ABB塑壳FORMULA 中文选型手册
3 ABB选型价格查询手册 转换开关 低压产品
![3 ABB选型价格查询手册 转换开关 低压产品](https://img.taocdn.com/s3/m/ec7161de26fff705cc170a67.png)
连接装置 - 接线端子 - 螺钉卡箍连接、弹簧连接、ADO绝缘移位连接...............................2/60 - 工业连接器........................................................................................................2/69
ABB塑壳断路器 Formul A塑壳断路器选型手册
![ABB塑壳断路器 Formul A塑壳断路器选型手册](https://img.taocdn.com/s3/m/1ca0400f79563c1ec5da7124.png)
• No nominal performance derating for use up to an altitude of 6562 ft. Above 6562 ft, the properties of the atmosphere (composition of the air, dielectric strength, cooling power and pressure) change, having an impact on the main parameters which define the circuit breaker. The table below gives the changes to the main performance parameters.
• Circuit breaker weights
Weights Circuit breaker 1 pole Circuit breaker 2 poles Circuit breaker 3 poles
A1 [Lbs] 0.54 1.04 1.54
A2 [Lbs] 0.82 1.61 2.43
• FORMULA circuit breakers can be used in ambient with a temperature between -25°C to 70°C (-13°F to 158°F) and stored in a room with atmospheric temperature between -40°C to 70°C (-40°F to 158°F).
Altitude
Rated service voltage, Ue Rated uninterrupted current
abb断路器 参数
![abb断路器 参数](https://img.taocdn.com/s3/m/4497084e53ea551810a6f524ccbff121dd36c59b.png)
abb断路器参数(原创实用版)目录1.ABB 断路器概述2.ABB 断路器型号大全3.如何查看 ABB 断路器型号参数4.ABB 断路器的应用范围5.结束语正文ABB 断路器是一种用于保护电路和设备的重要元件,它可以在电路中断路、过载和短路等情况下,及时切断电源,防止设备受到损坏。
ABB 作为全球 500 强企业,其生产的断路器种类繁多,覆盖了从微型断路器到高分断能力的塑壳、空气断路器的各个领域。
一、ABB 断路器型号大全ABB 断路器的型号大全包括以下几个框架:1.Emax2:适用于配电系统的万能式断路器。
2.Xtmax:适用于工业应用的塑壳断路器。
3.Formula:适用于住宅和商业建筑的微型断路器。
4.Tmax:适用于电力系统的空气断路器。
5.Sh200 和 S200:适用于低压断路器的微型断路器。
二、ABB 断路器型号参数怎么看想要了解 ABB 断路器的型号参数,可以从以下几个方面入手:1.额定电压:指断路器正常工作时,系统的额定线电压。
这是断路器的标称电压,应能保持在这一电压的电力系统中使用,最高工作电压可超过额定电压 15%。
2.额定电流:指断路器在规定使用和性能条件下可以长期通过的最大电流。
当额定电流长期通过高压断路器时,其发热温度不应超过国家标准中规定的数值。
3.额定短路开断电流:指断路器在短时间内能够安全切断的最大电流。
三、ABB 断路器的应用范围ABB 断路器广泛应用于工业、住宅、商业建筑、电力系统等领域,为电路提供可靠的保护。
其产品性能稳定,质量可靠,得到了全球用户的认可。
总之,ABB 断路器作为全球知名品牌的断路器产品,无论从型号、参数还是应用范围上,都展现出了强大的实力。
ABB低压电器元件选型手册(可编辑)
![ABB低压电器元件选型手册(可编辑)](https://img.taocdn.com/s3/m/5f2372c53b3567ec112d8a06.png)
选用手册ABB低压电器元件1SXF100200L2006 10-2006低压产品低压产品20062006低压电器元件选用手册目录页1.断路器1空气断路器- New E ............................................................................... 1/ 1-4塑壳断路器- T ....................................................................................... 1/5-8塑壳断路器- Iso................................................................................... 1/9- 10漏电保护组件/漏电保护继电器........................................................................ 1/ 11双电源自动切换装置- DPT ............................................................................. 1/ 12配电智能化元件-IPD ............................................................................... 1/ 13- 142.工控产品软起动器..................................................................................................... 2/ 1-7 2接触器........................................................................................................... 2/8手动电机起动器- MS系列........................................................................... 2/9- 11短路保护电器和接触器及热继电器的配合.......................................................... 2/ 12电动机保护.............................................................................................. 2/ 13- 17指示装置.................................................................................................. 2/ 18- 19接线端子.................................................................................................. 2/20-2 1电子产品和继电器..................................................................................... 2/22-243.开关及熔断器组3开关熔断器组- PowerLine ............................................................................... 3/ 1负荷开关- Sw itchLine .................................................................................. 3/2-3熔断器开关- Easy Line .................................................................................... 3/44.终端配电保护产品4建筑电器元件............................................................................................... 4/ 1-8建筑用接触器- ESB 导轨安装........................................................................ 4/9电涌保护器- OV R ......................................................................................... 4/ 10优化脉冲提前放电避雷针- OPR ...................................................................... 4/ 115.箱体终端配电箱- A CM/A CP/A CF 系列..................................................................... 5/ 1 5三相配电箱- SDB系列................................................................................. 5/2-3动力配电箱- MDS系列................................................................................. 5/4-56.电网质量产品6电容器专用接触器........................................................................................... 6/ 1无功补偿控制器件........................................................................................ 6/2-3有源动态滤波器........................................................................................... 6/4-57.断路器保护配合表7断路器保护配合表...................................................................................... 7/ 1- 10●因产品技术不断改进,所有数据应以本公司最新确认为准。
ABB电子版选型手册2011-3
![ABB电子版选型手册2011-3](https://img.taocdn.com/s3/m/5d0a660803d8ce2f00662388.png)
ABB微断选型
隔离开关 E200
额定电流 (A) 16 32 45 63 80 100 125 1 E201-16 E201-32 E201-45 E201-63 E201-80 E201-100 E201-125 极数 2 E202-16 E202-32 E202-45 E202-63 E202-80 E202-100 E202-125 3 E203-16 E203-32 E203-45 E203-63 E203-80 E203-100 E204-16 E204-32 E204-45 E204-63 E204-80 E204-100 4
外形
