SMC比例阀说明书

合集下载

SMC比例阀中文说明书

SMC比例阀中文说明书

产品名称:SMC比例阀中文说明书
阀对流量的控制可以分为两种:
一种是开关控制:要么全开、要么全关,流量要么最大、要么最小,没有中间状态,如普通的电磁直通阀、电磁换向阀、电液换向阀。

另一种是连续控制:阀口可以根据需要打开任意一个开度,由此控制通过流量的大小,这类阀有手动控制的,如节流阀,也有电控的,如比例阀、伺服阀。

所以使用比例阀或伺服阀的目的就是:以电控方式实现对流量的节流控制(当然经过结构上的改动也可实现压力控制等),既然是节流控制,就必然有能量损失,伺服阀和其它阀不同的是,它的能量损失更大一些,因为它需要一定的流量来维持前置级控制油路的工作。

SMC SZ3000-TF2Z507EN 5口阀门式压力调节器说明书

SMC SZ3000-TF2Z507EN 5口阀门式压力调节器说明书

Instruction Manual5 Port Solenoid Valve/Cassette Type ManifoldSeries SZ3000The intended use of this valve is to control the movement of an actuator.1 Safety InstructionsThese safety instructions are intended to prevent hazardous situationsand/or equipment damage. These instructions indicate the level ofpotential hazard with the labels of “Caution,” “Warning” or “Danger.”They are all important notes for safety and must be followed in additionto International Standards (ISO/IEC) *1), and other safety regulations.*1) ISO 4414: Pneumatic fluid power - General rules relating to systems.ISO 4413: Hydraulic fluid power - General rules relating to systems.IEC 60204-1: Safety of machinery - Electrical equipment of machines.(Part 1: General requirements)ISO 10218-1: Robots and robotic devices - Safety requirements forindustrial robots - Part 1: Robots.•Refer to product catalogue, Operation Manual and HandlingPrecautions for SMC Products for additional information.• Keep this manual in a safe place for future reference.Caution Caution indicates a hazard with a low level of risk which, ifnot avoided, could result in minor or moderate injury.Warning Warning indicates a hazard with a medium level of riskwhich, if not avoided, could result in death or serious injury.Danger Danger indicates a hazard with a high level of risk which, ifnot avoided, will result in death or serious injury.Warning•Always ensure compliance with relevant safety laws andstandards.•All work must be carried out in a safe manner by a qualified person incompliance with applicable national regulations.Caution•The product is provided for use in manufacturing industries only. Donot use in residential premises.2 Specifications2.1 Valve specificationsFluid AirInternal pilotoperatingpressurerange [MPa]2 position single 0.15 to 0.72 position double 0.1 to 0.73 position 0.2 to 0.74 position dual 3 port 0.15 to 0.7External pilotpressurerange [MPa]Operating pressure range -100 kPa to 0.7Pilotpressurerange2 position single0.25 to 0.72 position double3 positionAmbien and fluid temperature [˚C]-10 to 50 (No freezing)Flow rate characteristicsRefer to catalogueResponse timeDuty cycle Contact SMCMinimum operating frequency 1 cycle / 30 daysMaximumoperatingfrequency [Hz]2 position single, double,4 position dual 3 port valve103 position 32 Specifications - continuedManual override (manual operation)Non-locking push typePush-turn locking slotted typeLubrication Not requiredImpact/Vibration resistance [m/s2] Note 150 / 30Enclosure (based on IEC60529) IP40Mounting orientation UnrestrictedWeight Refer to cataloguePilot type Common exhaustTable 1.Note 1) Impact resistance: No malfunction occurred when it was tested in the axialdirection and at right angles to the main valve and armature in bothenergized and de-energized states. Each condition was tested once.(Values quoted are for a new valve).Vibration resistance: No malfunction occurred in a one-sweep test between45 and 2000 Hz. Test was performed in both energized and de-energizedstates in the axial direction and at right angles to the main valve andarmature. (Values quoted are for a new valve).2.2 Solenoid specificationsElectricalentryPlug-in, EX140, EX510 L type plug connector (L)Non plug-in M type plug connector (M)Coil rated voltage [VDC] 24, 12Allowable voltage fluctuation ±10% of rated voltageCoil insulation class Contact SMCPower consumption [W] 0.6 (With light: 0.65)Surge voltage suppressor DiodeIndicator light LEDTable 2.Note 1) Only 24 VDC and 12 VDC are available for plug-in use.2.3 Manifold specificationsModelD-subType 60FFlat ribbon cable type 60P#SS5Z3-60Type 60P Type 60PG Type 60PHManifold type Plug-in (L)Non plug-in(M)1(P:SUP)/3/5(R: EXH) systemCommon SUP, EXHValve stations 2 to 20 2 to 16 2 to 8 2 to 204(A)/2(B)portLocation ValveDirection Lateral, upward, downwardPortsize1(P), 3/5(R) C84(A), 2(B) C4, C6, M5Table 3.2.4 Pneumatic symbolsRefer to catalogue Pneumatic symbols.2.5 Indicator lightM type plug connector L type plug connectorFigure 1.2.6 Special productsWarningSpecial products (-X) might have specifications different from thoseshown in this section. Contact SMC for specific drawings.3 Installation3.1 InstallationWarning•Do not install the product unless the safety instructions have been readand understood.3.2 EnvironmentWarning•Do not use in an environment where corrosive gases, chemicals, saltwater or steam are present.3 Installation - continued•Do not use in an explosive atmosphere.•Do not expose to direct sunlight. Use a suitable protective cover.•Do not install in a location subject to vibration or impact in excess ofthe product’s specifications.•Do not mount in a location exposed to radiant heat that would result intemperatures in excess of the product’s specifications.3.3 PipingCaution•Before connecting piping make sure to clean up chips, cutting oil, dustetc.•When installing piping or fittings, ensure sealant material does notenter inside the port. When using seal tape, leave 1 thread exposedon the end of the pipe/fitting.•Tighten fittings to the specified tightening torque.3.4 LubricationCaution•SMC products have been lubricated for life at manufacture, and do notrequire lubrication in service.•If a lubricant is used in the system, refer to catalogue for details.3.5 Air supplyWarning•Use clean air. If the compressed air supply includes chemicals,synthetic materials (including organic solvents), salinity, corrosive gasetc., it can lead to damage or malfunction.Caution•Install an air filter upstream of the valve. Select an air filter with afiltration size of 5 μm or smaller.3.6 Manual overrideWarning•Regardless of an electric signal for the valve, the manual override isused for switching the main valve. Since connected equipment willoperate when the manual override is activated, confirm that conditionsare safe prior to activation.