10KV高压电缆型号
10KV高压电缆型号
10KV高压电缆型号:高压电缆价格:3、单位元/m高压电缆载流量:8.7/10(8.7/15)KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
8.7/10(8.7/15)KV/U型号YJV22、YJLV22、YJV23、YJLV23、JYV32,YJLV32、YJV33、YJLV33YJV、YJLV、YJY、YJLY 芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导体材质铜铝铜铝铜铝铜铝铜铝铜铝标称截面(mm2)253512014090110125155100120140170110135165205130155150180115135160190120145 5070165210130165180220140170205260160200245305190235215265160200225275175215 95120255290200225265300210235315360240280370430290335315360240270330375255290 150185330375225295340380260300410470320365490560380435405455305345425480330370 240300435495345390445500350395555640435500665765515595530595400455555630435490 400500565...450...520...450...7458555856808901030695810680765520595725825565650环境温度(℃)40254025 26/35KV电力电缆允许持续载流量26/35KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
/U26/35KV型号YJV、YJLV、YJY、YJLY、YJV、YJLV、YJY、YJLYYJLV23、JYV32,YJLV32、YJV33、YJLV33芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导芯材质铜铝铜铝铜铝铜铝铜铝铜铝标称截面(mm2)5070185230145190200250170190220270170210245305190235215265165200225275175215 95120280310215240300330230255330375255290370425285330315360240270330375255290 150185360400280310380425295330425485330380485555375430400455305345420475325370 240300470540365430490555380435560650435510650745505580525595400455555630430490 400500610...485...625...500...7608755956908701000680790680775525600720825565645 600 (10008001160920875685940740)环境温度(℃)40254025。
高压电缆型号与外径尺寸对照表(埋管必须资料)之欧阳家百创编
欧阳家百(2021.03.07)
序号
电缆型号
电缆外径(mm)
备注
1
YJV-6KV-3*16
35.90
2
YJV-10KV-3*25
40.50
3
YJV-10KV-3*35
45.40
4
YJV-10KV-3*95
57.10
5
YJV-10KV-3*240
72.90
6
VV3*240+1*120
3*95
230
212
194
173
3*120
265
245
223
200
3*150
305
282
257
230
3*185
355
328
299
268
3*240
420
338
354
317
备注:使用铝芯电缆的时候按照80%以上电流值计算。
10.2
2.958
-
3×95
3.4
2.7
56
4778
0.193
355
265
13.8
2.958
-
3×120
3.4
2.8
59
5595
0.153
290
300
17.4
2.958
-
3×150
3.4
2.9
63
6732
0.124
330
340
21.7
2.958
-
3×185
3.4
3
66
7954
0.0991
375
10kv电力电缆型号
10kv电力电缆型号10KV电力电缆是一种常用于输送高压电能的电缆产品。
它广泛应用于电力系统的中、高压输电线路中,承担着电能传输的重要任务。
10KV电力电缆的型号以及其相关特性,是电力系统设计和应用过程中的关键要素。
10KV电力电缆的型号分类繁多,根据国标标准可以分为多种不同型号,例如ZC-YJV、ZC-YJLV、ZC-YJY、ZC-YJLY等。
接下来,将介绍其中几种常见的型号及其特点。
首先,ZC-YJV电缆是一种铜芯交联聚乙烯绝缘聚氯乙烯护套的电力电缆。
它采用铜导体,绝缘材料为交联聚乙烯,外护套为聚氯乙烯,具有导电性好、绝缘性能稳定、抗电化学腐蚀等特点。
该型号电缆适用于室内或者地下直埋敷设,可用于输电、通信等领域的电力传输。
其次,ZC-YJLV电缆是一种铝芯交联聚乙烯绝缘聚氯乙烯护套的电力电缆。
