压力表缓冲管型号表

压力表缓冲管型号表

技术参数:

此缓冲管材质为无缝碳钢材质,适用于Y100大小的压力表。螺纹为:M20*。

缓冲管概述:

压力表弯管又叫压力表缓冲管或冷凝管,是用来连接压力表与压力表测量的设备或管道之间的配件,用来缓冲被测量介质对压力表弹簧管的瞬时冲击,同时可降低被测介质的温度,是对压力表进行保护的装置。压力表冷凝圈的形式有:O形、U形等;接头有:M20*2、M14*4、G1/2-G1/2等。广泛适用于啤酒、饮料、食品、造纸、制药、装饰等行业的设备、工艺管道上要求对流体压力进行测量的场合。

压力表缓冲管

[1]压力表缓冲管又叫压力表弯管或冷凝管,是用来连接压力表与压力表测量的设备或管道之间的配件,用来缓冲被测量介质对压力表弹簧管的瞬时冲击,同时可降低被测介质的温度,是对压力表进行保护的装置。压力表缓冲管的形式有:O形、U形等;接头有:M20*2、M14*4、G1/2-G1/2等。广泛适用于啤酒、饮料、食品、造纸、制药、装饰等行业的设备、工艺管道上要求对流体压力进行测量的场合。技术要求:最高工作压力: 最高工作温度:400°C 材质:321、304、304L、316、316L 标准:GB12459-90、DIN、JIS

压力表设定汇总20171215

1.ISE80/ZSE80(H)(F)-02-*-N/P/A/B/R/T/S/V-*-*(-0.1~2MPA) (1) 1.1型号选型说明 (1) 1.2配线说明选型说明 (2) 1.3设置方法 (4) 1.4功能设置 (6) 1.4.1开机时,同时按下上下键,可设置可校零? (6) 2.设置说明ISE30A-01-P (-0.1~1MPA)ISE30AF-01-N (-0.1~1MPA) (8) 3.20161214 艾可迅315T 型号:ISE80H-02-B (10) 3.120170217 艾可迅315T 型号:ISE80H-02-V (11) 4.20140716调试宇诠20T 型号:ISE30A-01-P? (12) 5.20170825 莘翔3000T 抽真空检测用,最大气压2KG 型号:DPSP1 (12) 6.20150606 安徽3台气压数显表设定; X-DSW气压数显表设定参考 (17) 7.比例阀ITVX2030-343BL3迪诺克70T 艾可迅315T (20) 8.SKON数字式压力表设定 (27) 9.20171214 天瑞自动取料机,抽真空气源气压检测 (28) 气压表型号:DPSN1-1020 (28) 10.20171214 天瑞自动取料机,抽真空数字显示气压表型号ZSE30A-01-P (31) 11.最后一页 ..................................................................................................................................................................................... 错误!未定义书签。 1. ISE80/ZSE80(H)(F)-02-*-N/P/A/B/R/T/S/V-*-*(-0.1~2MPA) 1.1 型号选型说明

压力表型号含义

YTP代表隔膜压力表,YMF代表法兰式,YML代表螺纹式 压力表,型号为Y-100,,级,径向G1/2A。 普通压力表,直径100mm,压力值,(16公斤力/平方厘米),接头方向---径向,接头螺纹---1/ 2"(管螺纹) 通用的意义有这些,但具体到不同的厂家还有不同的含意 在仪表型号表示中:Y表示压力,Z表示真空或阻尼,B表示防爆或标准,J表示精密或矩形,A表示氨表,X表示信号或电接点,XC表示磁助电接点,P表示膜片,E表示膜盒,F表示防腐,N表示耐震,T表示弹簧管,B表示不锈钢等等. 我们常用的有:YTF表示不锈刚压力表,YA表示氨用压力表,YXC表示电接点压力表,YZ表示真空压力表,YY表示乙炔压力表,YO表示耐热压力表,YH表示氢气压力表等等 YQ、YQF系列两级压力调节器主要适用于输入压力需要精密控制和调整的分析仪器、环保仪器设备、电力工业、以及其它仪器和设备.还适用于无腐蚀性(YQ系列)或有腐蚀性(YQ F系列)的纯气及标准混合气体,对钢瓶气体的高压气源进行精密调节后,送入仪器设备。主要技术参数: 1、型号及参数技术参数/型号YQ-1YQ-2YQ-3YQ-4YQ-5 YQF-1YQF-2YQF-3YQF-4YQF-5 输入压力表量程(Mpa)0~250~250~250~250~25 输出压力表量程(Mpa)0~~~40~~1 压力表等级 输入压力(Mpa)≤≤≤≤≤ 输出压力(Mpa)≤≤≤3≤≤ 额定流量(m3/h)、稳定性:气源压力在5~15MPa范围内,进口压力每变化1MPa,出口压力的变化不大于7*10-4MPa 3、流量特性:在进口压力大于2MPa时,调节流量在额定范围内变化,输出压力变化不大于输出压力表测量上限时的6% 4、安装连接: a.入口端:G5/8"(左、右旋),牙寸(左、右旋) b.出口端:M10*1;M8*1软管接头等. 三、适应气体: YQ系列 H2、O2、N2、CH4、CO、CO2、He、Ne、Ar等非腐蚀性气体 YQF系列 NH3、SO2、H2S、HCL、NO等腐蚀性气体. 产品名称:丙烷压力表产品型号:YW-60 产品名称:氩气表产品型号:Yar-60/100 产品名称:氢气压力表产品型号:YQ-60 产品名称:乙炔压力表产品型号:YY-60/100/150 产品名称:二氧化碳表产品型号:YC-60/100

