Ultrasonic sensorUC4000-30GM-E6R2-V15R e l e a s e d a t e : 2016-04-25 09:35D a t e o f i s s u e : 2016-04-25102161_e n g .x m lDimensionsElectrical ConnectionPinoutTemperature probeCoded plug52225108ø40M30x1.527.536LED+ UB- UB12435(BN)(WH)(BK)(BU)(GY)Standard symbol/Connection:(version E6, pnp)Switch output 1Switch output 2Sync.Core colors in accordance with EN 60947-5-2.134521 BN2 WH3 BU4 BK 5GYWire colors in accordance with EN 60947-5-2(brown)(white)(blue)(black)(gray)Additional InformationSwitch point 1Switch point 2A 1 (N.O.)Switch output 1A 2 (N.O.)Switch output 2A 1 (N.C.)Switch output 1A2 (N.C.)Switch output 2A 1 (N.O.)Switch output 1A2 (N.C.)Switch output 2A 1 (N.O.)Switch output 1A2 (N.C.)Switch output 21. Switch point modeWhen A1 < A2, both switch outputs are activated as N.O. contacts.2. Window modeT o exchange the switching distances is of no effect. 3. Latching modeT o exchange the switching distances is of no effect. When A1 > A2, both switch outputs are activated as N.C. contacts. Possible operating modesR e l e a s e d a t e : 2016-04-25 09:35D a t e o f i s s u e : 2016-04-25102161_e n g .x m lDescription of Sensor FunctionsProgramming procedureThe sensor features 2 programmable switch outputs with programmable switch points. Programming the switch points and the operating mode is done either via the sensors RS232 interface and the ULTRA 3000 software (see the ULTRA 3000 software description) or by means of the programming plug at the sensors rear end which is described here.Programming switch points 1 and 21.Disconnect supply voltage2.Remove the programming plug to activate program mode.3.Reconnect supply voltage (Reset)4.Place the target at the desired switch point position for A15.Momentarily insert the programming plug in position A1 and then remove. This will program the switch point A1.6.Place the target at the desired switch point position for A27.Momentarily insert the programming plug in position A2 and then remove. This will program the switch point A2.Notes:•Removing the programming plug saves the new switch point position into the device memory.•The programming status is indicated by the LED. A flashing green LED indicates that the target is detected; a flashing red LED indicates that no target is detected.Programming the operation modeIf the program mode is still activated, continue at number 4. If not, activate program mode by performing the sequence numbers 1 to 3.1.Disconnect supply voltage2.Remove the programming plug to activate program mode.3.Reconnect supply voltage (Reset)4.Insert the programming plug in position E2/E3. By removing and reinserting the plug, the user can toggle through the three different modes of operation. The selected mode is indicated by the LEDs as shown below:•Switch point mode, LED A1 flashes •Window mode, LED A2 flashes•Latching mode, LEDs A1 and A2 flash5.Once the desired mode is selected, insert the programming plug in position T. This completes the programming procedure and saves the switch points and mode of operation.6.The sensor now operates in normal mode.Note:The programming plug also functions as the temperature compensation. If the programming plug has not been inserted in the T position within 5minutes, the sensor will return to normal operating mode with the latest saved values, without temperature compensation.Factory settingsSee technical data.DisplayThe sensor provides LEDs to indicate various conditions.Mounting flange, 30 mmBF 5-30Universal mounting bracket for cylindrical sensors with a diameter of 5...30mm UC-30GM-PROGULTRA3000Software for ultrasonic sensors, comfort line UC-30GM-R2V15-G-2M-PVCFemale cordset, M12, 5-pin, PVC cableGreen LEDRed LED Yellow LED A1Yellow LED A2During Normal Operation - Temperature compensated- with removed programming plug Interference (e.g. compressed air)On Off OffOff On FlashingSwitching state A1Switching state A1remains in previ-ous state Switching state A2Switching state A2remains in previ-ous stateDuring Sensor Programming Switch point A1: Object detected No object detected Switch Point A2: Object detected No object detected Operation mode: Switch point mode Window mode Latching mode Flashing Off Flashing Off On On On Off Flashing Off Flashing Off Off Off Flashing Flashing Off Off Flashing Off Flashing Off Off Flashing Flashing Off Flashing Flashing StandbyFlashingOffprevious stateprevious stateR e l e a s e d a t e : 2016-04-25 09:35D a t e o f i s s u e : 2016-04-25102161_e n g .x m lSynchronizationThis sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by applying an external square wave. The pulse duration must be ≥100 µs. Each falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for ≥ 1 second, the sensor will revert to normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input (see note below).If the synchronization input goes to a high level for > 1 second, the sensor will switch to standby mode, indicated by the green LED. In this mode,the outputs will remain in the last valid output state.Note:If the option for synchronization is not used, the synchronization input has to be connected to ground (0 V) or the sensor must be operated via a V1 cordset (4-pin).The synchronization function cannot be activated during programming mode and vice versa.The following synchronization modes are possible:1.Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs.In this case, each sensor alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pulses at the same time (see note below).2.Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are syn-chronized by a common external synchronization pulse.3.A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode (see note below).4.A high level (+U B ) on the synchronization input switches the sensor to standby mode.Note:Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplex-ing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time.Note on communication with the UC-30GM-R2 interface cableThe UC-30GM-R2 interface cable allows for communication with the ultrasonic sensor using ULTRA3000 software. The cable creates a connection between a PC RS-232 interface and the programming plug socket on the sensor. When connecting to the sensor, make certain the plug is lined up correctly; otherwise no communication will be possible. The key of the cable’splug must be aligned to the groove of the socket on the sensor (not with the arrow symbol on the sensor).Programmable parameters with the ULTRA3000 software•Switch point 1 and 2•NO/NC function•Operation mode •Sonic speed•Temperature offset (The inherent temperature-rise of the sensor can be considered in the temperature compensation)•Expansion of the unusable area (for suppression of unusable area echoes)•Reduction of the detection range (for suppression of remote range echoes)•Time of measuring cycle•Acoustic power (interference of the burst duration)•Sensitivity•Behaviour of the sensor in case of echo loss •Behaviour of the sensor in case of a fault•Average formation via an allowed number of measuring cycles •On/off-delay•Switching hysteresis•Selection of the parameter set, RS 232 or manually Note:When connected to a PC and running the ULTRA3000 software, the sensor can act as a long term data logger as well.。

来扬LYZZC-III-10A 直流电阻测试仪 使用手册说明书

来扬LYZZC-III-10A 直流电阻测试仪 使用手册说明书

LYZZC-III-10A直流电阻测试仪使用本仪器前,请仔细阅读操作手册,保证安全是用户的责任!注意:LYZZC-III直流电阻测试仪采用交直流两种供电方式,采用直流方式时严禁电池工作在极度缺电状态下,如电量不足请及时对电池充电,仪器长时间不使用时,应定期对电池充电,以免造成电池由于电量不足而损坏电池。

一、安全措施1、使用本仪器前一定要认真阅读本手册。

2、仪器的操作者应具备一般电气设备或仪器的使用常识。

3、本仪器户内外均可使用,但应避开雨淋、腐蚀气体等场所使用。

4、仪表应避免剧烈振动。

5、对仪器的维修、护理和调整应由专业人员进行。

6、测试完毕后一定要使仪器复位后关闭电源再拆除测试线。

7、测试过程中,禁止移动测试夹和供电线路。

二、功能特点1、整机由高速单片机控制,自动化程度高,操作简便。

2、仪器采用全新电源技术,测量范围宽。

3、保护功能完善,能可靠保护反电势对仪器的冲击,性能更可靠。

4、响应速度快,仪器测量数据稳定,仪器测试过程中自动刷新数据。

6、智能化功率管理技术,仪器总是工作在最小功率状态,有效减轻仪器内部发热,节约能源。

7、仪器内部带有不掉电时钟。

8、仪器内部具有不掉电存储器,可永久保存数据。

三、技术指标1、输出电流:10A、5A、1A、200mA、40mA、<5mA2、分辨率:0.1μΩ3、量程: 100Ω-20KΩ (<5mA档)1Ω-250Ω (40mA档)100mΩ-50Ω (200mA档)5mΩ-10Ω (1A档)1mΩ-2Ω (5A档)0.5mΩ-1Ω (10A档)4、准确度:0.2%5、工作温度:0~40℃6、工作湿度:<90%RH,不结露7、外形尺寸:长325mmX宽240mmX高275mm四、系统介绍 仪器的面板见下图电 源 仪器工作电源,AC220V。

