意大利NBC称重传感器意大利NBC有限公司在意大利成立,是一个基于应变式称重传感器,数字指标,吊秤称重系统,自成立以来,NBC称重传感器的产品远销38个国家,在多个国家设立了分支机构或办事处,生产基地遍布美洲、东欧、中国等地;并在中国设立了广州南创传感器事业部,可为用户的实验和生产提供最佳的服务与解决方案。

1.悬臂梁称重传感器Mod AH:5kg,10kg,15kg,20kg,25kg,30kg,50kg,75kg,100kgMod BH:50kg,75kg,100kg,150kgMod CH:150kg,300kg,500kg,750kgMod CD:100kg,150kg,200kg,250kg,300kg,400kgMod CF:75kg,100kg,200kg,300kgMod CN/L:7.5kg,15kg,30kg,50kg,60kg,75kgMod CN/H:60kg,120kg,200kg,250kg,300kgMod FT:100kg,200kg,300kg,350kg,500kgMod FB:250kg,500kg,1000kg,1760kg,2500kg,5000kgMod FH:500kg,1000kg,1760kg,2500kg,3000kg,5000kg,10000kg,15000kgMod FX:1t,2t,3t,5t,10t2.波纹管称重传感器Mod GX:10kg,15kg,20kg,25kg,30kg,50kg,75kg,100kg,150kg,200kg,250kgModGL:10kg,15kg,20kg,25kg,50kg,75kg,100kg,150kg,200kg,250kg,300kg,500kg,750kg3.S型称重传感器Mod SU:2kg,5kg,10kg,20kg,50kgMod SU Radio:6300kgMod ST1:100-1000kg,2000-2500kgMod ST2:5000kg,7500kg,10000kg,15000kg,20000kgModSX:150kg,200kg,300kg,500kg,1000kg,2000kg,2500kg,3000kg,5000kg,7500kg,10000 kg,15000kgMod PI:0.5-100t3.轮辐式及柱式称重传感器ModCM:250kg,500kg,1000kg,2500kg,5000kg,7500kg,10000kg,15000kg,20000kg,25000k g,35000kg,50000kgMod CO:5t,10t,15t,20t,25tMod TA:0.5t,1t,2t,5t,10t,20t,30t,50t,60tMod KX:10t,25t,30t,50tMod CT:30t,60t,100t,200t,300t,500tMod EP:25kg,50kg,150kg,150-300kg,600kgMod EC:15kg,25kg,50kg,100kg,200kg意大利NBC图片:。

NA4称重传感器Mavin

NA4称重传感器Mavin

NA4
称重传感器Array
兰瑟电子(台湾mavin)
传感器数量怎么选择:传感器数量的选择是根据电子衡器的用途、秤体需要支撑的点数(支撑点数应根据使秤体几何重心和实际重心重合的原则而确定)而定。

一般来说,秤体有几个
支撑点就选用几只传感器,但是对于一些特殊的秤体如电子吊钩秤就只能采用一个传感器,
一些机电结合秤就应根据实际情况来确定选用传感器的个数。

Array
NA4称重传感器相关量程:
NA4-40KG称重传感器
NA4-60kg称重传感器
NA4-100kg称重传感器
NA4-200kg称重传感器NA4-250kg称重传感器NA4-300kg称重传感器NA4-500kg称重传感器NA4-800kg称重传感器。

