RM502524中文资料
RX424024中文资料
V REG.-Nr. A651, Z E214025Contact dataContact configuration 2 COContact setsingle contact Type of interruption micro disconnectionRated current8ARated voltage / max.switching voltage AC 240/400VAC Maximum breaking capacity AC2000VA Limiting making capacity, max 4 s, duty factor 10%15A Contact materialAgNi 90/106AC coil> 1 x 106cycles Rated frequency of operation with / without load 6 / 600 min -1Contact ratings Type Load Cycles RX48A, 250VAC, 70°C, EN61810-14x104RX48A, 250VAC, 70°C, UL508 General purpose4x104Coil dataAC coil24...230VAC AC coiltyp 0,75VAOperative range2Coil insulation system according UL1446class FCoil versions,DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance powerVDC VDC VDC Ohm mW0055 3.50.550+10%5000066 4.20.668+10%529012128.4 1.2274+10%5260242416.8 2.41095+10%5260484833.6 4.84380+10%5260606042.0 6.06845+10%52611011077.011.023010+10%526All figures are given for coil without preenergization, at ambient temperature +23°CS0271-ACoil versions,AC-coil 50HzCoil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power50Hz50Hz50Hz VAC VAC VAC Ohm VA 5242418.0 3.6350+10%0.76 61511586.317.38100+15%0.76 730230172.534.532500+15%0.74 All figures are given for coil without preenergization, at ambient temperature +23°C Insulationrmsopen contact circuit1000 V rmsadjacent contact circuits2500 V rmsClearance/creepage coil-contact circuit W8 / 8 mmadjacent contact circuits W3 / 4 mmMaterial group of insulation parts W IIIaTracking index of relay base PTI 250 VInsulation to IEC 60664-1Type of insulation coil-contact circuit reinforcedopen contact circuit functionaladjacent contact circuits basicRated insulation voltage250 VPollution degree32Rated voltage system 240V400VOvervoltage category IIIOther dataRoHS - Directive 2002/95/EC compliant as per product date code 0413 Flammability class according to UL94 V-0 1)Ambient temperature range-40...+70°COperate- / release time DC coil typ 7 / 2msBounce time DC coil, NO / NC contact typ 1 / 3msVibration resistance (function) NO / NC contact20 / 4g, 10 ... 150 HzShock resistance (destruction) 100 gCategory of protection RTII - flux proof transparent version pcbMounting distance 2,5 mm 2)Resistance to soldering heat flux-proof version270°C / 10 sRelay weight14 gPackaging unit500 pcs12) Version with transparent cover: 5 mmAccessoriesFor standard version (white cover), details seeaccessories RT PCB layout / terminal assignmentBottom view on solder pinsS0163-BJDimensionsS0272-BA *) With the recommended PCB hole sizes a grid pattern from 2.5mm to 2.54mm can be used.。
创维高压包型号代换物料编号查询表
创维彩电高压包型号代换物料编号查询表物料编号品名规格5100-050014-00CRT-高压包14"3A01/3N01/3P01/3S01(通用1104-00)5100-050014-06CRT-高压包14"通用(BSC25-5208A)5100-050025-00CRT-高压包25120V5N01/5P03/5P01/5S01(通用1205-00/1205-01)5100-051025-00CRT-高压包25"140V5N10/5N20/5T035100-051025-05CRT-高压包25"5S01(BSC25-2601S)-停产5100-051029-00CRT-高压包29"140V(代5100-051409-00)5100-051051-00CRT-高压包21"通用(BSC25-N1524)5100-051080-00CRT-高压包21"3S35(BSC25-N1548)5100-051081-00CRT-高压包21"(BSC25-N1549)5100-051100-00CRT-高压包20"3T20/4T20/3Y20/3Y015100-051100-20CRT-高压包20"3N10/3N20(110V)(JF0501)5100-051101-00CRT-高压包21"21404N01/4S02/4P02/4T0221"3T30/3T36(BSC21-2694S)(可代051101-15)-停产5100-051101-06CRT-高压包 21"3S28/3S30(BSC21-2088S)5100-051101-11CRT-高压包21"3P30(JF0501-19530(051101-20/051101-24/051101-04可代)5100-051101-13CRT-高压包21"3P30(BSC24-3353H-13)5100-051101-15CRT-高压包21"3T36(BSC25-NO832)5100-051101-18CRT-高压包21"通用(BSC25-N0824)5100-051101-20CRT-高压21"3P60(通用于051101-26/BSC24-3353H-9)(CF0801-5521)5100-051101-24CRT-高压包21"(BSC24-3353H-26)5100-051101-27CRT-高压包21"(BSC25-0219Y)5100-051104-02CRT-高压包21N16AA-3Y39(BSC25-0223Z)5100-051120-00CRT-高压包 20"110V3P10/3P20/4P105100-051141-00CRT-高压包(不带泄放电阻)21T81AA/3T60(BSC24-3353H-114T)5100-051141-01CRT-高压包(BSC24-3353H-48)5100-051151-01CRT-高压包21"(通用于051201-01)(BSC25-0206R)5100-051201-01CRT-高压包21"3D21/3d20通用(BSC25-0206R)5100-051209-00CRT-高压包29"旧(BSC25-3388A)(通用于051209-03)-停产5100-051209-03CRT-高压包29"5Y21/5Y30(JF0101-01166)-停产5100-051209-16CRT-高压包29"6D95(通用于051209-18)(BSC29-0104X)5100-051209-18CRT-高压包29"6D95/6D96单聚焦(BSC29-0183X)-停产5100-051209-22CRT-高压包6P60/25T91HN(BSC29-3807-32)5100-051228-01CRT-高压包28"通用(BSC29-0119W)-停产29"5T10/5T20/5T25/5T21/5T26/5T28(代051229-03)(JF0501-2138) 5100-051229-03CRT-高压包29"5T25单聚焦(JE0501-21101)-停产5100-051229-05CRT-高压包29"5T25/5T21/5T20/5T25(BSC25-3355-17)5100-051232-00CRT-高压包32"6M31(BSC29-0109Y)-停产5100-051234-00CRT-高压包34"6D95/6D96双聚焦(BSC29-0187R)(051209-16/051209-1通用)5100-051239-00CRT-高压包29"(BSC29-0127X)5100-051255-00CRT-高压包25"4P36(BSC25-3355-53)5100-051259-00CRT-高压包29"(BSC29-0127Y)-停产5100-051301-00CRT-高压包 21"3Y20(JF0501-19179)5100-051305-00CRT-高压包25"5S28/5S30(BSC21-2067S)–停产物料5100-051305-01CRT-高压包25"4T30(BSC27-0169B)5100-051305-06CRT-高压包25"通用(BSC25-N0835)5100-051305-08CRT-高压包25"通用(BSC29-3807-9)5100-051305-12CRT-高压包25N15AA/4T60(BSC25-3355-60)5100-051309-07CRT-高压包29"5D70双聚焦(BSC29-0138G)5100-051309-08CRT-高压包29"130V5Y30/5Y21/5Y31(BSC29-0195D)5100-051309-11CRT-高压包29"5D90(BSC-29-0163C)5100-051309-12CRT-高压包29"通用(JF0101-2736A)5100-051309-13CRT-高压包29"5T30(BSC29-0199E)5100-051309-14CRT-高压包29"5T30(BSC29-0199G)(051309-13/051309-17通用)5100-051309-22CRT-高压包29"5Y30(BSC29-0156D)(051209-03/051309-08通用)5100-051309-27CRT-高压包29"(BSC25-3355-44)5100-051309-32CRT-高压包29"通用(BSC29-0188S)5100-051309-33CRT-高压包29"6M31/6M35(BSC29-0188Y)5100-051309-44CRT-高压包29"(BSC29-0107R)(051309-32/051309-33通用)5100-051334-00CRT-高压包34"5T30(通用1334-02)(JF0101-27303)-淘汰5100-051334-02CRT-高压包34"5T30(通用1334-00)(JF0101-27303D)5100-051355-00CRT-高压包25"BSC27-0107Z5100-051359-05CRT-高压包29"(BSC29-0126W)5100-051402-01CRT-高压包32"/6P20/(BSC29-3807-52)5100-051403-00CRT-高压包 34"140V5P01/5M10/5N20/5P035100-051405-00CRT-高压包25"141V5P10/5P20/5P21(JF0501-2111)5100-051405-03CRT-高压包25"4P30(BSC25-3355-27)5100-051405-04CRT-高压包25"140V5Y21(BSC27-0121C5100-051405-07CRT-高压包25"5S28(JF0501-3522)5100-051405-12CRT-高压包25"通用(BSC27-0122Z)5100-051409-00CRT-高压包 140V29旧(051209-00通用)5100-051409-01CRT-高压包29"5D20/5D26(JF2801-2802A)-停产5100-051409-02CRT-高压包29"140V5P10/5P20/5P21(JF0501-2112)(051405-00通用)5100-051409-05CRT-高压包29"5S01/5S10(BSC25-2606S)-停产5100-051409-11CRT-高压包29"5D60(BSC27-0501Q)5100-051409-15CRT-高压包29"5D60/5D66(BSC29-0162E)–停产物料5100-051409-16CRT-高压包29"(6174Z-6005T)5100-051409-28CRT-高压包29"5N10/5N20(JF0101-2708)5100-051409-30CRT-高压包29"5Y30(JF0101-2709)5100-051409-32CRT-高压包29"5P10/5P20(JF0101-2713)5100-051409-35CRT-高压包29"5M10/5M18(JF29-03R)-停产5100-051409-36CRT-高压包29"5P30单聚集(BSC29-0154C)5100-051409-40CRT-高压包29"140V5I01(JF2801-2811)-停产5100-051409-45CRT-高压包29"5I01(JF2801-2811A)5100-051409-46CRT-高压包29"5P30(JF0101-2729)(051409-36通用)-停产5100-051409-50CRT-高压包29"5I30(BSC29-0104A)5100-051409-51CRT-高压包29"5T36(BSC25-N0838)5100-051409-52CRT-高压包29"6T18(BSC29-0156W)–停产物料5100-051409-54CRT-高压包29"(BSC29-0119R)5100-051409-55CRT-高压包29"(BSC29-3935M)5100-051409-56CRT-高压包29"6P18/29T92ht(BSC29-3807-35)5100-051409-61CRT-高压包29D98HT/6D85(BSC29-0131T)(051459-01通用)5100-051425-00CRT-高压包25"通用(BSC27-0123S)-停产5100-051429-11CRT-高压包29"5D20/5D26(通用1429-10)(BSC29-0172B)5100-051429-13CRT-高压包29"5D76(BSC29-0104C)5100-051429-15CRT-高压包29"5D01单聚焦(BSC29-0102C)5100-051429-18CRT-高压包29"6D72(BSC29-0141Z)5100-051429-24CRT-高压包29"6P30(BSC29-3807-22)5100-051431-00CRT-高压包31"通用(BSC29-0107W)–停产物料5100-051432-01CRT-高压包32"(BSC29-3807-17)5100-051432-02CRT-高压包32"6T19(BSC29-0115Q)5100-051434-00CRT-高压包34"5D01/5D10(JF2801-2806)-停产5100-051434-04CRT-高压包34"140V5M10(BSC30-5540)–停产物料5100-051434-13CRT-高压包34"5P10/5P21/5P20(BSC25-2603S)-停产物料5100-051434-18CRT-高压包34"5P21双聚焦(JF0101-2725)-停产5100-051434-26CRT-高压包34"5P30(BSC29-0170C)(行变后通用051434-34)5100-051434-31CRT-高压包34"5D20/5D25(051434-20/1434-25/1434-27/1434-29/051434-37通用)BSC29-0187E)5100-051434-34CRT-高压包34SP/5P30(BSC29-0172E)-停产5100-051434-40CRT-高压包34TPHD/6M20(BSC29-0184T)5100-051438-01CRT-高压包38"140V5N10/5P01/5P03/5S01(BSC29-0194S)5100-051452-00CRT-高压包BSC29-0120Z(实际是三和厂家5132-051452-005100-051454-03CRT-高压包34"5D20/5D26(JF2801-2802E)5100-051455-05CRT-高压包25"6D91/6D92(BSC27-0122W)5100-051459-00CRT-高压包 25"/29"140V 5T02/5T105100-051459-01CRT-高压包29"6D50(BSC28-N2371)(051459-02通用)5100-051459-04CRT-高压包29"(BSC29-0135X)5100-051502-00CRT-高压包32D98HP/6D66(051402-00通用)5131-051402-00CRT-高压包32"(BSC30)5131-051452-00CRT-高压包29D18HT/6D66(银洋厂家生产,实物编号5100-051452-00)机芯行包型号高频头公司编号/基本电性能描述4A01/02/ 5101-051101-00 5200-380653-005A01(25寸)5101-051405-015A01(29寸)5100-051029-005K01 5101-051409-015D01(29寸)5100-051406-01 5200-380WO5-005D01(34寸)5100-051434-005D01(38寸)5100-051429-005D20(25/ 5100-051429-11 5200-380W18-0026/29寸)5100-051429-105D20(34寸)5100-051434-205D25(34寸)5100-051434-275100-051434-315D26(34寸)5100-051454-035D28 510-051309-16 5200-380W18-105D60 PHILPS 5100-051409-06 5200-380W10-005D60 LG 5100-051409-155D66 5100-051409-15 5200-380W08-005D70 5100-051309-07 5200-380W23-005D90 5100-051309-116D72 5100-051209-136D72 5100-051429-186D72 5100-051434-00 5200-380W20-006D72 5100-051434-395D75 5100-051309-055D76 5100-051429-135D76 5100-051309-206D91 5109-051309-33 5200-380W19-11 6D92 5100-051309-326D92 5100-051434-416D92 5100-051455-056D95 5100-051309-296D96 5100-051209-186D96 5100-051234-006D96 5109-051209-163I30 5100-051101-093P10 5100-051120-003P20 5100-051120-003P21 5100-051120-003P30 5100-051101-113P30 5100-051101-043P30 5100-051101-134P01 5101-051101-004P02 5100-051101-004P30 5100-051101-064P30 5109-051405-034P36 5100-051309-275P30(29寸)5100-051409-465P30(34寸)5100-051434-265P30 5100-051409-365P30 5100-051434-343Y20(21寸)5100-051100-003Y20(14寸)5100-050014-003Y01(14寸)5100-050014-003Y01(21寸)5100-051100-005I30 5100-051409-505M18 5100-051409-355M10 5100-051409-355N10(25寸)5100-051025-005N10(29寸)5100-051409-285N10(34寸)5100-051403-005N10(38寸)5100-051438-005N20(25寸)5100-051025-005N20(29寸)5100-051029-005N20(34寸)5100-051403-005N20(38寸)5100-051038-005N28(29寸)5100-051029-005N28(34寸)5100-051403-004N10 5100-051101-004N01 5100-051101-00 5200-380W11-00 3N01(14“)5100-050014-003N01(21”)5100-051101-003N20 5100-051100-203N10(14寸)5100-050014-003N10(21寸)5100-051100-204N02 5100-051101-004N03 5100-051101-005N01(25”)5100-050025-005N01(29“)5100-051029-005N01(34”)5100-051034-005S10 5100-051409-055Y01 5100-051025-005Y30(25寸)5100-051405-045Y30(29寸)5100-051405-045Y21(25寸)5100-051405-045Y21(29寸)5100-051209-034Y01 5100-051101-005M01(29寸)5100-051409-305M01(34寸)5100-051434-085M20 5100-051850-015M21 5100-051850-016M20 5100-051850-016M21 5100-051850-013I01 5100-050901-01 5200-380W07-005I01(29“)5100-051409-455I01(34”)5100-051434-155P01(25“)5100-050025-005P01(29”)5100-050029-005P01(34“)5100-051403-005P01(38”)5100-051438-003P01(14”)5100-050014-003P01(20“)5101-051100-003P10(14”)5100-050501-003P10(21“)5100-051120-004P10 5100-051101-005P03(25”)5100-050025-005P03(29“)5100-051029-005P03(34”)5100-051403-005P03(38“)5100-051438-005P10(25“)5100-051405-005P10(29”)5100-051409-025P10(34“)5100-051434-135P20(25”)5100-051405-005P20(29“)5100-051409-025P20(34”)5100-051434-135P21(25“)5100-051405-005P21(29”)5100-051409-025P21(34“)5100-051434-135P36 5100-51409-38 5200-380W29-01 5P21(29“)5100-051409-025P21(34”)5100-051434-135P30 (29”) 5109-051309-274S01 5101-051101-004S02 5100-051101-004S10 5101-051100-003S30 5100-051101-063S28 5100-051101-065S01(25“)5100-051025-05 5S01(29”)5100-051409-035S01(34“)5100-051434-035S01(38”)5100-051438-003S30 5100-051100-063S01(14”)5100-050014-003S01(14“)5101-051100-003S02 5100-050014-005S01(25”)5100-051405-005S28(25”)5100-051305-00 5200-380W25-00/D/KWORLD5S28(29“)5100-051209-045S30 5100-051305-003T20(14寸)5100-050014-003T20(21寸)5101-051100-003T21 5101-051100-003T30 5100-051101-053T36 5100-051101-154T01 5100-051101-004T30 5100-051405-104T36 5100-051409-514T36 5100-051305-065T03(25“)5100-051025-005T03(29”)5100-051029-005T02 5100-051459-005T10(25寸)5100-051459-005T10(29寸)5100-051029-005T21(29寸)5100-051229-005T20 5100-051229-005T25(25寸)5100-051229-005T25(29寸)5100-051229-055T25(34寸)5100-051134-005T26 5100-051229-005T28(295T30(25”)5100-051405-10 5200-380W24-005T30(29“)5100-051309-135T30(34”)5100-051434-385T32 5100-051309-145T30 5100-051334-005T36 LG 5100-051309-175T36 三星 5100-051334-02。
Schneider SW 2524-4024-4048 集成指南说明书
