压力阀PS10-31中文.pdf
施瓦格洛克 微调阀-S,M,L,31系列产品手册说明书
S, M, L, and 31 Series■Straight-pattern flow coefficients (C v) from 0.004 to 0.16■ Low- and high-pressure service■Repeatable vernier handles available■Brass and 316 stainless steel materials2 Needle and Metering ValvesT U B E F I T T I N G SP I P E , W E L D , V C R , V C O F I T T I N G SS T A N D A R D T U B I N GM O D U L A R S Y S T E M DH O S E / F L E X I B L E T U B I N GB E L L O W S , D I A P H R A G M V A L V E SB A L L & P L U G V A L V E S31C H E C K & R E L I E F V A L V E SR E G U L A T O R S & F I L T E R S I N S T R U M E N T M A N I F O L D S Y S T E M SM E A S U R E M E N T D E V I C E SR E F E R E N C E SM E D I U M - H I G H - P R E S S U R ELock screw “locks in” flowsettings (knurled andslotted handles)Guide O-ring enhances stemalignment (S series only)Tapered stem tip accurately controls gas and liquid flow ratesStem threads are isolated from system fluidHandle stop helps prevent damage to stem and orifice Stem O-ring contains system fluid➀ D ownstream pressure 500 psig (34.4 bar) max when valve requiresadjustment at pressure due to strength limitations of the fine-pitch threads and high operating torque.➁ S tainless steel L series valves are not recommended for shutoff in vacuum or gas service, or for repetitive shutoff in liquid service.S series valve shown.High-Pressure Valves (31 Series)■ Flow coefficient of 0.04; orifice of 0.062 in. (1.6 mm) ■ 316 SS bar stock body ■ Straight and angle patterns ■ Metal-to-metal shutoff ■ 2° stem taper (included angle)■ P anel mounting ■ Round phenolic handle■ Swagelok tube fitting and female NPT end connectionsPressure-Temperature RatingsRatings based on optional Grafoil ® packing.Ratings limited to 450°F (232°C) at 3435 psig (236 bar) with standard PTFE packing.Packing nut permits simpleexternal adjustment Packingfully contained by 316 SS glands to prevent extrusion 440C SSregulating stemhardened for enhanced service lifeaccurately controls gas and liquid flow ratesMetal-to-metal shutoff31 SeriesMetering Valves—S, M, L, and 31 Series 3Materials of ConstructionLow-Pressure Valves (S, M, and L Series)234568791a 1b2234488759913456891027High-Pressure Valves (31 Series)TestingEvery Swagelok S, M, and L series metering valve is factory tested with nitrogen at 1000 psig (69 bar). Shell testing is performed to a requirement of no detectable leakage with a liquid leak detector.Every Swagelok L series metering valve is tested for bubble-tight seat shutoff at 100 psig (6.8 bar) differential pressure.Every Swagelok 31 series needle valve is factory tested with nitrogen at 1000 psig (69 bar). Seats have a maximum allowable leak rate of 0.1 std cm 3/min.S Series M SeriesL SeriesWetted components listed in italics.➀ Anaerobic-type adhesive.➁ Straight and double-pattern M series valves.➂ A ngle and cross-pattern M series valves do not contain a body seal.1a Cleaning and PackagingSwagelok metering valves with VCR end connections areprocessed in accordance with Swagelok Special Cleaning and Packaging (SC-11) catalog , MS-06-63, to ensure compliance with product cleanliness requirements stated in ASTM G93 Level C .Swagelok metering valves with other end connections are processed in accordance with Swagelok Standard Cleaning and Packaging (SC-10) catalog, MS-06-62, special cleaning and packaging are available as an option.4 Needle and Metering ValvesM series valve shown.S series—0.16 in. (4.1 mm) maximum panel thickness.M and L series—0.13 in. (3.3 mm) maximum panel thickness.31 SeriesFor angle-pattern 31 series valves, add -A to the ordering number.Example: SS-31RS4-AMaximum Flow—0.16 C vMaximum Flow—0.04 C vStraight PatternMetering Valves—S, M, L, and 31 Series 5DimensionsDimensions, in inches (millimeters), arefor reference only and are subject to change.Angle PatternAngle Pattern6 Needle and Metering ValvesTUBEFITTINGSPIPE,WELD,VCR,VCOFITTINGSSTANDARDTUBINGMODULARSYSTEMDHOSE/FLEXIBLETUBINGBELLOWS,DIAPHRAGMVALVESBALL&PLUGVALVES31CHECK&RELIEFVALVESREGULATORS&FILTERSINSTRUMENTMANIFOLDSYSTEMSMEASUREMENTDEVICESREFERENCESMEDIUM-HIGH-PRESSUREDouble PatternS and M Series■ Inlet valve handle can be set andlocked at desired maximum flow.■ Outlet valve handle can be used forfine flow control up to the presetmaximum of the inlet valve.S series valve shown.Cross PatternS and M Series■ Fluid flows between side portsaround stem in any stem position.■ Flow through branch port can bemetered in both directions.Ordering Information and DimensionsSelect an ordering number. For brass valves, replace SS with B.Example: B-SS2-XDimensions are for reference only and are subject to change.M series valve shown.Options and AccessoriesMetering Valves—S, M, L, and 31 Series 7Colored Handles31 SeriesBlack phenolic handles are standard. To order colored phenolic handles, add a handle color designator to the ordering number.Example: SS-31RS4-BL Handle KitsHandle kits contain handle, brass insert, and instructions.To order a black phenolic handle, use kit ordering number PH-5K -14K-BK.For colored phenolic handles, replace -BK in the kit ordering number with a handle color designator.Example: PH-5K-14K -BLAdjustable-Torque HandleVernier HandleS, M, and L Series■ Enhances control for setting flows.■ Features PTFE packing and two top-mounted torque adjustment screws.■ Is available in stainless steel materialon stainless steel valves and in chrome-plated brass on brass valves, as standard.To order, add -OH to the ordering number.Example: SS-SS1-OHAdjustable-Torque Handle Kits Kits contain all parts necessary to add an adjustable-torque handle to an existing valve.Slotted HandleS and M Series■ Helps ensure repeatable flow adjustments.■ Provides readings accurate to1/25 turn.To order, add -VH to an S series ordering number or -MH to an M or L series ordering number.Examples:S S-SS1-VHSS-2MG -MH Vernier Handle KitsKits contain all parts necessary to add a vernier handle to an existing valve.