2.03.200A02 产品操作使用说明书
M03.0022_Chinese_2022-07说明书

操作说明控制器B500/B510C540/C550P570/P580M03.0022 CHINESISCH原版使用说明书 ◼ Made ◼ in ◼ GermanyCopyright© Copyright byNabertherm GmbH Bahnhofstrasse 2028865 LilienthalFederal Republic of Germany Reg: M03.0022 CHINESISCH Rev: 2022-07内容可能会修改,保留技术更改权利1引言 (7)2质保和责任 (8)2.1一般说明 (8)2.2环境条件 (9)2.3废料处理 (9)2.4产品说明 (9)2.5规定用途 (10)2.6符号说明 (10)3安全说明 (13)4运行 (14)4.1接通控制器/窑炉 (14)4.2关闭控制器/窑炉 (14)5控制器的构造 (15)5.1控制器的各个模块的布局 (15)5.2操作页面区域 (16)5.2.1“菜单栏”区域 (16)5.2.2“小区段播放器”区域 (17)5.2.3“大区段播放器”区域 (18)5.2.4“状态栏”区域 (19)6控制器性能特性 (20)7简要使用说明 B500/B510/C540/C550/P570/P580 (22)7.1基本功能 (22)7.2输入新程序 (程序表) (24)8概览图 (29)8.1“窑炉”概览(无程序处于活动状态) (29)8.2“窑炉”概览(程序处于活动状态) (29)9待机模式 (31)10显示、输入或更改程序 (31)10.1“程序”概览 (32)10.2显示并启动程序 (33)10.3分配并管理程序类别 (34)10.4输入程序 (36)10.5利用NTEdit在电脑上准备程序 (44)10.6管理程序(删除/复制) (44)10.7什么是Holdback? (45)10.8修改正在运行的程序 (46)10.9完成区段跳跃 (47)11设定参数 (48)11.1“设置”概览 (48)11.2校准量程 (48)11.3调节参数 (52)11.4调节性能 (54)11.4.1磨平 (54)11.4.2加热延迟 (55)11.4.3手动区段控制 (56)11.4.4在程序启动时将实际值作为额定值接受 (57)11.4.5受控冷却(选项) (58)11.4.6起动连接/功率限制 (60)11.4.7自优化 (61)11.4.8程序运行中的炉料控制 (63)11.4.9用于各个区间的额定值补偿 (65)11.4.10Holdback (66)11.5用户管理 (67)11.6控制器锁闭和操作禁用 (71)11.7连续锁闭(操作禁用) (71)11.7.1运行中的程序控制器锁闭 (71)11.8配置额外功能 (72)11.9收起或重命名附加功能 (73)11.9.1在一个加热程序运行期间人工操作额外功能 (73)11.9.2在一个加热程序之后人工操作额外功能 (74)11.10警报功能 (75)11.10.1警报 (1 和 6) (75)11.10.2可听报警(可选) (78)11.10.3监测梯度 (78)11.10.4警报配置举例 (80)11.11设定电网中断时的反应 (81)11.12系统设置 (82)11.12.1设定日期和钟点时间 (82)11.12.2设置日期和钟点时间格式 (82)11.12.3设定语种 (83)11.12.4调节显示屏亮度 (84)11.12.5调整温度单位 (°C/°F) (84)11.12.6设定数据接口 (85)11.12.7设置Wi-Fi端口 (88)11.13导入和导出过程数据、程序和参数 (90)11.14登录模块 (92)11.15对空气循环器的控制 (93)12信息菜单 (93)13过程记录 (95)13.1使用NTLog将数据保存到U盘 (95)13.2保存过程数据并使用VCD软件管理程序(可选) (99)14连接到MyNabertherm App (100)14.1故障排除 (104)15与控制器的通信 (104)15.1通过 Modbus-TCP 和上一级系统进行沟通 (104)15.2网络服务器 (105)15.3通信模块的补装 (107)15.3.1供货范围 (107)15.3.2安装一个通信模块 (107)16可设置关闭温度的温度选择限制器(附加配置) (109)17无电势触点用于开启外部设备以及接收监控信号(可选) (109)18故障消息或警告 (110)18.1控制器的故障消息 (110)18.2控制器警告 (112)18.3开关设备的故障 (114)18.4控制器的检查列表 (115)19技术数据 (117)19.1铭牌 (119)20清洁 (119)21维护和备件 (119)21.1更换一个控制器 (120)21.2调节器模块的拆卸 (120)21.3调节器模块的安装 (121)22电气连接 (121)22.1调节器模块 (121)22.2对电缆的要求 (122)22.3一般性连接 (122)22.4至 3.6 kW 的窑炉–用于 B130, B150, B180, C280, P330 的备件,截止 2008 年 12 月止 (123)22.5至 3.6 kW 的窑炉–用于 B130, B150, B180, C280, P330 的备件,从 2009 年 1 月起 (124)22.6窑炉,单区式> 3.6 k,带半导体继电器或接触器 (125)22.7窑炉> 3.6 kW,带 2 个加热回路 (126)23纳博热售后服务 (127)24您的备忘录......................................................................................................... Fehler! Textmarke nicht definiert.1 引言尊敬的客户:非常感谢您对纳博热有限公司产品的信任和支持。
CAMOZZI 2系列手动操作微型阀门说明书

CARACTERÍSTICAS GENERALES
Grupo válvula
Vías/Pos. 3/2
Construcción
con obturador (centros cerrados)
Materiales
cuerpo en AL - obturador en latón - juntas en NBR
Sujeción
de panel
Conexiones
M5 - cartucho ø 4
Temperatura ambiente 0°C ÷ 60°C
Temperatura fluido 0°C ÷ 50°C
Presión de trabajo
ver modelos
Productos para aplicaciones industriales. Condiciones Generales de Venta disponibles en .
C (Suministro/puerto) Ø4/2 M5 Ø4/2 M5
Símbolos VN02 VN02 VN31 VN31
Productos para aplicaciones industriales. Condiciones Generales de Venta disponibles en .
