厂家声明 .......................................................................................................................................... I 警 告 ..............................................................................................................II 运输损坏和运输不符索赔 ............................................................................................................III Ecotech仪器上使用的国际公认符号 .......................................................................................... IV 1.0 介绍Introduction .....................................................................................................................1 1.1 概述Description ................................................................................................................1 1.2 说明Specifications ........

臭氧NLO-1K用户操作说明书

臭氧NLO-1K用户操作说明书

新大陆NLO-1K臭氧发生器产品说明书注意:在安装使用NLO-1K型臭氧发生器之前,请相关人员详细阅读产品说明书内关于安全须知和操作方法的内容,避免造成设备的损坏及对人身健康产生不良影响。

※封面图片仅供参考,以实物为准目录1.产品描述 (4)1.1规格型号 (5)1.2产品参数 (5)1.3环境条件 (7)2.安全须知 (7)2.1 氧气安全 (8)2.2 臭氧安全 (9)2.3 电气安全 (9)2.4 压力气体 (10)3.工作原理与系统介绍 (10)3.1 臭氧产生 (10)3.2 电气模块 (13)3.3 冷却水模块 (14)4.运行前的准备 (14)4.1 用户提供的资源 (14)4.2 运行前的检查 (16)5.运行操作 (17)5.1通电前的要求 (17)5.2 冷却水调节 (17)5.3 气体的要求和调节 (17)5.4 系统开机步骤 (18)6.维护 (19)7.故障的检查与处理 (21)8.售后服务 (22)9.部件清单 (22)10.附录A--电气与控制 (23)附录B—臭氧系统工艺流程图 (25)在安装使用NLO-1K型臭氧发生器之前,请用户详细阅读产Array品说明书内关于使用、操作方法及安全方面的内容,避免造成设备的损坏及对人身安全产生不良的影响。

在使用臭氧发生器之前,应确保所有的安全运行条件得到满足。

详细内容请参考第2章安全须知。

臭氧设备运行前请首先调节气体压力和流量,气体稳定后启动臭氧发生器电源开关进入工作状态。

设备的运行操作必须由经过相关技术培训的专人负责。

设备的维修工作必须由厂方指定的专业人员进行。

在未经生产商允许的条件下对设备进行改动可能会影响产品的安全性。

由此所造成的后果生产商不承担责任。

1. 产品描述新大陆NLO-1K氧气源臭氧发生器采用介质阻挡放电技术(Dielectric Barrier Discharge,DBD)产生高浓度的臭氧气体。

产品可以广泛应用于以下领域:●饮用水消毒●游泳池消毒●污水处理●水族馆●工业废水●空气消毒●工业氧化●纸浆漂白●实验室研究使用者应对臭氧发生器产生臭氧气体的使用及安全负有全部Array责任。

臭氧发生器(JZCF-100g说明书)

臭氧发生器(JZCF-100g说明书)

目录一、主要用途二、设备安装及使用程序三、保养与维护四、主要技术参数五、故障处理★使用前请认真阅读本手册★须知保养重于维修主要用途JZCF-G-3-100g型臭氧发生器适用于洁净室作定时消毒灭菌和大消毒,完全可以替代紫外线灯照射和化学薰蒸大消毒,不必在洁净区增加任何设备,决无二次污染。

可广泛应用于电子、光学、制药、生物制品、化工、遗传基因工程等行业。

设备安装1、机器通常在通风、干燥、洁净及0℃<室温≤42℃,冷却水进水温度<35℃、压力0.1~0.15Mpa的条件下使用(特殊情况另行设计)。

机器水平放置在地面即可,但周围不应有易燃、易爆物品(如易燃气体等)。

2、警告!:为了人身安全,请安装三相插头电源线(火线、地线、零线)专线单独设置一个电源开关,不要与其它设备共同用启动电源。

单相电源电压220V±10%(超过此值务必加装稳压器,以免机器发生故障),同时机器接地要良好(接地电阻必须<4欧姆)。

3、按照要求切实接好进水、排水、气管。

臭氧出口应接耐臭氧管件(不锈钢或聚氯乙烯材质等)。

4、臭氧发生器装卸、搬运、安装时应避免较强的震动及较大角度的倾斜。

★注:切记地线一定要接!★臭氧是强氧化剂,由于在空气中应用浓度与对表面氧化要求相比还是很低的,不足以造成明显损害。

橡胶制品例外。

外接用户气源安装注意事项(1)、JZCF-G-3-150g以内,外接用户气源臭氧发生器安装必备条件:(2)、JZCF-G-3-150g以上,外接用户气源臭氧发生器安装必备条件:(3)、JZCF-G-3-300g以上(含300g),外接用户气源臭氧发生器安装必备条件:设备使用程序1、根据消毒灭菌要求,设置机器灭菌工作时间,该时间继电器一般设置为45-60分钟(用户可以参考灭菌检测结果设置时间)。