复 位 键 按下此按键本机处于初始状态,可对输出电流进行预置。

循 环 键 按此键光标在主菜单循环滚动选 择 本机复位后,按此键进行电流预置。

吉高电声测试仪使用说明

吉高电声测试仪使用说明

目 录1. 概述 P02 2. 主要技术指标 P02 3. 工作原理 P034. 操作说明 P03 4.1 仪器输入输出介绍 P03 4.2 软件清单 P06 4.3 测试软件选择 P07 4.4 功能键操作说明 P08 4.5 〈F5〉设置项目说明 P10 4.6 屏幕打印和发E-MAIL 邮件 P185. 测试说明 P18 5.1 受话器测试 P19 5.2 麦克风或送话器测试 P23 5.3 驻极体传声器测试 P27 5.4 单耳机和传声器组测试 P31 5.5 左右耳机和传声器组测试 P355.6 助听器测试 P39 5.7 蜂鸣器测试 P45 5.8 扬声器和音箱测试 P49 5.9 多媒体音箱测试 P55 5.10 音箱分频器和电路频响测试 P57 5.11 音频功放测试仪 P60 5.12 超声波器件/蜂鸣器电声参数测试仪 P636. 故障检查方法 P72 7. 注意事宜 P74 8. 仪器清单 P75特别申明:1、概述CRY6125系列电声器件测试仪是一台全功能电声器件测试仪。

测量麦克风、驻极体传声器(咪头)、送话器、受话器、耳机、耳机传声器组、通信帽等的1KHz灵敏度,平均功率灵敏度,灵敏度频率特性曲线,阻抗、阻抗频率特性曲线,及失真度等指标。

测量扬声器及音箱的灵敏度频率特性曲线谐振频率FO及品质因素Q值,扬声器的等效容积。

测量音箱分频器的频率,和分频点的阻抗。

测量电磁式蜂鸣器,压电蜂鸣器,和超声波器件的灵敏度频率特性曲线和谐振频率FO。

测量助听器和音频功放性能。

或作频谱分析。

具备抗环境噪音功能,测量频率可达10Hz -- 65KHz。

仪器由计算机、显示器、信号源、测量放大器、仿真耳、仿真嘴及相关附件共七部份组成。

由于CRY6125具备抗环境噪音功能,所以测试性能相当稳定,无需消声室环境。

可直接在屏幕上编辑频响曲线容差框,容差框可自由设定或来自测试曲线,比较方法有归零法,入框法,或定框法。

噪音传感器说明书

噪音传感器说明书

噪音传感器说明书一、产品概述:我司生产的噪音传感器是采用工业标准的噪声监测仪,针对工业现场噪声测试需求而设计,兼容监控系统,对噪声进行定点全天侯监测。

可广泛用于仓库、机房、生产车间、档案室、图书馆、学校、商场、智能家居、楼宇控制、机场、火车站等领域。

二、参数供电电压:默认DC12V;可选DC24V或DC5V测量范围:30dB to130dB(自动换挡)采样频率:一秒采集500次输出频率:RS232信号一秒两次、RS485一秒一次、模拟量连续输出输出模式:RS232‐ASIIC码输出、RS485‐Modbus协议、模拟量为:电流或电压测量误差:+/‐1.5dB(2Khz80dB点校正)转换精度:0.1dB频率加权特性:A加权特性动态特性:FAST响应时间:小于2秒频率响应:35Hz to20KHz产品尺寸:直径M24mm长度80毫米,输出线长2.0米工作环境:温度-20~60℃湿度10~90%RH存储环境:温度-20~80℃湿度10~90%RH三、型号出线定义:RS232输出:型号WS600A;红线V+,黑线V‐、RS232输出端为黄线RS485输出:型号WS800A;红线V+,黑线V‐、白线A+、黄线B‐4‐20mA输出:型号WS500A;红线V+,黑线V‐、黄线电流输出I+0‐5V输出:型号WS400A;红线V+,黑线V‐、黄线电压输出VoRS232串口模式:RS232通讯模式9600,n,8,1;信息ASIC字符输出“N:045.6dB”+Enter。

对应测量值为45.6分贝,Enter对应16进制0x0a+0x0d,输出间隔500ms/次。

四、通信说明:(只针对于RS232RS485和无线输出型)4.1查询地址为1的仪表的噪音值(读输入寄存器)01040000000131CA 地址功能码第一个寄存器地址读输入寄存器的数量CRCL CRCH 从机应答:010402xxxxCRCL CRCH010402xxxx CRCL CRCH 地址功能码数据量分贝值(Hex)CRCL CRCH 4.2查询地址为1的仪表读保存寄存器读保存寄存器(4X类型)中的二进制数据,寄存器所对应的地址分别为0-134.3写入单个保存寄存器,读从机输入寄存器(4X类型)中的二进制数据,寄存器所对应的地址分别为0-13写入把地址1改地址24.4写入把地址波特率修改为4800(4800的16进制为12C0)读从机输入寄存器(4X类型)中的二进制数据,寄存器所对应的地址分别为10五、模拟量输出计算公式:4‐20mA输出算法:负载:250欧‐‐‐‐750欧输出:4mA‐20mAdB=(Ix–4)*6.25+30;Ix=(I1+I2+I3---+I100)/X;一秒之内取X个电流值取其平均值。

Philips AZ215S CD音響機產品說明说明书

Philips AZ215S CD音響機產品說明说明书

PhilipsCD 音響3 瓦數碼選台AZ215S隨時隨地享受音樂每個人都喜歡享受生活中的簡約和方便。

透過簡單易用的功能,方便攜帶的Philips CD 音響,讓您陶醉於最喜愛的音樂中。

享受不同來源的音樂•播放 CD、CD-R 及 CD-RW•FM 立體聲選台器•音訊輸入,可輕鬆便攜播放音樂方便使用•CD 隨機/重複功能提供個人化音樂享受•可編排 20 首 CD 曲目•20 個預設電台豐富、清晰的音響體驗•動態低音增強效果,提供更深沉、震撼的音效•3W RMS總輸出功率出版日期 2017-05-16版本: 1.0.812 NC: 8670 001 29216EAN: 48 95185 61580 6© 2017 Koninklijke Philips N.V.版權所有。

規格若有變更恕不另行通知。

商標為 Koninklijke Philips N.V. 或其個別所有者的財產。

規格CD 音響銀色 3 瓦, 數碼選台產品特點播放CD 、CD-R 及 CD-RWPhilips 以製造可兼容市場上大多數光碟的產品而聞名於世。

這款音響系統讓您可欣賞到來自 CD,CD-R 和 CD-RW 的音樂。

CD-RW (CD-Rewritable Compatible) 表示您的音響系統可以播放 CD-R 和 CD-RW 光碟。

CD-R 光碟是一次燒錄的,可以在任何 CD 播放機上播放,而 CD-RW 光碟可以多次錄製和重複抹寫,只能在兼容的CD 播放機上播放。

CD 隨機/重複「隨機/重複」功能幫助您從此告別總是按同一順序聆聽音樂的厭倦感。

將最愛歌曲載入播放器後,只要選擇「隨機」或「重複」模式之一,便可以不同模式順序播放歌曲。

每次接通播放器時,都能體驗到不同的非凡音樂體驗。

可編排 20 首 CD 曲目可編排 CD 播放的功能,讓你依所需順序欣賞喜歡的曲目。

Dynamic Bass Boost動態低音增強可在音量設定範圍內加重音樂的低音部份,讓你獲得極致的音樂享受 - 從低音到高音,只要一個按鍵即可設定完成!當音量設定比較低時,最低的低音頻率經常會遺失。

TYPE 152导航指示器试验器使用说明

TYPE 152导航指示器试验器使用说明

机载电子设备维修技术人员培训系列教材机载电子设备试验器使用操作说明 TYPE 152导航指示器试验器作 者: 贺 军笔 名: STDHJ(作者:贺军 中信海直通用航空维修工程有限公司 电子工程师)“TYPE 152导航指示器试验器”是中信海直通用航空维修公司制作的用于检测“TYPE 152导航指示器”的试验设备第一章:机载电子设备维修检测基本方法:第一节:检修程序:1、了解情况:1.1、维修人员接收到送检故障件后首先要通过送检故障单,阅读送检设备部件的历史资料等,了解故障现象和分析故障原因,作出初步故障判断。

1.2、按照送检设备件号查询和准备与该部件相符合的维修手册和相关技术资料,准备试验器和检测设备及连接电缆等附件。

1.3、如果送修件不是自己非常熟悉该设备电路原理和已经对该部件很有维修经验的时候,首先要静下心来认真消化该设备部件的维修手册,熟悉该部件整机电路工作原理和认真分析有可能与故障相关的电路。

1.4、按照维修校验规程连接好试验器、检测设备、故障部件。

1.5、按照校验规程检测故障部件,确认送检部件是否与送检故障相符。

2、检查压缩故障点:检查压缩,就是利用静态和动态实施检修的过程。

首先要进行对保险装置的检查,保险装置包括安装在部件上的速熔断保险丝、电源保安反向接入二极管、稳压二极管等进行检查,如有故障首先予以排除,保险装置检查合格后,方可通电检测。

