地暖清洗机说明书
清洗机操作手册说明书
31.Activate thesetting mode for signal volume•1 step, the Press and +1 step, Set to •Button signalsInformation signalsSet the 1 stepSet the volume**you may need toselect the function several times.2.Set thevolume for ...skippage 10Detergent for main wash,water softener, bleach, stain remover fabric softener, starchdoor handleService flap**If the active Additional functions and options buttons Press WashingCancelling the programmeProgrammes at high temperatures:–Cool washing:–Press Programme selector for switching the machine on and off and for selecting the programme. Can be turned in either direction.All buttons are sensitive and need only to be touched lightly.Press and hold the option button for an automatic run8consumption consumptionTake care not to trap items of laundry between the washing machine door and the rubber seal.Laundry with varying degrees of soilinglight SoakingPour soaking agent/detergent into compartment selector to Starching Starching is possible in all wash programmes if liquid starch is used. Pour starch into the partment in accordance with the manufacturer's instructions (rinse first if necessary).10Cleaning the detergent drawer ...... if it contains detergent or fabric softener residues.ʑʑThis should not be necessary if the correct detergent dosage has been used. If it is necessary, however, proceed according to the descaling agent manufacturer's instructions. Suitable descalers can be obtained via our website or model-dependentDisconnect the mains plug .No solvents.11Detergent solution pumpTurn the programme selector to Drainage hose at the siphonTurn the programme selector to 1.2.Filter in the water supplyProduct number Production numberTrust the manufacturer's competence. Turn to us.You will thereby ensure that the repairs are performed by trained service personnel equipped with original spare parts.en operating instructionsWashing machine WAS32471SNObserve the safety instructions on page 8.Read these instructions and the separate installation instructions before operating the washing machine.page 10Detergent for main wash, water softener, bleach, stain removerfabric softener, starch3door handleService flap**If the active Additional functions and options buttons Press WashingCancelling the programmeProgrammes at high temperatures:–Cool washing:–Press Programme selector for switching the machine on and off and for selecting the programme. Can be turned in either direction.All buttons are sensitive and need only to be touched lightly.Press and hold the option button for an automatic run1.Activate thesetting mode forsignal volume• 1 step, the Press and + 1 step,Set to •Button signals Information signalsSet the 1 step Set the volume**you may need toselect the functionseveral times.2.Set thevolume for ...skipLaundry with varying degrees of soilinglightSoakingPour soaking agent/detergent into compartmentselector toStarchingStarching is possible in all wash programmes if liquid starch is used. Pour starch into thepartment in accordance with the manufacturer's instructions (rinse first if necessary).810Cleaning the detergent drawer ...... if it contains detergent or fabric softener residues.ʑʑThis should not be necessary if the correct detergent dosage has been used. If it is necessary, however, proceed according to the descaling agent manufacturer's instructions. Suitable descalers can be obtained via our website or model-dependentDisconnect the mains plug .No solvents.11Detergent solution pumpTurn the programme selector to Drainage hose at the siphonTurn the programme selector to 1.2.Filter in the water supplyProduct number Production numberTrust the manufacturer's competence. Turn to us.You will thereby ensure that the repairs are performed by trained service personnel equipped with original spare parts.en operating instructionsObserve the safety instructions on page 8.Read these instructions and the separate installationinstructions before operating the washing machine.。
EX12 地毯清洁机使用说明书
Parts and Instruction ManualThis manual is furnished with each new MINUTEMAN EX 12 . This provides the necessary operating and preventive maintenance instructions. Operators must read and understand this manual before operat-ing or servicing this machine.This machine was designed to give you excellent performance and efficiency. For best results and minimal cost, please follow the general guidelines below:· Operate the machine with reasonable care.· Follow the manufacturers suggested maintenance instructions as provided in this booklet.· Use original Minuteman supplied parts.TECHNICAL SPECIFICATIONSModelEX 12 EX12H 121153 Stage 100 cfm100 psi N/A 12 gal.50’ (15m) 12-312” (30.5cm)5” (13cm)99 lbs (45kg)19” (48cm)30” (76cm)48” (122cm)Model No.Vac Motor Pump Heater Capacity Cord(s)Wheels Casters Weight Length Width Height12115H 3 Stage 100 cfm250 psi2000 watt - 210° Max Temp12 gal.(2) 50’ (15m) 12-312” (30.5cm)5” (13cm)118 lbs (53.5kg)19” (48cm)30” (76cm)48” (122cm)ContentsSafety Precautions (1)Grounding Instructions (1)Safety Labels (2)Electrical Requirements (2)Machine Components (2)Machine Set Up (3)Pre-Operation (3)Set Up (3)Operation (4)Draining Recovery Tank (4)Machine Maintenance (4)Daily Maintenance (4)Weekly Maintenance (4)Storing Machine (5)Troubleshooting (5)Exploded Views (7)EX12 - Base Assembly (7)EX12 - Solution Tank Assembly (8)EX12 - Recovery Tank Assembly (9)EX12 - Bill of Material (10)Minuteman International Made Simple Commercial Limited Warranty (15)4. Before leaving or servicing machine:-Turn off machine.-Unplug cord from wall outlet.5. When servicing machine:-Unplug cord from wall outlet.-Avoid moving parts.-Do not wear loose jackets, shirts, or sleeves.-Use manufacturer supplied or approved replacement parts. WARNING: Hazardous Voltage. Shock or electrocution can result. Always unplug machine before servicing.WARNING: Flammable materials cancause an explosion or fire. Do not use flammable materials in tank(s).WARNING: Flammable materials orreactive metals can cause an explosion or fire.Machine must be grounded. If it shouldmalfunction or breakdown, grounding provides a path of least resistance for electrical shock. This machine is equipped with a cord having anequipment-grounding conductor and grounding plug. The plug must be plugged into anappropriate outlet that is properly installed in accordance with all local code and ordinances.Do not remove ground pin; if missing, replace plug before use.Safety PrecautionsGrounding InstructionsThis machine is intended for commercial use. It isdesigned to clean carpet and upholstery in an indoorenvironment and is not constructed for any other use. Use only recommended cleaning solutions and accessory tools.All operators must read, understand and practice the following safety precautions.The following safety alerts symbols are used throughout this manual as indicated in their description:WARNING: To warn of hazards or unsafe practices which could result in severe personal injury or death.FOR SAFETY: To identify actions which must be followed for safe operation of equipment.The following information signal potentiallydangerous conditions to the operator or equipment:FOR SAFETY:1. Do not operate machine:-Unless trained and authorized.-Unless operator manual has been read and understood.-In flammable or explosive areas.-Unless cord is properly grounded.-With damaged cord or plug.-If not in proper operating condition.-In outdoor areas.-In standing water.-With the use of an extension cord.2. Before operating machine:-Make sure all safety devices are in place and operate properly.3. When using machine:-Do not run machine over cord.-Do not pull machine by plug or cord.-Do not pull cord around sharp edges or corners-Do not unplug by pulling on cord.-Do not stretch cord.-Do not handle plug with wet hands.-Keep cord away from heated surfaces.-Report machine damage or faulty operation immediately to your distributor.