Schneider SW 2524-4024-4048, KiloVault Integration GuideIntroduction3 Notes on the SW31800 & 3600 HLX/CHLX4 Basic Settings4 Advanced Settings4HAB 7.5kWh6 Basic Settings6 Advanced Settings6 2100 PLC7 Basic Settings7 Advanced Settings7Resources8 SCP SW Menu Map8 InsightCloud SW Menus9 Links11IntroductionThis guide covers the recommended set-up and configuration of the Schneider Electric Conext SW Solar Hybrid Inverter System (120/240V) using the Conext System Control Panel and InsightCloud. We’ll only be covering battery related settings. In case you are using the Schneider Conext Gateway or InsightHome/Facility, these same settings are available there as well.You can download the SW Owners’ guide here:https:///SwUsersGuideIn that guide, document number 975-0638-01-01 Rev H, you can find an SCP menu map for both Basic and Advanced Settings. A menu map is also reproduced in the Resources section of this document.CAUTION:If you update the firmware on your Schneider Electric equipment, ALL the settings must be reverified. The programmed settings shown in the following tables must be applied based on desired Warranty/Cycle life. We recommend an 80% depth of discharge for our Lithium Iron Phosphate (LiFePO4 or LFP) batteries and a 50% depth of discharge for our PLC battery.Notes on the SW●As of this writing the SW 4048’s minimum high battery voltage disconnect (Hi Batt Cut Out) is 58V,slightly higher than the high voltage disconnect we recommend for 48V systems.●As of this writing, the Schneider Conext Gateway,InsightHome/Facility and InsightCloudapplication provide easier and greater control over the SW than is available through the ConextSystem Control Panel (SCP) or the Conext Combox. The Combox is being discontinued and there are no firmware updates planned for it and the SCP.The SCP provides minimal control over your system.●The maximum battery capacity for the SW is 1000Ah.●When using the SCP, the SW Advanced Settings are accessed by…○Selecting the SW on the Select Device menu○Press and release the Enter and Up Arrow and Down Arrow simultaneously. It may takea few tries to do this.○After performing this keypress,Advanced Settings appears at the top of the XW Pro Setup menu.○If you press and release Enter & Up Arrow & Down Arrow simultaneously again then Basic Settings will appear at the bottom of the Setup Menu●Put the SW into Standby Mode before changing any basic or advanced settings.○Critical loads will lose power and disconnect from the grid or generator when the SW is put into standby mode. To avoid this, place your system into Bypass before putting the SW intoStandby mode.●Put the SW into Operating Mode after changing the settings to save the changes.○If you put your system into Bypass, please remember to take it out of Bypass.1800 & 3600 HLX/CHLX Basic SettingsSetting Name1800 Setting3600 Setting24V48V24V48VBattery Type This will be overridden in Advanced SettingsBattery Capacity150Ah per Parallel String300Ah per Parallel StringMax Charge Rate Set to a percentageof 90A (the 4024max) so that whenadded to the solarcharge controlleramps, the sum is100A (per HLX inparallel)Set to a percentageof 45A (the 4048max) so that whenadded to the solarcharge controlleramps, the sum is100A (per HLX inparallel)Set to a percentageof 90A (the 4024max) so that whenadded to the solarcharge controlleramps, the sum is100A (per HLX inparallel)Set to a percentageof 45A (the 4048max) so that whenadded to the solarcharge controlleramps, the sum is100A (per HLX inparallel)Charge Cycle 2 Stage No FloatRecharge Volts (80% DoD)25.5V51V25.5V51V Low Battery Cutout24V48V24V48VAdvanced SettingsSetting Name1800 Setting3600 Setting24V48V24V48VInverter/Low Batt Cut Out24V48.0V24V48V Inverter/LBCO Delay 5 secondsInverter/LBCO Hysteresis0.5VInverter/High Batt Cut Out28.8V57.6V28.8V57.6V Charger/Batt Capacity150Ah per battery in parallel300Ah per battery in parallelCharger/Max Chg Rate Set to a percentageof 90A (the 4024max) so that whenadded to the solarcharge controlleramps, the sum is100A (per parallelstring)Set to a percentageof 45A (the 4048max) so that whenadded to the solarcharge controlleramps, the sum is100A (per parallelstring)Set to a percentageof 90A (the 4024max) so that whenadded to the solarcharge controlleramps, the sum is100A (per parallelstring)Set to a percentageof 45A (the 4048max) so that whenadded to the solarcharge controlleramps, the sum is100A(per parallelstring)Charger/Charge Cycle2-StageCharger/Default Batt Temp Warm (the default)Charger/Recharge Volts (80%DoD)25.5V51.0V25.5V51.0V Charger/Absorb Time 2 minutes or lessCharger/Batt Type CustomCharger/Custom/Eqlz Support DisabledCharger/Custom/Eqlz Voltage N/ACharger/Custom/Bulk Voltage28.2V56.4V28.2V56.4V Charger/Custom/Bulk Termination27.8V (.4V below Bulk)55.6V (.8V below Bulk)27.8V55.6V Charger/Custom/Absorb Voltage28.2V56.4V28.2V56.4V Charger/Custom/Float Voltage N/ACharger/Custom/Batt Temp Comp0 mV/°CHAB 7.5kWhPlease note: the KiloVault HAB 7.5kWh battery can only be used in 48V systems, so all settings are for the Conext 4048.Basic SettingsSetting Name Setting ValueBattery Type AGM (This will be overridden in Advanced Settings)Battery Capacity150Ah per HAB in parallelMaximum Charge Rate Set to a percentage of 45A (the 4048 max) so that when added to the solar charge controller amperage, the sum is 120A (per HAB in parallel)Charge Cycle2-StageRecharge Volts51.4VLow Battery Cut Out48.2VAdvanced SettingsSetting Name Setting Value Inverter/Low Batt Cut Out48VInverter/LBCO Delay 3 secondsInverter/LBCO Hysteresis2VInverter/High Batt Cut Out57VCharger/Battery Type CustomCharger/Batt Capacity150Ah per HAB in parallelCharger/Max Charge Rate Set to a percentage of 45A (the 4048 max) so that when added to the solar charge controller amperage, the sum is120A (per HAB in parallel)Charger/Charge Cycle 2 Stage No FloatCharger/Default Batt Temp WarmCharger/Recharge Volts for 80% DoD51.4VCharger/Absorb Time 2 minutes or lessCharger/Custom/Eqlz Support DisabledCharger/Custom/Eqlz Voltage N/ACharger/Custom/Bulk Voltage56.2VCharger/Custom/Bulk Termination Voltage55.4V (required to be at least 0.8V below Bulk) Charger/Custom/Absorb Voltage56.2VCharger/Custom/Float Voltage N/ACharger/Custom/Batt Temp Comp0 mV / °C2100 PLCBasic SettingsSetting Name24V48V Battery Type AGM (will be overridden in Advanced Settings) Battery Capacity180Ah per 2100 PLC in ParallelMax Charge Rate Set to a percentage of 90A (the 4024max) so that when added to the solarcharge controller amperage, the sum is100A (per PLC in parallel)Set to a percentage of 45A (the 4048 max) so that when added to the solar charge controller amperage, the sum is 100A (per PLC in parallel)Charge Cycle 3 Stage without a solar charge controller2 stage with a solar charge controllerRecharge Volts for 50% DoD24.6V49.2V Low Battery Cutout24V48VAdvanced SettingsSetting Name24V48V Inverter/Low Batt Cut Out24V48.0VInverter/LBCO Delay10 secondsInverter/LBCO Hysteresis2VInverter/High Batt Cut Out30V60VCharger/Batt Type CustomCharger/Batt Capacity180Ah per 2100 PLC in ParallelCharger/Max Chg Rate Set to a percentage of 90A (the 4024max) so that when added to the solarcharge controller amperage, the sum is100A (per PLC in parallel)Set to a percentage of 45A (the 4048max) so that when added to the solarcharge controller amperage, the sum is100A (per PLC in parallel)Charger/Charge Cycle 3 Stage without a solar charge controller 2 stage with a solar charge controllerCharger/Default Batt Temp Warm (the default)Charger/Recharge Volts (for 50% DoD)24.6V49.2VCharger/Absorb Time8 HoursCharger/Custom/Eqlz Support EnabledCharger/Custom/Eqlz Voltage28.4V (14.2V * 2)56.4V (14.1V * 4)Charger/Custom/Bulk Voltage28.4V (14.2V * 2)56.4V (14.1V * 4)Charger/Custom/Bulk Termination Voltage28V (required to be at least .4V below Bulk)55.6V (required to be at least .8V below Bulk) Charger/Custom/Absorb Voltage28.4V (14.2V * 2)56.4V (14.1V * 4)Charger/Custom/Float Voltage27.2V (13.6V*2)54.4V (13.6V * 4)Charger/Custom/Batt Temp Comp-3mV /°CResourcesSCP SW Menu MapInsightCloud SW MenusThese screenshots are from demonstration sites using random data on InsightCloud -https://To see this data for yourself and to practice using InsightCloud, point your web browser tohttps://, create an account,and create a new site using;●URN: urn:dev:opm:000054-Combox-587AC6N1CSWCL1●SERIAL NUMBER: SESA405035This Schneider demo site simulates a SW installation with a Schneider Conext MPPT 60 charge controller, a Conext battery monitor and a Conext Automatic Generator Start.Input any site name you wish, any date you want for the commissioning date and estimate the site, battery bank and inverter sizes using your preferred method. For this example, it was named Schneider Insight 2 Demo Site 1.From the InsightCloud home page click the demo site you set up above.On the Site Overview page, click “Configuration” to select the demo site you set up earlier.In the Device List, Click “Inverter Charger” to reveal the SW inverter. Click on one of them to load the settings control panel. To see all of the settings categories, click the “Collapse all” button. The settings mentioned above are all available here.LinksSW Installation Guide:●https:///SwInstallationGuideSW Owner’s Guide:●https:///SwOwnersGuideKiloVault HLX/CHLX Manual:●https:///static/datafiles/Others/KiloVault_HLX_Series_Manual_V2.1.2_April022021.pdf KiloVault HAB Manual:●https:///static/datafiles/Others/KLV%20HAB%20Installation%20and%20User%20Manual%20Rev%202.06.pdfKiloVault PLC Manual:●https:///static/datafiles/Others/KiloVault%202100%20PLC%20Installation%20and%20User%20Manual%20Rev%201.04.pdfRevised: 2021-05。
RM10C混合记录仪规格说明书
RM10C HYBRIDRECORDER OUTLINERM10C is 100mm calibrated hybrid recorder in a 144x144DIN front panel and short depth of 150mm case housing.The recorder has versatility of universal input and scale inwide ranges and flexibility of user-reconfigurable uniquefunctions. RM10C offers 1, 2 continuous pen and 6 dotpoint models.FEA TURESShort case depth size of 150mmIP65: Dust-proof, Water-proofWide LED with 18mm heights displayAllows user-selected consumablesRS-232C communication interface instandard specificationsUL, C-UL, CE approvedWeights only 1.5kg (Multipoint type)Optional portable housing case availableSPECIFICA TIONSz Input signalDC voltage:± 10, 0 ~ 20, 0 ~ 50, ± 200 mV DC, ± 1, 0 ~ 5,± 10 V DCThermocouple:B, R, S, K, E, J, T, C, Au-Fe, N, PR40-20, PLII, U, L Resistance temperature detector: Pt100, JPt100DC current: 4 ~ 20mA DC(with external shunt resistor: 250Ω<Charged: HMSU3081A11>) z PerformanceAccuracy: See RANGE TABLEDead band: Within 0.2% (Pen Model only)Input impedance:10MΩ min. in mV, TC input;200kΩ min. in mV, TC input (with burnout protection);1MΩ min. in Voltage input;250Ω (External shunt resister) in mA inputAllowable signal source resistance:10kΩ max. in mV, TC input;100Ω max. in mV, TC input (with burnout protection);1kΩ max. in Voltage input;10Ω max. per line in RTD inputNormal mode reduction ratio: 60dB min. (50/60 ± 0.1Hz) Common mode reduction ratio: 140dB min. (50/60 ± 0.1Hz) Isolation resistance: 0.5kV DC 20MΩ min. between theeach terminal and grounding terminal Dielectric strength:1.5kV AC for 1 minute between power terminal andgrounding terminal;0.5kV AC for 1 minute between input terminal andgrounding terminal;0.2kV AC for 1 minute between the input terminalsInter channel maximum noise voltage:200 V AC at 50/60 HzVibration resistance: 10 ~ 60Hz 1m/s2 max.Shock resistance: 2m/s2 max.Clock precision: ± 50ppm max.Chart feed accuracy: ± 0.1% max.z StructureMounting: Panel mountAllowable backward inclination: Within 30°Material (Color):Case, Polycarbonate (Black), Glass 10% UL94-V2;Door, Polycarbonate, UL94-V2 (Clear)Dust-proof, Water-proof(Complies with the IEC529-IP65) z Power Supply V oltagePower voltage (rated): 100 ~ 240V AC Power voltage: 85 ~ 264V ACFrequency (rated): 50/60HzFrequency: 45 ~ 65Hzz Normal Operating ConditionsAmbient temperature: 0 ~ 50°C Ambient humidity: 20 ~ 80%RH Supply voltage: 85 ~ 264V ACz Alarm (Relay output is optional)Alarm types: 2 types(H,L),4 levels/channelAlarm output: 250 V AC, 3 A max. (resistance load) 125 V DC, 0.5 A max.(resistance load) 30 V DC, 3 A max.(resistance load) Hysteresis width: 0.5 ± 0.2 % Setting accuracy: ± 0.5 % Outputs:Pen Model, 3 point (Built-in option, normally open); Multipoint Model, 6 point (Built-in option, normally open)z Safety Standard and EMI Standard Electrical safety:IEC1010-1,UL3101-1 installation category II and pollution degree 2. UL3101-1Emissions: EN55011 Group1 Class A Immunity: EN50082-2z Communication Interface RS-232C (Standard): 1200, 2400, 4800, 9600 RS-485 (Option): 1200, 2400, 4800, 9600z DI functionFunction Description Chart Feed Start/Stop Close: Starts Open: Stops Change Chart Speed Close: Chart speed 1 Open: Chart speed 2 Comment Print Prints programmed characters(Multipoint model is up to 16characters per line. Pen model is up to 12 characters per line.)Manual Print Close: Start to print Date and Time Print Close: Start to printUp to 3 functions among above can be selected in one recorder.z OptionChart sensor: Detects paper-out to output an alarm.INDIVIDUAL SPECIFICA TIONSBlock Item Pen Model Multi point Model Measuring Point 1, 2 6 Input Sampling 125ms 10s/6chInput Unit Display Interval 2.5s 2.5sRecording Form Disposable felt penPrinting Form Wire dot (one color ink ribbon) Wire dot with 6-color ink ribbonRecording Width 100 mmStep Response 1.0s max. to 95% of step-wise input - Dot Print Interval - 10s/ch (Note 2) Chart Paper Length : 16m, Width : 114 mm Folding width : 40 mm (Note3) Chart Speed 5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 90, 100,120, 150, 160, 180, 200, 240, 300, 360, 375, 450, 600, 720, 750, 900, 1200, 1500, 1800, 2400, 3000, 3600, 4500, 4800, 5400, 6000, 7200, 9000, 10800, 12000 mm/h0, 1, 2, 3, 4, 5, 10, 15, 20, 25, 30, 40, 50, 60,75, 80, 90, 100,120, 150, 160, 180, 200, 240, 300, 360, 375, 450, 600, 720, 750, 900, 1200, 150 mm/h (Analog recording is notdone during the chart speed setting 0 mm/h.)Recording Color (Note1) 1 pen (Red), 2 pen (Green)No.1 (Purple), No.2 (Red), No.3 (Green),No.4 (Blue), No.5 (Brown), No.6 (Black) Record & Printer Printing Color Purple Purple, Red, Green, Blue, Brown, Black Weight 1 pen: 2.0kg max., 2 pen: 2.5kg max, 1.5kg max. Power Consumption 30V A max. (at 100V AC) 25V A max. (at 100V AC)(Note 1) User-changeable arbitrary colors with set-up configuration. (Note 2) User-selective interval from 10, 20, 30 and 60 seconds. (Note 3) Clean Chart Paper: Length 12 mMEASUREMENT RANGEThe junction compensation accuracy is not calculated into digital readout accuracy and recording accuracy . The junction compensation accuracy is based on operating conditions: T emperature, 23 ± 2°C; Humidity , 55 ± 10%RH; Power source 85 ~ 264V AC; Frequency , 50/60Hz ± 1%; Warm-up time 30 minutes min.; No effect of vibration and shock of over recorder’s resistibility .Junction compensation accuracy: B, R, S, Au-Fe, PR40-20 ± 1°CK, E, J, T , C, N, PLII, U, L ± 0.5°CMeasurementDigital AnalogType RangeMeasurementrangeAccuracy Max.ResolutionAccuracy- 10.00 ~ 10.00mV ±(0.2% of rdg + 3digits) 10µV0.00 ~ 20.00mV ±(0.2% of rdg + 3digits) 10µV 0.00 ~ 50.00mV ±(0.2% of rdg + 2digits) 10µV - 200.0 ~ 