■ Allows flow setting adjustment with ascrewdriver.■ Is for use in installations wherehandle is not easily accessible.■ Is available in stainless steel materialon stainless steel valves and in chrome-plated brass on brass valves, as standard.■ Allows valve to be panel mountedwithout removing handle.To order, add -SL to the ordering number.Example: SS-SS1-SLDimensions, in inches (millimeters), are for reference only and are subject to change.1.82 (46.2)open(21.0)A openM series valve shown.Slotted Handle KitsKits contain all parts necessary to add a slotted handle to an existing valve.1.42 (36.1)open(12.2)Options and Accessories8 Needle and Metering ValvesT U B E F I T T I N G SP I P E , W E L D , V C R , V C O F I T T I N G SS T A N D A R D T U B I N GM O D U L A R S Y S T E M DH O S E / F L E X I B L E T U B I N GB E L L O W S , D I A P H R A G M V A L V E SB A L L & P L U G V A L V E S31C H E C K & R E L I E F V A L V E SR E G U L A T O R S & F I L T E R SI N S T R U M E N T M A N I F O L D S Y S T E M SM E A S U R E M E N T D E V I C E S R E F E R E N C E SM E D I U M - H I G H - P R E S S U R E High-Temperature Stem Packing Material31 SeriesGrafoil packing extends the temperature rating to 850°F (454°C) and requires fluorinated tungsten disulfide-based lubricant. To order, add -G to the ordering number.Example: SS-31RS4-G Stem Packing KitsPTFE and Grafoil packing kits are available. Kits include packing, lubricant, and instructions. Select a kit ordering number.Special Cleaning and Packaging (SC-11)All SeriesSwagelok metering valves with VCR end connections are processed in accordance with Swagelok Special Cleaning and Packaging (SC-11) catalog , MS-06-63, to ensurecompliance with product cleanliness requirements stated in ASTM G93 Level C .To order special cleaning and packaging for metering valves with other end connections, add -SC11 to the valve ordering number.Example: SS-SS1-SC11Oxygen Service HazardsFor more information about hazards and risks of oxygen-enriched systems, refer to Swagelok Oxygen System Safety technical report, MS-06-13.MS-01-142, RevM, November 2021Options and Accessories• A packing adjustment may be required periodicallyto increase service life and to prevent leakage.• To increase service life, ensure proper valveperformance, and prevent leakage, apply only as much torque as is required to achieve positive shutoff in L and 31 series valves that are rated for shutoff service.IntroductionSince 1947, Swagelok has designed, developed, and manufactured high-quality, general-purpose and specialty fluid system products to meet the evolving needs of global industries. Our focus is on understanding our customers’ needs, finding timely solutions, and adding value with our products and services.We are pleased to provide this global edition of the book-bound Swagelok Product Catalog, which compiles more than 100 separate product catalogs, technical bulletins, and reference documents into one convenient, easy-to-use volume. Each product catalog is up to date at the time of printing, with its revision number shown on the last page of the individual catalog. Subsequent revisions will supersede the printed version and will be posted on the Swagelok website and in the Swagelok electronic Desktop Technical Reference (eDTR) tool.For more information, visit your Swagelok website or contact your authorized Swagelok sales and service representative.Safe Product SelectionWhen selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings,proper installation, operation, and maintenance are the responsibilities of the system designer and user.Warranty InformationSwagelok products are backed by The Swagelok Limited Life-time Warranty. For a copy, visit or contact your authorized Swagelok representative.Not all trademarks listed below apply to this catalog. Swagelok, Cajon, Ferrule-Pak, Goop, Hinging-Colleting,IGC, Kenmac, Micro-Fit, Nupro, Snoop, Sno-Trik, SWAK, VCO, VCR, Ultra-Torr, Whitey—TM Swagelok Company 15-7 PH—TM AK Steel Corp.AccuTrak, Beacon, Westlock—TM Tyco International Services Aflas—TM Asahi Glass Co., Ltd.ASCO, El-O-Matic—TM Emerson AutoCAD—TM Autodesk, Inc.CSA—TM Canadian Standards AssociationCrastin, DuPont, Kalrez, Krytox, Teflon, Viton—TM E.I. duPont Nemours and Company DeviceNet—TM ODVADyneon, Elgiloy, TFM—TM Dyneon Elgiloy—TM Elgiloy Specialty Metals FM —TM FM GlobalGrafoil—TM GrafTech International Holdings, Inc.Honeywell, MICRO SWITCH—TM Honeywell MAC—TM MAC ValvesMicrosoft, Windows—TM Microsoft Corp.NACE—TM NACE InternationalPH 15-7 Mo, 17-7 PH—TM AK Steel Corp picofast—Hans Turck KGPillar—TM Nippon Pillar Packing Company, Ltd.Raychem—TM Tyco Electronics Corp.Sandvik, SAF 2507—TM Sandvik AB Simriz—TM Freudenberg-NOKSolidWorks—TM SolidWorks Corporation UL—Underwriters Laboratories Inc.Xylan—TM Whitford Corporation © 2021 Swagelok Company。
气动阀说明书(中文)_100527
ZVP型气动薄膜调节阀产品说明书杭州哲达科技股份有限公司气动薄膜调节阀一、总体介绍ZVP系列气动薄膜精小型单座调节阀采用顶导向结构,配用多弹簧薄膜执行机构。
具有结构紧凑、重量轻、动作灵敏、流体通道呈~流线型、压降损失少、阀容量大、流量特性精确、拆装方便等优点。
广泛应用于精确控制各类无腐蚀性气体、液体、蒸汽等介质,工艺参数如压力、流量、温度、液位保持在给定值。
特别适用于允许泄漏量小、阀前后压差不大的工作场合。
本系列产品的公称压力等级有PN10、16、25、40,公称直径范围DN15~150。
适用流体温度为-25℃~+130℃至+180℃。
泄漏率为KVS值的0~0.02%,流量特性为线性和等百分比的组合。
设计单位及用户可根据具体工况进行选择。
本系列产品的阀体一般采用SIEMENS品牌产品。
二、工作原理图1 气动薄膜阀工作原理简图图1表示电-气阀门定位器的工作原理。
气动薄膜阀正常工作时,电-气阀门定位器从控制器或控制系统中接受DC4~20mA电流信号,转换成空气压力,向气动执行机构输送,从而来控制阀门的开度。
三、基本结构图2 气动薄膜阀基本结构图图中主要表示气缸执行机构和阀体的连接方式,结构配置还包括了电气阀门定位器、空气过滤器、减压阀、压力表等相关配件。
电气阀门定位器一般选用德国SIEMENS和韩国YTC品牌产品,或根据需要选用其他品牌的产品。
四、型号编制说明具体型号命名规则为ZVPa-bc d-efa—阀体系列号,有31、40、41、45、52、61共六个系列b—公称压力(×0.1MPa):10、16、25、40c—作用方式:K为气开式,B为气关式d—公称直径,DN15、DN50、DN150等e—流量系数(水介质)f—180℃高温蒸汽型用Z表示,130℃以下省略注:根据客户要求,具体配置以实物为准。
五、技术参数表1 技术参数表注1:弹簧范围:气开式优先选用40-200KPa及80-240KPa,气闭式优先选用20-100KPa及40-200KPa;可选用其它弹簧范围。
压力阀
溢流阀
减压阀
顺序阀
压力继电器
②溢流阀为内泄漏,而顺序阀需单独引出泄漏 通道,为外泄漏。 ③溢流阀的出口必须回油箱,顺序阀出口可接 负载。
第六章 液压阀-压力阀
顺序阀的应用 ①多缸动作回路
溢流阀
减压阀
顺序阀
压力继电器
第六章 液压阀-压力阀
顺序阀的应用 ②多串联在执行元 件的回油路上, 使回油具有一定 压力,保证执行 元件运动平稳, 作背压阀。
pc