-Follow mixing and handlinginstructions on chemical containers.Safety LabelsElectrical RequirementsThe safety labels appear on the machine in various locations. Replace labels if they become damagedor cannot be read.WARNING: Flammable materials can cause an explosion or fire. Do not use flammablematerials in tank(s). Flammable materials or reactive metals can cause explosion or fire.ABCDMachine Set UpPre-Operation1. Vacuum carpet and remove other debris.2. Perform MACHINE SETUP procedures.3. Inspect power cord for damage.1. Carefully check carton for signs of damage. Report damage at once to freight carrier. The machine is shipped fully assembled and is ready for use.2. Open lid of solution tank. Fill solution tank with water or approved cleaning agent.WARNING: Flammable materials cancause an explosion or fire. Do not use flammable solutions or materials in tank(s).FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers.ATTENTION: If using powdered cleaning chemicals, mix prior to adding.3. Attach solution hose. (Located front of machine.)NOTE: Make sure the quickdisconnects snap together firmly. As you do this, always inspect hoses for cracks or fraying. Do not use if hoses are damaged.4. Attach other end of solution hose to wand.5. Attach vacuum hose to recovery tank.6. Plug machine’s cord into a grounded wall outlet.FOR SAFETY: Do not operate machine unless cord is properly grounded.FOR SAFETY: Do not operate machine with the use of an extension cord.Set Up7. Connect solution hose and make sure it is firmly secured.8. Turning machine on:A. Turn pump switch on.B. Pull up on wand lever to release air in the line. Hold lever until you have a steady flow of water coming out of the wand.C. Once pump is primed and you have pressure in the solution line, turn on heater switch(s) and wait a few minutes for water to heat up.NOTE: For best results leave pump and heater switch on for approximately 10 minutes before using as a pre-heat cycle.Also, the heater may be run in either 1000W or 2000W mode by rocking the switch up and down.D. Once water is heated, turn on vacuum motors and begin cleaning.To keep machine in good working condition, simply follow machine’s daily and weekly maintenance procedures.FOR SAFETY : When servicing machine, unplug cord from wall outlet.DAILY:1. Empty and rinse out solution tank thoroughly.2. Wipe off power cord and check for damage, replace if necessary. Coil cord neatly after use.3. Clean machine with an all purpose cleaner and damp cloth.(EVERY 20 HOURS OF OPERATION)1. Flush solution system with a system maintainer to dissolve normal chemical buildup.a. Pour 7.5L (2 gal) of hot water 60°C (140°F) into solution tank. Add system maintainer according to mixing instructions on bottle FOR SAFETY: When using machine,follow mixing and handling instructions on chemical containers.b. Operate machine for one minute.c. Shut off machine and allowremaining solution to break down chemical buildup overnight.d. Next day, spray out remaining solution and flush system with 11L (3gal) of clean water.2. Inspect vacuum hoses for holes and loose cuffs.3. Inspect spray pattern for clogging. If clogged, remove spray tips and soak them in arecommended liquid neutralizer for up to six hours. To remove spray tip, twist spray tip body counter-clockwise. Do not use pointed objects to unplug tips, damage will occur.4. Lubricate wheels with water resistant oil.5. Inspect machine for water leaks and loose hardware.6. Remove float shut-off screen from recovery tank and clean.WARNING: Flammable materials orreactive metals can cause an explosion or fire.Do not pick up.1. Work away from outlet and power cord to prevent cord damage.2. Use a recommended foam control solution in the recovery tank to prevent vacuum motor damage. Periodically check for excessive foam buildup in solution tank.3. To clean heavily soiled areas, repeat cleaning path from different direction.4. When ball float shuts off vacuum, it is time to empty the dirty water from the recovery tank, and refill solution tank.NOTE: When cleaning upholstery, always check cleaning instructions sewn in furniture by manufacturer5. After cleaning, relieve water pressure from tool before disconnecting hose. Squeeze trigger for five seconds after turning main power switch off.FOR SAFETY : When servicingmachine, unplug cord from wall outlet.1. Turn machine off and unplug power cord.2. Remove solution & vacuum hose3. Lift up drain valve lever to empty solution tank.OperationDraining Recovery TankMachine MaintenanceWeekly MaintenanceMaintenanceStoring MachineTroubleshooting1. Before storing machine, be certain to completely drainand rinse tanks of all water and solution.2. Drain and dry the vacuum hose as well, using the drain hose provided3. Store machine in a dry area in the upright position.4. Open recovery tank cover to promote air circulationSYMPTOM:UNIT WILL NOT TURN ON:PROBLEM:Not plugged in.SOLUTION:Plug machine in proper outlet.PROBLEM:Circuit breaker has popped.SOLUTION:Reset circuit breaker. Make sure no other items are running on the same circuit as machine. Outlet must be a 15-amp circuit.PROBLEM:Wire from power cord has become disconnected from terminal block.SOLUTION:Reattach wire to terminal block.SYMPTOM:PUMP IS NOT RUNNING PROPERLY:PROBLEM:Quick disconnects are not completely locked together.SOLUTION:Snap quick disconnects firmly together.PROBLEM:The solution tank is empty.SOLUTION:Fill the solution tank up with a premixed detergent.PROBLEM:Jet on upholstery tool is clogged.SOLUTION:Clean jet with soft wire brush or remove jet and flush clean.PROBLEM:Filters are clogged.SOLUTION:Remove filters and rinse clean with water.PROBLEM:Heater is blocked with hard water deposits.SOLUTION:Flush out heaters with system maintainers. If they are still blocked, replace heaters.PROBLEM:Brass check valve is stuck.SOLUTION:Replace with new check valve.PROBLEM:Pump wire has become disconnected.SOLUTION:Reconnect wire.PROBLEM:Switch on switch plate is bad.SOLUTION:Replace switch.PROBLEM:Pump motor brushes are worn out.SOLUTION:Replace pump.SYMPTOM:HEATER IS NOT WORKING PROPERLY:PROBLEM:The back up sensor, mounted on the heater has popped. SOLUTION:Reset sensor by pushing in button.PROBLEM:Heating element is bad.SOLUTION:Replace element.SYMPTOM:VACUUM MOTOR IS NOT WORKING PROPERLY: PROBLEM:Hose not connected tightly to upholstery tool or machine. SOLUTION:Connect hose tightly.PROBLEM:Drain valve is not shut completely.SOLUTION:Close drain valve completely.PROBLEM:Vacuum tank lid is not on tightly.SOLUTION:Secure the vacuum tank tightly.PROBLEM:Ball float is shut off.SOLUTION:Empty the vacuum tank of all wastewater.PROBLEM:Water is coming out of vacuum motor.SOLUTION:Use a low foaming detergent.PROBLEM:Floor wand or is clogged with hair, carpet fibers and or debris. SOLUTION:Clean floor wand.PROBLEM:Ball float is not installed correctly.SOLUTION:Make sure that ball float is firmly installed on the elbow.EX12 - Base AssemblyEX12 - Solution Tank AssemblyParts and Instruction Manual Page 8EX12 - Recovery Tank AssemblyParts and Instruction Manual Page 9Parts and Instruction ManualPage 10EX12 - Bill Of MaterialsI t e m P a r t N o .Q t y .D e s c r i p t i o n I t e m P a r t N o .Q t y .D e s c r i p t i o n 11210522 c a p , a x l e , 1/2" 401211552 b o l t , 1/4-20 x 1-1/4" h e x h e a d 21210592 w h e e l , 12" 411211192 B r a c k e t , L 070-036 31211676 w a s h e r , a x l e , c u t 1/2" i d 421212091 s o l t a n k , s p e e d s t e r 41210661 a x l e , 1/2" x 18-1/2", s p , b r e e z e 431210751 b r a c k e t , r e a r , f b /s p y 512116212 n u t , l o c k , 1/4-20, n y l o n i n s e r t 441211606 w a s h e r , 1/4" l o c k , s /s 612115716 w a s h e r , 1/4" f l a t , s /s 451210762 k n o b , t h u m b s c r e w , f o r b r a c k e t 71211758 b o l t , 1/4-20 x 1" h e x h e a d , s /s 461210181 e l b o w , b r a s s , 90 d e g , 3/8"m p t x 3/8" f m p t 81210732 c a s t e r , 5" 471211732 w a s h e r , 11/16"i d x 1-1/2"o d x .075, s /s 91212081 b a s e , s p e e d s t e r 481210201 n i p p l e , b r a s s , 3/8" x c l o s e 101210612 g u a r d , c o o l i n g f a n , w i r e 491210191 b u s h i n g , b r a s s , 1/2"m p t x 3/8" f p t , h e x 111212038 s c r e w , #10 x 5/8" h e x h e a d , z i n c 501210121 f i l t e r , s t r a i n e r , 1/2" 121211631 n u t , l o c k , 1/2" s t e e l 511210681 b r a c k e t , f r o n t h i n g e , s p /f b 131210531 f i t t i n g , s t r a i n r e l i e f , c o r d 521212022 b o l t , 1/4-20 x 1-1/2" h e x h e a d , s /s 141210321 p o w e r c o r d , e n d , 25', 14/3 g r e y 531210052 e l b o w , b r a s s , 90 d e g , 1/4"m p t x 1/4" f p t 151211812 b o l t , 1/4-20 x 3/4" s e r r a t e d h e x f l a n g e , z i n c 541211594 w a s h e r , 9/16"i d x 1"o d , f l a t , s /s 161211171 p l a t e , s i n g l e m a n i f o l d , 6.5" x 9" 551210081 n i p p l e , b r a s s , 1/4"m , h e x 171212111 m a n i f o l d , s i n g l e v a c 561211491 h o s e , 3/8" x 17-1/2", (O A L ), f x -f s w , s u r g e , 1600p s i 181211545 b o l t , 1/4-20 x 1/2" h e x h e a d , z i n c 571211772 w a s h e r , n y l o n , 9/16i d x 1-1/16o d x .031 191210381 g a s k e t , v a c u u m m o t o r 581210071 n i p p l e , b r a s s , 1/4" x c l o s e 201211253 v a c s u p p o r t , 3 s t a g e , 4-1/16" 591210101 a d a p t e r , b r a s s , e x t e n d e r , 1/4" m p t x 1/4" f p t , h e x 211211829 b o l t , 1/4-20 x 1/2" s e r r a t e d h e x f l a n g e , z i n c 601210041 q d , b r a s s , 1/4" f 221210211 v a c m o t o r , 3 s t a g e , 115V , t