200.0mV ±(0.2% of rdg + 3digits) 100µV - 1.000 ~ 1.000V ±(0.1% of rdg + 3digits) 1mV0.000 ~ 5.000V±(0.2% of rdg + 2digits)1mV - 10.00 ~ 10.00V ±(0.3% of rdg + 3digits) 10mV DC Voltage/ Current Input4 ~ 20mA ±(0.2% of rdg + 2digits) 0.01mADigital accuracy ±(0.3% of span)B 0.0 ~ 1820.0°C ±(0.15% of rdg + 1°C) (Note 1) R1 0.0 ~ 1760.0°C ±(0.15% of rdg + 1°C) (Note 2) R2 0.0 ~ 1200.0°C ±(0.15% of rdg + 0.8°C) (Note 2) S 0.0 ~ 1760.0°C ±(0.15% of rdg + 1°C) (Note 2) K1 - 200.0 ~ 1370.0°C ±(0.15% of rdg + 0.7°C) (Note 3) K2 - 200.0 ~ 600.0°C ±(0.15% of rdg + 0.4°C) (Note 3) K3 - 200.0 ~ 300.0°C ±(0.15% of rdg + 0.3°C) (Note 3) E1 - 200.0 ~ 800.0°C ±(0.15% of rdg + 0.5°C) E2 - 200.0 ~ 300.0°C ±(0.15% of rdg + 0.4°C) E3 - 200.0 ~ 150.0°C ±(0.15% of rdg + 0.3°C)J1 - 200.0~ 1100.0°C ±(0.15% of rdg + 0.5°C) (Note 4) J2 - 200.0 ~ 400.0°C ±(0.15% of rdg + 0.4°C) (Note 4)J3 - 200.0 ~ 200.0°C ±(0.15% of rdg + 0.3°C) (Note 4) T1 - 200.0 ~ 400.0°C ±(0.15% of rdg + 0.5°C) (Note 4) T2 - 200.0 ~ 200.0°C ±(0.15% of rdg + 0.4°C) (Note 4) C 0.0 ~ 2320.0°C ±(0.15% of rdg + 1°C) 0.1°CAu-Fe 1 .0 ~ 300.0K ±(0.15% of rdg + 1K) (Note 5) 0.1KN 0.0 ~ 1300.0°C ±(0.15% of rdg + 0.7°C) PR40-20 0.0 ~ 1880.0°C ±(0.15% of rdg + 1°C (Note 6) PLII 0.0 ~ 1390.0°C ±(0.15% of rdg + 0.7°C) U - 200.0 ~ 400.0°C ±(0.15% of rdg + 0.5°C) (Note 7) Thermo- couple L - 200.0 ~ 900.0°C ±(0.15% of rdg + 0.5°C) (Note 7) 0.1°CDigital accuracy ±(0.3% of span)Pt100-1 - 200.0 ~ 650.0°C ±(0.15% of rdg + 0.3°C)Pt100-2 - 200.0 ~ 200.0°C ±(0.15% of rdg + 0.2°C)JPt100-1 - 200.0 ~ 630.0°C ±(0.15% of rdg + 0.3°C) ResistanceT emperatureDetectorJPt100-2 - 200.0 ~ 200.0°C ±(0.15% of rdg + 0.2°C)0.1°CDigital accuracy ±(0.3% of span)Note 1: 400 ~ 600°C: ± 2°CA range under a span of 400°C: Accuracy is out of guaranteeNote 2: 0 ~ 100°C: ± 3.7°C 100 ~ 300°C, ± 1.5°C Note 3: - 200 ~ -100°C: ± (0.15% of rdg + 1°C) Note 4: - 200 ~ -100°C: ± (0.15% of rdg + 0.7°C) Note 5: 1 ~ 20 K: ±2.4 KNote 6: 0 ~ 300°C: ± 37.6°C 300 ~ 800°C, ±18.8°C Note 7: - 200 ~ -100°C: ± (0.15% of rdg + 0.7°C)STANDARD FUNCTIONSItem Description Analog recording Pen Models: Continuous pen tracingMulti point Model: Dot printing with 6-color ribbon cartridgeDigital display Indicates channel no., processvariable, date, chart speed, alarm setpoint in front display.Logging print Prints date, time, scale, chart speed,each channel’s process variable andengineering unit at a programmedinterval.List print Prints chart speed, type of input, range,engineering unit, alarm set point,comment print status, Printingdescription, logging print ON/OFFconfiguration, ZONE recordingconfiguration, point focus configurationEngineering list print Prints configuration of channel/tag print switch, alarm print, logging print ON/OFF, reference time, interval, alarm hysteresis, burnout protection, scaling print ON/OFF, DI function (option)Affix print (Multipoint Model) Prints Channel number besides analog recording line.Manual print Prints measured data by the front keyoperation. Analog recording stopsduring manual printing.Skip (Multipoint model) Abandon dot print of inputs as required.Programming Programs chart speed, alarm setpoint, logging print interval, skip, dateand time.Memory Backup Back-up for clock by built-in lithiumbattery for 10 years, 5 years inunpowered state.A non-volatile memory storesconfiguration and calibration data. Alarm Sets 2 types (H, L) of alarms perchannel. Sets a total of 4 levels. Chart Speed Selects Chart speed from 41 types. Clock Indication Indicates Y ear, Month, Day, Hour andMinute. Sets the year in A.D, andadjusts leap year automatically.Self Diagnostics Occurring some type of the defect toindicate “ERROR”.Scaling Indicates and record the input of aunification signal etc. is changed intothe engineering scales. CONFIGURABLE FUNCTIONSFunction Description Burnout protection Sets pointer at over 100% perinputs when input becomesopen for T/C or ±50mV max.input.T ag Number T ag number up to 5 charactersfor pen models/7 characters formultipoint model per channelcan be programmed, and printsat logging print.T emperatureCompensationInside/outside of referencejunction compensation (DE/DHconnection) can be specified.Copy Function Channel configuration data canbe copied to another channel.Input offset Input offset per channel can beprogrammed.ZONE Recording Recording on the chart track inspecified range per channel.Point focus recording Recording by point focus to1-crease line per channel.Decade Recording •IndicatingRecords and indicates up to 5decades. 2 figures of effectivenumber to indicate and print.Alarm print Prints time, channel number,setting number and type ofalarm in alarming.Alarm recovery print Prints recovery time, recoverychannel number, settingnumber and type of alarm atrecovery.Record start/end print Prints time and comment(“Start” or “End”) when recordbeginning or end.Square root Square root available.Integration Sum, balance, average amongchannels can be integrated.Damping(Pen Model)Digital filtering for measureddata (PV) in unsteady process.Filter constant range ability:1.0000 to 0.0001Formula is: k = 0.64/T Ik = Filter constantT I= 99.5% dampingAlarm Hysteresis Width Alarm hysteresis width can beprogrammed at 0% FS or 0.5%FS.DIMENSIONSPanel Cutout (mm)TERMINAL ARRANGEMENTMultipoint ModelPen ModelLN 1A 2 C 2 A 1 C 3 A 4 C 4A 3 C 5 A 6 C 6 A 5 C 4 +B4- B 4 A 5+B 5 - B 5 A 6+B 6- B 6 A 1 + B 1 - B1 A2 + B 2 - B 2 A 3+B 3- B3 ASG R D T D +– D I C O M D I 3 D I2 D I 1 LN1A 2 C 2 A 1 C 3 A 3 C 1+B 1-B 1A 2+B 2-B 2ASG R D T D + –D I C O M D I 3 D I2 D I 1T h e r m o c o u p l e i n p u t+-R T D i n p u tm A i n p u t m V , V i n p u t + + +A B bS h unt resistor R2 5 0Ω <Charged HMSU3081A11>+ - + - --Power GroundLN AC I N 7max.(Panel thickness)25150(Unit = mm)1 4 41 4 43 . 52 . 5CH, NO.DA T ARUN M E NU P RINT F E E D E NT200 min.200 m i n .138 138 –0+1 –0+1MODEL CODE NUMBER(Note 1) Combination of RS-232C and RS-485 unavailable.(Note 2) Nos. of relay outputs:6 point recorder 6 relays; Pen recorder 3 relaysCAUTIONDo not install this device before consulting instruction manualSpecifications are subject to change without notice.For further information, a quotation or a demonstration please contact to:Head Office / Factory Saitama, JAP ANSales Offices T okyo, Osaka, Nagoya, Kyushu, T ohokuURL http://www.ohkura.co.jp/e-mail (in English) ******************.jpPrinted in Japan: Aug. 2006。
萨特利斯斯泰迪姆生物技术公司Biostat RM TX产品说明书
Engineered for Life –BIOSTAT ® RM TX with Flexsafe® RM TX for Culturing Consistent Quality Cellular ProductsThe fight against cancer has taken a dra-matic step forward in recent years with the development of cellular immunotherapies such as CAR-T cells. To produce these cells to a consistent quality, manufacturers face issues including: maintaining product sterility, protecting the cell product from adverse stress or environment and maxi-mizing cell yield with efficient processing. These can be achieved with gentle expan-sion and harvesting techniques, in process controls and the use of bioanalytics to ensure lot-to-lot consistency, characterize the cellular product, as well as utilizing rapid and robust lot release testing methods.Our Competence in Cell and Gene TherapySartorius Stedim Biotech is a global solution provider to the biologics industry and is well positioned to support regenerative medicine companies with our tried and trusted technologies for applications in this sector. Utilizing our strong expertise in single-use technology and biopharmaceutical automation, Sartorius supports the development, analysis and manufacture of various types of regenerative medicines, including cellular immunotherapies.Sartorius provides a wide range of plat-forms to address the unique challenges around the production of both allogeneic and autologous cells.Solutions for Cellular ImmunotherapiesBIOSTAT ® RM TX bioreactor system and Flexsafe® RM TX bags –The Ideal Combination for Your CellsThe BIOSTAT ® RM TX and Flexsafe® RM TX bag combination provides you with an automated, wave-mixed and closed environment suitable for optimal growth of cell products in working volumes up to 5 L.The BIOSTAT ® RM TX system consists ofan automated control unit (based on our well-established BIOSTAT ® B) and a rocking platform, for gently agitating a single-use Flexsafe® RM TX bag. Enabling the ex vivo expansion of patient-specific T cells or other types of immune cells, the BIOSTAT ® RM TX is suitable for process development, as well as for the expansion of relevant cell numbers. Fed-batch, perfusion processes or a combination of culture modes are all possible with this system. You Can Rely on:– P roven industry leading Flexsafe® RM TX film that supports consistent cell growth – C losed system for minimal contamination risk– U nique gravity harvesting for maximizing cell recovery– A dvanced, automated system for walk-away monitoring and control of the cell culture including online biomass– P roven rocking motion platform for optimal cell growthBIOSTAT ® RM TX and Flexsafe® RM TX bags are for research use or further manufacturing use only – not for use in therapeutic or diagnostic procedures. They are not CE marked for in vitro diagnostic use nor are they medical devices. Drug manufacturers and clinicians are responsible for obtaining the appropriate IND | BLA | NDA approvals for clinicalapplications.The Right Solution for Your NeedsAt Sartorius, we help you develop a scalable, cost-effective process and combine this with the security of our worldwide supply chain and manufacturing capabilities. Product development in close cooperation with external industry partners guarantees the reliability of your equipment. Our expertise and experience allow us to provide you with a proven product portfolio to support early stage process development and establish scalable processes.Minimize Impact of Single-Use Material Flexsafe ® RM TX bags were introduced in June 2014 and have been used with con-tinuing success ever since by major global biopharma and cell therapy customers. The complete control of our raw materials, the extrusion process and the bag assembly, provides lot-to-lot product consistency. In collaboration with our resin and film suppliers, we have optimized the resin and minimized the additives in our Flexsafe ® film technology* ensuring excellent, reproducible batch-to-batch culture performance of even the most sensitive cells.**Protect Your Cell Product– A perfusion membrane (PES, 1.2 µm) is fixed at the bottom of the bag, forming a compartment for removal of cell free media during the perfusion process – for minimal loss or damage to the cells – S ingle-use sensors for pH, DO and viable biomass enable sophisticated process control with reduced sampling need – 100% integrity tested, gamma-irradiat-able and fully validated Sartopore ® Air sterile filters continuously protect the culture from contamination– I ndustry standard tubing option(DEHP free PVC) for seamless connection to up- & downstream processes* I ndependent labs have confirmed that Flexsafe ® bags are free of cytotoxic leachables. No bDtBPP is identified in WFI extracts of Flexsafe ® bags ** F enge et al. 2014. Consistently Superior Cell Growth: Achieved with New Polyethylene Film Formulation. Bioprocess International, Volume 12 Suppl 5.Zero Slipping Agents & Nontoxic Mechanical Antiblocking k N o risk of interference due to these agents*Optimize Cell GrowthRobust & Consistent Manufacturing Our BIOSTAT ® B control unit is ideal for walk-away automated analysis and control of high cell density perfusion cultures. Benefit from:– A dvanced control and monitoring of gas mixture and flow rate, filling volume and substrate addition; parallel activation of multiple controllers provides maximum flexibility– O n-line viable biomass analysis with culture volumes greater than 500 mL – U p to 4 internal pumps can be integrated into control loops for ease of operation without the need to constantly change the pumps' function.– E asy connection to industry standard Distributed Control (DCS) or Supervisory Control and Data Acquisition (SCADA) systems such as BioPAT ® MFCS, Siemens PCS 7 or Emerson DeltaV™.Straightforward integration into existing automation and single-use infrastructure for data and process consistency throughout– C omplete qualification of the system for GMP use to support regulatory complianceMaximize Cell YieldConventional harvesting procedures mostly use pumping which can reduce the number of live cells and affect cell viability. Since cell yield is critical for autologous cell therapies, we have designed our Flexsafe ® RM TX bags with a special port for hands-free gravity harvesting. This unique gravity harvesting concept in combination with the Flexsafe ® RM TX Harvest Device allows the safe recovery of as many cells as possible by reducing shear stress on these delicate cells and minimizes contaminationrisks from manual handling.