与ZC-YJV相比,它采用铝导体替代了铜导体,其绝缘材料、护套材料与ZC-YJV相同。
铝导体具有重量轻、成本低等特点,适用于输电距离较长的地区,可以有效降低工程造价。
另外,ZC-YJY电缆是一种铜芯交联聚乙烯绝缘聚乙烯护套的塑料绝缘电力电缆。
它与前两种电缆不同之处在于外护套材料为聚乙烯,而不是聚氯乙烯。
这种电缆具有绝缘性能好、外观美观、耐候性强等特点,适用于吊装、移动设备、动力照明等场所。
最后,ZC-YJLY电缆是一种铝芯交联聚乙烯绝缘聚乙烯护套的塑料绝缘电缆。
它采用铝导体、聚乙烯绝缘和聚乙烯护套材料,适用于低压配电线路中。
这种电缆具有绝缘性能好、耐久性强等特点,常被用于城市住宅区、工厂以及商业建筑等地。
总的来说,10KV电力电缆的型号丰富多样,每种型号都有其独特的特点和适用范围。
在选择和应用时,需要根据实际需求和工程情况进行合理的选择。
电缆的材质、结构和性能直接关系到电力系统的稳定运行和安全性,因此在电力系统设计和建设中占据着重要的地位。
随着电力技术的不断进步,10KV电力电缆的发展和优化也将得到更多关注和研究,以满足越来越复杂的电力传输需求。
高压电缆型号大全
高压电缆型号大全一.交联聚乙烯绝6/6KV 8.7/10KV 8.7/15KV 26/35KV高压电缆,高压电缆价格,高压电缆规格型号细内容:YJV YJLV YJV22 YJLV22 高压聚氯乙烯绝缘电力电缆载流量型聚氯乙烯绝缘及护套电缆!缘电力电缆(普通高压电缆)0.6/1KV6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下YJVYJLV YJV22 YJLV22 YJV32 YJLV32二阻燃.交联聚乙烯绝缘电力电缆(阻燃高压电缆)0.6/1KV 6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下ZR-YJV ZR-YJLV ZR-YJV22 ZR-YJLV22 ZR-YJV32 ZR-YJLV32三.耐火交联聚乙烯绝缘电力电缆(耐火高压电缆)0.6/1KV 6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下NH-YJV NH-YJLV NH-YJV22 NH-YJLV22 NH-YJV32 NH-YJLV32。
高压电缆型号与外径尺寸对照表(埋管必须资料)
230
212
194
173
3*120
265
245
223
200
3*150
305
282
257
2303*1853来自5328299
268
3*240
420
338
354
317
备注:使用铝芯电缆的时候按照80%以上电流值计算。
7
VV3*185+1*95
53.30
8
VV3*120+1*70
44.01
9
VV3*95+1*50
39.52
10
VV3*35+1*16
27.08
11
VV3*25+1*16
24.91
YJV6/6KV、6/10KV交联电缆技术参数
YJV6/6KV、6/10KV交联聚乙烯绝缘聚氯乙烯护套电力电缆
导体标称截面
10.2
2.958
-
3×95
3.4
2.7
56
4778
0.193
355
265
13.8
2.958
-
3×120
3.4
2.8
59
5595
0.153
290
300
17.4
2.958
-
3×150
3.4
2.9
63
6732
0.124
330
340
21.7
2.958
-
3×185
3.4
3
66
7954
0.0991
375
380
1.082
3.501
10KV高压电缆型号之欧阳文创编
10KV高压电缆型号:高压电缆价格:3、单位元/m高压电缆载流量:8.7/10(8.7/15)KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
/U8.7/10(8.7/15)KV型号YJV、YJLV、YJY、YJLY、YJV22、YJLV22、YJV23、YJLV23、JYV32,YJLV32、YJV33、YJLV33YJV、YJLV、YJY、YJLY芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导体材质铜铝铜铝铜铝铜铝铜铝铜铝标称截面(mm2)253512014090110125155100120140170110135165205130155150180115135160190120145 5070165210130165180220140170205260160200245305190235215265160200225275175215 95120255290200225265300210235315360240280370430290335315360240270330375255290 150185330375225295340380260300410470320365490560380435405455305345425480330370 240300435495345390445500350395555640435500665765515595530595400455555630435490 400500565...450...520...450...7458555856808901030695810680765520595725825565650环境温度(℃)40254025 26/35KV电力电缆允许持续载流量26/35KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