k s xc A
顺序阀
开启压力
ks p c xc A
(调定压力)全流压力
压力继电器
pT
k s ( xc xR max ) A 2Cd wxR maxp cos
第六章 液压阀-压力阀
溢流阀
减压阀
顺序阀
压力继电器
第六章 液压阀-压力阀
溢流特性曲线
Cd Aw 2p q ( p pc ) ks 2Cd wp cos
溢流阀
减压阀
顺序阀
压力继电器
第六章 液压阀-压力阀
压力阀-减压阀 利用液流流经缝隙产生压力降的原理,使 阀的出口压力低于进口压力的压力控制阀。
溢流阀
减压阀
顺序阀
压力继电器
作用是用低液压系统中某一回路的油液压 力,使用一个油源能同时提供两个或几个不 同压力的输出。
第六章 液压阀-压力阀
压力阀-减压阀 按其控制压力分为 ①定值输出减压阀 (出口压力为定值) ②定比减压阀 (进口、出口压力比为定值) ③定差减压阀 (进口、出口压力差为定值)。
顺序阀
压力继电器
第六章 液压阀-压力阀
阀芯上的受力平衡
Fs pAxR p A 2Cd wxR cos
P系列单座调节阀
P系列单座调节阀应用:广泛应用于精确控制气体、液体等介质,工艺参数如压力、流量、温度、液位保持在给定值。
该系列产品有顶部导向型和套筒导向型两种结构,阀体结构紧凑、体积小、结构简单、流体通道呈S流线型;具有压降损失小、流量大、可调范围宽、流量特性曲线精度高、阀芯导向面积大、抗震性好等优点。
广泛应用于精确控制气体、液体等介质,工艺参数如压力、流量、温度、液位保持在给定值。
该系列调节阀可制成波纹管密封型、蒸汽夹套型、伸长型上阀盖等特殊结构。
杭州海沃流体控制设备有限公司A001 2013/09阀本体部分*型式:不平衡型阀芯*阀体及阀盖材质:WCB、WC6、LCB、CF8、CF8M*公称通径:15~200mm(1/2~8英寸)CF3、CF3M、哈氏C*阀芯形式:单座柱塞型*阀内件材质:0Cr18Ni9(304); 0Cr17Ni12Mo2(316)00Cr17Ni14Mo2(316L)*公称压力:PN 1.6、2.5、4.0、6.3、10.0MPa 以上+R.TFE(改性聚四氟乙烯) ANSI Class 150、300、600lb 以上+Stellite(堆焊司钛莱合金)JIS 10K、20K、30K、40K *上阀盖型式:标准型-30 ~ + 200℃*连接方式:法兰式(RF FM凹面RTJ)G系列散热型-60 ~ + 560℃螺纹式D系列低温型-196 ~ - 45℃焊接式【承插焊SW】J系列蒸汽夹套保温型*法兰标准:GB/T9113-2000 V系列波纹管密封型HG20592-97(HG/T20592-2009) *结构形式:顶部导向型单座调节阀HG20592-97(HG/T20592-2009) 套筒导向型单座调节阀ANSI B16.5 *填料:聚四氟乙烯V型填料*法兰端面距:GB/T12221-2005 柔性聚四氟乙烯填料柔性石墨填料*流量特性:*性能:金属阀座:等百分特性(%)和线性特性(L)*泄漏量:金属阀座:IV级(10-4×Kv)软阀座:等百分特性(%)和线性特性(L)(参见GB/T4213-2008)工作范围:司太莱堆焊的工作温度和压差参考图2 软阀座:VI级(参见GB/T4213-2008)软阀座的工作温度和压差参考图1执行机构部分杭州海沃流体控制设备有限公司A002 2013/09CV值和行程公称通径DN 20 25 32 40 50 65 80 100 125 150 200 线性 6.9 11 17.6 27.5 44 69 110 176 275 440 690 额定KV等百分比 6.3 10 16 25 40 63 100 160 250 400 630 额定行程L(mm) 16 25 40 60膜片有效面积(气动阀)280 400 600 1000 Ae(cm²)固有流量特性线性、百分比固有可调比50:1流量特性(IEC标准等百分比特性)流量特性的相对开度和对应流量(R=50)杭州海沃流体控制设备有限公司A003 2013/09软密封阀芯和堆焊司太莱合金阀芯的温度适用范围软阀座的工作温度和压差范围图1 堆焊司太莱合金的工作温度和压差范围图2备注:1、饱和蒸汽,热水等有可能产生腐蚀的场合,建议用金属密封;2、空化、闪蒸,禁油及要求保持关闭性能下的调节阀,不管工作温度和压差多大,建议堆焊司太莱合金3、空化和闪蒸或者水的温度超过100℃过热场合,建议用SUS440C硬化不锈钢。
5、压力阀
滑阀型导向结构
1-阀体 2-阀套 3-调压弹簧 4-销轴 5-阀芯 6-阀座 7-阻尼孔 8-弹簧座
8
直动式溢流阀工作原理
直动式溢流阀工作原理图
工作原理:压力油PE作用 在锥阀芯的下端,当液压力
Fhyd小于弹簧力FF时,锥阀芯 关闭,溢流阀没有溢流;随
着系统压力PE的升高,当Fhyd 大于弹簧力FF时,锥阀打开, 溢流阀溢流。
40
顺序阀控制系统
2
1
30bar
y1、y3+,1+ 2+
Y1
Y2
Y3
Y4
y2、y4+, 1-
2-
30bar
41
作平衡阀用
作用:放在执行元件的回油路上,平衡重物。
平衡重物,限制重物下落速度
42
作卸荷阀用
单向 阀的 作用
隔开 高低 压油 路不 必要 的联 系
高压泵
低压泵
43
压力继电器(压力开关)的结构和工作原理
座阀式具有快速响应的优点,这是由于以相当小的行 程移动量,就可产生相对较大的流量变化。
9
直动式溢流阀阻尼孔的作用
阻尼孔的作用:对阀芯的 运动形成阻尼,从而可避 免阀芯产生振动,提高阀 的工作平稳性。
导向、 缓冲装置
10
滑阀式溢流阀
遮盖行程
(死区行程)
11
实验室用直动式溢流阀
•型号:DBDH…K1X/… •压力等级:25至400bar (座阀式)
16
先导式溢流阀遥控口的作用
二级压力切换的应用
100 bar 50 bar
150 bar
Pressure setting 150 bar
萨姆森电动调节阀说明书
可提供按照DIN EN 14597标准经过型式检验的控制设备,按 要求可提供注册号。
图2· 3374型执行机构
图2 · 42-36 E型自力式流量控制阀 配置3374型执行机构
特殊类型 耐油型·最高温度220 oC 符合ANSI标准的类型按要求提供
表1给出组合型自力ຫໍສະໝຸດ 控制阀的不同类型及其典型应用,对于基型自力式控制阀的详情参见数据表T 3015 ZH.
典型应用
图3 · 42-36E型自力式流量控制阀间接安装在区域供热系统
图4 · 42-36E型自力式流量控制阀直接安装在区域供热系统
2
T 3018 ZH
表2 · 技术数据 · 阀 · 压力单位:巴
连接杆处的允许温度
-
详见…
T 8340 ZH
1) 按需求提供120V 或24V、50Hz或60Hz 2) 带加热
3374-15 无
2500 N
约 18VA 5 至 60 oC
T 8331 ZH
压力-温度图 – 按照DIN EN 12516-1
[巴]
自力式控制阀的应用范围和允许的压力和温度限制按照压力-温度 图和额定压力等级的规格,
24
40
120
22 mm 280 420 500
0.3
50至 120 75至 180
70至 180 100至 260
90至 220 120至 300
2423E型阀门 · 膜片平衡
公称通径
DN
125
150
KVS 值 z值
35mm行程
250
380
0.35
最大允许压差⊿p 对于水的流量设定点范围 m3/h
CCI调节阀样本中文
■ 高性能 ■ 动态响应 ■ 高速度 ■ 低死区,滞后
面积 50 113 200 313 400
行程 6” -12” -18” -24” -24”
产品摘要:阀门辅件
13
定位器
空气ห้องสมุดไป่ตู้作部件
电-气定位器(E/P)
输入:420mA 直流,交流低于 24V 附件:Exdm Ⅱ B(c)T6
Control Valve for General Application
2
CCI 的 840G/840H 系列调节阀拥有优良的控制性能和高可靠性
840 系列笼式调节阀采用了当前非常专业和先进的技术,广 泛应用于高压差下的较为清洁的流体和气体环境。调节阀适 合于水蒸气、流体和气体多种介质,阀芯成流开或流关两种 形式。其中流关适合于流体,流开适合于水蒸气和气体。
–30C ~300C
–196C ~230C
–196C ~565C
泄露 等级 Ⅵ Ⅳ,Ⅴ Ⅵ Ⅳ,Ⅴ
840 系列调节阀的分类 一级
阀体
840
球形
860
角形
830
三通
800
切断球形
二级
阀芯
G
笼式
H
钻孔套筒
T
三通(分流、合流)
D
标准的 DRAG
TBS
到
CCI Control Valves for General Applications
附件 多种规格适用
于不同需要
故障方式 标准类型是气关式, 也可以选择气开式, 也适用于膜片式,活 塞,液动及电动执行 机构
易改变的阀芯 所有阀内组件便 于检查和更换
多弹簧 多弹簧的设计提供了 非常小的滞后和死区
压力阀PS10-43中文.pdf
䬬䔜绬先㙡遙㆞ 筼┷⨚ 袛梏⨚稛☚欉矊梏 盶肺虱Ⓟ✛㇈譻睅茫肺秼㽈 牑㦘扫䲚稛虱㝜⇫┮賍 ℛ痒ₘ抩⨚҈ ⤲PS10-43⨚ ⦷☮眑瘶痒 蛭稛虱 㢅 茖幇㽈稛⦷㽈♲ ✛ 芠梃♛⚠税┷ ⚛㢅疭 鍫公 ㇈譻睅≬虚⦷㽈♲ 秼㽈 ㇢ ⮓䤓☚┪才瘸梏䤓欓幍⋋ 梏唾䲊┷ ⅝ 税⚠ ⺐桼 ⚛㢅 税⚠ 碟抩 㽷砽稛虱☚┪ ⮓䤓卛☚┯ₙ梏䤓欓幍☚┪➥◥庒唑遙糵ₜ芽礈茽梏⇢ 庒唑犀誑≬㇈譻ₜ芽缗☚⸭♾折䤓♾折☚┪喒⦃才 EDU SVL 梏唾✛梏眀䫻德⮓䚕 功䞷ぴ₩デ屓梏ⷣ➥҈ 喝 EDU SVL ≭䛻喝莋屐㊶賍⦍䘔⇰喝⦷㪖諜☚┪䤓 㢅 蜙⮶ 秧◖ ⒕朮 簌礀喀⺇ ⒕朮 㠯 喝 EDU SVL EDU SVL ⍕ 㠯 喝 㪖瘮ₐ受蟇厅蓒⺐ 䓳␐喝莋屐Ϸ䉔喝伧矑⅚ℝ F6W VVX 䤓䪎䓸㽈㒥牑㦘䀵袛⇫䞷䤓⚗㒟㽈 㷱喝蠼㦘腏Ⓟ 莋屐 䬬 喝9& 莋屐䬬 喝&7 ;; 莋屐 ㏰Т 喝6. ; %00 莋屐USASI:ISO:6.792.1げ㘩 ⅔㖖㙡ↅТ喝摜摞 NJ OEV 朱Ⓟ ぴ⇫槱䫻德⮓䚕 盶缂槱柏枛 蓒⺐ↅ ₐ受蟇厅 2 ⨚皽✛貆㺷鉽㖰皽 㪖瘮⨚ 棂㨐㺶荩杬⚗摠㓚㩓✛绬瞹䥥䬬 喝摜摞 NJ OEV䫻棂㨐㺶荩舊薦矑杬⚗摠 珩莓 7 欬着⋋才 EDU SVL 莋屐欄 㙟∪䚒犐枇材✛朱Ⓟ梏⧦㠨䤓 ⻉⺇♾賍ₜ⚛ 庆勣籏ぴ☑䄯㞮䔵Т ⺇␔⏼屡⯃ A 䦃㈓ ⺇ 杬⚗摠㓚㩓 B 折ↅ$ サ婉ヌ䥥 C ぴ☑欓函槭庒唑 F ぴ☑欓函椟塞庒唑 H 折ↅ& サ析兎ⷣL㠯4 Ⓙ EDU Ⓙ SVL 22 Ⓙ EDU Ⓙ SVL 6.792.2䃎䉓䬬 ⇥ ⅔帱徼㙡孔ↅ 0 6$( 6T 6$( 8T 喀⺇ %63 2B喀⺇ %63 3B%63 梏⧦ 8 . Ⓟ抯₢䞷 Тₐ受㳰厅 㪖N㺮㳰厅V䃪㒚(bar)g諽䤌 ♾庒唑㒥㖖⸩☚┪ √Ⱁ M25 EDU M100 EDU䃪㒚(psi)g諽䤌 ♾庒唑㒥㖖⸩☚┪ √Ⱁ 9.0 SVL 21.0 SVL PS10-43__ - __ __ __ - __ - __ __ / __ __ __ __。
PU PI 和 PS10 差压传感器说明书
Instruction ManualPU/PI and PS10Differential PressureTransducershalstrup-walcher GmbHStegener Straße 10D-79199 KirchzartenGermanyPhone: +49 (0) 76 61/39 63–0Fax: +49 (0) 76 61/39 63–99E-Mail: *************************Internet: Document 7100.001784 Version 5.3 02/2010PU/PI and PS10 Instruction ManualTable of Contents1 Safety precautions (4)1.1 Appropriate use (4)1.2 Shipping, assembly, electrical connections and start-up (4)1.3 Troubleshooting, maintenance, repairs, disposal (4)1.4 Symbols (5)2 Instrument description (6)3 Start-up (6)3.1 Features (6)3.2 Supply voltage connections in the instrument: (7)3.3 Analog output connections in the instrument (7)4 Calibrating the zero point (8)5 Troubleshooting (9)6 Technical data (10)7 Dimension drawings (12)PU/PI and PS10 Instruction ManualPurpose of instruction manualThis instruction manual describes the features of the PU/PI and PS10 differential pressure transducers and provides guidelines for their use.Improper use of this instrument or failure to follow these instructions may cause injury or equipment damage. Every person who uses the device must therefore read the manual and understand the possible risks. The instruction manual, and in particular the safety precautions contained therein, must be followed carefully. Contact the manufacturer if you do not understand any part of this instruction manual. Handle this manual with care:∙It must be readily available throughout the lifecycle of the instrument.