电机电缆选配标准表格
(完整版)电缆选型表
Cu Al Cu Al Cu Al 1.5 6.824--29--61--2.57.231253830745948.1413249391007668.6524261501248710107255836418311916119573105832511492512.7120961351053672063513.91501151601254752525015.61801401951506183167017.42301752401858404039519.7280215285220113452812021.4325250325250138461815023.3375290365285168374218525.6430335415320208490424028.75103954803752696114530031.75854555454253355140940035.16905406254904246175850038.68006307105605092206063042.3920740810645636225102×1.510.519--25--1292×2.511.3262034271582×4.013.1352744352211362×6.014.1443556442741712×1016.7604676583781992×1618.88062100775192482×2522.3107831291007583142×3524.61311021571219784332×5023.115211818714512175102×7025.719414923317916136012×9529.323818527821521577502×12031.727521431824726589832×15035318246357276329611622×18538.6366284404314402714441753VV,VLV,ZC - VV,ZC - VLV 0.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量径mmVV,VLV,ZC - VV,ZC – VLV 0.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km标称截面mm2电缆参考外径mmCu Al Cu Al Cu Al 3×1.51117--22--154--3×2.511.9221729231941473×4.013.8292338302741993×6.014.9372947373482353×1017.6524065505293353×1619.9685385667404323×2523.791711108610585713×3526.11128713410413827053×5026.413310315912417608393×7029.8171131199153236410723×9533.8209162237184315814033×12036.7242188271210392116873×15040.2282218305236486821013×18545.6329255346269595225533×24051.7392304400310771332813×30056.14503484543511000441023×40074.8529410519403138273×4.0+1×2.514.4302438303112213×6.0+1×4.015.8383048384072703×10+1×6.018.5524066516083773×16+1×1021.1695486668765033×25+1×162593721118613047143×35+1×1627.11138813410417198563×50+1×2532.4141110163126210210183×70+1×3536.1180139203156280912893×95+1×5040.2221172242188376817033×120+1×7045.1258201276214474820633×150+1×7046.8298231310240570724903×185+1×9553.9343267349271712731063×240+1×12063.3408316406215910938913×300+1×15064.14793714623571188850833×400+1×18578.255341952740917064CuAlCuAlCuAlVV,VLV,ZC - VV,ZC – VLV 0.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km标称截面mm2电缆参考外径mm载流量载流量kg/km标称截面mm2电缆参考外径mm4×4.014.9302438303392394×6.016.1383048384362864×1019.3534166516694084×1621.8705486679535394×252694731128713747184×3528.71169013510518108994×5029.5139108161125231210824×7033177136202155310513814×9538.1217169240186417918364×12041.1254197274213518521994×15045.8294228309239641427204×18550.5337262346269790133654×24055.7401311403313102494×30063.4470364459355133654×40083.555743252941018307VV,ZC – VV 0.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km 3×4+2×2.515.330383513×6+2×41739484733×10+2×619.753666913×16+2×1022718710123×25+2×1626.89411015363×35+2×1628.911513218723×50+2×2534.214115725963×70+2×3538.818119735243×95+2×5044.422223447763×120+2×704925926661243×150+2×7053.729429871133×185+2×956034033890463×240+2×12067.5407395115583×300+2×15075.147444914389VV,ZC – VV 0.