16g101平法图集-钢筋的连接方式搭接长度及相关规定(第二节)
16G101三维图集学习教程(全本)

16建筑三维平法结构识图教程目录第一章:钢筋锚固长度及其相关规范1.1受拉钢筋基本锚固长度L ab ,L abE受拉钢筋锚固长度修正系数·····························1.2混凝土结构的环境类别混凝土保护层的最小厚度(mm )纵向受力钢筋搭接区箍筋构造 ·····························1.3纵向钢筋弯钩与机械锚固形式纵向受拉钢筋綁扎搭接长度L L 、L LE ··························1.4封闭箍筋及拉筋弯钩构造梁并筋等效直径、最小净距梁柱纵筋间距要求螺旋箍筋构造 ·································1.5封闭箍筋及拉筋弯钩构造基础梁箍筋复合方式非接触纵向钢筋搭接构造·····························································第二章:柱平法标准构造详图及三维示意图2.1·······························2.2抗震KZ 纵向钢筋连接构造······························2.3地下室抗震KZ 的纵向钢筋连接构造、地下室抗震KZ 的箍筋加密区范围 ··························2.4抗震框架柱和角柱柱顶纵向钢筋构造·························2.5抗震KZ 中柱顶纵向钢筋构造······························2.6抗震KZ 柱变截面位置纵向钢筋构造···························2.7抗震KZ 、QZ 、LZ 箍筋加密区范围抗震QZ 、LZ 纵向钢筋构造 ······························2.8抗震框架柱和小墙肢箍筋加密区高度选用表·······················2.9非抗震KZ 纵向钢筋连接构造·····························2.10非抗震KZ 边柱和角柱柱顶纵向钢筋构造························2.11非抗震KZ 中柱顶纵向钢筋构造····························2.12非抗震KZ 柱变截面位置纵向钢筋构造·························2.13非抗震KZ 箍筋构造非抗震QZ 、LZ 纵向钢筋构造······························第三章:剪力墙平法标准构造详图及三维示意图3.1剪力墙身水平钢筋构造................................27.. (31)3.3剪力墙身竖向钢筋构造 (32)3.4约束边缘构件YBZ 构造 (35)3.5剪力墙水平钢筋计入约束边缘构件体积配箍率构造做法 (37)3.6构造边缘构件GBZ 、扶壁柱FBZ 、非边缘暗柱AZ 构造剪力墙边缘构件纵向钢筋连接构造剪力墙约束边缘构件纵筋构造 (38)3.8剪力墙 LL /AL BKL 配筋构造 (39)3.9剪力墙BKL 或AL 与LL 重叠时配筋构造··························403.10连梁交叉斜筋配筋LL (JX )连梁集中对角斜筋配筋LL (DX )连梁对角暗撑配筋LL (JC )构造 (42)3.11地下室外墙DWQ 钢筋构造...............................433.12剪力墙洞口补强构造 .. (45)第四章:梁平法标准构造详图及三维示意图 (47)4.2抗震屋面框架梁WKL 纵向钢筋构造 (48)4.3非抗震楼层框架梁KL 纵向钢筋构造 (49)4.4非抗震屋面框架梁WKL 纵向钢筋构造 .........................504.5框架梁水平、竖向加腋构造.. (51)ζa 1.6芯柱XZ 配筋构造矩形箍筋复合方式柱插筋在基础中的锚固3.2墙插筋在基础中的锚固4.1抗震楼层框架梁WKL 纵向钢筋构造4.6KL 、WKL中间支座纵向钢筋构造 (53)4.7抗震框架梁KL、WKL箍筋加密区构造抗震框架梁KL、WKL箍筋加密区构造 (54)4.8梁与方柱斜交或与圆柱相交时箍筋起始位置 (55)4.9非框架梁L配筋构造主次梁斜交箍筋构造 (56)4.10不伸入支座的梁下部纵向钢筋断点位置附加箍筋范围、附加吊筋构造梁侧面纵向构造筋和拉筋 (57)4.11非框架梁L中间支座纵向钢筋构造水平折梁、竖向折梁钢筋构造 (58)4.12纯悬挑梁XL及各类梁的悬挑端配筋构造 (59)4.13KZZ/KZL配筋构造 (51)4.14井字梁JZL配筋构造 (65)第五章:板平法标准构造详图及三维示意图5.1有梁楼盖楼(屋)面板配筋构造 (67)5.2有梁楼盖不等跨板上部贯通纵筋连接构造 (69)5.3单(双)向板配筋示意纵向钢筋非接触搭接构造 (70)5.4悬挑板XB钢筋构造 (71)5.5无支撑板端部封边构造折板配筋构造 (72)5.6无梁楼盖柱上板带ZSB与跨中板带KZB纵向钢筋构造 (73)5.7板带端支座纵向钢筋构造板带悬挑端纵向钢筋构造 (74)5.8柱上板带暗梁钢筋构造 (75)5.9板后浇带HJD钢筋构造墙后浇带HJD钢筋构造梁后浇带HJD钢筋构造 (76)5.10板加腋JY构造局部升降板SJB构造(一) (77)5.11板加腋JY构造局部升降板SJB构造(二) (78)5.12板开洞BD与洞边加强钢筋构造一(洞边无集中荷载) (79)5.13板开洞BD与洞边加强钢筋构造二(洞边无集中荷载) (80)5.14悬挑板阳角放射筋Ces构造 (81)5.15板内纵筋加强带JQD构造板翻边FB构造悬挑板阴角构造 (82)5.16柱帽ZMa、ZMb,ZMc、ZMab构造 (83)5.17抗冲切箍筋Rh构造抗冲切弯起筋Rb构造 (84)第六章:楼梯平法识图规则与标准构造详图及三维示意图6.1AT型楼梯平面注写方式与适用条件 (86)6.2AT型楼梯板配筋构造 (88)6.3BT型楼梯平面注写方式与适用条件 (89)6.4BT型楼梯板配筋构造 (91)6.5CT型楼梯平面注写方式与适用条件 (92)6.6CT型楼梯板配筋构造 (94)6.7DT型楼梯平面注写方式与适用条件 (95)6.8DT型楼梯板配筋构造 (97)6.9ET型楼梯平面注写方式与适用条件 (98)6.10ET型楼梯板配筋构造 (99)6.11FT型楼梯平面注写方式与适用条件 (100)6.12FT型楼梯板配筋构造(A-A) (101)6.13FT型楼梯板配筋构造(B-B) (102)6.14GT型楼梯平面注写方式与适用条件 (103)6.15GT型楼梯板配筋构造(A-A) (104)6.16GT型楼梯板配筋抅造(B-B) (105)6.17HT型楼梯平面注写方式与适用条件. (106)6.18HT型楼梯板配筋构造(A-A) (107)6.19HT型楼梯板配筋构造(B-B) (108)6.20C-C,D-D剖面楼梯平板配筋构造 (109)6.21ATa型楼梯平面注写方式与适用条件 (110)6.22ATa型楼梯板配筋构造 (111)6.23ATb型楼梯平面注写方式与适用条件 (112)6.24ATb型楼梯板配筋构造 (113)6.25ATc型楼梯平面注写方式与适用条件 (114)6.26ATc型楼梯板配筋构造 (116)6.27不同踏步位度推高与高度减小构造 (117)6.28各型楼梯第一跑与基础连接构造 (118)6.29楼梯施工图剖面注写示例(平面图) (119)6.30楼梯施工图剖面注写示例(剖面图) (120)6.31Ata型楼梯施工图剖面注写示例(平面图) (121)6.32Ata型楼梯施工图剖面注写示例(剖面图) (122)6.33Atb型楼梯施工图剖面注写示例(平面图) (123)6.34Atb型楼梯施工图剖面注写示例(剖面围) (124)6.35ATc型楼梯施工图剖面注写示例1(平面图) (125)6.36ATc型楼梯施工图剖面注写示例1(剖面图) (126)6.37ATc型楼梯施工图剖面注写示例2(平面图) (127)6.38ATc型楼梯施工图剖面注写示例2(剖面图) (128)第七章:基础平法标准构造详图及三维示意图任务一:独立基础平法标准构造详图及三维示意图7.1独立基础DJ J、DJ P、BJ J、BJ P底板配筋构造 (130)7.2双柱普通独立基础底部与顶部配筋构造 (131)7.3设置基础梁的双柱普通独立基础配筋构造 (132)7.4独立基础底板配筋长度减短10%构造 (133)7.5单杯口和双杯口独立基础构造 (134)7.6高杯口独立基础杯壁和基础短柱配筋构造 (135)7.7双高杯口独立基础杯壁和基础短柱配筋构造 (136)7.8单柱普通独立深基础短柱配筋构造 (137)7.9双柱普通独立深基础短柱配筋构造 (138)任务二:条形基础平法标准构造详图及三维示意图7.10条形基础底板 TJB J 和 TJB P配筋构造 (139)7.11条形基础底板配筋长度减短10%构造条形基础板底不平构造条形基础无交接底板端部构造 (140)7.12基础梁 JL 纵向钢筋与箍筋构造附加箍筋构造附加(反扣)吊筋构造 (141)7.13基础梁 JL 配置两种箍筋构造 (142)7.14基础梁 JL 竖向加腋钢筋构造 (143)7.15基础梁 JL 端部与外伸部位钢筋构造 (144)7.16基础梁 JL 侧面构造纵筋和拉筋 (145)7.17基础梁 JL 梁底不平和变截面部位钢筋构造 (146)7.18基础梁 JL 与柱结合部侧腋构造 (147)7.19基础次梁 JCL 纵向钢筋与箍筋构造基础次梁 XL 端部外伸部位钢筋构造 (148)7.20基础次梁 JCL 竖向加腋钢筋构造基础次梁 JCL 配置两种箍筋构造 (149)7.21基础次梁 JCL 梁底不平和变截面部位钢筋构造 (150)任务三:筏形基础平法标准构造详图及三维示意图7.22梁板式筏形基础平板 LPB 钢筋构造 (151)7.23梁板式筏形基础平板LPB下部柱向区域与跨中区域钢筋构造 (152)7.24梁板式筏形基础平板 LPB 端部与外伸部位钢筋构造梁板式筏形基础平板 LPB 变截面部位钢筋构造 . (153)7.25平板式筏基柱下板带ZXB与跨中板带 KZB 纵向钢筋构造 (154)7.26平板式筏形基础平板BPB钢筋构造 (156)7.27平板式筏形基础平板(ZXB、KZB、BPB)变截面部位钢筋构造 (158)7.28平板式筏形基础平板(ZXB、KZB、BPB)端部与外伸部位钢筋构造 (159)任务四:桩基础承台平法标准构造详图及三维示意图7.29矩形承台CT J和CT P配筋构造桩顶纵筋在承台内的锚固构造 (160)7.30等边三桩承台CT J配筋构造 (161)7.31等腰三桩承台CT J配筋构造 (162)7.32六边形承台CT J筋构造 ......... (163)7.33墙下单排桩承台梁C TL配筋构造 (165)7.34墙下双排桩承台梁CTL配筋构造` (166)任务五基础相关构造的平法标准构造详图及三维示意图7.35基础联系梁JLL配筋构造 (167)7.36基础底板后浇带HJD构造基础梁后浇带HJD构造 (168)7.37后浇带HJD下抗水压垫层构造后浇带HJD超前止水构造基坑JK构造 (169)7.38上柱墩SZD构造(棱台与棱柱形) (170)7.39下柱墩X ZD构造(倒棱台与倒棱柱形) (171)7.40防水底板JB与各类基础的连接构造 (173)7.41窗井墙CJQ配筋构造 (174)审核校对设计页图集号16G101-1-56-7-混凝土结构的环境类别混凝土保护层的最小厚度审核校对设计页图集号16G101-1-57-8-受拉钢筋基本锚固长度Lab抗震设计时受拉钢筋基本锚固长度labE 钢筋弯折时的弯弧D审核校对设计页图集号16G101-1-58-8-受拉钢筋基本锚固长度La 受拉钢筋基本锚固长度La E审核校对设计页图集号16G101-1-59-8-纵向钢筋弯钩与机械锚固形式纵向受力钢筋搭接区箍筋构造纵向钢筋的连接审核校对设计页图集号16G101-1-60-8-纵向受拉钢筋搭接长度 ll纵向受拉钢筋搭接长度 LL E图集号16G101-1-61封闭箍筋及拉筋构造梁并筋等效直径、最小净距离图集号16G101-1-62梁柱纵筋及间距要求拉筋构造螺旋箍筋构造第二章:柱平法标准构造详图及三维示意图图集号16G101-1-63KZ 纵向钢筋连接构造柱纵向钢筋焊接连接三维示意图非连接区域≥Hn/3搭接长度为非连接区域非连接区域嵌固体部位≥Hn/6≥搭接接头要错开≥0搭接长度为≥Hn/6≥搭接长度为搭接接头要错开≥0.搭接长度为≥Hn/6≥≥Hn/6≥连接区域采用焊接方式两批接头之间错开连接区域采用焊接方式两批接头之间错开≥Hn/6≥Hn/6≥≥Hn/6上柱比下柱多出钢筋伸长锚固到下柱中锚2La E1.2La E非连接区域Hn/6≥500≥hc 搭接长度为L LE 搭接接头要错.3L LE搭接长度为L LE 下柱较大直径钢筋伸入上柱超过上柱非连接区域与上柱较小径钢筋按百分之搭接长度为上柱较大直径钢筋伸入下柱超过下柱非连接区域与下柱较小径钢筋按百分之率搭接长度为非连接区域≥500≥500搭接接头要错L LE L LE下上柱比伸长锚固到固长度为1伸入长度1.2La E嵌固体部位非连接区域非连接区域连接区域采用焊接方式两批接头之间错开非连接区域连接区域采用焊接方式两批接头之间错开Hn/3≥Hn/6≥Hn/6≥Hn/6≥Hn/6楼面楼面柱纵向钢筋机械连接三维示意图柱纵向钢筋绑扎连接三维示意图嵌固体部位非连接区域≥Hn/3非连接区域楼面非连接区域楼面当某层连接区的高度小于纵筋分两批搭接所需要的高度时,应改用机械连接或焊接连接。
16g101平法图集_钢筋的连接方式搭接长度与相关规定(第二节)

