Omega称重传感器

合集下载

OMEGA LCKD系列微型压力传感器指南说明书

OMEGA LCKD系列微型压力传感器指南说明书

e-mail:**************For latest product manuals:User’s GuideLCKD SERIESSubminiature CompressionLoad CellsShop online at1Each LCKD Series Load Cell incorporates a small printed circuit board into the load cell’s lead wire. DO NOT remove this board or cut the cable between the compensation board and load cell. Removal of this board voids the calibration and warranty of the load cell.GeneralThe OMEGA®LCKD Series subminiature compression load cells arecompression-only units that are highly cost-effective. To ensureexcellent long-term stability and reliability in severe environments, theLCKD Series utilize high quality strain gages, precision gagingtechniques and all stainless steel construction. These units have a loadbutton machined as an integral part of the basic load cell. The load cellis designed to operate by mounting on a flat surface. The LCKD mustrest on a flat surface the same diameter as the D1dimension for properoperation.Shunt CalibrationThe LCKD Series are highly accurate millivolt output type load cellswith shunt calibrator for quick calibration checks. Shunt calibrationallows the user to install and calibrate the instrument in the fieldwithout the use of a dead weight tester. A 59 kilohm resistor is shortedacross negative excitation and negative signal output at the factory,which produces a simulated millivolt signal out of the transducer. Theshunt calibration signal is equivalent to a simulated pressure of:Shunt Cal mV/VSimulated Load = x Full Scale LoadCalibration Factor mV/VExample: Model LCKDWhere:Calibration Factor - 2.0315 mV/VShunt Cal - 1.4962 mV/VSimulated Load = 1.4962x 50 = 36.852.0315To set up the transducer in the field, follow these steps:1. Connect transducer excitation terminals to dc power supply.2. Connect transducer signal output terminals to readout instrument(DVM, Analog meter, etc.)3. Turn power on.4. Null transducer signal output with zero adjust potentiometer on meter.5. Short a 59 kilohm resistor across negative excitation and negativesignal output.6. Adjust the span potentiometer until the readout instrument reads thesimulated load as computed above (or that percent of full scalepressure).7. Remove 59 kilohm resistor and repeat steps 4 to 6 if necessary.(Span and Zero adjust pots may interact).8. The meter is now calibrated.IMPORTANT:Every load cell comes with a calibration sheet stating its full scale output, and this manual. Please save both.Specifications:Signal Output:See calibration sheetLinearity and Hysteresis:±0.25% full scaleRepeatability:±0.1% full scaleCompensated Temperature Range:60 to 160°F (16 to 71°C)Operating Temperature Range:-65°to 225°F (-54 to 107°C)Temperature Effect:Zero 0.01% full scale/°F;Span 0.01% of reading/°F Bridge Resistance:350 ohm bonded foil gageExcitation Voltage: 5 Vdc, 7 Vdc max.Full Scale Deflection:0.001" to 0.003"Safe Overload:150%Construction:Stainless SteelElectrical: 5 ft. four conductor cableWeight:<0.5 oz.WIRING CODERED(+) EXCITATIONBLACK(–) EXCITATIONGREEN(–) OUTPUTWHITE (+) OUTPUT2M4087-0305It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, human applications.Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RET URNING ANY PRODUCT (S) T O OMEGA, PURCHASER MUST OBT AIN AN AUT HORIZED RET URN (AR) NUMBER FROM OMEGA’S CUST OMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). T he assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following informa-tion available BEFORE contacting OMEGA:1.Purchase Order number under which the product was PURCHASED,2.Model and serial number of the product under warranty, and3.Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS,consult OMEGA for cur-rent repair charges. Have the following information avail-able BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2.Model and serial number of the product, and3.Repair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. T his document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.Servicing North America:U.S.A.:One Omega Drive, Box 4047ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928FAX: (514) 856-6886e-mail:*************For immediate technical or application assistance:U.S.A. andSales Service: 1-800-826-6342 / 1-800-TC-OMEGA Canada:Customer Service: 1-800-622-2378 / 1-800-622-BEST Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN Mexico:En Espan ˜ol: (001) 203-359-7803e-mail:*****************FAX: (001) 203-359-7807**************.mxServicing Europe:Benelux:Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121FAX: +31 (0)20 6434643Toll Free in Benelux: 0800 0993344e-mail:*****************Czech Frystatska 184, 733 01 Karviná, Czech Republic Republic:Tel: +420 (0)59 6311899FAX: +420 (0)59 6311114Toll Free: 0800-1-66342e-mail:*****************France:11, rue Jacques Cartier, 78280 Guyancourt, France Tel: +33 (0)1 61 37 2900FAX: +33 (0)1 30 57 5427Toll Free in France: 0800 466 342e-mail:**************Germany/Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria:Tel: +49 (0)7056 9398-0FAX: +49 (0)7056 9398-29TollFreeinGermany************e-mail:*************United One Omega Drive, River Bend Technology Centre Kingdom:Northbank, Irlam, ManchesterISO 9002 Certified M44 5BD United KingdomTel: +44 (0)161 777 6611FAX: +44 (0)161 777 6622Toll Free in United Kingdom: 0800-488-488e-mail:**************.uk。

loadcells[详细讲解]

loadcells[详细讲解]

load cells广州南创蔡工load cells称重传感器实际上是一种将质量信号转变为可测量的电信号输出的装置。

用传感器茵先要考虑传感器所处的实际工作环境,这点对正确选用称重传感器至关重要,它关系到传感器能否正常工作以及它的安全和使用寿命,load cells乃至在整个衡器的可靠性和安全性。

在称重传感器主要技术指标的基本概念和评价方法上,新旧国标有质的差异。

Load cells分类:Load cells称重传感器按转换方法分为光电式Load cells、液压式Load cells、电磁力式Load cells、电容式Load cells、磁极变形式Load cells、振动式Load cells、陀螺仪式Load cells、电阻应变式Load cells等8类,以电阻应变式Load cells使用最广。

全球称重传感器总汇(load cells) :您还在为自己找不到load cells(称重传感器)所以品牌而烦恼吗?下面对各知名品牌load cells(称重传感器)进行了以下汇总:美国Load cells:AmCells Load cells Ametek AMTI Apollo Research Corp ATI Industrial AutomationArtech Industries IncLoad cells Cooper Instrument Systems Load cells DJ InstrumentsDytran Instrument Inc Load cells Futek Advanced Sensor Inc Load cells Geokon IncHardy Instruments Inc Load cells Helm Instrument Co Load cells GW Instruments IncKistler-Morse(KM) Kulite Semiconductor Load cells Load Cell CentralMagnetic Power Systems Inc Magtrol Inc Load cells Measurement Specialists IncMorehouse Instrument CoLoad cells Michigan Scientific CorporationOmega Engineering RDP Electronic Sensors Schneider Electric-Kavlico SensorsSensoe System Solutions Inc(ACSI) Load cells SensorData Technologies Inc Serena Industries IncSinger Instruments Control IncLoad cells Load cells Soltec CorporationStrainsert StressTek IncSensor Developments IncLoad cells Load cells Toledo Integrated Systems Load cells Transcell Technology IncS.Himmelstein and Company JLM Instrument Arpege-Masterk AKO IncCardinal Scale Mfg.Co Load cells Celesco Transducer Checkline英国Load cells:Applied Measurements Ltd(AML) Control Transducers Ltd Halma Group-Thames Side-MaywoodRDP ElectronicS-Sensors Techni Measure Mecmesin Limited Industrial Measurements LtdDEM Machines Procter and Chester Measurements Ltd(PCM)Load cells LCM Systems Ltd德国Load cells:Burster Gmbh Honigmann Tension MeterLoad cells Lorenz Messtechnik GmbH ME-Messsysteme GmbHPeekel Instruments A.S.T Angewandte SYSTEM-TECHNIK法国Load cells:Scaime IncLoad cells Precia MolenLoad cells日本Load cells:Kyowa Sensor Systems Unipulse CorporationLoad cells Kistler Japan Load cells Sohgoh Keiso NTS Tokyo Sokki Kenkyujo韩国Load cells:C&M Robotics Hitrol Bongshin Loadcell意大利Load cells:Gefran ISILoad cells N.B.C.ElettronicaLoad cells Laumas Electtronica AEP Transducers DINI ArgeoLoad cells瑞典Load cells:Vetek ABLoad cells台湾Load cells:Arico(Gefran) Algol(NTS) EsenseLoad cellsLoad cells称重传感器的选择:Load cells称重传感器在选用时要考虑到很多因素,实际的使用当中我们主要从下列几个因素考虑。

