WS2813规格书
DiGidot C4 V.20190227说明书
•Up to 8 universes (4096 channels) •Supports more than 50 protocols •Art-Net + DMX in & out•Art-Net/DMX recording & playback •Analog + digital triggers •Compact size•Wide voltage range (5-24 Vdc) •Easy to connect•Web interface & free App •Reliable & easy to useDiGidot C4 ExtendedIntroductionThe DiGidot C4 Extended is a multi functional LED pixel controller that converts Art-Net and DMX to SPI protocols. The output capacity goes up to 8 universes, which is 4096 channels. (depending on thelicense) The internal DHCP server, Wi-Fi and free DiGidot App grand easy access of the built in webinterface. A built in network switch allows multiple DiGidot C4 controllers to be daisy chained to create an extensive control network. The DiGidot C4 Extended o ff ers Art-Net & DMX recording, playback and triggering. Extensive triggering options such as analog and digital triggers as well as the built in calendar o ff er great flexibility for system integration. Countless extra features such as DMX in and out, Art-Net IP Address filter, Art-Net routing, HTP input signal merger, Art-Net & DMX Monitor, in-/output channel repeater, Gamma correction, adjustable fall back color, output limiters, make this product to the most powerful LED pixel controller on the market.Product imagesDATA SHEETArt. No. 20201- DiGidot C4 Extended 1 Art. No. 20202 - DiGidot C4 Extended 2 Art. No. 20203 - DiGidot C4 Extended 4Art. No. 20204 - DiGidot C4 Extended 8Pixel ControllerWiring schemes (Data) SPIDMX inDMX outSPIFor more wiring schemes, and technical information, please read the DiGidot C4 user manual.Wiring schemes (Power)DC +DC --D1D2D3D4V+PSUAC/N AC/LGND V -C4DOIMPORTANT : All Grounds, from the DiGidot C4 and all power supplies must be connected. The Ground output wires of each Data pair from the DiGidot C4 output must be equal in length as the Data wires.SpecificationsInput voltage5-24 VdcMax. Power consumption5WHousing material Self extinguishing Acrylonitril-Butadieen-Styreen(ABS)Dimensions153 x 74 x 28 mm 6.02 x 2.91 x 1.10” (L x W x H)Weight140gr | 4.93ozMounting DIN rail or surface mountedOperation Temperature (Tc)0 to 50°C | 32 to 122°FAmbient Temperature (Ta)40°C | 104°FStorage temperature-20 to 50°C | -4 to 122°FOperating relative humidity90% (indoor use only)IP rating IP10Input Protocols Art-Net 1,2,3 | DMX512 (2 inputs) | DMX RDM (2 inputs) | DiGidot app Output Protocols Art-Net 1,2 & 3 (out/through) | DMX512 (2 outputs) |DMX RDM (2 outputs) | DMX TTL (4 outputs) |47+ SPI protocols (check supported IC’s list)Channels512 / 1024 / 2048 / 4096 Art-Net and/or up to 1024 DMX channels Ethernet RJ45 compatible, for 10/100 Base-TX Ethernet withStatic IP address or DHCPWi-Fi10/100 Base Ethernet with static IP address or DHCPWi-Fi protocols802.11 b/g/n (HT20)Frequency range 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M)TX Power Max. +20 dBmAntenna On boardWiFi Mode Client + APWiFi security WPA, WPA2Encryption WEP/TKIP/AESWiring Max. 2,5 mm2 | 14 AWGConnectors Power: 5-24 Vdc power jack, Art-Net Data: RJ45 bus,IO port: 6-pin Input/Output terminal connectorCompliances CE, listed under No. 2016/119-1, cETL US, listed under No. 5010008, RoHs Applied standards EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013, IEC60950-1 /EN60950-1, EN61006-6-3, EN55032Extended specificationsTechnical drawingsTrigger portMax. 3 dry contacts Max. 3 analog inputs (0-10V, 1-10V, 50 k Ω potentiometer)Digital triggersInternal clock Power up Onboard button Art-Net DMX Http-Get UDP JSON OSCDiGidot C4 web based user interface DiGidot C4 IOS/Google Play app Memory card8 GB Industrial grade microSD card (4 GB for record bu ff er, 4 GB for storing scenes, triggers, playlists, action lists, IO config files, etc.)Supported IC’sFor the various ‘Data’ and ‘Clock+Data’ SPI protocols, following LED Driver IC’s are supported: APA102, APA102_8bit, APA104, APA106, BS0901, DM412, GW6205_400, GW6205_800, INK1003,LD1510, LPD6803, MBI6024, MY9221, MY9231, PC5XS301v0500, SK6812, SK6812RGBW, SM16703, SM16716, SM16726, TM1803, TM1804_400, TM1804_800, TM1809, TM1812, TM1814, TM1914a, UCS1903_400, UCS1903_800, UCS1904, UCS2903, UCS2904, UCS2912, UCS512B3, UCS8904, UCS9812, WES9412, WES943, WS2801, WS2803, WS2811_400, WS2811_800, WS2812, WS2812s, WS2812b, WS2813, WS2818For an up to date overview of supported IC’s visit www.digidot.eu.Please note: In order to use the analog trigger port, the DiGidot TRRS Trigger cable (art. #20903) must be ordered separately.。
摩托罗拉D2811HC, D2811C, D2812C ,D2813C中文说明书
警告:使用前请将子机充电24小时。
D28C 系列适用于: D2811HC, D2811C, D2812C 和 D2813C数字无绳电话机带数字答录机HWDLCD1698(18)P/TSD欢迎您...使用您新购得的Motorola D28C数字无绳电话!• 电话主机可挂在墙上-所有子机请安置于收讯范围内。
• 1.6寸彩色显示屏。
• 可保存100组姓名号码的电话簿。
• 可与其它子机之间复制电话簿条目。
• 时钟屏保。
• 数字录音时间长达12分钟。
• 来电显示功能可显示来电者的身份,您也可在通话记录查看最近30个来电者的详细记录。
1• 一个主机可注册最多4个子机,每个子机可向最多4个不同主机注册。
• 可呼叫内线,转接外线呼叫,在两个内线及一个外线通话者之间进行三方通话。
请注意,本设备不适合在停电时用来拨打紧急电话。
您应备有其它的应急服务联系方式。
需要帮助吗?如果您在D28C的安装或使用上有任何问题,请拨打4008-838-698联系客服部门。
或者,您也可以参阅本手册“疑难解答”章节中的说明。
1您必须先向固话网络运营商申请开通来电显示或来电等待服务,方可享有这些功能。
您可能须支付开通费用。
此用户手册可为您提供一切所需的信息,帮助您充分利用本电话的功能。
要设置您的电话,请遵循后面几页“使用前的准备”中的简单指示。
重要信息仅使用自带的电话线。
下列配件齐全吗?• D28C主机和无绳子机• 2颗镍氢充电电池• 主机的电源适配器• 电话线• 说明书如果您购买的是D28C系列多子机配套,则还将获得以下的额外附件:• 系列子机及充电座• 2颗镍氢充电电池• 充电座的电源适配器1.使用前的准备 (8)2. 认识您的电话 (11)3. 电话功能操作 (18)3.1 启动/关闭子机 (18)3.2 呼叫 (18)3.2.1 拨打电话 (18)3.2.2 预先拨号 (18)3.2.3 结束通话 (18)3.2.4 接听来电 (18)3.3 调节听筒/话筒的音量 (18)3.4 静音模式 (18)3.5 内线通话 (19)3.5.1 呼叫另一个子机 (19)3.5.2 转接通话 (19)3.5.3 三方电话会议 (19)3.6 免提通话 (19)3.6.1 以免提方式拨打电话 (19)3.6.2 以免提方式接听来电 (20)3.7 重拨 (20)3.7.1 从重拨号码列表重拨一个号码 (20)3.7.2 将重拨号码列表中的号码保存至电话簿 (20)3.7.3 删除一个重拨号码/删除全部重拨号码 (20)3.8 锁定键盘 (20)3.9 寻呼/搜索子机 (20)4. 电话簿 (21)4.1 保存名字和电话号码 (21)4.2 在通话期间开启电话簿 (22)4.3 查看电话簿条目 (22)4.4 拨出电话簿条目的号码 (23)4.5 编辑名字和电话号码 (23)4.6 编辑铃声 (23)4.7 删除一个条目 (23)4.8 删除整个电话簿 (23)4.9 将一个条目复制至另一个子机 (24)4.10 将整个电话簿复制至另一个子机 (24)4.11 快速拨号键 (24)4.12 指定 / 清除快速拨号号码 (24)4.13 内存状态 (25)5. 子机设置 (26)5.1 子机铃声 (26)5.2 子机铃声音量 (26)5.3 听筒音量 (26)5.4 子机名称 (26)5.5 语言 (27)5.6 墙纸 (27)5.7 菜单颜色 (27)5.8 屏保 (27)5.9 省电等待时间 (28)5.10 屏幕对比度 (28)5.11 自动接听 (28)5.12 按键音 (29)5.13 PABX前导码 (29)6. 主机设置 (30)6.1 主机铃声 (30)6.2 主机铃声音量 (30)6.3 拨号模式 (30)6.4 响铃优先 (30)6.5 闪断模式 (31)6.6 第一声响铃 (31)6.7 系统PIN码 (31)6.8 恢复默认设置 (32)6.9 默认设置 (33)7. 时间和闹钟 (34)7.1 日期及时间 (34)7.2 设置闹钟 (34)7.3 启动/关闭闹钟 (34)7.4 关闭闹铃 (34)7.5 时间格式 (35)8. 议程提醒 (36)8.1 增加新议程 (36)8.2 关闭提醒铃音 (36)8.3 显示详情 (36)8.4 编辑议程 (37)8.5 删除议程 (37)8.6 删除所有议程 (37)9. 通话记录 (38)9.1 来电显示 (38)9.2 通话记录 (38)9.3 新来电提示 (38)9.4 查看新的未接来电 (38)9.5 从通话记录查看条目及拨号 (38)9.6 将通话记录的号码复制至电话簿 (39)9.7 删除一个条目 (39)9.8 删除全部记录 (39)10. 呼叫等待 (40)11. 宝宝监听 (41)11.1 启动宝宝监听 (41)11.2 改变宝宝监听灵敏度 (41)11.3 设置拨出号码 (41)12. 答录机 (43)12.1 主机控制键 (43)12.2 启动/关闭答录机 (43)12.3 答录延迟 (44)12.4 启动/关闭信息提示音 (44)12.5 屏幕提示 (44)12.6 录制自己的外出留言 (44)12.7 检查或删除您的外出留言 (45)12.8 选择外出留言模式 (46)12.9 录制备忘录 (46)12.10 来电监听 (46)12.11 播放留言 (47)12.12 删除全部旧留言 (47)12.13 启动或关闭遥控操作 (48)12.14 更改遥控操作的PIN码 (48)12.15 遥控启动您的答录机 (48)12.16 从另一个电话操作您的答录机 (49)13. 使用额外子机 (50)13.1 注册额外子机 (50)13.2 选择主机 (50)13.3 取消注册子机 (51)14. 疑难解答 (52)15. 相关信息 (54)1. 使用前的准备警告请勿将电话放置在浴室或其它潮湿之处。
WSS-10扩频微波产品说明书(8E1)
2.1 系统的组成 ..............................................................................................................Байду номын сангаас................... 5 2.2 设备接口 ...................................................................................................................................... 6 2.2.1 中频单元的前面板接口 ....................................................................................................... 6 2.2.2 中频单元的后面板接口 ....................................................................................................... 6 2.2.3 射频单元接口 ....................................................................................................................... 7 2.3 技术指标 ...................................................................................................................................... 7 2.3.1 2.4 G、5.8G 扩频通信产品 RF 单元技术指标 .................................................................. 7 2.3.2 WSS-10/8E1 中频单元技术指标 .......................................................................................... 8 第三章 使用说明................................................................................................................................. 9
WS2811规格书
接收与解码. ● 任意两点传传输距离超过10 米而无需增加任何
电路. ● 当刷新速率30 帧/ 秒时,低速模式级联数不小于
512 点,高速模式不小于1024 点. ● 数据发送速度可达 400Kbps 与800Kbps两种模
式.