16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—因构件构造要求或施工安装需要而配置的构造筋。
如腰筋、预埋锚固筋、预应力筋,环等。
二、钢筋的连接方式钢筋的三种连接方式及要求施工现场钢筋的4种焊接方式绑扎搭接、机械搭接和焊接三种各自的特点常用焊接方法包括电阻点焊、闪光对焊、电渣压力焊、气压焊、电弧焊,使用者应注意:1.电阻点焊:用于钢筋焊接骨架和钢筋接网。
焊接骨架较小钢筋直径不大于10mm时,大小钢筋直径之比不宜大于3倍;较小直径为12~16mm时,大小钢筋直径之比不宜大于2倍。
焊接网较小钢筋直径不得小于较大直径的60%。
2.闪光对焊:钢筋直径较小,钢筋牌号较低,在《钢筋焊接及验收规程》JGJ 18-2012表4.3.2规定的范围内,可采用“连续闪光焊”;当钢筋直径超过该规程4.3.2规定,端面较平整时,宜采用“预热闪光焊”;当钢筋直径超过规程4.3.2规定且端面不平整时,应采用“闪光-预热闪光焊”连续闪光对焊所能焊接的钢筋直径上限应根据焊接容量,钢筋牌号等具体情况而定,并应符合该规定表4.3.2的要求。
g平法图集钢筋连接方式搭接长及相关规定第二节

16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—“连续闪光焊”“预热闪光焊”“闪光-预热闪光焊”°)钢筋。
不同直径钢筋焊接时径差不得超过7mm。
4.气压焊:可用于钢筋在垂直位置,水平位置或倾斜位置的对接焊接。
不同直径钢筋焊接时径差不得超过7mm。
5.电弧焊:包括帮条焊、搭接焊、坡口焊、窄间隙焊和熔槽帮条焊。
帮条焊、熔槽帮条焊使用时应注意钢筋间隙的要求。
窄间隙焊用于直径大于等于16mm钢筋的现场水平连接。
熔槽帮条焊用于直径大于等于20mm钢筋的现场安装焊接。
三、施工现场的一般习惯做法:1.竖向构件D>16的时候一般采用电渣压力焊;2.平法规定框架柱纵向钢筋直径大于28的时候,不易采用绑扎搭接;3.如做预算的:出现不同形式连接(冲突时),以施工设计总说明为准,也就是以施工设计图纸中为准。
6G101平法图集-钢筋的连接方式、搭接长度及相关规定