微乃电子微波水位传感器M FMR230 231、FMR240 244 245、FMR250操作手册说

微乃电子微波水位传感器M FMR230 231、FMR240 244 245、FMR250操作手册说

SD00327F/00/EN/13.1071125885Functional Safety ManualMicropilot MFMR230/231, FMR240/244/245, FMR250Level-Radarwith 4 to 20 mA Output SignalApplicationOperating minimum (e.g. dry run protection) andmaximum (e.g. overfill protection) detection of powdery to granular bulk solids and all types of liquids in systems to satisfy particular safety systems requirements as per IEC 61508/IEC 61511.The measuring device fulfils the requirements concerning•Functional safety as per IEC 61508/IEC 61511•Explosion protection (depending on the version)•Electromagnetic compatibility as per EN 61326 and NAMUR recommendation NE 21•Electrical safety as per IEC/EN 61010-1Your benefits•Used for level monitoring (MIN, MAX) up to SIL 2–Independently assessed (Functional Assessment) by as per IEC 61508/IEC 61511•Permanent self-monitoring •Continuous measurement•Non-contact measurement: measurement is virtually independent of product properties •Easy commissioningMicropilot M Table of contentsSIL Declaration of Conformity. . . . . . . . . . . . . . . . . . .3Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Structure of the measuring system. . . . . . . . . . . . . . . .4System components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Description of use as a protective system . . . . . . . . . . . . . . . . . . . . 5Permitted device types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Supplementary device documentation . . . . . . . . . . . . . . . . . . . . . . 7Description of the safety requirements andboundary conditions . . . . . . . . . . . . . . . . . . . . . . . . . .8Safety function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Restrictions for use in safety-related applications . . . . . . . . . . . . . . 8Functional safety indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Behavior of device during operation and in case of error . . . . . . . 11Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Proof-test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Proof-test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Process for proof-testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Repairs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Commissioning or proof test protocol . . . . . . . . . . . . . . . . . . . . . 17Exida Management Summary . . . . . . . . . . . . . . . . . .182Endress+HauserMicropilot MEndress+Hauser 3SIL Declaration of ConformitySIL_08006a_deMicropilot M4Endress+HauserIntroduction!Note!General information on functional safety (SIL) is available at:/SIL (German) or /SIL (English) and in Competence Brochure CP002Z "Functional Safety in the Process Industry - Risk Reduction with Safety Instrumented Systems".Structure of the measuring systemSystem componentsThe measuring system's devices are displayed in the following diagram (example).An analog signal (4 to 20 mA) in proportion to the level is generated in the transmitter. This is sent to adownstream logic unit (e.g. PLC, limit signal transmitter, etc.) where it is monitored to determine whether it is below or above a specified limit value.For fault monitoring, the logic unit must recognize both HI-alarms (≥ 21.0 mA) and LO-alarms (≤ 3.6 mA).Micropilot MEndress+Hauser 5Description of use as a protective systemThe Micropilot M is a "downward-looking" measuring system that functions according to the ToF method (ToF = Time of Flight). The distance from the reference point (process connection of the measuring device) to the product surface is measured. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system.Typical measuring arrangement:!Note!Correct installation is a prerequisite for safe operation of the device.Permitted device typesThe details pertaining to functional safety in this manual relate to the device versions listed below and are valid as of the specified software and hardware version. Unless otherwise specified, all subsequent versions can also be used for safety instrumented systems.A modification process according to IEC 61508 is applied for device changes.Valid device versions for safety-related use:Micropilot M FMR230, FMR244FeatureDesignation Version 010Approval all 020Antennaall 030Antenna Seal; Temperature all 040Process Connection all 050Output; Operation A, B, K 060Housing all 070Cable Entry all 080Additional OptionallValid software version: FMR230: as of 01.04.00; FMR244: as of 01.05.00Valid hardware version (electronics): as of delivery date January 2010Micropilot MMicropilot M FMR231Feature Designation Version010Approval all020Antenna; Inactive Length all030Process Connection all040Output; Operation A, B, K050Housing all060Cable Entry all070Gas-Tight Feed Through all080Additional Option allValid software version: FMR231: as of 01.04.00Valid hardware version (electronics): as of delivery date January 2010Micropilot M FMR240, FMR250Feature Designation Version010Approval all020Antenna all030Antenna Seal; Temperature all040Antenna Extension all050Process Connection all060Output; Operation A, B, K070Housing all080Cable Entry all090Additional Option allValid software version: FMR240, FMR250: as of 01.05.00Valid hardware version (electronics): as of delivery date January 2010Micropilot M FMR245Feature Designation Version010Approval all020Antenna all030Process Connection all040Output; Operation A, B, K050Housing all060Cable Entry all070Additional Option allValid software version: FMR245: as of 01.05.00Valid hardware version (electronics): as of delivery date January 20106Endress+HauserMicropilot MEndress+Hauser 7Supplementary device documentationDocumentationContentsCommentTechnical InformationTI00345F/00 (FMR23x, FMR24x)TI00390F/00 (FMR250)–Technical data–Instructions on accessories –The documentation is available on the Internet.→ .Operating Instructions (HART)BA00218F/00 (FMR230)BA00219F/00 (FMR231)BA00220F/00 (FMR240)BA00248F/00 (FMR244)BA00251F/00 (FMR245)BA00284F/00 (FMR250)–Identification –Installation –Wiring –Operation–Commissioning –Maintenance –Accessories –Troubleshooting –Technical data –Appendix–The documentation is supplied with the device.–The documentation is also available on the Internet.→ .Operating Instructions (Device Functions)BA00221F/00 (FMR23x)BA00291F/00 (FMR24x, FMR250)–Instructions on use–Micropilot M function menu –Function groups ...–...–Envelope curve –Troubleshooting–Function menu index–The documentation is available on the Internet.→ .Safety instructions depending on the selected version "Approval"–Safety, installation and operating instructions for devices, which are suitable for use in potentially explosive atmospheres or as overfill protection (WHG, German Water Resources Act).Additional safety instructions(XA, XB, XC, ZE, ZD) are supplied with certified device versions.Please refer to the nameplate for the relevant safety instructions.Micropilot M8Endress+HauserDescription of the safety requirements and boundary conditionsSafety functionThe mandatory settings and safety function data emanate from the descriptions from →ä11.The measuring system's reaction time is ≤ 5 s.!Note!MTTR is set at 8 hours.Safety-related signal:The Micropilot M's safety-related signal is the 4 to 20 mA analog output signal. All safety measures refer to this signal exclusively.The Micropilot M additionally communicates effectively via HART and contains all HART features with additional device information.The safety-related output signal is fed to a downstream logic unit, e.g. a programmable logic controller or a limit signal transmitter where it is monitored for the following:–Overshooting and/or undershooting a specified level limit.–The occurrence of a fault, e.g. error current (≤ 3.6 mA, ≥ 21.0 mA, interruption or short-circuit of the signal line).Restrictions for use in safety-related applicationsThe measuring system must be used correctly for the specific application, taking into account the medium properties and ambient conditions. Carefully follow instructions pertaining to critical process situations and installation conditions from the Operating Instructions.The specifications from the Operating Instructions (→ä7, "Supplementary device documentation") must not be exceeded.The following restriction also applies to safety-related use:–The accuracy of the 4 to 20 mA safety-related output signal is ± 10%.Micropilot MFunctional safety indicators The following tables show specific indicators for functional safety.Characteristic as per IEC 61508FMR23x with 4 to 20 mA outputSafety functions MIN MAXSIL2HFT0Device type BMode of operation Low demand modeSFF 67 % 74 %MTTR8 hRecommended time interval for proof-testing T1 1 yearλsd *2 392 FIT 87 FITλsu *2951 FIT1125 FITλdd *2541 FIT846 FITλdu *2916 FIT710 FITλtot *32800 FIT2768 FITPFD avg for T1 = 1 year *14,01 × 10-33,11 × 10-3PFD avg for T1 = 1 year *54,75 × 10-33,69 × 10-3MTBF *335 yearsSystem reaction time *4≤ 5 s*1 PFD avg*2 According to Siemens SN29500.*3 According to Siemens SN29500, including faults outside the safety function.*4 Step response time as per DIN EN 61298-2.*5 Calculated, with MTTR = 24 h, lifetime (LT) = 10 years and proof test coverage (PTC) = 98 %,Proof-test intervalEndress+Hauser9Micropilot MCharacteristic as per IEC 61508FMR24x, FMR250 with 4...20 mA outputSafety functions MIN MAXSIL2HFT0Device type BMode of operation Low demand modeSFF 68 % 75 %MTTR8 hRecommended time interval for proof-testing T1 1 yearλsd *2 356 FIT 99 FITλsu *21031 FIT1207 FITλdd *2621 FIT878 FITλdu *2903 FIT697 FITλtot *32911 FIT2881 FITPFD avg for T1 = 1 year *13,96 × 10-33,05 × 10-3PFD avg for T1 = 1 year *54,68 × 10-33,62 × 10-3MTBF *335 yearsSystem reaction time *4≤ 5 s*1 PFD avg*2 According to Siemens SN29500.*3 According to Siemens SN29500, including faults outside the safety function.*4 Step response time as per DIN EN 61298-2.*5 Calculated, with MTTR = 24 h, lifetime (LT) = 10 years and proof test coverage (PTC) = 98 %,Proof-test interval10Endress+HauserDangerous undetected failures in this scenario:An incorrect output signal that deviates from the real measured value by more than 10%, but is still in the range of 4 to 20 mA, is considered a dangerous, undetected failure.Useful lifetime of electrical components:The established failure rates of electrical components apply within the useful lifetime as per IEC 61508:2000, section 7.4.7.4. note 3.Behavior of device during operation and in case of error Behavior of device during power-upThe safe 4 to 20 mA output signal is available after 17 s after the device is switched on or when the voltage returns.Device response in the event of alarms or warningsError currentIn the event of an alarm, the output current can be configured to a value of ≤ 3.6 mA or ≥ 21.0 mA.In some cases (e.g. failure of power supply, a cable open circuit and faults in the current output itself, where the error current ≥ 21.0 mA cannot be set), output currents ≤ 3.6 mA irrespective of the configured error current can occur.For alarm monitoring, the logic unit must therefore be able to recognize both HI-alarms (≥ 21.0 mA) and LO-alarms (≤ 3.6 mA).Alarm and warning messagesAdditional information is available in the form of fault codes on the alarm and warning messages output.Installation Installation, wiring and commissioningInstallation, wiring and commissioning of the device is described in the accompanying Operating Instructions(→ä7, "Supplementary device documentation").OrientationThe permitted orientations of the device are described in the Operating Instructions.Operation Calibration of the measuring pointCalibration of the measuring point is described in the Operating Instructions.The method of device configuration!Note!Altered settings (display/FieldCare) in the "extended calibr." function group (Pos. 05) such as "offset" or"curr.turn down" (Pos. 063) in the "output" function group have an effect on the output signal.This must be taken into account when calculating the response height (see relevant Operating Instructions).We recommend that you check that the behavior of the current signal matches the expected behavior by meansof level simulation (correctness of configuration).Configuration schemata/basic calibrationThe parameters are safety-oriented with the "WHG" setting in 018 (→ information in the following table).As an alternative to activating the "WHG" setting, it is also possible to make the safety-oriented setting manually. In doing so, please observe the information in the table below.!Note!The parameters in italics are located on the service level, which can be opened with the code "300".FieldCare / Display - plain text displayDisplay VU331 Position Media type (only FMR24x, FMR250 (software version 01.05.00))001↓Tank shape *1 (FMR23x, FMR24x) or Bin type (FMR250)002↓Medium property003↓Process conditions004↓Empty calibration E005↓Full calibration F006↓Pipe diameter (for bypass / stilling well)007↓MappingSee Operating Instructions ↓Further settings: function group 05See Operating Instructions ↓Overfill protection WHG018↓On-site locking: 3 keys on the VU331 displayYes *1 For FMR 240 with wave guide antenna, stilling well must always be selected as tank shape.FieldCare /Display - plain text display Value/parameterDisplay VU331CommentSafety settings Output on ALARM Max. 110 %, 22 mA 010Parameter must be configured in this way Output echo loss ALARM 012Parameter must be configured in this way Delay time1 s014→ Note 1In safety distance SD self holding016→ Note 3!Note! 1.This parameter determines the reaction time of the device in the event of echo loss; a setting of less than 30 s is recommended.2.This parameter determines the reaction time of the device; deviating settings are possible.In case of changes in "process cond." (004) it is automatically adjusted. The corresponding reaction time is indicated in the documentation BA.3.This parameter can be selected differently, depending on the application.A measuring condition (echo) which results in an ALARM in the "Safety distance SD" area can be reset or deleted by–confirming the ALARM in Pos. 017 locally by means of the VU331 LCD display;–confirming the alarm via the communication protocol (HART) (FieldCare: "ackn. alarm" under safety settings).FieldCare /Display - plain text display Value/parameterDisplay VU331CommentFiltering/averaging/delay Envelope statistics up 20D23→ Note 2Envelope statistics down 20D24→ Note 2MAM filter length 50D11→ Note 2MAM filter border 10D12→ Note 2Output damping 0058→ Note 2Echo detection FEF edge (nur bei MIN)00D56Parameter must be configured in this way FAC mode FMC rising 0D99Parameter must be configured in this way FAC adder6 dB 0D35Parameter must be configured in this way Tank bottom detection OFF0D61Parameter must be configured in this way First echo factor unchanged, but if previously smaller than 30, than: 0D530D51→ Note 3FEF threshold 00D52→ Note 3FEF at near distance 30 dB 0D53→ Note 3FEF distance near 500 mm 0D54→ Note 3FEF distance far 3000 mm0D55Parameter must be configured in this way Max. filling speed 0 mm/s (factory setting)0D15Parameter must be configured in this way Max. drain speed 0 mm/s (factory setting)0D16Parameter must be configured in this wayOtherDetection window OFF0A7Parameter must be configured in this way Hysterese width 0 mm (factory setting)0D14Parameter must be configured in this way Communication address 0060Parameter must be configured in this way Current output mode "Standard" if previously "Fixed current" 063Parameter must be configured in this way SimulationSim. / OFF065Parameter must be configured in this wayLockingThe device must be locked once the Micropilot M has been calibrated as per the Operating Instructions.Type of locking Code/action Position/VU331 displayHardware (recommended) 3 keys together "lock"Locally via VU331 display (keys O and S and F)↓Software (mandatory)WHG (german)018UnlockingThe device is unlocked by firstly removing the hardware lock by locally pressing all the three keys together viathe VU331 LCD display and then by setting the "Overfill protection" parameter (Position 018) to "Standard" ifnecessary.Type of unlocking Code/action Position/VU331 displayHardware (if locked) 3 keys together "unlock"Locally via VU331 display (keys O and S and F)↓Software Standard018Maintenance Please refer to the relevant Operating Instructions (→ä7, "Supplementary device documentation") forinstructions on maintenance and recalibration.Alternative monitoring measures must be taken to ensure process safety during configuration, proof-testing andmaintenance work on the device.Proof-testProof-test Check the operativeness and safety of safety functions at appropriate intervals!The operator must determine the time intervals.You can refer to the diagram "Proof-test interval" →ä9, →ä10, for this purpose.Proof-testing of the device can be performed as follows:–Approaching the level (→ test sequence A).–Removing the device and measuring a medium with comparable properties (→ test sequence B).You must also check that all cover seals and cable entries are sealing correctly.Process for proof-testing Test sequence APreparation1.Connect suitable measuring device (recommended accuracy better ±0.1 mA) to the current output.2.Determine the safety setting (level limit monitoring).Procedure for level limit monitoring1.Approach the level directly below (MAX monitoring) or directly above (MIN monitoring) the level limitto be monitored.2.Read the output current, record it and assess for accuracy.3.Approach the level directly above (MAX monitoring) or directly below (MIN monitoring) the level limitto be monitored.4.Read the output current, record it and assess for accuracy.5.The test is deemed successful if the current in step 2 does not result in activation of the safety functionbut the current in step 4 does.!Note!The proof-test is deemed to have failed if the expected current value deviates for a specific level by >±10%.For troubleshooting, → Operating Instructions (→ä7, "Supplementary device documentation"), Section 9.98% of dangerous, undetected failures are detected using this test.Test sequence BPreparation1.Prepare the test tank with the medium (dielectric constant comparable to that of the medium to bemeasured).For installation instructions, → Operating Instructions (→ä7, "Supplementary devicedocumentation"), Section 3.2.Remove the device and mount it in the test tank.3.Perform interference echo mapping if the shape and size of the test tank is different.4.Connect suitable measuring device (recommended accuracy better than ±0.1 mA) to the current output.5.Determine the safety setting (level limit monitoring).Procedure for level limit monitoring→ Test sequence A!Note!The proof-test is deemed to have failed if the expected current value deviates for a specific level by > ±10%.For troubleshooting, → Operating Instructions (→ä7, "Supplementary device documentation"), Section 9.98% of dangerous, undetected failures are detected using this test."Caution!If an interference echo mapping was performed in the test tank, a valid interference echo mapping must beperformed after the device is mounted in the original tank.!Note!If one of the test criteria from the test sequences described above is not fulfilled, the device may no longer beused as part of a safety instrumented system.The purpose of proof-testing is to detect random device failures. The impact of systematic faults on the safetyfunction is not covered by this test and must be assessed separately.Systematic faults can be caused, for example, by process material properties, operating conditions, build-up orcorrosion.RepairsRepairs Repairs on the devices must always be carried out by Endress+Hauser.Safety functions cannot be guaranteed if repairs are carried out by anybody else.Exception:The following components can be replaced by the customer if the person responsible for doing so has beentrained beforehand by Endress+Hauser:–Sensor–HF module–Electronic insert–Terminal moduleThe replaced components must be sent to Endress+Hauser for the purpose of fault analysis.Once the components have been replaced, a proof-test must be carried out as per test sequence A (→ä15)or test sequence B (→ä15).In the event of failure of a SIL-labeled Endress+Hauser device, which has been operated in a protectionfunction, the "Declaration of Contamination and Cleaning" with the corresponding note "Used as SIL device inprotection system" must be enclosed when the defective device is returned.Please refer to the Section "Return" in the Operating Instructions (→ä7, "Supplementary devicedocumentation").AppendixCommissioning or proof test ArrayprotocolExida Management SummaryEndress+Hauser2122Endress+HauserEndress+Hauser23Instruments InternationalEndress+HauserInstruments International AGKaegenstrasse 24153 ReinachSwitzerlandTel.+41 61 715 81 00Fax+41 61 715 25 00***************.comSD00327F/00/EN/13.1071125885FM+SGML 6.071125885。

