storage-network-protocal-opt-150chn
链路聚合报错udld error detected err disable处理经验
链路聚合报错udld error detected err disable处理经验链路聚合报错udlderrordetectederr-disable处理经验链接聚合错误UdleErrorDetectedErr disable1、环境结构:Cisco4507用于聚合1,h3c5560用于聚合2。
聚合1的G4/6和G4/11分别与聚合2的T1/0/51和T1/0/52连接并聚合。
2、故障现象:(1)汇聚2设备H3C聚合T1/0/51、T1/0/52端口指示灯亮灭,每分钟来回切换一次(2)登录到汇聚1设备,检查聚合的g4/6和g4/11端口状态,两个端口down/up来回切换,一分钟左右切换一次3.失败的设备日志:*sep816:39:50.845:ì-5-unbundle:interfacegi4/11lefttheport-channelpo5*sep816:39:51.617:ì-5-bundle:interfacegi4/6 JoinedPort-channelpo5*sep816:40:20.845:%pm-4-err_recover:attemptingtorecoverfromudlderr-disablestateongi4/11*sep816:40:27.837:%udld-4-udld_uu端口_u禁用:udlddisabledinterfacegi4/6,检测到单向链接*sep816:40:27.837:%pm-4-err_disable:udlderrordetectedongi4/6,puttinggi4/6inerr-disablestate4.接口配置:汇聚设备1cisco4507,g4/6和g4/11interfacegigabitethernet4/6描述Sysc_uz1q_uuC5560_uT1/0/51 SwitchPortTrunkAllowedVLAN956994999101SwitchPortModeTrunkIPAccess-groupacl-virusinipaccess-groupacl-VirusOutspeedNoneGottateUDLDPort攻击性通道-protocollacpchannel-group5modeactiveinterfacegigabitethernet4/11描述YSC_uuz1q_uuc560_uu5;T1/0/52 SwitchPortTrunkAllowedVLAN956994999101SwitchPortModelTrunkIPAccess组ACL病毒间隔组ACL病毒超出速度协商PortaggregateTechnel协议通道组5模式聚合设备2h3c5560t1/0/51和T1/0/52interfaceten-gigabitethernet1/0/51portlink-modebridge来自cysc-txgs-4506\ge4/6portlink类型中继的描述porttrunkpermitvlan19569949991101portlink-aggregationgroup5interfaceten-gigabitethernet1/0/52portlink-modebridge来自cysc-txgs-4506\ge4/11端口链接类型中继的描述porttrunkpermitvlan19569949991101portlink-aggregationgroup54、故障分析:根据上述情况,基本确定故障原因:(1)由于聚合链路两端使用了不通厂商的设备,而cisco4507设备开启了udid(单项链路检测,cisco思科私有二层协议)功能,链路故障而导致udid将接口down掉,并不断来回切换(2)思科将errdetect扩展到STP和聚合,将在与其他制造商的互连中导致难以解释的问题5、故障定位聚合链路中两条链路的传输质量差异很大,UDID将其误认为是单链路传输,并来回切换,导致网络中断。
神州数码路由器及交换机配置命令
神州数码交换机配置命令交换机基本状态:hostname> ;用户模式hostname# ;特权模式hostname(config)# ;全局配置模式hostname(config-if)# ;接口状态交换机口令设置:switch>enable ;进入特权模式switch#config terminal ;进入全局配置模式switch(config)#hostname ;设置交换机的主机名switch(config)#enable secret xxx ;设置特权加密口令switch(config)#enable password xxa ;设置特权非密口令switch(config)#line console 0 ;进入控制台口switch(config-line)#line vty 0 4 ;进入虚拟终端switch(config-line)#login ;允许登录switch(config-line)#password xx ;设置登录口令xxswitch#exit ;返回命令交换机VLAN设置:switch#vlan database ;进入VLAN设置switch(vlan)#vlan 2 ;建VLAN 2switch(vlan)#no vlan 2 ;删vlan 2switch(config)#int f0/1 ;进入端口1switch(config-if)#switchport access vlan 2 ;当前端口加入vlan 2switch(config-if)#switchport mode trunk ;设置为干线switch(config-if)#switchport trunk allowed vlan 1,2 ;设置允许的vlan switch(config-if)#switchport trunk encap dot1q ;设置vlan 中继switch(config)#vtp domain ;设置发vtp域名switch(config)#vtp password ;设置发vtp密码switch(config)#vtp mode server ;设置发vtp模式switch(config)#vtp mode client ;设置发vtp模式交换机设置IP地址:switch(config)#interface vlan 1 ;进入vlan 1switch(config-if)#ip address ;设置IP地址switch(config)#ip default-gateway ;设置默认网关switch#dir Flash: ;查看闪存交换机显示命令:switch#write ;保存配置信息switch#show vtp ;查看vtp配置信息switch#show run ;查看当前配置信息switch#show vlan ;查看vlan配置信息switch#show interface ;查看端口信息switch#show int f0/0 ;查看指定端口信息完了最最要的一步。
ovs常用命令
ovs常用命令OVs(Open vSwitch)是一种开源的虚拟交换机,主要用于虚拟化环境中的网络管理。
在使用 OVs 进行网络管理时,我们需要掌握一些常用的命令,以便更有效地进行网络配置和管理。
以下是 OVs 常用的一些命令及其介绍:1. ovs-vsctl add-br <bridge>:创建一个新的虚拟交换机。
2. ovs-vsctl show:显示当前 OVs 系统中所有交换机、端口和连接信息。
3. ovs-vsctl add-port <bridge> <port>:向虚拟交换机添加一个新的端口。
4. ovs-vsctl del-port <bridge> <port>:从虚拟交换机中删除一个指定的端口。
5. ovs-ofctl add-flow <bridge> <flow>:添加一个新的流规则。
6. ovs-ofctl dump-flows <bridge>:显示指定交换机的流规则信息。
7. ovs-ofctl del-flows <bridge>:删除指定交换机的所有流规则。
8. ovs-ofctl mod-flows <bridge> <flow>:修改指定交换机的流规则信息。
