gamma-secretase modulator 1_1172637-87-4_CoA_MedChemExpress
Naglazyme(galsulfase)(抗生物)商品说明书
Naglazyme® (galsulfase)(Intravenous)Document Number: MH-0084 Last Review Date: 02/01/2022Date of Origin: 11/28/2011Dates Reviewed: 12/2011, 02/2013, 02/2014, 12/2014, 10/2015, 10/2016, 10/2017, 10/2018, 02/2019,02/2020, 02/2021, 02/2022I.Length of AuthorizationCoverage will be provided for 12 months and may be renewed.II.Dosing LimitsA.Quantity Limit (max daily dose) [NDC Unit]:•Naglazyme 5 mg vial: 23 vials per 7 daysB.Max Units (per dose and over time) [HCPCS Unit]:•115 billable units every 7 daysIII.Initial Approval Criteria 1Coverage is provided in the following conditions:•Patient is at least 5 years of age; AND•Documented baseline 12-minute walk test (12-MWT), 3-minute stair climb test (3-MSCT), and/or pulmonary function tests (e.g., FEV1, etc.); AND•Documented baseline value for urinary glycosaminoglycan (uGAG); ANDMucopolysaccharidosis VI (MPS VI, Maroteaux-Lamy syndrome) † Ф1,4,5•Patient has a definitive diagnosis of MPS VI as confirmed by the following:o Detection of pathogenic mutations in the ARSB gene by molecular genetic testing; ORo Arylsulfatase B (ASB) enzyme activity of <10% of the lower limit of normal in cultured fibroblasts or isolated leukocytes; AND▪Patient has normal enzyme activity of a different sulfatase (excluding patients with Multiple Sulfatase Deficiency [MSD]); AND▪Patient has an elevated urinary glycosaminoglycan (uGAG) level (i.e. dermatan sulfate or chondroitin sulfate) defined as being above the upper limit of normal bythe reference laboratory†FDA-approved indication(s); ‡Compendia recommended indication(s); ФOrphan DrugIV.Renewal Criteria 1,4,5Coverage can be renewed based on the following criteria:•Patient continues to meet indication-specific relevant criteria such as concomitant therapy requirements (not including prerequisite therapy), performance status, etc. identified insection III; AND•Absence of unacceptable toxicity from the drug. Examples of unacceptable toxicity include: anaphylaxis and hypersensitivity reactions, immune-mediated reactions, acute respiratorycomplications associated with administration, acute cardiorespiratory failure, severeinfusion reactions, spinal or cervical cord compression, etc.; AND•Disease response with treatment as defined by improvement or stability from pre-treatment baseline by the following:o Reduction in uGAG levels; AND▪Improvement in or stability of 12-minute walk test compared (12-MWT); OR▪Improvement in or stability of 3-minute stair climb test (3-MSCT); OR▪Improvement in or stability of pulmonary function testing (e.g., FEV1, etc.)V.Dosage/Administration 1Indication DoseMucopolysaccharidosis VI(MPS VI, Maroteaux-Lamy Syndrome) 1 mg/kg administered as an intravenous (IV) infusion oncea weekVI.Billing Code/Availability InformationHCPCS Code:•J1458 – Injection, galsulfase, 1 mg; 1 billable unit = 1 mgNDC:•Naglazyme 5 mg per 5 mL solution; single-use vial: 68135-0020-xxVII.References1.Naglazyme [package insert]. Novato, CA; BioMarin Pharmaceutical Inc.; December 2019.Accessed January 2022.2.Giugliani R, Harmatz P, Wraith JE. Management guidelines for mucopolysaccharidosis VI.Pediatrics. 2007 Aug;120(2):405-18.3.Giugliani R, Federhen A, Rojas MV, et al. Mucopolysaccharidosis I, II, and VI: Brief reviewand guidelines for treatment. Genet Mol Biol. 2010 Oct;33(4):589-604. Epub 2010 Dec 1.4.Vairo F, Federhen A, Baldo G, et al. Diagnostic and treatment strategies inmucopolysaccharidosis VI. Appl Clin Genet. 2015 Oct 30;8:245-55.5.Valaannopoulos V, Nicely H, Harmatz P, et al. Mucopolysaccharidosis VI. Orphanet J RareDis. 2010; 5: 5.6.Harmatz P, Giugliani R, Schwartz I, et al. Enzyme replacement therapy formucopolysaccharidosis VI: a phase 3, randomized, double-blind, placebo-controlled,multinational study of recombinant human N-acetylgalactosamine 4-sulfatase(recombinant human arylsulfatase B or rhASB) and follow-on, open-label extension study. JPediatr. 2006 Apr;148(4):533-539.Appendix 1 – Covered Diagnosis CodesICD-10 ICD-10 DescriptionE76.29 Other mucopolysaccharidosesAppendix 2 – Centers for Medicare and Medicaid Services (CMS)Medicare coverage for outpatient (Part B) drugs is outlined in the Medicare Benefit Policy Manual (Pub. 100-2), Chapter 15, §50 Drugs and Biologicals. In addition, National CoverageDetermination (NCD), Local Coverage Determinations (LCDs), and Local Coverage Articles (LCAs) may exist and compliance with these policies is required where applicable. They can be found at: https:///medicare-coverage-database/search.aspx. Additional indications may be covered at the discretion of the health plan.Medicare Part B Covered Diagnosis Codes (applicable to existing NCD/LCD/LCA): N/AMedicare Part B Administrative Contractor (MAC) JurisdictionsJurisdiction Applicable State/US Territory ContractorE (1) CA, HI, NV, AS, GU, CNMI Noridian Healthcare Solutions, LLCF (2 & 3) AK, WA, OR, ID, ND, SD, MT, WY, UT, AZ Noridian Healthcare Solutions, LLC5 KS, NE, IA, MO Wisconsin Physicians Service Insurance Corp (WPS)6 MN, WI, IL National Government Services, Inc. (NGS)H (4 & 7) LA, AR, MS, TX, OK, CO, NM Novitas Solutions, Inc.8 MI, IN Wisconsin Physicians Service Insurance Corp (WPS) N (9) FL, PR, VI First Coast Service Options, Inc.J (10) TN, GA, AL Palmetto GBA, LLCM (11) NC, SC, WV, VA (excluding below) Palmetto GBA, LLCNovitas Solutions, Inc.L (12) DE, MD, PA, NJ, DC (includes Arlington &Fairfax counties and the city of Alexandria in VA)K (13 & 14) NY, CT, MA, RI, VT, ME, NH National Government Services, Inc. (NGS)15 KY, OH CGS Administrators, LLC。
Canon Cartridge 054 H Black 安全数据表说明书
SECTION 1: Identification of the substance/mixture and of the company/undertaking1.1. Product Identifier Product name Canon Cartridge 054 H Black Product Code(s)3028C0021.2. Relevant identified uses of the substance or mixture and uses advised against UseToner for electrophotographic machines1.3. Details of the supplier of the safety data sheet Supplier ImporterCanon Europa N.V.Bovenkerkerweg 59, 1185XB Amstelveen, The Netherlands +31 20 5458545, +31 20 5458222Manufacturer Canon Inc.30-2, Shimomaruko 3-Chome, Ohta-ku, Tokyo 146-8501, Japan 1.4. Emergency Telephone Number *1 Kontakt Giftlinien på tlf.nr.: 82 12 12 12 (åbent 24 timer i døgnet). Se punkt 4 om førstehjælp.*2 Only for the purpose of informing medical personnel in cases of acute intoxications.*3 Ask for Poison InformationSECTION 2: Hazards identification2.1. Classification of the substance or mixtureClassification according to Regulation (EC) No 1272/2008Not classified2.2. Label ElementsLabelling according to Regulation (EC) No 1272/2008112Safety Data SheetMalta 112Bulgaria Netherlands +31 (0)30-2748888 [*2]112Poland 112Version : 01Portugal +351 808 250 143CroatiaRomania +40 21 318 36 06+385 (0)1-23-48-342Slovakia +421 2 5477 4166Slovenia 112Cyprus Spain1121401Sweden 112 [*3]Issuing date : 02-Nov-2018United Kingdom 111 (UK only)Czech Republic Iceland 112+420 224919293Liechtenstein 145Norway+47 22 59 13 00Denmark Switzerland145+45 82 12 12 12 [*1]Estonia 16662SDS # : TCW 1791 N - 01 EU ENFinland +358 (0)9 471977France +33 (0)1 45 42 59 59Greece +30 210 7793777Austria Hungary +36 80 20 11 99+43 (0) 1 406 43 43Italy+39 (0)55 7947819Revision date : -Latvia+371 67042473Belgium Lithuania +370 687 53378+32 (0) 70 245 245LuxembourgHazard pictogramsNot requiredSignal wordNot requiredHazard statementsNot requiredPrecautionary statementsNot requiredOther InformationNone2.3. Other HazardsNoneSECTION 3: Composition/information on ingredients 3.2. MixturesChemical name CAS-No EC-No REACH registrationnumber Weight %Classification (Reg.1272/2008)Note toOtherHazardsStyrene acrylate copolymer CBI CBI None75 - 85NoneWax CBI CBI None 5 - 10NoneCarbon black1333-86-4215-609-9CBI 5 - 10NoneAmorphous silica7631-86-9231-545-401-2119379499-16-xxxx 1 - 3NoneFull texts of Hazard statement(s) are listed in SECTION 16Note to Other Hazards : The following substance(s) is (are) marked with (1), (2) and/or (3)- (1) Substance for which EU Occupational Exposure Limit(s) is (are) established (See SECTION 8)- (2) PBT substance or vPvB substance under Regulation (EC) No 1907/2006- (3) Substance listed in Candidate List of SVHC for Authorisation under Regulation (EC) No 1907/2006SECTION 4: First aid measures4.1. Description of first aid measuresInhalation Move to fresh air. Get medical attention immediately if symptoms occur.Ingestion Rinse mouth. Drink 1 or 2 glasses of water. Get medical attention immediately if symptomsoccur.Skin Contact Wash off immediately with soap and plenty of water. Get medical attention immediately ifsymptoms occur.Eye Contact Flush with plenty of water. Get medical attention immediately if symptoms occur.4.2. Most important symptoms and effects, both acute and delayedInhalation None under normal use. Exposure to excessive amounts of dust may cause physicalirritation to respiratory tract.Ingestion None under normal use.Skin Contact None under normal use.Eye Contact None under normal use. May cause slight irritation.Chronic Effects None under normal use. Prolonged inhalation of excessive amounts of dust may cause lungdamage.4.3. Indication of any immediate medical attention and special treatment neededNoneSECTION 5: Firefighting measures5.1. Extinguishing mediaSuitable extinguishing mediaUse CO 2, water, dry chemical, or foam.Unsuitable extinguishing mediaNone5.2. Special hazards arising from the substance or mixtureSpecial HazardMay form explosive mixtures with air.Hazardous combustion productsCarbon dioxide (CO 2), Carbon monoxide (CO)5.3. Advice for firefightersSpecial protective equipment for fire-fightersNoneSECTION 6: Accidental release measures6.1. Personal precautions, protective equipment and emergency proceduresAvoid breathing dust. Avoid contact with skin, eyes and clothing.6.2. Environmental PrecautionsKeep out of waterways.6.3. Methods and material for containment and cleaning upClean up promptly by scoop or vacuum. If a vacuum cleaner is used, be sure to use a model with dust explosion safety measures. May form explosive mixtures with air.6.4. Reference to other sectionsNoneSECTION 7: Handling and storage7.1. Precautions for safe handlingAvoid breathing dust. Avoid contact with skin, eyes and clothing. Clean contaminated surface thoroughly. Use only with adequate ventilation.7.2. Conditions for safe storage, including any incompatibilitiesKeep in a dry, cool and well-ventilated place. Keep out of the reach of children. Incompatible with oxidizing agents.7.3. Specific end usesToner for electrophotographic machines. Obtain special instructions before use.SECTION 8: Exposure controls/personal protection8.1. Control parametersExposure LimitsChemical name EU OEL Austria Belgium Bulgaria Cyprus Carbon black1333-86-4None None TWA: 3.5 mg/m3None NoneAmorphous silica 7631-86-9None TWA: 4 mg/m3inhalable fractionNone None NoneChemical name Czech Republic Denmark Finland France GermanyCarbon black 1333-86-4TWA: 2.0 mg/m3 dust TWA: 3.5 mg/m3TWA: 3.5 mg/m3STEL: 7 mg/m3TWA: 3.5 mg/m3NoneAmorphous silica 7631-86-9TWA: 4.0 mg/m3amorphous SiO2None TWA: 5 mg/m3None TRGS TWA: 4 mg/m3inhalable fractionDFG TWA: 4 mg/m3inhalable fractionChemical name Greece Hungary Ireland Italy NetherlandsCarbon black 1333-86-4TWA: 3.5 mg/m3STEL: 7 mg/m3None TWA: 3.5 mg/m3STEL: 7 mg/m3None NoneAmorphous silica 7631-86-9None None TWA: 6 mg/m3 totalinhalable dustTWA: 2.4 mg/m3respirable dustSTEL: 18 mg/m3 totalinhalable dustSTEL: 7.2 mg/m3respirable dustNone NoneChemical name Poland Portugal Romania Slovakia SpainCarbon black 1333-86-4TWA: 4.0 mg/m3 totalinhalable dustTWA: 3.5 mg/m3None TWA: 2 mg/m3respirable fraction, 5%or less fibrogeniccomponentTWA: 10 mg/m3respirable fraction,greater than 5%fibrogenic componentTWA: 10 mg/m3 totalaerosolTWA: 3.5 mg/m3Amorphous silica 7631-86-9None None None TWA: 4.0 mg/m3 totalaerosolNoneChemical name Sweden United Kingdom Norway Switzerland TurkeyCarbon black 1333-86-4TLV: 3 mg/m3 totaldustTWA: 3.5 mg/m3STEL: 7 mg/m3TWA: 3.5 mg/m3STEL: 3.5 mg/m3None NoneAmorphous silica 7631-86-9None TWA: 6 mg/m3inhalable dustTWA: 2.4 mg/m3respirable dustTWA: 1.5 mg/m3respirable dustSTEL: 1.5 mg/m3respirable dustTWA: 4 mg/m3inhalable dust, alsomanufactured in wetprocessingNone8.2. Exposure controlsAppropriate engineering controls None under normal use conditions. Individual protection measures, such as personal protective equipment Eye/face Protection Not required under normal use.Respiratory Protection Not required under normal use.Thermal hazardsNot ApplicableSECTION 9: Physical and chemical properties9.1. Information on basic physical and chemical properties Appearance Black ; powder OdorSlight odorOdor threshold No data available pHNot ApplicableEvaporation RateNot ApplicableFlammability (solid, gas)Not flammable; estimatedFlammability Limits in AirUpper Flammability Limit Not Applicable Lower Flammability Limit Not Applicable Vapor pressure Not Applicable Vapor density Not Applicable Relative density 1.0 - 1.2Solubility(ies)Organic solvent; partly soluble Partition coefficient: n-octanol/water Not Applicable Explosive properties May form explosive mixtures with air Oxidizing properties No data available9.2. Other Information No data availableSECTION 10: Stability and reactivity10.1. Reactivity None10.2. Chemical stability Stable10.3. Possibility of Hazardous Reactions None10.4. Conditions to Avoid None10.5. Incompatible materialsAcids, Bases, Oxidizing agents, Reducing agents.10.6. Hazardous Decomposition Products Carbon dioxide (CO 2), Carbon monoxide (CO)Melting/Freezing point (°C)Autoignition Temperature (°C)No data available 80 - 130 (Softening point)Decomposition Temperature (°C)> 200Boiling Point/Range (°C)Viscosity (mPa s)Not ApplicableNot Applicable Flash Point (°C)Not ApplicableSECTION 11: Toxicological information11.1. Information on toxicological effectsAcute toxicity Estimate: LD50 > 2000 mg/kg (Ingestion)Skin corrosion/irritation Estimate: Non-irritantSerious eye damage/eye irritation Estimate: Transient slight conjunctival irritation only.Sensitization Estimate: Non-sensitizingGerm cell mutagenicity Ames Test (S. typhimurium, E. coli): NegativeCarcinogenicity The IARC evaluated carbon black as a Group 2B carcinogen, for which there is inadequatehuman evidence, but sufficient animal evidence. The latter is based upon the developmentof lung tumors in rats receiving chronic inhalation exposure to powdered carbon black atlevels that induce particle overload of the lung.However, there is a two-year inhalation study of a toner containing carbon black whichdemonstrated no association between toner exposure and tumor development in rats. Reproductive Toxicity No data