6G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—因构件构造要求或施工安装需要而配置的构造筋。
如腰筋、预埋锚固筋、预应力筋,环等。
二、钢筋的连接方式钢筋的三种连接方式及要求施工现场钢筋的4种焊接方式绑扎搭接、机械搭接和焊接三种各自的特点常用焊接方法包括电阻点焊、闪光对焊、电渣压力焊、气压焊、电弧焊,使用者应注意:1.电阻点焊:用于钢筋焊接骨架和钢筋接网。
焊接骨架较小钢筋直径不大于10mm时,大小钢筋直径之比不宜大于3倍;较小直径为12~16mm时,大小钢筋直径之比不宜大于2倍。
焊接网较小钢筋直径不得小于较大直径的60%。
2.闪光对焊:钢筋直径较小,钢筋牌号较低,在《钢筋焊接及验收规程》JGJ 18-2012表4.3.2规定的范围内,可采用“连续闪光焊”;当钢筋直径超过该规程4.3.2规定,端面较平整时,宜采用“预热闪光焊”;当钢筋直径超过规程4.3.2规定且端面不平整时,应采用“闪光-预热闪光焊”连续闪光对焊所能焊接的钢筋直径上限应根据焊接容量,钢筋牌号等具体情况而定,并应符合该规定表4.3.2的要求。
16G101图集平法识图与钢筋计算PPT G901-2

2022/1/26
38
9)梁侧面钢筋(腰筋)的排布
(1)梁腹板高度 hw≥450mm时(板底至下部钢筋合 力点),需要设置构造腰筋G,腰筋间距不宜大于 200mm;
(2)抗扭纵向钢筋N应在梁侧面均匀对称布置(梁 四角也为抗扭腰筋),间距不应大于200mm及梁的 短边尺寸;
2022/1/26
39
3)拉结钢筋的排布及构造
(1)梁端均做135°弯钩,同时拉住腰筋及箍筋;
(2)设计文件无特殊要求时,间距为箍筋间距的2 倍,竖向交错布置;
(3)抗震框架梁,弯钩后的直线段为10d,其他情 况为5d(与腰筋的性质无关);
2022/1/26
40
A.角柱上、下纵向钢筋一侧直线锚固,另一侧弯折 锚固钢筋排布及构造。
2022/1/26
2022/1/26
12
唐山地震节点区未配置箍筋破坏
2022/1/26
13
柱端箍筋未作加密
2022/1/26
14
纵向钢筋搭接、箍筋未加密、未做复合箍筋
2022/1/26
15
g)穿层柱箍筋加密区按几何尺寸计算柱净高;
h)一个方向无框架梁时箍筋加密区柱净高计算方 法; i)错层节点核心区范围。
2022/1/26
41
B.边、角柱上、下纵向钢筋弯折锚固,竖直段不重 叠钢筋排布及构造(水平段足够)。
2022/1/26
42
C.边、角柱上、下纵向钢筋弯折锚固,为保证水平 段长度,竖直段重叠钢筋排布及构造。
2022/1/26
43
D.楼层端节点,梁纵向钢筋端部加锚板的锚固钢筋排 布构造做法,长度是含锚板厚度在内,宜伸至柱竖 向钢筋内侧。
度相同)
1)框架梁上部钢筋宜按主框架梁(或长方向)在 上部,另一方向自然弯曲在下部排布;
16G101图集中常见钢筋节点做法

16G101图集中常见钢筋节点做法2018年12月1日目录•一、钢筋保护层。
•二、钢筋锚固长度和搭接长度•三、钢筋弯钩及箍筋、拉筋构造•四、柱主要节点钢筋构造•五、剪力墙钢筋构造•六、梁钢筋构造•七、板钢筋构造•八、楼梯钢筋构造•九、基础钢筋构造• 1、桩基钢筋构造;• 2、基础后浇带钢筋构造。
•十、关于钢筋端头弯钩长度总结一、钢筋保护层•1、钢筋保护层定义•钢筋保护层厚度是指最外层钢筋外边缘至混凝土表面的距离。
•2、混凝土强度等级不大于C25时,保护层厚度数值应增加5。
•3、基础底面钢筋保护层厚度,有混凝土垫层时应从垫层顶面算起,且不应小于40。
•梁山龙城水景苑:•济宁龙城公馆高层:•泗水龙城水景苑:25•桩基:三、钢筋弯钩及箍筋、拉筋构造四、柱主要节点钢筋构造(P63-P70)•1、KZ钢筋构造16G101-1 P63-P66页,见16G101-1三维图集。
•2、KZ边柱和角柱柱顶纵向钢筋构造(16G101-1 P67页)•2、柱纵向钢筋在基础中构造(16G101-3 P66页)•五、剪力墙钢筋构造•1、水平分布钢筋构造 (16G101-1 P71-P72页,见三维图集)2、竖向钢筋构造(16G101-1 P73-P74页,见三维图集)3、约束性边缘构件YBZ、构造边缘构件GBZ及暗柱AZ等•3.1、水平分布筋计入约束性边缘构件体积配筋率钢筋构造做法:•①、注1中做法(一般在图纸墙体平面图中标明):济宁龙城公馆18G901-1 P3-6页学习。
•3.2、构造边缘构件GBZ、扶壁柱FBZ、非边缘暗柱AZ构造(P77页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•5、边缘构件纵向钢筋在基础中构造(16G101-3 P65页)•6、剪力墙洞口补强构造•关于预留孔洞问题:济宁龙城公馆27#楼泗水水景苑20#楼 洞口小于150mm•1.梁上预留洞2.剪力墙上预留洞泗水水景苑梁上水景苑对于剪力墙上开洞说明3.结构板上预留洞泗水水景苑20#楼济宁龙城公馆27#楼•六、梁钢筋构造16G101-1 P84-98页•七、板钢筋构造16G101-1 P99-115页•八、楼梯钢筋构造16G101-2 P23-65页1、桩基钢筋构造16G101-3 P102-104页济宁孝养城B 地块梁山龙城水景苑•九、基础钢筋构造16G101-3 P64-101页•1、桩基钢筋构造16G101-3 P102-104页•2、基础后浇带钢筋构造16G101-3 P106-107页济宁孝养城B 地块泗水龙城水景苑济宁龙城公馆嘉祥龙城华府2、基础后浇带钢筋构造16G101-3 P106-107页梁后浇带两侧1m范围内箍筋加密十、关于钢筋端头弯钩长度总结1、柱竖向钢筋底部弯钩:(1)柱钢筋伸入基础底板内,满足锚固长度:6d且≥150;不满足锚固长度:15d。
16G101图集平法制图规则及计算深度解读

16G101图集柱平法制图规则及计算深度解读图集相当于字典,查起来方便,读起来费劲,有时候读了多遍也理解不了,如果理解不了,你将无法查询,从今天开始,我帮大家深度解读16G图集,帮大家节省时间。
大家看一下,同图表示,你是不是对平法是什么,有了更好的理解。
16G图集这次最大的变化就是取消了非抗震情况,就是因为有了以上这份文件。
至于16G101-1和-2包括哪些内容,我们后面再讲,慢慢来!“框架-剪力墙结构”和“框支剪力墙结构”我理解是否正确,欢迎大家拍砖。
虽然现在平法图集上没有陈教授的名字,但是我们不能忘记这个人,他发明平法,解放了无数建筑工作者的劳动力。
别把图集当规范,平法图集是从规范衍生出来应用工具。
简单来说,平法施工图=平面图+标准构造详图,这里平面图是按照平法规则绘制出来的。
这几种方式,我们后面会详细解读。
图纸说明大多数对预算员没用,做预算不要把时间浪费在图纸说明上。
这些地方设计如果不注明,就证明是设计新手干的,找老预算员取取经验,别瞎做。
哈哈!先来一波更新^.^【2016年11月7日】其实芯柱的内容,16G平法图集并没有单独拿出来,因为网上很多人问这个问题,我在这里特意拿出来单独解读。
列表注写方式图上有个特点,就是柱截面标注的不是具体尺寸,是参数代号,具体尺寸要从表里查得。
注意,偏轴时图中参数可以是负值。
这里注意大家按照我给的序号顺序看。
关于转换柱的具体内容,我们后面会详细解读。
常用的箍筋是类型1和类型2。
我们经常碰到复合箍筋,不知道怎么拆分,有了这个原则就知道怎么拆分了。
大家注意,柱子的箍筋是“几×几”,梁的箍筋一般叫“几肢箍”。
大家注意,芯柱不会单独存在,一定和框架柱在一起,尺寸标注方式随框架柱。
为了施工方便,这张表平法图集要求至少在柱、墙、梁结构图上放置这张表。
大家注意,这张表里的标高表示的是当前层的结构底标高,而不是建筑底标高,平法图集里讲的所有标高,都是结构标高不是建筑标高。
16G101钢筋教程讲义-第二章 独立基础平法识图及钢筋计算