MINIVÁLVULAS DE ACCIONAMIENTO MANUAL SERIE 2
Mod. 234-975 235-975 244-975 245-975
Presión de trabajo (bar) 2÷8 2÷8 2÷8 2÷8
Caudal (Nl/min) 60 60 60 60
Fuerza de accionamiento 7 7 7 7
ZO系列氧化锆氧量分析仪使用说明书

目录1 概述 (1)2 仪器测量原理 (2)3 仪器主要技术参数 (3)4 仪器简介 (4)4.1 仪器组成 (4)4.2 各部分简介 (4)4.2.1 探头简介 (4)4.2.2 变送器简介 (5)4.2.2.1 基本结构 (5)4.2.2.2 基本操作 (6)4.2.2.3 基本设置 (7)5 仪器检验 (7)6 仪器安装 (9)6.1 安装前的准备 (9)6.1.1 探头安装位置的选择 (9)6.1.2 炉体法兰的焊接 (10)6.1.3 现场布线 (11)6.2 安装 (12)6.2.1 变送器的安装 (12)6.2.2 探头的安装 (12)6.3 现场连线 (13)7 仪器校准 (13)7.1 校准前的准备 (13)7.2 校准方法 (14)8 仪器日常维护与常见故障排除 (15)8.1 仪器日常维护 (15)8.2 常见故障的分析与排除 (16)1 概述氧化锆氧分析仪主要用于测定锅炉烟气中的氧分压即氧气的体积百分数含量(简称氧含量或氧量),对于保障锅炉运行安全、提高燃料燃烧效率及减少环境污染将起到重要作用。
其应用场所主要有:●火电厂锅炉;●炼油厂加热炉和输油管道加热炉;●冶炼厂加热炉和均热炉;●化工、轻纺、食品加工、制药、水泥和采暖等企业的工业锅炉。
燃料燃烧效率与空气过剩系数密切相关。
在燃烧过程中,当空气过剩系数太小即氧量不足时,由于燃料未充分燃烧而导致热效率降低,且排出的未完全燃烧气体也将对导致环境污染;而当空气过剩系数太大即氧量过多时,虽然能使燃料充分燃烧,但过剩空气带走的热量多,也导致热效率降低,同时过量氧气使烟气中硫化物和氮氧化物含量增大,同样导致环境污染。
因此,通过安装氧化锆氧分析仪,在线实时监测烟气中的氧含量,调节空气和燃料的最佳配比,实现优化燃烧,在节能减排与安全环保等方面具有重要意义。
中国原子能科学研究院始建于1950年,是中国核科学技术的发祥地,是以核科学为主、多学科并存的综合性大型科研基地,是我国“两弹一艇”事业的摇篮。
全数字二保焊机控制器使用说明书

焊接电源
YD-350GB2
控制器
YD-00DER1
送丝装置 可选六种
焊枪 可选六种
连接电缆 可选八种
气体控制器 可选三种
本产品与送丝机连接、相对焊机和送丝机,主要实施焊接条件的设定、监测、焊接条件的存储・再生、 焊丝摆动、气体检查等。
■特 长
●控制器能进行全部的操作。 ●带有可监测焊接条件、电机送丝负荷的LED监测器。 ●液晶画面可进 ...................................................................... 4 2.规格 .................................................................................. 5
・焊接电流1A、焊接电压0.2V 的最小设定刻度。 ●可以一元化/个别调整。 ●能正确把握焊丝使用量及电弧时间。
■关于产品安全
请正确理解与本产品的安装・使用・服务相关・焊机(焊接用直流电源)及其他相关设备的使用说明书 中记载的安全事项。
【本产品废弃时的注意事项】
本产品废弃时、应和接受工业废弃物处理业者签订废弃处理委托合同、委托其实施废弃处理。
5.2.1 「控制 切换」(控制切换) ............ エラー! ブックマークが定義されていません。 5.2.2 「焊丝直径」(焊丝直径) ............. エラー! ブックマークが定義されていません。 5.2.3 「焊丝 材质」(焊丝材质) ............ エラー! ブックマークが定義されていません。 5.2.4 「保护气体」(保护气体的种类) ....... エラー! ブックマークが定義されていません。 5.2.5 「一元・个别」(一元化・个别 控制切换) ....................................... 19 5.2.6 「电流・电压」(焊接电流・电压设定) ......................................... 19 5.2.7 「半自动・自动」(自动 焊接时的焊丝伸出长度) ................................. 19 5.2.8 「电弧点焊 TIME」(电弧点焊時间) ........................................ 19 5.2.9 产品出厂时的焊接条件数据表(标准规格品) .................................... 20 6. 其他条件的变更 ...................................................................... 21 6.1 变更方法 ...................................................................... 21 6.2 <B>表示・组 ................................................................ 21 6.2.1 「电机 旋转数」(送丝电机旋转数) ............................................ 21 6.2.2 「电机 电流」(送丝电机電流) ................................................ 22 6.2.3 「短路 次数」(电弧短路次数) ................................................ 22 6.2.4 「焊接 次数」(焊接次数) .................................................... 22 6.2.5 「焊接工件时间」(焊接工件時间) ............................................. 22 6.2.6 「电流・焊丝量」(焊接电流/送丝量表示切换) ................................. 22 6.2.7 「一元表示」(一元化设定时的电压表示方法的切换) ............................. 22 6.2.8 「显示语言」(显示语言) ..................................................... 22 6.2.9 「显示保持时间」(显示保持时间) ............................................. 22
气动平行闸阀使用说明书

3
28
360
310
25
12
M22
278
3
30
425
370
30
12
M27
332
3
32
485
430
30
16
M27
390
4
36
550
490
34
16
M30
448
4
40
610
550
34
16
M30
505
4
44
660
600
34
20
M30
555
4
46
730
660
41
20
M36
610
4
48
840
770
41
20
M36
720
0.5
4.35 3.39 2.40 1.58
0.3
4.66 3.17 2.17 1.42 0.73 0.56 0.39
0.4
6.00 4.14 2.99 1.97 1.04 0.81 0.59
0.5
6.00 5.26 3.81 2.51 1.34 1.06 0.79
0.3
3.26 2.19 1.19 0.94 0.69 0.48
公称 公称
通径 DN
(mm)
压力 PN MPa
阀门 长度
L
高度 H
15
130
530
20
150
540
2540
240
600
50
250
655
65
270
820
80
流式细胞仪操作规程 (1)

流式细胞仪操作规程目录1:淋巴细胞亚群测定2:HLA-B27测定3:CD55/CD59测定4:血小板抗体测定5:红细胞抗体测定6:粒细胞抗体测定7:白血病免疫分型测定8:淋巴细胞T细胞亚群细胞内因子IFN-γ/IL-4测定9:XL操作步骤淋巴细胞亚群测定(流式细胞仪)医院检验科操作规程文件号:200 年月日起实施第1版(共3页)本规程每2年复审一次复审日期:年月日复审人:规程编写者:审批者:批准日期:年月日文件分发部门和/或个人院档案室保管者:检验科主任:检验科实验室:淋巴细胞亚群测定(C D系列)方法流式细胞仪(BeckmanCoulter,贝克曼库尔特)原理:双/三色直接免疫荧光法。
