CZRB3022中文资料
常熟开关(塑壳断路器)
7
断路器保护特性曲线 PROTECTI ON CHARAC TERISTIC C URVE OF M CCB
8
主要技术性能指标 MAIN TECHNICAL PERFORMANCE INDEX
12
外 形 尺寸 及安 装 尺寸 OUTLINE AND MOUNTING DIMENSIONS
18
断 路 器安 装安 全 间隙 MOUNTING SAFETY CLEARANCE
CMeeratsifuicreatmeeOntf CMoannfaogremmiteynFt oSrystems
公司简介 Introduction
常熟开关制造有限公司是国有资产参股的电器制造企业、“国家重点高新技术企
业”,占地约300亩,员工1500人。主要生产中低压电器元件、工控产品、太阳能光伏 逆变器、成套装置等,可以为您提供“智能配电系统三位一体完整的解决方案”。
塑 料外壳 式断路 器 智能 型塑 壳断路器 带剩 余电流 保护塑壳断 路器 塑料 外壳式断路器 塑料 外壳 式断路器 塑料 外壳式 断路 器 监测型断 路器
CA1系列自动 转换开关Байду номын сангаасCB级)
CA1B系列 小型化自动 转换开关(CB级)
CAP1系列自动 CAP2系列自动 转换开关(PC级) 转换开关 ( PC级)
Post - doctoral scientific research station, Province Enterprise Technique Center and Jiangsu Province Electrical Apparatus Control Engineering Research Center have been established and a multilevel professional technique team has been formed consisting of PHD candidates, postgraduates and university graduates. Engineers and technicians have covered 45% of all staffs.
安科瑞M系列中压保护装置
安科瑞M系列中压保护装置1 概述M系列可编程型微机保护测控装置采用大容量、资源冗余设计,适用于35kV及以下的电压等级电网的保护、控制、测量和监视,可配置为线路、电容器、电动机、进线互投(贯通线备投)等不同回路提供保护功能的数字微机继电保护控制装置。
它可用于不同的主接线方式,如单母线、双母线及多母线接线等方式,也支持不同类型的电网,如中性点不接地系统、经消弧线圈接地系统和小电阻接地系统。
应用行业:广泛应用于电力、化工、国防、建材、市政、学校、医院、建筑、交通、冶金等行业。
2 产品特点●高可靠性设计本产品全部采用工业级元器件,所有与外界的连接都做了充分的电气隔离,内置抗雷击保护电路和电源滤波器。
专业的EMC设计,对装置输入电源、模拟和数字电源进行实时的监测,保证了其运行的可靠性。
●强大的逻辑可编程通过逻辑元件的组合,同一台装置可设计成为实现不同保护功能的综合保护装置。
●灵活方便的接线方式其输入的交流电压可接相电压、线电压、零序电压或是不平衡电压,适应各种PT接线方式。
●高精度的测量和计量保护CT和测量CT分开输入,保证了测量精度和高可靠性要求。
采用频率跟踪技术,实时的检测系统的频率变化,实时的调整数据的采样时间间隔,能保证在基频偏离工频50Hz 很大的情况下准确计算出当时系统的基频分量,谐波分量和零序分量。
●故障录波在每个采样点对所有交流输入量、状态量、开出量和保护模块进行实时的采集并记录。
●保护定值切换可通过面板和通讯方式进行切换,组别切换功能使其快速方便地适应多种运行方式。
●通讯功能以太网通讯规约:Modbus;TCP/IP。
不同的通讯口可设不同的通讯规约,可以同时运行。
●断电保持功能间隙中断条件下,100ms内电源失电,装置不失电。
电源失电50ms后,装置产生失电SOE(事件记录),并保存重要数据。
3 功能配置相瞬时速断电流保护;相限时速断电流保护;相过电流保护;相反时限过流保护;零序定时限一段、二段保护;过电压告警;过电压跳闸;三相一次重合闸;合闸后加速;控制回路断线告警;非电量保护;PT断线告警;负序定时限过流一段;负序定时限过流二段;堵转保护;启动时间过长保护;过热告警保护;过热跳闸保护;零序过压保护;不平衡电压、电流保护;低电压保护;失压重启动保护。
RBS2202系统介绍
关于升版问题: 关于升版问题:CET中有资料 中有资料 下面只介绍操作注意事项: 下面只介绍操作注意事项: 升版分两种;第一种是BSC对DXU的升版,当做完本地操作并 的升版, 升版分两种;第一种是 对 的升版 将检查DXU FLASH中的软件,若版 中的软件, 把DXU置REMOTE,BSC将检查 置 , 将检查 中的软件 本不对将自动升版,不必进行任何BSC操作。基站方面要注意 操作。 本不对将自动升版,不必进行任何 操作 第一点是传输应OK。此时会发现 上红绿灯交替闪、 第一点是传输应 。此时会发现DXU上红绿灯交替闪、红黄灯 上红绿灯交替闪 交替闪、只有绿灯闪。大约20-30分钟升级完成。 分钟升级完成。 交替闪、只有绿灯闪。大约 分钟升级完成 2000基站 基站(macro) 的软件处理: 的软件处理: 基站 (原文件参考 原文件参考CET资料集 资料集/OTHER GUC-ITAC/ABOUT DXU-SW/SW-HANDLING) 原文件参考 资料集 RBS2000的软件包中共有 个软件分别是:(可以用 的软件包中共有6个软件分别是:(可以用 从基站中直接读出) 的软件包中共有 个软件分别是:(可以用OMT从基站中直接读出) 从基站中直接读出 三个装载的应用软件 装载的应用软件: 三个装载的应用软件: LF1 (TRLRxxx), LF2 (ECLRxxx), LF3 (DXLRxxx) 三个基本的应用软件 基本的应用软件: 三个基本的应用软件:LF4 (TRBRxxx), LF5 (ECBRxxx), LF6 (DXBRxxx) 注:TR——TRU、EC——ECU、DX——DXU、L——LOAD、B——BASE、 、 、 、 、 、 R——REVISION、xxx——如082、112、012等版本号。 等版本号。 、 如 、 、 等版本号 当 BTS start-up 或function change时, BSC 检测上述六个软件的版本且有必要时 时 进行升级,(大多数情况下上述三个基本软件是不必更新的,如在正常升版连续4 ,(大多数情况下上述三个基本软件是不必更新的 进行升级,(大多数情况下上述三个基本软件是不必更新的,如在正常升版连续 次失败后自锁,才更新)在每一个MRU单元中都有一个引导软件,这个软件是不 单元中都有一个引导软件, 次失败后自锁,才更新)在每一个 单元中都有一个引导软件 能由BSC进行新级的。当每次进行本地配置(IDB)之后进行的重启动(DXU 进行新级的。 能由 进行新级的 当每次进行本地配置( )之后进行的重启动( RESET),这个引导程序将执行各个硬件单元的测试,也即是说在本地状态下产 ),这个引导程序将执行各个硬件单元的测试 ),这个引导程序将执行各个硬件单元的测试, 生的BS 便是由此而来的。 生的 FAULT便是由此而来的。之后再将应用软件下载至各个单元的 便是由此而来的 之后再将应用软件下载至各个单元的RAM中。 中 所以在DXU的软件更新(DXU上的绿灯闪)约20分钟后,将有一次自动 的软件更新( 上的绿灯闪) 分钟后, 所以在 的软件更新 上的绿灯闪 分钟后 将有一次自动RESET, , 此时各个RU单元的 单元的RAM中才有新的应用软件。 中才有新的应用软件。 此时各个 单元的 中才有新的应用软件
RBS2202讲座
MULTI DROP
MULTI DROP
使用二个PCM,大容量配置 SECTOR 1 SECTOR 2 SECTOR 3 常见配置6+6+6
TEI=62 PCM: CASCADE
RXB OUT1 RXB OUT2
ETCXZSH
CDU-C
DPX/RX OUT
6543
21
输出功率为41.0dbm 每个CELL最多可容纳6个TRU 频率间隔为400KHZ 使用HYBRID COMBINER
ETCXZSH
CDU-C内部结构
TX ANT VSWR LIMIT EXCEED CDU OUTPUT PWR LIMIT EXCEED
ETCXZSH
Radio Building Block 标准配置模块
ETCXZSH
不同配置下的接线方式
注意事项 使用CDU A,C,C+时,每个CDU可接2个TRU.对每个小区而言在确 定TRU位置时注意按照 1 3 2 4的原则. 使用主/副柜的方式时,跨两机柜的小区至少要接2个TRU. CDU C+ 总可以当做CDU C来使用. 注意3DB衰耗器的正确使用 注意Y CABLE的正确使用
OR 2+4
ETCXZSH
CDU C: 3x4
TRU INSERTION SEQUENCE
ETCXZSH
注意
这里指的CDU位置是相对于CELL而言的,不是相对于机柜的 3 1 4 2 1 3 2 4 TRU和CDU之间的RX CABLE连接顺序如图标注,目的是 为了保证分极接收
ETCXZSH
CDU C+:3x2
2. CDU C 除了 1x1 配置时
ETCXZSH
MLW3022-00中文资料