•Locked manual overrides might prevent the valve responding to beingelectrically de-energised or cause unexpected movement in theequipment.•Refer to the catalogue for details of manual override operation.Non-locking push type Push-turn locking slotted typeFigure 2. – Position is the same on L and M types3.7 Valves with switches (L type plug-in only)WarningWhen turning OFF with the switch, be sure to move the switch to thelocked position. Connected equipment may be actuated if current flowoccurs with the switch at an improper position.ON position OFF positionNormal operating condition.Switching off valve is based onan electric signal from theconnector.The valve coil is kept in adeenergized state even when thereis an electric signal from theconnector.Figure 3.3 Installation - continued3.8 Electrical circuitsCautionIf a valve type without suppression is used, suppression should beprovided as close as possible to the valve by the host controller.Pos. common specifications Neg. common specificationsSingle solenoid type Single solenoid typeLight/surge voltage suppressorSurge voltage suppressorDouble solenoid, 3 position,4 positionDouble solenoid, 3 position,4 positionLight/surge voltage suppressorSurge voltage suppressorValves with switches (with light/surge voltage suppressor)-Figure 4.Note) Make sure that the polarity is matched on the connector’s (+), (-) and A, Band COM indicators. In case of voltage specifications other than 12 or 24VDC, take care to avoid mistaking polarity, as there is no diode to preventreverse current. In the event that lead wires are connected in advance, theywill be as shown below.Pos. common specifications Neg. common specificationsA (-): BlackCOM (+): RedB (-): White (no lead wire forsingle solenoid)A (+): BlackCOM (-): RedB (+): White (no lead wire for singlesolenoid)3.9 Residual voltageCaution•The suppressor arrests the back EMF voltage from the coil to a levelin proportion to the rated voltage.ORIGINAL INSTRUCTIONSSol.AManual overridefor Sol.B (Green)Manual overridefor Sol.A (Orange)Sol.BSol.AManual overridefor Sol.B (Green)Manual overridefor Sol.A (Orange)Sol.BSolenoid ASolenoid BLightA: RedB: GreenDiode to preventreverse currentCoilCOMRed (+)[SOL.a]Black (-)LED(Red)Diode to preventreverse currentCoilCOMYellow (-)[SOL.a]Black (+)LED(Red)Diode to preventreverse currentCoilCOMRed (+)[SOL.a]Black (-)Diode to preventreverse currentCoilCOMYellow (-)[SOL.a]Black (+)Diode to preventreverse currentCoil[Sol.b]White (-)[SOL.a]Black (-)LED(Red)COMRed (+)CoilLED(Green)Diode to preventreverse currentCoil[Sol.b]White (-)[SOL.a]Black (-)COMRed (+)CoilDiode to preventreverse currentCoil[Sol.b]White (+)[SOL.a]Black (+)LED(Red)COMYellow (-)CoilLED(Green)Diode to preventreverse currentCoil[Sol.b]White (+)[SOL.a]Black (+)COMYellow (-)CoilSwitchCoil[Sol.b](-)[SOL.a](-)SwitchCoilCOM(+)LED(Green)LED(Red)3 Installation - continued•Ensure the transient voltage is within the specification of the hostcontroller.•In the case of a diode, the residual voltage is approximately 1 V.•Valve response time is dependent on surge suppression methodselected.3.10 Countermeasure for surge voltageCaution•At times of sudden interruption of the power supply, the energy storedin a large inductive device may cause non-polar type valves in a de-energised state to switch.•When installing a breaker circuit to isolate the power, consider a valvewith polarity (with polarity protection diode), or install a surgeabsorption diode across the output of the breaker.3.11 Extended period of continuous energizationWarningIf a valve will be continuously energized for an extended period of time,the temperature of the valve will increase due to the heat generated bythe coil assembly. This will likely adversely affect the performance of thevalve and any nearby peripheral equipment. Therefore, if the valve is tobe energized for periods of longer than 30 minutes at a time or if duringthe hours of operation the energized period per day is longer than the de-energized period, we advise using a 0.4 W or lower valves, such as theSY series, or a valve with power-saving circuit.3.12 Effect of back pressure when using a manifoldWarning•Use caution when valves are used on a manifold because an actuatormay malfunction due to back-pressure.•Special caution must be taken when using 3 position exhaust centrevalve or when driving a single acting cylinder. To prevent amalfunction, implement counter measures such as using a single EXHspacer assembly or an individual exhaust manifold.3.13 Manifold electrical wiring specificationsRefer to catalogue for manifold electrical wiring specifications.3.14 How to use plug connectorRefer to catalogue for additional information.3.14.1 Attaching and detaching connectorsFigure 5.3.14.2 Crimping of lead wires and socketsFigure 6.3.14.3 Attaching and detaching lead wires with socketsFigure 7.3 Installation - continued3.15 Common connector assembly wiringRefer to catalogue for additional information.Figure 8. Common connector assembly wiring3.16 Exhaust restrictionCautionSince the SZ series is a type in which the pilot valve exhaust joins themain valve exhaust inside the valve, care must be taken that the pipingfrom the exhaust port is not restricted.3.17 Use as a 3-port valveCautionThe SZ3000 series valves can be used as normally closed (N.C.) ornormally open (N.O.) 3 port valves by closing one of the cylinder ports (Aor B) with a plug. However, they should be used with the exhaust portskept open. They are convenient at times when a double solenoid type 3port valve is required.Plug position B port A portType of actuation N.C. N.O.NumberofsolenoidsSingleDoubleTable 4.3.18 One-touch fittings3.18.1 Tube attachment and detachmentCautionRefer to the Specific Precautions in the catalogue.3.18.2 Precautions on other tube brandsCautionWhen using non-SMC brand tubes, refer to the Specific Precautions inthe catalogue.3.19 Built-in back pressure check valveCaution•Valves with built-in back pressure check valve is to protect the backpressure inside a valve. For this reason, use caution that the valveswith external pilot specification cannot be pressurized from exhaustport [3(R)]. As compared with the types which do not integrate the backpressure check valve, C value of the flow rate characteristics goesdown. For details, please contact SMC.