HA7-5127-2中文资料
HACH 哈希 SS7高量程在线浊度仪用户手册
6.1 定期维护计划 .................................................................... 37 6.2 从系统中拆除传感器 .............................................................. 37 6.3 在系统上安装传感器 .............................................................. 37
3 安装 ..................................................................................................................................... 13
3.1 基本安装概况 .................................................................... 13 3.2 将仪器拆包 ...................................................................... 13 3.3 机械安装 ........................................................................ 15
IP Korea化学品安全技术说明书 HAY992 INTERTHERM 875 RAL9011 G
IP Korea化学品安全技术说明书HAY992 INTERTHERM 875 RAL9011 GRAPH.BLACK版本 1 版本修订日 07/31/141.化学品及企业标识 1.1.产品名称INTERTHERM 875 RAL9011 GRAPH.BLACK 产品代码HAY9921.2. 纯物质或者混合物的建议用途及禁止用途拟定用途请参阅产品技术说明书仅供专业人员使用施工方法请参阅产品技术说明书1.3.安全技术说明书供应商的信息制造商IP Korea电话号码055-632-6286(研发), 055 586 2310(工厂)传真号码055 632-6287(研发), 055 587 6276(工厂)1.4.应急咨询电话055-586-2310(工厂)中毒咨询电话055-586-2310(工厂) 仅供医生及医院参考2.危险性概述 2.1.纯物质或混合物的分类Flam. Liq. 3;H226易燃液体和蒸气Skin Irrit. 2;H315造成皮肤刺激Eye Irrit. 2;H319造成严重眼刺激STOT SE 3;H335可引起呼吸道刺激2.2.标签要素用第11和12章列出的毒性数据,产品标签如下所示。
警告H226 易燃液体和蒸气。
H315 造成皮肤刺激。
H319 造成严重眼刺激。
H335 可引起呼吸道刺激。
[预防措施]:P210 远离热源/火花/明火/热表面。
禁止吸烟。
P261 避免吸入粉尘/烟/气体/烟雾/蒸气/啧雾。
P264 作业后彻底清洗。
P271 只能在室外或通风良好之处使用。
P280 戴防护手套/戴防护眼罩/戴防护面具。
[事故响应]:P302+352 如皮肤沾染:用大量肥皂和水清洗。
P303+361+353 如皮肤(或头发)沾染:立即脱掉所有沾染的衣服。
用水清洗皮肤/淋浴。
P304+312 如误吸入:如感觉不适,呼叫毒物中心或医生。
P305+351+338 如进入眼睛:用水小心冲洗几分钟。
阀门压力等级对照表
[推荐]阀门压力等级对照表阀门, 等级, 压力,对照表希望对各位海友能有所帮助。
第一章钢制阀门主体和内件材料阀门的主体是指承受介质压力的阀体、阀盖〔或端盖〕、闸板〔或阀瓣〕。
其中,阀体和阀盖〔端盖〕是承受介质的承压件,闸板〔阀瓣〕是控制介质流动的控压件。
内件是指接触介质的阀杆和闸板(阀瓣)、阀座两者的密封面。
承压件的定义是:一旦它们失效,其所包容的介质会释放到大气中的零件。
因此,所用的材料必须能在规定的介质温度、压力作用下到达相应的力学性能、耐腐蚀性和良好的冷、热加工工艺性。
