URY2D102MHD中文资料

合集下载

GBPC102中文资料

GBPC102中文资料

GBPC1005 THRU GBPC110GLASS PASSIVATED SINGLE-PHASE BRIDGE RECTIFIERReverse Voltage -50 to 1000 Volts Forward Current - 3.0 AmperesFEATURES♦ Plastic package has Underwriters Laboratory Flammability Classification 94V-0♦ This series is UL listed under Recognized Component Index,file number E54214♦ Glass passivated chip junctions♦ High case dielectric with standing voltage of 1500 V RMS ♦ T ypical I R less than 0.1µA ♦ High surge current capability ♦ Ideal for printed circuit boards♦ High temperature soldering guaranteed:260°C/10 seconds, 0.375" (9.5mm) lead length, 5lbs.(2.3kg) tensionMECHANICAL DATACase:Molded plastic body over passivated junctions Terminals:Plated leads solderable per MIL-STD-750, Method 2026Mounting Position:Any (NOTE 1)Mounting Torque:5.0 in.- lb.max.Weight:0.1 ounce, 2.8 gramsMAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICSRatings at 25°C ambient temperature unless otherwise specified.GBPC GBPCGBPC GBPC GBPC GBPC GBPC SYMBOLS 1005 101102104106108110UNITSMaximum repetitive peak reverse voltage V RRM 501002004006008001000Volts Maximum RMS bridge input voltage V RMS 3570140280420560700Volts Maximum DC blocking voltage V DC 501002004006008001000Volts Maximum average forward T C =60°C (NOTE 2) 3.0rectified output current atT A =25°C (NOTE 3)I (AV) 2.0Amps Peak forward surge current single sine-wavesuperimposed on rated load (JEDEC Method) T C =60°C I FSM 60.0Amps Rating for fusing (t<8.3ms)I 2t 15.0A 2sec Maximum instantaneous forward voltage drop per leg at 1.5 AmperesV F 1.0Volts Maximum DC reverse current at rated T A = 25°C 5.0DC blocking voltage per legT A =125°CI R 500.0µA Typical junction capacitance per leg (NOTE 4)C J 21.0pF Typical thermal resistance per leg (NOTE 2)R ΘJA 12.0R ΘJC 8.0°C/W Operating junction and storage temperature rangeT J,T STG-55 to +150°CNOTES:(1) Bolt down on heat-sink with silicone thermal compound between bridge and mounting surface for maximum heat transfer with #6 screw (2) Unit mounted on 4.0 x 4.0 x 0.11" thick (10.5 x 10.5 x 0.3cm) Al. Plate(3) Unit mounted on P.C.B. at 0.375" (9.5mm) lead length with 0.5 x 0.5" (12 x 12mm) copper pads (4) Measured at 1.0 MHz and applied reverse voltage of 4.0 VoltsPolarity shown on side of case: Positive lead by beveled cornerCase Style GBPC1Dimensions in inches and (millimeters)4/98。

URY1C102MHD中文资料

URY1C102MHD中文资料

63 0.10
100 0.08
160 ~ 350 400 ~ 450 0.20 0.25 400 6 10 450 15
Measurement frequency : 120Hz
Stability at Low Temperature
Rated voltage ( V) Impedance ratio Z– 25˚C / Z+20˚C ZT / Z20 (MAX.) Z– 40˚C / Z+20˚C
12.5 × 12.5 18 × 12.5 22 × 12.5
400 550 610
12.5 × 12.5 22 × 12.5
230 400
12.5 × 12.5 16 × 12.5 20 × 12.5 25 × 12.5
130 210 280 360
315 2F 12.5 × 12.5 16 × 12.5 20 × 12.5 25 × 12.5
2 3
63~ 100 160 ~ 200 250 ~ 350 2 3 4 3 4 8
Endurance
After 2000 hours' application of rated voltage at 105°C, capacitors meet the characteristic requirements listed at right.
After storing the capacitors under no load at 105°C for 1000 hours, and after performing voltage treatment based on JIS C 5101-4 clause 4.1 at 20°C, they will meet the specified value for endurance characteristics listed above. Printed with white color letter on black sleeve.

工业机器人设备清单

工业机器人设备清单

空气动力机械智能制造公共实训基地设备预算清单模块一工业机器人基础工作室一、工业机器人基本技能工作室总体概述工业机器人基本技能实训方案以6轴机器人工作站为核心,配套装配了操作对象承载平台、工具墙、零件箱、学习讨论区、资讯区、机器人安全工作围栏等设施设备及基础教材、仿真软件、工学结合工作页等教学配套。

为工业机器人基本技能实训提供了综合的、完整的、工学结合的解决方案。

针对工业机器人应用维护专业基础技能训练与实习,该阶属于机电工学结合类技能向工业机器人过渡的关键环节,通过简单易操作的机器人本体操作的学习,加强安全意识与规范意识的培养,让学生掌握如何与工业机器人“打交道”。

工业机器人基本技能工作室案例照片(仅供参考)(图片仅供参考、以实际二、工业机器人基本技能工作室配置清单个;高强度铝合金手电筒(3节7号电池)6LED 1个;专业级手动黄油枪400cc 1个;手用黄油枪尖嘴头 1个;手用黄油枪软管12" 1个;德式轴用直口卡簧钳7" 1把;活动扳手10" 1把;木柄安装锤45MM 1把;T 系列双头螺丝批#1&5MM×150MM 1个;2.5MM系列钢柄快脱棘轮扳手 1把;预置式扭力扳手3件套;9件套公制长球头内六角扳手 1套;塑料工具箱19" 1把;吊带1条;卸扣 2个;工业听诊器 1把10、护栏①范围:2980mm×2980mm×920mm②材质:铝型材★含工业机器人拆装与调试课程资源包1、《工业机器人拆装与调试》教材配套教学ppt一套,试题3套、课程标准1套(现场演示)2、★《工业机器人拆装与调试》跨终端网络课程1门:★基于html5开发,课程栏目满足自适应,功能栏目为首页、课程简介、课程学习、★模拟考试(可进行在线考试)、拓展资源;(现场演示)3、《工业机器人拆装与调试》网络课程符合scorm封装标准4、★7个机器人拆装重难点微课;(现场演示)5、批量六关节机器人拆装素材库、视频素材库、教材配套素材库6、提供资源能学辅教,设备与网络课程及资源库能够完整对应。

ERJ120102Y中文资料(panasonic)中文数据手册「EasyDatasheet - 矽搜」

ERJ120102Y中文资料(panasonic)中文数据手册「EasyDatasheet - 矽搜」

3GE : 0603 0.1 W
6GE : 0805 0.125 W
8GE : 1206 0.25 W
14 : 1210 0.5 W
12 : 1812 0.75 W
12Z : 2010 0.75 W
1T : 2512
1W
Marking
Code
Marking
Y Value Marking on black side
U
Embossed CarrierTaping ERJ12
4 mm pitch
ERJ12Z
ERJ1T
芯片中文手册,看全文,戳
厚膜片式电阻器
■ 施工
Protective coating Alumina substrate
Thick film resistive element
■ 额定值
3.6到4
6.2 to 7
ERJ1T(2512)
5至5.4
7.6至8.6
c 0.20 to 0.25 0.25 to 0.35 0.4到0.6
0.8至1 0.9 to 1.4 1.2至1.8 1.8到2.8 2.3 to 3.5 1.8到2.8 2.3 to 3.5
■ 推荐焊接条件
建议及注意事项如下所述.
0.20
0.10
0.10
0.13
0.04
ERJ1G (0201)
0.60
0.30
0.10
0.15
0.23
0.15
ERJ2G (0402)
1.00
0.50
0.20
0.25
0.35
0.8
ERJ3G (0603)
1.60
0.80
0.30

WONDER V-102 说明书

WONDER V-102 说明书
日曆……………………………….……………………… 64 待辦事項………………………….……………………… 64 鬧鐘……………………………….……………………… 65 世界時間………………………….……………………… 66
14. 網路服務 …………………………………….……...67
STK………………………………..……………………... 67 WAP………………………………..…………………….. 67 帳號資料…………………………..……………………... 68
(2)訊息 (3)通話記錄
簡訊
收件箱 寄件箱 寫訊息 範本 訊息設定
多媒體訊息
寫訊息 收件箱 寄件箱 草稿箱 範本 訊息設定
聊天
聊天室一
聊天室二
語音郵件
VOICE.MAIL
廣播訊息
接收模式
讀取廣播訊息
語言
頻道設定
未接電話
已撥電話
已接電話
刪除通話記錄 未接電話
鈴聲連結 來電群組
訊息設定組 一般設定 記憶體狀態 儲存處 訊息傳送設定
15. 附加功能…………………………………………….69
計算機…………………………………………………..… 70 單位換算………………………………..………………… 70 貨幣換算………………………………….….…………… 71 健康管理…………………………………..……………… 71
16. 快捷功能設定……………………..…………………73 17. 疑難解答………………..……………………………74 18. 注意事項……………….…………………………….76
按鍵 −
說明
分別執行螢幕左下方及右下方所顯示的功能 λ 傳送/應答一個呼叫 λ 在待機狀態下,按該鍵調出通話記錄列表。如果

迈瑞欧恒温恒湿电子防潮箱(低温加热型)选型手册与技术参数说明书

迈瑞欧恒温恒湿电子防潮箱(低温加热型)选型手册与技术参数说明书

恒温恒湿电子防潮箱(低温加热型)选型手册与技术参数(控湿范围:20%-60%,10%-20%,1%-10%RH三选一;控温范围:10~40℃)100L165L246L325L435L546L720L878L1440L(四门)1440L(六门)非防静电型号防静电型号外形尺寸(W*D*H)内部尺寸(W*D*H)平均功率(W)最大功率(W)层板数量容积(L)MC108T MC108TF448*400*688mm446*372*598mm13911100 MC168T MC168TF448*450*1010mm446*422*848mm181263165 MC268T MC268TF598*400*1310mm596*372*1148mm181263246 MC328T MC328TF900*450*1010mm898*422*848mm201403325 MC468T MC468TF900*600*1010mm898*572*848mm201403435 MC568T MC568TF598*710*1465mm596*682*1298mm201403546 MC718T MC718TF598*710*1910mm596*682*1723mm201405720 MC878T MC878TF900*600*1890mm898*572*1698mm201405878 MC1368T MC1368TF1200*710*1910mm1198*682*1723mm4028051440 MC1369T MC1369TF1200*710*1910mm1198*682*1723mm4028051440 *白色为非防静电系列;黑色为防静电系列,型号后带有F。