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km 5×416.231394035×617.53949520电缆参考外径mm 电缆参考外径mm 标称截面mm2标称截面mm25×102154678115×1623.8728711565×2528.59611117785×3531.311813423485×503714415931295×704218619943575×9549.122723559535×12053.626626972985×15059.330330289475×18566352343111445×24074.6420398143275×30082.6483452178234×4+1×2.515.731393754×6+1×417.339494944×10+1×620.453677494×16+1×1023.3718710804×25+1×1627.79511116574×35+1×1630.611613321004×50+1×2535.714215828434×70+1×3540.318319838924×95+1×5047.222423353724×120+1×7051.726226866764×150+1×7056.529730079754×185+1×9563346341100534×240+1×12070.9414398129244×300+1×15078.648145216016VV22, VLV22, ZC –VV22, ZC – VLV220.6/1kVCu Al Cu Al Cu Al 101370538062314250电缆参考外径mm标称截面mm2在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km16149371102813892872515.7118921311025273663516.91471121561216484265018.71761341911468135117020.522417023317910506129522.7275209279213137176512024.4319248319243163887315026.43682843592791959101918528.74253294093142395121524031.95043904753693333178330036.25794505404204091214540039.7685535620485497225732×4.016.3342741333883382×6.017.3433453424543792×1020584570545894592×1622776092717485432×2525.5104811229510297042×3527.812910014911612768252×5026.514611317113314878712×7030.3188144214165217813152×9534.2237184267207280016262×12036.5274213306238336518692×15040316245346268405922092×18543.8368286394306498426103×4.017292336284503753×6.018.1372945365384253×1020.8503860467455513×1623.1665179619836753×2526.990701058213448573×3529.31118612799170210253×5031.2129100148115234414243×7034.4165127185142301717253×9538.6206160221176391321583×12041.7242188261203474125073×15045.5281218296229579030233×18551328254337261701336143×24057.3386299389302893044983×30061.54453444413421135054473×4008151940350439115825VV22,VLV22,ZC –VV22,ZC – VLV220.6/1kVCu Al Cu Al Cu Al 3×4.0+1×2.517.630243729495405电缆参考外径mm 标称截面mm2在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km3×6.0+1×419.1383046376084713×10+1×621.8524064498346033×16+1×1025.57055846511437703×25+1×1628.2937210884160710173×35+1×1630.511388130101206011973×50+1×2537142110158123279517113×70+1×3540.7181139198152358120613×95+1×5045222172236183467626113×120+1×7049.7258201269209575130663×150+1×7052297230303235678835713×185+1×9559.5338262340264637143503×240+1×12069.54043133963071052353053×300+1×150704723654503491357267673×400+1×18584.2544422514398183984×4.018.2302437295294294×6.019.3383046376414914×1022.5534164499056444×16257155836512188044×2529.2947310884169010344×3533.511791132102247915684×5034.3140109157122296317334×7037.8178137196151383121074×9543.1219170234182503226894×12046.3255198268208610531194×15051294227301233747537814×18556.2333258338262907045344×24061.3397308393305116644×30069.3464359448347150184×40090.754842551540020202VV22,ZC – VV220.