16G101-3P57
独立基础钢筋一般构造
独立基础钢筋一般构造
独立基础钢筋一般构造
三、受拉钢筋基本锚固长度
受拉钢筋基本锚固长度Lab、Labe 受拉钢筋锚固长度La、Lae
独立基础钢筋一般构造
受拉钢筋基本锚固长度Lab、锚固长度La
d是否 大于25
16G101-3P57
第五节 独立基础底部边长≥2500时
配筋构造及案例
目录
一、配筋构造 二、配筋计算
配筋构造及案例
16G101-3P70
配筋构造及案例
配筋构造及案例
配筋构造及案例
配筋构造及案例
第六节 独立基础顶部配筋构造及案例
目录
一、独立基础顶部配筋构造 二、独立基础顶部配筋计算
独立基础顶部配筋构造及案例
独立基础钢筋一般构造
独立基础钢筋一般构造
第四节 独立基础底板配筋构造及案例
目录
一、独立基础底板配筋构造 二、独立基础底板配筋计算
独立基础底板配筋构造及案例
一、独立基础底板配筋构造
独立基础底板配筋构造及案例
独立基础底板配筋构造及案例
16G101-3P67
独立基础底板配筋构造及案例
独立基础底板配筋构造及案例
独立基础平法表示
独立基础 平法表示方法
平面注写
截面注写
集中标注
原位标注 截面标注 列表注写
必注内容
基础编号(DJj、DJp)
截面竖向尺寸 (h1/h2…)
配筋(B:X&Y,T)
选注内容
基础底面标高 必要的文字注解
独立基础的平面尺寸
独立基础平法表示
16G101-3P12、13
16G101钢筋计算的步骤以及方法

目录1、总说明 (3)2、钢筋算量基本方法小结 (5)2.1、梁 (5)2.1.1 框架梁 (5)2.1.2、其他梁 (16)2.2、剪力墙 (17)2.2.1 剪力墙墙身 (18)2.2.2剪力墙墙柱 (20)2.2.3 剪力墙墙梁 (21)2.3、柱 (21)2.3.1、基础层 (21)2.3.2 、中间层 (22)2.3.3、顶层 (22)2.4、板 (24)3、常见问题 (31)3.1.●柱问题 (31)3.2●梁问题 (35)3.3●墙问题 (51)3.4●钢筋全套知识 (63)3.5●钢筋常用的分类 (77)3.6●混凝土保护层 (78)3.6●钢筋锚固 (80)3.7●交叠钢筋上下位置的确定 (133)刚性地面的概述 (137)对于刚性地面的几种不同理解 (137)工程施工角度 (137)结构设计角度 (137)《建筑抗震设计规范》中定义的刚性地面 (138)《建筑地面与楼面手册》中定义的刚性地面 (138) (138)剪跨比 ................................................................. 错误!未定义书签。
对11G101-1图集中机械锚固的疑问 (143)2.钢筋施工工艺 (146)1.为什么钢筋计算中,135°弯钩我们在软件中计算为11.9d? (158)2、后浇带 (158)1、总说明手工计算钢筋的步骤以及方法:首先要说明的一点是,我们平时所说的钢筋预算和实际的钢筋下料是不一样的。
我们所说的钢筋预算就是按照建筑的规范或标准平法图集的要求计算出来的钢筋。
而下料还要考虑很多施工现场的要求,例如我们的钢筋断点的位置在实际的施工中是有规定的,必须断在跨中1/3 的范围内,构件交错的地方要注意钢筋的避让等。
在我们拿到结构图纸后,首先分析此建筑是什么结构形式、大致有哪些构件、基础是什么类型。
然后我们一般剪力墙按照从下向上的顺序,也就是施工的先后顺序进行计算。
16G101三维图集学习教程(全本)_1-50