大多数阀门的阀体、阀盖〔端盖〕、闸板〔阀瓣〕形状比较复杂,因此采用铸件较多,只有某些小口径阀门根据阀类的不同或特殊工况的要求采用锻件。
第一节钢制阀门的主体材料1、碳素钢碳素钢适用于非腐蚀性介质,在某些特定的条件下,例如某些有腐蚀性的介质在一定范围内的温度浓度条件下也可采用碳素钢。
碳素钢的适用温度范围:-29~425℃。
中石化标准SH 3064《石油化工钢制通用阀门选用、检验及验收》规定碳素钢制阀门的适用温度范围为-20~425℃,其下限定为-20℃的依据是GB 150《钢制压力容器》。
但当以WCB、WCC这两种钢作阀体、阀盖、闸板〔阀瓣〕、支架时,这两种钢的适用温度下限为-29℃。
常用的碳素钢铸件和锻件材料见表1-1。
注:〔1〕表1中WCA、WCB、WCC是按美国标准表示的牌号,ZG 205-415、ZG 250-485、ZG 275-485是按GB/T 5631铸钢牌号表示方法分别对应WCA、WCB、WCC的牌号。
UNS J02502、UNS J03002、UNS J02503是以美国金属与合金统一系统编号方法,分别对应WCA、WCB、WCC的牌号。
〔2〕表1中最常用的是WCB钢,其标准含碳量≤0.30%,但为了获得优良的焊接性能和力学性能,其含碳量应控制在0.25%左右。
〔3〕残留元素Cr、Ni、Mo、V、Cu也是必须控制并达标,其残留元素总量应≤1%,但有碳当量〔CE〕要求时此条不适用。
ABS塑料性能和部分牌号介绍
ABS塑料性能和部分牌号介绍ABS塑料- ABS树脂是五大合成树脂之一,其抗冲击性、耐热性、耐低温性、耐化学药品性及电气性能优良,还具有易加工、制品尺寸稳定、表面光泽性好等特点,容易涂装、着色,还可以进行表面喷镀金属、电镀、焊接、热压和粘接等二次加工,广泛应用于机械、汽车、电子电器、仪器仪表、纺织和建筑等工业领域,是一种用途极广的热塑性工程塑料。
ABS树脂是目前产量最大,应用最广泛的聚合物,它将PS,SAN,BS的各种性能有机地统一起来,兼具韧、硬、刚相均衡的优良力学性能。
ABS是丙烯腈、丁二烯和苯乙烯的三元共聚物,A代表丙烯腈,B代表丁二烯,S代表苯乙烯。
ABS塑料-名称化学名称丙烯腈-丁二烯-苯乙烯塑料英文名称 Acrylonitrile Butadiene Styrene plasticABS塑料-性能一般性能ABS外观为不透明呈象牙色粒料,其制品可着成五颜六色,并具有高光泽度。
ABS相对密度为1.05左右,吸水率低。
ABS同其他材料的结合性好,易于表面印刷、涂层和镀层处理。
ABS的氧指数为18~20,属易燃聚合物,火焰呈黄色,有黑烟,并发出特殊的臭味。
力学性能ABS有优良的力学性能,其冲击强度极好,可以在极低的温度下使用;ABS 的耐磨性优良,尺寸稳定性好,又具有耐油性,可用于中等载荷和转速下的轴承。
ABS的耐蠕变性比PSF及PC大,但比PA及POM小。
ABS的弯曲强度和压缩强度属塑料中较差的。
ABS的力学性能受温度的影响较大。
热学性能ABS的热变形温度为93~118℃,制品经退火处理后还可提高10℃左右。
ABS 在-40℃时仍能表现出一定的韧性,可在-40~100℃的温度范围内使用。
电学性能ABS的电绝缘性较好,并且几乎不受温度、湿度和频率的影响,可在大多数1环境下使用。
环境性能ABS不受水、无机盐、碱及多种酸的影响,但可溶于酮类、醛类及氯代烃中,受冰乙酸、植物油等侵蚀会产生应力开裂。
硫氰酸铵安全技术说明书中文
化学品安全技术说明书第1部分化学品及企业标识化学品中文名:硫氰酸铵化学品英文名:Ammonium Thiocyanate企业名称:此处填写贵公司名称企业地址:此处填写贵公司地址传真:此处填写贵公司传真联系电话:此处填写贵公司电话企业应急电话:此处填写贵公司应急电话产品推荐及限制用途:For industry use only.。
第2部分危险性概述紧急情况概述:吞咽有害。
皮肤接触有害。
吸入有害。
GHS危险性类别:急性经口毒性类别 4急性经皮肤毒性类别 4急性吸入毒性类别 4危害水生环境——长期危险类别 3标签要素:象形图:警示词:警告危险性说明:H302 吞咽有害。
H312 皮肤接触有害。
H332 吸入有害。
H412 对水生生物有害并具有长期持续影响。