常言道要“通过现象看本质”,检修故障也是如此,要能够顺利的压缩故障点,首先要认真、仔细、全面、准确地观察该部件故障现象,观察看电路板上有没有烧黑损坏的元器件,电路板上有没有异常的地方等,把握了故障现象在理论的指导下,作出正确的分析判断,按照一定的检修原则和方式,便可排除故障点。

3、修复检验:在检查压缩到故障点后,应立即修复,然后要加以检验。

检验的内容包括工艺焊接质量、机械性能和电气技术性能是否合格等。

检验方法应根据具体情况和校验规程条件确定,最简单的故障维修也要经过调整使用、试机,运用测试仪表和试验器进行技术指标检查,以确保主要技术性能指标达到维修手册的要求。

ZWV二代变频空压机使用手册

ZWV二代变频空压机使用手册
3. 运转操作................................................................................................................................................... 21 3-1 运转前检查.................................................................................................................................... 21 3-2 初次运转 ........................................................................................................................................ 22 3-3 例行运转 ........................................................................................................................................ 24 3-4 运转说明 ........................................................................................................................................ 25 3-5 长期停机 ........................................................................................................................................ 25 4-1 清洁前置过滤网 4-2 主要零件保养.......................................................................................... 27 4-2 主要零件保养................................................................................................................................ 28 4-3 进气阀调整.................................................................................................................................... 41 4-4 自动补泄水系统 ........................................................................................................................... 45 4-5 自动换水功能................................................................................................................................ 52 4-6 马达轴承润滑................................................................................................................................ 52 4-7 保护功能 ........................................................................................................................................ 53 4-8 故障排除指南................................................................................................................................ 54 4-9 ZW 型-螺旋式空压机压缩原理................................................................................................... 57 备品明细表………………………………………………………………………………………56

YAV SmartV智能记录仪技术手册V1708

YAV SmartV智能记录仪技术手册V1708

YAV SmartV智能记录仪技术手册V1708武汉亚为电子科技有限公司关于本手册为亚为推出的SmartV智能记录仪的用户手册,主要内容包括功能概述、6路模拟量输入功能、2路数字量输入功能、应用实例、性能测试、注意事项及故障排除等。

另外DI采集包含需要定制的特殊功能:PWM功能输入,编码器输入,AO输出匹配输入。

SmartV智能记录仪是武汉亚为科技倾力推出的全国首款智能型多功能离线采集设备。

该设备获实用新型专利。

自动、简洁的使用理念,可像手机一样通过安装不同的APP完成不同测试功能,离线采集技术突破了传统数据采集依赖于电脑或网络的限制,环境适应性达到了工业标准。

说明序号版本号编写人编写日期支持对象应用时间特别说明1 1.0齐非2014.01Smart V2016.012 2.0樊春晖2016.01Smart V2017.013 3.0郑先科2017.01Smart V2017.084 4.0郑冉2017.082017.08目录0.快速上手 (1)产品包装内容 (1)接口定义 (1)⏹端子排列 (1)⏹端子描述 (1)1.产品概述 (2)技术指标 (2)⏹模拟信号输入 (3)⏹数字信号输入 (4)⏹内存 (4)⏹通信总线 (4)⏹供电 (4)⏹温度参数 (4)⏹其他 (4)硬件特点 (5)原理框图 (6)采集卡指示灯 (6)机械规格 (7)2.采集卡信号接线 (8)AI模拟量接线 (8)DI数字量接线 (9)DO数字量接线 (9)3.模拟量输入功能 (10)模拟量输入 (10)输入采样原理 (10)输入接线 (10)采样值计算 (11)⏹无符号整型 (12)⏹ADC数据类型 (12)⏹模拟量值 (12)4.数字量输入功能 (13)数字输入原理 (13)DI高低电平/无源触点输入 (13)5.应用实例 (14)应用领域 (14)使用方法 (17)⏹作为U盘直接连接电脑 (17)⏹修改配置文件 (17)⏹数据采集与存储 (18)⏹数据的读取分析 (18)6.性能测试 (18)安全规范 (18)耐电压范围测试 (19)环境适应性测试 (19)电气参数 (20)7.注意事项及故障排除 (21)注意事项 (21)⏹存储说明 (21)⏹出货清单 (21)⏹质保及售后 (21)⏹特别说明 (22)故障排除 (22)⏹无法正常连接至上位机 (22)⏹读数异常 (22)⏹采集速度不够 (22)⏹其他错误 (22)8.文档权利及免责声明 (23)9.联系方式.........................................................................................................................错误!未定义书签。

电压监测仪 技术说明书(液晶)

电压监测仪 技术说明书(液晶)
输入日、时,各输入两位,如不需设定次参数按[设定]键跳过此项
分·秒设置
P3 - - - -
输入分、秒,各输入两位,如不需设定次参数按[设定]键跳过此项
额定值设置
P40000
设定仪表的监测电压等级:
1规格为DY2-100、57.7/G,可有9种设置
0003kV
0006kV
0010kV
0035kV
0063kV
2主要特点
真有效值测量:直接显示被测电压瞬时有效值。
仪表采用液晶显示方式,数据及状态直观明朗。
仪表采用自诊断和自修正技术,能适应较恶劣的环境,保证其较高的测量精度和稳定性。
仪表采用大容量失电不挥发的串行输入输出高速存储器、机内存贮12个月数据,断电数据永久保存。
可远程设定。
3基本功能
每小时合格、超上限、超下限、失电分钟数。
短接端口1,2为100V;
短接端口1,3为220V;
端口3,4为380V;
7.3显示说明
监控状态下即显示电压值及当前时间,如下图:
我们提供了查询“基本功能”中的功能,按↑、↓键进行循环,选择好后按下 (确认)键。如显示“最大值”功能:
在此界面下,按下↓键,可看出最大值出现的时间,如下图:
注:其他功能操作与上述方法大致相同,通过4个按钮选择。
10质量保证及服务…………………………………………………………10
1概述
DY2型电压监测仪,是依据电力行业标准《DL500-2009电压监测仪订货技术条件》开发研制的,专门用于监测电网电压的运行质量的电子仪表,主要由计算机、电压监测仪、监测数据分析管理系统等组成,其中GPRS型和短消息型电压监测仪还包括:短消息无线数据采集器、GPRS数据服务器和客户端上位机数据管理系统等组成的一个电压监测网络系统,它利用现有的GPRS网络或短消息无线数据采集器把现场数据发送或接受到远程的GPRS数据服务器上或装有短消息无线数据采集器服务器上,通过INTERNET网络把这些数据发送或接受到远程电力部门的客户端上位机管理系统上,实现对现场仪表数据的远程无线采集和监控。该仪器以单片机和GSM/GPRS无线网络技术为核心,集监测,记录,远程通讯于一体的智能化仪器。产品采用了大规模的集成电路技术,高精度A/D转换技术,单片机控制技术和抗干扰技术,具有测量精确,可靠性高,功能齐全,人机界面友好,安装方便,操作简单等特点,在同类产品中具有很高的性能价格比。它具有对电网电压进行实时监测、数值统计分析、存储和多种形式的报表打印等功能,并采用GPRS/GSM(短消息)通讯方式来收发数据,是新一代高科技管理系统。该系统具有建网方便、无需布线、一次性投资少、设备运行维护费用低和几乎不受区域限制等特点。

YAV Z2声音传感器(交流电压输出)技术手册YAV5152Z2

YAV Z2声音传感器(交流电压输出)技术手册YAV5152Z2

YAV-Z2声音传感器(交流输出)技术手册YAV Z2声音传感器(交流输出)技术手册V1801武汉亚为电子科技有限公司YAV5152Z2关于序号版本号编写人编写日期支持对象应用时间特别说明1 1.0齐非2013.11YAV-Z12013.111 2.0郑冉2014.01YAV-Z12014.011 3.0朱健波2016.08YAV-Z12016.081 4.0朱健波2017.08YAV-Z12017.08目录0.快速上手 (1)产品包装内容 (1)接口定义 (1)1.产品概述 (1)技术指标 (2)硬件特点 (2)2.传感器的安装及固定 (3)3.电压对应声压级表(非线性) (4)4.性能测试 (5)噪音波形 (5)安全规范 (5)环境适应性测试 (6)5.注意事项及故障排除 (8)注意事项 (8)⏹存储说明 (8)⏹出货清单 (8)⏹质保及售后 (8)⏹特别说明 (8)故障排除 (8)6.文档权利及免责声明 (10)7.联系方式.........................................................................................................................错误!未定义书签。

8.V智能体验 (11)0.快速上手本章主要介绍初次使用YAV-Z2噪音传感器需要掌握的知识,以及与使用相关的准备工作,可以帮助用户熟悉YAV-Z2使用流程,快速上手。

产品包装内容YA V-Z2噪音传感器、包装盒各一个,开发资料(官网下载)。

接口定义端子定义说明:●红色为电源正极●绿色为电源负极●黄色为信号线1.产品概述YAV-Z2噪声传感器具有声级计的全部功能,DC12V供电,并克服了传统手持式声级计信号输出复杂、感应不远的缺点,可采集声音波形信号。