C 特性:用于感性负荷和高感性照明系统的线路提供保护 电流(A) 1P+N(电子式) 2P(电子式) 3P(电子式) 6 10 16 20 25 32 40 50 63 GSH201-C6 GSH201-C10 GSH201-C16 GSH201-C20 GSH201-C25 GSH201-C32 GSH201-C40 GSH201-C50 GSH201-C63 GSH202-C6 GSH202-C10 GSH202-C16 GSH202-C20 GSH202-C25 GSH202-C32 GSH202-C40 GSH202-C50 GSH202-C63 GSH203-C6 GSH203-C10 GSH203-C16 GSH203-C20 GSH203-C25 GSH203-C32 GSH203-C40 GSH203-C50 GSH203-C63
分断
6KA
D特性:对高感性负荷和有较大冲击电流产生的配电系统提供线路保护 电流(A) 1P+N(电子式) 2P(电子式) 3P(电子式) 6 GSH201-D6 GSH202-D6 GSH203-D6 10 GSH201-D10 GSH202-D10 GSH203-D10 16 GSH201-D16 GSH202-D16 GSH203-D16 20 GSH201-D20 GSH202-D20 GSH203-D20 25 GSH201-D25 GSH202-D25 GSH203-D25 32 GSH201-D32 GSH202-D32 GSH203-D32 40 GSH201-D40 GSH202-D40 GSH203-D40 50 GSH201-D50 GSH202-D50 GSH203-D50 63 GSH201-D63 GSH202-D63 GSH203-D63 注:30mA漏电为常规产品,其他10mA,100mA,300mA请注明。
ABB选型资料
![ABB选型资料](https://img.taocdn.com/s3/m/6f6abeb0caaedd3382c4d3ba.png)
ABB分销商培训教材技术部分内容简介1产品选用基本技术参数2常用产品选用注意事项3产品大全及分类1元件选用基本技术参数本章节列出的是选用每种元件必须的基本技术参数,具体参数选择请参阅《ABB 低压电器元件选用手册》及相关样本。
断路器 1.1 1-7Emax空气断路器 1.1.1•框架•框架电流•分断能力•额定电流•脱扣器•极数•安装方式•附件控制电压例如:E1 B 12 PR111/P-LI R1250 3P WHR框架分断能力框架电流脱扣器额定电流极数安装方式技术参数代号解释框架: E1 E1 Iu = 800~1250AE1 Iu = 800~1250AE2 Iu = 1250~2000AE3 Iu = 1250~3200AE4 Iu = 3200~4000AE6 Iu = 3200~6300A分断能力: B B: 40kAB: 40kAN: 65kAS: 75kAH: 100kAV: 150KAL: 130KA框架电流:12 1250A(E1,1250A--E6,6300A)脱扣器:PR111/P-LI PR111/P-LI PR111脱扣器,二段保护PR111/P-LI PR111脱扣器,二段保护PR111/P-LSI PR111脱扣器,三段保护PR111/P-LSIG PR111脱扣器,四段保护PR112/P-LSI PR112脱扣器,三段保护PR112/P-LSIG PR112脱扣器,四段保护PR112/PD-LSI PR112脱扣器,三段保护带对话单元PR112/PD-LSIG PR112脱扣器,四段保护带对话单元PR113/P-LSIG PR113脱扣器,四段保护PR113/PD-LSIG PR113脱扣器,四段保护带对话单元额定电流:R1250 1250A(E1,250A--E6,6300A)极数: 3P 3极(3或4极可选)安装方式:WHR W:抽出式(W:抽出式F:固定式)HR:水平后接线HR 水平后接线VR 垂直后接线F 延伸接线FL 端面接线(固定式无)附件控制电压:需要注明控制电压附件---YO,YC,YU,MIsomax塑壳断路器 1.1.2 •框架•框架电流•额定电流•分断能力•脱扣器(TM热敏电磁脱扣器型无须提供)•极数•安装方式•附件控制电压例如:TM热敏电磁脱扣器型:S2 S – 160 / R125 3P FFC框架分断能力框架电流额定电流极数安装方式技术参数代号解释框架: S2 S2S1 I=125S2 I=160S3 I=160,250S5 I=400,630S6 I=630,800分断能力:S SS1: B / N KA数值请查样本S2: B / N / S KA数值请查样本S3: N / H / L KA数值请查样本S5: N / H / L * KA数值请查样本S6: N / S / H / L KA数值请查样本框架电流:160A 参阅框架额定电流:R125 125AS1-125, 10A----S6-800, 800A极数:3P 3极(3或4极可选)安装方式:FFC F: 固定式F: 固定式P: 插入式(S6/S7不适用)W: 抽出式(S1/S2不适用)FC: 铜电缆前接线F: 前接线EF: 加长前接线ES: 加长扩展前接线FC: 铜电缆前接线R: 螺纹后接线RC: 铜/铝后接线附件控制电压:需要注明控制电压附件---YO,YC,YU,M框架 分断能力 框架电流 脱扣器 额定电流 极数 安装方式微处理器脱扣器型:S4 N – 250 / In125 LSIG 3P FFC技术参数 代号 解释框架:S4S4 I=160,250 S4 I=160,250 S5 I=400,630 S6 I=630,800 S7 I=1250,1600S8 I=2000, 2500, 3200分断能力: N NS4: N / H / L KA 数值请查样本 S5: N / H / L KA 数值请查样本 S6: N / S / H / L KA 数值请查样本 S7: S / H / L KA 数值请查样本 S8: H / V (新品)KA 数值请查样本框架电流: 250 参阅框架 额定电流: R125 125AS4-160, 100A----S6-800, 3200A脱扣器: LSIG LSIG: 长延迟+短延迟+瞬动+接地故障I: 短路瞬动 LI: 长延迟+瞬动LSI: 长延迟+短延迟+瞬动LSIG: 长延迟+短延迟+瞬动+接地故障 LRIU: 长延迟+堵转+瞬动+断相或相不平衡( PR010/K,PR212/D,PR212/T 参见样本 )极数: 3P 3极(3或4极可选)安装方式: FFC F: 固定式F: 固定式P: 插入式(S6/S7不适用) W: 抽出式(S1/S2不适用)FC: 铜电缆前接线 F: 前接线 EF: 加长前接线 ES: 加长扩展前接线 FC: 铜电缆前接线 R: 螺纹后接线 RC: 铜/铝后接线 附件控制电压: 需要注明控制电压附件---YO ,YC ,YU ,MIsomax塑壳断路器限流型 1.1.3 •框架•框架电流•额定电流•分断能力•极数•安装方式附件控制电压例如:技术参数代号解释S3 X - 125 / R80 3P FEF框架分断能力框架电流额定电流极数安装方式框架: S3 S3S2 I=1~100 分档S3 I=125,200S4 I=250S6 I=400,630分断能力:X XS2X分断能力70KA; S3X,S4X,S6X分断能力200KA框架电流:125 参阅框架额定电流:R80 80AS2X-80: 1~80(19档), 3P,单磁 (参见样本)S2X-100:1~100(16档), 3P, 参见样本S3X-125: 32,50,80,100,125S3X-200: 125,160,200S4X-250: 100,160,250S6X-400: 320,400S6X-630: 630极数:3P 3极(3或4极可选)安装方式:FEF F: 固定式F: 固定式P: 插入式(S6)W: 抽出式(S1/S2不适用)EF: 加长前接线F: 前接线EF: 加长前接线ES: 加长扩展前接线FC: 铜电缆前接线R: 螺纹后接线RC: 铜/铝后接线附件控制电压:需要注明控制电压附件---YO,YC,YU,M一体化剩余电流断路器 1.1.4•框架•框架电流•额定电流•极数•安装方式•排列•附件控制电压例如:S2 N – 160 / R125 4P FFC +RC212/ 2V框架分断能力框架电流额定电流极数安装方式脱扣器技术参数代号解释框架、分断能力、框架电流:S2N-160只有两种S2N-160,S3N-250额定电流:R80 80AS2-160: 12.5,16,20,25,32,40,50,63,80,100,125,160S3-250: 32,40,50,63,80,100,125,160,200,250S3及以下磁脱扣固定为10倍,非标可有5倍或单磁. 极数:4P 4P安装方式:FFC F: 固定式F: 固定式FC: 铜电缆前接线F: 前接线(S3N)FC: 铜电缆前接线(S2N)排列:V V:垂直安装V:垂直安装,H:水平安装附件控制电压:需要注明控制电压附件---YO,YC,YU,M切换回路数回路数额定电流额定电流 安装方式 电源自动切换装置1.1.5DPT• 切换回路数 • 额定电流例如:DPT / SE1600技术参数代号 解释 切换回路数: SESE 双电源切换,TE 三电源切换 额定电流:1600 1600A 主回路电流Isomax 低压塑壳断路器配合剩余电流保护继电器1.1.6RC212• 框架电流• 安装方式例如:RC212 / 2 / 垂直安装技术参数 代号解释额定电流: 2(代码) 配S2-160/4P: 选 2 配S2-160/4P: 选 2 配S3-250/4P: 选 3 安装方式: 垂直安装 垂直安装与断路器叠装: 垂直安装 与断路器并装: 水平安装RCD• 剩余动作电流例如:剩余动作电流互感器内径主回路电流极数辅助触头数量控制电压RCD 0.03技术参数代号解释剩余动作电流: 0.03 30 mA剩余动作电流:0.03 - 0.1 - 0.3 -0.4 - 1A剩余电流保护继电器 1.1.7 RCQ•互感器内径例如:RCQ Ф110技术参数代号解释互感器内径: 110mm Φ110 mmΦ60 mm互感器内径Φ110 mm互感器内径工控产品及接线附件 1.2 1-3接触器系列 1.2.1接触器 1.2.1a •主回路电流•控制电压(交、直流)•极数•辅助触头数量例如:A30 – 30 - 10 控制电压ac220V技术参数代号解释主回路电流: 30 30A极数: 30 3常开前一位代表常开,后一位代表常闭,数字为数量辅助触头数量10 一常开前一位代表常开,后一位代表常闭,数字为数量控制电压(交、直流)ac220V 交流220VTA热过载继电器 1.2.1b •热脱扣电流•轻重载(450以上)例如:T450 DU 400主回路电流轻重载脱扣电流技术参数代号解释主回路电流: 450 450A轻重载:DU DU普通DU普通SU重载中间继电器 1.2.1c •触点数、主触点组合方式(常开、常闭)•控制电压、交、直流操作例如:N 63 E 控制电压ac220V触点数、主触点组合方式控制电压、交、直流操作技术参数代号解释触点数、主触点组合方式:63 6常开,3常闭前一位代表常开,后一位代表常闭,数字为数量控制电压、交、直流操作:控制电压ac220V额定电流触点数、主触点组合方式控制电压、交、直流操作框架电流和分断能力额定电流ESB接触器 1.2.1d •额定电流•主触点组合方式(常开、常闭)•控制电压、交、直流操作•灯具应用请参阅样本例如:ESB 63 - 31 控制电压ac220V技术参数代号解释额定电流:63 63A20 对AC1/AC7a负载24 对AC1/AC7a负载40 对AC1/AC7a负载63 对AC1/AC7a负载触点数、主触点组合方式:31 6常开,3常闭ESB20: 可选: 20, 02, 11ESB24: 可选: 40, 04, 22, 31, 13ESB40: 可选: 40ESB63: 可选: 40前一位代表常开,后一位代表常闭,数字为数量控制电压、交、直流操作:控制电压ac220V灯具应用:请参阅样本电动机起动器 1.2.2 •框架电流和分断能力•热脱扣电流例如:MS 325 - 20框架电流和分断能力:325 MS325 50KA,0.1-25AMS325 50KA,0.1-25AMS450 50kA,16~50AMS451 50KA,16~50AMS495 50KA,40~100AMS496 100KA,40~100AMS497 100KA,16~100A额定电流20 20APSS、PST、PSTB软启动器 1.2.3 •电机额定电流(结合功率考虑)•负载类型(重、轻载)•控制电源电压例如:PSS - 18/30电机额定电流技术参数代号解释电机额定电流:18/30 18A外接法/30A内接法(PSS)负载类型(重、轻载):参阅样本控制电源电压:参阅样本开关及熔断器设备 1.3 1-3开关熔断器组 1.3.1 OS、OESA•额定电流•极数例如:OESA 250 D3PL 3P额定工作电流极数额定工作电流:250 250A极数:3P 3极负荷开关/隔离开关 1.3.2 OT、OETL•额定电流•极数例如:OETL 250 K3 3P额定工作电流极数技术参数代号解释额定工作电流:250 250A极数:3P 3极Easyline熔断丝切换隔离开关 1.3.3 XLP三极•额定电流例如:XLP 00额定电流技术参数代号解释额定电流:00 160A按照样本根据电流选择型号线路保护装置 1.4极数脱扣特性额定电流极数脱扣特性额定电流数量剩余电流动作电流微型断路器 1.4.1 •额定电流•极数(最后位数字为可选项,1为1极,2为2极…依此类推,例如S261)•分断能力•脱扣特性(B、C、D、K等)例如:S 261 – C 20技术参数代号解释极数: 261 1极最后位数字为可选项,1为1极,2为2极…依此类推脱扣特性: C CB、C、D、K、Z根据样本,由不同系列不同电流而不同额定电流:20 20A根据样本,由不同系列有不同电流范围过电流保护电磁式剩余电流动作断路器 1.4.2DS250S•额定电流•极数(最后位数字为可选项,1为1极,2为2极…依此类推,例如DS252) •分断能力•脱扣特性(B、C)•剩余电流动作电流例如:DS253S-C 40 / 0.03技术参数代号解释极数:DS253 3极极数脱扣特性额定电流数量剩余电流动作电流最后位数字为可选项,2为2极…依此类推(无1极)脱扣特性: C CB、C两种额定电流:40 40A根据样本,由不同系列有不同电流范围剩余电流动作电流:0.03 30mADS9•额定电流•极数(最后位数字为可选项,1为1极,2为2极。