邦纳传感器-操作说明

邦纳传感器-操作说明

一、传感器适用范围iVu系列图像传感器用于监视标签、零件和包裹的大小、方向、定位、外形、位置等。

这个传感器集成了一个彩色的触摸屏,可用于图像装入、设置和简单的配置组态且不需连接电脑。

一些实例应用:•日期/签码检测•标签检测•零件蚀点检测•零件方向检测•零件外形检测•工件上的钻孔检测•印制工件检测•包装正确性检测(如:检测包装单在箱体的内部或上面;测试小瓶瓶盖良好)•泡罩包装检测•区域传感器适合检测固定的工件。

二、简单描述:提供此向导的目的是为快速掌握iVu系列传感器的必要信息。

它提供了此传感器的总揽,而且以图解的方式说明了如何设定传感器来检测标签、工件、包装等。

三、邦纳传感器报价税后是:14200RMB四、使用步骤1、退出演示模式(只第一次使用时进行此操作)第一次给iVu 系列传感器上电,它会进入演示模式。

演示模式以保存的图像和检测参数来示范如何配置传感器,而不需要考虑聚焦、光源或是触发。

在这种模式下,你可以学到如何对这三种传感器形式进行调整,观察到调整对整个图像的影响。

要退出演示模式,可以通过主菜单-系统-传感器类型,然后选择退出演示模式。

当退出演示模式后,传感器重启进入正常操作模式。

注意:你可以随时通过“主菜单-系统-传感器类型-选择进入演示模式”的方式回到演示模式。

当退出演示模式时,需要重启传感器实现图形模式匹配设置,通过以下步骤更改传感器类型: 1)在屏幕的左下角,点击此图标, 显示如下主菜单2)在主菜单中点击图标,显示如下系统菜单3)点击传感器型号,在监视器上选择工具,再点击”Apply应用”图标4)点击主屏幕左上角的图标,就是可以回到主屏幕(如果没有演示模式就不用进行上述操作了)2、选择外部触发(外部触发是运行,内部触发是调试)1)默认状态的触发方式是内部触发,可以更改到外部触发(主菜单图标>图像图标>触发>外部2)外部触发进行的设置(主菜单图标>系统设置图标>开关量I/O>输入极性>选择高电平到低电平>返回>输入上拉>选择使能>返回>输出1和2都选错误)演示图如下:3、获得图像1)通过调整安装角度来获得被检测物清晰对比分明的图像,通过附带的安装支架很容易的在线调整传感器的安装位置,使被检测物的图像全部显示在屏幕上。

mavin传感器

mavin传感器

mavin传感器mavin称重传感器 139 **** ****(一)单点式称重传感器NA1称重传感器,用于计价秤,计数秤NA1-3kg NA1-6kg NA1-10kg NA1-20kg NA1-30kg NA1-35kg NA1-40kg NA1-45kg NA2称重传感器,用于计价秤,计数秤NA2-60kg NA2-100kg NA2-150kg NA2-200kg NA2-300kg NA2-350kg NA2-500kgNA3称重传感器,用于台秤NA3-50kg NA3-60kg NA3-100kg NA3-150kg NA3-200kg NA3-250kg NA3-300kgNA3-500kg NA3-600kg NA3-750kg NA3-800kg NA3-1000kg NA3-1500kg NA3-1tNA3-1.5tNA4~5称重传感器,用于台秤NA4-60kg NA4-100kg NA4-200kg NA4-250kg NA4-300kg NA4-500kg NA4-800kgNA5-60kg NA5-100kg NA5-200kg NA5-250kg NA5-300kg NA5-500kg NA5-800kgNA6称重传感器,用于计价秤,计数秤,天平秤NA6-0.3kg NA6-0.5kg NA6-0.6kg NA6-0.75kg NA6-1kg NA6-2kg NA6-3kg NA6-4kg NA6-5kg NA6-7kg NA6-10kgNA8称重传感器,用于计价秤,计数秤NA8-60kg NA8-100kg NA8-150kg NA8-200kg NA8-250kgNA10称重传感器,用于计价秤,计数秤,计重秤NA10-30kg NA10-35kg NA10-45kg NA10-50kg NA10-60kg NA10-80kg NA10-100kg NA10-120kgNA11称重传感器,用于台秤NA11-60kg NA11-100kg NA11-150kg NA11-200kg NA11-250kg NA11-300kgNA11-350kg NA11-500kg NA11-800kg NA11-1000kg NA11-1tNA12~13称重传感器,用于计价秤,计数秤,天平秤NA12-0.3kg NA12-0.5kg NA12-0.6kg NA12-0.75kg NA12-1kg NA12-2kg NA13-0.3kg NA13-0.6kgmavin称重传感器NA14称重传感器NA17称重传感器NA17-60kgNA19称重传感器,用于工业称重系统NA19-150kg NA19-250kg NA19-500kgNA20称重传感器,用于台秤,料斗秤NA20-5kg NA20-10kg NA20-20kg NA20-50kg NA20-100kg NA20-200kg NA20-500kg NA21称重传感器,用于台秤NA21-500kg NA21-1000kg NA21-1200kg NA21-1500kg NA21-0.5t NA21-1tNA21-1.2t NA21-1.5tNA22~23称重传感器,用于计价秤,计数秤NA22-6kg NA22-10kg NA22-15kg NA22-20kg NA22-30kg NA22-35kg NA22-40kgNA33-6kg NA33-10kg NA33-15kg NA33-20kg NA33-30kg NA33-35kg NA33-40kgNA24称重传感器,用于电子秤,台秤NA24-60kg NA24-100kg NA24-150kg NA24-200kg NA24-250kg NA24-300kgNA24-350kg NA24-500kgNA25称重传感器,用于电子秤,台秤NA25-60kg NA25-100kg NA25-150kg NA25-200kg NA25-250kg NA25-300kgNA25-350kg NA25-500kgNA26称重传感器,用于口袋秤,邮包秤NA26-5kg NA26-10kg NA26-15kg NA26-20kg NA26-25kg NA26-30kgNA27称重传感器,用于厨房秤,手提秤NA27-0.5kg NA27-1kg NA27-2kg NA27-3kg NA27-5kg NA27-6kg20.NA31称重传感器,用于天平秤,珠宝秤NA31-0.02kg NA31-0.05kg NA31-20g NA31-50gmavin称重传感器NA32`~33称重传感器,用于计价秤,邮包秤NA32-3kg NA32-6kg NA32-15kg NA32-20kg NA32-30kg NA32-40kg NA32-60kgNA32-80kg NA32-150kgNA33-3kg NA33-6kg NA33-15kg NA33-20kg NA33-30kg NA33-40kg NA33-60kgNA33-80kg NA33-150kgNA34称重传感器,用于口袋秤NA34-0.3kg NA34-0.6kg NA34-1kgNA34-300g NA34-600g NA34-1000gNA36称重传感器,用于口袋秤NA36-0.5kg NA36-1kg NA36-500g NA36-1000gNA37称重传感器NA39称重传感器NA45称重传感器NA45-20kgNA51称重传感器,用于计价秤,计数秤,计重秤NA51-30kg NA51-35kgNA73称重传感器,用于口袋秤,珠宝秤NA73-0.1kg NA73-0.15kg NA73-0.2kgNA73-100g NA73-150g NA73-200gNA115~117称重传感器,用于台秤,灌装秤NA115-50kg NA115-100kg NA115-150kg NA115-200kgNA116-250kg NA116-500kg NA117-750kg NA117-1000kg NA117-2000kg NA116-0.5t NA117-0.75t NA117-1t NA117-2tNA125称重传感器NA125-2kgNA128称重传感器,用于计价秤,计数秤,计重秤,台秤NA128-5kg NA128-15kg NA128-20kg NA128-30kg NA128-40kg NA128-50kgNA128-75kg NA128-100kg NA128-200kgNA148称重传感器,用于桌秤NA148-5kg NA148-10kg NA148-15kg NA148-20kg NA148-25kg NA148-30kgNA148-35kg NA148-40kgNA151称重传感器,用于机改电NA151-10kg NA151-20kg NA151-40kg NA151-60kg NA151-150kgNA164称重传感器,用于台秤NA164-500kg NA164-750kg NA164-800kgNA165称重传感器,用于计价秤,计数秤NA165-3kg NA165-5kg NA165-6kg NA165-10kg NA165-15kg NA165-20kg NA165-30kg NA165-35kg NA165-40kgNA187称重传感器,用于计价秤,计数以上内容技术参数以《OIML60号国际建议》最新具体变化可查看《JJG669—12 台湾mavin上海季冉实业传感器部门检定规程》。

