SelExam10-1.1
Belimo SH24A-MP300 通信式线性驱动器说明书
SH24A-MP300Communicative linear actuator adjustingdampers and slide valves in technical building installations• Actuating force 450 N• Nominal voltage AC/DC 24 V• Control modulating, communicative 2...10 V variable• Position feedback 2...10 V variable• Length of Stroke Max. 300 mm, adjustable in 20 mm increments• Communication via Belimo MP-Bus • Conversion of sensor signalsTechnical dataElectrical dataNominal voltageAC/DC 24 V Nominal voltage frequency 50/60 HzNominal voltage rangeAC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 3.5 W Power consumption in rest position 1.4 W Power consumption for wire sizing 6 VAConnection supply / control Cable 1 m, 4x 0.75 mm²Parallel operationYes (note the performance data)Data bus communicationCommunicative control MP-Bus Number of nodesMP-Bus max. 8Functional dataActuating force motor 450 NActuating force variable 25%, 50%, 75% reduced Operating range Y 2...10 V Input impedance100 kΩOperating range Y variable Start point 0.5...30 V End point 2.5...32 V Operating modes optionalOpen/close3-point (AC only)Modulating (DC 0...32 V)Position feedback U 2...10 V Position feedback U note Max. 0.5 mA Position feedback U variable Start point 0.5...8 V End point 2.5...10 V Position accuracy ±5%Direction of motion motor selectable with switchDirection of motion note Y = 0 V: with switch 0 (retracted) / 1 (extended)Direction of motion variable electronically reversible Manual override with push-button, can be locked Stroke300 mmLength of Stroke Max. 300 mm, adjustable in 20 mm incrementsStroke limitation can be limited on both sides with mechanical end stops Running time motor 150 s / 100 mm Running time motor variable 150...600 s / 100 mm Adaptation setting rangemanualSH24A-MP300Technical dataFunctional data Adaptation setting range variable No actionAdaptation when switched onAdaptation after pushing the manual overridebuttonOverride control MAX (maximum position) = 100%MIN (minimum position) = 0%ZS (intermediate position, AC only) = 50%Override control variable MAX = (MIN + 32%)...100%MIN = 0%...(MAX – 32%)ZS = MIN...MAXSound power level, motor52 dB(A)Safety data Protection class IEC/EN III, Safety Extra-Low Voltage (SELV)Power source UL Class 2 SupplyDegree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2Enclosure UL Enclosure Type 2EMC CE according to 2014/30/EUCertification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14UL Approval cULus according to UL60730-1A, UL60730-2-14and CAN/CSA E60730-1The UL marking on the actuator depends onthe production site, the device is UL-compliantin any caseHygiene test According to VDI 6022 Part 1 / SWKI VA104-01, cleanable and disinfectable, lowemissionType of action Type 1Rated impulse voltage supply / control0.8 kVPollution degree3Ambient humidity Max. 95% RH, non-condensingAmbient temperature-30...50°C [-22...122°F]Storage temperature-40...80°C [-40...176°F]Servicing maintenance-freeWeight Weight 1.3 kgSH24A-MP300•••••••••••Safety notesThis device has been designed for use in stationary heating, ventilation and air-conditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport.Outdoor application: only possible in case that no (sea) water, snow, ice, insolation or aggressive gases interfere directly with the device and that it is ensured that the ambient conditions remain within the thresholds according to the data sheet at any time.Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied with during installation.The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user.Cables must not be removed from the device.The rotary supports and coupling pieces available as accessories must always be used if transverse forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Installation notes»).If the actuator is exposed to severely contaminated ambient air, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rod from being extended and retracted correctly.If not installed horizontally, the maual override button may only be actuated when there is no pressure on the gear rod.To calculate the actuating force required for air dampers and slide valves, the specifications supplied by the damper manufacturers concerning the cross- section and the design, as well as the installation situation and the ventilation conditions must be observed.If a rotary support and/or coupling piece is used, actuation force losses are to be expected.The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed.Product featuresOperating modeConventional operation:The actuator is connected with a standard control signal of 0...10 V and drives to the position defined by the control signal. Measuring voltage U serves for the electrical display of the damper position 0...100% and as control signal for other actuators.Operation on Bus:The actuator receives its digital control signal from the higher level controller via the MP-Bus and drives to the position defined. Connection U serves as communication interface and does not supply an analogue measuring voltage.The actuator has a seal closing function. The mechanical end stop is actively approached as soon as the control signal < DC 2.1 V or > DC 9.9 V. As soon as the control signal is again > DC 2.2 V or < DC 9.8 V, the actuator drives to the position defined by the control signal in the adapted range.Converter for sensorsConnection option for a sensor (passive or active sensor or switching contact). The MPactuator serves as an analogue/digital converter for the transmission of the sensor signal via MP-Bus to the higher level system.Parametrisable actuators The factory settings cover the most common applications. Single parameters can be modified with the Belimo service tools MFT-P or ZTH EU.Simple direct mountingThe actuator can be directly connected with the application using the enclosed screws. The head of the gear rod is connected to the moving part of the ventilating application individually on the mounting side or with the Z-KS1 coupling piece provided for this purpose.Manual overrideManual override with push-button possible (the gear train is disengaged for as long as the button is pressed or remains locked).SH24A-MP300Adjustable strokeIf a stroke limitation will be adjusted, the operating range on this side of the gear rod can be used starting with an extension length of 20 mm and then can be limited respectively in increments of 20 mm by means of the mechanical end stops Z-AS1.High functional reliabilityThe actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached.Home positionThe first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. The synchronisation is in the home position (0%).The actuator then moves into the position defined by the control signal.Adaptation and synchronisationAn adaptation can be triggered manually by pressing the "Adaptation" button or with the PC-Tool. Both mechanical end stops are detected during the adaptation (entire setting range).Automatic synchronisation after pressing the manual override button is configured. The synchronisation is in the home position (0%).The actuator then moves into the position defined by the control signal.A range of settings can be adapted using the PC-Tool (see MFT-P documentation)Product featuresAccessoriesGatewaysDescriptionType Gateway MP to BACnet MS/TP UK24BAC Gateway MP to Modbus RTUUK24MOD Electrical accessoriesDescriptionType Signal converter voltage/current 100 kΩ 4...20 mA, Supply AC/DC 24 V Z-UIC Positioner for wall mounting SGA24Positioner for built-in mounting SGE24Positioner for front-panel mounting SGF24Positioner for wall mountingCRP24-B1MP-Bus power supply for MP actuatorsZN230-24MP Mechanical accessoriesDescriptionType End stop kit, Multipack 20 pcs.Z-AS1Rotary support, for linear actuator, for compensation of transverse forcesZ-DS1Coupling piece M8Z-KS1ToolsDescriptionType Service tool, with ZIP-USB function, for parametrisable andcommunicative Belimo actuators, VAV controller and HVAC performance devicesZTH EUBelimo PC-Tool, Software for adjustments and diagnostics MFT-P Adapter for Service-Tool ZTHMFT-C Connecting cable 5 m, A: RJ11 6/4 ZTH EU, B: 6-pin for connection to service socketZK1-GEN Connecting cable 5 m, A: RJ11 6/4 ZTH EU, B: free wire end for connection to MP/PP terminalZK2-GENElectrical installationSupply from isolating transformer.Parallel connection of other actuators possible. Observe the performance data.SH24A-MP300 Wire colours:1 = black2 = red3 = white5 = orangeWiring diagramsMP-BusAC/DC 24 V, modulatingElectrical installationFunctionsFunctions with basic values (conventional mode)Override control with AC 24 V with relay contacts Override control with AC 24 V withrotary switchControl remotely 0...100% withpositioner SG..Minimum limit with positioner SG..Primary/secondary operation (position-dependent)Functions with basic values (conventional mode)Control with 4...20 mA via external resistorCaution:The operating range must be set to DC 2...10 V.The 500 Ohm resistor converts the 4...20 mA current signal to a voltage signal DC 2...10 V.Functional checkProcedure1. Connect 24 V to connections 1 and 22. Disconnect connection 3:– with direction of rotation L: Actuator rotates to the left – with direction of rotation R: Actuator rotates to the right3. Short-circuit connections 2 and 3:– Actuator runs in opposite directionFunctions with specific parameters (Parametrisation necessary)Connection on the MP-BusMP-Bus Network topologyMax. 8 MP-Bus nodesThere are no restrictions for the network topology (star, ring, tree or mixed forms are permitted).Supply and communication in one and the same 3-wire cable • no shielding or twisting necessary• no terminating resistors required•••••Functions with specific parameters (Parametrisation necessary)Connection of active sensorsConnection of external switching contactSupply AC/DC 24 VOutput signal 0...10 V (max. 0...32 V)Resolution 30 mVSwitching current 16 mA @ 24 VStart point of the operating range must be parametrised on the MP actuator as ≥0.5 VConnection of passive sensors1) Depending on the type 2) Resolution 1 OhmCompensation of the measured value is recommendedOverride control and limiting with AC 24 V with relay contactsControl open/closeSH24A-MP300Functions with specific parameters (Parametrisation necessary)Override control and limiting with AC 24 V with rotary switchControl 3-point with AC 24 VCaution:The "Close" function is only guaranteed if the start point of the operating range is definedas min. 0.5 V.FunctionsOperating controls and indicators1Direction of stroke switch Switch over:Direction of stroke changes2Push-button and LED display green Off:No power supply or malfunction On:In operationPress button:Triggers stroke adaptation, followed by standard mode3Push-button and LED display yellow Off:Standard modeOn:Adaptation or synchronisation process active Flickering:MP-Bus communication active Flashing:Request for addressing from MP client Press button:Confirmation of the addressing4Manual override button Press button:Gear train disengages, motor stops, manual override possible Release button:Gear train engages, synchronisation starts, followed by standard mode5Service plugFor connecting parametrisation and service tools Check power supply connection 2 Off and 3 OnPossible wiring error in power supplyInstallation notesIf a rotary support and/or coupling piece is used, losses in the actuation force losses are to be expected.SH24A-MP300Applications without transverse forcesThe linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve).Applications with transverse forcesThe coupling piece with the internal thread (Z-KS1) is connected to the head of the gear rod. The rotary support (Z-DS1) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw.Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilating application (e.g. damper or slide valve). The transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. The maximum permissible swivel angle of the rotary support and coupling piece is 10° (angle), laterally and upwards.Installation notesServiceTool connectionThe actuator can be parametrised by ZTH EU via the service socket.For an extended parametrisation the PC tool can be connected.Connection ZTH EU / PC-ToolDimensionsFurther documentation• Overview MP Cooperation Partners• Tool connections• Introduction to MP-Bus TechnologyApplication notes• For digital control of actuators in VAV applications patent EP 3163399 must be considered.。
SONIX 8位单片机 SN8P2711A 用户说明书
2.1.1.1 复位向量(0000H)........................................................................................................................................... 10
2.1.3 数据存储器(RAM) ................................................................................................................................................... 16
1.1
功能特性............................................................................................................................................................................. 6
目 录................................................................................................................................................................................................ 3
2.1.1.2 中断向量(0008H)........................................................................................................................................... 11
矽力杰产品选型_恒佳兴电子专业电源IC
