SyscalPro2009-AU

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

IRIS INSTRUMENTS
SYSCAL Pro
resistivity & IP equipment
for SOUNDING, IMAGING
and MONITORING
R E S I S T I V I T Y S O U N D I N G A N D I M A G I N G S Y S T E M
PC SOFTWARE:
- ELECTRE Pro: sequence management - PROSYS II: data transfer, process, display - COMSYSPro: control of SYSCAL by PC - SYSMAR: continuous acquisition - PROCESSING: x2ipi (w/seq manag.) - INTERPRETE: ERTLab (w/seq manag.)
Res2/3Dinv, IX1D, Winsev
2D interpreted resistivity section
400 readings, 5’ measuring time
SYSCAL Pro Switch 48
ELECTRODE ARRAYS
depth / line length
signal strength
lateral resolution
field set up
Wenner Sclumb
20%
regular
regular
regular
Dipole Dipole
20%
weak
best
regular
Pole Dipole
35%
medium
good
medium
Pole Pole
90%
best
weak
weak
SYSCAL Pro Switch
48
72
96
120
5m spacing
total line length
2 seg x 24 elect
240m
4 seg x 18 elect
360m
6 seg x 16 elect
480m
12 seg x 10 elect
600m
10m spacing
total line length
4 seg x 12 elect
480m
8 seg x 9 elect
720m
12 seg x 8 elect
960m
24 seg x 5 elect
1 200m
SYSCAL Pro Switch for resistivity imaging
SYSCAL Pro Switch 48 multi-electrode
equipment
Automatic (or manual) numbering of electrodes
Automatic (or manual) generation
of the sequence of
readings
Visualization of the investigation points 2D IMAGING (1 LINE)
3D IMAGING
(SEVERAL PARALLEL LINES)
apparent resistivity profiles, PROSYS II
20
40
SYSCAL Pro Switch for resistivity monitoring
Field PC
SYSCAL Pro for resistivity sounding
SYSCAL Pro options and accessories
BOREHOLE CABLES for hole-to-hole surveys
ERTLab
3D interpretation software
SYSCAL Pro
P11 P9 P7 P5 P3 P1 C1 C2 P2 P4 P6 P8 P10
2m
SYSCAL Pro
GPS pulling cable
electric cable
SYSCAL
Pro
P11 P9 P7 P5 P3 P1 C1 C2 P2 P4 P6 P8 P10
spacing
10m 20m 30m 0m interpreted resistivity section
IRIS Instruments, 1 avenue Buffon, BP 6007, 45060 ORLEANS Cedex 2, FRANCE
Tel:+33238638100Fax:+33238638182E-mail:****************************:
SYSCAL Pro for continuous land survey
SYSCAL Pro for river and sea survey
DYNAMIC ACQUISITION for LAND SURVEYS
• The SYSCAL Pro can be used
with a specific cable pulled on the ground by a light vehicle, for a
continuous acquisition of resistivity readings. • The cable features 13 cylindrical
stainless steel electrodes (8cm diameter, 25cm length, 4.2kg) at 2m spacing :
- 2 for transmitting the current, - 11 for simultaneously measuring ten potential channels.
• A PC continuously records the 10
resistivity values and the GPS data, displays profiles in real time
• Recommended electrode array:
reciprocal Wenner Schlumberger
• Penetration depth: about 5m • Best conditions: wet grounds • Acquisition speed: typ. 3km/h
electrodes
DYNAMIC ACQUISITION for RIVER & SEA SURVEYS
• The SYSCAL Pro can be used
with a specific cable pulled on the surface of water (lake, river or sea) by a light boat, for a continuous acquisition of
resistivity readings.
• The cable features 13 cylindrical
graphite electrodes (4cm diameter, 10cm length) at 5m spacing :
- 2 for transmitting the current, - 11 for simultaneously measuring
ten potential channels.
• A PC continuously records the 10
resistivity / IP values and the GPS data, displays profiles in real time
• GPS track vizualisation on
Google Earth
• Recommended electrode array:
reciprocal Wenner Schlumberger
• Penetration depth: about 15m
with a 100m total length cable
• Acquisition speed: typ. 3km/h
electrode float
stainless steel current electrode
SYSCAL Pro Deep Marine is a SYSCAL
Pro dedicated to measurement in sea water:
• with outputs of 50V, 50A , 2500W • for higher penetration
• for higher speed (up to 10km/h)
• with reciprocal Wenner-Schlumb & dip-dip
It uses the same graphite electrode cable as the SYSCAL Pro for the measurement of the potential, but stainless steel electrodes for the current (5cm diameter, 30cm length)
It can be used with a cable of 25m spacing between electrodes (total cable length 350m), for a depth of penetration of about 60m
cable with graphite electrodes
Current electrode of SYSCAL Pro Deep Marine
interpreted resistivity section
PC
GPS
SYSCAL Pro
CABLE
GPS
track。