z Inching mode ¾ Power the controller on. ¾ Keep pressing both of [UP] and [STOP] on the controller for 5S. ¾ LED flashes 3 times and turns off. Setting is ok. ¾ Repeat the action, it turns to normal mode. ¾ It can work continuously when pressing the [UP] or [DOWN] for more than 1.5 seconds.
Installation Notes
z Please observe the following provisions in accord with standard of effective power. z Do not use metal objects to touch or shade the receiver, avoid the interference of
144 single/group
DC24
Ͳ10 174(L) ̚ 127(W) +45 51(H)
Application
Model LKͲCP641 LKͲCP642 LKͲCP644
LKͲSCEͲD LKͲLCD LKͲTC LKͲL LKͲLͲS
6
4
2
4
4
6
4
2
4
4
6
4
2
4
4
LKͲL38A 1000N
Manual switch up Manual switch stop Manual switch down Manual switch GND
Symbol
FSO FOO FOC 24V FSI COM S+ SͲ 12V WRD T /H
Description
Fire signal output
Fire output NO Fire output NC DC24V output Fire signal input Sensor COM
and the ceiling is more than 1.5 m, between two receivers is more than 0.2 m. z The main power supply must be cut off before installing wiring. z In order to prevent electrostatic interference, must ensure that the receiver is
4
4
4
LKͲL38A 1500N
2
2
2
Dimension
Lቤተ መጻሕፍቲ ባይዱD/KEY
LED/KEY L1 / K1 L2 / K2 L3 / K3 L4 / K4 L5 / K5 L6 / K6 L7 / K7 L8 / K8
Color
Blue Green Red Yellow Blue Blue Blue Blue
LK-MR52X Wi-Fi Actuator Controller
LK-MR52X Wi-Fi Actuator Controller
LKͲCP64X CONTROL PANEL (6A)
Feature
z Used in window opener, curtain motor and door opener 24V DC motor control z Power indicator/reset, Open/Stop/Close & channel selection buttons z BuiltͲin DC24V/6A switching power supply z AC100VͲ240V international wide voltage input z Single Channel, dual Channel and 4 channel outputs z Cascade with LKͲFP3ˈLKͲCP6/CP7/CP8 control panel that achieves windows of
1. Check the connection of wires. 2. Check the receiver setting.
1. Make sure the right installation of
2 LED on the transmitter is off or weak. the battery.
z Changing direction ¾ Power the controller on. ¾ Keep pressing both of [UP] and [DOWN] on the controller for 5 seconds. ¾ LED flashes 3 times and turns off. ¾ Directions changed successfully.
zone control and group control z Can handle external input signal of Manual Switch, Remote Control, Timer
Smoke/Gas/ Rain /Temperature & Humidity Sensors z Output fire feedback signal to fire centre z Compatible with all Linkayl remote z Inching mode and continuedͲrun mode settable z With stroke memory function
receiving signals. z Transmit distance: 50 meters without obstacle, 20 meters through wall. z The installation distance between the receiver and ground, between the receiver
z Clearing All Codes ¾ Power the controller on. ¾ Keep pressing both of [STOP] and [DOWN] on the controller for 5 seconds. ¾ LED flashes 3 times and turns off. ¾ All the codes matching the channel will be deleted after this operation.
Wiring
Symbol
L N E V+ VͲ MX+ MXͲͲ MU MS MD MG
Description AC live wire AC null wire AC earth wire
DC24V positive DC24V negative DC24V motor positive DC24V motor negative
effectively grounded. z After the installation, ensure that the receiver and cable are not affected by tension.
Troubleshooting
No.
Symptom
Solution
1 LED flashes, receiver shut down.
Status
On / Off On / Off / Flash
On / Off On / Off On / Off On / Off On / Off On / Off
Function
AC power indicator, Reset Open Stop Close
Channel 1 Channel 2 Channel 3 Channel 4
Electrical Wiring Guide
Switches, remote transmitters and rain sensors
Operation Description
z Setting method of single channel receiver is as same as double channel receiver. z Before setting multi channel transmitter, please choose the right channel which
Ordering Code
Model
Power (W)
Control Method
Input Volt Output Volt Temp
(V)
(V)
(ć)
Size (mm)
LKͲCP641 LKͲCP642 LKͲCP644
144 1 way single 2 way
144 single/group AC100Ͳ240 4 way
you want to program. z Maximum running time of motor is 5 minutes. z UP/DOWN delay time of switch is 500ms.
z Matching Code ¾ Power the controller on. ¾ Keep pressing [STOP] on the controller for 5 seconds. ¾ Press [UP] on the remote within 15 seconds ¾ LED flashes 3 times and turns off. ¾ Codes are matched successfully.
2. Change the battery.
The transmitter and the receiver
1. Check the wiring of motor.
3
work well, the motor does not work. 2. Make sure the motor no failure.
z Clearing Single Code ¾ Power the controller on. ¾ Keep pressing [STOP] on the controller for 5 seconds. ¾ Press [DOWN] on the remote within 15 seconds ¾ LED flashes 3 times and turns offDŽ ¾ Code is cleared successfully.
motor will run continuously, press the up / down key more than 1.5 seconds, the motor will stop after running a very short moment z In the inching mode, press the up / down key less than 1.5 seconds, the motor will stop after running a very short moment, press the up / down key more than 1.5 seconds, the motor will run continuously z Only the manual buttons on the panel, manual switch, remote control and cascade signal have inching mode z Keep pressing both of UP and STOP button on the controler for 5 seconds, LEDs flash 3 times and turn off it’s inching mode for the controler, repeat the operation the controler turns to continuedͲrun mode
Slave control up Slave control down
DC12V+ Rain sensor down
T/H signal
Control Mode
z Controler has inching mode and continuedͲrun mode which is default z In the continuedͲrun mode, press the up / down key less than 1.5 seconds, the