消毒时应关闭新风进口和回风排放阀门,使整个被消毒的洁净室空气通过净化系统风道形成内部循环,从而达到消毒目的。

2、打开冷却水进水口开关,务必使冷却水流出,并保证在正常开机时水流畅通。

车间用臭氧发生器安全操作及保养规程

车间用臭氧发生器安全操作及保养规程

车间用臭氧发生器安全操作及保养规程臭氧发生器是车间中常见的设备之一,用于清除空气中的有害气体和异味。

为了确保员工的人身安全和设备的正常运行,我们需要遵守以下操作和保养规程。

使用前的准备1.开始使用臭氧发生器前要仔细阅读使用说明书。

2.检查臭氧发生器的电源,确认电源电压与设备标签上的电压一致。

3.检查设备是否安装稳定,无漏电、漏气和松动现象。

4.确认臭氧发生器所用的空气源干燥、清洁。

可以使用滤芯。

5.在操作臭氧发生器时需穿戴合适的防护装备,如呼吸面罩、手套等。

安全操作规程1.操作人员必须熟悉臭氧发生器操作程序。

2.严禁将手伸入臭氧发生器内部,并将任何物品放入臭氧发生器内部。

3.切勿私自拆卸、改装或调整臭氧发生器中的任何部件。

4.若在臭氧发生器操作过程中出现异常响声或气味,请立即停止使用并与维修人员联系。

5.要在室外安装集中通风系统,并配置应急报警装置。

6.确保臭氧发生器操作过程中设备安全,操作人员应随时监视设备运行状况。

7.在使用臭氧设备时不要让人员在周围待久,避免呼吸过多臭氧。

8.切勿将臭氧发生器长时间运行在高负载状态下,以保证设备的寿命和安全。

保养规程1.定时对臭氧发生器进行检查,避免机器出现问题。

2.定期清洁臭氧发生器,并检查设备表面是否有损坏或腐蚀。

3.定期更换滤网以保持设备的最佳工作状态。

4.注意及时更换设备的部件,延长设备寿命。

5.停用臭氧发生器后,应在通风良好的环境下进行彻底清洁,关闭电源。

6.将臭氧发生器存放在干燥、通风、避光的地方。

7.对于长期未使用的臭氧发生器,必须进行彻底清洁并进行贮藏。

总结臭氧发生器是车间中不可或缺的设备,但在使用过程中应当严格注意操作安全和设备保养。

我们应该始终坚持规范操作,保持设备完好,以确保员工、设备安全和车间生产的顺利进行。

臭氧发生器说明书

臭氧发生器说明书

臭氧发生器说明书Ozone Generator Specification适用于CF-G-3-(5-45)KG系列有限公司济南市臭氧应用工程技术研究中心臭氧发生器操作手册前言前言本臭氧发生器手册中包含了重要的安全注意事项、操作说明,是整个臭氧设备操作手册中不可缺少的组成部分。

操作人员在运行系统前必须仔细阅读本手册中的全部内容。

本操作手册(后面简称手册)中包含了所有与 CF-G-3- 型号臭氧发生器相关的详细信息,以便使用者在各个环节都能安全的操作和维护臭氧发生器设备。

手册将从下列环节进行论述:1.安装/固定,调试2.运行3.故障检修/维修4.运输,储存;报废,拆除/处臵本臭氧发生器的操作手册的保存:1.放臵在离车间最近的便利位臵2.交给该车间的负责人员3.妥善保存直到该设备被弃用必须保证操作人员能随时取阅本操作手册手册组成:本操作手册的附录中包含了用于维护、故障检修及维修的额外信息,如:警报列表电路图数据记录表。

臭氧发生器操作手册目录目录1产品说明 (4)1.1概况 (4)1.2技术数据 (4)2 安全措施和规范 (7)2.1 警示标识信息 (7)2.2 安全规范原则 (8)2.3 安全措施及注意事项 (9)2.4 安全设备和监测设备 (10)2.5 组织人员 (10)2.6 相关联危险 (10)2.7 其它危险 (13)2.8 紧急应对措施 (14)2.9 指南,标准和规范 (14)3安装调试 (15)3.1 安装前准备 (15)3.2 安装 (15)3.3 调试前检查 (16)3.4 电气线路接线 (17)3.5臭氧放电室臭氧出气管道连接 (17)4臭氧发生器工作原理 (18)4.1臭氧 (18)4.2臭氧发生器工作原理 (18)4.3 应用领域 (19)4.4 使用前重要说明 (19)5系统运行 (21)5.1开机前准备 (21)4.2 开机步骤 (21)4.3 系统开关机 (21)4.4.控制面板操作说明 (22)6 技术支持与售后服务 (27)6.1 售后技术支持服务 (27)6.2 维护 (27)7 免责声明 (29)1产品说明1.1概况臭氧发生装臵是用于制取臭氧气体(O3)的装臵。

臭氧高级氧化设备操作说明

臭氧高级氧化设备操作说明

臭氧高级氧化设备操作说明一、设备概述臭氧高级氧化设备是一种利用臭氧气体进行高级氧化处理的设备,可应用于水、空气、废气、废水等多种领域。

臭氧气体具有很强的氧化性和杀菌作用,能够有效地去除污染物和异味。

本操作说明主要介绍设备的基本操作方法和注意事项,以确保其安全运行和良好的处理效果。

二、设备工作原理三、设备操作步骤1.开机准备:(1)确保设备已连接到电源,并检查电源是否正常;(2)打开设备主电源开关,待设备启动完成后,显示屏上会显示操作界面;(3)检查设备各个部位是否正常,如气体进口、出口接头、阀门等。

2.参数设置:(1)在显示屏上选择需要处理的介质类型,如水、空气、废气或废水,并根据需要设置相应的处理时间;(2)根据实际情况设置臭氧输出量,一般情况下可设置为中等输出量即可。

3.开始处理:(1)当所有参数设置完成后,按下“开始”按钮,设备开始工作;(2)设备将抽取所需的氧气和电力,通过电解臭氧发生器产生臭氧气体,并将其送入处理介质中;(3)监控设备运行状态,并根据需要进行必要的调整和处理。

四、注意事项1.设备使用过程中,应定期检查和维护设备的各个部位,确保其正常运行;2.操作人员在接触设备时应穿戴好相应的防护装备,避免直接接触臭氧气体对人体带来的伤害;3.设备在处理过程中,可能会产生臭氧浓度过高的情况,应确保处理现场通风良好,避免臭氧泄露;4.设备在处理不同介质时,应根据实际情况进行适当的调整,保证处理效果;5.在处理废水时,需要对产生的废液进行正确处理,避免对环境造成二次污染;6.设备运行过程中,如发生故障应及时停机检修,避免进一步损坏设备。