/U26/35KV型号YJV、YJLV、YJY、YJLY、YJV22、YJLV22、YJV23、YJLV23、JYV32,YJLV32、YJV33、YJLV33YJV、YJLV、YJY、YJLY芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导芯材质铜铝铜铝铜铝铜铝铜铝铜铝标50185145200170220170245190215165225175称 截 面(mm2)70 230 190 250190 270 210 305 235 265 200 275 215 95 120 280 310 215240 300330230 255 330 375 255 290 370 425 285 330 315 360 240 270 330 375 255 290 150 185 360 400 280 310 380 425295 330 425 485 330 380 485 555 375 430 400 455 305 345 420 475 325 370 240 300 470 540 365 430 490 555380 435 560 650 435 510 650 745505 580 525 595 400 455 555 630 430 490400 500 610 ... 485 ... 625 ... 500 ... 760 875595690 870 1000 680790 680 775 525 600 720 825 565 645600 ... ......... 1000 800 1160 920 875 685 940 740环境温度 (℃)40254025。
10KV高压电缆型号
10KV高压电缆型号:高压电缆价格:3、单位元/m高压电缆载流量:8.7/10(8.7/15)KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
8.7/10(8.7/15)KV/U型号YJV22、YJLV22、YJV23、YJLV23、JYV32,YJLV32、YJV33、YJLV33YJV、YJLV、YJY、YJLY 芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导体材质铜铝铜铝铜铝铜铝铜铝铜铝标称截面(mm2)253512014090110125155100120140170110135165205130155150180115135160190120145 5070165210130165180220140170205260160200245305190235215265160200225275175215 95120255290200225265300210235315360240280370430290335315360240270330375255290 150185330375225295340380260300410470320365490560380435405455305345425480330370 240300435495345390445500350395555640435500665765515595530595400455555630435490 400500565...450...520...450...7458555856808901030695810680765520595725825565650环境温度(℃)40254025 26/35KV电力电缆允许持续载流量26/35KV交联聚乙烯绝缘电力电缆允许持续载流量额定电压U。
/U26/35KV型号YJV、YJLV、YJY、YJLY、YJV、YJLV、YJY、YJLYYJLV23、JYV32,YJLV32、YJV33、YJLV33芯数三芯单芯敷设空气中土壤中空气中土壤中单芯电缆排列方式导芯材质铜铝铜铝铜铝铜铝铜铝铜铝标称截面(mm2)5070185230145190200250170190220270170210245305190235215265165200225275175215 95120280310215240300330230255330375255290370425285330315360240270330375255290 150185360400280310380425295330425485330380485555375430400455305345420475325370 240300470540365430490555380435560650435510650745505580525595400455555630430490 400500610...485...625...500...7608755956908701000680790680775525600720825565645 600 (10008001160920875685940740)环境温度(℃)40254025。
高压电缆型号与外径尺寸对照表(埋管必须资料)
3×240
72
7929
435
435
-
3×300
77
11855
495
485
橡皮绝缘电力电缆
在空气中敷设的载流量(A)
电缆型号
(铜芯)
500V
XLV
XLF、XLHF、XLQ、XLQ20
18
19
24
25
3*4
32
34
3*6
40
44
3*10
57
60
3*16
76
81
3*25