availableSTOT - single exposure No data availableSTOT - repeated exposure Muhle et al. reported pulmonary response upon chronic inhalation exposure in rats to atoner enriched in respirable-sized particles compared to commercial toner. No pulmonarychange was found at 1 mg/m3 which is most relevant to potential human exposure. Aminimal to mild degree of fibrosis was noted in 22% of the animals at 4 mg/m3, and a mildto moderate degree of fibrosis was observed in 92% of the animals at 16 mg/m3.These findings are attributed to "lung overloading", a generic response to excessiveamounts of any dust retained in the lung for a prolonged interval.Aspiration hazard No data availableOther Information No data availableSECTION 12: Ecological information12.1. ToxicityEcotoxicity effectsEstimate: Fish, 96h LC50 > 100 mg/lEstimate: Crustaceans, 48h EC50 > 100 mg/lEstimate: Algae, ErC50(0-72h) > 100 mg/l12.2. Persistence and degradabilityNo data available12.3. Bioaccumulative potentialNo data available12.4. Mobility in soilNo data available12.5. Results of PBT and vPvB assessmentThis preparation contains no substance considered to be persistent, bioaccumulating nor toxic (PBT).This preparation contains no substance considered to be very persistent nor very bioaccumulating (vPvB).12.6. Other adverse effects No data availableSECTION 13: Disposal considerations13.1. Waste treatment methodsDO NOT put toner or a toner container into fire. Heated toner may cause severe burns. DO NOT dispose of a toner container in a plastic crusher. Use a facility with dust explosion prevention measures. Finely dispersed particles form explosive mixtures with air.Dispose of in accordance with local regulations.SECTION 14: Transport informationSECTION 15: Regulatory information15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture (EC) No 1907/2006 Authorisation Not regulated (EC) No 1907/2006 Restriction Not regulated (EC) No 1005/2009Not regulated (EC) No 850/2004Not regulated (EU) No 649/2012Not regulated Other InformationNone15.2. Chemical safety assessment NoneSECTION 16: Other informationKey literature references and sources for data- World Health Organization International Agency for Research on Cancer, IARC Monographs on the Evaluation on the Carcinogenic Risk of Chemicals to Humans- EU Regulation (EC) No 1907/2006, (EC) No 1272/2008, (EC) No 1005/2009, (EC) No 850/2004, (EU) No 649/2012None 14.7. Transport in bulk according to Annex II of MARPOL and the IBC CodeNot Applicable 14.3. Transport Hazard Class 14.1. UN numberNone None 14.4. Packing Group None14.5. Environmental Hazards Not classified as environmentally hazardous under UN Model Regulations and marine pollutant under IMDG Code.14.2. UN Proper Shipping Name 14.6. Special Precautions for usersIATA: Not regulatedKey or legend to abbreviations and acronyms used in the safety data sheet- PBT: Persistent, Bioaccumulative and Toxic- vPvB: very Persistent and very Bioaccumulative- SVHC: Substances of Very High Concern- EU OEL: Occupational exposure limits at Union level under Directive 2004/37/EC and (EU) 2017/2398, 98/24/EC, 91/322/EEC, 2000/39/EC, 2006/15/EC, 2009/161/EU and (EU) 2017/164.- TWA: Time Weighted Average- STEL: Short Term Exposure Limit- IARC: International Agency for Research on Cancer- IATA: International Air Transport Association- CBI: Confidential Business InformationIssuing date :02-Nov-2018Revision date :-Revision Note NoneThis safety data sheet (SDS) is supplied voluntarily.DisclaimerThe information provided on this SDS is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.。
N-(β-氨乙基-γ-氨丙基)甲基二甲氧基硅烷(SDS)安全数据单
六、意外释放措施
人身防范、保护设备和应急程序:避免接触皮肤及眼睛。避免吸入气雾,保持容器密封。 环境防范措施:用任何方法防止泄漏物进入阴沟或排水道。在安全的前提下,阻止泄漏。 抑制和清理的方法和材料:小量泄漏:用沙子、土、惰性物质或蛭石来收集并吸附泄漏物。用抹布 擦除。收集泄漏物于贴有相应标签的容器中,以便废弃处理。大量泄漏,尽可能的回收利用用沙子、 土或蛭石收集泄漏物。收集可回收的产品于贴有标签的容器中,以便回收利用。对残留物进行中和/ 去污。收集固体残留物,密封于贴有标签的桶中,以便废弃处理。冲洗沾染区域,防止废液流入阴 沟。完成清理工作后,对所有防护服和设备,在存放和再使用前,应进行去污和清洗。如果阴沟或 排水道被污染,报告应急处理部门。
參考文献
十六、其它信息
联合国《关于危险货物运输的建议书.规章范本》 联合国《全球化学品统一分类和标签制度》
制表日期
2012 年 03 月 14 日
注 1:当产品为含有两种以上危险物质的混合物时,应依据其混合后的危险性,制作安全数据单。 注 2:制造商/供应商应根据实际情况确保安全数据单所含信息的正确性,并适时更新。 注 3:如由于产品特性而不存在或不可得某些信息时(如固体不存在沸点),应在表格中以“/”标识。
九、物理及化学性质
无色或浅黄色透明液体 刺激性气味 / 10.6(10 g/L 20℃) <0℃ 265℃ 大于 90 ℃ / / / / 7.1 0.968±0.0050 g/cm3 遇水水解 / / / /
十、稳定及反应性
反应性:/ 化学稳定性:室温下稳定 危险反应的可能性:不能发生危险的聚合反应 应避免的条件:潮湿空气 不相容的物质和材料:强氧化剂、酸类 危险的分解产物:/
化学名称
12 taiyo yuden 产品使用注意事项说明书
Notice for TAIYO YUDEN products Please read this notice before using the TAIYO YUDEN products.■ Product information in this catalog is as of October 2011. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully be-fore practical application or usage of the Products.Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorpo-rating such products, which are caused under the conditions other than those specified in this catalog or individual specification.■ Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available.■ Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment.■ All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance.Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, subma-rine system, military, etc. where higher safety and reliability are especially required.In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliabil-ity evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage.■ The contents of this catalog are applicable to the products which are purchased from our sales offices or distribu-tors (so called “TAIYO YUDEN’s official sales channel”).It is only applicable to the products purchased from any of TAIYO YUDEN’ s official sales channel.■ Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may oc-cur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights.■ Caution for exportCertain items in this catalog may require specific procedures for export according to “Foreign Exchange and For-eign Trade Control Law”of Japan, “U.S. Export Administration Regulations”, and other applicable regulations.Should you have any question or inquiry on this matter, please contact our sales staff.notice_e-0176mlci03_e-01■ FEATURES■ ORDERING CODE■ EXTERNAL DIMENSIONS/STANDARD QUANTITY■ APPLICATIONS■ AVAILABLE INDUCTANCE RANGE* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.◦ L ow profile below 1.2mm.◦ L ow Rdc.◦ M ultilayer block Structure yields higher reliability.◦ N ew line up NM series improved in inductance temperature character-istic based on current CK series P type.◦ D C/DC converter for the Mobile equipment; Cellular Phones,DSC, DVC.MULTILAYER CHIP POWER INDUCTORS (CK SERIES P TYPE / NM SERIES )C KP 2520V1R0M -T ○REFLOW77mlci03_e-01INDUCTORSPOWER INDUCTORS■ PART NUMBERS* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs. ●CKP2012●CKP2016●CKP2520●NM2012●NM252078mlci03_e-01■ ELECTRICAL CHARACTERISTICS * This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.INDUCTORSPOWER INDUCTORS*This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.79mlci03_e-01mlci0109_reli-PRP1mlci0109_reli_e-01* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.◦Tape & Reel Packaging①Minimum Quantity ②Taping material◦Paper tape (0.315 inches wide)③Taping Dimensions(inch )To next page C K 2125C K S 2125C K P 2012C K P 2016C K P 2520N M 2012N M 2520L K 2125H K 2125B K 2125B K3216C K1608C K 2125C K S 2125L K 1005L K 1608L K 2125H K 0402H K 0603H K 1005H K 1608H K Q 0603A Q 105B K 0402B K 0603B K 1005B K 1608B K 2125B K 2010B K P 0603B K P 1005B K P 1608B K P 2125B K H 1005mlci0109_reli-PRP2mlci0109_reli_e-01* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs. (inch )◦Embossed Tape (0.315 inches wide)④LEADER AND BLANK PORTIONDirection of tape feed15.7inches or more⑤Reel Size⑥Top tape strengthThe top tape requires a peel-off force of 0.1~0.7N in the direction of the arrow asillustrated below.mlci0109_reli-PRP3mlci0109_reli_e-01* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.mlci0109_reli-PRP4mlci0109_reli_e-01* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs. Definition of rated current :・In the CK, CKS and BK Series, the rated current is the value of current at which the temperature of the element is increased within 20℃.・In the BK Series P type and CK Series P type, NM Series the rated current is the value of current at which the temperature of the element is increased within 40℃.・In the LK,HK,HKQ,and AQ Series, the rated current is either the DC value at which the internal L value is decreased within 5% with the application of DC bias, or the value of current at which the temperature of the element is increased within 20℃.BK0402 SeriesMeasuring frequency :100±1MHz Measuring equipment :E4991A (or its equivalent )Measuring jig :16196D (or its equivalent )BK0603 Series, BKP0603 Series Measuring frequency :100±1MHz Measuring equipment :4291A (or its equivalent )Measuring jig :16193A (or its equivalent )BK1005 Series, BKP1005 Series, BKH1005 Series Measuring frequency :100±1MHz Measuring equipment :4291A (or its equivalent )Measuring jig :16192A (or its equivalent ), 16193A (or its equivalent )BK1608・2125 Series, BKP1608・2125 SeriesMeasuring frequency :100±1MHz Measuring equipment :4291A (or its equivalent ), 4195A (or its equivalent )Measuring jig :16092A (or its equivalent ) or 16192A (or its equivalent )/HW BK2010・3216 SeriesMeasuring frequency :100±1MHz Measuring equipment :4291A (or its equivalent ) , 4195A (or its equivalent ) Measuring jig :16192A (or its equivalent )mlci0109_reli-PRP5mlci0109_reli_e-01* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.CK Series :Measuring frequency :2 to 4MHz (CK1608)Measuring frequency :2 to 25MHz (CK2125)Measuring frequency :2 to 10MHz (CKS2125)LK Series :Measuring frequency :10 to 25MHz (LK1005) Measuring frequency :1 to 50MHz (LK1608) Measuring frequency :0.4 to 50MHz (LK2125)CKP Series, NM Series :Measuring frequency :1MHz (CKP2012, CKP2016, CKP2520, NM2012・NM2520)Measuring equipment, jig :・4194A +16085B +16092A (or its equivalent )・4195A +41951+16092A (or its equivalent )・4294A +16192A (or its equivalent )・4291A +16193A (or its equivalent )/LK1005・4285A +42841A +42842C +42851-61100(CKP2012・CKP2016・CKP2520・NM2012・NM2520)Measuring current :・1mA rms (0.047 to 4.7μH ) ・0.1mA rms (5.6 to 33μH )HK 、HKQ 、AQ Series :Measuring frequency :100MHz (HK0402・HK0603・HK1005・AQ105)Measuring frequency :50/100MHz (HK1608・HK2125)Measuring frequency :500MHz (HKQ0603S ・HKQ0603U )Measuring equipment, jig :・4291A +16197A (or its equivalent )/HK0603・AQ105・4291A +16193A (or its equivalent )/HK1005 ・E4991A +16197A (or its equivalent )/HKQ0603S ・HKQ0603U ・4291A +16092+in-house made jig (or its equivalent )/HK1608・HK2125・E4991A +16196D (or its equivalent )/HK0402Measuring equipment :VOAC-7412(made by Iwasaki Tsushinki ) VOAC-7512(made by Iwasaki Tsushinki )CK Series :Measuring frequency :2 to 4MHz (CK1608)Measuring frequency :2 to 25MHz (CK2125)LK Series :Measuring frequency :10 to 25MHz (LK1005)Measuring frequency :1 to 50MHz (LK1608)Measuring frequency :0.4 to 50MHz (LK2125)Measuring equipment, jig :・4194A +16085B +16092A (or its equivalent )・4195A +41951+16092A (or its equivalent )・4294A +16192A (or its equivalent )・4291A +16193A (or its equivalent )/LK1005Measuring current :・1mA rms (0.047 to 4.7μH ) ・0.1mA rms (5.6 to 33μH )HK 、HKQ 、AQ Series :Measuring frequency :100MHz (HK0603・HK1005・AQ105)Measuring frequency :50/100MHz (HK1608・HK2125)Measuring frequency :500MHz (HKQ0603S ・HKQ0603U )Measuring equipment, jig : ・4291A +16197A (or its equivalent )/HK0603・AQ105・4291A +16193A (or its equivalent )/HK1005・E4991A +16197A (or its equivalent )/HKQ0603S ・HKQ0603U ・4291A +16092A + in-house made jig (or its equivalent )/HK1608・HK2125・E4991A +16196D (or its equivalent )HK0402LK Series:Measuring equipment:4195A(or its equivalent)Measuring jig:41951+16092A(or its equivalent)HK、HKQ、AQ Series:Measuring equipment:8719C(or its equivalent)・8753D(or its equivalent)/HK2125Reference temperature:+20℃Testing board:glass epoxy-resin substrate0.8mmThickness:Solder temperature:230±5℃Duration:4±1 sec.Solder temperature:260±5℃Duration:10±0.5 sec.Preheating temperature:150 to 180℃Preheating time:3 min.Flux:Immersion into methanol solution with colophony for 3 to 5 sec.Recovery:2 to 3 hrs of recovery under the standard condition after the test.(See Note 1)Step 1:Minimum operating temperature+0-3℃ 30±3 min.Step 2:Room temperature 2 to 3 min.Step 3:Maximum operating temperature+3-0℃ 30±3 min.Step 4:Room temperature 2 to 3 min.Number of cycles:5Recovery:2 to 3 hrs of recovery under the standard condition after the test.(See Note 1)(Note 1) When there are questions concerning mesurement result;measurement shall be made after 48±2 hrs of recovery under the standard condition.BK, BKP, BKH Series:Temperature:40±2℃Humidity:90 to 95%RHDuration:500+24-0hrsRecovery:2 to 3 hrs of recovery under the standard condition after the removal from test chamber.(See Note 1)LK、CK、CKS、CKP、NM、HK、HKQ、AQ Series:Temperature:40±2℃(LK、CK、CKS、CKP、NM Series):60±2℃(HK、HKQ、AQ Series)Humidity:90 to 95%RHDuration:500±12 hrsRecovery:2 to 3 hrs of recovery under the standard condition after the removal from test chamber.(See Note 1)BK, BKP, BKH Series:Temperature:40±2℃Humidity:90 to 95%RHApplied current:Rated currentDuration:500+24-0hrsRecovery:2 to 3 hrs of recovery under the standard condition after the removal from test chamber.(See Note 1)LK、CK、CKS、CKP、NM、HK、HKQ、AQ Series:Temperature:40±2℃(LK、CK、CKS、CKP、NM Series):60±2℃(HK、HKQ、AQ Series)Humidity:90 to 95%RHApplied current:Rated currentDuration:500±12 hrsRecovery:2 to 3 hrs of recovery under the standard condition after the removal from test chamber.(See Note 1)Note on standard condition: "standard condition" referred to herein is defined as follows:5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.When there are questions concerning measurement results:In order to provide correlation data, the test shall be conducted under condition of 20±2℃ of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.BK, BKH Series:Temperature:125±3℃Applied current:Rated currentDuration:500+24-0hrsRecovery:2 to 3 hrs of recovery under the standard condition after the removal from test chamber.(See Note 1)LK、CK、CKS、CKP、NM、HK、HKQ、AQ、BKP Series:Temperature:85±2℃(LK、CK、CKS、CKP、NM、BKP Series):85±2℃(HK1608,2125):85±2℃(HK1005, AQ105 operating temperature range -55 to +85℃):125±2℃(HK0402, HK0603, HK1005, HKQ0603S, HKQ0603U, AQ105 operating temperature range -55 to +125℃)Applied current:Rated currentDuration:500±12 hrsRecovery:2 to 3 hrs of recovery under the standard condition after the test.(See Note 1)Note on standard condition: "standard condition" referred to herein is defined as follows:5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.When there are questions concerning measurement results:In order to provide correlation data, the test shall be conducted under condition of 20±2℃ of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air pressure. Unless other-wise specified, all the tests are conducted under the "standard condition."(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.To next pagemlci0109_reli-PRP16mlci0109_reli_e-01■ PRECAUTIONS* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (/) or CD catalogs.Precautions on the use of Multilayer chip Inductors, Multilayer chip inductors for high frequency, Multilayer chip bead Inductors。