十分方便的与PLC、PC、DCS等控制设备兼容而组成的精细噪声测量系统,特别适合集成于各种环境、产品监控设备,组成单点或多点噪声监控网络,是各类噪声源的噪声监控、检测、监测、实验的理想选择。

ZN4122A 音频分析仪 使用说明书

ZN4122A 音频分析仪 使用说明书

使用前请先阅读使用说明书ZN4122A音频分析仪使用说明书北京大泽科技有限公司BEIJING DA ZE TECHNOLOGY CO.,LTD电话:传真:目录一、概述 (2)二、工作特性及指标 (2)三、整机方框图 (5)四、面板描述 (6)五、操作说明 (11)六、整机配置 (18)七、常用分贝表 (18)八、本仪器的环境使用条件和维护 (18)电话:************传真:************ 1一、概述ZN4122A音频分析仪是一台同时具有低失真信号源输出及小失真测量的全自动数字化的通用测量仪器,信号源的输出幅度、频率及被测信号的电压、失真、频率测量全部采用彩色液晶显示,对所有信号源输出信号都可存贮,具有失真小,输出有效范围大,操作全部键盘化的特点。

信号源可产生频率为5Hz~199.9kHz,电压为 -72.5dB~ +7.5dB的信号,电压测量可在输入电压范围为30μV~100V,频率范围为5Hz~300KHz内实现全自动测量,失真测量可在输入电压范围为100mV~100V,频率范围为5Hz~199.9kHz内自动测量,失真测量范围为100%~0.003%,最小失真可测0.0025%,同时还具有测量S/N(信噪比)的功能。

幅度显示单位为V、mV、dB、dBm,失真度显示单位可选择%、dB。

S/N 显示单位为dB。

该仪器内设400Hz高通,30K、80K低通滤波器使用十分方便,是一台具有自动测量信号电压、失真和信号源输出等多种功能的智能型仪器,可供科研、工厂、院校、实验室使用。

本仪器在此条件下可连续工作8小时,预热半小时后能达到以下工作特性。

二、工作特性及指标音频信号分析部分(一)频率准确度±5%±1Hz(二)失真度测试1:频率范围:5Hz~199.9kHz2:输入信号电压范围: 100mV~100V3:失真度测试范围: 输入电压:1V~100V 100%~0.003%电话:************传真:************ 2输入电压:100mV~1V 100%~0.03% 4:准确度:20Hz~19.99kHz±1dB (100% ~0.003%)带宽80kHz7Hz~20Hz±1.5dB (100% ~0.003%)带宽80kHz20kHz~49.99kHz±1.5dB(100% ~0.03%)带宽600kHz50kHz~199.9kHz±2dB(100% ~0.1%)带宽600kHz5Hz~7Hz±2dB (100% ~0.1%)带宽80kHz失真度在0.03%以下及输入信号在100mV~500mV时测量误差为±2dB 5:残余失真和噪声(输入电压1V以上)(噪声测量时输入端短路)20Hz ~ 19.99kHz ≤ 0.0025%以下带宽80kHz7Hz~20Hz 0.007%以下带宽80kHz20kHz~50kHz 0.007%以下带宽600kHz50kHz~199.9kHz 0.05%以下带宽600kHz5Hz~7Hz 0.05%以下带宽80kHz(三)电压测试1:电压测试范围:100V ~30μV (+40dB ~ -90dB)2:频率范围:5Hz ~ 300kHz3:以1kHz为基准的频响20Hz~100kHz±1dB5Hz ~300kHz±1.5dB4:电压表准确度(以1kH为基准)±5% -90dB±10%5:固有噪声≤10μV(输入端短路)6:电压表有效值波形误差≤3%(输入信号波峰因数≤3时)(四)信噪比(S/N)电话:************传真:************ 31:测量范围: 0 ~ -90dB(0 ~ -90dB 10个量程)2:信号范围: 100mV~100V-100dB以下 80k带宽(输入1V以上)-90dB以下600k带宽(输入1V以上)(五)本仪器定义0dB=1Vrms(测量功率时0dB=0.775V即1mW,在600Ω负载上测量功率时,所有dB读数需在当前dB读数上加2.22 dB即为dBm数值)(六)输入阻抗:100 kΩ//100PF音频信号发生部分电压范围:+7.5 dB ~ -72.5 dB(0.237mV~2.37V)频率范围:5Hz~199.9kHz(一)频率准确度±2%±1Hz(二)频率特性:以1kHz为基准50Hz~19.99kHz ±1dB5Hz~199.9kHz ±1.2dB(三)电压准确度:以1kHz为基准-32.5dB~+7.5dB ±0.5dB-32.6dB以下±1dB(四)失真度:输出电压1V以上20Hz~19.99kHz 0.0025%以下带宽80kHz7Hz~19.9Hz 0.007%以下带宽80kHz20kHz~49.9kHz 0.007%以下带宽600kHz50kHz~199.9kHz 0.05%以下带宽600kHz5Hz~6.9Hz 0.05%以下带宽80kHz电话:************传真:************ 4电话:************ 传真:************ 5(五)输出阻抗: 600Ω±10%(六)因阻抗匹配的原因,信号源输出电压在电压表的读数时要加6dB 。