Omega PX600 和 PX610 系列压力传感器说明书

Omega PX600 和 PX610 系列压力传感器说明书

PX602,PX603,PX605PX612,PX613,PX615Pressure Transducer M947/1009PX602,PX603,PX605PX612,PX613,PX615COMMON SPECIFICATIONS FOR ALL UNITSACCURACY:±0.4%FS (BFSL)(Linearity,Hysteresis and Repeatability)HYSTERESIS:±0.2%FS REPEATABILITY:±0.07%FS ZERO BALANCE:±1%FS STORAGE TEMPERATURE:–65°to 250°F(–53°to 121°C)OPERATING TEMPERATURE:–20°to 180°F(–28°to 82°C)COMPENSATED TEMPERATURE:–20°to 160°F(–28°to 71°C)THERMAL EFFECTS:(Zero)±0.04%FS/°F(Span)±0.04%FS/°FPROOF PRESSURE:15-2000PSI =200%FS;3000-5000PSI =150%FS 7500-20,000PSI =120%FSBURST PRESSURE:15-2000PSI =800%FS;3000-5000PSI =300%FS 7500-20,000PSI =150%FSCONSTRUCTION:Sealed units (All cables are vented.Sensor >300PSI is not)VIBRATION:<±0.1%FS effect for 0-2000Hz @20G’s in any axisSHOCK:<±0.05%FS effect 100G’s,20msec shock in any axisFATIGUE:100million cycles 20/80%FS with negligible performance lossCIRCUIT TO CASE INSULATION:100M ohms at 50VdcSENSOR TYPE:Chemical vapor deposited polysilicon strain gagesWETTED PARTS:17-4PH SS,300Series SS PRESSURE PORT:1⁄4-18NPT(15,000-20,000=9⁄16-18UNF Female Aminco)CASE:NEMA 4X,304SS RESPONSE TIME:5msPX602&PX612SERIES MILLIVOLT OUTPUTWIRING EXCITATION:10Vdc,(5-10Vdc limit @6mA max)(PX612)(PX602)OUTPUT:100mV ±1mV A Red +EXC SENSITIVITY:10mV/V B Green +OUTPUT OUTPUT IMPEDANCE:100ΩC Black –OUTPUT WEIGHT:2 oz (without cable)DWhite –EXCPX603& PX613 SERIES VOLTAGE OUTPUTWIRING EXCITATION:24Vdc, (10-36Vdc)(PX613)(PX603)OUTPUT:1-5Vdc (3 wire)A Red +EXC SUPPLY CURRENT:<3mA B Green OUTPUT OUTPUT IMPEDANCE:1000ΩDWhiteCOMMONWEIGHT:2 oz (without cable)PX605& PX615 SERIES CURRENT OUTPUTWIRING EXCITATION:24Vdc, (10-36Vdc)(PX615)(PX605)OUTPUT:4-20mA (2 wire)A Red +MAX. LOOP RESISTANCE:50 x (supply voltage –10)ΩCBlack–WEIGHT:2 oz (without cable)WARNING! Fluid hammer and surges can destroy any pressure transducer and must always be avoided. A pressure snubber should be installed to eliminate the damaging hammer effects. Fluid hammer occurs when a liquid flow is suddenly stopped, as with quick closing sole-noid valves. Surges occur when flow is suddenly begun, as when pump is turned on to full power or a valve is quickly opened.Liquid surges are particularly damaging to pressure transducers if the pipe is originally empty. T o avoid damaging surges, fluid lines should remain full (if possible), pumps should be brought up topower slowly and valves opened slowly. To avoid damage from both fluid hammer and surges, a surge chamber should be installed anda pressure snubber should be installed on every transducer.Symptoms of fluid hammer and surge’s damaging effects:1.Pressure transducer exhibits an output at zero pressure (large zero offset). If zero offset is less than 10% FS, user can usually re-zero meter, install proper snubber and continue monitoring pressures.2. Pressure transducer output remains constant regardless of pressure.3. In severe cases, there will be no output.HANDLINGThis instrument is susceptible to damage when exposed to static elec-trical charges. T o avoid damage to the sensor observe the following:• Ground the transducer body before making any electrical c onnections.• When disconnecting, remove ground connection last.Note:If supplied, the braided shield in the cable is not connected tothe transducer’s body and is not a suitable ground.MOUNTINGAlthough the units can withstand some vibration, it is always good practice to mount the sensor where there is minimum vibration. Use T eflon ®tape on NPT threads and install the wrench on hex flats. DO NOT tighten by using a pipe wrench on the housing.(T eflon is a registered trademark of E. I. Dupont de Nemours)CALIBRATIONAll models are tested to meet or exceed the published specifica-tions. The calibration and testing was performed using instrumenta-tion and standards that are traceable to the U.S. National Institute of Standards and T echnology (NIST). We further certify that our cali-bration systems complies with MIL-STD-45662.Each sensor comes calibrated and does not require recalibration.The zero and span pots are accessible through the top of the case.Loosen the four screws and separate the top carefully. The zero pot is marked with a white dot. Some models have the span pot on the side of the pull out board. Be careful of static charges when touching the board (span pot will be on the opposite side from the zero pot).WARRANTYOMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1)month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that our customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. Our Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification;misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear or are damaged by misuse are not warranted. T hese include contact points, fuses, and triacs.We are glad to offer suggestions on the use of our various products. Nevertheless, OMEGA warrants only that the parts manufactured by it will be as specified and free of defects.OMEGA MAKES NO OTHER WARRANTIES OR REPRESENT A TIONS OF ANY KIND WHA TSOEVER,EXPRESS OR IMPLIED, EXCEPT THA T OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBYD ISCLAIMED. LIMIT A TION OF LIABILITY : The remedies of buyer set forth herein are exclusive, and the total liabili-ty of OMEGA with respect to this order, whether based on contract, warranty, negligence, indem-nification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.Every precaution for accuracy has been taken in the preparation of this manual, however, OMEGA ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor assume liability for any damages that result from the use of the products in accordance with the information contained in the manual.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 1992 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing in this manual may be reproduced in any manner, either wholly or in part for any purpose whatsoever without written permission from OMEGA ENGINEERING, INC. 2M807Servicing USA and Canada: Call OMEGA Toll FreeOMEGA Engineering, Inc.One Omega Drive, Box 4047Stamford, CT 06907-0047 U.S.A.Headquarters: (203) 359-1660Sales: 1-800-826-6342 / 1800-TC-OMEGACustomer Service: 1-800-622-2378 / 1-800-622-BEST Engineering: 1-800-872-9436 / 1-800-USA-WHENFAX: (203) 359-7700 TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGAServicing Europe: United Kingdom Sales and Distribution centerOMEGA Technologies Ltd.P .O. Box 1, Broughton Astley, Leicestershire LE9 6XR, EnglandTelephone: (0455) 285520 FAX: (0455) 283912RETURN REQUESTS /INQUIRIESDirect all warranty and repair requests/inquiries to OMEGA’s Customer Service Department. Call toll free in the U.S. and Canada: 1-800-622-2378, Fax: 203-359-7811;International: 203-359-1660; Fax: 203-359-7807.BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, YOU MUST OBTAIN AN AUTHOR-IZED RETURN (AR)NUMBER FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.Please have the following information available BEFORE contacting OMEGA:1. P .O. number under which the product was purchased.2. Model and serial number of the product, and3. Repair instructions and/or specific problems you are having with the product.PX602, PX603, PX605PX612, PX613, PX615DIMENSIONSWIRINGPX602, PX612PX603, PX613PX605, PX615+––+POWER SUPPLY(–EXC)(+EXC)(+SIG)(–SIG)METERTRANSDUCER (PX602, PX612)RED WHITEBLACK GREEN DA BC++––POWER SUPPLY(COMMON)(+ EXC)(+ OUTPUT)METERTRANSDUCER (PX603, PX613)WHITE RED GREEN A DBPOWER SUPPLY。

螺栓压力传感器

螺栓压力传感器

螺栓压力传感器,带安装垫圈标准和公制型号压力0-10,000 N ~
0-500,000 N
OMEGA的LC900/LCM900系列螺栓受力传感器是设计用于测量螺栓夹紧力的压力称重传感器。

凭借出色的长期稳定性和全不锈钢结构,LC900/LCM900系列在恶劣的工业环境中的可靠性非常高。

这些装置设计为通过安装在2个安装垫圈(内含)之间的一个平面上来工作。

规格:
激励: 5 Vdc(最大值10V)
输出:标称2 mV/V
精度: ±3.5% FSO,综合线性度、滞后性及重复性
零点平衡: ±4% FSO
工作温度范围: -54 ~ 93°C (-65 ~ 200°F)
补偿温度范围: 16 ~ 71°C (60 ~ 160°F)
热效应:
零点: ±0.018% FSO/°C
量程:读数的±0.036%/°C
安全过载:容量的130%
极限过载:容量的150%
电桥电阻:标称120 Ω
结构:不锈钢
电气连接: 1.2 m (4')绝缘屏蔽电缆。

进口称重传感器

进口称重传感器

进口称重传感器广州南创谭工德国HBM称重传感器、压力、扭矩传感器及仪表、TEDEA-HUNTLEIGH称重传感器、瑞士METTLER TOLEDO称重传感器、西班牙Utilcell称重传感器、美国Celtron 称重传感器系列、美国Amcells称重传感器、美国RICE LAKE称重传感器、美国Nobel张力传感器、美国Sensortroncs(STS)称重传感器、美国KELI称重传感器、美国Transcell称重传感器及仪表系列、美国BLH过程测量控制系统、荷兰PHILIPS称重传感器、美国Interface称重传感器、ZEMIC称重传感器、日本NMB 称重传感器、日本A&D传感器、日本ASAHI隔离端子及数字面板表、压力传感器及仪表系列、美国MSI压力传感器、美国MEAS压力传感器及位移传感器、美国Motorola 压力传感器、韩国DACELL称重传感器、韩国CAS传感器、韩国Bongshin 称重传感器、韩国SETech传感器、美国Freescale汽车用传感器、美国AmCells A称重传感器、德国Sartorius称重传感器、德国FLINTEC传感器及仪表、德国NOVOtechnik位移传感器、意大利Laumas称重传感器及其仪表、英国Omega传感器、法国Master-K称重传感器及其显示器等世界著名公司的品牌产品。

产品广泛用于航空航天、化纤、机械、能源、交通建筑、钢铁、环保、制药、矿山、建筑机械、给水排水、石油天然气、化工冶金、水利电力、热力造纸、市政管理等领域中的电子秤、汽车衡、配料秤、全电子汽车衡、电子地上衡电子台秤、电子吊称、定量包装系统。