压力表的型号规格定义解析

压力表的型号规格定义解析 压力表型号规格 我们常用的有:YTF表示不锈刚压力表'),YA表示氨用压力表'),YXC表示电接点压力表'),YZ表示真空压力表'),YY表示乙炔压力表'),YO表示耐热压力表'),YH表示氢气压力表')等等 压力表通用的意义有这些,但具体到不同的厂家还有不同的含意 在仪表型号表示中: Y表示压力, Z表示真空或阻尼, B表示防爆或标准, J表示精密或矩形, A表示氨表, X表示信号或电接点, XC表示磁助电接点, P表示膜片, E表示膜盒, F表示防腐, N表示耐震, T表示弹簧管, B表示不锈钢等等. YQ、YQF系列两级压力调节器主要适用于输入压力需要精密控制和调整的分析仪器、环保仪器设备、电力工业碳硫分析仪、炉前分析仪以及其它仪器和设备.还适用于无腐蚀性(YQ系列)或有腐蚀性(YQF系列)的纯气及标准混合气体,对钢瓶气体的高压气源进行精密调节后,送入仪器设备。 主要技术参数: 1、型号及参数技术参数/ 型号YQ-1 YQ-2 YQ-3 YQ-4 YQ-5 YQF-1 YQF-2 YQF-3 YQF-4 YQF-5 输入压力表量程(Mpa)0~25 0 ~25 0~25 0~25 0~25 输出压力表量程(Mpa)0~0.6 0~0.16 0~4 0~0.25 0~1 压力表等级2.5 2.5 2.5 2.5 2.5 输入压力(Mpa)≤18.5 ≤18.5 ≤18.5 ≤18.5 ≤18.5 输出压力(Mpa)≤0.45 ≤0.12 ≤3 ≤0.2 ≤0.75 额定流量(m3/h)0.6 0.06 1 0.2 0.6 2、稳定性:气源压力在5~15MPa范围内,进口压力每变化1MPa,出口压力的变化不大于7*10-4MPa 3、流量特性:在进口压力大于2MPa时,调节流量在额定范围内变化,输出压力变化不大于输出压力表测量上限时的6% 4、安装连接: a.入口端:G5/8"(左、右旋),W21.85 14牙寸(左、右旋) b.出口端:M10*1; M8*1软管接头等. 压力表是指以弹性元件为敏感元件,测量并指示高于环境压力的仪表。

PDS中文选型样本2013版

PDS 变送器选型目录 简介 (1) 工作原理 (6) PDS403 压力变送器 (10) PDS413 压力变送器(造纸型) (14) PDS423 压力型绝对压力变送器 (18) PDS433 差压型绝对压力变送器 (22) PDS443 差压变送器 (26) PDS453 高静压差压变送器 (30) PDS463 液位变送器(平膜片型) (34) PDS464 液位变送器(凸膜片型) (39) PDS473 远传压力变送器 (平膜片型) (44) PDS474 远传压力变送器 (凸膜片型) (49) PDS475 远传绝对压力变送器(平膜片型) (54) PDS476 远传绝对压力变送器(凸膜片型) (59) PDS483 远传差压变送器(平膜片型) (64) PDS484 远传差压变送器(凸膜片型) (69) PDS485 远传差压变送器(一平一凸膜片型) (74) PDS493 微差压变送器 (80) SIC-H375 HRAT 协议手持通信器 (84) 电气接头及安装尺寸 (87) 过程接头外形及安装尺寸 (88) 三阀组安装尺寸 (89) 防腐介质参考表 (90)

