Eaton 177368
Eaton DE1 Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 5 A, 2.2 kW, 3 HP
General specifications
Eaton DE1 Variable speed starter 177368DE1-345D0NN-N20N 4015081718283169 mm 230 mm 90 mm 1.6 kg UL File No.: E172143
UL Category Control No.: NMMS, NMMS7 UL CE UL 508C IEC/EN61800-5 CUL
RoHS, ISO 9001
UL report applies to both US and Canada
Specification for general requirements: IEC/EN 61800-2 RCM
Safety requirements: IEC/EN 61800-5-1 Certified by UL for use in Canada IEC/EN 61800-3 CSA-C22.2 No. 14 IEC/EN61800-3
Overload cycle for 60 s every 600 s
Product Name
Catalog Number Model Code
EAN
Product Length/Depth Product Height Product Width Product Weight Certifications
Catalog Notes
Parameterization: drivesConnect Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus Parameterization: Keypad
PC connection C3 ≤ 25 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
OP-Bus (RS485), built in
In conjunction with DX-NET-SWD3 SmartWire DT module
Yes
IP20
NEMA Other
1st and 2nd environments (according to EN 61800-3)
FS2
Variable speed starter
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
MODBUS
EtherNet/IP
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms
Branch circuits, (UL/CSA)
Features Fitted with:Cable length Communication interface Connection to SmartWire-DT Degree of protection Electromagnetic compatibility Frame size
Product category Protection
Protocol
Radio interference class
Shock resistance
Suitable for
Vibration
Resistance: According to EN 61800-5-1
Max. 2000 m
Above 1000 m with 1 % derating per 100 m
-10 °C
60 °C
-10 °C
60 °C
-40 °C
70 °C
< 95 average relative humidity (RH), no condensation, no
corrosion
7 A
< 3.5 mA (AC-operated)
< 10 mA (DC-operated)
Maximum of one time every 30 seconds 380 V
480 V
Speed control with slip compensation U/f control 4.8 A
5 A
5 A
4.8 A
3 HP
3 HP
Altitude
Ambient operating temperature - min
Ambient operating temperature - max
Ambient operating temperature at 150% overload - min Ambient operating temperature at 150% overload - max Ambient storage temperature - min
Ambient storage temperature - max
Climatic proofing
Input current ILN at 150% overload Leakage current at ground IPE - max Mains switch-on frequency
Mains voltage - min
Mains voltage - max
Operating mode
Output frequency - min Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload Assigned motor current IM at 230 V, 50 Hz, 150% overload Assigned motor current IM at 400 V, 50 Hz, 150% overload Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload Assigned motor power at 230/240 V, 60 Hz, 1-phase
Assigned motor power at 460/480 V, 60 Hz, 3-phase
0 Hz
300 Hz
400 V AC, 3-phase
480 V AC, 3-phase
7.5 A
10 V DC (Us, max. 0.2 mA)
45 Hz
66 Hz
5 A at 150% overload (at an operating frequency of 1
6 kHz and an ambient air temperature of +50 °C)
2.2 kW
400 V AC, 3-phase
480 V AC, 3-phase
0.025 Hz (Frequency resolution, setpoint value)
15 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
200 %, IH, max. starting current (High Overload), For 1.875 seconds every 600 seconds, Power section
50/60 Hz
16 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
480 V 3.46 kVA
4.16 kVA
Adjustable to 100 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
1 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)
4 (parameterizable, 10 - 30 V DC)
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
65 W
0 W
0 W
5 A
0 W
Operation (with 150 % overload)
Output frequency - max
Output voltage (U2)
Overload current IL at 150% overload
Rated control supply voltage
Rated frequency - min
Rated frequency - max
Rated operational current (Ie)
Rated operational power at 380/400 V, 50 Hz, 3-phase Rated operational voltage
Resolution
Short-circuit protection rating
Starting current - max
Supply frequency
Switching frequency
Voltage rating - max Apparent power at 400 V
Apparent power at 480 V
Braking torque
Number of inputs (analog)
Number of inputs (digital)
Number of outputs (analog)
Number of outputs (digital)
Number of relay outputs
Equipment heat dissipation, current-dependent Pvid
Heat dissipation capacity Pdiss
Heat dissipation per pole, current-dependent Pvid
Rated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs
Heat dissipation details
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Does not apply, since the entire switchgear needs to be evaluated.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Meets the product standard's requirements.
Does not apply, since the entire switchgear needs to be evaluated.
Does not apply, since the entire switchgear needs to be evaluated.
Is the panel builder's responsibility.
Is the panel builder's responsibility.
Is the panel builder's responsibility.
Is the panel builder's responsibility.The OP System Bus - Parameterizing - Control
Fire mode
Start, Stopp und Betrieb
Quick-Start-Guide DE1 (english)
Conformal Coating
How does the internal motor protection work?
DX-COM-STICK3_Connection
Update DX-COM-STICK3
Set point setting
Starting, Stopping and Operation
Electromagnetic compatibility (EMC)
Motor data Motor Protection V/f curves Slip Compensation
I/O Configuration
Connecting drives to generator supplies
Access to Parameter Level 2 Parameter Lock Load Default Quick-Start-Guide DE11 (english)
HVAC, water/wastewater and industrial mediums - brochure Number 1 in efficiency The easiest way of variable motor speed PowerXL DE1 Variable Speed Starter
DA-SW-Codesys 3 SWD for DC1 and DE1
DA-SW-USB Driver DX-COM-STICK3-KIT
DA-SW-drivesConnect
DA-SW-drivesConnect - installation help
DA-SW-DE1 ModbusRTU V1_00 Library
DA-SW-drivesConnect - Installationshilfe
DA-SW-Codesys 2 SWD for DC1 and DE1
DA-SW-Driver DX-CBL-PC-3M0
DA-SW-drivesConnect USB Driver DX-COM-PCKIT
DA-SW-USB Driver PC Cable DX-CBL-PC-1M5
Product Range Catalog Drives Engineering
Drives - Product range catalog
DA-DC-00004551.pdf
DA-DC-00004556.pdf
10.2.2 Corrosion resistance
10.2.3.1 Verification of thermal stability of enclosures
10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
10.2.4 Resistance to ultra-violet (UV) radiation
10.2.5 Lifting
10.2.6 Mechanical impact
10.2.7 Inscriptions
10.3 Degree of protection of assemblies
10.4 Clearances and creepage distances
10.5 Protection against electric shock
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors
10.9.2 Power-frequency electric strength
10.9.3 Impulse withstand voltage Application notes Brochures
Catalogues Certification reports
Eaton Corporation plc Eaton House
30 Pembroke Road Dublin 4, Ireland
© 2023 Eaton. All rights reserved. Eaton is a registered trademark.
All other trademarks are
property of their respective
owners.
/socialmedia
Is the panel builder's responsibility.
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.eaton-frequency-inverter-dimensions-010.eps eaton-frequency-inverter-3d-drawing-018.eps
DA-CE-ETN.DE1-345D0NN-N20N
IL040005ZU
PowerXL DE1 variable speed starter
MN040003_EN
MN040018_EN
MZ040046_EN
MN040011_EN
DA-CS-de1_fs2_ip20
DA-CD-de1_fs2_ip20
10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise
10.11 Short-circuit rating
10.12 Electromagnetic compatibility
10.13 Mechanical function Drawings
eCAD model Installation instructions Installation videos Manuals and user guides
mCAD model。