核苷类药物知识
核苷类药物知识核苷类药物的综述,免费下载的,大家给好评吧!O(∩_∩)O~1. 前言核苷和脱氧核苷是由核苷碱基分别和核糖或脱氧核糖以苷键形式而构成的,它们是组成核糖核酸(RNA)和脱氧核糖核酸(DNA)的基本元件,是遗传基因的基础。
核苷和脱氧核苷系列衍生物具有多种生物活性物质,可以直接或间接地作为药物使用,在治疗多种重大的疾病方面起到极其重要的作用,国外已经研究开发出系列化药物并商品化,国内研究与开发较晚,发展前景非常广阔.1。
1 核苷类药物的合成与生产从20世纪40年代末期,国外就开始核苷及其系列药物的合成与开发。
目前世界排名前25位制药大公司都有自己的核苷衍生物生产或加工厂,并且均有持有专利的核苷类药物上市,并且从20世纪90年代起投入巨资用于基因药物的研究。
据国外有关资料预计,2003年基因药物的市场价值将超过30亿美元.在亚洲,日本是最早开发核苷类药物和基因药物的国家,如武田、住友、味之素等公司均有相关的中间体开发机构和生产基地。
另外韩国、印度在20世纪90年代初开始投入这类产品的开发与生产.中国在核苷及其衍生物方面的开发研究与生产始于20世纪90年代末期,但是核苷及其中间体品种少,部分原料依赖进口,与目前快速发展的生命科学及相关药物研究不相适应。
1。
2 核苷类药物的应用核苷与脱氧核苷系列化合物主要用于医药领域,用途广泛,而且新产品层出不穷,应用范围不断扩大.(一)抗病毒药物。
核苷类抗病毒药物品种繁多,结构多样,主要以破坏病毒转录,干扰或终止病毒核酸的合成为目的,用于抗疱疹病毒、HIV、HBV、以及流感和呼吸系统病毒等DNA和RNA病毒。
目前在这方面应用最多,而且新出现的药物主要集中于治疗上述疾病。
(二)抗肿瘤药物。
目前用于临床和正在研究的核苷类抗肿瘤药物有数十种,它们的主要作用是干扰肿瘤的DNA合成,或者影响核酸的转录过程,抑制蛋白质的合成,从而达到治疗肿瘤的效果。
(三)抗真菌类药物.具有这方面作用的核苷类化合物已经有多种用于临床应用,其中有部分产品对多种真菌具有抑制作用,而且对哺乳动物几乎无毒性。
ZLB系列产品说明书
Material Safety Data Sheet*ZLB*SECTION 1 - PRODUCT IDENTIFICATION AND USEPRODUCT IDENTIFIER: 1Z-L, 8Z-L, 5B-LCATALOG NUMBERS: 99001123, 99001124, 99001125PRODUCT USE: Shaft Lubricant & Electrical Joint CompoundMANUFACTURERS NAME: Acheson Colloids Co. PHONE #: (810) 984-5581STREET ADDRESS: PO Box 77000 Dept. 771226CITY: Detroit STATE: Michigan ZIP CODE: 48277-1226DISTRIBUTORS NAME: TWECO Products, Inc. EMERGENCY PHONE #: (940) 566-2000STREET ADDRESS: 2800 Airport RoadCITY: Denton STATE: Texas ZIP CODE: 76207PREPARED BY: Terry Fulks PHONE NUMBER: (940) 566-2000 DATE PREPARED: October 31, 1990 DATE REVISED: January 31, 2007SECTION 2 - HAZARDOUS INGREDIENTSHAZARDOUS INGREDIENTS %/RANGE CAS NUMBER OSHA PEL ACGIH TLVGraphite(natural) 30 7782-42-5 15mppcf 2.5mg/m3 Mineral Oil 62+ 8012-95-1 5 mg/m3 5 mg/m3SECTION 313. SUPPLIER INFORMATIONTHIS PRODUCT DOES [ ] DOES NOT [X] CONTAIN TOXIC CHEMICALS SUBJECT TOTHE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING ANDCOMMUNITY RIGHT-TO-KNOW ACT OF 1986 AND OF 40 CFR 372.CAS NUMBER CHEMICAL NAME %SECTION 3 - PHYSICAL DATAPHYSICAL STATE: Liquid ODOR AND APPEARANCE: Black Paste With Mineral OilOdor VAPOR PRESSURE(mm Hg): N.Av. VAPOR DENSITY(air=1): N.Av.EVAPORATION RATE: N.Av. BOILING POINT(F/C): >600F FREEZING POINT(F/C): N.Av.pH: N.Av. SPECIFIC GRAVITY: 0.9 SOLUBILITY: NegligibleSECTION 4 - FIRE AND EXPLOSION DATAFLAMMABILITY: Yes [X] No [ ] IF YES, MEANS OF EXTINCTION: Foam, CO2, DryChemical FLASHPOINT(F/C) AND METHOD: 450F C.O.C. FLAMMABLE LIMIT: N.Av.LEL: N.Av. UEL: N.Av. UNUSUAL FIRE AND EXPLOSION HAZARDS: NoneN.App.: NON APPLICABLE; N.AV.: NOT AVAILABLE; N.EST.: NOT ESTABLISHEDN.F.P.A. RATING SYSTEM: 0 - INSIGNIFICANT; 1 - SLIGHT; 2 - MODERATE;3 - HIGH;4 - EXTREMEHealth = 1 Flammibility = 1 Reactivity = 0 Special = _WHMIS CLASSIFICATION: CLASS "D" DIVISION 2 SUB-DIVISION "B"SECTION 5 - REACTIVITY DATACHEMICAL STABILITY: Yes [X] No [ ] IF NO, CONDITIONS TO AVOIDINCOMPATIBILITY WITH OTHER SUBSTANCES: Yes [X] No [ ] IF YES, WHICHONES? May react vigorously with oxidizing materialsHAZARDOUS POLYMERIZATION: Will Occur [ ] Will Not Occur [X]CONDITIONS TO AVOID: None known HAZARDOUS DECOMPOSITION PRODUCTS: CO, CO2ZLB Page 2SECTION 6 - HEALTH HAZARD DATAROUTE OF ENTRY: SKIN CONTACT [ ] SKIN ABSORPTION [X] EYE CONTACT [X]INHALATION [X] INGESTION [ ]EFFECTS OF ACUTE/CHRONIC EXPOSURE TO PRODUCT: Irritation of the eyes,Dermatitis CARCINOGENICITY: No SIGNS AND SYMPTOMS OF EXPOSURE: Irritationof the skin and eyes MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Pre-existing skin disorders EMERGENCY AND FIRST AID PROCEDURES: SKIN: Washthoroughly with soap and water EYES: Flush immediately with water for15 minutes, get medical attention. INGESTION: No ill effects expectedINHALATION: No ill effects expectedSECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USELEAK AND SPILL PROCEDURE: Remove any source of ignition, scoop up as much aspossible, cover remainder with absorbent material & place in non-leakingcontainer for disposal. WASTE DISPOSAL METHOD: Dispose of in accordance withFederal, State & Local regulationsPRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: Store away from sparks, openflames, or excessive heatSECTION 8 - CONTROL MEASURESRESPIRATORY PROTECTION: Not needed for this product. As required for cuttingand welding. GLOVES: Oil resistant RESPIRATOR: not needed EYE: Safetyor chemical goggles FOOTWEAR: N.App. CLOTHING: As required for weldingOTHER: N.Est.VENTILATION: Not normally needed WORK/HYGIENIC PRACTICES: Normal HygieneREFERENCES:"Chemical Guide To OSHA Hazard Communication Standard" First Edition"Handbook Of Toxic And Hazardous Chemicals and Carcinogens" Second Edition "Registry Of Toxic Effects Of Chemical Substances""NIOSH Pocket Guide to CHEMICAL HAZARDS" June 1994THIS DATA IS OFFERED IN GOOD FAITH AS TYPICAL VALUES. THIS IS NEITHER ANEXPRESSED NOR IMPLIED PRODUCT SPECIFICATION. RECOMMENDED HANDLING PROCEDURESAND HYGIENE ARE BELIEVED TO BE ACCURATE, HOWEVER, THESE RECOMMENDATIONS SHOULDBE REVIEWED IN THE SPECIFIC CONTEXT OF INTENDED USE AND DETERMINED APPROPRIATEBY THE USER.。
三和激光功率计LP10说明书
•••••Thank you for purchasing SANWA laser power meter LP10.Read this manual carefully before use for safe use of the instrument. Retain this manual together with the instrument for future reference.[1] Operating PrecautionsDo not stare directly at the laser light or allow its reflections enter your eyes during measurement. Laser light incident to your eyes may lead to degradation or loss of eyesight. Special care is required for the IV light which is invisible for naked eyes.An excessive optical input may damage the photodiode in the light sensor. Do not apply light that is stronger than the measurable range .Be careful not to damage the light sensor surface or stain it by douching with a bare hand. Scratches or stain may deteriorate the sensitivity of the instrument. If the light sensor surface gets dirty, wipe lightly with ethyl alcohol.The auto power save function of the instrument turns it off in 15 minutes after an operation. To resume the meter from auto power save status, press MAX/MIN button or turn the Range switch off position, then turn off the power.Be sure to set the Power/Range switch to OFF after use.This instrument is a pocket-sized laser power meter featuring excellent portability and operability.It can be applied easily in check and maintenance of the optical power levels of equipment using laser light.Using 633 nm of a He-Ne laser as the reference wavelength, this instrument enables direct reading of the optical power of visible-range laser light from a visible laser pointer, DVD player’s optical pickup, etc.The power of other wavelength can also be measured by converting the reading according to the spectral sensitivity characteristic table (typical values).The measured object is CW laser. A modulated laser cannot be measured accurately.[2] Applications[4] Nomenclature••••••••Pocket size.Separate light sensor probe can be integrated with the main body for measurement.4039 full-scale count with a bar graph display.Direct reading of the laser power of the reference wavelength of 633 nm, while the laser power of other wavelengths can be read by converting it according to the spectral sensitivity characteristic table.Wide measuring range from 0.01 μW to 40.39 mW.MIN/MAX hold functions.The diffusion sheets are used in the sensor, it can suppress the “return light” that is generated when a laser light enters the sensor.Auto power save function prevents wasting of battery power.[3] Features Push 2sPushMAX Hold MIN HoldMIN Hold mode:Holds the minimum value during measurement and displays it in the digital display. Indicated by “MIN” shown in the display.MAX Hold mode:Holds the maximum value during measurement and displays it in the digital display. Indicated by “MIN” shown in the display.••The bar graph display is not held.The MIN/MAX Hold mode is canceled when themeasurement range is changed.The auto power save function does not work inthe MIN/MAX Hold mode.Using the MAX Hold function makes it possible display always the maximum value measured. This solves the problem in the meter reading, that varies depending on the position, distance and angle of the incidence of laser beam into the light sensor surface.[5] FunctionsNotes)••••••Power/Range switchThis rotary switch is used to turn the illuminance meter on-off and switch the measurement range to the 40 μW, 400 μW, 4 mW or 40 mW range.Battery warning indicatorWhen the internal batteries are nearly exhausted and the supply voltage drops, blinking “BT” appears in the display. If this happens, please replace both batteries with new ones.MIN/MAX Hold button (Also used as the protection cover lock)Push this button during measurement to set the digital value display to the MAX Hold or MIN Hold mode as shown below.How to integrate the light sensor probe with the main body for measurementInsert the light sensor probe in the position on the top left of the main body as shown in the figure.How to open or close the protective coverTo open the protective cover, push and hold the button on the left side of main body into the direction shown in the figure, and open the protective cover.To close the protective cover, first store the light sensor probe in the storage position of the main body as described below, and then close the protective cover until it is locked.How to store the light sensor probeThe light sensor probe can be stored in the main body as shown below.into the storage position so that the light sensor surface faces up.in the space on the right of the light sensor probe.1.2.1.2.The auto power save function of the instrument turns it off in 15 minutes after an operation. To resume the meter from auto power save status, press MAX/MIN button or turn the Range switch off position, then turn off the power.When over range, displays "OL".Laser should be received on the center of the sensor at right angle.Measurement of weak laser power (below 1 mW) tends to be affected by ambient light (disturbance). In this case, it is required to take a countermeasure against disturbance, by performing measurement in a dark room.Notes)1.2.3.4.Measurement Procedure[6] Measurement••••Set the measuring range to the maximum range (40 mW).Apply the laser beam to the light sensor surface.After measuring the current power, set the measuring range to the optimum range.After completing measurement, set the Power/Range switch to OFF.How to correct the wavelength sensitivity of the light sensor The reference wavelength that can be read directly with this instrument is 633 nm. To measure light with wavelengths other than 633 nm, convert the reading using the sensitivity correction coefficient obtained from the photodiode’s spectral sensitivity characteristics (typical values).Reading Correction coefficient Wavelength-converted value 2.44 (mW) x 0.74 1.81 (mW)*This conversion value is a guide and is not guaranteed.When the measured laser light wavelength is 780 nm and the power meter reading is 2.44 mW:To maintain accuracy, perform calibration and inspection at least once an year.[7] Maintenance and Administration[8] After-Sale ServicingThe panel and case are little resistant to volatile solutions and heat. Do not wipe the thermometer using lacquer thinner or alcohol and do not place it heat a source of high temperatures (soldering iron, for example).Do not store the instrument in a place subject to vibrations or in a place which it may drop.Do not store the instrument under direct sunlight or in a place with low temperatures, high humidity or condensation.Be sure to remove the batteries when the instrument is not to be used for an extended period.For information of repair, please contact the dealer, selling agent or maker.4. StorageSet the Range switch to OFF, then remove the screw retaining the battery compartment cover using a screwdriver.Remove the battery compartment cover and take out the exhausted batteries.Insert new batteries without mistaking the + and – polarity.Attach the battery compartment cover and clamp it with the screw.3. Battery replacement Replacement Procedure:For calibration and inspection of the instrument, please contact dealer, sole agent and maker.2. Calibration1. Maintenance check 1) External finish2) Light sensorCheck if the external finish is damaged by dropping the instrument, etc.Check if the light sensor surface is damaged or durty.Check if the light sensor cord is damaged.If any of the above parts is damaged, do not use the instrument but have it repaired.•••1234••••Light sensor element Measurable wavelength rangeDirectly-readable wavelength DisplayOver load indication Low battery indication Sampling rate RangesMeasured object Accuracy FunctionsEMC directive, RoHS directive Power supplyPower consumption Environmental condition Operating temperature /humidity range Storage temperature /humidity range DimensionsLight sensor probe Sensor cord length AccessoriesSi photodiode (Light sensor surface diameter Ø 9 mm)with diffusion sheet 400 nm to 1100 nm633 nm (He-Ne laser)Other wavelengths should be converted using typical correction factorDigital display: 4039 full scaleBar graph display: 41-segment display displays“OL”Blinking “BT” appears in the display when the built-in batteries are nearly exhausted and battery supply voltage drops Digital display: Approx. 3 times/sec.Bar graph display: Approx. 30 times/sec.40 μW range: 0.01 μW to 40.39 μW 400 μW range: 0.1 μW to 403.9 μW 4 mW range: 0.001 mW to 4.039 mW 40 mW range: 0.01 mW to 40.39 mWCW laser, the modulated laser cannot be measured accurately ±5 % (in the 4 mW range, at the reference wavelength of 633 nm and 1 mW)Temperature: 23 ±2MIN Hold function, MAX Hold functionAuto power save function (15 min. after operation)IEC61326(EMC). EN50581(RoHS).LR44 1.5 V x 2Approx. 8 mWAltitude 2000 m or below, pollution degree Ⅱ.Temperature 0 to 40 , humidity 80 %RH or less (without condensation)Temperature -10 to +50 , humidity 80 %RH or less (without condensation)117(H ) x 76(W ) x 18(D ) mm, approx. 120 grams 84(H ) x 16(W ) x 10(D ) mm Approx. 0.5 m when extended Instruction manual x 1[9] SpecificationsDesign and specifications are subject to change for reasons of improvement, etc.INSTRUCTION MANUALLASER POWER METERDempa Bldg., 4-4 Sotokanda 2-ChomeChiyoda-ku, Tokyo, JapanLP10Light sensor probe -3--2--6--4--5--1--7--8-。