16建筑三维平法结构识图教程序各位尊敬的读者朋友们,感谢大家选择《16建筑三维平法结构识图教程》,建筑工程中建筑结构识图和建筑钢筋工程算量是重要的专业能力。
无论是在施工、造价,还是工程管理,我们都离不开对目录第一章:钢筋锚固长度及其相关规范1.1受拉钢筋基本锚固长度L ab ,L abE受拉钢筋锚固长度修正系数·····························1.2混凝土结构的环境类别混凝土保护层的最小厚度(mm )纵向受力钢筋搭接区箍筋构造 ·····························1.3纵向钢筋弯钩与机械锚固形式纵向受拉钢筋綁扎搭接长度L L 、L LE ··························1.4封闭箍筋及拉筋弯钩构造梁并筋等效直径、最小净距梁柱纵筋间距要求螺旋箍筋构造 ·································1.5封闭箍筋及拉筋弯钩构造基础梁箍筋复合方式非接触纵向钢筋搭接构造·····························································第二章:柱平法标准构造详图及三维示意图2.1·······························2.2抗震KZ 纵向钢筋连接构造······························2.3地下室抗震KZ 的纵向钢筋连接构造、地下室抗震KZ 的箍筋加密区范围 ··························2.4抗震框架柱和角柱柱顶纵向钢筋构造·························2.5抗震KZ 中柱顶纵向钢筋构造······························2.6抗震KZ 柱变截面位置纵向钢筋构造···························2.7抗震KZ 、QZ 、LZ 箍筋加密区范围抗震QZ 、LZ 纵向钢筋构造 ······························2.8抗震框架柱和小墙肢箍筋加密区高度选用表·······················2.9非抗震KZ 纵向钢筋连接构造·····························2.10非抗震KZ 边柱和角柱柱顶纵向钢筋构造························2.11非抗震KZ 中柱顶纵向钢筋构造····························2.12非抗震KZ 柱变截面位置纵向钢筋构造·························2.13非抗震KZ 箍筋构造非抗震QZ 、LZ 纵向钢筋构造······························第三章:剪力墙平法标准构造详图及三维示意图3.1剪力墙身水平钢筋构造................................27.. (31)3.3剪力墙身竖向钢筋构造 (32)3.4约束边缘构件YBZ 构造 (35)3.5剪力墙水平钢筋计入约束边缘构件体积配箍率构造做法 (37)3.6构造边缘构件GBZ 、扶壁柱FBZ 、非边缘暗柱AZ 构造剪力墙边缘构件纵向钢筋连接构造剪力墙约束边缘构件纵筋构造 (38)3.8剪力墙 LL /AL BKL 配筋构造 (39)3.9剪力墙BKL 或AL 与LL 重叠时配筋构造··························403.10连梁交叉斜筋配筋LL (JX )连梁集中对角斜筋配筋LL (DX )连梁对角暗撑配筋LL (JC )构造 (42)3.11地下室外墙DWQ 钢筋构造...............................433.12剪力墙洞口补强构造 .. (45)第四章:梁平法标准构造详图及三维示意图 (47)4.2抗震屋面框架梁WKL 纵向钢筋构造 (48)4.3非抗震楼层框架梁KL 纵向钢筋构造 (49)4.4非抗震屋面框架梁WKL 纵向钢筋构造 .........................504.5框架梁水平、竖向加腋构造.. (51)ζa 1.6芯柱XZ 配筋构造矩形箍筋复合方式柱插筋在基础中的锚固3.2墙插筋在基础中的锚固4.1抗震楼层框架梁WKL纵向钢筋构造4.6KL 、WKL中间支座纵向钢筋构造 (53)4.7抗震框架梁KL、WKL箍筋加密区构造抗震框架梁KL、WKL箍筋加密区构造 (54)4.8梁与方柱斜交或与圆柱相交时箍筋起始位置 (55)4.9非框架梁L配筋构造主次梁斜交箍筋构造 (56)4.10不伸入支座的梁下部纵向钢筋断点位置附加箍筋范围、附加吊筋构造梁侧面纵向构造筋和拉筋 (57)4.11非框架梁L中间支座纵向钢筋构造水平折梁、竖向折梁钢筋构造 (58)4.12纯悬挑梁XL及各类梁的悬挑端配筋构造 (59)4.13KZZ/KZL配筋构造 (51)4.14井字梁JZL配筋构造 (65)第五章:板平法标准构造详图及三维示意图5.1有梁楼盖楼(屋)面板配筋构造 (67)5.2有梁楼盖不等跨板上部贯通纵筋连接构造 (69)5.3单(双)向板配筋示意纵向钢筋非接触搭接构造 (70)5.4悬挑板XB钢筋构造 (71)5.5无支撑板端部封边构造折板配筋构造 (72)5.6无梁楼盖柱上板带ZSB与跨中板带KZB纵向钢筋构造 (73)5.7板带端支座纵向钢筋构造板带悬挑端纵向钢筋构造 (74)5.8柱上板带暗梁钢筋构造 (75)5.9板后浇带HJD钢筋构造墙后浇带HJD钢筋构造梁后浇带HJD钢筋构造 (76)5.10板加腋JY构造局部升降板SJB构造(一) (77)5.11板加腋JY构造局部升降板SJB构造(二) (78)5.12板开洞BD与洞边加强钢筋构造一(洞边无集中荷载) (79)5.13板开洞BD与洞边加强钢筋构造二(洞边无集中荷载) (80)5.14悬挑板阳角放射筋Ces构造 (81)5.15板内纵筋加强带JQD构造板翻边FB构造悬挑板阴角构造 (82)5.16柱帽ZMa、ZMb,ZMc、ZMab构造 (83)5.17抗冲切箍筋Rh构造抗冲切弯起筋Rb构造 (84)第六章:楼梯平法识图规则与标准构造详图及三维示意图6.1AT型楼梯平面注写方式与适用条件 (86)6.2AT型楼梯板配筋构造 (88)6.3BT型楼梯平面注写方式与适用条件 (89)6.4BT型楼梯板配筋构造 (91)6.5CT型楼梯平面注写方式与适用条件 (92)6.6CT型楼梯板配筋构造 (94)6.7DT型楼梯平面注写方式与适用条件 (95)6.8DT型楼梯板配筋构造 (97)6.9ET型楼梯平面注写方式与适用条件 (98)6.10ET型楼梯板配筋构造 (99)6.11FT型楼梯平面注写方式与适用条件 (100)6.12FT型楼梯板配筋构造(A-A) (101)6.13FT型楼梯板配筋构造(B-B) (102)6.14GT型楼梯平面注写方式与适用条件 (103)6.15GT型楼梯板配筋构造(A-A) (104)6.16GT型楼梯板配筋抅造(B-B) (105)6.17HT型楼梯平面注写方式与适用条件. (106)6.18HT型楼梯板配筋构造(A-A) (107)6.19HT型楼梯板配筋构造(B-B) (108)6.20C-C,D-D剖面楼梯平板配筋构造 (109)6.21ATa型楼梯平面注写方式与适用条件 (110)6.22ATa型楼梯板配筋构造 (111)6.23ATb 型楼梯平面注写方式与适用条件 (112)6.24ATb 型楼梯板配筋构造...............................1136.25ATc 型楼梯平面注写方式与适用条件. (114)6.26ATc 型楼梯板配筋构造 (116)6.27不同踏步位度推高与高度减小构造 (117)6.28各型楼梯第一跑与基础连接构造 (118)6.29楼梯施工图剖面注写示例(平面图) (119)6.30楼梯施工图剖面注写示例(剖面图) (120)6.31 Ata 型楼梯施工图剖面注写示例(平面图) (121)6.32 Ata 型楼梯施工图剖面注写示例(剖面图) (122)6.33 Atb 型楼梯施工图剖面注写示例(平面图) (123)6.34 Atb 型楼梯施工图剖面注写示例(剖面围) (124)6.35 ATc 型楼梯施工图剖面注写示例1(平面图) (125)6.36 ATc 型楼梯施工图剖面注写示例1(剖面图) (126)6.37 ATc 型楼梯施工图剖面注写示例2(平面图) (127)6.38 ATc 型楼梯施工图剖面注写示例2(剖面图) (128)第七章:基础平法标准构造详图及三维示意图任务一:独立基础平法标准构造详图及三维示意图7.1独立基础DJ J 、DJ P 、BJ J 、BJ P 底板配筋构造 (130)7.2双柱普通独立基础底部与顶部配筋构造 (131)7.3设置基础梁的双柱普通独立基础配筋构造.......................1327.4独立基础底板配筋长度减短10%构造.........................1337.5单杯口和双杯口独立基础构造. (134)7.6高杯口独立基础杯壁和基础短柱配筋构造 (135)7.7双高杯口独立基础杯壁和基础短柱配筋构造......................136独立深基础短柱配筋构造.. (137)7.9双柱普通独立深基础短柱配筋构造··························138任务二:条形基础平法标准构造详图及三维示意图7.10条形基础底板 TJB J 和 TJB P 配筋构造························1397.11条形基础底板配筋长度减短10%构造条形基础板底不平构造条形基础无交接底板端部构造 (140)7.12基础梁 JL 纵向钢筋与箍筋构造附加箍筋构造附加(反扣)吊筋构造 (141)7.13基础梁 JL 配置两种箍筋构造 (142)7.14基础梁 JL 竖向加腋钢筋构造 (143)7.15基础梁 JL 端部与外伸部位钢筋构造 (144)7.16基础梁 JL 侧面构造纵筋和拉筋 (145)7.17基础梁 JL 梁底不平和变截面部位钢筋构造 (146)7.18基础梁 JL 与柱结合部侧腋构造 (147)7.19基础次梁 JCL 纵向钢筋与箍筋构造基础次梁 XL 端部外伸部位钢筋构造 (148)7.20基础次梁 JCL 竖向加腋钢筋构造基础次梁 JCL 配置两种箍筋构造 (149)7.21基础次梁 JCL 梁底不平和变截面部位钢筋构造····················150任务三:筏形基础平法标准构造详图及三维示意图7.22梁板式筏形基础平板 LPB 钢筋构造 (151)7.23梁板式筏形基础平板LPB 下部柱向区域与跨中区域钢筋构造 (152)7.24梁板式筏形基础平板 LPB 端部与外伸部位钢筋构造梁板式筏形基础平板 LPB 变截面部位钢筋构造 . (153)7.25平板式筏基柱下板带ZXB 与跨中板带 KZB 纵向钢筋构造 (154)7.26平板式筏形基础平板BPB 钢筋构造 (156)7.27平板式筏形基础平板(ZXB 、KZB 、BPB )变截面部位钢筋构造 (158)7.28平板式筏形基础平板(ZXB 、KZB 、BPB )端部与外伸部位钢筋构造 (159)7.8单柱普通任务四:桩基础承台平法标准构造详图及三维示意图7.29矩形承台CT J和CT P配筋构造桩顶纵筋在承台内的锚固构造 (160)7.30等边三桩承台CT J配筋构造 (161)7.31等腰三桩承台CT J配筋构造 (162)7.32六边形承台CT J筋构造 ......... (163)7.33墙下单排桩承台梁C TL配筋构造 (165)7.34墙下双排桩承台梁CTL配筋构造` (166)任务五基础相关构造的平法标准构造详图及三维示意图7.35基础联系梁JLL配筋构造 (167)7.36基础底板后浇带HJD构造基础梁后浇带HJD构造 (168)7.37后浇带HJD下抗水压垫层构造后浇带HJD超前止水构造基坑JK构造 (169)7.38上柱墩SZD构造(棱台与棱柱形) (170)7.39下柱墩X ZD构造(倒棱台与倒棱柱形) (171)7.40防水底板JB与各类基础的连接构造 (173)7.41窗井墙CJQ配筋构造 (174)第一章:钢筋锚固长度及其相关规范审核校对设计页图集号16G101-1-56-7-混凝土结构的环境类别混凝土保护层的最小厚度审核校对设计页图集号16G101-1-57-8-受拉钢筋基本锚固长度Lab抗震设计时受拉钢筋基本锚固长度labE 钢筋弯折时的弯弧D图集号16G101-1-58受拉钢筋基本锚固长度La受拉钢筋基本锚固长度La E图集号16G101-1-59纵向钢筋弯钩与机械锚固形式纵向受力钢筋搭接区箍筋构造纵向钢筋的连接纵向受拉钢筋搭接长度 ll图集号16G101-1-60纵向受拉钢筋搭接长度 LL E图集号16G101-1-61图集号16G101-1-62封闭箍筋及拉筋构造梁并筋等效直径、最小净距离梁柱纵筋及间距要求拉筋构造螺旋箍筋构造第二章:柱平法标准构造详图及三维示意图图集号16G101-1-63KZ 纵向钢筋连接构造柱纵向钢筋焊接连接三维示意图非连接区域≥Hn/3搭接长度为非连接区域非连接区域嵌固体部位≥Hn/6≥搭接接头要错开≥0搭接长度为≥Hn/6≥搭接长度为搭接接头要错开≥0.搭接长度为≥Hn/6≥≥Hn/6≥连接区域采用焊接方式两批接头之间错开连接区域采用焊接方式两批接头之间错开≥Hn/6≥Hn/6≥≥Hn/6上柱比下柱多出钢筋伸长锚固到下柱中锚2La E1.2La E非连接区域Hn/6≥500≥hc 搭接长度为L LE 搭接接头要错.3L LE搭接长度为L LE 下柱较大直径钢筋伸入上柱超过上柱非连接区域与上柱较小径钢筋按百分之搭接长度为上柱较大直径钢筋伸入下柱超过下柱非连接区域与下柱较小径钢筋按百分之率搭接长度为非连接区域≥500≥500搭接接头要错L LE L LE下上柱比伸长锚固到固长度为1伸入长度1.2La E嵌固体部位非连接区域非连接区域连接区域采用焊接方式两批接头之间错开非连接区域连接区域采用焊接方式两批接头之间错开Hn/3≥Hn/6≥Hn/6≥Hn/6≥Hn/6楼面楼面柱纵向钢筋机械连接三维示意图柱纵向钢筋绑扎连接三维示意图嵌固体部位非连接区域≥Hn/3非连接区域楼面非连接区域楼面当某层连接区的高度小于纵筋分两批搭接所需要的高度时,应改用机械连接或焊接连接。
16g101平法图集-钢筋的连接方式搭接长度及相关规定(第二节)

