Short-time current resistance (Icw)
● limited to 0.5 s / rated value
kA
● limited to 1 s / rated value
kA
● limited to 2 s / rated value
kA
● limited to 3 s / rated value
2 2
system protection
500
Yes No Yes No
No No
without display
3WL1210-4BB34-4AN2 Page 2/4
05.01.2016
Changes preserved © Copyright Siemens AG
Short circuit
Operational short-circuit current breaking capacity (Ics)
05.01.2016
Changes preserved © Copyright Siemens AG
General Product Approval Shipping Approval
Declaration of Conformity
Test Certificates
spezielle Prüfbescheinigunge
Type of electrical connection / for main current circuit
Mechanical Design
Height
mm
Width
mm
Depth
mm
Mounting type
Environmental conditions Ambient temperature
3 2 15 000 B 3WL1210 15 000
1 000 1 000
IP20 LI
15
45
1 000
1 000
2 000
3WL1210-4BB34-4AN2 Page 1/4
05.01.2016
Changes preserved © Copyright Siemens AG
● of the instantaneous short-circuit release / Full- A scale value
kA
● at 500 V / rated value
kA
● at 690 V / rated value
kA
● at 1000/1150 V / rated value
kA
Connections Arrangement of electrical connectors / for main current circuit
Data sheet
Model product brand name Product designation Design of the operating mechanism Type of the driving mechanism
Type of the driving mechanism / motor drive Design of the overcurrent release
Product function Product function ● Ground fault protection ● Phase failure detection
Display and operation Display version
8 000
100 80 65 50
50 60 690 1 000 1 000 1 000 1 000 1 000 1 000
● during operation / minimum
°C
● during operation / maximum
°C
● during storage / minimum
°C
● during storage / maximum
°C
Certificates Equipment marking ● acc. to DIN EN 61346-2 ● acc. to DIN EN 81346-2
Dissipation Power loss [W]
● for rated value of the current / at AC / in hot
W
operating state / per pole
● maximum
W
Electricity来自Continuous current / rated value
kA
● at 500 V / rated value
kA
● at 690 V / rated value
kA
● at 1000/1150 V / Rated value
kA
Short-circuit current making capacity (Icm)
● at 415 V / rated value
n
sonstig
other
Umweltbestätigung
sonstig
Further information Industry Mall (Online ordering system)
https:///mall/en/WW/Catalog/Product/3WL12104BB344AN2
Suitability Suitability for use
Adjustable parameters
Adjustable response value current / of the current-
A
dependent overload release / initial value
Product details Product component ● Trip indicator ● Voltage trigger ● undervoltage release Product expansion / optional / motor drive
Voltage
Rated insulation voltage Ui
V
Insulation voltage / rated value
V
Protection class Protection class IP Protective function of the overcurrent release
A
Adjustable response value current
● of the current-dependent overload release /
A
Full-scale value
● of the instantaneous short-circuit release / initial A value
● at 415 V / rated value
kA
● at 500 V / rated value
kA
● at 690 V / rated value
kA
Maximum short-circuit current breaking capacity (Icu)
● at 415 V / rated value
100 100 85
100 100 85 50
220 220 187 105
Main connection top front/bottom double hole
busbar connection
507 460 369 fixed mounting
-20 70 -40 70
Q Q
3WL1210-4BB34-4AN2 Page 3/4
CAx-Online-Generator /cax
Tender specifications /tiplv
last modified:
11.12.2015
3WL1210-4BB34-4AN2 Page 4/4
A
● at 50 °C / rated value
A
● at 55 °C / rated value
A
● at 60 °C / rated value
A
● at 65 °C / rated value
A
● at 70 °C / rated value
A
Auxiliary circuit Number of NC contacts / for auxiliary contacts Number of NO contacts / for auxiliary contacts
General technical data Number of poles Size of the circuit-breaker Electrical endurance (switching cycles) / typical Usage category circuit-breaker / Design Mechanical service life (switching cycles) / typical
05.01.2016
Changes preserved © Copyright Siemens AG
3WL1210-4BB34-4AN2
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=1000A TO 690V, AC50/60HZ ICU=100KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
SENTRON ACB Pushbutton Manual/motorized operating mechanism with mechanical and electrical closing Yes ETU15B
kA
Main circuit Operating frequency
● 1 / rated value
Hz
● 2 / rated value
Hz
Operating voltage
● at AC / at 50/60 Hz / rated value
V
Operating current
● at 40 °C / rated value