∙It must be provided to any individuals who assume responsibility for operating the instrument at a later date.∙It must include any supplementary materials provided by the manufacturer.The manufacturer reserves the right to continue developing this instrument model without documenting such development in each individual case. The manufacturer will be happy to determine whether this manual is up-to-date.ConformityThis instrument corresponds to the state of the art and meets all legal requirements set forth in EC directives as evidenced by the CE label.© 2005The manufacturer owns the copyright to this instruction manual. This manual contains data, instructions and drawings pertaining to the features and usage of this instrument; copying this manual in part or in full or distributing it to third parties is prohibited.PU/PI and PS10 Instruction Manual1 Safety precautions1.1 Appropriate useIn addition to differential pressure data, the PU/PI and PS10 differential pressure transducers also record positive and negative overpressures.Always observe the operating requirements—particularly the permissible supply voltage—indicated on the rating plate and in the "Technical data” section of this manual.The instrument may only be handled as indicated in this manual. Modifications to the instrument are prohibited. The manufacturer is not liable for damages caused by improper use or failure to follow these instructions. Violations of this type render all warranty claims null and void.1.2 Shipping, assembly, electrical connections and start-upDo not close the pressure inputs when shipping, as changes in barometric pressure could damage instruments with low measuring ranges.Only technical personnel who are appropriately trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections.The instrument may only be operated by appropriately trained individuals who have been authorized by the operator of the facility.Pressurized air or breath is not to be used for performance tests, as this could damage instruments with low measurement ranges.Measurement errors may occur if the instrument is not kept protected from sunlight. Specific safety precautions are given in individual sections of this manual.1.3 Troubleshooting, maintenance, repairs, disposalThe individual responsible for the electrical connections must be notified immediately if the instrument is damaged or if errors occur that cannot be corrected as indicated in section 5.This individual must take the instrument out of service until the error has been corrected and ensure that it cannot be used unintentionally.Always unplug the supply voltage before opening the instrument!This instrument requires no maintenance.Only the manufacturer may perform repairs that require the housing to be opened.PU/PI and PS10 Instruction ManualThe electronic components of the instrument contain environmentally hazardous materials and materials that can be reused. For this reason the instrument must be recycled in accordance with the environmental guidelines of the jurisdiction in question once it has been taken permanently out of service.1.4 SymbolsThe symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards:WARNING! This warns you of a potential hazard that could lead to bodily injury up to and including death if the corresponding instructions are not followed.WARNING: This warns you of a potential hazard that could lead to significant property damage if corresponding instructions are not followed.INFORMATION This indicates that the corresponding information is important for operating the instrument properly.PU/PI and PS10 Instruction Manual2 Instrument descriptionThe PU/PI and PS10 pressure transducers are pneumatic, electronic sensors for measuring overpressures, vacuum pressures and differential pressures. Typical applications include, for instance, pressure measurements in air-conditioning and ventilation ducts. At the heart of the transducer is a pressure measurement capsule with a beryllium bronze membrane spring, which is displaced by the pressure difference between the two chambers of the measurement capsule. Inductive displacement transducers measure membrane deflection without contacting the membrane. The instrument has no frictional parts or parts subject to mechanical wear.3 Start-up3.1 FeaturesAlthough the PU/PI and PS 10 pressure transducers are highly robust, they are nevertheless precision instruments and should be handled with care. Avoid mounting the instruments in the direct vicinity of any sources of radiation or heat, such as heaters, as this could result in measurement errors. Ideally, the instrument should be mounted vertically on a wall not subject to vibration. Pressure (+) and vacuum (-) ports should be pointing down in order to prevent any condensation from entering the measurement cell.When connecting pressure to the transducer, use the following table to ensure that the sign of the pressure (+ or -) is correct.PU/PI and PS10 Instruction Manual3.2Supply voltage connections in the instrument:Figure 1: Configuration of circuit board: (not all components are shown)P0Observe the required supply voltage (see rating plate) as well as the connection diagram located on the housing cover / circuit board mount. 