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km 5×4.019.431386065×6.020.739477395×1024.2556510725×162772851450电缆参考外径mm 标称截面mm25×2531.99610821435×3536.411913130985×5041.614515639925×7046.818719553565×9554.122523071385×12058.826326486165×15064.7301296104295×18571.6348335128175×24080.8409387152265×30089472439200624×4+1×2.510.931375724×6+1×420.539477104×10+1×623.6546510034×16+1×1026.5728413694×25+1×1631.19510820064×35+1×1635.211713028204×50+1×2540.31431553678VV22,ZC – VV220.6/1kV在空气中敷设近似埋地敷设近似电缆参考重量载流量载流量kg/km 4×70+1×3545.118419448504×95+1×5052.222422965114×120+1×7056.926026279484×150+1×7061.929629493874×185+1×9568.632933311652电缆参考外径mm 标称截面mm24×240+1×12077.140833814821 4×300+1×1508546944218148 3×4+2×2.518.53037543 3×6+2×420.23847686 3×10+2×622.95364935 3×16+2×102671841296 3×25+2×1630.2941071880 3×35+2×1633.51161292554 3×50+2×2538.81411543396 3×70+2×3543.61821934447 3×95+2×5049.42222295848 3×120+2×70552562617349 3×150+2×7059.12912918454 3×185+2×9565.633733110568 3×240+2×12073.740138513362 3×300+2×15081.546243916419。
电缆配置参考表
125A快速插件×1
KJ80/KJ90E
115/130
35 mm2×4根
(3×70+1×35)×1根
(3×35+1×16)×1根
35 mm2×4根
(3×50+1×16)×1根
BVR-50mm2×4根
125A快速插件×1
KJ100/KJ110E
144/159
50 mm2×4根
(3×95+1×50)×1根
(3×95+1×50)×2根
(3×95+1×50)×2根
150mm2×4根
(3×95+1×35)×2根
3×(70×2)+1×70(70mm2共7根)
接线铜排
★KJ300/KJ330E
433/476
3×(95×2)+1×50(95mm2共7根)
(3×120+1×70)×2根
(3×120+1×70)×2根
BVR-4mm2×4根
KM14/KM16E
20.2/23.1
6mm2×4根
(3×6+1×4)×1根
(3×6+1×4)×1根
6mm2×4根
(3×6+1×4)×1根
BVR-6mm2×4根
KM21/KM23E
30.4/33.2
10mm2×4根
(3×10+1×6)×1根
(3×10+1×6)×1根
10mm2×4根
58/64
10mm2×4根
(3×25+1×10)×1根
(3×16+1×10)×1根
10mm2×4根
(3×25+1×10)×1根
电动机控制元器件及电缆的选型
电动机控制元器件及电缆的选型如何根据电机的功率,考虑电机的额定电压,电流配线,选用断路器,热继电器口诀:三相二百二电机,千瓦三点五安培。
常用三百八电机,一个千瓦两安培。
低压六百六电机,千瓦一点二安培。
高压三千伏电机,四个千瓦一安培。
高压六千伏电机,八个千瓦一安培。
一台三相电机,除知道其额定电压以外,还必须知道其额定功率及额定电流,比如:一台三相异步电机,7.5KW,4极(常用一般有2、4、6级,级数不一样,其额定电流也有区别),其额定电路约为15A 。
1、断路器:一般选用其额定电流1.5-2.5倍,常用DZ47-60 32A,2、电线:根据电机的额定电流15A,选择合适载流量的电线,如果电机频繁启动,选相对粗一点的线,反之可以相对细一点,载流量有相关计算口决,这里我们选择4平方,3、交流接触器,根据电机功率选择合适大小就行,1.5-2.5倍,一般其选型手册上有型号,这里我们选择正泰CJX2--2510,还得注意辅助触点的匹配,不要到时候买回来辅助触点不够用。
4、热继电器,其整定电流都是可以调整,一般调至电机额定电流1-1.2倍。
断路器继电器电机配线电机如何配线?(1)多台电机配导线:把电机的总功率相加乘以2是它们的总电流。
(2)在线路50米以内导线截面是:总电流除4.(再适当放一点余量)(3)线路长越过50米外导线截面:总电流除3.(再适当放一点途量)(4)120平方以上的大电缆的电流密度要更低一些,断路器:(1)断路器选择:电机的额定电流乘以2.5倍,整定电流是电机的1.5倍就可以了,这样保证频繁启动,也保证短路动作灵敏。
热继电器?热继电器的整定值是电机额定电流是1.1倍。
交流接触器:交流接触器选择是电机流的2.5倍。
这样可以保证长期频繁工作。
怎样选用电线电缆及注意事项⒈电线电缆型号的选择选用电线电缆时,要考虑用途,敷设条件及安全性等;根据用途的不同,可选用电力电缆、架空绝缘电缆、控制电缆等;根据敷设条件的不同,可选用一般塑料绝缘电缆、钢带铠装电缆、钢丝铠装电缆、防腐电缆等;根据安全性要求,可选用阻燃电缆、无卤阻燃电缆、耐火电缆等。