基极电阻 RL 可取 5KΩ,NPN 晶体管放大倍数β>150,按上图方法连接电路,MCU 发送的亮度数据和实际 亮度是相反的。
R1 为 IC 内部 LDO 分压电阻(R1=3.8KΩ),104 的电容为旁路电容,IC 的输入与输出端各串入一个 33 的电阻 提供热插拔保护和阻护匹配。
封装图与参数
DIP8 封装:
WS2811
单线 256 级灰度三通道 恒流 LED 驱动 IC
Symbo l A A1 A2 B B1 C D E E1 e L θ
Dimensions In Millmeters
Min
Nom
Max
—
—
4.31
0.38
—
—
3.15
3.40
3.65
0.380.460.源自10.5 µsT1H
1码, 高电平时间
2.0 µs
T0L
0码, 低电平时间
2.0 µs
T1L
1码, 低电平时间
0.5 µs
RES
帧单位,低电平时间
50µs以上
注:当为低速模式时,以上时间翻倍(RESET 码时间不变)
±150ns ±150ns ±150ns ±150ns
1.27
1.52
1.77
0.20
0.25
DINENISO2813_9906
Nationaler LiteraturhinweiseDIN f DIN Deutsches Institut für Normung e.V.Jede Art der Vervielfältigung,auch auszugsweise,nur mit Genehmigung des DIN Deutsches Institut für Normung e.V.,Berlin,gestattet.Alleinverkauf der Normen durch Beuth Verlag GmbH,10772BerlinRef.Nr.DIN EN ISO 2813:1999-06Preisgr.08Vertr.-Nr.2308Klass.Nr: 57650Q U E L L E : N O L I S (N o r m v o r A n w e n d u n g a u f A k t u a l i t ät p r üf e n !)ÐLeerseiteÐG 1999CEN ÐAlle Rechte der Verwertung,gleich in welcher Form und in welchem Verfahren,sind weltweit den nationalen Mitgliedern von CEN vorbehalten.Ref.Nr.EN ISO 2813:1999DEN ISO 2813April 1999Seite 1EN ISO 2813:1999Seite2EN ISO2813:19991AnwendungsbereichDiese Internationale Norm gehört zu einer Reihe von Normen,welche die Probenahme und die Prüfung von Beschichtungsstoffen behandelt.Diese Internationale Norm legt ein Verfahren zum Bestim-men des Reflektometerwertes von Beschichtungen unter den drei Meûgeometrien209,609oder859fest.Das Verfahren ist für die Messung des Glanzes von Metallic-Beschichtungen nicht geeignet.a)Das Verfahren mit der609-Meûgeometrie ist für alleBeschichtungen anwendbar,nur für hochglänzende oder nahezu matte Beschichtungen kann die209-oder die859-Meûgeometrie besser geeignet sein.b)Das Verfahren mit der209-Meûgeometrie,bei dem(imVergleich zur609-Meûgeometrie)ein kleinerer Emp-fänger-Aperturwinkel(Blenden-Aperturwinkel)ange-wendet wird,gestattet eine bessere Differenzierung bei hochglänzenden Beschichtungen(d.h.Beschich-tungen,die bei der609-Meûgeometrie höhere Reflek-tometerwerte als etwa70Einheiten aufweisen).c)Das Verfahren mit der859-Meûgeometrie gestattet einebessere Differenzierung(als mit der609-Meûgeome-trie)bei matten Beschichtungen(d.h.Beschichtungen, die bei der609-Meûgeometrie niedrigere Reflektome-terwerte als etwa10Einheiten aufweisen). ANMERKUNG1:Bei einer Serie von Messungen sollte dieselbe Meûgeometrie beibehalten werden,auch wenn dabei die vorgeschlagenen Grenzwerteüber-bzw.unterschritten werden.ANMERKUNG2:In manchen Fällen entsprechen die ermittelten Reflektometerwerte nicht einer visuellen Bewertung.2Normative VerweisungenDie folgenden Normen enthalten Festlegungen,die,durch Verweisung in diesem Text,Bestandteil dieser Internatio-nalen Norm sind.Zum Zeitpunkt der Veröffentlichung dieser Norm waren die angegebenen Ausgaben gültig. Alle Normen unterliegen derÜberprüfung.Vertragspartner, deren Vereinbarungen auf dieser Internationalen Norm basieren,werden gebeten,zu prüfen,ob die jeweils neue-sten Ausgaben der im folgenden genannten Normen angewendet werden können.Die Mitglieder von IEC und ISO führen Verzeichnisse der gegenwärtig gültigen Inter-nationalen Normen.ISO1512:1991Paints and varnishesÐSampling of products in liquid or paste formISO1513:1992Paints and varnishesÐExamination and preparation of samples for testingISO2808:1991Paints and varnishesÐDetermination of film thick-ness3BegriffFür diese Internationale Norm gilt die folgende Definition: 3.1Reflektometerwert:Das Verhältnis der von einer Probe und einer Glasoberfläche mit der Brechzahl1,567in Spiegelrichtung reflektierten Lichtströme.Dabei wird von definierten Aperturwinkeln der Lichtquelle und des Emp-fängers ausgegangen.ANMERKUNG3:Zur Definition der Reflektometerwertska-le wird für poliertes Schwarzglas mit einer Brechzahl von1,567der Wert100für die209-,609-und 859-Meûgeometrie festgelegt.4Erforderliche zusätzliche AngabenFür die Anwendung muûdas in dieser Internationalen Norm festgelegte Prüfverfahren durch eine Reihe von Angaben vervollständigt werden;siehe Anhang A.5GerätÜbliches Labor-und Glasgerät,zusammen mit:5.1Substrat zum Prüfen vonflüssigen BeschichtungsstoffenDas Substrat muûGlas von Spiegelglasqualität sein,vor-zugsweise mit einer Dicke von mindestens3mm und Mindestmaûen von150mm6100mm.Die gröûte Abmes-sung muûmindestens gleich der Länge der beleuchteten Fläche sein.ANMERKUNG4:Obwohl das beschriebene Verfahren auf pigmentierte Beschichtungsstoffe beschränkt ist,kön-nen auch Klarlacke geprüft werden,wenn als Substrat schwarzes Glas verwendet wird.Es kann auch auf-gerauhtes Klarglas benutzt werden,wenn die Rück-seite und die Kanten schwarz beschichtet werden.VorwortDer Text der Internationalen Norm vom Technischen Komitee ISO/TC35¹Paints and varnishes``der International Organization for Standardization(ISO)wurde als Europäische Norm durch das Technische Komitee CEN/TC139¹Lacke und Anstrichstoffe``übernommen,dessen Sekretariat vom DIN gehalten wird.Diese Europäische Norm muûden Status einer nationalen Norm erhalten,entweder durch Veröffentlichung eines identischen Textes oder durch Anerkennung bis Oktober1999,und etwaige entgegenstehende nationale Normen müssen bis Oktober1999zurückgezogen werden.Entsprechend der CEN/CENELEC-Geschäftsordnung sind die nationalen Normungsinstitute der folgenden Länder gehalten,diese Europäische Norm zuübernehmen:Belgien,Dänemark,Deutschland,Finnland,Frankreich,Griechenland,Irland,Island,Italien,Luxemburg,Niederlande, Norwegen,Österreich,Portugal,Schweden,Schweiz,Spanien,die Tschechische Republik und das Vereinigte Königreich.AnerkennungsnotizDer Text der Internationalen Norm ISO2813:1994,einschlieûlich Technisches Korrigendum1:1997,wurde von CEN als Europäische Norm ohne irgendeine Abänderung genehmigt.ANMERKUNG:Die normativen Verweisungen auf Internationale Normen sind im Anhang ZA(normativ)aufgeführtSeite3EN ISO2813:1999 5.2FilmziehgerätEin Filmaufziehrahmen mit einer Spalthöhe von(150+2)m m auf einer optisch ebenen Fläche oder andereGeräte zum Auftragen eines Beschichtungsstoffes sind zuverwenden.ANMERKUNG5:Mit dem Filmaufziehrahmen wird eineFlüssigschichtdicke(Naûschichtdicke)von etwa75m merreicht.5.3ReflektometerDas Reflektometer muûaus einer Lichtquelle und einerLinse bestehen,die einen parallelen Lichtstrahl auf die zuprüfende Oberfläche richtet,und weiter aus einem Emp-fängergehäuse,das eine Linse,eine Blende und einenPhotoempfänger enthält,um das reflektierte Lichtbündelaufzunehmen.Das Reflektometer muûdie folgendenMerkmale aufweisen:a)GeometrieDer Einfallsstrahl muûunter einem Winkel von(20+0,1)9,(60+0,1)9oder(85+0,1)9(siehe Tabelle1)zur Senk-rechten auf die zu prüfende Oberfläche fallen.Die optischeAchse des Empfängers muûmit dem Spiegelbild der Achsedes Einfallsstrahles mit einer zulässigen Abweichung von+0,19zusammenfallen.Mit einem ebenen polierten StückSchwarzglas oder einem Oberflächenspiegel anstelle derProbenplatte muûdie Lichtquelle in der Mitte der Empfän-gerblende(des Empfängerfensters)abgebildet werden(siehe Bild1mit den wesentlichen Merkmalen).Zum Mit-telnüber die gesamte Oberfläche muûdie Breite derbeleuchteten Fläche der Probenplatte wesentlich gröûersein als eventuell vorhandene Oberflächenstrukturen:einallgemein anerkannter Wert ist10mm.Die Maûe und die zulässigen Abweichungen der Licht-quellen-und der Empfängerapertur müssen den Angabenin Tabelle1entsprechen.Die Winkelmaûe der Empfän-gerblende müssen von der Empfängerlinse aus gemessenwerden.b)Filterung am EmpfängerDie Filterung am Empfänger muûso geschehen,daûderTransmissionsgrad t(l)des Filters durch die Gleichungt l k V l ´S C l s l ´S s lgegeben ist.Dabei ist:V(l)spektraler Hellempfindlichkeitsgrad;S C(l)spektrale Strahlungsverteilung der CIE-Normlicht-art C;s(l)spektrale Empfindlichkeit des Empfängers;S s(l)spektrale Strahlungsverteilung der Lichtquelle;k Kalibrierungskonstante.ANMERKUNG6:Die zulässigen Abweichungen sind so gewählt,daûFehler in der Lichtquellen-und Emp-fängerapertur einen Ablesefehler von höchstens einer Einheit an jeder Stelle der100-Einheiten-Skale(siehe5.4.1)hervorrufen.Nach Vereinbarung darf für eineÜbergangszeit auch die CIE-Normlichtart A angewendet werden.Dies ist im Prüf-bericht anzugeben.c)VignettierungStrahlen,die innerhalb der in5.3a)festgelegten Winkel-bereiche liegen,dürfen nicht beschnitten werden.d)EmpfängermeûgerätDie Meûvorrichtung des Empfängers muûeinen Anzeige-wert liefern,der proportional dem Lichtstrom durch die Empfängerblende ist,wobei die Abweichung höchstens 1%vom Vollausschlag betragen darf. ANMERKUNG7:Eineübliche Meûanordnung verwendet ein Sperrschichtphotoelement in Verbindung mit einem hochohmigen Galvanometer.Diese Anordnung reicht so nicht aus,weil sie deutlich nichtlinear ist.Dieser Mangel kann aber durch einen elektronischen Verstär-ker mit geringer Eingangsimpedanz,der zwischen Photoelement und Galvanometer geschaltet ist,aus-geglichen werden.Das Gerät muûauûerdem eine Empfindlichkeitsregelung besitzen,mit der der Strom des Photoelements auf jeden gewünschten Wert auf der Skale des Gerätes eingestellt werden kann.5.4Standards5.4.1PrimärstandardDer Primärstandard muûaus hochglanzpoliertem Quarz-glas oder Schwarzglas bestehen.Die Oberfläche muûso eben sein,daûje cm nur zwei Ringe auftreten,wenn sie mit optischen Interferenzverfahren vermessen wird. ANMERKUNG8:Primärstandards sollen nicht für die tägliche Kalibrierung des Reflektometers verwendet werden.Glas mit einer Brechzahl von1,567,gemessen bei einer Wellenlänge von587,6nm,wird ein Reflektometerwert von 100zugeordnet.Glas mit einer anderen Brechzahl erfor-dert eine Korrektur.Für poliertes Quarzglas und Schwarz-glas mit verschiedenen Brechzahlen sind die Reflektome-terwerte bei den drei Einfallswinkeln in Tabelle2 angegeben.Der Primärstandard muûwegen einer möglichen Alte-rung mindestens alle zwei Jahre geprüft werden.Dies gilt besonders für Schwarzglas.Im Falle einer Ver-schlechterung kann der ursprüngliche Reflektometerwert durch optisches Polieren mit Ceroxid wieder hergestellt werden.ANMERKUNG9:Das am leichtesten erhältliche Glas der geforderten Planarität wird zur Zeit nach dem¹Float``-Verfahren hergestellt.Dieses Glas ist für die Verwen-dung als Primärstandard ungeeignet,weil die Brech-zahl im Innern des Glases von derjenigen der Glasoberfläche abweicht.Vorzugsweise ist ein optisch ebenes Glas zu verwenden,das nach anderen Ver-fahren hergestellt ist,oder es ist die oberste Schicht des Floatglases zu entfernen und optische Planarität durch Polieren herzustellen.ANMERKUNG10:Die Brechzahl sollte mit einem Abbe-Refraktometer bestimmt werden.ANMERKUNG11:Falls der absolute Reflexionsgrad des Primärstandards gefordert ist,kann die Fresnelsche Gleichung angewendet werden,wobei die Brechzahl des Standards in die Gleichung eingesetzt wird.5.4.2ArbeitsstandardsDie Arbeitsstandards können aus Keramikplatten,Emaille, Milchglas,poliertem Schwarzglas oder anderen Materia-lien mit einheitlichem Glanz bestehen.Sie müssen jedoch plan sein und für eine bezeichnete Fläche und eine definierte Beleuchtungsrichtung gegen einen Primärstan-dard kalibriert sein.Die Arbeitsstandards müssen homo-gene Oberflächen besitzen und stabil sein.Sie müssen durch eine technisch kompetente Institution kalibriert werden.Für jede Meûgeometrie müssen mindestens zwei Standards mit unterschiedlichen Reflektometerwer-ten verfügbar sein.Die Arbeitsstandards sind regelmäûig mit Primärstandards zu vergleichen.Seite4EN ISO2813:1999Tabelle1:Winkel und relative Maûe von Lichtquellen-und EmpfängeraperturParameterParallel zur Meûebene1)Senkrecht zur MeûebeneWinkel s2)2tan s/2relatives MaûWinkel s2)2tan s/2relatives MaûLichtquellen-Apertur0,759+0,190,0131+0,00180,171+0,0232,59+0,190,0436+0,00180,568+0,023Empfänger-Apertur(209-Geometrie)1,809+0,0590,0314+0,00090,409+0,0123,69+0,190,0629+0,00180,819+0,023Empfänger-Apertur(609-Geometrie)4,49+0,190,0768+0,00181,000+0,02311,79+0,290,2049+0,00352,668+0,046Empfänger-Apertur(859-Geometrie)4,09+0,390,0698+0,00520,909+0,0686,09+0,390,1048+0,00521,365+0,0681)Die Empfänger-Apertur in der Meûebene der609-Geometrie wurde als Einheit genommen.2)Lichtquellen-Aperturwinkel:s S;Empfänger-Aperturwinkel:s BG=LichtquelleL1und L2=LinseB=EmpfängerblendeP=Beschichtunge1=e2s B=Empfänger-Aperturwinkels S=Lichtquellen-AperturwinkelI=Bild der LichtquelleBild1:Schema eines Reflektometers(Schnitt in der