高精度称重变送器4-20mA和0-10V输出

高精度称重变送器4-20mA和0-10V输出

称重变送器也叫做重量变送器,是一种将物理量变换成电信号,将毫伏信号输出的传感器经隔离放大转换成标准直流信号的变送器。

通常采用SMT工艺,针对工业过程的电阻应变式信号传感器而设计制造,适用于于不同规格称重传感器。

A/D转换器,具有输入信号范围宽,分辨率高,零点和满载温漂小的特点。

模块采用螺丝固定安装方式可方便的嵌入控制柜。

该模块通信协议采用Modbus通信协议,可方便的连接各种PLC称重控制系统,组态软件,DCS,以及电脑集中监控系统。

称重变送器广泛应用于各类称重信号变送,输出4-20mA,0-10V,0-5V,RS232,RS485,modbus通讯。

JNS996数字式称重放大器,具有精度高,抗干扰性能好,解决了大量程称重传感器难标定,标定不准确的问题。

工作电源:◆DC24V (电源范围:18-36V),功率约8W ,文章较长,点击阅读全文,后面有惊喜。

额定输出:0~5v、0~10v、0~±5v、0~±10v、0~20mA 0~10mA、4~20mA安装方式:◆35mm导轨安装(防护等级:IP40)标定方法:◆砝码标定(通过按键输入重量值标定零点和量程)◆数字标定(无需砝码,直接输入称重传感器的参数进行标定)称重处理:◆AD采样方法:Delta-Sigma方法◆AD采样速率:100次/秒◆内部分辨率:1/260000◆显示分辨率:1/50000◆精度:0.005& F.S称重接口: ◆输入灵敏度:≥0.25uV/d◆输入信号范围:-30.5mV~+30.5mV◆零点信号范围:-30.5mV~+30.5mV◆传感器激励电压:10V◆传感器驱动能力:4只350Ω的传感器开关量接口:◆输入接口2个:置零、去皮、毛重/净重、打印等选其一◆输出接口2个:可设置两个高低位开关量输出信号输出:◆模拟量输出:4-20mA,0-10V,0-5V 任选其一◆数字量输出:RS232,RS485 (通讯协议:MODBUS RTU)其它参数:◆使用环境温度:-20℃~45℃◆相对湿度:10&~90& 无冷凝◆显示:6位高亮度红色数码管◆指示灯:6个◆按键数量:6个◆重量:0.4kg数据恢复:◆客户设置好参数后,将参数保存,以后万一将参数调乱,可以通过数据恢复功能,直接恢复。

蜂蜜伟尔重型压力传感器说明书

蜂蜜伟尔重型压力传感器说明书

19C500G719C100A719C015A7/sensing 1 Heavy Duty products. Built for the toughest applications. Honeywell Sensing and Control (S&C) offers decades of experience in the heavy duty pressure products industry. That’s why, industry-wide, our heavy duty pressure sensors and transducers are known for enhanced quality, reliability, and service – which adds up to outstanding value for your applications.Heavy Duty Pressure Sensors are small, allowing them to be used on their own in tight packages or as the building block for a complete transducer. The 13 mm Series and the 19 mm Series were developed for potential use in pressure applications that involve measurement of hostile media in harsh environmentsFEATURESHEAVY DUTY PRESSURE SENSORS13 mm Series.Features: Rugged, isolated stainless steel package • Accommodates media that will not adversely affect 316L stainless steel • Based on reliable semiconductortechnology • Calibrated and temperature compensated • Voltage or current supply options • Absolute and sealed gagepressures • For potential applications from 500 psi to 5,000 psiBenefits: Used in high pressure potential applications involving measurement of hostile media in harsh environments.Piezoresistive semiconductor sensor chip in oil-isolated housing with or without an integral ceramic for temperaturecompensation and calibration is designed to provide reliable, stable, and accurate performance. Weld-ring collar and special back support ring for enhanced cycle life capability as well as further package integration in OEM applications. Potential applications include industrial andHeavy DutyPressure Sensors/Transducers Line Guidecontinued on page 4hydraulic controls, tank pressure, pressure transmitters, and process control systems.19 mm Series.Features: Rugged, isolated stainless steelpackage • Accommodates media that will not adversely affect 316L stainless steel • Small size • Based on reliablesemiconductor technology • Absolute and gage pressures • Vacuum compatible, isolated sensors • Calibrated andtemperature compensated (some listings) • For potential applications up to 500 psi Benefits: Variety of pressure connections allow use in wide range of OEMequipment. Uncompensated version for use in potential applications using specialized circuit designs. Rugged for use in potential applications where corrosive liquids or gases are monitored and may also be exposed to a vacuum such as industrial controls, process control systems, industrial automation and flow control, and pressure calibrators.HEAVY DUTY PRESSURE TRANSDUCERSPX2 Series.Features: Designed for configurability • Cost-effective • Application expertise • Global support • Industry-leading Total Error Band (TEB) • Durable • Designed to Six Sigma standards • Energy efficient • Broad compensated temperature range • Good EMC protectionBenefits: Numerous standard or custom connectors, ports, pressure types and ranges, and output options allow configuration to meet specific application needs, quick availability of product samples, and reduce design and implementation costs of the end product. Honeywell’s knowledgeable application engineers are available to answer specific design questions during the development, launch, and production of the customers’ product. Honeywell’s global presence offers immediate product and application support throughout thecompatible with 316 stainless steel, a type of steel thatincreases corrosion resistance, improves resistance to pitting from chloride ion solutions, and provides increased strength at high temperatures.Heavy Duty Pressure Transducers are complete amplified and compensated pressure measurement solutions. With a choice of ports, connectors, outputs and pressure ranges, the PX2 Series, MLH Series and SPT Series transducers can be configured to meet the needs of the application. They are engineered to be resistant to a wide variety of media for use inmost harsh environments.2 /sensingWhen reliability is demanded, Honeywell delivers.Heavy Duty Pressure Sensors and Transducers are found in applications where they cannot be easily replaced — where supreme durability is a top priority. That’s why you’ll find Honeywell S&C heavy duty pressure products performing expertly in many potential applications, such as compressors and hydraulic controls, and in industries as diverse as aerospace, medical, transportation, agriculture, refrigeration, and industrial. Our full line of products deliver enhanced performance and reliability, plus: absolute, gage and sealed-gage measurement; a wide array of pressure ranges, port styles, termination types, and outputs; package types from miniature surface mount sensors to high-end stainless steel isolated (for stringent process control); pressure ranges from 3 psi to 8,000 psi; and corrosion resistance.Heavy Duty Pressure Sensors/Transducers Line Guide/sensing 3Sensing and Control Honeywell1985 Douglas Drive North Golden Valley, MN 55422 USA+1-815-235-6847/sensing 008154-7-EN IL50 GLOJuly 2012Copyright © 2012 Honeywell International Inc. All rights reserved.development cycle. Industry-leading Total Error Band of ±2% over a compensated temperature range of -40 °C to 125 °C [-40 °F to 257 °F] provides excellent interchangeability due to minimal part-to-part variation in accuracy, eliminates individual transducer testing and calibration, and supports system accuracy and warranty requirements. Compatible with a wide variety of harsh media (brake fluid, refrigerants, engine oil, tap water, hydraulic fluids, and compressed air), wide operating temperature range, up to IP69K sealing, and CE compliance allow for use in tough environments. Designed to Six Sigma standards, providingthe highest level of product quality, performance, and consistency. Broad compensated temperature range allows the same transducer to be designed into a broad set of applications. Good EMC protection means that the transducerwill not be damaged by environmental electromagnetic interference. Potential applications include industrial HVAC/R and air compressors; general systemand factory automation pump, valve and fluid pressure; and transportation (heavy equipment and alternative fuel vehicles) system, pneumatics, light hydraulics, brake and engine oil pressure.MLH Series.Features: All-metal wetted parts • No internal elastomeric seals • Stableand creep free • Input reverse voltage protection • Less than 2 ms response time • Easy customization • Rated IP65 or better • Exceeds CE heavy industrial EMC for use in areas of high RFI/EMI• Amplified and temperature compensated • Wide choice of connections and terminations • Calibration for special pressure ranges Benefits: Combines ASIC technologywith media isolated, metal diaphragm.All-metal wetted parts for use in a varietyof potential fluid applications. Amplifiedoutputs often eliminate cost of externalamplifiers. Wide selection of industry-standard connectors and processports for enhanced reliability and userflexibility. Potential applications includecompressors, refrigeration and HVAC/R,general industrial and hydraulics, multipletransportation applications includingbraking and alternate fuels, medical.SPT Series.Features: Based on reliablesemiconductor technology • Rugged,316L stainless steel wetted parts• Calibrated and temperaturecompensated • Absolute, gage, sealedgage, and vacuum gage pressures• For use in potential medical applicationswhere compatibility is a problem.Benefits: Variety of pressureconnections allows use in wide rangeof OEM equipment. For use in potentialapplications where corrosive liquids andgases are monitored such as industrialautomation and flow control, pressureinstrumentation, hydraulic systems, andprocess control.Warranty. Honeywell warrants goods ofits manufacture as being free of defectivematerials and faulty workmanship.Honeywell’s standard product warrantyapplies unless agreed to otherwise byHoneywell in writing; please refer to yourorder acknowledgement or consult yourlocal sales office for specific warrantydetails. If warranted goods are returned toHoneywell during the period of coverage,Honeywell will repair or replace, at itsoption, without charge those items it findsdefective. The foregoing is buyer’s soleremedy and is in lieu of all warranties,expressed or implied, including thoseof merchantability and fitness for aparticular purpose. In no event shallHoneywell be liable for consequential,special, or indirect damages.While we provide application assistancepersonally, through our literature andthe Honeywell web site, it is up to thecustomer to determine the suitability of theproduct in the application.Specifications may change without notice.The information we supply is believed tobe accurate and reliable as of this printing.However, we assume no responsibility forits use.For more information about Sensing andControl products, visit www.honeywell.com/sensing or call +1-815-235-6847*************************************4 /sensing19C500G719C100A719C015A7。