Single output step down (Buck) Converter Vin max < 7VSY8018A 2.5 5.5 0.45 / 0.6 ±2% 1.5 400/200 √Ultra Low Quiescent Current DFN2x2-8 SY8030L 2.5 5.5 0.6 2.25 0.6 ±1.5% 50 300/200 DFN2x2-6 SY8078B 1.85 5.5 0.6 3 0.4 ±2% 40 350/250 DFN1.45x1-6 SY8010 2.5 5.5 1 1.5 0.6 ±1.5% 50 200/150 DFN2x2-6 SY8011A 2.5 5.5 1 1.5 0.6 ±2% 40 230/150 DFN1.5x1.5-6 SY8061A 2.5 5.5 1 1.5 0.6 ±2% 60 260/170 Auto Discharge DFN2x2-6 SY8065L 2.5 5.5 1 1.5 0.6 ±2% 90 250/200 √SOT 23-6 SY8071 2.5 5.5 1 2 0.6 ±2% 40 260/170 SOT 23-5 SY8075 2.5 6.5 1 1.5 0.6 ±2% 40 260/170 DFN2x2-6 SY8077 2.5 6.5 1 1.5 0.6 ±2% 40 260/170 SOT 23-5 SY8080 2.5 5.5 1 3 0.6 ±2% 40 270/160 SOT 23-5SY8081 2.5 5.51 2.5 0.6 ±2%40230/150 Output auto discharge DFN1.5×1.5-6SY8011B 2.5 5.5 1.5 1.5 0.6 ±2%60210/130 DFN1.5x1.5-6SY8030 2.5 5.5 1.5 2.25 0.6 ±1.5%50200/150 Ext Mode DFN2x2-6 SY8002B 2.7 5.5 1.5 1 0.6 ±2% / 110/80 √Latch off protection SOT 23-6SY8002E 2.7 5.5 2 1 0.6 ±2% / 110/80 √Force PWM SOT 23-6SY8003L 2.7 5.5 2 1 0.6 ±2% 55 120/90 √DFN2x2-8Single output step down (Buck) Converter Vin max < 7V±2%SY8089 SOT 23-52.7 5.5 2 1 0.6 55 110/80 Latch off protectionSY8003C1 2.7 5.5 3 3 0.6 ±2% 55 110/80 √DFN2x2-8SY8823 2.5 5.5 3.5 2 0.6 ±1.5% 18 55/35 √QFN2x1.5-8SY8047 2.5 5.54 1.25 0.6 ±1.5%1875/55√QFN3x3-16SY8856 2.7 5.54 3 0.6 ±1.5%6035/15 √√DFN2x2-8√±1.5%SY8003F 2.7 5.5 3 1 0.6 / 110/80 DFN2x2-8 SY8079P 2.7 6.5 0.6 ±2% 55 125/95 Non latch off OVP SOT 23-6SY8032 2.7 5.5 2.5 0.6 ±2% 80 100/80 SOT 23-6SY8032E 2.7 5.5 2.5 0.6 ±2% 100/80 Force CCM SOT 23-6SY8003 2.7 5.5 0.6 ±2% 55 110/80 Latch SCP/OVP DFN2x2-8SY8003A 2.7 5.5 0.6 ±2% 55 110/80 Non-latch off protection DFN2x2-8SY8003C 2.7 5.5 0.6 ±2% 55 100/80 DFN2x2-8 SY8003E 2.7 5.5 0.6 ±2% 110/80 Force CCM DFN2x2-8 SY8043A 2.7 5.5 1.25 0.6 ±2% 18 75/55 DFN3x3-16 SY8047L 2.5 5.5 1.25 0.6 ±2% 18 75/55 QFN3x3-16 SY8859 2.7 5.5 0.6 ±1% 40 100/50 OVP/OCP/SCP/UVLO/OTP QFN1.5x1.5-7Single output step down (Buck) Converter Vin max < 7VPart Number Vin (min)(V)Vin (max)(V)Iout (max) (A) Fsw (MHz)Vout (min)( V)VoltageAcurracySY8824B 2.6 5.5 4 1.8 / ±1% SY8824C 2.6 5.5 4 1.8 / ±1% SY8035 2.7 5.5 5 1 0.6 ±1.5% SY8805A 3 5.5 5 1 0.6 ±1.5% SY8825 2.5 5.5 5 2 0.6 ±1.5% SY8876 2.7 6.5 6 1.2 0.6 ±1.5% SY8827K 2.5 5.5 6 2.4 ±1.5% SY8868 2.7 5.56 10.6 ±1% SY8099 2.7 5.5 6 1 0.6 ±1% SY8812 2.75 5.5 12 1 ±1%80 70/40Programmable Output Voltage: 0.7625Vto 1.55V in 12.5mV/step; Default 1.15Voutput voltage8015010018606550408070/4050/4035/1555/3538/1528/1735/1530/1212/6PackageTSOT 23-8Programmable Output Voltage: 0.7625Vto 1.55V in 12.5mV steps; Default 1.05Voutput voltageTSOT 23-8EXT SS DFN3x3-10DFN2x2-8QFN2x1.5-8OCP/UVLO/OTP DFN2x2-8I2C Programmable Vout: 0.7125V~ 1.5V CSP1.56x1.96-20in 12.5mV steps, Addr: 1000001xCOT mode,max dutyHigh efficiencyP rogrammable Output Voltage: 0.6V to1.5V in 10mV stepsQFN2x2-10TSOT 23-6QFN3x3-12Dual output step down (Buck) Converter Vin max < 7VPart Number Vin(min)(V)Vin(max)(V)Iout(max)(A)Fsw (MHz) Vout (min)(V)VoltageAcurracyQuiescentCurrent(uA)MO SFET Ron H/L (m? ) Power GoodOutputFeature/ Special Function PackageSY8020 2.5 5.5 1A x2 1.5 0.6 ±2% 50 200/150 Individual EN DFN3x3-12 SY8831 2.5 5.5 1A x2 1.5 0.6 ±2% 45/55 260/180 Individual EN TSOT 23-8 SY8832 2.5 5.5 2A x2 2 0.6 ±2% 35/45 125/100 Individual EN TSOT 23-8 SY8024 3 5.5 3A x2 1 0.6 ±2% 80 105/85 Individual EN DFN3x3-12 SY8821 2.5 5.5 1A/1.5A 2 0.6 ±2% 45 125/100 Individual EN DFN2x1.5-8Single output step down (Buck) Converter, Vin max > 7VuiescentOriginal Part Number Vin(min)(V)Vin(max)(V)Iout(max)(A)Fsw (MHz) Vout( imn)(V)Fixed O utputVoltage(V)VoltageAcurracyCurrent (uA)MOSFET(RonH/L) (m ? )Power oGodOutputFeature/ Special Function PackageSY8290 5 40 0.3 2 0.6 ±2.0% 160 2000/- SOT 23-6 SY8200 6 24 0.6 0.5 0.6 ±2% 400 420/200 SOT 23-6 SY8401 4.5 50 0.8 1.2 0.6 ±1.0% 150 700/- SOT 23-6SY8201 4.527 1 0.5 0.6 ±2%400350/150 SOT 23-6SY8201C 4.527 1 1.15 0.6 ±2%400350/150 Force CCM SOT 23-6SY85017 100 1 0.2~1MHz 1.2 ±2.0%400500/240 Programmable Switching Frequency SO8ESY8291 5 40 1.2 0.8 0.6 ±2.0% 160 180/- SOT 23-6 SY8502 7 100 1.8 0.2~1MHz 1.2 ±2.0% 400 500/240 Programmable Switching Frequency SO8ESingle output step down (Buck) Converter, Vin max > 7VVin(min) Vin(max) Iout(max) Fsw Vout(min) Voltage Quiescent MO SFET(Ron Power GoodPart Number(V) (V) Iout((m A)ax)(MHz) (V) Acurracy Current (uA) H/L) (m ? ) O utputFeature/ Special Function PackageSY8121 4.5 18 2 1 0.6 ±2% 400 170/160 SOT 23-6/ DFN2x2-6 SY8121B 4.35 18 2 1.2 0.6 ±2% 170/160 1.2MHz, FCCM SOT 23-6SY8120B1 4.5 18 2 0.5 0.6 ±2% 400 130/120 SOT 23-6SY8121C 4.5 18 2 1.2 0.6 ±2% 400 130/120 SOT 23-6SY8222 4.5 23 2 0.5 0.6 ±1.5% 400 150/110 √EXT SS, Hic-cup SCP DFN3x3-10SY8292 5 40 2 0.8 0.6 ±2.0% 160 180/- SOT 23-6SY8113B 4.5 18 3 0.5 0.6 ±1.5% 100 80/40 Hic-cup SCP TSOT 23-6SY8113C 4.518 3 1 0.6 ±1.5%10080/40 Hic-cup SCP TSOT 23-6SY8113D 4.5 18 3 0.5 0.6 ±1.5% 100 80/40 √Hic-cup SCP, EXT SS TSOT 23-8SY8113G 4.518 3 0.5 0.6 ±1.5%10080/40 Hic-cup SCP, FCCM TSOT 23-6SY8203A 4.523 3 1 0.6 ±1.5%400120/85 √EXT SS DFN3x3-10SY8223 4.523 3 0.5 0.6 ±1.5%400120/85 √EXT SS, Hic-cup SCP DFN3x3-10SY8253 4.5 23 3 0.5 0.6 ±1.5% 100 105/50 √EXT SS, Hic-cup SCP TSOT 23-8SY8303 4.5 40 3 0.5~2.5MHz 0.6 ±1.5% 18 70/110 TSOT 23-8 SY8293 5 40 3 0.8 0.6 ±2.0% 160 180/-SO8EPart Number Vin(min)(V)Vin(max)(V)Iout(max)(A)Fsw (MHz) Vout(min)(V)VoltageAcurracyQuiescentCurrent (uA)MO SFET(Ron H/L)(m ? )Power Good OutputFeature/ Special Function PackageSY8502 7 85 1.2 0.2~0.5 1.2 ±2.0% / 500/240 Programmable Switching FrequencyRangeSO8ESY8120B1 4.5 18 2 0.5 0.6 ±2% 400 130/120 SOT 23-6SY8121 4.5 18 2 1 0.6 ±2% 400 170/160 SOT 23-6/ DFN2x2-6 SY8121C 4.5 18 2 1.2 0.6 ±2% 400 130/120 SOT 23-6SY8222 4.5 23 2 0.5 0.6 ±1.5% 400 150/110 √EXT SS, Hic-cup SCP DFN3x3-10SY8292 5 40 2 0.8 0.6 ±2.0% 160 180/- SOT 23-6SY8113B 4.5 18 3 0.5 0.6 ±1.5% 100 80/40 Hic-cup SCP TSOT 23-6SY8113C 4.5 18 3 1 0.6 ±1.5% 100 80/40 Hic-cup SCP TSOT 23-6SY8113D 4.5 18 3 0.5 0.6 ±1.5% 100 80/40 √Hic-cup SCP, EXT SS TSOT 23-8SY8113G 4.5 18 3 0.5 0.6 ±1.5% 100 80/40 Hic-cup SCP, FCCM TSOT 23-6SY8203A 4.5 23 3 1 0.6 ±1.5% 400 120/85 √EXT SS DFN3x3-10SY8223 4.5 23 3 0.5 0.6 ±1.5% 400 120/85 √EXT SS, Hic-cup SCP DFN3x3-10SY8253 4.523 3 0.5 0.6 ±1.5%100105/50 √EXT SS, Hic-cup SCP TSOT 23-8SY8303 4.5 40 3 0.5~2.5MHz 0.6 ±1.5% 18 70/110 TSOT 23-8SY82935 40 3 0.8 0.6 ±2.0%160180/- SO8ESY8113H 4.5 18 3 0.5 0.6 ±1.5% 160 80/40 Programmable soft-start time TSOT 23-8±1.5%SY8104A4.518 4 0.5 0.6±1.5%100 50/30Instant PWM architectureSY8105 4.5 18 5 0.5 0.6±1.5%100 50/30SY8205 4.5 30 5 0.5 0.6±1.5%200 70/40√EXT SSSY8105A 4.5 18 5 0.5 0.6±1.5%100 40/20Instant PWM architectureSY8366H 4 28 6 0.8 0.6±1.5%100 40/20√Hic-cup SCP, 12A Peak current capability,programmable output current limitSY8286A 4 23 60.6 0.6 ±1.0% 12038/19 √SY8366K428 6 0.50.6±1.5%10040/20√Hic-cup SCP,6A continuous/12A peakoutput current capabilitySY8368A42880.80.6±1%100 20/10√Hic-cup SCP, 16A Peak current capability,programmable output current limitSY8288A 4 23 8 0.5 0.6 ±1.0% 80 30/10SY8288 4 23 8 0.5 0.6 ±1.0%8030/10SY8288C5.52380.60.6±1.5%10822/11√OVP/OCPSY8210A 4 28 10 0.6 0.6±1.5%300 25/8√Mem o ry power, 10A VDDQ/1A VTT LDO, 16A Peak Current capability, Latch offUVP/OVP, Over temperature alertSY8204 4.5 30 40.50.620080/50EXT SSPackageTSOT 23-6SO8ETSOT 23-6TSOT 23-6DFN3x4-12TSOT 23-6QFN3x3-12QFN3x3-20QFN3x3-12QFN3x3-12QFN3x3-20 QFN3x3-20QFN3x3-20QFN4x3-19Part Number Vin(min)(V)Vin(max)(V)Iout(max)(A)Fsw (MHz) Vout(min)(V) Voltage AcurracyQuiescent Current (uA)MO SFET(Ron H/L) (m ? ) Power Good OutputFeature/ Special Function Package SY8182 4 18 12 0.2~1MHz 0.6 ±1.0%18/6 √QFN4x4-20SY8182L 4.5 18 12 0.2~1MHz0.6 ±1.0% 500 18/6 √ Hic-cup SCP/OVPQFN4x4-24 SY8186418160.50.6±1.5%1507.5/2.5√Hic-cup SCP, programmble outputQFN4x4-11current limitPart NumberVin(min)(V)Vin(max)(V)Ilim (A)Fsw (MHz)Vout(max)(V)Sync BoostFixed O utputVoltage (V) Acu F r B ra /c y AcurracyInput Q uiescent Current (uA)Q uiescent current from output (uA)MO SFET Ro n (L/S) (m ? )Feature/ Special Function PackageSY7060L 0.7 5 0.2 / 5.25 Y /0.5V ±3% 0.518450/800SOT-363SY7070 0.7 5 0.35 / / Y 3.3 /0.5 5.5 500/700Bypass function @ shutdown SOT 23-5SY7070A 0.7 5 0.35 / / Y 3 / 0.5 5.5 500/700SOT 23-5SY7071 0.7 5 0.35 / 5.25 Y /1.0V ±3%0.5 5 500/700 Pass-through function @ shutdown SOT-363SY7071A 0.7 5 0.35 / / Y 5 / 0.5 7 400/500Pass-through function @ shutdown SOT-363SY7060 0.7 5 0.4 / 5.25 Y /0.5V ±3% 0.5 18 450/800SOT-363SY7080 0.9 4 1.8 1.2 4 Y / 1.2V ±3%65 / 90/200 Output Disconnect @Shutdown SOT 23-6Single output step Up (Boost) Converter (Low V oltage)Part NumberVin(min)(V)Vin(max)(V)Ilim (A)Fsw (MHz)Vout(max)(V)Sync BoostFixed O utput Voltage (V)Acu F rr B a /c y Acurracy InputQuiescent Current (uA) Quies cent current from output (uA) MOSFET Ron(L/S) (m ?) Feature/ Special Function PackageSY7063 1.8 5.25 3 0.5 5.5 Y / 1.2V ±1.5% 102736/40Output Disconnect @Shutdown QFN2x2-10SY7069 2.5 5.5 3 1 5.5 Y / 1.2V±1.5% 8 32 50/90TSOT 23-6SY7088 2.3 5 3 1 5.5 Y / 1.2V ±1.5% 2 30 70/85DFN2x3-8SY7088E 2.3 5 3 1 5.5 Y / 1.2V ±1.5% / / 70/85DFN2x3-8SY7065 1.8 5.25 5 0.5 5.5 Y / 1.2V ±1.5% 10 27 20/40 Auto output discharge function QFN2x2-10SY7065A 1.8 5.25 5 0.5 5.5 Y / 1.2V ±1.5% 10 27 20/40No output discharge function QFN2x2-10SY7076 2 5.5 6 0.5 5.5 Y / 1.2V ±1.5% 10 27 20/40QFN2x2-10SY7066 1.8 5.25 6 0.5 5.5 Y / 1.2V ±1.5% 10 27 20/40 Auto output discharge function QFN2x2-10SY7066B 1.8 5.25 6 0.5 5.5 Y / 1.2V ±1.5%10 27 20/40 Selectable Forced PWM mode QFN2x2-10Single output step Up (Boost) Converter (Low V oltage)SY9701A 2.6 5.5 1.2 1 5.5 0.6V ±1.5% 60 100/100 Output Disconnect @Shutdown DFN3x3-14Single output step Up (Boost) Converter (High Voltage)PackagePart NumberVin(min)(V)Vin(max)(V)Ilim (A)Fsw (MHz) Vout (max) (V) Sync BoostFB/ AcurracyInput Q uiescent Current (uA) MO SFET (RonMain/Rectified)(m? )Disconnect FET Ron ( m ?) Power Good OutputFeature/ Special FunctionSY7208C 3 25 0.6 1 25 N0.6V ±2%100 150/-Int SS/CompSOT 23-6SY7152A 3 8 2 1 16 N0.6V ±2%100 130/-Int SS/Comp SOT 23-6SY7208L 3 25 2 1 25 N0.6V ±2%100 150/-Int SS/Comp SOT 23-6SY7302 3 33 2 1 33 N0.6V ±2% 100 200/-Int SS/Comp SOT 23-6SY7388 3.5 30 2 0.85 30 N 1V ±2%150 200/-Accurate input current limit SOT 23-6SY7102 2 6 2.5 1 6 N0.6V ±2% 200 120/-Int SS/Comp SOT 23-6SY7801 2.5 5.5 2.5 1 / N 0.6V ±2%200 120/-Int SS, with 2A 80m? Load Switch DFN3x3-12SY7104A2 6 4 1 6 N0.6V ±2% 100 90/-Int SS/Comp DFN3x3-10SY7304 3334133N 0.6V ±2%100120/-QFN3x3-10SY7205 8.6 15.9 4.5 0.5 16 N1.25V±1.5% 120 75/-Adjustable soft-start time, OVP DFN3x3-10SY7982 3 9 6 1 13 Y 1V ±2% 600 80/4040√True shutdown QFN3x3-16SY7219 3 5.5 9 / 36 N 1.25V ±2%350 65/-EXT Comp DFN3x3-10 SY721531615/18Y1V ±1.5% 22016/1818√Int SS, OVP/SCP/ True shutdown ProgrammableSwitching Frequency: 0.2~1MHz QFN4x4-18SY7215A31615/18Y 1V ±1.5%2309/1212√Int SS, OVP/SCP/ True shutdown ProgrammableSwitching Frequency: 0.2~1MHzQFN4x4-181.23VInt SS; Adjustable current limit for optical module;SY7501B2.955.50.930.480N ±2%225 800/-Current limit indicator; Accurate high-side currentQFN3x3-16monitor; 320mW maximum output powerDC-DC PWM Controller (external Switch)Original Part Number Vin(min)(V)Vin(max)(V)Fsw (MHz)V(V R)EFFunction PackageSY7901 3 25 0.5 1 Current mode DC/DC controller targeted for Boost, Sepic, Flyback and Forward applications with DC Input Current Limit DFN3x3-10 SY7902A 3 25 0.3 1 Current mode DC/DC controller targeted for both Boost and Sepic applications with DC Output Current Limit SOP10 Power ModulePart Number Vin(min)(V)Vin(max)(V)Iout(max)(A)Fsw (MHz)Fixed O utputVoltage (V)Voltage Acurracy Q uiescent Current (uA) MOSFET (Ron H/L) (m? ) Integrated Inductor PackageSY98081 2.5 5.5 0.6 3 ±2% 40 230/150 √QFN2x1.5-8 SY98001 2.5 5.5 1.2 3 ±2% 40 230/150 √QFN2.5x2-8 SY98003 2.7 5.5 3 3 ±1.5% 60 35/15 √QFN3x3-10 SY98004 2.7 5.5 4 3 ±1.5% 60 35/15 √QFN3x3-10 SY98002 2.7 5.5 2 3 ±1.5% 60 20/40 √QFN3x3-10 SY98202 4.5 23 2 2 ±1.5% 100 50/105 √QFN3x3-10 SY98195 4.5 18 5 1.5 ±1.5% 15/50 √QFN5x5-20LDO RegulatorPart Number Vin(min)(V)Vin(max)(V)Vout(V)Iout(A)Dropout Voltage (mV) Function PackageSY6340 2.3 30 Output Voltage Adjustable 0.15 300 LDO Reg SOT23-5D FN2×2-6 SY6340B 3.6 30 3.3 0.05 100 LDO Reg SOT 23-5SY6345 4 40 Adjustable 0.3 300 LDO Reg SOT 23-5SY6301 1.6 5.5 Output Voltage Adjustable 1 0.32V at I OUT =1A, V OUT =1.5V0.18V at I OUT =1A, V OUT =2.8VLDO Reg DFN3×3-6SY6307B 0.8 5.5 Output Voltage Adjustable 0.5 90 LDO Reg DFN1.2x1.2-6 Protection SwitchPart Number Package Enabl eLogic O CP O VP No. ofChannelsVin(V) Vout(V) Iout(A) Rds(on) TUV/CBCertificateULCertificateSpecial FunctionSY6280A SOT 23-5 H Y N 1 2.4~5.5 2.4~5.5 0.4~2 63m? Programmable current limit, reverse blockingSY6281A SOT 23-5 L Y N 1 2.4~5.5 2.4~5.5 0.4~2 63m? Programmable current limit, reverse blockingSY6288A SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 0.6 80m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288B SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 0.6 80m? ? ? Output discharge at shutdown Reverse Blocking,OCB indicatorSY6811 CSP0.9x0.9-4 H N N 1 1.05~1.95 1.05~1.95 1 45m?@VIN=1.2V35m?@VIN=1.8V Auto output cap discharge function, utra low inputvoltageSY6819A SO8 H Y N 1 4.5~18 4.5~18 1.2 110m?@VIN=12V Programmable blanking t ime for DFF control, Default Off when EN ONSY6819 SO8 H Y Y 1 4.5~18 4.5~18 1.2 110m?@VIN=12V Programmable blanking t ime for DFF control,Default On when EN ONSY6288C20 SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 2 65m? ? ? Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288D20 SOT 23-5 L Y N1 2.5~5.5 2.5~5.5265m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorPart Number Package EnableLogicOCP OVPNo. ofChannelsVin(V) Vout(V) Iout(A) Rds(on)TUV/CBCertificateULCertificateSpecial FunctionSY6882A DFN2x2-8 H N Y 1 3~23 3~23 2 100m?Internal Fixed Over-Voltage Protection Threshold @7.1V, Thermal Shutdown Protection&Auto RecoverySY6882B DFN2x2-8 H N Y 1 3~23 3~23 2 100m? Programmable OVP Threshold Thermal Shutdown Protection& Auto RecoverySY6883 SOT 23-6 L N Y 1 3~23 3~23 2 100m? Programmable OVP Threshold Thermal Shutdown Protection& Auto RecoverSY6822 QFN2x2-10 L Y N 1 3~6.6 3~6 2 60m? Bidirectional Current Limit SwitchSY6288C7 SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288D7 SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288C5 MSOP8 H Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288D5 MSOP8 L Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288E1 SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 3 45m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288E2 SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 3 45m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288F1 SOT 23-6 H Y N 1 2.5~5.5 2.5~5.5 3 45m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288F2 SOT 23-6 L Y N 1 2.5~5.5 2.5~5.5 3 45m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6283A DFN1.2×1.6-4 H Y N 1 2.5~5.5 2.5~5.5 3 60m? Output discharge at shutdown Reverse Blocking SY6283 DFN1.2×1.6-4 H Y N 1 2.5~5.5 2.5~5.5 3 60m? Reverse blocking output, ultra low input voltage SY6813 6 ball CSP H N N 1 1.2~5.5 1.2~5.5 3 22m? Auto output cap discharge functionPart Number Package EnableLogicOCP OVPNo. ofChannelsVin(V) Vout(V) Iout(A) Rds(on)TUV/CBCertificateULCertificateSpecial FunctionSY6288D20 SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 2 65m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6882A DFN2x2-8 H N Y 1 3~23 3~23 2 100m?Internal Fixed Over-Voltage Protection Threshold @7.1V, Thermal Shutdown Protection&Auto RecoverySY6882B DFN2x2-8 H N Y 1 3~23 3~23 2 100m? Programmable OVP Threshold Thermal Shutdown Protection& Auto RecoverySY6883 SOT 23-6 L N Y 1 3~23 3~23 2 100m? Programmable OVP Threshold Thermal Shutdown Protection& Auto RecoverSY6822 QFN2x2-10 L Y N 1 3~6.6 3~6 2 60m? Bidirectional Current Limit SwitchSY6288C7 SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288D7 SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288C5 MSOP8 H Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288D5 MSOP8 L Y N 1 2.5~5.5 2.5~5.5 2.5 70m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288E1 SOT 23-5 H Y N 1 2.5~5.5 2.5~5.5 3 45m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6288E2 SOT 23-5 L Y N 1 2.5~5.5 2.5~5.5 3 45m? √√Output discharge at shutdown Reverse Blocking,OCB indicatorSY6283A DFN1.2× 1.6-4 H Y N 1 2.5~5.5 2.5~5.5 3 60m? Output discharge at shutdown Reverse Blocking SY6283 DFN1.2× 1.6-4 H Y N 1 2.5~5.5 2.5~5.5 3 60m? Reverse blocking output, ultra low input voltage SY6813 6 ball CSP H N N 1 1.2~5.5 1.2~5.5 3 22m? Auto output cap discharge functionPart Number Package EnableLogicOCP OVPNo. ofChannelsVin(V) Vout(V) Iout(A) Rds(on)TUV/CBCertificateULCertificateSpecial FunctionSY6823 DFN2x2-8 H N N 2 0.6~5.5 0.6~5.5 4 28m? Programmable turn-on delay& ramp-up time,integrated OTP SCPSY6818 CSP1.73x1.73-12 H N Y 1 2.5~30 2.5~20 5 R PWPT =53m? (typ) Programmable OVP with Integrated Reverse Blocking FET, acurrate current level indicatorSY6874 DFN3x3-10 H Y Y 1 2.5~30 2.5~14 4 50m? Programmable softstart¤t limit,3.3V/5V/12V selectable clamping outputSY6875A DFN3x3-10 H Y Y 1 2.5~30 2.5~14 5 40m? Programmable softstart¤t limit,3.3V/5V/12V selectable clamping outputSY6875C DFN3x3-10 H Y Y 1 2.5~30 2.5-14 5 40m? Programmable softstart¤t limit, 3.3V/5V/12V selectable clamping outputSY6875D DFN3x3-10 H Y Y 1 2.5~30 2.5-14 5 40m? Programmable softstart¤t limit, 3.3V/5V/9V selectable clamping outputSY6875F DFN3x3-10 H Y Y 1 2.5~30 2.5-14 5 50m? Programmable softstart¤t limit,3.3V/5V/12V selectable clamping outputSY6895A DFN3x3-10 H Y Y 1 2.5~12 2.5~6.5 5 40m? Fixed Current Limit, Prog.SS SY6895C DFN3x3-10 H Y Y 1 2.5~12 2.5~6.5 5 40m? Fixed Current Limit, Prog.SSSY6880C CSP1.8x2-12 H N Y 1 2.5~28 0~7 5A continous,8A peak38m?Fixed intenal OVP@6.8V, Reverse block, Surgeprotection up to 80VSY6880A CSP1.8x2-12 H N Y 1 2.5~28 0~7 5A continous,8A peak 38m?SY6829 CSP0.79x0.79-4 H N Y 1 2.5~6 0~7 1 96m? Precise clamping output voltageSwitching ChargerPart Number Function Vin (V)Max. ChargeCurrent (A)Fsw (MHz) Series Cells Cell Voltage Special Function PackageSY6903A Single-Cell Bi-directional Power Bank 4.5-5.5 2 0.5 Single Cell 4.2V adaptive current limit, 2.4A Boost QFN3x3-16 SY6923 Single-Cell with USB-OT G 4~6 1.55 3 Single Cell 3/5~4.44V Compliance with USB and USB OT G, MTK reference design CSP 1.93x2.05-20 SY6923D Single-Cell with USB-OT G 4~6 1.55 3 Single Cell 3.5~4.44V Compliance with USB and USB OTG CSP 1.93x2.05-20 SY6923D1 Single-Cell with USB-OT G 3.5- 4.44 1.25/1.55 3 Single Cell 4.2V Compliance with USB and USB OTG CSP 1.93x2.05-20SY6932 Multi-cell Charger Step Down Reg. 4~23 2 0.8 1-3 Cells 4.2VProg. Charge Current&Timer,Output Power PathManagementQFN4x4-16SY6952A Single-cell Charger Step Down Reg. 4~23 2 0.8 Single Cell 4.2V,4.35V Power Path Management and Adaptive Input Current Limit QFN4x4-16 SY6952C Single-cell Charger Step Down Reg. 4~23 2 0.8 Single Cell 4.2V, 4.35V Power Path Management and Adaptive Input Current Limit DFN3x3-12 SY6952B1 Single-cell Charger Step Down Reg. 4~23 2 0.8 Single Cell 4.1V, 4.4V Adaptive Input Current Limit SO8ESY6982C 2 cell Boost Li-Ion Baterry Charger 3.6~5.5 2 1 2 Cells 4.2V, 4.35V Prog. Charge Current&T imer,Adaptive Input Current Limit QFN3x3-16SY6982C1 2 cell Boost Li-Ion Baterry Charger 3.6~5.52 12 Cells 4.1V, 4.25V Prog. Charge Current&T imer,Adaptive Input Current Limit QFN3x3-16 SY6982D 2 cell Boost Li-Ion Baterry Charger 3.6~5.5 2 1 2 Cells 4.1V, 4.2V, 4.3V, 4.35V Prog. Charge Current&T imer,Adaptive Input Current Limit QFN3x3-16SY6982E2 cell Boost Li-Ion Baterry Charger 3.6~5.52 12 Cells 4.2V, 4.35VProg. Charge Current&T imer,Adaptive Input Current LimitQFN3x3-16SY6982E12 cell Boost Li-Ion Baterry Charger 3.6~5.52 12 Cells 4.25V, 4.4VProg. Charge Current&T imer,Adapter and BAT IN IndicatorQFN3x3-16SY6982F 2 cell Boost Li-Ion Baterry Charger 3~5.5 2 1 2 Cells 4.2V Prog. Charge Current&T imer,Adapter and BAT IN Indicator QFN3x3-16 SY6903 Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.2V 3in1, Adaptive current limit, 2.4A Boost QFN3x3-16 SY6903B Single-Cell Bi-directional Power Bank 4.5~5.3520.5 Single Cell 4.35V 3in1, Adaptive current limit, 2.4A Boost QFN3x3-16Part Number Function Vin (V)Max. ChargeCurrent (A)Fsw (MHz) Series Cells Cell Voltage Special Function PackageSY6908 Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.2V 3in1, Adaptive current limit, 2.5A Boost QFN3x3-16SY6908A Single-Cell Bi-directional Power Bank 4.5~5.5 2 0.5 Single Cell 4.2V 3in1, Adaptive current limit, 2.5A Boost QFN3x3-16 SY6908B Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.35V 3in1, Adaptive current limit, 2.5A Boost QFN3x3-16 SY6908D Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.2V 3in1, Adaptive current limit, >10000mAH BAT, 2.5A Boost QFN3x3-16 SY6908E Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.35V 3in1, Adaptive current limit, >10000mAH BAT, 2.5A Boost QFN3x3-16 SY6918 Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.2V,4.35V Prog. current limit, 18V input voltage surge QFN3x3-16 SY6918A Single-Cell Bi-directional Power Bank 4.5~5.35 2 0.5 Single Cell 4.2V,4.35V Prog. current limit, 18V input voltage surge QFN3x3-16SY6918B Single-Cell Bi-directional Power Bank 4.5-5.3520.5 Single Cell 4.2V, 4.35V Prog. current limit, 18V input voltage surge QFN3x3-16SY6990 Single-Cell Bi-directional Power Bank 4~13.5 5 0.5 Single Cell 4.1V,4.2V,4.25V,4.4VI2C controlled, USB Complianced, 5V/3A&12V/1.2A Boost QFN4x4-24SY6992 Single-Cell Bi-directional Power Bank 4~13.5 5 0.5, 0.3 Single Cell 4.1V,4.2V,4.25V,4.4V I2C controlled, USB Complianced, 5V/4A&12V/1.5A Boost QFN4x4-20SY6993 Single-Cell Bi-directional Power Bank 4~13.5 5 0.5, 0.3 Single Cell 4.1V,4.2V,4.25V,4.4VI2C controlled, USB Complianced, 5V/4A&12V/1.5A Boost QFN4x4-20 SY6935 High Current Step-down Charger 4~14 3.5 1 1-2 Cells 4.2V, 4.35V Adaptive input current limit, Blocking FET integrated QFN3x3-16 SY7994 Synchronous Boost converter with QC3.0 3~4.5 NA 0.3, 0.5 Single Cell NA QC3.0 Compliance QFN4x4-20Power Management I CsPart Number Vin(min)(V)Vin(max)(V)Num ber ofChannelsPackage Application Integrated FunctionSY8675 9.3 18 3 SO8E TV power system 1 synchronous buck, 1 sy cnh ronous buck, 1 load switchSY8670 8 25 6 QFN5X5-32 TV Power System 4-Channel Step-Down onCve rter, 2-Channel LDOSY8632A 4.5 18 3 QFN5x5-32 TCON Power System I2C controlled 3-channel Buck RegulatorsSY6401A 4 18 1 DFN3x3-10 SSD Programmable charging current Automatic bi-directional energy flowSY6402 2.7 16 1 QFN3x4-19 SSD Input-side current limit switch Bi-directional DC-DC Regulator wit disconnhe ct switch: Boost Charging Mode and Buck Discharging Mode SY8645 3.4 5.5 8 QFN5x5-32 POS 4 Buck Converter, 2 LDO, one MOS switch, one load switch&one voltage detector.SY7630 2.5 5.5 3 QFN4x4-24 Monitor/NB LCD Panel Power AVDD Boost, VGH/VGL charge pump, VCOM OPAMP, GPMSY7630B 2.3 5.5 3 QFN4x4-24 Monitor/NB LCD Panel Power AVDD Boost, VGH/VGL charge pump, VCOM OPAMP, GPMSY8671 9.1 14.7 6 QFN6X6-40 TV LCD Panel Power 1 AVDD Boost, 1 HAVDD Buck, 2 Buck, 1 VON Boost, 1 VOFF Buck-BoostSY8673 8 18 5 QFN7x7-48 TV LCD Panel Power AVDD Boost, VGH/VGL charge pump, VCOM OPAMP, GPM, DVDD, Gammar reference LDOSY7615 8 18 2 DFN3x3-10 wer supply and control for satellite set t Boost, LNB BlogSY7615A8 18 2 DFN3x3-10 LNB power supply and control for s at elliteset top boxesBoost, LNB BlogSY8631 2.5 5.5 6 QFN4x4-24 Camera module Step Down Buck Regulators,3 Low Dropout LDO and 1 Channel RESET OutputSY86304 20 3DFN3x3-12 Security CCD Camera power supply 2 Buck converters and 1 Boost converterSY86412 5 5QFN3x3-16 3D Glass 1 Boost output with analog switches for 3D glassesSY8660C 2.7 5.5 1 DFN3x3-14 U SB Powered Devices Buck converter with programmable current limit switchSY8689 4.5 18 3 QFN4x4-24 TV Power/USB Ports and Hubs/Set-Top Dual synchronous buck regulator and an N-channel back-to-back power MOSFET switch。
Belimo 01APS-1 压力差检测器说明书
01APS-1..Differential pressure switchFor monitoring overpressure, vacuum and differential pressure of air or other non-combustible, non-aggressive gases. Typical application in HVAC systems for filter or fan V-belt monitoring. With setpoint adjustment and automatic reset function.Type OverviewType Measuring range diff. pressure Repeating accuracy Switching differential [pressure]01APS-10U 50...500 Pa ±2.5%, min. ±5Pa 20 Pa 01APS-101200...1000 Pa ±1%, min. ±5 Pa 100 Pa 01APS-104500...2500 Pa ±1%, min. ±5 Pa 150 Pa 01APS-10R20...300 Pa±5%, min. ±5 Pa10 PaTechnical DataElectrical dataElectrical connection Terminals for wire 0.5...1.5 mm²Cable entryCable gland cap nut with strain relief Ø5...10 mmFunctional data Output signal switch note Contact current max. 1.0 A (0.4) / AC 250 V MediaAirMeasuring dataMeasuring values Differential pressureMeasuring mediaAir, non-combustible and non-aggressive gasesMaterials Housing Bottom Part: PA 6.6Top Cover: PS Safety dataBurst pressure 10 kPaAmbient humidity Max. 95% r.H., non-condensing Ambient temperature -20...85°C [-5...185°F]Medium temperature -20...85°C [-5...185°F]Storage temperature -40...85°C [-40...185°F]EU Conformity CE-Kennzeichnung Certification IEC/EN IEC/EN 60730-1Degree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 3Quality StandardISO 9001The installation and assembly of electrical equipment should only be performed by authorized personnel.This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets.Ensure all power is disconnected before installing. Do not connect to live/operating equipment.Please comply with• Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manualRemarksThe specifications for the switching pressure refer to a vertical installation position, which is also recommended with downward pressure connections. For horizontal mounting position with upwards directed AMP connecting lugs, the switching values are approx. 20 Pa higher. It is not permitted to mount the pressure switch upside down!Scope of deliveryPVC tube 2 m2 x Duct connectors (plastic)AccessoriesOptional accessoriesDescriptionType(328447) Description text sensor accessory1A-22AP-A06(328447) Description text sensor accessory1A-22AP-A07(328447) Description text sensor accessory1A-22AP-A11.1(328448) Description text sensor accessory2A-22AP-A05.1Wiring diagramRecommended installation positionsDimensionsType Weight 01APS-10U 0.15 kg 01APS-1010.15 kg 01APS-1040.15 kg 01APS-10R0.15 kg。
Agilent SPME Fiber or Arrow Manual Injection Kit U
12345SPME Fiber or Arrow Manual Injection KitSPME manual samplingThe Agilent manual injection kit will allow the end user to extract samples using SPME fibers or Arrows. They can then inject the samples into a GC inlet.Manual SPME SamplingSPME fibers and Arrowsp/n 5191-58772PAL3 alignment ring (gray) for split/splitless (S/SL) inletManual injectionManual injection guidePAL3 alignment ring (Gray) for S/SL inlet (G7371-67001)The manual injection guide sits on thealignment ring for manual sample injection.3Methodology—manual samplingInstalling a PDMS SPME (100 μm) Arrow into the manual syringeLoosen the cap at the base of the syringe and remove it.Depress the black plunger completely.Screw the hub of an SPME fiber/Arrow into the bottom of the plunger at the end of thesyringe bodyRetract the black plunger and slide the cap over the SPME fiber/Arrow and tighten itonto the syringe.4The extraction guide has two positions where the syringe can be installed.The upper position is used for headspace extraction.The lower position is used for immersion extraction.Incorrect and correct position of the lower locking screw.Do not tighten the screw against the black plunger or you will not be able to move the SPME fiber/Arrow intoposition for sampling.Setting the locking screwsLarge inner diameter (id) locking screwSmall inner diameter (id) locking screwSlide the locking screws onto the syringe from the plunger side (the right side as shown above).• Install the large id locking screw onto the silver body of the syringe.• Install the small id locking screw onto the wider portion of the black plunger.•Tighten the locking screws until finger-tight. Do not overtighten, as they will be adjusted in later steps.5• Raise the syringe plunger to the fully extended position and insert the syringe and lower locking screw into the upper position of the extraction guide.•Lock the syringe into place by rotating it until the locking screw is positioned in the notch.• Adjust the syringe so that the SPME fiber/Arrow is protruding ~1 cm beyond the inner base of the extraction guide (A).• Tighten the lower locking screw securely.•The tip of the SPME fiber/Arrow will be recessed at least 1 mm in from the end ofthe extraction guide (B).A BSetting the locking screws for septum penetration depthPlace the extraction guide (with syringe in place) on a headspace sampling vial and loosen the upper locking screw.Adjust the SPME fiber/Arrow to the desired exposure depth by moving the black plunger.Choose a depth that ensures that the SPME fiber/Arrow will be in the gas phase.Once the SPME fiber/Arrow is at the proper depth, hold the plunger in place and slide the upper locking screw until it is flush against the top of the silver syringe body. Then tighten the upper locking screw securely.Setting the exposure depth for headspace extraction6Fine depth adjustment for direct immersion extractionAdjusting the injector penetration depthInsert the syringe into the lower position of the extraction guide.1. Manual SPME injection guide2. PAL3 alignment ring (gray) forS/SL inlet (G7371-67001)• Carefully insert the syringe into the injection guide.• Use caution to avoid damaging the SPME fiber/Arrow when threading it through the hole in the base of the injection guide.•Lock the syringe into place by rotating it until the locking screw is positioned in the notch.Penetrate a vial and fully expose the SPME fiber/Arrow within the vial.Adjust the lower locking screw and upper locking screw to obtain the desired exposure depth (to ensureimmersion in the sample liquid).127Setting injector penetration depthWith the appropriate GC-specific adaptor cup on the end of the injection guide, measure the distance from the tip of the SPME fiber/Arrow to the groove inside the adaptor cup.Adjust the desorption depth by screwing the body of the injection guide up or down (maximum depth = 67 mm).Twist the locking ring down until it locks on the body of the injection guide./chemDE.3985648148This information is subject to change without notice.© Agilent Technologies, Inc. 2020 Printed in the USA, March 6, 2020 5994-1732ENInjection onto the GC inletRemove the adapter cup from the injection guide.The adapter cup is placed onto the GC inlet to guide the manual injection.Push the plunger down until the top locking screw is resting on the body of the syringe.The sample is then injected.。