电机电缆选配标准表
电缆规格线路压降电缆规格线路压降电缆规格线路压降YJVYJV2210.55~1.5KW 3.42921YJV-0.6/1KV 4X2.524X2.5 3.54X2.5 4.671416210DN202 2.2KW 52921YJV-0.6/1KV 4X2.5 2.94 3.674X4 3.451518290DN2533KW 6.82921YJV-0.6/1KV 4X2.544X4 3.354X4 4.691518290DN2544KW 8.82921YJV-0.6/1KV 4X2.5 3.884X4 4.344X6 4.071719380DN325 5.5KW 11.63829YJV-0.6/1KV 4X4 3.434X6 3.834X6 5.361719380DN3267.5KW 15.43829YJV-0.6/1KV 4X4 4.554X6 5.094X10 4.41922570DN32711KW 22.64937YJV-0.6/1KV 4X6 4.484X10 4.64X16 4.082325810DN40815KW 30.36852YJV-0.6/1KV 4X10 3.714X16 3.924X16 5.492325810DN40918.5KW 35.96852YJV-0.6/1KV 4X10 4.394X16 4.653X25+1X16 4.2726281210DN501022KW 42.59169YJV-0.6/1KV 4X16 3.34X16 5.53X25+1X16 5.0626281210DN501130KW 56.911687YJV-0.6/1KV 3X25+1X16 2.93X25+1X16 4.843X35+1X16 4.9628301530DN501237KW 70.4144109YJV-0.6/1KV 3X35+1X16 2.633X35+1X16 4.383X50+1X25 4.4430332010DN651345KW 84.2175133YJV-0.6/1KV 3X50+1X25 2.273X50+1X25 3.793X50+1X25 5.330332010DN651455KW 103224170YJV-0.6/1KV 3X70+1X35 2.073X70+1X35 3.453X70+1X35 4.8334372570DN651575KW 140271207YJV-0.6/1KV 3X95+1X50 2.213X95+1X50 3.683X95+1X50 5.1538403718DN801690KW 166314240YJV-0.6/1KV 3X120+1X70 2.173X120+1X70 3.613X120+1X70 5.0543.5444634DN8017110KW 203360277YJV-0.6/1KV 3X150+1X70 2.253X150+1X70 3.763X150+1X70 5.2647485940DN10018132KW 2422*2242*170YJV-0.6/1KV 2-(3X70+1X35) 2.432-(3X70+1X35) 4.052-(3X95+1X50) 4.453874362xDN8019160KW 2922*2242*207YJV-0.6/1KV 2-(3X95+1X50) 2.32-(3X95+1X50) 3.832-(3X95+1X50) 5.373874362xDN8020185KW 3382*3142*240YJV-0.6/1KV 2-(3X120+1X70) 2.212-(3X120+1X70) 3.682-(3X120+1X70) 5.1543.592682xDN8021200KW 3652*3142*240YJV-0.6/1KV 2-(3X120+1X70) 2.382-(3X120+1X70) 3.972-(3X120+1X70) 5.5643.592682xDN8022220KW 3972*3602*277YJV-0.6/1KV 2-(3X150+1X70) 2.22-(3X150+1X70) 3.672-(3X150+1X70) 5.1447118802xDN10023250KW 4602*4102*316YJV-0.6/1KV 2-(3X185+1X95)2.212-(3X185+1X95) 3.682-(3X185+1X95) 5.155253147602xDN10024280KW 5142*4832*374YJV-0.6/1KV 2-(3X240+1X120) 2.082-(3X240+1X120) 3.472-(3X240+1X120) 4.865859187562xDN12525315KW5722*4832*374YJV-0.6/1KV 2-(3X240+1X120 2.322-(3X240+1X120 3.862-(3X240+1X120 5.415818756电 缆 (250米范围内)电 缆 (150米范围内)YJV 电缆载流量(A )电缆型号序号电 缆 (350米范围内)穿管管径(mm)电缆外径VV电缆载流量(A )爆炸危险环境,电缆在空气中敷设,周围环境空气温度40℃(二、四、六极电机)YJV 重量(kg/km)电机电流(A)电机功率电缆规格线路压降电缆规格线路压降电缆规格线路压降YJVYJV22电 缆 (250米范围内)电 缆 (150米范围内)YJV 电缆载流量(A )电缆型号序号电 缆 (350米范围内)穿管管径(mm)电缆外径VV电缆载流量(A )YJV 重量(kg/km)电机电流(A)电机功率10.55~1.5KW 3.42921YJV-0.6/1KV 4X2.524X2.5 3.54X2.5 4.671416210DN202 2.2KW 52921YJV-0.6/1KV 4X2.5 2.944X2.5 3.674X4 3.451518290DN2533KW 6.82921YJV-0.6/1KV 4X2.544X4 3.354X4 4.691518290DN2544KW 8.82921YJV-0.6/1KV 4X2.5 3.884X4 4.344X6 4.071719380DN325 5.5KW 11.63829YJV-0.6/1KV 4X4 3.434X6 3.834X6 5.361719380DN3267.5KW 