防范说明:•预防措施:•P264 作业后彻底清洗。
•P270 使用本产品时不要进食、饮水或吸烟。
•P280 戴防护手套/穿防护服/戴防护眼罩/戴防护面具。
•P261 避免吸入粉尘/烟/气体/烟雾/蒸气/喷雾。
•P271 只能在室外或通风良好处使用。
•P273 避免释放到环境中。
•事故响应:•P301+P312 如误吞咽:如感觉不适,呼叫解毒中心/ 医生•P330 漱口。
•P302+P352 如皮肤沾染:用水充分清洗。
•P312 如感觉不适,呼叫解毒中心/医生•P321 具体治疗 ( 见本标签上的…… )。
•P362+P364 脱掉沾染的衣服,清洗后方可重新使用•P304+P340 如误吸入:将人转移到空气新鲜处,保持呼吸舒适体位。
•安全储存:•无•废弃处置:•P501 按当地法规处置内装物/容器。
物理和化学危险:无资料健康危害:吞咽有害。
皮肤接触有害。
吸入有害。
环境危害:对水生生物有害并具有长期持续影响。
第3部分成分/组成信息第4部分急救措施急救:吸入: 如果吸入,请将患者移到新鲜空气处。
皮肤接触: 脱去污染的衣着,用肥皂水和清水彻底冲洗皮肤。
如有不适感,就医。
5437 二线制 HART 7 温度变送器 产品手册说明书
C O M M U N I C A T I O N P R O T O C O LNo. 5437V102-CNProduct version: 01.00.00-01.99.99安全栅 | 通讯接口 | 多功能 | 隔离器 | 数显表产品手册 5437二线制 HART 7 温度变送器基于微处理器技术研发的 6 mm 隔离器,小巧精致、响应迅速、品质一流,以极低的总拥有成本为专用应用提供卓越性能和抗电磁干扰。
可水平或垂直安装,装置间无需间隙。
我们采用最严格的安全标准来检验产品,以期提供最安全的信号。
秉承创新精神,我们已经在 SIL 2 全面评估本质安全型接口方面取得了开创性成就,其既高效又经济,效果卓著,成效斐然。
模拟量和数字量本质安全栅种类齐全,同时提供多种输入输出。
这使得 PR 标准成为一项易于实施的现场检验标准。
在大型项目安装过程中,新背板方案大大简化安装和布线,且能与标准 DCS 系统无缝集成。
数显表系列以其灵活性和稳定性著称。
该设备系列几乎满足过程信号读数显示的所有需求,并具有通用的输入和供电能力。
无论哪种行业,无论环境条件何其苛刻,该设备均能实时测量过程值并提供用户友好型界面和值得信赖的继电器信号。
我们提供经济实惠、使用方便、面向未来的通讯接口,以便您能够访问所安装的 PR 产品。
所有接口均可拆卸,并带有屏幕和按钮,可以显示过程值/诊断值和对参数进行配置。
产品特定功能包括通过 Modbus 和蓝牙进行通讯,以及使用我们的便携式设备主管 (PPS) 应用程序进行远程访问,可用于 iOS 和 Android 。
单品为多功能系列产品,可涵盖大量现场应用,可轻而易举按照您的现场标准进行配置。
此种单品可适用多种应用方式,既节省安装和培训时间,又大大简化库存备件管理。
该设备专为长期信号精度高、功耗低、抗电噪声优异、编程简单而设计。
温度变送器和温度传感器系列产品,提供从温度测量点到系统控制一站式信号解决方案,从而在最大程度上保证信号的完整性。
稳压二极管型号对照表
稳压二极管型号对照表美标稳压二极管型号1N4727 3V01N4728 3V31N4729 3V61N4730 3V91N4731 4V31N4732 4V71N4733 5V11N4734 5V61N4735 6V21N4736 6V81N4737 7V51N4738 8V21N4739 9V11N4740 10V1N4741 11V1N4742 12V1N4743 13V1N4744 15V1N4745 16V1N4746 18V1N4747 20V1N4748 22V1N4749 24V1N4750 27V1N4751 30V1N4752 33V1N4753 36V1N4754 39V1N4755 43V1N4756 47V1N4757 51V需要规格书请到以下地址下载,/products/Rectifiers/Diode/Zener/经常看到很多板子上有M记的铁壳封装的稳压管,都是以美标的1N系列型号标识的,没有具体的电压值,刚才翻手册查了以下3V至51V的型号与电压的对照值,希望对大家有用1N4727 