FeaturesSmall size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life.Suitable for automobile, machine, electronic equipment, air conditioner and household appliance applications.PC board mounting.Ordering InformationNT90 R H A S DC12V C B 0.91 2 3 4 5 6 7 8 91 Part number :NT90T 、NT90T 22 Terminal : R: without Pin 6;NIL: With Pin 63 Load :H:30A ;N:40A4 Contact arrangement :1A:1A ;1B:1B ;1C:1C5 Enclosure :S: Sealed type ;D: Dust cover ;E: Covered ;O: Open type6 Coil rated Voltage(V):AC:12,24,110,120,220DC:3,5,6,9,12,15,18,24,48,1107 Contact material :C: Ag CdO ;S: Ag SnO 28 Resist heat class :B:130℃ F:155℃9 Coil power consumption :0.6:0.6W ;0.9:0.9W NIL:2VA Contact DataContact Arrangement1A SPSTNO f 1B(SPSTNC)f 1C(SPDT(B-M))Contact MaterialAg CdO Ag SnO 2 Ag SnO 2 In 2O 3Contact Rating (resistive)NO : 30A/240VAC,14VDC; NC:20A/240VAC ;30A/14VDC NO :40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W)Motor load :2HP 250VAC ;1.5HP 250V Lamp load :TV-5Max. Switching Power1100W 7200VA Max. Switching Voltage110VDC 250VAC Max. Switching Current:40A Contact Resistance or Voltage drop አ30m Item 3.12 of IEC255-7Electrical 105Item 3.30 of IEC255-7Operation life Mechanical107Item 3.31 of IEC255-7Coil ParameterAC Coil ParameterRATED VOLTAGEVACDASH NUMBERSRATEDMaxCOIL RESISTANCE ±10%PICK UP VOLTAGE VAC(max)(75%of rated voltage)RELEASE VOLTAGE VAC(min)(30%of rated voltage)COIL POWEROperate Time ms Release Time ms012AC 1215.6279.0 3.6024AC 2431.212018.07.2110AC 110143236082.533.0120AC 120156304090.036.0220AC22028613490165.066.02VA __CAUTION : 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.10330.5×24.2×17 32.5×27.6×20.5 99312549.2 01311661.4元器件交易网003-9003 3.9102.250.3005-9005 6.5283.750.5006-90067.8404.500.6009-900911.790 6.750.9012-9001215.61609.00 1.2015-9001519.525010.25 1.5018-9001823.436013.50 1.8024-9002431.264018.00 2.4048-9004862.4256036.00 4.8110-9001101431344582.5011.00.91510003-6003 3.915 2.250.3005-6005 6.542 3.750.5006-60067.860 4.500.6009-600911.7135 6.750.9012-6001215.62409.00 1.2015-6001519.537510.25 1.5018-6001823.454013.50 1.8024-6002431.296018.00 2.4048-6004862.4384036.00 4.8110-6001101432016782.5011.00.61510CAUTION : 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.Qualification inspection:Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.Operation conditionInsulation Resistance 1000M min (at 500VDC)Item 7 of IEC255-5Dielectric Strength Between contactsBetween contact and coil 50Hz 1500V 50Hz 2500V 4000V without Pin 6 Item 6 of IEC255-5Item 6 of IEC255-5Shock resistance 200m/s 2 11msIEC68-2-27 Test Ea Vibration resistance 10~55Hz double amplitude 1.5mm IEC68-2-6 Test Fc Terminals strength 10NIEC68-2-21 Test Ua1Solderability235 x 2 3x 0.5s IEC68-2-20 Test Ta method 1Ambient Temperature -55~100 -55~125 Relative Humidity 85% (at 40 )IEC68-2-3 Test CaMass27g Open type 30g元器件交易网。
NT78US10DC9V0.8中文资料
元器件交易网
Features
Small size, light weight. Low coil consumption. PC board mounting. Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities.
Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical
Coil Parameter
Coil voltage VDC Pickup voltage VDC(max) (80%of rated voltage ) 4.8 7.2 9.6 19.2 4.8 7.2 9.6 19.2 release voltage VDC(min) (5% of rated voltage) 0.30 0.45 0.60 1.20 0.30 0.45 0.60 1.20 0.8 10 5 0.6 10 5
Safety approvals Safety approval Load
UL NO 20A/14VDC 10A/120VAC NC 10A/14VDC 1/2HP 125VAC TV-5
CCEE 5A/250VAC
Dimensions (Unit: mm)
mm 0.4 0.5 1.1 1.3 1.4 1.45 2.5 3.5 5.0 10.2 12.3 14 15.7
S-T S-N S-V产品对照表
220-240V 2.5/11 380-440V 4/9 100-240V 20 额定(A) AC-1 (阻性负载) 380-440V 11 20 约定发热电流(A) 1a or 1b 辅助触头构成 W (宽) 43(*) H (高) 78(*) 外形尺寸(㎜) D (深) 78 E×F (安装) 35×50(*)
5.5/22 (*) 11/22 32 32 32 2a2b 63 81 81 54×60
(*)
7.5/30 15/30 50(*) (*) 50 50(*) 2a2b 75(*) 89(*) 91(*) 65×70(*)
注. 带(*)标记表示代替型号的额定值和规格有不同。
2.S-T C与S-V对照
79 81(*) 30×60(*)
5.5/22 5.5/22 (*) (*) 11/22 11/22 (*) 32 32 (*) 32 32 32 32(*) 1a1b or 2a 1a1b or 2a(*) 63 63(*) (*) 81 81 (*) 81 81 54×60 54×60(*)
(*)
额定(kw/A) AC-3 (电机负载)
1a or 1b(*) 1a or 1b(*) 43 43 78(*) 78 35×50 78(*) 78 35×50
7.5/32(*) (*) 11/25 15/32(*) 32 32 32 32 32 32 2a2b 63 81 81 54×60Fra bibliotekH F
W
注2.安装互换性 ○:可以互换 ×:不可互换
(*)
S-T25 7.5/30 15/30 32 32 32 2a2b 63 81 81 54×60 ×/○ S-N25
(电机负载)
S-N25
NMB24-3 商品说明书
NMB24-3FootnotesBasic Non Fail-Safe actuator for controlling dampers in typical commercial HVAC applications.• Torque motor 90 in-lb [10 Nm]• Nominal voltage AC/DC 24 V • Control On/Off, Floating pointTechnical dataElectrical dataNominal voltageAC/DC 24 V Nominal voltage frequency 50/60 HzNominal voltage rangeAC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 2 W Power consumption in rest position 0.2 W Transformer sizing 4 VAOverload Protectionelectronic throughout 0...95° rotation Functional dataTorque motor90 in-lb [10 Nm]Direction of motion motor selectable with switch 0/1Manual override external push button Angle of rotation Max. 95°Angle of rotation note adjustable with mechanical stop Running Time (Motor)95 s / 90°Running time motor note constant, independent of load Noise level, motor 45 dB(A)Position indicationMechanical, 30...65 mm stroke Safety dataPower source ULClass 2 Supply Degree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2Enclosure UL Enclosure Type 2Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02CE acc. to 2014/30/EU and 2014/35/EU Quality Standard ISO 9001UL 2043 CompliantSuitable for use in air plenums per Section 300.22(C) of the NEC and Section 602 of the IMCAmbient humidity Max. 95% RH, non-condensing Ambient temperature -22...122°F [-30...50°C]Storage temperature -40...176°F [-40...80°C]Servicingmaintenance-free Weight Weight2.9 lb [0.94 kg]MaterialsHousing material UL94-5VA†Rated Impulse Voltage 800V, Type action 1, Control Pollution Degree 3.NMB24-3ApplicationOperationTypical specificationProduct featuresFor on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications.The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft.The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement.The NMB(X) series provides 95° of rotation and a visual indicator indicates position of theactuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover.The NMB(X)24-3… actuators use a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode.Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions.Floating point, on/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05”diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. If required, actuators will be provided with a screw terminal strip for electricalconnections (NMX24-3-T). Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo.AccessoriesElectrical accessoriesDescriptionType Battery backup system, for non-spring return models NSV24 US Battery, 12 V, 1.2 Ah (two required)NSV-BAT Auxiliary switch 1 x SPDT add-on S1A Auxiliary switch 2 x SPDT add-onS2AFeedback potentiometer 140 Ω add-on, grey P140A GR Feedback potentiometer 1 kΩ add-on, grey P1000A GR Feedback potentiometer 10 kΩ add-on, grey P10000A GR Feedback potentiometer 2.8 kΩ add-on, grey P2800A GR Feedback potentiometer 500 Ω add-on, grey P500A GR Feedback potentiometer 5 kΩ add-on, greyP5000A GR Mechanical accessoriesDescriptionType Shaft clamp reversible, clamping range ø8...20 mm K-NA Mounting bracket for AF..ZG-100Mounting bracket ZG-101Mounting bracket ZG-103Mounting bracketZG-104Mounting kit for linkage operation for flat installationZG-NMA Shaft extension 240 mm ø20 mm for damper shaft ø8...22.7 mm AV8-25Shaft extension for 1/2" diameter shafts (3.8" L).ZG-NMSA-1Weather shield 13x8x6" [330x203x152 mm] (LxWxH)ZS-100Weather shield 406x213x102 mm [16x8-3/8x4"] (LxWxH)ZS-150Wrench 0.32 in and 0.39 in [8 mm and 10 mm]TOOL-06Linkage kitJackshaft Retrofit Linkage with Belimo Rotary ActuatorsZG-JSLElectrical installationActuators with appliance cables are numbered.Provide overload protection and disconnect as required.NMB24-3Actuators may also be powered by DC 24 V.Actuators Hot wire must be connected to the control board common. Only connect common toneg. (-) leg of control circuits. Terminal models (-T) have no-feedback.Actuators may be connected in parallel if not mechanically linked. Power consumption andinput impedance must be observed.Floating Point - Triac SourceWiring diagramsOn/Off Floating PointFloating Point - Triac Source Floating Point - Triac SinkNMB24-3 Dimensions。
NXS系列伟肯变频器基本参数
NXS系列伟肯变频器基本参数NXS系列伟肯变频器基本参数1:型号介绍- NXS系列伟肯变频器是一种高性能的数字变频驱动器,适用于各种工业自动化控制系统。
该系列变频器具有可编程的控制功能,能够实现精确的速度和位置控制,适用于各种负载条件和工作环境。
2:技术规格- 电源电压:AC220V- 频率范围:50Hz-60Hz- 功率范围:0:4kW-500kW- 控制方式:V/F控制、矢量控制- 输入信号:0-10V、0-20mA、4-20mA- 输出信号:0-10V、0-20mA、4-20mA、脉冲输出- 编码器接口:可配置AB相脉冲输入、ABZ相脉冲输入、SSI接口等3:控制参数- 加速时间:0-65535s可调- 减速时间:0-65535s可调- 频率设置范围:0-400Hz- 过载能力:150%额定电流,1分钟内4:保护功能- 过电流保护- 过电压保护- 地震出错保护- 瞬态过电压保护- 温度保护5:运行状态监测- 输出频率和电流显示- 输入电压和电流显示- 温度和故障显示- 运行时间显示6:外部接口- RS485通讯接口- MODBUS通讯协议- 可选配的扩展模块接口附件:- 产品手册- 安装指南- 编程手册法律名词及注释:- 变频器:也称为交流变频器或变频调速器,是一种能够通过改变电源频率来控制电机转速的电器设备。
- V/F控制:电压/频率控制,是一种用于控制交流电动机的速度的方法,通过调整电压和频率之间的关系,实现电机的调速控制。
- 矢量控制:也称为矢量变频控制,是一种通过控制电机的电流和磁场来实现精确调速的方法,适用于对速度和位置要求较高的应用。
NTB90N02T4中文资料
NTB90N02, NTP90N02 Power MOSFET90 Amps, 24 VoltsN−Channel D2PAK and TO−220Designed for low voltage, high speed switching applications in power supplies, converters and power motor controls and bridge circuits.Typical Applications•Power Supplies•Converters•Power Motor Controls•Bridge CircuitsMAXIMUM RATINGS (T= 25°C unless otherwise noted)1.When surface mounted to an FR4 board using 1″ pad size,(Cu Area 1.127 in2).2.When surface mounted to an FR4 board using minimum recommended padsize, (Cu Area 0.412 in2).*Chip current capability limited by package.N−ChannelDevice Package Shipping†ORDERING INFORMATIONNTP90N02TO−220AB50 Units/RailNTB90N02D2PAK50 Units/RailNTB90N02T4D2PAK800/T ape & Reel†For information on tape and reel specifications,including part orientation and tape sizes, pleaserefer to our T ape and Reel Packaging SpecificationsBrochure, BRD8011/D.ELECTRICAL CHARACTERISTICS(T J = 25°C unless otherwise noted)OFF CHARACTERISTICSON CHARACTERISTICS (Note 3)DYNAMIC CHARACTERISTICSSWITCHING CHARACTERISTICS (Note 4)SOURCE−DRAIN DIODE CHARACTERISTICS3.Pulse Test: Pulse Width ≤300 m s, Duty Cycle ≤ 2%.4.Switching characteristics are independent of operating junction temperatures.30I D , D R A I N C U R R E N T (A M P S )0R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (W )Figure 5. On−Resistance Variation withTemperature T J , JUNCTION TEMPERATURE (°C)Figure 6. Drain−To−Source LeakageCurrent versus VoltageV DS , DRAIN−TO−SOURCE VOLTAGE (V)50−50100750−2512515041612820102040R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (N O R M A L I Z E D )502560908010070C , C A P A C I T A N C E (p F )V G S , G A T E −T O −S O U R C E V O L T A G E (V )11000100110100Figure 9. Resistive Switching Time Variationversus Gate Resistance R G , GATE RESISTANCE (W )Figure 10. Diode Forward Voltage versusCurrentV SD , SOURCE−TO−DRAIN VOLTAGE (V)t , T I M E (n s ))10POWER MOSFET SWITCHINGSwitching behavior is most easily modeled and predicted by recognizing that the power MOSFET is charge controlled. The lengths of various switching intervals (D t)are determined by how fast the FET input capacitance can be charged by current from the generator.The published capacitance data is difficult to use for calculating rise and fall because drain−gate capacitance varies greatly with applied voltage. Accordingly, gate charge data is used. In most cases, a satisfactory estimate of average input current (I G(A V)) can be made from a rudimentary analysis of the drive circuit so thatt +Q ńI G(AV)During the rise and fall time interval when switching a resistive load, V GS remains virtually constant at a level known as the plateau voltage, V SGP . Therefore, rise and fall times may be approximated by the following:t r +Q 2 R 2ń10(V GG *V GSP )t f +Q 2 R 2ńV GSPwhere:V GG = the gate drive voltage, which varies fromzero to V GGR G = the gate drive resistance and Q 2 and V GSPare read from the gate charge curve.During the turn−on and turn−off delay times, gate current is not constant. The simplest calculation uses appropriate values from the capacitance curves in a standard equation for voltage change in an RC network.The equations are:t d(off)+R G C iss In (V GG ńV GSP )t d(on)+R G C iss In [V GG ń(V GG *V GSP )]The capacitance (C iss ) is read from the capacitance curve at a voltage corresponding to the off−state condition when calculating t d(on) and is read at a voltage corresponding to the on−state when calculating t d(off).At high switching speeds, parasitic circuit elements complicate the analysis. The inductance of the MOSFET source lead, inside the package and in the circuit wiring which is common to both the drain and gate current paths,produces a voltage at the source which reduces the gate drive current. The voltage is determined by Ldi/dt, but since di/dt is a function of drain current, the mathematical solution is complex. The MOSFET output capacitance also complicates the mathematics. And finally, MOSFETs have finite internal gate resistance which effectively adds to the resistance of the driving source, but the internal resistance is difficult to measure and, consequently, is not specified.The resistive switching time variation versus gate resistance (Figure 9) shows how typical switching performance is affected by