16g101平法图集-钢筋的连接方式搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—因构件构造要求或施工安装需要而配置的构造筋。
如腰筋、预埋锚固筋、预应力筋,环等。
二、钢筋的连接方式钢筋的三种连接方式及要求施工现场钢筋的4种焊接方式绑扎搭接、机械搭接和焊接三种各自的特点常用焊接方法包括电阻点焊、闪光对焊、电渣压力焊、气压焊、电弧焊,使用者应注意:1.电阻点焊:用于钢筋焊接骨架和钢筋接网。
焊接骨架较小钢筋直径不大于10mm时,大小钢筋直径之比不宜大于3倍;较小直径为12~16mm时,大小钢筋直径之比不宜大于2倍。
焊接网较小钢筋直径不得小于较大直径的60%。
2.闪光对焊:钢筋直径较小,钢筋牌号较低,在《钢筋焊接及验收规程》JGJ 18-2012表4.3.2规定的范围内,可采用“连续闪光焊”;当钢筋直径超过该规程4.3.2规定,端面较平整时,宜采用“预热闪光焊”;当钢筋直径超过规程4.3.2规定且端面不平整时,应采用“闪光-预热闪光焊”连续闪光对焊所能焊接的钢筋直径上限应根据焊接容量,钢筋牌号等具体情况而定,并应符合该规定表4.3.2的要求。
平法识图教材PPT-2钢筋长度

识读
16G101系列图集
12/12/2022
1
项目二 钢筋设计长度
与下料长度
2
项目二 钢筋设计长度与下料长度
任务1 计算钢筋设计长度和下料长度 任务2 计算箍筋和拉筋外皮设计尺寸 任务3 计算圆柱环状箍筋外皮长度
3
教学目标
通过对本单元的学习,学生应能够: 1.掌握钢筋计算的原理和方法。 2.熟练掌握箍筋的设计长度和施工下料长 度的计算。 3.熟练掌握拉筋的设计长度和施工下料长 度的计算。
增加长度为109。 L3=L1+109=559 (mm) L4=L2+109=359 (mm)
设计长度(外轮廓长度)计算 L=L1+L2+L3+L4 =450+250+559+359 =1618(mm)
35
2.施工下料长度(中心线长度)计算
查表2.1,R=2.5d时,90°弯钩的外皮尺寸差 值为2.288d,共3个。
33 33
L4=B-2c+3.569d+max(10d,75) =300-2×25+3.569×8+max(10×8,75) =250+28.6+80 ≈ 359(mm)
设计长度(外轮廓长度)计算 L=L1+L2+L3+L4 =450+250+559+359 =1618(mm)
34
解法2:用查表方法计算箍筋外皮尺寸 L1=H-2c=500-2×25=450 (mm) L2=B-2c=300-2×25=250 (mm) 查表2.2,R=2.5d,d=8,每个135°弯钩
14
课堂练习2.3
图示为某单跨框架梁上部通长钢筋在梁纵剖 面内的形状,2B20,HRB335级钢筋,梁截面 300×700。
已知,柱保护层厚度20,柱子外侧纵筋C22, 柱箍筋C8,梁通长筋竖向弯钩段与柱外侧纵筋之 间的净距为25;labE=laE=35d,弯曲半径R=4d。
16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)

16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第二节)16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—因构件构造要求或施工安装需要而配置的构造筋。
如腰筋、预埋锚固筋、预应力筋,环等。
二、钢筋的连接方式钢筋的三种连接方式及要求施工现场钢筋的4种焊接方式绑扎搭接、机械搭接和焊接三种各自的特点常用焊接方法包括电阻点焊、闪光对焊、电渣压力焊、气压焊、电弧焊,使用者应注意:1.电阻点焊:用于钢筋焊接骨架和钢筋接网。
焊接骨架较小钢筋直径不大于10mm时,大小钢筋直径之比不宜大于3倍;较小直径为12~16mm时,大小钢筋直径之比不宜大于2倍。
焊接网较小钢筋直径不得小于较大直径的60%。
2.闪光对焊:钢筋直径较小,钢筋牌号较低,在《钢筋焊接及验收规程》JGJ 18-2012表4.3.2规定的范围内,可采用“连续闪光焊”;当钢筋直径超过该规程4.3.2规定,端面较平整时,宜采用“预热闪光焊”;当钢筋直径超过规程4.3.2规定且端面不平整时,应采用“闪光-预热闪光焊”连续闪光对焊所能焊接的钢筋直径上限应根据焊接容量,钢筋牌号等具体情况而定,并应符合该规定表4.3.2的要求。
16G101图集中常见钢筋节点做法