进口称重传感器光电池是利用光生伏特效应把光能直接转变成电能的器件,Mettler Toledo称重传感器在有光照情况下就是一个电源。

传感器由于它广泛应用于把太阳能直接变为电能,因此又称为太阳能电池。

进口称重传感器光电池的种类很多,NMB称重传感器以其半导体材料加以区别,如硒光电池、锗光电池、硅光电池、氧化亚铜光电池、砷化稼光电池、磷化稼光电池等。

OMEGA iTHX-SD 温湿度传感器说明书

OMEGA iTHX-SD 温湿度传感器说明书

ITHX-SD-5ITHP-W-6-CAL-3-HU ITHP-2-DB9ITHP-5-DB9UNIV-AC-100/240-5Temperature and Humidity Virtual Chart RecorderR-5U W eb Server U A larms by Email or Text Message U N o Special Software Required U R ecords Years of Data on Popular SD Cards U D ual Probe OptionThe OMEGA ®iTHX-SD transmitter let’s you monitor and recordTemperature, Relative Humidity and Dew Point over an Ethernet network or the Internet with no special software except a Web Browser.The iTHX-SD serves Active Web Pages to display real time readings, display charts of temperature, humidity, and dew point or log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic.The virtual chart viewed on the web page is a JAVA™ Applet that records a chart over the LAN or Internet in real time. With the iTHX-SD, there is no need to invest time and money learning a proprietary software program to log or chart the data.SD Flash Memory CardThe iTHX-SD comes completewith a removable 2 GB SD FlashMemory card that can store up toseven years of readings taken at ten second intervals.Records on SD Flash Cards The data is recorded on widely available SD (Secure Digital) flash cards. The format is a simple text file that is easily imported to spread sheets and other programs. It canbe read on a PC or MAC with a USB card reader. You can also download the data remotely over an Ethernetnetwork or the Internet.™®FCC-BAlarm RelaysThe iTHX-SD features two 1.5 Amp relays. With the easyWeb-based setup page, the two relays can be programmed for ancombination of temperature or humidity, and high or low set points. The relays canalso be programmed to remain latched and require a manual reset if a limit is exceeded.Battery BackupThe iTHX-SD comes with a universal 100 to 240 Vac power adapter. A standard 9 Volt Alkaline battery (also included) allows the device to log data for up to 2 days without external ac power. A failure on the Ethernet network will not interrupt data recording.Adjustable ChartsChart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity canbe charted across the full span (-40 to 124°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). When a second sensor is added, users can select a chart that records channel 1, channel 2 or the difference of the two channels.Award-Winning Technology The iTHX-SD is simple to install anduse, and features OMEGA’s award-winning iServer technology that requires no special software excepta Web Browser.The iTHX-SD connects to anEthernet Network with a standard RJ45 connector and sends data in standard TCP/IP packets. It is easily configured with a simple menu using a Web Browser and can be password protected.From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name such as “Cleanroom5” or “ServerRoom” in any Web Browser, and the iTHX-SD serves a Web Page with the current readings.View Temperature + Humidty with a Web BrowseriTHX-SD-5D shown smaller than actual size withSD card and DB9-Y cable for dual probe (included).Email AlarmsAll OMEGA iTHX-SD models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user or a distribution list anywhere in the world, including text messages to cell phones and PDA’s.Link to Web CAM orIP CameraThe Web page includes a link toa “Web Cam” or “IP camera” (not included). If you get a message about an alarm condition, you can quickly click on the link to view the actual scene over the Internet. Display and ChartTwo ChannelsThe iTHX-SD transmitters come complete with a temperature and humidity probe for measurement of a single location. With the addition of a second probe, the iTHX-SD transmitter can measure and display temperature, humidity and dew point in a second location up to ten feet away.The transmitter can display and chart absolute measurements in both locations, or a differential measurement between the two locations. The second probe requires no change to the basic iTHX-SD transmitter hardware,it can be added at the time of purchase or in the future. OMEGA offers a choice of industrialprobes in 2 and 5" lengths, anda wand style for ambient indoor applications. A simple DB-9 “Y” connector is available for adding asecond probe.Sensor and CalibrationIt is not necessary to takethe iTHX-SD out of servicefor routine calibration. The temperature/humidity sensorsare interchangeable and can be replaced for about the same cost as a typical calibration. OMEGA offers replacement sensors with optional 3-point NIST traceable calibration certificates.R-6View temperature and humidity over Ethernet or the Internet.Industrial Probe iTHP-5, iTHP-2:137 L or 51 L x 16 mm Dia(5 L or 2 L x 0.63" Dia)Housing Material: 316 SSCable with DB9 Connector:3 or 0.9 m L (10 or 3')Cable Operating Temperature:-40 to 125°C (-40 to 257°F)iServer SpecificationsINTERFACESEthernet: (RJ45)Fixed or auto-negotiating10/100BASE-T, Auto MDI/MDIXSupported Protocols:T CP, UDP, SNMP, SMTP,NTP, ARP, ICMP, DHCP, DNS,HTTP and TelnetSensor: Digital 4-wire, DB9LCD Display: 16 digits, 6 mm (0.23")SD Flash Memory Card:2GB card: 8 months of data storage at1 second recording intervals or 7 yearsat 10 second intervalsRelay Outputs:Two relays 1.5 A @ 30 VdcEmbedded Web Server:Serves Web pages containing real-timedata and live updated charts withindefinable time intervalsSoftware: OPC Server; macrofor datalogging in Excel program;compatible with Windows operatingsystemsPowerInput: 9 to 12 VdcSafety qualified AC power adapter:Nominal Output: *********Input: 100 to 240 Vac, 50/60Hz(included)Back-up Battery:9 Vdc, alkaline (included)ENVIRONMENTALOperating Temperature:iServer unit: 0 to 60°C (32 to 140°F)Battery: -18 to 55°C (0 to 131°F)ac Adapter: 0 to 40°C (32 to 104°F)Storage Temperature: -40 to 85°C(-40 to 185°F)PackagingMaterial: Steel metal case with wallmount bracketSensor SpecificationsRELATIVE HuMIDITY (RH)Accuracy/Range:10 to 90%: ±2%5 to 10% and 90 to 95%: ±3%0 to 5% and 95 to 100%: ±4%Non-linearity: ±3%Hysteresis: ±1%RHResponse Time: 8 seconds, tau 63%Repeatability: ±0.1%Resolution: 0.1%, 12 bitTEMPERATuRE (T)Accuracy/Range*Wand Probe: ±0.5°C (±1°F) for 5 to45°C (41 to 113°F); up to ±1°C(up to ±2°F) for 0 to 5°C and 45 to 60°C(32 to 41°F and 113 to 140°F)Industrial Probe: (see chart in manual)±0.5°C (±1°F) for 5 to 45°C (41 to 113°F);up to ±1.5°C (up to ±2.7°F) for -40 to5°C and 45 to 124°C(-40 to 41°F and 113 to 255°F)*Note: extended temperature range is forInd. probe only, the iServer’s operatingtemperature is 0 to 60°CResponse Time: 5 to 30 seconds,tau 63%Repeatability: ±0.1°CResolution: 0.1°C, 14-bitProbe SpecificationsWand Probe:198 L x 19 mm Dia (7.8 L x 0.75" Dia)Cable with DB9 Connector:152 mm L (6" L)Cable Operating Temperature:0 to 80°C (32 to 176°F)Readings through embedded Web serverTypical ApplicationsThe iTHX-SD is great formonitoring temperature + humidityin applications such as: cleanrooms, computer rooms, HVACsystems, pharmaceutical and foodprocessing and storage, hospitals,laboratories, semiconductor fabs,electronic assembly, warehousing,museums, manufacturing, green-houses, farm animal shelters,and many more.R-7Data logging spreadsheetOrdering Examples: iTHX-SD with LCD display, SD card, 2 relay alarm, battery back-up and wand probe. iTHP-W-6-CAL-3-HU , calibrated replacement probe with certificate.Replacement Probes with Calibration Certificate StandardAlarm relay configurationthrough embedded Web serverSensor configurationRecording SetupReadingsChart Web Link SetupOverview NetworkConfiguration Management Security Recording System Diagnostics Log OutiP-PCWiP-PCIiP-SCITHX-SD-2ITHP-W-6ITHX-SD-5-5DITHX-SD-5ITHP-W-6-CAL-3-HU ITHP-2-DB9ITHP-5-DB9UNIV-AC-100/240-5。

omega美国PX309_CH系列

omega美国PX309_CH系列

全不锈钢传感器PX319-100GVPX329-100GVPX309-100GV.电缆型。

微型扭锁式。

坚固耐用的通用传感器通用规格订购一个缓冲器保护您的压力传,图片为实际尺寸。

规格OMEGA 的PX309系列量程低于100 psi 的型号使用高精度硅传感器,该传感器受充油不锈钢膜片的保护。

100 psi 及以上量程装置使用以分子状固定在不锈钢膜片上的硅应变片。

长期稳定性(1年): ±0.25%(常规)常规寿命: 一千万次(常规)工作温度: -40 ~ 85°C (-40 ~ 185°F)耐受压力:全psia 及≤50 psig 量程:容量的3倍或20 psi ,以较大值为准 100 psig 量程: 容量的2倍破裂压力: 容量的500%或25 psi ,以较大值为准响应时间: <1 ms冲击: 50 g, 11 ms 半正弦波冲击 振动: ±20 g 保护等级: IP 65接液部件:全psia 及1 ~ 50 psig 量程为316不锈钢; 100 ~ 10,000 psig 量程为17-4 PH 不锈钢压力端口: 1⁄4-18 MNPT 电气连接:PX309: 1.5 m (5') 2芯、3芯或4芯电缆(分别为mA 、5V 及 mV 输出) PX319: 微型DIN 连接器 (含对接连接器)P X329: 扭锁式连接器,导气对接连接器单独销售(PT06V-10-6S) PX359: M12,4针连接器重量:PX309: 154 g (5.4 oz)PX319、PX329、PX359: 100 g (3.5 oz)100 mV 输出激励:0 ~ 50 psig 及全psia 量程:10 Vdc (比率式),(5 ~ 12 Vdc 范围内) 100 ~ 10,000 psig 量程:5 Vdc (ratiometric), (3 ~ 10 Vdc limits)输出: 0 ~ 100 mV ,例外情况2 psi = 40 mV ,1 psi = 20 mV精度: 25ºC 温度下为 ±0.25% FS BSL (包括线性度、滞后性及重复性)零点偏移: ±2% FSO ; 对1和2 psi 量程为±4%跨距设置: ±2% FSO ;对1和2 psi 量程为±4%补偿温度: 0 ~ 50°C (32 ~ 122°F )归零和跨距校正热效应(在补偿范围内):15 ~ 10,000 psi 量程: ±2% FSO 5 psi 量程: ±3% FSO 2 psi 量程: ±4% FSO 1 psi 量程: ±5% FSO5V 输出激励: 9 ~ 30 Vdc(反向极性和过压保护)输出: 0 ~ 5 Vdc 或 4 ~ 20 mA5 ~ 10,000 psi 的静态精度: 25ºC 温度下 为±0.25% FS BSL (包括线性度、滞后性及重复性)零点偏移: ±2% FSO; 对1和2 psi 量程为±4%跨距设置: ±2% FSO; 对1和2 psi 量程为±4% 补偿温度:>5 psi 量程: -20 ~ 85°C (-4 ~ 185°F) ≤5 psi 量程: 0 ~ 50°C (32 ~ 122°F)总误差范围: ±2% FSO ;包括线性度、滞后性、重复性、热滞后及热误差(例外情况:2 psi = ±3%,1 psi = ±4.5%)0-10,000 psi0-690 bar微型DIN式。

OMEGA FLCN-110 单相传感器控制器说明书

OMEGA FLCN-110 单相传感器控制器说明书

2.8 x 4.7 x 3⁄4" NPT
Accessory
Model No. Price Description
FW-310
$20 Reference Book: Electronics Demystified
B-105
)UHHSKRQH _ ,QWHUQDWLRQDO _ )D[ _ 6DOHV#RPHJDFRXN
SPECIFICATIONS
Voltage Input: Selectable, 120 or 240 Vac, 50 to 60 Hz. Max Consumption: 5 watts Relay Output: Isolated and sealed single pole double throw (SPDT) relay, Form C Switching Mode: Selectable, NO or NC states Max. Relay Switching Voltage: 120 Vdc or 240 Vac Max. Switched Current: 10 amps Time Delay: Adjustable from 0.15 to 60 seconds Max. Temp. Rating: 70°C (158°F)
Model No.
Price
Description
Mat’l
Size
FLCN-111
$185 Single sensor controller PP 2.8 x 4.7 x 3⁄4" NPT
FLCN-111-CE 215 Single sensor controller PP Comes with complete operator’s manual. Ordering Example: FLCN-111, single sensor controller, $185.