Distinctive CharacteristicsActual SizeIndustry’s first miniature snap-in, lighted rocker switch. Actuators in various styles operate with firm, well-defined movements.Interlocking actuator prevents switch failure due to jamming or window locking.Two bezel sizes adapt to varied panel cutouts. Unique stainless steel retaining clips securely hold switches over a range of panel thicknesses, even when exposed to vibration.Space conserving front panel mounting with minimum behind panel dimension of .902” (22.9mm).Durable stainless steel housing prevents corrosion.Isolated lamp circuit for incandescent, LED, and neon lamps. Front panel relamping.Built-in protective cover shields contacts from dust.Epoxy sealed solder lug terminals lock out flux, dust, and other contaminants.Extended lamp terminal for ease of wiring.Matching indicators available and shown at end of section M.General SpecificationsElectrical CapacityPower Level: 5A @ 125V AC, 3A @ 250V AC, & 3A @ 30V DC;Other RatingsContact Resistance: 10 milliohms maximumInsulation Resistance: 200 megohms minimum @ 500V DCDielectric Strength:1,000V AC minimum between contacts for 1 minute minimum;1,500V AC minimum between contacts & case for 1 minute minimum Mechanical Life: 30,000 operations minimum Electrical Life:10,000 operations minimumNominal Operating Force:9.94N for rockers & 4.41N for paddlesAngle of Throw: 24° for On-None-(On); 28° for all other circuitsMaterials & FinishesHousing:Stainless steel Movable Contacts: Silver alloy Stationary Contacts:SilverBase:Phenolic resinCommon Terminal:Copper with silver plating End Terminals: Copper with silver platingLamp Terminals: Phosphor bronze with nickel platingEnvironmental DataOperating Temperature Range:–10°C through +50°C (+14°F through +122°F) Humidity: 90 ~ 95% humidity for 96 hours @ 40°C (104°F)Vibration:10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning in 1 minute; 3 right angled directions for 2 hoursShock: 50G (490m/s 2) acceleration (tested in 3 right angled directions, with 3 shocks in each direction)InstallationCap Installation Force: 9.80N (2.2 lbf) for rockers;19.61N (4.4 lbf) for paddleSoldering Time & Temperature: Manual Soldering: See Profile A in Supplement section.Standards & CertificationsUL Recognized:All models recognized at 5A @ 125V AC & 3A @ 250V AC; UL File No. WOYR2.E44145Add “/U” to end of part number to order UL mark on switch C-UL Recognized:All models recognized at 5A @ 125V AC & 3A @ 250V AC; C-UL File No. WOYR8.E44145Add “/C-UL” to end of part number to order C-UL mark on switchTYPICAL SWITCH ORDERING EXAMPLECircuitIMPORTANT:Switches are supplied without UL & CSA mark-ings unless specified. Specific models & ratings noted on General Speci- fications page.TERMINALSSwitch Terminals .Lamp TerminalsCenter terminal is .020” (0.5mm) longerThk = (0.8) .031Thk = (0.8) .031LAMP CODES & SPECIFICATIONSElectrical specifications are determined at a basic temperature of 25°C. Lamp circuit is independent of switch operation.For dimension drawings of lamps see Accessories & Hardware section.For neon, if the source voltage is greater than rated voltage, a ballast resistor is required. The ballast resistor calculation and more lamp detail are shown in the Supplement.Incandescent & Neon Lamps for Solid & Design CapsVoltage V 6V AC 12V AC 18V AC 24V AC 28V AC 110V AC Current I80mA 50mA 35mA 25mA 22mA 1.5mA MSCP.159.215.398.215.247NA Endurance Hours 2,000 Average 15,000 Average Ambient Temperature Range–10°C ~ +50°C–10°C ~ +50°CRecommended Resistor for Neon: 33K ohms for 110V AC; 100K ohms for 220V ACNo Lamp Code 00 indicates that no lamp is used.00AT602N NeonT-11⁄2 Pilot Slide Base121806N24AT602Incandescent 28L(+)L(-)LED COLOR CODES & SPECIFICATIONSOPTIONAL BEZELSCAP TYPES & COLORSRA AT405 Rocke rAT438 Design RockerT-13⁄4 Pilot Slide BaseFor Incandescent or Neon LampsRB RC RDRE RF RGPAPB PC PDPE PF PGDB DCDD DFMaterial: Translucent Polycarbonate Standard Finish: GlossyBlack Rocker/Paddle not for use with lamp Opaque Black Rocker BaseLB LC LE LFAT4125 LED RockerSB SCSE SFAT4127 Sculptured RockerMaterial: Translucent Polycarbonate Standard Finish: GlossyColor Codes:BlackWhiteRedOrangeYellowGreenABCDEFBlueG1A AT204 Standard Bezel .787” (20.0mm) Wide1B1C1D1F 1G 1H1E 2A AT9201 Large Bezel .937” (23.8mm) Wide2B2C 2D2F 2G 2H2EDGTranslucent Colored Diffuser Rocker Base.157TYPICAL SWITCH DIMENSIONSWithout BezelSingle & Double PoleActuator in UP position Terminals 4, 5, & 6 are not on single pole modelsMLW3022-12PCStandard Bezel Single & Double PoleActuator in UP position Terminals 4, 5, & 6 are not on single pole modelsMLW3022-12RC-1ALarge BezelSingle & Double PoleActuator in UP position Terminals 4, 5, & 6 are not on single pole modelsMLW3022-12PC-2ASculptured Cap Single & Double PoleActuator in UP position Terminals 4, 5, & 6 are not on single pole modelsMLW3022-CSC-1APANEL CUTOUTS & THICKNESSESWithout Bezel.039” ~ .157” (1.0mm ~ 4.0mm)INSTALLATION & MAINTENANCEWith Standard Bezel AT204.039” ~ .118” (1.0mm ~ 3.0mm)With Large Bezel AT9201.039” ~ .118” (1.0mm ~ 3.0mm)Note: When changing LEDs, match the positive polarity markings on both lamp base and actuator block.LEGENDSGeneral information and basic specifications are presented here for customers who want to do their own legends.Shaded areas are printable areas..030S TO P S T A R TRecommended Print Method:Screen Print or Pad PrintEpoxy based ink is recommendedRockerDesign Rocker Bezel& LED RockerAdditional MethodsAn additional method for legends is engraving the lens. Maximum depth for engraving is.012” (0.3mm) on the cap lens. Enamel paint is recommended to fill the engraved area.Lamps and LEDs can be changed without removing the switch from the panel. The lamps and LEDs.AT107Lamp Extractor。