Rubson Aero 360 潮湿调节剂数据安全卡说明书
Ficha de Datos de Seguridad según el Reglamento (CE) n° 1907/2006página 1 de 9Rubson Aero 360Nº FDS : 505142V002.2Revisión: 21.12.2016Fecha de impresión: 17.07.2017Reemplaza la versión del: 01.12.20161.1. Identificador del productoRubson Aero 3601.2. Usos pertinentes identificados de la sustancia o de la mezcla y usos desaconsejadosUso previsto:Deshumidificador1.3. Datos del proveedor de la ficha de datos de seguridadHENKEL IBERICA S.A. Bilbao 72-84 08005 BarcelonaEspañaTeléfono: +34 (93) 290 4201 Fax:+34 (93) 290 4181*****************************.com1.4. Teléfono de emergenciaAsistencia en español: Henkel Ibérica, S.A: (+34)93 290 4100 (Centralita, 24h) ó (+34)704 10 00 87 (Emergencias de transporte)Instituto Nacional de Toxicología: Tel (emergency): +34.91.562.04.202.1. Clasificación de la sustancia o de la mezclaClasificación (CLP):Corrosivo para los metalesCategoría 1 H290 Puede ser corrosivo para los metales. Irritación ocularCategoría 2H319 Provoca irritación ocular grave.2.2. Elementos de la etiqueta Elementos de la etiqueta (CLP):Pictograma de peligro:Palabra de advertencia:AtenciónIndicación de peligro: H290Puede ser corrosivo para los metales.H319Provoca irritación ocular grave.Consejo de prudencia: P101Si se necesita consejo médico, tener a mano el envase o la etiqueta.P102Mantener fuera del alcance de los niños.P280Úsese protección para los ojos/la cara.P305+P351+P338EN CASO DE CONTACTO CON LOS OJOS:Aclarar cuidadosamentecon agua durante varios minutos. Quitar las lentes de contacto, si lleva y resulta fácil.Seguir aclarando.P337+P313Si persiste la irritación ocular: Consultar a un médico.2.3. Otros peligrosNinguno si se usa según lo dispuesto.No cumple con los criterios de Persistente, Bioacumulativo y Tóxico (PBT), ni con los de muy Persistente y muy Bioacumulativo (vPvB.3.2. MezclasDescripción química general:Agente deshumificadorSustancias base de la preparación:Chloruro de CalcioDeclaración de componentes conforme al Reglamento CLP (CE) No. 1272/2008:Ver el texto completo de las frases H y otras abreviaturas en la sección 16 "Otros datos".Para sustancias sin clasificación pueden existir límites de exposición en los lugares de trabajo.4.1. Descripción de los primeros auxiliosInformación general:En caso de malestar acudir a un médico.Inhalación:Aire fresco, si persisten los síntomas consultar al doctor.Contacto de la piel:Lavar con agua corriente y jabon. Cuidar la piel. Separar las ropas contaminadas.Contacto con los ojos:Lavar los ojos inmediatamente con agua o con una solución de limpieza para los ojos durante 5 minutos como mínimo. Si el dolor no desaparece (escozor intenso, sensibilidad a la luz, alteración de la capacidad visual), continuar limpiando y ponerse en contacto o acudir a un médico u hospital.Ingestión:Lavado de la cavidad bucal. Beber 1-2 vasos de agua, consultar con un médico.4.2. Principales síntomas y efectos, agudos y retardadosOJOS: Irritación, conjuntivitis.4.3. Indicación de toda atención médica y de los tratamientos especiales que deban dispensarse inmediatamente Véase la sección: Descripción de los primeros auxilios5.1. Medios de extinciónExtintor apropiado:anhídrido carbónico, espuma, polvo seco, sistema de agua pulverizada, sistema de agua atomizadaLos medios de extinción que no deben utilizarse por razones de seguridad:Chorro de agua a alta presión5.2. Peligros específicos derivados de la sustancia o la mezclaEn caso de incendio puede formarse cloro gas.5.3. Recomendaciones para el personal de lucha contra incendiosLlevar puesta protección respiratoria independiente del aire ambiente.Llevar el equipo de protección personal.6.1. Precauciones personales, equipo de protección y procedimientos de emergenciaEvitar el contacto con los ojos y la piel.Evitar la formación de polvo.Utilícese indumentaria de protección personal.6.2. Precauciones relativas al medio ambienteNo es necesario.6.3. Métodos y material de contención y de limpiezaAbsorción mecánicaEliminar el material contaminado como residuo, de acuerdo con la sección 13.6.4. Referencia a otras seccionesVer advertencia en la sección 8.7.1. Precauciones para una manipulación seguraAbrir y manipular el envase con cuidado.Evítese el contacto con los ojos y la piel.Medidas de higiene:No comer, beber ni fumar durante el trabajo.Lavarse las manos antes de las pausas y al finalizar el trabajo.7.2. Condiciones de almacenamiento seguro, incluidas posibles incompatibilidadesAlmacenar en lugar seco y fresco.Evitar estrictamente temperaturas por debajo de 0 °C y por encima de + 50 °C.No guardar junto a productos alimenticios7.3. Usos específicos finalesDeshumidificador8.1. Parámetros de controlLímites de Exposición OcupacionalVálido paraEspañaningunoDerived No-Effect Level (DNEL):Índice de exposición biológica:ninguno8.2. Controles de la exposición:Protección respiratoria:No es necesario.Protección manual:En el caso de un contacto prolongado se recomiendan guantes protectores de caucho nitrilo según la norma EN 374.tiempo de penetración > 480 minespesor del material > 0,1 mmEn el caso de contacto prolongado o repetido hay que tener en cuenta que los tiempos de penetración pueden ser en la práctica mucho más cortos que los determinados según EN 374. Se debe comprobar siempre que los guantes de protección son los adecuados para cada trabajo específico (por ejem. resistencia mecánica, témica, compatibilidad con el producto, efectos antiestáticos, etc.). Los guantes de protección deben ser sustituidos inmediatamente cuando aparecen los primeros signos de desgaste. Se tiene que tener siempre en cuenta tanto la información facilitada por el fabricante como la proveniente de la mutua de accidentes. Recomendamos trazar un plan de protección para las manos en colaboración con los fabricantes de guantes y las mutuas de accidentes.Protección ocular:Usar gafas de proteccion ajustadas.El equipo de protección ocular debería ser conforme a EN 166Protección corporal:Ropa de protección adecuadaLa ropa de protección debería ser conforme a EN 14605 para salpicaduras de líquidos o a la norma EN 13982, para polvo. Instrucciones sobre el equipo de protección personal:La información suministrada sobre equipos de protección individual se ofrece sólo como guía. Debe realizarse una valoración de riesgos total antes de utilizar este producto, con el fin de determinar cuáles son los equipos de protección más adecuados a las condiciones de trabajo. Los equipos de protección individual deben cumplir con la norma EN aplicable.9.1. Información sobre propiedades físicas y químicas básicasAspecto PastillassolidoAzul, BlancoOlor típicoUmbral olfativo No hay datos / No aplicablepH No hay datos / No aplicablePunto inicial de ebullición No disponiblePunto de inflamación No hay datos / No aplicableTemperatura de descomposición No hay datos / No aplicablePresión de vapor No hay datos / No aplicableDensidad No hay datos / No aplicableDensidad aparente No hay datos / No aplicableViscosidad No hay datos / No aplicableViscosidad (cinemática) No hay datos / No aplicablePropiedades explosivas No hay datos / No aplicableSolubleSolubilidad cualitativa(23 °C (73.4 °F); Disolvente: Agua)Temperatura de solidificación No hay datos / No aplicablePunto de fusión No disponibleInflamabilidad No hay datos / No aplicableTemperatura de auto-inflamación No hay datos / No aplicableLímites de explosividad No hay datos / No aplicableCoeficiente de reparto n-octanol/agua No hay datos / No aplicableTasa de evaporación No hay datos / No aplicableDensidad de vapor No hay datos / No aplicablePropiedades comburentes No hay datos / No aplicable9.2. Otros datosNo hay datos / No aplicable10.1. ReactividadA temperaturas superiores a 770ºC, se produce descomposición y desprendimiento de cloro.10.2. Estabilidad químicaEstable bajo las condiciones de almacenamiento recomendadas.10.3. Posibilidad de reacciones peligrosasVer sección reactividad10.4. Condiciones que deben evitarseNinguno conocido si se usa según lo dispuesto.10.5. Materiales incompatiblesVer sección reactividad.10.6. Productos de descomposición peligrososNinguno conocido11.1. Información sobre los efectos toxicológicosInformaciones generales toxicológicos:La mezcla está clasificada en base a la información de peligro disponible para los ingredientes tal y como se define en el criterio de clasificación para mezclas de cada clase de peligro o diferenciación en el Anexo I del Reglamento (CE) N° 1272/2008. Información de sanidad y ecológica relevante disponible para las sustancias listadas en la Sección 3 se proporciona a continuación.Irritación de los ojos:Provoca irritación ocular grave.Toxicidad oral aguda:Toxicidad inhalativa aguda:Toxicidad dermal aguda:Corrosión o irritación cutáneas:Lesiones o irritación ocular graves:Mutagenicidad en células germinales:Detalles generales de ecología:La mezcla está clasificada en base a la información de peligro disponible para los ingredientes tal y como se define en el criterio de clasificación para mezclas de cada clase de peligro o diferenciación en el Anexo I del Reglamento (CE) N° 1272/2008. Información de sanidad y ecológica relevante disponible para las sustancias listadas en la Sección 3 se proporciona a continuación.Ninguna12.1. Toxicidad12.2. Persistencia y degradabilidadNo hay datos.12.3. Potencial de bioacumulación / 12.4. Movilidad en el suelo No hay datos.12.5. Resultados de la valoración PBT y mPmB12.6. Otros efectos adversosNo hay datos.13.1. Métodos para el tratamiento de residuosEvacuación del producto:Eliminar residuos de acuerdo con la legislación localEvacuación del envase sucio:Reciclar los envases solo cuando estén completamente vacíos.Código de residuo06031414.1.Número ONUNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.2.Designación oficial de transporte de las Naciones UnidasNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.3.Clase(s) de peligro para el transporteNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.4.Grupo de embalajeNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.5.Peligros para el medio ambienteNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.6.Precauciones particulares para los usuariosNo es un producto peligroso según RID, ADR, ADN, IMDG, IATA-DGR14.7.Transporte a granel con arreglo al anexo II del Convenio MARPOL y el Código IBCno aplicable15.1. Reglamentación y legislación en materia de seguridad, salud y medio ambiente específicas para la sustancia o la mezclaTenor VOC0 %(VOCV 814.018 VOC regulationCH)15.2. Evaluación de la seguridad químicaSe ha realizado una evaluación de seguridad química.El etiquetado del producto se indica en la sección 2. El texto completo de todas las abreviaturas indicadas por códigos en esta hoja de seguridad es el siguiente:H290 Puede ser corrosivo para los metales.H319 Provoca irritación ocular grave.Otra información:Ésta información se basa en el estado actual de nuestros conocimientos y se refiere al producto en la forma en que se suministra. Pretende describir nuestros productos bajo el punto de vista de los requisitos de seguridad y no pretende garantizar ninguna propiedad o característica particular.Los cambios relevantes en esta ficha de datos de seguridad están indicados por una línea vertical en la margen izquierda del texto. El texto correspondiente aparece en un color diferente y en campos sombreados.Los escenarios de exposición para el cloruro de calcio pueden descargarse en el siguiente enlace:/mymsds/.563455..en.ANNEX_DE.26270212.0.DE.pdf Adicionalmente, puede accederse a ellos en internet, , bajo el código 563455.。
壳聚糖-肉桂精油复合涂膜的制备及其对核桃贮藏品质的影响
包装工程第44卷第21期·152·PACKAGING ENGINEERING2023年11月壳聚糖-肉桂精油复合涂膜的制备及其对核桃贮藏品质的影响李保祥,马鑫,谢思旎,刘佳怡,王广媛,王俊彦,李统兵(新疆农业大学食品科学与药学学院,乌鲁木齐830052)摘要:目的研究壳聚糖(Chitosan,CS)浓度和肉桂精油(Cinnamon Essential Oil,CEO)添加量对复合膜性能(力学性能、透氧率、吸湿率、抗氧化性)的影响及最佳复合涂膜对核桃贮藏品质的作用效果。
方法采用不同质量分数(1%、1.5%、2%)的CS与不同质量分数(0.1%、0.2%、0.3%、0.4%)的CEO制备复合涂膜,对涂膜的各项性能进行表征,采用最佳比例的复合涂膜处理核桃,测定核桃在贮藏期间的营养及氧化相关指标的变化。
结果质量分数为1.5%的CS和质量分数为0.3%的CEO制备的复合膜具备良好的机械与抗氧化性能,经过涂膜处理后的核桃相较于对照组和纯CS处理组能够有效保持核桃在贮藏期间含水量、可溶性蛋白、脂肪的含量及较高的过氧化物酶(Peroxidase,POD)活性;同时抑制了核桃在贮藏期间酸价、丙二醛含量、多酚氧化酶(Polyphenol Oxidase,PPO)活性的增加。
结论添加CEO能够有效提升壳聚糖涂膜的性能,最佳比例制备的CS-CEO复合涂膜可以较好地保持核桃在贮藏期间的营养与抗氧化品质。
关键词:壳聚糖(CS);肉桂精油(CEO);性能表征;核桃;贮藏品质中图分类号:TS255.3 文献标识码:A 文章编号:1001-3563(2023)21-0152-09DOI:10.19554/ki.1001-3563.2023.21.019Preparation of Chitosan Cinnamon Essential Oil Composite Film and Its Effect onWalnut Storage QualityLI Bao-xiang, MA Xin, XIE Si-ni, LIU Jia-yi, WANG Guang-yuan, WANG Jun-yan, LI Tong-bing (College of Food Science and Pharmacy, Xinjiang Agricultural University, Urumqi 830052, China)ABSTRACT: The work aims to investigate the effect of chitosan (CS) concentration and cinnamon essential oil (CEO) addition on the properties of composite films (mechanical properties, oxygen permeability, moisture absorption, resistance to oxidation) and the optimal effect of composite films on the storage quality of walnuts. This study adopted CS with different mass concentrations (1%, 1.5%, 2%) and CEO with different mass concentrations (0.1%, 0.2%, 0.3%, 0.4%) to prepare composite films. Various properties of the films were characterized. Walnuts were treated with the optimal ratio of composite films to determine the changes in nutritional and oxidative related indicators during storage. The results showed that the composite film prepared with 1.5% concentration of CS and 0.3% concentration of CEO had good mechanical properties and resistance to oxidation. Compared with the control and pure CS treatment, the walnut treated with the film could effectively maintain its water content, soluble protein, fat content, and high peroxidase (POD) activity during storage; At the same time, it inhibited the increase in acid value, malondialdehyde content, and polyphenol oxidase (PPO) activity of walnuts during storage. Therefore, adding CEO can effectively improve the properties of chitosan films,收稿日期:2023-04-18基金项目:2022年中央财政林草科技推广示范项目([2022]TG11);新疆农业大学校级大学生创新创业项目(dxscx2022344)第44卷第21期李保祥,等:壳聚糖-肉桂精油复合涂膜的制备及其对核桃贮藏品质的影响·153·and the CS-CEO composite film prepared in the optimal proportion can better maintain the nutritional and antioxidant quality of walnuts during storage.KEY WORDS: chitosan (CS); cinnamon essential oil (CEO); property characterization; walnut; storage quality新疆是我国最早种植核桃(Juglans regia L.)的地区,栽培历史悠久。
海尔热水器用户手册说明书
