9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 99.2 4 - Plex Grouped Motor Control
Starter and Feeder Units
Table 9-1. NEMA - Freedom Combination Starters ᕃ ᕄ
NEMA
Size
Max. H.P.
@ 575V ᕆ
Unit Size ᕅ
Non-reversing Reversing
05Single Double
110Single Double
225Single Double
350Doubleᕈ
4100Doubleᕈ
Table 9-3. Feeder Modulesᕃ ᕉ
Amps
Rating
Unit Size ᕅ
2-Pole3-Pole Dual 2-Pole
or 3-Pole
15-30Single Single Single
40-60Single Single Single
70-100Single Single Single
125-150Single Single-
175-200Single Single-
ᕃAvailable in Circuit breaker or Fusible Disconnect configurations. Fuses are not included. HRC fuse clips are available on request.
ᕄStarters do not include overload heaters - order separately. Select 1 carton of 3 overload heaters from Page 13.4.
ᕅSingle width modules are 8” wide. Double modules are 16” wide.
ᕆFor other Voltage and Horsepower ratings consult Eaton.
ᕇRatings based on Standard Duty and using a 1.15 service factor.
ᕈConsult Eaton.
ᕉAvailable in 240V or 600V design.
ᕊBreakers are not included.
Table 9-4. Lighting Panelboards ᕊ
Circuit
Space
Unit Size ᕅ
PRL-1PRL-2
18 cct.Double Double
24 cct.Double Double
All units are available in Type 1 or Type 12 enclosures with individual module doors. For multiple 4-Plex units, splitter troughs are available in 200A and 400A.
Please also refer to Publication No. SA.03A.01.S.K for additional information.
Cover Control . . . . . . . . . . . . . . . . . . . . . . . .Page 9.3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 9.3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .Page 9.4 Table 9-2. IT. Reduced Voltage Combination Starters ᕃ
Max
FLA ᕇ
Max. H.P.
@ 575V ᕆ
Unit Size ᕅ
37A30Double
66A50Double
105A75Double
135A100Double
2Enclosed Control Product Guide PG03300002K—October 2010 www.eatoncanada.ca
Enclosed Control Product Guide PG03300002K—October 2010 www.eatoncanada.ca 3
999999999999999999999999999999
Table 9-5. 4-Plex Accessories ᕃ
ᕃConsult Eaton for other accessories available.

Blank door is required when a starter or a feeder module is not used.
DEVICE FUNCTION BLANK DOORS ᕄTYPE 1TYPE 12NEUTRAL SPLITTER PAD
4 - WIRE SYSTEM CONTROL TRANSFORMER
SIZE 0-1 OR B-F SIZE 2 OR G-J SIZE 3 OR K-L SIZE 4
PUSHBUTTONS
STOP/START FWD-REV-STOP SELECTOR SWITCHES
HAND-OFF-AUTO
ON-OFF FWD-OFF-REV
PILOT LIGHTS
FULL VOLTAGE TYPE TRANSFORMER TYPE AUXILIARY CONTACTS
1 - N/O & 1 - N/C
2 - N/O 2 - N/C
MISCELLANEOUS
LAMACOID NP - 1”x2”TERMINAL BLOCK (1 PT.)
AUXILIARY RELAY (4P)PRIMARY FUSING DOOR SWITCH ELAPSED TIME METER
9.3
4 - Plex Grouped Motor Control
Accessories
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 99.4 4 - Plex Grouped Motor Control
Dimensions and Order Entry
4Enclosed Control Product Guide PG03300002K—October 2010 www.eatoncanada.ca
Enclosed Control Product Guide PG03300002K—October 2010 www.eatoncanada.ca 5
999999999999999999999999999999
9.5
4 - Plex Grouped Motor Control
Dimensions and Order Entry
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 99.6 4 - Plex Grouped Motor Control
Dimensions and Order Entry
6Enclosed Control Product Guide PG03300002K—October 2010 www.eatoncanada.ca。