优利克电力 ETCR3200 双钳接地电阻测试仪 说明书
ETCR3200双钳接地电阻测试仪说明书使用产品之前,请仔细阅读本说明书!武汉优利克电力设备有限公司Wuhan Ulke Power Equipment Co.,Ltd.目录一.简介 (1)二.技术规格 (2)三.仪表结构 (5)四.LCD显示器 (6)五.测量原理 (7)六.操作方法 (10)七.电池更换 (24)八.装箱单 (25)市场上最大口径的精密接地电阻测试仪:φ68mm !抗干扰能力强、重复测试一致性好、精度高!!!一.简介ETCR3200双钳接地电阻测试仪专为现场测量接地电阻、土壤电阻率、接地电压、接地线漏电流、交流电流、直流电阻而精心设计制造的,采用最新数字处理技术,精密4线法、3线法和简易2线法、选择法、双钳法测量接地电阻,大口径电流钳设计,可测量使用大型接地引下线的接地系统,可灵活准确测量单点和网状接地等各种复杂接地情况的任意接地电阻值,并联接地测量时而无需断开任何并联接地电极,最大程度地提高测量的方便性。
导入FFT(快速傅立叶变换)技术、AFC(自动频率控制)技术,具有独特的抗干扰能力和环境适应能力,重复测试一致强,确保长年测量的高精度、高稳定性和高可靠性。
其广泛应用于电力、电信、气象、油田、建筑、防雷及工业电气设备等的接地电阻、土壤电阻率、接地电压、交流电流漏电流测量。
ETCR3200双钳接地电阻测试仪由主机、电流钳、监控软件、测试线、辅助接地棒、通讯线等组成。
主机超大LCD 显示,蓝屏背光,棒图指示,一目了然。
同时能存储100组数据,通过监控软件实现历史查询与在线实时监测功能,动态显示,告警指示,自动关机,具有历史数据读取、查阅、保存、报表、打印等功能。
二.技术规格1.基准条件和工作条件影响量基准条件工作条件备注环境温度23℃±1℃-10℃~40℃----环境湿渡40%~60%<80%----仪表工作电压9V±0.1V9V±1.5V----辅助接地电阻值<100Ω<30kΩrC、rP 干扰电压无<20V----干扰电流无<2A----测R时电极间距a>5d a>5d----测ρ时电极间距a>20h a>20h----2.一般规格功能二三四线法、选择法、双钳法测量接地电阻、土壤电阻率;接地电压、交流电压测量、交流电流漏电流测量电源DC9V(锌锰干电池R14S 1.5V6节,连续待机300小时)电流钳口径φ68mm量程选择法测量:0.00Ω~3000Ω双钳法测量:0.01Ω-100Ω二三四线法测量:0.00Ω~30.00kΩ土壤电阻率:0.00Ωm~9000kΩm直流电阻:0.00Ω~30.00kΩ接地电压:0.0V~100.0V交流电流:0.0mA~600A测量方式精密4线、3线法测量、简易2线、选择法、双钳法测量接地电阻测量方法二三四线法测量:变极法,测量电流20mA Max选择法测量:变极法,测量电流20mA Max双钳法测量:非接触互感测量法,测试电流1mA Max 土壤电阻率:四极法(温纳法)对地电压:平均值整流(P(S)-ES接口间)交流电流:钳形电流互感器测量测试频率128Hz/111Hz/105Hz/94Hz(AFC)短路测试电流AC20mA max开路测试电压AC40V max测试电压波形正弦波适合安规IEC61010-1(CATⅢ300V、CAT IV150V、污染度2);IEC61010-031;IEC61557-1(接地电阻);IEC61557-5(土壤电阻率);JJG366-2004。
火灾报警联动控制系统产品手册
尊敬的用户:西安西核彩桥实业科技有限公司地处西安市高新技术开发区,是专业生产火灾报警联动控制系统的高新技术企业,是中美合资西安盛赛尔电子有限公司(systemsensor)的紧密型合作伙伴。
公司自主研发的CH8000系列智能火灾报警控制系统,全面采用美国盛赛尔公司(systemsensor)的设计理念、先进技术、通讯协议、制造工艺,与国际火警行业的先进技术同步,该系统全面兼容盛赛尔公司生产的智能型、常规型、特殊型产品,具有工作稳定、扩展性强、容量大、网络化等特点。
公司拥有优秀的团队、先进的设备、超前的理念,遍及全国的销售服务网络,产品广泛应用于石油、化工、电信、移动、钢铁等国家重点行业和大型楼宇场馆,以可靠的产品,优质的服务,诚信的文化赢得用户的满意。
公司将和全体销售服务商一起为用户竭诚服务,以我卓越科技,护航您美好未来。
目录1、JTY-LZ-ZM991智能离子感烟火灾探测器2、JTY-GD-ZM992智能光电感烟火灾探测器3、JTW-BD-ZM995智能感温火灾探测器4、JTY-GD-882光电感烟火灾探测器5、JTW-BD-885感温火灾探测器6、JTYJ-GD-2630/B 独立式感烟火灾探测报警器7、JTYJ-GD-2690/B 独立式感烟火灾探测报警器8、BAEM1224S型红外光束感烟火灾探测器9、AEC2361a 可燃气体探测报警器10、AEC2371a 可燃气体探测报警器11、J-SAP-M-SB8304 编址手动火灾报警按钮12、J-SAP-M-SB8304/H 编址消火栓报警按钮13、SM8301 输入模块14、KM8302 输入/输出模块15、KM8302B 切换模块16、DB8307 总线短路保护器17、M902M 探测器接口模块18、SG8306A 编址声光警报器19、ZH8310A 现场转换盒20、SSM24-6 警铃21、SG8306 声光警报器22、CH8504 放气指示灯23、CH8505 紧急启停按钮24、CH8507 手/自动转换盒25、CH8316/20/48/72 路接线端子箱26、CH8907/6/12/20模块箱27、FS-100 火灾显示盘28、CH8605 多线联动控制盘29、CH8601 总线手动控制盘30、JB-QB-CH8000 火灾报警控制器(联动型)31、JB-QB-CH8800 火灾报警控制器(联动型)32、JB-QB-CH8000/S 火灾报警控制器33、JB-MH-CH8500 气体灭火控制器34、JB-QB-CH8800 气体灭火控制器35、CH8909 CRT火灾彩色平面图形显示系统36、GB9242 消防广播主机37、DH9251 多线火警电话主机38、DH9261 总线制火警电话主机39、CH9200 壁挂广播通讯柜1、JTY-LZ-ZM991智能离子感烟火灾探测器功能描述及技术指标◆适用于发生火灾后产生大量的烟和少量热的场所,如宾馆、饭店、办公楼、机房、医院、学校等各种室内场所。
功率隔离变送器
使用说明书
中捷联创(香港)股份有限公司 深圳市中捷联创电子技术有限公司
产品应用
IPA 系列功率隔离放大器是将工业自控系统中 标准的模拟直流电压、电流信号或者 PLC 标准信号 输入,经隔离后转换成可带动功率负荷的需要.广泛缓 冲或者流量、压力等控制.
产品特点
该产品采用磁电隔离技术,输入输出信号、供 电电源之间相互隔离,隔离强度达 2500V/DC,并且温 度漂移小、工作温度范围宽、线性度高、免调式等 特点.
产品引脚定义
产品选型指南
IPA-A-B-C-D-E
安装方式(DIN35) 驱动电流(OC) 供电电压(PV) 输出信号(OV) 输入信号(INS) 产品系列
产品举例说明
产品尺寸
例 1:输入信号 0-10V,输出信号 0-10V,供电电压 24V,驱 动电流 200mA 型号:IPA665A2G
深圳市中捷联创电子技术有限公司
-
- 100mA A1
3
-
-
-
- 12V 3 200mA A2
4
-
-
-
- 15V 4 500mA A5
G
5 0 -5 V 5 0 -5 V 5 2 4V 5 1000 m A A A
6 0- 10 V 6 0- 10 V 6
7 自定义 U 自定义 U 自定义 U 自定义 U
产Байду номын сангаас特性
* 高精度............................................................0.1% * 高线性度........................................................0.1% * 低温漂...........................................................35PPM * 保 护.......................................................输出短路 * 隔离电压..................................................2500V/DC * 工业级........................................-25~71℃工作温度 * 标准导轨安装.
Omega 技术有限公司产品说明书:可编程隔离潜力传感器传输器 TX802系列