台湾mavin称重传感器

台湾mavin称重传感器

台湾mavin称重传感器台湾mavin称重传感器(一)单点式称重传感器NA1称重传感器,用于计价秤,计数秤NA1-3kg NA1-6kg NA1-10kg NA1-20kg NA1-30kg NA1-35kg NA1-40kg NA1-45kg NA2称重传感器,用于计价秤,计数秤NA2-60kg NA2-100kg NA2-150kg NA2-200kg NA2-300kg NA2-350kg NA2-500kgNA3称重传感器,用于台秤NA3-50kg NA3-60kg NA3-100kg NA3-150kg NA3-200kg NA3-250kg NA3-300kgNA3-500kg NA3-600kg NA3-750kg NA3-800kg NA3-1000kg NA3-1500kg NA3-1tNA3-1.5tNA4~5称重传感器,用于台秤NA4-60kg NA4-100kg NA4-200kg NA4-250kg NA4-300kg NA4-500kg NA4-800kgNA5-60kg NA5-100kg NA5-200kg NA5-250kg NA5-300kg NA5-500kg NA5-800kgNA6称重传感器,用于计价秤,计数秤,天平秤NA6-0.3kg NA6-0.5kg NA6-0.6kg NA6-0.75kg NA6-1kg NA6-2kg NA6-3kg NA6-4kg NA6-5kg NA6-7kg NA6-10kgNA8称重传感器,用于计价秤,计数秤NA8-60kg NA8-100kg NA8-150kg NA8-200kg NA8-250kgNA10称重传感器,用于计价秤,计数秤,计重秤NA10-30kg NA10-35kg NA10-45kg NA10-50kg NA10-60kg NA10-80kg NA10-100kg NA10-120kgNA11称重传感器,用于台秤NA11-60kg NA11-100kg NA11-150kg NA11-200kg NA11-250kg NA11-300kgNA11-350kg NA11-500kg NA11-800kg NA11-1000kg NA11-1tNA12~13称重传感器,用于计价秤,计数秤,天平秤NA12-0.3kg NA12-0.5kg NA12-0.6kg NA12-0.75kg NA12-1kg NA12-2kg NA13-0.3kg NA13-0.6kg台湾mavin称重传感器NA14称重传感器NA17称重传感器NA17-60kgNA19称重传感器,用于工业称重系统NA19-150kg NA19-250kg NA19-500kgNA20称重传感器,用于台秤,料斗秤NA20-5kg NA20-10kg NA20-20kg NA20-50kg NA20-100kg NA20-200kg NA20-500kg NA21称重传感器,用于台秤NA21-500kg NA21-1000kg NA21-1200kg NA21-1500kg NA21-0.5t NA21-1tNA21-1.2t NA21-1.5tNA22~23称重传感器,用于计价秤,计数秤NA22-6kg NA22-10kg NA22-15kg NA22-20kg NA22-30kg NA22-35kg NA22-40kgNA33-6kg NA33-10kg NA33-15kg NA33-20kg NA33-30kg NA33-35kg NA33-40kg NA24称重传感器,用于电子秤,台秤NA24-60kg NA24-100kg NA24-150kg NA24-200kg NA24-250kg NA24-300kgNA24-350kg NA24-500kgNA25称重传感器,用于电子秤,台秤NA25-60kg NA25-100kg NA25-150kg NA25-200kg NA25-250kg NA25-300kgNA25-350kg NA25-500kgNA26称重传感器,用于口袋秤,邮包秤NA26-5kg NA26-10kg NA26-15kg NA26-20kg NA26-25kg NA26-30kgNA27称重传感器,用于厨房秤,手提秤NA27-0.5kg NA27-1kg NA27-2kg NA27-3kg NA27-5kg NA27-6kg20.NA31称重传感器,用于天平秤,珠宝秤NA31-0.02kg NA31-0.05kg NA31-20g NA31-50g台湾mavin称重传感器NA32`~33称重传感器,用于计价秤,邮包秤NA32-3kg NA32-6kg NA32-15kg NA32-20kg NA32-30kg NA32-40kg NA32-60kgNA32-80kg NA32-150kgNA33-3kg NA33-6kg NA33-15kg NA33-20kg NA33-30kg NA33-40kg NA33-60kgNA33-80kg NA33-150kgNA34称重传感器,用于口袋秤NA34-0.3kg NA34-0.6kg NA34-1kgNA34-300g NA34-600g NA34-1000gNA36称重传感器,用于口袋秤NA36-0.5kg NA36-1kg NA36-500g NA36-1000gNA37称重传感器NA39称重传感器NA45称重传感器NA45-20kgNA51称重传感器,用于计价秤,计数秤,计重秤NA51-30kg NA51-35kgNA73称重传感器,用于口袋秤,珠宝秤NA73-0.1kg NA73-0.15kg NA73-0.2kgNA73-100g NA73-150g NA73-200gNA115~117称重传感器,用于台秤,灌装秤NA115-50kg NA115-100kg NA115-150kg NA115-200kgNA116-250kg NA116-500kg NA117-750kg NA117-1000kg NA117-2000kg NA116-0.5t NA117-0.75t NA117-1t NA117-2tNA125称重传感器NA125-2kgNA128称重传感器,用于计价秤,计数秤,计重秤,台秤NA128-5kg NA128-15kg NA128-20kg NA128-30kg NA128-40kg NA128-50kgNA128-75kg NA128-100kg NA128-200kgNA148称重传感器,用于桌秤NA148-5kg NA148-10kg NA148-15kg NA148-20kg NA148-25kg NA148-30kgNA148-35kg NA148-40kgNA151称重传感器,用于机改电NA151-10kg NA151-20kg NA151-40kg NA151-60kg NA151-150kgNA164称重传感器,用于台秤NA164-500kg NA164-750kg NA164-800kgNA165称重传感器,用于计价秤,计数秤NA165-3kg NA165-5kg NA165-6kg NA165-10kg NA165-15kg NA165-20kg NA165-30kg NA165-35kg NA165-40kgNA187称重传感器,用于计价秤,计数秤,台秤NA187-50kg NA187-75kg NA187-100kg NA187-150kg NA187-200kg台湾mavin称重传感器台湾mavin称重传感器额定负荷60,100,150,200,250,300,350,500(kg)额定输出2.0 mV/V±5%非线性0.02 %F.S滞后0.02 %F.S重复性0.02 %F.S蠕变(20分钟) 0.02 %F.S输出温度影响0.002 %F.S/℃零点温度影响0.003 %F.S/℃零点平衡±0.0200 mV/V输入阻抗390±15 Ω;410±15 Ω输出阻抗350±5 Ω绝缘阻抗≥5000 MΩ安全过载率150 %F.S极限过载率200 %F.S工作温度范围-20~60 ℃推荐工作电压5~12 VDC最大工作电压15 VDC材质铝合金;钢合金防护等级IP66 / IP67电缆φ5×1.5 m台面尺寸350×450 mm接线方式红:电源+,黑:电源-,绿:信号+,白:信号以上内容技术参数以《OIML60号国际建议》92年版为基础,最新具体变化可查看《JJG669—12 台湾mavin广州南创传感器事业部检定规程》。

西安海天电子科技有限公司 D2002E 型电子称重仪表 调试说明书

西安海天电子科技有限公司 D2002E 型电子称重仪表 调试说明书

D2002E型电子称重仪表调试说明书2012年4月版▢!安全需知1、非专业人事,请勿拆卸称重显示器。

2、传感器与称重显示器的连接必须可靠,传感器的屏蔽线必须可靠接地,连接线不允许在称重显示器通电的状态下进行插拔,防止静电损坏称重显示器或传感器。

3、传感器和称重显示器都是静电敏感设备,在使用中,必须切实采取防静电措施,严禁在秤台上进行电焊操作或其他强电操作,在雷雨季节,必须落实可靠的避雷措施,防止因雷击造成传感器和称重显示器的损坏,确保操作人员的安全和称重设备及相关设备的安全运行。

4、请确保仪器可靠接地(接地阻抗<0.1Ω)。

勿与其它大功率负载共同接地。

目录第一章概述....................................................... (1)第二章技术参数..................................................................... (1)第三章安装连接 (2)第四章查看传感器内码 (9)第五章角差调整 (10)第六章标定 (11)第七章修改传感器的地址 (16)第八章线性校正功能设置 (17)第九章安装调试 (18)第十章操作方法 (20)第十一章定时关机功能................................................................... ............ (23)第十二章常见故障与解决方法 (24)第十三章维护保养及注意事项 (27)附录一:出厂默认参数 (28)附单 (29)第一章概述1.具有高精度、高可靠性。

2.一致性、互换性好。

3.信号抗干扰能力强:4.具有自我识别功能,便于故障诊断:5.具有较高的组秤灵活性。

6.最多可外接12只数字式称重传感器。

7.保密性好,增强防作弊功能。

第二章技术参数1、性能指标置零范围开机:±4% ±10% ±20% ±40% ±100%F.S 可选置零键:±1% ±2% ±4% ±10% ±20%F.S 可选2、显示 6位VFD显示,6个状态指示符。