a n g e n t i a l 611210691 f l o a t , 2", b a l l s t y l e 231210421 e x h a u s t b o o t , p l a s t i s o l 621210771 e l b o w , 2" f l o a t 241211261 c u f f , 2" 631211351 p i p e , p v c , 2" 251211921 v a c h o s e , 2", w i r e r e i n f o r c e d 641211371 a d a p t o r , p v c 2, f m s l x f m t 261210512 c l a m p , h o s e , 2-1/4 D I A 651212002 g a s k e t , 2" i n l e t p o l y e t h y l e n e , 3" O D 2.35" I D 271211961 s o l h o s e , 1/4" x 24 1/2", (O A L ), f x f s w , 3000p s i 661210551 s p o u t , d r a i n , 45 d e g r e e 281210141 e l b o w , b r a s s , 90 d e g , 1/4" m p t x 1/4" m p t 671210541 v a l v e , d r a i n , 1-1/2" 291210061 b u s h i n g , b r a s s , 3/8"m p t x 1/4" 681212101 v a c t a n k , s p e e d s t e r 301210161 a d a p t e r , b r a s s , 1/2" b a r b x 3/8" f s w , b a l l e n d 691211382 i n l e t , 2" 311210171 e l b o w , b r a s s , 90 d e g , 1/2" b a r b x 3/8"m p t 701210722 w a s h e r , #8 f l a t , s /s 321210642 c l a m p , h o s e , 5/16-29/32 711211762 s c r e w , #10-32 x 1/2" S H C S , a l l o y 331211901 s o l h o s e , 1/2" k u r i 100p s i 721210631 p l a t e , s w i t c h , s p , 3 h o l e 341211694 n u t , k e p , #10-32 z i n c 731210282 s w i t c h , r o c k e r , 2 p o s i t i o n 351211644 s c r e w , #10-32 x 1-1/4" p h i l p a n h e a d , z i n c 741212171 g a s k e t , v a c l i d , 6.5" i .d 7.5" o .d 361210221 p u m p , 100p s i , d e m a n d , 115V 751210441 l i d , v a c t a n k , b l a c k , 7" 371211612 n u t , h e x , 1/4-20 s /s 761211746 s c r e w , #8 x 5/8 p h i l o v a l , s /s 381211584 w a s h e r , 1/4"i d x 1"o d , f l a t , s /s 771211141 g a s k e t , 2" i n l e t 391210414 w a s h e r , b u n a 1-1/8" o d x 3/16" i d 781211941e l b o w , i n l e t a s s e m b l y 2"B i l l O f M a t e r i a l - E X 12Minuteman International, Inc. warrants to the original purchaser/user that the product is free from defects in workmanship and materials under normal use. Minuteman will, at its option, repair or replace without charge, parts that fail under normal use and service when operated and maintained in accordance with the applicable operation and instruction manuals. All warranty claims must be submitted through and approved by factory authorized repair stations.This warranty does not apply to normal wear, or to items whose life is dependent on their use and care, such as belts, cords, switches, hoses, rubber parts, electrical motor components or adjustments. Parts not manufactured by Minuteman are covered by and subject to the warranties and/or guarantees of their manufacturers. Please contact Minuteman for procedures in warranty claims against these manufacturers.Special warning to purchaser -- Use of replacement filters and/or prefilters not manufactured by Minuteman or its designated licensees, will void all warranties expressed or implied. A potential health hazard exits without original equipment replacement.All warranted items become the sole property of Minuteman or its original manufacturer, whichever the case may be.Minuteman disclaims any implied warranty, including the warranty of merchantability and the warranty of fitness for a particular purpose. Minuteman assumes no responsibility for any special, incidental or consequential damages.This limited warranty is applicable only in the U.S.A. and Canada, and is extended only to the original user/purchaser of this product. Customers outside the U.S.A. and Canada should contact their local distributor for export warranty policies. Minuteman is not responsible for costs or repairs performed by persons other than those specifically authorized by Minuteman. This warranty does not apply to damage from transportation, alterations by unauthorized persons, misuse or abuse of the equipment, use of non-compatible chemicals, or damage to property, or loss of income due to malfunctions of the product.If a difficulty develops with this machine, you should contact the dealer from whom it was purchased.This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions and limitations may not apply to you.Cord Electric Group ………. Three years parts, two years labor, ninety days travel (Not to exceed two hours)Exceptions ………. Port-A-Scrub, one year parts, six months laborMPV 13, one year partsMPV 14 and 18, two years parts, one year labor RapidAir blower, one year parts, one year laborExplosion-Proof Vacuum, one year parts, one year labor Pneumatic Vacuums, three years parts, one year labor EX 12 and EX12H, one year parts, one year laborBattery Operated Group ….. Three years parts, two years labor, ninety days travel(Not to exceed two hours)Exceptions ……Sweepers, one year parts, one year labor, ninety days travel(Not to exceed two hours)Internal Combustion Group ….One year parts, one year labor, ninety day travel(Not to exceed two hours)Replacement Parts ……………..Ninety daysBatteries ………………………….0-3 months replacement, 4-12 months pro-rate Polypropylene Plastic Tanks …Ten years, no additional labor111 South Rohlwing Road · Addison, Illinois 60101 USA Phone 630- 627-6900 · Fax 630- 627-1130E-Mail, A Member of the Hako GroupMinuteman International Made Simple Commercial Limited Warranty985012REV A 06/07。
清洗机操作说明手册中文版
清洗机操作说明手册中文版一:清洗机的概述对于热处理零件,其表面的质量对热理质量会有一定的影响,零件表面越是清洁、无污垢,对热处理质量影响越小。
爱协林多用炉生产线中的清洗机正是为此目的而设计的。
清洗机的清洗可分前清洗与后清洗。
前清洗是零件在热处理前,为去除机加工过程残留的油污、铁屑,净化零件表面而进行的清洗过程;后清洗是零件在热处理后,为清除其表面未淋干的残油而进行的清洗过程。
二:清洗机的工作原理简介爱协林清洗机主要由喷淋室、水槽、升降台、油水分离器等几部分组成。
喷淋室内壁上布满了许多喷淋头,工作时,从喷淋头喷出高速水流再加上喷淋头的旋转从而达到净化零件表面的目的。
水槽又分清水槽与碱水槽,清水槽盛着的是自来水,用来清洗零件表面的碱液;碱水槽内盛着的是自来水和清洗液的混合物,用来清洗零件表面的油污、铁屑。
两个槽子的水温均由杆式恒温器来控制。
升降台在碱水槽和喷淋室之间上下运动,以达到碱水除残油和清水除残碱目的。
油水分离器安装在清洗机的后面,其作用是把碱水槽中碱水和油分离开,使碱水重新流回碱水槽,分离出来的油排入水沟。
清洗机的喷淋室和槽体上另外有控制补水和液位的检测系统,烘干系统、发泡系统、翻板机构等。
行走小车把清洗零件送入喷淋室,关闭炉门,启动程序后,升降台下降入碱水槽,开始碱水清洗。
这时发泡系统启动,靠它吹出的高压空气搅动碱液,使零件表面的油污脱离其表面浮在碱液表面上。
这些油污流入积油槽,通过油泵把它抽到油水分离器中进行油水分离后,分离的碱水依然流回碱水槽,油污则排入水沟。
碱水清洗结束后,升降台上升到淋水位,开始淋碱水。
淋碱水结束后,升降台上升到原始位置,这时清水喷淋泵启动,开始清水喷淋。
高速水流从喷头中喷出,将零件表面未淋干的碱液用清水清洗干净。
喷出的清水则通过翻板机构返回清水槽。
清水喷淋结束后,开始淋清水,烘干系统也同时启动。
通过洪干系统将零件表面的残水烘干。
当升降台回到原始位置,烘干启动后,补水监控系统也启动,这时它检测一下水槽中清水和碱水液位是否下降。
怎样用地暖清洗机清洗地暖的操作流程及注意事项
清洗前测堵—停暖时检测方法1、将排污管与污水缓冲器连接2、拆开进水堵头和回水堵头3、接上周波输出管接头和排污管接头4、将自来水连接管一端连接洗衣机水龙头,另一端连接进水堵头上的接头5、排污管连接回水堵头上的接头,关闭所有分路阀阀门6、打开水龙头,打开一路分路阀阀门,缓冲器有水流出,说明此路没有堵死7、再关闭测试好的分路阀,打开第二路依次进行测堵清洗前测堵—供暖时检测方法1、关闭进水总阀和回水总阀2、关闭所有分路阀阀门,打开泄压阀(排气阀)3、拆开回水堵头,接上排污管接头,接上排污管4、打开供热进水总阀,再打开一路分路阀阀门5、观察缓冲器是否有水流出,依次往下测试每路分路管连接清洗操作步骤如下:1、连接油水分离器连接管和油水分离器2、气动连接管连接油水分离器和机器供气入口3、连接自来水连接管:一端接洗衣机龙头,一端接机器供水入口4、连接脉冲管:一端接机器的脉波输出,一端接分水器上的进水堵头接口5、回水堵头接头连接排污管6、打开气泵供气阀门,供水端的水龙头,打开一路分路阀阀门7、机器连接24V电源,将档位调到遥控状态8、按遥控进行周波清洗9、清洗可以一路一路进行清洗,也可以打开多路同时清洗10、清洗结束,关闭水龙头,关闭气泵供气阀阀门11、待油水分离器上的压力指针归零后,关闭脉冲周波12、最后断开电源,解管备用系统清洗操作方法1、连接备用电源2、将供气管连接备用供气入口(其他连接管连接不变)3、按下备用开关按钮分路管连接清洗操作方法1、拆下一路分路管的进水口2、分路地暖管接上脉波输入管接头,再接上奶嘴接头3、分水器上进水端处接上15公分左右的软管4、软管另一端接上排污接头,再接上奶嘴接头5、连接好脉波输出管和排污管6、清洗可以一路一路进行清洗,也可以同时打开多路同时清洗供水口三角阀处连接方法1、若家里没有洗衣机龙头,也可在三角阀处拆开连接清洗2、关闭三角阀,拆开软管3、接上洗衣机龙头的奶嘴接头,连接自来水连接管(其他连接方式不变)注意事项1、压缩机工作时机体温度较高,不要触摸机头,防止烫伤身体;2、各连接部位一定拧紧,防止泄漏;3、排污端一定插入下水道口内,防止排污时污染环境;4、压缩机工作有异常声音时请立即切断电源停机检查;5、脉波发生器如有气、水泄漏请立即停止工作,马上和当地经销商或公司联系进行维修或更换;6、必需等气压表指示针归零,方可拆解供气管;7、清洗主机使用后必需把机器管道中的余水倒出,防止结冰,影响使用;8、带加热除湿款的,请在冻管或受潮时接通电源加热,正常时请勿用,如果机子内爆管,不能接通电源;操作过程中,注意用电安全,防止触电。
地暖热水机功能说明书JY20110121V1 0 - commented
地暖热水机电控板规格书一.概述1.适用于水源地暖热水机系统,并配有线控液晶操作面板,正常温度显示范围是-19℃—80℃,电源为220V/50Hz;Please change to -40⁰ - 55⁰C. 230V/50Hz.2.这不仅简化了操作、安装工程,同时也降低了成本。
最主要的是系统运行更科学、更合理、更可靠。
3.基本功能1)工作模式:热水模式和地暖模式(热水模式优先);2)可显示热水温度及地暖回水温度,具有查询功能;3)掉电自动记忆各种参数(可选);4)具有完善的保护功能及显示;5)具有定时开关机功能(实时开关)、带电池(可自动充电);6)温度控制精度: 1℃7)单台压缩机控制运行;8)感温器故障自检功能;9)液晶显示带背光(可选不带背光);4.电控板的控制信号1)压缩机×1:单压缩机系统(220V);2)水泵×2(220V);3)辅助电加热×1(220V);4)三通电磁阀×1(220V);5)温度感温探头×8(热水出水、热水回水、热水水箱、水源出水、水源回水、电加热出水、外环境、压缩机排气);6)操作面板通信(线控);7)保护开关×2(高压开关【常闭】、低压开关【常闭】);8)pressure meter x 2.二.要求1.上电后,[开/关]键旁边的绿灯亮,待机状态:显示时间、水温(无3分钟延时);断电重开:原已开机,则恢复模式(有3分钟延时);a.热水模式启停过程:热水运行流程:水源水泵启动——热水水泵启动——三通电磁阀启动——压缩机启动;退出动行流程:压缩机关闭——热水水泵关闭——三通电磁阀关闭——水源水泵关闭。
b.地暖模式启停过程:地暖运行流程:水源水泵启动——热水水泵启动——压缩机启动;退出动行流程:压缩机关闭——热水水泵关闭——水源水泵关闭。
2.温度设定范围:热水:25~60℃,地暖:根据外环境温度确定(可调)。
3.压缩机[×1(220V)]1)启停条件:热水模式:开启条件为水箱温度≤设置温度—回差温度(默认5℃,范围2℃—15℃),关的条件为水箱温度≥设置温度;地暖模式:开启条件为热水回水温度≤设置温度—回差温度(默认3℃,范围1℃—15℃),关的条件为热水回水温度≥设置温度;2)开启后3分钟内不会因回水温度的变化而停止运行;3)关闭后再开启必须有3分钟延时;4.热水水泵 [×1(220V)]1)在压缩机启动前,热水水泵先启动;2)在压缩机关闭后,热水水泵才关闭;3)在地暖模式时,压缩机关闭后,热水水泵启动3分钟(可调整)后,若回水温度≥设置温度-回差温度+1℃,则水泵停止运行,处于待机状态。
地暖清洗机使用方法
地暖清洗机使用方法地暖清洗机是一种专门用于清洗地暖系统的设备,可以有效清除地暖管道内的污垢和杂质,保障地暖系统的正常运行。
下面将详细介绍地暖清洗机的使用方法。
一、准备工作1. 确保地暖系统已关闭并排空,确保系统中没有水。
2. 准备好地暖清洗机、清洗剂和相关工具。
二、连接地暖清洗机1. 将地暖清洗机的进水管连接到冷水管道,确保连接紧固,无漏水现象。
2. 将地暖清洗机的排水管连接到下水管道,确保连接紧固,无漏水现象。
三、添加清洗剂1. 将清洗剂按照说明书的比例加入地暖清洗机的水箱中。
2. 确保清洗剂充分溶解在水中,搅拌均匀。
四、启动地暖清洗机1. 按照地暖清洗机的说明书操作,启动设备。
2. 设置清洗时间和温度,一般建议清洗时间为1-2小时,温度控制在40-60摄氏度之间。
五、清洗地暖系统1. 打开地暖系统的进水阀,使清洗剂进入地暖管道。
2. 打开地暖系统的排水阀,将污水排出。