SYSTEMSENSOR SS-310-00 1 I56-3381-002 INSTALLATION
SpecificaTiOnS Dimensions: 4.8"W x 5.3"H x 1.6"D (12.2cm W x 11.9 cm H x 3.8 cm D)Weight:0.35 lb. (160 g)Operating Voltage: 20-29 VDCPower Requirements Standby: 3.0 mA max. Trouble:16.0 mA max Alarm w/o strobe: 30 mA max Alarm with strobe: 55 mA maxConnections: Strip terminal, 14 A WG to 22 A WG wire Wiring Distance: 1000 Feet From Duct Smoke Detector Sounder: 85 dBA at ten feetT emperature: 14°F to 140°F (-10°C to 60°C)Humidity: 95% relative humidity; non-condensing Listing:UL 268rTS2, rTS2-aOS, aOS multi-Signaling accessoryinSTaLLaTiOn and mainTenance inSTrucTiOnS3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6495H0621-00I56-3381-002Notice: This manual should be left with the owner/user of this equipment.generaL infOrmaTiOnThe National Fire Protection Association (NFPA) has published codes, stan-dards, and recommended practices for the installation and use of this product. It is recommended that the installer be familiar with theses requirements, with local codes, and any special requirements of the local authority having juris-diction. For further information, consult NFPA 72 and 90A requirements.The System Sensor RTS2 and RTS2-AOS multi-signaling accessories are de-signed for use with System Sensor InnovairFlex 4-wire conventional duct smoke detectors only. The accessory has two bicolored LEDs that indicate the sensor status of up to two connected duct smoke detectors. The key switch on the unit can be used to select a connected duct detector sensor (either sen-sor 1 or sensor 2), and the selected sensor can be tested or both sensors can be reset simultaneously using the test/reset button. LED status indications include: Standby (green blink), Trouble (amber), Maintenance (amber blink) and Alarm (red).With the key switch selected, there is also the capability of obtaining a sen-sitivity measurement of the selected sensor using the SENS-RDR sensitivity reader (sold separately).Specific feaTureS Of The rTS2 and rTS2-aOS incLude:Standby (Green Blink), Trouble (Amber), Maintenance (Amber Blink) • and Alarm (Red) LEDs to indicate detector status Keyswitch to select desired sensor, enable test/reset button and • sensitivity reading T est/reset button• Sensitivity reading ability with SENS-RDR (sold separately)• Selectable continuous or temporal tone• AOS-Add-On-Strobe (included on RTS2-AOS model)• Provisions for single- or double-gang box mounting• Ability to discretely monitor two sensors when duct smoke detectors • are configured in a 2-to-1 set up (See InnovairFlex duct smoke detector manual for reference.)cOnTenTS1 RTS2 or RTS2-AOS Multi-Signaling Accessory1 Mounting Hardware Kit (Contains (2) sets of mounting screws and (1) tam-per resistant outer cover mounting screw.figure 1:figure 3: Wiring diagraminSTaLLaTiOninstalling the mounting plate1. S ecure the mounting plate to a single- or double-gang electrical box with(2) mounting screws provided. Note: If mounting to a single-gang box, the Add-On Strobe (AOS) must be removed prior to mounting. T o remove the AOS, squeeze opposing sides lightly next to arrows and slide vertically. 2. I f applicable, install the AOS onto the mounting plate as shown in Figure 2. Note, the RTS-AOS includes the AOS.Temporal SounderThe RTS2 accessory provides the option of sounding a continuous or temporal pattern. The RTS2 will default to sound in a temporal pattern. For a continu-ous pattern, remove the jumper located just to the right of the “Strobe” text on the mounting plate as shown in Figure 2.WiringWire the RTS2 as shown in Figure 3, for InnovairFlex 4-wire conventional duct smoke detectors. Limit wire runs to 25 ohms or less per interconnecting wire. nOTe:1. I f polarity of Acc. (+) and Acc. ( —) are reversed, an Amber LED on sensor2 of the duct smoke detector power board will exist indicating a trouble condition.2. One RTS2 can be wired to only one InnovairFlex power board.3. I f Aux. (+) and Aux. (—) wires are reversed, the strobe and sounder will not function.installing the Outer cover1.Install the outer cover on the mounting plate by sliding the outer cover over the upper tabs of the mounting plate as shown in Figures 4 and 5.2.Tighten the outer cover mounting screw located at the bottom of the device. Note: The mounting screw can be replaced with the provided tamper resistant Torx screw, if desired.LEDsROUTER COVER L OCKING SCRE W Y READERH0624-00figure 2:OperaTiOnThe green “Standby” will blink every 5 seconds whenever the duct smoke detector is receiving power. The amber “Trouble” LED is lit when the duct smoke detector sensor is missing or the detector cover is removed. The delay to indicate a trouble condition once the cover is removed depends on the dip switch setting on the duct smoke detector power board. An LED with amber blink every 5 seconds indicates that the sensor is in “Maintenance” which in-dicates that the sensor needs to be cleaned or replaced. See T able 1 LED Status Indication for a detailed list of indications.enabling the Test/reset/Sensitivity OperationInsert the key and turn to select either sensor 1 or 2. This will enable the selected sensor to be tested, reset, or sensitivity read. Note all test/reset/sen-sitivity functions can be initiated with the outer cover installed or directly on the mounting plate.Test functionWith the desired sensor selected by the key, press and hold the T est/Reset but-ton for 2 seconds. If the sensor is within its sensitivity limits, the device will alarm within the next 3 seconds.alarm indicationOnce the T est/Reset button has been pressed, the red alarm LED will illumi-nate and the horn will sound (within 5 seconds). If an AOS (add-on strobe) is installed, it will flash.reset functionReset is a common function to both sensors. Press and release the T est/Reset Button. The red alarm LED should turn off on both sensor LEDs and the horn will cease sounding. The strobe will cease flashing (if optioned). The current sensor status will be indicated (See T able 1). Note, the key switch must still be selected for one of the sensors in order for the reset function to be enabled.Sensitivity functionWhen the key is installed and sensor 1 or 2 is selected, the selected sensor sensitivity can be read via a SENS-RDR (sold separately).1. Select the desired sensor with the key.2. P ress the test button on the SENS-RDR. “Ready” should appear on the SENS-RDR display.3. H old the SENS-RDR up to the oval indentation on the mounting plate or outer cover (if installed). Within 10 seconds the sensor sensitivity will be displayed.disabling the Test/reset/Sensitivity OperationWhen the key switch is returned to the neutral (vertical) position and removed, the Test/Reset button will be disabled.H0623-00H0625-00figure 4:figure 5:mode indication Off LEDs off Initialization Green/Amber blinkNormal Green blink Maintenance Amber blink Communication ErrorAmber long blink Trouble Solid Amber AlarmSolid RedTabLe 1: Led STaTuS indicaTiOnS* P lease note that the mode of the LEDs on the RTS2 represent the mode of the respective sensors connected to the InnovairFlex duct power board.** R efer to the InnovairFlex installation and maitenance instructions for additional LED/Status details.System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to in-crease or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the replacement of any part of the product which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns Department, RAThree-Year LimiTed WarranTY#__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.The sounder or sounder/strobe combination will not operate if the power is cut off for any reason.If power is cut off for any reason, the sounder or strobe/sounder combination will not provide the desired audible or visual warning.The sounder may not be heard. The loudness of the sounder meets or exceeds the current Underwriters Laboratories’ standards. However, the sounder may not alert a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This sounder may not be heard if it is placed in an area that is separated by a closed door, or if it is located on a different floor from the person in a hazardous situation, or if it is placed too far to be heard over ambient noise, such as, traffic, air conditioners, machinery or musical appliances that may prevent alert persons from hearing the alarm. For these reasons, System Sensor recommends that sounders (85dBA minimum at 10 feet) used in a residence shall be placed on every level and in every bedroom that does not have a smoke detector with a built-in sounder.)The sounder may not be heard by persons who are hearing-impaired. In this case, a visual indicator shall also be used.The Sounder and add-on strobe are for supplemental signaling only. The signal strobe may not be seen. The visual warning signal is suitable for direct viewing and must be installed within an area where it can be seen by building occupants. The strobe must not be installed in direct sunlight or ar-eas of high light intensity where the visual flash might be disregarded or not seen.The strobe may not be seen by the visually impaired.The signal strobe may cause seizures. Individuals who have a positive photic response to visual stimuli with seizure, such as epileptics, should avoid pro-longed exposure to environments in which strobe signals, including this strobe, are activated.SENSOR UNITPOWER BOARD UNITH0621-00H0627-00H0614-02H0487-00H0486-00H0489-00Ordering infOrmaTiOn RTS2 Multi-Signaling AccessoryRTS2-AOSMulti-Signaling Accessory with Strobe AOSAdd-On StrobeinnOvairfLex ducT SmOke deTecTOrSD4120 4-Wire Photoelectric Duct Smoke Detector D4120W4-Wire Watertight Duct Smoke Detector D4P120 4-Wire Power Board-Only Component D4S4-Wire Photoelectric Additional SensorOTher acceSSOrieS RTS151 Remote T est/Reset StationRTS151KEYKey-Activated Remote T est/Reset Station APA151 Piezo Annunciator RA100ZRemote Annunciator Alarm SENS-RDRSensitivity ReaderRTS2/AOSRTS2-AOS。
易安电子产品说明书
Eaton 189884Eaton Moeller® series PKZM01 Motor-protective circuit-breaker, 660 V 690 V: 0.55 kW, Ir= 0.63 - 1 A, IP20General specificationsEaton Moeller® series PKZM01 Motor-protective circuit-breaker189884PKZM01-1-EA401508187880293 mm 90 mm 45 mm 0.261 kgCE Marked RoHS conformProduct NameCatalog Number Model Code EANProduct Length/Depth Product Height Product Width Product Weight Compliances0.25 kW0.63 AThermomagnetic15.5 A0.12 kWBuilt-in device fixed built-in technique Phase failure sensitiveScrew connectionThree-pole690 V50 kA1 A5.33 W15.5 A1 A690 VPush button Motor Starters in System xStart - brochureSave time and space thanks to the new link module PKZM0-XDM32MESwitching and protecting motors - catalogProduct Range Catalog Switching and protecting motorseaton-manual-motor-starters-characteristic-characteristic-curve-008.eps eaton-manual-motor-starters-characteristic-characteristic-curve-009.eps eaton-manual-motor-starters-characteristic-characteristic-curve-005.epsDA-DC-00004883.pdfeaton-manual-motor-starters-circuit-breaker-pkzm01-dimensions.eps eaton-manual-motor-starters-circuit-breaker-pkzm01-3d-drawing-002.epseaton-general-ie-ready-dilm-contactor-standards.epseaton-manual-motor-starters-mounting-3d-drawing-002.epsDA-CE-ETN.PKZM01-1-EAIL034045ZUWIN-WIN with push-in technologyDA-CD-pkzm01DA-CS-pkzm01Rated operational power at AC-3, 380/400 V, 50 Hz Overload release current setting - minSwitch off techniqueAdjustment range undelayed short-circuit release - min Rated operational power at AC-3, 220/230 V, 50 Hz Device constructionFunctionsElectrical connection type of main circuitNumber of polesRated operational voltage (Ue) - minRated short-circuit breaking capacity Icu at 400 V AC Rated uninterrupted current (Iu)Power lossAdjustment range undelayed short-circuit release - max Overload release current setting - maxRated operational voltage (Ue) - maxActuator typeDegree of protection BrochuresCatalogsCharacteristic curveDeclarations of conformity DrawingseCAD modelInstallation instructions Installation videosmCAD modelEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIP20。
全自动生化仪简介
OLYMPUS AU系列全自动生化仪
AU400
AU2700
AU640
AU系列各型号生化仪对比
机型
试剂位 R1/R2
项目 速度 样本 (双) 无 ISE (ul)
R1 (ul)
R2 (ul)
反应液 (ul)
AU400 48/48
AU600 AU640
48/48 48/48
AU2700 48/48
CX9
24
33 900 3-25
LX20
41
70 800 3-25
Beckman系列生化仪性能特点
光源采用长寿闪烁式氙灯,无需保养和 更换。
比色杯直径0.5cm,因数法检测时需要在 理论因数的基础上*2。
酶类项目采用因数法时免校正。 使用标准液定标一个项目,需要一个标
准液位置,不能重复使用。
AU400采用干式空气浴,AU640采用恒温液循 环加温方式,升温均匀。