简介 产品背景 PDS 智能压力变送器由重庆川仪自动化股份有限公司引进国外顶尖设计技 术和制造技术研制的高性能智能压力变送器。该产品使用世界上先进的复合微硅 固态传感器,高可靠性的电子模块化设计以及精密的温度补偿及线性补偿系统, 确保了产品的精度、长期稳定性。 完美的智能诊断及仿真,高达14种的本机功能设定,多种可选的通讯协议,规格齐全的接液部分材质,高指标的电磁兼容及雷电保护特性等,使PDS智能 压力变送器自推出市场以来,受到国内外客户的一致好评。在电力、冶金、化工、石油、建材、 轻工、核电等行业得到了广泛的应用。 品质卓越 基本精度优于 0.074% 量程比 100:1 量程范围:差压 100Pa-3MPa;表压 1KPa-40MPa 输出信号:4-20mA 叠加 HART 协议或 PROFIBUS-PA 协议 过载极限:42MPa 静压影响:≤0.15%/10MPa 温度范围:环境温度-40~85℃;介质温度-40~300℃ (特殊制作-90~400℃) 长期漂移:≤0.1%/5 年 温度影响:≤(0.08·r+0.1)%(-10~60℃) 防爆:本安型 Ex ia IIC T6;隔爆型 Ex d IIC T6 防护等级:IP67 电源:10.5~45 V DC MTBF:435 年

常用压力表规格型号

常用压力表规格型号 名称型号结构测量范围/MPa 精度等 级 普通弹簧管压力表 Y-60径向 -0.1~0,0~0.1,0~0.25, 0~0.4,0~0.6,0~1,0~1.6, 0~2.5,0~4,0~6 2.5 Y-60T径向带后边 Y-60Z轴向无边 Y-60ZQ轴向带前边 Y-100径向-0.1~0,-0.1~0.06, -0.1~0.15,-0.1~0.3, -0.1~0.5,-0.1~0.9, -0.1~1.5,-0.1~2.4, 0~0.1,0~0.16,0~0.25, 0~0.4,0~0.6,0~1,0~1.6, 0~2.5,0~4,0~6 1.5 Y-100T径向带后边 Y-100TQ轴向带前边 Y-150径向 Y-150T径向带后边 Y-150TQ轴向带前边 Y-100径向 0~10,0~16,0~25,0~40, 0~60 Y-100T径向带后边 Y-100TQ轴向带前边 Y-150径向 Y-150T径向带后边 Y-150TQ轴向带前边 电接点压力表 YX-150径向-0.1~0.1,-0.1~0.15, -0.1~0.3,-0.1~0.5, -0.1~0.9,-0.1~1.5, -0.1~2.4,0~0.1,0~0.16, 0~0.25,0~0.4,0~0.6,0~1, 0~1.6,0~2.5,0~4,0~6 1.5 YX-150TQ轴向带前边 YX-150A径向 0~10,0~16,0~25,0~40, 0~60 活塞式压力计YS-2.5台式-0.1~0.25 0.02 0.05 YS-6台式0.04~0.6 YS-60台式0.1~6 YS-600台式0~60

压力表使用方法

1.概要 单体柱工作阻力检测仪是一种检测单体液压支柱初撑力(工作阻力)的仪器。他具有体积小、重量轻、便携带、便操作等优点,尤其是工艺结构设计的合理,这在同类产品中是不可媲美的,深受操作者的青睐。该产品成本低,适合于高档普采工作面批量装备日常携带检测,是单体液压支柱支护质量日常检测,确保高效安全生产的理想产品。 单体柱工作阻力检测仪主要是由表头U型卡、测体、顶针和压杆组成。使用时先将U型卡套在三用阀上,再将测体口插入U 型卡上,旋转U型卡,使测体口与三用阀吻合在一起,然后稍加用力旋转压杆,并压下压杆,此时顶针恰好打开三用阀内的球形单向阀,使支柱内液体压力等值地沿测体内顶针周边传入压力表,即可从表头上读出支柱的初撑力(工作阻力)值。 2.主要技术指标: 2.1 量程: 0-40/60Mpa 2.2 精度: 2.5%F/S 2.3 显示方式: 微表式 3.使用注意事项与维护 3.1 使用前应检查测体口内橡胶垫圈是否平整,如安放不平整 易从测体口处向外泄液; 3.2 从顶针后端泄液系“O”型密封圈损坏变形,这时可拆下压杆,将顶针从尾部拉出,更换“O”型密封圈;

3.3 表头泄液可用6#小梅花扳手上紧表头; 3.4如表头无压力显示,有几种可能:一是由于压力表拧得过紧使密封圈变形堵塞,阻止了液体压力传递。这时可拆下表头及防护罩更换密封圈。另一种可能是由于顶针长度不够,或顶针与三用阀配合不好,打不开三用阀,这时请与我们联系更换顶针。顶针长度不够是由于三用阀规格不同造成。因此,定货时最好事先说明三用阀规格(如:是否是防飞安全三用阀等);还有一种可能是由于枪口平垫与顶针配合过紧,可反复用力压动压杆,直至压力表显示压力; 3.5 旋转压杆时不要十分用力(只需稍加用力),以免损坏压杆; 3.6 表头表针不回零位,并不影响测量精度,这主要是由于测体内液体涨力造成; 3.7 顶针应定期拆下擦抹黄油,以防锈蚀。 4.配件 4.1 平垫:21×2 4.2 “O”型密封圈:Φ8×1.9 5.售后服务 产品自出厂之日起,一年内如出现非使用不当而引起的质量问题,我厂实行三包,一年后如出现问题,我厂亦可负责处理,并收取相应成本。