15.43829YJV-0.6/1KV 4X4 4.554X6 5.094X10 4.41922570DN32711KW 22.64937YJV-0.6/1KV 4X6 4.484X10 4.64X16 4.082325810DN40815KW 30.36852YJV-0.6/1KV 4X10 3.714X16 3.924X16 5.492325810DN40918.5KW 35.96852YJV-0.6/1KV 4X10 4.394X16 4.653X25+1X16 4.2726281210DN501022KW 42.59169YJV-0.6/1KV 4X16 3.34X16 5.53X25+1X16 5.0626281210DN501130KW 56.911687YJV-0.6/1KV 3X25+1X16 2.93X25+1X16 4.843X35+1X16 4.9628301530DN501237KW 70.411687YJV-0.6/1KV 3X25+1X16 3.593X35+1X16 4.383X50+1X25 4.4430332010DN651345KW 84.2144109YJV-0.6/1KV 3X35+1X16 3.143X50+1X25 3.793X50+1X25 5.330332010DN651455KW 103175133YJV-0.6/1KV 3X50+1X25 2.783X50+1X25 4.63X70+1X35 4.8334372570DN651575KW 140224170YJV-0.6/1KV 3X70+1X35 2.83X70+1X35 4.693X95+1X50 5.1538403718DN801690KW 166271207YJV-0.6/1KV 3X95+1X50 2.613X95+1X50 4.353X120+1X70 5.0543.5444634DN8017110KW 203314240YJV-0.6/1KV 3X120+1X70 2.653X120+1X70 4.423X150+1X70 5.2647485940DN10018132KW 242360277YJV-0.6/1KV 3X150+1X70 2.693X150+1X70 4.483X185+1X95 5.4238537380DN10019160KW 2922*2242*170YJV-0.6/1KV 2-(3X70+1X35) 2.722-(3X70+1X35) 4.532-(3X95+1X50) 5.373874362xDN8020185KW 3382*2712*207YJV-0.6/1KV 2-(3X95+1X50) 2.662-(3X95+1X50) 4.442-(3X120+1X70) 5.1543.592682xDN8021200KW 3652*2712*207YJV-0.6/1KV 2-(3X95+1X50) 2.872-(3X95+1X50) 4.792-(3X120+1X70) 5.5643.592682xDN8022220KW 3972*3142*240YJV-0.6/1KV 2-(3X120+1X70) 2.592-(3X120+1X70) 4.322-(3X150+1X70) 5.1447118802xDN10023250KW 4602*3602*277YJV-0.6/1KV 2-(3X150+1X70) 2.552-(3X150+1X70) 4.262-(3X185+1X95) 5.155253147602xDN10024280KW 5142*4102*316YJV-0.6/1KV 2-(3X185+1X95) 2.482-(3X240+1X120) 4.112-(3X240+1X120) 4.865859187562xDN12525315KW5722*4102*316YJV-0.6/1KV 2-(3X185+1X95 2.752-(3X240+1X120 4.572-(3X240+1X120 5.415818756普通环境,电缆在空气中敷设,周围环境空气温度40℃(二、四、六极电机)。
电缆选型标准
11-15KW
30.3
YJV3*10+1*6
16.60
53
M25*1.5(13-18mm)
18.5KW
35.9
YJV3*16+1*10
19.20
69
M32*1.5(18-25mm)
22-30KW
56.8
YJV3*25+1*16
22.40
89
M32*1.5(18-25mm)
37KW
69.8
YJV3*35+1*16
0.6/1kv非铠装不等截面交联聚乙烯绝缘、聚氯乙稀护套电力电缆(多芯结构)
3+1芯电缆截面积
电缆外直径
电缆允许载 流量(A)
电缆锁头大小及锁 头加紧范围
电机功率 ( KW)
电机额定电流 (A)
弱电电缆
RVVP 2*1.0
仪表电缆
RVSP 2*0.75
通讯电缆
动力电缆
YJVR4*1.5
10.00
15
24.60
109
M32*1.5(18-25mm)
45-55KW
102.5
YJV3*50+1*25
27.00
132
M40*1.5(22-32)
75KW
139.7
YJV3*70+1*35Fra bibliotek31.00
167
M40*1.5(22-32)
90KW
164.3
2*YJV3*50+1*25
2*27
264
2*M40*1.5(22-32)
500
2*YJV3*150+1*95
2*41.80
电机电缆防爆电缆选配标准
电机电流 (A)
YJV
VV
电缆载流 电缆载流量
量(A) (A)
电缆型号
电 缆 (150米范围内)
电缆规格
线路压降
电 缆 (250米范围内)
电缆规格
线路压降
电 缆 (350米范围内)
电缆规格
线路压降
电缆外径 YJV
爆炸危险环境,电缆在空气中敷设,周围环境空气温度40℃(二、四、六极电机)
3.4
29
21 YJV-0.6/1KV 4×2.5
3.71 4×16
3.92 4×16
5.49
23
35.9
68
52 YJV-0.6/1KV 4×10
4.39 4×16
4.65 3×25+1×16
4.27
26
42.5
91
69 YJV-0.6/1KV 4×16
3.3 4×16
5.5 3×25+1×16
5.06
26
56.9
116
87 YJV-0.6/1KV 3×25+1×16