9. ovs-ofctl add-group <bridge> <group>:添加一个新的组规则。
10. ovs-ofctl dump-groups <bridge>:显示指定交换机的组规则信息。
11. ovs-ofctl del-groups <bridge>:删除指定交换机的所有组规则。
12. ovs-ofctl mod-groups <bridge> <group>:修改指定交换机的组规则信息。
除了以上列举的常用命令外,还有一些常用的交换机管理命令,如:ovs-appctl,ovs-dpctl,ovs-ofctl,ovs-pki 等等,这些命令主要用于对交换机的配置和管理。
H3C Neocean IX3000网络存储系统教程11-快照和快照拷贝
目录第11章快照和快照拷贝 .......................................................................................................... 11-111.1 基本原理......................................................................................................................... 11-111.1.1 快照技术.............................................................................................................. 11-111.1.2 快照资源.............................................................................................................. 11-111.1.3 快照拷贝.............................................................................................................. 11-211.2 基本操作......................................................................................................................... 11-211.2.1 任务概览.............................................................................................................. 11-211.2.2 创建快照资源....................................................................................................... 11-211.2.3 查看快照资源状态 ............................................................................................. 11-1011.2.4 为快照资源添加镜像.......................................................................................... 11-1111.2.5 重新初始化快照资源.......................................................................................... 11-1111.2.6 手动扩展快照资源 ............................................................................................. 11-1111.2.7 删除快照资源..................................................................................................... 11-1211.2.8 更改快照资源的属性.......................................................................................... 11-1211.2.9 创建快照拷贝..................................................................................................... 11-1411.2.10 查看快照拷贝状态 ........................................................................................... 11-18第11章快照和快照拷贝11.1 基本原理11.1.1 快照技术利用快照技术,可用较少的存储资源记录一个数据卷在特定时间点的数据状态。
博科存储网络运维指导手册
博科存储网络运维指导手册V ERSION 1.02016年7月文档修订记录文档编号:标题博科存储网络运维指导手册摘要本文档是为博科存储网络定制的运维指导手册当前版本V1.0创建日期2016-7文档作者舒磊文件名称博科存储网络维指导手册.doc修改记录日期修改人编写者摘要目录文档修订记录.................................................................................................................................... I I 目录.................................................................................................................................................. I II 前言 (1)文档目的 (1)编写环境 (1)适用人员 (1)内容范围 (1)一、网络架构描述 (2)二、主要运维场景 (4)1.端口故障 (4)具体现象 (4)故障信息确认 (4)故障处理 (7)影响范围 (14)预计处理时间 (14)验证方案 (14)2.磁盘访问故障 (15)具体现象 (15)故障信息确认 (15)故障处理 (15)影响范围 (17)预计处理时间 (17)验证方案 (17)3.端口板故障 (18)具体现象 (18)故障信息确认 (18)故障处理 (19)影响范围 (20)预计处理时间 (20)验证方案 (21)4.引擎故障 (21)具体现象 (21)故障信息确认 (21)故障处理 (22)影响范围 (24)预计处理时间 (24)验证方案 (24)5.风扇故障 (24)故障信息确认 (24)故障处理 (26)影响范围 (26)预计处理时间 (27)验证方案 (27)6.电源故障 (27)具体现象 (27)故障信息确认 (27)故障处理 (28)影响范围 (29)预计处理时间 (29)验证方案 (29)7.CR故障处理过程及方法 (29)具体现象 (29)故障信息确认 (29)故障处理 (30)影响范围 (32)预计处理时间 (33)验证方案 (33)8.边缘交换机整机故障 (33)具体现象 (33)故障信息确认 (33)故障处理 (34)影响范围 (34)预计处理时间 (34)验证方案 (34)9.核心光纤交换机整机故障 (35)具体现象 (35)故障信息确认 (35)故障处理 (35)影响范围 (36)预计处理时间 (36)验证方案 (36)三、主要变更场景 (37)1.微码升级 (37)配置备份 (38)微码升级 (38)校验微码升级 (40)微码升级常见问题 (40)2.新设备上线 (43)3.新增ZONE配置 (62)4.修改CFG、ZONE、A LIAS的名字 (64)5.删除ZONE或Z ONE的成员 (65)7.交换机扩容 (69)补充命令介绍 (71)F RAMELOG --SHOW 指令: (71)F ABRICLOG --SHOW 指令: (72)前言文档目的此文档主要用于工行博科存储网络的日常变更操作、故障处理以及存储网络的规模扩展,帮助行内博科SAN岗维护人员快速定位修复故障、熟悉日常变更操作流程,以及提高博科SAN日常运维效率。