•Do not switch valves when A or B port is open to the atmosphere, orwhile the actuators and air operated equipment are in operation. Theback pressure prevention seal may be peeled off, which may cause airleakage or malfunctions. Use caution especially when performing atrial operation or maintenance work.4 Settings4.1 Changing the connector entry directionCaution•Since lead wires are attached to the connector, excessive pulling ortwisting can cause broken wires or other issues. Also, take care thatlead wires are not pinched when installing the connector.•If an excessive force is applied on the connector in the ‘LOCK’ position,the connector block may be damaged. Connector lead wires maybreak If the switch is in the ‘FREE’ position during operation. Ensurethe switch is moved back in ‘LOCK’ position.•Refer to catalogue for additional information.Figure 9.5 How to OrderRefer to catalogue for ‘How to Order’ or to product drawing for specialproducts.6 Outline DimensionsRefer to catalogue for outline dimensions.7 Maintenance7.1 General maintenanceCaution•Not following proper maintenance procedures could cause the productto malfunction and lead to equipment damage.•If handled improperly, compressed air can be dangerous.•Maintenance of pneumatic systems should be performed only byqualified personnel.•Before performing maintenance, turn off the power supply and be sureto cut off the supply pressure. Confirm that the air is released toatmosphere.•After installation and maintenance, apply operating pressure andpower to the equipment and perform appropriate functional andleakage tests to make sure the equipment is installed correctly.•If any electrical connections are disturbed during maintenance, ensurethey are reconnected correctly and safety checks are carried out asrequired to ensure continued compliance with applicable nationalregulations.•Do not make any modification to the product.•Do not disassemble the product, unless required by installation ormaintenance instructions.7.2 Fitting assembly replacementRefer to catalogue for additional information.Figure 10.7.3 Manifold expansion and replacement parts•When disassembly and assembly are performed, air leakage mayresult if connections between blocks and tightening of the end block’sholding screw, is inadequate. Before supplying air, confirm that thereare no gaps, etc. between blocks, and that manifold blocks aresecurely fastened to the DIN rail. Then supply air and confirm that thereis no air leakage before operating.•Tighten the DIN rail holding screw to the recommended torque of 1.4N∙m.•Refer to catalogue for additional information and replacement parts.8 Limitations of Use8.1 Limited warranty and disclaimer/compliance requirementsRefer to Handling Precautions for SMC Products.Warning8.2 Cannot be used as an emergency shut-off valveThis product is not designed for safety applications such as anemergency shut-off valve. If the valves are used in this type of system,other reliable safety assurance measures should be adopted.8.3 Holding of pressure (including vacuum)Since valves are subject to air leakage, they cannot be used forapplications such as holding pressure (including vacuum) in a system.8.4 Intermediate stoppingRefer to Handling Precautions for 3/4/5 port Solenoid Valves.8.5 Air returned or air/spring returned spool valves•The use of 2-position single valves with air returned or air/springreturned spools has to be carefully considered.•The return of the valve spool into the de-energized position dependson the pilot pressure. If the pilot pressure drops below the specifiedoperating pressure the position of the spool cannot be defined.•The design of the system must take into account such behaviour.•Additional measures might be necessary. For example, the installationof an additional air tank to maintain the pilot pressure. Such measuresmust be evaluated by risk assessment within the validation process.EnergysourcestatusSingle Double 3 position 4 positionAir supplypresent,electricitycutSpool returns tothe off positionby air forceSpool stopsmoving afterelectricity cut(Position cannotbe defined)Spool returnsto off positionby spring forceSpools return tooff position by airforceAir supplycut beforeelectricitycutSpool stopsmoving after airpressure cut(Position cannotbe defined)Spool stopsmoving after airpressure cut(Position cannotbe defined)Spool returnsto off positionby spring forceSpool stopsmoving after airpressure cut(Position cannotbe defined)Table 5.Caution8.6 Leakage voltageEnsure that any leakage voltage caused by the leakage current when theswitching element is OFF is ≤ 3% of the rated voltage across the valve.8.7 Low temperature operationUnless otherwise indicated in the specifications for each valve, operationis possible to -10˚C, but appropriate measures should be taken to avoidsolidification or freezing of drainage and moisture, etc.8.8 Momentary energizationIf a double solenoid valve is operated with momentary energization, itshould be energized for at least 0.1 second. However, depending on thesecondary load conditions, it should be energized until the cylinderreaches the stroke end position, as there is a possibility of malfunctionotherwise.9 Product DisposalThis product shall not be disposed of as municipal waste. Check yourlocal regulations and guidelines to dispose this product correctly, in orderto reduce the impact on human health and the environment.10 ContactsRefer to or www.smc.eu for your localdistributor/importer.URL : https:// (Global) https:// www.smc.eu (Europe)SMC Corporation, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JapanSpecifications are subject to change without prior notice from the manufacturer.© 2022SMC Corporation All Rights Reserved.Template DKP50047-F-085M CoverConcavePinLeverPolarity indicatorSocketPart no. DXT170-71-1Lead wireConnectorHookCore wirecrimping areaCrimping areaCore wireLead wireSocketHookInsulation0.2 mm2 to 0.33 mm2Max. cover diameter: ∅1.7 mmSocketHookConnectorLead wireInsert into these square holesSwitch for locking a connectorM5 port block assemblyClipO-ringC4 / C6 one-touch fittingO-ringOne-touch fitting(Elbow type)One-touch fitting(Long elbow type)Common wireSocketInsert socket into connector (below COM indicator)of adjacent solenoid valve。