3V01N4728 3V31N4729 3V61N4730 3V91N4731 4V31N4733 5V11N4734 5V61N4735 6V21N4736 6V81N4737 7V51N4738 8V21N4739 9V11N4740 10V1N4741 11V1N4742 12V1N4743 13V1N4744 15V1N4745 16V1N4746 18V1N4747 20V1N4748 22V1N4749 24V1N4750 27V1N4751 30V1N4752 33V1N4753 36V1N4754 39V1N4755 43V1N4756 47V1N4757 51VDZ是稳压管的电器编号,是和1N4148和相近的,其实1N4148就是一个0.6V 的稳压管,下面是稳压管上的编号对应的稳压值,有些小的稳压管也会在管体上直接标稳压电压,如5V6就是5.6V的稳压管。
哈希产品样本
■ RS232/SDI 12:
通过 VOTA 多功能单元或笔记本 电脑进行数据通讯(数据读取,参数 化)与多种数据传输接口,如: - 串口连接调制解调器(GSM 或 landline) - 微波,卫星等
NIMBUS 对于个别测量点的单独测量 可在现场完成。
应用范例
除了常规应用外,Kalesto 还用于以下场合: 咸水,排水沟,波浪起伏比较大的河流 -不接触测量介质 灌溉渠道等 -可通过一伸出臂进行简单的安装 含有大量悬浮物的河流,山间小溪,干涸的河流等 -不受淤泥的影响; -当河流测量断面变化时(低流量),相对于在监测室内的仪器以及需在测井中或管道中工作的仪器来说传感器移动更方便。
■ 即使在盐水或受污染水 体中,非直接的气泡测 量原理也能提供准确的 读数和长期的稳定性。 每次测量前能自动进行 零点校正。
·2·
水位监测
<MIDI>防护外壳 防护外壳用来保护
NIMBUS感应卡和充气装 置并且辅助墙壁安装程序
■ 红外数据接口 - 通过 VOTA 多功能单元,笔记 本电脑和掌上电脑进行现场数据 读取和参数设置 - 对湿度和灰尘不敏感 - 易于操作
0.3 mA 通常 180mA,最大 350mA 最大 100m 238mm × 62mm × 100mm 约 0.860kg -20 - 60℃
·4·
水位监测
OTT Kalesto
Kalesto 雷达液位计是一种先进的测量地表水位的新型测量方法,它在水文野外测量中具有 许多优点。Kalesto 是 OTT 公司生产的独特的非接触式水位测量仪。该传感器安装方便、空间占 有率低,所耗时间和金钱都很少,性价比好,设计紧凑,不与水面接触。Kalesto 在测量中不受 高水位,淤泥,水上垃圾,植物生长等因素的影响,免维护。
过硫酸铵安全数据表
标识
中文名称:过硫酸铵
CAS:7727-54-0
中文别名:过二硫酸铵,高硫酸铵
RTECS:
英文名称:Ammonium persulfate
危编号:51504
分子式:(NH4)2S2O8
分子量:228.20
理化性质
外观与性状:无色单斜晶体,有时略带浅绿色,有潮解性。
沸点(℃):
熔点(℃):
急救措施
皮肤接触:立即脱去污染的衣着,用大量流动清水冲洗至少15分钟。就医。
眼睛接触:立即提起眼睑,用大量流动清水或生理盐水彻底冲洗至少15分钟。就医。
吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给输氧。如呼吸停止,立即进行人工呼吸。就医。
食入:用水漱口,给饮牛奶或蛋清。就医。
呼吸系统防护:可能接触其粉尘时,应该佩戴头罩型电动送风过滤式防尘呼吸器。高浓度环境中,建议佩戴自给式呼吸器
操作注意事项
密闭操作,局部排风。操作人员必须经过专门培训,严格遵守操作规程。建议操作人员佩戴头罩型电动送风过滤式防尘呼吸器,穿聚乙烯防毒服,戴橡胶手套。远离火种、热源,工作场所严禁吸烟。避免产生粉尘。避免与还原剂、活性金属粉末接触。搬运时要轻装轻卸,防止包装及容器损坏。禁止震动、撞击和摩擦。配备相应品种和数量的消防器材及泄漏应急处理设备。倒空的容器可能残留有害物。
眼睛防护:呼吸系统防护中已作防护。