五、设备维护1.定期清洁设备内部,确保设备正常运行;2.对设备涉及到的电气元件进行定期检测,发现异常情况及时更换;3.电解臭氧发生器需定期进行清洗和维护,保持其正常工作;4.定期对设备进行维护保养,确保设备的长期稳定运行。

以上为臭氧高级氧化设备的操作说明,希望能帮助到您。

臭氧发生器消毒机安全操作及保养规程

臭氧发生器消毒机安全操作及保养规程

臭氧发生器消毒机安全操作及保养规程臭氧发生器消毒机是一种常用于医院、实验室、食品加工厂等场所的消毒设备。

在使用过程中,必须严格按照操作规程进行操作并进行日常保养,以确保设备的正常运行和消毒效果。

下面是臭氧发生器消毒机的安全操作及保养规程。

一、安全操作规程1. 设备操作前的准备工作在启动臭氧发生器消毒机之前,需要进行以下准备工作:•检查设备连接是否牢固。

•检查消毒机的电源插头是否正确插入插座。

•检查臭氧管路及其连接是否漏气。

•核对设备的输出功率和使用范围,确保符合要求。

2. 操作步骤根据设备使用说明书,正确操作臭氧发生器消毒机,包括以下步骤:•打开设备电源,设置操作参数。

•将臭氧管路连接到需要消毒的物体或空间。

•启动设备开始工作。

•在设备工作期间,应密切观察其运行状态,如有异常应及时停机排查,并在处理完问题后再重新启动设备。

•在设备运行结束后,应关闭电源,并根据设备使用说明书进行设备的保养工作。

3. 注意事项在使用臭氧发生器消毒机时,需要注意以下事项:•操作时应带防护手套,以避免暴露在臭氧下引起的皮肤刺激。

•如果需要消毒的物品或空间内有可能存在易燃物品,需要提前做好防范措施,以免造成火灾事故。

•长时间不使用的臭氧消毒机需要及时拆卸氧气、臭氧管路并存放在干燥通风的地方。

•在设备运行期间,应定期检测臭氧浓度,确保其值在安全范围内,防止对人体造成伤害。

•操作人员应经过相关培训和考核,掌握正确的操作、维护和保养技能,充分了解设备的实质参数、限制条件和注意事项,以保证运行安全。

二、设备保养规程臭氧发生器消毒机是一种高潮解氧化设备,其内部结构复杂,需要定期进行清洁和维护,以确保设备长期稳定运行。

以下是设备保养规程:1. 日常保养•在使用后,应定期对设备清洗消毒,防止交叉感染。

•定期检查臭氧发生器消毒机内部管路结构是否有破损或者堵塞现象。

•定期检查消毒机的电气设备和传动部分圆周差距是否正常,并加油润滑。

•每次使用完成后清洗并通风。

2024年臭氧发生器系统安全操作流程(三篇)

2024年臭氧发生器系统安全操作流程(三篇)

2024年臭氧发生器系统安全操作流程1.将总电源柜内的各个设备电源闭合。

2.启动冷干机,观察冷媒表指示是否正常,运行5分钟后开启空压机,待压力达到0.4Mpa以上(储气罐底部手动排污阀每天手动排污23次)。

3.空压机运转正常后开启吸干机,观察压力变化(两个塔交换工作,每个塔工作5分钟,工作的塔压力与空压机的压力基本相同)。

4.调节补氮系统减压阀与氮气出气阀门,使流量保证1-2M3/h。

二.开启臭氧发生器气源系统1.将臭氧发生器电源柜内的电源闭合,将门面上的旋钮开关打到本地,门面上显示蓝、白灯亮。

2.点击手触屏上进气阀开关,由off转变on,气动阀打开,设备进入预吹状态。

3.观察臭氧发生器的压力和流量,压力保持在0.1Mpa左右,流量保持在60-100m3/h。

(看放电室上的压力表和流量计)此时气源系统开启完毕,设备进入预吹状态,(设备停机几小时,预吹1030分钟;设备停机3天以内预吹12小时;设备停机1周以上预吹45小时)4.将尾气分解器的电源闭合,然后开启尾气分解器。