* Patent pending.Viable biomass sensor (BioPAT ® ViaMass) integrated in the Flexsafe ® RM bag – connection to the hard-ware componentEfficient Cell ProcessingFlexsafe ® RM TX Harvest Device for hands-free gravity harvest of the cell culture with maximum recovery.BIOSTAT ® RM TXThe BIOSTAT ® RM TX system in combination with Flexsafe® RM TX bags support theculturing of consistent quality cells and is perfect for small volume autologousprocesses with multi-parallel scale out needs. Using this system, one Flexsafe® RM TX bagcan be controlled and monitored via the BIOSTAT ® B control unit. For scale-out, twoFlexsafe® RM TX bags and two separate rocking platforms can be attached to a twinBIOSTAT ® B control unit.Single | Twin ConfigurationOne controller can run up to twoBIOSTAT ® RM TX completely independentlyto save valuable lab space.12” Touch ScreenEasy-to-use and reliable operation of yourBIOSTAT ® RM TX system due to intuitivedesign of human-machine interface andadvanced touch-screen technology – evenwhile wearing laboratory gloves. IntegratedContains aeration, pumps and temperaturecontrol modules for various applicationneeds. The BioPAT® MFCS multi fermentercontrol system ensures reliable datamanagement and automation.Temperature ControlTogether with the control towerthe integrated temperature controlis optimized for small working volumesand perfusion membrane bags.Easy to UseTwo flap door magnetic lid concept forconvenient access to bag and filters.Handles allow for easy transport.Status LED – full control via DCU tower.Load CellsThe integrated precise load cells are idealfor small volume perfusion processes.The BioPAT® MFCS multi fermentercontrol system or third party SCADAsystem integration (DeltaV™) ensuresreliable data management andautomation.Protects operator & tubing frommechanical hazards of moving tray.Flexsafe ®RM TX BagsDifferent sizes of Flexsafe ® RM bags: 1 L, 2 L and 10 L total volume can be used with the BIOSTAT ® RM TX rocking platform, providing a working volume of up to 5 L. The Flexsafe ® RM TX bag has been intelligently designed with features including a special port for gravity harvesting and an internal cell retention membrane, making it ideal for perfusion culture of cellular products such as CAR-T cells.Vent FiltersSartopore ® Air filters are 100% integrity tested before gamma irradiation for improved process safety.BioPAT ®ViaMassIntegrated sensor for online biomass determination and reduced sampling need.*Perfusion MembraneIntegrated 1.2 membrane for secure cell retention during perfusion processes. No fouling and reduced shear as wave constantly flushes over the bottom fixed filter*.FilmIndustry leading proprietary Flexsafe ® film for optimal cell growth of most sensitive cells.Special harvest port for hands-freegravity harvesting. PVC tubing for seamless connectability to upstream and down-stream processes.Single use sensors for advanced process control. No cell accumulation as sensors are inserted from top into the liquid and constantly flushed.* perfusion bag design protected by patents US 9 017 997 B2 and EP 2 268 788 B1Cellular Immunotherapy ProcessesSartorius provides a wide range of single-use technologies. Our portfolio supports viral vector transduction, cell expansion and downstream processing steps including harvest, wash and concentration of cells.AnalyticsSartorius provides various analytical technologies that monitor and control your product during the entire manufacturing process.BIOSTAT STR Flexsafe ® 2D Bags– S ingle-use Flexsafe ® bags for media storage coupled with Flexsafe ® pre-designed solutions for sterile filtration, storage and transfer of media and buffers– P roven integrity to enhance process and product safety by reducing risks of contamination of valuable cell products BioPAT ® MFCS– W orld standard for supervisory process control with GAMP category 4 software package BIOSTAT STR ®– S calable, single-use bioreactor family based on stirred-tank design – W ide range of sizes (12.5 L to 2000 L working volume) and process regimes for flexible manufacturing kSep ® Centrifuge– C losed seal-less single-use fluidized bed centrifugation platform– T he opposing centrifugal and fluid flow mechanism provides low shear force which is ideal for wash & harvest of sensitive cells Biowelder ® TC– A utomated welder for sterile connection of dry or liquid filled thermoplastic tubing to support a functionally closed processProcessiQue ® Screener PLUS Platform Virus Counter ® 3100BioPAT ® Trace*Alternative:Sartorius Transfer SetsMicrosart® ATMP Mycoplasmaand Bacteria KitsCharacterization & CellBanking Services BioPAT® ViaMassService Level Agreement: All-Inclusive Coverage for Maximum Process SecurityOur Comprehensive Service Level Agreement offers the highest level of protection for your critical process equipment. Experience our worry-free contract support including our quickest reaction times and full cost coverage, in addition to the planned preventa-tive maintenance. Benefit from our technical helpdesk response within 4 hours and on-site response within 48 hours.We are working closely with customers to fully understand their needs, so we can help them address these during the early phase of their process development.We apply innovative design approaches to new product developments and test early so there is the opportunity to influence and adjust the scope.We hear what our customers tell us and are committed to serve their needs in the best possible way from start to end of the manufacturing process.Technical helpdesk response within 4 hours and on-site response within 48 hoursReaction Time Commitment:Sartorius as Your Partner for Cell and Gene Therapy ManufacturingTechnical Specifications BIOSTAT ® RM TXPower Supply (Country Specific) | Frequency | Electricity Consumption | Protection Class Rocker platform 230 V | 50 Hz | 1.3 A | IP23or120 V | 60 Hz | 2.5 A | IP23Control tower 230 V | 50 Hz | 10 A | IP21or120 V | 60 Hz | 12 A | IP21Load cells Integrated in rocker Gas Supply via BIOSTAT B Tower Inlet pressure (barg)1.5Connection hose coupling, externalHose barb for tubing with 6 mm IDGas Specification According to ISO 8573-1: dry, free of oil and dust Particle size: < 0.1 mm •Max. amount 0.1 mg/m3 (class 1) •Condensate: dew point < 3°C (class 4)•Oil < 0.01 mg/m3 (class 1) •Germs (class 0)•Operative EnvironmentAmbient temperature of between 5 – 40°CRelative humidity [%]< 80% for temperatures up to 31 °C (87.8 °F),decreasing linearly < 50% at 40 °C (104 °F)Facility and Utility RequirementsTotal Volume1 L2 L 10 L Working volume [L]*0.1 – 0.50.2 – 1 1 – 5Basic Bags for cultivations under constant conditions •••Optical Bags with SU pH & DO sensors••Perfusion Membrane Bags with SU pH & DO ••Integrated Viamass Sensor*••Flexsafe RM TX Design**•Applicable Bag Sizes and Designs* B ags with sensors might require higher minimum working volumes depending on rocking rate and angle. We recommend using 20 % of the total volume as the minimum working volume. ** i ncl. Sartopore Air Midisart vent filters, harvest port for gravity harvest, Press-In Plugs, PVC or C-Flex tubingTemperature Module Temperature controlHeating only – electrical heating plates Temperature control rangeambient temperature + 5°C to 40°C (min. set point 15°C , min. controllable temp = ambient temp. + 15°C)Temperature measurement 2°C to 50°C Temperature control accuracy (excl. measurement error)±0.2°CHeating capacity1 × 120 W (24 VDC)Over temperature protection •Gassing Module Control Tower 4-Gas mix (O 2, N 2, CO 2, air) with headspace outlet MFC– flow rates – accuracymax. 40.003 lpm – 5 lpm ± 1% full scale Advanced DO controller •Sensors & Measurement Temperature probe Pt 100•– temperature range Pt 1000 – 99°C – display resolution 0.1°C– amplifiers 1 (single) | 2 (twin)pH single use•– measurement range 6.5 – 8.5– display resolution 0.1 pH– amplifiers1 (single) |2 (twin)– recalibration function •DO single-use•– measurement range 0 – 250%– display resolution 0.1%– amplifiers1 (single) |2 (twin)– recalibration function•Process ControlDimensions W + D + H Weight MaterialBIOSTAT ® B control Tower Single | Twin 410 × 520 × 810 mm 16 × 20 × 32 in 40 | 55 kg 88 | 121 lbs Stainless steel AISI 304BIOSTAT ® RM TX Rocker complete 439 × 602 × 561 mm 17 × 24 × 22 in 35 kg 77 lbs Stainless steel, ABS Bag holder TX 430 × 602 × 86 mm 17 × 24 × 3.4 in 5.5 kg 12.1 lbs Stainless steel, ABS Lid TX430 × 602 × 495 mm 17 × 24 × 20 in 2.5 kg 5.5 lbsABS Lab-cart (optional)800 × 800 × 900 mm32 × 32 × 36 in 88 kg 194 lbsStainless steelSystem CharacteristicsSensors & MeasurementSingle-use viable biomass(BioPAT® ViaMass)Optional Integrated load cells•Media weight control range0 to 5 kg- Scale, absolute accuracy Static:± (10 + 0% of load) gDynamic:± (25 + 0% of load) g - Scale, relative accuracy Static:±3 gDynamic:±5 g*Resolution (DCU) 1 gExternal signal input max. 20 – 10 V or 4 – 20 mA Pump Module | Built-in PumpsWatson Marlow 114, fast load pump headFixed Speed for Base Addition / pHControl– Speed 5 rpmFlow rate (tubing wall thickness 1.6 mm)ID: 0.5 mm: 0 – 0.1 ml/min ID: 0.8 mm: 0.05 – 2.4 ml/min ID: 1.6 mm: 0.01 – 0.7 ml/min ID: 2.4 mm: 0.03 – 1.5 ml/min ID: 3.2 mm: 0.05 – 2.4 ml/min ID: 4.8 mm: 0.09 – 4.3 ml/minSpeed Controlled for Feed Addition– Speed 5 – 150 rpmFlow rate (tubing wall thickness 1.6 mm)ID: 0.5 mm: 0.1 – 3 ml/min ID: 0.8 mm: 0.2 – 6 ml/min ID: 1.6 mm: 0.7 – 21 ml/min ID: 2.4 mm: 1.45 – 43.5 ml/min ID: 3.2 mm: 2.35 – 70.5 ml/min ID: 4.8 mm: 4.25 – 127.5 ml/min* D ynamic weight measurement (while rocking) can be influenced by cables and tubing and interferences caused by the same.The BIOSTAT ® RM TX system is designed to communicate with industrial SCADA or DCS systems (e.g. DeltaV) through the Modbus TCP/IP protocol.Temperature Module Max. total volume (L)10 Max. working volume (L)5Rocking speed control range [rpm] 2 – 42 rpm ±1Rocking angle control range (°) 2 – 12 ± 0.3Clamping rails for bag fixation •Sensor clamps for secure fixation of glass fiber cables •Filter heater(2 variants: for std. Hepa filter or for Midisart Sartopore Air)•Safety measurement and shut-off 30 mbar Additional safety valve gasses (mbar)100 mbarWater inlet pressure reduction value 1.5 bar, integrated pressure control Different user level log in (•)Logbook function(•)Lab-cart for BIOSTAT ® B Control TowerSeparately available on requestTechnical DataCommunicationSales and Service Contacts For further contacts, visit EuropeGermanySartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 GoettingenPhone +49.551.308.0Sartorius Stedim Systems GmbH Robert-Bosch-Strasse 5 – 7 34302 GuxhagenPhone +49.5665.407.0FranceSartorius Stedim FMT S.A.S.ZI des PaludsAvenue de Jouques – CS 91051 13781 Aubagne Cedex Phone +33.442.845600 Sartorius Stedim France SASZI des PaludsAvenue de Jouques – CS 71058 13781 Aubagne Cedex Phone +33.442.845600 AustriaSartorius Stedim Austria GmbH Modecenterstrasse 221030 ViennaPhone +43.1.7965763.18BelgiumSartorius Stedim Belgium N.V. Rue Colonel Bourg 1051030 BruxellesPhone +32.2.756.06.80HungarySartorius Stedim Hungária Kft. Kagyló u. 52092 BudakesziPhone +36.23.457.227ItalySartorius Stedim Italy S.r.l.Via dell’Antella, 76/A50012 Antella-Bagno a Ripoli (FI)Phone +39.055.63.40.41NetherlandsSartorius Stedim Netherlands B.V.Phone +31.30.60.25.080****************************************PolandSartorius Stedim Poland Sp. z o.o.ul. Wrzesinska 7062-025 KostrzynPhone +48.61.647.38.40Russian FederationLLC “Sartorius Stedim RUS”Vasilyevsky Island5th line 70, Lit. A199178 St. PetersburgPhone +7.812.327.53.27SpainSartorius Stedim Spain, S.A.U.Avda. de la Industria, 32Edificio PAYMA28108 Alcobendas (Madrid)Phone +34.913.586.098SwitzerlandSartorius Stedim Switzerland AGRingstrasse 24 a8317 TagelswangenPhone +41.52.354.36.36U.K.Sartorius Stedim UK Ltd.Longmead Business CentreBlenheim Road, EpsomSurrey KT19 9 QQPhone +44.1372.737159UkraineLLC “Sartorius Stedim RUS”Post Box 440 “B”01001 Kiev, UkrainePhone +380.44.411.4918AmericasUSASartorius Stedim North America Inc.5 Orville Drive, Suite 200Bohemia, NY 11716Toll-Free +1.800.368.7178ArgentinaSartorius Argentina S.A.Int. A. Ávalos 4251B1605ECS MunroBuenos AiresPhone +54.11.4721.0505BrazilSartorius do Brasil LtdaAvenida Senador Vergueiro 2962São Bernardo do CampoCEP 09600-000 - SP- BrasilPhone +55.11.4362.8900MexicoSartorius de México, S.A. de C.V.Libramiento Norte de Tepotzotlan s/n,Colonia Barrio Tlacateco,Municipio de Tepotzotlan,Estado de México,C.P. 54605Phone +52.55.5562.1102**********************Asia|PacificAustraliaSartorius Stedim Australia Pty. Ltd.Unit 5, 7-11 Rodeo DriveDandenong South Vic 3175Phone +61.3.8762.1800ChinaSartorius Stedim (Shanghai)Trading Co., Ltd.3rd Floor, North Wing, Tower 1No. 4560 Jinke RoadZhangjiang Hi-Tech ParkPudong DistrictShanghai 201210, P.R. ChinaPhone +86.21.6878.2300Sartorius Stedim (Shanghai)Trading Co., Ltd.Beijing Branch OfficeNo. 33 Yu’an RoadAirport Industrial Park Zone BShunyi District, Beijing 101300Phone +86.10.8042.6501Sartorius Stedim (Shanghai)Trading Co., Ltd.Guangzhou Branch OfficeRoom 1105Xing Guang Ying Jing BuildingNo. 119, Shui Yin RoadYue Xiu District, Guangzhou 510075Phone +86.20.3836.4193IndiaSartorius Stedim India Pvt. Ltd.#69/2-69/3, NH 48, JakkasandraNelamangala Tq562 123 Bangalore, IndiaPhone +91.80.4350.5250JapanSartorius Stedim Japan K.K.4th Fl., Daiwa Shinagawa North Bldg.8-11, Kita-Shinagawa 1-chomeShinagawa-ku, Tokyo, 140-0001 JapanPhone +81.3.4331.4300MalaysiaSartorius Stedim Malaysia Sdn. Bhd.Lot L3-E-3B, Enterprise 4Technology Park MalaysiaBukit Jalil57000 Kuala Lumpur, MalaysiaPhone +60.3.8996.0622SingaporeSartorius Stedim Singapore Pte. Ltd.10 Science Park RdThe Alpha #02-13/14Singapore Science Park IISingapore 117684Phone +65.6872.3966South KoreaSartorius Korea Biotech Co., Ltd.8th Floor, Solid Space B/D,PanGyoYeok-Ro 220, BunDang-GuSeongNam-Si, GyeongGi-Do, 463-400Phone +82.31.622.5700 S p e c i f icationssubjecttochangewithoutnotice.CopyrightSartoriusStedimBiotechGmbH.PrintedintheEUonpaperbleachedwithoutchlorine.Version1/219/1。
2N5484中文资料
**L2 **L3
6 turns, (approx. — depends upon circuit layout) AWG #24 enameled copper wire, close wound on 7/32″ ceramic coil form. Tuning provided by an aluminum slug. 1 turn, AWG #16 enameled copper wire, 3/8″ I.D. (AIR CORE). 1/2 turn, AWG #16 enameled copper wire, 1/4″ I.D. (AIR CORE).