3.3Analog output connections in the instrumentThe transducer outputs are protected from short circuits. Instruments supplied with direct current are also protected from reverse polarityPU/PI and PS10 Instruction ManualDisplay-connector4 Calibrating the zero pointPlease remember that it takes roughly 30 to 60 minutes for the pressuretransducer to warm up after it is switched on. The output signal may notremain stable during this period.It is recommended that the zero point after a long operating time(approximately 6 months) is checked and if necessary calibrate it again.The wiring of the current outputmakes it impossible to enter a negative current.As a result, operators cannot turn the zero-point potentiometer beyond the0.0 mA mark when calibrating the zero point. Were this not the case, thenegative component, which cannot be displayed, would interfere with theoutput signal.After the pressure transducer has warmed up, the operator may calibrate the zeropoint using the P0 trimmer (see figure 1). The following table may be used to look up the value to which the analog output must be set when the ports are open; this value is dependent upon both the measurement range and the output signal.PU/PI and PS10 Instruction Manual 5 TroubleshootingPU/PI and PS10 Instruction Manual 6 Technical dataPU/PI and PS10 Instruction ManualAppendix A: Parts in contact with measurement medium∙ Beryllium bronze CuBe2 ∙ Araldite CY236 / HY988∙ Mu metal (nickel alloy) ∙ Loctite 242e∙ Brass CuZn39Pb3 ∙ Carbonyl iron∙ Aluminum AlCuMgPb / AlMg3 ∙ KEL (FPM: fluorinated rubber) ∙ Silicon (tubing) optional: Viton ∙ Vepuran Vu 4457/51∙ Crastin (PTBP) ∙ UHU-Plus endfest 300 binder。
压力解压三口阀与锁孔模型说明书
Doc. No. VH*-OMQ0023-CPressure Relief 3 Port Valve With Locking HolesVHS20-(F,N)01~02A,B(-B,S)(-K,R,Z)VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z)VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)VHS40-(F,N)06A,B(-B,S)(-K,R,Z)VHS50-(F,N)06~10A,B(-B,S)(-K,R,Z)VHS2510-(F,N)01~02A,B(-B,S)(-K,R,Z)VHS3510-(F,N)02~03A,B(-B,S)(-K,R,Z)VHS4510-(F,N)02~04A,B(-B,S)(-K,R,Z)VHS4510-(F,N)06A,B(-B,S)(-K,R,Z)VHS5510-(F,N)06~10A,B(-B,S)(-R,Z)PAGE 1. SAFETY INSTRUCTIONS 1~52. APPLICATION 63. SPECIFICATIONS6~74. HOW TO ORDER 7~85. CONSTRUCTION / PARTS LIST9~106. OPTIONAL ASSEMBLY117. DIMENSIONS12~13With Locking HolesSafety InstructionsThese safety instructions are intended to prevent hazardous situations and/or equipment damage.These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations.*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. ISO 4413: Hydraulic fluid power -- General rules relating to systems.IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. etc.Caution Caution indicates a hazard with a low level of risk which, if not avoided, could resultin minor or moderate injury.Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.DangerDanger indicates a hazard with a high level of risk which, if not avoided, will resultin death or serious injury.Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment ordecides its specifications.Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results.The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product.This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly.The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautionsof all relevant products carefully.3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.3. An application which could have negative effects on people, property, or animals requiring special safety analysis.e in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.With Locking HolesSafety InstructionsCaution1.The product is provided for use in manufacturing industries.The product herein described is basically provided for peaceful use in manufacturing industries.If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary.If anything is unclear, contact your nearest sales branch.Limited warranty and Disclaimer/Compliance RequirementsThe product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.Read and accept them before using the product.Limited warranty and Disclaimer1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.∗2)Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.2. For any failure or damage reported within the warranty period which is clearly our responsibility,a replacement product or necessary parts will be provided.This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.∗2) Vacuum pads are excluded from this 1 year warranty.A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.Also, even within the warranty period, the wear of a product due to the use of the vacuumpad or failure due to the deterioration of rubber material are not covered by the limitedwarranty.Compliance Requirements1. The use of SMC products with production equipment for the manufacture of weapons of massdestruction (WMD) or any other weapon is strictly prohibited.2. The exports of SMC products or technology from one country to another are governed by therelevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.2. ApplicationsThis product is a residual pressure release valve which is switched by hand.3. Standard specifications(1) Single action type(2) Double action typeNote 1) Supply pressure: 1.0 MPaModel VHS20VHS30VHS40VHS40-06VHS50FluidAirAmbient and fluid temperature -5 to 60o C (No freezing)Proof pressure1.5MPa Operating pressure range 0.1 to 1.0MPa Color (Standard) Handle: Red Body: WhiteHandle operationPushing stroke -- Switching angle 90o Handleoperating force Push force Note1)-Rotating torqueNote1) 0.7N-m or less 1.0N-m or less 3.0N-m or less 3.0N-m or less 3.5N-m or less Mass (Handle /Bonnet material) A (Flameresistant PBT )76g 127g 247g 293g 532g B (Aluminum) 92g156g301g349g630gModel VHS2510 VHS3510 VHS4510 VHS4510-06 VHS5510FluidAirAmbient and fluid temperature -5 to 60o C (No freezing)Proof pressure1.5MPa Operating pressure range 0.1 to 1.0MPa Color (Standard) Handle: Red Body: WhiteHandle operationPushing stroke 3.2mm4.2mmSwitching angle 90o Handleoperating force Push force Note1)10N or lessRotating torqueNote1) 0.7N-m or less 1.0N-m or less 3.0N-m or less 3.0N-m or less 3.5N-m or less Mass (Handle / Bonnet material) A (Flameresistant PBT )77g 129g 250g 296g 536g B (Aluminum) 93g158g304g352g635gFlow characteristicsModelPort size Supply (IN→OUT)Exhaust (OUT→EXH)IN, OUT EXH C(dm3/S-bar) b Cv C(dm3/S-bar) b CvVHS20 VHS2510 1/81/82.4 0.43 0.65 2.5 0.39 0.69 1/43.3 0.40 0.88 3.1 0.51 0.84VHS30 VHS3510 1/41/46.4 0.45 1.7 6.2 0.38 1.7 3/8 8.3 0.41 2.37.0 0.41 1.9VHS40 VHS4510 1/43/87.3 0.49 2.0 8.5 0.35 2.3 3/8 10.9 0.45 3.0 11.6 0.40 3.1 1/2 14.2 0.39 3.8 13.3 0.43 3.6VHS40-06VHS4510-063/4 1/2 18.3 0.31 5.0 17.7 0.37 4.8VHS50 VHS5510 3/41/223.8 0.41 6.4 21.80.41 5.91 31.9 0.33 8.6 23.5 0.44 6.4 4. How to Order(1) Single action typeS: Assembled for shipping(2) Double action type# For connection of the modular type FRL combination, the spacer or the spacer with bracket shown below is necessary. Please order separately.