ABB SACE 三步选型过程的ArTu PB面板板类目目录说明书
![ABB SACE 三步选型过程的ArTu PB面板板类目目录说明书](https://img.taocdn.com/s3/m/43b0107d86c24028915f804d2b160b4e767f812c.png)
1STC802005D0201ArTu PBPanelboardTechnical catalogueIndexThree-step selection process (2)PanelboardGeneral information (4)Selection (5)Custom panelboardGeneral information (6)Selection (7)Custom pan assemblyGeneral information (8)Selection (9)Incoming selection kit (10)MCCB Outgoing breaker selection (11)AccessoriesMCCB (13)Panelboard (14)Custom panelboard and pan assembly (15)In-depth technical information (16)Overall dimensions (20)Lifting and overhead travelling (23)List of codes (24)ABB SACE1ArTu PB Panelboard Three-step selection process3ABB SACE STEP 1Select the fixed Panelboard required from page 5or Select the Custom Panelboard required from page 7or Select the Custom Pan Assembly required from page 9STEP 2Select the incoming device and the inner door required from page 10STEP 3Select the outgoing device required from page 11Remember4ABB SACEArTu PB PanelboardGeneral informationThe ArTu distribution switchboards are enriched by the new ArTuPB Panelboard series, for applications up to 800 A incomer withoutgoing ways up to 250 A, which complete now the ABB offer.The ArTu PB panelboard is extremely sturdy, thanks to the new design in metalwork system.The ArTu PB panelboard is available as wall mounted as standard,and in three configurations of 6, 12 and 18 outgoing ways, withthe option of building your own custom panelboard.The new system allows you to fit T1 and T3 three or four pole and the single pole MCCB off the same copper system using the all Technical characteristicsCompliance with Standards CEI EN 60439-1Rated service voltage - Ue up to 690 V Rated insulation voltage - Ui up to 1000 V Rated frequency 50-60 Hz Rated impulse withstand voltage - Uimp 8 kV Rated current - Inup to 800 A Rated short-circuit short-timeWithstand current - Icw up to 50 kA Rated short-circuit peak current - Ipk up to 110 kA IP degree of protection 43 with doornew plug in system designed by ABB.An extension box is available with a width of 390mm which can be fitted on both sides of the structure.There is also an option of adding a top and bottom extension box;metering extension boxes are also available.Trunking has been fitted vertically behind each row of MCCBs to allow cabling from SR’s, UV’s and AUX contacts to be channelled away. As standard the panelboard is fitted with a plain door but,as an option, it can be fitted with a glazed one.5ABB SACE ArTu PB Panelboard SelectionSTEP 1Select the fixed capacity Panelboardrequired from the table below.Panelboard fixed capacityOrder code* T3 4 pole Panelboard equals only 16 outgoing ways.ArTu PB Custom Panelboard General informationThe new ArTu PB panelboard gives you the flexibility to design your own custom panelboard.There are three sizes for the fixed panelboard, 6, 12 and 18 outgoing ways, and each one can be equipped with an incoming breaker from 250 A to 800 A, three or four pole.Each panelboard has a fixed dimension of copper depending on the quantity of outgoing ways you require.All you have to do is select the plug-in bases and fill up the copper bar to suit the breakers you need.Any left over copper can be shrouded and MCB blanking platescan be used to fill out the inner door.6ABB SACEABB SACE7ArTu PB Custom Pan Assembly General informationAlso the pan assembly version allows you to design your own customized switchboard. As for the panelboard, it is available in three sizes with 6, 12 and 18 outgoing ways, each of which can be equipped with an incoming breaker from 250 A to 800 A, three or four pole.As standard the pan assembly is supplied as a three or four pole.Each pan assembly has a fixed dimension of copper depending on the quantity of outgoing ways you require. All you have to do is select the plug-in bases and fill up the copper bar to suit the breakers you need. Any left over copper can be shrouded andMCB blanking plates can be used to fill out the inner door.8ABB SACEArTu PB Custom Pan AssemblySelectionCustom Pan AssemblyOrder code* T3 4 pole beakers equals only 16 outgoing ways.ABB SACE9ArTu PB PanelboardIncoming selection kitDirect connection kitSTEP 2Select the incoming connection kitrequired from the table below.Order codeIncomer options(Connection kits must be ordered with each incoming breaker)Order codeArTu PB PanelboardMCCB Outgoing breaker selectionSTEP 3Select the outgoing devices requiredfrom the table below.T1B Single pole MCCB(Thermomagnetic release)Order codeT1B Three pole MCCB(Thermomagnetic release)Order codeT1C Three pole MCCB(Thermomagnetic release)Order codeArTu PB PanelboardMCCB Outgoing breaker selectionT1N Three pole MCCB(Thermomagnetic release)Order codeT3N Three pole MCCB(Thermomagnetic release)Order codeT3S Three pole MCCB(Thermomagnetic Release)Order codeFront connection terminal sets are required for all T3 outgoing devices.ArTu PB PanelboardAccessoriesShunt opening release - SOR(cabled version)Undervoltage release - UVR(cabled version)Auxiliary contacts - AUX(cabled version)High terminal cover HTCOrder codeFront terminal for copper cables - FC CUMCCBArTu PB PanelboardAccessoriesGlazed door for panelboardPlinthTop/Bottom extension modulesSide extension modules for panelboardOrder CodeMetering extension modulesCustom PanelboardArTu PB PanelboardAccessoriesPlug In deviceAccessoriesCustom Panelboard and Pan AssemblyIPIP122nd number defined by the CEI 70-1 – IEC 529 Standards1S T C 802095F 0001ArTu PBIn-depth technical informationArTu PBIn-depth technical informationFigure defined by the CEI EN 50102 StandardArTu PB PanelboardIn-depth technical informationCompliance with CEI EN 60439-1 StandardThe ArTu PB Panelbord have undergone the type tests foreseen by the CEI EN 60439-1 Standards. The results of these tests guarantee the performances of the ArTu switchboards and, by using the metalwork structures, ABB SACE air, modular and moulded-case circuit-breakers, mean that the end switchboard constructor does not have to carry out any further type tests by following the selection criteria and the assembly instructions for the various components. These results, which are indicated below, can be referred to for making out the declaration of conformity of the switchboard.Over-temperature (Ref. par. 8.2.1 of the Standard)The table on page 7/5 and following pages shows the thermal dissipation values referred to all the dimensions of ArTu switchboards and to the type of installation, deriving from the type tests carried out. The dissipated power data (in Watt) is according to the admissible over-temperature inside the switchboard (appropriately taking into account the simultaneity factor).ArTu PBRated service voltage:up to 690V ACRated insulation voltage:up to 1000V ACRated impulse withstand voltage:8kVArTu PB up to 400A ArTu PB up to 800AShort-circuit withstand current:phase-phase35kA (1s)50kA (1s)phase-neutral21kA (1s)30kA (1s)Rated max. peak short-circuit current:52,5kA73,5kAArTu PB up to 400A ArTu PB up to 800A(Rif. par. 8.2.4.1)Following the assembly indications of the metal components, the effective electrical continuitybetween the exposed conductive parts is verified, with negligible resistance values.(Rif par. 8.2.4.2)Protection circuit short-circuit withstand current: phase-earthing busbar21kA (1s)30kA (1s)The insulation distances are guaranteed by following the ABB SACE metalwork structure and circuit-breaker assembly and mounting instructions. Mechanical operation is verified by following the assembly and mounting instructions of the ABB SACE metalwork structures and circuit-breakers.ArTu PBWith door IP 43ArTu PB with the following rated characteristics:Rated service voltage up to 690 V Rated insulation voltage up to 1000V Rated current / I CW ArTu PB up to 400A / 35kA flat busbar ArTu PB up to 800A / 50kA profiled busbar Degree of protectionArTu PBIP 43 (with door)ArTu PB PanelboardIn-depth technical informationMaterialArTu PB structure 12/10mm thick pickled steel sheet Panels 12/15/10mm thick steel sheetDoors15/10mm hot galvanised steel sheet. 4mm thick glass tempered from insidePaintingStructureColour Grey orange-peel RAL 7035Base strip colour Grey RAL 7012Standard cycleSheet washingPhosphating with iron salt base Drying in tunnel at 100°CExternal and internal painting with electrostatic application of thermosetting powder enamel with epoxy polyester binders. Grey orange-peel RAL 7035 colour, total thickness: 60/70 micron.Polymerisation in oven at 180°C.Paint characteristicsBinder:epoxy polyester Specific gravity: 1.61 g/cm 3Theoretical coverage:10.4 m 2/kg with average film thickness 60 micron Melting point:85-95°C (Kofler bench method)Granulometry:standard distribution between 5 and 100 micron with average size of theparticles between 30 and 40 micron. Hardening: 12 min. at 190°C (temperature of object)Hardness:1H - 2H DIN 53152 bending elasticity:unaltered on 1/4” spindle DIN 53151 reticular adherence:GT O (100%)Erichem elasticity:SEN DIN 53156: > 6mm Gardner resistance to impact:25 Kg. x cm.Tests carried out on degreased and phosphated sheets with film thickness of 60/70 micron.The painting has passed the resistance tests to saline fog (193 hours).Ambient characteristicsType of installation indoors Installation conditions Wall / Floor Service climate (t ° /% r.h.)constant 23°C/83% - 40°C/93%variable 23°C/98% - 40°C/98%Ambient temperature limitsoperating -5°C +40°C storage-25°C +55°CThe above is valid if the switchboard is designed and constructed:•selecting the materials according to the performances indicated in the ABB catalogues;•sizing the conductors according to the prescriptions of the EN 60439-1 and CEI 64-8 Standards;•carrying out the individual tests foreseen under the EN 60439-1 Standard successfully.when correctly selected and assembled, as per the indications given in this catalogue and in the instruction manual, they allow construction of switchboards complying with the EN 60439-1 Standard, on the basis of what is foreseen by the Low Voltage Directive of the European Community (Directive 73/23/EEC, Law 791/1977).ArTu PB Panelboard Overall DimensionsArTu PB PanelboardOverall Dimensions21ABB SACEArTu PB PanelboardOverall Dimensions22ABB SACE23ABB SACE In the case of structures W=900mm (with internal or external cable container) containing busbar systems, check the centre of gravity before handling.Structure(mm)(mm)(mm)(mm)ArTu PBWidth 600mm4759697296For greater safety during transport using a fork-lift truck,it is advisable to anchor the switchboard