带冷藏的48位试剂盘,R1/R2试剂位置可随意 设置,避免R1/R2不同盘造成的试剂位浪费。 单数为外圈,放30ml小瓶,双数为内圈,可放 60ml的大瓶。
除AU600外,都具有样本预稀释(5-100 倍)功能,可以检测高浓度标本,并且 可以通过预稀释降低试剂用量。
日立系列生化仪性能特点
从紧凑型的7020到组合式的7600,都具有强大的功能, 可以满足各种项目的检测需要。
开放式的试剂系统。试剂和样本微量化。
灵活的反应时间,可自由控制。
仪器线性宽,量程0-32000。
同样一个项目可以同时输入血清和尿液两套参数(不 占试剂通道)。
全反应过程监测,可以察看任意时间反应曲线 和吸光度,便于发现和解决问题。
Sysmex XN系列和SP-10维护指南说明书
Sysmex XN Series and SP-10 MaintenanceDocument Number: RHEAHS14010MUL Revision Number: 2.50 Document Type: Procedure Effective Date: 6/17/2022 2:26:04 PM Location: 3. APL Folder Structure\Hematology HE\CBC and Differential\Sysmex XN - 59\Edmonton ZoneRHEAHS14010MUL Sysmex XN Series and SP-10 MaintenanceAPPLICABILITYThis document is applicable to APL staff at the following Edmonton Zone sites: GNH,RAH, SGH and UAH.PURPOSEThis procedure describes how to perform the daily clean, shutdown, startup and maintenance (daily, weekly and monthly) of the Sysmex XN series and SP-10 analyzers.MATERIALSPROCEDURE4.1. XN Series MaintenanceAll maintenance procedures must be signed off on the Sysmex XN Series Maintenance form.4.1.1. Daily4.1.2. Weekly4.1.3. Monthly4.1.4. Every Six Months4.1.5. Yearly or As Needed4.2. SP-10 Maintenance (RAH and UAH only)All maintenance procedures should be signed off on the Sysmex SP-10 Maintenance form.4.2.1. DailyWhen in shutdown, remove the trap chamber from the right side of4.2.2.Weekly4.2.3.As NeededREFERENCES1. Sysmex XN-1000 / XN-2000 Automated Hematology Analyzers CLSI Procedure, Document number:1004-LSS. Rev. 1, March 20132. XN Series (For XN-1000 system) Instructions for Use (North American Edition), November 2012.3. SP-10 Instructions for use.4. XN-9000 Instructions for use.RELATED DOCUMENTSRHEAHF14010MULA Sysmex XN Series MaintenanceRHEAHS14006MUL Sysmex XN Series - Performing QCRHEAHS14019MUL Sysmex XN Series - Manual Shutdown and StartupRHERHS00004MUL Inter-Instrument Variability for Hematology Coagulation and Special Coagulation AnalyzersRHERHF00002MUL Hematology Inter-Instrument Variability Excel WorksheetRQMPCS14000MUL Annual Autovalidation CheckRHEAHF14010MULB Sysmex SP-10 MaintenanceHE24-097 Evaluating Quality Control using the Beyond Care Quality Monitoring BCQM System。
安捷伦系列芯片简介(鼠标专用ic)
安捷伦系列芯片简介安捷伦和安华高安捷伦科技(NYSE:A)是由美国惠普公司战略重组分立而成的,其业务重点包括通信、电子及化学分析与生命科学。
1999 年11月18日, 安捷伦科技以代码“A”在纽约股票交易所挂牌上市。
虽然在除了光学传感之外的领域里,安捷伦也取得了巨大的成就。
但是对于广大玩家来说,大家提起安捷伦(AGILENT),还是首先想起它作为世界上最著名的鼠标用光学/激光感应器材的生产厂家。
的确,在上世纪90年代和本世纪初的这段时间里,安捷伦几乎是高档光电/激光鼠标芯片的代名词,作为安捷伦历史悠久的合作伙伴,在上世纪末,在MS和安捷伦勾搭上之前,LOGITECH几乎是垄断了高端外设的市场。
而在山的那一边,那条叫RAZER的小蛇,当时连牙还没有长全呢~在2005年8月,投资公司Kohlberg Kravis Roberts & Co.会同风险投资商Silver Lake Partners,以26.6亿美的价格并购了安捷伦科技。
并购后,新成立了公司A V AGO,也就是现在大家所说的安华高,并且号称全球最大的非上市独立半导体公司。
Avago Technologies 拥有5,500多种系列产品,主要应用于无线和有线通信、工业、汽车、消费电子及存储和计算机等广阔的应用领域和终端市场。
它在光电耦合器、红外线收发器、光通信器件、打印机ASIC、光学鼠标传感器和运动控制编码器等领域一直保持市场前3名的领导地位。
通过并购,安华高遗传了安捷伦全部的研发能力和市场网络,并且将其在光电鼠标处理芯片上的技术优势地位继续延续。
在下面的文章中,在介绍产品的时候,我决定仍然使用安捷伦这个名字,也当作是对它的一个怀念和敬意吧首先补充一点小知识,有关激光引擎和光学引擎的激光引擎和光学引擎的区别~~~从原理上来讲是类似的,但是由于激光是相干光~ 所以具有比LED光源更好的特性~ 安捷伦自己的描述是这样的A, LED光学引擎的原理示意图B,激光引擎的原理示意图C, 激光比LED引擎的优越性D, 激光可支持更多的表面激光引擎可以支持的表面包括:纸,木材,包装纸,粗斜纹棉布,棉布,榻榻米(!),地毯(!),金属,瓷砖,塑料,福米卡塑料(!?),网格(!!!)LED引擎可以支持的表面包括:纸,木材,包装纸,粗斜纹棉布,棉布,纯黑表面安捷伦到目前为止,所出产的鼠标应用方案如下:LED光学引擎系列型号系列描述ADNS-2030 无线系列低功率光学传感器,为无线应用优化ADNS-2051 有线系列中频光学传感器,为有线/无线应用ADNS-2610 有线(小型封装)入门级,小型封装光学传感器,为普通鼠标应用ADNS-2620 有线(小型封装)入门级,小型封装光学传感器,性能提高ADNS-3040 无线系列超低功率光学传感器,为无线应用优化ADNS-3060 有线系列高性能光学传感器ADNS-3080 游戏系列高分辨率光学传感器,为游戏应用ADNS-3530 MINI系列 MINI系列低功率,芯片-基板-LED整合设计光学传感器,为无线应用设计ADNS-3550 MINI系列 MINI系列低功率,芯片-基板-LED整合设计光学传感器,为无线应用设计ADNS-5000 有线系列基于LED的导航传感器ADNS-5020-EN 有线(小型封装)小型封装光学传感器,较入门级性能有所提高ADNS-5030 无线(小型封装)低功率,小型封装光学传感器,为无线应用设计ADNS-5050 有线系列性能提升的基于LED的导航传感器LaserStream 激光引擎系列型号系列描述ADNS-6000 有线系列高性能激光鼠标传感器ADNS-6010 游戏系列高分辨率激光鼠标传感器,为游戏设计ADNS-6090 专业游戏系列增强型游戏级激光传感器ADNS-6530 MINI系列 MINI系列低功率,芯片-基板-LED一体化设计激光传感器,为无线应用设计ADNS-7010 休闲游戏系列休闲型游戏级激光传感器ADNS-7050 无线系列低功率激光传感器ADNS-7530 无线系列整合型,入门级,小型封装激光传感器ADNS-7550 有线系列整合型,入门级,小型封装激光传感器目前,以LOGI为主的厂家,包括MS等,以及国产的双飞燕等,均广泛使用安捷伦的芯片进行一下总结:作为业界的领袖企业,安捷伦(安华高)的芯片发展,也代表这整个业界的技术发展方向。
艾克尔坎智能水泵使用指南说明书
SubmerSible pumpSP .O. Box 4, 6987 ZG Giesbeek, the Netherlands T +31 313 88 02 00F+31 313 88 02 99E *******************I manualAll it takes for environmental research36.1 mm 125.5 mm 20.5 mm20.5 mm36.1 mm 125.5 mmOn these operating instructionsIf the text follows a mark (as shown on the left), this means that an important instruction follows.If the text follows a mark (as shown on the left), this means that an important warning follows relating to danger to the user or damage to the apparatus.The user is always responsible for its own personal protection.1.Description and use of the submersible pumpsDo not use the pumps until first reading these instructions. Keep these instructions in a place accessible to all users.The Gigant and Booster pumps are very small submersible centrifugal pumps. They have a very strong ABS housing and a stainless steel impeller and axle. A small yet powerfull motor rotates the impeller. Centrifugal action then pressurizes the water. The water moves upward alongside the ABS motor-housing to the tubing-nipple on top of the pump. The pump can be applicated in wells as small as 38 mm in diameter.The Gigant pump can be used to pump water from a depth of maximum 9 meter pressure height. If the water table is deeper you may place a Gigant pump in-line with one, two or maximum three Booster in-line pumps. By doing this, the pressure head lift will be 18, 27 or 36 m respectivily. Simply fit a tube on the Gigant pump then connect this tubing to the bottom nipple of a Booster in-line pump. Subsequently fit a tube to the top nipple of the in-line pump to reach the earth’s surface. If pressure height is still insufficient, add more in-line pumps.!☞☞ContentsOn these operating instructions ..........................................................................................................................................................................11. Description and use of the submersible pumps .....................................................................................................................................12. Tubes .......................................................................................................................................................................................................................33. Performances .......................................................................................................................................................................................................34. Decontamination and maintenance ...........................................................................................................................................................45. Use of crimp splices and extension cables ................................................................................................................................................46. Sampling limitations .. (4)The Gigant and Booster pumps may be used to develop and purge small wells. Pinched of to a low flow rate the pumps may be used for sampling too (use adjustable pinch clamp 12.20.97). Till a depth of 11 m with max. two pumps the external pump connection of the 12.25 peristaltic pump can be used. In this way the rate of revolutions can be adjusted electronically.Centrifugal pumps should not be used for in-line filtration with filters of 0.45 micron.This pump has a powerfull yet very small motor (that is why you can put it in a very small well). At the same time it is very cheap so that you may dispose of the pump after a sampling event, thus avoiding the risk of cross-contamination.The relative simple contsruction brings some limitations:❒ This pump is meant for use with water. Chemicals may attack the ABS housing, the stainless steel axle and impeller, the PVC cable, or the tiny nitrile seal. If pumping (water with) other liquids, check for chemical compatibility. Especially the ABS housing does not resist most types of fuel.❒ The pump has been run for days continuously, but it is recommended that running periods should be restricted to a maximum of 15 minutes and then switched off for 15 minutes.❒ Always keep a spare pump in reserve.❒ Do not run dry. Immerse in-line pump in water, before use.❒ Do not place the pumps on a distance of more than 1 meter of each other (see figure 1).❒ Before starting pumping all pumps must be below the water level. While pumping be sure that the lowest pump is always under water. When the lowest pump is drawing air one has to stop pumping until the water level has reached a sufficient height.❒ Avoid using these pumps with a voltage on the pump lower than 12Volt. The pump does not perform as it should and the lifecycle is shortened or the pump will burn out. A direct cur-rent motor is able to resist overvoltage better than undervoltage! ❒ Avoid using the pump very deep under the water table (high pressures will cause water to enter the motor-housing). If you would like to sample very deep under the groundwater level you should replace the lowest (Gigant) pump by a Booster pump with a very long tube attached (see figure 2).❒ Avoid pumping water with a high percentage of sand. Sand may clog the pump. Gravel will block the impeller. Always use the sieve (at the bottom of the Gigant pump) and keep it clean.❒ Do not block the water flow by kinking or plugging the tubing or connecting an in-line filter (the water flow cools the pump motor). It is however possible to diminish the water flow temporary by partially squeezing the tube.6V Battery 12V BatteryTubeExtension cable (12.12.12)Cable splicing Crimp splice (12.12.11)Booster pump (12.12.08)Water level e.g. - 20 mGigant pump (12.12.06)Deepest level e.g. -23 mFigure 12. Tu b es❒ The nipple(s) on the pump normally takes tubes with an inside diameter of 10 mm.❒ Inside the nipple you may use tube with an outside diameter of 8 mm (not recommended; too loose for pulling).❒ With the small adapter fitted you can use a garden hose (13 mm inside diameter) or PE tube 12 x 16 mm (art. no.: 12.20.16). You can use a cigarette lighter or flame at a distance to soften the end of the PE tube.The flow capacity may be optimized by using large diameter tube. We measured the following performances:• With 4 meters of 6 mm tube and 2 m pressure head lift, the flow rate was only3.5 l/min.• With 10 mm tube 7 l/min.• With 12 mm tube 9 l/min!3. PerformancesTests resulted in the following:❒ Two pumps with 25 m cable on a peristaltic pump 12.25 has a maximum pressure head lift of 11.5 m (the cable must be shortened because this points to a too low voltage at the pumps).❒ The same pumps directly powered by a 12 V battery gives a (still too low) pressure head lift of 15 m.❒ The same pumps on a 18 V battery gives a pressure head lift of 23 m!The performance and service life of the pump is strongly affected by the power supply. The power consumption is 12 Volt 3 Amps (36 Watt) per pump.❒ A long thin extension cable will severely diminish performance. When using two or more pumps this must be compensated. The pumps must receive at least 10 Volts. Use a thick extension cable with PVC coating (minimal 2 x 1.5 mm 2).❒ When using two pumps or more with more than 15 m cable it is neccessary to connect a 12 Volt and a 6 Volt battery in series (or with 4 pumps two 12 Volts batteries!). In this way you are capable of sending 18 (or 24) Volts to the pump. When reaching the pumps a gentle but effective 12 to 15 Volt will remain at the pump and they will perform well.❒ If you use the peristaltic pump 12Vdc with flow rate controller for external pumps(article no.: 12.25) the performance of the pump will decrease with about 30%. Due to losses in electronic circuitry. Only two pumps can be connected to the peristaltic pump with art. no.: 12.25.❒ Extension cables are available with a length of 100 m (2 x 1.5 mm 2). Water tight crimp splices are available to connect cables.❒ Polarity does not influence the performance of the pumps. Irrespective of the direction of turning the pumps will perform well.TubeBooster pump (12.12.08)Water level e.g.-20 mSampling depth e.g. -60 mFigure 2☞4. Decontamination and maintenanceAfter use, the pumps can be decontaminated with warm water and a detergent (art. no.: 20.05.29). Always give the pump a final rinse with clean water.Penetrated volatile components in the synthetic material of the pumps will only disappear after a long period of storage of the pumps in a ventilated, heated room. Do not heat the pump above 60 °C. When storing the pump in a closed con-tainer (e.g. a plastic bag) dry the pump thoroughly.If in doubt, renew pump. Analysis costs are much higher than the price of a pump with tube ! D o n o t store the pumps near apparatus or jerrycans with fuel. Benzene, toluene xylene etc. are easily sorbed and will influence analysis results.The Gigant pump is fitted with a strainer to filter out larger particles. Please check for clogging to prevent performance loss. No further maintenance is required.The pumps have been tested as sampling tools for organics and inorganics. When decontaminated in water prior to use, they are found to be effective and reliable sampling pumps.❒ They lift the water, instead of applying suction, thus reducing the risks of loss of volatiles and alteration of the pH.❒ The Gigant and Booster pumps are easy to install. They do not need a compressor or generator and are so cheap that they do not need to be re-used. In this way the risk of cross-contamination to other wells can be eliminated. Decontamination procedures between samplings are avoided.❒ 12 Volt is safe, even in combination with water.❒ The pump and tube can stay in the monitoring well. (However no full long term test results are available to this sub-ject). When, after a sampling procedure, you want to dedicate the pump and tube to the well, it is advised to lift the pump, ply the tube and re-insert the pump together with the tube into the well in such a way that the pump will be positioned just above the waterlevel. In this way long term contact between the well water and the pump housing is avoided. You may also store pumps and tubes in labelled bags.5. Use of crimp splices and extension cablesWhen installing the sealed crimp splices (art. no.: 12.12.11) on the extension cable (art. no.: 12.12.12) proceed as follows:1. Strip wires 7.5 mm and insert into crimp barrel.2. Match the colour of the splice with the colour of the crimp cavity on the crimping tool.3. Crimp.4. Heat crimped splice with heat gun until tubing recovers and adhesive melts and flows.6. Sampling limitationsThe insulation of the connection wire contains di-isononylphtalate or di-isodecylphtalate. This may interfere with analyses performed to determine the concentration of these plasticizers in e.g groundwater.1.2.3.4.Figure 3☞☞Nothing in this publication may be reproduced and/or made public by means of print, photocopy, microfilm or any other means without previous written permission from Eijkelkamp Agrisearch Equipment.Technical data can be amended without prior notification.Eijkelkamp Agrisearch Equipment is not responsible for (personal) damage due to (improper) use of the product.Eijkelkamp Agrisearch Equipment is interested in your reactions and remarks about its products and operating instructions.。