英国Omega称重传感器

英国Omega称重传感器

英国Omega称重传感器广州南创蔡工英国Omega称重传感器公司简介英国Omega称重传感器自1962年成立以来,已经成长从生产热电偶单一产品线建立在技术市场的全球领导者,提供超过10万个最先进的产品用于测量和控制温度,湿度,压力,应变,力,流量,液位,pH值和电导率。

英国Omega称重传感器还为客户提供一个完整的数据采集,电加热和定制设计的产品线。

在过去的三十年,英国Omega称重传感器的手册,曾担任世界各地的工程师提供有价值的参考工具。

质量检测仪器和出色的客户服务,一直是英国Omega称重传感器成功的基石。

英国Omega称重传感器(load cells)的首要任务是明确的。

英国Omega称重传感器的设施存在“协助”解决方案,您的需求。

英国Omega称重传感器持续增长英国Omega称重传感器公司总部设在康涅狄格州斯坦福德,在位于新泽西州的布里奇波特。

Omega®除了其在英国的子公司,也有在加拿大的网站,Omega工程有限公司,英国Omega称重传感器集团还包括纽波特电子(网站在纽波特,美国,德国,法国,荷兰和捷克共和国),OMEGADYNE(位于美国俄亥俄州哥伦布市附近)以及Omega万泽蒂(在波士顿,马萨诸塞州)。

英国Omega称重传感器的产品在多个国家设立了国外办事处及售后服务中心,并在中国设立了广州南创传感事业部,为英国Omega称重传感器提供最佳的服务与解决方案。

在过去的40年Omega®已经从出身卑微,成为在过程测量和控制领域的国际领先地位,提供超过10万件。

英国Omega称重传感器公司的基本理念是创造就业机会,使个人实现自己最大的潜能。

英国Omega称重传感器公司的5个创始原则是:•英国Omega称重传感器创意及管理方法之间保持平衡在一个快速增长的创业•英国Omega称重传感器市场的商品和服务在每一个具体的广谱纪律,同时力争成为在该领域的领导者•英国Omega称重传感器发展及维持一个独特的推销和宣传风格•英国Omega称重传感器鼓励经理们发展自己的风格•英国Omega称重传感器记住的营销理念,顾客就是上帝英国Omega称重传感器(load cells)的成功在于它的质量,卓越的客户服务和具有丰富经验的技术支持的承诺。

美国Omega校准入门手册

美国Omega校准入门手册

什么是校准?简言之,校准是对设备进行调整以使其达到厂商规格的过程。

校准有时候也可以定义为发布数据。

这些数据包括报告或校准证书,它们向最终用户保证产品符合规格并且还可能符合外部标准,例如国际标准化组织的标准。

例如,该组织的ISO 9001标准为行业设定了全球性规格。

公司遵守这些标准,以确保其产品和服务为供应商和客户所接受。

校准的第二个定义称为认证更恰当。

有设备需要校准的公司可能把该设备送到计量/校准实验室,在那里,技术娴熟的技师使用自身必须达到严格校准要求的测量/测试仪器,将设备调整到符合规格或者确认设备已经符合规格。

在工业过程中使用的全部或者一部分组件都可以校准。

例如,温度校准可能包括仅校准探头、仅校准仪器或者校准与仪器连接的探头(系统校准)。

一般而言,校准设备或校准器的精度至少要比被校准设备高四倍。

通常,设备有一个校准范围,技师在此范围内的不同数据点检查规格。

正如Mike Cable 在《校准:技师指南》中解释的那样,“校准范围定义为‘限值之间测量、接收或传送数量的区域,该区域通过声明范围下限值和上限值表示。

’ 限值由零位值和范围值确定。

零位值该范围的下限。

范围定义为范围上限值与范围下限值之间的代数差。

”在校准过程中进行的调整必须要在某些公差范围内。

这类公差表示相对设备规定精度的极小的、容许偏差。

以在企业内部进行、由第三方实验室进行或者由厂商进行。

再校准频率因设备类型而异。

例如,决定何时再校准一个流量计主要取决引言如果不校准,最先进的工业设备也不会有太大作用。

通过校准,对一台设备进行的调整可以确保它按预期工作,可以确保我们可以依靠该设备提供可预见的、达到质量标准的精确结果。

本白皮书由Omega Engineering 提供,它解释了什么是校准,为什么校准很重要,以及校准如何起作用。

其中对NIST可溯源性进行了定义和讨论,并且包括对基本校准的分步说明。

本文还讨论了企业内部校准与实验室校准,并介绍了主要校准设备类型。

PXM309_CH 美国OMEGA仪器简介

PXM309_CH 美国OMEGA仪器简介

B-3
PXM319-020G[*]
PXM359-020G[*]
DP25B-E, DP41B
35 bar
PXM309-035G[*]
PXM319-035G[*]
PXM359-035G[*]
DP25B-E, DP41B
70 bar
PXM309-070G[*]
PXM319-070G[*]
PXM359-070G[*]
PXM359-001A[*]
DP25B-E, DP41B
2 bar
PXM309-002A[*]
PXM319-002A[*]
PXM359-002A[*]
DP25B-E, DP41B
3.5 bar
PXM309-3.5A[*]
PXM319-3.5A[*]
PXM359-3.5A[*]
DP25B-E, DP41B
DP25B-E, DP41B
140 bar
PXM309-140G[*]
PXM319-140G[*]
PXM359-140G[*]
DP25B-E, DP41B
200 bar
PXM309-200G[*]
PXM319-200G[*]
PXM359-200G[*]
DP25B-E, DP41B
350 bar
PXM309-350G[*]
B
7 bar
PXM309-007A[*]
PXM319-007A[*]
PXM359-007A[*]
DP25B-E, DP41B
15 bar
PXM309-015A[*]
PXM319-015A[*]
PXM359-015A[*]
DP25B-E, DP41B

美国OMEGA高精度小型压缩称重传感器

美国OMEGA高精度小型压缩称重传感器

z
对接连接器 PT06F10-6S
配件 型号
F
I
说明
PT06F10-6S 用于LC411/LCM411系列称重传感器的对接连接器 CA-6PC24-3-015 用于LC411/LCM411系列称重传感器的带扭锁式连接器电缆组件
F-36
接线代码 针 连接 A + 输出 PTIH-10-6P B – 输出 或等同 – 输入 C&E D&F + 输入
绿 PTIH-10-6P白 黑 或等同 红
绿 白 黑 红
51 (2.00)
球半径
H1ቤተ መጻሕፍቲ ባይዱ
51 (2.00)
25 (1.0)
H
28.6 (1.125) 仅用于LC411/LCM411 (双)的2号连接器
球半径
LC411-20K,连接器型, 图片为实际尺寸。
球半径
H1
H1
球半径
25 (1.0)
H1
25 (1.0)
H
H
25 (1.0)
H
外形尺寸:mm (inch)
D
0.254 D (0.010) 接线代码 接线器 + 输出 – 输出 – 输入 + 输入
0.254 (0.010) 接线代码 接线器 + 输出 – 输出 – 输入 + 输入
51 (2.00)
K
G
I
6.4 (0.25) 6.4 (0.25) 28.6 (1.125) 6.4 (0.25) 仅用于LC411/LCM411 (双)的2号连接器 9.4 (0.37) 13 (0.50) 16 (0.63) 19 (0.75) 6.4 (0.25)
56 (2.188) 6-40 UNF-2 69 (2.719) 10-32 UNF-2 105 3个安装孔均匀地分布在直径为 UNF-2 (4.125) 5⁄16-24 “G”、“I”螺纹 x “K” 厚度的圆周上 底视图 124 (4.875) 7⁄16-20 UNF-2 164 (6.438) 5⁄8-18 UNF-2 191 (7.500) 3⁄4-16 UNF-2 216 (8.500) 7⁄8-14 UNF-2 56 (2.188) M4 x 0.7