the parasitic circuit elements. If the parasitics were not present, the slope of the curves would maintain a value of unity regardless of the switching speed.The circuit used to obtain the data is constructed to minimize common inductance in the drain and gate circuit loops and is believed readily achievable with board mounted components. Most power electronic loads are inductive; the data in the figure is taken with a resistive load, which approximates an optimally snubbed inductive load. Power MOSFETs may be safely operated into an inductive load;however, snubbing reduces switching losses.INFORMATION FOR USING THE D 2PAK SURFACE MOUNT PACKAGERECOMMENDED FOOTPRINT FOR SURFACE MOUNTED APPLICATIONSSurface mount board layout is a critical portion of the total design. The footprint for the semiconductor packages must be the correct size to ensure proper solder connection interface between the board and the package. With the correct pad geometry, the packages will self align when subjected to a solder reflow process.SOLDER STENCIL GUIDELINESPrior to placing surface mount components onto a printed circuit board, solder paste must be applied to the pads. Solder stencils are used to screen the optimum amount. These stencils are typically 0.008 inches thick and may be made of brass or stainless steel. For packages such as the SC−59, SC−70/SOT−323, SOD−123, SOT−23, SOT−143, SOT−223, SO−8, SO−14, SO−16, and SMB/SMC diode packages, the stencil opening should be the same as the pad size or a 1:1 registration. This is not the case with the DPAK and D2PAK packages. If one uses a 1:1 opening to screen solder onto the drain pad, misalignment and/or “tombstoning” may occur due to an excess of solder. For these two packages, the opening in the stencil for the paste should be approximately 50% of the tab area. The opening for the leads is still a 1:1 registration. Figure 11 shows a typical stencil for the DPAK and D2PAK packages. The pattern of the opening in the stencil for the drain pad is not critical as long as it allows approximately 50% of the pad to be covered with paste.Figure 11. Typical Stencil for DPAK andD2PAK PackagesSOLDER PASTEOPENINGSSTENCILSOLDERING PRECAUTIONSThe melting temperature of solder is higher than the rated temperature of the device. When the entire device is heated to a high temperature, failure to complete soldering within a short time could result in device failure. Therefore, the following items should always be observed in order to minimize the thermal stress to which the devices are subjected.•Always preheat the device.•The delta temperature between the preheat and soldering should be 100°C or less.*•When preheating and soldering, the temperature of the leads and the case must not exceed the maximum temperature ratings as shown on the data sheet. When using infrared heating with the reflow soldering method, the difference shall be a maximum of 10°C.•The soldering temperature and time shall not exceed 260°C for more than 10 seconds.•When shifting from preheating to soldering, the maximum temperature gradient shall be 5°C or less.•After soldering has been completed, the device should be allowed to cool naturally for at least three minutes.Gradual cooling should be used as the use of forced cooling will increase the temperature gradient and result in latent failure due to mechanical stress.•Mechanical stress or shock should not be applied during cooling.* *Soldering a device without preheating can cause excessive thermal shock and stress which can result in damage to the device.* *Due to shadowing and the inability to set the wave height to incorporate other surface mount components, the D2PAK is not recommended for wave soldering.TYPICAL SOLDER HEATING PROFILEFor any given circuit board, there will be a group of control settings that will give the desired heat pattern. The operator must set temperatures for several heating zones,and a figure for belt speed. Taken together, these control settings make up a heating “profile” for that particular circuit board. On machines controlled by a computer, the computer remembers these profiles from one operating session to the next. Figure 12 shows a typical heating profile for use when soldering a surface mount device to a printed circuit board. This profile will vary among soldering systems but it is a good starting point. Factors that can affect the profile include the type of soldering system in use, density and types of components on the board, type of solder used, and the type of board or substrate material being used. This profile shows temperature versus time.The line on the graph shows the actual temperature that might be experienced on the surface of a test board at or near a central solder joint. The two profiles are based on a high density and a low density board. The Vitronics SMD310 convection/infrared reflow soldering system was used to generate this profile. The type of solder used was 62/36/2 Tin Lead Silver with a melting point between 177−189°C. When this type of furnace is used for solder reflow work, the circuit boards and solder joints tend to heat first. The components on the board are then heated by conduction. The circuit board, because it has a large surface area, absorbs the thermal energy more efficiently, then distributes this energy to the components. Because of this effect, the main body of a component may be up to 30degrees cooler than the adjacent solder joint.STEP 1PREHEAT ZONE 1STEP 2VENT “SOAK”STEP 3HEATING ZONES 2 & 5STEP 4HEATING ZONES 3 & 6STEP 5HEATING ZONES 4 & 7STEP 6VENT STEP 7COOLING 200°150°100°5°°C Figure 12. Typical Solder Heating ProfilePACKAGE DIMENSIONSD2PAKCASE 418B−04ISSUE HNOTES:STYLE 2:PIN 1.GATE2.DRAIN3.SOURCE4.DRAINTO−220CASE 221A−09ISSUE AASTYLE 5:PIN 1.GATE2.DRAIN3.SOURCE4.DRAINON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.PUBLICATION ORDERING INFORMATION。
绿叶特克斯顿 IM 689 电缆弯曲机操作、服务和零件说明书
SAFETY ALERT SYMBOL
Immediate hazards which, if not avoided, WILL result in severe personal injury or death.
The symbol above is used to call your attention to instructions concerning your personal safety. Watch for this symbol. It points out important safety precautions. It means “ATTENTION! Become alert! Your personal safety is involved!” Read the message that follows and be alert to the possibility of personal injury or death.
OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL
880 HYDRAULIC BENDER
999 6196.2
Read and understand this material before operating or servicing this tool. Failure to understand how to safely operate this tool could result in an accident causing serious injury or death.
Greenlee Textron / Subsidiary of Textron Inc.