An OMEGA Technologies CompanyU s e r 's G u i d ee-mail:**************TX802P SERIESPROGRAMMABLE ISOLATINGPOTENTIOMETER TRANSMITTERWhere Do I .ind Everything I Need for Process Measurement and Control?OMEGA...Of Course!TEMPERATUREThermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point ReferencesRecorders, Controllers & Process Monitors Infrared PyrometersPRESSURE, STRAIN AND .ORCE Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories.LOW/LEVELRotameters, Gas Mass Flowmeters & Flow Computers Air Velocity IndicatorsTurbine / Paddlesheel Systems Totalizers & Batch ControllerspH/CONDUCTIVITYpH Electrodes, Testers & Accessories Benchtop/Laboratory MetersControllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment DATA ACQUISITIONData Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging SystemsRecorders, Printers & Plotters HEATERS Heating CableCartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory HeatersENVIRONMENTALMONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & TubingAir, Soil & Water MonitorsIndustrial Water & Wastewater TreatmentpH, Conductivity & Dissolved Oxygen InstrumentsM-3786/0302✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔✔OMEGAOMEGAnet SM On-Line Service Internet e-mail **************Servicing North America:USA:One Omega Drive, Box 4047ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec) H7L 5A1Tel: (514) 856-6928FAX: (514) 856-6886e-mail:****************.or immediate technical or application assistance: USA and Canada:Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SMCustomer Service: 1-800-622-2378 / 1-800-622-BEST SMEngineering Service: 1-800-872-9436 / 1-800-USA-WHEN SMTELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico andLatin America:Tel: (95) 800-TC-OMEGA SM FAX: (95) 203-359-7807En Espanol: (203) 359-7803e-mail:*****************Servicing Europe:Benelux:Postbus 8034, 1180 LA Amstelveen, The NetherlandsTel: (31) 20 6418405FAX: (31) 20 6434643Toll Free in Benelux: 06 0993344e-mail:************Czech Republic:ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech RepublicTel: 420 (69) 6311627FAX: 420 (69) 6311114e-mail:***************France:9, rue Denis Papin, 78190 TrappesTel: (33) 130-621-400FAX: (33) 130-699-120Toll Free in France: 0800-4-06342e-mail:****************Germany/Austria:Daimlerstrasse 26, D-75392 Deckenpfronn, GermanyTel: 49 (07056) 3017FAX: 49 (07056) 8540Toll Free in Germany: 0130 11 21 66e-mail:*****************United Kingdom:25 Swannington Road,P.O. Box 7, Omega Drive,ISO 9001 Certified Broughton Astley, Leicestershire,Irlam, Manchester,LE9 6TU, England M44 5EX, EnglandTel: 44 (1455) 285520Tel: 44 (161) 777-6611FAX: 44 (1455) 283912FAX: 44 (161) 777-6622Toll Free in England: 0800-488-488e-mail:************It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, patient connected applications.OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unau-thorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibra-tion; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s con-trol. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESEN-TATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS-CLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whetherbased on contract, warranty, negliegence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO A VOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent break-age in transit.FOR WARRANTY RETURNS, please have thefollowing information available BEFORE contact-ing OMEGA:1. P.O. number under which the product was PURCHASED,2. Model and serial number of the product underwarranty, and3. Repair instructions and/or specific problemsrelative to the product.FOR NON-WARRANTY REPAIRS, consultOMEGA for current repair charges. Have thefollowing information available BEFORE contacting OMEGA:1. P.O. number to cover the COST of the repair,2. Model and serial number of product, and3. Repair instructions and/or specific problemsrelative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.The Proper Installation & Maintenance of TX802P.MOUNTING.(1)Mount in a clean environment in an electrical cabinet on DIN or EN mounting rail.(2)Do not subject to vibration or excess temperature or humidity variations.(3)Avoid mounting in cabinets with power control equipment.(4)To maintain compliance with the EMC Directives the TX802P is to be mounted in a fully enclosed steel cabinet.The cabinet must be properly earthed, with appropriate input / output entry points, filtering and cabling. WIRING.(1)All cables should be good quality overall screened INSTRUMENTATION CABLE with the screen earthed at oneend only.(2)Signal cables should be laid a minimum distance of 300mm from any power cables.(3)For 2 wire current loops and 2 wire voltage signals or 2 wire current signals, Austral Standard Cables B5102ESis recommended. For 3 wire transmitters, RTDs, resistance probes, and potentiomaters Austral Standard Cables B5103ES is recommended.(4)It is recommended that you do not ground current loops and use power supplies with ungrounded outputs.(5)Lightning arrestors should be used when there is a danger from this source.(6)Refer to diagrams for connection information.COMMISSIONING.