穿管管径 (mm)
16
210
DN20
18
290
DN25
18
290
DN25
19
380
DN32
19
380
DN32
22
570
DN32
25
810
DN40
25
810
DN40
28 1210
DN50
28 1210
DN50
30 1530
DN50
33 2010
DN65
33 2010
DN65
电机电缆选配标准表格
穿管管径 (mm)
DN20 DN25 DN25 DN32 DN32 DN32 DN40 DN40 DN50 DN50 DN50 DN65 DN65 DN65 DN80 DN80 DN100 2xDN80 2xDN80 2xDN80 2xDN80 2xDN100 2xDN100 2xDN125 2xDN125
爆炸危险环境,电缆在空气中敷设,周围环境空气温度40℃(二、四、六极电机)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0.55~1.5KW 2.2KW 3KW 4KW 5.5KW 7.5KW 11KW 15KW 18.5KW 22KW 30KW 37KW 45KW 55KW 75KW 90KW 110KW 132KW 160KW 185KW 200KW 220KW 250KW 280KW 315KW 29 29 29 29 38 38 49 68 68 91 116 144 175 224 271 314 360 2*224 2*224 2*314 2*314 2*360 2*410 2*483 2*483 YJV-0.6/1KV 4X2.5 YJV-0.6/1KV 4X2.5 YJV-0.6/1KV 4X2.5 YJV-0.6/1KV 4X2.5 YJV-0.6/1KV 4X4 YJV-0.6/1KV 4X4 YJV-0.6/1KV 4X6 YJV-0.6/1KV 4X10 YJV-0.6/1KV 4X10 YJV-0.6/1KV 4X16 YJV-0.6/1KV 3X25+1X16 YJV-0.6/1KV 3X35+1X16 YJV-0.6/1KV 3X50+1X25 YJV-0.6/1KV 3X70+1X35 YJV-0.6/1KV 3X95+1X50 YJV-0.6/1KV 3X120+1X70 YJV-0.6/1KV 3X150+1X70 YJV-0.6/1KV 2-(3X70+1X35) YJV-0.6/1KV 2-(3X95+1X50) YJV-0.6/1KV 2-(3X120+1X70) YJV-0.6/1KV 2-(3X120+1X70) YJV-0.6/1KV 2-(3X150+1X70) YJV-0.6/1KV 2-(3X185+1X95) 2 2.94 4 3.88 3.43 4.55 4.48 3.71 4.39 3.3 2.9 2.63 2.27 2.07 2.21 2.17 2.25 2.43 2.3 2.21 2.38 2.2 2.21 4X4 4X4 4X6 4X6 4X10 4X16 4X16 4X16 3X25+1X16 3X35+1X16 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X70+1X35) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X240+1X120) 2-(3X240+1X120) 4X2.5 3.5 3.67 3.35 4.34 3.83 5.09 4.6 3.92 4.65 5.5 4.84 4.38 3.79 3.45 3.68 3.61 3.76 4.05 3.83 3.68 3.97 3.67 3.68 3.47 3.86 4X2.5 4X4 4X4 4X6 4X6 4X10 4X16 4X16 3X25+1X16 3X25+1X16 3X35+1X16 3X50+1X25 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X95+1X50) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X240+1X120) 2-(3X240+1X120) 4.67 3.45 4.69 4.07 5.36 4.4 4.08 5.49 4.27 5.06 4.96 4.44 5.3 4.83 5.15 5.05 5.26 4.45 5.37 5.15 5.56 5.14 5.15 4.86 5.41 14 15 15 17 17 19 23 23 26 26 28 30 30 34 38 43.5 47 38 38 43.5 43.5 47 52 58 58 53 59 210 290 290 380 380 570 810 810 1210 1210 1530 2010 2010 2570 3718 4634 5940 7436 7436 9268 9268 11880 14760 18756 18756
电机电缆选配标准表格
电机电缆选配标准表格篇一:电机电缆选型这要看你负载性质P功率(单位W)、I电流(单位A)、U电压(单位V)电阻性负载如电热、白炽灯、卤钨灯I=P÷U功率因数小于1的照明设备:单相220V I=P÷(U×功率因数)三相四线380V I=P÷(1.73×380×功率因数)电动机电流计算方式:单相I=P÷(220×功率因数×效率)三相I=P÷(1.73×380×功率因数×效率)根据电流选择电线有很多种情况要考虑:1 铜线还是铝线。
2 塑料绝缘线、橡皮绝缘线、护套线。
3 绝缘导线安全载流量的温度校正系数。
由于太麻烦,我给你一种常用的塑料绝缘线明线安装,安全载流量数据(铜线)这是最大载流量,其它的都要相应减小。
1.0(平方毫米)---17(A) 1.5---——21 2.5---——28 4-————35 6--————48 10————65 16————91 25——----120 35————147 50————187 70————230篇二:电机动力电缆选型一台22kw电动机用多大铜电缆1、选电缆,要根据你的使用情况,才能选合适的电缆,在潮湿等散热条件好的地方,可以节省一点,在高温和重要地方,则必须选较大截面积的电缆。
一般三相380V22KW 选6-10平方的比较合适。