2
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Concens线性直行电机数据表说明书
Temperature Operation: - 20 ˚C to + 70 ˚C Storage: - 40 ˚C to + 70 ˚CCable specification Cores: 2 x AWG16 + 6 x AWG 28, Ø = 6,4 mm, black jacket, Molex Mini-Fit Jr. 8 pin or similar.Bending Radius6 x cable diameterActual weight may vary depending on model and options selectedFor other mechanical data please refer to Concens standard con 35/50/60 datasheet.GBD A T A S HE E TiconLinear In-line Actuator- excellent electric actuatorsStandard SpecificationsD A T A S HE E T | icon | December 2020 | 1i c o nCheck for updates at ConfigurationsContact Concens for availability at this timeIntelligent actuators with integrated controller (icon) enable the use of MODBUS RTU on an RS485 serial communication. One of the industry’s most powerful standards.The icon options provide everything from easy maintenance, control and installation, to a wide range of customizablesettings and feedback that will help tailor the movement solution to your specific needs and application.F eaturesAdjustable start ramp Adjustable stop ramp Adjustable current limitIndustrial interface MODBUS RTU on RS485 Internal stroke limitation Internal heat protectionDimensionsSame BID (Build in Dimension) as con35/50/60 with Hall. Please see original datasheet for con35/50/60Contact Concens for any special requirementsPlug & Play solution with conXion boxD A T A S HE E Ti c o nDisclaimerConcens A/S Øresundsvej 7DK-6715 Esbjerg N DenmarkT +45 70 11 11 31F +45 76 10 50 10E ****************VAT DK 10132266Max. Current load: icon35: 2 Adc @ 24 Vdc, 4 Adc @ 12 Vdc icon50: 8 Adc @ 24 Vdc, 16 Adc @ 12 Vdcicon60: 16 Adc @ 24 Vdc Idle current: Approx 10 mAdc Current trip delay: 20 ms PWM frequency: 25 kHzDigital inputs: ‘High’: Uin = 4 Vdc - Vsupply; ‘Low’: Uin = 0 Vdc - 1 VdcSupply voltage: 12 Vdc (min 10 Vdc at 1 meter cable, max 28 Vdc) or24 Vdc (min 20 Vdc at 1 meter cable, max 14 Vdc) (max ripple < 10 % @ full load)Serial data line: RS485 asynchronous, point to point or multi-point, 2 wire half-duplex Communications: Modbus RTU Bauds rate: 115000 bpsCom setup:8 Bit, Parity -None, Stop bit -1For more information on Modbus RTU please go to MODBUS over serial line specification and implementation guide V1.0Electrical Data10-0,00,2+Ø101613AluMax. static load 5400 N 2810-0,00,2+Ø10,21610Concens products are continuously developed, built and tested for highest requirements and reliability but it is always the responsibility of the customer to validate and test the suitability of our products in a given application and environment. We do our utmost to provide accurate and up-to-date information at all times. In spite of that, Concens cannot be held responsible for any errors in the documentation. Specifications are subject to change without prior notice.For more information, please visit our website at 。
MD7LWA LonWorks (ultra-slim, FTT-10A) 产品说明书
MODEL: MD7LWA Lightning Surge Protectors forElectronics Equipment M-RESTERLIGHTNING SURGE PROTECTOR FORLonWorksMODEL: MD7LWA–[1][2]Specify a code from below for each of [1] and [2].(e.g. MD7LWA-FF/Q)•Specify the specification for option code /Q(e.g. /C01)[1]SHIELD TERMINAL (to earth)FF: FloatingFG: Grounding[2]OPTIONSblank: none/Q: Options other than the above (specify the specification)/C01: Silicone coating/C02: Polyurethane coatingThis unit is not applicable to LonWorks Link Power network.Degree of protection: IP20Connection: Euro terminal block (torque 0.3 N·m)Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mmGrounding: DIN RailHousing material: Flame-resistant resin (black)Operating humidity: 30 to 90 %RH (non-condensing)Mounting: DIN Rail (TH35-7.5, 1-mm-thick)Oxide film on the surface of an aluminium DIN rail maylower the electric conductivity between this module and theground. Use a steel or copper rail.Weight: 70 g (2.5 oz)LINE TOLINELINE TOEARTHSHLD TOEARTHMax. continuousoperating voltage (Uc)±1.5V±100V±160V*1Voltage protection level(Up) @4kV (1.2 / 50 µs)±30V±370V±800V*1Leakage current @Uc≤ 5µA≤ 20µA≤ 5µA*1Response time≤ 4 nsec.≤ 20 nsec.≤ 20 nsec.*1Approx. capacitance@10 kHz100 pF100 pF 5 pF*1Max. discharge current(Imax)20kA (8 / 20 µs)1.0kA (10 / 350 µs)Nominal current (I N)100mAInternal series resistance≤ 3.3Ω including returnInsertion loss-0.5 dB max. @DC...5 MHz, Z0 = 100ΩSurge protection IEC 61643-21 Categories C1, C2, D1*1. V alues for the oating type (FF). Shortcircuited for the ground-ing type (FG).EMC DirectiveEMI EN 61000-6-4EMS EN 61000-6-2RoHS Directive056 222 38 18SEN TRONICAG8–M3 EURO*1. Be sure to use twisted-pair cables.*2. Choose the M-RESTER – FG when the shield wire is to be grounded.*3. When the twisted-pair cable is with a shield, connect it to the surge protector’s terminal 8, and follow instructions given by the protecteddevice for the terminal 7. When SHLD is not isolated from NET A / B, DO NOT connect the terminal 7 to SHLD.*4. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail.*5. Be sure to ground the DIN rail. Recommended grounding resistance max. 100 ohms.*6. Cross-wire from the DIN rail to the metal housing of the protected device to equalize the ground potential.Ground only the surge protector when the protected device has no grounding terminal.Protected Devices (Nodes)Protected Devices (Nodes)• T he M-RESTER is applicable to networks which consist only of FTT-10A. Not applicable to the ones connected to Link Power network.• The maximum number of nodes connectable to the network segment is reduced by one when one unit of M-RESTER is added.• When the distance between nodes are relatively long (e.g. grouped and separated by cabinets),install the M-RESTER by each group of devices. Insert the M-RESTER at the surge side of the network.• For detailed information on the network, refer to L ON W ORKS FTT-10A Free Topology Transceiver User’s Guide provided by Echelon.。
NKRQX24-MFT 产品数据手册说明书