VELTRON II 智能气流传感器说明书

VELTRON II 智能气流传感器说明书

VELTRON IIMicroprocessor BasedPressure & Flow “Smart” TransmitterPrecision Airflow MeasurementAn ON I CON BrandAccurate airflow measurement for demanding applicationsThe VELTRON II transmitter is furnished with an automatic zeroing circuit capable of electronically adjusting the transmitter zero at predetermined time intervals while simultaneously holding the transmitter output signal.The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For transmitters operated in temperature controlled spaces (with no thermal effectupon span), this automatic zeroing function essentially produces a “self-calibrating” transmitter. The automatic zeroing circuit will re-zero the transmitter to within 0.1% of its operating span; for a transmitter with a 0.02 IN w.c. operating span, this represents a zeroing capability within 0.00002 IN w.c.To permit manual calibration of the VELTRON II, an electronic switch is provided to permit manual positioning of the zeroing valve.with Automatic Zeroing CircuitSpan Rangeability . The calibrated span can be down ranged to 40% of the Natural Span.Stability . ±0.5% of Natural Span for six months.Transducer Response Time . 0.5 second to reach 98% of a step change.Temperature Effect . Zero. None; corrected by AUTO-zero.Span. 0.015% of Full Span/ºF.Mounting Position Effect . None; corrected by AUTO-zero.Ranges . Natural SpansBi-Polar Natural Spans 0 to 25.00 IN w.c. 0 to 10.00 IN w.c. –10.00 to 10.00 IN w.c. 0 to 5.00 IN w.c. – 5.00 to 5.00 IN w.c. 0 to 2.00 IN w.c. – 2.00 to 2.00 IN w.c. 0 to 1.00 IN w.c. – 1.00 to 3.00 IN w.c. 0 to 0.50 IN w.c. – 0.50 to 0.50 IN w.c. 0 to 0.25 IN w.c. – 0.25 to 0.25 IN w.c. 0 to 0.10 IN w.c. – 0.10 to 0.10 IN w.c.0 to 0.05 IN w.c.– 0.05 to 0.05 IN w.c.Accuracy . 0.1% of Natural Span, including non-linearity, hysteresis, deadband, and non-repeatability.Performance SpecificationOverpressure and Static Pressure Limit . 25 psig.Low Pass Filtration . Response time to reach 98% of a step change is adjustable from 2.0 to 250.0 seconds.Automatic Zeroing . Accuracy. Within 0.1% of calibrated span. Frequency. Every 1 to 24 hours on 1 hour intervals.Circuit Protection . Power input is isolated, fused, and reverse polarity protected.Span and Zero Adjustment. Electronic adjustment via keypad.Display. Standard 2 line x 20 characters LCD provides one line of data display. Optional (standard on MASS-tron II) backlit, graphical LCD provides indication of up to four processvariables. Triple-size digits for main process variable, standard size characters for the other process variables.Humidity Limits . 0-95% RH, non-condensing.Temperature Limits . –20 to 180ºF Storage. +40 to 140ºF Operating.Digital Outputs . Form C dry contacts rated for 3 amps at24VAC/VDC for optional HI/LO alarm. Dual Form A dry contacts rated for 3 amps at 24VAC/VDC for AUTO-purge activation and acknowledgment.Digital Inputs . Dry contact for AUTO-purge external start.Analog Outputs . Dual transmitter outputs are individually configurable via jumper for 0-5VDC, 0-10VDC, or 4-20mADC. Two additional outputs are optionally available.Analog Inputs . A single input is field configurable via jumper for 0-5VDC, 0-10VDC, or 4-20mADC. For use with optional special function.Network Communication. Optional ModBus TCP/IP over Ethernet or LonWorks.Power Supply . Standard 24VAC (20-28VAC) or 24VDC (20-40VDC). Optional 120VAC (100-132VAC), via external transformer.Power Consumption . Standard: 18VA at 24VAC; 13VA at 24VDC; 36VA at 120VAC. With AUTO-purge Management: 54VA at 24VAC; 48VA at 24VDC; 108VA at 120VAC.Functional SpecificationSignal Connections . High and low pressure, 1/8” FPT.Electrical Connections . External terminal strip with plug-in connectors. Optional terminal strip enclosure with dual 3/4” (.875” actual)conduit connections.Physical SpecificationsEnclosure . NEMA 1 aluminum enclosure.Weight . 4.1 lbs.Dimensional SpecificationsSuggested SpecificationThe transmitter shall be capable of receiving flow signals (totaland static pressure) from an airflow station or probe array and produce dual outputs linear and scaled for air volume, velocity, differential pressure, etc.The transmitter shall contain an integral multi-line digital display for use during the configuration and calibration process, and to display one transmitter output during normal operating mode. All transmitter configuration, parameter setting, zero and span calibration, plus display formatting and scaling will be performed digitally in the on-board microprocessor via input pushbuttons.The transmitter will be available in multiple natural spans covering the range of 0.05 IN w.c. to 10.0 IN w.c. with an accuracy of 0.1% of natural span. The transmitter shall be furnished with a transducer automatic zeroing circuit and be capable of maintaining linear output signals on applications requiring 10 to 1 velocity (100 to 1 pressure) turndown.The transmitter shall be capable of having its operating span electronically selected without having to perform recalibration involving an external pressure source.(Optional) The transmitter shall be capable of receiving an external temperature input, internally perform density correction for the process absolute pressure and temperature, and provide individual analog outputs linear and scaled for standard air volume or mass flow, temperature and absolute pressure.(Optional) The transmitter shall include an integral P,I,1/D three-mode controller capable of controlling at a user selectable internal or external setpoint, and providing an analog output control signal.(Optional) The transmitter will provide the means of managing a system for automatic high pressure purge of the airflow station or probe array, with user selectable purge frequency and duration, while maintaining the last transmitter output during the purge cycle.(Optional) Using a second transmitter as an input, the internal microprocessor can perform a summed flow, flow differential, low signal select, high signal select or percent deviation calculation, with the result being displayed and provided as an analog output signal.The transmitter shall be the VELTRON II [MASS-tron II or VEL-trol II] as manufactured by Air Monitor Corporation, Santa Rosa,California.Via the addition of both process temperature and pressure compensation, the ultra high accuracy VELTRON II becomes the MASS-tron II multi-variable mass flow transmitter. The process temperature input is an analog signal from a remote 4-wire or loop powered temperature transmitter; with the MASS-tron II having the capability of performing the linearization. The process pressure is measured by means of an internal absolute pressure transducer connected to the transmitter’s static pressure signal input.Performance SpecificationsIn addition to those available with the VELTRON II, the MASS-tron II includes these performance specifications:Analog Output. 0-5VDC, 0-10VDC or 4-20mA for process differential pressure, temperature, and absolute pressure.Analog Input. 0-5VDC, 0-10VDC or 4-20mA for process temperature.Temperature Compensation Selection. Pushbutton selection of linearized or non-linearized input, thermocouple or 100 ohm platinum RTD temperature sensor type: Type E -50 to 1750ºF -50 to 950ºC Type T -50 to 750ºF -50 to 400ºC Type J -50 to 2000ºF -50 to 1090ºC Type K -50 to 2000ºF -50 to 1090ºCRTD-50 to 1500ºF-50 to 815ºC*Shown with standard 4-line graphic LCD The VEL-trol II incorporates a controller into the ultra high accuracy VELTRON II transmitter, providing the three modes of proportional, integral reset, and inverse derivative to permit the controller to be tuned to the extreme dynamics of critical airflow and pressurization control processes. The selection of the P,I,1/D tuning parameters is accomplished using the password protected membrane switch pushbuttons on the front of the enclosure. By means of a dry contact input, the controller operating set point can be switched from the internal fixed setpoint to an externally provided fixed or variable input.Performance SpecificationsIn addition to those available with the VELTRON II, the VEL-trol II includes these performance specifications:Analog Output. 0-5VDC, 0-10VDC or 4-20mA for controller output.Analog Input. 0-5VDC, 0-10VDC or 4-20mA for controller external setpoint.Digital Input. Dry contact for soft start command.*Shown with optional 4-line graphic LCD Pressure Compensation. Absolute pressure (atmospheric or duct static), up to 60 IN Hg.For optional CE certification, the MASS-tron II is furnished in a NEMA 4 enclosure (not shown).For optional CE certification, the VEL-trol II isfurnished in a NEMA 4 enclosure (not shown).Construction FeaturesAccuracy . The VELTRON II is designed to maintain an accuracy of 0.1% of Natural Span. For a span of 0 to 0.05 IN w.c., this accuracy is equivalent to an output accuracy of ±0.00005 IN w.c. differential pressure or 0.45 FPM velocity at span.Continuous Display of Process . All VELTRON II’s are equipped with a 2x20 liquid crystal display (LCD) for use during the configuration and calibration process, and to display one transmitter output during normal operating mode. Standard on the MASS-tron and optional for both the VELTRON II and VEL-trol II is a multi-line, backlit, graphical LCD providing up to four lines of data display, with each line individually scalable in user selectable format and units of measure. For high visibility, the main process variable (flow) is displayed with easy-to-read, triple-size digits. Other process variables are displayed with standard size digits.Analog Communication . Each analog input and output signal can be individually configured for 0-5VDC, 0-10VDC, or 4-20mADC by means of a single jumper.Electronic Respanning . The VELTRON II operating span can be electronically selected anywhere between the Natural Span and 40% of Natural Span, without having to perform recalibration involving an external pressure source.Primary Signal Noise Filter . To eliminate background noise and pulsations from the flow signal, the VELTRON II is equipped with a user selectable digital low pass filter.High Turndown Ratio Operation . The VELTRON II, with its high level of accuracy and automatic zeroing circuitry, can maintain linear output signals on applications requiring velocity turndown of 10 to 1 (equal to a velocity pressure turndown of 100 to 1).Microprocessor Based Functionality . The VELTRON II’s on-boardFeaturesmicroprocessor performs the functions of operating parameter selection, transmitter configuration, input/output and display signal scaling, and transducer calibration. Imbedded software performs span, flow, and 3-point “K” factor calculations. Input to the micro-processor is via pushbutton.AUTO-purge Management (optional). For “dirty air” applications requiring the use of an Air Monitor AUTO-purge system, the VELTRON II provides the capabilities of establishing purge frequency and duration while giving the user a choice of either internally timed cycle frequency or externally triggered purge initiation. During the purge cycle all transmitter outputs are maintained at their last value prior to the start of the purge cycle.Special Functions and Alarm Capability . The VELTRON II is capable of performing one of five special application functions using a second transmitter as an input: Summed flow, flow differential, low signal select, high signal select, or percent deviation. The special function output can be both displayed and provided as an analog output signal. Alarms related to the measured process can be configured for one of three modes: Low/Low, High/Low, and High/High.Multiple Operating Power Selections . Standard input power supplied to the VELTRON II can be either 24VAC or 24VDC via automatic selection. An optional 120VAC external power transformer (UL listed) can be provided.CE Certification . For optional CE Certification, the VELTRON II is furnished in a NEMA 4 enclosure (not shown).Hinged removabletop coverExternal, unitary plug-in terminal strips for field wiring connectionsON-OFF power switchGraphical backlit LCDAluminum NEMA1 enclosure Cover mountedmembrane keypadFAN -E AIRFLOW MEASURING STATION.Multi-point, self-averaging, Pitot traverse station with integral air straightener-equalizer honeycomb cell. Capable of continuously measuring fan discharges or ducted airflow with an accuracy of 2% or better.AMCA CERTIFIED in accordance with Standard 610 for airflow measurement station performance.VOLU -PROBE /1, 2, 3, 4 AIRFLOW TRAVERSE PROBES & STATIONS.Multi-point, self-averaging, Pitot Fechheimer airflow traverse probes and stations with integral airflow direction correcting design ensures accurate measurement. Various mounting configurations to fit every application.AMCA CERTIFIED in accordance with Standard 610 for airflow measurement station performance.VOLU -PROBE/FI FAN INLET AIRFLOW PROBES.Multi-point, self-averaging, Pitot Fechheimer airflow probes with integral airflow direction correcting design.For mounting directly in the inlet cones or bellmouth of centrifugal or vane-axial fans to measure fan capacities within 3% of actual flow.S.A.P . /B, P , S, R STATIC PRESSURE SENSORS.Available in four separate mounting configurations, the S.A.P. family of static pressure sensors generate a steady, non-pulsating output of room, space or plenum pressure.S.A.P. sensors are available in aluminum or stainless steel construction.VOLU -flo /OAM OUTSIDE AIR MONITOR.Monitor/Controller designed to accurately measure outside air to assist in meeting air ventilation requirements of ASHRAE 62-99. Capable of accurate measurement throughout flow turndown range of 16:1 and unaffected by rain, wind, and airborne debris. Optional measurement station provides simpleinstallation and commissioning.P.O. Box 6358 • Santa Rosa, CA 95406 • P: 800-airflow • F: 707-526-9970•***********************125-550 (7/07)Web (11/18)VOLU-probe/SS STAINLESS STEEL AIRFLOW TRAVERSE PROBES.Multi-point, self-averaging, Pitot-Fechheimer airflow traverse probes with integral airflow direction correcting design. Constructed of type 316 stainless steel and available in externally and internally mounted versions for harsh, corrosive or high temperature applications such as fume hood, laboratory exhaust, pharmaceutical,and clean room production and dirty industrial process applications.Precision Airflow MeasurementAn ON I CON Brand。