(观察温度的变化)5.打开放电室冷却水机组。

三.开机1.待预吹结束后,点击手触屏的参数设置,点击臭氧开关至ON设备开机,进入预热状态,门上显示蓝.绿灯亮(预热时间为1030分钟)。

2.预热结束后点击功率设定设定功率(客户也可根据需要自行设定或不设),设备正常运转后,观察温度变化。

注意:设定功率时应阶梯式缓慢增加功率。

四.关机1.将功率设定设置为0,待功率降为20kw时,点击臭氧开关置OFF,设备停机,进入续吹状态(续吹时间为10分钟)。

2.续吹结束后,进气阀开关自动由ON转变为OFF,进气阀关闭(将门面上旋钮开关打到中间)。

3.依次关闭补氮系统的吸干机、冷干机、空压机。

4.关闭氧气源。

5.关闭尾气分解器。

6.关闭冷却水机组。

注意事项:1.工作压力保持在0.1Mpa左右,最高0.145Mpa报警最低0.06Mpa报警。

2.出气温度最高38度报警。

臭氧发生器使用说明书

臭氧发生器使用说明书

臭氧发生器使用说明书臭氧发生器使用说明书1、产品概述臭氧发生器是用于制取臭氧气体(O3)的装置。

臭氧易于分解无法储存,需现场制取现场使用,所以凡是能用到臭氧的场所均需使用臭氧发生器。

臭氧发生器在饮用水,污水,工业氧化,食品加工和保鲜,医药合成,空间灭菌等领域广泛应用。

臭氧发生器产生的臭氧气体可以直接利用,也可以通过混合装置和液体混合参与反应。

利用高压电离(或化学、光化学反应)等措施,使空气(或纯氧气源)中的氧气分解聚合为臭氧,臭氧形成的过程是氧的同素异形转变过程;亦可利用电解水法获得。

臭氧的不稳定性使其很难实现瓶装贮存,一般只能利用臭氧发生器现场生产,随产随用。

臭氧为混合气体,其浓度通常按质量比或体积比来表示。

质量比是指单位体积内混合气体中含有多少质量的臭氧,常用单位mg/L、mg/m3或g/m3等表示。

体积比是指单位体积内臭氧所占的体积含量或百分比含量,卫生行业常用ppm表示臭氧浓度,即每立方臭氧混合气体中臭氧占该体积的百万分之一为1ppm。

臭氧浓度是衡量臭氧发生器技术含量和性能的重要指标。

同等的工况条件下臭氧输出浓度越高其品质度就越高。

2、产品分类臭氧发生器分类方式有很多种,通常情况下有以下几种情况:1)按单位时间臭氧产量分类时,分大型、中型和小型。

大型臭氧发生器是指每小时臭氧产生量在1Kg以上的臭氧发生器,其主要应用范围是废水废气处理、城市供水、化工深度氧化等场所。

中型臭氧发生器是指每小时臭氧产量在100g-1000g范围内的臭氧发生器,其应用范围是食品加工、精细化工、制药行业。

小型臭氧是指每小时臭氧产量在10g-100g范围内的臭氧发生器,其主要应用范围是实验室、房间除味、瓜果蔬菜除农药残留等。

当然还有产量在1g以下的微型臭氧发生器,主要是家用。

2)按工作原理分类,臭氧发生器主要有三种:高压放电式、紫外线照射式、电解纯水式。

高压放电式臭氧发生器是利用交流高压电产生高压电场,使电场内或电场周围的氧分子发生电离,完成臭氧分子的合成过程。

臭氧发生器原理及基础知识说明书

臭氧发生器原理及基础知识说明书

臭氧发生器原理及根底知识说明书1.什么是臭氧臭氧,又名三原子氧,因其类似鱼腥味的臭味而得名。

其分子式为 O3,是氧气的同素异形体,具有它自身的独特性质:①在自然条件下,它是淡蓝色的气体;②它有一种类似雷电后的腥臭味;③在标准压力和常温下,它在水中的溶解度是氧气的 13 倍;④臭氧比空气重,是空气的 1.658 倍;⑤臭氧有很强的氧化力,是最强的氧化剂之一〔仅次于氟〕;⑥臭氧的密度是 2.14g·l(0°C,0.1MP)。

沸点是-111°C,熔点是-192°C,正常情况下,臭氧极不稳定,容易分解成氧气;⑦臭氧分子是逆磁性的,易结合一个电子成为负离子分子;⑧臭氧在空气中的半衰期一般为 20-50 分钟,随温度与湿度的增高而加快;⑨臭氧在水中半衰期约为 35 分钟随水质与水温的不同而异;⑩臭氧在冰中极为稳定,其半衰期为 2000 年。

2.臭氧的制取臭氧是一种不稳定的气体,不能储存运输,一般臭氧采用现场制作。

根据制取的工作原理和原料的不同,分类如表一:表一:臭氧制取方法分类产生方法工作原理原料应用围放电法放电电解〔ED〕空气或氧气实验室到实际工程电化学法电解高纯度水需要纯水的实验室和小型工程光化学法辐射〔吸收电子〕空气〔氧气〕饮用水或高纯水新技术,适用于实验室到实际工程辐射化学法X光,γ线高纯水不常用,仅用于实验热法光电弧电离水不常用,仅用于实验电晕放电合成臭氧是目前世界上应用最多的臭氧制取技术,此技术能够使臭氧产量单台达500kg/h以上。

它的主要分类如下:表二:电晕放电合成臭氧技术分类分类方式类别组成及特点构造板式〔亦称奥托托板式〕由平板式电机和介电体,仅用于少数小型臭氧发生器管式卧管式〔玻璃管式、外玻璃管式〕由特种玻璃管为介电体和不锈钢管作电极组成放电单元主要用在医院污水处理的臭氧发生器立管式〔水冷立管式、油水双立管式〕网格式〔劳泽板式〕瓷材料作介电体,采用高频电源,空气冷却,效率高电源工频电源〔50/60 Hz〕固定频率,电压可调中频电源〔400-600 Hz〕固定频率,电压可调高频电源〔>1000Hz〕频率可调,电压固定电晕放电技术中管式构造臭氧发生器是目前臭氧市场广泛采用、最为成熟的技术,占据我国大局部臭氧市场。

臭氧发生器使用操作规程(冠生园)