NKRQX24-MFTMFT/programmable, Electrical fail-safe, 24 VTechnical dataElectrical data Nominal voltage AC/DC 24 VNominal voltage frequency50/60 HzNominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 VPower consumption in operation11 WPower consumption in rest position 3 WTransformer sizing22 VAElectrical Connection18 GA appliance or plenum cables, 1 m, 3 m or5 m, with or without 1/2" NPT conduitconnectorOverload Protection electronic throughout 0...95° rotationElectrical Protection actuators are double insulatedFunctional data Operating range Y 2...10 VOperating range Y note 4...20 mA w/ ZG-R01 (500 Ω, 1/4 W resistor)Input impedance100 kΩ for 2...10 V (0.1 mA), 500 Ω for 4 (20)mA, 1500 Ω for On/OffOperating range Y variable Start point 0.5...30 VEnd point 2.5...32 VOperating modes optional variable (VDC, on/off)Position feedback U 2...10 VPosition feedback U note Max. 0.5 mAPosition feedback U variable VDC variableSetting fail-safe position adjustable with dial or tool 0...100% in 10%incrementsBridging time (PF)0 sBridging time (PF) variable0...5 sPre-charging time9...18 sDirection of motion motor selectable with switch 0/1Direction of motion fail-safe reversible with switchManual override external push buttonAngle of rotation Max. 95°Angle of rotation note adjustable with mechanical stopRunning Time (Motor)4 s / 90°Running time motor variable 4...10 sRunning time fail-safe<4 sAdaptation Setting Range off (default)FootnotesFunctional dataOverride controlMIN (minimum position) = 0%MID (intermediate position) = 50%MAX (maximum position) = 100%Noise level, motor 60 dB(A)Noise level, fail-safe 60 dB(A)Position indicationMechanical, 30...65 mm stroke Safety dataPower source ULClass 2 Supply Degree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2Enclosure UL Enclosure Type 2Agency Listing cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2014/30/EU Quality Standard ISO 9001UL 2043 CompliantSuitable for use in air plenums per Section 300.22(C) of the NEC and Section 602 of the IMCAmbient humidity Max. 95% RH, non-condensing Ambient temperature -22...122°F [-30...50°C]Storage temperature -40...176°F [-40...80°C]Servicingmaintenance-free Weight Weight2.4 lb [1.1 kg]MaterialsHousing material Galvanized steel and plastic housing*Variable when configured with MFT options.Typical specificationBridging timeProduct featuresModulating control, electrical fail-safe damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to shaft up to 1.05" diameter. Actuators must provide modulating damper control response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller orpositioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. A 2 to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo.Power failures can be bridged up to a maximum of 5 s. In the event of a power failure, the actuator will remain stationary in accordance with the set bridging time. If the power failure is greater than the set bridging time, the actuator drives to the selected fail-safe position.The bridging time set at the factory is 0 s. This can be modified on site in operation by means of the Belimo service tool MFT-P.Settings: The rotary knob must not be set to the "PROG FAIL-SAFE" position!For retroactive adjustments of the bridging time with the Belimo service tool MFT-P or with the ZTH EU adjustment and diagnostic device only the values need to be entered.AccessoriesGatewaysDescriptionType Gateway MP to BACnet MS/TP UK24BAC Gateway MP to Modbus RTUUK24MODDescriptionType Gateway MP to LonWorksUK24LON Electrical accessoriesDescriptionType Auxiliary switch, mercury-free P475Auxiliary switch, mercury-freeP475-1Signal simulator, Power supply AC 120 V PS-100Feedback potentiometer 140 Ω add-on, grey P140A GR Feedback potentiometer 500 Ω add-on, grey P500A GR Feedback potentiometer 1 kΩ add-on, grey P1000A GR Feedback potentiometer 2.8 kΩ add-on, grey P2800A GR Feedback potentiometer 5 kΩ add-on, grey P5000A GR Feedback potentiometer 10 kΩ add-on, grey P10000A GR Auxiliary switch 1x SPDT add-on S1A Auxiliary switch 2x SPDT add-onS2A Service tool, with ZIP-USB function, for programmable andcommunicative Belimo actuators, VAV controller and HVAC performance devicesZTH USToolsDescriptionTypeConnecting cable 10 ft [3 m], A: RJ11 6/4 ZTH EU, B: 3-pin Weidmüller and supply connectionZK4-GEN Service tool, with ZIP-USB function, for programmable and communicative Belimo actuators, VAV controller and HVAC performance devicesZTH USElectrical installationWarning! Live electrical components!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical componentscould result in death or serious injury.Meets cULus requirements without the need of an electrical ground connection.Actuators with appliance cables are numbered.Provide overload protection and disconnect as required.Actuators may also be powered by DC 24 V.Only connect common to negative (-) leg of control circuits.A 500 Ω resistor (ZG-R01) converts the 4...20 mA control signal to 2...10 V.Actuators may be connected in parallel if not mechanically linked. Power consumption andinput impedance must be observed.IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 40155).Wiring diagrams On/OffVDC/mA ControlNKRQX24-MFTElectrical installationWiring diagramsOverride ControlDimensions。
Kinetix系列低紧急性电动机数据手册说明书
SPECIFICATIONSProduct SeriesComponent Type Motion Control Mounting, MotorBrakeFood GradeConnector, Motor EndKeyed ShaftFeedback TypeFeedback Resolution Feedback ProtocolSpeed, RatedSpeed, MaxMagnet Stack LengthFrame SizeVoltage ClassShaft SealSpecial / CustomOutput Torque, Continuous Output Torque, Peak Compatible Drive Series'Rated Power, ContinuousRotor InertiaOperating Temperature, Max Operating Temperature, Min MPL Low InertiaRotary Servo MotorFlange Mount, MetricNo Y / NNoSpeedTec DIN (Type M7)Yes Y / NAbsolute Single-turn typeSin/Cos, 128 cycles/rev resolutionHiperface protocol7000rpm7000rpm20 = 50.8mmFrame 15 / Frame 063 = 63mm size200V ACNo Y / NNo0.49Nm, continuous1.58NmKinetix 5500 (Bul. 2198)Kinetix 6200 / 6500 (Bul. 2094)Kinetix 6000 (Bul. 2094)Kinetix 300 (Bul. 2097)Kinetix 350 (Bul. 2097)Kinetix 2000 (Bul. 2093)Kinetix 7000 (Bul. 2099)Ultra 3000 (Bul. 2098)compatible0.27kW continuous1.3E-05kg m², rotor40°C max0°C min·Continuous stall torque of 0.26 to 163Nm (2.3 to 1440lb-in.)·Peak torque of 0.77 to 278Nm (6.8 to 2460lb-in.)·Integral 24V brake option·Absolute multi-turn and single-turn high resolution, incremental encoder and resolver feedback options·Low-profile, field-reversible motor connectors for minimal servo motor impact on machine design·DIN connector versions allow flexible orientation of connectors and use of a single cable family with all MP-Series motorsRepresentative Photo Only(actual product may vary based on configuration selections)MP SERIES MPL 240V SERVO MOTOR,0.49 N-M,7000 RPM1300 NHP NHP | .au | 0800 NHP NHP | MPLA1520UEJ72AA DatasheetNHP Electrical Engineering ProductsOperating Temperature, MinStorage Temperature, MaxStorage Temperature, MinRelative humidity, minRelative Humidity, MaxHumidity typeWeightIP RatingDetails, IP RatingShock Acceleration (Max.)Shock Duration (Max.)Vibration Acceleration (Max.)Vibration Frequency, Operational (Max.)0°C min70°C max-30°C min5%RH95%RHNon-condensing1.2kgIP50IP66IP50 minimum, without shaft seal; IP66 with optional shaft seal and use of environmentally sealed cable connectors20g6ms2.5g2000HzREFERENCESInstallation Guide:-User Manual:-Manufacturer Datasheet:-Manufacturer Catalogue & Product Selection:-Supplier Declaration of Conformity:-IECEx Certificate-1300 NHP NHP | .au | 0800 NHP NHP | MPLA1520UEJ72AA DatasheetNHP Electrical Engineering Products。
24VAC±20% 50 60Hz 9.5VA电源驱动型电机说明书
† Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3.AVKX24-3On/Off, Floating Point, Electronic Fail-Safe, Linear, 24 VD a t e c r e a t e d , 11/03/2016 - S u b j e c t t o c h a n g e . © B e l i m o A i r c o n t r o l s (U S A ), I n c .Meets cULus requirements without the need of an electrical groundconnection.Provide overload protection and disconnect as required.Actuators may be connected in parallel. Power consumption and inputimpedance must be observed.Control signal may be pulsed from either the Hot (Source) or Common(Sink) 24 VAC line.Actuators may be connected in parallel if not mechanically linked. Powerconsumption and input impedance must be observed.Actuators with plenum cable do not have numbers; use color codes instead.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.AVKX24-3On/Off, Floating Point, Electronic Fail-Safe, Linear, 24 VD a t e c r e a t e d , 11/03/2016 - S u b j e c t t o c h a n g e . © B e l i m o A i r c o n t r o l s (U S A ), I n c .。
Furman PST-6 电源保护设备说明书
The PST-6IntroductionThank you for purchasing the Furman Power Station-6 Power Conditioner. For over 30 years, Furman has pioneered the development of AC power products for the most demanding audio, video, and broadcast professionals. Furman’s Ground Contamination Free Surge Protection, Advanced Filtering Technology, and Digital-HD Television Ready circuitry can signifi cantly improve your sensitive components while protecting them from spikes, surges and contaminated AC power.Today’s power grid typically experiences numerous electrical surges and spikes on a daily basis. At best, these irregularities can degrade your equipment’s performance; at worst, they can severely damage individual components or your entire system. Not so with Furman.With our exclusive Ground Contamination Free Surge Protection, your valued equipment is protected without the long-term damaging effect of conventional surge strips.Safety InformationTo obtain best results from your Furman Power Station-6 Power Conditioner, please be sure to read this manual carefully before using.Warning:To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. Dangerous high voltages are present inside the enclosure. Do not remove the covers. There are no user serviceable parts inside. Refer servicing to qualifi ed personnel only.2Important Safety Instructions:1. Please read and observe all safety and operating instructions before installing your Power Station-6 (PST-6). Retain these instructions for future reference.2. Your PST-6 should not be used near water – for example, neara bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming pool, etc.3. Do not place your PST-6 near heat sources such as radiators, heat registers, stoves or other appliances that produce heat.4. The PST-6 should only be connected to a 120 VAC, 60Hz, 15 amp grounded electrical outlet. Do not defeat the ground or change polarization of the power plug.5. Route the power cord and other cables so that they are not likely to be walked on, tripped over, or stressed. Pay particular attention to the condition of the cords and cables at the plugs, and the point where they exit your PST-6. To prevent risk of fi re or injury, damaged cords and cables should be replaced immediately.6. Clean your PST-6 with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour liquid on or into the unit.7. Your PST-6 should be serviced by qualifi ed service personnel when:3• The power supply cord or the plug has been frayed, kinked, or cut.• Objects have fallen or liquid has spilled into the unit.• The unit has been exposed to rain or other moisture.• The unit does not appear to operate normally, exhibits a marked change in performance, or the Protection OK indicator is not lit.• The unit has been dropped, or the enclosure damaged.8. Your PST-6 requires that a safety ground be present for properoperation. Any attempt to operate the unit without a safety ground is considered improper operation and could invalidate the warranty.OperationAC, Telephone, and Coaxial ConnectorsTelco – Satellite / Cable Transient Voltage Surge Suppressors: The PST-6 features transient voltage surge suppression for both standard telephone lines, as well as cable and satellite lines utilizing standard coaxial connectors. As these surge suppressors are in-line, they will require an additional cable (supplied with the PST-6) to connect from their output to the control device requiring protection.All in-line surge suppressors feature our exclusive ground contamination free technology. This aids in eliminating audio buzzing, and the video hum-bars that can result from typical in-line suppressors. Further, our cable and satellite suppressors are TIVO friendly as well as HD-Digital Television ready. Both DC carrier signals as well as high bandwidth signals can pass through our 4circuit. In fact the bandwidth is less than 0.1dB loss at 1GHz!To connect your cabling to these in-line protectors, simply follow thein and out indications marked next to the Telco, and Cable / Satellite connectors.Note:It is not possible to make an in-line cable / satellite protector “maintenance-free.” Under extreme conditions, it is possible that the surge suppression in one of these devices could sacrifi ce itself after a catastrophic event. If the telephone, cable or satellite signal will no longer pass through our protector, please send your Power Station to Furman for servicing. To test this, simply disconnect the incoming and out going cable from the PST-6. Connect the incoming connector to the component that formerly received the out going connector, thus by-passing the in-line protection. If the signalis present (but not when used with the PST-6) then the protection circuit is damaged (assuming it worked properly before the storm or catastrophic event).Circuit BreakerIf the PST-6 is connected to an AC outlet where suffi cient voltageis present, the unit should operate properly with the protection OK indicator lit, after the main power switch is turned to the on position.If the unit still does not function under these conditions check the circuit breaker button! It is the round black button adjacent to the incoming AC cord. If the circuit breaker trips immediately, there may be too great of a current load placed upon it. Simply disconnect one5product at a time until this no longer happens. If the breaker trips with no components connected, there may be a wiring defect that requires Furman service.IndicatorsProtection OK Indicator:Although Furman’s Ground Contamination Free Surge Suppression rarely requires servicing, nature has a way of occasionally creating electrical forces that are beyond the capabilities of any transient voltage surge suppressor device to absorb without some degree of damage. In the instance that this occurs, the blue “Protection OK” LED indicator will turn off. If this happens, Furman’s surge suppression circuit is compromised. The unit must be returned to Furman Sound, or an authorized Furman Service Center for repair.MountingIf the Power