产品特性:1.加热器采用德国进口的DBK加热器,该加热器通过德国TUV,欧洲CE,美国UL 认证,符合ROHS环保。

质量好,温升效率高,使用寿命长。

70度时平均无故障时间(MTTF)为65000小时。

锐德超声MX2辅助诊断仪器租赁说明书

锐德超声MX2辅助诊断仪器租赁说明书

920-218B-ENThe Standard in Phased Array, Redefined•Bright, Large-Size Screen •Fast, Intuitive Touch-ScreenInterface •Advanced Weld Overlay •High-Capacity Data Storage •Fast File Transfer•NEW OmniPC Analysis SoftwareAdvanced Test Equipment Rentals 800-404-ATEC (2832)®E s t a b l i s h e d 1981The Standard in Phased Array, RedefinedThe result of over 10 years of proven leadership inmodular NDT test platforms, the OmniScan MXhas been the most successful portable and modularphased array test instrument produced by Olympusto date, with thousands of units in use throughoutthe world.Building on a Solid BasisThis second generation OmniScan MX2 increasestesting efficiencies, ensuring superior manual andadvanced AUT application performance with fastersetups, test cycles, and reporting, in addition to uni-versal compatibility with all phased array and ultra-sound modules: past, present and future. Designedfor NDT leaders, this high-end, scalable platformdelivers true next-generation NDT performance.The OmniScan MX2 offers a high acquisition rateand new powerful software features for efficientmanual and automated inspection performance—all in a portable, modular instrument.Faster Is Better!Powerstart your day the right way with theOmniScan MX2. The OmniScan MX2 simplifiesand speeds up the setup process with its new WeldOverlay software feature, so you can start testingimmediately. Featuring the industry-standard phasedarray user interface with faster-than-ever perfor-mance, a bigger and brighter 10.4 in. screen, newand unique intuitive touch-screen capabilities, andfaster data transfer, enabling you to get to your nextinspection quicker.More Rugged than EverThe OmniScan MX2 is now designed for IP66, andbuilt to withstand the drops, spills, and abuse thattypically occur in the most demanding inspectionenvironments.More than an Instrument—A Solution ProviderThe OmniScan MX2 is an important part of yourinspection solution, and can be combined withother critical components to form a completeinspection system. Olympus offers a completeproduct range that includes phased array probes,scanners, analysis software, and accessories, allof which are integrated and packaged into rapidlydeployable, application-specific solutions for quickreturns on your investment. In addition, Olympusoffers a high-quality calibration and repair serviceworldwide, which is backed by a team of phasedarray application experts to ensure that you get thesupport you need.Life-Size OmniScan MX23Touch-Screen InterfaceThe revolutionary touch-screen interface offers simple and quick navigation, enhancedtext input functions, and easier, faster cursor control and gate setup.Full-Screen ModeThe unique full-screen mode offers operators increased viewing comfort, in addition to better readability at a distance.This feature can be used in both acquisition and analysis mode.Weld Overlay WizardThe Weld Overlay Wizard facilitates the creation of industry-standard weld over-lays for analysis assistance and volumetric flaw placement.OmniScan MXOmniScan MX2100% brighter screen4Modular InstrumentBackward Compatible. Forward Compatible.An Evolving Platform for your Growing Needs.Designed to secure both your current and future phased array invest-ments, the OmniScan MX2 can house any Olympus phased array module, including the reliable, field-proven models currently available, and the next-generation modules of the future. Its open architecture also supports future software updates and phased array module upgrades with configurations from 16:64M to 32:128 to ensure that your instrument evolves with your testing needs, and that you get the most from your investment.Module Compatibility OmniScan MX2OmniScan MX OMNI-M-PA1664M✔✔OMNI-M-PA1664✔OMNI-M-PA16128✔✔OMNI-M-PA32128✔✔OMNI-M-PA32128PR✔✔OMNI-M-PA3232 (200 V)✔✔OMNI-M-UT✔✔OMNI-M-ECT/ECA✔Software CompatibilityMXU-3.X1✔MXU-2.X setup and data files✔✔TomoView 2.9R12 (or higher)1✔✔TomoView Remote Control✔✔1. Data file compatibilityUT2 UT4 UT816:64 PA M16:64 PA16:128 PA32:32 PA32:128 PA5 Zooming and PanningGate Selection and MovementCursor Selection and MovementThe touch screen’s zooming functions can be used to zoom in on a specific area.In Zoom mode, swipe to pan the window contents.eters.In Cursor mode, tap once on a cursor to select it. Double-tap on a posi-tion to move the cursor to the desired location.In Gate mode, tap and hold a gate to move it to a new position.Text and Value InputDouble-tap on a parameter to bring up the keyboards or keypad on which values can beentered. Alphabetic and a numeric keyboards are available.67SetupGroup Wizard for All Essential Parameters• Material selection, with a database for shear and longitudinal velocities, and configuration of components for flat or curved surfaces.• A group copy option in the Wizard for fast creation of symmetrical two-probe inspections.• Wedge selection from a database of Olympus wedges.• Auto probe detection.• Scanner configuration with offsets, skews, and probe positions.• Wizard guidance for phased array, conventional UT, and TOFD channels.• Detailed interactive and illustrated help menu for every step in the Wizard.• Weld Overlay and RayTracing: step-by-step Wizard to configure the weld geometry.Setup SpeedOmniScan MX OmniScan MX250% fasterS-Scan and A-Scan Display Refresh RateOmniScan MX OmniScan MX2300% betterCalibrationCode-Compliant CalibrationThe Calibration Wizards ensure that every focal law in every group is the direct equivalent of a single-channel conventional flaw detector.Calibration Wizards• Guide the user step-by-step through Velocity, Wedge Delay, Sensitivity, TCG, DAC, AWS, and DGS calibrations.• Enable experimental or theoretical sensitivity, and TCG curves based on two, three, or all beams for a real or interpolated calibration.• Offer a simple, easy-to-use interface that enables all focal laws to be visualized simultaneously for a particular calibration task.• Features an interactive help menu with detailed graphics and definitions, which is available in each step of each Wizard.Scan plan adjustment using the Focal Law Wizard.Sensitivity calibration for a defined section in a sectorial scan.Sensitivity calibration for all beams in a sectorial scan.UT parameter adjustment using the touch-screen software keypad.8Acquisition• A scan menu for quick and easy configuration of inspection parameters for manual, one-line, raster, and helicoidal scans.• Multiple encoder modes, including Clock, Quadrature, and Clicker.• C-scan configuration for amplitude and position C-scans, and display setup.• Data storage options for full A-scans, S-scans, and/or C-scans.• Preconfigured display layouts for easy inspection preparation.• PRF auto adjustments for optimized, maximum speed, or manually-controlled settings.• Data storage options for flash card or USB media devices.• Real-time data acquisition displays, with the ability to rewrite data in both scan directions when using an encoder.• Easy to interface with encoded scanners.• Different gate-synchronization capabilities.Pulse Repetition Frequency (PRF)OmniScan MX OmniScan MX240% betterSaving Inspection Data File to USB (speed)OmniScan MX OmniScan MX2Up to 400% betterMaximum File Size (Mb)OmniScan MX 160 MbOmniScan MX2300 MbFlawless Data ManagementAn SD Card is used to store data for easy transfer to a computer. The SD card can also be inserted and removed without having to reboot the unit. In addition, data can be transferred to exter-nal media using the USB 2.0 port. The OmniScan MX2 provides data transfer speeds up to 400% faster than the OmniScan MX (depending on the device used).Analysis• An extensive display menu for preconfigured multigroup and multiprobe inspection layouts.• Data, reference, and measurement cursors for defect sizing and reporting.• Extensive Readings database for trigonometry, flaw statistics on axes, volumetric position information, code-based acceptance criteria, corrosion mapping statistics, etc.• All Readings are available online, and are also available off-line when full A-scans are saved in data files.• Linked displays for interactive analysis of A-scans, B-scans, S-scans, and C-scans for multigroup and multiprobe inspections.• Optimized preconfigured layouts for quick and simple length, depth, and height sizing of flaws for code-based or non-code-based inspections.• Interactive off-line gate repositioning.Top: Data acquisition displaying TOFD. Right: Data acquisition displaying two phased array channels andTOFD.Weld inspection display showing the position of indications in the RayTracing display.This new software is the most efficient and affordable option for OmniScan data analysis,and features the same analysis tools provided in the OmniScan onboard software, with theOptimized use of your OmniScan: The OmniScan unit can now be used strictly forscanning while analysis is performed simultaneously on a personal computer.Same user interface as the OmniScan. An inspector with training on the OmniScan isCompatible with extra large screens for increased visibility during analysis.Intuitive keyboard shortcuts have been added to boost productivity levels9TomoView offers advanced post-processing of OmniScan Dual matrix PA probe (TRL).Indication table built from composite inspection data.11Typical ApplicationsGirth Weld InspectionThe OmniScan PA is at the heart of the Olympus manual andsemiautomated circumferential weld-inspection solutions developed for the oil and gas industry. These phased array systems, which are certified for tube inspection in compliance with ASME, API, and other code criteria, offer superior inspection speed and detection, andfacilitate interpretation of indications.Pressure Vessel Weld InspectionA complete inspection of pressure vessel welds can be performed in a single scan using an OmniScan PA and a motorized scanner such as the WeldROVER. By combining TOFD and PA in a single inspection pass, a significant reduction in inspection time can be achieved as compared with conventional raster scanning or radiography. Further-more, inspection results are available immediately, enabling you todetect problems with welding equipment and fix them right away.Weld Inspection of Small-Diameter PipesWhen coupled with the COBRA manual scanner, the OmniScan flaw detector is capable of inspecting pipes ranging from 0.84 in. OD to 4.5 in. OD. With its very slim design, this manual scanner is able to inspect pipes in areas with limited access. Adjacent obstructions such as piping, supports, and structures can be as close as 12 mm (0.5 in.).Manual and Semiautomated Corrosion MappingThe OmniScan PA sytem with the HydroFORM scanner is designed to offer the best inspection solution for detecting wall-thickness reduc-tions resulting from corrosion, abrasion, and erosion. In addition, it detects mid-wall damage such as hydrogen-induced blistering and manufacturing-induced laminations, and easily differentiates these anomalies from loss of wall thickness.For this application, phased array ultrasound technology offers supe-rior inspection speed, data point density, and detection.Composite InspectionParts made of laminate composite materials pose an inspection chal-lenge due to their various shapes and thicknesses.Olympus offers complete solutions for the inspection of carbon-fiber-reinforced polymer structures. These solutions are based on the OmniScan flaw detector, the GLIDER ™ scanner, and dedicated probesand wedges designed for CFRP flat panel and radius inspection.48 Woerd Avenue, Waltham, MA 02453, USA, Tel.: (1) 781-419-390012569 Gulf Freeway, Houston, TX 77034, USA, Tel.: (1) 281-922-9300505, boul. du Parc-Technologique, Québec (Québec) G1P 4S9, Tel.: (1) 418-872-11551109 78 Ave, Edmonton (Alberta) T6P 1L8*******************OmniScan_MX2_EN_201203 • Printed in Canada • Copyright © 2012 by Olympus NDT.*All specifications are subject to change without notice.All brands are trademarks or registered trademarks of their respective owners and third party entities.is ISO 9001 and 14001 certified.Compatible with the Following Inspection Codes:The OmniScan MX2 is compatible with standard industry inspection codes, including, but not limited to:ASME Section V , Article 4AWSAll ASME phased array code cases API 1104 and API RP2X ASTM E2700-09CEN EN 583-6ASTM E2491-06BSI BS7706… and moreOmniScan MX2 Specifications。