Mettler-Toledo ACT350精密称重传感器快速指南说明书

Mettler-Toledo ACT350精密称重传感器快速指南说明书

Q u i c k G u i d e30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide2ACT350 Precision Quick GuideIntended UseYour weighing transmitter is used for weighing. Use the scale exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo, LLC will invalidate its warranty.It is essential for the buyer to closely observe the installation information, product and system manuals, operating instruc-tions and other documentation and specifications. MT’s warranty and any liability are expressly excluded for damages caused by non-compliance with the applicable manuals.DocumentationFor further details on system configuration and operation, refer to the documents provided on /ind-act350-downloadsSafety WarningsRead the Installation section on ACT350 Precision User Guide before operating or servicing this equipment, follow allinstructions carefully, and save all documentation for future reference.WARNINGSFOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG.WHEN THIS EQUIPMENT IS INCLUDED AS A COMPONENT PART OF A SYSTEM, THE RESULTING DESIGN MUST BE REVIEWED BY QUALIFIED PER-SONNEL WHO ARE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF ALL COMPONENTS IN THE SYSTEM AND THE POTENTIAL HAZARDS INVOLVED. FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS DETAILED IN THE USER MANUAL. INCORRECT OR SUBSTITUTE COMPONENTS AND/OR DEVIATION FROM THESE INSTRUCTIONS CAN IMPAIR THE SAFETY OF THE TRANSMITTER AND COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.BEFORE CONNECTING/DISCONNECTING ANY INTERNAL OR EXTERNAL ELECTRONIC COMPONENTS, LOAD CELLS, HARNESSES OR INTERCONNECT-ING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.DO NOT INSTALL, DISCONNECT OR PERFORM ANY SERVICE ON THIS EQUIPMENT BEFORE POWER HAS BEEN SWITCHED OFF AND THE AREA HAS BEEN SECURED AS NON-HAZARDOUS BY PERSONNEL AUTHORIZED TO DO SO BY THE RESPONSIBLE PERSON ON-SITE.THE ACT350 Precision IS NOT INTRINSICALLY SAFE! DO NOT USE IN HAZARDOUS AREAS CLASSIFIED AS DIVSION 1 AND DIVISION 2, ZONE 0, ZONE 20, ZONE 1, ZONE 2 OR ZONE 21 BECAUSE OF COMBUSTIBLE OR EXPLOSIVE ATMOSPHERES.ONLY 24VDC POWER SUPPLY IS AVAILABE TO CONNECT WEIGHT MODULES / SCALES TO ACT350 Precision. ALL OTHER WEIGHT MODULES REQUIRE AN EXTERNAL POWER SOURCE. CONFIRM VOLTAGE BEFORE USE!30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide 3Weight Display000000Displays weight information~Motion, weight is currently changing B/G Gross Mode KG/G/LBWeight Display UnitSCL Scales status: On okay, flashing indicates scale error PWR Power status: On okay, Off errorNW Automation Network status: On okay, flashing indicated network error DEV Device status: On okay, flashing contact service NW1Green: Link , Yellow: Active NW2Green: Link , Yellow: ActivePhysical DimensionsFront Panel and Display FeaturesUp/Down ArrowKeysUsed for data entryEnterEnter key /Zero scale/Enter Operator menuLeft Arrow Key Switch position/Return30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide4Bottom DIP SwitchSwitch 1Switch 2DescriptionOFFOFF Normal stateOn or OFFONMaster Reset of all data during transmitter power-up ON OFFNo functionACT350 Precision and Weigh Module/Scales Wire ConnectionCheck the Weigh Module or Scale manual to confirm the power supply voltage.It is recommended to connect ACT350 Precision with Weigh Module or Scale via RS232 or RS422 interface.In the case of using RS485 interface of Weigh Module, it connects RS485- to RX-/TX-, RS485+ to RX+/TX+ on the ACT350 Precision side.NOTICEThe TX and RX cross wiring between Weigh Module or Scale and ACT350 Precision should be done for correct connection. See below in the Table 1; Table 2.24VDC Power Source Weigh ModuleWhen the Weigh Module or Scale is powered by ACT350 Precision with 24VDCThe Weigh Modules such as WKC (24VDC), PBK-9_APW / PFK-9_APW and SLF6 can be powered by ACT350 Precision directly.ACT350 Precision Pin Assignment Weigh Module SignalAPW products examplesPin No.Signal RS232RS422RS485*PBK-9; PFK-9; SLF-6; WKC Cable colors** 1+24V VDC VDC VDC White2GND GND GND GNDBrown3RX-TX-RS485-Purple4RX+TX+RS485+Orange5TX-RX-RS485-Violet6TX+RX+RS485+Black7RxD TxDYellow8TxD RxDPink9GND GND +ShieldShield ShieldRed (RS232)Green (RS422)Table 1: Pin Assignment and signals connection wiring scheme with 24VDC Power Supply.When the Weigh Module or Scale is powered externally with 12VDC.* Some manuals also use A-(or D-) and B+(or D+) to refer to RS485- and RS485+ respectively.** Cable color of the METTLER TOLEDO standard cables.ATTENTIONThe Weigh Modules or Scales powered by 12VDC should be supplied using external power source.30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide530499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide6Wiring connection examples for APW productsAPW Weigh ModuleType Cable type / Power SupplyACT350 PrecisionWXSCable No: 11141979 only RS232Power Supply: powered externallyWMCWMSCable No: according to data sheet RS232/RS422Power Supply: 24 VDC powered by ACT350 PrecisionPBK9/PFK9Cable No: according to data sheet RS232/RS422Power Supply: 24 VDC powered by ACT350 Precision SLF6WKCTable 3: APW products wiring connection examples.NOTICEPlease refer to the individual Weigh Module or Scale connection installation guide for correct wiring instruction.Order Item No:30476263 (PROFINET)30476264 (EtherNet/IP)Common Errors Shown on DisplayOvercapacityWeight overload. The weight display shows blank:Undercapacity Weight underload. The weight display shows blank: Array PLC ConnectivityAll actual Device Description Files (GSDML / AOP) and PLC Sample Code files are available to be downloaded at:/ind-act350-downloads30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide730499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide8Keypad Operator Menu StructureThe operator setup functionality via keypad is limited. Full configuration is possible via Webserver.Enter operator menu: Long Press ENTER . Use UP and DOWN keys to switch between menu icons. Use ENTER key to enter the next level menu and LEFT key to return to previous rmationModelACT350 Precision Transmitter SN ############S/W Version #.##.#####.##PLCFieldbus #.#.##.#Station Name IP Address###.###.###.###MAC Address##:##:##:##:##:##/ind-act350-downloadsSet Comparators Limit 1..5Input value with keypadTest & Adjustment Test Mode – External or Internal Weight – Input test weight value AdjustmentMode – External or Internal Step Control – On or OffWeight – Input calibration weight valueDisplay Error Messages List of latest error messagesLanguage SelectSelect language for HMI dis-playInput-English, Chinese30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide 9Setup Capacity & Incr.Input scale unit Input scales capacityInput Scale readabilityFilterCut-off Frequency – Input frequency Weighing mode Environment PLCProtocol - SAIFormat – 1 block format or 2 block format Byte order – Automatic, standard, Byte & Word Swap Ethernet/IP- MAC Address- Input DHCP - Disable, Enable - Input IP Address - Input Subnet Mask - Input Gate Way Profinet- Device Name - MAC Address - Input IP Address - Input Subnet Mask - Input Gate WayConnection TypeSerial: RS232, RS422, RS485- Input Baud rate: 150 … 115200- Input Bits: 8/None/1…- Handshake: None or XON/XOFF Webserver- Enable - Disable30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide10Error Messages Shown on DisplayCleaning the TransmitterUse a soft, clean cloth and mild glass cleaner. Do not spray cleaner directly onto transmitter. Do not use industrial solvents such as ac-etone.Disposal of Transmitter / WEEE InformationIn conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment Array (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU,per their specific requirements.Please dispose of this product in accordance with local regulations at the collecting point specified for electri-cal and electronic equipment.If you have any questions, please contact the responsible authority or the distributor from which you purchasedthis device.Should this device be passed on to other parties (for private or professional use), the content of this regulationmust also be related.Thank you for your contribution to environmental protection.30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide11Mettler-ToledoIm Langacher 448606 GreifenseeSwitzerlandPhone +41449442011Mettler-Toledo, LLC 30499331 Rev. 01, 09/2019To protect your METTLER TOLEDO product’s future:Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to these instructions and regular calibration and maintenance by our factory-trained service team ensure dependable and accurate operation, protecting your investment. Contact us about a METTLER TOLEDO service agreement tailored to your needs and budget.We invite you to register your product at /productregistration so we can contact you about enhancements, updates and important notifications concerning your /ACT350-Precision For more information。

使用万用表测量梁氏称重传感器的好坏

使用万用表测量梁氏称重传感器的好坏

使用万用表测量梁氏称重传感器的好坏称重传感器是一种常用的测力传感器,在工业、电力、电子、机械、船舶、化工、治金等领域中都有一定的应用。

梁氏称重传感器是称重传感器中的常用类型,具有测量精准、性能稳定等优点。

今天小编就来为大家具体介绍一下使用万用表测量梁氏称重传感器的好坏的方法吧,希望可以帮助到大家。

首先测量一下传感器输入端及输出端的电阻值,如果有此传感器的合格证的话,与合格证中标明的电阻做对比,如测得的数值超出标准范围,说明此传感器有问题。

目前常用的传感器阻值为两种:一种是低阻的,输入端为:400&Omega;&plusmn;20&Omega;,输出端为:350&Omega;&plusmn;5&Omega;;一种是高阻的,输入端为:800&Omega;&plusmn;20&Omega;,输出端为:700&Omega;&plusmn;5&Omega;;另外还可以测量一下传感器的输出信号,用数字万用表的MV 电压档,将传感器的输入端加上10VDC,然后测一下传感器的输出端电压,此电压值=10VX 传感器灵敏度X 传感器的受力值/传感器量程值;如果测量出的数值与计算出的数值相差较大,说明此传感器已损坏称重传感器本身输出的是毫伏信号4~20 毫安指的是电流信号经过放大的供电一般都是24V 交流的电源怎么用万用表判断称重传感器的输出与输入的四根线还有正负称重传感器输出电阻一般为350、480、700、1000 欧姆,输入端一般会进行一些温度、灵敏度的补偿,因此输入端电阻会比输出端高20~100 欧姆,因此用万用表量一下电阻值可以判断出来。

一般习惯输入和输出颜色为红黑绿白:红白绿兰等分标表。

高精度称重传感器

高精度称重传感器

高精度压力传感器和变送器供稿:OMEGA工业测量关键词:OMEGA,称重传感器,高精度OMEGA的PXM309系列工业压力传感器采用了我们的两种精密制造技术。

70 mb ~ 3.5 bar 的低压量程及高达20 bar的绝对压力量程使用由不锈钢膜片保护的精密微加工硅传感元件。

薄油膜可传送压力,并可确保传感器的高精度和稳定性。

量程为7 bar ~ 700 bar的中高表压量程型号使用精密的半导体应变片,应变片直接熔接至不锈钢膜片,形成可确保较长使用寿命和高稳定性的坚固结合体。

这些精密技术可在温度为25ºC时,使绝大多数量程型号具有0.25% FS BSL的高精度和1%的总误差范围。

PXM309系列传感器可提供绝对压力或表压(相对压力)型号,并密封至IP65环境保护等级。

规格:电源电压反向极性及过压保护输出为0 ~ 10 Vdc:10 mA时为15 ~ 30 Vdc4 to 20 mA: 9 to 30 Vdc静态精度为350 mb ~ 700 bar:25ºC时为±0.25% FS BSL(包括线性度、滞后性及重复性)长期稳定性(1年):满量程的±0.25%总误差范围170 mb:±4.5% 表压140 mb:±3% 表压350 mb:±1.5% 表压和绝对压力1 to 20 bar:±1% 绝对压力1 to 700:bar ±1% 表压注1:总误差率包括所有精度误差、热误差、量程与零点公差。