荧光素标记的各种单克隆抗体加入到全血中,与白细胞膜上相应的抗原结合,经过溶血、洗涤(和固定)等步骤后,在流式细胞仪上进行分析,从而得到淋巴细胞亚群的百分数。
淋巴细胞表面抗原分布如下:T淋巴细胞:CD3+;B淋巴细胞:CD5+,CDl9+;辅助性T淋巴细胞:CD3+CD4+;抑制性T淋巴细胞:CD3+CD8+;NK细胞:CD3-CDl6+56+等。
根据淋巴细胞膜上CD分子表达的不同,流式细胞仪可以分辨出淋巴细胞及其各种不同的亚群,利用计算机软件计算出淋巴细胞亚群的百分数。
标本采集与处理受检者的准备检查对象生活饮食处于日常状态,空腹采血。
采集部位静脉采血抗凝剂 EDTA或肝素抗凝血要求 1.样本量至少1ml。
2.样本应在采集后6小时内处理,冷冻的标本不能用。
3.样本白细胞计数应在4.0-10.0×109/L之间。
若>10.0×109/L,样本需要稀释,用PBS稀释;若<4.0×109/L,应分离单个核细胞。
4.溶血样本不能用。
试剂品牌剂型规格贮存贝克曼库尔特成分 1:单克隆抗体液体 1ML 2—8℃2:全血溶血试剂液体A:甲酸液体 70ML 室温B:碳酸钠等液体 32ML 室温C:多聚甲醛液体 14ML 室温3:鞘液液体 20L 室温4:清洗液液体 5L 室温5:荧光微球液体 10ML 2-8℃质控品 BEKAMANCOULTER产品,未开瓶的试剂于2-8℃保存,可在有效期内保持稳定,稀释的试剂于2-8℃可稳定2周;每天校准一次:遇特殊情况随时进行校准。
唐山大方汇中仪表 LZD系列 智能电磁流量计 说明书

LZD系列智能电磁流量计安装使用说明书唐山大方汇中仪表有限公司通过ISO9001:2008质量管理体系认证冀制02000110Ex1.3.7压力:1.6Mpa;2.5Mpa; 6.4Mpa; 16Mpa; 25Mpa; 42Mpa 1.3.8使用环境:环境温度:-20℃~+50℃ 相对湿度:5%~90%1.3.9空管自动报警1.3.10机械振动频率:≤55Hz 振幅:≤0.15mm 1.3.11平均无故障工作时间:MTBF=30000h 1.3.12防护等级:IP67或IP651.3.13防爆标志:Exd(ia)iaqⅡCT51.3.14衬里材料:聚氨酯橡胶、氯丁橡胶;聚四氟乙烯;F46衬里。
1.3.15电极材料:不锈钢、316L、HB;特殊材料(如:钛、钽、铂等稀有金属材料。
)1.3.16供电电源:85~265VAC或18~36VDC 1.3.17额定功率:小于10W二、工作原理及结构2.1工作原理电磁流量计的工作原理基于法拉第电磁感应定律。
当一个导体在磁场内运动时,在与磁场方向、运动方向相互垂直方向的导体两端,会有感应电动势产生。
电动势的大小与导体运动速度和磁感应强度大小成正比。
在图下中,当导电流体以平均流速V(m/s)通过装有一对测量电极的一根内径为D (m)的绝缘管子流动时,并且该管子处于一个均匀的磁感应强度为B(T)的磁场中,将在一对电极上就会感应出垂直于磁场方向和流动方向的电动势(E)。
有电磁感应定律可写做(1)式:q v =πD 24V(m 3/ )s ...................(2)由公式(1)和(2)可得到:q v =πD 4E B(m 3/ )s (3)通常,体积流量可以写作唐山大方汇中仪表有限公司0315-2833937唐山新华西道21号http://www.tsdafang.com图三、执行标准3.1执行标准Q/DF004-2009 LZD系列电磁流量计U因此电动势可表示为:E=πD4B q v(v) (4)当B是个常数时,公式(3)中πD 41B =k,公式(3)改写为:q v =kE (m 3/ )s因此,流量 与电动势E成为正比。
一次性手套使用说明书

使用说明书
感谢您购买我司一次性手套产品,在使用本产品前请仔细阅读以下使用说明:
【产品名称】一次性乳胶手套、一次性丁腈手套
【规格型号】XL、L、M、S、XS
单位:毫米尺寸代码标称尺寸宽度最小长度最小厚度最大厚度6和6以下特小号(XS)≤80 220
对所有尺寸:光面:0.08 麻面:0.11 对所有尺寸:光面:2.00 麻面:2.03
6.5 小号(S) 80〒5 220
7 中号(M) 85〒5 230
7.5 中号(M) 95〒5 230
8 大号(L) 100〒5 230
8.5 大号(L) 110〒5 230
9和9以上特大号(XL) ≥110 230
【品种】有粉和无粉,光面和麻面。
【产品标准】产品符合GB10213-2006标准
【产品性能结构及组成】该产品由天然橡胶胶乳、丁腈为原料,经过胶乳配制、浸凝固剂、浸胶乳、浸粉水、硫化烘干、脱模、干燥等工序制成。
【适用范围】该产品用于食品加工;汽车和机械维修;精密安装;基础化学防护;清洁操作;实验室等场所。
【注意事项】
1、严禁接触油、酸、碱、铜、锰等对橡胶有害的金属和化学药物;
2、严禁阳光或紫外线等强烈光线直接照射;
4、对天然橡胶制品使用有过敏史者慎用;
【使用说明】
1、本产品不分左右手,请选择适合本人手型规格的手套;
2、穿戴手套时,不得戴戒指或其他饰物,注意修剪指甲;
3、本产品限一次性使用;使用后的产品请按医疗垃圾处理,防止病菌对环境污染。
【储存条件、方法】应储存在通风良好,阴凉干燥的仓库内(室内温度30度以下,相对湿度80%以下为宜)离地面200mm的货架上;
【有效期】本产品自制造之日起,有效期限24个月。
天津康德科 G2 220V电磁阀 说明书

目录一、安全注意事项 (4)1.1 应用范围 (4)1.2 使用前 (4)1.2.1 拆箱检查 (4)1.2.2 环境确认 (4)1.2.3 安装确认 (4)二、ED200系列产品简介 (4)2.1 产品简介 (4)2.2 产品命名 (5)2.3 产品铭牌 (5)2.4 技术规范 (5)2.4.1 电气规格 (5)2.4.2 环境条件 (5)2.4.3 功能规格 (6)2.5 各部分介绍 (7)2.6 按键功能 (7)2.7 接口定义及下载连接 (8)2.7.1 接口引脚定义 (8)2.7.2 下载连接 (8)三.产品体系结构 (9)3.1 外形尺寸及安装方法 (9)3.2 安装 (9)3.3 PLC连接使用方法 (9)3.3.1 连接单元 (10)3.3. 2 通讯参数设置 (10)3. 3.3 电缆连接 (11)四. EuraDesign上位机软件介绍 (11)4.1 画面编辑和工程下载方法 (12)4.1.1 建立新工程 (12)4.1.2 制作画面 (15)4.1.3 保存工程 (16)4.1.4 下载工程 (17)4.1.5 画面数据溢出 (18)4.2 控件使用说明 (18)4.2.1 静态文本及静态矢量文本 (18)4.2.2 动态文本及动态矢量文本 (19)4.2.3 指示灯 (19)4.2.4 功能键 (20)4.2.5 寄存器 (25)4.2.6 柱状图 (28)4.2.7 趋势图 (28)4.2.8 图片 (29)4.2.9 告警控件 (30)4.2.10 报警列表 (30)五.常见问题 (31)5.1 程序无法下载 (31)5.2 文本屏和PLC 等设备通讯问题 (31)5.3 程序保密性 (32)敬告用户 (33)一、安全注意事项本章对与本产品相关的安全注意事项进行说明。
如果不遵守这些注意事项,可能会损坏本产品。
因未遵守本使用说明书的内容而造成设备损坏,本公司将不负任何责任。
说明书 az UF 1002 UF 1302 UF 1602 UF 2002 带便捷功能套件CP的农

CO2-200 CO2 检测器用户手册说明书