3. 重复以上步骤,直到排出的水变清为止,表示地暖系统已清洗干净。
六、冲洗地暖系统1. 关闭地暖清洗机,切断电源。
2. 打开地暖系统的进水阀,用清水将地暖管道冲洗干净,确保清洗剂和污垢完全清除。
3. 打开地暖系统的排水阀,将冲洗后的水排出。
七、整理设备1. 关闭地暖系统的进水阀和排水阀。
2. 拆除地暖清洗机的进水管和排水管,注意防止漏水。
3. 清洗地暖清洗机的水箱和过滤器,确保设备干净。
八、检查地暖系统1. 检查地暖系统的阀门和管道是否正常,是否有漏水现象。
2. 检查地暖系统的温度和热效果,确保正常运行。
九、清洗机维护1. 清洗机使用完毕后,及时清洗和保养设备,避免污垢堆积。
2. 定期检查清洗机的零部件,确保设备正常运行。
以上就是地暖清洗机的使用方法。
使用地暖清洗机可以有效清洁地暖系统,保障其正常运行。
在操作过程中要遵循正确的步骤和要点,确保安全和效果。
希望以上内容对您有所帮助。
地暖清洗机使用方法
地暖清洗机使用方法地暖清洗机是一种专门用于清洁和维护地暖系统的设备。
它通过一系列的操作和步骤来清洗和冲洗地暖管道,以保持地暖系统的正常运行和高效工作。
下面是地暖清洗机的使用方法及步骤:第一步:准备工作1.在使用地暖清洗机之前,确保地暖系统已经关闭,并且压力已经释放。
2.检查地暖系统的管道和连接部件,确保没有漏水或松动的问题。
3.打开地暖系统的进水和出水阀门,将清洗机与地暖管道相连接。
第二步:准备清洗液1.根据地暖系统的材质和清洗需求,选择合适的清洗液。
一般来说,有机酸清洗剂和碱性清洗剂是常用的选择。
2.根据清洗液的说明,将适量的清洗液倒入地暖清洗机的水箱中。
第三步:准备清洗机1.确保地暖清洗机的电源已经连接,并且电源开关已打开。
2.操作人员应该佩戴好安全设备,如手套和护目镜。
第四步:开始清洗1.打开地暖清洗机的运行开关,让清洗液通过地暖管道流动。
2.地暖清洗机会产生一定的压力,在管道中形成高速水流,清洗管道内的污垢。
3.通过观察清洗机上的压力表和流量表,调整清洗机的运行参数,以确保适量的清洗液流经管道。
4.清洗机需要运行一段时间,以确保清洗液充分进入管道并清洁污垢。
5.在清洗过程中,操作人员应观察地暖管道的情况,确保清洗液能够顺畅地流过并将污垢冲洗干净。
第五步:冲洗管道1.在清洗完成后,关闭地暖清洗机的运行开关,并关闭地暖系统的进水和出水阀门。
2.打开冷水阀门,让清水通过地暖管道冲洗一次,以清除剩余的清洗液和污垢。
3.重复冲洗过程,直到冷水变清为止。
第六步:清洗机维护1.清洗完成后,关闭地暖清洗机的电源,并断开电源连接。
2.清洗机的水箱应该清理干净,避免残留的清洗液对设备造成损害。
3.检查地暖清洗机的各个部件,确保正常运转,并进行必要的维护保养。
总结:使用地暖清洗机可以有效清洁地暖管道,去除其中的污垢和堵塞,提高地暖系统的热效率和运行质量。
在使用地暖清洗机之前,需要做好相关的准备工作和了解清洗液的性质,以确保地暖清洗机的安全操作和清洁效果。
地暖清洗机说明书
全自动微电脑操纵脉冲地暖清洗机说明书一、地热为啥需要清洗?一样情形下,地热管路在运行一个采暖期以后会沉积毫米厚的水垢、粘泥,并相应的使室内温度降低3-6度,水质差的地域加倍严峻。
若是管路长期得不到有效清洗,一方面水流量减孝流速变慢,室内温度也因此明显下降;另一方面更为严峻的是有的会造成管路栓塞,无法疏通,致使地热管路永久失效,不可逆转。
因此地热管一样2-4年需要清洗一次,保证地热系统的正常工作。
二、何谓脉冲地热清洗机?所谓脉冲,是指间歇性的冲击波。
脉冲地热清洗机其原理确实是将水和气分段注入地热管道,在高压气体的作用下,介质水产生空爆效应,对管路内的淤泥、挂垢进展猛烈冲洗,以抵达疏通扩径的目的,从而恢复地热管路原先的口径,增大热水的流量和流速。
大伙儿明白,一杯90摄氏度的水所含的热量,远远不及一桶40摄氏度的水所含的热量。
流量增大,自然所含的热量也就增大。
脉冲清洗机的原理就在于解决地热管道淤塞问题。
三、工作原理:全自动微电脑操纵脉冲地暖清洗机是我公司依照连年现场清洗经历自主研制的新一代变频脉冲地暖清洗机,该机利用可控气压脉冲原理,将气水混合介质以极高的速度射入管路,形成空爆射流和刹时冲击波,对管路内壁的结垢和存积淤泥物进展猛烈的冲洗和震荡,迅速剥落并推出管外,抵达疏通清洗管路的目的。
四、构造组成:8 1 4 9 5 6 3 7 21:气、水全自动脉冲发生器〔主控箱〕:是产生高压气体脉冲的要紧部件,将气与水结合在全自动脉冲操纵器的操纵下形成高压水射流与气流进展清洗工作;2:空气紧缩机:产生较高的高压空气,为清洗提供充沛的空气动力。
3:连接收:连接清洗机和地热分水器,连接清洗机和水源,连接清洗机和空气紧缩机,连接分水器回水至排污点。
4:系统压力表5:脉冲调剂器〔后见详细利用〕6:系统操纵开关7:工作指示灯8:系统压力调剂阀〔在主控箱侧面〕9:遥控器a b ca.显示窗口〔显示脉冲参数〕b.左部设置区〔设置脉冲参数〕c.右部设置区〔设置脉冲频率〕五、面板操作说明:〔机型不同,操作不同〕六、清洗施工程序:(一) 连接1. 关闭分水器上水、回水分隔总阀;和每一路切断阀,泄掉地热系统内部剩余压力;2. 连接脉冲导入管,将脉冲清洗机〔脉冲输出口〕与分水器上水总承堵头端连接;3. 连接输水管,将水源和脉冲冲清洗机〔入水口〕连接;4. 连接输气管,将您的空气紧缩机出气口和脉冲清洗机〔进气口〕连接;5. 连接排污管,一端连接分水器上水堵头端,将另一端插入地漏。
LG 地暖类空气洗面浴机安装说明书
LG Floor Standing Type Air ConditionerINSTALLATION MANUALwebsite e-mail /techsup.html• Please read this installation manual completely before installing the product.• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.• Please retain this installation manual for future referenceafter reading it thoroughly.OUT-LINE OF INSTALLATIONSafety PrecautionsInstallation Manual34Floor Standing type Air ConditionerSafety PrecautionsDo not modify or extend the power cable.• There is risk of fire or electric shock.Be cautious when unpacking and installing the product.• Sharp edges could cause injury.Be especially careful of the case edges and the fins on theFor installation,always contact the dealer or an Authorized Service Center.• There is risk of fire, electric shock, explosion,• It may cause injury, accident, or damage to • If the base collapses, the air conditioner could fall with • Moisture may condense and wet or damage Do not store or use flammable gas or combustibles near the product.• There is risk of fire or failure of product.Safety PrecautionsInstallation Manual5Installation of UnitInstallation of Unit 1.Indoor unit Array• There should not be any heat source orsteam near the unit.• There should not be any obstacles toprevent the air circulation.• A place where air circulation in the roomwill be good.• A place where drainage can be easilyobtained.• A place where noise prevention is takeninto consideration.• Do not install the unit near the door way.• Ensure the spaces indicated by arrowsfrom the wall, ceiling, or other obstacles.• The indoor unit must keep themaintenance space.2.Outdoor unit• If an awning is built over the unit to preventdirect sunlight or rain exposure, be carefulthat heat radiation from the condenser isnot restricted.• There should not be any animals or plantswhich could be affected by hot airdischarged.• Ensure the spaces indicated by arrowsfrom the wall, ceiling, fence or otherobstacles.6Floor Standing type Air ConditionerInstallation of UnitInstallation Manual78Floor Standing type Air ConditionerInstallation of UnitOutdoor unit InstallationWallCore Drill1.The mounting floor should be strong and solid enough to prevent it from vibration.2.Drill the piping hole with 70mm diameter hole-core drill at either the right or the left of indoor unit.The hole should be sightly slant to the outdoor side.3.Insert the plastic tube through the hole.4.Cut the extruded outside part of the plastic tube, if necessary.1.Install the outdoor unit on the concrete or any solid base securely and horizontally by securing it with bolts (Ø12mm) and nuts.2.If there is any vibration transmitted to the building, mount the rubber underneath the outdoor unit.Refrigerant amountBefore shipment, this air conditioner is filled with the rated amount of refrigerant including additional amount required for air-purging,subject to 5m piping length.(The rated amount of refrigerant is indicated on the name plate.)But when the piping length exceeds 5 meters,additional charge is required according to the following table.Example) 28K/30KIn case of 10m long pipe(one-way), the amount of refrigerant to be replenished is:(10 - 5) x 30 = 150g(Unit:g)Installation Manual9Installation of UnitNo.Installation worksDescriptions1Preparation of tools and installation parts Preparation of installation2Flaring the pipesT o insert the flare nuts, mounted on the connection parts of both indoor and outdoor unit, onto the copper pipes.3Pipe bendingT o reduce the flow resistance of refrigerant.4Connection of installation parts Connection of long piping(elbows, socket etc)5Tighten the flare nut (outdoor) Connecting the pipings of the outdoor unit.6Blowing the pipings T o remove dust and scale in working.7Tighten the flare nut (indoor)Connecting the pipings of the indoor unit.8Check a gas-leakage of the connecting part of the pipings.9Vacuum drying of the piping and indoor unitThe air which contains moisture and which remains in the refrigeration cycle may cause a malfunction on the compressor10Open the 3-way (liquid side) and 3-way (gas side) valves.11Form the pipingsT o prevent heat loss and sweat12Checking the drainage (indoor unit) T o ensure if water flow drain hose of indoor unit.13Connecting the cable between outdoor Preparation of the operatingand indoor unit14Connecting the main cable to outdoor unit 15Supply the power to the crankcase heater T o prevent the liquid back to the compressor.(Before the operating the unit)(Heat pump only)16Cooling operation(Use the remote control or display of the indoor unit)Installation of Unit10Floor Standing type Air ConditionerInstallation Manual11Installation of Unit12Floor Standing type Air ConditionerInstallation of Unit• Align the center of the pipings and suffciently tighten the flare nut with fingers.• Finally, tighten the flare nut with troque wrench until the wrench clicks.When tightening the flare nut with troque wrench, ensure the direction for tightening follows the arrow on the wrench.1.If it is necessary to bend or stretch the tubing,use the spring which is attached to the tubing in stead of pipe bender.• Please make a careful notice to make a smooth line.• Hold the tubing with your two hands closely and then bend or stretch it slowly not to make any crack.• Remember that the radius (R) should not exceed 70mm (Refer to Fig.1)2.Do not repeat the bending process to prevent the tubing from cracking or crushing.3.Keep in mind that the bending part should not be cracked and make the radius (R) as long as possible (Refer to Fig.2)PIPE SIZETORQUE 1/4" 1.8 Kg .m 3/8" 4.2 Kg .m 1/2" 5.5 Kg .m 5/8" 5.5 Kg .m 3/4"6.5 Kg .m1.Move the indoor tubing and drain hose to the hole• Remove tubing holder and pull the tubing out of the chassis.2.Replace the tubing holder into original position 3.Route the tubing and the drain hose staight backwards.4.Insert the connecting cable into the indoor unit through the hole.• Do not connect the cable to the indoor unit• Make a small loop with the cable for easy connection later.5.Tape the tubing and the connecting cable.6.Indoor unit installation.7.Connecting the pipings to the indoor unit.).Connect the cables(LG doesn't sypply) to the Terminal Block in the front Bracket. Secure the terminal block cover to the original position with the screw.Installation of Unit1.Align the center of the pipings andsufficiently tighten the flare nut with fingers.2.Finally tighten the flare nut with torque wrench until the wrench clicks.