压力表型号与规格

压力表型号 在仪表型号表示中:Y表示压力,Z表示真空或阻尼,B表示防爆或标准,J表示精密或矩形,A表示氨表,X表示信号或电接点,XC表示磁助电接点,P表示膜片,E表示膜盒,F表示防腐,N表示耐震,T表示弹簧管,B表示不锈钢等等. 我们常用的有:YTF表示不锈刚压力表 ') ,YA表示氨用压力表 ') ,YXC表示电接点压力表 ') ,YZ表示真空压力表 ') ,YY表示乙炔压力表 ') ,YO表示耐热压力表 ') ,YH表示氢气压力表 ') 等等 YQ、YQF系列两级压力调节器主要适用于输入压力需要精密控制和调整的分析仪器、环保仪器设备、电力工业、以及其它仪器和设备.还适用于无腐蚀性(YQ系列)或有腐蚀性(YQF系列)的纯气及标准混合气体,对钢瓶气体的高压气源进行精密调节后,送入仪器设备主要技术参数: 1、型号及参数技术参数 / 型号 YQ-1 YQ-2 YQ-3 YQ-4 YQ-5 YQF-1 YQF-2 YQF-3 YQF-4 YQF-5 输入压力表量程(Mpa) 0~25 0 ~25 0~25 0~25 0~25 输出压力表量程(Mpa) 0~0.6 0~0.16 0~4 0~0.25 0~1 压力表等级 2.5 2.5 2.5 2.5 2.5 输入压力(Mpa)≤18.5 ≤18.5 ≤18.5 ≤18.5 ≤18.5 输出压

力(Mpa)≤0.45 ≤0.12 ≤3 ≤0.2 ≤0.75 额定流量(m3/h) 0.6 0.06 1 0.2 0.6 2、稳定性:气源压力在5~15MPa范围内,进口压力每变化1MPa,出口压力的变化不大于7*10-4MPa 3、流量特性:在进口压力大于2MPa时,调节流量在额定范围内变化,输出压力变化不大于输出压力表测量上限时的6%。 4、安装连接: a.入口端:G5/8"(左、右旋),W21.85 14牙寸(左、右旋) b.出口端:M10*1; M8*1软管接头等. 三、适应气体: YQ系列 H2、O2、N2、CH4、CO、CO2、He、Ne、Ar等非腐蚀性气体 YQF系列 NH3、SO2、H2S、HCL、NO等腐蚀性气体. 产品名称:丙烷压力表产品型号: YW-60 产品名称:氩气表产品型号: Yar-60/100 产品名称:氢气压力表产品型号: YQ-60 产品名称:乙炔压力表产品型号: YY-60/100/150 产品名称:二氧化碳表产品型号: YC-60/100 产品名称:氧气压力表产品型号: YO-60/100/150

一般压力表螺纹规格

GB/T1226-2001《一般压力表》国家标准中规定,Y-40压力表的连接螺纹为M10×1,Y-60压力表的连接螺纹为M14×1.5,Y-100,150,200,250压力表的连接螺纹为M20×1.5。在用户无特殊要求的情况下,制造商将按标准规定提供相应螺纹规格的压力表。 BS EN837-1 Pressure Gauges 压力表欧标中规定,螺纹接头有G1/8B,G1/4B,G3/8B,G1/2B四种管螺纹和1/8-27NPT EXT,1/4-18NPT EXT,1/2-14NPT EXT三种锥管螺纹,其中G3/8B为不推荐规格。实际上,R1/8(ZG1/8),R1/4(ZG1/4),R1/2(ZG1/2)也是压力表常用的连接螺纹规格

老国标的安装方式只有:径向直接式(I)、径向凸装式(Ⅱ)、轴向嵌装式(Ⅲ)、轴向直接式(Ⅳ)。见下表和图 型式安装方式接头位置外壳公称直径 I径向直接式径向40;60;100;150;200;250Ⅱ径向凸装式径向60;100;150;200;250 Ⅲ轴向嵌装式轴向60;100;150;200;250 Ⅳ轴向直接式轴向40;60

3.仪表精度等级的变化 压力表国家标准《一般压力表》GB/T1226-2001中第4.2 仪表的精确度等级: 仪表的精确度等级分为:1.0级;1.6级;2.5级;4.0级。各等级仪表的外壳公称直径应符合表2的规定。 表2 外壳公称直径(mm)精确度等级(%) 40;60 2.5;4.0 100 1.6;2.5 150;200;250 1. 0;1. 6 老国标的精度等级规定见下表 外壳公称直径(mm)精确度等级(%) 40;60 2.5;4.0 100 1.5;2.5 150;200;250 1. 0;1. 5 精度等级新旧国标的不同点是把原有的1.5级改为1.6级。 4.一般压力表按基本参数的分类。 1).仪表外壳公称直径(mm)系列:Φ40、Φ60、Φ100、Φ150、Φ200、Φ250. 2).仪表测量范围的上限(MPa)应符合规定的系列:1×10n、1.6×10n、2.5×10n、4×10