to the truck:To handle using a crane or overhead travelling crane, check the following conditions before lifting the switchboard:excellent state of the ropes or chains;•the angle between the lifting ropes and the switchboard roof must be ≥ 45°;•the maximum number of columns transported is 3;•ArTu PB maximum weight lifted as per DIN 580 (M8).To respect the conditions described above, a lifting beam with appropriate characteristics can be used when there are several columns side by side.24ABB SACEArTu PB PanelboardList of codes640T1PB3400A 6 way 3 pole T1 outgoing 160A 1050x690x20474,95640T3PB3400A 6 way 3 pole T3 outgoing 250A 1250x690x20486,35680T3PB3800A 6 way 3 pole T3 outgoing 250A 1250x690x20487,25640T1PB4400A 6 way 4 pole T1 outgoing 160A 1250x690x20485,65640T3PB4400A 6 way 4 pole T3 outgoing 250A 1450x690x24099,65680T3PB4800A 6 way 4 pole T3 outgoing 250A 1450x690x240101,05124T1PB3400A 12 way 3 pole T1 outgoing 160A 1450x690x240100,15124T3PB3400A 12 way 3 pole T3 outgoing 250A 1650x690x240109,55128T1PB3800A 12 way 3 pole T1 outgoing 160A 1450x690x240101,35128T3PB3800A 12 way 3 pole T3 outgoing 250A 1650x690x240111,15124T1PB4400A 12 way 4 pole T1 outgoing 160A 1650x690x240112,05124T3PB4400A 12 way 4 pole T3 outgoing 250A 1850x690x240125,95128T1PB4800A 12 way 4 pole T1 outgoing 160A 1650x690x240114,15128T3PB4800A 12 way 4 pole T3 outgoing 250A 1850x690x240128,75184T1PB3400A 18 way 3 pole T1 outgoing 160A 1850x690x240127,65188T1PB3800A 18 way 3 pole T1 outgoing 160A 1850x690x240130,05188T3PB3800A 18 way 3 pole T3 outgoing 250A 2050x690x240138,65184T1PB4400A 18 way 4 pole T1 outgoing 160A 2050x690x240139,95188T1PB4800A 18 way 4 pole T1 outgoing 160A 2050x690x240143,05188T3PB4800A 16 way 4 pole T3 outgoing 250A 2050x690x240145,15CU680PB3 6 Way 3 pole (800A Busbar) 1250mm High 1250x690x20485,77CU128PB312 Way 3 pole (800A Busbar) 1650mm High 1650x690x240105,97CU188PB318 Way 3 pole (800A Busbar) 2050mm High 2050x690x240128,77CU680PB4 6 Way 4 pole (800A Busbar) 1450mm High 1450x690x24095,37CU128PB412 Way 4 pole (800A Busbar) 1850mm High 1850x690x240117,37CU188PB418 Way 4 pole (800A Busbar) 2050mm High 2050x690x240131,37CU680PA3 6 Way 3 pole (800A Busbar) 1177mm High 1177x544x10518,09CU128PA312 Way 3 pole (800A Busbar) 1577mm High 1577x544x10524,09CU188PA318 Way 3 pole (800A Busbar) 1977mm High 1977x544x10527,99CU680PA4 6 Way 4 pole (800A Busbar) 1377mm High 1377x544x10519,09CU128PA412 Way 4 pole (800A Busbar) 1777mm High 1777x544x10525,89CU188PA418 Way 4 pole (800A Busbar) 1977mm High 1977x544x10530,59400DC3/4P 400A Direct connection kit 3 and 4 pole 1,010800DC3P 800A Direct connection kit 3 pole 2,210800DC4P 800A Direct connection kit 4 pole 2,610P6X6DC Direct connection inner door 4,810250T33P 250A T3 3 pole MCCB connection kit 3,010250T34P 250A T3 4 pole MCCB connection kit 3,410P6X6T3T3 inner door7,5310400S53P 400A S5 3 pole MCCB connection kit 3,610400S54P 400A S5 4 pole MCCB connection kit 4,210630S53P 630A S5 3 pole MCCB connection kit 3,710630S54P 630A S5 4 pole MCCB connection kit 4,410P6X6S5S5 inner door7,5310800S63P 800A S6 3 pole MCCB connection kit 3,110800S64P 800A S6 4 pole MCCB connection kit 3,510P6X6S6S6 inner door 7,5310PV1000Glazed Door 1000mm 1000h x 690w 10,314PV1200Glazed Door 1200mm 1200h x 690w 12,314PV1400Glazed Door 1400mm 1400h x 690w 14,414PV1600Glazed Door 1600mm 1600h x 690w 16,314PV1800Glazed Door 1800mm 1800h x 690w 18,314PV2000Glazed Door 2000mm2000h x 690w20,314ZL1000Four Corner Feet 100mm High For Main Structure 2,514ZL1001Finishing Profile For Above Plinth1,114Part DescriptionDimensions Weights Page Number (Kg)Part DescriptionDimensionsWeights Page Number (Kg)ZL3000Two Feet 100mm High For Side Extension Box 1,514ZL2001Finishing Profile For Side Extension Box 0,714200EXMOD 200mm High top & bottom extension box 200h x 690w 12,514RC1000385mm structure extension box 385h x 690w 24,014RC2000385mm cable container extension box 385h x 390w 18,014MI1000Side Extension Box Uprights 1000mm 1000mm 2,814VC1000Side Extension Box Cable Container 1000mm 1000mm 9,814PC1002Side Extension Box Front Door 1000mm 1000mm 5,714MI1200Side Extension Box Uprights 1250mm 1250mm 3,414VC1200Side Extension Box Cable Container 1250mm 1250mm 11,714PC1202Side Extension Box Front Door 1250mm 1250mm 7,214MI1400Side Extension Box Uprights 1450mm 1450mm 4,014VC1400Side Extension Box Cable Container 1450mm 1450mm 13,714PC1402Side Extension Box Front Door 1450mm 1450mm 8,414MI1600Side Extension Box Uprights 1650mm 1650mm 4,514VC1600Side Extension Box Cable Container 1650mm 1650mm 15,014PC1602Side Extension Box Front Door 1650mm 1650mm 9,514MI1800Side Extension Box Uprights 1850mm 1850mm 5,114VC1800Side Extension Box Cable Container 1850mm 1850mm 16,214PC1802Side Extension Box Front Door 1850mm 1850mm 10,614MI2000Side Extension Box Uprights 2050mm 2050mm 5,714VC2000Side Extension Box Cable Cotainer 2050mm 2050mm 18,014PC2002Side Extension Box Front Door 2050mm 2050mm11,814PLT11L1/L3P T1 Single Pole L1 & L3 plug in base0,315PLT11L2P T1 Single Pole L2 plug in base 0,315PLT13P T1 Three Pole plug in base 0,915PLT14P T1 Four Pole plug in base 0,415PLT23P T2 Three Pole plug in base 1,015PLT24P T2 Four Pole plug in base 0,415PLT33P T3 Three Pole plug in base 1,115PLT34P T3 Four Pole plug in base 0,515PLRCD Dummy Base For RCD0,915SH630Busbar Shroud 630mm Long 3 pcs 630mm Long 0,315MODT1T1 Busbar Shroud 10pcs 0,115MODT2T2 Busbar Shroud 10pcs 0,115MODT3T3 Busbar Shroud 10pcs 0,115SPARE1Spares Kit0,815200EXMET200mm High metering box200h x 690w11,81S T C 005001B 0901 06/’03P r i n t e d i n I t a l y 2.000/O c é F a c i l i t y S e r v i c e s S P A /C A LABB SACE S.p.A.Automation and Distribution Boards23846 Garbagnate Monastero (LC) - Italy Via Italia, 58Tel.: ++39 031.3570.1 - Telefax: ++39 031.3570.228To take into account the evolution of Standards and materials, the characteristics and overall dimensionsindicated in this catalogue can only be considered binding after confirmation from ABB SACE.Certificate N °1612/98/S Certificate N °EMS-051Certificate N °OHS-015。