POWER GAIN
24 f = 100 MHz
20 PG , POWER GAIN (dB)
16
12
400 MHz Tchannel = 25°C VDS = 15 Vdc VGS = 0 V 0 2.0 4.0 6.0 8.0 10 ID, DRAIN CURRENT (mA) 12 14
8.0 4.0
Figure 2. 100 MHz and 400 MHz Neutralized Test Circuit
NOISE FIGURE
(Tchannel = 25°C)
10 ID = 5.0 mA 8.0 NF, NOISE FIGURE (dB) NF, NOISE FIGURE (dB) 5.5 6.5 VDS = 15 V VGS = 0 V
1 2 3
CASE 29–04, STYLE 5 TO–92 (TO–226AA)
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise noted)
N-SMP25-50系列23-24
D C/D C 电源模块输入电压(VDC )输出电压(VDC )输出电流(A )N-SMP -1251SA 9-185.055N-SMP -1252SA 9-18122.08N-SMP -1253SA 9-18151.6N-SMP -1251SB 18-365.055N-SMP -1252SB 18-36122.08N-SMP -1253SB 18-36151.67N-SMP -1251SC 36-725.055N-SMP -1252SC 36-72122.08N-SMP -1253SC 36-72151.6N-SMP -1251DB 18-36+5.05/-5.05+4/-1N-SMP -1252DB 18-36+12/-12+1.6/-0.5N-SMP -1251DC 36-72+5.05/-5.05+4/-1N-SMP -1252DC 36-72+12/-12+1.6/-0.5N-SMP -1252TD 66-160+5.1/+12.6/-12.6+4/+0.25/-0.25N-SMP -1253TD 66-160+5.1/+15/-15+4/+0.2/-0.2N-SMP -1252QC 36-72+5.1/-5.3/+12.6/-12.6+3.5/-0.5/+0.25/-0.25N-SMP -1351SB 18-365.17N-SMP -1352SB 18-36123N-SMP -1351SC 36-725.17N-SMP -1352SC 36-72123N-SMP -1351DB 18-36+5.1/-5.1+6/-1N-SMP -1352DB 18-36+12/-12+2.5/-0.5N-SMP -1352QC 36-72+5.1/-5.3/+12.6/-12.6+4/-1/+0.5/-0.5N-SMP -1353QC 36-72+5.1/-5.3/+15.2/-15.2+4/-1/+0.4/-0.4N-SMP -1352TD 66-160+5.1/+12.6/-12.6+5/+0.5/-0.5N-SMP -1501SA 9-185.110N-SMP -1502DB 18-36+12/-12+3.4/-0.8N-SMP -1503DB 18-36+15/-15+2.7/-0.7N-SMP -1501DD 66-160+5.1/-5.1+8/-2N-SMP -1502DD 66-160+12/-12+3/-0.8N-SMP -1503DD 66-160+15/-15+2.7/-0.7型号效率(%)80838184848485858485858585868585868483858585858580838385858679NAS25-12-W NAS25-12-W 输出功率NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W 纹波与噪声NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W NAS25-12-W N -SMP25-50系列DC /DC 电源模块宽电压输入范围广范应用,通讯,测控,军工技术参数产品选型封装尺寸引脚功能D C /D C 电源模块单位:mm (inch )公差:±0.30mm (±0.010inch )25W 40W 35W 50W 定义123456789101112131415单路+vin +vin -vin -vin case cnt -s trim +s nc nc -vo -vo +vo +vo双路+vin +vin -vin -vin case cnt -s trim +s vo2vo2com com vo1vo1叁路+vin +vin -vin -vin case cnt vo3com vo2nc nc -vo1-vo1+vo1+vo1肆路+vin +vin -vin -vin case cnt vo4com vo3vo2vo2com com vo1vo1001001023024www .jsygpower .com www .jsygpower .com 81.28(3.200)101.6 (4.00)5.08(0.200)10.16(0.400)7.62(0.300)7.62(0.300)10.16(0.400)5.08(0.200)10.16(0.400)5.08(0.200)76.2 (3.00)14.0(0.55)0.8 (0.03)3.3(0.13)MIN. 151413121110987654321底视图15-φ1.0±0.1标称最大条件输入特性NAS25-12-W 91218NAS25-12-W 182436NAS25-12-W 364872NAS25-12-W 66110160输出特性最小标称最大条件±1%V01±3%V02 NAS25-12-W ±0.2%V01NAS25-12-W ±1.5%V02 NAS25-12-W ±0.5%V01NAS25-12-W ±4%V02 NAS25-12-W 3±%动态过冲福度阶跃负载50%-75%NAS25-12-W 200us 动态恢复时间阶跃负载50%-25%NAS25-12-W 50mvp -p V0≤5VDC 示波器20M 带宽NAS25-12-W 100mvp -p Other NAS25-12-W 200mvp -p V0≥48VDC 示波器20M 带宽温度系数环境特性最小标称最大条件工作温度-40℃+95℃工业级NAS25-12-W -40℃+95℃军品一级(J1)NAS25-12-W -40℃+95℃军品二级(J2)代报告书NAS25-12-W -55℃+105℃军品三级(J3)代报告书存储温度-55℃+125℃相对湿度10%90%最小NAS25-12-W 输出电压精度输出电压精度源效应负载效应动态响应纹波与噪声工作温度输入电压vdc NAS25-12-W 开通NAS25-12-W 关断摇控cnt 悬空或接ttl 高电平cnt 与-vin 相连电压调节±10%±0.02%℃V01一般特性最小标称最大条件天关频率300khz 隔离电压1500vdc(输入对输出)1分钟,漏电流小于0.5ma NAS25-12-W 1500vdc(输入对壳)1分钟,漏电流小于0.5ma NAS25-12-W 500vdc(输出对壳)1分钟,漏电流小于0.5ma 绝缘电阻振动隔离电压平均无故障时间62×10h 重量100M Ω输入-输出,绝缘电压500Vdc 10-55Hz ,10G 30Min ,alongX ,YandZ 200g Bellcore TR332,25℃输入输出隔离耐压1500VDC,输出短路,自恢复裸机满足 CISPR22/EN55022 CLASS A 环保设计,符合 指令RoHS。
海运专业名词中英文对照
海运专业名词英文对照A/W 全水路All WaterANER 亚洲北美东行运费协定Asia NorthAmerica EastboundRate B/L 海运提单Bill of LadingB/R 买价Buying RateBAF 燃油附加费Bunker AdjustmentFactorC&F 成本加海运费COST AND FREIGHTC.C 运费到付CollectC.S.C 货柜服务费Container Service ChargeC.Y. 货柜场Container YardC/(CNEE) 收货人ConsigneeC/O 产地证Certificate of OriginCAF 货币汇率附加费Currency Adjustment FactorCFS 散货仓库Container Freight StationCFS/CFS 散装交货(起点/终点)CHB 报关行Customs House BrokerCIF 成本,保险加海运费COST,INSURANCE,FRIGHTCIP 运费、保险费付至目的地Carriage and Insurance Paid To COMM 商品CommodityCPT 运费付至目的地Carriage Paid ToCTNR 柜子ContainerCY/CY 整柜交货(起点/终点)D/A 承兑交单Document Against AcceptanceD/O 到港通知Delivery OrderD/P 付款交单Document Against PaymentDAF 边境交货Delivered At FrontierDDC 目的港码头费Destination Delivery ChargeDDP 完税后交货Delivered Duty PaidDDU 未完税交货Delivered Duty Unpaid DEQ 目的港码头交货Delivered Ex QuayDES 目的港船上交货Delivered Ex ShipDoc# 文件号码Document NumberEPS 设备位置附加费Equipment Position SurchargesEx 工厂交货Work/ExFactoryF/F 货运代理Freight ForwarderFAF 燃料附加费Fuel AdjustmentFactorFAK 各种货品Freight All KindFAS 装运港船边交货Free Alongside ShipFCA 货交承运人Free CarrierFCL 整柜Full Container LoadFeeder Vessel/Lighter 驳船航次FEU 40\'柜型Forty-Foot Equivalent Unit 40\'FMC 联邦海事委员会Federal Maritime CommissionFOB 船上交货Free On BoardGRI 全面涨价General RateIncreaseH/C 代理费Handling ChargeHBL 子提单House B/LI/S 内销售Inside SalesIA 各别调价Independent ActionL/C 信用证Letter of CreditLand Bridge 陆桥LCL 拼柜Less Than Container LoadM/T 尺码吨(即货物收费以尺码计费)Measurement Ton MB/L 主提单Master Bill Of LoadingMLB 小陆桥,自一港到另一港口Minni Land Bridge Mother Vessel 主线船MTD 多式联运单据Multimodal Transport DocumentN/F 通知人NotifyNVOCC 无船承运人Non Vessel OperatingCommon CarrierO/F 海运费Ocean FreightOBL 海运提单Ocean (or original B/L)OCP 货主自行安排运到内陆点Overland Continental PointOP 操作OperationORC 本地收货费用(广东省收取)Origen Recevie ChargesP.P 预付PrepaidPCS 港口拥挤附加费Port Congestion SurchargePOD 目地港Port Of DestinationPOL 装运港Port Of LoadingPSS 旺季附加费Peak Season SuchargesS/(Shpr) 发货人ShipperS/C 售货合同Sales ContractS/O 装货指示书Shipping OrderS/R 卖价Selling RateS/S Spread Sheet Spread SheetSC 服务合同Service ContractSSL 船公司Steam Ship LineT.O.C 码头操作费Terminal Operations OptionT.R.C 码头收柜费Terminal Receiving ChargeT/S 转船,转运Trans-ShipT/T 航程Transit TimeTEU 20\'柜型Twenty-Foot Equivalent Unit 20\'THC 码头操作费(香港收取) Terminal Handling ChargesTTL 总共TotalTVC/ TVR 定期定量合同Time Volume Contract/ RateVOCC 船公司Vessel Operating Common CarrierW/M 即以重量吨或者尺码吨中从高收费Weight or Measurement tonW/T 重量吨(即货物收费以重量计费) Weight TonYAS 码头附加费Yard Surcharges 海运费ocean freight集卡运费、短驳费Drayage订舱费booking charge报关费customs clearance fee操作劳务费labour fee or handling charge商检换单费exchange fee for CIP换单费D/O fee拆箱费De-vanning charge港杂费port sur-charge电放费B/L surrender fee冲关费emergent declearation change海关查验费customs inspection fee待时费waiting charge仓储费storage fee改单费amendment charge拼箱服务费LCL service charge动、植检疫费animal & plant quarantine fee 移动式其重机费mobile crane charge进出库费warehouse in/out charge提箱费container stuffing charge滞期费demurrage charge滞箱费container detention charge卡车运费cartage fee商检费commodity inspection fee转运费transportation charge污箱费container dirtyness change坏箱费用container damage charge清洁箱费container clearance charge分拨费dispatch charge车上交货FOT ( free on track )电汇手续费T/T fee转境费/过境费I/E bonded charge空运方面的专用术语空运费air freight机场费air terminal charge空运提单费airway bill feeFSC (燃油附加费) fuel surchargeSCC(安全附加费)security sur-charge抽单费D/O fee上海港常用术语内装箱费container loading charge(including inland drayage)疏港费port congestion charge他港常用术语场站费CFS charge文件费document charge物流费用分析常见的物流费用包括以下几种:海洋运费:Ocean Freight, 从装运港到卸货港的海洋运输费用,按照货物运输方式及性质计价方式回不一样,如集装箱运输,按照每个集装箱收费,集装箱分为普通干箱(General Purpose, Dry)和特种集装箱,按照集装箱大小分为20’, 40’, 20’H(High, 高箱), 40’H(High,高箱),45’等;特种集装箱分为挂衣箱、平板箱、框架箱、冷冻箱、开顶箱、半封闭箱等。
RM6204中文规格书资料
英寸 典型值
0.130 0.060 0.018 0.365 0.300 0.250 0.100 0.130 0.355
7°
最大值
0.210
0.135
0.400
0.255
0.150 0.375 15°
2012-6-4
7
note2 JA
………………………………70℃/W
注: 1.测试点选择靠近7、8脚, 2. 7、8脚处不能少于200 mm2 的铜皮;
2012-6-4
3
电气特性
测试条件: T=25℃,,VCC=5.5-7.5V, RS=1Ω;
参数
符号
条件
输出
开关管最大耐压
Ioc=10mA
饱和压降 输出上升时间 输出下降时间 输出限制电流
当功率管截止时,内部电路将功率管反向 偏置,利用双极性晶体管 CB 的耐高压特性来提 高 OC 脚的耐压能力,从而确保功率管的安全 性。
RM6204 内部设计了多款保护功能,如:过 载保护、输出短路保护、过温保护、VCC 脚过 压保护等。
RM6204 采用标准的 DIP-8 封装形式。
■内置800V高压三极管;; ■应用电路设计简单,元器件少; ■内置锁存脉宽调制和逐脉冲电流检测技术; ■低电压降频且待机功耗小于0.3W; ■内置斜坡补偿、反馈补偿功能; ■内置独立上限电流检测电路,实时处理过流
9.017
6.223
2.921 8.509
0°
毫米 典型值
3.302 1.524 0.457 9.271 7.620 6.350 2.540 3.302 9.017
7°
最大值
5.334
3.429
10.160
CR5224
高压功率 MOSFET 部分
BVdss
MOSFET 漏源击穿电压
VGS=0V, IDS=250uA
630
V
RDS(on)*
漏源之间静态导通电阻
VGS=10V, IDS=1A
5.0 5.8
Ω
频率抖动部分
△f_SOC 频率抖动范围
过温保护部分
TOTP
过温保护点
-4
4
%
160
0C
* 集成化功率 MOSFET 的内阻和封装形式、散热、环境温度都有关系,本说明书所给值为室温 下分立封装的 MOSFET 内阻。
成都启臣微电子有限公司 1/8
CR5224
引脚排列图
绿色节能电流模反激 PWM 功率开关
引脚描述
名称 GND
FB
VDDG SENSE VDD
Drain
描述 地。 反馈输入引脚。PWM 控制器的占空比由此引脚上的反馈电压和 SENSE 引脚上 的检测电压共同决定。 内部栅极驱动电源输入。 电流采样输入。 芯片电源。 高压 MOSFET 漏极,连接在变压器初级侧线圈一端,线圈另一端接整流输入 电容阳极。
典型应用
启达科技(成都)有限公司 V1.3
成都启臣微电子有限公司 2/8
CR5224
功能框图
绿色节能电流模反激 PWM 功率开关
极限参数
符号 VDD VDDG VDrain IVDD VFB VSense
ESD
TL
TSTG TJ
参数
工作电压
功率输出电路的电源电压
高压MOSFET漏端电压(关闭状态)
正常的振荡频率 温度与频率稳定性 VDD 电压与频率稳定性 最大占空比 Burst Mode 频率
RM805024中文资料
F0165-AV REG.-Nr. 40003144, Z E214025Contact data RM8Contact configuration 2 CO contactsContact set single contactType of interruption micro disconnectionRated current25ARated voltage / max.switching voltage AC 400VACMaximum breaking capacity AC 6000VALimiting making capacity, max 20 ms60AContact material AgCdOMechanical endurance 10x106cyclesRated frequency of operation with / without load 16/100min-1Contact ratingsType Load CyclesRM8025A, 415VAC, UL10x103RM8025A, 250VAC, cosϕ=1, 35°C, VDE10x103RM8025A, 240VAC, 1-phase, per pole, general purpose, UL6x103Coil dataAC coil 6...400VACAC coil 2.8VAOperative range 1Coil versions,DC-coilSTD LED PD*LED+voltage voltage voltage resistance powerbipolar PD*VDC VDC VDC Ohm W006L060A6LA66 4.50.632+10% 1.1012L120B2LB2129.0 1.2110+10% 1.3024L240C4LC42418.0 2.4475+10%1.2048L480E8LE84836.0 4.82000+10% 1.2060L600G0LG06045.0 6.02850+10% 1.3110M101B0MB011082.511.010000+12% 1.2221N212C1NC1220165.022.040000+15% 1.2*) Protection diode PD; standard polarity: +A1/-A2Terminal assignmentBottom view on pinsS0269-ADCoil versions,AC-coil 50/60Hz Coil code Rated Operate Release Coil Rated coilSTD LED voltagevoltage voltage resistance power 50/60Hz 50/60Hz 50/60HzVAC VAC VAC Ohm VA506R066 4.8 2.4 4.7+10% 2.86/2.36512R12129.6 4.819.5+10% 2.71/2.27524R242419.29.680+10% 2.62/2.00548R484838.419.2320+10% 2.60/2.17560R606048.024.0500+10% 2.62/2.20615S1511592.046.01850+10% 2.65/2.22730T30230184.092.07500+10% 2.69/2.26900V00400320.0160.023500+15% 2.61/2.20All figures are given for coil without preenergization, at ambient temperature +23°CInsulationDielectric strength coil-contact circuit2500V rms open contact circuit1500V rms adjacent contact circuits4000V rms adjacent contact circuitsW 15.3/15.3mmMaterial group of insulation parts W IIIa Insulation to IEC 60664-1Type of insulation coil-contact circuitbasic open contact circuitfunctional adjacent contact circuitsbasic Rated insulation voltage 250V Pollution degree3Rated voltage system 240/400VOvervoltage categoryIIIOther dataRoHS - Directive 2002/95/EC compliant as per product date code 0415Ambient temperature range DC coil -45...+65°CAC coil -45...+40°COperate- / release time 15/15ms Bounce time NO / NC contact 3ms Vibration resistance (function) NO / NC contact 10/5g, 30...150Hz Category of protection RTI - dust protected Relay weight 81g Packaging unit 10/25pcsDimensionsCover with mounting brackets, 6.3mm quick connect terminals Cover with DIN-snap-on attachementhorizontal verticalS0298-BC S0298-BD S0298-BE。
一节R5402N101KD-TR-F
PRODUCT SPECIFICATIONS R5402N101KD-TR-Fcontents[1] Outline[2] Block Diagram[3] Pin Descriptions[4] Absolute Maximum Ratings[5] Electrical Characteristics[6] Test Circuits[7] Operation[8] Technical Notes[9] Timing Diagrams[10] Package Dimensions[11] Mark Specification[1] OutlineThe R5402N101KD is high voltage tolerance CMOS-based protection IC for over-charge/discharge and over-current of rechargeable one-cell Lithium-ion (Li+)/Lithium polymer battery. The R5402N101KD can detect over-charge/discharge of Li+ one-cell and excess load current, further include a short circuit protector for preventing large external short circuit current and the excess charge-current. The R5402N101KD consists of four voltage detectors, a reference unit, a delay circuit, a short circuit detector, an oscillator, a counter, and a logic circuit.When the R5402N101KD detects over-charge or over-charge current, the output of C OUT pin switches to “L” level, that is, the charger’s negative pin level after the internal fixed delay time. When the R5402N101KD detects over-discharge or excess discharge current, the output of D OUT pin switches to “L” level after the internal fixed delay time.After detecting over-charge voltage or over-charge current, if the battery voltage is lower than over-charge detector threshold voltage, the R5402N101KD can be reset and the output of C OUT becomes “H” when a kind of load is connected to V DD after a charger is disconnected from the battery pack. If a charger is continuously connected to the battery pack, when the cell voltage becomes equal or lower than the release voltage from over-charge, over-charge will be released and C OUT becomes “H”.After detecting over-discharge voltage, connect a charger to the battery pack, and when the battery supply voltage becomes higher than over-discharge detector threshold, or the battery voltage becomes equal or more than the released voltage from over-discharge, the R5402N101KD is released and the voltage of D OUT pin becomes “H”. If the battery discharges into 0V level, recharge current is accepted. Once after detecting excess discharge-current or short circuit, the R5402N101KD is released and D OUT level becomes “H” with detaching a battery pack from a load system. After detecting over-discharge, supply current is kept extremely low by halting internal circuits' operation.When the output of C OUT is "H", by setting the V- pin at equal or lower than the delay time shortening voltage (Typ. -2.0V), the output delay can be shortened. Especially, the delay time of over charge detector can be reduced into approximately 1/60. Thus, testing time of protector circuit board can be reduced. Output type of C OUT and D OUT is CMOS.