Meûebene)Seite5EN ISO2813:1999 Tabelle2:Reflektometerwerte für poliertes Quarzglas und SchwarzglasBrechzahlnEinfallswinkel2096098591,400 1,410 1,420 1,430 1,440 1,450 1,460 1,470 1,480 1,490057,0059,4061,8064,3066,7069,2071,8074,3076,9079,5071,9073,7075,5077,2079,0080,7082,4084,1085,8087,5096,6096,9097,2097,5097,6098,0098,2098,4098,6098,81,500 1,510 1,520 1,530 1,540 1,550 1,560 01,5671)082,0084,7087,3090,0092,7095,4098,10100,01)089,1090,8092,4094,1095,7097,3098,90100,01)099,0099,2099,3099,5099,6099,8099,90100,01)1,570 1,580 1,590100,8103,6106,3100,5102,1103,6100,0100,2100,31,600 1,610 1,620 1,630 1,640 1,650 1,660 1,670 1,680 1,690109,1111,9114,3117,5120,4123,2126,1129,0131,8134,7105,2106,7108,4109,8111,3112,8114,3115,8117,3118,8100,4100,5100,6100,7100,8100,9100,9101,0101,1101,21,700 1,710 1,720 1,730 1,740 1,750 1,760 1,770 1,780 1,790137,6140,5143,4146,4149,3152,2155,2158,1161,1164,0120,3121,7123,2124,6126,1127,5128,9130,4131,8133,2101,2101,3101,3101,4101,4101,5101,5101,6101,6101,61,800167,0134,6101,7 1)PrimärstandardSeite6EN ISO2813:19995.4.3NullstandardZur Nullpunktkontrolle des Reflektometers ist ein geeigne-ter Standard(z.B.schwarzer Samt,schwarzer Filz oder ein geschwärzter Hohlkörper)zu verwenden.6Probenahme von flüssigenBeschichtungsstoffenEine repräsentative Probe von dem zu prüfenden Beschichtungsstoff(oder aus jedem Beschichtungsstoff im Falle eines Mehrschichtsystems)nehmen,wie in ISO1512beschrieben.Jede Probe nach ISO1513vorprüfen und für die weitere Prüfung vorbereiten.7Probenahme von beschichtetenSubstratenEine ebene Fläche des beschichteten Substrates nehmen, möglichst mit den Mindestmaûen150mm6100mm. ANMERKUNG12:Messungen des Reflektometerwertes nach dieser Internationalen Norm sind nur aussage-fähig,wenn sie auf ebenen Oberflächen ausgeführt werden;jede Krümmung oder Unebenheit des Sub-strates wirkt sich auf die Prüfergebnisse aus.8Herstellen von Probenplatten8.1Flüssige Beschichtungsstoffproben8.1.1Herstellen von ProbenbeschichtungenDen Beschichtungsstoff vorzugsweise in derüblichen Art und Schichtdicke nach dem festgelegten oder vereinbar-ten Verfahren auftragen,z.B.durch Streichen,Rollen oder Spritzen(siehe Abschnitt4und Anhang A).Falls kein Verfahren festgelegt oder vereinbart ist,oder in Schiedsfällen,wie folgt verfahren:Bei den Beschichtungsstoffproben unmittelbar vor dem Auftragen durch kräftiges Rühren thixotrope Strukturen abbauen.Darauf achten,daûkeine Luftblasen einge-schlossen werden.Jeden Beschichtungsstoff mit einer Ergiebigkeit von etwa15m2/l auf ein frisch entfettetes Substrat(5.1)auftragen.Dazu etwa2m l Beschichtungs-stoff in einer Linie am Ende der Glasplatte auftragen und mit dem Filmziehgerät(5.2)zu einer gleichmäûigen Beschichtung aufziehen,indem das Gerät mit einer Geschwindigkeit von etwa100mm/s mit festem Druck über die Platte gezogen wird.Die Beschichtungen auf den Probenplatten bei(23+2)9C und(50+5)%relativer Luftfeuchteüber die festgelegte oder eine geeignete Zeit-spanne trocknen(oder einbrennen).Vor dem Messen des Reflektometerwertes die Beschichtungen16h bei der gleichen Temperatur und Luftfeuchte konditionieren, ohne sie direktem Sonnenlicht auszusetzen.Die Prüfung sobald wie möglich nach dem Konditionieren durchführen.8.1.2SchichtdickenmessungDie Trockenschichtdicke der Beschichtung,in m m,nach einem der in ISO2808festgelegten Verfahren bestimmen.8.2Beschichtungen auf Substraten8.2.1AllgemeinesDie Richtung von Pinselfurchen,erkennbare Holzmase-rungen oderähnliche Strukturen müssen parallel zur Einfalls-und Reflexionsrichtung des Lichtstrahls des Gerä-tes liegen.8.2.2SchichtdickenmessungDie Trockenschichtdicke der Beschichtung,in m m,nach einem der in ISO2808festgelegten Verfahren bestimmen.9Kalibrieren des Reflektometers9.1Vorbereiten des GerätesZu Beginn jeder Meûreihe und zwischen den Messungen das Gerät in ausreichend häufigen Zeitabständen kalibrie-ren,um sicherzustellen,daûdie Anzeige des Gerätes ausreichend konstant ist.9.2NullpunktkontrolleZur Kontrolle des Nullpunktes den Nullstandard(5.4.3) verwenden.Erscheint die Anzeige nicht innerhalb von +0,1vom Nullpunkt,die Abweichung bei den nachfolgen-den Messungen abziehen.9.3KalibrierenDas Gerät mit einem Arbeitsstandard,der einen Reflekto-meterwert nahe100hat,auf den entsprechenden Reflek-tometerwert einstellen,wobei sich der Zeiger im oberen Bereich der Skale befinden soll.Danach einen Arbeitsstandard mit niedrigerem Reflekto-meterwert verwenden und eine Messung mit den gleichen Einstellungen durchführen.Weicht der angezeigte Wert für diesen Arbeitsstandard um weniger als einen Skalenteil von dem ihm zugeordneten Reflektometerwert ab,ist die Proportionalitätsforderung von 5.3d)erfüllt.Liegt der angezeigte Wert jedoch auûerhalb dieser Toleranz,eine zusätzliche Messung mit einem weiteren Arbeitsstandard durchführen.Weichen beide Werte um mehr als einen Skalenteil von den zugeordneten Reflektometerwerten ab, muûdas Reflektometer durch den Gerätehersteller oder entsprechend den Anweisungen des Herstellers justiert werden.Der Kalibrierungsvorgang ist zu wiederholen,bis die Arbeitsstandards mit der geforderten Genauigkeit gemessen werden können.Wenn die hierbei gemessenen Werte um nicht mehr als einen Skalenteil abweichen, können die Prüfungen durchgeführt werden.Vor jeder Bestimmung ist jedoch die Kalibrierung nochmals zu prüfen.10Durchführung10.1Messungen des Reflektometerwertes vonBeschichtungen,die(nach dieser Norm)aus flüssigen Beschichtungsstoffenhergestellt wurdenNach dem Kalibrieren des Reflektometers die Beschich-tungen auf Glasplatten an3unterschiedlichen Stellen parallel zur Auftragsrichtung messen.Dabei nach jeder Meûreihe den Wert des Arbeitsstandards mit höherem Reflektometerwert prüfen,um sicherzustellen,daûsich die Kalibrierung nicht verändert hat.Beträgt die Streuung weniger als5Einheiten,den Mittelwert als Reflektometer-wert angeben,anderenfalls3weitere Messungen durch-führen und den Mittelwert aller6Werte sowie den Bereich der Meûwerte angeben.Für Messungen an Beschichtungen auf anderen Substra-ten als Glas6Messungen ausführen,je3in zwei recht-winklig zueinander stehenden Richtungen,und den Mittel-wert sowie den Bereich der Meûwerte angeben.Nach3 Messungen den Wert des Arbeitsstandards mit höherem Reflektometerwert prüfen,um sicherzustellen,daûsich die Kalibrierung nicht verändert hat.Seite7 EN ISO2813:199910.2Messung des Reflektometerwertes beianderen Beschichtungen(nicht nachdieser Norm hergestellt)Wie in10.1verfahren,dabei6Messungen in unterschied-lichen Bereichen oder in verschiedenen Richtungen auf der Oberfläche ausführen(ausgenommen bei Beschich-tungen mit in einer Richtung laufenden Strukturen,z.B. Pinselfurchen).Nach3Messungen den Wert des Arbeits-standards mit höherem Reflektometerwert prüfen,um sicherzustellen,daûsich die Kalibrierung nicht verändert hat.Den Mittelwert der6Messungen berechnen.Wenn die Abweichung zwischen dem gröûten und dem kleinsten Meûwert weniger als10Einheiten oder20%des Mittel-wertes beträgt,Mittelwert und Bereich der Meûwerte angeben.Anderenfalls die Probenplatte verwerfen.11Präzision(nur für Beschichtungen auf Glasplatten)11.1WiederholbarkeitDie Wiederholbarkeit r ist der Wert,unterhalb dessen die absolute Differenz zwischen den Mittelwerten von 2getrennten Serien von je3Messungen an einer Beschichtung auf einer Glasplatte bei der Anwendung dieses Prüfverfahrens unter Wiederholbedingungen erwartet werden kann.Dabei werden die Messungen von demselben Prüfer in demselben Laboratorium innerhalb einer kurzen Zeitspanne nach dem genormten Prüfver-fahren durchgeführt.Nach dieser Norm beträgt r1Einheit für die609-und die859-Meûgeometrie und2Einheiten für die209-Meûgeometrie,mit einer Wahrscheinlichkeit von 95%.11.2VergleichbarkeitDie Vergleichbarkeit R ist der Wert,unterhalb dessen die absolute Differenz zwischen den Mittelwerten von 2getrennten Serien von je3Messungen an einer Beschichtung aus demselben Beschichtungsstoff auf einer Glasplatte bei der Anwendung dieses Prüfverfahrens unter Vergleichbedingungen erwartet werden kann.Dabei werden die Messungen von unterschiedlichen Prüfern in unterschiedlichen Laboratorien nach dem genormten Prüf-verfahren durchgeführt.Nach dieser Norm beträgt R6,4 bzw.7Einheiten für die209-,609-bzw.859-Meûgeometrie, mit einer Wahrscheinlichkeit von95%.Bei einigen Beschichtungsstoffen,speziell bei halbglän-zenden,ist der Reflektometerwert empfindlich gegenüber Veränderungen bei den Trocknungs-/Härtungsbedingun-gen und dem Beschichtungsverfahren.Die Vergleichbar-keit der Ergebnisse ist bei solchen flüssigen Beschich-tungsstoffen schlechter als vorstehend angegeben.Wenn in Schiedsfällen die Reflektometerwerte um mehr als10% voneinander abweichen,müssen hergestellte Beschich-tungen zwischen den Laboratorien ausgetauscht werden.12PrüfberichtDer Prüfbericht muûmindestens die folgenden Angaben enthalten:a)alle Einzelheiten,die zum Kennzeichnen des geprüftenBeschichtungsstoffes notwendig sind;b)einen Hinweis auf diese Internationale Norm(ISO2813);c)die Einzelheitenüber Angaben entsprechendAnhang A;d)einen Hinweis auf die internationale oder nationaleNorm,die Produktspezifikation oder ein anderes Schriftstück,die(das)die Angaben nach c)enthält;e)verwendeten Einfallswinkel;f)Ergebnisse der Prüfung,wie im Abschnitt10angege-ben;g)jede Abweichung von dem festgelegten Prüfverfahren;h)Prüfdatum.Seite8EN ISO2813:1999Anhang A(normativ)Erforderliche zusätzliche AngabenDamit die Prüfung durchgeführt werden kann,sind zur Vervollständigung zu den in diesem Anhang aufgeführten Punkten Angaben erforderlich.Diese Angaben sollten vorzugsweise zwischen den Vertragspartnern vereinbart werden.Sie können teilweise oder vollständig einer internationalen oder nationalen Norm oder einem anderen Schriftstück für den zu prüfenden Beschich-tungsstoff entnommen werden.a)Substrat(einschlieûlich Dicke)und seine Oberflächenvorbereitung;b)Verfahren zum Beschichten des Substrates;ANMERKUNG13:Auftragen durch Streichen kann zu variablen Reflektometerwerten führen.c)Dauer und Bedingungen für das Trocknen/Härten(einschlieûlich Einbrennen)der Beschichtung und gegebenenfallsAlterungsbedingungen vor dem Prüfen;d)Trockenschichtdicke der Beschichtung,in m m,einschlieûlich Meûverfahren nach ISO2808und Angabe,ob es sich umeine einzelne Schicht oder um ein Mehrschichtsystem handelt.Anhang B(informativ)LiteraturDie folgende Norm enthält nützliche Angabenüber die Bestimmung des Reflektometerwertes von anderen Materialien als Beschichtungen:[1]ISO7668:1986,Anodized aluminium and aluminium alloysÐMeasurement of specular reflectance and specular glossat angles of20degrees,45degrees,60degrees or85degrees.Anhang ZA(normativ)Normative Verweisungen auf internationale Publikationen mit ihren entsprechenden europäischen PublikationenDiese Europäische Norm enthält,durch datierte oder undatierte Verweisungen,Festlegungen aus anderen Publikationen. Diese normativen Verweisungen sind an den jeweiligen Stellen im Text zitiert,und die Publikationen sind nachstehend aufgeführt.Bei datierten Verweisungen gehören spätere¾nderungen oderÜberarbeitungen dieser Publikationen nur zu dieser Europäischen Norm,falls sie durch¾nderung oderÜberarbeitung eingearbeitet sind.Bei undatierten Verweisungen gilt die letzte Ausgabe der in Bezug genommenen Publikation.Publikation Jahr Titel EN JahrEN215121994 ISO15121991Paints and varnishesÐSampling of products in liquid orpaste formISO15131992Paints and varnishesÐExamination and preparation ofEN ISO15131994samples for testing。
Wilsonart Traceless Laminate 型号 138 和 738 产品说明书