Users Manual • Mode d’emploi• Bedienungshandbuch• Manual d’Uso• Manual de usoCO2-200CO2 MeterCO2-200 CO2 MeterUsers ManualJuly 2009, Rev.1©2009 Amprobe Test Tools.All rights reserved. Printed in ChinaLimited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in materialand workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY.ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FORA PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.RepairAll test tools returned for warranty or non-warranty repair orfor calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe® Test Tools.In-Warranty Repairs and Replacement – All CountriesPlease read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe® Test Tools distributorfor an exchange for the same or like product. Please check the “Where to Buy” section on for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe® Test Tools Service Center (see address below).Non-Warranty Repairs and Replacement – US and CanadaNon-warranty repairs in the United States and Canada should be sent to a Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire at your point of purchase for current repair and replacement rates.In USA In CanadaAmprobe Test Tools Amprobe Test ToolsEverett, WA 98203 Mississauga, ON L4Z 1X9Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600Non-Warranty Repairs and Replacement – EuropeEuropean non-warranty units can be replaced by your Amprobe® Test Tools distributor for a nominalv charge. Please check the “Where to Buy” section on for a list of distributors near you.European Correspondence Address*Amprobe® Test Tools EuropeIn den Engematten 1479286 Glottertal, GermanyTel.: +49 (0) 7684 8009 - 0*(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)CO2-200 CO2 Meter1 3 5 7 9 11Humidity SensorAlarm OutputDC JackCAL/ESC ButtonDP/WB ButtonBeeper24681012LCD DisplayUSB PortSET ButtonRESET ButtonMNX/AV ButtonLED LightLCD DisplayPrimary Screen Displays CO2 Concentration Relative Humidity In %Air, Dew Point, Wet Bulb T emperature Display CO2 Measurement Mode Minimum/Maximum readingsTime Weighted Average (8 Hours)Short-T erm Exposure Limit (15 Minutes Weighted Average)Dew Point T emperatureAir temperatureWet Bulb T emperature12345791068CONTENTS SYMBOLS (2)UNPACKING AND INSPECTION (2)INTRODUCTION (3)Features (3)OPERATION (4)Alarm output (5)Setup (6)Calibration Mode (7)• CO2 calibration (8)• Manual calibration (8)• Humidity calibration (7)USB Interface capabilities (8)SPECIFICATIONS (9)MAINTENANCE (10)TROUBLE SHOOTING (11)APPENDIX (12)1SYMBOLS�Caution! Refer to the explanation in this Manual�Conforms to relevant Australian standards�Complies with European Directives=Do not dispose of this clamp meter asunsorted municipal waste. Contact a qualifiedrecycler for disposal.�Warning and Precautions• Avoid condensation on CO2 sensor• Do not hold the meter close to faces in caseexhalation affects CO2 levels.• Do not calibrate the meter in the air withunknown CO2 concentration. Otherwise, it willbe calibrated as 400ppm by default and leads toinaccurate measurements.UNPACKING AND INSPECTIONYour shipping carton should include:1 CO2-200 CO2 Meter1 Adaptor1 User manual1 Plain white boxIf any of the items are damaged or missing, returnthe complete package to the place of purchase for an exchange.2INTRODUCTIONThank you for purchasing this CO2 meter. It measures CO2 level, air temp., dew point, wet bulb temp. and humidity and is an ideal instrument for indoor air quality (IAQ) diagnosis.Poor indoor air quality is considered unhealthy because it causes tiredness, loss of ability to concentrate, and even illness (ex. Sick Building Syndrome). IAQ monitoring and survey, especially on CO2 level and air ventilation become widely applied in public areas such as offices, classrooms, factories, hospitals and hotels. It is also suggested in regulations of industrial hygiene in some countries. (Appendix)With NDIR (non-dispersive infrared) sensor used, thisCO2 meter is stable in long term monitoring. And the built-in relay for alarm output is especially useful in ventilation control and HVAC system performance verification.Features• Triple displays of CO2 level, temp. and humidity.