SENS-IN-7B 18-HD60D35-2LibraryService LiteratureProduct Section UnitaryProduct Unitary AccessoryModel T'Stats, Panels, Timers, RelaysLiterature Type Installation InstructionsSequence 7BDate January 2001File No.SV-UN-ACC-SENS-IN-7B 1/01SupersedesSENS-IN-7AZone Sensor Modulefor Heat Pump Units Dual Setpoint, Auto C/OBAYSENS09B ASYSTAT664BDescriptionThis Zone Sensor Module provides the following features and system control functions:- System control switch to select heating mode (HEAT), cooling mode (COOL) automatic selection of heating or cooling as re-quired (AUTO), Emergency Heat only (EM. HEAT), or to turn the system off (OFF).- Fan control switch to select automatic fan operation while ac-tively heating or cooling (AUTO), or continious fan operation (ON). - Dual Temperature setpoint levers for setting desired tempera-ture. The blue lever controls cooling, and the red lever controls heating.- Thermometer to indicate temperature in the zone. (This indicator has been factory calibrated.)Application- Used with Heat Pump packaged units (2 - 20 ton).Installer's GuideCustomer Property: Contains wiring and service informa-tion. Please retain.Models :Since the manufacturer has a policy of continuous product improvement,it reserves the right to change design and specifications without notice.InspectionCheck packaging and contents for damage. Check for concealed damage before storing. Report any damage immediately to the transportation company, and make any appropriate claims. Installation Steps1.Mounting location. Choose a spot on an interior wallnear the return air grille, about five feet above floor level,where air circulates freely and is of average tempera-ture for the zone.Avoid areas such as:- behind doors;- on outside walls, or any walls with unheated oruncooled areas behind the zone sensor;- in direct sunlight, or any source of radiant heat thatcould affect the temperature measurements; or- in line with the discharge air from the unit beingcontrolled.2. Mount subbase. Remove zone sensor cover from the sub-base, and mount subbase on the wall or in a 2 x 4 handy box.Route the wires through the wire access hole in the subbase.(See Figure 1) Seal the hole in the wall behind the subbase. Figure 1 - Zone Sensor Mounting (typical)Wiring!H A Z A R D O U S V O LTA G E!DISCONNECT ALL ELECTRIC POWER INCLUDING RE-MOTE DISCONNECTS BEFORE SERVICING.Failure to disconnect power before servicing can cause severe personal injury or death.Note: Guidelines for wire sizes and lengths are shown in Table 1.The total resistance of these low voltage wiresmust not exceed 2.5 ohms per conductor. Any resis-tance greater than 2.5 ohms may cause the control tomalfunction due to excessive voltage drop.Note: Do Not run low-voltage control wiring in sameconduit with high-voltage power wiring.1.Run wires. Run wires between the unit control paneland the zone sensor subbase. To determine the numberof wires required, refer to Unit IOM for Wiring Connections.2. Connect wires. Connect the wiring to the appropriateterminals at the unit control panel and at the ZoneSensor subbase. In general, zone sensor connections to the unit use the convention of connecting Zone Sensor terminals to like numbered Unit terminals (1 to 1, 2 to 2, etc.). The connec-tion detail is shown on the unit wiring diagrams which can be found in the unit service literature and on the unit.3. Replace cover. Place zone sensor cover back on thesubbase, snap securely into place.Table 1151 - 240 feet20 gauge241 - 385 feet18 gauge386 - 610 feet16 gauge611 - 970 feet14 gaugeOptional Remote Sensor (BAYSENS017)When using the optional remote sensor (BAYSENS017), mount it in the space that is to be controlled. Clip the thermistor (RT1) on the zone sensor module. Wire remote sensor to the zone sensor module according to the interconnecting wiring dia-grams in the unit's IOM.© American Standard Inc. 2001Technical Literature Printed in USA2。
吉满生物科技(上海)有限公司产品说明书
产品手册H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line H_HLA-G1 PDL1 MC38(mouse_PDL1 KO)细胞系For research use only!本品仅供科研使用,严禁用于治疗!版本号:V2.8目录一、产品基本信息及组分 (3)二、包装、运输及储存 (3)三、材料准备 (3)1.细胞培养、冻存、复苏试剂准备 (3)2.试剂耗材准备 (3)四、细胞培养、复苏、冻存 (4)1.H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line细胞复苏 (4)2.H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line细胞传代 (4)3.H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line细胞冻存 (4)五、验证结果 (5)1.流式检测蛋白表达-HLA-G1 (5)2.流式检测蛋白表达-PDL1 (6)使用许可协议: (7)附录1 Mouse_PDL1敲除验证结果 (8)附录2 H_HLA-G1氨基酸序列(NP_002118.1) (9)附录3 H_PDL1氨基酸序列(NP_054862.1) (10)一、产品基本信息及组分基本信息产品编号产品名称规格GM-C22142H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line 1 kit产品组成产品编号产品名称规格数量储存GM-C24483H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line #45E6 Cells/mL1管-196℃GM-C24484H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line #55E6 Cells/mL1管-196℃Pen/Strep100 mL Thermo/15140-122Fetal Bovine Serum500 mL Thermo/10099141DMEM 500 mL gibco/C11995500BT/8122062Anti-H_CD274(PDL1) hIgG1 Antibody / Genomeditech/GM-31740ABAnti-H_HLA-G1 hIgG1 Antibody / Genomeditech/GM-28208AB细胞计数仪ThermoFisher Scientific/Countess 3流式细胞仪贝克曼库尔特国际贸易(上海)有限公司/CytoFLEX四、细胞培养、复苏、冻存1.H_HLA-G1 PDL1 MC38(mouse_PDL1 KO) Cell Line细胞复苏a)37℃水浴锅预热培养基,加入预热后的完全培养基5 mL至15 mL离心管。
NEB 2015年目录价
R3122V ScaI-HF500 units R3131L NheI-HF5,000 units R3131M NheI-HF, high5,000 units R3131S NheI-HF1,000 units R3131V NheI-HF500 units R3132L SspI-HF5,000 units R3132M SspI-HF, high5,000 units R3132S SspI-HF1,000 units R3132V SspI-HF500 units R3133L SpeI-HF2,500 units R3133M SpeI-HF, high2,500 units R3133S SpeI-HF500 units R3133V SpeI-HF250 units R3136L BamHI-HF50,000 units R3136M BamHI-HF, high conc.50,000 units R3136S BamHI-HF10,000 units R3136T BamHI-HF, high conc.10,000 units R3136V BamHI-HF5,000 units R3138L SalI-HF10,000 units R3138M SalI-HF, high conc.10,000 units R3138S SalI-HF2,000 units R3138T SalI-HF, high conc.2,000 units R3138V SalI-HF1,000 units R3140L PstI-HF50,000 units R3140M PstI-HF, high conc.50,000 units R3140S PstI-HF10,000 units R3140T PstI-HF, high conc.10,000 units R3140V PstI-HF5,000 units R3142L KpnI-HF20,000 units R3142M KpnI-HF, high conc.20,000 units R3142S KpnI-HF4,000 units R3142V KpnI-HF2,000 units R3150L PvuI-HF2,500 units R3150S PvuI-HF500 units R3150V PvuI-HF250 units R3151L PvuII-HF25,000 units R3151M PvuII-HF, high conc.25,000 units R3151S PvuII-HF5,000 units R3151V PvuII-HF2,500 units R3156L SacI-HF10,000 unitsR3156V SacI-HF1,000 units R3162L BstEII-HF10,000 units R3162M BstEII-HF, high conc.10,000 units R3162S BstEII-HF2,000 units R3182L SphI-HF2,500 units R3182M SphI-HF, high conc.2,500 units R3182S SphI-HF500 units R3182V SphI-HF250 units R3189L NotI-HF2,500 units R3189M NotI-HF, high conc.2,500 units R3189S NotI-HF500 units R3189V NotI-HF250 units R3193L NcoI-HF5,000 units R3193M NcoI-HF, high conc.5,000 units R3193S NcoI-HF1,000 units R3193V NcoI-HF500 units R3195L EcoRV-HF20,000 units R3195M EcoRV-HF, high conc.20,000 units R3195S EcoRV-HF4,000 units R3195T EcoRV-HF, high conc.4,000 units R3195V EcoRV-HF2,000 units R3500L StyI-HF15,000 units R3500S StyI-HF3,000 units R3505L EagI-HF2,500 units R3505M EagI-HF, high conc.2,500 units R3505S EagI-HF500 units R3510L DraIII-HF5,000 units R3510S DraIII-HF1,000 units R3535L BsaI-HF5,000 units R3535S BsaI-HF1,000 units R3552L AgeI-HF1,500 units R3552S AgeI-HF300 units R3589L MfeI-HF2,500 units R3589S MfeI-HF500 units R3589V MfeI-HF250 units R3642L SbfI-HF2,500 units R3642S SbfI-HF500 units R3658L BmtI-HF1,500 units R3658S BmtI-HF300 units R5101S EcoRI-HF RE-Mix500 rxnsR5131S NheI-HF RE-Mix50 rxns R5133S SpeI RE-Mix50 rxns R5138S SalI-HF RE-Mix100 rxns R5142S KpnI-HF RE-Mix200 rxns R5145S XbaI RE-Mix150 rxns R5146S XhoI RE-Mix200 rxns R5162S BstEII-HF RE-Mix100 rxns R5189S NotI-HF RE-Mix25 rxns R5193S NcoI-HF RE-Mix50 rxns R5195S EcoRV-HF RE-Mix200 rxns R5547S PacI RE-Mix25 rxns R5552S AgeI-HF RE-Mix25 rxns R5558S AscI RE-Mix50 rxns R5589S MfeI-HF RE-Mix25 rxns S0101V Random Primer25 rxns S1230S Random Primer 6 1.0 A260 units S1254S Random Primer 9 1.0 A260 units S1315S Universal miRNA Cloning Linker 5 μg (0.83 nmol) S1316S Oligo d(T)18 mRNA Primer 5.0 A260 units S1327S Oligo d(T)23VN 1.0 A260 units S1330S Random Primer Mix100 μl (60 μM) S1402S Ribonucleoside-Vanadyl Comple10.0 ml S1404L m7G(5´)ppp(5´)G RNA Cap Struc 5 μmol S1404S m7G(5´)ppp(5´)G RNA Cap Struc 1 μmol S1405L m7G(5´)ppp(5´)A RNA Cap Struc 5 μmol S1405S m7G(5´)ppp(5´)A RNA Cap Struc 1 μmol S1406L G(5´)ppp(5´)A RNA Cap Structur 5 μmol S1406S G(5´)ppp(5´)A RNA Cap Structur 1 μmol S1407L G(5´)ppp(5´)G RNA Cap Structur 5 μmol S1407S G(5´)ppp(5´)G RNA Cap Structur 1 μmol S1408S Oligo (dT)25-Cellulose250 mgS1411L 3´-O-Me-m7G(5´)ppp(5´)GRNA Cap Structure Analog5 μmolS1411S 3´-O-Me-m7G(5´)ppp(5´)GRNA Cap Structure Analog1 μmolS1419S Oligo d(T)25 Magnetic Beads25 mg S1420S Streptavidin Magnetic Beads 5.0 ml S1421S Hydrophilic Streptavidin Magne 5.0 ml S1425S Protein A Magnetic Beads 1.0 ml S1430S Protein G Magnetic Beads 1.0 ml S1431S Goat Anti-Mouse IgG Magnetic 20 mgS1433S Goat Anti-Rat IgG Magnetic Bea20 mg S1506S6-Tube Magnetic Separation Rac 6 tubes (1.5 ml) S1507S50 ml Magnetic Separation Rack 4 tubes (50.0 ml) S1509S12-Tube Magnetic Separation Ra12 tubes (1.5 ml) S1510S2-Tube Magnetic Separation Rac 2 tubes (1.5 ml) S1511S96-Well Microtiter Plate Magnet96-well S1550S Magnetic mRNA Isolation Kit25 isolations S1560S polyA Spin mRNA Isolation Kit8 isolations S6651L Chitin Resin100.0 ml S6651S Chitin Resin20.0 ml S6651V Chitin Resin10.0 ml S9101S SNAP-Cell 36050 nmol S9103S SNAP-Cell 505-Star50 nmol S9104S SNAP-Cell Oregon Green50 nmol S9105S SNAP-Cell TMR-Star30 nmol S9106S SNAP-Cell Block100 nmol S9107S SNAP-Cell Fluorescein50 nmol S9109S SNAP-Cell 43050 nmol S9110S SNAP-Biotin50 nmol S9112S SNAP-Surface 54950 nmol S9124S SNAP-Surface 48850 nmol S9129S SNAP-Surface Alexa Fluor 48850 nmol S9132S SNAP-Surface Alexa Fluor 54650 nmol S9134S SNAP-Surface 59450 nmol S9136S SNAP-Surface Alexa Fluor 64750 nmol S9137S SNAP-Surface 64750 nmol S9139S SNAP-Surface 68250 nmol S9143S SNAP-Surface Block200 nmol S9144S SNAP-Capture Pull-Down Resin 2.0 ml S9145S SNAP-Capture Magnetic Beads 2.0 ml S9147S SNAP-Vista Green50 nmol S9148S BG-NH2 2 mg S9150S BG-PEG-NH2 2 mg S9151S BG-GLA-NHS 2 mg S9153S BG-Maleimide 2 mg S9217S CLIP-Cell 50550 nmol S9219S CLIP-Cell TMR-Star30 nmol S9220S CLIP-Cell Block100 nmol S9221S CLIP-Biotin50 nmol S9222S BC-PEG-NH2 2 mg S9232S CLIP-Surface 48850 nmol S9233S CLIP-Surface 54750 nmolS9234S CLIP-Surface 64750 nmol S9236S BC-NH2 2 mg S9237S BC-GLA-NHS 2 mg S9348S CoA 48850 nmol S9349S CoA 54750 nmol S9350S CoA 64750 nmol S9351S CoA-Biotin50 nmol T0100V分子克隆纪念套装T0500V Mini Essential 1 box B0101S NEBuffer EcoRI 6.0 mlB0204S T4 RNA Ligase ReactionBuffer 2.5 mlB0490S EpiMark Hot Start TaqReaction Buffer Pack8.0 mlB0543S NEBuffer DpnII 6.0 ml B7000S NEBuffer Set 1,2,3,4 & BSA4x1.5 ml B8004S Diluent D 4.0 ml B8005S Diluent E 4.0 mlM0326V Crimson LongAmp Taq DNAPolymerase125 unitsM0361L Pyrophosphatase, Inorganic(E. coli)50 unitsN3022L PhiX174 RF II DNA150 µgP5205S Brugia malayi chitinase(BmCHT1)500 unitsP5206S Onchocerca volvuluschitinase (OvCHT1)500 unitsP5208S Plasmodium falciparumchitinase (PfCHT1)100 unitsR0132V SspI500 units M0371L Shrimp Alkaline Phosphatase (rS2,500 units M0371S Shrimp Alkaline Phosphatase (rS500 units M0249L RecA Protein1,000 μgM0249S RecA Protein200 μg R0652L AfeI1,000 units R0652S AfeI200 units B0216L T4 RNA Ligase Reaction Buffer P 3.0 mlS9159S SNAP-Surface® 64950 nmol P8107S Proteinase K, Molecular Biology 2 ml E7580S NEBNext®Multiplex Small RNA 24 rxns E7580L NEBNext®Multiplex Small RNA 96 rxns N0550S Quick-Load Purple 2-Log DNA L250 gel lanes B7024S Gel Loading Dye Purple (6X) 4.0 ml P0708S PNGaseF Recombinant15,000 units P0708L PNGaseF Recombinant75,000 units P0709S PNGaseF Glycerol Free - Recomb15,000 units P0709L PNGaseF Glycerol Free - Recomb75,000 units E1202S NEB PCR Cloning Kit20 rxns M0375S SplintR Ligase 1,250 units M0375L SplintR Ligase 6,250 units E7535S NEBNext® Multiplex Oligos for 24reaction E7535L NEBNext® Multiplex Oligos for 96reaction T0510V NEB Cloning Panel 1 1 pack T0520V NEB Cloning Panel 2 1 pack T0530V NEB Cloning Panel 3 1 pack T0540V NEB Cloning Panel 4 1 pack T0550V NEB Cloning Panel 5 1 pack T0560V NEB Cloning Panel 6 1 pack T0570V NEB Cloning Panel 7 1 pack T0580V NEB Cloning Panel 8 1 pack T0590V NEB Cloning Panel 9 1 pack T0600V NEB Cloning Panel 10 1 pack N0450L Ribonucleotide Solution Set50 μmol of each B0349S NEBNext dsDNA Fragmentase R 6.0 ml E0552S Q5® Site-Directed Mutagenesis S (10 reactions) M0386S Cas9 Nuclease, S. pyogenes50 pmolE7600S NEBNext Multiplex Oligos for Illumina(Dual Index PrimersSet 1)96 rxnsP7712S Color Protein Standard,Broad Range (11-245 kDa)100 gel lanesP7712V Color Protein Standard,Broad Range (11-245 kDa)50 gel lanesP7706S Blue Protein Standard,BroadRange (11-190 kDa)100 gel lanesP7706V Blue Protein Standard,BroadRange (11-190 kDa)50 gel lanesM0386L Cas9 Nuclease, S. pyogenes250 pmolsE5520S NEBuilder® HiFi DNA Assembly Clo10 rxnsM0543S NEBNext®Q5®Hot StartHiFi PCR Master Mix50 reactionsM0543LNEBNext®Q5®Hot StartHiFi PCR Master Mix250 reactionsM6630S NEBNext®FFPE DNA RepairMix24 reactionsM6630LNEBNext®FFPE DNA RepairMix96 reactionsM0386M Cas9 Nuclease, S. pyogenes500 pMol R0680S BssSal200 units R0680L BssSal1,000 units R3198V MluI-HF®500 units R3198S MluI-HF®1,000 units R3198L MluI-HF®5,000 units R3575V BsrGI-HF®500 units R3575S BsrGI-HF®1,000 units R3575L BsrGI-HF®5,000 units R3192V NruI-HF®500 units R3192S NruI-HF®1,000 units R3192L NruI-HF®5,000 units R3127v NsiI-HF®500 units。
BPS4000产品规格说明书