ABB空开选型
![ABB空开选型](https://img.taocdn.com/s3/m/1ca8f8c9b04e852458fb770bf78a6529647d35c9.png)
ABB空开选型
选型: S 5 N 400 PR212-LSI R400 3P/4P F 或W
塑壳壳架号分断能力壳架电流脱扣器保护类型整定电流值极数固定或抽出式
1. ABB 可提供具有通信功能的断路器以及其它更多功能的断路器,详情见样本。
2. S / E 型断路器的电子脱扣器 PR211/2 和 PR111 的脱扣值 L / S / I / G 多档可调;如:选定整定电流值后仍有 40% -- 100% 的电流调整范围;例如选型为:
E2N1600 PR111/P - LI R 800 4P W 则此断路器可在 320A -- 800A 间调节;
E 3 N 2500 PR111-LSI R1600 3P/4P
F 或W
框架框架号分断能力框架电流脱扣器保护类型整定电流值极数固定或抽出式ABB 塑壳断路器、空气断路器快速选型表
注:ABB可提供分断能力达200KA及壳架电流达3200A的塑壳断路器;。
abb低压电器选用手册
![abb低压电器选用手册](https://img.taocdn.com/s3/m/658e50e2ba0d4a7302763a73.png)
低压产品目 录页1.断路器空气断路器 - Emax 空气断路器 - New Emax 空气断路器 - Megamax 塑壳断路器 - Isomax 漏电保护组件/漏电保护继电器 塑壳断路器 - Tmax 双电源自动切换装置 - DPT 配电智能化元件 - IPD 2.工控产品软起动器接触器建筑用接触器 - ESB (导轨安装)手动电机起动器 - MS 系列短路保护电器和接触器及热继电器的配合电机控制/保护器件指示装置接线端子3.开关及熔断器组开关熔断器组 - OS/OESA (32…800A)负荷开关 - OT/OETL (16…3150A)熔丝开关 - Easyline/Fastline 4.终端配电保护建筑电器元件电涌保护器 - OVR 5.箱体终端配电箱 - ACM/ACP/ACF 系列三相配电箱 - SDB 系列动力配电箱 - MDS 系列6.电网质量产品无功补偿控制器件有源谐波滤波器7.断路器保护配合表断路器保护配合表因产品技术不断改进,所有数据应以本公司最新确认为准。
ABB 公司对本手册的接受或使用无任何商业承诺或保证,由使用者根据具体应用考虑本手册的适应性。
0/1ABB 低压电器元件选用手册1234567...................................................................................... 1/1-3.............................................................................. 1/4-7................................................................................ 1/8-9................................................................................ 1/10-15........................................................................ 1/16.................................................................................. 1/17-20............................................................................ 1/21............................................................................... 1/22-23..................................................................................................... 2/1-7........................................................................................................... 2/8........................................................................ 2/9......................................................................... 2/10-12.......................................................... 2/13................................................................................... 2/14-22................................................................................................. 2/23-24................................................................................................. 2/25-26............................................................. 3/1................................................................ 3/2-3........................................................................ 3/4-5............................................................................................. 4/1-13........................................................................................ 4/14..................................................................... 5/1................................................................................. 5/2-3................................................................................. 5/4-5........................................................................................ 6/1-4.............................................................................................. 6/5........................................................................................ 7/1-5。
塑壳T系列MCCB-Tmax(abb断路器选型和技术参数)
![塑壳T系列MCCB-Tmax(abb断路器选型和技术参数)](https://img.taocdn.com/s3/m/65bc27cb8bd63186bcebbc82.png)
2011年参考价目表 -Tmax 塑壳断路器(T型)Tmax 塑壳断路器(T型)速选表 - 固定式单价包括:1. 固定式塑 3. 接线形式2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------2. 脱扣单元 - FF (前接 - 热磁脱 - FFC (前 --- 电子脱 4.附件(只针 - - 弹簧储能电 -------。
ABB电子版选型手册-5月11日
![ABB电子版选型手册-5月11日](https://img.taocdn.com/s3/m/20fc7f6202768e9950e73807.png)
0.4-1.0倍,步距 0.04倍 0.4-1.0倍,步距 0.02倍0.4-1.0倍,步距 0.02倍Tmax型号说明,四段保护,额定电流800A,4极,单磁保护,额定电流250A,3极Tmax 型号说明塑壳断路器漏电组件及漏电保护继电器1.漏电组件T1-160/3P或4P+RC221/RC222T2-160/3P或4P+RC221/RC222T3-250/3P或4P+RC221/RC222T4-320/4P或T5-630/4P+RC222注: 1.RC221漏电动作电流:0.03--0.1--0.3--0.5--1--3A 可调。
2.RC222漏电动作电流:0.03--0.05--0.1--0.3--0.5--1--3--5--10 A 可调。
3.RC222延迟时间: 0--0.1--0.2--0.3--0.5--1--2--3S可调。
4.RC222可提供预报警信号触头和报警信号触头。
2.漏电保护继塑壳型号 +RCQ注: 1.RCQ 漏电动作电流:0.03--0.05--0.1--0.3--0.5--1--3--10--30 A 可调。
2.延迟时间: 0--0.1--0.2--0.3--0.5--0.7--1--2--3--5S可调。
3.可提供报警接点。
协议报警ModbusRTUstandard测量功能相电流,中性线电流,接地电流维护信号功能L 功能的LED预报警与报警L 功能报警接点输出数据获取开关况态: 开-合模式: 本机, 远程操作机构保护参数设置IL, S, I, G功能报警脱扣控制失败报警操作总次数脱扣和脱扣测试总次数人工操作总次数各种保护功能脱扣的次数最后一次脱扣的相关数据开关分合(通过马达操作)报警重置开关再扣 (通过马达操作)设定保护装置的曲线和脱扣值。
ABB断路器参数调试讲义
![ABB断路器参数调试讲义](https://img.taocdn.com/s3/m/203d5bbbf021dd36a32d7375a417866fb84ac04f.png)
ABB 断路器参数(cānshù)调试讲义电控柜的断路器进行设置,在ABB 塑壳断路器(正面)下方有两个旋钮(见下图),通过调节(ti áoji é)旋钮的位置可以设置断路器的过流、过载保护值,具体设置方法如下:一、ABB 塑壳断路器过流、过载(gu òz ài)旋钮设置说明:1、过流调节旋钮,设置电控箱整个负载(f ùz ài)的过流保护值,调节范围从2000A —4000A ,从MIN —MED —MAX 共有9个档位,档位对应(du ìy ìng)值如下:过流调过载调MIN(1)档—2000A; (2)档—2250A; (3)档—2500A; (4)档—2750A;MED(5)档—3000A; (6)档—3250A; (7)档—3500A; (8)档—3750A;MAX(9)档—4000A;2、过载(guòzài)调节旋钮,设置电控箱整个负载的过载保护值,调节范围从280A—400A,从MIN—MED—MAX共有9个档位,档位对应(duìyìng)值如下:MIN(1)档—280A; (2)档—295A; (3)档—310A; (4)档—325A;MED(5)档—340A; (6)档—355A; (7)档—370A; (8)档—385A;MAX(9)档—400A;二、ABB断路器机型设置(shèzhì)说明三ABB断路器低压(dīyā)断路器的参数详解3.1、空气断路器的框架电流(diànliú)Iu、额定电流Ie、额定电流整定值Ir的含义是什么?•框架(kuànɡ jià)电流Iu:又称为额定不间断电流。