臭氧发生器使用操作规程(冠生园)
昆明冠生园食品有限公司
文件编号:JS/OS-EPD-001 版本号:A 修订号:A-0 页码: 共 3 页
设备操作规程汇编
标题 1、 目的
臭氧发生器使用操作规程
规范臭氧发生器的使用,保证消毒效果达到生产要求,特制订本规程。 2、 适应范围 适用于组合空调使用的臭氧发生器。 3、 职责 3.1 动力部负责按照规定开启、关闭臭氧发生器;负责设备的日常保养、维修工作。 3.2 生产部车间主任负责确认下班后车间空气相对湿度达标准; 3.3 品控部品控员负责检查车间空气湿度、臭氧发生器有无按照要求进行操作;化验员负责臭氧 杀菌效果的验证工作; 4、 操作程序 4.1 为了保证消毒灭菌效果,车间所有的门窗必须关闭,以确保臭氧在空间分布均匀,使整个消毒空 间的空气通过净化系统的风道形成内循环状态,从而达到对灭菌区空气、物体、设备及墙壁、 天花、地面的灭菌;同时还能杀灭空气净化过滤系统和循环系统霉菌及其它杂菌,达到真正理 想的消毒效果。 4.2 空气湿度对消毒效果的影响比较大,湿度越大,消毒效果越好,一般要求空气相对湿度大于 60%为佳。如遇干燥季节,用湿拖把拖地或在地面浇水保证空气相对湿度在 60%以上。 4.3 消毒设置的时间在工人下班以后开 1.5 小时或工人上班前提前 3 小时开 1.5 小时。 周一至周 五开启时间一般设定为 00:00,关闭时间为 01:00 ;周六至周日车间不生产不开启,如生产开 启时间同上(时间设定方式见德力西 KG316TQ 时控开关说明书) ;每次两组臭氧发生器必须同 时开启。 4.4 启动臭氧发生器设备前先启动净化空调。在四楼配电室将电源总开关打开,净化空调电源指
1/3
示灯黄灯亮,然后旋开红色的急停开关,净化空调的控制屏亮,按下控制面板的绿色运行 键,指示灯④亮-绿,净化空调风机正常运转并有风机运行的声响。如果要停止净化空调则按 下控制面板上红色的停止键即可停止空调运行,紧急状况下可按下急停开关关闭空调。 4.5 在净化空调风机正常运转的状态下,臭氧发生器的时控开关电源指示灯亮-绿,显示电源 电压,机器进入准备工作状态。 4.6 按时控开关”自动/手动“键将控制方式调整到自动,此时指示状态的三角箭头指在” 自动“位置,工作指示灯亮-红,定时器开始计时,电流显示工作电流机器已经正常工作, 机内有“吱吱”放电声并可见机内有闪烁跳跃的蓝色光电条带同时可嗅到一般所特有的鱼腥 的气味。 4.7 当到达所设定的时段后,定时器停止运行,机器自动停机,此时工作指示灯红灯灭。若需重 新设置工作时段,必须在机器停止工作的状态下才能重新调整定时器。 4.8 机器正常工作时,若需临时停止臭氧发生器,则按下停止按”自动/手动“按钮,工作指示灯红 灯灭即可,待停机 1 小时后方可进入,若急需进入应预先停机,并通风数分钟。 4.9 长期停机必须切断电源。 4.10 臭氧发生器在停机 30-60 分钟臭氧自行分解还原为氧气过程中仍有杀菌功效,因此,停机 后门窗继续关闭 1-2 小时效果更好。 4.11 化验员作空气采样培养也应在停机 60 分钟后无二次污染情况下进行,其结果更为真实准 确。 5、 注意事项 5.1 有人的状态下,严禁使用臭氧发生器。 5.2 维护保养时必须在无电的情况下进行。 6、 罚则 各部门人员未按照该规程操作的,处以 50-200 元罚款。 7、 应用表格

臭氧除甲醛的操作方法

臭氧除甲醛的操作方法

臭氧除甲醛的操作方法
要去除甲醛和其他污染物,可以考虑使用臭氧发生器。

操作方法如下:
1. 将臭氧发生器放置在待处理的空间中心位置,并确保空间内无人居住或工作。

2. 打开臭氧发生器电源,并按照使用说明书调整好臭氧发生器的工作模式和时间。

3. 关闭空间内的门窗,确保空间密封。

4. 开启臭氧发生器,让其工作一定时间(具体时间根据设备说明书调整),待臭氧分解甲醛和其他有害气体。

5. 关闭臭氧发生器,打开门窗通风,让空间内的臭氧气体释放到室外。

6. 可以重复以上步骤,直至达到理想的空气净化效果。

需要注意的是,在使用臭氧发生器时,应严格按照说明书操作,避免长时间暴露在臭氧中,以及确保没有人员在空间内工作或居住,以免对人体造成伤害。

臭氧发生器(JZCF-100g说明书)

臭氧发生器(JZCF-100g说明书)

目录一、主要用途二、设备安装及使用程序三、保养与维护四、主要技术参数五、故障处理★使用前请认真阅读本手册★须知保养重于维修主要用途JZCF-G-3-100g型臭氧发生器适用于洁净室作定时消毒灭菌和大消毒,完全可以替代紫外线灯照射和化学薰蒸大消毒,不必在洁净区增加任何设备,决无二次污染。

可广泛应用于电子、光学、制药、生物制品、化工、遗传基因工程等行业。

设备安装1、机器通常在通风、干燥、洁净及0℃<室温≤42℃,冷却水进水温度<35℃、压力0.1~0.15Mpa的条件下使用(特殊情况另行设计)。

机器水平放置在地面即可,但周围不应有易燃、易爆物品(如易燃气体等)。

2、警告!:为了人身安全,请安装三相插头电源线(火线、地线、零线)专线单独设置一个电源开关,不要与其它设备共同用启动电源。

单相电源电压220V±10%(超过此值务必加装稳压器,以免机器发生故障),同时机器接地要良好(接地电阻必须<4欧姆)。

3、按照要求切实接好进水、排水、气管。

臭氧出口应接耐臭氧管件(不锈钢或聚氯乙烯材质等)。

4、臭氧发生器装卸、搬运、安装时应避免较强的震动及较大角度的倾斜。

★注:切记地线一定要接!★臭氧是强氧化剂,由于在空气中应用浓度与对表面氧化要求相比还是很低的,不足以造成明显损害。

橡胶制品例外。

外接用户气源安装注意事项(1)、JZCF-G-3-150g以内,外接用户气源臭氧发生器安装必备条件:(2)、JZCF-G-3-150g以上,外接用户气源臭氧发生器安装必备条件:(3)、JZCF-G-3-300g以上(含300g),外接用户气源臭氧发生器安装必备条件:设备使用程序1、根据消毒灭菌要求,设置机器灭菌工作时间,该时间继电器一般设置为45-60分钟(用户可以参考灭菌检测结果设置时间)。