浩志崎冰淇淋机产品说明书

浩志崎冰淇淋机产品说明书

Hoshizaki“A Superior Degreeof Reliability”ModelsF-1500MAH(-C)F-1500MWH(-C)F-1500MRH(-C)Modular FlakerHoshizaki America, Inc.Number: 71223Issued: 11-11-2004Revised: 10-25-2011PARTS LISTCONTENTSAuxiliary Codes (3)Note About Ordering Parts (4)A. Ice Flaker Assembly (5)B. Ice Making Unit (9)C. Refrigeration Circuit (12)F-1500MAH(-C) (12)F-1500MWH(-C) (14)F-1500MRH(-C) (16)D. Water Circuit (18)E. Control Box Assembly (20)F. Chute Assembly (22)G. Label Location (24)H. Accessories & Packaging (27)2Auxiliary CodesF-1500MAH N-0 October 2003P-0March2004P-1April2004P-2J une2004Q-0J anuary2005R-0December2005 S-0J anuary2007T-0J anuary2008T-1August2008U-0J anuary2009U-1April2009V-0J anuary2010V-1September2010 V-2November2010 A-0J anuary2011A-1November2011 A-2TBDF-1500MWH P-0 January 2004P-1May2004Q-0December2004 R-0J anuary2006S-0March2007T-0April2008T-1August2008U-0February2009U-1September2009 V-1May2010V-3November2010 A-0J anuary2011A-1December2011 A-2TBDF-1500MAH-C P-0 January 2004P-1April2004P-2J une2004Q-0J une2005R-0December2005S-0J anuary2007S-1September2007 T-0J anuary2008T-1August2008U-0J anuary2009U-1November2009 V-0March2010V-1September2010V-2November2010A-0J anuary2011A-1November2011A-2TBDF-1500MWH-C P-0 January 2004P-1May2004Q-0March2005Q-1J uly2005R-0August2006S-0April2007S-1J uly2007T-0February2008U-0February2009U-1May2009V-0J anuary2010V-1J uly2010V-2September2010V-3November2010A-0J anuary2011A-1December2011A-2TBD34Auxiliary Code BreakdownThe auxiliary code is the first two characters in the serial number. The first characterindicates the year. Y ears progress or regress in alphabetical order. The series runs from "A" through "V" and the letters "I" and "O" are skipped. The second character indicates significant part changes within a year. Base is "0" and this number advances for each change. In cases where there is a letter in parentheses, this designates the month. This is the last character in the serial number. The series runs from "(A)" through "(M)" and the letter "(I)" is skipped. This designation is only included when identifying a parts change within an auxiliary code.Note About Ordering PartsMost assemblies cannot be ordered as complete units; parts in the assemblies generally must be ordered separately.F-1500MRH N-0 November 2003 P-0 December 2003 P-1 May 2004 Q-0 J anuary 2005 R-0 December 2005 S-0 J anuary 2007 T -0 March 2008 T -1 September 2008 U-0 February 2009 U-1 May 2009 V-0 J anuary 2010 V-1 J uly 2010 V-2 October 2010 V-3 December 2010 A-0 J anuary 2011 A-1 October 2011 A-2 TBD F-1500MRH-C P-0 January 2004P-1 May 2004 Q-0 April 2005 Q-1 J uly 2005 R-0 December 2005 S-0 J anuary 2007 S-1 J uly 2007 T -0 J anuary 2008 T -1 August 2008 U-0 March 2009 U-1 April 2009 V-1 J une 2010 V-2 September 2010 V-3 November 2010 A-0 J anuary 2011 A-1 October 2011 A-2 TBD5A. Ice Flaker AssemblyF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)N-0 to A-2F-1500MAH(-C)N-0 to V-0F-1500MWH(-C)F-1500MRH(-C)N-0 to V-1F-1500MAH(-C)V-1 and later F-1500MWH(-C)F-1500MRH(-C)V-2 and later8a 891636b1731a 1828a1919a202123222426292728303132333435a352536123a 3456710111213141536a 26aF-1500MWH(-C), F-1500MRH(-C)F-1500MAH(-C) shown1815aTitle: A. Ice Flaker Assembly Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toT-0T-1toU-1V-0V-1V-2toA-1A-2Ice Flaker Assembly Order Assembly Parts Individually Assembly Number for ReferenceOnly F-1500MAH1A0874A011-1A1580A0111-1A1853A0111-1A1853A031 F-1500MAH-C1A0874A021-1A1580A0211-1A1853A0211-1A1853A041 F-1500MWH1A0893A011-1A1582A0111-1A1582A031-1A1844A0111 F-1500MWH-C1A0893A021-1A1582A0211-1A1582A041-1A1844A0211 F-1500MRH1A0878A011-1A1581A0111-1A1581A031-1A1851A0111 F-1500MRH-C1A0878A021-1A1581A0211-1A1581A041-1A1851A02111Socket Head Cap Screw420600-02333333 2Split Lock Washer7L22-1000333333 3Rear Panel F-1500MAH(-C)2A2984G011-3A4956G011111-3A4956G021F-1500MWH(-C)2A3040G011-3A4965G0111-3A4965G02111F-1500MRH(-C)2A3102G011-3A4966G0111-3A4966G02111 3a Hex Head Bolt w/Washer 5×12, SS7B0230512222222 4Junction Box Cover F-1500MAH(-C)F-1500MWH(-C)433410-01111111F-1500MRH(-C)222222 5Ground Screw F-1500MAH(-C)F-1500MWH(-C)433304-02111111F-1500MRH(-C)222222 6Square Washer F-1500MAH(-C)F-1500MWH(-C)433537-02111111F-1500MRH(-C)222222 7Right Side Frame340321G011-3A4849G0111111 8T aper Collar4H0171-01111111 8a Flat Head Screw7C22-04121111116Title: A. Ice Flaker Assembly Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toT-0T-1toU-1V-0V-1V-2toA-1A-29Left Side Frame340324G011-3A4853G0111111 10Front Frame340318-011-3A4852-0111111 11Right Side Panel2A2077G01111111 12Left Side Panel F-1500MAH(-C)2A2201G01111111F-1500MWH(-C)F-1500MRH(-C)2A2076G01111111 13T op Panel2A2074-01111111 14Front Panel F-1500MAH(-C)2A2203-01111111F-1500MWH(-C)F-1500MRH(-C)2A2646-01111111 15Louver F-1500MAH(-C)1A0547-01222222F-1500MWH(-C)F-1500MRH(-C)111111 15a Push Retainer F-1500MAH(-C)4A2414-01666666F-1500MWH(-C)F-1500MRH(-C)333333 16Air Filter F-1500MAH(-C)2A2062G01222222F-1500MWH(-C)F-1500MRH(-C)111111 17Reservoir Bracket 2A2982-01111111 18Gusset3A3305-01222222 19Drain Pan219358G01111111 19a Hex Head Bolt8×127B01-0812222222 20Barrier4A0688-01111111 21Evaporator Strap4A3281-01111111 22Ring431736-01111111 23"O" Ring7616-G09511-4A4755-051111 24Packing327040-01111111 25Lower Spout Strap327041G02111111 26Upper Spout Strap 327042-04111111 26a Wing Nut6, SS7E12-0600222222 27Drip Guide3A1628-01111111 28Spout105378G01111111 28a Thumbscrew415949G11333333 29Actuator F-1500MAH(-C)327038-01111-F-1500MWH(-C)F-1500MRH(-C)1111-30Belt Switch F-1500MAH(-C)440973-01111-F-1500MWH(-C)F-1500MRH(-C)1111-31Switch Cover F-1500MAH(-C)327037-01111-F-1500MWH(-C)F-1500MRH(-C)1111-31a Thumbscrew F-1500MAH(-C)415949G04444-F-1500MWH(-C)F-1500MRH(-C)4444-7Title: A. Ice Flaker Assembly Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toT-0T-1toU-1V-0V-1V-2toA-1A-232Direction Label F-1500MAH(-C)442816-01111-F-1500MWH(-C)F-1500MRH(-C)1111-33Spout Cover F-1500MAH(-C)4A5174-01111F-1500MWH(-C)F-1500MRH(-C)1134Fan Motor Bracket F-1500MWH(-C)F-1500MRH(-C)227639-01111-3A5996-0111135Fan Motor F-1500MWH(-C)F-1500MRH(-C)440917-0111111135a Screw F-1500MWH(-C)F-1500MRH(-C)436863-0133333336Fan Blade F-1500MWH(-C)F-1500MRH(-C)434959-0111111136a Hex Nut F-1500MWH(-C)F-1500MRH(-C)4A1345-0111111136b Washer F-1500MWH(-C)F-1500MRH(-C)435983-0111111189B. Ice Making UnitF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)N-0 to A-28b8a 182a 22b13344a 4b 4c5679101112FlakerCubelet (-C)99a 9b 1010c 10b 10a 10b 10a N-0 to U-1 (L)U-1 (M) and laterTitle: B. Ice Making Unit Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-2Q-0(A-F)Q-0(G)toS-0(F)S-0(G)toU-1(L)U-1(M)toV-1V-2toA-2Ice Making UnitOrder Assembly Parts Individually Assembly Number for ReferenceOnly F-1500MAHF-1500MWHF-1500MRH3A2986A01111111F-1500MAH-CF-1500MWH-CF-1500MRH-C3A2986A021111111Gear Motor (for mountinghardware, see section "A"items 1 and 2)2U0129-011111112Gear Motor Barrier 3A1639-01111111 2a T russ Head Screw4×8, SS7C32-0408222222 2b Flat Plastic Washer7W27-040022222-Rubber Washer4A5268-012 3Spline Coupling420372-01111111 4Housing206509G02111111 4a Hex Bolt8×25, SS7B02-0825666666 4b Washer M8, SS7W22-0800666666 4c Split Lock Washer M8, SS7L22-0800666666 5"O" Ring7616-G0901111-4A4755-0411 6Mechanical Seal432493-01111111 7Auger233811G021-114121G021111-120864G021 8Evaporator2A2200G0111-2A3316G0111-2A3316G0211 8a Socket Head Cap Screw10×20, SS7S12-1020444444 8b Split Lock Washer M10, SS7L22-1000444444 9Extruding Head F-1500MAHF-1500MWHF-1500MRH216407G01111111F-1500MAH-C F-1500MWH-C F-1500MRH-C 2A2202G0111-2A1594G0111119a Seal Bolt M10474757G01333333 9b Washer425277-0133333310Title: B. Ice Making Unit Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-2Q-0(A-F)Q-0(G)toS-0(F)S-0(G)toU-1(L)U-1(M)toV-1V-2toA-210Cutter F-1500MAHF-1500MWHF-1500MRH327026-01222222F-1500MAH-C F-1500MWH-C F-1500MRH-C 4A3070G0211-315736G01111110a Hex Head Bolt F-1500MAHF-1500MWHF-1500MRH10×35, SS7B02-1035111111F-1500MAH-CF-1500MWH-CF-1500MRH-C10×40, SS7B02-104011-10b Split Lock Washer F-1500MAHF-1500MWHF-1500MRH10, SS7L22-1000111111F-1500MAH-CF-1500MWH-CF-1500MRH-C11-10c Washer F-1500MAH-CF-1500MWH-CF-1500MRH-C4A3071-0111-11Dowel Pin F-1500MAHF-1500MWHF-1500MRH713S-0526111111F-1500MAH-CF-1500MWH-CF-1500MRH-C11-12Heater F-1500MAH-CF-1500MWH-CF-1500MRH-C4A4335-01111 13Flange352714-0111C. Refrigeration Circuit F-1500MAH(-C)N-0 to A-214326577a121314111586a9101a 1b 1c2171617aN-0 to V-0V -1a n d l a t e rTitle: C. Refrigeration Circuit Model: F-1500MAH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-1P-2toR-0(L)R-0(M)toT-0T-1toV-0V-1toA-0A-1A-2Refrigeration Circuit Order Assembly Parts Individually Assembly Number for ReferenceOnly 1A0873A0111-1A1201A0111-1A1854A01111Compressor4A1539-0111111-4A1539-031 1a Grommet434922-01444444 1b Spacer434921-01444444 1c