Mettler-Toledo ACT350精密称重传感器快速指南说明书

Mettler-Toledo ACT350精密称重传感器快速指南说明书

Q u i c k G u i d e30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide2ACT350 Precision Quick GuideIntended UseYour weighing transmitter is used for weighing. Use the scale exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo, LLC will invalidate its warranty.It is essential for the buyer to closely observe the installation information, product and system manuals, operating instruc-tions and other documentation and specifications. MT’s warranty and any liability are expressly excluded for damages caused by non-compliance with the applicable manuals.DocumentationFor further details on system configuration and operation, refer to the documents provided on /ind-act350-downloadsSafety WarningsRead the Installation section on ACT350 Precision User Guide before operating or servicing this equipment, follow allinstructions carefully, and save all documentation for future reference.WARNINGSFOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG.WHEN THIS EQUIPMENT IS INCLUDED AS A COMPONENT PART OF A SYSTEM, THE RESULTING DESIGN MUST BE REVIEWED BY QUALIFIED PER-SONNEL WHO ARE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF ALL COMPONENTS IN THE SYSTEM AND THE POTENTIAL HAZARDS INVOLVED. FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS DETAILED IN THE USER MANUAL. INCORRECT OR SUBSTITUTE COMPONENTS AND/OR DEVIATION FROM THESE INSTRUCTIONS CAN IMPAIR THE SAFETY OF THE TRANSMITTER AND COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.BEFORE CONNECTING/DISCONNECTING ANY INTERNAL OR EXTERNAL ELECTRONIC COMPONENTS, LOAD CELLS, HARNESSES OR INTERCONNECT-ING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.DO NOT INSTALL, DISCONNECT OR PERFORM ANY SERVICE ON THIS EQUIPMENT BEFORE POWER HAS BEEN SWITCHED OFF AND THE AREA HAS BEEN SECURED AS NON-HAZARDOUS BY PERSONNEL AUTHORIZED TO DO SO BY THE RESPONSIBLE PERSON ON-SITE.THE ACT350 Precision IS NOT INTRINSICALLY SAFE! DO NOT USE IN HAZARDOUS AREAS CLASSIFIED AS DIVSION 1 AND DIVISION 2, ZONE 0, ZONE 20, ZONE 1, ZONE 2 OR ZONE 21 BECAUSE OF COMBUSTIBLE OR EXPLOSIVE ATMOSPHERES.ONLY 24VDC POWER SUPPLY IS AVAILABE TO CONNECT WEIGHT MODULES / SCALES TO ACT350 Precision. ALL OTHER WEIGHT MODULES REQUIRE AN EXTERNAL POWER SOURCE. CONFIRM VOLTAGE BEFORE USE!30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide 3Weight Display000000Displays weight information~Motion, weight is currently changing B/G Gross Mode KG/G/LBWeight Display UnitSCL Scales status: On okay, flashing indicates scale error PWR Power status: On okay, Off errorNW Automation Network status: On okay, flashing indicated network error DEV Device status: On okay, flashing contact service NW1Green: Link , Yellow: Active NW2Green: Link , Yellow: ActivePhysical DimensionsFront Panel and Display FeaturesUp/Down ArrowKeysUsed for data entryEnterEnter key /Zero scale/Enter Operator menuLeft Arrow Key Switch position/Return30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide4Bottom DIP SwitchSwitch 1Switch 2DescriptionOFFOFF Normal stateOn or OFFONMaster Reset of all data during transmitter power-up ON OFFNo functionACT350 Precision and Weigh Module/Scales Wire ConnectionCheck the Weigh Module or Scale manual to confirm the power supply voltage.It is recommended to connect ACT350 Precision with Weigh Module or Scale via RS232 or RS422 interface.In the case of using RS485 interface of Weigh Module, it connects RS485- to RX-/TX-, RS485+ to RX+/TX+ on the ACT350 Precision side.NOTICEThe TX and RX cross wiring between Weigh Module or Scale and ACT350 Precision should be done for correct connection. See below in the Table 1; Table 2.24VDC Power Source Weigh ModuleWhen the Weigh Module or Scale is powered by ACT350 Precision with 24VDCThe Weigh Modules such as WKC (24VDC), PBK-9_APW / PFK-9_APW and SLF6 can be powered by ACT350 Precision directly.ACT350 Precision Pin Assignment Weigh Module SignalAPW products examplesPin No.Signal RS232RS422RS485*PBK-9; PFK-9; SLF-6; WKC Cable colors** 1+24V VDC VDC VDC White2GND GND GND GNDBrown3RX-TX-RS485-Purple4RX+TX+RS485+Orange5TX-RX-RS485-Violet6TX+RX+RS485+Black7RxD TxDYellow8TxD RxDPink9GND GND +ShieldShield ShieldRed (RS232)Green (RS422)Table 1: Pin Assignment and signals connection wiring scheme with 24VDC Power Supply.When the Weigh Module or Scale is powered externally with 12VDC.* Some manuals also use A-(or D-) and B+(or D+) to refer to RS485- and RS485+ respectively.** Cable color of the METTLER TOLEDO standard cables.ATTENTIONThe Weigh Modules or Scales powered by 12VDC should be supplied using external power source.30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide530499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide6Wiring connection examples for APW productsAPW Weigh ModuleType Cable type / Power SupplyACT350 PrecisionWXSCable No: 11141979 only RS232Power Supply: powered externallyWMCWMSCable No: according to data sheet RS232/RS422Power Supply: 24 VDC powered by ACT350 PrecisionPBK9/PFK9Cable No: according to data sheet RS232/RS422Power Supply: 24 VDC powered by ACT350 Precision SLF6WKCTable 3: APW products wiring connection examples.NOTICEPlease refer to the individual Weigh Module or Scale connection installation guide for correct wiring instruction.Order Item No:30476263 (PROFINET)30476264 (EtherNet/IP)Common Errors Shown on DisplayOvercapacityWeight overload. The weight display shows blank:Undercapacity Weight underload. The weight display shows blank: Array PLC ConnectivityAll actual Device Description Files (GSDML / AOP) and PLC Sample Code files are available to be downloaded at:/ind-act350-downloads30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide730499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide8Keypad Operator Menu StructureThe operator setup functionality via keypad is limited. Full configuration is possible via Webserver.Enter operator menu: Long Press ENTER . Use UP and DOWN keys to switch between menu icons. Use ENTER key to enter the next level menu and LEFT key to return to previous rmationModelACT350 Precision Transmitter SN ############S/W Version #.##.#####.##PLCFieldbus #.#.##.#Station Name IP Address###.###.###.###MAC Address##:##:##:##:##:##/ind-act350-downloadsSet Comparators Limit 1..5Input value with keypadTest & Adjustment Test Mode – External or Internal Weight – Input test weight value AdjustmentMode – External or Internal Step Control – On or OffWeight – Input calibration weight valueDisplay Error Messages List of latest error messagesLanguage SelectSelect language for HMI dis-playInput-English, Chinese30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide 9Setup Capacity & Incr.Input scale unit Input scales capacityInput Scale readabilityFilterCut-off Frequency – Input frequency Weighing mode Environment PLCProtocol - SAIFormat – 1 block format or 2 block format Byte order – Automatic, standard, Byte & Word Swap Ethernet/IP- MAC Address- Input DHCP - Disable, Enable - Input IP Address - Input Subnet Mask - Input Gate Way Profinet- Device Name - MAC Address - Input IP Address - Input Subnet Mask - Input Gate WayConnection TypeSerial: RS232, RS422, RS485- Input Baud rate: 150 … 115200- Input Bits: 8/None/1…- Handshake: None or XON/XOFF Webserver- Enable - Disable30499331 | 01 | 09/2019METTLER TOLEDO ACT350 Precision Quick Guide10Error Messages Shown on DisplayCleaning the TransmitterUse a soft, clean cloth and mild glass cleaner. Do not spray cleaner directly onto transmitter. Do not use industrial solvents such as ac-etone.Disposal of Transmitter / WEEE InformationIn conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment Array (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU,per their specific requirements.Please dispose of this product in accordance with local regulations at the collecting point specified for electri-cal and electronic equipment.If you have any questions, please contact the responsible authority or the distributor from which you purchasedthis device.Should this device be passed on to other parties (for private or professional use), the content of this regulationmust also be related.Thank you for your contribution to environmental protection.30499331 | 01 | 09/2019 METTLER TOLEDO ACT350 Precision Quick Guide11Mettler-ToledoIm Langacher 448606 GreifenseeSwitzerlandPhone +41449442011Mettler-Toledo, LLC 30499331 Rev. 01, 09/2019To protect your METTLER TOLEDO product’s future:Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to these instructions and regular calibration and maintenance by our factory-trained service team ensure dependable and accurate operation, protecting your investment. Contact us about a METTLER TOLEDO service agreement tailored to your needs and budget.We invite you to register your product at /productregistration so we can contact you about enhancements, updates and important notifications concerning your /ACT350-Precision For more information。

恩拉福伺服液位计安装及使用手册XTG_Rev1.4

恩拉福伺服液位计安装及使用手册XTG_Rev1.4

2.5.1.1. 外部保险丝 ....................................................................................................... 19
2.5.1.2. 电缆密封和穿线导管......................................................................................... 19
2.5.1.3. 接地.................................................................................................................. 20
2.5.1.4. 接线端子室 ....................................................................................................... 20
2.4.4. 螺栓.................................................................................................................. 16
2.4.5. 接地.................................................................................................................. 17
3.1.1.1. 液位测量 .......................................................................................................... 28