指在规定条件下,电器在长期工作制下,各部件的温升不超过规定极限值时所承受的电流值。
•额定工作(gōngzuò)电流Ie:指在规定条件下,能保证电器正常工作的电流值。
ABB电气元件选用手册
![ABB电气元件选用手册](https://img.taocdn.com/s3/m/7cae29a34693daef5ef73d50.png)
目 录页1.断路器空气断路器 - New Emax 空气断路器 - Megamax 塑壳断路器 - Isomax 漏电保护组件/漏电保护继电器 塑壳断路器 - Tmax 双电源自动切换装置 - DPT 配电智能化元件 - IPD 2.工控产品软起动器接触器建筑用接触器 - ESB (导轨安装)手动电机起动器 - MS 系列短路保护电器和接触器及热继电器的配合电机控制/保护器件指示装置接线端子3.开关及熔断器组开关熔断器组 - PowerLine 负荷开关 - SwitchLine 熔断器开关 - EasyLine/FastLine 4.终端配电保护产品建筑电器元件电涌保护器 - OVR 5.箱体终端配电箱 - ACM/ACP/ACF 系列三相配电箱 - SDB 系列动力配电箱 - MDS 系列6.电网质量产品无功补偿控制器件有源谐波滤波器7.断路器保护配合表断路器保护配合表因产品技术不断改进,所有数据应以本公司最新确认为准。
ABB 公司对本手册的接受或使用无任何商业承诺或保证,由使用者根据具体应用考虑本手册的适应性。
0/1ABB 低压电器元件选用手册1234567.............................................................................. 1/1-4................................................................................ 1/5-6................................................................................ 1/7-12........................................................................ 1/13.................................................................................. 1/14-17............................................................................ 1/18............................................................................... 1/19-20..................................................................................................... 2/1-7........................................................................................................... 2/8........................................................................ 2/9......................................................................... 2/10-12.......................................................... 2/13................................................................................... 2/14-22................................................................................................. 2/23-24................................................................................................. 2/25-26............................................................................... 3/1.................................................................................. 3/2-3................................................................... 3/4-5............................................................................................... 4/1-8........................................................................................... 4/9..................................................................... 5/1................................................................................. 5/2-3................................................................................. 5/4-5........................................................................................ 6/1-4.............................................................................................. 6/5........................................................................................ 7/1-53/1开关熔断器组 - OS/OESA (32…800A )开关熔断器组 - P o w e r L i n e 3说 明:1. 开关熔断器组不包括熔断器,熔断器需另行订购2. 熔断器应符合 IEC 有关标准。
ABB选型手册
![ABB选型手册](https://img.taocdn.com/s3/m/65aad2cfda38376baf1faec8.png)
4 S264-C0.5 S264-C01 S264-C04 S264-C06 S264-C10 S264-C16 S264-C20 S264-C25 S264-C32 S264-C40 S264-C50 S264-C63 S284-C80 S284-C100
分断 能力
6KA
6KA
4 S264-D0.5 S264-D01 S264-D02 S264-D03 S264-D04 S264-D06 S264-D10 S264-D16 S264-D20 S264-D25 S264-D32 S264-D40 S264-D50 S264-D63
ABB微断选型 分断
6KA
电流(A) 6 10 16 20 25 32 40 50 63 GS261-D6 GS261-D10 GS261-D16 GS261-D20 GS261-D25 GS261-D32 GS261-D40 GS261-D50 GS261-D63
2P(电子式) GS262-D6 GS262-D10 GS262-D16 GS262-D20 GS262-D25 GS262-D32 GS262-D40 GS262-D50 GS262-D63
分断
6KA
ABB--MCB
3P(电子式) GS263-D6 GS263-D10 GS263-D16 GS263-D20 GS263-D25 GS263-D32 GS263-D40 GS263-D50 GS263-D63
4P(电子式) GS264-D6 GS264-D10 GS264-D16 GS264-D20 GS264-D25 GS264-D32 GS264-D40 GS264-D50 GS264-D63
4 E234-32 E234-45 E274-63 E274-80 E274-100 E274-125
ABB 塑壳断路器S系列
![ABB 塑壳断路器S系列](https://img.taocdn.com/s3/m/cc131d8b6529647d2728521f.png)
t1 = 3...18s (在6*I1时) 或 A...D 4条曲线。 t2 = 0.05...0.5s 或 A...D 4条曲线(有I2 t = C可选)
t4 = 0.1...0.8s 或 A...D 4条曲线。(有I2 t = C可选)
电机保护整定范围: (PR212MP)(即 LRIU)
过载长延时 转子堵转 短路瞬动 断相或相不平衡
S3X: F / EF / R S6X: F / EF / R
插入式和抽出式断路器的接线方式参见样本 黑色字母接线方式不推荐
安装方式可选: F: 固定式 P: 插入式(S6不适用) W: 抽出式(S2不适用)
极数可选:
3P 或 4P
脱扣器保护段数可选:
I:
短路瞬动
LI:
长延迟+瞬动
LSI:
长延迟+短延迟+瞬动
黑色字母不推荐选用
带 * 标记为即将推出新品
框架号码可选: 1 I = 125 3 I = 160, 250 6 I = 630, 800 *
2 I = 160 5 I = 400, 630
1/7
ABB 低压电器元件选用手册
塑壳断路器 - Isomax
塑壳断路器 - Isomax
微处理器脱扣器的常用规格
排列说明: V : 垂直安装
H : 水平安装
热敏电磁脱扣器额定电流 Ir 可选: S2-160: 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160 S3-250: 32, 40, 50, 63, 80, 100, 125, 160, 200, 250 S3及以下磁脱扣固定为10倍, 非标可有5倍或单磁。
t6 = 4S
当由上级计算机通过通讯单元 PR212/D 进行整定时可获得比手动整定更精细的间隔。
abb断路器 参数
![abb断路器 参数](https://img.taocdn.com/s3/m/d53cf8aedbef5ef7ba0d4a7302768e9950e76e5d.png)
abb断路器参数
(原创版)
目录
1.ABB 断路器概述
2.ABB 断路器型号大全
3.如何查看 ABB 断路器型号参数
4.ABB 断路器的应用范围
5.结束语
正文
一、ABB 断路器概述
ABB 断路器是一种用于保护电路和设备的电气开关,具有防止故障发生和提供最佳解决方案的功能。
它提供了最优的电气安装保护,广泛应用于各种领域。
从微型断路器到高分断能力的塑壳、空气断路器,ABB 已经解决了在其范围内的所有技术问题。
二、ABB 断路器型号大全
1.框架:emax2
2.塑壳:xtmax,formula,tmax
3.微断:sh200,s200
三、如何查看 ABB 断路器型号参数
1.额定电压:指断路器正常工作时,系统的额定线电压。
这是断路器的标称电压,应能保持在这一电压的电力系统中使用,最高工作电压可超过额定电压 15%。
2.额定电流:指断路器在规定使用和性能条件下可以长期通过的最大电流。
当额定电流长期通过高压断路器时,其发热温度不应超过国家标准
中规定的数值。
3.额定短路开断电流:指断路器在规定的时间内能够切断的最大短路电流。