1 2 3 4 5 6 7 8 9Specification StatusChange Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy 160-006AM040322BHTI Alternate Materials List M&P 299-947-100-690115BHTI Procurement Specification for Epoxy Adhesive, Heat Resistant M&P 299-947-320-820507BHTIAdhesive Film and Primer System, Intermedite Cure Temperature (260-290º F) ServiceTemerature 67-225º F)M&P 68A900000G011101BAC Finish Spec:F-15M&P 74A900000E990308BAC Finish Specification for F18 Aircraft M&P 74A900004L010501BAC Ctrl:Fract Crit Parts, F-18M&P 74A901001F981208BAC Std Finish Codes:F-18 A\C M&P 901-947-002CA D950510BHTI Finish Specification for the V-22 Aircraft (Bell Boeing) Model 901) EMD Aircraft M&P10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26A-A-208B951120Notice 2 Notice 3FED Ink, Marking, Stencil, Opaque M&P A-A-2962Cancelled no s/s spec A980810canc notice 2-060106FED Commercial Item Description Enamel, Alkyd, Exterior, Solvent Based, Low Voc ok to use canc spec M&P A-A-3097BK-970506Notice 3FEDCommercial Item Description Adhesives, Cyanoacrylate, Rapid Room Temperature-Curing,SolventlessM&P A-A-3165CA A071116Notice 2FED Lacquer, Gloss, for A/C Use M&P A-A-52080B980523Notice 1FED Tape, Lacing, and Tying, Nylon M&P A-A-52081B980523FED Tape, Lacing, and Tying, Polyester M&P A-A-52082CE C070904Notice 1FED Tape, Lacing and Tying, TFE-Fluorocarbon M&P A-A-52083BJ C040223FED Tape, Lacing, and Tying, Glass M&P A-A-52084B980523Notice 1FED Tape, Lacing and Tying, Aramid M&P A-A-55829-970204Notice 1DLA Acetic Acid, Glacial, Technical M&P A-A-56032CN D030521Notice 1FED Commercial Item Description (CIDS) Ink, Marking, Epoxy Base M&P A-A-59126-970926FED Terminals, Feedthru (Insulated) and Terminals, Stud (Insulated and Noninsulated)ENG A-A-59132CR A100607Validation Notice 1DLA Amyl Acetate, Technical M&P A-A-59135CR-971028FED Commercial Item Description Packaging Material, Sheet M&P A-A-59136CR-971028FED Cushioning Material, Packaging, Closed Cell Foam Plank M&P A-A-59178CL A041012USGOVT Nipple, Electrical Terminal ENG A-A-59503CG B081020FED Commercial Item Description Nitrogen, Technical M&P A A59551Wire Electrical Copper(Uninsulated)27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44A-A-59551CP A091022USGOVT Wire, Electrical, Copper (Uninsulated) M&P A-A-59569CK C090122DLA Qualification Sampling and Testing of Steels for Transverse Tensile Properties ENG A-A-59588BK A050707FED Commercial Item Description Rubber, Silicone M&P A-A-59877CT-100909FED Comemrcial Item Description Insulating Compound, Electrical, Embedding M&P AIR4127CG - 071101SAE Steel: Chemical Composition and Hardenability M&P AISI-1010Unavailable-AISI Low Carb Stl Unavailable M&P AISI-50100Unavailable-AISI Bearing Stl Unavailable M&P AISI-52100Unavailable-AISI Bearing Stl Unavailable M&P AISI-B-1112Unavailable-AISI Low Carb Free Mach Stl Unavailable M&P AISI-C-1212Unavailable-AISI Matl Spec, Stl Unavailable M&P AISI-C-1213Unavailable-AISI Low Carb Free Mach Stl Unavailable M&P AISI-C-1214Unavailable-AISI Matl Spec, Stl Unavailable M&P AMS 2175CR A100601SAE Castings, Classification and Inspection of M&PAMS 2201Cancelled CN Can940901SAETolerances Aluminum and Aluminum Alloy Bar, Rod, Wire, and Forging Stock Rolled or Cold-FinishedANSI H35.2M&PAMS 2221G060201SAE Tolerances, Copper and Copper Alloy Bars and Rods M&P AMS 2222BG J060201SAE Tolerances, Copper and Copper Alloy Sheet, Strip, and Plate M&P AMS 2223BF H060201SAE Tolerances Copper and Copper Alloy Seamless Tubing M&P AMS 2224G060201SAE Tolerances Copper and Copper Alloy Wire M&P AMS2241Tolerances,Corrosion and Heat-Resistant Steel,Iron Alloy,Titanium,and Titanium Alloy Bars and45 46 47 4849 50 51 52 53 54 55 56 57 58AMS 2241CN R070701SAETolerances, Corrosion and Heat Resistant Steel, Iron Alloy, Titanium, and Titanium Alloy Bars andWireM&P AMS 2242CC G080604SAETolerances Corrosion and Heat Resistant Steel, Iron Alloy, Titanium and Titanium Alloy Sheet,Strip and PlateM&P AMS 2243BJ H060501SAE Tolerances Corrosion and Heat-Resistant Steel Tubing M&P AMS 2248CN F060501SAEChemical Check Analysis Limits Corrosion and Heat-Resistant Steels and Alloys, Maraging andother Highly-Alloyed Steels, and Iron AlloysM&PAMS 2249CN G090701SAEChemical Check Analysis Limits Titanium and Titanium AlloysM&PAMS 2259CN E071201SAE Chemical Check Analysis Limits Wrought Low-Alloy and Carbon Steels M&P AMS 2269CN F060501SAE Chemical Check Analysis Limits Nickel, Nickel Alloys, and Cobalt Alloys M&P AMS 2300BF K031001SAE Steel Cleanliness, Premium Aircraft-Quality Magnetic Particle Inspection Procedure M&P AMS 2301CT K100801SAE Steel Cleanliness, Aircraft Quality Magnetic Particle Inspection Procedure M&P AMS 2303CT F100801SAESteel Cleanliness, Aircraft Quality, Martensitic Corrosion Resistant Steels Magnetic ParticleInspection ProcedureM&P AMS 2304CN A060301SAE Steel Cleanliness, Special Aircraft-Quality Magnetic Particle Inspection Procedure M&P AMS 2310BE F060201SAE Qualification Sampling and Testing of Steels for Transverse Tensile Properties M&P AMS 2315CN F080101SAE Determination of Delta Ferrite Content M&PAMS 2350Cancelled no s/s spec CN BA891001SAEStandards and Test Methodsok to use canc spec M&P1Specification Status Change Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy59 60 61 62 63 64AMS 2355CN J090701SAEQuality Assurance Sampling and Testing Aluminum Alloys and Magnesium Alloy WroughtProducts (Except Forging Stock), and Rolled, Forged, or Flash Welding RingsM&P AMS 2360CN D070701SAE Room Temperature Tensile Properties of Castings M&P AMS 2370CN J071101SAEQuality Assurance Sampling and Testing Carbon and Low-Alloy Steel Wrought Products andForging StockM&P AMS 2371CN H071101SAEQuality Assurance Sampling and Testing Corrosion and Heat-Resistant Steels and Alloys WroughtProducts and Forging StockM&P AMS 2372CN E070601SAE Quality Assurance Sampling and Testing Carbon and Low-Alloy Steel Forgings M&P AMS 2375CN D070601SAE Control of Forgings Requiring First Article Approval M&PA l d C t l f P i Q lit Tit i All65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82AMS 2380CN F080601SAE Approval and Control of Premium-Quality Titanium Alloys M&P AMS 2400BV W070701SAE Plating, Cadmium M&P AMS 2401CN H071101SAE Plating, Cadmium Low Hydrogen Content Deposit M&P AMS 2403BM L041001SAE Plating, Nickel General Purpose M&P AMS 2404CH F081201SAE Plating, Electroless Nickel M&P AMS 2405Noncurrent CN C841010SAE Electroless Nickel Plate, Low Phosphorous M&P AMS 2406BV L070501SAE Plating, Chromium Hard Deposit M&P AMS 2408CF J081101SAE Plating, Tin M&P AMS 2410CR K100401SAE Plating, Silver Nickel Strike, High Bake M&P AMS 2411CB G080201SAE Plating, Silver for High Temperature Applications M&P AMS 2412CN J091201SAE Plating, Silver Copper Strike, Low Bake M&P AMS 2416K040301SAE Plating, Nickel-Cadmium Diffused M&P AMS 2417G040701SAE Plating, Zinc-Nickel Alloy M&P AMS 2418G060101SAE Plating, Copper M&P AMS 2419BM C030501SAE Plating, Cadmium-Titanium M&P AMS 2420D021201SAE Plating of Aluminum for Solderability Zinc Immersion Pre-Treatment Process M&PAMS 2423**See special notes CE D020401SAE Plating, Nickel Hard DepositContinue to use AMS-QQ-N-290 for Class2 NickelM&PAMS 2424CR F100401SAE NI Plate, Low Stressed Deposit M&P AMS2426D Coating Cadmium Vacuum Deposition83 84 85 86 87 88 89 90 91 92 93 94AMS 2426BT020901SAE Coating, Cadmium Vacuum Deposition M&P AMS 2429C011101SAE Bronze Plate Masking M&P AMS 2430CN R100101SAE Shot Peening, Automatic M&P AMS 2433C041001SAE Plating, Nickel-Thallium-Boron or Nickel-Boron M&P AMS 2434CN C060501SAE Plating, Tin-Zinc Alloy M&P AMS 2435Noncurrent CN G070601SAE Coating, Tungsten Carbide-Cobalt Coating, Detonation Process M&P AMS 2437BN C710111SAE Coating, Plasma Spray Deposition M&P AMS 2438CL D090701SAE Plating, Chromium Thin, Hard, Dense Deposit M&P AMS 2444BM A001201SAE Coating, Titanium Nitride Physical Vapor Deposition M&P AMS 2451BN B060501SAE Plating, Brush General Requirements M&PAMS 2460See special notes CA-070701SAE Plating, ChromiumIf dwg requires chrome plate per AMS-QQ-C-320 then stress relief and embritlmnt(emb) bake relief per BPS4620. If dwg req'schrome plate per AMS 2460 then stressrelief and bake relief per AMS 2460 unlessthe dwg specifically req's BPS 4620M&PAMS 2468Cancelled CN G981001SAE Hard Anodic Coating Treatment of Aluminum Alloys AMS 2469M&P AMS 2469CG H080701SAEHard Anodic Coating Treatment of Aluminum and Aluminum Alloys Processing and PerformanceRequirementsM&P95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111qAMS 2470CN M070401SAE Anodic Treatment of Aluminum Alloys Chromic Acid Process M&P AMS 2471CN G081201SAE Anodic Treatment of Aluminum Alloys Sulfuric Acid Process, Undyed Coating M&P AMS 2481CP J100201SAE Phosphate Treatment Antichafing M&PAMS 2482CN D100101SAEHard Anodic Coating on Aluminum Alloys Polytetrafluoroethylene (PTFE)-Impregnated orCodepositedM&PAMS 2485BY K080101SAE Coating, Black Oxide M&P AMS 2486CR E100501SAE Conversion Coating of Titanium Alloys Fluoride-Phosphate Type M&P AMS 2487CN A000301SAE Anodic Treatment of Titanium and Titanium Alloys Solution pH 12.4 Maximum M&P AMS 2488D000606SAE Anodic Tr:Ti,Ti Alys M&P AMS 2515BM E900101SAE Polytetrafluoroethylene (PTFE) Resin Coating Low Build, 370 to 400 °C (698 to 752 °F) Fusion M&P AMS 2516BM D900101SAE Polytetrafluoroethylene (PTFE) Resin Coating High Build, 370 to 400 °C (698 to 752 °F) Fusion M&P AMS 2525C030401SAE Graphite Coating, Thin Lubricating Film Impingement Applied M&P AMS 2526BW C071001SAE Molybdenum Disulfide Coating, Thin Lubricating Film Impingement Applied M&P AMS 2615BM F060901SAE Pressure Testing Hydraulic Pressure as Specified M&P AMS 2630CR C100101SAE Inspection, Ultrasonic Product Over 0.5 Inch (12.7 mm) Thick M&P AMS 2631CN C090701SAE Ultrasonic Inspection Titanium and Titanium Alloy Bar and Billet M&P AMS 2632BN A950301SAEInspection, Ultrasonic, Of Thin Materials 0.50 Inch (12.7 mm) and Under in Cross-SectionalThicknessM&P1Specification Status Change Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy112 113 114 115 116 117 118 119 120AMS 2635Cancelled Can810701SAE Radiographic Insp ASTM E1742M&P AMS 2640Cancelled CH Can960401SAE Magnetic Particle Inspection ASTM E1444M&P AMS 2645Cancelled CH Can950201SAE Fluorescent Penetrant Inspection ASTM E1417M&P AMS 2649CA C080101SAE Etch Inspection of High Strength Steel Parts M&P AMS 2658CN C091001SAE Hardness and Conductivity Inspection of Wrought Aluminum Alloy Parts M&P AMS 2664CH F950701SAE Brazing, Silver For Use Up to 800 °F (427 °C)M&P AMS 2665G030101SAE Brazing, Silver for Use up to 400 °F (204 °C)M&P AMS 2666Cancelled Can840101SAE Ag Braz,High Temp AMS 2664M&P AMS 2670BK J060601SAE Brazing, Copper M&P121 122 123 124 125 126 127 128 129 130 131 132 133 134135AMS 2671Cancelled CH Can920101SAE Copper Brazing Corrosion and Heat Resistant Steels and Alloys AMS 2670M&P AMS 2672BM F010301SAE Brazing, Aluminum Torch or Furnace M&P AMS 2673BM D010301SAE Brazing, Aluminum and Aluminum Alloys Molten Flux (Dip)M&P AMS 2675G020501SAE Brazing, Nickel Alloy Filler Metal M&P AMS 2680C010601SAE Electron--Beam Welding for Fatigue Critical Applications M&P AMS 2681B000301SAE Electron Beam Welding M&P AMS 2685Noncurrent CP E071001SAE Welding, Tungsten Arc, Inert Gas GTAW Method M&P AMS 2689Noncurrent CH A980201SAE Fusion Welding Titanium and Titanium Alloys M&P AMS 2694BR B070201SAE In-Process Welding of Castings M&PAMS 2700CF C081101SAE Passivation of Corrosion Resistant SteelsIf no Method & Type are specified must useMethod 1, Type 2,6,7 or 8 depending on thebase material. All acceptance testing shallbe per Class 4.M&PAMS 2728BM A050301SAE Heat Treatment of Wrought Copper Beryllium Alloy Parts M&P AMS 2745CJ A071201SAE Induction Hardening of Steel Parts M&P AMS 2750BN D050901SAE M&P AMS 2753CF C080801SAE Liquid Salt Bath Ferritic Nitrocarburizing Non-Cyanide Bath M&P AMS 2755Cancelled CM Can090701SAE Nitriding, Molten Salt BathProcess not available, consider AMS 2753as replacementM&P136137 138 139140 141 142 143 144 145as replacement.AMS 2759CE E081001SAE Heat Treatment of Steel Parts General Requirements M&P AMS 2759/1CJ E090201SAEHeat Treatment of Carbon & Low-Alloy Steel Parts Minimum Tensile Strength Below 220 ksi (1517Mpa)Supersedes MIL-H-6875 for carbon & low-alloy steels below 220 KSIM&P AMS 2759/10CN A060601SAE Automated Gaseous Nitriding Controlled by Nitriding Potential M&P AMS 2759/11BW-050401SAE Stress Relief of Steel Parts M&P AMS 2759/2CR F100501SAE Heat Treatment of Low-Alloy Steel Parts Minimum Tensile Strength 220 ksi (1517 Mpa) and HigherSupersedes MIL-H-6875 for low-alloysteels, 220 KSI & higher M&P AMS 2759/3CE E080801SAE Heat Treatment Precipitation-Hardening Corrosion-Resistant & Maraging Steel PartsSupersedes MIL-H-6875 for precipitationhardening & maraging steelM&P AMS 2759/4CA C080301SAE Heat Treatment Austenitic Corrosion-Resistant Steel PartsSupersedes MIL-H-6875 for austenticsteelsM&P AMS 2759/5D040601SAE Heat Treatment Martensitic Corrosion Resistant Steel PartsSupersedes MIL-H-6875 for martensiticsteelsM&P AMS 2759/6BM B051101SAE Gas Nitriding & Heat Treatment of Low - Alloy Steel Parts Use Standard Drawing Notes per BDS2240M&P AMS 2759/7CT B100501SAE Carburizing and Heat Treatment of Carburizing Grade Steel Parts M&P1. Infrared pyrometry may be used to146 147 148 149 150 151 152 153 154 155 156AMS 2759/8CG A070601See Special Notes SAE Ion Nitridingmeasure temperature. 2. The nitridingtemperature may be less than 50 degreesbelow the tempering or aging temperatureprovided that the core hardness is notreduced. 3. For small loads, a minimum oftwo acceptance testing specimens may beused in lieu of four, provided that at leastone specimen is placed in each layer.M&P AMS 2759/9CL D090501SAE Hydrogen Embrittlement Relief (Baking of Steel Parts)Supersedes MIL-H-6875 for stress relievingsteelsM&P AMS 2762Noncurrent CP B020101SAE Carburizing Carbon and Low-Alloy Steel Parts M&P AMS 2768CR C100701SAE Heat Treatment of Magnesium Alloy Castings M&P AMS 2770BJ H060801SAE Heat Treatment of Wrought Aluminum Alloy Parts M&P AMS 2771C040701SAE Heat Treatment of Aluminum Alloy Castings M&P AMS 2772BY E080201SAE Heat Treatment of Aluminum Alloy Raw Materials M&P AMS 2774CG B080801SAE Heat Treatment Wrought Nickel Alloy and Cobalt Alloy Parts M&P AMS 2800CN D060801SAE Identification Finished Parts M&P AMS 2801B030301SAE Heat Treatment of Titanium Alloy Parts M&P AMS 2807CF B080201SAEIdentification Carbon and Low-Alloy Steels, Corrosion and Heat-Resistant Steels and Alloys Sheet,Strip, Plate and Aircraft TubingM&P1Specification Status Change Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy157 158 159 160161162AMS 3025CN C090901SAE Polyalkylene Glycol Heat Treat Quenchant M&P AMS 3106Cancelled Can830401SAE Primer, Adhesive,Corr Inhib AMS 3107M&P AMS 3107A910401SAE Primer, Adhesive,Corr-Inhibiting M&P AMS 3195E920101SAE Silicone Rubber Sponge M&PAMS 3216G050901SAE Fluorocarbon (FKM) Rubber High-Temperature - Fluid Resistant Low Compression Set 70 to 80M&P AMS 3218C050901SAE Fluorocarbon (FKM) Rubber High-Temperature - Fluid Resistant Low Compression Set 85 to 95M&P AMS3276Sealing Compound,Integral Fuel Tanks and General Purpose,Intermittent Use to360°F(182°C)163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180AMS 3276CB E080301SAE Sealing Compound, Integral Fuel Tanks and General Purpose, Intermittent Use to 360 F (182 C)M&PAMS 3301G900401SAE Silicone Rubber, Gen Purp,35-45M&P AMS 3305H900401SAE Silicone Rubber, Gen Purp,75-85M&P AMS 3374C050701SAE Sealing Compound Aircraft Firewall M&P AMS 3410J981001SAE Flux,Ag Braz M&P AMS 3411D981001SAE Flux Silver Brz, High Temp M&P AMS 3644BL G060901SAE Plastic: Polyimide For Molded Rod, Bar, and Tube, Plaque, and Formed Parts M&P AMS 3645CN C010101SAE Polychlorotrifluoroethylene (PCTFE), Compression Molded Heavy Sections, Unplasticized M&P AMS 3650CN C910101SAE Rods, Sheets, and Molded Shapes, Polychlorotrifluoroethylene (PCTFE) Unplasticized M&P AMS 3651Cancelled Can870401SAE Ptfe AMS 3667M&P AMS 3651Cancelled Can870401Ptfe AMS 3652M&P AMS 3651Cancelled Can870401Ptfe AMS 3656M&P AMS 3651Cancelled Can870401Ptfe AMS 3660M&P AMS 3652C930101SAE Ptfe