16G101图集中常见钢筋节点做法2018年12月1日目录•一、钢筋保护层。
•二、钢筋锚固长度和搭接长度•三、钢筋弯钩及箍筋、拉筋构造•四、柱主要节点钢筋构造•五、剪力墙钢筋构造•六、梁钢筋构造•七、板钢筋构造•八、楼梯钢筋构造•九、基础钢筋构造• 1、桩基钢筋构造;• 2、基础后浇带钢筋构造。
•十、关于钢筋端头弯钩长度总结一、钢筋保护层•1、钢筋保护层定义•钢筋保护层厚度是指最外层钢筋外边缘至混凝土表面的距离。
•2、混凝土强度等级不大于C25时,保护层厚度数值应增加5。
•3、基础底面钢筋保护层厚度,有混凝土垫层时应从垫层顶面算起,且不应小于40。
•梁山龙城水景苑:•济宁龙城公馆高层:•泗水龙城水景苑:25•桩基:二、钢筋锚固及搭接长度三、钢筋弯钩及箍筋、拉筋构造四、柱主要节点钢筋构造(P63-P70)•1、KZ钢筋构造16G101-1 P63-P66页,见16G101-1三维图集。
•2、KZ边柱和角柱柱顶纵向钢筋构造(16G101-1 P67页)•2、柱纵向钢筋在基础中构造(16G101-3 P66页)•五、剪力墙钢筋构造•1、水平分布钢筋构造 (16G101-1 P71-P72页,见三维图集)2、竖向钢筋构造(16G101-1 P73-P74页,见三维图集)3、约束性边缘构件YBZ、构造边缘构件GBZ及暗柱AZ等•3.1、水平分布筋计入约束性边缘构件体积配筋率钢筋构造做法:•①、注1中做法(一般在图纸墙体平面图中标明):济宁龙城公馆18G901-1 P3-6页学习。
•3.2、构造边缘构件GBZ、扶壁柱FBZ、非边缘暗柱AZ构造(P77页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•5、边缘构件纵向钢筋在基础中构造(16G101-3 P65页)•6、剪力墙洞口补强构造•关于预留孔洞问题:济宁龙城公馆27#楼泗水水景苑20#楼 洞口小于150mm•1.梁上预留洞2.剪力墙上预留洞泗水水景苑梁上水景苑对于剪力墙上开洞说明3.结构板上预留洞泗水水景苑20#楼济宁龙城公馆27#楼•六、梁钢筋构造16G101-1 P84-98页•七、板钢筋构造16G101-1 P99-115页•八、楼梯钢筋构造16G101-2 P23-65页1、桩基钢筋构造16G101-3 P102-104页济宁孝养城B 地块梁山龙城水景苑•九、基础钢筋构造16G101-3 P64-101页•1、桩基钢筋构造16G101-3 P102-104页•2、基础后浇带钢筋构造16G101-3 P106-107页济宁孝养城B 地块泗水龙城水景苑济宁龙城公馆嘉祥龙城华府2、基础后浇带钢筋构造16G101-3 P106-107页梁后浇带两侧1m范围内箍筋加密十、关于钢筋端头弯钩长度总结1、柱竖向钢筋底部弯钩:(1)柱钢筋伸入基础底板内,满足锚固长度:6d且≥150;不满足锚固长度:15d。
16G101钢筋计算的步骤以及方法

目录1、总说明 (3)2、钢筋算量基本方法小结 (5)2.1、梁 (5)2.1.1 框架梁 (5)2.1.2、其他梁 (16)2.2、剪力墙 (17)2.2.1 剪力墙墙身 (18)2.2.2剪力墙墙柱 (20)2.2.3 剪力墙墙梁 (21)2.3、柱 (21)2.3.1、基础层 (21)2.3.2 、中间层 (22)2.3.3、顶层 (22)2.4、板 (24)3、常见问题 (31)3.1.●柱问题 (31)3.2●梁问题 (35)3.3●墙问题 (51)3.4●钢筋全套知识 (63)3.5●钢筋常用的分类 (77)3.6●混凝土保护层 (78)3.6●钢筋锚固 (80)3.7●交叠钢筋上下位置的确定 (133)刚性地面的概述 (137)对于刚性地面的几种不同理解 (137)工程施工角度 (137)结构设计角度 (137)《建筑抗震设计规范》中定义的刚性地面 (138)《建筑地面与楼面手册》中定义的刚性地面 (138) (138)剪跨比 ................................................................. 错误!未定义书签。
对11G101-1图集中机械锚固的疑问 (143)2.钢筋施工工艺 (146)1.为什么钢筋计算中,135°弯钩我们在软件中计算为11.9d? (158)2、后浇带 (158)1、总说明手工计算钢筋的步骤以及方法:首先要说明的一点是,我们平时所说的钢筋预算和实际的钢筋下料是不一样的。
我们所说的钢筋预算就是按照建筑的规范或标准平法图集的要求计算出来的钢筋。
而下料还要考虑很多施工现场的要求,例如我们的钢筋断点的位置在实际的施工中是有规定的,必须断在跨中1/3 的范围内,构件交错的地方要注意钢筋的避让等。
在我们拿到结构图纸后,首先分析此建筑是什么结构形式、大致有哪些构件、基础是什么类型。
然后我们一般剪力墙按照从下向上的顺序,也就是施工的先后顺序进行计算。
16G101图集中常见钢筋节点做法