SMC比例阀中文说明书

SMC比例阀中文说明书

ITV1000-※1 ITV2000-※1 ITV3000-※1(模拟输出/电压型)使用说明书值此,谨对您选购SMC 公司的产品表示诚挚的谢意。

请仔细阅读本使用说明书,相信必将有助于您正确使用本产品。

为以防万一,请您一定好好保管此说明书。

安全注意事项这里所描述到的,是提请您正确安全的使用本产品,以防止对您自身和他人造成危害和损害的各种注意事项。

请结合ISO 4414, JIS B 8370以及其他的相关安全规则,务必遵守。

注意关于配管1.请将配管用空气吹净或清洗干净,以除去配管内的切屑,切削油及杂质等。

2.将配管和管接头拧紧时,请注意勿将配管的螺纹切屑及密封材混入配管中。

另需强调,使用密封胶带包卷管接头螺纹时,请在螺纹先端留出1.5~2个螺距的空间。

注意关于压缩气源1. 在靠近本产品的供气侧,请选择安装过滤精度在5μm 以下的空气过滤器。

2. 压缩空气若含有大量的水分,将导致本产品及其他的气动元件作动不良。

请实施相应对策,诸如设置后冷却器,空气干燥器,水分分离器等。

3. 在本产品内部大量附着由空气压缩机所产生的碳粉时,将导致其作动不良。

! !各部分名称外形尺寸配线电缆接线端子安装托架外形尺寸安装孔安装孔UP 键(△键) 设定键(SET 键) DOWN 键(▽键)显示用LEDSUP 接口OUT 接口压力表用接口安装托架(选配)右弯出线型电缆接线端子 (4芯)(选配)安装托架(选配)右弯出线型电缆接线端子直线出线型电缆接线端子 (4芯)(4芯)安装孔安装孔注1) 输出压力0.1MPa规格最大供给压力为0.2MPa。

注2) 超出规格范围时,会发生破损,请注意。

■ 配线方法电缆与本体的端子连接时,请以下记的形式进行配线。

注意因可能发生由于误配线而导致破损的情况,请使用时注意。

请使用容量足够大,脉动小的直流电源。

1 茶 供给电源2 白 输入信号3 青 GND (COMMON)4 黑显示输出注)电缆也有右弯出线型的。

SMC ITV1000,2000,3000电气比例阀设定手册

SMC ITV1000,2000,3000电气比例阀设定手册

ITV1000-※1 ITV2000-※1 ITV3000-※1(模拟输出/电压型)使用说明书值此,谨对您选购SMC 公司的产品表示诚挚的谢意。

请仔细阅读本使用说明书之后正确使用本产品。

为了今后使用方便,请您妥善保管此使用说明书。

安全注意事项这里所指的注意事项,是为了让您正确安全的使用本产品,防止对您自身和他人造成危害和损害的各种事项。

请在遵守以下安全注意事项的同时,也请务必遵守ISO 4414, JIS B 8370以及其他的相关安全规则。

注意关于配管1.请将配管用空气吹净或清洗干净,以除去配管内的切屑,切削油及杂质等。

2.连接配管和接头时,请注意勿将配管的屑末及密封材混入配管中。

使用密封胶带时,务必在螺纹先端留出1.5~2个螺距的空间。

注意关于压缩气源1. 在靠近本产品的供气侧,请选择安装过滤精度在5μm 以下的空气过滤器。

2. 压缩空气若含有大量的水分,将导致本产品及其他的气动元件作动不良。

请实施相应对策,诸如设置后冷却器,空气干燥器,水分分离器等。

3. 在本产品内部大量附着由空气压缩机所产生的碳粉时,将导致其作动不良。

! !各部分名称外形尺寸配线电缆接线端子设定键(SET 键) DOWN 键(▽键)显示用LEDSUP 接口OUT 接口压力表用接口UP 键(△键) 安装托架(选配)右弯出线型电缆接线端子(4芯)安装孔外形尺寸安装托架安装孔安装孔(选配)安装托架(选配)右弯出线型电缆接线端子直线出线型电缆接线端子安装孔■ 规格供给压力 注1) 设定压力+ 0.1MPa,但最大为1MPa0.005~0.1MPa (ITV101※-※1,ITV201※-※1,ITV301※-※1)0.005~0.5MPa (ITV103※-※1,ITV203※-※1,ITV303※-※1)设定压力0.005~0.9MPa (ITV105※-※1,ITV205※-※1,ITV305※-※1)约200L/min (ANR) {ITV1000}(供给压力:0.7MPa)约1500L/min (ANR) {ITV2000}(供给压力:0.7MPa)最大流量约5000L/min (ANR) {ITV3000}(供给压力:0.7MPa)24VDC±10% (ITV10※0-※1,ITV20※0-※1,ITV30※0-※1)电源电压 注2)12~15VDC (ITV10※1-※1,ITV20※1-※1,ITV30※1-※1)电源电压 DC24V型:0.12A以下消费电流电源电压 DC12~15V型:0.18A以下4~20mADC (ITV10※※-01,ITV20※※-01,ITV30※※-01)电流型0~20mADC (ITV10※※-11,ITV20※※-11,ITV30※※-11)0~5VDC (ITV10※※-21,ITV20※※-21,ITV30※※-21)输入信号 注2)电压型0~10VDC (ITV10※※-31,ITV20※※-31,ITV30※※-31)电流型 250Ω以下输入阻抗电压型 约6.5KΩ直线性 ±1.0% F.S.以下延滞性 0.5% F.S.以下重复精度 ±0.5% F.S.以下最小压力调整 :调整范围 额定值的0~50%最大压力调整 :调整范围 额定值的10~100%附加机能键锁定机能 :持续摁住UP键2秒以上,再摁住SET键,可实现对操作键的锁定。

SMC说明书

SMC说明书

SM-14S M C系列阀门电动装置使 用 说 明 书天津百利二通机械有限公司TIANJIN BAILI ERTONG MACHINERY CO.,LTD.目 录第一部分 SMC系列普通型产品使用说明第二部分 SMC系列整体型产品使用说明第三部分 SMC系列隔爆型产品使用说明第四部分 SMC-04~SMC-2低温型产品使用说明第一部分 SMC系列普通型产品使用说明1.概述SMC系列多回转型阀门电动装置(以下称电动装置)用于驱动控制阀瓣作直线运动的闸阀、截止阀、隔膜阀等多回转阀门。