• When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.1.Open the control board cover from the outdoor unit by removing the screws.2.Connect wires to the terminals on the control board individually and secure the cables onto the control board with clamp.3.Secure the control board cover to the original position with the screws.CAUTION:Perform grounding PIPE SIZETORQUE 1/4" 1.8 Kg .m 3/8" 4.2 Kg .m 1/2" 5.5 Kg .m 5/8" 5.5 Kg .m 3/4"6.5 Kg .mInstallation of UnitInstallation Manual15Installation of UnitThe air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor.1.Confirm that both the liquid side valve and the gas side valve are set to the closed position.2.After connecting the piping, check the joints for gas leakage with gas leak detector.3.Remove the service port nut, and connect the gauge manifold and the vacuum pump to the service port by the charge hose.4.Vacuum the indoor unit and the connecting pipes until the pressure in them lowers to below -76cmHg.5.Remove the valve stem nuts, and fully open the stems of the 2-way and 3-way valves with a hexagon wrench.6.Tighten the valve stem nuts of the 2-way valve and 3-way valve.7.Disconnect the charge hose and fit the nut to the service port.(Tightening torque:1.8kg.m)16Floor Standing type Air ConditionerInstallation of UnitInstallation Manual1718Floor Standing type Air ConditionerFinal Check and Test RunAfter installing the unit, perform the final check and running test as follows:Final check pointsIs the unit securely mounted?Is the installation location adequate?Is the water piping work adequately andwithout leakage?Are trapped drain lines installed atcondensate drain connections?Has the refrigeration cooling cycle beenkept sealed?Is the electrical wiring adequate and are the screws tightened on terminals?After the above final checkings, prepare therunning test as follows:Connect compound gauges to the check joints at discharge and suction sides ofthe compressor.Turn all switches "OFF".Turn the main switch "ON".Running test should be accomplished as follows:Set operation switch at "FAN" and the fan will start.Check to ensure that the fansounds normal.Next,set it at "COOL" and thecompressor will start.Check to ensurethat the compressor sounds normal.Check discharge and suction pressure onthe compound gauges.Check working voltage,phase balanceand running current.Check to ensure that the thermistorfunctions properly.Check to ensure that the high pressure control switch functions correctly.Final Check and Test RunP/No.:3828A20025V。
清洗机说明书
清洗机说明书清洗机说明书篇一:超声波清洗机使用说明书超声波清洗机说明书目一、概述二、技术参数三、使用环境四、使用方法五、注意事项六、售后服务七、出厂配置录一、概述1、清洗原理超声波清洗机是由超声波信号发生器(电源)产生的高频振荡信号通过换能器(振子)转化成高频机械振荡并传播到液体中,超声波在液体中疏密相间地向前辐射并产生数以万计的微小气泡,这些气泡在传播过程中的负压区形成、生长,而在正压区迅速闭合,在这种被称之为“空化效应”的过程中,气泡闭合可形成上千个大气压的瞬时高压,连续不断的产生的高压就像无数小“爆炸”不断冲击物体表面,使物体表面及缝隙中的污垢迅速剥落,从而达到清洗目的。
数控系列超声波清洗机采用LED人机交互界面,数字显示,友好清晰,直观方便。
该机性能稳定、可靠,深受广大用户的喜爱。
2、用途TH系列超声波清洗机是采用成熟的电路设计、优质进口元器件和先进的加工工艺制造而成的新一代功率超声清洗设备,工作可靠,效率高,输出功率稳定。
广泛应用于制药企业玻璃瓶、胶塞、各种滤芯滤网的清洗;金属非金属结构件电镀前的处理;电子、光学、仪表等精密部件的清洗;饰品、贵金属、稀有金属的清洗;微粉分级处理及过滤筛的清洗;化纤喷丝头、喷丝板的清洗;汽修行业发动机、油泵油嘴、化油器的清洗;生物化验室中的提取、除气及医疗器械的清洗等诸多领域。
3、性能特点(1)清洗效率高,能批量处理被清洗物。
(2)清洗效果好,不损坏被清洗件,被清洗件清洁度整体一致。
(3)操作工人不接触清洗液,安全可靠,省时省力。
(4)特别适用于清洗几何形状复杂的工件,无孔不入,无微不致。
二、技术参数1、超声功率:300 W(数显,40%-100%功率可调)2、超声频率:40KHz3、清洗时间任意设定:1—199min 分辨率1min4、温度控制:常温——80度,加热功率:400W5、工作电源:.50Hz(外供电源必须接地)6、清洗槽内尺寸:300× 240 × 150 mm3三、使用环境1、环境温度10℃—30℃,清洗液温度10℃—50℃2、相对湿度≤80%3、大气压力86~106Kpa4、连续工作时间≤60min四、使用方法清洗机说明书篇二:超声波清洗机产品说明书超声波清洗机产品说明书一、概述HHHG系列超声波清洗机是本公司开发生产的系列化批量生产产品之一,以水基溶剂作为超声波清洗介质,具有超声功率强劲,清洗工艺简单,快捷高效经济,适用于实验室、生产车间批量作业,广泛应用于清洗各类机动车辆零部件、液压气动元件、机械轴承、管件、阀门、电镀件、五金抛光件及下列各行业的除油、除腊、除污垢等清洗工艺:1.电子:电子线路板、电脑零部件、打印头、半导体、光学镜片、电真空零件磁性材料等;2.轻工:钟表零件、制笔件、照相机零件、玻璃制品、眼睛部件等;3.卫生:各种医疗保健器械、药品器具、容器等;4.化工:化学试剂容器、化学纤维喷头、喷丝板、密封容器;5.工艺:珠宝首饰、金属饰品、工艺品等;6.五金:刀具量具、硬质合金工具、金钢砂筛网、不锈钢餐具、各种冲压抛光件等;7.电镀前清洗:除油污、抛光蜡;8.维修行业:汽车维修清洗、内燃机维修清洗。
意大利ALBERTI starjet冷热水高压清洗机使用说明
意大利ALBERTI starjet冷热水高压清洗机使用说明1、开机前的准备开机前检查清洗机各部位螺钉、螺母是否有松动现象,泵偏心轴箱内已加入30或40机油,需检查油位(正好漫过油镜为益)。
2、进水管连接将进水胶管套在泵体的进水口接头上,然后套上喉卡,拧紧喉卡上的螺钉,保证连接牢固且不漏气。
然后按水源的情况将另一端套在自来水龙头上或放入供水池中(进水口必须完全浸入水中),进水管要求安装过滤器,以免吸入的杂质损坏高压泵。
3、出水管连接把高压胶管的插入接头端与机具出水口上的快换接头相连;另一端与喷枪扳机式阀上的螺纹接头相连。
接法参见结构图(快换接头的接法:只要把滚花套筒向后推,再把接头往里推平即可)。
注意:高压水管不能绞结,尽量延展、拉直。
4、电源连接首先要确定电源电压与标牌规定相一致,清洗机所采用的固定电源的连接应由专业人员进行,并应符合GB/T16895的要求。
如果使用延伸电源线,插头和插座应是防水结构的。
连接插座时,必须将清洗机的开关定在“关”的位置。
5、可更换式喷头本机喷枪可通过更换喷头调节喷出水流,短枪头为圆孔束状水流,长枪杆为扇形水流。
圆孔束状水流——该喷头能产生束状强力射流,用于污垢特别严重的表面。
如农业机械、建筑机械等。
扇形水流——该喷头产生扇形射流,散射角大,对被清洗物体的冲击力小,能用于大面积污垢表面的清洗,如轿车、公共汽车、卡车、拖接机和其它各种车辆、船舶;菜场及食品加工场,宾馆厨房;浴池、游泳池;畜舍及畜牧栅栏,高层建筑的外墙清洗等。
6、启动机器检查进水管与出水高压管已经连接可靠,电源插座接好,就可以接通电源,扣动喷枪的扳机,待机具内的空气排净后,即可有高压水喷出。
首次使用时,空气排放较慢,可先将出水高压管取下,待出水接头处有水喷出已无气体时关机,由快速接头处接上高压管,再重新开机使用。
7、若用水箱向泵供水时,应在开机的同时,从进水管向泵内灌水,半扣动喷枪的扳机,以使管路中的空气排出,待泵正常工作后,将进水管置于水箱中即可。
地暖清洗机使用方法
地暖清洗机使用方法地暖清洗机使用方法地暖清洗机使用方法(一) 连接1. 关闭分水器上水、回水分隔总阀;2. 连接脉冲导入管,将数字电脑脉冲发生器与分水器上水总承堵头端连接;3. 连接输水管,将水源和电脑脉冲发生器连接;4. 连接输气管,将空气压缩机和电脑脉冲发生器连接;5. 连接排污管,一端连接分水器回水总承堵头端,加一端插入地漏。
(二) 启动、清洗1. 接好空气压缩机和数字电脑脉冲发生器电源,按下脉冲发生器上电源开关,启动压缩机使其工作达到额定压力8Mpa;2. 打开压缩机输气开关和系统供水阀;3. 打开分水器上一个分隔阀,其它分隔阀关闭,洗一根开一修正根一根清洗;4. 排污端见到回水后,操作控制器控制数字电脑脉冲发生器发射物理脉冲波进入地热管路开始清洗。
根据地热管的长度、安装时间和挂垢状态可自行调整脉冲清洗频率进行清洗。
直至清洗干净。
地暖清洗机哪种好地暖清洗机哪种好之暖立通地暖清洗机电源:独家采用国家名牌漏电保护器,使机器使用更安全,避免了低压电源不能连续长时间工作的缺点,使您的财富源源不断。
压力表:抗震压力表,内部充有阻尼油,绝非普通压力表可比。
(专门适用于脉冲气压),使管道内压力可见。
在清洗地热过程中,难免会遇到堵塞严重的“死管”,或者因沉积物过多导致杂质大量聚集在排污接口处,使管路内部压力迅速升高。
耐震压力表可以随时反映管路内部压力变化情况,以便操作者及时采取措施。
并且耐震压力表绝非普通压力表可比,不会因为剧烈的脉冲压力导致压力表失灵。
控制器:采用通过CCC和CE国家强制认证的名厂产品,绝非便宜货输出压力控制阀:使管道内压力可调可控,稳定,避免因地热管材质问题发生爆管事故。
调节器:国家名牌产品,使用更放心,寿命更长久。
外壳:独家采用进口高纯度不锈钢,耐腐蚀,更美观更坚固。
地暖清洗机哪种好之脉冲地热清洗机空气压缩机:生产8个压力的高压空气,为清洁提供空气动力。
气、水脉冲发生器:是生产气压脉冲的主要部件,将气水结合后,在脉冲控制器的控制下工作。
清洗机使用说明书(最终版)_pdf
清洗机使用说明书 自动清洗机说明书All rights reserved未经许可,不得翻印Page 1 of 16 自动清洗机使 用说明书纳金 Nanometals 使用说明书 Operrating InstructionsNJ-QXJ-001 自动清洗机(工业用途) Automatic Cleaning Machine (Industial)感谢使用纳金科技清洗机产品 在安装、使用与维修前请仔细阅读本手册以期发挥最佳性能并维护安全All rights reserved未经许可,不得翻印Page 2 of 16 自动清洗机使 用说明书目录●安全注意事项 ●重要信息●清洗机主要规格参数 ●零部件名称和附图说明 ●显示屏附图说明及含义 ∙主界面 ∙手动画面 ∙参数设置 ●使用步骤 ∙触膜屏的设置 ∙锥形瓶的固定 ∙启动程序 ∙其他方面 ●维护及保养All rights reserved未经许可,不得翻印Page 3 of 16 自动清洗机使 用说明书安全注意事项●启动机器前,必须穿实验服,戴手套,带口罩,带上护目眼镜 (否则可能会导致轻微中毒,灼伤皮肤和眼睛) ●禁止将头伸入,通风橱里的机器中,以免发生意外 (否则可能会导致轻微中毒,或者头部会被夹伤) ●启动机器前,必须将通风橱的开关打开(否则可能会导致有害气体不能够及时排出,人体接触会轻微 腐蚀和中毒)●请把放锥形瓶的槽格都装满,装满后务必把固定盖板合上 (否则可能会导致部分强酸强碱,溅出水槽以外,腐蚀部分零 件,机器寿命变短)●严禁不戴手套直接用手触碰固定盖板 (否则可能会导致触碰的部位被轻微腐蚀) ●在机器运行时严禁将通风橱中的开关断开(否则可能会导致清洗中的有害气体不能及时排出实验室外) ●在机器运行时,出现紧急情况,立即断开电源 (否则可能会导致冒烟、起火、触电或腐蚀)All rights reserved未经许可,不得翻印Page 4 of 16 自动清洗机使 用说明书若工作中出现以下异常或故障 ∙喷头结构没有正常的上或下移动 ∙长形喷头没有正常的喷出液体 ∙旋转放置机构没有正常的左右翻转 ∙排液时电磁阀没有按照设定次序打开排液管 ∙电磁阀出现异常,不能止水或同时打开 ∙光电感应器异常亮起 ∙存在其他异常情况或故障请立即按掉显示屏上的“停止”开关,上述任一情况若依 然存在异常则立即按掉总电源,并与客户咨询服务中心联系进 行检查和修理。
清洗机使用说明书最终版pdf模板
清洗机使用说明书最终版pdf1清洗机使用说明书自动清洗机说明书All rightsreserved未经许可,不得翻印Page 1 of16自动清洗机使用说明书纳金Nanometals使用说明书Operrating InstructionsNJ-QXJ-001 自动清洗机(工业用途)Automatic Cleaning Machine (Industial)感谢使用纳金科技清洗机产品在安装、使用与维修前请仔细阅读本手册以期发挥最佳性能并维护安全清洗机使用说明书自动清洗机说明书All rightsreserved未经许可,不得翻印Page 2 of16自动清洗机使用说明书目录●安全注意事项●重要信息●清洗机主要规格参数●零部件名称和附图说明●显示屏附图说明及含义∙主界面∙手动画面∙参数设置●使用步骤∙触膜屏的设置∙锥形瓶的固定∙启动程序∙其它方面●维护及保养说明书All rights reserved未经许可,不得翻印Page 3 of16自动清洗机使用说明书安全注意事项●启动机器前,必须穿实验服,戴手套,带口罩,带上护目眼镜(否则可能会导致轻微中毒,灼伤皮肤和眼睛)●禁止将头伸入,通风橱里的机器中,以免发生意外(否则可能会导致轻微中毒,或者头部会被夹伤)●启动机器前,必须将通风橱的开关打开(否则可能会导致有害气体不能够及时排出,人体接触会轻微腐蚀和中毒)●请把放锥形瓶的槽格都装满,装满后务必把固定盖板合上(否则可能会导致部分强酸强碱,溅出水槽以外,腐蚀部分零件,机器寿命变短)●严禁不戴手套直接用手触碰固定盖板(否则可能会导致触碰的部位被轻微腐蚀)●在机器运行时严禁将通风橱中的开关断开(否则可能会导致清洗中的有害气体不能及时排出实验室外)●在机器运行时,出现紧急情况,立即断开电源(否则可能会导致冒烟、起火、触电或腐蚀)说明书All rights reserved未经许可,不得翻印Page 4 of16自动清洗机使用说明书若工作中出现以下异常或故障∙喷头结构没有正常的上或下移动∙长形喷头没有正常的喷出液体∙旋转放置机构没有正常的左右翻转∙排液时电磁阀没有按照设定次序打开排液管∙电磁阀出现异常,不能止水或同时打开∙光电感应器异常亮起∙存在其它异常情况或故障请立即按掉显示屏上的“停止”开关,上述任一情况若依然存在异常则立即按掉总电源,并与客户咨询服务中心联系进行检查和修理。
分钟人 EX12 地毯清洁机使用说明书