Station needs to be mounted to the inside panel of a rack or hung from a wall, a convenient crossed oval cutout is provided on the unit’s bottom panel. A standard No. 6 pan head screw can be used in the same way a picture is hung from a wall. Simply measure the centers on the bottom of your Power Station. This will be the distance from the two mounting holes drilled into your wall, rack or cabinet surface. Once the screw is fastened fl ush with the surface, back it out approximately ½”. The screw head should push through the crossed cutout on the bottom surface of the Power Station. Next, simply allow the Power Station to move down and seat into the end of its oval cut-out. Adjust the pan head screw if necessary.6WarrantyFurman Sound, Inc., having its principal place of business at 1997 South McDowell Blvd., Petaluma, CA 94954 (“Manufacturer”) warrants its PST-6 (the “Product”) as follows:Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of one year from the date of purchase. The Purchaser of the product is allowed fi fteen days from the date of purchase to complete warranty registration by mail or on-line at the Furman website. If the Product does not conform to this Limited Warranty during the warranty period (as herein above specifi ed), Purchaser shall notify Manufacturer in writing of the claimed defects. If the defects are of such type and nature as to be covered by this warranty, Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location. Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date; this is not necessary if the Warranty Registration was completed either via the mailed in warranty card or on-line website registration. Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the Purchaser of the product. Manufacturer shall, at its own expense, furnish a replacement Product or,at Manufacturer’s option, repair the defective Product. Return shipping charges back to Purchaser will be paid by Manufacturer.THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS7FOR A PARTICULAR PURPOSE. Manufacturer does not warrant against damages or defects arising out of improper or abnormal use of handling of the Product; against defects or damages arising from improper installation, against defects in products or components not manufactured by Manufacturer, or against damages resulting from such non-Manufacturer made products or components. This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modifi ed in any way without written authorization from Furman Sound.This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer.THIS WARRANTY IS EXCLUSIVE. The sole and exclusive obligation of Manufacturer shall be to repair or replace the defective Product in the manner and for the period provided above. Manufacturer shall not have any other obligation with respect to the Products or any part thereof, whether based on contract, tort, strict liability or otherwise.Under no circumstances, whether based on this Limited Warranty or otherwise, shall Manufacturer be liable for incidental, special, or consequential damages. Manufacturer’s employees or representatives’ ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES, shall not be relied upon by Purchaser, and are not a part of the contract for sale or this limited warranty. This Limited Warranty states the entire obligation of Manufacturer with respect to the Product.If any part of this Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect.8ServiceAll equipment being returned for repair must have a Return Authorization (R/A) Number. To get an R/A number, please call the Furman Service Department at (707) 763-1010 ext 121, between the hours of 8:00 am and 5:00 pm US Pacifi c Time. When returning equipment for repair, please use the original packaging to ship the product. Also, please enclose a note giving your name, address, phone number, e-mail address, and a description of the problem. Please display your R/A Number prominently on the front of all packages.91011Furman Sound, Inc.1997 South McDowell Blvd.Petaluma, California 94954-6919 USAPhone: 707-763-1010Fax: 707-763-1310Web: E-mail:********************12011104-D。
日本NTS称重传感器
日本NTS称重传感器日本NTS称重传感器接线称重传感器的接线方式最常用到的就是4线制和6线制接线,要接4线还是6线首先要看你的硬件要求是怎样的,例如:tedea 619是六线制接线,而celtron loc和tedea 1010却是四线制接线。
但是一定要记住的一点是:能接6线的绝对不接4线传感器,必须接4线的就一定要进行短接。
日本NTS称重传感器尺寸型式定格容量φAB CφDE FφGH φI J K質量(kg)LCZ-5KN 5kN 88 85 50 5M6深サ102570118281.53LCZ-10K N 10kN 88 85 505M6深サ102570118281.53LCZ-20K N 20kN 88 85 505M6深サ102570118281.53LCZ-50K N 50kN10811107M8深サ1525901535431.56LCZ-100K N 100kN10811107M8深サ1525901535431.56LCZ-200K N 200kN13816208M12深サ20251125072 11LCZ-500K N 500kN13816208M12深サ20251125072 12LCZ-1000 KN 1000kN16419251M16深サ20281337082 17日本NTS称重传感器量程LCZ-5KN、LCZ-10KN、LCZ-20KN、LCZ-50KN、LCZ-100KN、LCZ-200KN、LCZ-500KN、LCZ-1000KN、LRK-100N、LRK-200K、LRK-500N、LRK-1KN、LRK-2KN、LRM-20N、LRM-50N、LRM-100N、LRM-200N、LRM-500N、LRM-1KN、LRM-2KN、LRM-5KN、LRM-10KN、LRM-20KN、PCD-1MP、PCD-2MP、PCD-5MP、PCD-10MP、PCD-20MP、PCD-50MP、PCD-L-500KP、日本NTS称重传感器参数量程:……………………………………… 100N~~~20KN灵敏度:……………………………………… ±2mV/V±1%非直线性:…………………………………………0.05%R.O.滞后:……………………………………………….. 0.05%R.O.重复性:…………………………………………… 0.03%R.O.推荐电压:…………………………………… 10V(100N~200N是5V)允许最大电压:……………………………………18V(100N~200N是10V)输出阻抗: (350)绝缘阻抗:……………………………………… 2000MΩ以上温度补偿范围:………………………………… -10~+70℃(100N~200N是-10~+60℃使用温度范围:…………………………………… -20~+80℃(100N~200N是-10~+60℃零点温漂:………………………………………… ±0.01%R.O./℃满程温漂:……………………………………….. ±0.01%/℃允许过载:…………………………………… 120%R.C.标准电缆:…………………………………………φ6,4芯屏蔽电缆3米(500N~20kN)φ3,4芯屏蔽电缆3米(100N~200N)S型结构,可拉伸或压缩使用,对材料试验机或汽车零部件的检测适用很广。
澳大利亚Eaton PDG24N0060B2NJ电源防御电路保护器说明说明书
Eaton PDG24N0060B2NJEaton Power Defense molded case circuit breaker, Globally Rated, Frame 2, Four-pole (100% N), 60A, 85kA/480V, PXR10 LSI TU, Standard Line and Load (PDG2X4T100)General specificationsEaton Power Defense molded case circuit breakerPDG24N0060B2NJ 78667936344788.9 mm 152.4 mm 139.5 mm 2.46 kg Eaton Selling Policy 25-000, one (1) year from the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.RoHS Compliant IEC 60947-2CCC MarkedProduct NameCatalog Number UPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCompliancesCertifications60 AComplete breaker 2Four-pole (100% N)PD2 Global Class A PXR 10 LSI600 Vac 600 V100% neutral protection Standard Line and Load85 kAIC at 480 Vac30/25 kAIC @600V (UL/CSA)85 kAIC @480V (UL)30/25 kAIC Icu/ 15/13 kAIC Ics @525V South Africa (IEC) 150 kAIC Icu/ 100 kAIC Ics/ 330 kAIC Icm @240V (IEC)22 kAIC Icu @250 Vdc10 kAIC Icu/ 5 kAIC Ics/ 21 kAIC Icm @690V (IEC)70 kAIC Icu/ 50 kAIC Ics/ 154 kAIC Icm @440V (IEC)22 kAIC Icu @125 Vdc150 kAIC @240V (UL)65 kAIC Icu/ 40 kAIC Ics/ 143 kAIC Icm @480V Brazil (IEC) 70 kAIC Icu/ 70 kAIC Ics/ 154 kAIC Icm @380-415V (IEC) 25 kAIC @600V (UL/CSA)Eaton Power Defense MCCB PDG24N0060B2NJ 3D drawingConsulting application guide - molded case circuit breakersPower Xpert Protection Manager x32Power