TECHNICAL DATAWilsonart® Traceless™ Laminate1.ManufacturerWilsonart LLC2501 Wilsonart DriveP.O. Box 6110Temple, Texas 76503-6110Phone: (254) 207-7000; (800) 433-3222Fax: (254) 207-2384Web Site: 2.Product DescriptionRecommended UsesWilsonart® Traceless™ Laminate, Type 138, is suitable for use on retail, office furniture,manufactured housing, hospitality, casework, countertops, and interior doors and also forarchitectural application on wainscoting, valances, and divider systems.•Type 138 Common applications are for counters, desktops, cabinet doors and drawer panels.Type 138 is intended for use on vertical and horizontal interior surfaces.•Type 738 Traceless™ with RE-COVER™ Common applications are suitable for use in retail, office furniture, manufactured housing, hospitality, casework, countertops, and interior doors and also for architectural application on wainscoting, valances and divider systems.Product CompositionDecorative surface papers impregnated with resins that are pressed over kraft paper core sheets impregnated with phenolic resin. These sheets are then bonded at pressures greater than 1000 pounds per square inch at temperatures approaching 300°F (149°C). Finished sheets are trimmed, and the backs are sanded to facilitate bonding.Due to the composition of Traceless, light scratches can be removed using a white melamine foam eraser, ex: Mr. Clean Magic Eraser.Basic LimitationsWilsonart® Traceless™ Laminate is for interior use only and is not recommended for direct application to plaster, concrete walls, or gypsum wallboard. It is not structural material and must be bonded to a suitable substrate. Traceless™ Laminate is a non-post formable product.Do not subject Wilsonart® Traceless™ Laminate to extremes in humidity, temperatures higher than 275°F (135°C) for substantial periods of time, or intense, continuous, direct sunlight.Patterns & ColorsAvailable in the full range of Wilsonart solid colors and woodgrains. See all patterns and colors at . Please see actual sample before specifying.Finish Availability•#31 Traceless™ Finish - A smooth textured finish with moderate reflective value.Nominal Glossometer Reading = 2.5#31 finish is designated for Wilsonart® Traceless™ Laminate only.NOTE: Nominal Glossometer Readings are made at a 60° angle of incidence.Standard Sheet Sizes48" x 96" (1219mm x 2438mm)48" x 120" (1219mm x 3048mm)60” x 144” (1524mm x 3658mm)Thickness and WeightDescription 138Thickness 0.039” ± 0.005”(0.99mm ± 0.13mm)Weight per square foot 0.260#3.Technical DataPhysical Properties of Wilsonart® Traceless™ LaminatesISO 4586 Test Typical WilsonartType 138 ISO 4586-8Thickness 0.039” ± 0.005”(0.99mm ± 0.13mm) 0.039” ± 0.005” (1mm ± 0.12mm)Appearance No ABC def. Not applicable. Light Resistance Slight effect Slight effect Cleanability (cycles) 20 20 Stain ResistanceReagents 1-10 Reagents 11-15No effectSlight effect (Light colors)No effectModerate effectBoiling Water Resistance No Effect Slight Effect (Gloss)No Effect (Other Finishes)High Temperature Resistance No Effect Slight Effect (Gloss)No Effect (Other Finishes) Impact Resistance 45” (1143mm) 31.5” (800mm) Radiant Heat Resistance 235 seconds > 200 sec. Dimensional Stability (Elevated)Machine Direction Cross Direction 0.3%0.7%0.55% (max.)0.95% (max.)Dimensional Stability (Ambient)Machine Direction Cross Direction 0.3%0.7%0.50% (max.)0.90% (max.)Surface Wear Resistance (cycles) Meets or Exceeds 350 cycles 350 (min.) Formability* Not applicable Not ApplicableTypical Fire Test DataHigh-pressure laminates are subject to Flame Spread and Smoke Developed standards in structures where codes establish such conditions.Test data to determine compliance with these codes are obtained by the Steiner Tunnel Test method of the American Society for Testing Materials (ASTM-E-84, Standard Test Method for Surface Burning Characteristics of Building Materials). Tests were conducted in accordance with test method and mounting procedure as described in paragraph X1.7.2 of the test method. This procedure is cataloged by Underwriters Laboratories, Inc. as UL 723.Typical Flame Spread and Smoke Developed PropertiesProduct Type Test Condition Flame Spread Smoke Developed Type 138 Unbonded 80 60Model Code Designations used to determine flame spread classificationFlame Spread Classification (Max. Rating) International(IBC)Life Safety (NFPA 101)25A A 75B B 200CCRE: Architectural Woodwork Quality Standard, 8th Edition, Version 1.0, - 2003All Model Codes regulate the generation of smoke by interior finish material. In all cases they specify a maximum smoke development rating of 450.Codes and CertificationsGeneral StandardsWilsonart® Traceless™ Laminate, type 138, conforms to the voluntary standards of the American National Standards Institute, for thickness, performance properties and appearance. Traceless™ Laminate, Type 138 meets or exceed the International Standards Organization specifications as found in ISO 4586-8, titled “High-Pressure Decorative Laminate (HPDL) – Sheets Based on Thermosetting Resins – Part I: specifications.”Specific Product StandardsThe UL GREENGUARD Environmental Institute™ has awarded its UL GREENGUARD ® Indoor AirQuality Certification to Wilsonart® Traceless™ Laminate. All Wilsonart® Laminate product types were tested under the stringent UL GREENGUARD Standards for low-emitting products. All UL GREENGUARD Indoor Air Quality Certified products ensure minimal impact on the indoor environment. For a copy of the certificate, visit .All patterns meet SEFA 8-PL testing requirements.Branded Cleaner and Sanitizer Resistance for Wilsonart® Traceless™ Laminate per ISO 4586-2 Method 31 (B)No effect was exhibited except as noted (* or **) on the following:1. Beckart Environmental (Stabilized Chlorine Dioxide Mixed with Water at 3000ppm)2. Benefect® *3. Claire® Germicidal Cleaner (Country Fresh Scent)4. Claire® Disinfectant Spray Q (Country Fresh Scent)5. Clean Republic – All Purpose Everyday Cleaner (Hypochlorous Acid – 0.003% Solution)6. Clorox® Anywhere® Hard Surface Sanitizing Spray*7. Clorox® Clean-Up (Cleaner & Bleach)8. Clorox® Disinfecting Bleach w/6% Sodium Hypochlorite (24:1/Water:Bleach) 9. Clorox® Disinfecting Spray 10. Clorox® Disinfecting Wipes11. Clorox Healthcare® Bleach Germicidal Cleaner *12. Clorox Healthcare® Hydrogen Peroxide Cleaner Disinfectant * 13. Clorox Healthcare® Fuzion® Cleaner Disinfectant*14. Clorox Healthcare® VersaSure® Cleaner Disinfectant Wipes 15. Clorox® Total 360 Disinfectant Cleaner 16. Diversey™ Expose® II 256 ** 17. Diversey™ Oxivir 1 *18. Diversey™ Oxivir Tb Wipes *19. Diversey™ Stride® Floral Neutral Cleaner 20. Diversey™ Virex® II 256 *21. Fabuloso® Complete (Multi-Purpose Cleaner) 22. Lysol® Professional Disinfectant Spray23.Microban® 24 Hour (Multi-Purpose Cleaner)24.PDI Sani-Prime® Germicidal Spray25.PDI Super Sani-Cloth® Germicidal Disposable Wipes26.Purell® Advanced Hand Sanitizer Gel27.Purell® Food Service Surface Sanitizer28.Purell® Professional Surface Disinfectant29.Purell® Healthcare Surface Disinfectant30.Simple Green® Concentrated (All-Purpose Cleaner)31.Spic and Span® Everyday (Antibacterial Cleaner)Test procedure: Listed materials were placed in contact with Wilsonart® Traceless™ Laminate surface under 1" (25.4mm) diameter watch cover glass for 16 hours duration prior to evaluation for effect. The branded cleaners and sanitizers listed above were cleaned with water only.* Causes slight change of gloss or color.** Causes slight damage, with degree of damage proportionate to length of exposure and concentration.Branded Cleaner and Sanitizer Resistance for Wilsonart® Traceless™ Laminate per BIFMA HCF 8.1-2014 (Section 6 / Modified)No effect was exhibited except as noted (* or **) on the following:1.Beckart Environmental, Inc. (Stabilized Chlorine Dioxide Mixed with Water at 3000ppm)2.Benefect®3.Claire® Germicidal Cleaner (Country Fresh Scent)4.Claire® Disinfectant Spray Q (Country Fresh Scent)5.Clean Republic – All Purpose Everyday Cleaner (Hypochlorous Acid – 0.003% Solution)6.Clorox® Anywhere® Hard Surface Sanitizing Spray7.Clorox® Clean-Up (Cleaner & Bleach)8.Clorox® Disinfecting Bleach w/6% Sodium Hypochlorite (24:1/Water:Bleach)9.Clorox® Disinfecting Spray10.Clorox® Disinfecting Wipes11.Clorox Healthcare® Bleach Germicidal Cleaner12.Clorox Healthcare® Hydrogen Peroxide Cleaner Disinfectant13.Clorox Healthcare® Fuzion® Cleaner Disinfectant14.Clorox Healthcare® VersaSure® Cleaner Disinfectant Wipes15.Clorox® Total 360 Disinfectant Cleaner16.Diversey™ Expose II 25617.Diversey™ Oxivir 118.Diversey™ Stride® Floral Neutral Cleaner19.Diversey™ Tb Wipes20.Diversey™ Virex II 25621.Fabuloso® Complete (Multi-Purpose Cleaner)22.Lysol® Professional Disinfectant Spray23.Microban® 24 Hour (Multi-Purpose Cleaner)24.PDI Sani-Prime® Germicidal Spray25.PDI Super Sani-Cloth® Germicidal Disposable Wipes26.Purell® Advanced Hand Sanitizer Gel27.Purell® Food Service Surface Sanitizer28.Purell® Professional Surface Disinfectant29.Purell® Healthcare Surface Disinfectant30.Simple Green® Concentrated (All-Purpose Cleaner)31.Spic and Span® Everyday (Antibacterial Cleaner)Test procedure: Listed reagent materials were placed in contact with Wilsonart® Traceless™ Laminate surface with a one-inch square 100% cotton cloth completely saturated and covered with a 2”(50.8mm) diameter watch cover glass for 15 minute duration. The reagents listed above wereremoved with clean cloth and the area was then cleaned with clean cloth and distilled water only. The surface area was allowed to dry for 1-hour prior to evaluation for effect.* Causes slight change of gloss or color.** Causes slight damage, with degree of damage proportionate to length of exposure andconcentration.Resistance of Furniture to UV Lights for Wilsonart® Traceless™ Laminate per BIFMA HCF 8.1-201X Section 9 (Alternate Method per ASTM G155 using ISO 4586-2.33 conditions)Wilsonart Laminates 107,335,350 and 376 conforms to BIFMA – Healthcare Furniture DesignGuidelines for Cleanability , Section 9 Resistance to Furniture to UV Lights. Wilsonart Laminates 107, 335, 350 and 376 meet or exceed the acceptance level for surface evaluation.4.Installation: Fabrication and Assembly RecommendationsFabrication should follow approved methods. Assembled pieces should meet the specifications of KCMA (Kitchen Cabinetmakers Manufacturers Association), ANSI A-161.2-1998 (revised), and“Architectural Woodwork Quality Standards, Guide Specifications and Quality Certification Program”guidelines of the Architectural Woodwork Institute where applicable.Wilsonart® Traceless™ Laminate must be bonded to a substrate of reliable quality, such asparticleboard, medium density fiberboard or plywood with one A-face. High-pressure laminate, plaster, concrete and gypsum board should not be considered suitable substrates. Basic Types laminate may not be used as structural members.Bond with adhesives and follow the techniques recommended by the adhesive manufacturer.Recommended adhesives are permanent types, such as urea and polyvinyl acetate (PVA), andcontact types. Wilsonart® Adhesives are recommended for most bonding conditions.To avoid stress cracking, do not use square-cut inside corners. All inside corners should have aminimum of 1/8” (3.175mm) radius and all edges should be routed smooth.Drill oversized holes for screws or bolts. Screws or bolts should be slightly countersunk into the face side of a laminate-clad substrate.Take care to ensure an appropriate acclimation between the laminate and the substrate prior to fabrication. The face and backing laminates and the substrate should be conditioned in the same environment for 48 hours before fabrication.Recommended conditioning temperature is about 75°F (24°C). Laminates should be conditioned at 45% to 55% relative humidity.Carbide-tipped saw and router blades should be used for cutting. High tool speed and low feed speed are advisable. Cutting blades should be kept sharp. Use a hold-down to prevent any vibration.5.Warranty6.Maintenance7.Technical ServicesFor samples, literature, questions or technical assistance, please contact our toll-free Hotline at (800) 433-3222, Monday through Friday, 8 am – 5 pm, CST.Specification Form:Surface shall be Wilsonart® Traceless™, produced by Wilsonart LLC, Temple, Texas 76503-6110 Type: Specify 138SurfaceColor Number: ______________ Color Name: ______________ Edge TrimColor Number: ______________ Color Name: ______________ AdhesiveName: ______________ Grade/Type: ______________Brand: Wilsonart® AdhesiveWilsonart® Traceless™ Laminate Technical DataType 138Revised: August 6, 2020© 1998-2020, Wilsonart LLC。
WS2813英文说明书