【优质文档】声级计2250使用说明书-word范文模板 (8页)

【优质文档】声级计2250使用说明书-word范文模板 (8页)

本文部分内容来自网络整理,本司不为其真实性负责,如有异议或侵权请及时联系,本司将立即删除!== 本文为word格式,下载后可方便编辑和修改! ==声级计2250使用说明书篇一:多功能声级计使用说明书多功能声级计使用说明书一、原理二、仪器简介三、使用方法四、使用过程五、注意事项一、原理从正弦信号发生器产生一定频率的正弦信号,经过扬声器发出声音,用声级计测量该声音的声级。

二、声级计简介三、使用方法1、用声校准器检查声级计的校准情况(可忽略)2、根据被测声音的大小将量程开关置于合适的档位,如无法估计大小,则置于“85—130”3、将时间计权开关置于标准所规定的位置;声级比较稳定时,置于“F”(快);声级变化剧烈,则置于“S”(慢)4、将读数标志开关置于“5S”或“3S”5、将电源开关置于“开”;仪器开始工作时显示数字6、如果显示器右端显示出过量标志“▲”(可欠量标志“▼”),此时应将量程开关向上“或向下”移动,使量程标志消失。

如果量程标志无法消失,则表时被测声级超出了仪器的测量范围。

7、调整好声级计的量程后,即可从显示屏上读取测量结果。

8、作好测量记录9、测量完毕后,建议再用声校准器检查声级计的灵敏度,以确保测量数据的准确可靠。

10、将电源开关置于“关”。

如较长时间不再使用此仪器,务必将电池取出。

四、使用过程本活动主要是通过声级计的使用,不同固定噪声源的设点、测量、数据整理和统计,学习噪声的测量及评价环境噪声的方法。

1.对照声级计使用说明书,熟悉声级计的使用方法和操作步骤。

2.根据测试者的要求,在校园内教学楼、学校围墙四周等有固定噪声源处设立测试点,记录当时的天气情况。

3.将声级计对准噪声源,保持声级计离地1.2米、距噪声源1米,每隔5秒钟读取一个瞬时分贝数,共读取l00个数据,作好记录(表3-4-1-l)。

4.整理数据,求出累计百分声级数Lp,10、Lp,50、Lp,90和等效连续声级Lp,eq。

五、注意事项1、声级计使用电池供电,应检查电池电压是否满足要求:电表功能开关置"电池"档,"衰减器"可任意设置,此时电表上的指示应在额定的电池电压范围内,否则需要更换电池2、按声级计使用说明书规定的预热时间(例如10分钟)进行预热3、校准放大器增益:电表功能开关置"0"档,"衰减器"开关置"校准",此时电表指针应处在红线位置,否则需要调节灵敏度电位器4、在不知道被测声级有多大时,必须把"衰减器"放在最大衰减位置(例如120dB),然后在测量时逐渐调整到被测声级所需要的衰减档位置,防止被测声级超过量程打坏声级计篇二:AWA6228型多功能声级计使用说明书AWA6228型多功能声级计使用说明书目录1.概述 (6)2.主要特点 (6)3. 主要性能指标 (6)4.结构特征 (8)5.符号、缩写定义 (9)7.主要显示界面 (11)7.2 测量界面 (11)7.2.1 噪声测量界面 (12)7.2.1.1 单次测量界面 (12)7.2.1.2 24小时自动测量界面 (13)7.2.2 定位测量界面 (14)7.2.3 倍频程频谱分析界面 (15)7.2.3.1 OCT列表界面 (15)7.2.3.2 醒目界面 (15)7.2.3.3 图形界面 (16)7.2.3.4 室内界面 (16)7.2.4 机场噪声测量界面 (16)7.3 设置界面 (17)7.3.1 设置第1页 (17)7.3.2 设置第2页 (18)7.3.3 设置第3页 (18)7.4 调阅界面 (19)7.5 校准界面 (19)8.使用方法 (20)8.1 参数设置 (20)8.1.1 日历时钟调整 (20)8.1.2 测量时间设置 (20)8.1.3组名(测点名称)输入及选择 (20)8.1.4 组名的查看 (21)8.1.5 统计用频率计权的选择 (22)8.1.6 LCD显示对比度调节 (22)8.1.7 SMS设置 (22)8.2 噪声单次测量 (22)8.3 24小时自动监测 (23)8.4 噪声频谱分析 (23)8.5 机场噪声测量 (23)8.6 数据调阅 (23)8.6.1单次测量结果的调阅 (23)8.6.2 24小时自动监测结果的调阅 (24)8.6.3 OCT分析结果的调阅 (24)8.7 数据打印 (24)8.7.1 单次测量结果的单组打印 (25)8.7.2 单次测量结果的多组打印 (25)8.7.3 24小时测量结果打印 (25)8.7.4 统计、累积分布图打印 (27)8.8 校准 (27)8.8.1 采用AWA6221(B)进行声校准 (27)8.8.2 用活塞发声器进行校准 (27)8.8.3 直接输入灵敏度级 (27)8.9 GPS定位测量 (27)9 SD卡大容量存贮功能 (28)9.1 大容量数据存贮 (28)9.1.1 开机自检 (28)9.1.2 数据调阅及打印 (28)9.1.3 数据记录 (29)9.2 录音及回放 (29)9.2.1 录音 (29)9.2.2 回放 (29)9.3 U盘功能 (29)9.4 其它注意事项 (30)10.测量范围及本机噪声修正 (30)11. 过载指示 (31)12. 1/3 OCT分析软件使用说明 (32)12.1 主要性能指标 (32)12.2 1/3倍频程分析界面 (32)12.2.1 1/3倍频程分析列表界面 (32)12.2.2 醒目界面 (33)12.2.3 图形界面 (33)12.3 自定义频率计权设置 (33)附录一:装箱清单(标准配置) (35)附录二:GPS定位系统简介 (36)附录三指向性响应 (37)附录四自由场响应 (38)附录六滤波器衰减特性 (40)篇三:数字声级计使用说明HSS5633型数字声级计使用说明书1 使用方法1.1 使用前准备1.1.1仔细阅读使用说明书,了解性能功能及注意事项。

银河电气 VSV152-G150T02-I 电压传感器使用说明书

银河电气 VSV152-G150T02-I 电压传感器使用说明书

VSV152-G150T02-I电压传感器使用说明书V1.01感谢您选用银河电气电压传感器本手册为湖南银河电气有限公司产品电压传感器用户手册,本手册为用户提供安装调试、操作使用及日常维护的有关注意事项,在安装、使用前请仔细阅读。

本手册随产品一起提供,请妥善保管、以备查阅和维护使用。

声明我们非常认真的整理此手册,但我们对本手册的内容不保证完全正确。

因为我们的产品一直在持续的改良及更新,故我方保留随时修改本手册的内容而不另行通知的权利。

同时我们对不正确使用本手册所包含内容而导致的直接、间接、有意、无意的损坏及隐患概不负责。

安全操作知识◆产品使用前,请您务必仔细阅读用户手册。

◆需对产品进行搬动时,请您务必先断电并将与之相连的所有连接线缆等拔掉。

◆如果发现机壳、稳固件、电源线、连接线缆,或相连的设备有任何损坏,请您立即将装置与电源断开。

◆如果对设备的安全运行存在疑虑,应立即关闭设备和相应附件,并在最快时间内与本公司技术支持部门取得联系,沟通解决。

1. 产品概述VSV152-G150T02-I是一种能在原边、副边完全隔离条件下测量直流、交流、脉冲以及各种不规则波形的电压传感器,它主要用于要求准确度高的计量检定和计量校准领域,以及要求高灵敏度、高稳定性和高可靠性的电能质量分析、功率分析仪、医疗、航空航天、导弹、舰艇等领域。