(1)Once all the above conditions have been carried out and the wiring checked apply power to the TX802P loop andallow five minutes for it to stabilize.(2)Due to cable resistance and errors within the potentiometer itself a small error may occur (usually less than1%).To remove this error adjust the Zero and Span trimpots in the top of the TX802P enclosure with a small screwdriver.(Clockwise to increase the output reading & Anticlockwise to decrease the output reading)(3)Take a low (approx 10%) and high (approx 90%) reading of the variable being measured by the transducersupplying the signal to the LPI-P, and ensure that this agrees with the level being indicated by the PLC or indicator, etc, that the TX802P is connected into. Adjust for any difference using the Zero and Span trimpots in the top of the TX802P enclosure.MAINTENANCE.(1)Repeat (3) of Commissioning.(2)Do it regularly - at least once every 12 months.TX802P PotentiometerTransmitter.Isolating 3 Wire PotentiometerInput to 4~20mA OutputLoop Powered Transmitter.Features.l Field Programmable Input Ranges.l Isolated Input to Output 2.0kV.l High Accuracy.l40~200mV Output Test Signal.l LED Indication of Loop Current.l Low Cost.l Easy to Install.l Compact DIN Rail Mount Enclosure.l Available Standard or Special Calibration.l Reverse Polarity Protection.l Corrosion Proofed Circuit Board & Componentsby Isonel 642. (Except Terminals & DIP Switches.)Graph Of Maximum Load Enclosure Dimensions.Versus Power Supply.MaximumLoad(Ω)Power Supply (Vdc)Quality Assurance Programme.The modern technology and strict procedures of the ISO9001 Quality Assurance Programme applied during design, development, production and final inspection grant the long term reliability of the instrument.TX802P Specifications.Potentiometer Input3 Wire Potentiometer.Excitation = 0.25V.Minimum Potentiometer Resistance = 1k Ω.Maximum Potentiometer Resistance = 1M Ω.Field Programmable Zero From 0 to 100%.Field Programmable Span From 0 to 100%.Output- mA 2 Wire 4~20mA. (Loop Powered.)- mV40~200mV ∝ 4~20mA. (Indicative Test Signal Only.)Other Output Voltages Available. eg 1~5V.Power Supply8~40Vdc.Supply Voltage Sensitivity <±0.005%/V FSO.Output Load Resistance 800Ω @ 24Vdc. (50Ω/V Above 8Vdc.)Maximum Output Current Limited to <28mA.Accurate to<±0.1% FSO Typical.Linearity & Repeatability <±0.1% FSO Typical.Ambient Drift <±0.02%/C FSO Typical.Noise Immunity 125dB CMRR Average. (2.0KVac RMS Limit.)R.F. Immunity <1% Effect FSO Typical.Isolation Voltage 2.0kVac/dc Input to Output for 60sec.Response Time200msec Typical. (10 to 90% 50msec Typical.)Operating Temperature 0~70C.Storage Temperature -20~80C.Operating Humidity 90%RH Max. Non-Condensing.Construction6.6 Polyamide Thermoplastic Rail Mount Enclosure.Note 1.Specifications based on Standard Calibration Unit, unless otherwise specified.Note 2.Due to ongoing research and development, designs, specifications, and documentation are subject to change without notification.No liability will be accepted for errors, omissions or amendments to this specification.Plan View of TX802P Adjustments.Power Supply TerminalsExamples of Input Connection.Terminations.Input1HIGH 2COM 3WIPER Output4+mA 5-mA6mV TESTTX802P Input Programming.If the input range is not listed in the programming table, use the following formulae to work out the Zero and Span DIP switch settings for gain.Span Gain =600 .POT% High - POT% LowZero Gain = POT% Low2Enter the Zero or Span gain value into the appropriate Zero or Span DIP switch.TX802P Input Range Programming Table.Notes:1/ Switch status 1 = ON, 0 = OFF, X = DON'T CARE.2/ Input ranges with '*' beside them require more adjustment by the Zero & Span trimpots.So if a gain value of 28 is required, put DIP switch No's 3, 4, 5 OFF (ie, gains of 4 + 8 + 16 = 28) and all the other DIP switches ON.Dip switches are accessed by seperating the two halves of the TX801P / TX802P enclosure。
fc302说明书
f c302说明书篇一:M SC302-说明书 MS C302配电隔离器功能向现场2/3线制变送器提供工作电源,同时采样变送器的输出电流,经过隔离转换后,输出到D CS或PLC。
也可用于4线制变送器,隔离变送器输出的电流信号。
型号规格及代码技术指标工作电源:24VD C±10% 功耗:≤2.5W配电电压:18.5~28.5V配电保护:最大短路电流,30m A输入阻抗:电流采样等效电阻≤100Ω输出负载:电流输出,≤350Ω电压输出,≥5kΩ 转换精度:±0.2%F.S温度漂移:±0.015% F.S/℃安装方法35m m导轨卡装;主机与底座可以插拔分离绝缘强度:输入/输出,≥2017VAC(1min)输入/电源,≥2017VAC(1m in)输出/电源,≥1000V AC(1min)绝缘电阻:输入/输出/电源,≥100MΩ(500VDC)工作条件工作温度:0~50℃存储温度:-40~85℃相对湿度:10~90%RH大气压力:86~106kPa外形尺寸图120mm*95mm*23m m篇二: Dan foss FC302变频器的使用Danf os sFC 300变频器使用1.初始化:14-22: 2 初始化变频器断电再次上电时参数初始化到默认值0—01: 10语言选择为中文。
江苏思源互感器有限公司——思源电气
思源电 气75%
香港赫 兹25%
江苏思源赫兹互感器有限公司 成立于2004年8月,是由思源 电气股份有限公司与香港赫兹 有限公司双方合作,投资一亿 元人民币兴建的专业研发、生 产高压电流、电压互感器的高
1
新技2 术企业。 3
Sieyuan Electric
Copyright © Sieyuan Electric Co., Ltd. All Rights Reserved.