SMC系列中的部分机座产品也可以同BA伞齿轮减速器或直齿轮减速器组合,形成SMC/BA等组合式多回转电动装置。

当SMC系列产品与HBC蜗轮减速器或JA行星减速器组合后则成为组合式部分回转电动装置,它用于驱动控制阀瓣作旋转运动的球阀、蝶阀、旋塞阀等部分回转阀门。

SMC系列电动装置可以远距离电动操作(控制室内操作),可以根据订货要求加装现场按钮灯盒,从而具备现场操作功能。

SMC系列产品的手动机构可完成现场手动操作阀门。

由于SMC/BA、SMC/HBC、SMC/JA等组合型式电动装置的控制、调节部件均在SMC系列产品上,所以本说明书同样适用于上述产品。

(图1)~(图9)所示为SMC、SMC/BA、SMC/HBC、SMC/JA普通型产品的外形主视图。

上述产品的外形和法兰连接尺寸可参见我公司有关产品样本。

所用电动装置的输出转矩、转速、转圈数、电动机功率等详见该电动装置的铭牌。

2.基本技术参数产品符合GB/T24923-2010《普通型阀门电动装置技术条件》2.1动力电源:380V、50Hz(特殊订货可提供220V、415 V、440 V、460 V、480 V、660 V、690 V,50Hz、60Hz)三项正弦交流电(根据用户要求,某些规格可提供单相220V电源的电动机)。

2.2外壳保护等级:IP65~IP67(IP68订货时提出)2.3使用环境温度:-20℃~70℃(根据用户订货要求)2.4环境相对湿度:≤90%(25℃时)2.5海拔高度:≤1000m2.6短时工作:时间定额为10、15、30min(根据电动机负载情况而定)2.7无强烈振动工况。

SMC ITV0000系列说明书

SMC ITV0000系列说明书

单体用、集装式单体用集装式薄型电气比例阀ITV0000系列注)集装式上,附带了根据位数所定长度的DIN导轨。

DIN导轨的尺寸,请参见外形尺寸图。

集装式订购例IITV00-03…………………………1个(集装式型号)※ITV0030-3MS…………………2个(电气比例阀)(1, 2位)3ML…………………1个(电气比例阀)(3位)※符号请附在装载电气比例阀型号的最前面。

注意)由于采用共通给排气,所以不能订购不同的压力范围。

请在集装式型号的下面,一并记入装载的电气比例阀及可选项型号。

从D侧起数为第1表示例)由于采用共通给排气,所以不能进行不同压力范围的组合,请注意。

DIN2位)-05-07(型号表示方法RoH S[可选项]规格附件(可选项)托架电缆插头平托架组件(带2个安装螺钉)P3*******L 形托架组件(带2个安装螺钉)安装时的紧固力矩为0.3N ·mP3*******直通型直角型M8-4DSX3MG4ELWIKA-KV4408 PVC025 2M注1)表示单体的质量。

IITV00-n 的场合、总质量(g)≤位数(n)×100+130(端块A, B 组件的质量)+DIN 导轨的质量(g)。

注2)2次侧有消耗流量的场合,根据配管条件,压力有可能不稳定。

注3)通电时,电磁阀会产生动作音,此非异常。

※在相当于IP65的条件下使用的场合,请在呼吸孔上配置接头,管子基础上使用。

(详见后附3的产品单独注意事项q 。

)薄型电气比例阀ITV0000 系列输入信号一增大,q 给气用电磁阀就变为ON 。

由此,一部分供给压力通过q 给气用电磁阀成为输出压力。

此输出压力通过e 压力传感器,反馈至r 控制回路。

在这里,由于会进行修正动作,直到输出压力与输入信号成比例,因此,通常会得到与输入信号成比例的输出压力。

动作原理压力传感器SUPEXH ITV0000 系列ITV001□系列ITV003□系列薄型电气比例阀ITV0000 系列ITV0000 系列ITV005□系列薄型电气比例阀ITV0000 系列外形尺寸图集装式用单体注)电缆插头的尺寸,请参见P.6单体用。

SMC 电子控制气体阀门用户手册说明书

SMC 电子控制气体阀门用户手册说明书
ISO 4413: Hydraulic fluid power - General rules relating to systems. IEC 60204-1: Safety of machinery - Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Robots and robotic devices - Safety requirements for industrial robots - Part 1: Robots. • Refer to product catalogue, Operation Manual and Handling Precautions for SMC Products for additional information. • Keep this manual in a safe place for future reference.
Minimum operating pressure
Single Double (double solenoid) 3 position 4 position
Ambient and fluid temperature
0.1 MPa
0.15 MPa
0.1 MPa
0.1 MPa
0.1 MPa
0.2 MPa
Danger
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Warning
• Always ensure compliance with relevant safety laws and standards.

SMC电-气比例阀E P REGULATOR ITV 0 0-DE说明书

SMC电-气比例阀E P REGULATOR ITV 0 0-DE说明书

电-气比例阀 E/P REGULATOR机种名称/ MODEL NAMEITV*0*0-DE**** series型 式 / Series《DeviceNet TM对应品》目录P1 为了能够安全使用 P2 使用注意事项P3-4 配线方法及LED 显示 P5-6 安装・设置 P6 开关设定P7 压力设定方法及输出的监控、通信数据 P8 系统构成及用途・目的、产品的主要规格 P9 通信规格、维修・保养P10URL http ://・东京营业所TEL.03-5207-8260 ・名古屋营业所TEL.052-461-3400 ・大阪营业所TEL.06-6459-5160 ・客户技术咨询窗口免费电话 TEL.0120-837-838/MANUAL目 录这里所示的注意事项是为了确保您能安全正确的使用本产品,预先防止对您及他人造成危害或损失而制定的。