• Stable NDIR sensor for CO2 detection.• Statistics of weighted averages (TWA & STEL)• Visible and audile CO2 warning alarm• Alarm output for ventilation control• Battery and adaptor power supply• ABC(Automatic Baseline Calibration) and manualCO2 calibration• USB PC connection3OPERATION1. Plug in the adaptor and the meter turns onautomatically with a short beep. It performs30 seconds countdown (Fig.1) for meter warmup, then enters normal mode with current CO2,temperature, and humidity readings displayed.2. The meter starts taking measurements whenpower on and updates readings every second. Inthe condition of operating environment change(ex. from high to low temp.), it takes 30 sec torespond for CO2 sensor and 30 minutes for RH.3. Press “p/DP/WB” to switch temperaturesdisplay. The lower left display will cycle from airtemperature, dew point temp., and wet bulbtemp. (Fig. 2)4. Press “MNX/AVG/q” to see the minimum,maximum, and weighted average readings.Each press of it displays MIN, MAX, STEL, TWA insequence and returns to normal mode. In MIN andMAX modes, it shows the minimum and maximumreadings of CO2 on main display, and of AIR/DP/WBT temperatures and humidity on the lowerdisplays. In STEL and TWA modes, the main displayshows the weighted average of CO2 readings forthe past 15 minutes (STEL) and 8 hours(TWA), butthe lower displays are the current AIR, DP/WBtemperatures and humidity readings.NOTE:• If the meter is turned on for shorter than 15minutes, the STEL value will be the weightedaverage of readings taken since power on. Samefor TWA values appear before 8 hours.• It takes at least 5 minutes to calculate STEL andTWA. The display shows “----” during the first 5minutes from power on (Fig. 3).4Alarm OutputThe meter features visible and audible alarm to give warnings when CO2 concentration exceeds the limit. Users can set up 2 limits: An upper limit for alarm threshold that requires air conditioning and a lower limit to stop the alarm. (See P1.0 in setup for setting alarm limits).It emits beeps(Abt.80dB) with blinking LED when CO2 level goes over the upper limit. Beeps can be stoppedby pressing any key or automatically stops whenCO2 reading falls below lower limit. If the beeper is temporarily shut, it will sound again when readingsfall below lower limit and then go over the upper limit again, or users press “RESET” for more than 1 secondto activate it. LED alarm keeps blinking when beeps are manually shut. It stops only when readings fall under the lower limit.The meter is designed with a relay to send outputfor further connection. When CO2 readings go overthe upper limit and cause alarming. The relay picks up automatically and sends output. It can be connected to a ventilation system or activator for conditioning the air quality. The relay will drop out when CO2 readings fall under the lower limit.SetupThe advanced setup mode lets you customize your meter.3 types parameters are available.P1.0: CO2 AlarmP3.0: Temperature unitP4.0: ABC selectionP1.0 CO2 alarm: upper & lower limitsHold down “SET” under normal mode for more than 1 sec to enter set up mode. To exit setup, press “CAL/ESC” in P1.0, P3.0, or P4.0.5When entering setup mode, P1.0 and “AL” are displayed on the LCD (Fig. 4). Press “SET” again to go into P1.1 for setting CO2 upper limit. The current set value will be blinking on LCD (Fig.5). Press “p/DP/WB” to increase the value or “MNX/AVG/q”to decrease. Each press tunes 100 ppm and the alarm range is from 100 to 9900ppm. When the preferred value is set, press “SET” to go into P1.2 for lower limit setting. After both settings are done, press “SET” to save or “CAL/ESC” without saving