医气紫铜管系统的充氮保护焊接流程
英文回答:
The process of nitrogen protection welding for medical gas copper tube systems involves several steps. Here is a detailed description of the welding process:
1. Preparation: Before starting the welding process, it is important to ensure that the copper tubes are clean and free from any contaminants. Any dirt, grease, or oxide layers should be removed using a suitable cleaning agent.
2. Purging: To create a nitrogen-rich atmosphere inside the copper tube system, purging is necessary. This involves flushing the system with nitrogen gas to displace any air or oxygen present. The purging process should continue
until the oxygen level inside the system is below 0.5%.
3. Welding: Once the purging is complete, the welding process can begin. The welding method used for medical gas
copper tube systems is typically TIG (Tungsten Inert Gas) welding. TIG welding provides precise control over the heat input and minimizes the risk of contamination.
4. Nitrogen flow: During the welding process, a continuous flow of nitrogen gas is maintained to protect the weld area from oxidation. The nitrogen gas creates a shield around the weld, preventing contact with atmospheric oxygen.
5. Post-welding: After completing the weld, it is essential to inspect the joint for any defects. This can be done visually or using non-destructive testing methods such as dye penetrant testing or X-ray inspection.
6. Cleaning: Once the weld has been inspected and approved, any residual flux or contaminants should be removed from the welded area. This can be done using a suitable cleaning agent and a clean cloth.
7. Final inspection: After cleaning, a final inspection should be carried out to ensure the weld meets the required
standards and specifications. This may include checking for proper penetration, smoothness, and absence of any visible defects.
中文回答:
医用气体紫铜管系统充氮保护焊接流程包括以下几个步骤:
1. 准备工作,在开始焊接之前,需要确保紫铜管清洁无污染。

使用适当的清洁剂去除任何污垢、油脂或氧化层。

2. 气体净化,为了在紫铜管系统内创造富氮气氛,需要进行净化。

这涉及使用氮气冲洗系统,以排除任何空气或氧气。

净化过程应持续进行,直到系统内的氧气水平低于0.5%。

3. 焊接,净化完成后,可以开始焊接过程。

医用气体紫铜管系统通常采用TIG(钨极氩弧焊)焊接方法。

TIG焊接提供对热输入的精确控制,并最大程度地减少污染的风险。

4. 氮气流动,在焊接过程中,需要保持连续的氮气流动,以保护焊接区域免受氧化。

氮气在焊缝周围形成保护层,防止与大气中的氧气接触。

5. 焊后处理,完成焊接后,需要检查接头是否存在任何缺陷。

可以通过目视检查或使用渗透剂检测或X射线检查等无损检测方法进行。

6. 清洁,在检查和批准焊缝后,应从焊接区域清除任何残留的焊剂或污染物。

可以使用适当的清洁剂和干净的布进行清洁。

7. 最终检验,清洁后,应进行最终检验,以确保焊缝符合所需的标准和规范。

这可能包括检查焊缝的渗透性、光滑度和无可见缺陷。