为了表示这些事项的危险程度,将注意事项按照伤害和损失的大小及紧急程度分为“注意”“警告”“危险”三个等级。

不论哪种都是与安全相关的重要内容,所以请您在遵守ISO 4414、JIS B 8370以及其他安全规则的同时,也请务必遵守下述内容。

■显示说明显示显示的含义△!警告误操作时,可能使人受到重大伤害甚至死亡的事项。

△!注意误操作时,可能会导致人员受伤,或使物品破损的事项。

△!警告①请由系统设计者或规格制定者来判断本产品的适合性。

本产品系统的适合性,请由系统的设计者或规格的制定者来判断。

必要时请通过分析和试验进行判断。

对于本系统预期的性能、安全性的保证由判断系统适合性的人员负责。

请在参考最新的产品资料,确认规格的全部内容,考虑可能发生的故障的基础上构建系统。

②请具有充分知识和经验的人员使用本产品。

压缩气体若被错误使用会很危险。使用了空压元件的机械・设备的组装、操作、维修保养等作业请由具有充分知识和经验的人进行。

③请务必在确认机械・设备的安全后,再进行产品的使用和拆卸。

SMC系列产品使用说明书

SMC系列产品使用说明书
电气接线程序及注意事项:
7.1确认电源电压与电动机使用电压相同。
7.2对于无现场按钮灯盒的SMC-04、03、00、0、1、2产品,接线前应取下G·L·SW箱罩,(有开度窗的箱罩)这时可见到G·L·SW上部和其前部端子板。进线孔位于主箱体下部、上部或侧面。
对于装有现场按钮灯盒或整体型SMC-04、03、00、0、1、2产品,接线前不仅应取下G·L·SW箱罩,还应取下T·SW箱盖(在主箱体另一测)。因为这时接线端子板多设在T·SW箱体内,T·SW箱体上亦有进线孔。
拆卸时应先将电动装置吊装可靠再松开紧固螺栓,而后将其自阀门上取下。
5.4 SMC/HBC、SMC/JA部分回转产品的安装与拆卸方法是:
先将花键接头装到阀杆上,使电动装置二级减速机构的驱动轴位置与阀门所处位置相同。
(此时阀门在某一终端位置最理想)起吊电动装置,使其驱动轴与阀杆上的花键接头对准,同时应对准阀门与电动装置的连接螺孔。使驱动轴与花键接头配合装入,而后用螺栓将阀门与电动装置紧固可靠。
拆卸时应先将电动装置吊装可靠,松开紧固螺栓将其自阀门上取下。
(注意:无论是多回转或部分回转电动装置,其吊环只允许用于起吊电动装置自身,不得连同阀门一起进行吊装)。
5.5安装前应清洗阀杆并涂润滑脂。明杆多回转阀门应确认其阀杆伸出量要小于阀杆罩高度。
5.6安装时应注意电动阀门在管道上的位置,以保证电动装置有合理的调试、维修空间。
a、型号:该产品型号。
b、最大控制转矩:该产品出厂前调定的最大转矩值(N.m)。
c、输出转速:该产品在单位时间内输出轴的转圈数(r/min)。
d、最大转圈数:该产品位置指示机构指针从0~100%走满刻度情况下输出轴总的转圈数。
e、编号:该产品总序号或本年度产品的序号。