隔离(壳体到任何导线):1 M Ω at 25 Vdc压力循环:1 x 107次满量程循环压力过载70 mb ~ 3.5 bar表压:350 mb ~ 20 bar绝对压力:额定压力的3倍或1.38 bar,以较大值为准7 ~ 700 bar表压:额定压力的两倍破裂压力70 mb ~ 3.5 bar表压:额定压力的5倍或1.72 bar,以较大值为准350 mb ~ 20 bar绝对压力:额定压力的5倍或1.72 bar,以较大值为准7 ~ 700 bar表压:额定压力的5倍补偿温度70 ~ 350 mbar表压/绝对压力:0 ~ 50ºC (32 ~ 122ºF)1 ~ 700 bar表压:-20 ~ 85ºC(-4 ~ 185ºF)1 ~ 20 bar绝对压力:-20 ~ 85ºC(-4 ~ 185ºF)工作温度:-40 ~ 85ºC(-40 ~ 185ºF)响应时间:1 ms带宽:DC ~ 1 kHz(类型)压力连接件:G ¼外螺纹接液部件70 mb ~ 3.5 bar表压:316不锈钢350 mb ~ 20 bar绝对压力:316不锈钢7 ~ 700 bar表压:17-4PH不锈钢遵循CE的规定:EC55022、EC55011 辐射类A&BIEC:61000-2,-3,-4,-5,-6,&-9冲击:50 g 11 mSec半正弦波冲击振动:± 20 g电气连接PXM309:1.5 m (5') 2 芯或3 芯电缆,输出分别为mA 或10VPXM319:微型DIN连接器,内含对接连接器PXM359:M12 4针连接器遵循ROHS规定:是重量:典型150 g,取决于配置。

OMEGA流动感应器用户指南说明书

OMEGA流动感应器用户指南说明书

e-mail:**************For latest product manuals: /en-us/pdf-manualsShop online at User’s Guide***********************Servicing North America:U.S.A. Omega Engineering, Inc.Headquarters:800 Connecticut Ave. Suite 5N01, Norwalk, CT 06854Toll-Free: 1-800-826-6342 (USA & Canada only)Customer Service: 1-800-622-2378 (USA & Canada only)Engineering Service: 1-800-872-9436 (USA & Canada only)Tel: (203) 359-1660 Fax: (203) 359-7700e-mail:**************The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.GENERAL DESCRIPTION1.1Working PrincipleWhen liquid flows through the casing of sensor,the impulse of fluid will provide the blade with a rotation moment as there is an angle between the blade of impeller and the flow direction.The blade will rotate as the friction moment and the fluid resistance are overcome and it will reach a stable speed when the moments are at balance.Under certain conditions,the rotation speed of blade will be in direct proportion to the flow velocity.Due to the magnetic conductivity of blade,when located in the magnetic field generated by signal detector(made of permanent magnet steel and coils),the rotating blade will cut the magnetic lines and periodically change the flux through the coil,thereby inducing electrical impulse signals at both ends of the coil.The induced signals,after amplified and rectified by amplifier,will form a continuous rectangular impulse wave with certain amplitude which may be remotely transmitted to display instrument indicating the instant flow and the cumulative flow of fluid.Within a certain range of flow,the impulse frequency f is in direct proportion to the instant flow of fluid flowing through the sensor.FEATURES1.The sensor is of hard alloy bearing thrust type,which may guarantee the precision and improve the wear resistance performance as well.2.Simple and firm structure,easy for installation and dismantling.3.Wide range of measuring with very low lower flow velocity limit.4.Small loss of pressure,fine repeat ability and high precision.5.High resistance to electromagnetic interference and vibration. SPECIFICATIONSMATERIALS OF CONSTRUCTION:Body:304OR316Stainless SteelRotor:CD4MCU Stainless SteelRotor Support and Bearing:316Stainless SteelRotor Shaft:Tungsten CarbideOPERATING LIMITATIONS:Tempe r ature:-20°C to+120°C High temperatures will damage the magnetic pick-up, while lower temperatures will limit the rotation of the rotor.Pressure:Maximum pressure ratings as follows:913.5psi─all NPT meters up to1"362.5psi─1-1/4”,1-1/2”,2"male NPT1232psi ─2-1/2”,3”,4”male NPTAccuracy:±0.5%of reading Repeatability:±0.1%Calibration:Water (CNAS Traceable Calibration)Corrosion:All FTB-800series turbine meters are constructed of stainless steel and CD4MCU.The operator must ensure that the operating fluid is compatible with these materials.Incompatible fluids can cause deterioration of internal components and cause a reduction in meter accuracy.Pulsation andVibration:Severe pulsation and mechanical vibration will affect accuracy and shorten the life of the meterFiltration:If small particles are present in the fluid,it is recommended that a strainer be installed upstream of the meterOutput:4to 20mA outputTwo wires from the flow sensor,24V+and 24V-,connect other instrument which can supply 24VDC.WARNING:Pressure in excess of allowable rating may cause the housing to burst and cause serious personal injury.2Overall DimensionTurbine Flow sensor Dimensions:mmModel No.L HFTD-804-I225141FTB-806-I225141Model No.L H TFTD-810-I345141NPT1/2"3Model No.L d T FTB-815-I7515NPT1" FTB-830-I12032NPT1-1/2" FTB-840-I14040NPT2"4Installation RequirementsFlow meter may be installed horizontally or vertically.In the latter case the fluid shall be flowing from downward and fulfill the pipe to avoid bubbles;the flowing direction of liquid shall be consistent with the direction indicated by the arrow on casing of the sensor;as far as front and rear straight pipe sections are concerned(see Fig.6),at upstream there shall be front straight pipe section at least10times of nominal drift diameter in length and at downstream no less than5times of nominal drift diameter in length.The internal wall of pipe sections shall be smooth and clean,free of defects such as indent,fouling and peeling.The pipe axis of the sensor shall be aligned with that of the neighboring pipe and the washers used for connection and sealing may not be embedded into depth of the pipe cavity;the sensors shall be kept away from foreign electric field and magneticfield,effective shielding measures shall be taken in case of necessity to avoid external interference.In order that the normal transfer of liquid will not be affected by maintenance,it is recommended that bypass pipes be installed at position of sensor.In case of open air installation,water proof measures shall be taken for purpose of amplifier and plug of the sensor.The wiring between sensor and display instrument is shown in Fig.5.When fluid contains impurities,filter shall be additionally installed.The number of filter screen meshes is determined in accordance with the flow and impurity,normally 20to60meshes.When fluid is mixed with free gases,gas eliminator shall be additionally installed.The complete pipe system shall be well sealed.The user shall fully understand the erosion nature of the measured medium to protect the sensor from being eroded.Fig.6Requirements on straight pipe section for installation of flow meter56Operation◆When sensor is used,the liquid to be measured shall be clean and free of impurities such as fiber and granules.◆When sensor is used,it shall be at first slowly filled with liquid,then open the outlet valve (which should be installed behind the flow meter).It is prohibited to render the sensor under impact of high-velocity fluid when it is not filled with liquid.◆The maintenance interval for sensor is in general half a year.In case of maintenance and cleaning,attention shall be paid not to damage the parts in the measuring cavity,particularly the impeller.During assembly,watch carefully the positional relation between guide part and impeller.◆When the sensor will be out of service for a long time,the internal liquid shall be cleaned.After dried,the sensor shall be provided with protection sleeves at both ends to protect against dust and it shall be placed in dry conditions for storage.◆The associated filter shall be cleaned on regular basis and the internalliquid shall be cleaned when it is out of service for a long time.Similar to sensor,the filter shall also be provided with dust protection and stored in dry conditions.◆The transmission wire of sensor may be overhead or buried (iron bushing shall be provided in the latter case).◆Prior to installation of sensor,the connection thereof with display instrument or oscilloscope shall be finished.Then switch on the power,blow the impeller or move the im eller with hand to make it rotate uickl ,see if there is an readin .Install the sensor if there is reading.In case of no reading,the related sections shall be inspected to eliminate anyfault.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a trademark of OMEGA ENGINEERING, INC.© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1. P urchase Order number under which the product was PURCHASED,2. M odel and serial number of the product under warranty, and3. Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the followinginformation available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2. Model and serial number of the product, and3. Repair instructions and/or specific problems relative to the product.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoeverarising out of the use of the Product(s) in such a manner.Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at TEMPERATUREM U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & AssembliesM U Wire: Thermocouple, RTD & ThermistorM U Calibrators & Ice Point ReferencesM U Recorders, Controllers & Process MonitorsM U Infrared PyrometersPRESSURE, STRAIN AND FORCEM U Transducers & Strain GagesM U Load Cells & Pressure GagesM U Displacement TransducersM U Instrumentation & AccessoriesFLOW/LEVELM U Rotameters, Gas Mass Flowmeters & Flow ComputersM U Air Velocity IndicatorsM U Turbine/Paddlewheel SystemsM U Totalizers & Batch ControllerspH/CONDUCTIVITYM U pH Electrodes, Testers & AccessoriesM U Benchtop/Laboratory MetersM U Controllers, Calibrators, Simulators & PumpsM U Industrial pH & Conductivity EquipmentDATA ACQUISITIONM U Communications-Based Acquisition SystemsM U Data Logging SystemsM U Wireless Sensors, Transmitters, & ReceiversM U Signal ConditionersM U Data Acquisition SoftwareHEATERSM U Heating CableM U Cartridge & Strip HeatersM U Immersion & Band HeatersM U Flexible HeatersM U Laboratory HeatersENVIRONMENTALMONITORING AND CONTROLM U Metering & Control InstrumentationM U RefractometersM U Pumps & TubingM U Air, Soil & Water MonitorsM U Industrial Water & Wastewater TreatmentM U pH, Conductivity & Dissolved Oxygen InstrumentsM7565/0421。

Omega Pt100 RTD 电阻温度传感器及热线温度传感器产品说明书

Omega Pt100 RTD 电阻温度传感器及热线温度传感器产品说明书
Thermocouples:
1-Class 1 (standard)
Diameter
Probe Length
6-6mm 3-3mm 2-2mm
5-200mm 200-500mm
Mounting Bush
O-Plain stem M6-M6x1 pitch M8-M8x1 pitch M10-M10x1 pitch G1/8-1/8" BSP PI. G1/4-1/4" BSP PI. G1/2-1/2" BSP PI.
Stem Diameter
6mm 3mm 2mm
Stem Length
5-200mm 201-500mm
Process Connection**
Plain stem (Standard) M6 x 1mm pitch thread (Ø3mm probes) M8 x 1mm pitch thread (Ø3mm-Ø6mm probes) M10 x 1mm piktch thread (Ø3mm-Ø6mm probes) 1/8" BSP Parallel (G1/8" – Ø3mm-Ø6mm probes) 1/4" BSP Parallel (G1/4" – Ø3mm-Ø6mm probes) 1/2" BSP Parallel (G1/2" – Ø6mm probes)
Ordering example 2: P-M-1/3-6-100-M10-S-8 Pt100 closed end probe with 1/3 DIN accuracy and diameter of 6mm. The probe length is 100mm with an M10 x 1 mounting bush and 8 metres of silicone lead wire.