and return to P1.0.P3.0: Temperature scalePress “p/DP/WB“ in P1.0 to access P3.0 for setting up temperature scale. Press “SET” and it goes into P3.1 with blinking °C or °F current set on the lower left display.To switch °C or °F, press “p/DP/WB “or “MNX/AVG/q”. Then press “SET” to save the setting or “CAL/ESC” without saving and return to P3.0.P4.0: ABC selectionPress “p/DP/WB“ in P3.0 or “MNX/AVG/q” in P1.0 to access P4.0 for selecting ABC function. Press “SET” and it goes into P4.1 with blinking “dis” default (Fig. 6) on the lower left display. To enable the ABC function, press “p/ DP/WB“ or “MNX/AVG/q” and “En” blinks for choice. After the preferred selection is done, press “SET” to save the setting or “CAL/ESC” without saving and return toP4.0.Calibration ModeCO2 calibrationABC (Automatic Baseline Calibration)ABC is to implement baseline calibration toeliminate the zero drift of the NDIR sensor. Itcalibrates the meter at the minimum CO2 readingdetected during 7 days continuous monitoring(power on). It’s not suitable to implement ABC inclose area with higher CO2 level all the time. TheABC default is off. To enable the function, pleaserefer to SETUP P4.0.6Manual calibrationThe manual calibration is suggested to be done inoutdoor area with ventilating fresh air where CO2level is around 400 ppm. Do not calibrate in placescrowded with people or close to where with highCO2 concentration such as ventilating outlets orfireplaces.1. Place the meter in the calibration site. Turn on themeter and hold down “CAL/ESC” and “p/DP/WB“simultaneously to enter CO2 calibration mode.400ppm and “CAL” are blinking on the LCD whileperforming calibration. (Fig. 7)2. Wait about 5 minutes until it stops blinking andthe calibration completes and back to normalmode.3. To abort the calibration, turn “RESET” over asecond.Humidity calibration1. Plug the sensor probe into 33% salt bottle. Holddown “CAL/ESC” and “MNX/AVG/q” undernormal mode to enter 33% calibration. “CAL” andcalibrating value (32.7% if at 25°C) are blinkingon the LCD with current temperature at the left.Meter is now calibrating, and will finish in about60 minutes when “CAL” and humidity value stopblinking.2. After 33% calibration, plug the sensor probe into75% salt bottle, then press “SET” to enter 75%calibration. “CAL” and calibrating value (75.2%if at 25°C) are blinking on the LCD with currenttemperature at the left. Meter is now calibrating.Wait about 60 minutes until blinking stops, thencalibration is completed and it returns to normalmode.73. Users can also calibrate either point. To calibrate33% only, press “CAL/ESC” to exit when 33%calibration is completed. To calibrate 75% only,press “p/DP/WB“ or “MNX/AVG/q” within 5minutes while initializing 33% calibration. And itskips 33% and enters 75% calibration.USB Interface CapabilitiesThe USB cable and software (optional kit) are required to transfer data to a PC. Install the USB driver in the software first before connection. And the connecting protocol is 9600 bps, 8 data bits, no parity.8� - EMC: Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC(Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results whenmaking measurements in the presence of electronic interference.9MAINTENANCEInstrument service personnel. The front panel andcase can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. TROUBLE SHOOTINGCan’t power on• Check whether the adaptor is well plugged.Slow response• Check whether air flow channels on the rear wereblocked.Error codeE01: CO2 sensor damaged.E02: The value is under range.E03: The value is over range.E04: The original data error results in this error(RH, DP, WB)E07: Too low voltage to measure CO2. Check if the adaptor output is 12V.E11: Retry humidity calibration.E17: Retry CO2 calibration.E31: Temperature sensor damaged.E34: Humidity sensor damaged.10APPENDIX - CO2 LEVELS AND GUIDELINESNIOSH recommendations250-350 ppm: normal outdoor ambient concentrations 600 ppm: minimal air quality complaints600-1000 ppm: less clearly interpreted1000 ppm: indicates inadequate ventilation; complaints such as headaches, fatigue, and eye/throat irritation will be more widespread. 