消毒时应关闭新风进口和回风排放阀门,使整个被消毒的洁净室空气通过净化系统风道形成内部循环,从而达到消毒目的。

2、打开冷却水进水口开关,务必使冷却水流出,并保证在正常开机时水流畅通。

臭氧发生器安全数据说明书

臭氧发生器安全数据说明书

SAFETY DATA SHEET for OZONE(Formerly MSDS)1.PRODUCT IDENTIFICATIONProduct Name: OzoneCommon Names/Synonyms: Triatomic Oxygen, Trioxygen, O3Ozone Generator Manufacturer/SupplierOzone Solutions, Inc. website: 451 Black Forest Rd. email: ***********************Hull, IA 51239712-439-6880Product Use: This SDS is limited to ozone produced in gaseous form on site by an ozone generator, in varying concentrations in either air or aqueous solution, for the purposes of odor abatement, oxidation of organic compounds, or antimicrobial intervention, in a variety of applications, from food processing to ground water remediation.2.HAZARD IDENTIFICATIONGHS Classifications:Physical Hazards Health Hazards Environmental Hazards Oxidizing Gas Skin Irritation – Category 3 Acute Aquatic Toxicity– Category IEye Irritation – Category 2BRespiratory Systemic Toxicity – Category 1(Acute & Repeated Exposures)NOTE: Severe respiratory toxicity will develop before skin or eye irritation go beyond listed categories. Anyone with chronic pulmonary problems, especially asthma, should avoid exposure to ozone.WHMIS Classifications (Workplace Hazardous Materials Information System, Canada)D1A Acute lethality – Very toxic, immediately C OxidizingD2A Chronic Toxicity –Very Toxic F Dangerously ReactiveD2B Mutagenicity – ToxicSignal word (GHS-US) DangerHazard statements (GHS-US) H270 - May cause or intensify fire; oxidizerH320 - Causes eye irritationH370 - Causes damage to organsH372 - Causes damage to organs through prolonged or repeated exposure H400 - Very toxic to aquatic life Precautionary statements P220 - Keep/Store away from clothing /…/combustible (GHS-US) materialsP244 - Keep reduction valves/valves and fittings free from oil and grease P260 - Do not breathe dust/fume/gas/mist/vapors/spray P264 - Wash ... thoroughly after handling P270 - Do not eat, drink or smoke when using this product P273 - Avoid release to the environment P305+P351+P338 - If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P307 + P311 - If exposed: Call a poison center/doctor P314 - Get medical advice/attention if you feel unwell P321 - Specific treatment (see ... on this label) P337+P313 - If eye irritation persists: Get medical advice/attention P370+P376 - In case of fire: Stop leak if safe to do so P391 - Collect spillage P403 - Store in a well-ventilated place P405 - Store locked up P501 - Dispose of contents/container to ... 3. COMPOSITION Chemical name Ozone Common names Triatomic oxygen, trioxygen Chemical Formula O 3 CAS Registry Number 10028-15-6 4. FIRST AID MEASURES Route of Entry Symptoms First Aid Skin Contact YES Irritation Rinse with water Skin Absorption NO NA NA Eye Contact YES Irritation Rinse with water, remove contacts Ingestion NO NA NA Inhalation YES Headache, cough, dry throat, heavy chest, shortness of breath Remove to fresh air, provide oxygen therapy as needed For severe cases, or when symptoms don’t improve, seek medical help.5. FIRE FIGHTING MEASURES While ozone itself is not flammable, it is a strong oxidant and may accelerate, even initiate, combustion, or cause explosions. Use whatever extinguishing agents are indicated for burning materials.6. ACCIDENTAL RELEASE MEASURES Turn off ozone generator, and ventilate the area. Evacuate the area until ozone levels subside.7. HANDLING AND STORAGE Ozone must be contained within ozone-resistant tubing and pipes from the generation point to the application point. Any leaks must be repaired before further use.8. EXPOSURE CONTROLS/PERSONAL PROTECTION OSHA Permissible Exposure Limit: 8 hour Time Weighted Average 0.1 ppm ANSI/ASTM: 8 hour TWA 0.1 ppm , Short Term Exposure Limit 0.3 ppm ACGIH: 8 hour TWA 0.1 ppm ; STEL 0.3 ppm NIOSH: Exposure Limit Ceiling Value 0.1 ppm light; 0.08 ppm moderate; 0.05 ppm , heavy; Light, moderate, heavy work TWA <= 2 hours, .2 ppm Immediately Dangerous to Life or Health 5 ppm Respiratory Protection : Use full face self-contained breathing apparatus for entering areas with high concentration of ozone. Engineering controls : use ozone destruct units (thermal and/or catalytic) for off gassing ozone.9. PHYSICAL AND CHEMICAL PROPERTIES Physical state Gas pH NA Molecular Weight 48.0 Flash point NA Appearance Clear at low concentrations, blue at higher concentrations Evaporation rate NA Odor Distinctive pungent odor Flammability NA Odor threshold 0.02 to 0.05 ppm; exposure desensitizes Explosive limits NA Melting point -193o C/-315o F Relative density NA Boiling point -112o C/-169o F Partition coefficient NA Vapor pressure > 1 atm Auto-ignition temperature NA Vapor density 1.6 (air = 1) Decomposition temperature NA Solubility in water 570 mg/L @20o C, 100% O 3; 0.64 @0o C (vol/vol) Viscosity NA 10. STABILITY AND REACTIVITY Ozone is highly unstable and highly reactive. Avoid contact with oxidizable substances, including alkenes, benzene and other aromatic compounds, rubber, dicyanogen, bromine diethylether, dintrogen tetroxide, nitrogen trichloride, hydrogen bromide, and tetraluorohydrazine. Ozone will readily react and spontaneously decompose under normal ambient temperatures.11.TOXICOLOGICAL INFORMATIONLikely routes of exposure: inhalation, eyes, skin exposure.Effects of Acute Exposure: Discomfort, including headache, coughing, dry throat, shortness of breath, heavy feeling in chest (including possible pulmonary edema/fluid in the lungs);higher levels of exposure intensify symptoms. Irritation of skin and/or eyes is also possible. Effects of Chronic Exposure: Similar to acute exposure effects, with possible development of chronic breathing disorders, including asthma.Inhalation LC50: mice, 12.6 ppm for 3 hours; hamsters, 35.5 ppm for 3 hoursIrritancy of Ozone YESSensitization to Ozone NOCarcinogenicity (NTP, IARC, OSHA) NOReproductive Toxicity Not ProvenTeratogenicity Not ProvenMutagenicity Not ProvenToxicologically Synergistic Products Increase susceptibility to allergens, pathogens, irritants12.ECOLOGICAL INFORMATIONThe immediate surrounding area may be adversely affected by an ozone release, particularly plant life. Discharge of ozone in water solution would also be harmful to any aquatic life. Due to natural decomposition, bioaccumulation will not occur, and the area affected would be limited.13.DISPOSAL CONSIDERATIONSOff-gassing of ozone should be through an ozone destruct unit which uses heat and/or a catalyst to accomplish the breakdown of ozone to oxygen before release into the atmosphere.14.TRANSPORT INFORMATIONNOT APPLICABLE, as ozone is unstable and either reacts with other substances in the environment or decomposes, and therefore must be generated at the location and time of use.15.REGULATORY INFORMATIONSARA = Superfund Amendments and Renewal ActSARA Title III Section 302 Extremely Hazardous Substance TPQ: 100 lbs.SARA Title III Section 304, EHS RQ: 100 lbs.SARA Title III Section 313: Ozone is reportable if more than 10,000 lbs. are used/year.TPQ (Threshold Planning Quantity) requires emergency planning activities if this amount is on site at any time during yearRQ (Reportable Quantity) requires any release of this amount into the environment to be reported to the National Response CenterSource: EPA List of Lists16.OTHER INFORMATIONThe half-life of ozone is much shorter in water than in air. Increased temperature in either solvent decreases the half-life. Published research indicates a half-life of 20 minutes for ozone dissolved in water at 20o C, and a half-life of approximately 25 hours for ozone in dry air at 24o C (McClurkin & Maier, 2010). The practical half-life time is actually less, especially in air, due to air circulation, humidity, the presence of contaminants or walls with which to react, etc. In many situations, with air movement, warmer temperatures, and normal relative humidity, the half-life of ozone in air could be 1 hour or less. Further, ventilation of a closed space to other areas will also disperse the ozone, so that concentration levels can rapidly decrease after generation ceases. Source websites:Canadian Centre for Occupational Health and Safety: Chemical Profiles: Ozoneohs.ca/oshanswers/chemicals/chem_profiles/ozone/Haz-Map: Occupational Exposure to Hazardous Agents: Ozone/category-details?id=68&table=copytblagentsInternational Chemical Safety Cards #0068: Ozone/niosh/ipcsneng/neng0068.htmlNIOSH Pocket Guide to Chemical Hazards: Ozone /niosh/npg/npgd0476.html United States National Library of Medicine ChemIDplus Lite: Ozone 10028-15-6 /chemidplus/ProxyServlet?objectHandle=DBMaint&actionHandle=de fault&nextPage=jsp/chemidlite/ResultScreen.jsp&TXTSUPERLISTID=0010028156 Preparer: Dave Kuiper, Ozone SolutionsDate of Preparation: 8/3/2016Disclaimer: Ozone Solutions provides this information in good faith, but makes no claim as to its comprehensiveness or accuracy. It is intended solely as a guide for the safe handling of the product by properly trained personnel, and makes no representations or warranties, express or implied, of the merchantability or fitness of the product for any purpose, and Ozone Solutions will not be responsible for any damages resulting from the use of, or reliance upon, this information.。