Aolynk-S1508LV100R004版本说明书
Aolynk S1508LV100R004版本说明书杭州华三通信技术有限公司Aolynk S1508LV100R004版本说明书关键词:Logo切换摘要:此版本系Logo切换版本缩略语:缩略语英文全名中文解释VLAN Virtual Local Area Network 虚拟局域网ServiceofQoS Quality服务质量目录1 版本信息 (4)1.1 版本号 (4)1.2 历史版本信息 (4)1.3 版本配套表 (4)2 版本使用限制及注意事项 (4)3 版本特性说明 (5)3.1 版本硬件特性 (5)3.2 版本软件特性 (5)4 版本变更说明 (5)4.1 特性变更说明 (5)4.2 命令行变更说明 (5)4.3 MIB变更说明 (5)4.4 操作方式变更说明 (5)5 存在问题与规避措施 (6)6 解决问题列表 (6)7 配套资料 (6)7.1 配套资料清单 (6)7.2 配套产品资料的获取方法 (6)8 版本升级操作指导 (6)表目录表1 历史版本信息表 (4)表2 版本配套表 (4)表3 特性变更说明 (5)表4 配套手册清单 (6)表5 从网站查询和下载资料的说明 (6)1 版本信息1.1 版本号版本号:S1508LV100R0041.2 历史版本信息表1历史版本信息表版本号基础版本号发布日期备注S1508LV100R004S1508LV100R0032007-05-16无S1508LV100R003S1508LV100R0012006-09-30无S1508LV100R001首次发布2006-04-29无1.3 版本配套表表2版本配套表系列以太网交换机产品系列 AolynkS1500型号S1508L内存需求无FLASH需求无BOOTROM版本号无目标文件名称S1508LV100R004.exeQUIDVIEW版本号无CAMS版本号无WEB版本号无备注无2 版本使用限制及注意事项无3 版本特性说明3.1 版本硬件特性无3.2 版本软件特性无4 版本变更说明4.1 特性变更说明表3特性变更说明版本号项目描述硬件特性更新无S1508LV新增特性:100R004软件特性更新显示配置:增加显示当前配置按钮。
华为MA5680T接入网设备命令整合
华为MA5680T接入网设备命令整合HUAWEI_MA5680T以下为常用命令ping 延迟----------------------------------------------------------------------------ping -c 100 -s 2000 10.70.96.132----------------------------------------------------------------------------新MAC地址添加----------------------------------------------------------------------------MA5680T#display ont autofind all /*查看OLT下自动识别ONT*/----------------------------------------------------------------------------查看单板ONT的状态----------------------------------------------------------------------------MA5680T#display board 0/1 /*查看单板ONT的状态*/----------------------------------------------------------------------------OLT添加或修改ONT的mac地址----------------------------------------------------------------------------MA5680T(config)#interface epon 0/1MA5680T(config-if-epon-0/1)#ont modify 4 12 mac 286E-D422-82AB /*在0/1/4 12里修改*/ ----------------------------------------------------------------------------看业务流端口----------------------------------------------------------------------------MA5680T#display service-port port 0/2/1 sort-by port /*看业务流端口*/----------------------------------------------------------------------------添加OLT上行端口流量----------------------------------------------------------------------------MA5680T(config)#interface giu 0/20 /*OLT上行端口流量*/MA5680T(config-if-giu-0/20)#display port traffic 0接收流量(包/秒) =5550接收流量(字节/秒) =2951772发送流量(包/秒) =4378发送流量(字节/秒) =2951400----------------------------------------------------------------------------|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||====================================================================== ===============HUAWEI_MA5616以下为常用命令MA5616#display emu环境监控单元参数----------------------------------------------------------------------------ID 类型状态| ID 类型状态----------------------------------------------------------------------------0 H831VESC 正常| 1 风扇框正常2 - - |3 - -4 - - |5 - -6 - - |7 - -8 - - | 9 - -10 - - | 11 - -12 - - | 13 - -14 - - | 15 - -----------------------------------------------------------------------------看风扇温度。
NetWorker数据备份安装配置及维护手册