1000 ppm should be used as an upper limit for indoor levels.ASHRAE Standard 62-1989: 1000ppmCO2 concentration in occupied building should not exceed 1000ppm.Building bulletin 101 (BB101): 1500ppmUK standards for schools say that CO2 at averaged over the whole day(i.e. 9am to 3.30pm) should not exceed 1500ppm.OSHA: 5000ppmTime weighted average over five 8-hour work days should not exceed 5000ppm.Germany, Japan, Australia, UK: 5000ppm8 hours weighted average in occupational exposure limit is 5000ppm.1112。
AC2说明书

1 简介在ZAPIMOS系列中,AC-2逆变器适用于3.0-8.0KW电机的控制,它们已被广泛用于电瓶牵引车的控制,如电动叉车、高尔夫车、小汽车的控制。
2 规格2.1 AC-2技术规格三相交流异步电机逆变器再生制动功能CAN总线接口瞬间存储器微处理器的数字控制电压:…………………………………………………………………………24-36-48-72-80-96V最大电流(24V 36V,):…………………………………………………500A,可持续时间3分钟最大电流(36V,48V):…………………………………………………450A,可持续时间3分钟最大电流(72V,80V)(*):………………………………………………400A,可持续时间3分钟最大电流(96V):………………………………………………………250A,可持续时间3分钟所有的型号都有调压器…………………………当电流超过最大电流10%时,可持续几秒钟工作频率:………………………………………………………………………………8kHZ环境温度:…………………………………………………………………………-30℃—40℃逆变器最高温度(在全功率):………………………………………………………………75℃2.2 连接图3 输入装置的说明3.1 微动开关-微动开关接触电阻必需小于0.1欧姆;漏电电流必需小于100μA-在满负载的情况下,电锁开关触点之间的电压降幅要低于0.1V-当功能请求(例如运行请求)有效时,微动开关就向微处理器传送电压信号3.2 加速单元加速单元可以由一个电位器或者一个霍尔电路组成。
它由3线配置,电位器电源通过CNE#2接入。
电位器输出信号接入CPOT(CNE#),信号范围为0—10V。
电位器负端接入CNE#3.电位器的阻值范围应为0.5——10Ω负载范围一般是1.5-30mA,超出了这个范围就会出现故障。
电位器信号自动获得功能可使用手持单元实现,有用信号的最小和最大水平的调节可在两个方向上进行。
流式细胞仪操作规程-SOP

流式细胞仪操作规程目录
1:淋巴细胞亚群测定及绝对计数
2:活化淋巴细胞亚群、记忆T及纯真T的检测
3:HLA-B27测定
4:CD55/CD59测定
5:干细胞检测和绝对计数
6:白血病免疫分型测定
7:淋巴细胞T细胞亚群细胞内因子IFN-γ/IL-4测定8:细胞周期分析
9:活化血小板检测
10:血小板抗体测定
11:红细胞抗体测定
12:粒细胞抗体测定
淋巴细胞亚群测定
(流式细胞仪)
医院检验科
操作规程文件号:
200 年月日起实施
第1版
(共3页)
本规程每2年复审一次
复审日期:年月日
复审人:
规程编写者:
审批者:
批准日期:年月日
文件分发部门和/或个人
院档案室保管者:
检验科主任:
检验科实验室:
淋巴细胞亚群测定
点击
点击
3色
点击
(命名,点击save)画图
此图为CD45圈门
填写Flow-Count的浓度
活化淋巴细胞亚群、记忆T及纯真T的测定
HLA-B27测定
点击
点击
X-Mean=17.1 negative(-)
X-Mean=1.2 X-Mean=5.8
CD55/CD59测定
2.RBC: abnormal
干细胞检测和绝对计数
白血病免疫分型测定
T细胞亚群细胞内因子IFN-γ/IL-4检测
细胞周期分析
2.画图
血小板膜表面抗体测定
红细胞膜蛋白结构测定(红细胞抗体)
粒细胞抗体测定。
SPAD502叶绿素仪操作手册.doc

SPAD502叶绿素仪操作手册一、仪器介绍测量头读数校验卡二、屏幕介绍1、N表示存储在机器内的数据个数;No表示当前数据序号。
2、低电显示,出现这个图标表示电池电量已耗尽或者电池应该更换3、表示当前显示的值为平均值4、测定数值或操作信息举例:1、下面屏幕表示:第26个数据,其测量值为32.7。
2、若数值小于100,显示小数点后1位,当数值大于100或接近100时,无小数点显示。
当数值大于50后,小数点会闪烁,表示这个数值不能保证十分精确。
3、当按了“平均”以后,显示的为当前数值的平均值4、当按了“浏览数据”后,显示以前存储数据。
5、当校准时出现上面此图标表示探测头没有正确关闭;当环境温度变化10度以上,此图标出现,表示要重新校准,一旦重现校准,所存储的数据都将被删除。
出现(1)图示,说明透射光过量,需要重新校准。
出现(2)图示,说明透射光不足,需要清洁测量头的发射窗和接收窗,然后重新校准。
如果清洁后仍继续出现此图示,有可能是出现故障了。
6、出现此图示,说明测量头没有完全关闭,重新测量。
如果一直显示此图示,有可能出现故障了。
7、出现此图示,说明透射光不足,需要清洁测量头的发射窗和接收窗,如果仍出现此图示,有可能此样品不能测量。
8、出现此图示,说明电量不足,需更换电池。
9、出现此图示,说明仪器工作不正常,将开关打到关,然后再打开,如果仍出现此图示,说明仪器坏了,需要修理。
三、电池的安装:拧开SPAD502下部的电池盒盖,正极向里安装2节AA电池;再拧上盖。
可以使用碱性电池和碳锌电池,不能使有性质不同或电量不同的电池。
四、仪器的校准:每次开机都需校准,请遵照以下程序进行1)打开电源2)不放样品,按下探测头,直到听到“哔”一声,屏幕显示N=0 ―――表明校准完成。
3)如果持续蜂鸣,出现下面图示,表示校准未正确完成,按2)重复进行校准。
如果出现下面图示,则发射窗或接收窗需要清洁,清洁后按2)重新校准。
五、测量在野外,SPAD502使用非常便捷。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
编 制CALCULATED BY DATE 校 对审 核REVIEWED BY DATE编写说明为保证烟气余热换热器安全、稳定、可靠的运行,本说明书对换热器运行中的主要部件及辅助设备的操作、使用方法、监督、应注意事项等作了原则性的说明。
由于烟气余热换热器与机组的启动、停炉及其他各种辅机设备、控制系统等密切有关,因而最终的用户应根据本说明书的要求以及其它设备、DCS系统操作使用要求及国家和行业的有关标准编写完整的锅炉操作运行规程。
本说明书仅供用户在编制机组运行规程和启动调节细则时作参考。
烟气余热换热器启动前,应根据设计文件及有关规程制定符合设计、设备特点的启动试运行调整方案及措施。