16G101图集中常见钢筋节点做法2018年12月1日目录•一、钢筋保护层。
•二、钢筋锚固长度和搭接长度•三、钢筋弯钩及箍筋、拉筋构造•四、柱主要节点钢筋构造•五、剪力墙钢筋构造•六、梁钢筋构造•七、板钢筋构造•八、楼梯钢筋构造•九、基础钢筋构造• 1、桩基钢筋构造;• 2、基础后浇带钢筋构造。
•十、关于钢筋端头弯钩长度总结一、钢筋保护层•1、钢筋保护层定义•钢筋保护层厚度是指最外层钢筋外边缘至混凝土表面的距离。
•2、混凝土强度等级不大于C25时,保护层厚度数值应增加5。
•3、基础底面钢筋保护层厚度,有混凝土垫层时应从垫层顶面算起,且不应小于40。
•梁山龙城水景苑:•济宁龙城公馆高层:•泗水龙城水景苑:25•桩基:二、钢筋锚固及搭接长度三、钢筋弯钩及箍筋、拉筋构造四、柱主要节点钢筋构造(P63-P70)•1、KZ钢筋构造16G101-1 P63-P66页,见16G101-1三维图集。
•2、KZ边柱和角柱柱顶纵向钢筋构造(16G101-1 P67页)•2、柱纵向钢筋在基础中构造(16G101-3 P66页)•五、剪力墙钢筋构造•1、水平分布钢筋构造 (16G101-1 P71-P72页,见三维图集)2、竖向钢筋构造(16G101-1 P73-P74页,见三维图集)3、约束性边缘构件YBZ、构造边缘构件GBZ及暗柱AZ等•3.1、水平分布筋计入约束性边缘构件体积配筋率钢筋构造做法:•①、注1中做法(一般在图纸墙体平面图中标明):济宁龙城公馆18G901-1 P3-6页学习。
•3.2、构造边缘构件GBZ、扶壁柱FBZ、非边缘暗柱AZ构造(P77页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•墙身竖向分部钢筋在基础中构造(16G101-3 P64页)•5、边缘构件纵向钢筋在基础中构造(16G101-3 P65页)•6、剪力墙洞口补强构造•关于预留孔洞问题:济宁龙城公馆27#楼泗水水景苑20#楼 洞口小于150mm•1.梁上预留洞2.剪力墙上预留洞泗水水景苑梁上水景苑对于剪力墙上开洞说明3.结构板上预留洞泗水水景苑20#楼济宁龙城公馆27#楼•六、梁钢筋构造16G101-1 P84-98页•七、板钢筋构造16G101-1 P99-115页•八、楼梯钢筋构造16G101-2 P23-65页1、桩基钢筋构造16G101-3 P102-104页济宁孝养城B 地块梁山龙城水景苑•九、基础钢筋构造16G101-3 P64-101页•1、桩基钢筋构造16G101-3 P102-104页•2、基础后浇带钢筋构造16G101-3 P106-107页济宁孝养城B 地块泗水龙城水景苑济宁龙城公馆嘉祥龙城华府2、基础后浇带钢筋构造16G101-3 P106-107页梁后浇带两侧1m范围内箍筋加密十、关于钢筋端头弯钩长度总结1、柱竖向钢筋底部弯钩:(1)柱钢筋伸入基础底板内,满足锚固长度:6d且≥150;不满足锚固长度:15d。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
16G101平法图集-钢筋的连接方式、搭接长度及相关规定(第
二节)
16G101平法图集-钢筋的连接方式、搭接长度及规定(第二节)原创作者:头条号/西北工程人一、钢筋种类很多,通常按化学成分、生产工艺、轧制外形、供应形式、直径大小,以及在结构中的用途进行分类:1、按直径大小分钢丝(直径3~5mm)、细钢筋(直径6~10mm)、粗钢筋(直径大于22mm)。
2、按力学性能分Ⅰ级钢筋(235/420级);Ⅱ级钢筋(335/455级);Ⅲ级钢筋(400/540)和Ⅳ级钢筋(500/630)3、按生产工艺分热轧、冷轧、冷拉的钢筋,还有以Ⅳ级钢筋经热处理而成的热处理钢筋,强度比前者更高。
4、按在结构中的作用分受压钢筋、受拉钢筋、架立钢筋、分布钢筋、箍筋等。
配置在钢筋混凝土结构中的钢筋,按其作用可分为下列几种:1.受力筋—承受拉、压应力的钢筋。
2.箍筋—承受一部分斜拉应力,并固定受力筋的位置,多用于梁和柱内。
3.架立筋—用以固定梁内钢箍的位置,构成梁内的钢筋骨架。
4.分布筋—用于屋面板、楼板内,与板的受力筋垂直布置,将承受的重量均匀地传给受力筋,并固定受力筋的位置,以及抵抗热胀冷缩所引起的温度变形。
5.其它—因构件构造要求或施工安装需要而配置的构造筋。
如腰筋、预埋锚固筋、预应力筋,环等。
二、钢筋的连接方式钢筋的三种连接方式
及要求施工现场钢筋的4种焊接方式绑扎搭接、机械搭接和焊接三种各自的特点常用焊接方法包括电阻点焊、闪光对焊、电渣压力焊、气压焊、电弧焊,使用者应注意:1.电阻点焊:用于钢筋焊接骨架和钢筋接网。
焊接骨架较小钢筋直径不大于10mm时,大小钢筋直径之比不宜大于3倍;较小直径为12~16mm时,大小钢筋直径之比不宜大于2倍。
焊接网较小钢筋直径不得小于较大直径的60%。
2.闪光对焊:钢筋直径较小,钢筋牌号较低,在《钢筋焊接及验收规程》JGJ 18-2012表4.3.2规定的范围内,可采用“连续闪光焊”;当钢筋直径超过该规程4.3.2规定,端面较平整时,宜采用“预热闪光焊”;当钢筋直径超过规程4.3.2规定且端面不平整时,应采用“闪光-预热闪光焊”连续闪光对焊所能焊接的钢筋直径上限应根据焊接容量,钢筋牌号等具体情况而定,并应符合该规定表4.3.2的要求。
闪光对焊时钢筋径差不得超过4mm。
3.电渣压力焊:仅应用于柱、墙等构件中竖向或斜向(倾斜度不大于10°)钢筋。
不同直径钢筋焊接时径差不得超过7mm。
4.气压焊:可用于钢筋在垂直位置,水平位置或倾斜位置的对接焊接。
不同直径钢筋焊接时径差不得超过7mm。
5.电弧焊:包括帮条焊、搭接焊、坡口焊、窄间隙焊和熔槽帮条焊。
帮条焊、熔槽帮条焊使用时应注意钢筋间隙的要求。
窄间隙焊用于直径大于等于16mm钢筋的现场水平连接。
熔槽帮条焊用于直径大于等于20mm钢筋的现场安
装焊接。
三、施工现场的一般习惯做法:1.竖向构件D>16
的时候一般采用电渣压力焊;2.平法规定框架柱纵向钢筋直径大于28的时候,不易采用绑扎搭接;3.如做预算的:出现不同形式连接(冲突时),以施工设计总说明为准,也就是以施工设计图纸中为准。
16G101-1,P59图集中钢筋搭接,需特别注意第4条四、钢筋的搭接长度16G101-1图集中给出了表,以查表方式直接查询。
1.钢筋搭接百分率含义:指的是对于同一连接区段内纵向钢筋搭接接头面积百分率;其实也就是区段内有连接接头纵向的钢筋截面面积和全部纵
向钢筋截面面积比值。
16G101-1,P6016G101-1,P612..同一构建中相邻纵向受力钢筋的绑扎搭接接头宜相互错开。
钢筋绑扎搭接连接区段长度为1.3倍的搭接长度(1.3lt或1.3lte),凡搭接接头中点位于该连接区段长度内的搭接接头均属于
同一连接区段,见图1.8-1.同一连接区段内纵向受力钢筋搭接接头面积百分率为该区段内有搭接接头的纵向受力钢筋
与全部纵向受力钢筋截面面积比值。
同一连接区段内纵向受力钢筋搭接接头面积百分率宜满足要求。
3.直径不相同钢筋搭接时,不应因直径不同钢筋搭接而使构件截面配筋面积减小,需按较小钢筋直径计算搭接长度及接头面积百分率,见图1.8-2。
相邻纵向受力钢筋直径不同时,各自的搭接长度也不同,此时连接区段长度应按相邻搭接钢筋较大直径钢筋搭接长度的1.3倍计算,见图1.8-3。
17G101-1,P18图集中机
械连接4.不同直径钢筋机械连接时,接头面积百分率按较小直径计算。
同一构件纵向受力钢筋直径不同时,连接区段长度较大直径计算,见图1.9。
五、平法中搭接率的规定
16G101-1,P63图集中(柱)的搭接率规定16G101-1,P84图集中(梁)的搭接率规定16G101-1,P99图集中(板)的搭接率规定12G901-1,P70图集中(墙)的搭接率规定说明:关于墙的搭接率有争议,软件中有两种方式:第一种按搭接错开面积百分率计算;第二种按平法图集计算。
六、钢筋安装要求钢筋绑扎前先认真熟悉图纸,检查配料表与图纸、设计是否有出入,仔细检查成品尺寸、心头是否与下料表相符。
核对无误后方可进行绑扎。
采用20#铁丝绑扎直径12以上钢筋,22#铁丝绑扎直径10以下钢筋。
墙①墙的钢筋网绑扎同基础。
钢筋有90°弯钩时,弯钩应朝向混凝土内。
②采用双层钢筋网时,在两层钢筋之间,应设置撑铁(钩)以固定钢筋的间距。
③墙筋绑扎时应吊线控制垂直度,并严格控制主筋间距。
剪力墙上下两边三道水平处应满扎,其余可梅花点绑扎。
④为了保证钢筋位置的正确,竖向受力筋外绑一道水平筋或箍筋,并将其与竖筋点焊,以固定墙、柱筋的位置,在点焊固定时要用线锤校正。
⑤外墙浇筑后严禁开洞,所有洞口预埋件及埋管均应预留,洞边加筋详见施工图。
墙、柱内预留钢筋做防雷接地引线,应焊成通路。
其位置、数量及做法详见安装施工图,焊接工作应选派合格的焊工进行,不
得损伤结构钢筋,水电安装的预埋,土建必须配合,不能错埋和漏埋。
梁与板①纵向受力钢筋出现双层或多层排列时,两排钢筋之间应垫以直径15mm的短钢筋,如纵向钢筋直径大于25mm时,短钢筋直径规格与纵向钢筋相同规格。
②箍筋的接头应交错设置,并与两根架立筋绑扎,悬臂挑梁则箍筋接头在下,其余做法与柱相同。
梁主筋外角处与箍筋应满扎,其余可梅花点绑扎。
③板的钢筋网绑扎与基础相同,双向板钢筋交叉点应满绑。
应注意板上部的负钢筋(面加筋)要防止被踩下;特别是雨蓬、挑檐、阳台等悬臂板,要严格控制负筋位置及高度。
④板、次梁与主梁交叉处,板的钢筋在上,次梁的钢筋在中层,主梁的钢筋在下,当有圈梁或垫梁时,主梁钢筋在上。
⑤楼板钢筋的弯起点,如加工厂(场)在加工没有起弯时,设计图纸又无特殊注明的,可按以下规定弯起钢筋,板的边跨支座按跨度1/10L为弯起点。
板的中跨及连续多跨可按支座中线1/6L为弯起点。
⑥框架梁节点处钢筋穿插十分稠密时,应注意梁顶面主筋间的净间距要有留有30mm,以利灌筑混凝土之需要。
⑦钢筋的绑扎接头应符合下列规定:1)搭接长度的末端距钢筋弯折处,不得小于钢筋直径的10倍,接头不宜位于构件最大弯矩处。
2)受拉区域内,Ⅰ级钢筋绑扎接头的末端应做弯钩,Ⅱ级钢筋可不做弯钩。
3)钢筋搭接处,应在中心和两端用铁丝扎牢。
4)受拉钢筋绑扎接头的搭接长度,应符合结构设计要求。
5)
受力钢筋的混凝土保护层厚度,应符合结构设计要求。
6)板筋绑扎前须先按设计图要求间距弹线,按线绑扎,控制质量。
7)为了保证钢筋位置的正确,根据设计要求,板筋采用钢筋马凳纵横@600予以支撑。
七、补充:第一节柱、梁、墙、板混凝土保护层示意图欢迎同行发表观点,感谢转发、评论。
有不妥之处请您指正,我们共同学习进步,谢谢!。