v111105型臭氧发生器说明书

v111105型臭氧发生器说明书

v111105型臭氧发生器说明书
键盘锁使用:长按[取消/恢复]键3秒以上可开启或解除键盘锁;若35秒内未按任何键,系统自动锁上键盘。

2.调校时钟:按住[时钟]键,同时按[时]、[分]键可调校时钟。

定时设置步骤如下:检查:连续按[定时]键检查每一组所设定的时间、星期是否正确。

3.修改:按[定时]键至需修改的定时组,按[取消/恢复]键消除当前设置,然后可按定时设置有关步骤重。

新设定该组开关时间(星期、时、分)。

4.手动控制:按[手动/自动]键可直接开、关电源,在“开”状态时,一直开;在“关”状态时,一直关;在“自动”状态时,自动执行已设定的时间程序。

5.在非“时钟显示”状态下,按[时钟]键或30秒未按任何键,保存当前设置可恢复到时钟显示状态。

6.如需日控循环,请务必将定时时间(开和关)均设置在星期全显状态。

臭氧发生器时控开关注意事项:
1.若显示屏上显示变弱时,请更换电池;若设定内容消失,需重新设定。

2.请勿自行修理、分解或改造本产品。

3.请勿使本产品沾染油或进水。

臭氧发生器说明书

臭氧发生器说明书

第一章节重要声明本使用资料着作权属广州佳环电器科技有限公司所有,未经本公司书面许可,任何单位或个人不得以任何方式摘录、复制或翻译,侵权必究。

广州佳环电器科技有限公司保留修改本说明书技术参数及规格的权力,对本说明书中的印刷错误及与最新资料不符之处我们会及时改进。

所有改动不再事先通知,但会编入新版使用说明中。

广州佳环电器科技有限公司保留对本说明书的最终解释权。

本使用说明书中的图示都是为了说明的需要而绘制的,可能会与真实新产品略有差别,这取决于技术改进的实际情况和新产品生产的具体时间,如果说明书所述内容与您的产品不符,请以产品为准。