15
电压互感器种类
35~110kV油浸电磁式电压互感器
Sieyuan Electric
Copyright © Sieyuan Electric Co., Ltd. All Rights Reserved.
16
电压互感器种类
35~220kV SF6气体绝缘电压互感 器
Sieyuan Electric
铁心 屏蔽 罩壳二次引线通过中间铝管引到产品
底部的出线盒里,铝管能够承
载短路电流,一旦头部发生故
障时,能将短路电流接地,避
二次引 线管
免套管部分发生爆炸。
Sieyuan Electric
Copyright © Sieyuan Electric Co., Ltd. All Rights Reserved.
31
C、产品的竞争优势
1 绝缘性能优异:电容屏套管采用整张进口高强度电缆纸绕制,工艺分散性小。80 %工频耐压值下局放小于5pC(国内外还没有厂家提出在80%工频耐压值下测局 放)。整体真空干燥注油工艺,避免二次受潮。介损稳定不回升。
2 全密封结构:全密封结构,德国进口 焊接机器人焊接代替传统的手工焊接, 提高焊接工艺,保证产品不漏油,免 维护。
Sieyuan Electric
NRCS-3022主变高后备保护
NRCS-3022变压器高后备保护测控单元使用说明书一、概述适用范围NRCS-3022变压器高后备保护装置是用于110kV及以下电压等级的双圈、三圈变压器的成套装置,可集中组屏,也可在开关柜就地安装,全面支持变配电综合自动化系统。
功能及特点1.NRCS-3022变压器后备保护单元主要功能◆二段式复合电压闭锁方向过流保护(限时速断,过流)◆三段式零序电压闭锁方向零序过流保护◆过负荷告警◆间隙零序◆零序过电压◆过负荷启动通风2.辅助功能◆PT断线、PT失压告警◆母线接地告警◆控制回路断线告警◆装置故障告警◆故障录波◆保护定值和时限的独立整定◆自检和自诊断3.测控功能◆电量测量(遥测量):电压、电流、有功功率、无功功率、有功电能、无功电能、功率因数、电网频率等◆遥信量:装置共有14路开入量,其中:12路为采集外部遥信,2路为内部开关量信号◆遥控量:完成1台断路器就地或遥控分合闸操作4.闭锁功能◆断路器就地和遥控操作互为闭锁且具有防跳功能5.通讯功能◆CAN总线,以及标准的RS485多机通讯接口6.特点◆采用分层分布式设计,可组屏安装或直接安装于开关柜上◆封闭、加强型单元机箱,抗强干扰设计,适用于恶劣环境,可靠性高、抗干扰能力强,符合IEC电磁兼容标准◆可以实现远方定值整定与修改◆事件顺序记录并上传SOE事件◆汉字液晶显示,键盘操作◆设有独立的起动元件用来开放继电器电源,提高装置的安全性一、 基本原理复合电压闭锁过流保护本装置设二段复合电压启动过流保护,各段过流定值及时间定值可独立整定。
可通过保护投退选择低电压或负序电压启动过流保护。
另外,当PT 断线信号和PT 失压信号出现时自动退出低电压或负序电压的闭锁。
这两段保护均带方向闭锁,由保护投退选择,方向元件最大灵敏角为45度。
&&≥1>dz2跳变压器各侧开关(1、3、5、6)tzd2RLP1≥1tzd1>dz2>dz2>dz1>dz1≥1RLP1>dz1RLP12RLP11RLP4RLP3低电压<负序电压>断线信号失压信号复合电压启动过流段跳母联开关(5)复合电压启动过流段方向元件两段过流保护均有方向元件,并可投退。
施耐德 XALB02C 按钮盒 2孔 数据表
Product data sheetCharacteristicsXALB02C按钮盒(2孔)主要信息产品系列Easy Harmony XALB 产品类型空机柜产品短名XALB 产品适用于XB2 non-illuminated functions with 1 row contact block开孔数2 开孔机柜基座颜色深灰封面颜色浅灰材料PC IP 保护等级"IP65" 符合 IEC 60529补充信息电缆进线孔 2.0 敲落孔 直径: 20 mm 在…上 侧面 4.0 敲落孔 直径: 19 mm 在…上 bottomCAD 总宽度68 Mm CAD 总高度51 Mm CAD 总深度104 Mm 净重0.12 Kg 环境贮存环境温度-40…70 °C运行温度-25…70 °C 电击保护级别Class II 符合 IEC 60536符合标准GB/T 14048.5 GB/T 14048.1 IEC 60947-5-1 IEC 60947-1 IEC 60947-5-4包装单位Unit Type of Package 1PCENumber of Units in Package 11Package 1 Height5.5 CmPackage 1 Width7.195 CmPackage 1 Length10.693 CmPackage 1 Weight120.0 GUnit Type of Package 2S02Number of Units in Package 225T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .Package 2 Height15.0 CmPackage 2 Width30.0 CmPackage 2 Length40.0 CmPackage 2 Weight 3.651 KgUnit Type of Package 3PALNumber of Units in Package 3500Package 3 Height60.0 CmPackage 3 Width80.0 CmPackage 3 Length90.0 CmPackage 3 Weight73.443 Kg可持续性产品类型Green Premium 产品REACh法规REACh 声明REACh free of SVHC支持欧盟ROHS指令主动合规性(超出欧盟 RoHS 法定范围的产品)欧盟ROHS声明Toxic heavy metal free支持Mercury free支持RoHS exemption information支持中国 ROHS 管理办法中国 ROHS 声明环境披露产品环境文件流通资料产品使用寿命终期信息合同保修保修单18 个月Product Life Status :Commercialised。
安贝特自动保护装置说明书
2、检查电源、电缆、控制盒是否松动或断开,如有问题及时处理。
3、将油压开关固定安装在柴油机供油管道上,防爆控制盒装在驾驶台上让司机便于观察,
测排气温度和冷却水温度的传感器分别置于柴油机排气口处和冷却水箱中,温度开关置于柴
油机最高表面温度处,油压开关接在柴油机机油管路上,转速传感器安装在柴油机皮带轮或
飞轮处,水位传感器置于废气处理箱底部。所有导线用导管固定或安装于机车凹下地方,以
防损坏和碰断。
4、检查执行电路与防爆控制盒完好后,自动保护装置方可通电工作。
5、时间延时在出厂已经整定好,用户无须自行调节。
6、常见故障处理
A、线导头不吸合:一般是电磁头与电控箱损坏或元件失效所致。调整电磁头或电控箱;如
-2-
PDF 文件使用 "pdfFactory Pro" 试用版本创建
DC.24V
DC/DC
变换单元 DC.7V
控制箱 (IC 控制模块)
执行单元
温度传感器 温度传感器
温度开关
水位传感器 油压开关ቤተ መጻሕፍቲ ባይዱ转速传感器
单位名称:苏州安贝特防爆设备有限公司 单位地址:苏州吴中区横泾街道上新路 8 号 联系电话:0512-66524160 传 真:0512-66524060
-3-
PDF 文件使用 "pdfFactory Pro" 试用版本创建
附录: 装置组成:
名称 防爆柴油机车用隔爆兼本质 安全型自动保护装置主机 矿用本质安全型转速传感器 矿用温度传感器 矿用温度传感器 防爆柴油机用油压开关 矿用本质安全型温度开关 矿用本质安全型水位传感器
不能解决,可更换。
B、探测传感器或探测开关无信号输出,一般是控制模块 IC、探测传感器或探测开关失效所
通信主设备基本知识
通信主设备基本知识1、RBS2000系列基站设备的具体分类爱立信基站重要类型:RBS2202系列、RBS2206系列、微峰窝系列、室外站系列。
RBS2101~RBS2103系列这种设备属于室外安装类型的设备,那个类型的基站设备重要为室外的情形应用而设计的,除了主设备以外,还有空调,温度操纵,供电等从属设备,平日采取自力供电进行工作,能够防雨水、防霜冻等。
但受外界干扰较大年夜,晦气收集的稳固。
在我国GSM运营商几乎不应用该系列的机型。