2、电缆按正常运行配置,和启动方式无关。
22KW负荷选择电缆I=P/1.732UcosΦ=22/1.732/0.38/0.8=20/0.53=42A如果是近距离(几十米以内),铜电缆6平方毫米,铝电缆10平方毫米。
如果是远距离,百米以上,铜电缆16平方毫米,铝电缆25平方毫米如果介于近距离与远距离之间,铜电缆10平方毫米,铝电缆16平方毫米。
今天无意看到这个问题发现很多人在误导大家。
所以把手册中的计算拿出来。
电机配线表
直流电动机配线表
交流电动机配线表
注:三相二百二电机,千瓦三点五安培;常用三百八电机,一个千瓦两安培。
导线安全载流量计算口诀
铝10下五,16、25四,35、50三,70、95两倍半,100上二。
穿管、温度八、九折,裸线加一半。
铜线升级算。
口诀中的阿拉伯数字与倍数的排列关系如下:
对于1.5、2.5、4、6、10mm2的导线可将其截面积数乘以5倍。
对于16、25mm2的导线可将其截面积数乘以4倍。
对于35、50mm2的导线可将其截面积数乘以3倍。
对于70、95mm2的导线可将其截面积数乘以2.5倍。
对于120、150、185mm2的导线可将其截面积数乘以2倍。
补偿导线配热电偶
注:红为正极。
电机电缆选配标准表格
5.05 3X120+1X70
5.05
240 YJV-0.6/1KV 3X120+1X70
2.65 3X120+1X70
4.42 3X150+1X70
5.26 3X150+1X70
5.26
277 YJV-0.6/1KV 3X150+1X70
2.69 3X150+1X70
4.48 3X185+1X95
3.43 4X6
3.83 4X6
5.36 4X6
7.66
7.5KW
15.4
38
29 YJV-0.6/1KV 4X4
4.55 4X6
5.09 4X10
4.4 4X10
6.29
11KW
22.6
49
37 YJV-0.6/1KV 4X6
4.48 4X10
4.6 4X16
4.08 4X16
5.83
15KW
30.3
电缆规格
线路压降 电缆规格
线路压降 电缆规格 线路压降 电缆规格 线路压降
250KW
460
2*360 2*277 YJV-0.6/1KV 2-(3X150+1X70) 2.55 2-(3X150+1X70) 4.26 2-(3X185+1X95) 5.15 2-(3X185+1X95) 5.15
280KW
2*314 2*240 YJV-0.6/1KV 2-(3X120+1X70) 2.21 2-(3X120+1X70) 3.68 2-(3X120+1X70) 5.15 2-(3X120+1X70) 7.36
电机配线表
直流电动机配线表
交流电动机配线表
注:三相二百二电机,千瓦三点五安培;常用三百八电机,一个千瓦两安培。
导线安全载流量计算口诀
铝10下五, 16、25四,35、50三,70、95两倍半, 100上二。
穿管、温度八、九折,裸线加一半。
铜线升级算。
口诀中的阿拉伯数字与倍数的排列关系如下:
对于、、4、6、10mm2的导线可将其截面积数乘以5倍。
对于16、25mm2的导线可将其截面积数乘以4倍。
对于35、50mm2的导线可将其截面积数乘以3倍。
对于70、95mm2?的导线可将其截面积数乘以倍。
对于120、150、185mm2的导线可将其截面积数乘以2倍。
补偿导线配热电偶
注:红为正极。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
穿管管径 (mm)
DN20 DN25 DN25 DN32 DN32 DN32 DN40 DN40 DN50 DN50 DN50 DN65 DN65 DN65 DN80 DN80 DN100 2xDN80 2xDN80 2xDN80 2xDN80 2xDN100 2xDN100 2xDN125 2xDN125
电缆规格
电缆规格
YJV 重量 YJV22 (kg/km)
普通环境,电缆在空气中敷设,周围环境空气温度40℃(二、四、六极电机)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0.55~1.5KW 2.2KW 3KW 4KW 5.5KW 7.5KW 11KW 15KW 18.5KW 22KW 30KW 37KW 45KW 55KW 75KW 90KW 110KW 132KW 160KW 185KW 200KW 220KW 250KW 280KW 315KW 3.4 5 6.8 8.8 11.6 15.4 22.6 30.3 35.9 42.5 56.9 70.4 84.2 103 140 166 203 242 292 338 365 397 460 514 572 29 29 29 29 38 38 49 68 68 91 116 116 144 175 224 271 314 360 2*224 2*271 2*271 2*314 2*360 2*410 2*410 21 21 21 21 29 29 37 52 52 69 87 87 109 133 170 207 240 277 2*170 2*207 2*207 2*240 2*277 2*316 2*316 YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV 4X2.5 4X2.5 4X2.5 4X2.5 4X4 4X4 4X6 4X10 4X10 4X16 3X25+1X16 3X25+1X16 3X35+1X16 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X70+1X35) 2-(3X95+1X50) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X185+1X95) 2 2.94 4 3.88 3.43 4.55 4.48 3.71 4.39 3.3 2.9 3.59 3.14 2.78 2.8 2.61 2.65 2.69 2.72 2.66 2.87 2.59 2.55 2.48 2.75 4X2.5 4X2.5 4X4 4X4 4X6 4X6 4X10 4X16 4X16 4X16 3X25+1X16 3X35+1X16 3X50+1X25 