压力表说明书

3. Operating elements Barksdale GmbH Dorn-Assenheimer Strasse 27 D-61203 Reichelsheim / Germany Tel.: +49 - 60 35 - 9 49-0 Fax: +49 - 60 35 - 9 49-111 and 9 49-113 e-mail: info@barksdale.de www.barksdale.de UDS 3 8-digit 14-segment display Cover screws Sign T rend arrows Menu buttons 20-part bargraph optional Pg 13,5 Pressure conn. Pg 13,5 Pressure conn. 4 x ?4,5 38,5 Switchpoint display SP1...SP4 Dimensions (in mm) 1. Product description 2. Starting operations Intended applications -The pressure switch / trip amplifier is a device to monitor system pressure, temperature, flow, level, etc. and has four switching outputs and one analog output. -The pressure switch is only to be installed in systems where the maximum pressure Pmax is not exceeded (according to the values on the type label). -The trip amplifier is only to be connected to input signals according to the values on the type label at the bottom side of the device. -Attention: This device is not designed to be used as the only safety relevant element in pressurized systems according PED 97/23/EC. Only assemble or disassemble the device when depressurized! -The pressure switch should be installed and operated only by authorized personel. -For wall mounting remove the four front cover screws and the front cover. Then fasten the device with four screws to the wall and finally remount the front cover. T o damp strong vibrations shock mounts must be used. -Mount the pressure connection (G 1/4 female) of the UDS 3 to the pressure system with a flexible pipe and tighten with a 45 Nm torque. For pressure peaks damping screws must be used. -UAS 3: Connect the sensor to the 3-pin cube plug at the bottom side of the device. -The electrical connection (supply, analog output switching contacts) must be carried out according to the connection tables depicted on the top of the device by removing the cover cap and insert the cable through the cable gland PG 13,5. If required, additional cable glands can be installed in the cover cap by breaking out the perforated cavities. -The electrical connection must be carried out in accordance with the VDE 0100 regulations. In order to ensure trouble-free operation it is essential to connect the protective lead. When operating from 230 V AC loads at the switch contacts independent cables must be installed for supply and switches (cover cap with two cable screw connections). -If inductive loads (magnets, contactors, etc.) are connected to the switch relays, suitable protective devices (varistors etc.) must be provided. Item-Nr.: 923-1196 Software version: V1. or higher Index C, 05. 05. 2004 Specifications are subject to changes without notice. Plug 3-pin DIN 43650 38,5

压力表型号规格

压力表型号含义解析 通用的意义有这些,但具体到不同的厂家还有不同的含意 在仪表型号表示中:Y表示压力,Z表示真空或阻尼,B表示防爆或标准,J表示精密或矩形,A表示氨表,X表示信号或电接点,XC表示磁助电接点,P表示膜片,E表示膜盒,F表示防腐,N表示耐震,T表示弹簧管,B表示不锈钢等等. 我们常用的有:YTF表示不锈刚压力表') ,YA表示氨用压力表') ,YXC表示电接点压力表') ,YZ表示真空压力表') ,YY表示乙炔压力表') ,YO表示耐热压力表') ,YH表示氢气压力表') 等等 YQ、YQF系列两级压力调节器主要适用于输入压力需要精密控制和调整的分析仪器、环保仪器设备、电力工业、以及其它仪器和设备.还适用于无腐蚀性(YQ系列)或有腐蚀性(YQF 系列)的纯气及标准混合气体,对钢瓶气体的高压气源进行精密调节后,送入仪器设备。 主要技术参数: 1、型号及参数技术参数/ 型号YQ-1 YQ-2 YQ-3 YQ-4 YQ-5 YQF-1 YQF-2 YQF-3 YQF-4 YQF-5 输入压力表量程(Mpa)0~25 0 ~25 0~25 0~25 0~25 输出压力表量程(Mpa)0~0.6 0~0.16 0~4 0~0.25 0~1 压力表等级2.5 2.5 2.5 2.5 2.5 输入压力(Mpa)≤18.5 ≤18.5 ≤18.5 ≤18.5 ≤18.5 输出压力(Mpa)≤0.45 ≤0.12 ≤3 ≤0.2 ≤0.75 额定流量(m3/h)0.6 0.06 1 0.2 0.6 2、稳定性:气源压力在5~15MPa范围内,进口压力每变化1MPa,出口压力的变化不大于7*10-4MPa 3、流量特性:在进口压力大于2MPa时,调节流量在额定范围内变化,输出压力变化不大于输出压力表测量上限时的6%