WORLDSEMI CO.,LIMITEDWS2813Intelligent control integrated LED light source●Dual-signal wires version●Signal break-point continuous transmissionApril-2016integrated light sourceFeatures and Benefits●The control circuit and the LED share the only power source.●The control circuit and RGB chip are integrated in a5050components,to form an external control pixel.●Using the built-in signal reshaping circuit to achieve the signal waveform shaping,and no distortion of waveform ofsignal takes place.●Built-in power-on reset and brown-out reset circuits.●The gray levels of each pixel are of256levels,which achieves“256*256*256=16777216”full-color display,andthe refresh frequency reaches to2KHz/s.●Serial cascade interface,data receiving and decoding depend on just one signal line.●Dual-signal wires version,signal break-point continuous transmission.●Any two point the distance more than3m transmission signal without any increase circuit.●When the refresh rate is30fps,cascade numbers are far more than1024points.●Data transmitting at speeds of up to800Kbps.●Good color consistency reliability,high cost-effective.Applications●Guardrail tube series,point light display series,flexible/rigid strips series,module series applications.●Lighting stage costumes,innovative gadgets or any other electronic products.General descriptionWS2813is an intelligent control LED light source that the control circuit and RGB chip are integrated in a package of5050components.Its internal include intelligent digital port data latch and signal reshaping amplification drive circuit. Also include a precision internal oscillator and a12V voltage programmable constant current control part, which achieves highly consistent color effect.The data transfer protocol use single NZR communication mode.After the pixel power-on reset,the DIN port receive data from controller,the first pixel collect initial24bit data then sent to the internal data latch,the other data which reshaping by the internal signal reshaping amplification circuit sent to the next cascade pixel through the DO port.After transmission for each pixel,the signal to reduce24bit.Every pixel adopts auto-reshaping transmit technology,making the pixel cascade numbers are not limited to the signal transmission,only relate to the speed of signal transmission.The BIN receives the data signal,and then compare the data with the DIN side after phagocytosis of24bit data,if DIN do NOT receive the signal,then switching to BIN for receiving the input signal,which ensure that any the IC's damage does not affect the signal cascade transmission and make the BIN in state of receiving signal until restart after power-off. Refresh Frequency updates to2KHz,Low Frame Frequency and no Flicker appear in HD Video Camera.250us or more of reset time,it won’t cause wrong reset while interruption,it supports the lower frequency and inexpensive MCU.There’re in a choice of18mA or5mA current version,and also in a choice of high brightness or cost-effective version. That is to say,WS2813is provided with four versions.integrated light source Mechanical DimensionsRemarks1.Dimension=5.0*5.4*1.5mm2.Default tolerance=0.01mmPIN ConfigurationPIN FunctionNO.Symbol PIN Function description1NC HANGINGSuspended in PCB layout,the circuit will be out of operation when it connects to other circuits.2VDD POWER VOLTAGE Power Voltage,connect to“+5V”3DO DATA OUT Control data signal output4DIN DATA IN Control data signal input5GND GROUND Data&Power Grounding6BIN BACKUP DATA IN Backup Control data signal inputintegrated light sourceAbsolute Maximum RatingsParameter Symbol Ratings Unit Power supply voltage V DD+3.5~+5.3V Input voltage V I-0.5~VDD+0.5V Operating Temperature Topt-25~+60℃Storage Temperature Tstg-40~+120℃Electrical Characteristics(TA=-20~+70℃,VDD=4.5~5.5V,VSS=0V)Parameter Symbol Min.Tpy.Max.Unit ConditionsInput Current I I————±1µA V I=VDD/VSS High-level Input V IH0.7VDD————V D IN,SETLow-level Input V IL————0.3VDD V D IN,SETHysteresis voltage V H——0.35——V D IN,SETSwitching Characteristics(TA=-20~+70℃,VDD=4.5~5.5V,VSS=0V)Parameter Symbol Condition Min Tpy Max Unit Transmission Delay Time t PLZ CL=15pF,DIN→DOUT,RL=10KΩ————300ns Fall time t THZ CL=300pF,OUTR/OUTG/OUTB————120µs Input-capacitance C I——————15pFintegrated light sourceLED CharacteristicsWS2813A WS2813B WS2813C WS2813D Quiescent Current0.6mA0.6mA0.2mA0.2mARGB Channel Constant Current18mA18mA5mA5mA Brightness-RED(Centering)480mcd360mcd120mcd100mcd Brightness-GREEN(Centering)1500mcd1150mcd540mcd420mcd Brightness-BLUE(Centering)320mcd220mcd130mcd110mcd Brightness-WHITE(Centering)2300mcd1710mcd790mcd630mcd Wavelength-RED620-622nm620-622nm620-622nm620-622nm Wavelength-GREEN522-525nm522-525nm522-525nm522-525nm Wavelength-BLUE467-470nm467-470nm467-470nm467-470nmData Transfer Time(TH+TL=1.25µs±300ns)T0H0-code,High-level time300ns~450nsT1H1-code,High-level time750ns~1000nsT0L0-code,Low-level time300ns~100usT1L1-code,Low-level time300ns~100usRES Frame unit,Low-level time300µs or moreintegrated light source Data Transmission MethodNote:D1is the data from MCU,and D2,D3,D4are from Cascade Circuits.Composition of24bit dataR7R6R5R4R3R2R1R0G7G6G5G4G3G2G1G0B7B6B5B4B3B2B1B0 Note:Data transmit in order of GRB,high bit data is first.integrated light sourceReflow Instructions1)Lead-free Reflow:2)Leaded Reflow:integrated light sourceCurve Description Lead ReflowSolderLead-free ReflowSolder/SMTThe lowest preheat temperature(Tsmin)100℃150℃The highest preheat temperature(Tsmax)150℃200℃Preheating time(Tsmin to Tsmax)(ts)60-120S60-180S Average rate of temperature rise(Tsmax to Tp)<3℃/S<3℃/S LIQUID REGION temperature(TL)183℃217℃LIQUID REGION Holding Time(tL)60-150S60-150S Peak Temperature(Tp)215℃245℃High Temperature Region(Tp=-5℃)Holding Time(tp)<10S<10SCooling Rate<6℃/S<6℃/S Room Temperature to Peak Holding Time<6min<6min◆Remarks1.This has to be baked for48hours at the baking temperature of65-70℃before being used.e up with2hours after taking out from oven.3.Please replace the unused LEDs into oven.◆Reflow instruction1.No more than two times of reflow.2.Do not beat the colloid surface when the material is heated.◆Manual Soldering instruction1.Soldering iron’s temperature must be under300℃,and operating time must be less than3seconds.2.It should be done only once for the manual soldering.integrated light source◆Repairing instructionNormally,it can’t be repaired after reflow.You need to use double-ended solder iron and make sure that whether it will do damage to the LEDs’characteristics when repairing is inevitable.◆Storing and Transporting1.Scope of applicationFront side up,moisture-proof and waterproof,no extrusion,no collision and no vibration.2.Storage and its period1Room temperature sealed storage:20℃~30℃,40%~60%RH,product is valid for ONE month.2Moisture-proof sealed storage:20℃~30℃,25%~60%RH,product is valid for THREE month.3Use up with2hours after removing from packages.(Environmental conditions for temperature<30℃, relative humidity<60%)◆DehumidificationWe would recommend to do dehumidification if they exceed the valid storage period of products or dampened due to other reasons.Dehumidification Method:70℃-75℃/22±2Hours◆Electrostatic ProtectionLED is an electrostatic sensitive component,although the LED products are with excellent anti-static ability,they will cause a certain damage by any electrostatic discharge.By taking some electrostatic measures to avoid the damages when using the LEDs,such as wearing anti-static gloves and anti-static bracelet,etc..◆PrecautionsPressing the colloid surface will affect the reliability of LED because the LED is advanced silicone-gel.And therefore precautions should be taken to avoid the strong pressure on the component.It’s proper to make the LED be used in safe condition when using a suction nozzle.Silicon packing with soft and elastic,it greatly reduces thermal stresses and unable to bear external mechanical forces.Therefore,preventive measures should be taken in process of manually handling.integrated light source 1Clip the LED from its side.2Neither directly touch the gel surface with the hand or sharp instrument,it may damage its internal circuit.3Not to be double stacked,it may damage its internal circuit.4Can not be stored in or applied in the acidic sites of PH<7.LabelP/N:Quantity:Packing:Date:WS2813IntelligentcontrolLED integrated light source11/11 Carrier tape (Unit:mm)Reel size (Unit:mm)Moisture-proof bag。
WS2818B规格书201705
单线256级灰度三通道恒流LED驱动IC主要特点●R、G、B输出端口耐压12V,DIN端口耐压9V。
●芯片内置稳压管,12V及以下电源只需串电阻到IC VDD脚,无需外加稳压管。
●内置信号整形电路,任何一个像素点收到信号后经过波形整形再输出,保证线路波形畸变不会累加。
●内置上电复位和掉电复位电路。
●PWM控制端能够实现256级调节,扫描频率2KHz/s。
●串行级联接口,能通过一根信号线完成数据的接收与解码。
●断点续传,在单个芯片损坏的情况下,不影响整体显示效果。
●任意两点传传输距离在不超过5米时无需增加任何电路。
●光的颜色高度一致,性价比高。
●当刷新速率30帧/秒时,级联数不小于1024点。
●数据发送速度可达800Kbps。
主要应用领域●LED全彩发光字灯串,LED全彩软灯条硬灯条,LED护栏管。
●LED点光源,LED像素屏,LED异形屏。
产品概述WS2818B是三通道LED驱动控制专用电路,芯片内部包含了智能数字接口数据锁存信号整形放大驱动电路、高精度的内部振荡器和12V高压可编程定电流输出驱动器及高精度恒流控制模块,有效保证了驱动电路上像素点光的颜色高度一致。
具有独特的断点续传功能。
芯片采用双路信号传输,两路信号传输之间互不影响,在单个芯片损坏的情况下不影响整体显示效果。
用户可以选择第一个芯片的DIN脚或BIN脚作为控制器信号输入脚,其余后面级联的芯片会自动识别第一个芯片输出的信号而不影响整体效果。
数据协议采用单线归零码的通讯方式,芯片在上电复位以后,DIN端接收从控制器传输过来的数据,首先送过来的24bit数据被第一个芯片提取后,送到芯片内部的数据锁存器,剩余的数据经过内部整形处理电路整形放大后通过DO端口开始转发输出给下一个级联的像素点,每经过一个像素点的传输,信号减少24bit。
芯片采用自动整形转发技术,使得该像素点的级联个数不受信号传送的限制,仅仅受限信号传输速度要求。
当使用BIN 端作为控制器信号接收端口时,控制BIN端口的控制数据要比控制DIN端口的控制数据多24bit,这样才能保证两种方式控制的点数一致。
海华 HAWA 滑动门螺纹杆 80 2 - 80 3 - 40 4 商品说明书
18Ferrure pour le coulissement simultané de 4 portes pesant jusqu’à 40 kg ou de 2–3 portes pesant jusqu’à 80 kg par vantail.L a f e r r u r eLorsqu’elles sont utilisées en combinaison avec la technique éprouvée HAWA-Junior 80/Z et la ferrure HAWA-Telescopic 80/2 ou 80/3, il est possible de déplacer simultanément deux ou trois portes vers la gauche ou vers la droite. Le modèle équipé de la garniture HAWA- Telescopic 40/4 permet en outre l’ouverture simultanée de 2 portes coulissantes vers la gauche et vers la droite.D o n n ée s s p éc i f i q u e sH A W A -Te l e s c o p i c 80/2 – 80/3 – 40/4• poids maximum par porte 80/2, 80/3 : 80 kg • largeur de porte 80/2, 80/3 : 500–1200 mm • épaisseur de porte 80/2 : 32–47 mm • épaisseur de porte 80/3 : 40–47 mm • poids maximum par porte 40/4 : 40 kg • largeur de porte 40/4 : 500–800 mm • épaisseur de porte 40/4 : 40–47 mm• présente toutes les qualités des produits HAWA-Junior 80/Z • ouverture télescopique de 2–3 portes coulissantes • ouverture symétrique de 4 portes coulissantes • permet de grandes ouvertures• des courroies dentées renforcées par fibre de verre assurent unegrande résistance à la rupture avec une extension minimale2 vantaux: STB =(2 x P) + LMB23 vantaux: STB =(3 x P) + LMB3Sous réserve de modifications techniques.19Garniture partielle no 20657 pour HAWA-Telescopic 80/2 (2 vantaux)Garniture partielle no 20765 pour HAWA-Telescopic 80/3 (3 vantaux)Garniture partielle no 20658 pour HAWA-Telescopic 40/4 (4 vantaux)A p r éc i se r à l a c o m m a n d e• nombre et types de garnitures partielles • nombre de garnitures HAWA-Junior 80/Z •longueurs des rails de roulementP l a n i f i c a t i o n /e x éc u t i o nPour la planification et l’exécution, veuillez utiliser les instructions de montage suivantes:• HAWA-Telescopic 80/2 no 23167 • HAWA-Telescopic 80/3 no 23168 • HAWA-Telescopic 40/4 no 23169 (→ www.hawa.ch → HAWA-Productfinder)。
WS2813B控制电路与发光电路于一体的智能外控LED光源