身体防护:穿聚乙烯防毒服
手防护:戴橡胶手套
其它:工作现场禁止吸烟、进食和饮水。工作完毕,彻底清洗。注意个人清洁卫生。
泄漏应急处置
隔离泄漏污染区,限制出入。建议应急处理人员戴防尘面具(全面罩),穿防毒服。不要直接接触泄漏物。勿使泄漏物与还原剂、有机物、易燃物或金属粉末接触。小量泄漏:用砂土、干燥石灰或苏打灰混合。收集于干燥、洁净、有盖的容器中。也可以用大量水冲洗,洗水稀释后放入废水系统。大量泄漏:收集回收或运至废物处理场所处置。
铝合金ha7化学成分
铝合金ha7化学成分全文共四篇示例,供读者参考第一篇示例:铝合金HA7是一种高性能铝合金材料,具有优异的力学性能和耐腐蚀性能。
其化学成分主要包括铝、镁、锌、铜等元素。
铝作为基础元素,具有轻便、耐腐蚀、导电性能良好等特点,而镁、锌、铜等合金元素则能够提高材料的强度和硬度。
铝合金HA7的铝含量一般达到90%以上,是其主要成分。
铝是一种轻金属,密度小、耐腐蚀、具有优良的导热和导电性能,所以铝合金HA7材料具有较轻的重量和良好的耐腐蚀性能。
镁是铝合金HA7中的重要合金元素之一。
镁的添加能够有效提高合金的强度和硬度,同时还能提高合金的耐热性能。
锌是铝合金HA7中的另一种常见合金元素。
锌的加入能够有效提高合金的强度和耐腐蚀性能,同时还具有一定的硬化作用。
铜也是铝合金HA7中的常见合金元素之一。
铜能够有效增加合金的强度和硬度,同时还能提高铝合金的耐热性。
铝合金HA7是一种优质的铝合金材料,具有良好的力学性能和耐腐蚀性能。
其化学成分包括铝、镁、锌、铜等元素,使其具有较高的强度和硬度。
在工程领域中,铝合金HA7被广泛应用于航空航天、汽车制造、建筑工程等领域。
随着科技的不断发展,铝合金HA7将会更加广泛地应用于各个领域,为人们的生活和工作提供更好的支持和保障。
第二篇示例:铝合金是一种重要的工业材料,具有优异的性能和广泛的应用领域。
铝合金HA7是一种常见的铝合金材料,其化学成分对其性能和用途有着重要影响。
本文将从铝合金HA7的化学成分、性能特点、应用领域等方面进行详细介绍。
铝合金HA7的化学成分通常包括铝、锰、镁、铜、矽和锆等元素。
铝是铝合金的基本成分,占比最大,通常在85%以上。
锰主要用于增强硬度和强度,一般含量在0.5%~1.2%之间。
镁是一种常见的合金元素,可提高铝合金的强度和耐热性,含量一般在0.3%~0.9%之间。
铜和矽主要用于提高合金的强度和耐腐蚀性能,含量分别在0.1%~0.5%和0.2%~0.8%之间。
HA-5147中文资料
Temperature Range HA-5147-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55oC to 125oC HA-5147-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0oC to 75oC HA-5147-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40oC to 85oC
Electrical Specifications VSUPPLY = ±15V, CL ≤ 50pF, RS ≤ 100Ω
PARAMETER
TEST CONDITIONS
TEMP. (oC)
MIN
TYP
MAX
UNITS
INPUT CHARACTERISTICS
Offset Voltage
25
-
30
100
Thermal Information
Thermal Resistance (Typical, Note 2)
θJA (oC/W) θJC (oC/W)
CERDIP Package. . . . . . . . . . . . . . . . . 135
50
SOIC Package . . . . . . . . . . . . . . . . . . . 158
Using the HA-5147 allows designers to minimize errors while maximizing speed and bandwidth in applications requiring gains greater than ten.