101
107
3*35
124
131
3*50
Ω/km
A
A
KA
KA
KA
3×25
43
2132
120
125
-
3×35
45
2491
140
155
-
3×50
48
3091
165
180
-
3×70
52
3884
210
220
-
3×95
56
4778
355
265
-
3×120
59
5595
290
300
-
3×150
63
6732
330
340
-
3×185
3
66
7954
375
380
158
170
3*70
191
205
3*95
234
251
3*120
269
289
3*150
311
高压电缆选型依据
高压电缆选型依据高压电缆介绍:
1、6KV电缆
应用JXF(JBHF)-6KV。
全称:铜芯橡皮绝缘氯丁护套电机绕组引接电缆(电线)
应用JFEYH-10KV
备选厂家:上海南洋电缆有限公司、天津金山电线电缆股份有限公司供货期:由采购征询
高压电缆的分类:
1、单元输入
选型依据:功率单元输入电流
要求根据移相变压器输入视在功率选择。
功率单元输入电流=变压器总功率/绕组组数/辅助绕组电压/1.732
根据以上电流选择上一级电缆的输入
2、单元输出
星点电缆
目前电缆外径太粗,导致电流霍尔无法穿越。
故而选择10KV时应选择6KV同等级截面电缆
双层柜前后连接
双层柜柜前第五级单元与柜后第六级电缆的连接电缆
单元末端输出
最后一个功率单元输出至高压小室的电缆
选型依据:
根据功率单元电流等级选择。
如果偏差过大宜可根据实际情况酌情处理。
3、柜间互连
变压器柜电源输入
选型依据:
移相变压器的总功率/高压侧电压等级/1.732
单元柜电源输出
选型依据:
根据功率单元电流等级选择。
因牵扯电压降低,如果现场电缆过长应考虑加大一级。
此种电缆的长度应根据自动、手动以及自制与外协柜的具体尺寸加以修整。
最好建立出电子表格加以选择(后续)
要求把名称端头的尺寸
名称的尺寸。
高压电缆型号说明及用途
6/6KV 8.7/10KV 8.7/15KV 26/35KV高压电缆,高压电缆价格,高压电缆规格型号细内容:YJV YJLV YJV22 YJLV22 高压聚氯乙烯绝缘电力电缆载流量型聚氯乙烯绝缘及护套电缆!一.交联聚乙烯绝缘电力电缆(普通高压电缆)0.6/1KV 6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下YJV YJLV YJV22 YJLV22 YJV32 YJLV32二阻燃.交联聚乙烯绝缘电力电缆(阻燃高压电缆)0.6/1KV6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下ZR-YJV ZR-YJLV ZR-YJV22 ZR-YJLV22 ZR-YJV32 ZR-YJLV32三.耐火交联聚乙烯绝缘电力电缆(耐火高压电缆)0.6/1KV6/6KV 8.7/10KV 8.7/15KV 26/35KV1.产品标准:GB12706.3-20022.使用特性:该产品适用于交流额定电压35KV及以下供输配电能固定廒设线路用,电缆导体的最高长期工作温度90度,短路时(最长时间不超过5S),电缆导体最高温度不超过250度。
3.规格型号:35KV及以下NH-YJV NH-YJLV NH-YJV22 NH-YJLV22 NH-YJV32 NH-YJLV32常见电缆型号说明及用途型号名称用途铜芯NA-YJV,NB-YJV,交联聚乙烯绝缘聚氯乙烯护套A(B)类耐火电力电缆可敷设在对耐火有要求的室内、隧道及管道中。
10~110kV高压电缆载流量、电缆重量和电缆外径
10~110kV高压电缆载流量、电缆重量和电缆外径10~35kV单芯电缆载流量:根据表格,我们可以看到3.6/6-12/20KV单芯交联聚乙烯绝缘电力电缆的连续负荷载流量(A)。
不同型号的电缆排列方式和敷设方式也有所不同。
电缆的标称截面和敷设环境也会影响其载流量。
210kV三芯电缆载流量:此处缺失内容,无法进行编辑整理。
310kV电缆外径:此处缺失内容,无法进行编辑整理。
435kV电缆外径:此处缺失内容,无法进行编辑整理。
110kV电缆载流量:此处缺失内容,无法进行编辑整理。
110kV电缆外径:此处缺失内容,无法进行编辑整理。
交联聚乙烯绝缘电力电缆:该类型电缆的导体最高额定温度为90℃。
在短路情况下(最长持续时间为5秒),电缆的温度应不超过250℃。
当敷设电缆时,若环境温度低于一定温度,需要进行预先加温。
此外,电缆敷设时的最小弯曲半径应不小于电缆外径的10倍。
对于铠装电缆,其最小弯曲半径应不小于电缆的12倍。
而五芯电缆的最小弯曲半径应不小于电缆外径的15倍。
此类电缆执行标准为额定电压35KV及以下交联聚乙烯绝缘电力电缆执行标准GB.3-91(等效采用IEC502-1983)。
20-26/35KV单芯交联聚乙烯绝缘电力电缆的负荷载流量(A)取决于型号、排列方式、敷设方式和标称截面。
该电缆型号包括YJV、YJLV、YJY和YJLV,排列方式有三角形(相互接触)和扁平形(相邻间距等于电缆外径),敷设方式包括在空气中、直埋和土壤中。
标称截面为mm2,材料为XXX。
改写:单芯交联聚乙烯绝缘电力电缆的负荷载流量(A)受到型号、排列方式、敷设方式和标称截面的影响。
该电缆有YJV、YJLV、YJY和YJLV型号,可采用三角形(相互接触)或扁平形(相邻间距等于电缆外径)排列方式,并可在空气中、直埋或土壤中敷设。
标称截面以mm2为单位,材料为XXX。