美国OMEGA高精度S型称重传感器

美国OMEGA高精度S型称重传感器

电气连接:6 m (20')接线:
红:(+)激励 黑:(-)激励 绿:(+)输出 白:(-)输出
高精度S 型称重传感器
坚固耐用,适合工业应用
25 ~ 10,000 lb 的容量 11 ~ 4536 kgf 的容量
U 高精度U 含5测量点校准U 互换性达0.25%,适合多种称重传感器应用U 1000 lb 以内量程采用轻质铝结构U 更大量程采用坚固的不锈钢
规格
激励:10 Vdc (最大值为15V )输出:3 mV/V ±0.25%
校准:在张力方面的5校准点
(0%、50%、100%、50%、0%)线性度:±0.03%滞后性:±0.02%重复性:±0.01%
蠕变(20分钟):±0.03%
工作温度:-18 ~ 71ºC (0 ~ 150ºF)补偿温度:17 ~ 71ºC (60 ~ 160ºF)
LCR-1K ,
图片为实际尺寸。

LCR-2K ,图片为实际尺寸。

杆端,
REC-012M , 单独销售。

LBC-012负载按键, 单独销售。

热效应:
零点:±0.0027% FS/ºC 跨距:±0.0015% rdg/ºC 安全过载:容量的150%极限过载:容量的300%电桥电阻:350 Ω(标称)防护等级:IP55材质:
量程在1000 lb 以内:铝
量程超过1000 lb :17-4 PH 不锈钢
LCR 系列
经济型S型称重传感器。

J-11OMEGA 无线红外温度传感器说明书

J-11OMEGA 无线红外温度传感器说明书

OMEGA’s new infrared sensor with wirelesstransmitter features a remote IR sensor and radio wireless transmitter in a NEMA enclosure. The miniature sensor head is ideal for measuring temperatures from -18 to 538°C (0 to 1000°F) in confined, hard-to-reach places and harshenvironments. The wireless transmitter is mounted in a NEMA 4 (IP65) plastic enclosure. When activated the unit will transmit readings continuously at pre-set time interval that was programmed by the user during the initial setup. Each unit measures and transmits: IR sensor reading, ambient temperature, RF signal strength and battery condition to the host and is displayed on the PC screen in real time using the provided software. Each unit includes free software that converts your PC into a strip chart recorder ordata logger so readings can be saved and later printed or exported to a spread sheet file.Operating TemperatureWireless Transmitter: -10 to 70°C (14 to 158°F)Sensor Head: 0 to 70°C (32 to 158°F)Sensor Head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F)Operating Relative Humidity: Less than 95% RH, non-condensingWater Flow Rate (OS100-WC): 0.25 GPM, room temperature Thermal Shock: About 30 minutes for 25°C (77°F) abrupt ambient temperature change Warm-Up Period: 3 minutesAir Flow Rate (OS100-AP):1 CFM (0.5 L/s)Battery Life (Typ): 1.5 @ 1 sample/minute reading rate @ 25°C (77°F)Laser Sight Accessory (OS100-LS)Wavelength (Color): 630 to 670 nm (red)Operating Distance (Laser Dot): Up to 9.1 m (30')Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperatureEuropean Classification: Class 2, EN60825-1/11.2001Specifications(See for complete specifications)Temperature Range: -18 to 538°C (0 to 1000°F)Accuracy @ 22°C (72°F) Ambient Temperature and Emissivity of 0.95 or Greater: ±2% rdg or 2.2°C (4°F), whichever is greaterOptical Field of View: 6:1 (distance/spot size)Sensor Head Cable: 1.8 m (6') standard; up to 15 m (50') total length capable Repeatability: ±1% rdgSpectral Response: 5 to 14 micronsResponse Time: 100 ms (0 to 63% of final value)Emissivity Range: 0.1 to 1.00, adjustableU -18 to 538°C (0 to 1000°F) Measurement Range U A djustable Emissivity from 0.10 to 1.0U F ree Software ConvertsYour PC Into a Multi- Channel Chart Recorder or Data Logger U L ow Power Operation and Sleep Mode For Long Battery Life U W eather Resistant NEMA 4X (IP65) EnclosureF C C /I n d u str y C a n a d a A p p r o v e dF o r A v ai l a b l e R e c e i v er s , S e e o me g a .c o mUWIR-2-NEMA shown smaller thanactual size.IR sensor head.W e a t h e rP r o o f /W al lM o u n t ed Non-Contact Infrared Temperature SensorWith Wireless Transmitter6:1 spot size ratioOS100-AP air purge collar to keep the lens free of particles or debris.Both shown smallerthan actual size.Maximum Operating Current: 45 mA @ 3 VdcFDA Classification: Complies with 21 CFR 1040.10, Class II laser product Beam Diameter: 5 mm (0.20")Beam Divergence: <2 mradOperating Temperature: 0 to 50°C (32 to 122°F)Operating Relative Humidity: Less than 95% RH, non-condensingbattery assembly.Ordering Examples: UWIR-2-NEMA, wireless infrared transmitter, UWTC-REC1, 48-channel USB receiver, UWTC-BATT-C, spare battery, and OS100-MB, sensor head bracket.UWIR-2-NEMA, wireless infrared transmitter, UWTC-REC2-D-MA, 48-channel transceiver/host with 1-channel 4 to 20 mA analog output, alarm and local display, UWTC-BATT-C, spare battery, and OS100-MB, sensor head bracket. OCW-3, OMEGACARE SM extends standard 1-yearwarranty to a total of 4 years.Power:(1.5 x 2")LASER RADIATION - DO NOT STARE INTO BEAM CAUTIONTYPE AND RULES PRINT BLACK 100%BACKGROUND YELLOW 100%Shown actual size.OS100-LS laser sight fits in front of the IR head for accurate positioning.。

Omega FP-5300系列流量传感器说明书

Omega FP-5300系列流量传感器说明书

Streamline your flow measurement operation with the FP-5300 Series flow sensor. Using this compact flow sensor, a matched sensor installation fitting, an OMEGA®flow meter or controller, and ordinary handtools, you canassemble a complete flow monitoring or controlling system in minutes. Accurate to ±0.2 fps, with repeatability at ±0.1 fps, this insertion sensor operates on a simple electromechanical principle, proven in thousands of liquid flow applications worldwide. It all adds up to precision, dependability, and convenience– basic advantages that are quickly surpassing its in-line competition.A TimesAver YouCAn BAnk onConvert your maintenance hours into minutes with the FP-5300. Should a sensor, rotor, or O-ring need to be replaced, it takes only seconds. Reduce your system downtime substantially with a stand-alone FP-5300 sensor, or simply add a Wet Tap Assembly and eliminate downtime completely. Combined with the FP-5300 during initial installation, the Wet Tap allows sensor removal without system shut-down. Optional local or remote capability lets you place your meter up to 200 feet away without signal amplification, and you can install the FP-5300 in pipe sizes ranging from 1⁄2 inch to 36 inches withouta lot of additional cost, because the price of the FP-5300 increases only slightly for larger pipe sizes.rugged ConsTruCTion For Long WeArAvailable in a choice of chemically resistant, non-contaminating housing materials, the FP-5300 stands up to the harshest environments. The glass-filled polypropylene housing version is lightweight but strong, which makesit ideal for handling a wide range of liquids, including corrosive fluids in chemical processing. For processes involving acids and solvents, the PVDF (polyvinylidene fluoride) housing version is a tough fluorocarbon that is highly resistant to more severe fluids. (Visit /fp5100 for more information on OMEGA’s all-PVDF flow monitoring systems.)FP-5300shownactual size.THE FL0W SENSOR THAT MAKES SHORT WORK OF YOUR FLOW MEASUREMENTS Paddlewheel Flow SensorsF-XF-XFCommon sPeCiFiCATionsAccuracy: ±1% full scale output signal: 1 V p-p/fpsoutput Frequency: 6 Hz/fps nominal Flow rate range: 1 to 20 fps source impedance: 8 K Ωmaximum Pressure:FP-5300 Series: 180 psig max @ 20°C (68°F)FP-5100 Series: 200 psig max @ 20°C (68°F)minimum Temperature: 0°C (32°F)maximum Temperature: See chart on previous page for complete temperature and pressure rating Pressure drop: Equal to 2.5 m (8') of straight pipematerial: Transducer Housing: glass-filled polypropylene; O-Rings: FKM;Shaft: Titanium (PVDF opt.); Rotor: PVDF maximum % solids: 1% of fluid volume, non-abrasive, nonmagnetic, <100 micron diameter and length standard Cable Length: 7.5 m (25')max viscosity: 1 centipoise (water); up to 5 cp above 5 fps velocitysee for compatible fittings.dPF701Pipe installation fitting not included. See for required fittings.Comes complete with operators manual.Ordering Examples: FP-5300, paddlewheel sensor, plus FP-5310M , 1" PVC fitting (see ).FP-5301 sensor, plus FP-5350GI , 5" Galvanized Iron saddle fitting (see ).Flow measurement simple and AccurateThe sensor works on a simple but preciseelectromechanical principle based on measuring the rate and volume of flow in your pipe. Four permanent magnets, imbedded in the rotor blades, spin past a coil in the sensor body. As the fluid flow causes the rotor to move, a sine wave signal is produced, directly proportional to the flowrate. The patented “open cell” feature of the rotor ensures a linear, repeatable output, up to 23 fps, with accuracy of ±0.2 fps. The result is minimal head loss and no cavitation.F-XPRESSURE/TEMPERATURE CHARTSFor FP-5100, FP-5200, FP-5300 and FP-8500 Series Sensors and Associated FittingsnoTe: All pressure/temperature ratings listed are for water under non-shock conditions with no pressure cycling. Various chemicals and cycling pressures up and down can weaken plastics. Fittings must be installed so that the fitting does not carry the weight of the piping and does not suffer from thermal expansion stresses. Water hammer, fluid surges, and cavitation must always be avoided. If the end user elects to thread the plastic fittings with socket ends, the pressure rating will be substantially decreased.FP-5100, FP-5300 and FP-8500 series sensorsPressure/Temperature ratingsWARNING: THE ABOVE PRESSURE/TEMPERATURE CURVES ARE SPECIFICALLY FOR THE FP-5100. FP-5300, AND FP-8500 SENSORS. DURING SYSTEM DESIGN, THE SPECIFICATIONS OF ALLCOMPONENTS MUST BE CONSIDERED. IN A METAL PIPING SYSTEM, A PLASTIC SENSOR WILL REDUCE THE SYSTEM SPEC. ON THE OTHER HAND, IF USING A PVDF SENSOR IN A PVC PIPING SYSTEM, THE FITTING WILL REDUCE THE SYSTEM SPEC.PvC and CPvC Tees and saddlesThese ratings are for PVC and PVDF fittings. For all metal fittings 10" and larger, a PVC insert is used; for 8" and below, a PVDF insert is used. Use the appropriate curve to determine the maximum pressure rating of these fittings.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Omega称重传感器广州南创房工Omega称重传感器公司简介Omega称重传感器自1962年成立以来,已经成长从生产热电偶单一产品线建立在技术市场的全球领导者,提供超过10万个最先进的产品用于测量和控制温度,湿度,压力,应变,力,流量,液位,pH值和电导率。