2. 技术特点⚫极高的准确度⚫极好的线性度⚫极高的稳定性⚫极高的灵敏度⚫极高的分辨率⚫极低的温度漂移⚫抗干扰能力强⚫响应速度快⚫极低的噪声⚫极小的角差⚫宽频带⚫模拟量输出3. 应用场合⚫计量检定与校准⚫实验室电压测量⚫仪器仪表(如功率分析仪)⚫医疗设备(如核磁共振MRI)⚫电池组检测⚫电力控制⚫电源⚫舰船⚫新能源⚫轨道交通⚫航空航天⚫工业测量4. 电气性能项目符号测试条件数值单位最小标称最大原边额定电压V PN-- -- 1500 -- Vrms 电压测试范围V PM-- -- -- 2000 V p 工作电压V c全范围-- ±15 -- Vdc 电流消耗I c V PM范围内-- ±80 -- mA 变比K N输入:输出2000:10 -- 额定输出V SN V PM输入--±10--V p 5. 精度-动态参数项目符号测试条件数值单位最小标称最大精度X e额定输入,25±10℃--0.1--% 线性度εL-- --100 --ppm 角差Δφ50Hz -- 0.0315 -- °零点失调电压Vo @25℃-- -- ±0.5 mV 零点失调电压VoT 全温度范围-- -- ±5 mV 频带宽度(- 3 dB) F -- 0 -- 200 kHz 6. 一般特性项目符号测试条件数值单位最小标称最大工作温度范围T A-- -10 -- +70 ℃存储温度范围T S-- -25 -- +85 ℃质量m --350±30 g7. 安全特性项目符号测试条件数值单位最小标称最大耐受电压原、副边之间副边与外壳之间V d DC -- 6 -- kV8. 外形尺寸及端口定义8.1、外形尺寸(单位:mm)图1 外形图8.2、端口定义⚫输出端为4P穿墙端子,输出端子定义为:+ :+ Vcc- :- VccG:公共接地端M:测量信号输出端⚫ 被测量电压输入端为2星接线柱,输入端子定义为:+ :接被测量电压高端 - :接被测量电压低端9. 应用连接及说明-++:接+VCC -:接-VCC-+G :公共接地端被测电压+TH-THM :测量输出端VG图2 电气连接图测量说明:通过测量输出两端的压降U s ,根据下式可以得到原边被测电压V P :V P = K N *U s10. 包装清单 序号名称型号及规格数量备注1 电压传感器 VSV152-G150T02-I 1件 2使用说明书VSV152-G150T02-I1份11. 注意事项⚫ 此模块为标准传感器,对于特殊的应用与要求请与我们联系。

炜盛电子 GM-502B MEMS VOC气体传感器说明书

炜盛电子 GM-502B MEMS VOC气体传感器说明书

MEMS VOC气体传感器(型号:GM-502B)使用说明书版本号:1.1实施日期:2017.05.10郑州炜盛电子科技有限公司Zhengzhou Winsen Electronic Technology Co., Ltd声明本说明书版权属郑州炜盛电子科技有限公司(以下称本公司)所有,未经书面许可,本说明书任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段进行传播。

感谢您使用炜盛科技的系列产品。

为使您更好地使用本公司产品,减少因使用不当造成的产品故障,使用前请务必仔细阅读本说明书并按照所建议的使用方法进行使用。

如果您不依照本说明书使用或擅自去除、拆解、更换传感器内部组件,本公司不承担由此造成的任何损失。

您所购买产品的颜色、款式及尺寸以实物为准。

本公司秉承科技进步的理念,不断致力于产品改进和技术创新。

因此,本公司保留任何产品改进而不预先通知的权力。

使用本说明书时,请确认其属于有效版本。

同时,本公司鼓励使用者根据其使用情况,探讨本产品更优化的使用方法。

请妥善保管本说明书,以便在您日后需要时能及时查阅并获得帮助。

郑州炜盛电子科技有限公司GM-502B VOC气体传感器产品描述MEMS VOC气体传感器利用MEMS工艺在Si基衬底上制作微热板,所使用的气敏材料是在清洁空气中电导率较低的金属氧化物半导体材料。

当传感器所处存在气体环境中时,传感器的电导率随空气中被检测气体的浓度而发生改变。

该气体的浓度越高,传感器的电导率就越高。

使用简单的电路即可将电导率的变化转换为与该气体浓度相对应的输出信号。

传感器特点本品采用MEMS工艺,结构坚固,抗震性好;具有尺寸小、功耗低、灵敏度高、响应恢复快、驱动电路简单、稳定性好、寿命长等优点。

主要应用适用于室内空气质量监测、手机、电脑等消费类电子产品应用检测空气质量;也适用于呼出气体检测仪、室内烟雾报警等。

技术指标表1产品型号GM-502B产品类型MEMS VOC气体传感器标准封装陶瓷封装检测气体乙醇、甲醛、甲苯等检测浓度1~500ppm标准电路条件回路电压V C≤24V DC加热电压V H 2.5V±0.1V AC or DC 负载电阻R L 可调标准测试条件下气敏元件特性加热电阻R H 80Ω±20Ω(室温)加热功耗P H ≤50mW敏感体电阻R S1KΩ~30KΩ(in 50ppm乙醇) 灵敏度S R0(in air)/Rs(in 50ppm乙醇)≥3.0 浓度斜率α≤0.9(R200ppm/R50ppm乙醇)标准测试条件温度、湿度20℃±2℃;55%±5%RH 标准测试电路V H:2.5V±0.1V;V C:5.0V±0.1V传感器结构示意图基本电路图2 GM-502B 测试电路VcV H+2.5V引脚 连接 ① R H1 ② ③ R H2 ④ ⑤ R S1 ⑥ ⑦ R S2 ⑧图1 传感器结构示意图说明:上图为GM-502B传感器的基本测试电路。

WSD-2数字声波仪说明书

WSD-2数字声波仪说明书

目录一、熟悉您的仪器 (2)介绍仪器的特点和主要功能、技术指标,仪器的面板功能和充电器的使用。

仪器的成套性、测量前的准备、仪器的维护以及注意事项。

二、设置工作参数 (6)光电旋钮的作用和使用方法,菜单的一般操作规则。

[系统参数]和[测量参数]的输入以及输入范围,各参数输入的系统默认单位和一些系统约定。

三、数据采集、调节、读数和存盘 (9)介绍了仪器的各种触发方式,基线及门限的调节,怎样调节延时时间和采样间隔。

手动读数和存盘,以及零声时的测试方法。

四、波形处理 (13)对采集的波形怎样进行放大、收缩和拉伸,数字滤波和频谱分析,以及谱分析后的各种操作。

五、文件操作 (15)查看当前测试的记录,查看以前存储的文件和记录,以及回调文件中的记录。

怎样删除记录、文件和目录。

怎样打印数据和文件的转储与接收。

六、分析功能 (19)介绍了测桩、测强、浅裂缝、深裂缝、不密实、匀质性和测井等各种分析软件的操作,以及编程的依据,和一些野外的施工方法。

熟悉您的仪器仪器的主要特点WSD-2数字声波仪集电子技术、计算机技术、声发射与接收技术于一体,是高效、低功耗、稳定性高、便携的新一代智能化检测仪。

该仪器主要用于混凝土、岩体、陶瓷、石墨等非金属材料与结构的声波无损检测。

可检测混凝土构件的强度;结构内部缺陷;裂缝检测、结合质量与破损层厚度检测、匀质性检测、结构厚度检测、桩基质量检测以及材料弹性力学参数检测等。

□内置ALL-IN-ONE 控制级微机,与IBM商用计算机 100%兼容。

具有体积小、低功耗、抗干扰能力强、抗震性能好的特点,使该仪器能在环境恶劣的场地条件下正常工作。

□内置带背光的640×480大屏幕液晶显示器,即使在光线昏暗的环境或夜间,仍能让操作员正常观测波形和完成各种测量工作。

□内置32MB的大容量电子盘,可存上万个波形数据及测点记录数据。

这种电子盘不存在振动、冲击对其造成损伤;亦不存在掉电丢失数据的可能。

DKY―51―2型振弦式传感器记录仪使用说明书

DKY―51―2型振弦式传感器记录仪使用说明书

DKY―51―2型振弦式传感器记录仪使用说明书DKY―51―2型振弦式传感器记录仪是一种岩土原位监测仪器,它适用各类振弦式传感器采集频率信号,如孔隙水压力计、土压力盒、钢筋计、混凝土应变计,表面应变计等。