WS2813BIntelligent control LEDintegrated light source Features and Benefits●Intelligent reverse connect protection, the power supply reverse connection does not damage the IC.●The control circuit and the LED share the only power source.●Control circuit and RGB chip are integrated in a package of 5050 components, form a complete control of pixelpoint.●Built-in signal reshaping circuit, after wave reshaping to the next driver, ensure wave-form distortion notaccumulate.●Built-in electric reset circuit and power lost reset circuit.●Each pixel of the three primary color can achieve 256 brightness display, completed 16777216 color full colordisplay, and scan frequency not less than 400Hz/s.●Cascading port transmission signal by single line.●Any two point the distance more than 5m transmission signal without any increase circuit.●When the refresh rate is 30fps, cascade number are not less than1024 points.●Send data at speeds of 800Kbps.●The color of the light were highly consistent, cost-effective..Applications●Full-color module, Full color soft lights a lamp strip.●LED decorative lighting, Indoor/outdoor LED video irregular screen.General descriptionWS2813B is a intelligent control LED light source that the control circuit and RGB chip are integrated ina package of 5050 components. It internal include intelligent digital port data latch and signal reshaping ampli fication drive circuit. Also include a precision internal oscillator and a 12V voltage programmable constant curre-nt control part, effectively ensuring the pixel point light color height consistent.The data transfer protocol use single NZR communication mode. After the pixel power-on reset, the DIN port receive data from controller, the first pixel collect initial 24bit data then sent to the internal data latch,the other data which reshaping by the internal signal reshaping amplification circuit sent to the next cascade pixel through the DO port. After transmission for each pixel,the signal to reduce 24bit. pixel adopt auto resha -ping transmit technology, making the pixel cascade number is not limited the signal transmission, only depend on the speed of signal transmission.LED with low driving voltage, environmental protection and energy saving, high brightness, scattering angle is large, good consistency, low power, long life and other advantages. The control chip integrated in LED above becoming more simple circuit, small volume, convenient installation.WS2813BIntelligent control LEDintegrated light sourceMechanical DimensionsPIN configurationPIN functionNO.Symbol Function description1 VDD Power supply LED2 DOUT Control data signal output3 VSS Ground4 DIN Control data signal inputAbsolute Maximum RatingsPrameter Symbol Ratings UnitPower supply voltage V DD+3.5~+5.3 VInput voltage V I-0.5~VDD+0.5 VOperation junctionTopt -25~+80 ℃temperatureWS2813BIntelligent control LEDintegrated light source Storage temperature range Tstg -55~+150 ℃Electrical Characteristics(T A=-20~+70℃,V DD=4.5~5.5V,V SS=0V,unless otherwise specified)Prameter Smybol conditions Min Tpy Max UnitInput current I I V I=V DD/V SS————±1 µAInput voltage level V IH D IN,SET 0.7V DD————V V IL D IN,SET ————0.3 V DD VHysteresis voltage V H D IN,SET ——0.35 ——V Switching characteristics(T A=-20~+70℃,V DD=4.5~5.5V,V SS=0V,unless otherwise specified)Prameter Symbol Condition Min Tpy Max Unit Operation frequency Fosc2 ————800 ——KHzTransmission delaytime t PLZCL=15pF,DIN→DOUT,RL=10KΩ————300 nsFall time t THZ CL=300pF,OUTR/OUTG/OUTB————120 µsData transmissionrateF MAX Duty ratio50% 400 ————Kbps Input capcity C I——————15 pFWS2813BIntelligent control LEDintegrated light sourceLED characteristic parameterEmitting colorModel Wavelength(nm)Luminous intensity(mcd)V oltage(V) Red 13CBAUP 620-625 390-420 2.0-2.2 Green 13CGAUP 522-525 660-720 3.0-3.4 Blue10R1MUX465-467180-2003.0-3.4Data transfer time( TH+TL =1.25µs ±600n s )T0H 0 code ,high voltage time 0.4us ±150ns T1H 1 code ,high voltage time 0.8us ±150ns T0L 0 code , low voltage time 0.85us ±150ns T1L 1 code ,low voltage time0.45us ±150ns RESlow voltage timeAbove 50µsSequence chart:0code1codeRET codeT0HT0LT1H T1LTresetCascade method:DIN DIN DIN DODODOPIX1D1D2D3D4PIX2PIX3WS2813BIntelligent control LEDintegrated light sourceData transmission method :Note: The data of D1 is send by MCU,and D2, D3, D4 through pixel internal reshaping amplification to transmit.Composition of 24bit data:G7G6 G5 G4G3 G2G1 G0R7R6R5R4R3R2R1R0B7B6B5B4B3B2B1B0Note: Follow the order of GRB to sent data and the high bit sent at first.Data refresh cycle 1Data refresh cycle 2first 24bitsecond24bit third 24bitfirst 24bitsecond 24bitthird 24bitsecond 24bitthird 24bitsecond 24bitthird 24bitthird 24bit third 24bitD1D2D3D4reset code >=50usreset codeIntelligent control LEDintegrated light sourceTypical application circuit:WS2813BIntelligent control LEDintegrated light source21DCV1 D2U WV1 D2U WC1 104C2 1045V 5V。
28130;中文规格书,Datasheet资料
METALIZATION DIAGRAM
TEMPERATURE SCALE CONVERSION EQUATIONS
+2.0 +1.5 +1.0 +0.5
0 –0.5 –1.0 –1.5 –2.0
–25
0
+25
+70
TEMPERATURE – oC
+105
AD592BN Accuracy Over Temperature
TOTAL ERROR – oC TOTAL ERROR – oC
+2.0 +1.5 +1.0 +0.5
+1.0
+0.5
MAXIMUM ERROR OVER TEMPERATURE
TYPICAL ERROR
0 CALIBRATION ERROR LIMIT
–0.5
TOTAL ERROR – oC
IOUT – µA
378
+105oC
298
+25oC
–25oC 248
UP TO 30V
0
1
2
3
4
5
6
SUPPLY VOLTAGE – Volts
66MILS
V+
V–
/
Model
AD592CN AD592BN AD592AN
42MILS
؇C = 5 (؇F –32) 9
WS2813规格书
主要特点●所有元件集成在5050封装中,不需要任何其他外围元件构成一个完整的外控像素点。
●智能反接保护,5V电源接反时不会损坏元器件。
●内置信号整形电路,任何一个像素点收到信号后经过波形整形再输出,保证线路波形畸变不会累加。
●每个像素点的三基色颜色可实现256级亮度显示,完成16777216种颜色的全真色彩显示●端口扫描频率2KHz/s。
●串行级联接口,能通过一根信号线完成数据的接收与解码。
●断点续传,额外增加一路信号线,实现双路信号传输,在单个像素点损坏的情况下,不影响整体显示效果●任意两点传传输距离在不超过5米时无需增加任何电路。
●当刷新速率30帧/秒时,级联数不小于1024点。
●数据发送速度可达800Kbps。
●光的颜色高度一致,性价比高。
主要应用领域●LED全彩发光字灯串,LED全彩软灯条硬灯条,LED护栏管。
●LED点光源,LED像素屏,LED异形屏。
产品概述WS2813是一个集控制电路与发光电路于一体的智能外控LED光源。
其外型与一个5050LED灯珠相同,每个元件即为一个像素点。
像素点内部包含了智能数字接口数据锁存信号整形放大驱动电路,防反接电路,还包含有高精度的内部振荡器和高精度恒流控制模块,有效保证了像素点光的颜色高度一致。
具有独特的断点续传功能,实现双路信号传输,在单个像素点损坏的情况下,不影响整体色彩的显示。
数据协议采用单线归零码的通讯方式,像素点在上电复位以后,DIN端接受从控制器传输过来的数据,首先送过来的24bit数据被第一个像素点提取后,送到像素点内部的数据锁存器,剩余的数据经过内部整形处理电路整形放大后通过DO端口开始转发输出给下一个级联的像素点,每经过一个像素点的传输,信号减少24bit。
像素点采用自动整形转发技术,使得该像素点的级联个数不受信号传送的限制,仅仅受限信号传输速度要求。
BIN端接收到数据信号吞噬24bit数据后,和DIN端数据比较,若DIN端无信号,BIN端有接收到信号,切换到BIN端接收输入信号,确保其中一个IC的损坏不会影响信号的级联传输,控制IC保持在BIN端口接收状态,直到断电后的下次开机重新确认。
WS2801技术规格书
单位 V V V V mA
% MHz mW ℃/W
℃
V
最大 5.5 28 6 120 200 1 --1.5 --
±1
单位 V V V mA mA uA mA mA mA uS
uA
±20
uA
VDD
V
0.2*VDD V
0.624
V
0.2
V
--
%/V
--
%/V
--
KΩ
2
内部功能框图
DS-2801-SC rev0.1
3
典型应用电路
DS-2801-SC rev0.1
crossLED series
图3, WS2801 DC12V恒流典型应用电路
应用手册:
图4, WS2801 DC5V恒压典型应用电路
4
DS-2801-SC rev0.1
crossLED series
电压大于5V时候的应用: WS2801 的工作电源电压范围为 3.3~5.5V,芯片内部集成了 5.5V 稳压器以满足在高输入电压下芯片能够可靠工作。只需要在电
LED灰度控制信号在芯片内部经过时钟数据再生电路整形后在CKO和SDO端输出,以使芯片能够接力串接工作。当POL=
“0”时,输出极性反转,WS2801工作如同一个PWM控制器,能够驱动外接的开关或者电路驱动高亮度的LED,并实
现大功率LED的256级灰度控制。WS2801的2-线传输控制协议具有速度快,可靠性高,灰度数据同步刷新等特点,能够
I LED
其中RL是电流设定电阻,VDD是LED串的电源,VLED是LED串工作时的正向导通压降,VOUT是驱动输出的饱和压降,大概在0.1~0.2V, ILED是LED工作的工作电流,通常ILED≤20mA.
XX船洗衣机、挂烫机规格书
XX型**舰洗衣机、挂烫机技术规格书上海华比工贸发展有限公司二○一二年三月XX型 ** 舰洗衣机、挂烫机技术规格书签署沪东中华造船(集团)有限公司代表:年月日上海华比工贸发展有限公司:年月日驻沪东中华造船(集团)有限公司军事代表室代表:年月日1.1主题内容本规格书规定了XX型**舰洗衣机、挂烫机的组成、接口、主要功能、主要性能、物理特性、环境条件、可靠性、维修性、保障性、安全性、随机文件、人员和培训、质量保证和交货准备等内容。
1.2适用范围本规格书适用于XX型**舰,是洗衣机/挂烫机的设计、制造、试验验收和交付的依据,并作为订货合同的附件。
2.引用文件本规格书引用的有关标准、规范和法规如下:例如(根据各设备情况自定):GB191-1990 包装储运图示标志GJB900-1990 系统安全性通用大纲GJB1060.1-1991 舰船环境条件要求机械环境GJB1406A-2005 产品质量保证大纲要求GJB4000-2000 舰船通用规范GJB9001A-2001 质量管理体系要求《舰船设备包装、装卸、运输、贮存、安装防护规定》《中华人民共和国法定计量单位》1984年2月国务院发布海装〔2002〕装舰字第13号《新造舰艇舰员在厂技术培训暂行规定》海装〔2004〕装舰字第56号《舰艇完工文件数字化编制格式要求》海装〔2004〕装舰字第105号《新造舰艇舰员在厂培训技术教材编制《舰船防腐防漏系列技术要求》要求3.1概述3.1.1组成表1表23.1.2接口3.1.2.1电源接口:单相交流220V(-10%--+6%),50 Hz(±5%)。
3.1.2.2设备在送认可资料中明确标出上下水接头位置,管径、电缆接线位置,电源接线方法,外形尺寸和底座尺寸,安装维修空间。
3.1.2.3所有设备应适合船上使用,并提供设备安装尺寸和要求。
3.1.2.4设备与船体连接及接地装置的可靠性,接地电阻不应大于10mΩ。
调速器 ESK2813_e(2012年10月22号标注)
Table of contents : =ALLG+DOKU/1 =AW+STK/1.f
625-00-025-01
= ALLG + DOKU
General Documentation
Modification
Date
Name
ESK2813
Page Pg
625-00-025-01
= ALLG + DOKU
General Documentation
01
Modification
Date
Name
ESK2813
Page Pg
2 39
0
1
2
3
4
5
6
7
8
9
Cable data
Cross Section Requirements, if not specified: 1. DGM: 2. DC: 3. Supply: Cable Size for HELENOS and PANDAROS: Positioner (Motor Cable): 1. Cable to 10m 2. Cabel over 10m to 20m 3. Cable over 20m to 40m Supply: 1. Cable to 15m 2. Cable over 15m to 30m 3. others Cable types for Communication Cable: CAN: 1. HELU CAN-Bus 1x2x0,22 shielded 2. BELDEN CAN Modbus 2-wire: 1. BELDEN 2. BELDEN 3. BELDEN Modbus 4-wire: 1. BELDEN 2. BELDEN
海天马3寸三体球阀说明书
HAITIMAInstruction Manual3-PCS Ball Valve2012CDA/2013CDA HIM-131 Version: COffice : 8F, No.201, Tiding Blvd. Sec.2, Taipei, 114, Taiwan Web-site: Fax: +886-2-2658-3830 , 2658-2266 Tel:+886-2-2658-5800 E-mail: ****************.twV Z B D -_-S 5_W 3-16-T -2-_ | 8147476 2020-10bDateNov.02,2018Document No. HIM-131CONTENTS1. Introduction and Safety Information (1)1.1 Introduction .......................................................................................................................................................................... 1 1.2 Safety Information ................................................................................................................................................................ 1 2. General Precautions (2)2.1 Material Selection ................................................................................................................................................................. 2 2.2 Pressure-T emperature Rating ............................................................................................................................................... 2 2.3 Fluid Thermal Expansion ....................................................................................................................................................... 2 2.4 Hydrostatic Test .................................................................................................................................................................... 2 2.5 Liquids with High Fluid Velocity ............................................................................................................................................ 3 2.6 Throttling Service .................................................................................................................................................................. 3 2.7 Direct Mounting Pad ............................................................................................................................................................. 3 3. Storage and Preparation .. (4)3.1 Storage .................................................................................................................................................................................. 4 3.2 Preparation ........................................................................................................................................................................... 4 4. Operation . (5)4.1 Operation .............................................................................................................................................................................. 5 4.2 Manual Operation ................................................................................................................................................................. 5 5. Maintenance and Repair .. (6)5.1 Inspection and Maintenance ................................................................................................................................................ 6 5.2 Trouble-Shooting .................................................................................................................................................................. 7 5.3 Stem Packing Replacement (8)V Z B D -_-S 5_W 3-16-T -2-_ | 81DateNov.02,2018Document No. HIM-1316. Quality Assurance and Service (9)6.1 Quality Assurance ................................................................................................................................................................. 9 6.2 Service ................................................................................................................................................................................... 9 7. Technical Parameters and Valve Structure .. (10)7.1 Specification List ................................................................................................................................................................. 10 7.2 Bolts Torque ........................................................................................................................................................................ 10 7.3 Pressure-Temperature Ratings ........................................................................................................................................... 11 7.4 Repair Parts List .................................................................................................................................................................. 11 7.5 Installation of Actuator ....................................................................................................................................................... 12 7.6 Valve Structure .. (12)V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page11. 