[2] Block Diagram[3] Pin DescriptionPin No. Symbol Pin description1 D OUT Output of Over-discharge detection, CMOS output2 V-Charger negative Input3 C OUT Output of Over-charge detection, CMOS output4 NCNo Connection5 V DD Power Supply Pin. Substrate level of the IC.6 VssGround Pin. (Ground level of the IC)[4] Absolute Maximum RatingTopt=25°C, Vss=0VItem Symbol Ratings Unit Supply Voltage V DD -0.3 to 12VInput VoltageV- pin Voltage V-V DD-35 to V DD+0.3VOutput VoltageC OUT pin VoltageD OUT pin Voltage V C OUTV D OUTV DD-35 to V DD+0.3Vss-0.3 to V DD+0.3VVPower Dissipation P D 150 mW Operating Temperature Topr -40 to 85 °C Storage Temperature Tstg -55 to 125 °C[5] Electrical Characteristics•R5402N101KDUnless otherwise provided, Topt=25°CItem Symbol Conditions Min.Typ. Max. Unit Note1Operating Input Voltage V DD 1 V DD - Vss 1.5 5.0 V A Minimum Operating Voltage for 0V Charging Vst Voltage Defined as V DD -V-, VDD-Vss=0V 1.8 V A Over-charge Threshold Voltage V DET 1 R1=330Ω R1=330Ω, Topt=-5°C to 55°C *Note24.2254.220 4.250 4.250 4.2754.280V V BB Released voltage from Over-charge V REL 1 R1=330Ω 4.000 4.050 4.100V B Output Delay of Over-chargetV DET 1 V DD =3.6V →4.4V 0.7 1.0 1.3 s B Release Delay for VD1 tV REL 1 V DD =4.5V →3.6V 11 16 21 ms B Over-discharge Threshold V DET 2 Detect falling edge of supply voltage2.438 2.500 2.562V BReleased Voltage from Over-discharge V REL 2 Detect rising edge of supply voltage 2.925 3.000 3.075V C Output Delay of Over-dischargetV DET 2 V DD =3.6V →2.2V 14 20 26 ms D Release Delay for VD2 tV REL 2 V DD =3V, V-=3V →0V 0.7 1.2 1.7 ms D Excess discharge-current thresholdV DET 3 Detect rising edge of 'V-' pin voltage 0.1850.200 0.215V EOutput delay of excess discharge-currenttV DET 3 V DD =3.0V, V-=0V to 0.5V 8 12 16 msF Output delay of releasefrom excess discharge-currenttV REL 3 V DD =3.0V, V-=3V to 0V 0.7 1.2 1.7 msFShort Protection Voltage Vshort V DD =3.0V 0.550.80 1.00 V FDelay Time for Short Protectiontshort V DD =3.0V, V-=0V to 3V230 300 500 µsF Reset Resistance forExcess Current Protection Rshort V DD =3.6V,V- =1.0V 25 50 75 k Ω F Excess charge-current thresholdV DET 4 Detect falling edge of'V-' pin voltage-0.130-0.100 -0.070V F Output delay of excess charge-currenttV DET 4 V DD =3.0V, V-=0V to -1V 5 8 11 ms G Output delay of releasefrom excess charge-currenttV REL 4 V DD =3.0V, V-=-1V to 0V0.71.21.7msGDelay Time Shortening Mode VoltageV DS V DD =4.4V -1.4-2.0 -2.6 V GNch ON-Voltage of C OUT V oL 1 Iol=50µA, V DD =4.5V 0.4 0.5 V G Pch ON-Voltage of C OUT V oH 1 Ioh=-50µA, V DD =3.9V 3.4 3.7 V H Nch ON-Voltage of D OUT V oL 2 Iol=50µA, V DD =2.0V 0.2 0.5 V I Pch ON-Voltage of D OUT V oH 2 Ioh=-50µA, V DD =3.9V 3.4 3.7 V JSupply Current I DD V DD =3.9V, V- =0V 4.0 8.0 µA KStandby C U rrent I standby V DD =2.0V1.22.0 µA L•: ’Note1’ indicates test circuits shown in next page.Note2: Considering of variation in process parameters, we compensate for this characteristicrelated to temperature by laser-trim, however, this specification is guaranteed by design, not mass production tested.[6] Test CircuitsABCEDFIHJKL[7] Operation• VD1 / Over-charge DetectorThe VD1 monitors V DD pin voltage during charge. When the V DD voltage crosses over-charge detector threshold V DET1(Typ. 4.250V), the VD1 can sense over-charge and the output of C OUT pin becomes “L”and stop charging by turning off the external Nch-MOSFET.After detecting over-charge, when the voltage of V DD pin is equal or less than the released voltage from over-charge (Typ. 4.050V), or when the V DD voltage is less than the over-charge detector threshold, if the charger is removed and connect a load, VD1 is released, then the output level of C OUT becomes “H” and by turning on the external Nch-MOSFET, the battery charger is ready to work again.When the Input level of V DD pin is equal or more than over-charge detector threshold, and while a charger is disconnected from the battery pack, if a load system is connected to the battery pack, the output level of C OUT pin is “L”. However, load current can be flown through a parasitic diode of an external Nch-MOSFET. Then, when the voltage level of V DD pin becomes lower than over-charge detector threshold, the output level of C OUT pin becomes “H”.Output delay time for over-charge detect and released over-charge is internally fixed respectively.Although the V DD voltage goes up to a higher level than over-charge detector threshold within the output delay time (Typ. 1s), VD1 would not work for detecting over-charge. If the action for VD1 to release is done and the condition returns to the initial one within the output delay time (Typ.16ms), VD1 cannot be released.A level shifter is built in a buffer driver for the C OUT pin, because of this, the “L” level is equal to thevoltage level of V- pin.The output type of C OUT pin is CMOS type. (The Output level is between V DD and V-.)• VD2/Over-discharge DetectorThe VD2 monitors a V DD pin voltage during discharge. When the V DD voltage crosses the over-discharge detector threshold V DET2(Typ. 2.50V) from a high level to a lower level than V DET2, the VD2 senses over-discharge and stop discharge by turning off an external Nch-MOSFET.To reset the VD2 with the D OUT pin level being “H” again after detecting over-discharge, if V DD voltage is equal or less than over-charge detector threshold, a charge current flows through a parasitic diode of the external Nch MOSFET. After that, when V DD voltage is more than over-discharge threshold, D OUT pin becomes "H", and by tuning on the external Nch MOSFET, discharge is possible. In the case that a charger is connected to the battery pack, and V DD level is more than over-discharge detector threshold, the output level of D OUT becomes “H” immediately. Without connecting a charger, if V DD pin voltage is equal or more than the released voltage from over-discharge (Typ.3.0V), the output level of D OUT becomes “H”.When a cell voltage is equal to 0V, connecting a charger to the battery pack makes C OUT pin become "H" and the system is allowable for charge while the voltage of the charger is more than the maximum limit of the minimum operating voltage (Vst) for 0V charge.An output delay for over-discharge detection is fixed internally. (Typ. 20ms) Although the voltage of V DD becomes equal or less than over-discharge detector threshold and if it becomes higher than over-discharge detector threshold within output delay time, over-discharge detector does not work.Output delay time for release from over-discharge is also set internally. (Typ. 1.2ms)After detecting over-discharge by VD2, supply current would decrease, (V DD=2.0V, Max. 2.0µA.) because unnecessary circuits are halted and being standby.The output type of D OUT pin is CMOS type and its output level is in between V DD and V SS.• VD3/ Excess Discharge Current Detector, Short Circuit Protector While charge and discharge are acceptable with the battery pack, VD3 monitors the voltage level of V- pin. In the cause of such as the external short-circuit, if the voltage level of V- pin may become equal or more than the excess discharge current threshold (Typ. 0.200V) and less than the short detector threshold (Typ. 0.8V), the excess discharge current detector works. When the voltage level of V- pin becomes equal or more than short detector threshold voltage, the short circuit protector works and the output level of D OUT becomes “L”, and by turning off an external Nch MOSFET, VD3 protects against flowing extremely large current into the circuit.An output delay time for the excess discharge current detector is internally fixed at 12ms typical. Although the voltage of V- pin becomes equal or more than the excess discharge current threshold voltage and less than short detector threshold, if it becomes less than the excess current detector threshold voltage within the output delay time, the excess current detector does not work. Output delay time for release from excess discharge current is also set internally (Typ. 1.2ms).In terms of short circuit protector, output delay time is typically 300µs.The V- pin has a built-in pull down resistor, Typ. 50kΩ connected to the Vss pin.After an excess discharge current or short circuit protection is detected, by removing a cause of excess current or external short circuit, the voltage level of V- is pulled down through the resistor for release from excess current to the Vss level. Then, when the voltage level of V- pin becomes equal or less than the excess current threshold voltage, both protection circuits are released automatically. Resistor for release from excess discharge current is active when excess discharge current or short circuit is detected. While charge and discharge are acceptable for the battery pack, or normal mode, the resistor is inactive.Output delay time for excess discharge current is necessarily set shorter than output delay time for over-discharge. Therefore, if excess discharge current is detected, and at the same time, V DD pin voltage becomes lower than over-discharge detector threshold level, excess discharge current detector is predominant. By disconnecting load from the battery pack, the battery pack is automatically released from excess current state.• VD4/ Excess charge-current detectorWhile charge and discharge are acceptable with the battery pack, VD4 senses V- pin voltage. For example, if the battery pack is charged by an inappropriate charger, excess current flows, then the voltage of V- pin becomes equal or less than excess charge-current detector threshold (Typ. –0.10V). Then, the output of C OUT becomes “L”, and protects against flowing excess current in the circuit by turning off the external Nch MOSFET.Output delay of excess charge current is internally fixed. (Typ. 8ms) Even the voltage level of V- pin becomes equal or lower than excess charge-current detector threshold, if the voltage is higher than the VD4 threshold within the delay time, excess charge-current state is not detected. Output delay time for release from excess charge current is also set internally.VD4 can be released by disconnecting a charger and setting a load.• DS (Delay Shortening) functionWhen the C OUT is "H", the o utput delay time of over-charge, over-discharge, and release from over-discharge can be shorter than those setting values by forcing equal or lower than the delay shortening mode voltage (Typ. -2.0V) to V- pin.R5402N101KD [8] Technical Notes*R1 and C1 stabilize a supply voltage to the R5402. A recommended R1 value is equal or less than 1kΩ. A large value of R1 makes detection voltage shift higher because of the conduction current flown in the R5402.Further, to stabilize the operation of R5402, use the C1 with the value of 0.01µF or more.*R1 and R2 can operate as a current limit against setting cell reverse direction or applying excess charge voltage to the R5402. While small value of R1 and R2 may cause over power dissipation rating of the R5402, therefore a total of “R1+R2” should be 1kΩ or more. Besides, if a large value of R2 is set, release from over-discharge by connecting a charger might not be possible. Recommended R2 value is equal or less than 10kΩ.[9] Timing Diagrams(1) Timing diagram of over-charge voltage and over-charge currentVddV-CoutChargeCurrentDischargeCurrentOver-charge CurrentVdet1 Charge/ Discharge CurrentVrel1(2) Over-discharge, Excess discharge current, Short circuitV DDD OUT VV V-VV V VConnect ChargerCharge /DischargeCurrentCharge CurrentDischarge CurrentExcessOpentV DET2tV V Connect OpenVR5402N101KD- 11/11 -[10] Package Dimensions (SOT23-6)0.15+0.1-0.05Unit :mm[11] Mark Specificationcd : Series Code Name … VC ef : Lot Number (Alphanumeric serial number)。
54AC2525DMQB中文资料
MICROCIRCUIT DATA SHEET
Features
Ideal for signal generation and clock distribution Guaranteed pin to pin and part to part skew Guaranteed 2000V minimum ESD protection 24 mA output drive capability CONTROLLING DOCUMENT: 54AC2525WFQMLV 5962F9217401VDA 54AC2525WRQMLV 5962R9217401VDA
125mV/ns
3
元器件交易网
MV54AC2525-X-RH REV 1A0
MICROCIRCUIT DATA SHEET
Electrical Characteristics
DC PARAMETERS
(The following conditions apply to all the following parameters, unless otherwise specified.) DC: VCC 3.0V to 5.5V, Temp. Range: -55 C to 125 C. NOTE: -55C TEMPERATURE, SUBGROUP 3 IS GUARANTEED BUT NOT TESTED. SYMBOL IIH PARAMETER High level input Current Low level input Current Low level Output Voltage CONDITIONS VCC=5.5V, VM=5.5V NOTES PINNAME MIN MAX 0.1 1.0 -0.1 -1.0 .10 .10 .10 .32 .40 .36 .50 .36 .50 1.65 UNIT uA uA uA uA V V V V V V V V V V V V V V V V V V V V 90 80 nA uA SUBGROUPS 1 2, 3 1 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1 2, 3 1 2, 3 1 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1 2, 3 1 2, 3 1 2, 3 1, 2, 3 1 2, 3
RCLAMP0504F中文资料
e-t
td = IPP/2
5
10
15
20
25
30
Time (µs)
Forward Voltage vs. peak Pulse Current
8
7
6
5
4
3
Waveform
2
Parameters:
tr = 8µs
1
td = 20µs
0
0
1
2
3
4
5
6
Peak Pulse Current - IPP (A)
25
V
3
pF
1.5
pF
© 2008 Semtech Corp.