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X70+1X35) 2-(3X95+1X50) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X240+1X120) 2-(3X240+1X120) 3.5 3.67 3.35 4.34 3.83 5.09 4.6 3.92 4.65 5.5 4.84 4.38 3.79 4.6 4.69 4.35 4.42 4.48 4.53 4.44 4.79 4.32 4.26 4.11 4.57 4X2.5 4X4 4X4 4X6 4X6 4X10 4X16 4X16 3X25+1X16 3X25+1X16 3X35+1X16 3X50+1X25 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 3X185+1X95 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X240+1X120) 2-(3X240+1X120) 4.67 3.45 4.69 4.07 5.36 4.4 4.08 5.49 4.27 5.06 4.96 4.44 5.3 4.83 5.15 5.05 5.26 5.42 5.37 5.15 5.56 5.14 5.15 4.86 5.41 14 15 15 17 17 19 23 23 26 26 28 30 30 34 38 43.5 47 38 38 43.5 43.5 47 52 58 58 53 59 16 18 18 19 19 22 25 25 28 28 30 33 33 37 40 44 48 53 210 290 290 380 380 570 810 810 1210 1210 1530 2010 2010 2570 3718 4634 5940 7380 7436 9268 9268 11880 14760 18756 18756
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0.55~1.5KW 2.2KW 3KW 4KW 5.5KW 7.5KW 11KW 15KW 18.5KW 22KW 30KW 37KW 45KW 55KW 75KW 90KW 110KW 132KW 160KW 185KW 200KW 220KW 250KW 280KW 315KW 3.4 5 6.8 8.8 11.6 15.4 22.6 30.3 35.9 42.5 56.9 70.4 84.2 103 140 166 203 242 292 338 365 397 460 514 572 29 29 29 29 38 38 49 68 68 91 116 144 175 224 271 314 360 2*224 2*224 2*314 2*314 2*360 2*410 2*483 2*483 21 21 21 21 29 29 37 52 52 69 87 109 133 170 207 240 277 2*170 2*207 2*240 2*240 2*277 2*316 2*374 2*374 YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV YJV-0.6/1KV 4X2.5 4X2.5 4X2.5 4X2.5 4X4 4X4 4X6 4X10 4X10 4X16 3X25+1X16 3X35+1X16 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X70+1X35) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2 2.94 4 3.88 3.43 4.55 4.48 3.71 4.39 3.3 2.9 2.63 2.27 2.07 2.21 2.17 2.25 2.43 2.3 2.21 2.38 2.2 2.21 4X4 4X4 4X6 4X6 4X10 4X16 4X16 4X16 3X25+1X16 3X35+1X16 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X70+1X35) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X240+1X120) 2-(3X240+1X120) 4X2.5 3.5 3.67 3.35 4.34 3.83 5.09 4.6 3.92 4.65 5.5 4.84 4.38 3.79 3.45 3.68 3.61 3.76 4.05 3.83 3.68 3.97 3.67 3.68 3.47 3.86 4X2.5 4X4 4X4 4X6 4X6 4X10 4X16 4X16 3X25+1X16 3X25+1X16 3X35+1X16 3X50+1X25 3X50+1X25 3X70+1X35 3X95+1X50 3X120+1X70 3X150+1X70 2-(3X95+1X50) 2-(3X95+1X50) 2-(3X120+1X70) 2-(3X120+1X70) 2-(3X150+1X70) 2-(3X185+1X95) 2-(3X240+1X120) 2-(3X240+1X120) 4.67 3.45 4.69 4.07 5.36 4.4 4.08 5.49 4.27 5.06 4.96 4.44 5.3 4.83 5.15 5.05 5.26 4.45 5.37 5.15 5.56 5.14 5.15 4.86 5.41 14 15 15 17 17 19 23 23 26 26 28 30 30 34 38 43.5 47 38 38 43.5 43.5 47 52 58 58 53 59 16 18 18 19 19 22 25 25 28 28 30 33 33 37 40 44 48 210 290 290 380 380 570 810 810 1210 1210 1530 2010 2010 2570 3718 4634 5940 7436 7436 9268 9268 11880 14760 18756 18756