* New VHS series compatible with Old spacer Y200(T) to Y600(T) and Old AC20 to AC60.3-port valve for residualpressure release Spacer p/n With bracket Spacer p/n Applicable air combination VHS20, VHS2510 Y200-A Y200T-A AC20-AVHS30, VHS3510 Y300-A Y300T-A AC25-A, AC30-A VHS40, VHS4510 Y400-A Y400T-A AC40-A VHS40-06, VHS4510-06 Y500-A Y500T-A AC40-06-A VHS50, VHS5510 Y600Y600TAC50, AC55, AC60Spacer Spacer with bracket5. Construction/Parts list(1) StandardNo. Description MaterialNoteVHS20~50-A VHS2510~5510-AVHS20~50-B VHS2510~5510-B1BodyADC12White 2BonnetFlame resistant PBT(Equivalent to UL-94 Standard V-0) ADC12White3 Handle Flame resistant PBT(Equivalent to UL-94 Standard V-0)ADC12Red4 Cam ring POM -5 Spool PBT -6 Spool O-ring H-NBR -7 Spool spring Stainless steel- 8 SleevePOM-* VHS series cannot be disassembled. No repair parts available.VHS20~50-A VHS2510~5510-A VHS20~50-B VHS2510~5510-B-9-(2) Optional specificationsOptional parts3-port valve for residualpressure release Bracket assembly p/n Silencer assembly p/n VHS20, VHS2510 VHS20PW-180AS VHS20PW-190AS VHS30, VHS3510 VHS30PW-180AS VHS30PW-190AS VHS40, VHS4510 VHS40PW-180AS VHS40PW-190AS VHS40-06, VHS4510-06 VHS40PW-180-06AS VHS40PW-190-06AS VHS50, VHS5510 VHS50PW-180ASVHS50PW-190AS-10-Option B With bracketOption SBuilt-in Silencer (EXH port)6. Assembly of Optional parts-11-7. Dimensions(1) Single action type-12-VHS40~50VHS30VHS20(2) Double action type-13-VHS4510~5510VHS3510VHS2510Rev. A - Semi-standard "K" type added (Blackhandle)- Revision of safety precaution (Piping /Installation and Adjustment / OperatingEnvironment)- Revision of the product number ofspacer, addition of interchangeability ofold and new products- Addition of noise reduction effect ofsilencer assemblyRev. B - Revision of the figure of dimension forVHS20/VHS2510.- Revision of the dimension “I” forVHS20/VHS2510 in the dimension table.Rev. C – Update the photos of Spacer and Spacerwith bracket to the latest version.– Update the Construction to the latestversion.– Correct Silencer assembly P/N4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPANTel: + 81 3 5207 8249 Fax: +81 3 5298 5362© 2019 SMC Corporation All Rights Reserved。
OPW 301 紧急泄压阀说明书
Materialsand ListingsOPW 301Emergency VentsThe OPW 301 Emergency Vent isLid: Cast iron with AST Phase 1 Enhanced Vapor Recovery (EVR) SystemTable 1Emergency Venting Size Selection GuideFor Horizontal Above Ground Storage TanksThe OPW AST Venting Guide is supplied to assist emergency venting selection for above ground storage tanks (AST). The table below contains common tank sizes and based on the Wetted Area of a horizontal cylindrical storage tank, the correct size OPW Emergency Vent . The following chart, was taken directly from NPFA 30 and UL 142.Horizontal AST Emergency Venting Size Guide – Table 1Capacity Diameter LengthWetted Area Required Vent Capacity OPW 301 Vent SizeGallons Liters ft. or in.Meters ft. or in.Meters sq. ft.sq. m.CFH CMHHorizontal AST Emergency Vent SelectionFor Horizontal Above Ground Storage TanksTABLE 1 is a pre-calculated chart that may have all the information needed to choose the proper emergency vent. If the tank size is not in the pre-calculated chart, use the example below as a guide to figure out the wetted area, cubic feet per hour (CFH), and proper vent selection for the particular tank.**EXAMPLE:Given: Tank capacity is 10,000 gallons; 10 feet in diameter x 17 feet long.Step 1From TABLE 1: WA = 518 sq. ft.If not in the table, do the following to calculate the wetted area:p d24p d 22Formula: WA=.75 2 + pdl =.75 + pdlWA = wetted area in square feet75% = horizontal tank factor p = 3.14d = diameter of tank end in feet l = length of tank in feet3.14 x1022WA=.75 + (3.14 x 10 x 17)WA=.75 (157.0 + 533.8) = 518 square feet rounded Step 2If the tank size is in the chart, use the supplied CFH values to determine theemergency vent size needed in TABLE 1.If not in the charts, continue the following example:Using 518 square feet, the cubic feet per hour (CFH) can be found using TABLE 1.Since 518 falls between the values of 500 and 600, interpolation is necessary as follows:See TABLE 2 for additional CFH values.600 sq. ft. 392,000 CFH -500 sq. ft. -354,000 CFH Difference: 100 sq. ft.38,000 CFH38,000 x100518-500; x =6,840 CFHTotal CFH required = 354,000 CFH + 6,840 CFH = 360,840 CFH Step 3Vent selection: using TABLE 1, find the range in which 360,840 CFH falls. The tables show that an 8" emergency vent is needed. **PEI Recommended Practices 200-96Wetted Area vesus Cubic Feet of Free Air Per Hour Table 2(14.7 PSIA and 60°)SOURCE: Flamable and Combustible Liquids Code 30, NFPA.Interpolate for immediate values.。
压力阀SQDB中文.pdf
全调5转
+-
b
c
3 排油
2 顺序口
进油 1
定位肩部
流量
a
60 L/min.
120 L/min.
240 L/min.
480 L/min.
( 代表 ) 插式阀
型号 pna_ Ó i^k pnc_ Ó i^k pne_ Ó i^k png_ Ó i^k
插孔
T - 11A T - 2A T - 17A T - 19A
插式阀尺寸
c
a
b
i
`
h
34,9 22,2
64
66
70
34,9 28,6
72
74
78
46
31,8
84
86
90
63,5 41,3 100 104 107
安装 扭矩 (Nm) 40/50
60/70
200/215
465/500
性能曲线
P = bar P = bar P = bar
pna_
pnc_
pne_
png_
Flow = L/min.
■ 最大工作压 = 350 bar ■ 最大漏油量 = SQDB: 32,8 cc/min./70 bar, SQFB: 49,2 cc/min./70 bar ,
SQHB: 65,5 cc/min./70 bar, SQJB: 81,9 cc/min./70 bar
■ 响应时间 = 25 ms ■ 油口 3 的压力直接加于阀的设定压并不超过 350 bar. ■ 必须停止油流才能使阀回座关闭 .
选购规格
流量 a 60 L/min. c 120 L/min. e 240 L/min. g 480 L/min.