压力表量程的选择说明

压力表量程的选择 1、为了保证压力表弹性元件能在弹性变形的安全范围内可靠地工作,压力表量程的选择不仅要根据被测压力的大小,而且还应考虑被测压力变化的速度,其量程需留有足够的余地。使用压力表测量稳定压力时,最大工作压力不应超过量程的2/3; 2、使用压力表测量脉动压力,最大工作压力不应超过量程的1/2; 3、使用压力表测量高压时,最大工作压力不应超过量程的3/5。为了保证测量准确度,最小工作压力不应低于量程的1/3。按此原则,根据被测最大压力算出一个数值后,从压力表产品目录中选取稍大于该值的测量范围。 4、应根据锅炉工作压力来选择,量程刻度的极限值应为工作压力的~倍,最好是2倍。在工业锅炉中,实际情况是锅炉实际运行时的工作压力总是比铭牌上的额定压力要低,工业蒸汽锅炉和热水采暖锅炉均是如此。例如4t/h的蒸汽锅炉,额定压力为1MPa,制造厂如按倍来配备压力表,应配备量程压力表。若用户由于生产工艺需要,实际运行在0.5MPa压力下即能满足工艺要求,这时运行量程,压力表的指针就指在量程的三分之一不到的位置,指针转过的角度很小.即选用的压力表量程太大。 热水锅炉亦是如此,例如采暖锅炉额定压力为0.7MPa,配备压力表应为1MPa或,如配备1MPa的压力表,怕在水压试验时使压力表过载,于是便配备量程为1.6MPa的压力表。实际运行时,只要0.2MPa就能满足采暖要求,压力表的指针指在量程八分之一的位置,很难使人相信压力表的准确性和灵敏性。 5、为解决上述问题,应采用两种压力表,即在水压试验时,采用锅炉厂按额定压力配备的压力表; 6、在日常运行时按实际工作压力的2倍来配备压力表。如工作压力为,即配用量程的压力表。这样指针在刻度盘中间位置,垂直向上。安全阀的起座压力也是按工作压力来调整,压 力表仍有足够的裕度应付超压指示。

压力表培训知识

压力的常识 一.压力概念:这里的压力概念,实际上指的是物理学上的压强,即单位面积上所承受压力的大小。 二.压力的两种表示方法: (1)绝对压力:以绝对真空为基准,高于绝对真空的压力; (2)相对压力:以大气压力作为基准所标示的压力。 绝对压力=大气压力+相对压力 三.名称 正压:以大气压力为基准,高于大气压力的压力。 负压(真空):以大气压力为基准,低于大气压力的压力。 差压:两个压力之间的差值。 表压:以大气压力为基准,大于或小于大气压力的压力。 压力表:以大气压力为基准,用于测量小于或大于大气压力的仪表。四.常用单位:帕(Pa)千帕(Kpa)兆帕(Mpa巴(Bar) 1Mpa=1000000Pa=10Bar 压力表的精度等级是反映压力表与标准仪表进行对比中, 指示值与真实值接近的准确度. 压力表的精度等级等于最大基本误差与测量上限之比值 的百分数.

习惯上去掉“ %符号,只将表示精确度等级的数字用“ O括起来。 压力表 一.概念以大气压力为基准,用于测量小于或大于大气压力的仪表。 二.分类 1.压力表按其测量精确度,可分为精密压力表、一般压力表。2.压力表按其指示压力的基准不同,分为一般压力表、绝对压力表、差压表。 3.压力表按其测量范围,分为真空表、压力真空表、微压表、低压表、中压表及高压表。 4.压力表按其组成,液柱式,电子式和机械式。本部分就机械式做以介绍。 三.机械式压力表 在工业过程控制与技术测量过程中,由于机械式压力表的弹性敏感元件具有很高的机械强度以及生产方便等特性,使得机械式压力表得到越来越广泛的应用。 (1)组成 弹性敏感元件齿轮传动机构指针外壳等

压力表选型手册

淮安华立仪表有限公司

Y-B1 Y-M3 Y-M8 YPF10 YXC12 YXC15 YTZ-15017 YN YN-B18 YE-100B20 YE-10015021 YT22 YA-10015023 Y24 YSG-2.326

Y-B ( ) MPa Y-60B Y-63B 0~0.6 1 1.6 2.5 4 6 10 16 25 40 60 -0.1~0.5 0.9 1.5 2.4 2.5 Y-100B Y-150B Y-103B Y-153B 0~0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 2 5 40 60 -0.1~0 0.06 0.15 0.3 0.5 0.9 1.5 2.4 1.5