利用这些传感器可对尾矿坝、土工坝体、路基、桩载荷速率、测试桩承载力、摩擦力以及坝体浸润线安全监测提供可靠的原始测试数据。

本仪器采用当前国内外最新单片机技术,对弦式传感器(不论单双线圈)实现数据采集、信号处理、液晶显示。

仪器硬件集成化,设有很强的硬、软件抗干扰措施。

仪器抛掉了现有的各种钢弦频率仪传统的间接测量法,而采用直接测量法和计算机数字滤波新技术,使测试数据稳定可靠。

仪器还配有镍铬可充电池和充电器,适合无交流供电场合使用。

经过多年大量工程应用,并不断完善改进,到目前为止,该仪器稳定性能好,测试精度高,温度范围宽,操作十分简便,能满足用户在各种野外环境中使用。

⒈信号采集一路、液晶显示。

⒉测试精度± 1Hz。

⒊两组镍铬电池双 +9V。

⒋温度范围–100C — +600C。

⒌重量1.0Kg。

⒈接入传感器,打开电源启动开关,显示“0000”正常。

⒉按一下测试按钮,仪器显示传感器的频率值,如“1450”。

⒊测试下一个传感器步骤同1、2。

⒋测试结束,关断电源开关。

⒌仪器配有充电电池,一次充电可连续使用8小时,每次充电时间不应超过3小时。

⒍每次测试应重复一次,两次差值≤ 1Hz,说明测试结果正常。

⒎如测试结果不正常,应作下述检查:⑴传感器是否插好;⑵用万用表检查传感器是否开路(电阻值为无穷大),是否短路(电阻值为零);⑶如果⑴、⑵故障排除,则可能是传感器线圈进水,说明传感器已损坏。

⑴传感器标定传感器埋入前首先要进行严格的现场标定,现场标定值与厂家标定值之间相差±1Hz时,应进行数据表平移。

⑵现场安装钻孔过程中不应使用泥浆护孔,应使用套管护孔,以免泥浆挡住透水石,影响传感器正常工作。

成孔到设计深度后,先投入中砂2公分,再放入传感器,然后投入20公分中砂,再投入30公分黄泥球作隔水层,最后投入原孔土填实。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

YAV-Z2声音传感器(交流输出)技术手册
YAV Z2声音传感器(交流输出)
技术手册V1801
武汉亚为电子科技有限公司
YAV5152Z2
关于
序号版本号编写人编写日期支持对象应用时间特别说明1 1.0齐非2013.11YAV-Z12013.11
1 2.0郑冉2014.01YAV-Z12014.01
1 3.0朱健波2016.08YAV-Z12016.08
1 4.0朱健波2017.08YAV-Z12017.08
目录
0.快速上手 (1)
产品包装内容 (1)
接口定义 (1)
1.产品概述 (1)
技术指标 (2)
硬件特点 (2)
2.传感器的安装及固定 (3)
3.电压对应声压级表(非线性) (4)
4.性能测试 (5)
噪音波形 (5)
安全规范 (5)
环境适应性测试 (6)
5.注意事项及故障排除 (8)
注意事项 (8)
⏹存储说明 (8)
⏹出货清单 (8)
⏹质保及售后 (8)
⏹特别说明 (8)
故障排除 (8)
6.文档权利及免责声明 (10)
7.联系方式.........................................................................................................................错误!未定义书签。

8.V智能体验 (11)
0.快速上手
本章主要介绍初次使用YAV-Z2噪音传感器需要掌握的知识,以及与使用相关的准备工作,可以帮助用户熟悉YAV-Z2使用流程,快速上手。

产品包装内容
YA V-Z2噪音传感器、包装盒各一个,开发资料(官网下载)。

接口定义
端子定义说明:
●红色为电源正极
●绿色为电源负极
●黄色为信号线
1.产品概述
YAV-Z2噪声传感器具有声级计的全部功能,DC12V供电,并克服了传统手持式声级计信号输出复杂、感应不远的缺点,可采集声音波形信号。

十分方便的与PLC、PC、DCS等控制设备兼容而组成的精细噪声测量系统,特别适合集成于各种环境、产品监控设备,组成单点或多点噪声监控网络,是各类噪声源的噪声监控、检测、监测、实验的理想选择。

技术指标
输入输出功能指标
硬件特点
●能直接输出线性模拟量,AD采集更加方便解决了很多客户直接采集波形的痛苦,也可以直接作为
分贝传感器使用。

●可还原声音波形信号(采样率44.2khz,AD精度大于等于16位)
●电压与噪音成线性关系,具体可以根据噪音计校准。

●灵敏度高,店主亲测,在封闭环境中,正常说话10米内可以检测到。

●供电电压范围宽,本次设计的模块,电源范围可从5-15V。

2.传感器的安装及固定
●室内外安装
●简易万能固定夹
●定点噪声测试架
●需做防风防雨处理
3.电压对应声压级表(非线性)
●AI采集模块的精度必须大于等于16位,否则45分贝以下的测试不准确。

●AI采集模块的采样率需大于1Khz。

●以上表格中的电压为0.5s时间内的均值电压,1K采样率,也就是500个点的数据取均值。

分贝计
算的时一段时间内的声压量,瞬态值意义不大。

●具体每个传感器可以根据噪音计设置公式校准。

●输出仅仅为电压,不能为电流。

●换算公式:对照校准表,非线性,呈对数曲线。

可按上表分段处理,也可自行分段,例如在45-85
分贝区间内,可以简单的用线性公式kx+b,例如12V供电,b为45,k为30。

4.性能测试
噪音波形
以上是示波器测量结果,信号不可用普通万用表测量 安全规范
●安全性:通过GB4943标准测试;
●PCB制品精密度:测试符合GB/T14838-2008标准;
●温度:测试符合GB-T-7141-2008标准;
●EMC:测试符合IEC1000-4-2标准;
●EMI:测试符合IEC1000-4-4标准;
●具体测试过程详见亚为产品测试规范一览表。

亚为产品测试规范一览表
1YA V/QC-/研(C)-100-01电路板元件规范
2YA V/QC-/研(C)-100-02电路板焊接规范
3YA V/QC-/研(C)-100-03元件安装检验规范
4YA V/QC-/研(C)-100-04电路板高温老化检验规范
5YA V/QC-/研(C)-100-05电路板高低温循环检验规范
6YA V/QC-/研(C)-100-06电路板震动检验规范
7YA V/QC-/研(C)-100-07电源连接线进厂检验规范
8YA V/QC-/研(C)-100-08电磁兼容检验规范
环境适应性测试
环境适应性测试表
上图显示输出信号振荡幅值很小。

5.注意事项及故障排除
注意事项
⏹存储说明
●密封保存期:12个月(温度≤30℃,相对湿度≤60%)。

●烘烤:推荐使用充氮方式烘烤。

●烘烤返工要求:125±5℃,24小时。

●推荐储存条件:相对湿度≤50%环境下真空包装。

⏹出货清单
YA V-Z2噪音传感器、包装盒各一个,开发资料(自行下载)。

电源等耗材用户自备。

⏹质保及售后
收货7天内有质量问题包退换,一年内免费维修。

6*24小时技术服务。

⏹特别说明
公司为各种硬件产品提供全面高效的数据采集平台软件配套服务,并发布相应的安装程序,采用配套软件可以充分地发挥产品的使用性能,可靠地实现各种信号采集功能。

如有特殊功能需求,可联系我司定制上位机程序,此外我司提供特定硬件的上位机开发服务。

故障排除
电压跳动大:采样率不够,没有计算一段时间内的均值。

低分贝不准:AI精度不够。

和噪音计不一致:多找几种噪音计,对比一下,一个不具备说服力。

注意:分贝测试是一个非常复杂的难题,声音频率跨度大(20hz-20Khz),很难检波,再加上幅度变化范围非常大130-40=90dB,也就是10^9,理论上需要30位的AD采集,但这也是不现实的,太小的信号极易受到电路板热噪声的干扰,所以噪音测试系统,动辄几万到几十万元。

普通几十元手持噪音计,是不可能做到标称的那么大范围的。

6.文档权利及免责声明
本文档知识产权属于我司,Yav、Yavii、YV、e-yav、亚为科技、亚为测控、亚为电子、均为我司的有效识别标识,未经允许,任何单位或个人不得整体或部分复制、转载、引用该文档内容,转载、引用时必须标明出处。

本文档未授予任何知识产权许可,并未以明示或暗示,或以禁止发言或其他方式授予任何知识产权许可。

除在期产品的销售条款和条件声明的责任之外,我司概不承担任何明示或者暗示的担保,包括对产品的特定用途适用性,适销性或对任何专利权,版权或其他知识产权的侵权责任等均不作担保。

本手册中的图片和文字仅供参考,所有信息均以实物为准。

我司对产品规格、描述及软件做出修改,恕不另行通知。

本公司提供的程序,欢迎广大用户下载学习。

未经许可,不得直接或间接用于商业用途,若产生纠纷,其责任概由使用者承担。

使用本公司产品时,请先详细阅读说明书及手册,并严格按规范操作,如有疑问请联系亚为技术支持。

若因失误造成损失,其责任概由用户承担,与本公司无关。

以上信息最终解释权归武汉亚为电子科技有限公司所属。

7.V智能体验
亚为活动表。

相关文档
最新文档