比例阀说明书范文

比例阀说明书范文

比例阀说明书范文比例阀是一种可以根据输入和输出的信号,来调节流体介质流量的装置。

它可以根据需要自动调节流量,使系统能够按照设定值工作。

下面是一份比例阀的说明书。

一、产品概述比例阀是一种用于控制流体介质流量的装置,它通过调节阀芯的开启度来控制流量大小。

比例阀通常由电磁铁、阀芯、弹簧、流量控制电路等部件组成。

电磁铁通过接收输入的电信号,控制阀芯的开启度,进而调节流量大小。

二、产品特点1.控制精确:比例阀采用开环控制,可根据输入信号调节阀芯开启度,使流量精确控制在设定值范围内。

2.反应迅速:比例阀采用电磁铁控制阀芯,电磁铁响应速度快,能够迅速调节阀芯开启度,实现流量的快速调节。

3.耐高压:比例阀采用优质材料制成,能够承受较高的压力,保证工作的稳定性和安全性。

4.耐腐蚀:比例阀采用耐腐蚀材料制成,可以适应各种腐蚀介质的控制,延长使用寿命。

5.体积小巧:比例阀体积小巧,安装方便,可以根据需要进行空间布局。

三、产品应用领域比例阀可广泛应用于以下领域:1.工业自动化控制系统:比例阀可用于控制各种工业流体介质,如液体、气体等,实现流体流量的准确控制。

2.压力控制系统:比例阀可根据输入的压力信号,控制流体介质的流量,保持系统内的压力稳定。

3.温度控制系统:比例阀可根据输入的温度信号,控制流体介质的流量,实现温度的精确控制。

4.液位控制系统:比例阀可根据输入的液位信号,控制液体介质的流量,实现液位的稳定控制。

四、产品使用方法1.安装:将比例阀安装在需要控制流量的管道上,注意连接的密封性和稳定性。

2.输入信号设置:根据实际需要,将输入信号连接到比例阀的控制电路上。

输入信号可以是电压、电流或者其他类型的信号。

3.设定流量范围:根据实际需要,调节比例阀的开启度,设定所需的流量范围。

4.系统调试:将比例阀接通电源,观察输出流量是否符合设定值,如有偏差可以进一步调节阀芯开启度。

五、产品维护与保养1.定期检查:定期检查比例阀的连接是否松动,电磁铁是否正常工作,阀芯是否磨损,如有异常情况及时进行维修或更换。

SMC比例阀使用

SMC比例阀使用

SMC比例阀使用首先,SMC比例阀具有良好的流量控制特性。

通过调节阀门开度,可以精确地控制流体的流量。

由于SMC比例阀采用了先进的比例控制技术,可以实现非常精准的流量控制,满足不同工况下的流量要求。

此外,SMC比例阀具有稳定的性能,可以长时间稳定地工作。

其次,SMC比例阀具有灵活的应用性能。

它可以与不同的控制系统进行配合使用,实现多样化的控制要求。

SMC比例阀可以根据系统需求进行宽范围的调整,适应不同的工况。

同时,SMC比例阀还可以与传感器、执行器等设备进行联动控制,实现更加复杂的自动化控制功能。

另外,SMC比例阀还具有快速的响应速度。

它采用了先进的比例控制技术,能够迅速响应控制信号,实现快速的流量调节。

这种快速响应速度可以提高系统的控制精度和灵敏度,保证系统的稳定性和可靠性。

同时,SMC比例阀还具有一定的节能效果。

由于其精确的流量控制特性,可以减少不必要的能量浪费。

此外,SMC比例阀还可以根据实际需求进行精确的流量调节,避免流量过大或过小导致的能量损失,提高了系统的能源利用效率。

最后,SMC比例阀具有简单的安装和维护。

它的结构简单、尺寸小巧,便于安装在各种设备上。

同时,SMC比例阀采用优质的材料制造,具有良好的耐腐蚀和耐磨损性能,同时也方便清洁和维护。

总之,SMC比例阀是一种广泛应用于工业自动化控制系统中的流量控制设备。

它具有良好的流量控制特性、灵活的应用性能、快速的响应速度、一定的节能效果以及简单的安装和维护。

通过合理应用SMC比例阀,可以实现系统的精确控制和高效运行,提高了工业生产的效率和品质。

SMC 4口阀门簇类型产品说明书

SMC 4口阀门簇类型产品说明书

SJ2000 / 3000
Pilot exhaust method
Internal pilot External pilot
Air
0.15 to 0.7
0.1 to 0.7 0.2 to 0.7 -100 kPa to 0.7
0.25 to 0.7
-10 to 50 (no freezing)
Refer to catalogue
SJ-SMX191E
ORIGINAL INSTRUCTIONS
Instruction Manual 4 Port Solenoid Valve Cassette Type Manifold Series SJ1000/2000/3000
The intended use of this valve is to control the movement of an actuator.
Common SUP, EXH
Connector
Valve stations (maximum)
type: 1 to 24 Cable type:
1 to 18
1 to 8 1 to 32
1 to 16
1 to 20
2 to 20
Max. number of pins (points)
25
26
20
10
Table 3.
2.4 Pneumatic symbols Refer to catalogue for pneumatic symbols.
2.5 Light indicator
60
Manifold type
SJ1000 SJ2000 SJ3000
Plug-in, connector type

SMC IC系列 电气比例阀用控制器 说明书

SMC IC系列 电气比例阀用控制器 说明书

输出形式:NPN/PNP开路集电极输出 N.O., N.C.模式可切换 5~640ms 压力显示:3 1/2位数LED显示(红色) 输出电源电压、 电流信号显示:1位数LED显示 (红色) RUN.CH,SW用LED灯(红色、 绿色)
0 NPN开路集电极输出 1 PNP开路集电极输出
安装规格 无记号 无 A 面板安装
RUN
CH SW
1 2 3 4 1 2 3 4
kPa
SET
D-IN P-ON
READ STOP DOWN
UP RUN
105.5
45
123 100.5 70 6 M5 x 0.8 x 5 传感器压力导入通口
M3 x 0.5 x 9.5 传感器呼吸通口
kPa
附传感器型
48
CONTOROLLER
OUT PRESSURE
!"#$%&'
IC
电源 控制器 电气比例阀
规格
压力范围 适合流体 供给电源 0.1MPa 0.5MPa 0.9MPa -100kPa 空气 · 非腐蚀性气体 DC12~24V(15W以上), 波动1%以下 ①输入点数 : 从程序控制器最大10bit输入(并联) 输入方法 : 无电压触点或NPN开路集电极输入 输入
外形尺寸图 (毫米)
内置传感器型
48
CONTOROLLER
OUT PRESSURE
123 100.5 70 6
M3 x 0.5 x 9.5 传感器呼吸通口
显示精度 显示采样速度 错误显示 使用温度范围 保存温度范围 使用湿度范围 耐振动 耐冲击 耐水性 设定值保存 连接口径
±0.5%F.S.±1dig.(25℃时) 约4次/秒。 在压力显示用LED上显示 0~50℃ -20~60℃ 0~85%R.H. 10~55Hz.总振幅1.5mm.X.Y.Z方向各2小时 100m/s2、 X.Y.Z方向 显示部带保护盖为IP65、 无盖为IP40 不通电可保存10年 M5内螺纹(内置传感器型)

smc气动比例阀

smc气动比例阀

Smc气动比例阀兰州高压阀门新厂区开工建设市委书记出席开工奠基仪式首页>>产品中心>>比例式减压阀一、产品[固定比例式减压阀]的详细资料:产品名称:固定比例式减压阀产品特点:本厂生产的比例式减压阀,外形美观,质量可靠,比例准确,工作平稳.既减动压也减静压。

该阀利用阀体内部活塞两端不同截面积产生的压力差,改变阀后的压力,达到减压目的。

我厂减压阀的减压比例是:2:1,3:1,4:1,3:2,S 2等,亦可根据用户的要求设计特殊比例的减压阀.固定比例式减压阀,减压阀。

二、主要技术参数:适用介质水、气体适用温度≤90℃压力误差≤8%最小开启2:1 0.2MPa压力3:1 0.3MPO连接形式法兰、内螺纹主要零件阀体锡青铜不锈钢铸铁材料内件锡青铜不锈钢锡青铜或不锈钢三、比例式减压阀主要外形尺寸(法兰连接尺寸PNl.OMPa按GB4216.4—84标准):公称通径DN (mm)A125 11532 12440 13250 14065 15580 155100 200125 220150 230200 270订货须知:一、①比例式减压阀产品名称与型号②比例式减压阀口径③比例式减压阀是否带附件二、若已经由设计单位选定公司的比例式减压阀型号,请按比例式减压阀型号三、当使用的场合非常重要或环境比较复杂时,请您尽量提供设计图纸和详细参数,相关产品:WM341系列隔膜可调式减压阀波纹管式减压阀T44H/Y型波纹管减压阀YZ11X直接作用薄膜式水用减压阀直接作用薄膜式减压阀内螺纹活塞式蒸汽减压阀Y45H/Y型手动双座蒸汽减压阀Y945H/Y型电动双座蒸汽减压阀YB43X固定比例式减压阀高灵敏度蒸汽减压阀首页>>产品中心>>YB43X固定比例式减压阀一、产品[固定比比例式减压阀]的详细资料:产品型号:YB43X产品名称:固定比比例式减压阀产品特点:固定比比例式减压阀,比例式减压阀,减压阀二、YB43X固定比例式减压阀外形尺寸:公称通径DN lmmlA D325 232 115/12532 246 140/15040 256 150/15550 270 165/17565 306 185/20080 320 210/230100 340 240/265 125 400 275/300 150 429 310/350 200 358 355/400 三、YB43X固定比例式减压阀外形尺寸:型号公称压力PN(MPa)公称通径DN(mm)LYB43X-10T (B型) 1.050 8565 10280 122100 140125 160150 178200 230YB43x-16T (B型) 1.650 8565 10280 122100 140125 160150 178200 230四、YB43X固定比例式减压阀外形尺寸:订货须知:一、①YB43X固定比例式减压阀产品名称与型号②YB43X固定比例式减压阀口径③YB43X固定比例式减压阀是否带附件二、若已经由设计单位选定公司的YB43X固定比例式减压阀型号,请按YB43X固定比例式减压阀型号三、当使用的场合非常重要或环境比较复杂时,请您尽量提供设计图纸和详细参数,相关产品:WM341系列隔膜可调式减压阀波纹管式减压阀T44H/Y型波纹管减压阀YZ11X直接作用薄膜式水用减压阀直接作用薄膜式减压阀内螺纹活塞式蒸汽减压阀Y45H/Y型手动双座蒸汽减压阀Y945H/Y型电动双座蒸汽减压阀高灵敏度蒸汽减压阀铜阀门>>铜减压阀>>全铜比例式减压阀产品名称:全铜比例式减压阀产品型号:Y43X产品口径:DN50-200产品压力:0.6~10.0MPa产品材质:铸铁、铸钢、不锈钢等产品概括:生产标准:国家标准GB、机械标准JB、化工标准HG、美标API、ANSI、德标DIN、日本JIS、JPI、英标BS生产。