AMI310
20 mm
温湿度探头
湿度 : 电容式传感器 温度 : 铂电阻 PT100 1/3 DIN 级 标准型 工业塑料握把 ( -40 ~ +85 °C ) 高温型 工业塑料握把 ( -40 ~ +85 °C ) 和不锈钢探头
无线传输 最远距离为 10 m
量程
精确度
分辨率
t63
相对湿度 0 ~ 100 %RH
MDP2500 : ±2500 Pa , 允许过压 : 500 mbar
MDP10000 : ±10000 Pa , 允许过压 : 1200 mbar
MDP500M : ±500 mbar , 允许过压 : 2 bar
MDP2000M : ±,000 mbar , 允许过压 : 6 bar
热线风速探头 : NTC 负温系数热敏电阻 ( 风速 ), Pt100 1/3 DIN 级 ( 环境温度 )
Ø 70 和 100 mm 叶轮风速探头 : 霍尔传感器 ( 风速 ), Pt100 A 级 ( 环境温度 )
Ø 14 mm 小叶轮风速探头 : 接近度传感器 ( 风速 ), Pt100 A 级 ( 环境温度 )
温湿度探头 : 电容式传感器 ( 湿度 ), Pt100 1/3 DIN 级 ( 环境温度 )
电源供应 ............................... 电池 4 节 1.5 VDC 五号电池
操作环境 ............................... 中性气体或空气
操作温度 ............................... 从 0 到 +50 °C
储存温度 ............................... 从 -20 到 +80 °C
Extech MA3110 600A 3000A AC True RMS 灵活电流计说明书
USER MANUAL3000A TRUE RMS AC Flexible Clamp Meter Model MA3110Additional User Manual Translations available at IntroductionThank you for choosing the Extech Model MA3110 Flexible AC Clamp meter with automatic ranging, data hold, and auto power OFF. The MA3110 is a professional CAT III 1000V instrument that measures up to 3000A AC RMS. The MA3110 also measures DC and AC Voltage, Resistance, Capacitance, Diode, and Continuity (beeper). This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website() to check for the latest version of this User Guide, Product Updates, Product Registration, and Customer Support.Features∙600A and 3000A AC True RMS Current Measurement ranges∙AC (True RMS) and DC Voltage Measurements∙Automatic ranging∙Meets IEC61010-1, 3rd Edition (2010) CAT III 1000V Safety requirements.∙Resistance, Capacitance, Diode, and Continuity Beeper∙Data Hold feature freezes displayed reading∙6000 count large scale LCD display∙Convenient Flexible Clamp with locking mechanism∙8mm (0.3”) coil diameter for measuring in tight spaces∙Coil length 300mm (11.8“)∙Auto Power OFF after 15 minutes of inactivity∙Overload Protection for most ranges∙Durable, long-lasting components, enclosed in strong, lightweight ABS-plastic housing.Safety InformationTo ensure the safe operation and service of the meter, follow these instructions closely. Failure to observe warnings can result in severe injury.Precautions and Preparations for Measurements∙Ensure that the batteries are connected in the correct polarity and placed in the battery compartment (rear) correctly.∙Place the red and black test leads into the proper input terminals before making measurements.∙Remove the test leads from the circuit under test when changing the measurement ranges. ∙Do not exceed the maximum rated voltage and current on the meter input terminals.∙Remove the battery if the meter is to be stored for long periods∙Replace the test leads only with ones rated for CAT III 1000V or better.∙The meter has an automatic power OFF (APO) utility that switches the meter OFF after 15 minutes of inactivity. Press any key to wake the meter. To disable this feature, press andhold the M (mode) button while switching the meter ON.WarningsWarnings identify hazardous conditions and actions that could cause BODILY HARM or DEATH. ∙Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible.∙If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.∙To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.∙Verify the meter operation by measuring a known current. If in doubt, have the meter serviced.∙Do not apply more than the rated voltage/current as marked on the meter.∙To avoid false readings that can lead to electric shock and injury, replace battery as soon as the low battery indicator appears.∙Do not use the meter in or around explosive gas or vapor.∙Do not use a flexible current sensor if the inner copper wire of the flexible cord is visible.∙De-energize the installation under test or wear suitable protective clothing when placing or removing the flexible current probe from a test setup.∙Do not apply/remove the flexible current probe to/from UNINSULATED HAZARDOUS LIVE conductors that may cause electric shock, electric burn, or arc flash.CAUTIONSCAUTIONS identify conditions and actions that could cause DAMAGE to the meter or equipment under test. Do not expose the meter to extremes in temperature or high humidity.Safety Symbols that are typically marked on meters and instructionsCaution: Do not apply voltage or current to the input terminals or clamp thatexceeds the specified rangesCaution: Risk of electric shock!Equipment protected by double or reinforced insulationConforms to EU directivesDo not discard this product in household trash.AC measurementEarth groundPER IEC1010 OVERVOLTAGE INSTALLATION CATEGORYOVERVOLTAGE CATEGORY IEquipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over-voltages to an appropriate low level.Note – Examples include protected electronic circuits.OVERVOLTAGE CATEGORY IIEquipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation.Note – Examples include household, office, and laboratory appliances.OVERVOLTAGE CATEGORY IIIEquipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.Note – Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation.OVERVOLTAGE CATEGORY IVEquipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.Note – Examples include electricity meters and primary over-current protection equipment.Meter Description1.Flexible Current Clamp2.Clamp Lock Mechanism3.6000-count LCD Display4.Power button5.Data Hold Button6.MODE (M) Button7.Function Switch (-) test lead input terminal9.Positive (+) test lead terminalDisplay IconsH Data HoldAUTO Automatic Range modeAC Alternating CurrentDC Direct CurrentLow battery icon (flashing when measurements cannot be expected to be in-specification)Continuity alert (beeper)V Unit for Voltage measurementsA Unit for Current measurementsΩ, KΩ, MΩUnits for Resistance measurementsnF, uF Units for Capacitance measurementsDiode measurementsOL ‘Overload’ for over range measurements (voltage, current and resistance) - Minus symbol (negative) when the measurement value is negativeMeter PowerThe meter is powered by two (2) 1.5V ‘AALow battery indicationalthough in-specification measurements can still be made temporarily. When the low battery icon begins blinking, in-specification measurements are no longer supported and batteries must be replaced before further measurements can be made. Refer to the battery replacement procedure in the maintenance section.Automatic Power OFFThe meter switches OFF automatically after a 15-minute period of inactivity. To disable the Auto Power OFF feature:∙With the meter power OFF, press and hold the Mode (M) button while powering the meter ON.∙The APO feature is now disabled and the meter will not shut off automatically.∙Note that the next time the meter is powered up, the Auto Power OFF function will be enabled again and the user will have to repeat the Auto Power OFF disable instructionsto disable this function when desired.Data HoldPress the H (HOLD) button with the meter ON to freeze the displayed reading. The H icon will appear along with the held reading. Press the H (HOLD) button again to release the HOLD feature. The H icon will switch OFF and the meter will show real time readings.DC and AC Voltage Measurements1.Connect the black test lead into the COM terminal.2.Connect the red test lead into the ‘V’ terminal.3.4.Put the function switch to the ‘V’ position.5.The display will show the ‘AUTO’ icon (Auto Range mode).6.Press the M (MODE) button to select AC or DC voltage.7.Press the test leads across the circuit under test and read the voltage on the display.8.In the Auto Range mode, the meter will automatically select the optimal range. AC voltagemeasurements are True RMS readings.1.Switch the meter OFF and switch OFF power to the device under test.2.Switch the meter ON and select ‘A’ with the function switch. The display will show theautomatic range icon (AUTO).3.Turn the knurled clamp lock mechanism counter-clockwise to release the flexible clamp.4.Fully enclose only one conductor of the device undertest with the flexible clamp probe (see accompanyingdiagrams). Do not attempt to measure current higherthan the specified current limit.5.Re-lock the clamp turning the clamp lock clockwise.6.Switch power to the device under test ON. Never move fingers above the LCD whenrunning a test.7.Read the current value in the display. The meter will automatically select the appropriaterange (600.0A and 3000A).1.Connect the black test lead into the COM terminal.2.Connect the red t est lead into the ‘Ω’ terminal.3.4.Put the function switch to the ‘Ω’ position.5.The display will show the ‘AUTO’ icon (Auto Range mode).6.Press the M (Mode) button to select resistance Ω mode.7.Press the test leads across the circuit under test and read the resistance on the display.8.In the Auto Range mode, the meter will automatically select the optimal range.CAUTION: Disconnect power to the circuit or device under test when making continuity measurements1.Connect the black test lead into the COM terminal.2.Connect the red test lead into the ‘ohms’ terminal.3.Power the meter using the power button .4.Put the function switch to the ‘ohms’ position.5.The display will show the ‘AUTO’ ico n (Auto Range mode).6.Press the M (Mode) button to select continuity mode.7.The display will show “MANU” icon (Manual Range mode).8.Press the test leads across the circuit under test. The meter will beep and the display willshow the continuity symbol when the resistance is < 20 ohms.Diode MeasurementsCAUTION: Disconnect power to the circuit or device under test when making diode measurements1.Connect the black test lead into the COM terminal.2.Connect the red test lead into the ‘Ω’ terminal.3.Power the meter using the power button .4.Put the function switch to the ‘Ω’ position.5.The display will show the ‘AUTO’ icon (Auto Range mode).6.Press the M (Mode) button to select diode mode. The display will show the manualmode symbol (MANU).7.When connected as shown in test position 1 a forward current flow is established andthe approximate diode forward voltage (VF) value is displayed. If the diode under test isdefective ‘0.000’ (short circuit) or ‘OL’ (open circuit) will display.8.When connected as shown in test position 2 a reverse polarity check is made. If the diodeunder test is good, ‘OL’ will be displayed. If the diode is defective ‘0.000’ or other valueswill be displayed. Proper diode testing should include both polarity measurements.Capacitance MeasurementsCAUTION: Discharge the capacitor under test before taking any capacitance measurements1.Connect the black test lead into the COM terminal.2.Connect the red test lead in to the ‘Ω’ terminal.3.Power the meter using the power button .4.Put the function switch to the ‘Ω’ position.5.The display will show the ‘AUTO’ icon (Auto Range mode).6.Press the M (Mode) button to select the capacitance mo de.7.Press the test leads across the circuit under test and read the capacitance on the display.8.In the Auto Range mode, the meter will automatically select the optimal range.MaintenanceCleaning and StoragePeriodically wipe the case with a damp cloth and mild detergent; do not use abrasives orsolvents. If the meter is not to be used for 60 days or more, remove the batteries and store them separately.Battery Replacement1. Remove the screw that secures the rear battery compartment.2. Remove the battery compartment cover.3. Replace the 2 ‘AAA ’ 1.5V batteries observing correct polarity.4. Re-attach the battery compartment cover.5. Secure the battery compartment with the screw.Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold.Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment.SpecificationsSpecifications tested under environmental conditions of RF field strength < 3V/M and frequency < 30MHzGENERAL SPECIFICATIONSClamp Flexible type with locking mechanism8mm (0.3”) coil diameter300mm (11.8”) flexible cable lengthDisplay 6000 count LCD with multi-function indicators33.5 x 18.7mm (1.3 x 0.7”) display sizeAuto range 600.0A and 3000A ACSampling rate0.5 to 1 secondLow Battery indication Low voltage display alertsOver-range indication‘OL’ di splayAC bandwidth 50/60Hz (sine wave)AC response True RMSOperating Temperature and Humidity0~50︒C (32~122︒F); 80%RH maximumBattery Two “AA A” 1.5V batteriesBattery consumption 21.1mA approximatelyAuto power OFF After approx. 15 minutes of inactivityDimensions (W x H x D)290 x 135 x 27.8 mm (11.4 x 5.3 x 1.09”)Weight 208g (0.46 lbs.) without batterySafety Standards IEC61010-1, 3rd Edition (2010); Pollution degree 2; Altitude 2000m(6562’) maximum; Indoor use onlyVoltage/Category Rating 1000V CAT III, 600V CAT IVCurrent Rating3000AProbes Listed IEC61010-031 Probes OnlyCopyright © 2016 FLIR Systems, Inc.All rights reserved including the right of reproduction in whole or in part in any formISO-9001 Certified。
瑞萨电子MCU电能计量解决方案
整个系统的框图
N
电能计量
L
芯片
5V
220V~ 转换电路
将数据
I/O
光耦 按照协
议输出
INTP
78F9202
脉冲输出用于校表
I/O
I/O 按键输入,用 于功能切换
5V
4 © 2010 Renesas Electronics Corporation. All rights rese片
零线
火线
5 © 2010 Renesas Electronics Corporation. All rights reserved.