2
元器件交易网
PROTECTION PRODUCTS Typical Characteristics
Non-Repetitive Peak Pulse Power vs. Pulse Time
IPP = 6A, tp = 8/20μs Any pin to pin 2
VR = 0V, f = 1MHz Any I/O pin to pin 2
V = 0V, f = 1MHz R
Between I/O pins
Minimum 6
Typical
Maximum 5
Units V V
3
μA
15
V
RClamp0504F
Insertion Loss S21 (I/O to I/O)
CH1 S21 LOG 6 dB / REF 0 dB
START. 030 MHz
STOP 3000.000000 MHz
RM-700数字钢琴说明书
Key Features/Benefits…▪88-key stereo, multi-sampled piano for superb tone▪Counterweighted action with escapement and Ivory Feel keyboard for superb touch▪Widescreen Color Touch LCD for quick & easy access and navigation to applications▪SMF and .WAV file playback via USB host port for ensemble playing and sing-along fun▪Audio CD playback with optional USB-CD drive for more ensemble playing and sing-along fun▪Ability to easily record audio from the piano or external sources and create CD’s with the optional CD DriveTarget Market…▪ Adult “Hobbyists”▪Music educators & students▪Schools & houses of worship▪ANYONE who wants to learn, create, play, and record musicDisplay & Preparation…▪Install Roland CD-01A USB CD Drive (have plenty of blank CD-R’s handy)▪PHA II Action Model & Piano Gram Weight▪Flat-screen LCD or Plasma monitor▪ Remote Control▪One Touch Song Sampler Book▪USB Memory Key with Amazing Grace files▪Roland Headphones, Vocal Mic, & Amazing Grace demo CD▪BONUS: Hal Leonard Play-Along Books/Catalog & Educational Titles▪BONUS: iPod or other portable music player with Amazing Grace filesDemo Superb Piano Tone (start with fallboard in half-rest position)…▪88-key Multi-sampled Piano sound from 9’ concert grand…powered by Roland-designed and manufactured RSS chip ▪Play “live” or use Demo by pressing V-LINK and REVERB buttons simultaneously…then touch Piano icon in screen ▪Stereo sample with Panning for truest piano sound…low notes sound from left side…high notes from right side▪WOW FACTOR! Put the headphones on the customer and play DemoDemo Superb Touch…▪Counter-weighted Progressive Hammer Action just as in grand piano…show PHA II Action Model▪Action gets progressively lighter toward the higher range of the piano…demo with gram weights▪Simulated Escapement gives player same feel as a grand piano…have customer feel the “click”▪KEY FEATURE: “Ivory Feel” keyboard simulates ivory and ebony keys and absorbs oil and moisture, giving the player a more secure feel and better control of the keyboard ($10,000+ price point in acoustics for this feature) Demo Touchscreen & Piano Designer (open fallboard now)▪Demo lowering and raising grand lid on screen…then ”take it off” for “concert position”…have customer try it!▪Touch “Piano Designer”…touch “Keyboard…change “Key Touch” to Light…press [Exit]…lower lid to “short prop”▪Press [Exit] button and show ability to save the “newly-designed” piano…Press [Menu]…Touch “Settings”▪Touch arrows to navigate to Page 5/5…Touch “Memory Backup”…do not “Execute”…Press [Exit] twiceDemo Easy Access to Hundreds of Sampled Tones and Music Styles…▪Press [Strings] in Tone section…Demo EX Rich Strings▪Press [Others] in Tone section…touch Guitar icon…Demo EX Acoustic Guitar▪Press [Pop/Rock]…play a little bit of AmericanRock and Gold Disco, referencing Roland V-Drums▪Press [User Program] and explain ability to save favorite tones, styles, combinations, and settings▪Demo “favorite” UPG’s, being sure to include at least one layer from page 1, one new sound from page 2, one split from page 3, and one new music style from page 5...Optional: demo one “EZ Chord” UPG from page 4Demo Built-in Songs, DigiScore, & Slide Shows…▪Press [Song]…Touch “EZ Songs”…choose Twinkle, Twinkle or Mary Had A Little Lamb…press [Digiscore]▪Press [Play] and Demo Tempo control and muting of left or right hand for more enjoyable and effective practice▪Demo Classical Song 1 and note the slide show that includes Mozart’s bio, beautiful scenes from Vienna, and playing tips for the songDemo One Touch Song…▪Press [One Touch Song]…touch “List” and the 8 songs from the One Touch Song SAMPLER BOOK will appear▪Choose a song and press [Exit] to reveal the One Touch screen that shows the structure of the arrangement▪Play through a couple of sections to demo the drum fill and orchestration change as you go from one section to anotherDemo Visual Lesson…▪Press [Menu]…touch “Visual Lesson”…touch “Beginner”…press “arrow” and “OK” to start Mary Had A Little Lamb▪After intro, play along, making a few errors but not too many…when finished, wait for the drum roll and score, then touch “arrow” and press [Next] or [Prev] to navigate to measures where the errors are marked in colorDemo Recording & Playback…▪To show simple one-track recording…press [Rec]…touch “SMF”…play a few notes…press [Stop]…press [Prev]▪Press [DigiScore]…press [Play]…note ability to add up to 15 more tracks and save in internal memory or to USB▪To show audio file playback…load Amazing Grace CD…press [Song]…touch “Audio CD”…touch “Track 1”▪Press [Play]…during playback, press [Right] track to demo Center Cancel…press [Slow] tempo button to reduce tempo up to 75% of original tempo…press [Slow] & [Fast] simultaneously to return to original tempo▪Press [Transpose] and rotate dial or touch keys in screen to instantly change key “on the fly”▪BONUS: If customer has iPod, connect via “Roland Audio Ports” and demo playback, transposition, and Center Cancel (no tempo control) of customer’s song filesDemo Audio Recording & CD Creation…▪Insert USB Key & check Mic volume▪ Select Amazing Grace Track 1 from the CD and press [Right] Track to Center Cancel the vocal▪Press [Rec]…touch “Audio”…touch “Add On”…press [Play] and sing (or have customer sing) a few bars▪Press [Stop]…the “Rename” screen will appear…rename the file and touch “Execute”▪Touch “External Memory” and select the file you just named…now eject the CD and insert a blank CD-R▪Touch “File”...touch “Write to CD”…touch “OK”…then touch “OK” in the next three screens and the CD is finalized See RM-700 Demonstration Guide for Additional Features and Functions。
UNITRODE UC1524 UC2524 UC3524 数据手册
UC1524UC2524UC3524BLOCK DIAGRAMDESCRIPTIONThe UC1524,UC2524and UC3524incorporate on a single monolithic chip all the functions required for the construction of regulating power supplies,in-verters or switching regulators.They can also be used as the control element for high-power-output applications.The UC1524family was designed for switching regulators of either polarity,transformer-coupled dc-to-dc convert-ers,transformerless voltage doublers and polarity converter applications em-ploying fixed-frequency,pulse-width modulation techniques.The dual alternating outputs allow either single-ended or push-pull applications.Each device includes an on-chip reference,error amplifier,programmable oscilla-tor,pulse-steering flip-flop,two uncommitted output transistors,a high-gain comparator,and current-limiting and shut-down circuitry.The UC1524is characterized for operation over the full military temperature range of -55°C to +125°C.The UC2524and UC3524are designed for operation from -25°C to +85°C and 0°to +70°C,respectively.Advanced Regulating Pulse Width ModulatorsFEATURES•Complete PWM Power Control Circuitry•Uncommitted Outputs for Single-ended or Push-pull Applications•Low Standby Current…8mA Typical •Interchangeable with SG1524,SG2524 and SG3524, RespectivelySLUS180D - NOVEMBER 1999 - REVISED AUGUST 2002查询UC1524供应商CONNECTION DIAGRAMABSOLUTE MAXIMUM RATINGS (Note 1)Supply Voltage,V CC (Notes 2 and 3). . . . . . . . . . . . . . . . .40V Collector Output Current. . . . . . . . . . . . . . . . . . . . . . . . .100mA Reference Output Current . . . . . . . . . . . . . . . . . . . . . . . .50mA Current Through C T Terminal. . . . . . . . . . . . . . . . . . . . . .–5mA Power Dissipation at T A = +25°C (Note 4). . . . . . . . . .1000mW Power Dissipation at T C = +25°C (Note 4). . . . . . . . . .2000mW Operating Junction Temperature Range . . . .–55°C to +150°C Storage Temperature Range . . . . . . . . . . . . .–65°C to +150°CNote 1:Over operating free-air temperature range unless oth-erwise noted.Note 2:All voltage values are with respect to the ground termi-nal, pin 8.Note 3:The reference regulator may be bypassed for operationfrom a fixed 5V supply by connecting the V CC and ref-erence output pins both to the supply voltage.In this configuration the maximum supply voltage is 6V .Note 4:Consult packaging section of databook for thermal lim-itations and considerations of package.RECOMMENDED OPERATING CONDITIONSSupply Voltage,V CC . . . . . . . . . . . . . . . . . . . . . . . . . .8V to 40V Reference Output Current. . . . . . . . . . . . . . . . . . . . .0 to 20mA Current through C T Terminal. . . . . . . . . . . . .–0.03mA to –2mA Timing Resistor, R T . . . . . . . . . . . . . . . . . . . . . 1.8k Ωto 100k ΩTiming Capacitor, C T . . . . . . . . . . . . . . . . . . .0.001µF to 0.1µF Operating Ambient Temperature RangeUC1524. . . . . . . . . . . . . . . . . . . . . . . . . . . .–55°C to +125°C UC2524. . . . . . . . . . . . . . . . . . . . . . . . . . . . .–25°C to +85°C UC3524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0°C to +70°CELECTRICAL CHARACTERISTICS:Unless otherwise stated,these specifications apply for T A =–55°C to +125°Cfor the UC1524,–25°C to +85°C for the UC2524,and 0°C to +70°C for the UC3524,V IN =20V,and f =20kHz,T A =T J .PARAMETER TEST CONDITIONS UC1524/UC2524UC3524UNITSMIN MAX MIN MAXReference Section Output Voltage 4.8 5.0 5.2 4.6 5.0 5.4VLine Regulation V IN = 8 to 40V10201030mV Load Regulation I L = 0 to 20mA20502050mV Ripple Rejection f = 120Hz,T J = 25°C6666dB Short Circuit Current Limit V REF = 0,T J = 25°C100100mA Temperature Stability Over Operating Temperature Range 0.310.31%Long Term Stability T J = 125°C, t = 1000 Hrs.2020mV Oscillator SectionMaximum Frequency C T = .001mfd, R T = 2k Ω300300kHz Initial Accuracy R T and C T Constant55%Voltage Stability V IN = 8 to 40V,T J = 25°C11%Temperature Stability Over Operating Temperature Range 55%Output Amplitude Pin 3,T J = 25°C3.5 3.5V Output Pulse Width C T = .01mfd,T J = 25°C 0.50.5µsError Amplifier SectionInput Offset Voltage V CM = 2.5V0.55210mV Input Bias Current V CM = 2.5V 210210µAOpen Loop Voltage Gain 72806080dBCommon Mode Voltage T J = 25°C1.8 3.4 1.8 3.4VELECTRICAL CHARACTERISTICS:Unless otherwise stated,these specifications apply for T A=–55°C to+125°C for the UC1524,–25°C to+85°C for the UC2524,and0°C to+70°C for the UC3524,V IN=20V,and f=20kHz,T A=T J.PARAMETER TEST CONDITIONSUC1524/UC2524UC3524UNITS MIN MAX MIN MAXError Amplifier Section(cont.)Common Mode Rejection Ratio T J= 25°C7070dB Small Signal Bandwidth A V= 0dB,T J= 25°C33MHz Output Voltage T J= 25°C0.5 3.80.5 3.8V Comparator SectionDuty-Cycle% Each Output On045045% Input Threshold Zero Duty-Cycle11VMaximum Duty-Cycle 3.5 3.5V Input Bias Current11µA Current Limiting SectionSense Voltage Pin 9 = 2V with Error AmplifierSet for Maximum Out,T J= 25°C190200210180200220mV Sense Voltage T.C.0.20.2mV/°C Common Mode Voltage T J= –55°C to 85°Cfor the –1V to 1V Limit–1+1–1+1VT J= 125°C–0.3+1V Output Section(Each Output)Collector-Emitter Voltage4040V Collector Leakage Current V CE= 40V0.1500.150µA Saturation Voltage I C= 50mA1212V Emitter Output Voltage V IN= 20V17181718V Rise Time R C= 2kΩ,T J= 25°C0.20.2µs Fall Time R C= 2kΩ,T J= 25°C0.10.1µs Total Standby Current (Note)V IN= 40V810810mAThe UC1524is a fixed-frequency pulse-width-modulation voltage regulator control circuit.The regulator operates at a frequency that is programmed by one timing resistor (R T),and one timing capacitor(C T),R T establishes a constant charging current for C T.This results in a linear voltage ramp at C T,which is fed to the comparator provid-ing linear control of the output pulse width by the error amplifier.The UC1524contains an on-board5V regulator that serves as a reference as well as powering the UC1524’s internal control circuitry and is also useful in supplying external support functions.This reference volt-age is lowered externally by a resistor divider to provide a reference within the common-mode range of the error amplifier or an external reference may be used.The power supply output is sensed by a second resistor di-vider network to generate a feedback signal to the error amplifier.The amplifier output voltage is then compared to the linear voltage ramp at C T.The resulting modulated pulse out of the high-gain comparator is then steered to the appropriate output pass transistor(Q1or Q2)by the pulse-steering flip-flop,which is synchronously toggled by the oscillator output.The oscillator output pulse also serves as a blanking pulse to assure both outputs are never on simultaneously during the transition times.The width of the blanking pulse is controlled by the valve of C T.The outputs may be applied in a push-pull configura-tion in which their frequency is half that of the base oscil-lator,or paralleled for single-ended applications in which the frequency is equal to that of the oscillator.The output of the error amplifier shares a common input to the com-parator with the current limiting and shutdown circuitry and can be overridden by signals from either of these in-puts.This common point is also available externally and may be employed to control the gain of,or to compen-sate,the error amplifier or to provide additional control to the regulator.PRINCIPLES OF OPERATIONfrequency.TYPICAL CHARACTERISTICSOscillatorThe oscillator controls the frequency of the UC1524and is programmed by R T and C T according to the approximate formula:f R C T T ′1.18where R T is in k ΩC T is in mF f is in kHzPractical values of C T fall between 0.001mF and 0.1mF .Practical values of R T fall between 1.8k Ωand 100k Ω.This results in a frequency range typically from 120Hz to 500kHz.BlankingThe output pulse of the oscillator is used as a blanking pulse at the output.This pulse width is controlled by the value of C T .If small values of C T are required for fre-quency control,the oscillator output pulse width may still be increased by applying a shunt capacitance of up to 100pF from pin 3to ground.If still greater dead-time is re-quired,it should be accomplished by limiting the maxi-mum duty cycle by clamping the output of the erroramplifier.This can easily be done with the circuit in Fig-ure 1:Synchronous OperationWhen an external clock is desired,a clock pulse of ap-proximately 3V can be applied directly to the oscillator output terminal.The impedance to ground at this point is approximately 2k Ω.In this configuration R T C T must be selected for a clock period slightly greater than that of the external clock.If two or more UC1524regulators are to operated synchro-nously ,all oscillator output terminals should be tied to-gether,all C T terminals connected to single timing capacitor,and the timing resistor connected to a single R T ,terminal.The other R T terminals can be left open or shorted to V REF .Minimum lead lengths should be used between the C T ter-minals.APPLICATION INFORMATIONV REF COMP5kGND Figure 1.UNITRODE CORPORA TION7 CONTINENT AL BLVD.