EMC Networker备份系统实施配置与维护手册Networker 用户名administrator 密码abcd1234VCENTER 用户名**************************密码:!QAZ2wsx VBA用户名root密码Abcd12345目录一、备份环境描述...................................................................................................................... - 2 -1.1备份服务器BackupServer ................................................................................. - 2 -1.2备份客户端BackupClient................................................................................... - 2 -1.3备份设备规划 ....................................................................................................... - 2 -二、软件安装.............................................................................................................................. - 2 -2.1备份服务器端软件安装................................................................................................ - 3 -2.1.1Windows平台的Networker Server软件安装............................................... - 3 -2.1.2启动Networker管理控制台.......................................................................... - 10 -2.2 备份客户端软件安装................................................................................................. - 16 -2.2.1 Windows系统Networker Client软件安装 ................................................. - 16 -2.2.2 RedHat Linux Networker Client软件安装 .................................................. - 20 -2.3 NMO数据库在线备份模块的安装 ........................................................................... - 21 -2.4 NMSQL数据库在线备份模块的安装....................................................................... - 28 -三、备份设置............................................................................................................................ - 28 -3.1 备份设备创建和设置................................................................................................. - 28 -3.1.1 DataDomain VTL创建..................................................................................... - 28 -3.2 备份组的创建和设置................................................................................................. - 33 -3.3 备份客户端的创建和设置......................................................................................... - 34 -3.3.1文件系统客户端的创建.................................................................................. - 34 -3.3.2 VMware虚拟客户端的备份设置 .................................................................. - 35 -3.3.3 Oracle备份库户端的创建............................................................................. - 46 -3.3.4 MSSQLServer数据备份配置 .......................................................................... - 50 -3.4备份策略的设置.......................................................................................................... - 53 -3.4.1 备份调度时间表(Schdules)的设置............................................................ - 53 -3.4.2 Polices的创建 .................................................................................................. - 55 -3.5 Oracle数据备份的设置 .............................................................................................. - 56 -五、恢复.................................................................................................................................... - 59 -5.1 Oracle数据库的恢复 .................................................................................................. - 59 -5.1.1测试环境.......................................................................................................... - 59 -5.1.2测试过程.......................................................................................................... - 59 -5.2 Windows普通文件恢复.............................................................................................. - 64 -5.3 VMware虚拟客户机image文件恢复....................................................................... - 68 -5.4 