目录一、烟气余热换热器的启动 (4)1.启动前的检查 (4)2.烟气余热换热器启动前的准备 (4)3.烟气余热换热器上水 (4)4.烟气余热换热器的启动过程 (5)二、烟气余热换热器的正常运行 (5)1.正常运行 (5)2.烟气余热换热器运行的控制与调节 (5)三、烟气余热换热器停运 (6)1.停运方式 (6)2.停运前的准备 (6)3.正常停运 (7)四、烟气余热换热器的保养和防冻 (8)1.烟气余热换热器的保养 (8)2.烟气余热换热器的防冻 (8)五、吹灰系统 (8)一、 烟气余热换热器的启动由于烟气余热换热器只是整个系统的一部分,所有设备必须协调工作,对于新装的设备,由于性能还不完全掌握和缺乏操作经验,启动时更应十分谨慎。
1.启动前的检查烟气余热换热器在启动前,有关运行人员应对锅炉设备进行全面的检查并做好启动前的准备工作,主要检查内容如下:(1) 确信所有的安装工作均已完成,换热器内所有的工具和残渣等已经清除,手孔门和人孔门已经安装和关闭,所有的检修门已安装和关闭。
(2) 检查并消除烟气余热换热器各部位任何有碍膨胀的故障,清除周围杂物和垃圾,保证畅通。
(3) 检查所有的阀门是否处于启动的正确位置,阀门没有泄漏,开关灵活,开度指示与实际位置应相符。
(4) 各汽水管道支吊架完整,受力均匀,已处于正常工作状态。
(5) 检查所有控制系统、热工仪表等均处于正常工作状态。
2.烟气余热换热器启动前的准备(1) 在允许凝结水到烟气余热换热器之前,换热器所有的辅助设备应已联结可以运行并确认。
所有仪表阀门应联结能使用。
(2) 换热器本体部分的疏水阀、排污阀已关闭,放气阀已打开。
3.烟气余热换热器上水(1) 烟气换热器上水,打开管道上放空气阀及给水管路上的进水阀,其它阀门开关应处于允许烟气余热换热器充水的位置,给水流经进口汇集集箱,各进口小集箱,受热面,各出口小集箱,出口汇集集箱,出水阀关闭。
待最高处的放气阀有水溢出时,关闭放气阀,打开出水阀,换热器可正常进水。
(2) 严格控制进水温度,水温不宜过低或过高,使水温与管子壁温之间的温差尽量小且必须低于55°C,调节给水控制阀的开度,以控制上水流量。
上水速度不宜过快。
(3) 上水期间加强检查集箱的手孔盖以及各部位的阀门、堵头等是否有泄漏现象。
若发现漏水,立即停止上水并进行处理。
(4) 上水结束后进行炉水品质分析化验,合格后方可运行。
4.烟气余热换热器的启动过程(1) 烟气经过除尘器后进入烟气换热器烟道,随着烟气流量、温度增加,烟气换热器开始升温、升压。
升压的速度不宜过快,尤其是新装锅炉,避免突然的热膨胀或各部位因受热不均匀而产生过大的热应力,损坏烟气换热器部件,影响烟气换热器使用寿命,从开始升压至达到工作压力的时间不得小于1小时。
升压过程中必须密切注意烟气换热器水量的变化,以维持正常水量。
(2) 当压力上升到O.2~0.3MPa时应进行下列工作:①对新装或检修后的烟气换热器,为防止因受热膨胀导致螺栓松动,接合面泄漏应对人孔盖、法兰连接螺栓拧紧一次。
操作时应侧身,不宜用力过猛;选用紧固的板手。
长度不得超过螺栓直径的15倍~20倍,防止拧断螺栓。
②试用给水设备和排污装置。
对集箱全面排污放水一次,放水后启动给水设备进水,保持水量正常,并检查各排污阀、放水阀是否有漏水现象。
(3) 在升压过程中应随时监视炉水品质,应符合 GB1576《工业锅炉水质》标准的规定。
(4) 冬季启动时,作好锅炉各部件及仪表管的防冻工作。
二、 烟气余热换热器的正常运行1.正常运行(1) 压力表每年至少校验一次, 压力表弯管必须定期冲洗。
(2) 定期检查水泵等运转情况,及时消除故障。
(3) 排污:定期排污是为了排除集箱内的沉淀物,并能调整给水品质使其达到要求。
2.烟气余热换热器运行的控制与调节烟气换热器运行参数的稳定与外界负荷的变化和烟气换热器内部因素的改变有着密切的关系。
只要上述因素中任何一个变动,均会影响烟气换热器运行的稳定及安全性,因此,必须对烟气换热器进行一系列的控制和调节,使烟气换热器的参数与外界的变动或内因的改变相适应,从而达到安全和经济的运行。
烟气换热器运行时,必须控制压力、水温、水量在允许的范围内波动,以确保炉安全经济,满足需要。
(1) 压力的控制烟气换热器运行时,应保持水压稳定。
当烟气换热器水压低于规定的工作压力时,不能满足生产工艺的要求;当烟气换热器压力超过规定的最高允许工作压力时,则将造成超压事故。
烟气换热器水压变化的原因如下:①外界负荷的变化。
主要反映的是烟气余热换热器热功率与外界热负荷之间的矛盾。
烟气余热换热器在运行时,受热面内产生的热水不断进入出口集箱空间又不断离开,送离设备。
当受热面流入出口集箱的热水多于外界需求时,烟气余热换热器的水压就会上升;反之,烟气余热换热器的水压就会下降。
②烟气余热换热器进口烟气量和烟温的变化,将导致烟气余热换热器热功率的变化。
(2)烟气余热换热器水量的控制烟气余热换热器采用连续进水,水泵不停,采用开大或关小给水调节阀来控制进水量多少,以维持正常给水量适应于烟气余热换热器负荷所需要的出水量。
三、 烟气余热换热器停运1.停运方式停运是由各种原因造成的,有预先计划的,也有因机组的缺陷和事故被迫停运。
所以停运的方式一般有两种情况,正常停运和紧急停运。
正常停运又可分为两种,停运至冷备用和停运至热备用。
因此实际有三种停运方式。
停运至冷备用,指烟气余热换热器停运之后,一直冷却至常温备用或检修。
停运至热备用,指烟气余热换热器停运之后,尽量防止热量的损失,以便在较短的时间内重新启动。
紧急停运一般是烟气换热器发生了重大事故或有事故预兆时,为了避免事故的扩大而采取的紧急措施。
2.停运前的准备与启动一样,停运也存在着安全和经济两方面的问题,因而运行人员应在了解停运目的以后,确定停运方式,并做好停运前的准备。
(1) 检查各自动调节系统,确认其状态。
(2) 停运前应对烟气余热换热器本体进行一次全面检查,对运行中不能消除的设备缺陷,作详细的记录。
3.正常停运(1) 停运至冷备用①不应有烟气流向烟气换热器。
②关闭主供水阀停止供水,同时关闭排污阀。
③停运后烟气换热器应缓慢冷却,压力降不可以太快,待压力降低到O.02MPa时,可开启空气阀,在蒸汽冷凝过程中,由空气阀吸入空气,防止烟气余热换热器内产生真空。
④停运0~6 h后,逐渐开启烟道挡板通风。
停炉8~10h后,若需加速冷却时,可采用放水和上水来降温,停炉18~24h后,水温度低于70℃时,方可将锅水全部放出。
(2) 停运到热备用①不应有烟气流向烟气余热换热器;②将烟气换热器所有的阀门按照停运到热备用所要求的调好,特别确保下列阀门是关闭的:给水隔离阀、出水隔离阀、所有的放气阀和疏水阀③如果有烟道挡板,关闭换热器出口烟道挡板以保持换热器的温度。
尽量防止热量的损失,以便在较短的时间内重新启动。
(3) 紧急停运1)遇到下列情况之时,应紧急停运。
①给水泵全部失效或给水系统故障,不能向烟气换热器进水。
②烟气换热器元件损坏,危及运行人员安全。
③其它运行异常情况危及锅炉安全运行。
2)紧急停运的操作针对烟气余热换热器发生事故的性质不同,紧急停运的操作也各不相同①停止供入烟气。
关闭出水阀。
②所有自动切换为手动操作。
③注意保持水位,停止排水。
④缺水事故紧急停运时,严禁向烟气余热换热器进水,也不准开启空气阀等加强向外排汽的操作,以防烟气余热换热器受到突然的温度或压力变化而将事故扩大。
⑤爆管事故紧急停运时,应尽快排出烟道内烟气,若水位能维持时,应保持进水或采用进水、放水法迅速冷却减压。
3)停运时应注意事项①停运操作中要加强监视压力、水量变化。
水压不能下降太快,水压未降到大气压力时,应对烟气余热换热器加以监视,运行人员应加强检查,并使烟气余热换热器水量保持最高允许水量。
若发现水压仍在上升可采用向烟气余热换热器上水,并同时放水的方法来降温降压。
②停运放水后,应将出水、给水、排污等管路与其它并水运行的烟气余热换热器用堵板(育板)全部隔绝,方可进入烟气余热换热器内工作。
四、 烟气余热换热器的保养和防冻1.烟气余热换热器的保养烟气余热换热器停运后,不论是备用还是检修均应认真执行防腐工作。
(1) 运行设备作短期备用(一般不超过一周),承压部件又无检修工作,并且准备随时启动时大都采用“压力保养法”。
(2) 运行设备大修、小修或超过十天,不超过一个月,一般采用“湿法保养”。
(3) 运行设备转为一个月以上的较长时间备用时,应采取“干法保养”,(4) 对长期停用的烟气余热换热器,可采用“充气法(充氨或充氮)”进行保养。
根据保养的原则来选定保养的方法。
如何进行操作,可根据具体情况参照有关规程进行保养和操作。
2.烟气余热换热器的防冻进入冬季前应全面检查防冻措施,不能有裸露的管道,将管道、本体各防冻加热装置投入运行。
仪表管内积水应放尽。
烟气余热换热器的各孔门及挡板应关闭。
处于检修状态的烟气余热换热器应有防止冷风吹入的措施。
烟气余热换热器在冬季停用应尽可能采用干法保养。
五、 吹灰系统本项目烟气余热换热器采用蒸汽吹灰,其操作说明请严格按照蒸汽吹灰器厂家提供的说明执行。