哈迪兰产品公司安全数据表说明书
HAVILAND PRODUCTS COMPANYSAFETY DATA SHEETSection 1: IdentificationProduct Name: Havaclean Hand Sanitizer-E Product Code:H006616Haviland Products Company 421 Ann Street NWGrand Rapids, MI 49504 (616) 361-6691Emergency Phone:CHEMTREC: Canada and USA - (800) 424-9300 CHEMTREC:In Mexico - 01-800-681-9531Product Use: Hand SanitizerNot recommended for: NASection 2: Hazard(s) IdentificationGHS Ratings:Flammable liquid2Skin corrosive3Eye corrosive2BOrgan toxin single exposure3Organ toxin repeated exposure 1Flash point < 23°C and initial boiling point > 35°C (95°F)Reversible adverse effects in dermal tissue, Draize score: >=1.5 <2.3Mild eye irritant: Subcategory 2B, Reversible in 7 daysTransient target organ effects- Narcotic effects- Respiratorytract irritationSignificant toxicity in humans- Reliable, good quality humancase studies or epidemiological studies Presumedsignificant toxicity in humans- Animal studies with significantand/or severe toxic effects relevant to humans at generallylow exposure (guidanc e)GHS HazardsH225Highly flammable liquid and vapour H316Causes mild skin irritationH320Causes eye irritationH335May cause respiratory irritationH336May cause drowsiness ordizzinessH372Causes damage to organsthrough prolonged or repeatedexposure GHS PrecautionsP210Keep away from heat/sparks/openflames/hot surfaces – No smokingP233Keep container tightly closedP240Ground/bond container and receivingequipmentP241Use explosion-proofelectrical/ventilating/light/equipmentP242Use only non-sparking toolsP243Take precautionary measures againststatic dischargeP260Do not breathedust/fume/gas/mist/vapors/sprayP261Avoid breathingdust/fume/gas/mist/vapors/sprayP264Wash face, hands, and any exposedskin thoroughly after handlingP270Do not eat, drink or smoke when usingthis productP271Use only outdoors or in a well-ventilatedareaPowered by Plymouth Technolog yP280Wear protective gloves/protective clothing/eye protection/face protection P312Call a POISON CENTER ordoctor/physician if you feel unwellP314Get Medical advice/attention if you feel unwellP303+P361+P353If on skin (or hair): Remove / Take off immediately all contaminated clothing. Rinse skin with water / shower.P304+P340If inhales: Remove victim to fresh air and keep at rest in a position comfortable for breathing.P305+P351+P338If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.P332+P313If skin irritation occurs: Get medical advice / attentionP337+P313If eye irritation persists get medical advice / attentionP370+P378In case of fire: Use suitable media for extinctionP405Store locked upP403+P233Store in a well-ventilated place. Keep container tightly closed.P403+P235Store in a well ventilated place. Keep coolP501Dispose of contents/container in accordance withlocal/regional/national/international regulationsDangerSection 3: Composition/Information on IngredientsChemical Name / CAS No.OSHA Exposure Limits ACGIH Exposure Limits Other Exposure LimitsEthyl alcohol 64-17-570% - 80%Vapor Pressure: 42.979 mmHg1000 ppm TWA; 1900 mg/m3 TWA1000 ppm STELNIOSH: 1000 ppmTWA; 1900 mg/m3 TWAGlycerin 56-81-51% - 5%Vapor Pressure: .002 mmHg15 mg/m3 TWA (mist, total particulate); 5 mg/m3 TWA (mist, respirable fraction)Hydrogen peroxide 7722-84-10.1% - 1.0%1 ppm TWA; 1.4 mg/m3 TWA1 ppm TWANIOSH: 1 ppm TWA; 1.4 mg/m3 TWASection 4: First-aid MeasuresInhalationRescuers should put on appropriate protective gear. Remove from area of exposure. If not breathing,give artificial respiration. If breathing is difficult, give oxygen. Keep victim warm. Get immediate medical attention. Toprevent aspiration, keep head below knees.Eye ContactImmediately flush eyes with water. Flush eyes with water for a minimum of 15 minutes, occasionallylifting and lowering upper lids. Get medical attention promptly.Skin ContactRemove contaminated clothing. Wash skin with soap and water. Get medical attention. Wash clothingseparately and clean shoes before reuse.IngestionIf swallowed, do NOT induce vomiting. Give victim a glass of water. Call a physician or poison control centerimmediately. Never give anything by mouth to an unconscious person.Section 