MSSQLServer恢复..................................................................................................... - 72 -六、日常维护............................................................................................................................ - 79 -6.1定期检查备份结果是否成功...................................................................................... - 79 -6.2检查相关日志.............................................................................................................. - 79 -6.3检查磁带的使用情况.................................................................................................. - 80 -6.4定期备份备份服务器的NetWorker配置信息和Console库 ................................... - 80 -6.5寻求帮助途径.............................................................................................................. - 80 -七、注册License ...................................................................................................................... - 81 -7.1查找备份服务器的主机ID(HostID)..................................................................... - 81 -7.2注册License ................................................................................................................ - 82 -一、备份环境描述数据的备份环境如下:1.1备份服务器BackupServerOS:Windows 2008 x64NetWorker:NW8.1.1 Server1.2备份客户端BackupClient目前纳入备份考虑范围的主要有以下系统:备份客户端版本均为NW8.0.1,Oracle数据库模块为NMO5.0,MSSQL模块版本均为NMSQL5.2.21.3备份设备规划1、采用DataDomain设备做为备份设备,其中SAP、ERP、PDM、OA和NDMP实现LAN-Free备份。
harmonyos persistentstorage 使用 -回复
harmonyos persistentstorage 使用-回复标题:深入理解与使用HarmonyOS的PersistentStorageHarmonyOS,作为华为推出的全场景分布式操作系统,以其独特的设计理念和强大的功能特性,正在逐步影响并改变着全球的操作系统格局。
其中,PersistentStorage是HarmonyOS中一项重要的数据存储技术,它提供了持久化数据存储的能力,使得应用程序可以在设备重启或者应用程序关闭后仍然保留其数据。
本文将详细解析PersistentStorage的使用方法和步骤。
一、理解PersistentStoragePersistentStorage,即持久化存储,是HarmonyOS为应用程序提供的本地数据存储解决方案。
它允许应用程序在设备的内部存储空间中创建、读取、更新和删除数据,即使在设备重启或应用程序关闭后,这些数据也能得以保留。
相比于传统的文件存储方式,PersistentStorage具有以下优势:1. 简化数据管理:PersistentStorage提供了一套统一的数据访问接口,开发者无需关心底层的文件系统细节,可以更专注于业务逻辑的实现。
2. 数据安全:PersistentStorage对存储的数据进行了加密处理,增强了数据的安全性。
3. 性能优化:PersistentStorage采用了高效的存储算法和数据结构,提高了数据的读写速度。
二、初始化PersistentStorage在使用PersistentStorage之前,首先需要进行初始化操作。
以下是在HarmonyOS中初始化PersistentStorage的基本步骤:1. 创建PersistentStorage实例:通过调用PersistentStorage类的getInstance方法,可以获取PersistentStorage的单例对象。
javaPersistentStorage storage = PersistentStorage.getInstance();2. 设置数据目录:PersistentStorage默认的数据存储路径为"/data/data/<package_name>/files"。
ITN151配置模板
raisecom
ena
raisecom
config
create vlan XXX,600 active
interface line 1
switchport mode trunk
switchport trunk allowed vlan all
y
exit
interface line 2
round-trip (ms) min/avg/max = 0/12/64
返回”!”表示通,“U”表示不通。
如果PING不通网关,请查看网管VLAN是否能学习到MAC地址
如学不到地址,需联系PTN传输检查通道是否做对;
如能学到地址,需核对管理IP是否有冲突,
或更换其他IP。
Ping网关通,网管通道是OK的,
exit
interface client 3
switchport access vlan xxx
exit
interface client 4
switchport access vlan xxx
exit
ip address 172.50.1.xx 255.255.0.0 600 line 1,2
ip default-gateway 172.50.1.1
exit
wr
show running-config 查看配置结果
恢复出厂设置:
erase
y
reboot
y
show mac-address-table l2-address 查看MAC地址
show interface line 1 查看光口1状态
bgpdump 用法 -回复
bgpdump 用法-回复bgpdump 是一个用于分析和处理BGP (边界网关协议) 路由器输出的转储文件的工具。
它可以帮助网络管理员和研究者更深入地了解和分析网络中的路由信息。
本文将介绍bgpdump 的安装和使用,以及如何利用它来提取有关网络路由的有用信息。
第一步:安装bgpdump 工具bgpdump 是一个开源工具,可以从其官方网站(第二步:理解bgpdump 文件格式bgpdump 用于处理BGP 路由器的输出文件。
这些输出文件通常是二进制文件,需要使用bgpdump 工具进行分析。
bgpdump 文件格式主要有两种类型:MRT 格式和RIPE NCC 格式。
MRT 格式用于路由器输出的转储文件,而RIPE NCC 格式则是由RIPE NCC 的Route Collector 工具生成的。
第三步:转换和分析bgpdump 文件一旦安装了bgpdump 工具并熟悉了文件格式,就可以开始转换和分析bgpdump 文件了。
以下是一些常用的bgpdump 命令行选项:1. 转换MRT 文件为文本格式:bgpdump -m input.mrt > output.txt这个命令将输入文件input.mrt 转换为文本格式,并输出到output.txt 文件。