锰铜片
调试接口 通信口
光耦
电能采集模块实物图
反面图片
78F9202
BL0930
6 © 2010 Renesas Electronics Corporation. All rights reserved.
通信部分
由按键切换校表和 正常工作两种状态
通过光耦电路将波形信号 通过按照协议单线输出
通信插座
9 © 2010 Renesas Electronics Corporation. All rights reserved.
78F9202MCU部分
使用外部晶振
10 © 2010 Renesas Electronics Corporation. All rights reserved.
2路外部中断口 4路10位A/D转换器
POC、LVI
功能和特点 主要功能: 实时测量家电的即时功率和耗电量
特点: 1. 使用方便,通过单线通信将用电量和功率数据传送给主机 2. 实现简单易行的软件校表功能 3. 体积很小,便于嵌入家电控制板内或者及进行系统集成
Milli-Speed 系列速度开关 M300M1V10AI 产品规格参数表说明书
Milli-Speed 系列速度开关旋转设备速度监测防爆认证:ATEX, IECEx 及CCCEx 20, 21 & 22 粉尘环境0, 1 & 2 气体环境应用:4B Milli-Speed 系列速度开关输出 4 - 20 mA 模拟信号,非常方便监测斗提机、输送机、旋转阀 、混合机、风机、粉碎机等旋转设备的欠速、皮带打滑等危险工况,客户可选择0~100%范围内任一点自由监测。
标定简便快速,适合各种极端工况。
使用方法内置先进电感元件,探测金属目标的转动。
转动目标可以使用金属螺栓头,但配合 4B 的Whirligig® 通用轴端速度传感器安装套件进行速度监测将更精准,而且安装更简便快捷。
客户可以将安装套件以螺栓方式与目标轴端(螺纹尺寸M12x1.75),也可以采用高磁连接器(MAG2000M ,连接螺纹M12x1.75) 连接安装套件然后将高磁联结器直接吸附在目标轴端。
主要特性4-20mA 模拟信号输出•可以螺栓连接也可以磁性连接•环路供电(2 线制)•全封装结构,可进入水中•适配通用轴端速度传感器安装套件Whirligig®•方便使用SpeedMaster ™速度大师进行传感器测试与检查适配附件:•WG4A-BR –通用轴端速度传感器安装套件,4目标•WG2A-BR –通用轴端速度传感器安装套件,2目标•MAG2000M –高磁联结器目标转轴MAG2000M 高磁联结器MilliSpeed 传感器Whirligig通用轴端速度传感器安装套件Whirligig 安装套件安全防护罩技术规格参数产品型号M300M1V10AI电源电压:17 -30 VDC 负载:500 Ohm (典型值)可测转速范围:20 -2,000 PPM (每分钟脉冲数),PPM=RPMx 目标数理想目标:黑色金属目标探测范围:≤ 8 mm 标定:磁标定输出:4-20mA 线性的模拟信号输出1.超速= 20mA (标定速度的123%及以上速度)2.标定的标准速度= 17 mA (100%)3.零速= 4mA (标定速度的0-10)输出精度:+/-0.2 mA 响应时间:<1 秒(典型值)认证条件下操作温度:-15°C ~+50°C 分满量程辨率:0.3% (22 微安)防护等级:IP66 粉尘及水封(全封装结构)Certificates and approvals:II 1G Ex ma IIC T4 Ga 1D Ex ma IIIC T 200110°C Da IP66 Tamb -15°C to +50°C Ex ma IIC T4 Ga Ex ma IIIC T 200110°C Da IP66 Tamb -15°C to +50°C 0 Ex ma IIC T4 Ga X Ex ma IIIC T 200110°C Da X OT -15 Дo +50Ex maD 20 T110°C电气连接Milli-Speed 速度传感器负载/ PLC 输入端(500 Ohm –典型值)蓝色线黑色线+-电源电压17 ~30 VDC注意: 电源无极性要求,可与传感器的两根出线任意连接4 –20 mA 输出周身螺纹尺寸: ISO M30 x 1.52 x 锁紧螺母3m 电缆2 线20 AWG 线规电缆6.2mm注意:所有尺寸包含公制mm 和英制英寸蓝色LED 指示灯(有速度脉冲时闪烁)外形尺寸。
AXIS M1125-E网络摄像头说明书
DatasheetAXIS M1125-E Network CameraOutdoor,affordable and feature-rich with HDTV1080pAXIS M1125-E is an outdoor-ready day and night camera delivering HDTV1080p video in up to25/30frames per second.The camera is fitted with an IR-corrected,varifocal and easily exchangeable CS-mount lens with DC-iris. AXIS M1125-E includes Axis Zipstream technology that significantly reduces bandwidth and storage requirements.The camera supports WDR-Forensic Capture,providing video optimized for forensic purposes in scenes with complex light conditions.The lightweight IP66-and IK10-rated camera supports Power over Ethernet to simplify installation,microSD card slot for edge storage,digital input and output ports for connection with external equipment.>Outdoor-ready>HDTV1080p in up to25/30fps>Varifocal CS-mount lens>WDR-Forensic Capture>Axis Zipstream technologyAXIS M1125-E Network Camera CameraImage sensor Progressive scan RGB CMOS1/3"Lens Varifocal,IR corrected,CS-mount,DC-iris,3–10.5mmHorizontal field of view:91°–32°Vertical field of view:49°–18°Day and night Automatically removable infrared-cut filterMinimum illumination Color:0.25lux F1.4 B/W:0.05lux F1.4Shutter speed1/66500to1s VideoVideo compression H.264Baseline,Main and High profile(MPEG-4Part10/AVC) Motion JPEGResolution1920x1080to160x90Frame rate Up to25/30fps in all resolutionsVideo streaming Multiple,individually configurable streams in H.264and Motion JPEGAxis Zipstream technology in H.264Controllable frame rate and bandwidth,VBR/ABR/MBR H.264 Image settings WDR–forensic capture:up to120dB depending on scene,manual shutter time,compression,color,brightness,sharpness,contrast,white balance,exposure control(including automaticgain control),exposure zones,fine tuning of behavior at lowlight,rotation:0°,90°,180°,270°,aspect ratio correction,textand image overlay,privacy mask,mirroring of imagesPan/Tilt/Zoom Digital PTZNetworkSecurity Password protection,IP address filtering,HTTPS a encryption,IEEE802.1X(EAP-TLS)a network access control,digestauthentication,user access log,brute force delay protection,signed firmwareSupported protocols IPv4,IPv6USGv6,HTTP,HTTPS a,SSL/TLS a,QoS Layer3DiffServ, FTP,SFTP,CIFS/SMB,SMTP,Bonjour,UPnP TM,SNMP v1/v2c/v3 (MIB-II),DNS,DynDNS,NTP,RTSP,RTP,TCP,UDP,IGMP,RTCP, ICMP,DHCP,ARP,SOCKS,SSH,LLDP,MQTT v3.1.1System integrationApplication Programming Interface Open API for software integration,including VAPIX®and AXIS Camera Application Platform;specifications at AXIS Video Hosting System(AVHS)with One-Click Connection ONVIF®Profile G,ONVIF®Profile S and ONVIF®Profile T. Specification at Analytics IncludedAXIS Video Motion Detection,active tampering alarmSupportedSupport for AXIS Camera Application Platform enablinginstallation of third-party applications,see /acap Event triggers Analytics,edge storage events,external inputEvent actions File upload via FTP,HTTP HTTPS,SFTP,network share and email Notification via email,HTTP,HTTPS,TCPVideo recording to edge storage,pre-and post-alarm videobuffering,PTZ preset,guard tour,send video clip,send SNMPtrap,day/night vision mode,WDR mode,status LED indicator,output portData streaming Event dataBuilt-ininstallation aidsPixel counterGeneralCasing IP66-and NEMA4X-rated,IK10impact-resistant polymerenclosureColor:White NCS S1002-BSustainability PVC-freePCB is bromine-freeMemory512MB RAM,256MB FlashPower8-28V DC or Power over Ethernet(PoE)IEEE802.3af Class2,max5.0W,typical3.6WConnectors RJ4510BASE-T/100BASE-TX PoETerminal block for one input and one output(12V DC output,max.load15mA)DC input,terminal blockStorage Support for microSD/microSDHC/microSDXC cardSD card encryptionSupport for recording to network-attached storage(NAS)For SD card and NAS recommendations see Operatingconditions-20°C to50°C(-4°F to122°F)Humidity10–100%RH(condensing)Storageconditions-20°C to50°C(-4°F to122°F)Humidity5-95%RH(non-condensing)Approvals EMCEN55022Class A,EN61000-6-1,EN61000-3-2,EN61000-3-3,EN61000-6-2,EN55024,EN50121-4,FCC Part15Subpart B Class A,ICES-003Class A,VCCI Class A,RCM AS/NZS CISPR22Class A,KCC KN22Class A,KN24SafetyIEC/EN/UL60950-22IS13252EnvironmentEN50581,IEC60068-2-1,IEC60068-2-2,IEC60068-2-14,IEC60068-2-30,IEC60068-2-78,IEC/EN60529IP66,NEMA250Type4X,IEC/EN62262IK10,IEC60721-4-4Class4M4NetworkNIST SP500-267Dimensions222x137x448mm(83/4x53/8x175/8in)including wallmountWeight 1.6kg(3.5lb)including wall mountIncludedaccessoriesAXIS T94Q01A Wall Mount,Resistorx T20tool,Connector kit,Installation Guide,Windows®decoder1-user license OptionalaccessoriesAXIS T94R01P Conduit Back Box,AXIS T98A16-VE SurveillanceCabinet Series,AXIS T91A47Pole Mount,AXIS T90B Illuminators VideomanagementsoftwareAXIS Camera Companion,AXIS Camera Station,Videomanagement software from Axis’Application DevelopmentPartners available at /vmsLanguages English,German,French,Spanish,Italian,Russian,SimplifiedChinese,Japanese,Korean,Portuguese,Traditional Chinese Warranty Axis3-year warranty and AXIS Extended Warranty option,see/warrantya.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.(),and cryptographic software written by Eric Young(*****************).Environmental responsibility:/environmental-responsibility©2015-2021Axis Communications AB.AXIS COMMUNICATIONS,AXIS,ARTPEC and VAPIX are registered trademarks ofAxis AB in various jurisdictions.All other trademarks are the property of their respective owners.We reserve the right tointroduce modifications without notice.T10047021/EN/M15.3/2101。
ZX11高纯度非发光传感器安装与维护指南说明书
Cautions for proper and safeoperation. To use this productsafely, please read this instructionmanual carefully. Incorrect operationmay cause malfunction, damageor accident. The cautions andwarnings in the document areindicated by the following:WARNING: I ndicates that incorrect use may result inservice injury or loss of life.CAUTION: I ndicates that incorrect use may result inservice injury or property damage.WARNING:1. Do not apply pressure greater than the maximumallowable pressure. This may cause damage or rupturethe pressure element, resulting in injury or damage to the surroundings.2. Do not use this product to measure fluid which causesgas/liquid contact area to corrode. This may cause dam-age or rupture the pressure element, resulting in injury or damage to the surroundings.3. Do not apply excessive weight, vibration or shock. Thismay cause damage or rupture the pressure element, result-ing in injury or damage to the surroundings.4. Use of a non-designated power source may cause fires orelectric shocks.5. Use this device within the operating temperature range.Using the instrument outside of the recommended operat-ing temperature range may cause malfunction or damage and result in injury or damage to the surroundings.6. Perform wire connection according to the wire connectionfaceplate or the wire connection instructions within theinstruction manual. Incorrect wiring may cause injury or fire.7. Use explosion-proof product when required or explosivegas exists; this is due to the potential of ignition or explosion.8. Use instruments that have been properly cleaned and arefree of oil when the process media is oxygen. Standard(uncleaned) product may contain oil; contact with oxygen can result inignition and/or explosive reactions.9. Perform installation according to the instruction manual.10. D o not alter this product in any manner or form. In addi-tion, do not disassemble this product. Contact Ashcroft for repairs.11. S ince this product is a precision measuring instrument, itis advised that the product be removed from all sourcesof noise. Remove noise from the power source by usingnoise filter, etc.Table of contents:1. INTRODUCTION (2)2. ATTENTION (2)3. GENERAL DESCRIPTION (2)4. OUTLINE DRAWINGS (Representative example) (2)5. PRECAUTIONS FOR USE5-1. Transportation precautions (3)5-2. Unpacking precautions (3)5-3. Mounting precautions (3)5-4. Storage precautions (4)6. WIRING6-1. Examples of wire connection & external connection ..4 6-2. Load resistance (4)6-3. Specifications of the cable with M12 connector(optional) (5)7. PRINCIPLE OF OPERATION (5)8. ZERO AND SPAN CALIBRATION (5)9. MAINTENANCE AND OPERATION9-1. Maintenance (5)9-2. Adjustment (6)10. WARRANTY (7)11. OTHERS (7)4. O UTLINE DRAWINGS: ZX11 Male Flow-ThruOUTLINE DRAWINGS: ZX11 Female Swivel[20]0.18[4.5]OUTLINE DRAWINGS: ZX11 Male FixedOUTLINE DRAWINGS: ZX11 Male Swivel5. P RECAUTIONS FOR USE5.1 Transportation PrecautionsCAUTION:T his is a precision measuring instrument. Do not drop or impact when transporting asshock may cause damage and render the instrument inoperable.5.2 Unpacking Precautions• Check packaging appearance prior to unpacking.• C arefully handle and do not drop unit carton.CAUTION: • O pen instrument’s sealed bag in a cleanenvironment. Do not expose PressureTransmitter’s gas contact parts to moisture, dust, etc.• U pon unpacking, inspect unit to verify that the model type and physical appearance are correct and free from damage.• C ontact distributor or Ashcroft if any abnormality has been identified with the product.5.3 Installation Precautions (1) Z X11 pressure transmitter is equipped with a union connection that is compatible with a VCR fitting. For installation, make sure to use hexagonal flats to tighten fitting. Do apply force to the unit enclosure when attached to the pressure line.(2) This product has protection class IP67 (connector mating state/JIS C 0920).For longer-term operation, select a location that is notexposed to direct sunlight, condensation, dust, oil or water. In addition, please pay particular attention to the following during installation .• Do not drop or impact unit as shock mayrender unit inoperable.• Do not install product in an environment exposed to vibration, impact, direct sunlight or dust.• Use product in ambient temperaturesbetween 0 to 140 °F (0 to 60 °C)• Allow for space around the instrument formaintenance and adjustment.• Do not touch or breathe on the gas contact parts, while taking care not to damage theIndicates that incorrect use may result in service injury or loss of life.seat surface. CAUTION: • Do not apply excessive force to theenclosure during installation.[25]Ø 0.79[20]0.18[4.5][25][20]0.18[4.5]WARNING: • Take care not to block the air inlet on thetop of the instrument (Refer to “5. Outline drawings”). Unit will not provide prescribed performance if the air inlet is obstructed/blocked.• Do not apply excessive force or excessive bending to the cable once the connector is attached to the product and the matingconnector.• Snoop test of the sensor part should be avoided as this may cause an insulation resistance defect.