Omega PSW31系列电子压力开关用于气动应用说明书
User’s Guidee-mail:**************PSW31 SERIES ELECTRONIC PRESSURE SWITCH FOR PNEUMATIC APPLICATIONSOMEGAnet®On-Line Service Internet e-mail**************Servicing North America:USA:One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford, CT 06907-0047TEL: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec) H7L5A1TEL: (514) 856-6928FAX: (514) 856-6886e-mail:*************For immediate technical or application assistance:USA and Canada:Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA®Customer Service: 1-800-622-2378 / 1-800-622-BEST®Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN®TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGAMexico:(001) 800-826-6342FAX: (001) 203-359-7807En Espanol: (001) 203-359-7803e-mail:*******************************.mxServicing Europe:Benelux:Postbus 8034, 1180 LA Amstelveen, The NetherlandsTEL: +31 (0)20 6418405FAX: +31 (0)20 6434643Toll Free in Benelux: 0800 0993344e-mail:************Czech Republic:Rudé armády 1868, 733 01 KarvináTEL: +420 (0)69 6311899FAX: +420 (0)69 6311114Toll Free in Czech Rep.: 0800-1-66342e-mail:***************France:9, rue Denis Papin, 78190 TrappesTel: +33 (0)130 621 400FAX: +33 (0)130 699 120Toll Free in France: 0800-4-06342e-mail:****************Germany/Austria:Daimlerstrasse 26, D-75392 Deckenpfronn, GermanyTel: +49 (0)7056 3017FAX: +49 (0)7056 8540Toll Free in Germany: 0800-TC-OMEGAe-mail:*****************United Kingdom:One Omega Drive, River Bend Technology CentreISO 9002 Certified Northbank, Irlam, ManchesterM44 5EX, United KingdomTel: +44 (0)161 777 6611FAX: +44 (0)161 777 6622Toll Free in the United Kingdom: 0800 488 488e-mail:*************.ukIt is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.MATERIALS OF CONSTRUCTIONHousing Die-Cast ZincSPECIFICATIONSPorts/Mounting Plate 1/4" NPTAdjustment Range -14 to 350 PSI (-1 to 25 bar)Maximum Pressure See Part Number Identification Table Temperature Rating Ambient 14°to 140°F (-10°to 60°C)Media14°to 175°F (-10°to 80°C)Temperature Sensitivity @ Zero PointSet Point Shifts 0.4% of FS/10°C @ Set Point Pressure Set Point Shifts 0.3% of FS/10°C ElectronicsPressure Sensor, Microprocessor Evaluation Circuitry and Solid-state Output DriverSwitching/Reset Point Adjustable between 0 – 100% of FS Linearity< 0.5% of Final Value ±1 digit Electrical ConnectorDIN Style Plug with Removable Cable Plug AdapterFEATURESReal-Time LED Status Display of Pressure Adjustable Hysteresis Off-Line CalibrationFast, Accurate Response Extensive Service LifeAPPLICATIONIdeal for Control of Filtered Compressed Air, Lubricated or Non-LubricatedAll dimensions in inches (mm)PSW31 SeriesELECTRICAL PARAMETERSElectrical connection DIN 43650 Table APower supply (polarity safe)18 to 32V DCPermissible residual ripple10% (within 18 to 32V)Current consumption<50 mA (plus load current)DIN 43650SWITCHING OUTPUTSwitching mode Open collector PNP switched to supply(suited for inductive load)Output voltage Supply voltage minus 1.5V (approx)Contact rating I max= 1A (short-circuit proof)Switching time< 5msService life100 million switching cyclesSwitching logic Signal “on” with rising pressure, if SP* > RP**Signal “on” with falling pressure, if SP < RP* SP = Switching point**RP = Reset pointPART NUMBER IDENTIFICATION*Pressure display in PSIa) Adjusting the switching point.Case 1 or Case 2Press and hold the SP button. The display will show the previous switching pressure setting, and the dotted bar will flash while the button is pressed down (case 1).You can now use the cursor keys to adjust the switching point upwards or downwards. If a cursor key is held down, the values will change faster. When the cursor key is released again, the switch-on pressure setting will cease to change. This setting is stored and activated when the SP button is released, after which the display will show the current pressure value and the bar will quit flashing.b)Adjusting the reset point.Case 3 or Case 4Press and hold the RP button. The display will show the previous reset pressure setting, and the dotted bar will flash while the button is pressed down.You can now use the cursor keys to adjust the reset point in the same manner as described above.During both adjustment operations, it may occur that the hysteresis graph changes from one state to another at the time a transition is made through the point "Switching pressure = Reset pressure".When both points are correctly set, the hysteresis graph will also be correct. You can change between SP and RP as often as you wish until the settings are correct.c) Setting a buffering time.In order to prevent brief pressure “spikes”or “surges” from causing undesiredswitching, a buffering time can be entered.The effect of this is that pressure changes are evaluated only if the pressure signal in question is present for longer than the buffering time. In order to set a buffering time, press the button SP before the powersupply is switched on. Release this button again after the power supply has beenswitched on. The display will then show the buffering time in milliseconds (e.g. 03) or seconds. The cursor buttons w , v can be used to set the buffering time to 03, 06,12, 24 or 50 ms or 0.1, 0.2 or 0.4seconds. When this has been done, press SP to store the setting.d) Setting the pressure switch to ambient pressure = 0.Since ambient pressure varies according to altitude, the user may re-calibrate the zero point to match local conditions.Press the button RP before the power supply is switched on. Release this button again after the power supply has been switched on and the display test has run.The display will then show "OFS". Thecursor buttons w , v can be used to set the pressure display to 0. When this has been done, press SP to store the setting.e) Hysteresis modeIf it is desired to operate with a fixedhysteresis value instead of the reset point,this value can be selected as desired.In order to set a hysteresis value, the two buttons SP and w must be pressed simultaneously before the power supply is switched on.Release these buttons again after thepower supply has been switched on and the display test has run. The display will then show the operating mode. The cursor buttons v ,w can now be used to change the operating mode until "HYS" appears in the display. When this has been done,press SP to store the setting.The SP button can be used to display the switching-point setting, which can be modified by means of the cursor buttons v ,w .The button RP can be used to display the hysteresis setting, which can also be modified by means of the cursor buttons v ,w .Negative hysteresis means: Signal “on”with rising pressure (case 1).Positive hysteresis means: Signal “on” with falling pressure (case 2).If the switching point is modified, this will automatically also result in a change in the reset point by a value equal to the hysteresis setting.Case 2f) Window modeIf it is desired to monitor whether the pressure lies within a certain range, a switching window can be created for this purpose. The pressure switch will then indicate cases in which the actual pressure lies above or below this area.In order to set a switching window, the two buttons SP and w must be pressedsimultaneously before the power supply is switched on.Release these buttons again after the power supply has been switched on and the display test has run. The display will then show the operating mode.The cursor buttons v ,w can now be used to change the operating mode until "FEn"(standing for "Window") in the display. When this has been done, press SP to store the setting. The button SP can be used to display the switching-point setting, which can bemodified by means of the cursor