2. 过滤特定的路由信息:bgpdump -O output.txt -s 192.0.2.0/24这个命令将从input.mrt 文件中提取出子网为192.0.2.0/24 的路由信息,并将结果保存到output.txt 文件中。
3. 输出路由器更新信息:bgpdump -O output.txt -T UPDATES input.mrt这个命令将从input.mrt 文件中提取出所有的路由器更新信息,并将结果保存到output.txt 文件中。
4. 提取特定时间段的路由信息:bgpdump -O output.txt -T ROUTES -t start_time end_time input.mrt这个命令将从input.mrt 文件中提取出指定时间范围内的路由信息,并将结果保存到output.txt 文件中。
ovs 常用命令
ovs 常用命令OVS(Open vSwitch)是一种开源的虚拟交换机,常用于构建软件定义网络(SDN)和网络功能虚拟化(NFV)环境。
本文将介绍一些常用的OVS命令,帮助读者更好地理解和使用OVS。
1. ovs-vsctl:这是OVS的主要管理工具,用于配置和管理OVS的交换机和端口。
可以使用该命令来创建、删除和修改虚拟交换机、端口、流表等。
例如,创建一个名为br0的虚拟交换机可以使用以下命令:```ovs-vsctl add-br br0```2. ovs-ofctl:这是OVS的OpenFlow控制器命令行工具,用于配置和管理OpenFlow协议相关的功能。
可以使用该命令来查看和修改流表、查询交换机状态等。
例如,查看br0上的流表可以使用以下命令:```ovs-ofctl dump-flows br0```3. ovs-dpctl:这是OVS的数据路径控制器命令行工具,用于配置和管理OVS的数据路径。
可以使用该命令来查看和修改数据路径的配置信息。
例如,查看br0上的数据路径信息可以使用以下命令:```ovs-dpctl show br0```4. ovs-appctl:这是OVS的应用程序控制器命令行工具,用于控制和管理OVS的各个应用程序。
可以使用该命令来查看和修改应用程序的状态和配置信息。
例如,查看OVS的版本信息可以使用以下命令:```ovs-appctl version```5. ovs-ofctl dump-ports:这个命令用于查看虚拟交换机上的端口信息。
可以使用该命令来查看端口的状态、速率、传输统计等。
例如,查看br0上的端口信息可以使用以下命令:```ovs-ofctl dump-ports br0```6. ovs-vsctl add-port:这个命令用于向虚拟交换机添加物理端口或者虚拟端口。
可以使用该命令将物理网卡连接到虚拟交换机,或者将虚拟机的虚拟网卡连接到虚拟交换机。
神州数码路由器及交换机配置命令
神州数码路由器及交换机配置命令简介神州数码是一个中国的网络设备制造商。
它提供了多种路由器和交换机产品,包括SOHO、企业和运营商级别的产品。
在这篇文档中,我们将介绍对神州数码路由器及交换机进行配置的基本命令。
这些命令可用于启用和禁用端口、配置具有VLAN的端口以及管理路由和静态路由等。
命令列表所有设备通用命令以下是在所有神州数码路由器和交换机上都可以执行的通用命令。
1. 基本配置enable // 进入特权模式configure terminal // 进入全局配置模式hostname <name> // 配置设备名称banner motd #<message># // 设置登录提示信息interface <interface> // 进入具体端口的配置界面no shutdown // 开启端口shutdown // 关闭端口exit // 退出当前模式show running-config // 显示当前配置write memory // 将当前配置保存到FLASH文件系统中,以便重启后仍然存在2. VLAN 配置vlan <id> // 进入 VLAN 配置模式name <name> // 配置 VLAN 名称exit // 退出 VLAN 配置模式interface <interface> // 进入具体端口的配置界面switchport access vlan <id> // 配置端口所在VLAN号,使端口成为 ACCESS 端口switchport mode trunk // 配置端口为 TRUNK 端口,可同时传输多个 VLA N3. 静态路由ip route <destination_network> <destination_subnet_mask> <next_hop_a ddress> // 添加静态路由show ip route // 显示当前路由表某些设备具有的高级命令以下命令在某些神州数码路由器和交换机上可用。
nchnroutes 用法 -回复
nchnroutes 用法-回复nchnroutes是一个用于网络规划和路由管理的工具,它通过添加和配置自定义的网络路由规则来实现对网络流量的控制和管理。
本文将逐步介绍nchnroutes的基本用法和配置步骤。
第一步:安装nchnroutes要使用nchnroutes,首先需要在您的计算机上安装它。
nchnroutes可以在GitHub上找到并下载。
在下载完成后,解压压缩包,并将解压后的文件放在您喜欢的位置。
第二步:准备配置文件在开始使用nchnroutes之前,您需要准备一个配置文件,其中包含您希望设置的网络路由规则。
配置文件可以是一个纯文本文件,您可以使用文本编辑器打开并编辑它。
配置文件的格式如下:# 注释,以井号开头# 添加自定义的网络路由规则10.0.0.0/8192.168.0.0/16在配置文件中,每一行表示一条网络路由规则。
您可以使用CIDR格式(Classless Inter-Domain Routing)来指定子网的IP地址段。
第三步:生成路由表当您准备好配置文件后,可以使用nchnroutes生成路由表。
打开终端或命令提示符窗口,并导航到nchnroutes文件的位置。
输入以下命令来生成路由表:nchnroutes.py -f 路径/至/配置文件其中,-f参数指定配置文件的路径。
通过执行该命令,nchnroutes将根据配置文件中的规则,生成一张包含自定义路由规则的路由表。
第四步:应用路由表生成路由表后,您需要将其应用到您的系统中,以实现对网络流量的控制。
具体应用方法取决于您使用的操作系统。
对于Windows用户,可以使用route命令来添加和删除路由规则。
打开命令提示符窗口,并执行以下命令以添加路由规则:route add 网络地址掩码网关地址其中,网络地址掩码是您在配置文件中指定的子网地址,网关地址是您希望该子网流量经过的网关地址。
对于Linux用户,可以使用ip命令来添加和删除路由规则。
adb执行原理 -回复
adb执行原理-回复ADB(Android Debug Bridge)是一种用于与Android设备通信的命令行工具。
它提供了一个客户端-守护进程模型,允许开发者在计算机上执行命令以及在设备和计算机之间传输文件。
本文将详细回答ADB执行原理。
第一步:端口转发在执行ADB命令之前,首先需要建立计算机与设备之间的通信。
为此,ADB通过在设备上开放一个TCP端口来实现。
设备默认监听5555端口进行通信。
当ADB守护进程启动时,在设备上启动一个与客户端交互的进程,并通过5555端口监听来自计算机的命令。
然而,由于安全性方面的考虑,设备默认情况下只允许来自本地(即设备自身)的连接。
因此,在第一次建立连接时,需要通过USB来进行端口转发。
这也是为什么在第一次连接时需要先通过USB将设备与计算机连接起来的原因。
当通过USB与设备建立连接后,ADB会在计算机上启动一个端口转发服务,将计算机的端口与设备的端口进行绑定。
这样,当计算机上的ADB 客户端发送命令时,它们会被转发到设备上的相应端口。
这个过程被称为“端口转发”。
端口转发的目的是为了确保计算机与设备之间的通信能够顺畅进行,而不会受到设备默认只允许本地连接的限制。
第二步:命令传输当端口转发建立成功后,ADB客户端便可以向设备发送命令。
这些命令通过TCP/IP协议传输,并在设备上的ADB守护进程中执行。
ADB命令可以通过命令行工具或其他ADB客户端应用程序发送。