Film,Non-Crit Grade M&P AMS 3656CT G080301SAE Ptfe Extrusions,Norm Strength, As Sintered M&P AMS 3657CC D080301SAE Ptfe, Extrusions, Premium M&P AMS 3658CC D080301SAE Ptfe, Extrusions, Premium M&PAMS 3659CR E100501SAE Polytetrafluoroethylene (PTFE) Extrusions, Premium Strength, Sintered and Stress-Relieved M&P AMS3660D100601Polytetrafluoroethylene Moldings M&P181 182 183 184 185 186 187 188 189190191192193194AMS 3660CR SAE Polytetrafluoroethylene MoldingsAMS 3666D930701SAE Ptfe Sht, Glass Reinforced M&P AMS 3667CA D080301SAE Polytetrafluorethylene Sheet, Molded General Purpose Grade, As Sintered M&P AMS 3668CT D100501SAE Ptfe, Moldings, Premium Grade, A Sintered M&P AMS 3670/1B950401SAE Unfilled Polyamide-Imide, Bar M&P AMS 3824CN C950901SAE Cloth, Glass Finished for Resin Laminates M&P AMS 4001Cancelled CK Can070701SAE Aluminum Sheet and Plate 0.12Cu (1100-0) Annealed ASTM B209M&P AMS 4013CN F070501SAE Aluminum Sheet, Laminated Surface Bonded M&P AMS 4015CN L070201SAE Aluminum Alloy, Sheet and Plate 2.5Mg - 0.25Cr (5052-0) Annealed M&PAMS 4016CN L060901SAEAluminum Alloy, Sheet and Plate 2.5Mg - 0.25Cr (5052-H32) Strain Hardened, Quarter Hard, andStabilizedM&P AMS 4017CN K041201SAEAluminum Alloy Sheet and Plate 2.5Mg - 0.25Cr (5052-H34) Strain-Hardened, Half Hard, andStabilizedM&P AMS 4023CN E840401SAEAluminum Alloy Sheet and Plate Alcalad 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr (Alclad 6061; -T6 Sheet,-T651 Plate)M&P AMS 4025CE L080701SAE Aluminum Alloy, Sheet and Plate 1.0Mg - 0.60Si-0.28Cu-0.20Cr(6061-0) Annealed AMS-QQ-A-250/11A - cancelled - 2008M&P AMS 4026CE M080701SAEAluminum Alloy, Sheet and Plate 1.0Mg -0.60Si-0.28Cu-0.20Cr (6061;-T4 Sheet, T-451 Plate)Solution Heat Treated and Naturally AgedAMS-QQ-A-250/11A - cancelled - 2008M&P AMS4027Aluminum Alloy,Sheet and Plate1.0Mg-0.60Si-0.28Cu-0.20Cr(6061;-T6Sheet,T-651Plate)AMS QQ A250/11A ll d2008195 196 197 198 199 200 201 202 203 204AMS 4027CE N080701SAEAluminum Alloy, Sheet and Plate 1.0Mg 0.60Si0.28Cu0.20Cr (6061;T6 Sheet, T651 Plate)Solution and Precipitation Heat TreatAMS-QQ-A-250/11A - cancelled - 2008M&P AMS 4037CN N030701SAEAluminum Alloy, Sheet and Plate 4.4Cu - 1.5Mg - 0.60Mn (2024; - T3 Flat Sheet, T351 Plate)Solution Heat TreatedM&P AMS 4080CN N091201SAE Aluminum Alloy, Drawn Seamless Tubing 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr (6061-O) Annealed M&P AMS 4081CC J080601SAEAluminum Alloy Tubing, Hydraulic, Seamless, Drawn, Round 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr(6061-T4) Solution Heat Treated and Naturally AgedM&P AMS 4083BW K000901SAEAluminum Alloy Tubing, Hydraulic, Seamless, Drawn, Round 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr-(6061-T6) Solution and Precipitation Heat TreatedM&P AMS 4086BL N060901SAEAluminum Alloy, Drawn, Round, Seamless Hydraulic Tubing 4.4Cu-1.5Mg-0.60Mn (2024-T3)Solution Heat Treated, Cold Worked, and Naturally AgedM&P AMS 4088BT K070301SAEAluminum Alloy, Drawn, Seamless Tubing 4.4Cu-1.5Mg-0.60Mn (2024-T3) Solution Heat Treatedand Cold WorkedM&P AMS 4107F051101SAE Alum Aly Die Forg, (7050-T14)M&P AMS 4113CH E030701SAEAluminum Alloy, Extruded Profiles 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr (6061-T6) Solution andPrecipitation Heat TreatedM&P AMS 4116CN H090701SAEAluminum Alloy, Bars, Rods, and Wire 1.0Mg - 0.60Si - 0.3Cu - 0.20Cr (6061-T4) Cold Finished,Solution Heat Treated and Naturally AgedM&P1Specification Status Change Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy205 206 207AMS 4117CM J090701SAEAluminum Alloy, Rolled or Cold Finished Bars, Rods, and Wire and Flash Welded Rings 1.0Mg -0.60Si - 0.28Cu - 0.20Cr (6061; - T6, -T651) Solution and Precipitation Heat TreatedM&P AMS 4119Cancelled CN Can900101SAEAluminum Alloy Bars, Rolled, Drawn, or Cold Finished 4.4Cu - 1.5Mg - 0.60Mn (2024-T351) StressRelief StretchedAMS 4120M&P AMS 4120R020901SAEAluminum Alloy, Rolled or Cold Finished Bars, Rods, and Wire 4.4Cu - 1.5 Mg - 0.60Mn (2024)Solution Heat Treated and Naturally Aged (T4) Solution Heat Treated, Cold Worked, and NaturallyAged (T351)M&P AMS4121Aluminum Alloy Bars, Rods, and Wire, Rolled or Cold Finished 4.5Cu - 0.85Si - 0.80Mn - 0.50Mg208 209 210 211 212 213 214 215 216AMS 4121CA H071101SAE(2014-T6) Solution and Precipitation Heat TreatedM&P AMS 4123CN H060101SAEAluminum Alloy, Rolled or Cold Finished Bars and Rods (7075-T651) Solution and PrecipitationHeat TreatedM&P AMS 4124BU D050801SAEAluminum Alloy, Rolled or Cold Finished Bars, Rods, and Wire 5.6Zn-2.5Mg-1.6Cu-0.23Cr (7075-T7351) Solution Heat Treated, Stress Relieved by Stretching and OveragedM&P AMS 4128CN D071001SAEAluminum Alloy Bars, Rolled or Cold Finished 1.0Mg - 0.60Si - 0.30Cu - 0.20Cr (6061-T451)Solution Heat Treated and Stress Relieved by StretchingM&P AMS 4132CF F081201SAEAluminum Alloy, Die and Hand Forgings, Rolled Rings, and Forging Stock 2.3Cu-1.6Mg-1.1Fe-1.0Ni-0.18Si-0.07Ti (2618-T61) Solution and Precipitation Heat TreatedM&P AMS 4133CN E090301SAEAluminum Alloy Forgings and Rolled Rings 4.4Cu -0.85Si -0.80Mn - 0.50Mg (2014-T6) Solutionand Precipitation Heat TreatedM&P AMS 4135Cancelled CN Can860401SAEAluminum Alloy Forgings 4.5Cu - 0.85Si - 0.80Mn - 0.50Mg (2014-T6) Solution and PrecipitationHeat TreatedAMS 4133M&P AMS 4141CE F081001SAEAluminum Alloy Die Forgings 5.6Zn - 2.5Mg - 1.6Cu - 0.23Cr (7075-T73) Solution and PrecipitationHeat TreatedM&P AMS 4144BN F060501SAEAluminum Alloy, Hand Forgings and Rolled Rings 6.3Cu - 0.30Mn - 0.18Zr - 0.10V - 0.06Ti (2219-T852/T851) Solution Heat Treated, Mechanically Stress Relieved, and Precipitation Heat-TreatedM&P AMS 4149D020901SAEAluminum Alloy, Die and Hand Forgings 5.6n - 2.5Mg - 1.6Cu - 0.23Cr (7175-T74) Solution andPrecipitation Heat TreatedM&P217218219220 221 222 223 224 225 226 227 228 229230Precipitation Heat TreatedAMS 4150CN L030801SAEAluminum Alloy, Extrusions and Rings 1.0Mg - 0.60Si - 0.28Cu - 0.20Cr - (6061-T6) Solution andPrecipitation Heat TreatedM&P AMS 4162D030701SAEAluminum Alloy, Extrusions 6.3Cu - 0.30Mn - 0.18Zr - 0.10V - 0.06Ti (2219-T8511) SolutionTreated, Stress Relief Stretched, Straigtened, and Precipitation Heat TreatedM&P AMS 4173CN E030701SAEAluminum Alloy, Extrusions 1.0Mg - 0.60Si - 0.30Cu - 0.20Cr (6061-T6511) Solution HeatTreated,Stress Relieved by Stretching, Straightened, and Precipitation Heat TreatedM&P AMS 4181C030401SAE Aluminum Alloy, Welding Wire 7.0Si - 0.38Mg - 0.10Ti (4008) (UNS A94008)M&P AMS 4182CN G091201SAE Alum Aly Wire, Annealed 5.0Mg - 0.12Mn - 0.12Cr (5056-0) Annealed M&P AMS 4185D000701SAE Fill Mtl, Alum Braz,12SI,(4047)M&P AMS 4188Cancelled Can861001SAE Wldg Wire AMS 4181M&P AMS 4188Cancelled Can861001SAE Wldg Wire AMS 4233M&P AMS 4188Cancelled Can861001SAE Wldg Wire AMS 4244M&P AMS 4188Cancelled Can861001SAE Wldg Wire AMS 4245M&P AMS 4188Cancelled Can861001SAE Wldg Wire AMS 4246M&P AMS 4210CN K050301SAE Aluminum Alloy, Castings 5.0Si - 1.2Cu - 0.50Mg (355.0-T51) Precipitation Heat Treated M&P AMS 4212CN J051001SAEAluminum Alloy Castings 5.0Si - 1.2Cu - 0.50Mg (355.0-T6) Solution and Precipitation HeatTreatedM&P AMS 4214CN J080601SAECastings, Aluminum Alloy Sand 5.0Si - 1.2Cu - 0.50Mg (355.0 T71) Solution Heat Treated andOveragedM&P231 232 233 234 235 236 237 238 239 240 241O e agedAMS 4215CN H080301SAEAluminum Alloy, Castings 5.0Si - 1.2Cu - 0.50Mg (C355.0-T6) Solution and Precipitation HeatTreatedM&P AMS 4217CN H070401SAEAluminum Alloy, Castings 7.0Si - 0.32Mg (A356.0-T6) (Formerly T6P Temper) Solution andPrecipitation Heat TreatedM&P AMS 4218CN J100101SAEAluminum Alloy Castings 7.0Si-0.35Mg (A356.0-T6) (Formerly T6P Temper) Solution andPrecipitation Heat TreatedM&P AMS 4223CN D070401SAEAluminum Alloy, Castings 4.5Cu - 0.70Ag - 0.30Mn - 0.25Mg - 0.25Ti (A201.0-T4) Solution HeatTreated and Naturally AgedM&P AMS 4224Cancelled no s/s spec CN C100101SAEAluminum Alloy Castings, Sand 4.0Cu - 2.1Ni - 2.0Mg - 0.30Cr - 0.30Mn - 0.13T - 0.13V (243.0)Stabilizedok to use canc spec M&P AMS 4225CN D070601SAEAluminum Alloy, Heat Resistant, Castings 5.0Cu - 1.5Ni - 0.25Mn - 0.25Sb - 0.25Co - 0.20Ti -0.20Zr (203.0-T6) Solution Heat Treated and Precipitation Heat TreatedM&P AMS 4226Noncurrent CN A830101SAEAluminum Alloy Castings, High Strength 5.0Cu - 0.35Mn - 0.18Zr- 0.10V (224.0) Solution andPrecipitation Heat Treated (Overaged)M&P AMS 4227Cancelled no s/s spec CN E050701SAE Aluminum Alloy, Casting, Sand, 8.0Cu 6.0Mg 0.50Mn 0.50Ni, As Cast ok to use canc spec M&P AMS 4229CN D010501SAEAluminum Alloy Castings, High Strength 4.5Cu - 0.7Ag - 0.30Mn - 0.25Mg - 0.25Ti (A201.0-T7)Solution Heat Treated and OveragedM&P AMS 4233C030301SAE Aluminum Alloy, Welding Wire 4.5 Cu - 0.70Ag - 0.30Mn - 0.25Mg - 0.25Ti (201) (UNS A02010)M&P1Specification Status Change Made atBPS4000 revRev revDate Attachments Org Title supersededBy specialNotes latestSupersedingDoc reviewBy242 243 244 245AMS 4235CN B080301SAEAluminum Alloy Castings 4.6Cu - 0.35Mn - 0.25Mg - 0.22Ti (A206.0-T71) Solution andPrecipitation Heat TreatedM&P AMS 4236CN B070801SAEAluminum Alloy Castings 4.6Cu - 0.35Mn - 0.25Mg - 0.22Ti (A206.0-T4) Solution Heat Treated andNaturally AgedM&P AMS 4237Cancelled no s/s spec CN B070401SAEAluminum Alloy Castings, Sand 4.6Cu - 0.35Mn - 0.25Mg - 0.22Ti (206.0 - T71) Solution HeatTreated and Naturally Agedok to use canc spec M&P AMS 4241CN D091101SAEAluminum Alloy Castings 7.0Si - 0.58Mg - 0.15Ti -0.06Be (D357.0 - T6) Solution and PrecipitationHeat Treated Dendrite Arm Spacing (DAS) ControlledM&P AMS4244Aluminum Alloy,Welding Wire4.6Cu-0.35Mn-0.25Mg-0.22Ti for Welding A206.0Type Alloys246 247 248 249 250 251 252 253 254 255 256 257AMS 4244CE B080701SAE Aluminum Alloy, Welding Wire 4.6Cu 0.35Mn 0.25Mg 0.22Ti for Welding A206.0 Type Alloys M&PAMS 4245Noncurrent CR E100401SAE Aluminum Alloy, Welding Wire 5.0Si - 1.2Cu - 0.50Mg (355) (UNS A03550)M&P AMS 4246Noncurrent CP D080201SAE Aluminum Alloy, Welding Wire 7.0Si - 0.52Mg (357) (UNS A03570)M&PAMS 4260Not Acceptable to Useat Parker HannifinAerospaceCL G080601SAE Alum Aly Cast, Invest(356.0-T6)BPS4829AMS4260G unacceptable for Parker Use.BPS4829 created as replacement.M&P AMS 4261CN F091201SAE Aluminum Alloy Castings, Investment 7.0Si - 0.32Mg (356.0 - T51) Precipitation Heat Treated M&P AMS 4280CN J080601SAEAluminum Alloy Castings, Permanent Mold 5.0Si - 1.2Cu - 0.5Mg (355.0-T71) Solution HeatTreated and OveragedM&P AMS 4284CN H080601SAEAluminum Alloy Castings, Permanent Mold 7.0Si - 0.30Mg (356.0-T6) Solution and PrecipitationHeat TreatedM&P AMS 4289CN-011101SAEAluminum Alloy Castings 7.0Si - 0.55Mg - 0.12Ti (F357.0-T6) Solution and Precipitation HeatTreatedM&PAMS 4291CT H101001SAE Aluminum Alloy, Die Castings 8.5Si - 3.5Cu (A380.0-F) (See AS1990) As Cast M&PAMS 4315CK-050701SAEAluminum Alloy Sheet and Plate 5.6Zn - 2.5Mg - 1.6Cu - 0.23Cr 7075: (-T76 Sheet, -T7651 Plate)Solution and Precipitation Heat TreatedM&PAMS 4316CN-050701SAE Aluminum Alloy, Alclad Sheet and Plate 5.6Zn - 2.5Mg M&PAMS 4437CN E080501SAE Magnesium Alloy Castings, Sand 8.7Al - 0.70Zn (AZ91C-T6) Solution Heat Treated and Aged M&P258 259 260 261 262 263 264 265 266 267 268 269AMS 4507BW H011101SAE Copper Alloy (Brass), Sheet, Strip, and Plate 70Cu - 30Zn Half Hard (H02)M&P AMS 4510CN G010501SAE Phosphor Bronze, Sheet, Strip, and Plate 94.5Cu - 4.0Sn - 0.19P Spring Temper (H08)M&PAMS 4511A040701SAECopper Beryllium Alloy Castings 97Cu-2.1Be-0.52(Co+Ni)-0.28Si Solution and Precipitation HeatTreated (TFOO)M&P AMS 4530G050201SAE Copper -Beryllium Alloy Sheet, Strip, and Plate 98Cu - 1.9Be Solution Heat Treated (TB00)M&P AMS 4533CL C090701SAECopper-Beryllium Alloy, Bars and Rods 98Cu - 1.9Be Solution and Precipitation Heat Treated(TF00, formerly AT)-UNS C17200M&P AMS 4597CN-060801SAECopper-Nickel-Tin Alloy, Bars and Rods 77Cu - 15Ni - 8Sn Solution Annealed, Cold Finished andSpinodal Hardened (TX TS)M&PAMS 4631Noncurrent CL E880401SAE Aluminum Bronze Rods, Bars, and Forgings 90.5Cu - 7.5Al - 1.95: Stress Relieved M&PAMS 4633CL A031201SAEBronze, Aluminum Silicon, Rods, Bars, and Forgings 90Cu - 7.0Al - 1.8Si Drawn and StressRelieved (HR50)M&PAMS 4634CL B090301SAE Aluminum Bronze Bars, Rods, and Forgings 905Cu - 7.5Al - 1.9Si Stress Relieved M&P AMS 4635CL F090701SAE Aluminum Bronze Bars, Rods, and Forgings 87Cu - 9Al - 3Fe Stress Relieved M&P AMS 4640G050801SAEAluminum Bronze, Bars, Rods, Shapes, Tubes, and Forgings 81.5Cu - 10.0Al - 4.8Ni - 3.0FeDrawn and Stress Relieved (HR50) or Temper Annealed (TQ50)M&P AMS 4650L040301SAECopper-Beryllium Alloy, Bars, Rods, Shapes and Forgings 98Cu - 1.9Be Solution Heat TreatedTB00 (A)M&P270271 272 273 274 275 276 277 278279280281282283()AMS 4651CN C050701SAE Copper-Beryllium Alloy, Bars and Rods 98Cu - 1.9Be (CDA 172) Hard Temper (TD04)M&PAMS 4674CN G060901SAE Nickel - Copper Alloy, Corrosion-Resistant, Bars and Forgings 67Ni - 30Cu - 0.04S Free Machining M&PAMS 4701CN G091001SAE Copper Wire, Oxygen-Free 99.95 (Cu+Ag) Annealed M&P AMS 4730CN G080701SAE Nickel-Copper Alloy Wire, Corrosion-Resistant 67Ni-31Cu Annealed (400)M&P AMS 4765E990501SAE Braz Fill Mtl M&P AMS 4769F990501SAE Braz Fill Mtl M&P AMS 4770K990501SAE Braz Fill Mtl M&P AMS 4772J990501SAE Braz Fill Mtl M&P AMS 4774F990501SAE Braz Fill Mtl M&PAMS 4775CT J101001SAENickel Alloy, Brazing Filler Metal 73Ni - 0.75C - 4.5Si - 14Cr - 3.1B - 4.5Fe 1790 to 1970 °F (977 to1077 °C) Solidus-Liquidus RangeM&P AMS 4776CT H101001SAENickel Alloy, Brazing Filler Metal 73Ni - 4.5Si - 14Cr - 3.1B - 4.5Fe (Low Carbon) 1790 to 1970 °F(977 to 1077 °C) Solidus-Liquidus RangeM&P AMS 4777CT H101001SAENickel Alloy, Brazing Filler Metal 82Ni - 4.5Si - 7.0Cr - 3.1B - 3.0Fe 1780 to 1830 °F (971 to 999°C) Solidus-Liquidus RangeM&P AMS 4786CN H090701SAEGold-Palladium-Nickel Alloy, Brazing Filler Metal, High Temperature 70 Au - 8.0Pd - 22Ni 1845 to1915 °F (1007 to 1046 °C) Solidus-Liquidus RangeM&P AMS 4787F000401SAE Gold-Nickel Alloy, Brazing Filler Metal, High Temperature 70Au - 8.0Pd - 22Ni 1845 to 1915M&P。
罗弗公司2010年版低功耗高电压负压电子传输器2SB1182和2SB1240产品说明书