耐德精密称重器 BBA4x9 系列用户指南说明书

耐德精密称重器 BBA4x9 系列用户指南说明书

SpecificationsInterfacesThe instruments are fitted with one RS232 interface as standard. In addition, one of the following options is available:• Second RS232 interface • RS422/RS485 interface • Ethernet interface• Wireless LAN interface • USB (slave) interface• Digital I/O (with 4 inputs and 4 outputs)Further options• Internal storage battery (including AC charging adapter)• Version for external 12 to 24 VDC power supplyOptions that cannot be used in hazardous areas• External storage battery for model BBA4x9 (including AC charging adapter)OptionsModel BBA429 BBA439check BBA449check+ IND429 IND439check IND449check+Type of construction Compact balanceWeighing terminalBasic functions Zero setting • • • • • •Taring • • • • • •Change of unit • • • • • •Printing/data transfer • • • • • •MinWeigh • • • • • •Counting – – • – – •Info – – • – – •Identification (2 values) – – • – – •Date/time – – • – – •Tare definition – – • – – •Checkweighing Numeric display • • • • • •± application (check, check+) – • • – • •Bargraph ± display – • • – • •Colored ± display – • • – • •Input modes for target weights – 3 3 – 3 3Input modes for target quantities – – 2 – – 2Classify – – • – – •Standard tolerances – • • – • •«Take-away» mode – – • – – •Memory for ± data records – 99 99 – 99 99Memory for classification parameters – – 99 – – 99MiscellaneousBalance connections – – – 1 1 1Number of keys 6 10 25 6 10 25Battery operation (optional) • • • • • •IP69k protection • • • • • •Version with analog balance interface – – – • • •Version with IDNet balance interface – – – • • •Version for Zone 2/22 hazardous areas – ––•••(Category 3)AccessoriesGA46 thermal printer, stainless steel housing, RS232 interface, incl. 2.5 m cable 00505471 *1GA46 thermal printer, stainless steel housing, RS232 interface, incl. 0.4 m cable00507229 *1GA46 W thermal printer, stainless steel housing, RS232 interface, IP65, protective cover, take-up device, incl. 2.5 m cable00505799 *1GA46 W thermal printer, stainless steel housing, RS232 interface, IP65, protective cover, take-up device, incl. 0.4 m cable00507230 *1RS232 cable for PC (3 m, 8 pin <–> 9 pin Sub D socket) 00504376 *2RS232 male connector, 8 pin00503756 *2RS422/RS485 cable (3 m, 6 pin <–> open ends) 00204933 *2RS485 male connector, 6 pin00204866 *2Ethernet 10/100 Base T twisted pair cable (5 m –> 8 pin RJ45) 00205247 *2Ethernet 10/100 Base T twisted pair cable (20 m –> 8 pin RJ45) 00208152 *2USB adapter cable (0.2 m –> USB series A socket) 22006268 *2USB adapter cable (3 m –> USB series A socket) 22007713 *2Relay box for digital I/O option (same as for IND690) 22011967 *1Cable between digital I/O option (same as for IND690) 00504458 *2Digital I/O male connector, 19 pin00504461 *2Protective cover for BBA4x9 instruments (set of 3 covers) 22013992 *1Protective cover for IND4x9 terminals (set of 3 covers) 22013963 *1Stand, stainless steel, for IND4x9, height 330 mm 22013964 Stand, stainless steel, for IND4x9, height 660 mm22013965 Stand, stainless steel, for IND4x9 and KA-, KB-, MA-, MB- and DB- weighing platforms, height 330 mm 22014836 Bench support, stainless steel, for IND4x9, suitable for bench stand 00503632 and 00504854, height 500 mm22014835 Floor stand, stainless steel, for IND4x9, height 1000 mm22014834 ADI419 secondary display (IP69k, RS232, 3m cable incl., display without backlighting) 22013962 *1ADI419-B secondary display (IP69k, RS232, 3m cable incl., display with backlighting) 22014022 *1Stand base for floor stand22011982 Wall adapter, stainless steel, for IND4x9, tilting22013966 Wall bracket, stainless steel, for IND4x9, tilting and rotating22014833 GA46 mounting adapter, stainless steel, for bench and floor stand and wall bracket 22011985 *1External storage battery (additional storage battery for BBA4x9, excluding charger) 22013988 *1Charger for external and internal storage battery22014056 *1The following statements apply to installations in hazardous areas:*1 This instrument/accessory must not be used in hazardous areas!*2 This accessory is suitable for connecting a terminal in a hazardous area to an instrument in a non-hazardous area.Subject to technical changes © Mettler-Toledo AG MCG 05/08Printed in Germany 22 014 096 ADimensionsSales and service:For more informationService XXL• Integral service plan• Custom-designed service packets • Service contracts• On-site calibration certificates• Minimum weight determination with MinWeigh Quality certificate.Development, production and testing toISO9001. Environmental management system to ISO14001.«Conformité Européenne».This mark means you can rest assured that our products meet the requirements of thelatest EU guidelines.BBA4x9checkModel A B C D E F G H I A 300 235 102,5 216 240 175 380 432 228BB 400 335 104,5 216 300 235 450 432 230Colored tolerance control for unmistakable results!C h e c k w e i g h e r sThe optimal solution for manual checkweighing:4 Series with check application • Hygienic design • Colored backlighting • Fast and precise • Flexibly adjustableIP69k GMP EHEDG NSFThe perfect solutionfor convenient checkweighingIP protectionWith IP69k protection according to DIN 40050, the balances withstand even the harshest environments.The instruments are dustproof and also suitable for cleaning with high-pressure equipment.Good Manufacturing Practice“Very good for working to GMP!”. That’s how the IND4x9 terminals and BBA4x9 com-pact balances were rated by the Steinbeis Transfer Institute of Berlin University. The evaluation included cleanability, calibration, surfaces, and the qualifi-cation documentation.DisplayColor backlit 7-digit 7-segment LC dis-play. Brightness and colors individually adjustable.IND4x9 weighing technology The complete range of METTLERT OLEDO weighing platforms can be connected to the IND4x9 terminals. Terminal variants with analog and digital (IDNet) balance interfaces are optionally available. Most analog bal-ances from other manufacturers can also be used. You will find the metro-logical data in the operating instruc-tions or the data letter of the terminal.InterfacesA number of different interfaces are available for computer and printerc onnections (see options). The pro-tected interfaces are installed on the back of the instrument where they are easily accessible via IP69k protectedsockets.Wireless LANCommunication without cables! The IND4x9 terminals and BBA4x9 com-pact balances are optionally available with a WLAN interface according to IEEE 802.11b. The instruments can therefore be integrated into a WLAN network without problem. Data security is assured by WEP and WPA encryp-tion. The WLAN module is convenientlyconfigured with a WEB browser.GMPC h e c k w e i g h e rsIntrinsic safetyAll IND4x9 terminals are available in an intrinsically safe version for hazard-ous areas. As non-sparking equipment they fulfill the requirements of Category 3 and can therefore be used in Zones 2 (Gas) and 22 (Dust).A comprehensive range of weigh-ing platforms for hazardous areas isa vailable.Hygienic design, fast processing of measurement values,and the innovative color display set new standards in the industryModel BBA4x9MobilityAs an option, the instruments can also be supplied with a built-in storage bat-tery. A charge status indicator warns you in good time when the battery needs recharging. A single charge of the battery allows between 9 and 90 hours of network-independent opera-tion.9 h: continuous operation90 h: 10% operating time, power-offmode switched onFor the instruments of the BBA4x9 series a version with external storage battery is available. It is advisable to use a second storage battery. While the first battery is working, the othercan be recharged.Hygienic designwithout compromiseavailable:240x300 mm and 300x400 mm.For non-certifiable use, up to 30,000points can be displayed. For certifiableapplications, a resolution of up to 2 x3000e (multirange) is possible.CheckweighingThe optimal solution for manualcheckweighing is provided with the“check” and “check+” software mod-ules. Flexible setting possibilities in theSetup menu allow the instruments tobe adapted to different processes. Theintuitive operation reduces the trainingeffort and helps avoid incorrect inputs!HygieneThe IND4x9 weighing terminalsand BBA4x9 compact balances werespecially designed for use in hygieni-cally sensitive areas.The smooth surfaces and the materi-als used allow easy and thoroughcleaning. Even the back of the instru-ment has an impressively smooth,closed surface. The National SanitationFoundation (NSF) and European Hygi-enic Engineering and Design Group(EHEDG) have performed a positiveevaluation of the instruments. Cor-responding certificates and reports areavailable at .EHEDGprovides clarityColored display for unmistakable resultsThe colored backlighting of the LC display pro-vides easily readable unmistakable information as to whether or not the weight is within the tolerance limits! If you don't like our choice of colors, you can mix other colors in the Setup menu. The dis-play brightness is also adjustable. The bargraph provides additional information about the distance from the target weight.YellowWeight above the toleranceGreenWeight within the toleranceRedWeight below the toleranceDimmed grayCheckweighing not activated or net < = 0Flexible processes for convenient workingThe “check” and “check+” software modules are specially designed for manual checkweighing. The “check+” software module also allows manual checkweighing as well as classification into up to 5 classes. Numerous setting possibilities in the Setup menu make adaptation to individual requirements child’s play:• 3 different possibilities for inputting the target weight and tolerances Absolute: Definition of the lower and upper weight or quantity limits Relative: Definition of target weight or target quantity, + and – tolerances as weight values or quantitiesPercent: Definition of target weight, + and – tolerances in percent• Target values can be input using the keyboard or weighed• Different sizes of + and – tolerance can be used• When standard tolerances are used, only the target value is input or weighed. The effort is minimal and incorrect inputs are impossible.• Memory for 99 different articles and tolerances. Easy to call up and iden-tify! The display shows the number of the article memory at bottom right.• Secured against unauthorizedchanges! Individual functions, such as inputting and saving target val-ues, can be disabled for the user.• What do you prefer to see? The current weight, quantities or the deviation from the target weight? No problem! One simple input in theS etup menu is enough.• The “Take away” function allows repeated removal of a defined weight or quantity with automatic tolerance checking and automatic taring.The “Classify” function allows articles to be classified into up to five different classes.。

NA32-6kg称重传感器

NA32-6kg称重传感器

称重传感器台湾Mavin NA32称重传感器用途及特点计价秤Pricing Scale,计数秤Counting Scale,秤Weighing Scale,台秤Platform Scale。

台湾Mavin NA32称重传感器尺寸台湾Mavin NA32称重传感器技术参数额定容量5,20,30,40,50,75,100,200(公斤)量程型号:NA32-5kg,NA32-20kgNA32-30kg,NA32-40kg,NA32-50kgNA32-75kg,NA32-100kg,NA32-200kg额定输出2.0±在0.1mV/V非线性0.02%R.O.NA32-6kg迟滞0.02%R.O.重复性0.02%R.O.蠕变(30分钟)0.02%R.O.温度对产量0.002%R.O./℃温度对零点0.003%R.O./℃零点平衡±0.0200mV/V输入阻抗410±15Ω;1130±30Ω输出阻抗350±5Ω1000±10Ω绝缘阻抗≥5000MΩ/(50VDC)安全超载150%R.O.极限过载200%R.O.工作温度范围-20~60℃推荐的励磁5~12伏最大激励15VDC建筑铝合金防护等级IP66/IP67电缆φ5×1.5米平台尺寸350×450毫米连接红(EXC+),黑色(EXC-)的模式,绿色(SIG+),白色(SIG-)台湾Mavin NA32称重传感器应用过程注意事项对于小计量的NA32称重传感器和大计量的称重传感器安装的事项是不一样的,对于大计量的称重传感器它的要求比较多,就像电子地磅这样称重物体比较重的物体就应该在安装前对传感器小心谨慎,否则可能称重时所出现的问题很多。

如称重时会出现称重物体数值不准确,不稳定等等的因素,也会出现在使用一段时间之后导致罢工。

所以不仅对于电子秤的安装需要注意,还有称重传感器的安装更应该注意。

ILGB称重传感器

ILGB称重传感器

ILGB称重传感器ILGB称重传感器特性:◆可满足0.05kg-300kg量程范围内的测量。

◆铝合金材料,平行梁结构◆硅橡胶密封,表面阳极化,耐腐蚀性佳。

◆整体结构,安装使用方便。

◆适用于电子计价秤、电子平台秤等各类电子称重设备。

◆量程:0.05㎏到1000㎏◆高精度◆最大秤台尺寸450*450㎜以上内容技术参数以《OIML60号国际建议》92年版为基础,最新具体变化可查看《JJG669—12 Amcells广州南创传感器事业部检定规程》ILGB称重传感器产品图片ILGB称重传感器箱式结构ILC称重传感器:ILC-50kg称重传感器,ILC-75kg称重传感器,ILC-100kg称重传感器,ILC-120kg 称重传感器,ILC-150kg称重传感器,ILC-200kg称重传感器,ILC-250kg称重传感器,ILC-300kg称重传感器,ILC-500kg称重传感器,ILC-750kg。

ILCB称重传感器:ILCB-200kg称重传感器,ILCB-300kg称重传感器,ILCB-500kg称重传感器,ILCB-750kg称重传感器,ILCB-1000kg称重传感器,ILCB-1500kg。

IL称重传感器:IL-50kg称重传感器,IL-100kg称重传感器,IL-150kg称重传感器,IL-200kg称重传感器,IL-250kg称重传感器,IL-300kg称重传感器,IL-500kg称重传感器,IL-750kg称重传感器,IL-1000kg称重传感器,IL-1500kg称重传感器,IL-2000kg。

ILGB称重传感器:ILGB-50kg称重传感器,ILGB-100kg称重传感器,ILGB-200kg称重传感器,ILGB-250kg称重传感器,ILGB-500kg称重传感器,ILGB-750kg称重传感器,ILGB-1000kg称重传感器,ILGB-2000kg。

ILGB-A-50kg称重传感器,ILGB-A-100kg称重传感器,ILGB-A-200kg称重传感器,ILGB-A-250kg称重传感器,ILGB-A-500kg称重传感器,ILGB-A-750kg称重传感器,ILGB-A-1000kg称重传感器,ILGB-A-2000kg。