注意事项请勿在高精度电子设备附近使用本产品,电波干扰可能引起高精度电子设备的误操作和其他问题。

尤其在以下设备附近需特别注意:助听器、起搏器和其他医疗电子设备、火灾探测器、其他精度自动控制装置。

不要拆卸或改装本产品,否则会造成本产品的损坏、漏电和电路故障。

避免过度受潮,水或其他液体进入本产品可能引起本产品漏电和故障。

避免用挥发性的溶液或有机溶剂擦拭设备,可能会损坏设备的表面。

合格的专用接地线,安全可靠的接地,使用的线路的容量是符合要求的,以确保消除火灾隐患。

设备安装人员必须经过培训才能开机维修。

使用臭氧时,严禁工作人员在高浓度臭氧空间环境中上班工作,工作人员在超过相关标准的臭氧浓度的空间环境中上班在应要有防护措施。

切记设备保养或维修时必须在断电和泄尽气压状态下进行,确保人员安全维修。

使用本产品的环境条件要求:1.1室内应无易燃易爆气体及导电粉尘。

禁止安装在氨气易泄露或有发生爆炸危险的危险区域室内有220V/50HZ交流电源。

部分臭氧设备同时需要用到380V/50Hz交流电源环境温度要求:-10℃-33℃环境湿度要求:≤55%。

放置本机的地面要求平整,注意将设备平稳放在地上或支架上。

设备安装时保持设备工作环境通风及空气干燥,该空间须安装排风扇或空调。

免费声明:对于超越我们责任能力范围的由自然灾害(如:地震、水灾等)或者任何行为和事故(包括在这些意外或其他异常情况下,用户故意或意外的滥用)而导致的损失,本公司不承担任何责任。

亚士图AstralPool-BWT 大型臭氧25-700克说明书

亚士图AstralPool-BWT 大型臭氧25-700克说明书

氧设备。
设备间通风 房间应保持充足的通风,因为再生时湿热的空气会进入房间,而装置需要
的是干冷的空气。 也可通过干触点使再生风机对房间进行通风。
卸车和运输 臭氧机柜是单独装箱发运的。卸车时须保持垂直。机柜门最小水平空间为
900mm,垂直空间为2300mm。 机柜应有起吊拉环,见图示。
空间要求 净高至少为2300mm。安装地点应平整干燥。 臭氧柜前应有1m的间距,确保容易进入。 臭氧柜背侧可靠近墙面。干燥器再生时释放的至少2000C的热空气从顶部泄
安全须知
当臭氧发生器运行时,高压部件带有高压电。 柜门打开时,高压电被自动切断。在接触高压部件前,它 附带的高压电必须通过接地释放掉。 臭氧是一种带有刺激性气味的气体。一旦发生泄漏,必须 立即按下门上即停开关关闭臭氧发生器。是用即停开关关闭臭氧发 生器时,柜体内的其它部件并未关闭。 使用本机时,请确保符合高压系统使用规范、符合EC臭氧 安全参数、符合水处理臭氧使用规范(GUV-R 1/474 of BG Gas Wasser)及臭氧事故预防规定。 设备安装间如发生臭氧泄漏到空气中,其产生的臭氧与空 气的混合体是有危险的。必须小心防止吸入臭氧。 臭氧在周边空气的MWC值是200微克/立方米(=0.1ppm,MWC= 工作间最大浓度。请参见:传单M052,“OZONE”ZH1/262,BG CHEMIE 出版。 可能遭受臭氧泄漏影响(故障引起) 的房间必须安装探测臭 氧浓度的声光报警系统,该系统被触发时就能自动切断臭氧制造。 标有“紧急停车”字样的按钮应位于通往臭氧室的所有出入口(门) 附近无危险的地方且便于操作。 参见“臭氧水处理指南GUV-R 1/474”,这些装置必须在设备 维护期间定期检查以确保功能正常。 干燥器再生时,高达200ºC的热空气(见技术参数)从设备 左侧和/或上部逸出。 不要在这些位置附近安装热敏感的设备和水管。

臭氧发生器使用说明书

臭氧发生器使用说明书

空气消毒(JY-CA)系列臭氧发生器适用于洁净室作定时消毒及物品物料消毒,完全可以替代紫外线照射和化学熏蒸大消毒,决无二次污染。

可广泛用于食品、保健品、化妆品、制药、生物制品、遗传基因工程等行业。

安装使用方法
JY-CA移动式臭氧发生器—在没有中央空调设备的情况下,设备直接放置在需要消毒的洁净厂房内进行运行,可不同时间内针对几个洁净车间进行消毒。

设备技术特点
1、臭氧发生器由SUS304不锈钢框架壳体、臭氧发生装置及专用配套高频高压电
源、电控配置、轴流式风机、万向轮(或底座)等几部分组成。

2、设备整体表面美观,稳定性好,可安全的应用于防爆环境中。

3、臭氧发生器核心部件采用沿面等离子体,复合陶瓷介质正极,合金材料覆盖,
负极纳米涂层等技术,臭氧产生量大,寿命长达10000小时以上。

4、采用先进的微电脑控制系统,可根据需要自行设定运行时间,操作简便,实
现无人值守。

5、设备采用机电气一体化技术,启动电压低,对环境无特殊要求。

6、臭氧发生元件拆卸方便,便于安装检修。

技术参数。