Bolt8×45437889-01444444 2High-Pressure Switch433441-051111-463180-0511 3High-Pressure Switch Bracket434938-011111-4Condenser 2A2215-01111111 5Shroud2A2983-01111111 6Fan Motor440911-011-4A3158-0111111 6a Self-Locking Nut NO. 8-327N21I0832444444 7Fan Motor Bracket3A0341-01111111 7a Hex Head Bolt w/Washer5×12, SS7B0230512444444 8Fan Blade4A0197-01111111 9Drier4A1113-01111111 10Drier Bracket445847-01111-11Heat Exchanger3A2978G01111111 12Expansion Valve4A1117-01111111 13Expansion Valve Cover 4A1168-01111111 14Expansion Valve Bulb Holder3A0112-01111111 15Clamp443461-01111111 16Service Valve Bracket3A3968-01111111 17Service Valve4A3420-01222222 17a Hex Head T apping Screw7B03I1412222222C. Refrigeration Circuit F-1500MWH(-C)P-0 to A-24326571213141115891011a 1b 1c24a 4b171617aP-0 to V-1V -2 a n dl a t e rTitle: C. Refrigeration Circuit Model: F-1500MWH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberP-0toR-0(L)R-0(M)toT-0T-1toV-1V-2toA-0A-1A-2Refrigeration Circuit Order Assembly Parts Individually Assembly Number for ReferenceOnly 1A0894A011-1A1203A0111-1A1842A01111Compressor4A1539-011111-4A1539-031 1a Grommet434922-0144444 1b Spacer434921-0144444 1c Bolt8×45437889-0144444 2High-Pressure Switch433441-05111-463180-0511 3High-Pressure Switch Bracket434938-01111-4Condenser HS-01632A2359G0411111 4a Hex Head Bolt w/Washer5×12, SS7B023********* 4b Washer4A0655-0322222 5Drier4A1113-0111111 6Drier Bracket445847-0111-7Heat Exchanger3A3025G0111111 8Water Line T ube A3A3023G0111111 9Water Line T ube B3A3024G0111111 10Water Regulating Valve4A0911-******* 11Male Connector4A1087-0111111 12Expansion Valve4A1117-0111111 13Expansion Valve Cover 4A1168-0111111 14Expansion Valve Bulb Holder3A0112-0111111 15Clamp443461-0111111 16Service Valve Bracket3A3968-0111111 17Service Valve4A3420-0122222 17a Hex Head T apping Screw7B03I141222222Title: C. Refrigeration Circuit Model: F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toR-0(L)R-0(M)toT-0T-1toV-1V-2toA-0A-1A-2Refrigeration Circuit Order Assembly Parts Individually Assembly Number for ReferenceOnly 1A0876A011-1A1202A0111-1A1852A01111Compressor(A-1 and later utilize externalcrankcase heater - item 18)4A1539-021111-4A1539-0311a Grommet434922-0144444 1b Spacer434921-0144444 1c Bolt8×45437889-0144444 2High-Pressure Switch433441-05111-463180-0511 3High-Pressure Switch Bracket434938-01111-4Drier4A1338-0111111 5Drier Bracket453960-0111-6Receiver 437652-0111111 6a Hex Head Bolt w/Washer 5×12, SS7B023********* 7Heat Exchanger3A2995G0111111 8Expansion Valve4A1117-0111111 9Expansion Valve Cover 4A1168-0111111 10Expansion Valve Bulb Holder3A0112-0111111 11Clamp443461-0111111 12Discharge Line Coupling434072-0111111 13Discharge Line T ube Holder438245-0111111 14Liquid Line Coupling426554-0111111 15Liquid Line T ube Holder438246-0111111 16Service Valve Bracket3A3985-0111111 17Service Valve4A3420-0133333 17a Hex Head T apping Screw7B03I141233333 18Crankcase Heater4A5397-011D. Water CircuitF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C) N-0 to A-2213456781112131617181415109Title: D. Water Circuit Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toV-0V-1toA-1A-2Water CircuitOrder Assembly Parts Individually Assembly Number for ReferenceOnly F-1500MAH(-C)2A2997A0111-2A6002A021 F-1500MWH(-C)F-1500MRH(-C)2A2997A011-2A6002A011-2A6002A0211Water Valve Bracket3A0553-0111-3A6392-011 2Water Supply Pipe4A0891G0111-4A0891G021 3Inlet Water Valve4A0865-0111-4A5309-011 4Washer4A0867-01111 5Reservoir Inlet 4A0869-01111 6Reservoir2A0753-01111 7Reservoir Cover214810-01111 8Reservoir Separator4A1255-01111 9Float Switch435490-01111 10Drain Fitting4A0776G01111 11Drain Valve Bracket3A0554-01111 12Drain Valve4A2772-01111 13Water Supply Hose428615-04111 14Silicone Hose L=530mm7730-1822111 15Silicone Hose L=320mm7730I3896111 16Vinyl Hose L=640mm7725-1923111 17Vinyl Hose L=60mm7716-1216111 18Vinyl Hose F-1500MAH(-C)L=330mm7716-202511-F-1500MAH(-C)L=335mm1F-1500MWH(-C)F-1500MRH(-C)L=330mm1-F-1500MWH(-C)F-1500MRH(-C)L=335mm11Hose ClampsHose Clamp4A2017-08333 Hose Clamp4A2017-07111 Hose Clamp4A2017-06111 Hose Clamp4A2017-02222 Hose Clamp4A2017-01333E. Control Box AssemblyF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C) N-0 to A-2Title: E. Control Box Assembly Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-2Q-0toS-0(F)S-0(G)toV-0V-1V-2toA-0A-1A-2Control Box Assembly Order Assembly Parts Individually Assembly Number for ReferenceOnly F-1500MAH(-C)HS-20632A2992A011-2A3410A011-2A4297A011-2A4297A02111 F-1500MWH(-C)F-1500MRH(-C)HS-20642A2991A011-2A3411A011-2A4298A0111-2A4298A02111Water Control Relay406132-03111111 2Spout Control Relay F-1500MAH(-C)406132-06111-F-1500MWH(-C)F-1500MRH(-C)1111-3Gear Motor Protect Relay418271-03111111 4Circuit Protect Relay418271-05111111 5Gear Motor Relay406133-04111111 6Control T ransformer4A0557-******** 7Start Relay (starter)4A1107-13111111 8Start Capacitor 145-174MFD,220VAC3A0076-111111119Run Capacitor30MFD,370VAC3A2005-0311111110Gear Motor Capacitor65MFD,250VAC441021-01111111 11Strap4A2262-03111111 12Control Switch (flush switch)4A0558-******** 13Power Switch4A2332-01111111 14Fuse Holder F-1500MAH(-C)4A0892-01111-4A3449-01111F-1500MWH(-C) F-1500MRH(-C)4A0892-011111-4A3449-011115Control Board Fuse250VAC, 1A4A0893-******** 16Protector F-1500MAH(-C) 440972-011-Fuse Holder4A0892-0211-4A3449-02111Protector F-1500MWH(-C)F-1500MRH(-C)440972-011-Fuse Holder4A0892-02111-4A3449-0211 17Gear Motor Fuse125VAC, 7A4A3804-0111111 18Lamp F-1500MAH(-C)4A2672-01111-F-1500MWH(-C)F-1500MRH(-C)1111-19Control Board Support4A0336-03444444 20Control Board (control timer)437305-01111111 21Cam Timer4A2157-01111111 22Control Box Cover 3A2987-01111111 23Fan Motor Capacitor F-1500MAH(-C)5MFD, 250VAC443192-02111111F. Chute AssemblyF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)N-0 to A-211025a435678911134a11a10a12Title: F. Chute Assembly Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toT-0T-1toA-2Chute AssemblyOrder Assembly Parts IndividuallyAssembly Number for ReferenceOnlyHS-01162A1705A01111Chute216219-0111 2Chute Insulation 216220-0111 3Tie436531G0233 4Chute Baffle A341012G0111 4a Wing Nut M4, SS7E12-040033 5Chute Baffle B341013G0111 5a Wing Nut M4, SS7E12-040033 6Mechanical Bin ControlBracket3A1744G0111 7Actuator436848G0211 8Shaft436851-0111 9Snap Pin715S-000522 10Plate4A2039-0111 10a Thumbscrew415949G1022 11Mechanical Bin ControlProximity Switch4A2033-0111 11a Thumbscrew415949G0822 12T russ Head Screw (ground)4×8, SS7C32-040811 13Packing441217-011-G. Label LocationF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)N-0 to A-2F-1500MAH(-C), F-1500MWH(-C)F-1500MRH(-C)Title: G. Label Location Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-2Q-0toS-0(B-F)S-0(G)toT-0T-1toV-0V-1V-2toA-2Label LocationOrder Assembly Parts Individually Assembly Number for ReferenceOnly F-1500MAH2A2998A011-2A2998A07111-2A6127A0111 F-1500MAH-C2A2998A041-2A2998A10111-2A6127A0411 F-1500MWH2A2998A031-2A2998A091111-2A6127A031 F-1500MWH-C2A2998A061-2A2998A121111-2A6127A061 F-1500MRH2A2998A021-2A2998A081111-2A6127A021 F-1500MRH-C2A2998A051-2A2998A111111-2A6127A0511Instruction Sheet F-1500MAH(-C)2A3011-011111-F-1500MWH(-C)F-1500MRH(-C)11111-2Emblem 4A0560-01111111 3Penguin Label 4A0526-01111111 4Rating Label F-1500MAH2A3002-01111111F-1500MAH-C2A3002-04111111F-1500MWH2A3002-03111111F-1500MWH-C2A3002-06111111F-1500MRH2A3002-02111111F-1500MRH-C2A3002-05111111 5Air Filter Label 426177-01111111 6Instruction Label326371-01111111 7Cleaning Label 216557-011-2A3443-0111111 8Nameplate F-1500MAH2A3001-01111111F-1500MAH-C2A3001-04111111F-1500MWH2A3001-03111111F-1500MWH-C2A3001-06111111F-1500MRH2A3001-02111111F-1500MRH-C2A3001-05111111 9Warning T ag: ElectricalConnection428430-01111111 10Control Label F-1500MAH(-C) 4A3285-011-4A3805-01111-4A5182-0111F-1500MWH(-C) F-1500MRH(-C)4A3285-011-4A3805-011111-4A5182-011Title: G. Label Location Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toP-2Q-0toS-0(B-F)S-0(G)toT-0T-1toV-0V-1V-2toA-211R404A Label4A0960-01111111 12Caution Label E439145-01111111 13Wiring Label F-1500MAH(-C) 3A2991-011-3A3519-011-3A4495-0111-3A6114-0111F-1500MWH(-C) F-1500MRH(-C)3A2991-011-3A3519-011-3A4495-01111-3A6114-01114Instruction Sheet454301-01111-15Caution Label H439148-01111111 16T ag: Fan Motor Leads F-1500MRHF-1500MRH-C4A1494-0111111117Caution Remote Label F-1500MRHF-1500MRH-C4A1491-0111111118Caution 404A T ape F-1500MRHF-1500MRH-CL=250mm4A1535L01111-19Gear Motor Fuse Label4A4278-0111111H. Accessories & PackagingF-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)N-0 to A-2Title: H. Accessories & Packaging Model: F-1500MAH(-C), F-1500MWH(-C), F-1500MRH(-C)IndexNo.Description Material orModel Number Part NumberRequired NumberN-0toA-21Instruction Manual91A2OA10B1 2Universal Brace4A0363-012 2a Hex Head Bolt5×12, SS7B02-05122Packaging1A0531A111。