四、ABB 断路器的应用范围
ABB 断路器广泛应用于工业、能源、基础设施、交通、建筑等领域,为各种电路和设备提供可靠的保护。
五、结束语
作为世界 500 强企业,ABB 公司一直致力于为客户提供高质量的电气产品和解决方案。
从微型断路器到高压柜、低压柜、变压器及其他系列产品,ABB 都能提供优质的服务。
ABB断路器介绍
![ABB断路器介绍](https://img.taocdn.com/s3/m/7a9d5ce77d1cfad6195f312b3169a4517723e5d6.png)
ABB断路器介绍ABB断路器介绍⼀、⾼压断路器1.真空断路器VD4系列1.1固定式VD4真空断路器VD4 12.06.251.2⼿车式VD4真空断路器VD4/Z 12.06.25参数说明:12—额定电压等级12KV06—额定电流630A 额定电流范围630~2500A25—额定开断能⼒25KA 31.5KA 40KAVD4 断路器使⽤在配电系统中,可适⽤于控制和保护电缆、架空线、变压器、马达、发电机和电容器组。
2.六氟化硫断路器HD4 12~40.5 630~3600 16~50额定电压等级12~40.5KV额定电流630~3600A额定开断能⼒16~50KA3.真空断路器和六氟化硫断路器特点1.真空断路器较相应六氟化硫断路器价格便宜.2.真空断路器较相应六氟化硫断路器机械寿命和电⽓寿命长.3.真空断路器投切时,容易产⽣重燃,⽽六氟化硫可以做的⽐较好4.12KV系统中⼤都采⽤真空断路器,⽽40.5KV以上⼤都采⽤六氟化硫断路器.⼆、低压断路器1、框架断路器Emax系列E系列型号案例:E1B PR111/P-LI R 1250 3P W HRE1—框架号码,框架电流E1 1250A、E2 2500A、E3 3200A、E4 4000A、E6 6300A B—额定分断能⼒40~130KA PR111/P-LI—脱扣器保护种类过载长延时脱扣保护(L)短路短延时脱扣保护(S)"短路瞬时脱扣保护(I)接地故障脱扣保护(G)1250—脱扣器额定电流250~6300A3P—3极W—抽出式HR—⽔平后接线⽅式E系列主要特征Emax 系列的断路器提供 PR121/P、PR122/P 及 PR123/P 三种电⼦脱扣器,适⽤于交流系统。
基本型 PR121/P 提供整套的标准保护功能和⼀个完善友好的⽤户界⾯。
依靠 LED 显⽰器,它能区别故障脱扣的种类。
PR122/P 和 PR123/P 采⽤了新的模块化结构概念,根据设计和⽤户的要求,可实现⼀套集完整的保护、准确的测量、信号指⽰或者对话功能为⼀体的断路器。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
主要特性
FORMULA 塑壳断路器使用具有特殊防伪技术的全息图防伪标签,以确保该断路器是 ABB 产品。
ABB 质量管理体系符合标准如下:
• ISO 9001 标准 • EN ISO 9001(等效)欧盟标准 • UNI EN ISO 9001(等效)意大利标准 • IRIS 国际铁路行业标准
ABB 环境管理体系,社会责任与道德规范标准如下:
特性曲线和技术参数
4 曲线例子 ............................................................................................ 4/1
温度性能 ............................................................................................ 4/2 脱扣曲线 ............................................................................................ 4/4 允通曲线 ............................................................................................ 4/6 限流曲线 ............................................................................................ 4/9 功率损耗 ............................................................................................ 4/12 后备保护 ............................................................................................ 4/13
– SACE A1 和 A2:电流至 250A(A1 125A 除外)
– SACE A3
:300 - 400A 50°C 的特殊规格
所有 FORMULA 断路器的详细温度性能,查阅特性曲线和技术参数。
B
A B
防护等级
1SDC210613F0001
• 不同的 IP 防护等级
断路器
断路器
断路器带旋转 断路器带高端子 断路器带低端子 断路器带手柄操作
塑壳断路器 FORMULA
技术资料
断路器类产品 塑壳断路器
FORMULA
目录
页
主要特性
1 产品概述 ............................................................................................ 1/1
管理体系和符合标准 .......................................................................... 1/2 断路器铭牌 ........................................................................................ 1/3
带前接线端子 不带前接线端子1) 手柄 RHE RHD 盖板 HTC
盖板 LTC 机构前面板 FLD
A IP 40
IP 20
IP 40
IP 40
IP 40
IP 40
B IP 20
IP 20
IP 20
IP 40
IP 30
IP 20
1) 安装了电气附件
• 所有 FORMULA 断路器都带有测试按钮,可用于脱扣测试,测试操作只在闭合位置可实现。
附件
3 附件概览 ............................................................................................ 3/1
机械附件 ............................................................................................ 3/2 电气附件 ............................................................................................ 3/5
1SDC210612F0001
测试按钮
FORMULA
1/1
塑壳断路器 - FORMULA
管理体系和符合标准
符合标准
1
FORMULA 系列塑壳断路器及附件均符合下列标准制造: • 标准:
– IEC 60947-2,GB14048.2-2008
• 指令:
全息防伪标签
– EC 指令:“低压指令” (LVD) no. 2006 / 95 / CE – EC 指令:“电磁兼容性指令”(EMC)no. 89 / 336 EEC
电气线路图
5 阅读信息与图形符号 .......................................................................... 5/1
断路器接线图 ..................................................................................... 5/2 电气附件 ............................................................................................ 5/3
三个框架皆为固定式,标配前接线端子。
出厂前预先整定的热磁脱扣单元规格简明易选,现场安装,避免 设定错误,方便设备厂商工人使用,以及客户将来的备件替换。
体积轻巧、订购方便、安装简单、设置快速,带给用户前所未有 的简洁特性。
FORMULA 简单准确的选择
FORMULA 集成了 ABB 的高质量、高可靠性和简洁的所有特性, 是一款真正的简单实用型塑壳断路器。 尺寸减小了,但仍确保卓越的性能和可靠性,并具有比市场上 所有同类断路器产品都高的性能尺寸比,可为用户提供更多空 间来进行电缆布线,减小开关柜尺寸。 紧凑尺寸具有极大的优越性,对 OEM 厂商、板厂和安装工人特 别适用。 FORMULA A1 和 A2 是唯一能在 60mm 深度上实现电流250A 的 高性能断路器。
断路器铭牌
正面标签 7
1 9
10 In=100A
1SDC210614F0001
484 98
4000m A1 - A2 - A3
429 95
5000m A1 - A2 - A3
374 90
可靠操作
1SDC210612F0001
• FORMULA 系列断路器可在环境温度 -25°C 至 +70°C 下正常工作,储存的环境温度为 -40°C 至 +70°C,下列 FORMULA 断路器在正常条件下 50°C 时可承受 100% In 不脱扣。
• 符合 ISO 14001 标准 • OHSAS 18001 工作场所的健康和安全管理体系 • SA8000 管理标准规范商业道德和工作环境
ABB 一直致力于环境保护,体现如下:
• 优化选材,加工工艺和包装方式减轻对环境的影响 • 使用可回收利用材料 • 符合 ROSH 指令
1/2
FORMULA
塑壳断路器 - FORMULA
双重绝缘 安装位置
1SDC210610F0001
1SDC210611F0001
塑壳断路器 - FORMULA
产品概述
FORMULA 系列塑壳断路器都具有下列特性:
• 双重绝缘 • 可靠操作
1
• 隔离功能
• 电磁兼容性
• 电源可上进线或下进线
主要特性
• 多方位安装,可以水平、垂直、侧躺安装断路器而对性能没有任何影响
外形尺寸
6 FORMULA A1 ................................................................................... 6/1
FORMULA A2 ................................................................................... 6/6 FORMULA A3 ................................................................................... 6/10 FORMULA Link(250A、400A、630A、800A) ............................... 6/15 安装间距 ............................................................................................ 6/19
订货资料
7 FORMULA A1 ................................................................................... 7/1
FORMULA A2 ................................................................................... 7/2 FORMULA A3 ................................................................................... 7/2 机械附件............................................................................................. 7/3 电气附件............................................................................................. 7/5 附件(FORMULA Link)..................................................................... 7/6