一旦命令发送到设备上,ADB守护进程会将其解析并执行相应的操作。
例如,发送“adb devices”命令将返回设备列表。
在命令传输过程中,ADB还提供了与设备交互的一些特殊命令。
例如,可以通过“adb shell”命令进入设备的shell环境,以便在设备上执行命令。
第三步:文件传输除了执行命令外,ADB还可以在设备和计算机之间传输文件。
这是通过ADB客户端发送相应的命令来实现的。
当需要将文件从计算机复制到设备时,可以使用“adb push”命令。
docker之故障问题解决方案
docker之故障问题解决⽅案1、报错如下⼀Error response from daemon: driver failed programming external connectivity on endpoint lnmp_mysql(61ce99378a4416221af9f6da52209b4473561a311f99e2ffa8b889915eafb56a): (iptables failed: iptables --wait -t nat -A DOCKER -p tcp -d 0/0 --dport 3308 -j DNAT --to-destination 172.17.0.2:3306 ! -i docker0: iptables: No chain/target/match by that name.(exit status 1))Error: failed to start containers: 005afd180cd7解决⽅案如下清空防⽕墙规则,重启docker[root@node03 web]# iptables -F[root@node03 web]# iptables -t nat -F[root@node03 web]# service iptables save[root@node03 web]# service iptables restart[root@node03 web]# systemctl restart docker注释:因为docker的规则会⾃⼰在iptables ⾥⾯⽣产,如果没有清空规则,会有诸多限制。
2、Navicat 远程连接docker容器中的mysql 报错1251 - Client does not support authentication protocol 解决办法解决⽅法如下:1、登录到mysql容器中[root@node03 web]# docker exec -it lnmp_mysql bash2、在登录mysqlroot@8e84ab34e6fe:/# mysql -uroot -p3、授权⽤户访问mysql> ALTER USER 'root'@'%' IDENTIFIED WITH mysql_native_password BY '123456';Query OK, 0 rows affected (2.29 sec)mysql> flush privileges;Query OK, 0 rows affected (0.39 sec)4、数据库可以链接了。
华为光传输配置命令行
常用命令行
配置类命令:
1、查看网元的运行状态:cfg-get-nestate;
2、查看网元的配置参数:cfg-get-nepara;
3、查看网元的板位配置:cfg-get-board;
4、查看公务板配置参数:cfg-get-ohppara;
5、查看时钟配置参数:cfg-get-stgpara;
6、查看业务配置情况:cfg-get-slot<sysnum>;
7、查询逻辑板位映射:cfg-get-logicbd<sysnum>;
告警类命令:
1、查看网元的当前告警:alm-get-curdata:板位号,事件标识;
0表示所有单板,所有事件;
2、查看网元的历史告警:alm-get-hisdata: 0, 0;
ECC类命令
1、查询ECC路由:ecc-get-route;
2、复位ECC端口:ecc-reset-dcc: 该SCC口的编号;
:ecc-reset-port: 板位号,光口号;3、ECC端口信息查询:ecc-get-bdinfo; (2500+设备)
:ecc-get-sccinfo; (155/622设备)4、查询网元IP地址:cm-get-ip;
数据库类命令
1、备份数据库命令::dbms-backup-all:fdb0/fdb1;
2、比较不同的数据库:dbms-compare-all:fdb0, drdb;
dbms-compare-all:fdb1, drdb;。
H3C NQA配置
本文中标有“请以实际情况为准”的特性描述,表示各型号对于此特性的支持情况 可能不同,本节将对此进行说明。
说明:
z H3C MSR 系列路由器对相关命令参数支持情况、缺省值及取值范围的差异内容 请参见本模块的命令手册。
z H3C MSR 系列各型号路由器均为集中式设备。
第1章 NQA 配置
1.1 NQA 简介
操作手册 系统分册 NQA
目录
ห้องสมุดไป่ตู้目录
第 1 章 NQA配置.....................................................................................................................1-1 1.1 NQA简介 .............................................................................................
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
CAM
ASPI
通用
设备类特殊指令集 (SBC) SCSI 体系结构模式 (SAM)
SBC
SSC
SES
更多…
共享指令集所有设备 (SPC)
SPC-2 / SPC-3
传输协议
FCP ATAPI SPI-x FC-xx
SBP
物理连接
1394
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
分会场 OPT-150
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
3
议程
• SCSI • 光纤通道 • iSCSI • FCIP
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
SCSI 目标设备 (Target)
9
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
发展历史
• 从Shugart Associates公司(seagate 前身) 于1979 年推出SCSI以来,SCSI一直在不断演进,ANSI于 1986年批准其成为标准,现称为SCSI-1 • SCSI-2 在1990年获得X3T9委员会批准,在1994年获 得ANSI批准 (ANSI X3.131)
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
5
小型计算机系统接口 (SCSI)
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
主机系统 始发设备 SCSI
• 在网络传输上承载与并行方式 连接相同的SCSI协议
I/O通道的 网络连接
• 传输必须不影响SCSI的有效负 载 (安全性、完整性、延迟)
• 光纤通道是一种传输通道
通道控制器 (HBA)
网络
目标设备
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
11
SCSI 总线
始发设备
内部 SCSI 终结器 SCSI 菊花链 线缆 链路端口上的 SCSI终结器
使用SCSI卡的系统
磁盘设备 目标
磁盘设备 目标
数据总线
磁盘设备 目标
主机 始发设备 控制总线
SCSI 终结器
磁盘驱动器
OPT-150 5179_05_2002_c1
磁盘驱动器
磁盘驱动器
目标
© 2002, Cisco Systems, Inc. All rights reserved.
