到电锤上。

3. 调整速度:根据具体的工作需求,调整电锤的速度。

通常来说,较小的钻孔或轻度凿击时,使用较慢的速度;而较大的钻孔或重度凿击时,使用较快的速度。

4. 握紧电锤:握住电锤的手柄,并确保手柄紧固牢固,以确保安全操作。

5. 开始工作:将钻头或凿子置于工作表面,并应用适量的压力。

开始慢慢操作电锤,以钻孔或凿击所需的深度或程度。

6. 注意安全:在操作电锤时,请遵循以下安全注意事项:
- 穿戴适当的个人防护装备,如护目镜和手套。

- 避免长时间不间断使用电锤,以防止过热。

如果电锤过热,请停止使用并让其冷却。

- 在使用电锤时,始终保持稳定的姿势,并将电锤垂直于工
作表面。

- 在凿击前确认周围没有人员或其他物体,以免造成伤害。

- 当完成工作后,切勿将手指或其他物体放入电锤运动部件
附近,以防止受伤。

- 当不使用电锤时,请将其放置在安全位置,并避免不当触摸。

7. 清洁和维护:在每次使用后,清洁电锤,并将其存放在干燥、
清洁的地方。

定期检查电锤的配件和部件,并确保它们的运作正常。

如有任何故障或损坏,请立即停止使用电锤,并咨询专业人士进行修理或更换。

请注意,以上只是一般的使用说明。

在使用德力西26DC电锤之前,请务必阅读和理解附带的用户手册,并遵循制造商提供的具体使用和安全指南。

卡萨帝家用直流变频空调 CAS263VCA(A1)U1说明书

卡萨帝家用直流变频空调 CAS263VCA(A1)U1说明书

家用直流变频空调使用说明书使用前请仔细阅读说明书请妥善保存,以备参阅本产品只适合在中国大陆销售和使用CAS263VCA(A1)U1(SKFR-26GW/03VCA21AKU1)CAS353VCA(A1)U1(SKFR-35GW/03VCA21AKU1)CAS501VCA(A2)U1(SKFR-50GW/01VCA22AKU1)1FEEL THE NATUREFEEL THE NATURE 卡萨帝为了精确实现您的格调生活,对其家族每一类产品都赋予了专属的境界理念。

本产品为您带来的是冷暖舒适。

度量细微,洞察舒适2关于本产品的安全注意事项.........................................................3本产品的安装事项 (5)安装注意事项.......................................................................5随机附件..............................................................................5电力要求..............................................................................5室内外机安装图...................................................................6安装(按照室内机组安装图进行安装).................................6管路系统图...........................................................................6安装检查及试运转................................................................7室内机管路布置...................................................................7接线方法..............................................................................8室内外机接线.......................................................................8排空方法(R410A )..............................................................9本产品的外观及部件介绍.. (10)室内机................................................................................10室内机显示面板.................................................................10室外机................................................................................10遥控器.................................................................................11本产品的主要功能介绍 (12)1.遥控器的使用 (12)2.空气调节(PMV).............124.更改设定温度................................................135.风区、风速、风向设定...............................................14自清洁功能156....................................8.定时/WIFI功能 (17)9.静眠/辅热/应急运转功能..1810.试运转/停电补偿/灯光键/锁定功能19本产品的日常保养与维护 (20)空气过滤网的安装........................................20清洗机器............................................................................20换季收存............................................................................20有疑问?先看这儿!.. (21)(若对空调有疑问,请先按本章内容检查处理。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

ELECTRICAL CHARACTERISTICS (at Tamb = 25°C unless otherwise stated).
Collector-Base Breakdown Voltage Collector-Emitter Breakdown Voltage Emitter-Base Breakdown Voltage Collector Cut-Off Current V(BR)CBO V(BR)CEO V(BR)EBO ICBO BCV26 MIN. MAX. -40 -30 -10 CONDITIONS. IC=100µA IC=10mA * IE=10µA VCB = -30V VCB = -60V VCB=-30V,Tamb =150oC VCB=-60V,Tamb =150oC VEB=-4V IC=-100mA,IB=-0.1mA* IC=-100mA,IB=-0.1mA* IC=-100µΑ, VCE=-1V IC=-10mA, VCE=-5V* IC=-100mA, VCE=-5V* IC=-500mA, VCE=-5V* IC=-50mA, VCE=-5V f = 20MHz VCB=-10V, f=1MHz
BCV26 BCV46
EHale Waihona Puke BABSOLUTE MAXIMUM RATINGS.
PARAMETER Collector-Base Voltage Collector-Emitter Voltage Emitter-Base Voltage Peak Pulse Current Continuous Collector Current Base Current Power Dissipation at Tamb=25°C Operating and Storage Temperature Range PARAMETER SYMBOL BCV46 -80 -60 UNIT V V V mA mA mA mW °C
MHz pF
*Measured under pulsed conditions. Pulse width=300µs. Duty cycle ≤2% Spice parameter data is available upon request for these devices Periodic Sample Test Only. 3 - 21
SOT23 PNP SILICON PLANAR DARLINGTON TRANSISTORS
ISSUE 3 SEPTEMBER 1995 FEATURES * Low saturation voltage COMPLEMENTARY TYPE PARTMARKING DETAILS BCV26 - BCV27 BCV46 - BCV47 BCV26 - ZFD BCV46 - ZFE SYMBOL VCBO VCEO VEBO ICM IC IB Ptot Tj:Tstg BCV46 MIN. MAX. -80 -60 -10 -100 -10 IEBO VCE(sat) VBE(sat) -100 -1.0 -1.5 4K 10K 20K 4K 200 Typical 4.5 Typical -100 -10 -100 -1.0 -1.5 2K 4K 10K 2K 200 Typical 4.5 Typical BCV26 -40 -30 -10 -800 -500 -100 330 -55 to +150 UNIT V V V nA nA µA µA nA V V C
Emitter Base Cut-Off Current Collector-Emitter Saturation Voltage Base-Emitter Saturation Voltage
Static Forward Current hFE Transfer Ratio Transition Frequency Output Capacitance fT Cobo
相关文档