Parts and Instruction ManualThis manual is furnished with each new MINUTEMAN EX12 . This provides the necessary operating and preventive maintenance instructions. Operators must read and understand this manual before op-erating or servicing this machine.This machine was designed to give you excellent performance and efficiency. For best results and minimal cost, please follow the general guidelines below:· Operate the machine with reasonable care.· Follow the manufacturers suggested maintenance instructions as provided in this booklet.· Use original Minuteman supplied parts.TECHNICAL SPECIFICATIONS ModelEX 12 EX12H 121153 Stage 100 cfm100 psi N/A 12 gal.50’ (15m) 12-312” (30.5cm)5” (13cm)99 lbs (45kg)19” (48cm)30” (76cm)48” (122cm)Model No.Vac Motor Pump Heater Capacity Cord(s)Wheels Casters Weight Length Width Height12115H 3 Stage 100 cfm250 psi2000 watt - 210° Max Temp12 gal.(2) 50’ (15m) 12-312” (30.5cm)5” (13cm)118 lbs (53.5kg)19” (48cm)30” (76cm)48” (122cm)Table of ContentsSafety Precautions (1)Grounding Instructions (1)Safety Labels (2)Electrical Requirements (2)Machine Components (2)Machine Set Up (3)Operation (4)Draining Recovery Tank (4)Machine Maintenance (4)Maintenance (4)Weekly Maintenance (4)Troubleshooting (5)Storing Machine (5)Exploded Views (7)EX12 - Base Assembly (7)EX12 - Solution Tank Assembly (8)EX12 - Recovery Tank Assembly (9)EX12 - Bill Of Materials (10)EX12H - Base Assembly (11)EX12H - Solution Tank Assembly (12)EX12H - Recovery Tank Assembly (13)EX12H - Bill Of Materials (14)Minuteman International Made Simple Commercial Limited Warranty (15)4. Before leaving or servicing machine:-Turn off machine.-Unplug cord from wall outlet.5. When servicing machine:-Unplug cord from wall outlet.-Avoid moving parts.-Do not wear loose jackets, shirts, or sleeves.-Use manufacturer supplied or approved replacement parts. WARNING: Hazardous Voltage. Shock or electrocution can result. Always unplug machine before servicing.WARNING: Flammable materials cancause an explosion or fire. Do not use flammable materials in tank(s).WARNING: Flammable materials orreactive metals can cause an explosion or fire.Machine must be grounded. If it shouldmalfunction or breakdown, grounding provides a path of least resistance for electrical shock. This machine is equipped with a cord having anequipment-grounding conductor and grounding plug. The plug must be plugged into anappropriate outlet that is properly installed in accordance with all local code and ordinances.Do not remove ground pin; if missing, replace plug before use.Grounding InstructionsThis machine is intended for commercial use. It is designed to clean carpet and upholstery in an indoor environment and is not constructed for any other use. Use only recommended cleaning solutions and accessory tools.All operators must read, understand and practice the following safety precautions.The following safety alerts symbols are used throughout this manual as indicated in their description:WARNING: To warn of hazards or unsafe practices which could result in severe personal injury or death.FOR SAFETY: To identify actions which must be followed for safe operation of equipment.The following information signal potentiallydangerous conditions to the operator or equipment:FOR SAFETY:1. Do not operate machine:-Unless trained and authorized.-Unless operator manual has been read and understood.-In flammable or explosive areas.-Unless cord is properly grounded.-With damaged cord or plug.-If not in proper operating condition.-In outdoor areas.-In standing water.-With the use of an extension cord.2. Before operating machine:-Make sure all safety devices are in place and operate properly.3. When using machine:-Do not run machine over cord.-Do not pull machine by plug or cord.-Do not pull cord around sharp edges or corners-Do not unplug by pulling on cord.-Do not stretch cord.-Do not handle plug with wet hands.-Keep cord away from heated surfaces.-Report machine damage or faulty operation immediately to your distributor.-Follow mixing and handlinginstructions on chemical containers.Electrical RequirementsThe safety labels appear on the machine in various locations. Replace labels if they become damaged or cannot be read.WARNING: Flammable materials can cause an explosion or fire. Do not use flammablematerials in tank(s). Flammable materials or reactive metals can cause explosion or fire.ABCDPre-Operation1. Vacuum carpet and remove other debris.2. Perform MACHINE SETUP procedures.3. Inspect power cord for damage.1. Carefully check carton for signs of damage. Report damage at once to freight carrier. The machine is shipped fully assembled and is ready for use.2. Open lid of solution tank. Fill solution tank with water or approved cleaning agent.WARNING: Flammable materials cancause an explosion or fire. Do not use flammable solutions or materials in tank(s).FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers.ATTENTION: If using powdered cleaning chemicals, mix prior to adding.3. Attach solution hose. (Located front of machine.)NOTE: Make sure the quickdisconnects snap together firmly. As you do this, always inspect hoses for cracks or fraying. Do not use if hoses are damaged.4. Attach other end of solution hose to wand.5. Attach vacuum hose to recovery tank.6. Plug machine’s cord into a grounded wall outlet.FOR SAFETY: Do not operate machine unless cord is properly grounded.FOR SAFETY: Do not operate machine with the use of an extension cord.Set Up7. Connect solution hose and make sure it is firmly secured.8. Turning machine on:A. Turn pump switch on.B. Pull up on wand lever to release air in the line. Hold lever until you have a steady flow of water coming out of the wand.C. Once pump is primed and you have pressure in the solution line, turn on heater switch(s) and wait a few minutes for water to heat up.NOTE: For best results leave pump and heater switch on for approximately 10 minutes before using as a pre-heat cycle.Also, the heater may be run in either 1000W or 2000W mode by rocking the switch up and down.D. Once water is heated, turn on vacuum motors and begin cleaning.To keep machine in good working condition, simply follow machine’s daily and weekly maintenance procedures.FOR SAFETY : When servicing machine, unplug cord from wall outlet.DAILY:1. Empty and rinse out solution tank thoroughly.2. Wipe off power cord and check for damage, replace if necessary. Coil cord neatly after use.3. Clean machine with an all purpose cleaner and damp cloth.(EVERY 20 HOURS OF OPERATION)1. Flush solution system with a system maintainer to dissolve normal chemical buildup.a. Pour 7.5L (2 gal) of hot water 60°C (140°F) into solution tank. Add system maintainer according to mixing instructions on bottle FOR SAFETY: When using machine,follow mixing and handling instructions on chemical containers.b. Operate machine for one minute.c. Shut off machine and allowremaining solution to break down chemical buildup overnight.d. Next day, spray out remaining solution and flush system with 11L (3gal) of clean water.2. Inspect vacuum hoses for holes and loose cuffs.3. Inspect spray pattern for clogging. If clogged, remove spray tips and soak them in arecommended liquid neutralizer for up to six hours. To remove spray tip, twist spray tip body counter-clockwise. Do not use pointed objects to unplug tips, damage will occur.4. Lubricate wheels with water resistant oil.5. Inspect machine for water leaks and loose hardware.6. Remove float shut-off screen from recovery tank and clean.WARNING: Flammable materials orreactive metals can cause an explosion or fire.Do not pick up.1. Work away from outlet and power cord to prevent cord damage.2. Use a recommended foam control solution in the recovery tank to prevent vacuum motor damage. Periodically check for excessive foam buildup in solution tank.3. To clean heavily soiled areas, repeat cleaning path from different direction.4. When ball float shuts off vacuum, it is time to empty the dirty water from the recovery tank, and refill solution tank.NOTE: When cleaning upholstery, always check cleaning instructions sewn in furniture by manufacturer5. After cleaning, relieve water pressure from tool before disconnecting hose. Squeeze trigger for five seconds after turning main power switch off.FOR SAFETY : When servicingmachine, unplug cord from wall outlet.1. Turn machine off and unplug power cord.2. Remove solution & vacuum hose3. Lift up drain valve lever to empty solution tank.Operation Draining Recovery TankMachine MaintenanceWeekly MaintenanceMaintenanceStoring MachineTroubleshooting1. Before storing machine, be certain to completely drainandrinse tanks of all water and solution.2. Drain and dry the vacuum hose as well, using the drain hose provided3. Store machine in a dry area in the upright position.4. Open recovery tank cover to promote air circulationSYMPTOM:UNIT WILL NOT TURN ON:PROBLEM:Not plugged in.SOLUTION:Plug machine in proper outlet.PROBLEM:Circuit breaker has popped.SOLUTION:Reset circuit breaker. Make sure no other items are running on the same circuit as machine. Outlet must be a 15-amp circuit.PROBLEM:Wire from power cord has become disconnected from terminal block.SOLUTION:Reattach wire to terminal block.SYMPTOM:PUMP IS NOT RUNNING PROPERLY:PROBLEM:Quick disconnects are not completely locked together.SOLUTION:Snap quick disconnects firmly together.PROBLEM:The solution tank is empty.SOLUTION:Fill the solution tank up with a premixed detergent.PROBLEM:Jet on upholstery tool is clogged.SOLUTION:Clean jet with soft wire brush or remove jet and flush clean.PROBLEM:Filters are clogged.SOLUTION:Remove filters and rinse clean with water.PROBLEM:Heater is blocked with hard water deposits.SOLUTION:Flush out heaters with system maintainers. If they are still