阿里安洗衣机安装 操作 维护手册说明书

阿里安洗衣机安装 操作 维护手册说明书

©2019 年 Alliance Laundry Systems LLC,版权所有 保留所有权利。未经出版商明确书面授权,不得以任何形式或方式复制或传输本手册的任何部分或内容。
适合滚筒烘干机使用的具体类型。详情参考关于排气系统连接的部分。柔性排气材料会皱缩,易被压碎,堆积棉绒。 这些特点会阻碍滚筒烘干机中的空气流通,增加发生火灾的风险。
W752R1
以下信息适用于美国马萨诸塞州。 • 该电器只能由马萨诸塞州的持证水暖工或煤气设备安装工进行安装。 • 本设备必须使用 91 厘米 [36 英寸]长的气体用软接头进行安装。 • T 型手柄的燃气截止阀必须安装在本设备的供气管道上。 • 本设备不得安装在卧室或浴室中。
安全信息...............................................................................................12 安全提示说明.............................................................................................. 12 重要安全说明.............................................................................................. 12
警告
为了您的安全,请务必遵守本手册中规定的信息以最大程度减少发生火灾、爆炸的发生或避免财产损失、人身伤害或死 亡。
W033
警告
• 请勿将在本设备或任何其他设备附近存放或使用汽油或其他易燃气体和液体。 • 闻到燃气味时的处理方法:
• 请勿尝试开启任何设备。 • 请勿触摸任何电器开关;请勿在您所在的建筑物内使用电话。 • 疏散所有人员离开房间、建筑物或所在区域。 • 立即使用邻居的电话联系您的燃气供应商。遵循燃气供应商的操作指示。 • 如果您无法联系燃气供应商,请呼叫消防队。 • 本设备必须由合格的安装人员、服务机构或燃气供应商进行安装及维修。

ES102用户手册说明书

ES102用户手册说明书

ES102 user manual Suzhou eSkywireless Inc.Information to UserThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by relocating the receiving antenna or consulting the dealer or an experienced radio/TV technician for help.Mobile RF WarningThis equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.Changes and Modification Warning StatementAny Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.1 PREPARE before INSATLLATION1.1 Product Display(image of ES102)(wire harness of ES102)1.2Packaging InspectionOpen the box, check the terminal model is correct and the accessories are complete. Otherwise, please contact your dealer.1.3Install SIM Card1.3.1Selection of SIM CardThe ES102 is a GPS/GPRS terminal, and it needs a GSM/GPRS SIM card. please reference dealer’s opinion to select carrier.1.3.2Installation SIM cardOpen the terminal cover, and put the metal side of SIM card face down and then fasten the card slot cover.1.4Power OnThe terminal standard power supply is 6V-34V. the red line is the positive power supply and the black line is the negative power supply.Note:Please select the negative power line grounding alone.2 Steps of AT Setting before testsStart hyper-terminal connection as follows.1)select the comm port of PC through which ES102 is connected with PC, as the follows2) In Port Settings, change communication speed (bits per second) to 115200bps,3)Final step is the certain AT settings necessary after 1st running of downloaded program.3.1) Start connection first3.2) Restart ES1023.3) After you see the "IIII"as the following picture, start setting.3 INSTALL and OPERATION3.1 Installation MethodThe terminal is GPS positioning products, it is recommended that you follow the instructions to install.Note:1) The following installation order, please do not inverted.2) During the installation process, please do not supply the terminal.The terminal installation is divided into hidden installation and open installation.When the terminal is using special vehicles, hidden installation is recommended. Otherwise, open installation is chosen. (To avoid thieves’ damage, the installation location should be hidden)(cigarette lighter)(OBD)①Battery connector②Power connector, connecting terminal with the power connector of wire harness, as picture above.③I/O connector, connecting terminal with the I/O connector of wire harness, as picture above.④I/O lines⑤Power lines, it can connect with cigarette lighter or OBD, as picture above.3.1.1 Open InstallationThe power connecting line we selected is provided by original cigarette lighter cord.3.1.2 Hidden installationThe power connecting line we selected is provided by original the main power core. And the red line has a fuse box (3A fuse) which can play a short circuit overcurrent protection role.3.2Installation SiteThe places that we suggest to install:①The bottom of the front windshield decorative plates②Around of front dashboard (epidermis as nonmetallic material)③Below the decorative panels of rear windshield④Inside the front bumper (should pay attention of water)⑤Below the wipers plate (should pay attention of water)3.3 Installation Notes① Avoid put together with the emission source, for example, reversing radar, anti-theft devices and other on-board communications equipment.② As for fixing the terminal, you can bound with ties or stick with wide sponge strength double-faced adhesive.③ The terminal has GSM antenna and GPS antenna,so the installation should ensure that the ES102face up (that is GPS toward the sky). Besides, there is no on-metallic object that obscures above the terminal.④If your car’s windshield pasted with metal insul ation layer or the heating layer, GPS receiving signal will be weakened, and it may cause GPS work abnormal. So please change the location you installed the terminal.。

URC高性能柔性乙酯乙酚防腐蚀膜说明书

URC高性能柔性乙酯乙酚防腐蚀膜说明书

PROVISIONAL TDS URCHigh Performance Urethane CoatingURC is a transparent, flexible, modified high performance urethane conformal coating, specifically designed for the protection of electronic circuitry. URC has excellent mechanical and dielectric properties after temperature cycling.∙Wide operating temperature range; excellent performance in changeable temperatures∙Resistant to a wide variety of chemicals; improved by heat curing∙Excellent mechanical properties, including abrasion resistance∙Excellent electrical properties and low temperature performanceApprovals RoHS-2 Compliant (2011/65/EU): YesREACH Compliant: YesIPC-CC-830: Meets ApprovalMIL-I-46058C: Meets ApprovalLiquid Properties Appearance: Clear yellow/brown liquidDensity @ 20°C: 0.90 g/ml (Bulk), 0.84 g/ml (Aerosol)Flash Point: >90⁰CSolids content: 43% (Bulk), 21.5% (Aerosol)VOC Content: 57% (Bulk), 93% (Aerosol)Viscosity @ 20°C: 240mPa sTouch Dry Time at 20°C: 15 minutesRecommended Drying Time: 24 Hours @ 20°C or4 Hours at 60⁰C or2 Hours at 90⁰CCoverage @ 25µm: 17m2Dry Film Coating Colour: ClearTemperature Range: -40 to +140⁰CFlammability: Meets UL94 V-0Moisture Resistance: Meets MIL-I-46058CSalt Spray Resistance: Meets ASTM B117-03Dielectric Strength: 80 kV/mmSurface Insulation Resistance: 1 x 1016ΩDissipation Factor: 0.001Dielectric Constant: 2.7Packaging Description Order Code Shelf LifeURC Conformal Coating 5 Litre Bulk200ml AerosolURC05LURC200D24 Months12 MonthsLow Odour Thinners 5 Litre Bulk LOT05L24 Months Removal Solvent 1 Litre Bulk CCRG01L 36 Months Directions for UseURC can be sprayed, dipped or brushed. The thickness of the coating depends on the method of application (typically 25-75 microns). Temperatures of less than 16°C or relative humidity in excess of 75% are unsuitable for the application of URC. As is the case for all solvent based conformal coatings, adequate extraction should be used (refer to MSDS for further information). Substrates should be thoroughly cleaned before coating. This is required to ensure that satisfactory adhesion to the substrate is achieved. Also, all flux residues must be removed as they may become corrosive if left on the PCB. Electrolube manufacture a range of cleaning products using both hydrocarbon solvent and aqueous technology. Electrolube cleaning products produce results within Military specification.Spraying – BulkURC is suitable both for use in manual spray guns and selective coating equipment. If bulk coating material has been agitated, allow to stand until air bubbles have dispersed. The selected nozzle should enable a suitable even spray to be applied in addition to suiting the prevailing viscosity. The normal spray gun pressure required is 274 to 413 kPa (40 ~ 60 lbs/sq.inch). After spraying, the boards should be placed in an air-circulating drying cabinet and left to dry.Dip CoatingEnsure that the coating material in the container has been agitated thoroughly and has been allowed to stand for at least 2 hours for all the air bubbles to disperse. The board assemblies should be immersed in the URC dipping tank in the vertical position, or at an angle as close to the vertical as possible. Connectors should not be immersed in the liquid unless they are very carefully masked. Electrolube Peelable Coating Mask (PCM) is ideal for this application. Leave submerged for approximately 10 seconds until the air bubbles have dispersed. The board or boards should then be withdrawn slowly (1 to 2 mm / seconds) so that an even film covers the surface. After withdrawing, the boards should be left to drain over the tank or drip tray until the majority of residual coating has left the surface. After the draining operation is complete, the boards should be placed in an air-circulating drying cabinet and left to dry.BrushingEnsure that the coating material has been agitated thoroughly and has been allowed to settle for at least 2 hours. The coating should be kept at ambient temperature. When the brushing operation is complete the boards should be placed in an air-circulating drying cabinet and left to dry.I nspectionURC contains a UV trace, which allows inspection of the PCB after coating to ensure complete and even coverage. The stronger the reflected UV light, the thicker the coating layer is.Revision 2: May 2017。