:5-55 ( ); -25~55 ( ); -40-70 ( ) : 0.4 10 ( 20 5 :V H 3( ); V H 4( ) :IP64

Y-60B Y-100B,Y-150B 0Cr18Ni9(304) 0Cr17Ni12Mo2(316) 1Cr18Ni9Ti 0Cr17Ni12Mo2(316) 1Cr18Ni9 Y B 60 100 150 60 100 150mm 63 103 153 60 100 150mm ( 63 ) Y- 60B Y- 63B D B 55 60 65 d( ) M14x1.5 1/4 (NPT) L 14 d 76 d 1 4.5 H 35 35 H 1 22 H 2 13 Y- 100B Y- 103B Y- 150B Y- 153B 100 150 90 90 120 95 M20x1.5 G3/8 1/2 3/8 1/2 (PT) 1/4 1/2 (NPT) 20 118 165 5.5 5.5 44 44 44 44 27 27 18 30 18 30

压力表使用规范

压力表使用规范(总7页) -CAL-FENGHAI.-(YICAI)-Company One1 -CAL-本页仅作为文档封面,使用请直接删除

压力表使用规范 为加强在用压力表的管理,确保压力表完好,规范压力表的使用,制定如下规定,望认真执行; 1. 压力表的选用 1.1 选用的压力表,应当与压力容器、管道内的介质相适应。 1.2 设计压力小于1.6MPa压力容器、管道使用的压力表精度(注1)不得低于 2.5级;设计压力大于或者等于1.6MPa压力容器、管道使用的压力表精度不得低于1.6级。 1.3 工艺用压力表(注2)表盘刻度极限值应为最大允许工作压力(注3)的1.5-3.0倍,最好取2倍左右。在满足工艺要求的条件下优先选用外壳公称直径100mm的压力表(很重要)。---压力表选型依据 1.4 压力表在测量稳定负荷时不得超过量程的2/3,测量波动压力时,不应超过量程的1/2,至于最低压力,在以上两种情况下,均不应低于量程的1/3。---压力表选型依据 2. 压力表的校验 2.1 压力表安装前应进行校验,然后每隔半年校验一次。 2.2 需要强检的压力表由设备科负责外出校验,校验后的压力表应将检验标志贴在表盘上,并注明下次校验日期或有效期。 2.3 非强检的压力表可根据检定的压力表进行自校,并做好自校记录。 3. 压力表的安装要求 3.1 装设位置应便于操作人员观察和清洗,且应避免受到辐射热,冻结或振动的不利影响。

3.2 压力表与压力容器、管道之间,应装设三通旋塞或针型阀;三通旋塞或针型阀应有开启标记;压力表与压力容器、管道之间,不得连接其他用途的任何配件或接管。 3.3 用于蒸汽介质的压力表,在压力表与压力容器、管道之间应装有存水弯管。使蒸汽在这一段弯管内冷凝,以避免高温蒸汽直接进入压力表的弹簧管内,致使表内元件过热而产生变形,影响压力表的精度。存水弯管用钢管时,其内径应不小于10mm。 3.4 用于高温、具有腐蚀性或高粘度介质的压力表,在压力表与压力容器、管道之间应装设能隔离介质的缓冲装置。 3.5专用的特殊压力表,严禁他用,也严禁在没有特殊可靠的装置上进行测量,更严禁用一般的压力表作特殊介质的压力测量。 3.6 对于新购置的压力检测仪表,在安装使用之前,一定要进行计量检定,以防压力仪表运输途中震动、损坏或其它因素破坏准确度。 4.压力表的使用和更换 4.1在用压力表的切断阀必须呈打开状态(为了将压力表损坏造成的后果降到最低,切断阀可根据实际需要调整开度大小,但必须能使压力表显示正确压力)。 4.2压力表有下列情况之一时,应停止使用并更换。 4.2.1有限止钉的压力表, 在无压力时,指针不能回到限止钉处;无限止钉的压力表,在无压力时,指针距零位的数值超过压力表的允许误差. 4.2.2 表针指示超过最高量程的。 4.2.3 表盘封面玻璃破裂或表盘刻度模糊不清。 4.2.4 封印损坏或超过校验有效期限。