blocked, replace heaters.PROBLEM:Brass check valve is stuck.SOLUTION:Replace with new check valve.PROBLEM:Pump wire has become disconnected.SOLUTION:Reconnect wire.PROBLEM:Switch on switch plate is bad.SOLUTION:Replace switch.PROBLEM:Pump motor brushes are worn out.SOLUTION:Replace pump.SYMPTOM:HEATER IS NOT WORKING PROPERLY:PROBLEM:The back up sensor, mounted on the heater has popped. SOLUTION:Reset sensor by pushing in button.PROBLEM:Heating element is bad.SOLUTION:Replace element.SYMPTOM:VACUUM MOTOR IS NOT WORKING PROPERLY: PROBLEM:Hose not connected tightly to upholstery tool or machine. SOLUTION:Connect hose tightly.PROBLEM:Drain valve is not shut completely.SOLUTION:Close drain valve completely.PROBLEM:Vacuum tank lid is not on tightly.SOLUTION:Secure the vacuum tank tightly.PROBLEM:Ball float is shut off.SOLUTION:Empty the vacuum tank of all wastewater.PROBLEM:Water is coming out of vacuum motor.SOLUTION:Use a low foaming detergent.PROBLEM:Floor wand or is clogged with hair, carpet fibers and or debris. SOLUTION:Clean floor wand.PROBLEM:Ball float is not installed correctly.SOLUTION:Make sure that ball float is firmly installed on the elbow.EX12 - Base AssemblyBill Of Material - EX12Item Part No.Qty.Description Item Part No.Qty.Description11210522 cap, axle, 1/2" 401211552 bolt, 1/4-20 x 1-1/4" hex head21210592 wheel, 12" 411211192 Bracket, L 070-03631211676 washer, axle, cut 1/2" id 421212091 sol tank, speedster41210661 axle, 1/2" x 18-1/2", sp, breeze 431210751 bracket, rear, fb/spy512116212 nut, lock, 1/4-20, nylon insert 441211606 washer, 1/4" lock, s/s612115716 washer, 1/4" flat, s/s 451210762 knob, thumb screw, for bracket71211758 bolt, 1/4-20 x 1" hex head, s/s 461210181 elbow, brass, 90 deg, 3/8"mpt x 3/8" fmpt 81210732 caster, 5" 471211732 washer, 11/16"id x 1-1/2"od x .075, s/s91212081 base, speedster 481210201 nipple, brass, 3/8" x close101210612 guard, cooling fan, wire 491210191 bushing, brass, 1/2"mpt x 3/8" fpt, hex 111212038 screw, #10 x 5/8" hex head, zinc 501210121 filter, strainer, 1/2"121211631 nut, lock, 1/2" steel 511210681 bracket, front hinge, sp/fb131210531 fitting, strain relief, cord 521212022 bolt, 1/4-20 x 1-1/2" hex head, s/s141210321 power cord, end, 25', 14/3 grey 531210052 elbow, brass, 90 deg, 1/4"mpt x 1/4" fpt 151211812 bolt, 1/4-20 x 3/4" serrated hex flange, zinc 541211594 washer, 9/16"id x 1"od, flat, s/s161211171 plate, single manifold, 6.5" x 9" 551210081 nipple, brass, 1/4"m, hex171212111 manifold, single vac 561211491 hose, 3/8" x 17-1/2", (OAL), f x -fsw, surge, 1600psi 181211545 bolt, 1/4-20 x 1/2" hex head, zinc 571211772 washer, nylon, 9/16id x 1-1/16od x .031 191210381 gasket, vacuum motor 581210071 nipple, brass, 1/4" x close201211253 v ac support, 3 stage, 4-1/16" 591210101 adapter, brass, extender, 1/4" mpt x 1/4" fpt, hex 211211829 bolt, 1/4-20 x 1/2" serrated hex flange, zinc 601210041 qd, brass, 1/4" f221210211 v ac motor, 3 stage, 115V, tangential 611210691 float, 2", ball style231210421 exhaust boot, plastisol 621210771 elbow, 2" float241211261 cuff, 2" 631211351 pipe, pvc, 2"251211921 v ac hose, 2", wire reinforced 641211371 adaptor, pvc 2, fmsl x fmt261210512 clamp, hose, 2-1/4 DIA 651212002 gasket, 2" inlet polyethylene, 3" OD 2.35" ID 271211961 sol hose, 1/4" x 24 1/2", (OAL), f x fsw, 3000psi 661210551 spout, drain, 45 degree281210141 elbow, brass, 90 deg, 1/4" mpt x 1/4" mpt 671210541 valve, drain, 1-1/2"291210061 bushing, brass, 3/8"mpt x 1/4" 681212101 vac tank, speedster301210161 adapter, brass, 1/2" barb x 3/8" fsw, ball end 691211382 inlet, 2"311210171 elbow, brass, 90 deg, 1/2" barb x 3/8"mpt 701210722 washer, #8 flat, s/s321210642 clamp, hose, 5/16-29/32 711211762 screw, #10-32 x 1/2" SHCS, alloy331211901 sol hose, 1/2" kuri 100psi 721210631 plate, switch, sp, 3 hole341211694 nut, kep, #10-32 zinc 731210282 switch, rocker, 2 position351211644 screw, #10-32 x 1-1/4" phil pan head, zinc 741212171 gasket, vac lid, 6.5" i.d 7.5" o.d361210221 pump, 100psi, demand, 115V 751210441 lid, vac tank, black, 7"371211612 nut, hex, 1/4-20 s/s 761211746 screw, #8 x 5/8 phil oval, s/s381211584 washer, 1/4"id x 1"od, flat, s/s 771211141 gasket, 2" inlet391210414 washer, buna 1-1/8" od x 3/16" id 781211941 elbow, inlet assembly 2"BILL OF MATERIAL - EX12HITEM PART NO.QTY.DESCRIPTION ITEM PART NO.QTY.DESCRIPTION1 1211632 NUT-LOCK 1/2" STEEL 52 1211253 SUPPORT-VAC 3 STAGE 4-1/16"2 121053 2 FITTING-STRAIN RELIEF CORD 53 121182 9 BOLT-SERRATED 1/4-20 X 1/2"3 121032 2 CORD-POWER END 25' GRY 54 121021 1 MOTOR-VAC 3 STAGE 115V TANG4 121052 2 CAP-AX LE 1/2" 55 121042 1 EX HAUST BOOT-PLASTISOL5 121059 2 WHEEL-12" 56 121126 1 CUFF-HOSE 2 X 2 WIRE REINFORCED6 121167 6 WASHER-AX LE CUT 1/2" ID 57 121192 1 HOSE-VAC 2" WIRE REINFORCED7 121066 1 AX LE-SP 1/2" x 18-1/2" 58 121051 2 CLAMP-HOSE 2-1/4 DIA8 121208 1 BASE-SPEEDSTER BURGUNDY 59 121209 1 TANK-SOLUTION SPEEDSTER BURGUNDY9 121162 12 NUT-LOCK 1/4-20 NYL INSERT 60 121161 2 NUT-HEX 1/4-20 S/S10 121157 16 WASHER-FLAT 1/4" S/S 61 121160 6 WASHER-LOCK 1/4" S/S11 121175 8 BOLT-HEX HEAD 1/4-20 X 1" S/S 62 121158 4 WASHER-FLAT 1/4" ID X 1" OD S/S12 121073 2 CASTER-5" 63 121041 4 WASHER-BUNA 1-1/8" O.D. x 3/16"13 121023 1 FAN-COOLING 115V 64 121155 2 BOLT-HEX HEAD 1/4-20 X 1-1/4"14 121061 3 GUARD-COOLING FAN WIRE 65 121119 2 BRACKET-"L"15 121203 8 SCREW-HEX HEAD #10 X 5/8" ZINC 66 121075 1 BRACKET-REAR FB/SP16 121152 1 REGULATOR-200 PSI 67 121076 2 KNOB-THUMB SCREW FOR BRACKET17 121064 8 CLAMP-HOSE 5/16-29/32 68 121159 8 WASHER-FLAT 9/16" ID X 1" OD18 121226 1 sol hose, kuriyama, 3/8" 69 121010 3 ADAPTER-BRASS EX TENDER 1/4"19 121227 2 adapter, brass, 3/8" barb x 1/4" fsw 70 121018 1 ELBOW-BRASS 90 DEG 3/8" MPT20 121169 6 NUT-#10-32 ZINC 71 121173 2 WASHER-11/16" ID X 1-1/2"OD X .075 S/S21 121168 2 SCREW-PHIL PH #10-32 X 3/4" 72 121020 1 NIPPLE-BRASS 3/8" x CLOSE22 121228 1 bracket, heater mounting, dual 73 121019 1 BUSHING-BRASS 1/2" MPT x 3/8"23 121074 2 HEATER-ALUMINUM CAST SINGLE 74 121012 1 FILTER-STRAINER 1/2"24 121095 1 HEATING ROD-600 WATT 115V 75 121068 1 BRACKET-FRONT HINGE SP/FB25 121030 1 HEATING ROD-1000W 115V 76 121202 2 BOLT-HEX HEAD 1/4-20 X 1-1/2" S/S26 121035 2 THERMOSTAT- 200 DEG AUTO 1/4" V 77 121008 1 NIPPLE-BRASS 1/4" M HEX27 121229 8 screw, #6 x 3/16, phil pan head, self-tapping 78 121149 1 HOSE-3/8" X 17-1/2" (OAL)28 121036 2 THERMOSTAT-310 DEG F +/- 10 DEG F MAN 79 121177 2 WASHER-9/16 ID X 1-1/16 X .031 NYLON29 121005 8 ELBOW-BRASS 90 DEG 1/4" MPT 80 121004 1 QD-BRASS 1/4" F30 121151 1 HOSE- 3/8" X 6", (OAL) 81 121069 1 FLOAT-BALL STYLE 2"31 121011 1 TEE-BRASS 1/4" FPT 82 121077 1 ELBOW-2" FLOAT32 121007 4 NIPPLE-BRASS 1/4" x CLOSE 83 121135 1 PIPE-2" PVC33 121149 1 HOSE-3/8" X 17-1/2" (OAL) 84 121137 1 ADAPTOR-2" FMSL x FMT PVC34 121230 1 hose, 3/8" x 9" (OAL), f x f, surge, 1600psi 85 121200 2 GASKET-2" INLET POLYETHYLENE 3" OD 2.35" ID35 121164 4 SCREW-PHIL PH #10-32 X 1-1/4" ZINC 86 121054 1 VALVE-DRAIN 1-1/2"36 121024 1 PUMP-250 PSI BYPASS 115V 87 121055 1 SPOUT-DRAIN 45 DEG37 121231 1 plug, brass, 1/4"mpt, hex 88 121002 1 ELBOW-INLET ASSY 1-1/2"38 121131 1 VALVE-PRIME HIGH PRESSURE 89 121114 1 GASKET, 2" INLET39 121232 1 adapter, brass, 3/8" barb x 1/4"mpt 90 121044 1 LID-VAC TANK 7" BLACK40 121233 1 sol hose, kuriyama, 3/8" 91 121174 6 SCREW-PHIL OVAL #8 X 5/8 S/S41 121014 1 ELBOW-BRASS 90 DEG 1/4" MPT 92 121217 1 GASKET-VAC LID 6.5" ID 7.5" OD42 121234 1 adapter, brass, 1/2" barb x 1/4" mpt 93 121056 1 FITTING-INLET PVC 1-1/2"43 121212 1 HOSE-SOLUTION 1/2" KURI 100 PSI 21" 94 121025 2 LIGHT-RED 250V44 121104 1 FILTER CUP IN-LINE 95 121029 1 SWITCH-ROCKER 3 POSITION45 121235 1 sol hose, 1/2" kuri 100psi 96 121028 2 SWITCH-ROCKER 2 POSITION46 121016 1 REDUCER-BRASS SWIVEL BALL 97 121026 1 LIGHT-INDICATOR 125V AMBER47 121181 2 BOLT-SERRATED 1/4-20 X 3/4" 98 121176 2 SCREW-SHCS #10-32 X 1/2" ALLOY48 121117 1 PLATE-SINGLE MANIFOLD 6.5" 99 121072 2 WASHER-FLAT #8 S/S49 121154 5 BOLT-HEX HEAD 1/4-20 X 1/2" 100 121138 1 INLET-2"50 121211 1 MANIFOLD-SINGLE VAC 101 121065 1 PLATE-SWITCH SP 4 HOLE51 121038 1 GASKET-VAC MOTOR 102 121210 1 TANK-VAC SPEEDSTER BURGUNDYMinuteman International Made Simple Commercial Limited WarrantyMinuteman International, Inc. warrants to the original purchaser/user that the product is free from defects in workmanship and materials under normal use. Minuteman will, at its option, repair or replace without charge, parts that fail under normal use and service when operated and maintained in accordance with the applicable operation and instruction manuals. All warranty claims must be submitted through and approved by factory authorized repair stations.This warranty does not apply to normal wear, or to items whose life is dependent on their use and care, such as