三菱e500变频说明书
****
三、Description of function setting Parameter setting:
Note :
1.These parameter setting will be ignored and void if selected under universal
magnetic beam vector control mode.
2.Calibration executed while ex-factory, the setting value of each inverter will be
differing more or less to each other. The setting value will be slightly higher than 60Hz frequency setting.
3.If the setting value exceeds 100Hz while using the operating device, the setting
unit will be changed to 0.1Hz.
4.The setting value is differ depend of the different capacity of the inverter.
5.Inverter 0.1~0.75K will be set to 85% of rated current.
6.While running, even if the Pr.77『parameter lock selection』=『2』is unable to
change the set value.
7.The parameter even if the Pr.77『parameter lock selection』=『0』
(ex-factory default), while the inverter is running, set value of these parameters may be changed.(but the setting value of Pr.72,Pr.240 in external run can’t be changed)
8.The setting range of Pr.80 will be differ depend of different inverter, the setting
range for class 400W is 0.2KW~7.5W, 999.
9.Pr.249 is only available in class 200W inverter
10.The ex-factory setting of Pr.0 will be differ depend on the different capacity of the
inverter, such as FR-E540-5.5K, 7.5K is 4%.。