•MERRIMACK, NH 03054 TEL.(603) 424-2410FAX (603) 424-3460PACKAGING INFORMATIONOrderable DeviceStatus (1)Package Type Package DrawingPins Package Qty Eco Plan (2)Lead/Ball FinishMSL Peak Temp (3)UC1524J OBSOLETE CDIP J 16None Call TI Call TI UC1524J/80937OBSOLETE CDIP J 16None Call TI Call TI UC1524J883B OBSOLETE CDIP J 16None Call TI Call TIUC2524DW ACTIVE SOIC DW 1640None CU NIPDAU Level-2-220C-1YEAR UC2524DWTR ACTIVE SOIC DW 162000None CU NIPDAU Level-2-220C-1YEAR UC2524J OBSOLETE CDIP J 16None Call TI Call TIUC2524N ACTIVE PDIP N 1625None CU SNPB Level-NA-NA-NA UC3524D ACTIVE SOIC D 1640None CU NIPDAU Level-1-220C-UNLIM UC3524DTR ACTIVE SOIC D 162500None CU NIPDAU Level-1-220C-UNLIM UC3524DW ACTIVE SOIC DW 1640None CU NIPDAU Level-2-220C-1YEAR UC3524DWTR ACTIVE SOIC DW 162000None CU NIPDAU Level-2-220C-1YEAR UC3524J OBSOLETE CDIP J 16None Call TI Call TIUC3524NACTIVEPDIPN1625NoneCU SNPBLevel-NA-NA-NA(1)The marketing status values are defined as follows:ACTIVE:Product device recommended for new designs.LIFEBUY:TI has announced that the device will be discontinued,and a lifetime-buy period is in effect.NRND:Not recommended for new designs.Device is in production to support existing customers,but TI does not recommend using this part in a new design.PREVIEW:Device has been announced but is not in production.Samples may or may not be available.OBSOLETE:TI has discontinued the production of the device.(2)Eco Plan -Maynot be currently available -please check /productcontent for the latest availability information and additional product content details.None:Not yet available Lead (Pb-Free).Pb-Free (RoHS):TI's terms "Lead-Free"or "Pb-Free"mean semiconductor products that are compatible with the current RoHS requirements for all 6substances,including the requirement that lead not exceed 0.1%by weight in homogeneous materials.Where designed to be soldered at high temperatures,TI Pb-Free products are suitable for use in specified lead-free processes.Green (RoHS &no Sb/Br):TI defines "Green"to mean "Pb-Free"and in addition,uses package materials that do not contain halogens,including bromine (Br)or antimony (Sb)above 0.1%of total product weight.(3)MSL,Peak Temp.--The Moisture Sensitivity Level rating according to the JEDECindustry standard classifications,and peak solder temperature.Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided.TI bases its knowledge and belief on information provided by third parties,and makes no representation or warranty as to the accuracy of such information.Efforts are underway to better integrate information from third parties.TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.TI and TI suppliers consider certain information to be proprietary,and thus CAS numbers and other limited information may not be available for release.In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s)at issue in this document sold by TI to Customer on an annual basis.PACKAGE OPTION ADDENDUM8-Mar-2005Addendum-Page 1IMPORTANT NOTICETexas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. T esting and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. T o minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation.Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions:Products ApplicationsAmplifiers Audio /audioData Converters Automotive /automotiveDSP Broadband /broadbandInterface Digital Control /digitalcontrolLogic Military /militaryPower Mgmt Optical Networking /opticalnetwork Microcontrollers Security /securityTelephony /telephonyVideo & Imaging /videoWireless /wirelessMailing Address:Texas InstrumentsPost Office Box 655303 Dallas, Texas 75265Copyright 2005, Texas Instruments Incorporated。
SM5024资料
SM5024 seriesMiniature-package Crystal Oscillator Module ICsOVERVIEWThe SM5024 series are fundamental crystal oscillator module ICs. They feature an oscillator circuit with built-in capacitors with excellent frequency response and an output buffer with high output drive capability. They are available in miniature 6-pin packages, making them ideal as DIP-type crystal oscillators.FEATURESIOperating supply voltage range •3V operation: 2.7 to 3.6V •5V operation: 4.5 to 5.5VIUp to 30MHz operating frequency range (fundamental oscillation)I –40 to 85 ° C operating temperature range I Oscillator capacitors C G , C D built-in I Feedback resistor R f built-inIf O , f O /2, f O /4, f O /8 output frequency, determined by internal connection IOutput drive capability •8mA (V DD = 2.7V)•16mA (V DD = 4.5V)IOutput three-state function built-inHigh impedance outputs in standby mode I CMOS output duty level (1/2VDD) I Molybdenum-gate CMOS process IPackage: SOT23-6 (SM5024 ××× H)APPLICATIONSIDIP-type crystal oscillator modulesPACKAGE DIMENSIONS(Unit: mm)SERIES CONFIGURATIONORDERING INFORMATIONVersionOperating Supply voltage range [V]Recommended operating frequency range 1 [MHz]1. The recommended operating frequency is a yardstick value derived from the crystal used for NPC characteristics authentication. However, the oscilla-tor frequency band is not guaranteed. Specifically, the characteristics can vary greatly due to crystal characteristics and mounting conditions, so the oscillation characteristics of components must be carefully evaluated.Built-in capacitance[pF]Outputduty levelOutput frequency INHN inputlevelStandby mode C G C D Oscillatorstop functionOutput stateSM5024AL1H 2.7 to 5.54 to 30810CMOSf OTTLYesHi-ZSM5024AL2H f O /2SM5024AL3H f O /4SM5024AL4Hf O /8Device Package SM5024 ×××HSOT23-6SM5024 seriesPINOUT(Top view)BLOCK DIAGRAMNotes.The SM5024 series reduce crystal current by limiting driving current of oscillating-stage inverter and inhibiting oscillating amplitude. Depending on the characteristics of using crystal or the mounting condition, they may not oscillate normally. Please evaluate the oscillation start-up characteris-tics adequately with your actual device. When this device is used for buffer application, please pay attention to input amplitude to the XT pin. If it’s low input amplitude, the SM5024 series may not operate normally.SM5024 seriesFUNCTIONAL DESCRIPTIONStandby FunctionWhen INHN goes LOW, the oscillator stops and the oscillator output on Q becomes high impedance.Current consumption and Output waveform with NPC’s standard crystalINHN QOscillator HIGH (or open)Any f O , f O /2, f O /4, or fO/8 output frequencyNormal operationLOWHigh impedanceStoppedf [MHz]R [Ω]L [mH]Ca [fF]Cb [pF]305.262.821.002.68SM5024 seriesSPECIFICATIONSAbsolute Maximum RatingsV SS = 0VParameter Symbol Condition Rating Unit Supply voltage range V DD−0.5 to +7.0V Input voltage range V IN−0.5 to V DD + 0.5V Output voltage range V OUT−0.5 to V DD + 0.5V Operating temperature range T opr−40 to +85°C Storage temperature range T STG−55 to +125°C Output current I OUT20mA Power dissipation P D250mWRecommended Operating Conditions3V operationV SS = 0V, f ≤ 30MHz, C L≤ 15pF unless otherwise noted.Parameter Symbol Condition Rating Unit Operating supply voltage V DD 2.7– 3.6V Input voltage V IN V SS–V DD V Operating temperature T OPR−20–+80°C 5V operationV SS = 0V, f ≤ 30MHz, C L≤ 50pF unless otherwise notedParameter Symbol Condition Rating Unit Operating supply voltage V DD 4.5– 5.5V Input voltage V IN V SS–V DD V Operating temperature T OPR−40–+85°CSM5024 seriesElectrical Characteristics3V operationV SS = 0V , recommended operating conditions unless otherwise noted.5V operationV SS = 0V , recommended operating conditions unless otherwise noted.Parameter Symbol ConditionRatingUnit min typ max HIGH-level output voltage V OH Q: Measurement cct 1, V DD = 2.7V, I OH = 8mA 2.1 2.4–V LOW-level output voltage V OL Q: Measurement cct 2, V DD = 2.7V, I OL = 8mA –0.30.5V HIGH-level input voltage V IH INHN 2.0––V LOW-level input voltage V IL INHN––0.5V Output leakage currentI ZQ: Measurement cct 2, INHN = LOW, V DD = 3.6VV OH = V DD ––10µA V OL = V SS ––10µA Current consumptionI DD1Measurement cct 3, load cct 1, INHN = open, C L = 15pF , f = 30MHzSM5024AL1H–48mA SM5024AL2H – 2.55mA SM5024AL3H –24mA SM5024AL4H– 1.53mA INHN pull-up resistance R UP Measurement cct 425100250k Ω Feedback resistance R f Measurement cct 52006001000k Ω Built-in capacitanceC G Design value. A monitor pattern on a wafer is tested.7.4488.56pF C D9.31010.7pFParameter Symbol ConditionRatingUnit min typ max HIGH-level output voltage V OH Q: Measurement cct 1, V DD = 4.5V, I OH = 16mA 3.9 4.2–V LOW-level output voltage V OL Q: Measurement cct 2, V DD = 4.5V, I OL = 16mA –0.30.5V HIGH-level input voltage V IH INHN 2.0––V LOW-level input voltage V IL INHN––0.8V Output leakage currentI ZQ: Measurement cct 2, INHN = LOW, V DD = 5.5VV OH = V DD ––10µA V OL = V SS ––10µA Current consumptionI DD2Measurement cct 3, load cct 1, INHN = open, C L = 50pF , f = 30MHzSM5024AL1H–1326mA SM5024AL2H –714mA SM5024AL3H –48mA SM5024AL4H–36mA INHN pull-up resistance R UP Measurement cct 425100250k Ω Feedback resistance R f Measurement cct 52006001000kΩBuilt-in capacitanceC G Design value. A monitor pattern on a wafer is tested.7.4488.56pF C D9.31010.7pFSwitching Characteristics3V operationV DD = 2.7 to 3.6V , V SS = 0V , Ta = −20 to +80°C unless otherwise noted.5V operationV DD = 4.5 to 5.5V , V SS = 0V , Ta = −40 to +85°C unless otherwise noted.Parameter Symbol ConditionRatingUnit min typ max Output rise time t r1Measurement cct 6, load cct 1, 0.1V DD to 0.9V DD , C L = 15pF –510ns Output fall time t f1Measurement cct 6, load cct 1, 0.9V DD to 0.1V DD , C L = 15pF –510ns Output duty cycle 11. The duty cycle characteristic is checked the sample chips of each production lot.Duty1Measurement cct 6, load cct 1, V DD = 3.0V, Ta = 25°C, C L = 15pF , f ≤ 30MHz45–55%Output disable delay time 22. Oscillator stop function is built-in. When INHN goes LOW, normal output stops. When INHN goes HIGH, normal output is not resumed until after the oscillator start-up time has elapsed.t PLZ Measurement cct 6, load cct 1, V DD = 3.0V, Ta = 25°C, C L = 15pF––100ns Output enable delay time 2t PZL––100nsParameterSymbol ConditionRatingUnitmin typ max Output rise time t r1Measurement cct 6, load cct 1, 0.1V DD to 0.9V DDC L = 15pF – 2.55nst r2C L = 50pF –510Output fall time t f1Measurement cct 6, load cct 1, 0.9V DD to 0.1V DDC L = 15pF – 2.55nst f2C L = 50pF–510Output duty cycle 11. The duty cycle characteristic is checked the sample chips of each production lot.Duty2Measurement cct 6, load cct 1, V DD = 5.0V, Ta = 25°C, C L = 50pF , f ≤ 30MHz45–55%Output disable delay time 22. Oscillator stop function is built-in. When INHN goes LOW, normal output stops. When INHN goes HIGH, normal output is not resumed until after the oscillator start-up time has elapsed.t PLZ Measurement cct 6, load cct 1, V DD = 5.0V, Ta = 25°C, C L = 15pF––100ns Output enable delay time 2t PZL––100nsMEASUREMENT CIRCUITSMeasurement cct 12.0Vp-p, 10MHz sine wave input signal (3V operation)3.5Vp-p, 10MHz sine wave input signal (5V operation)C1: 0.001µF R1: 50ΩR2: 263Ω (3V operation)244Ω (5V operation)Measurement cct 2Measurement cct 32.0Vp-p, 30MHz sine wave input signal (3V operation)3.5Vp-p, 30MHz sine wave input signal (5V operation)C1: 0.001µF R1: 50ΩMeasurement cct 4Measurement cct 5Measurement cct 6Measurement cct 7R1: 50ΩLoad cct 1Switching Time Measurement W aveformOutput duty level, t r , t fOutput duty cycleOutput Enable/Disable DelayWhen the device is in standby, the oscillator stops. When standby is released, the oscillator starts and stable oscillator output occurs after a short delay.C L = 15pF: t r1, t f1, Duty1, I DD1C L = 50pF: t r2, t f2, Duty2, I DD2Q outputcapacitance)Q outputDUTY measurement voltage (0.5VDD )DUTY measurement voltage (0.5V DD )Q outputW / T 100 (%)Q outputINHNINHN input waveform t r = t f 10nsNC0303BE2004.10。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
F0164-A
V REG.-Nr. 40003144, Z E214025
Contact data RM5RM6
Contact configuration 2 NO 3 NO
Contact set single contact
Type of interruption full disconnection
Rated current16A10A
Rated voltage / max.switching voltage AC 400/440VAC230/400VAC
Maximum breaking capacity AC 6000VA3800VA
Limiting making capacity, max 20 ms25A25A
Contact material AgNi90/10, AgCdO
Contact gap3mm
Mechanical endurance 20x106cycles
Rated frequency of operation with / without load 16/100 min-1
Contact ratings
Type Load Cycles
RM5.16A, 415VAC, UL100x103
RM5016A, 230/400VAC, cosϕ=1, 35°C, VDE100x103
RM5.16A, 250VAC, general purpose, UL30x103
RM5010A, 48VDC, 70°C, VDE, UL30x103
RM6.5A, 400VAC, resistive, UL100x103
RM6010A, 230/400VAC, cosϕ=1, 35°C, VDE100x103
RM6.10A, 300VAC, resistive, UL100x103
RM6.10A, 250VAC, general purpose, UL30x103
Coil data
Rated coil voltage range DC coil 6...220VDC
AC coil 6...400VAC
Coil power DC coil 1.6W
AC coil 2.8VA
Operative range 1
Coil versions,DC-coil
STD LED PD*LED+voltage voltage voltage resistance power
bipolar PD*VDC VDC VDC Ohm W
006L060A6LA66 4.50.624+10% 1.5
012L120B2LB2129.0 1.286+10% 1.7
024L240C4LC42418.0 2.4345+10%1.7
048L480E8LE84836.0 4.81340+10% 1.7
060L600G0LG06045.0 6.02200+10% 1.6
110M101B0MB011082.511.07300+10% 1.7
221N212C1NC1220165.022.030000+15% 1.6
*) Protection diode PD; standard polarity: +A1/-A2
PCB layout / terminal assignment
Bottom view on pins
3 NO contacts
2 NO contacts
S0269-AC
S0269-AE
Coil versions,AC-coil 50/60Hz Coil code Rated Operate Release Coil Rated coil
STD LED voltage
voltage voltage resistance power 50/60Hz 50/60Hz 50/60Hz
VAC VAC VAC Ohm VA
506R066 4.8 2.4 4.7+10% 2.86/2.36512R12129.6 4.819.5+10% 2.71/2.27524R242419.29.680+10% 2.62/2.00548R484838.419.2320+10% 2.60/2.17560R606048.024.0500+10% 2.62/2.20615S1511592.046.01850+10% 2.65/2.22
730T30230184.092.07500+10% 2.69/2.26
900V00400320.0160.023500+15% 2.61/2.20All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
Dielectric strength coil-contact circuit
2500V rms open contact circuit
2500V rms adjacent contact circuits
2500V rms adjacent contact circuits
W 6.1/7.3mm
Material group of insulation parts W IIIa Insulation to IEC 60664-1
Type of insulation coil-contact circuit
basic open contact circuit
basic adjacent contact circuits
basic Rated insulation voltage
250/400V 1)
Pollution degree 3Rated voltage system 240/400V Overvoltage category III 1)
Other data
RoHS - Directive 2002/95/EC compliant as per product date code 0415Ambient temperature range DC coil -45...+60°C
AC coil -45...+50°C
Operate- / release time 15/10ms Bounce time NO / NC contact 4ms Vibration resistance (function) NO / NC contact 12g, 30...150Hz Category of protection RTI - dust protected Mounting position versions with test button not to be
mounted with button on top
Resistance to soldering heat 270°C /10s Relay weight 81g Packaging unit 10/25pcs
Accessories
For details see datasheet
Accessories Power Relay RM
Dimensions
Plain cover, plug-in version
PCB version
Cover with mounting brackets, 6.3mm quick connect (4.8mm available)
Cover with DIN-snap-on attachement (6.3mm quick connect only)
horizontal vertical
S0298-BF S0298-BJ
S0298-BI S0298-BH。