1.1 INTRODUCTIONThis manual has been prepared to serve as a guide to insure continuous satisfactory service and assist in restoring a valve to proper working condition.It is 3 pieces 1000WOG with ISO 5211 direct mounting pad, tube ends, clamp ends, and stainless steel ball valves.The installation, storage, operation, inspection and repair, service problems, maintenance and preventive maintenance, quality assurance and service, technical parameters covering these valves are also included in this manual. All these valves are widely used in water system, petroleum, chemical, power plant and allied industries.1.2 SAFETY INFORMATIONThe following general safety notices supplement the specific warnings and cautions appearing elsewhere in this manual. They are recommended precautions that must be understood and applied during operation and maintenance of the equipment covered herein.a. Always wear eye shields, gloves and overalls. Wear protective footwear and headgear.b. To avoid injury, never attempt disassembly while there are pressures either upstream, or downstream. Even when replacing packing rings, caution is necessary to avoid possible injury.c. Do not attempt to disassemble a valve while there is pressure in the line. Make sure both upstream and downstream pressures are removed. Disassemble with caution in the event all pressures have not been relieved. d. Prior to replacing packing rings remove all pressure from the valve.e. To prevent valve distortion, inefficient operation, or early maintenance problems, support piping on each side of the valve.f. Do not touch surface of valve on high temperature.g. Valves are not to be used with unstable fluids.h. If provided, the Locking device on the handle is to avoid improper use of the valve by unauthorized people. This can be locked with a patch lock.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page22. 2.1 MATERIAL SELECTIONThe possibility of material deterioration in service and the need for periodic inspections is depended on the contained fluid. Carbide phase conversion to graphite, oxidation of ferrite materials, and decrease in ductility of carbon steels at low temperature (even in applications above 29°F) and susceptibility to inter-granular corrosion of austenitic materials or grain boundary attack of nickel-base alloys are among those items. Information about corrosion data is provided in this I.O.M, the user is requested to take attention or consideration to determine if the used materials are suitable for the application.2.2 PRESSURE-TEMPERATURE RATINGThe Pressure-T emperature rating, published by manufacturer is usually considered an appropriate guide to the maximum temperature and pressure those ball valves may withstand. The principle of pressure-temperature rating is depending on static pressure. For reference client can ask the valve distributor or manufacturer for assurance of suitability when ball valves are subjected to the following conditions:- Valves are left closed for long periods of service under high-temperature or high-pressure service conditions - Valves are operated frequently for long periods with high-temperature or high-pressure service conditions.2.3 FLUID THERMAL EXPANSIONIt is possible, with the ball in closed condition; the sealed cavity inside the valve body is filled with liquid. If this liquid is not released, by partially opening the valve, and the valve is subject to a temperature increase, excessive pressure can occur inside the body. These HAITIMA ball valves have self-relieving pressure seats to prevent pressure built up. Our client is recommended to prevent a pressure build-up inside the valve exceeding the design pressure, by means of piping design, installation, or operation procedure.2.4 HYDROSTATIC TESTBefore delivery, all valve body’s are tested 1.5 times the working pressure in open position. After installation, the pipeline system may be subject to a system test not to exceed the above mention pressure.(For example: 1000 WOG is hydrostatic tested 1.5 X 1000 = 1500 psi testing pressure)V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page32.5 LIQUIDS WITH HIGH FLUID VELOCITYWhen ball valves must be operated frequently on liquids with very high velocity, a check shall be made with the valve distributor or manufacturer for appropriate advice to minimize the possibility of seat deformation, especially when working pressure and temperature is reaching maximum ranges.2.6 THROTTLING SERVICEStandard ball valves are generally not recommended for throttling service. The fluid flow can damage the leading edge of the ball and/or damage or deform the resilient ball seats causing leakage. High fluid velocity and/or the presence of solid particles in the media will reduce the lifetime of seat and ball during throttling applications.2.7 DIRECT MOUNTING PADISO 5211 direct mounting pad and stem orientation allows direct mounting for actuator to valves, no brackets and couplers are required, making automation a lot easier with improved performance.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page43. 3.1 STORAGE3.1.1 Temporary StorageIf valves are to be stored before installation, the following should be observed.a. Keep the valves wrapped and protected as shipped from the manufacturer.b. Do not remove the plastic bag or protective end covering until the valve is ready for installation. This will reduce the possibility of foreign material damaging internal valve components.c. Valves stored outdoors should be positioned such that water dose not accumulate in the valve body.3.1.2 Long Term StorageIf the valves are to be stored more than of one year, they should be prepared in the following manner.a. Remove the packing and apply a preservative to the packing chamber.b. Do not remove the protective end covering.c. Valve which will remain in storage for an excessive period of time should have a preservative applied to the external surface.d. Do not store the valves outdoors.3.2 PREPARATIONa. Remove the plastic bag or valve end protection (if any).b. Prior to shipment from the manufacturer, a preservative may have been applied to the inner body of the valve. This preservative maybe removed with a solvent.c. The inside of the valve should be inspected and blown out with compressed air. Adjacent piping must be clean and free from debris to prevent damage to the valve.d. To prevent valve distortion, inefficient operation or early maintenance problems, support piping on each side of the valve.e. Make sure the valve is positioned such that there is sufficient space so that the handle is easily and safely reached.f. The 3 piece ball valves can be installed in any position without regard for the direction of the flow, unless marked in the flow direction.g. The 3 piece ball valves are not designed for throttling and should be kept in the fully open or closed position. Should the valve be used in a partially open or closed position, the ball and seats may become eroded in a very short time. This may also cause a chatter noise in the line.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page54.1 OPERATIONHAITIMA valves provide tight shut off when used under normal conditions and in accordance with pressure/temperature chart. If these valves are used in partially open (throttled) position seat life may be reduced. Any media which might solidify, crystallize or polymerize should not be allowed to stand in the ball valve cavities unless regular maintenance is provided.4.2 MANUAL OPERATIONThe basic type of handle which is fitted to all sizes of valve is sheet steel with integral stop. The 3 pieces ball valves have 1/4 turn operation closing in a counter-clockwise direction. It is possible to see when the valve is open or closed by the position of the handle. When the handle is across the pipeline, the valve is closed.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page65.1 INSPECTION AND MAINTENANCEA periodic inspection and maintenance schedule should be established for each valve. The time frames given for theimplementation of these schedules are to be used as a guide only in establishing routine inspection and maintenance schedules. Exact time periods for performing these procedures cannot be provided due to the unknown nature of the service conditions each valve is in. 5.1.1 Periodic InspectionA periodic inspection should be performed on each unit. The time frame should be adjusted depending on usage and service conditions. An infrequently used unit may have more time between inspections than a valve in constant service. A periodic inspection should include the following:a. Open and close the valve. The actions should be smooth without any binding of the stem and ball through full travel.b. If valve is in service and under pressure:(1) Examine the body to caps connection for leakage through the gasket. If leakage is found, tighten the bolt nuts evenly in a star pattern until the leakage slops. Do not exceed the maximum torque values in Table 3. If the leakage persists, see section 5.2(2) Check the stem packing for any leakage during the opening and closing action. If a leak is found tighten the gland nut alternately with no more than a quarter turn on it until the leak stop. If the leakage persists, see section 5.2 (3) Inspect the exterior of the valves for cleanliness. Remove any dirt, grime or oil from the valve body and caps.5.1.2 Post InspectionAfter completion of a periodic inspection, valves that are providing satisfactory service require no further disassembly or inspection. Should a valve be found which is not performing satisfactorily, see section 5.2 "Trouble-Shooting". 5.1.3 MaintenanceOther than periodic inspection, no routine maintenance is required. Routine replacement of parts, such as gasket and packing is not usually performed until required. Once in service, it may become apparent that these and other parts require repair or replacement due to usage and service conditions. A maintenance schedule should be developed taking these conditions into consideration. Parts can be replaced during a routine overhaul.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page75.2 TROUBLE-SHOOTINGThe following chart will cover the various problems which are common to most valves. The information provided will aid in isolating and correcting these problems.PROBLEMPROBABLE CAUSESOLUTIONLeakage through the Stem and packinga. Gland nut looseb. Packing aged or failurec. Inadequate amount of packing ringsd. Packing is hard and drye. Thrust washer is damagedf. Stem is damageda. Tighten gland nutb. Replace packingc. Install additional packing rings See section 5.3d. Replace with new packing See section 5.3e. Replace with new thrust washerf. Repair or replace as requiredProblems in operating valveg. Gland nut over wearh. Packing is exerting excessive force on the stem i. Stem is damagedj. Internal components may be damagedg. Replace gland nuth. Check torque on gland nuts. Proper loose gland nut.i. Repair or replace as requiredj. Disassemble the valve. Inspect ball, seat, stem and repair as needed Leakage between body and capk. Bolt nuts are loose l. Gasket is damagedm. Body or cap faces are damaged k. Tighten to values listed in Table 3 i. Disassemble and install a new gasket m. Repair and install a new gasket Seat Leakagen. Valve not properly seatedo. Internal components (ball, seat, stem) are damaged or worn p. Leakage by foreign materialn. Check to see if valve is fully closed o. Inspect internal components (ball, seat, and stem) and repair or replace as requiredp. Disassemble and clean the ball and seats and repair or replace as requiredThe flow bore is not in alignmentq. Tolerancer. The valve does not open or closecompletelys. The space between stem and handle istoo largeq. The ball and flow bore deviating +/-1degree is within normal tolerance ranger. Check to see if the valve is fully open orcloses. Replace the new handleTable 1 - Valve Trouble-ShootingV Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page85.3 STEM PACKING REPLACEMENTWARNINGTo prevent injury ensure that all pressure is removed from the valve both upstream and downstream before disassembly.a. Check original tightness of valve operation. Remove stem nut, washer, handle, and gland nut. Clear the packingchamber.b. Remove the existing or defective packing rings with a sharp tool or packing remover.c. Examine the machined surfaces of the stem and packing chamber. Remove any scoriae or burrs with emery cloth orhand filing. Clean the stem with a solvent soaked rag.d. Install new packing. Install rings individually using a split ring spacer, compressing each ring by hand tightening thegland nut.e. When packing chamber becomes filled with packing, reassemble gland nut. Tightening the gland nut until gland nutbegin to get tight. (Tighten gland nut torque value show in table 3.)f. Compare valve operation to original tightness. If valve operation is considerably tighter than original operatingtightness, back off 1/4 turn on the gland nut and recheck tightness.g. Several hours after a repacked valve has been returned to service, inspect the packing area to ensure fullcompression, tight bolting and no leakage. Should leakage occur, tighten the gland nut at 1/4 turn increments until leakage stops.