Xpert Protection Manager x64Power Defense brochurePower Defense molded case circuit breaker selection posterPower Defense technical selling bookletPower Defense molded case circuit breakers - Frame 2 product aidMolded case circuit breakers catalogPower Xpert Release trip units for Power Defense molded case circuit breakersAmperage RatingCircuit breaker frame type FrameNumber of poles Circuit breaker type ClassTrip TypeVoltage rating Voltage rating - maxProtection TerminalsInterrupt rating Interrupt rating range 3D CAD drawing package Application notesBrochuresCatalogsCertification reportsEU Declaration of Conformity - Power Defense molded case circuit breakersPDG4 CB reportPDG4 CCC certificationPDG2 CB reportInstallation instructionsPower Defense Frame 2 terminal kit - PDG2X3(2)(4)TA225RF instructions - IL012245EN H01Power Defense Frame 2/3/4/5/6 voltage neutral sensor module wiring instructions – IL012316ENPower Defense Frame 2 locking devices and handle block instructions - IL012149ENPower Defense Frame 2 tunnel terminal (aluminum), 150A, 4 pole instructions - IL012238EN H04Power Defense Frame 2 tunnel terminal (aluminum), 100A, 4 pole instructions - IL012237EN H04Power Defense Frame 1-2-3-4 IP door barrier assembly instructions -IL012278ENPower Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2253W instructions - IL012243EN H01Power Defense Frame 2 tunnel terminal kits - PDG2X1TA225K instructions- IL012239EN H01Power Defense Frame 2 box terminal (steel), 100A, 4 pole instructions - IL012234EN H04Power Defense Frame 2 screw terminal_end cap kit, 225A, 3 pole instructions - IL012258EN H01Power Defense Frame 2 clamp terminal (steel), 20A, 4 pole instructions - IL012246EN H04Power Defense Frame 2 box terminal (aluminum), 225A, 4 pole instructions - IL012235EN H04Power Defense Frame 2 PDG2 and PDC(E)9 breaker instructions -IL012106ENPower Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2256W instructions - IL012242EN H01Power Defense Frame 2 Bell Alarm Switch Instructions (IL012154EN).pdf Power Defense Frame 1 IEC and Frame 2 Rotary Mechanism with NFPA Handle Attachment Instructions (IL012260EN).pdfPower Defense Frame 2 shunt trip UVR instructions - IL012130EN Power Defense Frame 2 terminal kit - PDG2X3(2)(4)TA150RF instructions - IL012244EN H01Power Defense Frame 2 global terminal shield, 4 pole - IL012330ENPower Defense Frame 2 tunnel terminal (aluminum), 50A, 4 pole instructions - IL012236EN H04Installation videosPower Defense Frame 2 Bell Alarm with PXR Animated Instructions.pdf.rh Power Defense Frame 2 withTMTU, Shunt Trip_UVR Animated Instructions.rhPower Defense Frame 2 TMTU Aux, Alarm, ST and UVR Animated Instructions.rhMultimediaPower Defense Frame 2 Direct Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 3 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 2 Aux, Alarm, Shunt Trip, and UVR How-To Video Power Defense Frame 2 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense molded case circuit breakersEaton Power Defense for superior arc flash safetyPower Defense Frame 6 Trip Unit How-To VideoPower Defense BreakersPower Defense Frame 5 Trip Unit How-To VideoSpecifications and datasheetsEaton Specification Sheet - PDG24N0060B2NJTime/current curvesPower Defense time current curve Frame 2 - PD2White papersIntelligent power starts with accurate, actionable dataMaking a better machineIntelligent circuit protection yields space savingsMolded case and low-voltage power circuit breaker healthSingle and double break MCCB performance revisitedMolded case and low-voltage breaker healthSafer by design: arc energy reduction techniquesEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
腾纳TNPS2000 综合继电保护装置 产品说明书
TNPS2000综合继电保护装置产品说明书广东腾纳智能科技有限公司电话:*************服务热线:400-6821-018传真:*************网址:邮箱:E-mail:****************公司地址:广东省东莞市南城街道白马黄金一路5号2栋邮编:523000一、产品概述保护:三段式(速断、限时速断、定时限过流)电流保护(可选择方向);三相一次重合闸(可选择检同期、检无压、非同期);后加速;反时限过流保护(IEC三种标准曲线可选择);过负荷保护;低周减载(可带低电流闭锁、低电压闭锁、滑差闭锁);过电压保护;低电压保护;零序过流(两段)保护;零序过压保护;单相接地;PT断线;控制回路断线告警。
保护出口:保护分、合闸独立出口。
信号出口:控制回路断线、预告、事故、装置故障信号独立出口。
遥控:遥控分、合闸独立出口。
遥调:各保护功能均可实现远方投入/退出;系统参数、保护定值可实现远方修改;信号可实现远方复归。
遥信:保护动作信息、PT断线告警、控制回路断线告警;10路独立开关量输入;开关量事件记录等可实现远方监视。
遥测:电流测量、电压测量、频率测量、相序测量、功率测量、功率因数测量、正向有功电度、正向无功电度、反向有功电度、反向无功电度,均可实现远方实时监视。
接线识别:可实时监视电压回路、保护电流回路及测量电流回路的相序和相位。
数据统计:断路器跳、合闸统计,包括总的跳闸次数、保护动作跳闸次数、手动跳闸次数、遥控跳闸次数;总的合闸次数、手动合闸次数、遥控合闸次数。
通信:两线标准RS485通信接口;标准的ModBUS RTU通讯协议。
二、技术参数:(1)机械及工作环境条件机箱结构尺寸:120(高)×207(宽)×130(深)mm表面嵌入式安装,开孔尺寸:114(高)×202(宽)mm储存、运输及安装允许的环境温度:-25~+70℃工作环境温度:-10~+55℃相对湿度:5%~95%大气压力:80~110Kpa(2)电源输入额定电压:DC/AC220V/110V;DC48V(定货注明)输入允许偏差:80%~115%输入允许中断时间:<0.5S输出纹波及噪声:1%或100mV(3)额定参数交流电流:5A或1A(定货注明)交流电压:100V或100/3V频率:50Hz/60Hz(定货注明)动作出口和信号出口输出触点负载:6A250VAC/30VDC(4)功率消耗交流电流回路:当额定电流时,每相不大于0.5VA交流电压回路:当额定电压时,每相不大于0.1VA工作电源回路:当正常工作时,不大于4.5W;当保护动作时,不大于5.0W (5)过载能力交流电流回路2倍额定电流,连续工作10倍额定电流,允许工作10s40倍冲击电流,允许工作1s交流电压回路:1.2倍额定电压,连续工作1.4倍额定电压,允许工作10s(6)精度保护电流、电压元件:满量程误差≤±1.0%测量电流、电压元件:满量程误差≤±0.5%测量功率元件:误差≤±1.0%频率偏差:≤±0.5%瞬动时间:≤50ms反时限时间:≤±5%事件分辨率:≤2ms(7)保护整定电流整定:范围:0.1~20In步长:0.01A时间整定:范围:0~99.99S步长:0.01S电压整定:范围:0.1~120V步长:0.01V频率整定:范围:45~55Hz步长:0.01Hz滑差整定:范围:0.1~10Hz/S步长:0.01Hz/S(8)重合闸整定重合闸一次脉冲充电时间:15S重合闸向量差:0~30V步长:0.01V重合闸时间:整定范围为0.1~10s步长:0.01s(9)绝缘性能、介质强度、冲击电压、机械性能(振动、冲击、碰撞)均符合DL478-2001的要求。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Features
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliance applications.
PC board mounting and direct insert mounting available.
Ordering Information
NT90T H L A S DC12V C B 0.9
1 2 3 4 5 6 7 8 91 Part number :NT90T 、NT90T 22 Load :H:30A ;N:40A
3 High :NIL: Standard ;L: Low profile type
4 Contact arrangement :A:1A ;B:1B ;C:1C
5 Enclosure :S: Sealed type ;D: Dust cover ; E: Covered ;O: Open type
6 Coil rated Voltage(V):AC:12,24,110,120,220
DC:3,5,6,9,12,15,18,24,48,1107 Contact material :C: Ag CdO ;S: Ag SnO 28 Resist heat class :B:130℃ F:155℃
9 Coil power consumption :0.6:0.6W ;0.9:0.9W NIL:2VA
Contact Data
Contact Arrangement 1A SPSTBNO f 1B SPSTNC f 1C SPDT(B-M) Contact Material
Ag CdO Ag SnO 2 Ag SnO 2 In 2O 3
Contact Rating (resistive)
NO :30A/240VAC,14VDC ;NC :20A/240VAC ;30A/14VDC NO :40A/250VAC,30VDC ;NC :30A/250VAC,30VDC (0.9W)Motor load :2HP 250VAC ;1.5HP 250V Lamp load :TV-5Max. Switching Power
1100W 7200VA
Max. Switching Voltage
110VDC 250VAC Max. Switching Current:40A Contact Resistance or Voltage drop አ30m Item 3.12 of IEC255-7Electrical 105
Item 3.30 of IEC255-7Operation life Mechanical
107
Item 3.31 of IEC255-7
Coil Parameter
AC Coil Parameter
RATED VOLTAGE
VAC
DASH NUMBERS
RATED
Max
COIL RESISTANCE ±10%
PICK UP VOLTAGE VAC(max)(75%of rated voltage)RELEASE VOLTAGE VAC(min)(30%of rated voltage)
COIL POWER
Operate Time ms Release Time ms
012AC 1215.6279.0 3.6024AC 24
31.212018.07.2110AC 110143236082.533.0120AC 120156304090.036.0220AC
220
28613490165.066.0
2VA __
CAUTION : 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
元器件交易网
003-9003 3.9。