belts, cords, switches, hoses, rubber parts, electrical motor components or adjustments. Parts not manufactured by Minuteman are covered by and subject to the warranties and/or guarantees of their manufacturers. Please contact Minuteman for procedures in warranty claims against these manufacturers.Special warning to purchaser -- Use of replacement filters and/or prefilters not manufactured by Minuteman or its designated licensees, will void all warranties expressed or implied. A potential health hazard exits without original equipment replacement.All warranted items become the sole property of Minuteman or its original manufacturer, whichever the case may be.Minuteman disclaims any implied warranty, including the warranty of merchantability and the warranty of fitness for a particular purpose. Minuteman assumes no responsibility for any special, incidental or consequential damages.This limited warranty is applicable only in the U.S.A. and Canada, and is extended only to the original user/purchaser of this product. Customers outside the U.S.A. and Canada should contact their local distributor for export warranty policies. Minuteman is not responsible for costs or repairs performed by persons other than those specifically authorized by Minuteman. This warranty does not apply to damage from transportation, alterations by unauthorized persons, misuse or abuse of the equipment, use of non-compatible chemicals, or damage to property, or loss of income due to malfunctions of the product.If a difficulty develops with this machine, you should contact the dealer from whom it was purchased.This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions and limitations may not apply to you.Cord Electric Group………. Three years parts, two years labor, ninety days travel (Not to exceed two hours) Exceptions………. Port-A-Scrub, one year parts, six months laborMPV 13, one year partsMPV 14 and 18, two years parts, one year laborRapidAir blower, one year parts, one year laborExplosion-Proof Vacuum, one year parts, one year laborPneumatic Vacuums, three years parts, one year laborEX 12 and EX12H, one year parts, one year laborBattery Operated Group….. Three years parts, two years labor, ninety days travel(Not to exceed two hours)Exceptions……Sweepers, one year parts, one year labor, ninety days travel(Not to exceed two hours)Internal Combustion Group….One year parts, one year labor, ninety day travel(Not to exceed two hours)Replacement Parts……………..Ninety daysBatteries………………………….0-3 months replacement, 4-12 months pro-ratePolypropylene Plastic Tanks…Ten years, no additional labor111 South Rohlwing Road · Addison, Illinois 60101 USAPhone 630- 627-6900 · Fax 630- 627-1130E-Mail, 。
米费勒地暖清洗机说明书
米费勒地暖清洗机说明书米费勒地暖清洗机说明书一、产品概述米费勒地暖清洗机是一款专为地暖系统清洗而设计的高效工具。
它可以有效地清除地暖管道内的污垢、沉积物和空气,提高地暖系统的热效率,延长设备的使用寿命,并保证供暖的舒适性和健康性。
二、使用方法及步骤1. 准备工作在开始清洗工作之前,请确保地暖系统已经关闭,并确认水源和电源已正常连接。
2. 连接管路将清洗机的供水管路连接到地暖系统的入口处,确保连接紧固无漏水。
将清洗机的排水管路连接到地暖系统的出口处,同样要检查连接是否紧固。
3. 注入清洗剂打开清洗机的注入清洗剂的口,并将适量的清洗剂注入清洗机内。
根据地暖系统的规模和情况,合理调整清洗剂的用量。
4. 开启清洗机按下清洗机的开关,启动机器开始工作。
清洗机将抽取清洗剂并通过地暖系统管道循环,清除污垢和沉积物。
5. 清洗循环根据地暖系统的情况,可以选择多次循环清洗,以达到更好的清洁效果。
每次循环清洗的时间一般为30分钟到1小时,具体时间根据需要而定。
6. 排水清洗结束后,关闭清洗机的开关,并将排水装置拧紧。
打开地暖系统的放水阀,将清洗剂和污水排出。
7. 冲洗用清水冲洗地暖系统,确保清洗剂和污水完全排出。
冲洗时间应持续10至15分钟,直到冲洗出的水清澈无杂质为止。
8. 检查及后续工作关闭冲洗阀门,并检查地暖系统的各项设备和管道,确保无漏水和异常。
待系统干燥后,重新启动地暖供暖系统即可。
三、注意事项1. 在使用清洗剂时,请务必按照说明书的指导使用适量的清洗剂,过多或过少均会影响清洗效果和设备寿命。
2. 使用清洗机过程中,注意观察机器运行状态,如发现异常或故障,请及时停止使用并联系售后服务。
3. 清洗机使用后,应及时进行清洁和保养,保持设备的良好状态,并储存于干燥通风的地方。
4. 为了保证清洗效果和地暖系统的正常运行,请定期进行清洗维护,并遵循地暖系统的使用说明和保养要求。
四、总结米费勒地暖清洗机是一款功能强大、易操作的高效清洗工具,它以其卓越的清洗效果和便捷的使用方式得到了广大用户的肯定。
地暖管路清洗机技术规格
地暖管路清洗机技术规格英文回答:The technical specifications for a floor heating pipe cleaning machine can vary depending on the specific requirements and features of the machine. However, thereare some common specifications that are typically includedin such machines.Firstly, the cleaning machine should have a suitable power source, such as an electrical outlet or a battery, to operate efficiently. It should also have a sufficient power rating to ensure effective cleaning of the floor heating pipes.Secondly, the machine should be equipped with a pump system that can generate enough pressure to remove any dirt, debris, or sediment that may have accumulated in the pipes. The pump should have adjustable pressure settings to accommodate different pipe sizes and conditions.Additionally, the cleaning machine should have a water tank or a connection to a water source to supply the necessary cleaning solution. The tank or water source should have a sufficient capacity to ensure continuous cleaning without the need for frequent refills.Furthermore, the machine should have a set of brushes or nozzles that can be attached to the cleaning head. These brushes or nozzles should be designed to effectively scrub the interior surface of the pipes and dislodge any stubborn dirt or deposits.Moreover, the cleaning machine should have a control panel or interface that allows the user to adjust the cleaning parameters, such as pressure, water flow, and cleaning time. The control panel should be user-friendly and intuitive to operate.In terms of safety features, the machine should have an automatic shut-off mechanism to prevent overheating or damage in case of any malfunction. It should also have abuilt-in filtration system to prevent any debris or particles from entering the pump or other sensitive components.Additionally, the machine should be compact and portable, allowing for easy transportation and maneuverability. It should also be durable and resistant to corrosion or damage from the cleaning solution or the environment.To illustrate the importance of these technical specifications, let's consider a scenario where I need to clean the floor heating pipes in my home. I have a cleaning machine that meets the specifications mentioned above.I start by connecting the machine to a power outlet and filling the water tank with a suitable cleaning solution. I adjust the pressure settings on the control panel based on the size and condition of my floor heating pipes.I attach the appropriate brush to the cleaning head and begin the cleaning process. The machine generates enoughpressure to effectively scrub the interior surface of the pipes, removing any dirt or debris that may have accumulated over time.As I continue cleaning, I periodically check the water tank and refill it if necessary to ensure uninterrupted cleaning. The control panel allows me to adjust the cleaning parameters as needed to achieve optimal results.After completing the cleaning process, I disconnect the machine from the power source and clean the brushes or nozzles to remove any residue. I store the machine in a safe place for future use.中文回答:地暖管路清洗机的技术规格可以根据具体要求和机器的特点而有所不同。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
全自动微电脑控制脉冲地暖清洗机说明书
一、地热为啥需要清洗?
一般情况下,地热管路在运行一个采暖期之后会沉积1-1.5毫米厚的
水垢、粘泥,并相应的使室内温度降低3-6度,水质差的地区更加严
重。
如果管路长期得不到有效清洗,一方面水流量减孝流速变慢,
室内温度也因此明显下降;另一方面更为严重的是有的会造成管路
栓塞,无法疏通,导致地热管路永久失效,不可逆转。
因此地热管
一般2-4年需要清洗一次,保证地热系统的正常工作。
二、何谓脉冲地热清洗机?
所谓脉冲,是指间歇性的冲击波。
脉冲地热清洗机其原理就是将水
和气分段注入地热管道,在高压气体的作用下,介质水产生空爆效
应,对管路内的淤泥、挂垢进行剧烈冲刷,以达到疏通扩径的目的,
从而恢复地热管路原来的口径,增大热水的流量和流速。
大家知道,
一杯90摄氏度的水所含的热量,远远不及一桶40摄氏度的水所含
的热量。
流量增大,自然所含的热量也就增大。
脉冲清洗机的原理
就在于解决地热管道淤塞问题。
三、工作原理:
全自动微电脑控制脉冲地暖清洗机是我公司根据多年现场清洗经
验自主研制的新一代变频脉冲地暖清洗机,该机利用可控气压脉冲原
理,将气水混合介质以极高的速度射入管路,形成空爆射流和瞬间冲
击波,对管路内壁的结垢和存积淤泥物进行剧烈的冲刷和震荡,迅速
剥落并推出管外,达到疏通清洗管路的目的。
8 1 4 9 5 6 3 7 2
四、结构组成:
1:气、水全自动脉冲发生器(主控箱):是产生高压气体脉冲的主要
部件,将气与水结合在全自动脉冲控制器的控制下形成高压水射流与
气流进行清洗工作;
2:空气压缩机:产生较高的高压空气,为清洗提供充足的空气动力。
3:连接管:连接清洗机和地热分水器,连接清洗机和水源,连接清洗
机和空气压缩机,连接分水器回水至排污点。
4:系统压力表
5:脉冲调节器(后见详细使用)
6:系统控制开关
7:工作指示灯
8:系统压力调节阀(在主控箱侧面)
9:遥控器
a b c
a.显示窗口(显示脉冲参数)
b.左部设置区(设置脉冲参数)
c.右部设置区(设置脉冲频率)五、面板操作说明:(机型不同,操作不同)
六、清洗施工程序:
(一) 连接
1. 关闭分水器上水、回水分隔总阀;和每一路切断阀,泄掉地热系统
内部残余压力;
2. 连接脉冲导入管,将脉冲清洗机(脉冲输出口)与分水器上水总承
堵头端连接;
3. 连接输水管,将水源和脉冲冲清洗机(入水口)连接;
4. 连接输气管,将您的空气压缩机出气口和脉冲清洗机(进气口)连
接;
5. 连接排污管,一端连接分水器上水堵头端,将另一端插入地漏。
(所
有连接必须牢固可靠)
(二) 启动、清洗
1. 接好空气压缩机和脉冲清洗机电源,按下脉冲清洗机上启动开关,
启动压缩机使其工作达到额定压力0.6个压以上(不同款机型操作
不一样);在脉冲调节器左部设置5,右部设置20.
2. 打开系统供水阀和压缩机输出开关;
3. 调节系统压力调节阀在系统压力表显示在4bar或0.4Mpa,打开系
统开关(遥控或手动);
4. 打开分水器上一个分隔阀,其它分隔阀关闭,观察回水管水流情况,
当有水气回流说明管道通常可以进行下一步清洗,(如果没有水流
则说明管道可能堵塞,需要先疏通管道);
4. 开始清洗,调节系统调节阀使压力提高到6bar,加大脉冲调剂器左
部数值,降低右部数值,遥控或手动启动设备,一直到排污管流出
的是清水清洗完毕。
5. 调节压力阀使压力到0.4bar,打开下一路分隔阀关闭清洗完的那一
路分隔阀进行清洗。
以此类推进行每一路的清洗;
6. 当每个单路清洗完毕后再把所有分隔阀全部打开进行整体清洗,直
至清洗干净为止,以见到清水为标准;
7. 确认清洗干净后,关闭进水阀和空气压缩机,利用罐内的余气将管
路中的残水排除干净。
(三) 系统恢复
1. 切断空气压缩机和脉冲清洗机的电源;
2. 将连接管分别解下;
3. 打开分水器上水、回水分隔总阀;
4. 将分水器恢复到洗前状态;
七、注意事项:
1. 各连接部位一定拧紧,防止泄露,连接时一定把管插到底,拆卸时
一定要把卡环压到底;
2. 排污端一定插入下水道口内,防止排污时污染环境;
3. 清洗时要时时注意:如脉冲清洗机和空气压缩机工作正常排污管没
有污水排出说明管路有堵塞,要停止工作,分析原因;
4. 脉冲清洗机发现有气、水泄露请停止工作,马上和客服联系进行维修或更换;
5. 空气压缩机的工作压力不得超过0.6个压:如果压力过高会造成老
化或者质量不好管道破裂和一定程度的损坏;
6. 冬季施工,为防止户外运输过程中机器内部管件发生冻结冻裂,请
在施工完毕后将清洗机内部残水扫净。