Medium power transistor (-32V, -2A)2SB1182 / 2SB1240●Features1) Low V CE(sat).V CE(sat) = -0.5V (Typ.) (I C /I B = -2A / -0.2A)2) Complements 2SD1758 / 2SD1862.●StructureEpitaxial planar type PNP silicon transistor●Absolute maximum ratings (Ta=25︒C)∗1 Single pulse, Pw =100ms∗2 Printed circuit board, 1.7mm thick, collector copper plating 100mm 2or larger.ParameterV CBO V CEO V EBO P C Tj Tstg−40V V V A(DC)W (Tc =25°C )W°C °C−32−5−2I CA (Pulse)−3101∗1∗22SB11822SB1240150−55 to 150Symbol Limits Unit Collector-base voltage Collector-emitter voltage Emitter-base voltage Collector currentCollector power dissipationJunction temperature Storage temperature●Electrical characteristics (Ta=25︒C)∗ Measured using pulse current.ParameterSymbol BV CBO BV CEO BV EBO I CBO I EBO h FE V CE(sat)f T CobMin.−40−32−5−−120−−−−−−−−10050−−−−1−1390−0.8∗∗−−V I C = −50μA I C = −1mA I E = −50μA V CB = −20V V EB = −4V I C /I B = −2A/ −0.2A V CE = −5V, I E =0.5A, f =100MHz V CB = −10V, I E =0A, f =1MHzV VμA μA −−V CE = −3V, I C = −0.5AV MHz pFTyp.Max.Unit Conditions−0.5Collector-base breakdown voltage Collector-emitter breakdown voltage Emitter-base breakdown voltage Collector cutoff current Emitter cutoff currentCollector-emitter saturation voltage DC current transfer ratio Transition frequency Output capacitance●Packaging specifications and h FEPackage CodeBasic ordering unit (pieces)TapingTL 2500h FE QR 2SB1182−TV22500−QR2SB1240Typeh FE values are classified as follows :Item h FEQ 120 to 270R 180 to 390●Electrical characteristic curvesFig.1 Grounded emitter propagationcharacteristicsBASE TO EMITTER VOLTAGE : V BE (V)C O L L E C T O R C U R R E N T : I C (m A )−−−−−−−−−−Fig.2 Grounded emitter outputcharacteristics−−−−−C O L LE C T O R C U R R E N T : I C (A )COLLECTOR TO EMITTER VOLTAGE : V CE (V)Fig.3 DC current gain vs.collector curren ( )D C C U R RE N T G A I N : hF ECOLLECTOR CURRENT : I C (mA)Fig.4 DC current gain vs.collector current ( )D C C U R RE N T G A I N : hF ECOLLECTOR CURRENT : I C (mA)Fig.5 Collector-emitter saturationvoltage vs. collector current ( )C O L L E C T O R S A T U R A T I O N V O L T A G E : V C E (s a t ) (m V )−−−−Fig.6 Collector-emitter saturationvoltage vs. collector current ( )−−−−−C O L L E C T O R S A T U R A T I O N V O L T A G E : V C E (s a t ) (m V )COLLECTOR CURRENT : I C (mA)Fig.7 Base-emitter saturation voltagevs. collector currentCOLLETOR CURRENT : I C (mA)B A S E S A T U R A T I O N V O L T A G E : V B E (s a t )(V )−−−−−Fig.8 Gain bandwidth product vs.emitter currentEMITTER CURRENT : I E (mA)T R A N S I T I O N F R E Q U E N C Y : f T (M H z )Fig.9 Collector output capacitance vs.collector-base voltageEmitter input capacitance vs. emitter-base voltageCOLLECTOR TO BASE VOLTAGE : V CB (V)EMITTER TO BASE VOLTAGE : V EB (V)C O L L E C T O R O U T P U T C A P AC I T A N C E : C o b (p F )E M I T T E R I N P U T C A P A C I T A N C E : C i b (p F )Fig.10 Safe operation area(2SB1182)−−−−−−−−−−C O L L E C T O R C U R R E N T : I C (A )COLLECTOR TO EMITTER VOLTAGE : V CE (V)NoticeN o t e sNo copying or reprod uction of this d ocument, in part or in whole, is permitted without theconsent of ROHM Co.,Ltd.The content specified herein is subject to change for improvement without notice.The content specified herein is for the purpose of introd ucing ROHM's prod ucts (hereinafter"Products"). If you wish to use any such Product, please be sure to refer to the specifications,which can be obtained from ROHM upon request.Examples of application circuits, circuit constants and any other information contained hereinillustrate the standard usage and operations of the Products. The peripheral conditions mustbe taken into account when designing circuits for mass production.Great care was taken in ensuring the accuracy of the information specified in this document.However, should you incur any d amage arising from any inaccuracy or misprint of suchinformation, ROHM shall bear no responsibility for such damage.The technical information specified herein is intended only to show the typical functions of andexamples of application circuits for the Prod ucts. ROHM d oes not grant you, explicitly orimplicitly, any license to use or exercise intellectual property or other rights held by ROHM andother parties. ROHM shall bear no responsibility whatsoever for any dispute arising from theuse of such technical information.The Products specified in this document are intended to be used with general-use electronicequipment or devices (such as audio visual equipment, office-automation equipment, commu-nication devices, electronic appliances and amusement devices).The Products specified in this document are not designed to be radiation tolerant.While ROHM always makes efforts to enhance the quality and reliability of its Prod ucts, aProduct may fail or malfunction for a variety of reasons.Please be sure to implement in your equipment using the Products safety measures to guardagainst the possibility of physical injury, fire or any other damage caused in the event of thefailure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHMshall bear no responsibility whatsoever for your use of any Product outside of the prescribedscope or not in accordance with the instruction manual.The Prod ucts are not d esigned or manufactured to be used with any equipment, d evice orsystem which requires an extremely high level of reliability the failure or malfunction of whichmay result in a direct threat to human life or create a risk of human injury (such as a medicalinstrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of anyof the Prod ucts for the above special purposes. If a Prod uct is intend ed to be used for anysuch special purpose, please contact a ROHM sales representative before purchasing.If you intend to export or ship overseas any Product or technology specified herein that maybe controlled under the Foreign Exchange and the Foreign Trade Law, you will be required toobtain a license or permit under the Law.Thank you for your accessing to ROHM product informations.More detail product informations and catalogs are available, please contact us.ROHM Customer Support System/contact/。
AZ MIF开发者的中文名字:高对比度、超高纯度TMAH基础开发者,适用于各种先进IC和厚层照相应用
APPLICATIONAZ MIF developers are high contrast, ultra-high purity tetramethyl-ammonium hydroxide (TMAH) based photoresist developers formulated for a wide range of advanced IC and thick photoresist applications. •Surfactant enhanced and surfactant free options •Industry leading normality control •Wide range of normality available•High purity, low particulate formulations•Multiple bulk and non-bulk packaging optionsPROCESSINGGENERAL PROCESSING GUIDELINESAZ MIF developers should be used at room temperature in puddle, spray, or batch immersion processing mode. Variations in develop time, developer temperature, and substrate temperature will result in inconsistent develop uniformity and will affect process repeatability/reproducibility. It is important to monitor and control these variables.When processed in batch immersion mode, MIF developer bath life will be limited by the volume of dissolved photoresist in solution and by carbonate uptake from the fab environment. Bath change out frequency should be specified by thenumber of substrates processed and by elapsed time since the last bath change. The maximum number of substrates that may be processed through a given bath will depend upon the photoresist thickness, the % of substrate surface covered, and the volume of the developer tank.MerckPeRFoRmaNce MaTeRIaLstechnical datasheet AZ® Organic DevelopersMetal Ion Free (TMAH) Photoresist DevelopersWhen not in use, developer tanks should be covered to minimize evaporation and the rate of carbonate uptake. Inert gas blankets (dry N2 for example) may also be used to isolate developer tanks from the fab environment. In general, immersion tanks should be changed at least every 24 hours (or sooner if the maximum number of substrates processed is reached).BATH AGITATIONMild agitation of immersion developer tanks may improve wafer-to-wafer develop uniformity and photo speed when batch processing substrates.PUDDLE DEVELOPINGDue to their lower surface tension, surfactant enhanced developers improve substrate wetting and facilitate puddle formation using lower dispense volumes than typical surfactant free developers. Complete development of patterns in thick photoresist films (> 3.0µm) may require multiple developer puddles. Increased normality developers and/or aggressive surfactants can improve dissolution rates and reduce develop time for thick photoresist films (see application guide section of this publication).RINSINGUse de-ionized water only to rinse wafers post develop and to “quench” the developer activity. Spray pressure or bath agitation during rinsing may reduce post develop defect density by minimizing redeposited surface particles.DEVELOPER APPLICATIONS GUIDE0.26N (2.38%) TMAH DEVELOPERS0.26N TMAH developers are the industry standard for advanced integrated circuit (IC) production and general lithography.AZ 300MIF DeveloperAZ 300MIF is an ultra-high purity, general purpose, surfactant free 0.26N TMAH developer featuring class leading normality control and ppb level metals content. Recommended for puddle, spray, and immersion applications.AZ 726MIF DeveloperAZ 726MIF is a surfactant enhanced 0.26N TMAH developer optimized for puddle develop processes.AZ 917MIF DeveloperAZ 917 MIF is a surfactant enhanced 0.26N developer formulated to improve photo speed in puddle or immersion develop processes with no loss of contrast or selectivity. Improves photo speed by 10-20% vs. AZ 726MIF.AZ 2026 MIF DeveloperAZ 2026 MIF developer contains different surfactants which also have an impact on dissolution rate of photoresist. Dark erosion is higher than with AZ 726 MIF, however this helps to avoid scrumming, which mainly is observed when the photoresist is processed on steppers without applying a post-exposure-bake (PEB).CUSTOM NORMALITY TMAH DEVELOPERSCustom normality developers may be desirable in cases where the develop rate or selectivity provided by 0.26N materials is inadequate. Reduced normality developers can improve selectivity to unexposed resist and increased normality developers will reduce the required exposure dose and/or develop time for thick resist processing.AZ 422 MIF DeveloperAZ 422 MIF developer is a reduced normality (0.215N) surfactant free developer engineered to maximize dissolution selectivity and process control.AZ 435MIF DeveloperAZ 435 MIF developer is a surfactant free, increased normality (0.35N) TMAH developer optimized to improve photo speed for medium thick photoresist processing (5-10µm thick) while maintaining good process control. Recommended for use with AZ 9200 and AZ P4000 series photoresists.AZ® Organic DevelopersAZ 405 MIF DeveloperAZ 405 MIF developer is an aggressive, surfactant enhanced, high normality developer (0.405N) designed for thick photoresist processing (>15µm thick). This developer provides a metal ion free alternative to the sodium or potassium based developers typically employed in thick resist processing. Recommended for use with AZ 9260, AZ 50XT, and AZ P4620 photoresists.AZ 2033 MIF developerAZ 2033 MIF developer contains high TMAH (3.0% TMAH), which is specially designed for improved compatibility with the AZ 8100 Series Photoresist.Developer Normality SurfactantAZ 300 MIF developer0.26N NoAZ 726 MIF developer0.26N YesAZ 927 MIF developer0.26N YesAZ 2026 MIF developer0.26N YesAZ 2033 MIF developer0.33N YesAZ 422 MIF developer0.215N NoAZ 435 MIF developer0.35N NoAZ 405 MIF developer 0.405N YesAZ 732c MIF developer0.30N YesProducts are warranted to meet the specifications set forth on their label/packaging and/or certificate of analysis at the time of shipment or for the expressly stated duration. EMD MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE REGARDING OUR PRODUCTS OR ANY INFORMATION PROVIDED IN CONNECTION THEREWITH. Customer is responsible for and must independently determine suitability of EMD´s products for customer’s products, intended use and processes, including the non -infringement of any third parties´intellectual property rights. EMD shall not in any event be liable for incidental, consequential, indirect, exemplary or special damages of any kind resulting from any use or failure of the products: All sales are subject to EMD’s complete Terms and Conditions o f Sale. Prices are subject to change without notice. EMD reserves the right to discontinue products without prior notice.EMD, EMD Performance Materials, AZ, the AZ logo, and the vibrant M are trademarks of Merck KGaA, Darmstadt, Germany.North America:EMD Performance Materials 70 Meister AvenueSomerville, NJ USA 08876(908) 429-3500Germany:Merck Performance Materials (Germany) GmbH Wiesbaden, Germany +49 611 962 4031Korea:Merck Performance Materials (Korea) Ltd.Seoul, Korea+82 2 2056 1316Singapore:Merck Performance Materials Pte. Ltd.Jurong East, Singapore +65 68900629Taiwan:Merck Performance Materials Co. Ltd.Hsinchu, Taiwan+886 3 5970885#375Japan:Merck Performance Materials G. K.Tokyo, Japan+81 3 5453 5062China:Merck Electronic Materials Shanghai, China+86 (21) 2083 2362AZ® Organic DevelopersMATERIALS COMPATIBILITY and HANDLINGTMAH containing developers are compatible with all standard semiconductor processing equipment designed to handle high pH aqueous solutions.Note: Contaminating inorganic developer baths or lines withtetramethylammonium hydroxide (TMAH) based metal-ion-free developers, even at the parts-per-million level, will neutralize the dissolution activity of the inorganic developer process. Use extreme caution when changing developing equipment from a metal-ion-free to an inorganic process.TMAH containing developers should be avoided in cases where slight etching of an aluminum layer cannot be tolerated. 0.26N TMAH developers will etch typical deposited aluminum substrate layers at ~100Å/min.Recommended personal protective gear during handling includes eye protection, apron, caustic resistant gloves. Refer to the current version of the SDS for information on exposure hazards. STORAGEStore AZ MIF Developers in a cool, dry location in sealed original containersaway from sunlight and incompatibles. Do not expose to excessive temperatures or moisture. Recommended storage temperature is >0C. Do not freeze. Empty containers may contain harmful residue. DISPOSALAZ MIF Developers are compatible with typical facility acid/base drain lines and materials. For disposal other than via facility solvent drains, refer to the current product SDS and to local regulations.。
异丁基三乙基硅烷
异丁基三乙基硅烷全文共四篇示例,供读者参考第一篇示例:异丁基三乙基硅烷(IBTES)是一种有机硅化合物,化学式为C11H26Si。
它具有许多优良的性质,使得它在工业和科研领域中得到广泛应用。
本文将介绍异丁基三乙基硅烷的性质、应用及制备方法,以帮助读者更加深入了解这种有机硅化合物。
1.性质异丁基三乙基硅烷是无色至淡黄色液体,在常温下为不挥发性、无毒的化合物。
它具有低表面张力、良好的润湿性和耐高温性,且对大多数溶剂稳定。
这些性质使得异丁基三乙基硅烷成为一种优良的表面活性剂和助剂,并广泛用于化妆品、润滑油、涂料等领域。
2.应用(1)在化妆品中,异丁基三乙基硅烷常用作乳化剂、增塑剂和润滑剂,能够使化妆品具有良好的光滑感和质感,提高产品的稳定性和延展性。
(2)在润滑油领域,异丁基三乙基硅烷可用作添加剂,提高润滑油的抗磨损性能和高温稳定性,延长机器设备的使用寿命。
(3)在涂料中,异丁基三乙基硅烷可以提高涂层的附着力和耐水性,同时增加涂层的柔韧性和表面光泽度。
3.制备方法异丁基三乙基硅烷的合成方法主要有硅烷烷化法和硅烷氢代法两种。
(1)硅烷烷化法:通过将三甲基氯硅烷和异丁烯在氯化铜的催化剂存在下发生反应,得到异丁基三乙基硅烷。
(2)硅烷氢代法:通过将三乙基氯硅烷和氯乙烷在氢氧化钠的存在下发生反应,得到异丁基三乙基硅烷。
第二篇示例:异丁基三乙基硅烷是一种有机硅化合物,化学式为C8H20Si。
它是一种链状的硅烷,分子中含有一个异丁基基团和三个乙基基团。
异丁基三乙基硅烷在化工领域具有广泛的应用,主要用作硅树脂和硅橡胶的交联剂,也可用作护发产品和皮肤护理产品的成分。
下面就让我们来深入了解一下这种有机硅化合物。
异丁基三乙基硅烷的物理性质:异丁基三乙基硅烷是一种无色液体,具有挥发性和易燃性。
它的熔点为-70°C,沸点为134°C,密度为0.726 g/cm3。
异丁基三乙基硅烷可溶于大多数有机溶剂,如乙醚、醇类和烃类溶剂。