X2Y 过滤器和耦合电容器说明书

X2Y 过滤器和耦合电容器说明书

216• Replace up to 7 components with one X2Y• Differential and common mode attenuation• Matched capacitance line to ground, both lines• Low inductance due to cancellation effect • High Speed Data Filtering • EMC I/O Filtering• FPGA / ASIC / µ-P Decoupling • DDR Memory DecouplingX2Y ® technology patents and registered trademark under license from X2Y ATTENUATORS, LLCH OW TO O RDER X2Y ® F ILTER & D ECOUPLING C APACITORSP/N written: 100X14W104MV4TDimensional View Cross-sectional ViewA B Equivalent CircuitsT10.0Ω1.00Ω0.10Ω0.01ΩA p p r o x i m a t e I m p e d a n c e (Ω)10.0Ω1.00Ω0.10Ω0.01ΩA p p r o x i m a t e I m p e d a n c e (Ω)M ECHANICAL C HARACTERISTICS0402 (X07)0603 (X14)0805 (X15)1206 (X18)1210 (X41)1410 (X44)1812 (X43)IN mmIN mm IN mm IN mm IN mm IN mm IN mm L 0.045 ± 0.003 1.143 ± 0.0760.064 ± 0.005 1.626 ± 0.1270.080 ± 0.008 2.032 ± 0.2030.124 ± 0.010 3.150 ± 0.2540.125 ± 0.010 3.175 ± 0.2540.140 ± 0.010 3.556 ± 0.2540.174 ± 0.010 4.420 ± 0.254W 0.025 ± 0.0030.635 ± 0.0760.035 ± 0.0050.889 ± 0.1270.050 ± 0.008 1.270 ± 0.2030.063 ± 0.010 1.600 ± 0.2540.098 ± 0.010 2.489 ± 0.2540.098 ± 0.010 2.490 ± 0.2540.125 ± 0.010 3.175 ± 0.254T 0.020 max 0.508 max0.026 max 0.660 max 0.040 max 1.016 max 0.050 max 1.270 max 0.070 max 1.778 max 0.070 max 1.778 max 0.090 max 2.286 max EB 0.008 ± 0.0030.203 ± 0.0760.010 ± 0.0060.254 ± 0.1520.012 ± 0.0080.305 ± 0.2030.016 ± 0.0100.406 ± 0.2540.018 ± 0.0100.457 ± 0.2540.018 ± 0.0100.457 ± 0.2540.022 ± 0.0120.559 ± 0.305CB 0.012 ± 0.0030.305 ± 0.0760.018 ± 0.0040.457 ± 0.1020.022 ± 0.0050.559 ± 0.1270.040 ± 0.005 1.016 ± 0.1270.045 ± 0.005 1.143 ± 0.1270.045 ± 0.005 1.143 ± 0.1270.045 ± 0.005 1.143 ± 0.127Amplifier Input Filter ExampleIn this example, a single Johanson X2Y ® component was used to filter noise at the input of a DCinstrumentation amplifier. This reduced component count by 3-to-1 and costs by over 70% vs.conventional filter components that included 1% film Y-capacitors.Source: Analog Devices, “A Designer’s Guide to Instrumentation Amplifiers (2nd Edition)” by Charles Kitchin and Lew CountsX2Y ® Circuit 1: Filtering Circuit 1 connects the X2Y ® filter capacitor across two signal lines. Common-mode noise is filtered to ground (or reference) by the two Y-capacitors, A & B. Because X2Y ® is a balanced circuit that is tightly matched in both phase and magnitude with respect to ground, common-to-differential mode noise conversion is minimized and any differential-mode noise is cancelled within the device. The low inductance of the capacitors extends their highfrequency attenuation considerably over discrete MLCs.X2Y ® Circuit 2: Power Bypass / Decoupling Circuit 2 connects the A & B capacitors in parallel doubling the total capacitance while reducing the inductance. X2Y capacitors exhibit up to 1/10th the device inductance and 1/5th the mounted inductance of similar sized MLC capcitors enabling high-performance bypass networks with far fewer components and vias. Low ESL deliversimproved High Frequency performance into the GHz range.PowerGroundGSM RFI Attenuation in Audio & AnalogGSM handsets transmit in the 850 and 1850 MHz bands using a TDMA pulserate of 217Hz. These signals cause the GSM buzz heard in a wide range ofaudio products from headphones to concert hall PA systems or “silent” signalerrors created in medical, industrial process control, and security applications.Testing was conducted where an 840MHz GSM handset signal was deliveredto the inputs of three different amplifier test circuit configurations shown belowwhose outputs were measured on a HF spectrum analyzer.1) No input filter, 2 discrete MLC 100nF power bypass caps.2) 2 discrete MLC 1nF input filter, 2 discrete MLC 100nF power bypass caps.3) A single X2Y 1nF input filter, a single X2Y 100nF power bypass cap.X2Y configuration provided a nearly flat response above the ambient and up to 10 dB imrpoved rejection than the conventional MLCC configuration.X2Y High Performance Power Bypass - Improve Performance, Reduce Space & ViasActual measured performance of two high performance SerDes FPGA designs demonstrate how a 13 component X2Y bypass network significantly out performs a 38 component MLC network. For more information see /pdfs/JDI_X2Y_STXII.pdfCommon Mode Choke9.0 x 6.0 x 5.0 mm X2Y ®2.0 x 1.3 x 1.0 mmAmbientEliminating Capacitor Anti-Resonance IssueA common design practice is to parallel decade capacitance values to extend the high frequency performance of the filter network. This causes an unintendeand often over-looked effect of anti-resonant peaks in the filter networkscombined impedance. X2Y’s very low mounted inductance allows designersto use a single, higher value part and completely avoid the anti-resonance problem. The impedance graph on right shows the combined mountedimpedance of a 1nF , 10nF & 100nF 0402 MLC in parrallel in RED. The MLCnetworks anti-resonance peaks are nearly 10 times the desired impedance. A100nF and 47nF X2Y are plotted in BLUE and GREEN. (The total capacitance ofX2Y (Circuit 2) is twice the value, or 200nF and 98nF in this example.) The sigleX2Y is clearly superior to the three paralleled MLCs.Use of solder mask beneath component is not recommended because of flux/contaminant entrapment.Recommended X2YBypass LayoutO PTIMIZING X2Y P ERFORMANCE ON THE PCBX2Y capacitors deliver excellent performance in EMI/RFI fi ltering and Power Bypass applications. Physical and electrical placement on the PCB is critical in achieving good results. A low inductance, dual ground connection is mandatory.EMI Filter Applications Low inductance PCB routing examples are shown in fi gures 1 and 2. Figures 3-5 show unbalanced and high inductance connections and should be avoided. See detailed application note X2Y EMI FIlter Evaluation and PCB Design Guidelines .Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5PDN / Power Bypass Applications Figures on right compare the X2Yrecommended layout against a poor layout. Because of its long extents fromdevice terminals to vias, and the wide via separation, the poor layout exhibitsapproximately 200% L1 inductance, and 150% L2 inductance compared torecommended X2Y layouts. See detailed application note X2Y Power BypassMounting.L AB E VALUATION S OLDERING P RECAUTIONSCeramic capacitors (X2Y and standard MLC types) can be easily damaged when hand soldered. Thermal cracking of the ceramicbody is often invisible even under a microscope. Factors that increase thermal cracking risk:1. 4 terminals to solder can increase hand-soldering time and temperature exposure2. Pb-free solders have higher reflow temperatures3. Low inductance connections to ground are inherently good heat-sinksA damaged component may exhibit a short circuit immediately and not recover, or may operate with intermittent Insulation Resistance(IR) levels. If you are not achieving expected results and have followed the other guidelines carefully, check to see you are adhering tothe soldering guidelines below:• Always pre-heat the PCB and component to within 50°C of solder reflow temperature at 2°C/sec. maximum.• Use contact-less hand solder tools such as a hot air pencil, IR lamp, etc.• Avoid over-heating of the ceramic component, temperature limit: 260°C for 20-30 seconds max.• Use a soldering iron as last resort; 20W max. tip, NO CONTACT with ceramic, limit solder time to 5 seconds max.A reliable, cost effective prototype PCB reflow soldering process is possible using a household toaster oven. There are several goodprocedures available on-line by googling “Toaster Oven Soldering”Parts listed in the table are standard parts and carry the highest DC voltage rating for their size and value. Legacy part number requirements for lower voltage codes are fulfilled with the higher voltage rating which exceeds the requirement. Please contact the factory for part values or voltage combinations that are not shown.Parts listed in the table are standard parts and carry the highest DC voltage rating for their size and value.Legacy part number requirements for lower voltage codes are fulfilled with the higher voltage rating which exceeds the requirement.Please contact the factory for part values or voltage combinations that are not shown.15191 Bledsoe Street Sylmar, California 91342 T el (818) 364-9800 • FAX (818) 364-6100JOHANSON HONG KONG LTD.Unit E, 11/F ., Phase 1, Kaiser Estate41 Man Yue StreetHunghom, Kowloon, Hong KongJOHANSON EUROPE LTD.Acorn House, Old Kiln Road Flackwell Heath, Bucks HP10 9NR United Kingdom Johanson Dielectrics, Inc. reserves the right to make design and price changes without notice. All sales are subject to the terms and conditions printed on the back side of our sales order acknowledgment forms, including a limited warranty and remedies for non-conforming goods or defective goods. We will be pleased to provide a copy of these terms and conditions for your review .。

ESAB Cutting Systems Ultrarex UXB 坐标气焰切割机说明书

ESAB Cutting Systems Ultrarex UXB 坐标气焰切割机说明书

ESAB CUTTING SYSTEMS ULTRAREX UXBGas Cu tt ing MachineWith Photoelectric TracingULTRAREX UXBCo-ordinateGas Cutting Machine With Photoelectric TracingThe ULTRAREX UXB is a co-ordinate gas cutting machines with photo-electric con- trol. This machine has been specifically developed for use in small and medium sized workshops of the steel fabrication industry.Precise guiding accuracy, optimum cutting speed, easy mounting and serviceability, low prime costs, these are only someof the most remarkable features of the ULTRAREX UXB.The machine has been designed in com- pliance with the latest ergonomic guide- lines. The machine meets the regulations of the Employer's liability insurance association and those of the VDE (German Electrical Standards), and of course, it is in accordance with the German specifications applicable to gas cutting machines.The ULTRAREX UXB is equipped with a robust co-ordinate drive and a tracer control system which is approved since many years.Integrated circuits in C-MOS technology guarantee a maximumtracer drawings or silhouettesto the machine cutting torches.No tracer drawings are required for straight line cutting or rectangular bevel- ling of plates. Cutting in all four co- ordinate directions is simply carried out by operating a selector switch on the control head.A gangway of approx.400can be equipped with up to 4 machine cutting torches, thus making it suitable either for one-off or batch production. Machine carriageThe machine carriage includes a carriagefor the longitudinal motion on the track,and a transverse carriage moving, on themain beam fo the longitudinal carriage.The longitudinal carriage is a triangulateddesign, and is equipped with hardened,adjustable running wheels and guiderollers with ball bearings. This guaranteessmooth running and optimum guidingaccuracy in longitudinal direction.The transverse carriage, equipped with arack is used for the simultaneous motionof the torch carriages and the photo-electric control head.Machine trackThe machine track include's two rails,hereof one guiding and one support rail.The track can be optionally fixed to4 independent rail columns or to 2 railstands arranged at right angles to themachine track.The track is available in standard lengthsof 3000 mm and 4000 mm. Only the4000 mm track can be extended with2000 mm extension track.Tracing tableThe tracing table is used to carry tracerdrawings. It is movable between themachine rails. It surface is paintedfor the sizes 15 and 15/20.Kerf compensationThe kerf compensation allowing an adjust-ment of the kerf width up to mm,enables the automatic correction ot tracerdrawings. The required kerf compensationis set on the scale ring of the controlhead. It is, therefore, not necessary tomake allowances for the kerf width whenpreparing tracer drawings.Co-ordinate controlThe movement of the machine carriageboth in longitudinal and transversedirection is effected by two separateddrive units. Pinions transmit the torque ofthe electro-motors via gears to the pinionmounted on the rear track wheel for thelongitudinal motion, and to the rackmounted on the transverse carriage forthe transverse motion.A freewheel mechanical clutch allowseasy and accurate positioning of themachine by hand.Photo-electric tracing(scale 1 : 1)The photo-electric control head in serieslocated on the left-hand side, can bemoved and locked on the transversecarriage.It is equipped with a control panel com-prising all operating units and switchesnecessary for the control and trancing.The movement of the control head istransmitted to the torch carriages viatransverse carriage.The photo-electric tracer controlenables tracing from line drawings(min. line thickness0.8Photo -electric control head with integrated control units Torch carriage with manual height control Torch carriage with motorized height control and electric ignitiondeviceis adjusted by means of electromotor gen and cutting oxygen.drive which is manually operated by a tumbler switch on the additional oper - ator's panel.Distance of motorized height control is 245 mm in vertical direction.The main cutting oxygen valve allows the proportional supply of the cutting oxygen necessary when piercing holes.A later settlement from manual to motorized height control is possible.Central solenoid valve forb y means of a rotaryswitch located on the control head. The cutting speed remains constant for all directions of the machine motion. Torch carriagewith manual height controlThe torch carriage is equipped with running wheels; it is locked by means of a clamping device to the transverse carriage so that there is a firm connection between the con - trol head and the torch carriage.An adjustable longitudinal support enables easy adjustment of the machine cutting torches to the plate edge.The machine cutting torch itself can be swivelled up to in transverse direc - tion and adjustable up to 15' in longi - tudinal direction.It also can be adjusted in vertical direction up to 250 mm by means of a rack and pinion.Additional operating panel for motorized 2 stagepressure regulatorThis station is used for setting the gas pressures and can be wall mounted.It consists of pressure regulators, ball valves, flash back arrestors and console. Self assemblyThe erection of the machine is quite simple and can be managed by the cus- tomer according to our detailed mounting instructions.2x ma Z)x416 #K)a109Z bl a e o t l m1m i1r s o)8Q1m1m1004a-l a c r9-78 76(01264) 332233Fax: (01 264)332074。

