Eaton 167815
Eaton Moeller® series MSC-DE DOL starter, Ir= 1 - 4 A, 24 V
50/60 Hz, AC voltage
General specifications
Eaton Moeller® series MSC-DE DOL
starter
167815
4015081643936
145 mm272 mm
45 mm 1.174 kg
UL File No.: E123500
UL
CE
IEC/EN 60947-4-1
CSA Class No.: 3211-08
UL60947-4-1A
VDE 0660
CSA-C22.2 No. 14-10
UL Category Control No.: NKJH CSA
CSA File No.: 012528MSC-DE-4-M17-SP(24V50/60HZ)
Product Name Catalog Number
EAN
Product Length/Depth Product Height Product Width Product Weight Certifications Model Code
Short-circuit release
Temperature compensated overload protection Adjustable
Screw terminals
No
500 (Class 5) AC-4 cycle operation, Main conducting paths Note: Going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
700 (Class 10) AC-4 cycle operation, Main conducting paths 900 (Class 15) AC-4 cycle operation, Main conducting paths 1000 (Class 20) AC-4 cycle operation, Main conducting paths
≤ 500 ms, main conducting paths, AC-4 cycle operation
IP20
NEMA Other
Direct starter
DIN rail
1
1 A
4 A
III
Fitted with: Functions Class
Connection
Connection to SmartWire-DT
Current flow times - min
Cut-out periods - min
Degree of protection
Model
Mounting method
Number of auxiliary contacts (normally closed contacts) Number of auxiliary contacts (normally open contacts) Overload release current setting - min
Overload release current setting - max
Overvoltage category
Pollution degree
3
6000 V AC
Starter with electronic trip unit AC Max. 2000 m -25 °C
55 °C
16.7 A
4 A
0.75 kW
7.5 kW
208 - 600 V AC
1 A, 250 V DC, (UL/CSA)
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA) A600, AC operated (UL/CSA)0 A
18 kA, 480 Y/277 V, SCCR (UL/CSA) 18 kA, 240 V, SCCR (UL/CSA)
186 A
2.1 CO, Coil in a cold state and 1.0 x Us
24 V
24 V
24 V
24 V
0 V
0 V
Rated impulse withstand voltage (Uimp)
Type Voltage type Altitude
Ambient operating temperature - min Ambient operating temperature - max
Rated operational current (Ie)
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V Rated operational power at AC-3, 220/230 V, 50 Hz
Rated operational power at AC-3, 380/400 V, 50 Hz
Rated operational voltage
Switching capacity (auxiliary contacts, general use) Switching capacity (auxiliary contacts, pilot duty)Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V
Short-circuit current rating (type E)
Short-circuit release (Irm) - max
Power consumption, sealing, 50 Hz
Rated control supply voltage (Us) at AC, 50 Hz - min
Rated control supply voltage (Us) at AC, 50 Hz - max
Rated control supply voltage (Us) at AC, 60 Hz - min
Rated control supply voltage (Us) at AC, 60 Hz - max
Rated control supply voltage (Us) at DC - min
Rated control supply voltage (Us) at DC - max
0.75 HP 0.75 HP 2 HP 1.5 W
0 W
0.5 W
4 A
2.1 W
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Does not apply, since the entire switchgear needs to be evaluated.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Assigned motor power at 200/208 V, 60 Hz, 3-phase Assigned motor power at 230/240 V, 60 Hz, 3-phase Assigned motor power at 460/480 V, 60 Hz, 3-phase Equipment heat dissipation, current-dependent Pvid
Heat dissipation capacity Pdiss
Heat dissipation per pole, current-dependent Pvid
Rated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs
10.2.2 Corrosion resistance
10.2.3.1 Verification of thermal stability of enclosures
10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
10.2.4 Resistance to ultra-violet (UV) radiation
10.2.5 Lifting
10.2.6 Mechanical impact
10.2.7 Inscriptions
10.3 Degree of protection of assemblies
10.4 Clearances and creepage distances
10.5 Protection against electric shock
10.6 Incorporation of switching devices and components
Eaton Corporation plc Eaton House
30 Pembroke Road Dublin 4, Ireland
© 2023 Eaton. All rights reserved. Eaton is a registered trademark.
All other trademarks are
property of their respective owners.
/socialmedia
Does not apply, since the entire switchgear needs to be evaluated.
Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.
Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Simple, flexible and safe! Distribution system for motor-starter combinations
Save time and space thanks to the new link module PKZM0-XDM32ME Motor Starters in System xStart - brochure Product Range Catalog Switching and protecting motors DA-DC-00004109.pdf DA-DC-00004245.pdf eaton-manual-motor-starters-msc-d-dol-starter-dimensions.eps
eaton-manual-motor-starters-mounting-msc-d-dol-starter-3d-drawing.eps eaton-manual-motor-starters-msc-d-dol-starter-3d-drawing.eps DA-CE-ETN.MSC-DE-4-M17-SP(24V50_60HZ)
IL03402052Z
WIN-WIN with push-in technology DA-CD-msc_de_sp DA-CS-msc_de_sp eaton-manual-motor-starters-device-msc-d-dol-starter-wiring-diagram.eps 10.7 Internal electrical circuits and connections 10.8 Connections for external conductors 10.9.2 Power-frequency electric strength 10.9.3 Impulse withstand voltage 10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise
10.11 Short-circuit rating
10.12 Electromagnetic compatibility
10.13 Mechanical function
Brochures
Catalogues
Certification reports Drawings
eCAD model
Installation instructions
Installation videos
mCAD model Wiring diagrams。