smc比例阀 分辨率设定

smc比例阀 分辨率设定

smc比例阀分辨率设定
该比例阀是一种按输入的电信号连续地、按比例地控制液压系统的液流方向、流量和压力的阀类。

普通阀只能通过预调的方式对液流的压力、流量进行定值控制。

但是当设备机构在工作过程中要求对液压系统的压力、流量参数进行调节或连续控制,例如,要求工作台在工作进给时按慢、快、慢连续变化的速度实现进给,或按一定精度模拟某个控制曲线实现旅力控制,普通液压阀则实现不了。

这时可以用比例阀对液压系统进行控制。

SMC VQZ-TF2Z496EN 三口气动阀说明书

SMC VQZ-TF2Z496EN 三口气动阀说明书
ISO 4413: Hydraulic fluid power - General rules relating to systems. IEC 60204-1: Safety of machinery - Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Robots and robotic devices - Safety requirements for industrial robots - Part 1: Robots.
VQZ100
VQZ200/300
Push type, Locking type (Tool required)
Contact SMC
Free
150 / 30
IP40 equivalent (DIN terminal: IP65 Note 5)) Refer to catalogue
Table 1.
Note 1) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is 1 MPa.
100V

Apparent
voltage [VA] AC
Note 1)
110V [115V] 200V 220V
[230V]
Surge voltage suppressor
Indicator Light
0.78 (With light: 0.81) 0.78 (With light: 0.87) 0.86 (With light: 0.89) 0.86 (With light: 0.87) [0.94 (With light: 0.97)] [0.94 (With light: 1.07)] 1.18 (With light:1.22) 1.15 (With light: 1.30) 1.3 (With light: 1.34) 1.27 (With light: 1.46) [1.42 (With light: 1.46)] [1.39 (With light: 1.60)]

SMC 电-气比例阀专用功率放大器VEA系列选项手册

SMC 电-气比例阀专用功率放大器VEA系列选项手册

检出
DC24V电源 电-气比例阀 外部指令信号 电位器 空号端子
对系统起安全保护作用。 _ + 继电器 PLC等
采用继电器或编程器, 由于断路, 电-气比例阀不动作,
带异常检出回路:VEA251
短路保护回路例
手动 复置 检出
与VEA250相同
继电器
空号端子
异常检出输出端子
在电流输出端子侧发生短路时, 电源便会立刻切断以防止损坏功 率放大器的输出回路。 可通过手动开关来重新开机或复置。
!"#$%&'()*
VEA
型号/规格
型号 功能 供应电压 耗电量 输出电流范围 VEA252 电-气比例阀阻抗 外部设定输入阻抗 外部设定输入电压 外部电位器 响应时间 高频振动频率调节范围(DITHER) 零点调整范围(NULL) 增益调整范围(GAIN) VEA250 电气线性度 阻抗波动 供应电压波动 温度波动 使用温度范围 相对湿度范围 耐振动 保存环境 VEA250 基本型, 只有驱动功能 VEA251 带异常检出回路 VEA252 有异常检出回路及反馈回路
带异常检出回路/VEA251
检测内容 输出形式 检出回路电源电压 输出电线及电源电线的断线 集电极开路输出/断线时OFF DC24V、 100mA
带反馈回路/VEA252
传感器的反馈电压 输入阻抗 前置放大器增益 积分动作时间(延迟调节) 微分动作时间 推荐范围0~5V(S.GAIN×0.1~×10)
DC24V(波动DC22V~26V) 约29W 0~1A 13~18.5‰(1A满刻度) 100k‰或以上 0~5V 10k‰(1/8W或以上):不提供 0.06s以下(1A、 95%) 120~180Hz(出厂时140Hz) 0~500mA(出厂时0mA) 在输入电压5V时/500mA~1A(出厂时1A) ±1%或以下(1A 满刻度) 在13~18.5‰时±1%以下(1A 满刻度) 在DC22V~26V时±1%以下(1A 满刻度) 在25℃±25℃时±2%以下(1A 满刻度) 0~50℃ 25~85% 2G(幅度 : 0.4mm、 50Hz)符合JISC0911 Ⅱ等级E4 无结露, 相对湿度 : 25~85%
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

产品名称:SMC比例阀说明书
SMCCORPORATION成立于1959年,总部设在日本东京都。

时至今日,SMC已成为世界级的气动元件研发、制造、销售商。

在日本本土更拥有庞大的市场网络,为客户提供产品及售后服务。

SMC 作为世界最著名的气动元件制造和销售的跨国公司,其销售网及生产基地遍布世界。

SMC产品以其品种齐全、可靠性高、经济耐用、能满足众多领域不同用户的需求而闻名于世。

在日本市场占有率已超过60%的SMC,通过分布于世界51个国家的海外子公司及分销商,将世界各国SMC产品的生产、销售连成一体,为用户提供直接、完善的服务。

相关文档
最新文档