ESAB LHF 400 高功率阴极直流铣刀说明书

ESAB LHF 400 高功率阴极直流铣刀说明书

LHF 400Heavy duty rectifierRobust and powerfulThe LHF 400 is a sturdy and robust thyristor-controlled unit intended for manual heavy duty MMA welding with covered electrodes with direct current.LHF 400 can also be used for TIG welding together with g g a TIGAID 315 AC/DC.The LHF 400 is recommended especially for the highest requirements and toughest areas of applications. The large wheels makes it easy to move.Well proven technology together with ESAB developed software provides high reliability and outstanding welding performance.Easy to useThe wide current and voltage range make it easy to optimise settings for a wide variety of filler materials. It is possible to adjust parameters during the welding process.The LHF units are equipped with such functions as hot start and anti stick.Applications•General fabrication and civil construction•Repair and maintenance •Power generation g •Pipelines•Shipbuilding and offshore •Process industryXA00068720FlexibilityThe units have vertical static characteristics which means that regardless of cable length and arc voltage, the current is constant.The dynamic characteristics of the LHF machines ensures stable, spatterfree arc and easily controlled molten pool.Due to high power factor energy consumption is low as g p gy p well as installation costs.As an option the LHF range can be equipped with remote control units.The units are switched off automatically in case of overheating.•Outstanding welding characteristics-high efficiency d hi h lit ldi and high quality welding.•Wide current and voltage range-multiple purpose applications.•Mains voltage compensation -stable welding controls•Stepless current control -exact settings and giving remote control facilities A ti ti k d h t t t•Anti stick and hot startTechnical dataLHF 400Mainsvoltage 400/415/500V 350Hz Mains voltage400/415/500 V, 3~50 Hz 440-460/550 V, 3~60 Hz Permitted load at 35% duty cycle 400 A 60% duty cycle 315 A 100% duty cycle 250 ASetting range (DC)8 A/20V -400 A/36V Open circuit voltage 80-87 V Open circuit power340W Power factor at maximum current 0,9Efficiency at maximum current 74%Inductance outlets 2Dimensions lxwxh 1310x 765 x 705 mm Weight195 kgOperating temperature -10 till +40°C Enclosure classIP 23Application classificationSOrdering informationLHF 4000319 783 882LHF 400 Stationary0319 783 885AccessoriesMMA 1 Remote control, 10 m 0349 501 024MMA 2 Remote control, 10 m 0349 501 025AT1 Remote control0459 491 896AT1 CoarseFine Remote control0459 491 897Connection cable 5 m analogue 12 pole 0459 552 880Connection cable 10 m analogue 12 pole 0459 552 881Connection cable 15 m analogue 12 pole 0459 552 882Connection cable 25 m analogue 12 pole 0459 552 883A ili t f (f TIG d d i )0320003880Auxiliary transformer (for TIG or rod drier)0320 003 880Spacer bars (stationary)0320 000 880Pneumatic tyres 0320 001 8804-wheel chassis0320 002 880Protective 2-wheel frame0365 053 880ESAB AB Box 8004SE-402 77 GÖTEBORG SWEDEPhone: +46 31 50 90 00 Fax +4E-mail:************Quality accessories for the quality welderESAB offers a wide range of accessories. The complete range, along with product information, is available at our local web-sites, look at or contact your local ESAB dealer.U i ll d i d tUnrivalled service and support Our commitment and ability to deliver the expected service and support starts immediately after the order is confirmed. We endeavour to offer our customers an After Sales service, which is second to non. A strong and skilful service organisation is prepared to offer service and maintenance, calibration, validation and upgrading of equipment and software. The service organisation will offer standardised solutions for the reconditioning or modification of existing products.Spare and wear parts are manufactured according to ESAB’s quality plan. Exchange Printed Circuit Board (PCB), exchange modules and components are available for all our products in order to reduce downtime to an absolute minimum. ESAB is continuously upgrading authorised service partners for local service support. Customers who have their own service and maintenance personnel will always be offered a service-training package as part of a total ESAB offering. However, product and process training for end-users will form an additional part of the ESAB offering.Always ask your ESAB sales i o n s w i t h o u t p r i o r n o t i c eof the ESAB offering. Always ask your ESAB salesrepresentative or distributor for a complete ESAB solution.v e s t h e r i g h t t o a l t e r s p e c i f i c a t 2009-09-11 / E S A B r e s e r EN 6 31 22 04 49。

re102安规电容

re102安规电容

re102安规电容RE102是电磁兼容性测试的一个标准,其着重规定了军用设备在电磁辐射方面的要求。

在军用设备中,电容器是一种常见的元器件,其中RE102安规电容是指符合RE102标准的电容器。

本文将对RE102安规电容的特点、应用、测试要求等进行详细介绍。

RE102安规电容具有以下特点。

RE102安规电容在军用设备中有着重要的应用。

首先,它常被用于军用通信设备中,用于抑制高频噪声,确保通信质量。

其次,RE102安规电容还可以用于雷达系统中,用于减少电磁辐射对雷达信号的干扰。

此外,RE102安规电容还常被应用于导航系统、飞行控制系统等军用设备中,以保证设备的正常工作。

RE102安规电容的测试要求十分严格。

根据RE102标准的要求,RE102安规电容需要经过模拟辐射测试和传导辐射测试。

模拟辐射测试主要是测试电容器在电磁场辐射下的工作情况,而传导辐射测试则是测试电容器在电磁场辐射下的散射与耦合情况。

测试的目的是确保RE102安规电容能够在电磁辐射环境下正常工作,不对周围设备产生干扰。

为了满足RE102标准的要求,制造RE102安规电容的厂商需要严格控制生产过程。

首先,要选用高质量的材料,以保证电容器的稳定性和可靠性。

其次,要在生产过程中进行严格的质量控制,确保每一个电容器都符合规定的电性能参数和物理性能参数。

最后,还需要对生产的RE102安规电容进行全面的测试,以确保其符合RE102标准的要求。

总体而言,RE102安规电容作为一种符合RE102标准的电容器,在军用设备中具有重要的应用。

它能够有效地抑制电磁辐射,提高设备的电磁兼容性。

同时,RE102安规电容还具备体积小、重量轻、安装方便等特点,使得其在军用设备中得到广泛应用。

为了确保RE102安规电容的质量和可靠性,制造厂商需要严格控制生产过程,并进行全面的测试。

通过这些措施,RE102安规电容能够满足军用设备对电磁兼容性的要求,为军事应用提供可靠的支持。

Bosch 可畜牧布料Sensor PIR102白皮书说明书

Bosch 可畜牧布料Sensor PIR102白皮书说明书

1
Receiver Range: 300 m (984 ft) Recommended: 100 m (300 ft)
Specifications
6.5 ft. (2 m)
Mount the detector 2 m (6.5 ft) above the floor.
General - Dimensions (HxWxD): 11.2 cm x 6.5 cm x 4.4 cm
13 ft minutes have passed since the previous alarm
the pattern boundaries.Although gener-
Do not mount the magnet flush with the wall. A small amount of adhesive is rcommended to keep the magnet in
place.
4 Leveling
Circuit Board Mounting Brackets
NOTICE: Do not twist.
© 2012 Bosch Security Systems, Inc.
c) In non-pet applications only, if look-down is desired, peel away the lookdown mask. Do not remove the clear plastic lens.
2m
7 ftห้องสมุดไป่ตู้
alarms. After setup and tests are completed, and there has been no activity in the sensor’s