压力表附件使用说明

The information in this leaflet is give in good faith, but we reserve the right to make changes without notice. Pressure Gauge Valves According to DIN 16270, DIN 16271 with Male Test Connection, and with Test Flange 11200 12/01 ?Nominal Pressure: PN 250 for brass version, PN 400 for versions made of alloy steel or 316 stainless steel (1.4571) ? Body: moulded part when made of brass; drop forging when made of alloy steel or 316 stainless steel (1.4571) ?Surface: alloy steel browned ? Internally spindle thread ?Burnished valve spindel with movable rolled-in valve cone ?Version acc. to DIN 16270 Form A with adjusting nut Form B with turnable nut and fitting for gauge holder Special Versions ?Special packing for temperatures up to 250 °C (not with test flange)?Brass or stainless steel versions: free of oil and grease ?Test certificate acc. to EN 10 204 / 3.1. B for body material ?Pressure gauge valves similar to DIN 16270, but DVGW- registrated, PN 100, temperature limits -10 / +70 °C, sealing NBR ("Perbunan", ~bunaN), with holder for the sealing made of brass (brass and alloy steel versions) resp. 1.4571 (~ 316 Ti), brass version: adjusting nut brass, DVGW-tested following DIN 3537part 1, for all gaseous media acc. to DVGW-Work Sheet G 260 (not with test flange) ?Brass version ?" BSP, but for temperatures down to -20 °C (up to +120 °C), adjusting nut ?" BSP brass, union nut brass ?Others uponrequest Version acc. to DIN 16271male test connection M 20 x 1,5 ?Test flange in dependence of valve material made of brass, alloy steel or stainless steel 1.4571 (~ 316 Ti)?Sealing cap: for alloy steel and brass -versions made of alloy steel,for stainless steel version: 1.4571 (~ 316 Ti) Version similar to DIN 16271 ? Special Configurations see left side Form B with turnable nut and fitting for gauge holder Form A with adjusting nut Vent Screw with test flange 60 x 25 x 10 mm (2,36 x .98 x .39") Versions: Brass Alloy Steel Stainless Steel Components: Material (DIN material numbers): Body brass 1.0460 1.4571 Valve spindle 1.4104 Valve cone 1.4034 hardened Packing PTFE graphite PTFE Union nut alloy steel 1.4571 Adjusting nut Turnable nut brass alloy steel 1.4571 Vent screw 1.4104 1.4571 Hand wheel plastic Temperature rating -10 / + 120 °C (14 / 248 °F ) -10 / +120 °C (14 / 248 °F) -40 / +200 °C (-40 /+392 °F) :l a i r e t a M s s a r B l e e t S y o l l A l e e t S s s e l n i a t S : n o i s r e V A m r o f 17261N I D 5,1x 02M n o i t c e n n o c t s e t e l a m h t i w :d s n o i t c e n n o C e l a m e f P S B "?t u n g n i t s u j d a –e l a m P S B "?:e d o C -g n i r e d r O 300120-Z 300220-Z 300320-Z :d s n o i t c e n n o C e l a m e f 5,1x 02M t u n g n i t s u j d a –e l a m 5,1x 02M :e d o C -g n i r e d r O 3 20120-Z 3 20220-Z 3 20320-Z : n o i s r e V h t i w ,r e d l o h e g u a g r o f g n i t t i f h t i w B m r o f 17261N I D 5 ,1x 02M n o i t c e n n o c t s e t e l a m :d s n o i t c e n n o C e l a m e f P S B "?t u n e l b a n r u t –e l a m P S B "?:e d o C -g n i r e d r O 3 10120-Z 3 10220-Z 3 10320-Z :n o i s r e V 1 7261N I D o t r a l i m i s m m 01x 52x 06e g n a l f t s e t h t i w :d s n o i t c e n n o C e l a m e f P S B "?t u n g n i t s u j d a –e l a m P S B "?: e d o C -g n i r e d r O 2 001202 002202 00320

压力表选型及规格型号介绍.docx

压力表选型及规格型号介绍

一、量程选择 在测稳定压力时,一般压力表最大量程选择接近或大于正常压力测量值的 1.5 倍; 在测脉动压力时,一般压力表最大量程选择接近或大于正常压力测量值的 2 倍; 在测机泵出口压力时,一般压力表最大量程选择接近机泵出口最大压力值 ; 在测高压压力时,一般压力表最大量程选择应大于最大压力测量值的 1.7 倍; 为了保证压力测量精度,最小压力测量值应高于压力表测量量程的1/3 二、型式选择 测压 >0.4MPa 时,可选用弹簧管压力表; 测压 <0.04MPa 时,可选用波纹管和膜盒压力表; 测粘稠、易结晶、腐蚀性、含固体颗粒的场合,可采用膜片压力表或附带化学密封装置 ; 测蒸汽或高于 60℃的介质压力测量应选择不锈钢压力表或安装冷凝圈 ; 脉动压力测量应附加阻尼器或耐震压力表 ; 测含有粉尘气体时应设置除尘器 ; 测含有液体的气体压力时应设置气液分离器;

测某些化工介质应选用专用压力表:对含氨介质压力测量采用氨用压力表,对含氧气压力测量采用氧气压力表,对乙炔压力测量采用乙炔压力表,对含硫介质压力采用抗硫压力表 ; 高压压力表 (大于 10MPa) 应有泄压安全设施。 压力真空表 YZ-50/60/75/100/150 压力真空表适用测量无爆炸,不结晶,不凝固,对铜和铜合 金无腐蚀作用的液体、气体的真空及压力。压力真空表既能测量真空, 同时能测量压力,广泛应用于石油、化工、冶金等工业。 型号命名: 技术参数: 型号结构形式精确度%测量范围MPa YZ-50Z轴向无边-0.1 ~0; -0.1~ ±2.5 YZ-60径向无边0.06 ;-0.1~0.15 ;

相关文档
最新文档