自成立以来,Omega称重传感器的产品远销38个国家,在多个国家设立了分支机构或办事处,生产基地遍布美洲、东欧、中国等地;并在中国设立了广州南创传感器事业部,可为用户的实验和生产提供最佳的服务与解决方案。

Omega称重传感器公司总部设在康涅狄格州斯坦福德,在位于新泽西州的布里奇波特。

Omega®除了其在英国的子公司,也有在加拿大的网站,Omega工程有限公司,英国Omega集团还包括纽波特电子(网站在纽波特,美国,德国,法国,荷兰和捷克共和国),OMEGADYNE(位于美国俄亥俄州哥伦布市附近)以及Omega万泽蒂(在波士顿,马萨诸塞州)。

在过去的40年Omega®已经从出身卑微,成为在过程测量和控制领域的国际领先地位,提供超过10万件。

Omega称重传感器图片:Omega称重传感器以上内容技术参数以《OIML60号国际建议》92年版为基础,最新具体变化可查看《JJG669—12 Omega广州南创传感事业部检定规程》1.英国Omega流量计S型称重传感器 (load cells)LC101:25lbs,50lbs,100lbs,200lbs,250lbs,500lbs,1Klbs,2Klbs,2.5Klbs,3Klbs,5Klbs,1 0Klbs,20Klbs,25Klbs,30Klbs,40KlbsLC105:25lbs,50lbs,100lbs,200lbs,250lbs,500lbs,1Klbs LC115:250lbs,500lbs,1Klbs 2.英国Omega流量计梁式称重传感器LC501:100lbs,200lbs,500lbs,750lbs,1Klbs,2Klbs,2.5Klbs,5Klbs,10Klbs,20Klbs,50Klb s,80Klbs,100Klbs LC509:5lbs,10lbs,15lbs,25lbs,50lbs,100lbs LC601:±1lbs,±2lbs,±5lbs,±10lbs,±25lbsLC602:50lbs,100lbs,250lbs,500lbs,1Klbs,2Klbs,2.5Klbs,LCM602:25lbs,50lbs,250lbs,500lbs,750lbs,1Klbs,2.5Klbs,5Klbs3.英国Omega流量计压式称重传感器LC302:25lbs,50lbs,100lbs,250lbs,500lbs,1KlbsLC304:100lbs,500lbs,1Klbs,3Klbs,5Klbs,7.5Klbs,10KlbsLC305:25lbs,50lbs,100lbs,200lbs,500lbs,1Klbs,2Klbs,2.5Klbs,5Klbs,10Klbs,20Klbs LC315:25lbs,50lbs,100lbs,200lbs,500lbs,1Klbs,2Klbs,2.5Klbs,5Klbs,10Klbs,20Klbs LC307:250lbs,500lbs,1Klbs,2Klbs,3Klbs,5Klbs,7.5Klbs,10Klbs,50Klbs,100KlbsLC321:250lbs,500lbs,750lbs,1Klbs,2KlbsLCGC:50g,150g,250g,500g,1KG,5lbs,10lbs,25lbs,50lbsLCGD:25lbs,50lbs,100lbs,250lbs,500lbs,1Klbs,2Klbs,5Klbs,10Klbs,15Klbs,20Klbs,30 Klbs,50Klbs LCKD:1KG,5lbs,10lbs,25lbs,50lbs,100lbs,250lbs,500lbs,1000lbs LCM302:100N,200N,500N,1KN,2KN,5KNLCM304:100N,200N,300N,500N,2KN,5KN,10KN,20KN,50KNLCM305/315:100N,200N,500N,1KN,2KN,10KN,20KN,50KNLCMGD:100N,200N,500N,1KN,2KN,5KN,10KN,20KN,50KN,60KN,80KN,120KN,200KNLCMKD:10N,20N,50N,100N,200N,500N,1KN,2KN,5KN4.英国Omega流量计拉式称重传感器LC701/711:100lbs,250lbs,750lbs,1Klbs LC702:5Klbs,10Klbs LC712:5Klbs,10Klbs,50Klbs,100Klbs LC703:±10lbs,±25lbs,±50lbs,±75lbs,±100lbs,±150lbs,±200lbs,±300lbs,±500lbs,±750lbs,±1Klbs5.英国Omega流量计柱式称重传感器LC1001/1011:1Klbs,5Klbs,10Klbs,50Klbs LC1102/1112:5Klbs,10Klbs,50Klbs,100Klbs LC1103/1113:5Klbs,10Klbs,50Klbs6.英国Omega流量计拉压式称重传感器LC201:25lbs,50lbs,75lbs,100lbs,300lbs LC202:±25lbs,±50lbs,±100lbs,±300lbs,±500lbs,±1Klbs,±2Klbs,±3Klbs,±5Klbs,±7.5Klbs,±10Klbs LC203/213:25lb,50lb,100lb,200lb,500lb,1Klb,2Klb,2.5Klb,5Klb,8Klb,10KlbLC204/214:25lb,50lb,100lb,200lb,500lb,1Klb,2.5Klb,5Klb,8Klb,10KlbLC703:10lb,25lb,50lb,75lb,100lb,150lb,200lb,300lb,500lb,750lb,1KlbLCFA:50g,150g,250g,500g,1000g5lb,10lb,25lb,50lb,100lb,250lb,500lb,1Klb,2Klb,3Klb,4Klb,5Klb,7.5Klb,10Klb LCFD:±1KG,±5lb,±10lb,±25lb,±50lb,±100lb,±250lb,±500lb,±1Klb LCM202:100N,200N,300N,500NLCM203/213:100N,200N,500N,1KN,2KN,5KN,10KN,20KN,50KNLCM703:5lb,10lb,25lb,50lb,75lb,100lb,150lb,250lb,500lbLCMFD:10N,20N,50N,100N,200N,500N,1KN,2KN,5KN7.英国Omega流量计轮辐式称重传感器LC401/411:1Klb,5Klb,100KlbLC402/412:50lb,100lb,250lb,500lb,1Klb,2Klb,3Klb,5Klb,10KlbLCHD:5lb,10lb,25lb,50lb,100lb,250lb,500lb,1Klb,2Klb,3Klb,4Klb,5Klb,7.5Klb,10Klb ,15Klb,20Klb,30Klb,50Klb,100Klb8.英国Omega流量计通孔称重传感器LC8100-200:5lb,10lb,25lb,50lb,100lb,200lbLC8125-312:25lb,50lb,100lb,250lb,500lbLC8150-250:100lb,250lb,500lb,1Klb,2Klb,3Klb,5Klb, LC8150-500:250lb LC8151-500:3Klb,5Klb,10Klb,20Klb LC8151-750:100lb,250lb LC8251-126:50Klb,75Klb,100Klb LC8301-126:75Klb,100Klb LC8302-151:150Klb LC8200-125:5lb,10lb,25lb,50lb,100lb LC8200-250:3Klb,5Klb LC8200-375:25lb,7.5Klb,10Klb LC8200-500:3Klb,5Klb,10Klb LC8200-625:50lb,250lb,500lb,1Klb LC8200-875:3Klb LC8200-1.00:500lb,1Klb,2Klb LC8250-750:1Klb,3Klb,5Klb LC8250-1.00:10Klb LC8250-1.25:1Klb LC8250-500:15Klb LC8300-1.13:1Klb,3Klb LC8300-1.25:5Klb,20Klb LC8300-1.00:50Klb,100Klb LC8313-200:500lb,5Klb LC8313-213:5Klb LC8400-200:25Klb,50Klb,100Klb LC8400-213:10Klb,25Klb,200Klb LC8450-313:5Klb LCM901-6:10KN,20KN LCM901-10:50KN LCM901-13:130KN LCM901-16:200KN LCM901-19:300KN LCM901-38:500KN LCM911-13:130KN LCM901-16:200KN LCM901-19:300KN LCMWD:1KN,2KN,5KN,10KN,20KN,50KN,100KN,200KN LCWD:500lb,1Klb,2Klb,5Klb,10Klb,20Klb,50Klb,100Klb,200KLb9.英国Omega流量计称重模块TWA5:100lb,200lb,500lb,750lb,1Klb,2Klb,3Klb,5Klb,10Klb,20Klb(碳钢) TWA6:100lb,200lb,500lb,750lb,1Klb,2Klb,3Klb,5Klb,10Klb,20Klb(不锈钢)。

相关文档