fr102参数

fr102参数

FR102参数
FR102是一款高效、可靠的开关设备,广泛应用于各种需要快速切换的场合。

它具有一系列出色的参数,确保了其在各种应用中的稳定性和可靠性。

首先,FR102的开关速度非常快,可以在极短的时间内完成切换操作。

这使得它在需要快速响应的应用中表现出色,如电机控制、电源供应等。

其次,FR102具有很高的耐压能力。

这使得它能够在高电压或高电流的环境下工作,而不会发生击穿或短路。

这大大提高了FR102的使用寿命和安全性。

此外,FR102还具有良好的隔离性能。

它采用先进的绝缘材料和结构设计,能够在各种温度和湿度条件下保持可靠的隔离效果。

这不仅保证了设备的安全运行,同时也减少了故障和维修的需要。

另外,FR102的体积小巧,易于安装和集成。

这使得它在空间有限的环境中也能得到广泛应用。

同时,FR102还具有多种不同的规格和型号,以满足不同应用的需求。

总的来说,FR102的参数表现出色,使得它成为一种高效、可靠、安全的开关设备。

无论是在工业自动化、电力供应、还是家电控制等领域,FR102都能发挥出色的性能,为各种应用提供稳定、可靠的开关解决方案。

S120常用参数之欧阳数创编

S120常用参数之欧阳数创编

S120常用控制参数1.2.访问权限及出厂复位P003 BOP访问级别3:专家4:维修P010 驱动调试参数筛选 0:就绪1:快速调试2:功率单元调试3:电机调试(电机模块)4:编码器调试(电机模块)5:工艺应用/单元15:数据组30:参数复位P970 驱动参数复位 0:当前无效1:复位参数5:复位Safety参数(电机模块)100:复位BICO参数3.电机数据组P4.编码器P5.实际信号及控制字和状态字P015 宏文件选择r019 BOP控制字状态r020 转速设定值 rpmr021 转速实际值 rpmr022 转速实际值 rpmr024 滤波的输出频率 Hzr025 已滤波的输出电压 Vr026 已滤波的直流母线电压 Vr027 已滤波的电流实际值 Ar031 已滤波的转矩实际值 Nmr035 端子上输入的温度℃(BLM)/电机温度(电机模块)r037 功率单元温度℃/控制单元温度℃r046 缺少的使能信号r050 命令数据组有效位00:CDS 0 有效位01:CDS 1 有效r051 驱动数据组有效位00:DDS 0 有效位01:DDS 1 有效状态字 1 位00:接通就绪=r0899.0位01:运行就绪=r0899.1位02:运行使能=r0899.2位03:故障有效=r2139.3位04:OFF2有效=r0899.4位05:OFF3有效=r0899.5位06:接通禁止有效=r0899.6位07:警告有效=r2139.7位08:设定值/实际值偏差 =r2197.7位09:PLC控制请求=r0899.9位10:达到或超过n比较值 =r2199.1位11:达到转矩极限=r1407.7(取反)位12:电机抱闸打开=r0899.12位13:电机超温报警=r2135.14(取反)位14:电机正向旋转=r2197.3位15:变频器过载警告=r2135.15(取反)控制字1 位00:ON/OFF1 =r0898.0 =P840位01:OFF2 =r0898.1 =P844/P845位02:OFF3 =r0898.2 =P848/P849位03:使能运行=r0898.3=P852位04:使能斜坡函数发生器=r0898.4 =P1140位05:继续斜坡函数发生器=r0898.5 =P1141位06:使能转速设定值 =r0898.6 =P1142位07:故障复位=r0898.7=P2103/P2104/P2105位08:JOG 0 =r0898.8 = P1055位09:JOG 1 =r0898.9 = P1056位10:通过PLC控制 =r0898.10 =P854位11:设定值取反=r1198.11 =P1113位12:位13:MOP 上升 =r1198.13 =P1035位14:MOP 下降 =r1198.14=P1036位15:P840 ON/OFF1命令P844/P845 OFF2P848/P849 OFF3P852 使能P854 PLC控制P1140 使能斜坡函数发生器P1141 继续斜坡函数发生器P1142 使能转速设定值P1113 设定值取反(反向)P2103/P2104/P2105 故障复位r055 附加控制字r056 闭环控制状态字r060未滤波的转速设定值rpmr061 未滤波的转速实际值rpmr068 直流母线的直流电流/电机实际电流绝对值r069 相电流实际值(电机模块)r070 直流母线电压6.通讯P918 Profibus通讯地址P922 Profibus报文格式选择 1:标准报文1,PZD2220:标准报文20,PZD26350:西门子报文350,PZD44352:西门子报文352,PZD66353:西门子报文353,PZD22,PKW44354:西门子报文354,PZD66,PKW44999:自由报文7.其他设定源P1000 主给定设定来源 0:无主设定值1:电动电位计2:模拟设定值3:转速固定设定值6:现场总线P1070 主给定r755:模拟设定值r1024:固定设定值r1050:电动电位计P1075 附加给定 r755:模拟设定值r1024:固定设定值 r1050:电动电位计:P1055 点动命令位0 (JOG1的信号源)P1056 点动命令位1 (JOG2的信号源)P1058 JOG1 转速设定值P1059 JOG2 转速设定值P1035 电动电位计MOP正向升速命令源P1036 电动电位计MOP反向降速命令源P1037 电动电位计最大转速P1038 电动电位计最小转速P1039 电动电位计MOP取反P1040 电动电位计MOP初始值rpmP1080 最小速度rpmP1082 最大速度rpmP1083 正向速度极限rpmP1086 反向速度极限rpmP1085 正向速度极限信号源P1088 反向速度极限信号源P1110 禁止负方向P1111 禁止正方向P1113 设定值取反信号源P1120 RFG加速时间P1121 RFG减速时间P1135 OFF3下降时间P1503 转矩设定值信号源P1520 转矩上限P1521 转矩下限P1522 转矩上限信号源P1523 转矩下限信号源P855 强制打开抱闸P856 强制闭合抱闸P810 命令数据组选择CDS位0P811 命令数据组选择CDS位1P820 驱动数据组选择CDS位0P821 驱动数据组选择CDS位1P700 命令源选择 0:没有宏 2:端子6:现场总线 170:JOG1181:2线类型2181:2线类型3181:3线类型1181:3线类型2P2106/P2107/P2108 外部故障1/外部故障2/外部故障3P2112/P2116/P2117 外部报警1/外部报警2/外部报警3P640 电流极限P1300 开环/闭环方式P1755 无编码器运行时速度8.数字及模拟量输入输出r720 CU上数字输入输出数量r721 CU上数字输入实际值r722 CU上数字输入状态P730 数字输出DO 0的信号源选择P731 数字输出DO 1的信号源选择P732 数字输出DO 2的信号源选择r747 数字输出状态P748 数字输出取反r751 模拟输入状态P756 模拟输入类型选择 0:单极电压输入(0 (10V)1:监控单极电压输入(+2V (10V)2:单级电流输入(0mA……+20mA)3:监控单级电流输入(+4mA……+20mA)4:双击电压输入(10V (10V)8:未连接传感器P771 模拟输出信号源P772 模拟输出当前输出值%P776 模拟输出类型0:电流输出(0mA……+20mA)1:电压输处(0 (10V)2:电流输出(+4mA……+20mA)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

38 47 85
Rated Ripple (mArms) at 105°C 120Hz
Frequency coefficient of rated ripple current
V
Cap.(µF) Frequency
6.3 ~ 100 160 ~ 450
100 ~ 680 1000 ~ 4700 6.8 ~ 100
After storing the capacitors under no load at 105°C for 1000 hours, and after performing voltage treatment based on JIS C 5101-4 clause 4.1 at 20°C, they will meet the specified value for endurance characteristics listed above. Printed with white color letter on black sleeve.
Capacitance change tan δ Leakage current
Within ± 20% of initial value 200% or less of initial specified value Initial specified value or less
Shelf Life Marking
63 0.10
100 0.08
160 ~ 350 400 ~ 450 0.20 0.25 400 6 10 450 15
Measurement frequency : 120Hz
Stability at Low Temperature
Rated voltage ( V) Impedance ratio Z– 25˚C / Z+20˚C ZT / Z20 (MAX.) Z– 40˚C / Z+20˚C
70 85 120 160
V Cap.(µF) Code
350 2V 16 × 12.5 18 × 12.5 25 × 12.5 75 90 140
400 2G 16 × 12.5 20 × 12.5 25 × 12.5 65 150 200
6.8 10 22 33
6R8 100 220 330
450 2W 12.5 × 12.5 16 × 12.5 25 × 12.5
– 55 ~ +105°C (6.3 ~ 100V), – 40 ~ +105°C (160 ~ 400V), – 25 ~ +105°C (450V) 6.3 ~ 450V 6.8 ~ 4700µF ± 20% at 120Hz, 20°C
Rated voltage (V) 6.3 ~ 100 After 1 minute's application of rated voltage, leakage current is not more than 0.03CV or4 (µA), whichever is greater. After 2 minutes' application of rated voltage, leakage current is not more than 0.01CV or 3 (µA), whichever is greater.
160 2C
200 2D 12.5 × 12.5 16 × 12.5 18 × 12.5 25 × 12.5 110 170 230 310
250 2E 16 × 12.5 18 × 12.5 22 × 12.5 130 170 190
10 22 33 47 68 100 220 330 470
100 220 330 470 680 101 221 331 471
12.5 × 12.5 18 × 12.5 25 × 12.5
500 770 1170
50 1H 12.5 × 12.5 20 × 12.5 25 × 12.5
450 540 700
Case size
Rated ripple
φ D × L (mm)
V Cap.(µF) Code
63 1J
100 2A
50Hz 0.80 0.85 0.80
120Hz 1.00 1.00 1.00
300Hz 1.23 1.10 1.25
1 kHz 1.34 1.13 1.40
10 kHz ~ 1.50 1.15 1.60
CAT.8100V
High Temperature
RU
Specifபைடு நூலகம்cations
Item Category Temperature Range Rated Voltage Range Rated Capacitance Range Capacitance Tolerance Performance Characteristics
2 3
63~ 100 160 ~ 200 250 ~ 350 2 3 4 3 4 8
Endurance
After 2000 hours' application of rated voltage at 105°C, capacitors meet the characteristic requirements listed at right.
φD
P
12.5 5.0 0.6
16 7.5 0.8
18 7.5 0.8
20 10.0 1.0
22 10.0 1.0
25 12.5 1.0
φd
HD RD
• Please refer to page 21 about the end seal configulation.
Please refer to page 21, 22, 23 about the formed or taped product spec. Please refer to page 3 for the minimum order quantity.
330 470 680 1000 2200 3300 4700
331 471 681 102 222 332 472
12.5 × 12.5 18 × 12.5 25 × 12.5
580 730 1200
18 × 12.5 22 × 12.5
820 1030
12.5 × 12.5 25 × 12.5
520 1000
For capacitance of more than 1000µF, add 0.02 for every increase of 1000µF.
160 ~ 450
After 1 minute's application of rated voltage,
Leakage Current
I = 0.04CV+100 (µA) or less
Dimension table in next page.
CAT.8100V
元器件交易网
ALUMINUM ELECTROLYTIC CAPACITORS
RY
Cap.(µF)
series
Dimensions
V Code
6.3 0J
10 1A
16 1C
25 1E
35 1V 12.5 × 12.5 18 × 12.5 22 × 12.5 420 610 810
元器件交易网
ALUMINUM ELECTROLYTIC CAPACITORS
RY
12.5mmL Wide Temperature Range
series
12.5mmL height. Adapted to the RoHS directive (2002/95/EC).
RY
Pressure relief vent L+
MAX
Rated voltage (10V)
15MIN 4MIN (mm)
Series name Type Configuration φD 12.5 ~ 18 20 ~ 25
Pb-free leadwire Pb-free PET sleeve
(φ D < 20) 1.5 (φ D 20) 2.0
12.5 × 12.5 18 × 12.5 22 × 12.5
400 550 610
12.5 × 12.5 22 × 12.5
230 400
12.5 × 12.5 16 × 12.5 20 × 12.5 25 × 12.5
130 210 280 360
315 2F 12.5 × 12.5 16 × 12.5 20 × 12.5 25 × 12.5
Measurement frequency : 120Hz, Temperature : 20°C
tan δ
Rated voltage (V)
tan δ (MAX.)
6.3 0.28
10 0.24 6.3 5 10
16 0.20 10 4 8
25 0.16 16 3 6
35 0.14 25 2 4
50 0.12 35~ 50
Radial Lead Type
Sleeve (P.E.T.)
Type numbering system (Example : 10V 2200µF)
φd
1 2 3 4 5 6 7 8 9 10 11
URY 1 A 2 2 2 MHD
φD+0.5 MAX P ± 0.5
Configuration Capacitance tolerance (±20%) Rated Capacitance (2200µF)
相关文档
最新文档