• Prior to commencing operation, it is recommended to purge the unit with sufficient inert gas. This will remove any atmospheric component, particles, and/orforeign matter within the pipe5.4 Storage Precautions• T o avoid failure or damage, do not store product under the following conditions:• Do not expose to water• Susceptible to adverse effects due to air pressure, temperature, humidity, ventilation,sunlight, particles, salt or sulfur in the air CAUTION: • D o not expose to inclination, vibration orshock (including during transportation)• D o not expose to chemicals (chemicals’ storage area) or gas• Do not expose to direct sunlight or high temperature• D eformation and discoloration of resin parts may occur when product is stored in asealed bag under high temperature and high humidity environments.6. WIRING6.1 Wiring schematic of mating connectorWire connection and external connection should be carried out as follows.Insert the cable with M12 connector (optional) while aligning to the connector groove on the instrument. Hand-tighten until the nut does not move. [Tightening torque: 0.4 to 0.5N •m]6.2 Load ResistanceRefer to the following chart for relationship between load resistance and power supply voltage.[Current output: 4 to 20 mA DC (2-wire system)When connecting equipment that can generate surge from the same power supply, it is recommended that a voltage-depen-dent resistor (varistor) be connected to the pressure transmitter for protection. In addition, take the following precautions when wiring: • D o not pull or bend the cable with excessive force.• W hen mounting, check the specification rat-ing of the product and determine the power supply rating to be used. Once the productload resistance has been verified, use thePower Supply & Load ResistancePower Supply (Vdc)R Lmax R LminL o a d R e s i s t a n c e Ω100090080070060050040030020010008 10 12 14 16 18 20 22 24 26 28 30Maximum load resistanceMinimum load resistanceR L max E (V)-10(V) (Ω)0.02(A)R Lmin E (V)-26.4(V), R Lmin ≥o(Ω)0.02(A)Block diagram (4 to 20 mA DC/2-wire system)8. Zero and Span Calibration 1) P rior to powering the unit, double-check to make sure all wires have been properly connected. Verify that voltage and amperage ratings of the power supply and internal resistance of the external adaptation equipment are within the rated range of the instrument’s load resistance. Lastly, re-confirm that the pressure transmitter has been installed within an operating environment that complies with the explosion-proof specification.(2) Z ero adjustment can be performed once the unit has been powered for a 15-minute warm-up period. Zero adjustment can be performed by removing the rubber plug located at the top of the enclosure. Refer to “9-2. Adjustment” (below) to adjust properly.Observe the following precautions while operating:• D o not apply any pressure above that refer-enced on the product’s label.• D o not adjust wiring or insert/remove the connector while the device is powered, asthis may damage the device and/or causean electric shock. All wiring should be con-nected in accordance to the product wiringdiagrams.• I f used with corrosive gas, it is highlyrecommended that the pressure transmitter be fully purged with nitrogen gas prior to being removed for maintenance or other servicing. Leaving corrosive gas within a device will accelerate corrosion by forming strong acid or alkaline substance generated internally by moisture or oxygen within the atmosphere.9. Maintenance and Adjustment9.1 MaintenaceRoutine inspection should be conducted at least once every 6 months with device recalibration or zero adjustment being performed as necessary. Product should only be inspected by properly trained personnel.CAUTION:WARNING:connected device’s internal resistance with-in its rated range.CAUTION: • W hen soldering, take care that the solderingiron does not touch the sheath of the caseor cable.• P roduct protection class IP67 may beimpaired if the tightening nut for the cable to the M12 connector (optional) proves insuffi-cient. Be sure to tighten securely to counter possible vibration; tightening torque: 3.54 to 4.43 in. lb.Do not not perform any wiring procedures when powering the unit.6.3 S pecifications of the cable with M-12 connector(optional)If using a connector that has not been supplied by Ashcroft, please make sure your connector meets the following specifications.The cable is comprised of a 4-wire systemCAUTION: (white, black, blue, brown), however, thewhite and black wires are not used.7. Principle of OperationThe transmitter’s sensing diaphragm converts pressure to an electrical signal by use of strain gages. The circuit is a full-bridge system where the strain gages are positioned on all four bridge sides and detect the amount of strain. An electrical signal, in proportion to the strain amount, is then amplified to a specific value by the electrical circuit and transmitted as direct current output.(1) Z inc die-casting (nickel-plated)(2) TPU (Green)(3) PUR)1)S tainless (2) TPU (Black)(3) PVC)2 m or 5 m 2 m or 5m 0.34 mm (22AWG)or higher in a mating state.• T he rubber plug is equipped with a simpletethering function, however if it is pulled CAUTION:strongly, the function is impaired. Please becareful not to pull too much more than nec-essary [<17 in. lb.].The “Z” on the rubber plug indicates the position of the potentiometer for Zero adjustment, and the “S” indicates the position of the potentiometer for Span adjustment.a. A djust the zero point output in the same way as [(1) Zero adjustment].b. A ccurately apply pressure upper limit in the pressure range, and then adjust the output to 20 mA DC in span adjustment potentiometer.c. R epeat several times alternating Step a and b to make the span adjustment. • D o not change zero adjustment while rotat-ing span adjustment potentiometer.• A void putting an excessive load, >44 in. lb.,10 sec., on the zero/span adjustment poten-tiometers as this may result in damage.• D o not apply pressure above the pressure range indicated on the device label.After the adjustment, please be sure to attach the rubber plug by referring to the figure below.The “Z” on the rubber plug indicates the position of the poten-tiometer for zero adjustment, and the “S” indicates the position of the potentiometer for span adjustment.• E nsure rubber plug has been returned to its original position to retain product pro-tection class integrity. Protection class maybe impaired if the rubber plug is not firmly affixed.10. WARRANTYIf the delivered products within the warranty period (within one year from the delivered date) are determined to be non-con-forming products according to “Defects due to the design or manufacturing”, they are repaired or replaced with conforming products free of charge.However, note that the following cases are excluded.(1)W here the delivered products are disassembled, altered or where their parts are replaced or new function is add by the customer or any third partyCAUTION:CAUTION:(2) W here directions described in the instruction manual or cat-alog are not observed.(3) W here the non-conformance is caused by deterioration due to use, natural disaster, fire or other force majeure events (4) T he secondary damage caused by non-conformance of the products including the above.Returned units are subject to evaluation by Ashcroft prior to determining warranty. 11. OTHERSThis instruction manual is not intended to cover all equipment and/or installation and maintenance details. Please contact Ashcroft if additional detail is sought, or in the event that the instrument does not adequately serve your company’s intentions.Additionally, this instruction manual may be changed, at any time, without prior notice for the purposes of version upgrades, revisions etc.Thank you for your understanding and cooperation.。
韩国铂金科技(SONEL)TDR-410时域反射仪数据参考页说明书
CABLE FAULT LOCATORThe TDR-410 is a Time-Domain-Reflectometer (TDR) that detects breaks, short circuits, moisture damage, and changes in impedance of cables. The backlit display gives automatic indication of the type of fault and the distance to the fault.Identify damage and faults of cables and conductors: »Power cables »Copper telecom cables »Coaxial cables »Wiring infrastructuresKEY FEATURES:»Automatic or manual operation modes »Scan automatically or manually trigger »Single measurements triggered manually »Continuous scanning operation »Automatic fault location (AFL) »Range and sensitivity can be set manually or automatically »Maximum length of cable up to 4000 m / 14000 ft (2.5 miles) »“Dead zone” measurement limited to 0.5 m / 1.64 ft »Adjustable impedance matching »Propagation coeffi cient adjustment 1% to 99% »2.5” backlit LCD screen »Waterproof, IP 54 / NEMA 3 rugged case construction »Small size and weight »Low power usage – up to 30 hours of operation on 4 AA batteries SONEL TDR-410Cable fault locatorOpen conductor Shorted conductor Tap Water ingress Splitter Split / resplitWet splice / waterSpliceRanges in Feet20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000 Ranges in Meters7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km Range SelectionManual or Auto Accuracy1% of selected range ResolutionApprox 1% of range Minimum cable length4 m / 14 ft.SensitivityMin 3 pixel return at 4km / 14000 ft. on 0.6 mm diameter, PE, TP Velocity FactorAdjustable from 1% to 99%Output Pulse5 volts peak to peak into open circuit, width 3 ns to 3 µs, Automatic with range Output ImpedanceSelectable 25, 50, 75 & 100 ohms Scan Rate2 scans per second or scan held, pre-set for each range scale Tone Generator810 – 1100Hz Battery Life30 hours continuous scanning Power Supply4 x 1.5 AA Alkaline cells, low battery indicator Power Down Time1 - 5 minutes selectable, or disabled Backlight Display128 x 64 pixel, 2.5” LCD Voltage Protection250 volts AC Operating Temp-10º to 50ºC / 14 º to 122 ºF Storage Temp-20º +70° C / -4 º to 158 ºF Dimensions165 x 90 x 37 mm / 6.5 x 3.5 x 1.5 ins Weight350 g / 12 oz SafetyIEC 61010-1, EN 60950EMCBS/EN 61326-1Case/Enclosure Rating IP 54 / NEMA 3, Water/Dust Proof SPECIFICATIONSEACH TDR-410 TIME-DOMAIN REFLECTOMETER IS SUPPLIED WITH:»2 ft /0.6 m double-wire test lead »2 crocodile clips; red, black »Cover M-2 »4 x 1.5V AA alkaline batteries。
OMEGA FLCN-110 单相传感器控制器说明书
2.8 x 4.7 x 3⁄4" NPT
Accessory
Model No. Price Description
FW-310
$20 Reference Book: Electronics Demystified
B-105
)UHHSKRQH _ ,QWHUQDWLRQDO _ )D[ _ 6DOHV#RPHJDFRXN
SPECIFICATIONS
Voltage Input: Selectable, 120 or 240 Vac, 50 to 60 Hz. Max Consumption: 5 watts Relay Output: Isolated and sealed single pole double throw (SPDT) relay, Form C Switching Mode: Selectable, NO or NC states Max. Relay Switching Voltage: 120 Vdc or 240 Vac Max. Switched Current: 10 amps Time Delay: Adjustable from 0.15 to 60 seconds Max. Temp. Rating: 70°C (158°F)
Model No.
Price
Description
Mat’l
Size
FLCN-111
$185 Single sensor controller PP 2.8 x 4.7 x 3⁄4" NPT
FLCN-111-CE 215 Single sensor controller PP Comes with complete operator’s manual. Ordering Example: FLCN-111, single sensor controller, $185.
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
CH2Cl + NaCN NaOH/C2H5OH CH + H2O H2SO4/HgSO4
3. CH3CH2CH2C
4. CH2=C-CH=CH2+HBr(1mol) CH3 5. 6. 7. 8. 9. N 10. CH2CH3 + Cl2 NH2 + Br2 光照
H2O 红磷 BF3
CH3CH2COOH + Br2 O + (CH3CO)2O
2003.10
陕西,杨凌高新农业示范区
6.下列化合物中不被稀酸水解的是(
)
(1)
O O
(2)
O
OCH3
(3)
O O
(4)
O O
7.下列羰基化合物与饱和 NaHSO 3 反应最快的是( O
)
O (4) CH3-C-CH(CH3)2
(1) CH3 CCH3
(2) CH3CHO
(3)
)
CHO
8.下列化合物最容易发生水解的是(
O (1) CH3C-OC2H5 (2) CH3CONH2 (3) (CH3CO)2O
) 9.下列卤代烃在 SN1 反应中反应速度最快的是(
(1) CH3CH2CH2CH2Br (3) CH3 CH3 C Br CH3 CH3 (4) CH3 CH CH2 CH3 Br
O (4) CH3C-Cl
(2) CH3 CH CH2 Br
K2Cr 2O7/H+ CHO+CH3CH2CHO 稀碱
七、从指定原料合成指定的化合物(每小题 4 分,共 16 分)
1. 2.
NH2
Br O
NH2
CH-O-C-CH3 CH3
Br CH3 Br CH3
OH Br OH C2H5
3. 4.
八、推导结构(第 1,2 小题各 4 分,第 3 小题 6 分,共 14 分) 1.化合物 A,分子式为 C5H10O,A 与 2,4-二硝基苯肼反应生成黄色沉淀,但不还原斐林试剂, 也不与 I2/NaOH 反应,推测 A 的结构式。 2.化合物 A,分子式为 C4H9NO,A 与 NaOH 溶液煮沸放出一种有气味的气体,残余物经酸化 后得化合物 B,分子式 C4H8O2,B 用 LiAlH4 还原可得 C,分子式为 C4H10O,C 用浓硫酸处理得 D, D 带支链,D 的分子式为 C4H8。推测 A、B、C、D 的结构式。 3.化合物 A,分子式为 C7H12,A 催化加氢生成 B,B 的分子式为 C7H14,A 经臭氧化、还原水 解后得 C,C 的分子式为 C7H12O2,C 可被吐伦(Tollen)试剂氧化为 D,D 的分子式为 C7H12O3,D 可发生碘仿反应生成 E,E 的分子式为 C6H10O4,E 加热生成酸酐 F,F 的分子式为 C6H8O3。D 经 Zn-Hg/HCl 还原生成 3-甲基己酸。推测 A、B、C、D、E、F 的结构式。
(1) NH2 (2) NH2 (3) NH2 (4) NH2
OCH3
NO2
Cl
4.下列酚类化合物中,pka 值最大的是(
(1) OH (2) OH (3) OH
)
(4) OH
N(CH3)2
Cl
CH3
NO2
5.下列物质中不具有芳香性的是(
(1) N (2)
)
(3) (4) O
- 1 -
朱伟教授编
2. 3.
CH2Cl OH
CH3 COOH
Cl
CH=CHCl CH2OH
O 4. C2H5OH CH3CHO CH3CCH3
五、写出下列反应的主要产物(每小题 2 分,共 20 分)
-2-
西北农林科技大学生命科学学院 有机化学与物胶化教研室
1. Br 2. CH3 Br
5.
二、按要求写出下列化合物的结构式(每小题 2 分,共 12 分) 1.用纽曼(Newman)投影式表示 1,2-二溴乙烷的优势构象 2.E-3-甲基-2-溴-2-戊烯 3. (2S,3R)-2-甲基-3-氯-1-丁醇的费舍尔(Fischer)投影式 4.甲基-α-D-吡喃葡萄糖苷的哈沃斯(Harworth)式 5.顺-1-甲基-4-乙基环己烷的优势构象 6.N-端是甘氨酸,C-端是丙氨酸的二肽 三、单项选择题(每小题 1 分,共 12 分) 1.下列自由基中最稳定的是( ) . . (1) CH3 CH CH2 CH2 (2) CH3 CH CH CH3 CH3 CH3 . . (3) CH3 C CH2 CH3 (4) CH2 CH CH2 CH3 CH3 CH3 2.下列化合物中熔点最高的是( ) (1)CH3CONHCH2COOH (2)H2NCH2COOH (3)H2NCH2COOCH 3 (4)(CH3)2NCH2COOCH3 3.下列胺中碱性最强的是( )
- 3 -
10.维生素 A 的结构为:
OH , (3)三萜 (4)四萜 11.分子式为 C5H10 的三员环化合物,其可能的异构体数目为( ) (1)3 个 (2)4 个 (3)5 个 (4)6 个 12.与 D-葡萄糖互为 C4 差向异构体的是( ) (1)D-半乳糖 (2)D-甘露糖 (3)D-果糖 (4)D-核糖 四、简要回答下列问题(每小题 3 分,共 6 分) 1.某氨基酸能完全溶于 pH=7 的纯水中,所得氨基酸的溶液 pH=6,试问该氨基酸的等电点是 大于 6,小于 6,还是等于 6,简要说明原因。 2.在酸催化下, (-)-2-羟基丙酸与甲醇反应,生成(+)-2-羟基丙酸甲酯。试推测产物构型 变化情况,简要说明原因。 六、用化学方法鉴别下列化合物(每小题 3 分,共 12 分) 1.CH3(CH2)4CH3 CH3(CH2)3C≡CH CH3(CH2)3CH=CH2
西北农林科技大学生命科学学院 有机化学与物胶化教研室
生物类有机化学模拟试题十
一、命名下列化合物(每小题 1 分,共 8 分)
1. Br CH3 3. COOH OH O CH3 7. C N(CH3)2 8. N+ NClCH3 6. SH O C CH2 O C OC2H5 4. 2. CH3 CH3 CH CH CH = CH2 OH O CH=CH C CH3