维萨拉湿度和温度传感器产品说明书

维萨拉湿度和温度传感器产品说明书

OrdererOrder no.MMT317 Moisture and Temperature Transmitter1234567891011121314151617 Vaisala HUMICAP® Moisture and Temperature Transmitter for Oil MMT310 7A2121. Probe code MMT317small pressure tight probe72. Transmitter type aw+T Faw+T+ppm for mineral transformer oil only M%RS + T + ppm mineral transformer oil only Paw+T+ppm**)specific transformer oil type:__________X3. Mounting Mounting plate (72.5 x 115 mm)54. Power supply no (24 VDC)A5. Signal output Analog output channel (Ch1&Ch2) 4... 20 mA & RS232C1Analog output channel (Ch1&Ch2)0... 20 mA & RS232C2Analog output channel (Ch1&Ch2) 1... 5 V & RS232C JAnalog output channel (Ch1&Ch2)0... 5 V & RS232C4Analog output channel (Ch1&Ch2)0... 10 V & RS232C56. Analog output signals Analog outputs disabled A A7. for Ch1 and Ch2Temperature (choose range in next section)C Caw (0...1)(0...1)T Tppm (0…100)(0…100)U U%RS (0..100)(0..100)W WSPECIAL:Define quantity for CH1:________________CH2:________________X XDefine scale for CH1:________________CH2:________________NOTE:- Choose A for both channels if you don't use analog outputs Ch1Ch28. Analog output range No range Afor temperature -60…+60°C(-76…140°F)B-40...+60°C(-40...+140°F)C-40...+120°C(-40...+248°F)D-40...+180°C(-40...+356°F)E-20...+60°C(-4...+140°F)F-20...+80°C(-4...+176°F)G-20...+120°C(-4...+248°F)HNOTE:0...+60°C(+32...+140°F)J- Choose A when T0...+100°C(+32...+ 212°F)Kis not desired special X9. Output units metric1non-metric210. Interface connection Connector (M12, 8-pin), no plug0Connector (M12, 8 pin) and plug with 5 m cable spare 5 m cable: 2121424Connector (M12, 8 pin) and plug with 10 m cable spare 10 m cable: 210964SP7Connector (M12, 8 pin) and plug with screw terminals511. Operating manual language no manual Aenglish see latest manual online: /mmt310B12. Probe with 0.5 m cable Xwith 2 m cable Pwith 5 m cable Qwith 10 m cable R13. Moisture sensor type special sensor for fluids spare: HUMICAP180L2214. Sensor protection in probe steinless steel grid (for applications with high flow speed, >1 m/s)spare: 220752SP Estainless steel grid (standard)spare: HM47453SP F15. Special features none116. Installation kit Swagelok ISO 1/2"spare: SWG12ISO12KSwagelok NPT 1/2"spare: SWG12NPT12NSwagelok ISO 3/8"spare: SWG12ISO38V 17. Calibration certificate calibration at room temperature standard service calibration: 2169892Selections in bold are included in the prices of the basic versions.Selections in italic are available at an extra price.Options and accessories:Example of order code with typical settings:238607USB Service cable1234567891011121314151617 ASM211103Rain Shield MMT3107F5A1C T K14B P2F1K2End customer:**) Check the availability and special delivery time from your local Vaisala representative.This model is always needed with silicone based transformer oils.OrdererOrder no.MMT318 Moisture and Temperature Transmitter1234567891011121314151617 Vaisala HUMICAP® Moisture and Temperature Transmitter for Oil MMT310 8A2121. Probe code MMT318for pressurized pipelines82. Transmitter type aw+T Faw+T+ppm for mineral transformer oil only M%RS + T + ppm mineral transformer oil only Paw+T+ppm**)specific transformer oil type:__________X3. Mounting Mounting plate (72.5 x 115 mm)54. Power supply no (24 VDC)A5. Signal output Analog output channel (Ch1&Ch2) 4... 20 mA & RS232C1Analog output channel (Ch1&Ch2)0... 20 mA & RS232C2Analog output channel (Ch1&Ch2) 1... 5 V & RS232C JAnalog output channel (Ch1&Ch2)0... 5 V & RS232C4Analog output channel (Ch1&Ch2)0... 10 V & RS232C56. Analog output signals Analog outputs disabled A A7. for Ch1 and Ch2Temperature (choose range in next section)C Caw (0...1)(0...1)T Tppm (0…100)(0…100)U U%RS (0..100)(0..100)W WSPECIAL:Define quantity for CH1:________________CH2:________________X XDefine scale for CH1:________________CH2:________________NOTE:- Choose A for both channels if you don't use analog outputs Ch1Ch28. Analog output range No range Afor temperature -60…+60°C(-76…140°F)B-40...+60°C(-40...+140°F)C-40...+120°C(-40...+248°F)D-40...+180°C(-40...+356°F)E-20...+60°C(-4...+140°F)F-20...+80°C(-4...+176°F)G-20...+120°C(-4...+248°F)HNOTE:0...+60°C(+32...+140°F)J- Choose A when T0...+100°C(+32...+ 212°F)Kis not desired special X9. Output units metric1non-metric210. Interface connection Connector (M12, 8-pin), no plug0Connector (M12, 8 pin) and plug with 5m cable spare 5 m cable: 2121424Connector (M12, 8 pin) and plug with 10 m cable spare 10 m cable: 210964SP7Connector (M12, 8 pin) and plug with screw terminals511. Operating manual language no manual Aenglish see latest manual online: /mmt310B12. Probe type226 mm probe with 2 m cable S226 mm probe with 5 m cable T226 mm probe with 10 m cable U448 mm probe with 2 m cable V448 mm probe with 5 m cable W448 mm probe with 10 m cable Z13. Moisture sensor type special sensor for fluids spare: HUMICAP180L2214. Sensor protection in probe stainless steel grid (for applications with high flow speed, >1 m/s)spare: 220752SP Estainless steel grid (standard)spare: HM47453SP F15. Special features none116. Installation kit ball valve set spare: BALLVALVE-1Efitting body ISO1/2, no leak screw spare: DRW212076SP Gfitting body NPT1/2, no leak screw spare: 212810SP H 17. Calibration certificate calibration at room temperature standard service calibration: 2169892Selections in bold are included in the prices of the basic versions.Selections in italic are available at an extra price.Options and accessories:Example of order code with typical settings:238607USB Service cable1234567891011121314151617 ASM211103Rain Shield MMT3108F5A1C T K14B S2F1E2End customer:**) Check the availability and special delivery time from your local Vaisala representative.This model is always needed with silicone based transformer oils.。

赛摩称重传感器说明书

赛摩称重传感器说明书

赛摩称重传感器说明书
用途与特点
一端固定,一端加载,密封良好;
受力后自动调心好,安装简单,使用方便,互换性好;
可用于制作各种超薄型电子汽车衡、单轨吊秤、料斗秤等。

量程
50,100,200,300,500kg;1,2,3,5,10,15,20t
悬臂梁称重传感器技术参数
额定载荷0.05~20t
综合精度0.020.03(线性+滞后+重复性)
灵敏度 2.0mV/V
蠕变±0.02%F·S/30min
零点输出±1%F·S
零点温度影响±0.02%F·S/10℃
输出温度影响±0.02%F·S/10℃
工作温度-20℃~+65℃
输入阻抗380±10Ω
输出阻抗350±3Ω
绝缘电阻〉5000MΩ
安全过载150%F·S
供桥电压建议10VDC
材质合金钢或不锈钢
接线方式输入(+):红线输入(-):黑线输出(+):绿线输出(-):白线
信号放大器接线电源:红公共端:绿输出:黄。

Interface传感器

Interface传感器

美国Interface传感器、Interface称重传感器、Interface悬臂梁式称重传感器、Interface柱式称重传感器、Interface轮辐式称重传感器、Interface拉压式称重传感器、Interface不锈钢称重传感器、Interface特殊称重传感器。

上海秋腾贸易有限公司特价代理美国Interface传感器、Interface称重传感器、Interface悬臂梁式称重传感器、Interface柱式称重传感器、Interface轮辐式称重传感器、Interface拉压式称重传感器、Interface不锈钢称重传感器、Interface特殊称重传感器
Interface 公司提供了全系列力传感器,扭矩传感器,仪器仪表,配件,以满足所有的力和扭矩传感器测量的需要。

当你需要一个测力、扭矩或者一个高精度的传感器,可以考虑选择Interface产品,它具有以下优点:
我们应用我们自己的专利合金技术生产独一无二的专利应变片。

安装有专利技术应变片的传感器,意味着具有更好的耐温性,较长的疲劳寿命和更高的输出电压(最多4mV/V)领先我们的竞争对手。

我们测试和校准每一个出厂的传感器-我们不是抽检。

你可以肯定你订购的传感器达到我们的设计指标和你的预期。

我们每个传感器都采用补偿技术。

使外界的干扰对传感器的影响最小化。

我们还对每个传感器进行蠕变测试,使其达到在业内最严密的规范。

Quality is our obsession!我们为质量不懈努力!。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

用途特點:台秤
Usage & Features :Platform scale 技術參數 Specification
額定負荷Rated Capacities 60,100,200,250,300,
500,800(kg )
額定輸出Rated Output 2.0 mV/V±5%零點平衡Zero Balance ±0.0200 mV/V 非線性Non-linearity 0.02 %R.O.滯後Hysteresis 0.02 %R.O.重復性Repeatability 0.02 %R.O.蠕變(30分鍾)30mins Creep 0.02 %R.O.回零(30分鍾)30mins Return 0.02 %R.O.安全過載率Safe Overload 150 %R.O.極限過載率Ultimate Overload
200 %R.O.輸出溫度影響Temperature Effect On Output 0.002 %R.O./℃零點溫度影響Temperature Effect On Zero 0.003 %R.O./℃輸入阻抗Input Impedance 410±15 Ω輸出阻抗Output Impedance 350±5 Ω絕緣阻抗Insulation Impedance ≥5000 MΩ/(50VDC)
推薦工作電壓Recommended Excitation 5~12 VDC 最大工作電壓Maximum Excitation
15 VDC 工作溫度範圍Operating Temperature Range -20~60 ℃材質Construction 鋁合金Aluminum Alloy
防護等級Protection Class IP66 / IP67電纜Cable
φ5×2m
推薦台面尺寸Recommended Platform Size 500×600 mm ;600×600 mm
接線方式Mode of Connection
紅:電源+,黑:電源-,綠:信號+,白:信號-Red (EXC+),Black (EXC-),Green (SIG+),White (SIG-)
主视(Front View)
广州南创电子科技有限公司。