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page96.1 QUALITY ASSURANCEHAITIMA’s warrants its products to be free from defects in material and workmanship for a period of eighteen (18) months from the date of shipment or twelve (12) months from the date of installation whichever comes first. This warranty is limited to the repair or replacement of the defective item providing that it was handled, installed, used and maintained in accordance with the manufacturer’s recommendations and applicable standard industry practices. HAITIMA will not be liable for any additional direct or indirect costs beyond the repair or replacement of the defective item. This warranty is in lieu of any other warranty expressed or implied.6.2 SERVICEManufacturer may provide field installation and debugging where contractually specified.Manufacturer will follow up the quality of the valve provided and offer service in accordance with customer requirements.V Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page107. 7.1 SPECIFICATION LISTTable 2 - Specification List7.2 STEM NUT & BOLTS TORQUENPS DN Stem nut Bolt N-m in-lb Size N-m in-lb 1/2" 15 13 115 M8 17 151 3/4" 20 13 115 M8 17 151 1" 25 20 177 M8 17 151 1-1/4" 32 20 177 M10 23 204 1-1/2" 40 30 266 M10 23 204 2" 50 30 266 M12 28 248 2-1/2"6560531M1433292Table 3 - Stem Nut & Bolts TorqueV Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page117.3 PRESSURE-TEMPERATURE RATINGSTable 4 - Pressure-Temperature Ratings7.4 REPAIR PARTS LISTTable 5 - Repair Parts ListParts Quantity Ball1 piece Seat & Seal (Gasket) 1 Set (2piece) Thrust Washer 1 piece Packing 1 Set (2piece) O-Ring1 pieceV Z B D -_-S 5_W 3-16-T -2-_ | 812012CDA/2013CDADate Nov.02,2018Document No. HIM-131Page127.5 INSTALLATION OF ACTUATORThe ball valves are provided with ISO 5211 direct mounting pad. Following top flange sizes are used;Size ISO 5211 1/2” ~ 3/4” F03 / F04 1” ~ 1-1/4” F04 / F05 1-1/2” ~ 2” F05 / F07 2-1/2”F07 / F10Sizing of actuators and the power or air pressure needed for the actuator is depending on the operation torque and working pressure of the valve. The above table lists the size of ISO top flange per valves. Client is recommended to refer to the instructions of the actuator supplier. If actuators torque value choice too big can result in damaging the inner parts and spindle of the ball valve.An Actuator should not exceed a torque greater as 1.5 times of the max operation torque data.7.6 VALVE STRUCTUREPlease refer to drawings for each type of valve structure, main parts, materials and dimensions.V Z B D -_-S 5_W 3-16-T -2-_ | 81。
SODICK - 备件目录说明书
Slovakia SODICKSODICK–náhradné diely Dodávame aj ďalšie náhradné diely, ktoré nie sú uvedené v tejto kapitole.V prípade, že nenájdete požadovaný náhradný diel, nás neváhajte kontaktovať.Conductivity piece D (UT) 12.5 x 14 x 11.7 mm / Cermit Power feed contact upper and lower10x10x20Conductivity piece P-AWT / U-shape(upper & lower)OD10 / 8 x 30 mm / Silver tungstenConductivity piece P-AWT / U-shape(upper & lower)OD10 / 8 x 30 mm / Cermit 3085936 Conductivity piece 87-3 (upper & lower)4.8 x 40 x 20 mmTungsten Carbide 3085936 Conductivity piece 87-3 (upper & lower)4.8 x 40 x 20 mmPure TungstenPower feed contact lower4.9 x 10 x 40 mmDiamond guide upperSlide typeSapphire; split guide AWT Diamond dies guideManual type Upper & lowerDiamond long guide 87-3L typeØ3mmAWT taper upper onlyOD7.5/5.0 x 6.0 mmTAWT Die A Upper & LowerManual Upper / LowerAF - LowerSapphireDiamond guide high longtypeUpper & lowerManual typeGuide sapphire C for AWT OD=10.0 x id=0.80 mm x 10 mmLManual type (for upper guide parts) Sub guide C1 for AWTOD=10.0 x id=2.0 mm T=10 mm for AWF (for lower guide parts)Sub guide C1 for AWTOD=10.0 x id=0.75 mm T=10 mm for AWTJet AWT Nozzle DUpper1,2Jet AWT Nozzle NSUpper1,5Jet Nozzle NS Upper(Plastic)Dies block for S102 dies guideWater nozzle NE guide / Upper & lower D=5 mm for SUS assy84 typeRectification nozzles 3WSUpper and lower Nozzle PUpper & lowerWater nozzle upper & lower iD=10 mm Guide unit type KM-1Nozzle C upper / Standard D=6 mm Nozzle H2 upper / Standard D=10 mm Nozzle T2 for taper 30Nozzle T2 for taper 30° D=16 mm Nozzle G3 upper Without AWT D=3 mm Nozzle G4 upper Without AWT D=4 mmWater nozzle lowerNozzle A D=6 mmNozzle H1 D=10 mmNozzle B D=8 mmNozzle T1 for taper 30Nozzle E2 D=2 mmNozzle E4 D=4 mmNozzle LA S209 id=6.0mm Nozzle LA10 S209 id=6.0mm Nozzle LA15 S209 id=6.0mm Nozzle LA20 S209 id=6.0mm Nozzle LA25 S209 id=6.0mm Nozzle LA50 S209 id=6.0mm Float nozzle S /Lower without O-ring AWT Float nozzle T /Lower without O-ring AWT Float nozzle F /Lower without O-ring AWT Float nozzle Slower standard without O-ring Float nozzle Flower without O-ringFloat nozzle Tlower without O-ringFloat nozzle Slower without O-ringWater Nozzle LowerWater Nozzle LowerWater Nozzle LowerLong typePulley "E" for wire evacuationbeltSUS type / AS-5543Shaft for pulley ´´E´´Pulley "E" assembly for beltCeramic flat type without groove OD=25 mmCeramic pulley only for S400C/FFlat type without grooveOD=25 mmSS626LLB Bearing for pulley S400Roller upper for wire beltRoller assembly upper for wire beltNozzle guide lower for S209W38 x 38 mmSpring ring lower for float nozzleNozzle guide lower Nozzle guide lower 6 holesSUS feed roller "B" OD70 x id12 mmRoller BFeed SectionCeramic + gearRoller LEject SectionCeramicRoller CFeed sectionCeramic + gearRoller UEject sectionWire guide blockRollerDies driveOD= 22mmSpring Ring FJ LowerFJ-AWT for S209FJ Nozzle Base FJ LowerFJ-AWTCutter upper for AWTCutter springOD10.5 mmCutterCutterBrushPulley-B Unit UpperMW402811NFelt AWire feed UnitMW409946AFelt BWire feed UnitMW409947ALower electrodeCylinder-shapedMT500196DLower Electrode 20x20x14mm MT502325BIntermediate electrodeMT500177CAWT pipe upper OD=2.0 x id1.0 mm L=275 mmAWT pipe upper OD=2.0 x id0.7 mm L=275 mmAWT pipe upper OD=2.0 x id1.4 mm L=285 mmAWT pipe upper OD=2.0 x id1.0 mm L=285 mmAWT pipe upper OD=2.0 x id0.7 mm L=285 mmAWT pipe upper OD=2.0 x id0.5 mm L=285 mmAWT Pipe 3,0-2,0FJ AWTAWT Pipe 3,5-3,1FJ AWTSpring for AWT slide beltDischarge cable L=450mm Discharge cable L=750mm Discharge cable L=500mm Discharge cable L=650mm Discharge cable L=850mm Discharge cable L=950mm Discharge cable L=1050mmFlow MeterAspirator nozzle A / Plastic material OD16 x id1.0 x 25 mmAspirator nozzle B / Plastic materialOD16 x id2.0 x 40 mmAspirator nozzle C / Plastic materialOD12 x id1.5 x 26.5 mmCeramic pulley E-set assembly OD=32 mmCeramic pulley ´´E´´ assembly with grooveOD=40 x id19 x 24mm Ceramic pulley ´´E´´with groove 2.0mmOD=40 x id19 x 24mm Feed roller ´´B´´OD50 x 24mmTRoller shaft for feed roller ´´B´´OD15 x 173 mmLRoller shaft for feed roller ´´B´´OD15 x 163 mmLPin connectorOD16 x id10 x 27mmPin connectorOD16 x id10 x 50mmBellows Z upper440 x 30 mmClamp shaft for plate S5091.S5092Suction blockBevel gearOD32 x id10mm T=17mm Shaft for roller ´´B´´OD18 x 122 mm18 x 465 mm。
din28138-3_2006-06d
ห้องสมุดไป่ตู้
-XQL
',1
,&6
(UVDW] IU ',1
*OHLWULQJGLFKWXQJHQ IU 5KUZHOOHQ ± 7HLO $QVFKOVVH IU 6SHUUIOVVLJNHLWHQ .KOXQJ .RQWUROOH XQG 0RQWDJH XQG %H]HLFKQXQJVV\VWHP IU *OHLWULQJGLFKWXQJHQ
2
Normative Verweisungen
Die folgenden zitierten Dokumente sind für die Anwendung dieses Dokuments erforderlich. Bei datierten Verweisungen gilt nur die in Bezug genommene Ausgabe. Bei undatierten Verweisungen gilt die letzte Ausgabe des in Bezug genommenen Dokuments (einschließlich aller Änderungen). DIN 3404, Flachschmiernippel
2
DIN 28138-3:2006-06
Vorwort
Dieses Dokument wurde vom Unterausschuss NA 012-00-01-02 UA „Anbauteile“ des Normenausschusses Chemischer Apparatebau (FNCA) erarbeitet. DIN 28138 Gleitringdichtungen für Rührwellen besteht aus: Teil 1: Aus unlegiertem oder nichtrostendem Stahl — Betriebsdaten, Einbaumaße Teil 2: Aus Stahl, emailliert — Betriebsdaten, Einbaumaße Teil 3: Anschlüsse für Sperrflüssigkeiten, Kühlung, Kontrolle und Montage und Bezeichnungssystem für Gleitringdichtungen Änderungen Gegenüber DIN 28138-3:1983-10 wurden folgende Änderungen vorgenommen: a) b) c) d) Titel der Norm geändert; Terminologie an die Druckgeräterichtlinie angepasst; Ausführung mit Losflansch gestrichen; redaktionelle Änderungen vorgenommen.
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
主要特点●所有元件集成在5050封装中,不需要任何其他外围元件构成一个完整的外控像素点。
●智能反接保护,5V电源接反时不会损坏元器件。
●内置信号整形电路,任何一个像素点收到信号后经过波形整形再输出,保证线路波形畸变不会累加。
●每个像素点的三基色颜色可实现256级亮度显示,完成16777216种颜色的全真色彩显示●端口扫描频率2KHz/s。
●串行级联接口,能通过一根信号线完成数据的接收与解码。
●断点续传,额外增加一路信号线,实现双路信号传输,在单个像素点损坏的情况下,不影响整体显示效果●任意两点传传输距离在不超过5米时无需增加任何电路。
●当刷新速率30帧/秒时,级联数不小于1024点。
●数据发送速度可达800Kbps。
●光的颜色高度一致,性价比高。
主要应用领域●LED全彩发光字灯串,LED全彩软灯条硬灯条,LED护栏管。
●LED点光源,LED像素屏,LED异形屏。
产品概述WS2813是一个集控制电路与发光电路于一体的智能外控LED光源。
其外型与一个5050LED灯珠相同,每个元件即为一个像素点。
像素点内部包含了智能数字接口数据锁存信号整形放大驱动电路,防反接电路,还包含有高精度的内部振荡器和高精度恒流控制模块,有效保证了像素点光的颜色高度一致。
具有独特的断点续传功能,实现双路信号传输,在单个像素点损坏的情况下,不影响整体色彩的显示。
数据协议采用单线归零码的通讯方式,像素点在上电复位以后,DIN端接受从控制器传输过来的数据,首先送过来的24bit数据被第一个像素点提取后,送到像素点内部的数据锁存器,剩余的数据经过内部整形处理电路整形放大后通过DO端口开始转发输出给下一个级联的像素点,每经过一个像素点的传输,信号减少24bit。
像素点采用自动整形转发技术,使得该像素点的级联个数不受信号传送的限制,仅仅受限信号传输速度要求。
BIN端接收到数据信号吞噬24bit数据后,和DIN端数据比较,若DIN端无信号,BIN端有接收到信号,切换到BIN端接收输入信号,确保其中一个IC的损坏不会影响信号的级联传输,控制IC保持在BIN端口接收状态,直到断电后的下次开机重新确认。
高达 2KHZ的端口扫描频率,在高清摄像头的扑捉下都不会出现闪烁现象,非常适合高速移动产品的使用。
250us以上的 RESET时间,出现中断也不会引起误复位,可以支持更低频率,价格便宜的MCU.WS2813提供 15mA和 5mA两种电流版本,每种版本分别提供高亮度的版本和高性价比版本,一共4个规格。
机械尺寸(单位mm)引脚功能 :序号符号管脚名功 能 描 述1 NC 空脚 PCB LAYOUT 时悬空处理,连接到其他线路会引起电路工作异常2 VDD 电源 LED 芯片供电脚,接 +5V 电源3 DO 主数据输出 控制数据信号输出脚4 DIN 主数据输入控制数据信号输入脚 5 GND 地线 信号接地和电源接地脚 6BIN辅数据输入辅助数据信号输入脚最大额定值(如无特殊说明,T A =25℃,V SS =0V )参数符号范围单位电源电压 V DD +3.0~+5.3 V 逻辑输入电压 V I -0.5~VDD+0.5 V 工作温度 Topt -25~+60 ℃ 储存温度Tstg-40~+120℃电气参数(如无特殊说明,T A =-20~+70℃,V DD =4.5~5.5V,V SS =0V )开关特性(如无特殊说明,T A =-20~+70℃,V DD =4.5~5.5V,V SS =0V )参数符号 最小 典型 最大 单位测试条件传输延迟时间 t PLZ —— —— 300 ns CL=15pF ,DIN→DOUT,RL=10KΩ 下降时间 t THZ —— —— 120 µs CL=300pF,OUTR/OUTG/OUTB输入电容 C I————15pF——参数符号最小典型最大单位测试条件输入电流 I I —— —— ±1 µA V I =V DD /V SS 高电平输入 V IH 0.7V DD —— —— V D IN ,SET 低电平输入 V IL —— —— 0.3 V DD V D IN ,SET 滞后电压V H——0.35——VD IN ,SETLED 特性参数WS2813A WS2813B WS2813C WS2813D 静态电流 0.6mA 0.6mA 0.2mA 0.2mA RGB 通道恒流 15mA 15mA 5mA 5mA 红光亮度(中心值) 400mcd 300mcd 120mcd 100mcd 绿光亮度(中心值) 1250 mcd 1000 mcd 540 mcd 420mcd 蓝光亮度(中心值) 280mcd 210mcd 130mcd 110mcd 白光亮度(中心值) 1930mcd 1500mcd 790mcd 630mcd 红光波长 620-622nm 620-622nm 620-622nm 620-622nm 绿光波长 522-525nm 522-525nm 522-525nm 522-525nm 蓝光波长467-470nm467-470nm467-470nm467-470nm数据传输时间( TH+TL=1.25µs ±300n s )T0H 0码, 高电平时间 300ns~450ns T1H 1码, 高电平时间 750ns~1000ns T0L 0码, 低电平时间 300ns~100us T1L 1码, 低电平时间 300ns~100us RES帧单位,低电平时间300µs 以上时序波形图输入码型:连接方法:DIN DIN DIN DODODOPIX1D1D2D3D4PIX2PIX3数据传输方法:第一位24Bit 第二位24Bit 第三位24Bit 第一位24Bit 第二位24Bit 第三位24BitRERESET CODE >250usRERESET CODE >250usD1D2第二位24Bit 第三位24Bit 第二位24Bit 第三位24Bit第三位24Bit 第三位24BitD3D4注:其中D1为MCU 端发送的数据,D2、D3、D4为级联电路自动整形转发的数据。
R7R6R5R4R3R2R1R0G7 G6G5 G4G3 G2 G1G0 B7B6B5B4B3B2B1B0注:高位先发,按照RGB 的顺序发送数据。
回流焊指引无铅回流焊:含铅回流焊:曲线说明含铅回流焊无铅回流焊最低预热温度(Tsmin) 100℃150℃最高预热温度(Tsmax) 150℃200℃预热区时间(Tsmin to Tsmax)(ts) 60-120 S 60-180 S 平均升温速率(Tsmax to Tp) <3℃/S <3℃/S 液相温度(TL) 183℃217℃液相区保温时间(tL) 60-150 S 60-150 S 峰值温度(Tp) 215 ℃245℃高温区(峰值温度-5℃)停留时间(tp) <10 S <10 S 降温速率<6℃/S <6℃/S 室温至峰值温度停留时间<6 min <6 min回流焊说明1.回流焊不可以做两次以上2.当回焊时,不要在材料受热时用力压胶体表面烙铁焊接说明:1.当手工焊接时,烙铁的温度必须小于300℃,时间不可超过3秒2.手工焊接只可焊接一次修补说明:LED回流焊后不应该修补,当修复是不可避免的时,必须使用双头烙铁(如下图),但必须事先确认此种方式会或不会损坏LED本身的特性。
运输及存储1.运输及适用范围:所有产品在运输过程中,需保持正面朝上,防潮防水,运输过程中逼免挤压、碰撞和剧烈震动。
2.产品储存及期限:室温密封存储:20℃~30℃,40%~60%RH,产品有效期为1个月;防潮密封存储:20℃~30℃,25%~60%RH,产品有效期为 3 个月;产品拆包开封后,建议 2 小时内使用完成,(环境条件温度<30℃,湿度<60%)。
3. 除湿处理LED 产品超出以上规定期限,或者由于其他原因受潮,建议客户做除湿处理后再使用。
除湿方法:70℃-75℃/22±2 小时。
4. 静电防护LED 是静电敏感器件,虽然LED 产品具有优异的抗静电能力,但每经历一次静电释放产生的冲击,都会对LED 造成一定程度的损坏。
因而在使用LED 产品过程中需要做好静电防护措施,例如佩戴防静电手套及防静电手环等。
注意事项:LED封装为硅胶,用力按压胶体表面会影响LED可靠性,因此应有预防措施避免在封装的零件上的强大压力, 当使用吸嘴时,胶体表面的压力应是恰当的。
硅胶封装较柔软且有弹性,因它的特性大大减少了热应力,易受机械外力损坏,因此在手工处理方面须要对硅胶封装材料做预防措施,若未按要求操作,可能会导致LED损坏和光衰1. 通过使用适当的工具从材料侧面夹取2. 不可直接用手或尖锐金属压胶体表面,它可能会损坏内部电路3. 不可将模组材料堆积在一起,它可能会损坏内部电路4.不可用在PH<7的酸性场所标签Name:产品品名Quantity:数量Packing:封装尺寸Data:生产日期及产线载带规格(单位:mm)卷轴尺寸.防潮带包装。