RBS2202系列这种类型的设备属于室内安装的设备,构造较RBS2100系列的设备简单,没有自力的外部情形体系,弗成自力供电(但能够自带整流模块)等,必须在室内安装应用。
这种系列是我国GSM运营商所采取的重要Ericsson设备类型。
RBS2301、RBS2302、RBS2402、MAXITE系列这种类型的设备属微蜂窝设备,能够在室内和户外安装,能够自力供电应用,体积较小,安装灵活便利。
重要用在街道覆盖、室内覆盖等。
RBS2206系列这种类型的设备属于室内安装的设备。
RBS2206 是一种室内型宏蜂窝基站设备,每个机柜可支撑最多12 个收发信机。
其机柜与RBS2202 占地面积雷同,略高,因为采取新型两倍容量的收发信机和合路器,机柜的载波容量也是RBS2202 的两倍。
其“双收发信机”—dTRU—与今朝的单个TRU 体积雷同,却在一个单位里包含有两个收发信机2、RBS2000系列基站构成:下图是RBS2000在收集中的地位及构造:●移动台(MS):移动用户应用的便携终端。
由收发信机、天线、人机介面、电池等构成;●基站(BS):基站收发信机、操纵设备、天馈体系等构成,供给MS与BSC●基站操纵器(BSC):为MSC接口,治理BS。
移动交换中间(MSC):收集的核心,供给交换、收集操纵与治理、互连接口等功能。
基站治理操纵关系简化图:(1)重要硬件构成RBS2202机柜外型:RBS2206机柜图:BSCDXU TRUTRUA-BISLOCAL--BUSRBS2000●DXU (Distribution switch Unit)分派交换单位。
RBS2202硬件介绍和硬件连接
2、timing bus(定时总线):从DXU单元至TRU、ECU单元间传送 无线空间的发射频率所需的始终信息; 3、X总线:在各个TRU单元间以一个时隙为基础传送话音/数据信息 ,用于基带跳频; 4、CDU总线:连接CDU单元至各个TRU单元,在CDU和TRU之间 传送告警和RU单元的特殊信息,帮助实现O&M功能; 5、电源通信环路:在ECU、PSU和BFU之间传送控制和管理信息。
2006-3-8
课前提问
1. 爱立信公司开发的产品中支持GSM标准的系统产品是什 么? CME20-GSM900和DCS1800;CMS40-PCS1900 2. BSC中区别于其他交换机的特殊硬件是什么? TRAU和TRH 3. TRAU的作用是什么? 语音重新编码,数据速率转换 4. TRH的作用是什么? 管理BSC与BTS之间信令(LAPD协议)
Open
28
RBS 2206 O&M
2006-3-8
定时总线(Timing Bus)
GS
ETC
本地总线(Local Bus)
ETC
TRAU TRH RPD RP RP
本地终端 接口 A-BIS 接口 DXU
TRU CDU
天馈线接口
测试MS接口 外部告警 接口
X-Bus 天馈线接口
TRU CDU CDU BUS
爱立信数字基站的操作与维护爱立信数字基站的操作与维护openrbs2206om2006381内容安排内容安排??cme20cme20基础理论rbs2202基站系统概述基站系统概述202硬件介绍硬件介绍202硬件连接硬件连接??rbs2rbs2202202硬件连接硬件连接000软件结构软件结构202操作维护操作维护22066介绍介绍基础理论??rbs2202??rbs2rbs2202??rbs2rbs2202openrbs2206om2006382??rbs2rbs2000??rbs2rbs2202??rbsrbs220课前提问1
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Voltage: 11 - 100 V olts Power: 3.0 WattCZRB3011Thru CZRB3100Features- For surf ace mounted applications in order to optimize board space - Low profile package - Built-in strain relief- Glass passivated junction - Low inductance- Excellent clamping capability- Typical I less than 1uA above 11V D - High temperature soldering 260°C /10seconds at terminals- Plastic package has underwriters laboratory flammability classification 94V-OMechanical data- Case: JEDEC DO-214AA,Molded plastic over passivated junction- Terminals: Solder plated, solderable per MIL-STD-750, method 2026- Polarity: Color band denotes positive end (cathode) except Bidirectional-Standard Packaging: 12mm tape (EIA-481) -Weight: 0.002 ounce, 0.064 gramMaximum Ratings and Electrical CharactericsRatings at 25°C ambient temperature unless otherwise specified.I ZKV R(Volts)(mA)(Ohms)(Ohms)(mA)(uA)(Volts)MadcIr - mACZRB3011116847000.2518.4225 1.82CZRB30121263 4.57000.2519.1246 1.66CZRB30131358 4.57000.250.59.9208 1.54CZRB3014145357000.250.510.6193 1.43CZRB30151550 5.57000.250.511.4180 1.33CZRB30161647 5.57000.250.512.2169 1.25CZRB3017174467500.250.513150 1.18CZRB3018184267500.250.513.7159 1.11CZRB3019194077500.250.514.4142 1.05CZRB3020203777500.250.515.2135 1.00CZRB3022223487500.250.516.71230.91CZRB3024243197500.250.518.21120.83CZRB30272728107500.250.520.61000.74CZRB30282827127500.250.521960.71CZRB303030251610000.250.522.5900.67CZRB303333232010000.250.525.1820.61CZRB303636212210000.250.527.4750.56CZRB303939192810000.250.529.7690.51CZRB304343173315000.250.532.7630.45CZRB304747163815000.250.535.6570.42CZRB305151154515000.250.538.8530.39CZRB305656135020000.250.542.6480.36CZRB306262125520000.250.547.1440.32CZRB306868117020000.250.551.7400.29CZRB307575108520000.250.556360.27CZRB3082829.19530000.250.562.2330.24CZRB3091918.211530000.250.569.2300.22CZRB31001007.516030000.250.576270.20NOTE:MaximumZenerCurrent I ZM1. Tolerance and Type Number Designation. The type numbers listed have a standard tolerance on the nominal zener voltage of ±5%.2. ZENER VOLTAGE (Vz) MEASUREMENT - guarantees the zener voltage when measured at 40 ms +- 10ms from the diode body, and an ambient temperature of 25 °C (+8°C , -2°C ).3.ZENER IMPEDANCE (Zz) DERIVATION - The zener impedance is derived from the 60 cycle ac voltage, which results when an ac current having an rms falue equal to 10% of the dc zener current (I ZT or I ZK ) is superimposed on I ZT or I ZK .4. SURGE CURRENT (Ir) NON-REPETITIVE - The rating listed in the electrical characteristics table is maximum peak, non-repetitive, reverse surge current of 1/2 square wave or equivalent sine wave pulse of 1/120 second duration superimposed on the test current, I ZT , per JEDEC standards, however, actual device capability is as described in Figure 3.ELECTRICAL CHARACTERISTICS(T A =25°C unless otherwise noted) (V F =1.2Volts Max, I F =500mA for all types.)Device (Note 1.)Nominal ZenerVoltage V Z @ I ZT(Note 2.)Test current I ZTMaximum Zener Impedance(Note 3.)Leakage Current SurgeCurrent@T A =25°C(Note 4.)Z ZT @ I ZT Z ZK @ I ZKI RRating and Characteristic Curves (CZRB3011Thru CZRB3100)Fig.2-TYPICAL THERMAL RESPONSE L,P.W.PULSE WIDTH (ms)0.10.050.030.020.010.0050.0030.0020.0010.00050.00030.00020.0001NOMINAL VZ (VOLTS)Fig.3-MAXIMUM SURGE POWERFig.4-TYPICAL REVERSE LEAKAGEVZ,ZENER VOLTAGE @IZT (VOLTS)VZ,ZENER VOLTAGE @IZT (VOLTS)Fig.5-UNITS TO 12VOLTS Fig.6-UNITS 10TO 100VOLTSRating and Characteristic Curves (CZRB3011 Thru CZRB3100)VZ,ZENER VOLTAGE (VOLTS)VZ,ZENER VOLTAGE (VOLTS)L,LEAD LENGTH TO HEAT SINK(INCH)TYPICAL THERMAL RESISTANCEAPPLICATION NOTE:Since the actual voltage available from a given zener diode is temperature dependent, it is necessary to determine junction temperature under any set of operating conditions in order to calculate its value. The following procedure is recommended:Lead Temperature, T L, should be determined from:T L = șLA P D + T AșLA is the lead-to-ambient thermal resistance (°C/W)and PD is the power dissipation. The value forșLA willvary and depends on the device mounting method.șLA is generally 30-40 °C/W for the various chips andtie points in common use and for printed circuit boardwiring.The temperature of the lead can also be measured using a thermocouple placed on the lead as close as possible to the tie point. The thermal mass connected to the tie point is normally large enough so that it will not significantly respond to heat surges generated in the diode as a result of pulsed operation once steady-state conditions are achieved. Using the measured value of T L, the junction temperature may be determined by:T J = T L + ¨T JL ¨T JL is the increase in junction temperature above the lead temperature and may be found from Figure 2 for a train of power pulses or from Figure 10 for dc power.¨T JL = șLA P DFor worst-case design, using expected limits of Iz, limits of PD and the extremes of TJ (¨T JL ) may be estimated. Changes in voltage, Vz, can then be found from:¨V = șVZ¨T JșVZ , the zener voltage temperature coefficient, isfound from Figures 5 and 6.Under high power-pulse operation, the zener voltagewill vary with time and may also be affected significantly be the zener resistance. For best regulation, keep current excursions as low as possible.Data of Figure 2 should not be used to compute surge capability. Surge limitations are given in Figure 3. They are lower than would be expected by considering only junction temperature, as current crowding effects cause temperatures to be extremely high in small spots resulting in device degradation should the limits of Figure 3 beexceeded.COMCHIPSurface Mount Zener Diode。