节点
NL_Port FL_Port E_Port E_Port
节点
光纤通道交换机
NL_Port
节点
NL_Port
F_Port
N_Port
节点
F_Port
N_Port
节点
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
22
光纤通道体系结构模式
ULP
SCSI-3 ESCON SNMP 802.2 LLC
SCSI-FCP
FC 单字节指令集
FC-4
FC-SNMP
FC-LE
FC-3 (通用服务)
6
SCSI
• 概述/发展历史/标准
• 体系结构
• 指令描述块 (CDB)
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
7
I/O 通道
• 在计算机和用于存储数据的设备之间使用的传输技术 • 在计算机内部,或扩展至外部的存储设备 • 存储设备可由连接的主机或其它存储设备访问 • 例如:SCSI、光纤通道、ESCON
© 2002, Cisco Systems, Inc. All rights reserved.
26
点到点
• ‘N’端口光纤通道设备之间 的专用连接 • 所有链路带宽都分派给两个 节点之间的通信
N_Port
发送器
N_Port
接收器
接收器
发送器
• 适用于小规模存储设备的方 案,不具备共享功能
节点 A
• SCSI-3 是多个标准的集合, 每个标准定义SCSI一个非 常特殊的部分:物理接口、传输接口、指令接口、体系 结构模式、程序接口等
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
10
标准
指令接入方法 (CAM)
光纤通道 (Fibre Channel)
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
18
光纤通道 (FC)
• 概述/历史/标准 • 体系结构 • 实施拓扑结构 • 运行
• FC 帧结构(Framing)
I/O 控制器 I/O 通道
外部I/O
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
内部 I/O
8
SCSI I/O 通道
• SCSI I/O 通道为 SCSI 数据提 供半双工通道
应用
文件系统 块设备 通用SCSI 半双工 I/O通道
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
21
光纤通道(FC) 标准
• FC-PH 定义FC-0、FC-1和 FC-2 的级别 (物理上) • FC-FS 说明FC帧格式和光纤通道的基本控制特性 • FC-GS 定义多种与服务器类似的功能 • SCSI-FCP 定义使用光纤通道接口的SCSI-3 指令协议的 操作 • FC-FG 定义光纤通道交换架构的常见特性 • FC-SW 描述光纤通道交换架构的交换组件 • FC-AL 是仲裁环路拓扑结构标准
12
SCSI 体系结构模式
客户机/始发设备 SCSI 请求
应用 客户机
服务器/目标设备
SCSI 应答
逻辑 单元
传输子系统
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
13
SCSI 指令模式
• SAM定义两类协议服务:
4
存储网络的体系结构
SCSI的应用 (文件系统、数据库)
SCSI 块指令 SCSI 流指令 SCSI 指令、数据和状态 并行 SCSI 传输 FCP 以FC传输SCSI 光纤通道 FCIP TCP IP 并行SCSI 接口 光纤通道物理接口 以太网等 iSCSI 以TCP/IP传输 SCSI 其它SCSI指令
目标设备-A
目标设备-B
目标设备-C
目标设备-D
―4‖
―3‖
―2‖
―0‖
LUN-A ―0‖
LUN-B ―1‖
LUN-C ―2‖
LUN-A ―0‖
LUN-A ―0‖
LUN-B ―1‖
LUN-A ―0‖
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
20
光纤通道提供的优势
通道
• 连接业务 • 物理电路 • 可靠的硬件传输 • 高速 • 低延迟 • 短距离 • 基于硬件
网络
• 无连接 • 逻辑电路 • 不可靠的传输 • 高连接 • 更高的延迟 • 更远的距离 • 基于软件
光纤通道
• 电路和分组交换
• 可靠性传输 — 误码率(BER)<10-12 • 高数据完整性 — 错误检测 • 高数据传输速率 — 100和200MB/s • 高带宽,低延迟 — 1Gbps/2Gbps • 高连接数 — 24位地址 • 长距离 — 10公里到100公里
24
光纤通道网络
• 光纤通道的拓扑结构分为三种标准
点对点
仲裁环路
交换架构
集线器
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.
25
使用交换架构的公共环路
集线器
集线器
OPT-150 5179_05_2002_c1
执行指令/确认服务 数据传送服务
• 这反映了每次数据传送的三个主要阶段:
执行: 通过命令描述块(CDB)发送请求的指令和参 数 数据: 根据指令来传送数据 确认: 接收执行指令的确认
OPT-150 5179_05_2002_c1
© 2002, Cisco Systems, Inc. All rights reserved.