下面的数字列出了不同标称截面下的负荷载流量(A):502、702、953、1203、1504、1855、2406、3007、4008、5009、、、、.改写:以下数字表示不同标称截面下的负荷载流量(A):502、702、953、1203、1504、1855、2406、3007、4008、5009、、、和.明显有问题的段落已被删除。
高压电缆型号与外径尺寸对照表(埋管必须资料)
43
2132
120
125
-
3×35
45
2491
140
155
-
3×50
48
3091
165
180
-
3×70
52
3884
210
220
-
3×95
56
4778
355
265
-
3×120
59
5595
290
300
-
3×150
63
6732
330
340
-
3×185
3
66
7954
375
380
-
3×240
72
7929
电缆型号与外径尺寸对照表(埋管必须资料)之南宫帮珍创作
序号
电缆型号
电缆外径(mm)
备注
1
YJV-6KV-3*16
2
YJV-10KV-3*25
3
YJV-10KV-3*35
4
YJV-10KV-3*95
5
YJV-10KV-3*240
6
VV3*240+1*120
7
VV3*185+1*95
8
VV3*120+1*70
30℃
35℃
40℃
3*16
75
69
63
56
3*25
100
92
84
75
3*35
125
115
105
94
3*50
155
143
130
117
3*70
190
170
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
10KV高压电缆型号:
高压电缆价格:
3、单位元/m
高压电缆载流量:
8.7/10(8.7/15)KV交联聚乙烯绝缘电力电缆允许持续载流量
额定电压U。
/U8.7/10(8.7/15)KV
型号
YJV22、YJLV22、YJV23、
YJLV23、JYV32,YJLV32、
YJV33、YJLV33
YJV、YJLV、YJY、YJLY 芯数三芯单芯
敷设
空气中土壤中空气中土壤中
单芯电缆
排列方式
导体材质铜铝铜铝铜铝铜铝铜铝铜铝
标称截面(mm2)
25
35
120
140
90
110
125
155
100
120
140
170
110
135
165
205
130
155
150
180
115
135
160
190
120
145 50
70
165
210
130
165
180
220
140
170
205
260
160
200
245
305
190
235
215
265
160
200
225
275
175
215 95
120
255
290
200
225
265
300
210
235
315
360
240
280
370
430
290
335
315
360
240
270
330
375
255
290 150
185
330
375
225
295
340
380
260
300
410
470
320
365
490
560
380
435
405
455
305
345
425
480
330
370 240
300
435
495
345
390
445
500
350
395
555
640
435
500
665
765
515
595
530
595
400
455
555
630
435
490 400
500
565
...
450
...
520
...
450
...
745
855
585
680
890
1030
695
810
680
765
520
595
725
825
565
650
环境温度
(℃)
40254025
26/35KV电力电缆允许持续载流量
26/35KV交联聚乙烯绝缘电力电缆允许持续载流量
额定电压U。
/U26/35KV
型号YJV、YJLV、YJY、YJLY、YJV、YJLV、YJY、YJLY
YJLV23、JYV32,YJLV32、
YJV33、YJLV33
芯数三芯单芯
敷设
空气中土壤中空气中土壤中
单芯电缆
排列方式
导芯材质铜铝铜铝铜铝铜铝铜铝铜铝
标称截面(mm2)
50
70
185
230
145
190
200
250
170
190
220
270
170
210
245
305
190
235
215
265
165
200
225
275
175
215 95
120
280
310
215
240
300
330
230
255
330
375
255
290
370
425
285
330
315
360
240
270
330
375
255
290 150
185
360
400
280
310
380
425
295
330
425
485
330
380
485
555
375
430
400
455
305
345
420
475
325
370 240
300
470
540
365
430
490
555
380
435
560
650
435
510
650
745
505
580
525
595
400
455
555
630
430
490 400
500
610
...
485
...
625
...
500
...
760
875
595
690
870
1000
680
790
680
775
525
600
720
825
565
645 600 (10008001160920875685940740)
环境温度
(℃)
40254025。