buttons w , v .The distance between the switching point and reset point is the switching window. If theswitching point is lower than the reset point, a signal will be output as long as the pressure lies within the preset window (case 1, rising pressure). If the switching point is higher than the reset point, a signal will be output as long as the pressure lies outside the preset window (case 2, rising pressure). In the case of falling pressure, the signal is inverted.Case 1Std =Standard mode, switching and resetpoints adjustableHYS =Hysteresis mode, switching point andhysteresis adjustableFEn =Window mode, switching windowadjustableA DJUSTING THE S WITCHING P OINTS (SP) AND R ESET P OINTS (RP)Switching Characteristic Graphs Signal “on” with rising pressure Setting SP* > RP**When the switching point (SP) is adjusted HIGHER than the reset point (RP), then the switching output will be “normally off”. When the switching point (SP) is adjusted LOWER than the reset point (RP), then the switching output will be “normally on”.Signal “on” with falling pressure Setting SP < RPSignal “off” with rising pressureSetting RP > SPp RPSPttUSignal “off” with falling pressureSetting RP < SPUPosition of operating elementsE R R O RM E S S A G E SDisplay of hardware errors or malfunctionsWARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling,improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WAR-RANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; mis-application; misuse or other operating conditions outside of OMEGA’s control. Components, which wear, are not warranted, including but not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSO-EVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HERE-BY DISCLAIMED. LIMITATION OF LIABILITY : The remedies of purchaser set forth herein are exclusive,and the total liability of OMEGA with respect to this order, whether based on contract, warranty, neg-ligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, inci-dental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical appli-cations or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS / INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURN-ING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.©Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.FOR WARRANTY RETURNS,please have the following information available BEFORE contacting OMEGA:1.Purchase Order number under which the product was PURCHASED,2.Model and serial number of the product under warranty, and3.Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consultOMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA.1.Purchase Order number to cover the COST of the repair,2.Model and serial number of the product, and3.Repair instructions and/or specific problems relative to the product.Where Do I Find Everything I Need for Process Measurement and Control?OMEGA...Of Course!TEMPERATURE✔Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies ✔Wire: Thermocouple, RTD & Thermistor✔Calibrators & Ice Point References✔Recorders, Controllers & Process Monitors✔Infrared PyrometersPRESSURE, STRAIN AND FORCE✔Transducers & Strain Gages✔Load Cells & Pressure Gages✔Displacement Transducers✔Instrumentation & AccessoriesFLOW/LEVEL✔Rotameters, Gas Mass Flow Meters & Flow Computers✔Air V elocity Indicators✔Turbine/Paddlewheel Systems✔Totalizers & Batch ControllerspH/CONDUCTIVITY✔pH Electrodes, Testers & Accessories✔Benchtop/Laboratory Meters✔Controllers, Calibrators, Simulators & Pumps✔Industrial pH & Conductivity EquipmentDATA ACQUISITION✔Data Acquisition & Engineering Software✔Communications-Based Acquisition Systems✔Plug-in Cards for Apple, IBM & Compatibles✔Datalogging Systems✔Recorders, Printers & PlottersHEATERS✔Heating Cable✔Cartridge & Strip Heaters✔Immersion & Band Heaters✔Flexible Heaters✔Laboratory HeatersENVIRONMENTALMONITORING AND CONTROL✔Metering & Control Instrumentation✔Refractometers✔Pumps & Tubing✔Air, Soil & Water Monitors✔Industrial Water & Wastewater Treatment✔pH, Conductivity & Dissolved Oxygen InstrumentsM-3346/0700。
压力释放阀说明书[中英]
压力释放阀PRESSURE RELEASE VALVE使用说明书OPERATION INSTRUCTION明远电器设备SHENYANG MINGYUAN ELECTRIC EQUIPMENT CO., Ltd.本说明书适用于我公司生产的系列变压器用压力释放阀,阐述其用途、性能、规格、技术参数、使用及安装,供用户参考。
The Operation Instruction is applicable to pressure release valve of a series of transformers manufactured by our company, indicating its application, performances, specifications, technical parameters, usage and installation for uses’ reference.1. 压力释放阀用途和性能压力释放阀适用于油浸式电力变压器、电力电容器及有载分接开关等,用来保护油箱。
当油浸式变压器在运行中出现故障时,由于线圈过热,使一部分变压器油汽化,变压器油箱中压力迅速增加,这时压力释放阀在2ms迅速动作,释放压力,保护油箱不致变形或爆裂。
油箱的压力再升高而达到开启压力时,压力释放阀应再次动作,直到油箱的压力降到正常值。
由于压力释放阀动作后能可靠关闭,油箱外的水和空气不能进入油箱,变压器部不会受大气污染。
1.Application and performancePressure release valves play a vital role in the protection of oil-immersed electrical equipments, such as transformers, high voltage switch gears, capacitor and on load tap-changers, etc. This device can prevent the oil-immersed electrical equipment from deformation or rupture. Should a fault occur in such electrical equipment, from deformation of rupture? Should a fault occurring in such electrical equipment, they are instantaneously vaporize the oil causing extremely rapid build-up of gaseous pressure? If mounting this type pressure release device on the oil-tank, when the pressure reaches to its opening pressure, it opens automatically within 2ms and relieves the pressure.2.型号、规格及基本参数Type, specification and technical parameters2.1 型号的含义 Meaning of typeY S F□—□ / □□□特殊环境代号(Special environment)带机械信号标“J”(“J”:mechanical signal)带信号开关标“K”(“K”:electrical signal)两者都带标“KJ”(“KJ”:Both with signal)喷油有效口径(Caliber of oil-gushing tube)mm开启压力(Opening pressure)kPa设计序号(Design serial number)阀(valve)释放(release)压力(pressure)注:特殊环境代号 note: special environment:TA: 干热带地区 dry tropicTH: 湿热带地区 humid tropicT: 干、湿热带地区 dry、humid tropic例:YSF16-55/130KKJT开启压力为55kPa,喷油口径为φ130mm,带电信号、机械信号。
西门子调节阀VVF31阀体说明书
介质温度低于 0 °C 时,要使用 ASZ6.5 电子阀杆加热元件来防止密封函内的阀杆冻结。 为安全起见,该加热元件的工作电压设计为 AC 24 V,功率为 30 W。
阀门和执行器便于现场组装,无需特殊工具也无需做任何调整。
有
AC 24
SKB60
无 DC 0–10 V 1)
SKB62
有
SKC32.60
无
AC 230
SKC32.61
有 三位
SKC82.60 电动液压
无 120
SKC82.61
有
AC 24
SKC60
无 DC 0–10 V 1)
SKC62有Leabharlann 1) 或 DC 4–20 mA
如需气动执行器,请向西门子楼宇科技的办事处咨询。
30–75% → 等百分比 (ngl = 3) 符合 VDI / VDE 2173
75–100% → 最大流量 kv100 的最优化方案
西门子楼宇科技 暖通空调产品
二通调节阀,法兰连接,PN 10
5/10
AP1N4320zh 2008.11.18
气蚀现象 冷冻水注意事项
气蚀现象会加速阀塞以及阀座的磨损,还会产生不良噪音。如果不超出在第 5 页的流量 曲线图中显示的压差和并遵守如下图所示的静压,气蚀现象可以避免。
3/10
AP1N4320zh 2008.11.18
执行器概览
气动执行器 技术设计 / 机械设计 阀体剖面图
型号
SQX32.00 SQX32.03 SQX82.00 SQX82.03 SQX62
执行器 型号
电动
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
䬬
䔜
绬先㙡遙㆞ 筼┷⨚ 袛梏⨚茫虱欉矊梏 茫肺㇈譻睅秼㽈 ㇢⥭恾☚┪才瘸欓幍⋋㢅 㽈稛筼碟税⚠ℛ儶⥭恾
҈ ⤲
PS10-31⨚ ⦷䳂㊐芚 㽈稛⦷ ⮓⺐桼 ⚛㢅茖幇㽈稛⅝ 税⚠ ㇢ ⮓䤓☚┪才瘸梏䤓欓幍⋋ 梏唾䲊┷ 㽈稛⅝ 税⚠
➥◥
庒唑遙糵ₜ芽礈茽梏⇢ 庒唑犀誑≬㇈譻ₜ芽缗☚⸭ 梏唾✛梏眀䫻德⮓䚕 功䞷
♾折䤓♾折☚┪喒⦃才 EDU SVL
ぴ₩デ屓梏ⷣ
➥
҈ 喝 EDU SVL ≭䛻喝莋屐㊶賍⦍
䘔⇰喝㽈♲ 瘸 ⦷㪖諜☚┪䤓 㢅 蜙⮶ 秧◖ ⒕朮 簌礀
喀⺇ ⒕朮
㠯 喝 EDU SVL ⍕ 㠯 喝 㪖瘮ₐ受蟇厅蓒⺐ 䓳␐喝莋屐
Ϸ䉔喝伧矑⅚ℝ F6W VVX 䤓䪎䓸㽈㒥牑㦘䀵袛⇫䞷䤓⚗㒟㽈 㷱喝蠼㦘腏Ⓟ 莋屐 䬬 喝9& 莋屐
䬬 喝&7 ;; 莋屐 ㏰Т 喝6. ; %% 莋屐
6.520.1
27.6/40034.5/50041.4/600
48.3/70020.7/30013.8/2006.9/100
7.52
流量 (lpm/gpm)压升(p s i /b a r )
流量特点 ② 到 ③
40°C 时 32 cSt/150 ssu 的油液
15.14
22.76
30.38
37.9
10
7.52
流量 (lpm/gpm)
压升(p s i /b a r )
流量特点 ① 到 ②
340°C 时 32 cSt/150 ssu 的油液
15.14
22.76
30.38
37.910
USASI/ISO:
げ
㘩 ⅔㖖㙡ↅ
䃪㒚(bar)†
諽䤌 ♾庒唑㒥㖖⸩☚┪ √Ⱁ M50 EDU M100 EDU
䃪㒚(psi)† 諽䤌 ♾庒唑㒥㖖⸩☚┪ √Ⱁ 9.0 SVL 23.5 SVL
Т ₐ受㳰厅 㪖 N 㺮㳰厅 V
Т喝摜摞 NJ OEV 朱
Ⓟ ぴ⇫槱䫻德⮓䚕 盶缂槱柏枛 蓒⺐ↅ ₐ受蟇厅 2 ⨚皽✛✛貆㺷鉽㖰皽 㪖瘮⨚ 棂㨐㺶荩杬⚗摠㓚㩓✛绬瞹䥥
䬬 喝摜摞 NJ OEV
棂㨐㺶荩舊薦矑杬⚗摠 珩莓 7 欬着⋋才 EDU SVL 莋屐欄 㙟∪䚒犐枇材✛朱Ⓟ梏⧦ ⻉⺇♾賍ₜ⚛ 庆勣籏ぴ☑
䄯㞮䔵Т ⺇␔⏼屡⯃ A 䦃㈓ ⺇ 杬⚗摠㓚㩓 B 折ↅ$ サ婉ヌ䥥 C ぴ☑欓函槭庒唑 F ぴ☑欓函椟塞庒唑 H 折ↅ& サ析兎ⷣ
L
㠯
35 瘸 EDU
瘸 SVL
䬬 ⇥ ⅔帱徼㙡孔ↅ
0 6$( 6T 6$(
8T 喀⺇ %63 2B 喀⺇ %63
3B
%63 梏⧦
8 . Ⓟ抯₢䞷
†
⺕♾庒唑梏欓幍年㇈亶㦏⮶☚┪䤓
6.520.2
䃎䉓
PS10-31__ - __ __ __ - __ - __ __ / __ __ __ __。