5: Fire-fighting MeasuresExtinguishing MediaWater spray. Alcohol-resistant foam. BC powder. Carbon dioxide.Do not use: Solid water jet ineffective as extinguishing medium.Specific Hazards Arising from the ChemicalDIRECT FIRE HAZARD. Highly flammable. Gas/vapour flammable with air within explosion limits.INDIRECT FIRE HAZARD. May be ignited by sparks. Gas/vapour spreads at floor level:ignition hazard. Reactions involving a fire hazard: see "Reactivity Hazard".Explosion hazard : DIRECT EXPLOSION HAZARD. Gas/vapour explosive with air within explosion limits.INDIRECT EXPLOSION HAZARD. may be ignited by sparks. Reactions with explosion hazards:see "Reactivity Hazard".Special Protective Equipment and Precautions for FirefightersSpecial Information: As in any fire, wear self-contained breathing apparatus pressure-demand (MSHA / NIOSHapproved or equivalent) and full protective gear.Section 6: Accidental Release MeasuresSpill and Leak ProceduresRemove ignition sources. Use special care to avoid static electric charges. No naked lights. Nosmoking.Keep upwind. Mark the danger area. Consider evacuation. Seal off low-lying areas.Close doors and windows of adjacent premises. Stop engines and no smoking. No naked flamesor sparks.Spark- and explosion-proof appliances and lighting equipment. Keep containersclosed. Wash contaminated clothes.Clean up methods:Take up liquid spill into a non combustible material e .g.: sand, earth, vermiculite or powderedlimestone. Scoop absorbed substance into closing containers. See "Material-handling"forsuitable container materials. Carefully collect the spill/leftovers. Damaged/cooled tanks must beemptied. Do not use compressed air for pumping over spills. Clean contaminated surfaces withan excess of water. Take collected spill to manufacturer/competent authority . Wash clothing andequipment after handling.Section 7: Handling and StoragePrinted: 4/6/2020 at 2:51:41PMHandling ProceduresProper grounding procedures to avoid static electricity should be followed. Ground/bond container and receiving equipment. Use explosion-proofelectrical/ventilating/lighting/equipment.Use with adequate ventilation. Avoid breathing dusts, mists, and vapors. Do not get in eyes, on skin, or on clothing. Wear eye protection and protective clothing . Wash thoroughly after handling.Storage RequirementsKeep container tightly closed. Keep only in the original container in a cool, well ventilated place away from : incompatible materials. Keep in fireproof place.Incompatible products : Strong bases. Strong acids.Incompatible materials : Sources of ignition. Direct sunlight. Heat sources.Heat and ignition sources : KEEP SUBSTANCE AWAY FROM: heat sources. ignition sources.Prohibitions on mixed storage : KEEP SUBSTANCE AWAY FROM: oxidizing agents. (strong) acids. water/moisture.Storage area : Keep out of direct sunlight. Store in a dry area. Ventilation at floor level. Fireproof storeroom.Provide for an automatic sprinkler system. Provide for a tub to collect spills. Provide the tank with earthing. Meet the legal requirements.Special rules on packaging : SPECIAL REQUIREMENTS: closing. dry. clean. correctly labelled. meet the legal requirements.Secure fragile packagings in solid containers.Packaging materials : SUITABLE MATERIAL: stainless steel. aluminium. iron. copper. nickel. synthetic material. glass.Section 8: Exposure Control/Personal ProtectionOther Exposure LimitsACGIH Exposure Limits OSHA Exposure Limits Chemical Name / CAS No.1000 ppm TWA; 1900 mg/m3 TWA1000 ppm STELNIOSH: 1000 ppm TWA; 1900 mg/m3 TWAEthyl alcohol 64-17-515 mg/m3 TWA (mist, total particulate); 5 mg/m3 TWA (mist, respirable fraction)Glycerin 56-81-51 ppm TWA; 1.4 mg/m3 TWA1 ppm TWANIOSH: 1 ppm TWA; 1.4 mg/m3 TWAHydrogen peroxide 7722-84-1ENGINEERING CONTROLS: Provide ventilation sufficient to maintain exposure below the recommended limits.RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be followed whenever workplace conditions warrant the use of a respirator.SKIN PROTECTION: Wear impervious protective gloves. Wear protective gear as needed - apron, suit, boots. EYE PROTECTION: Wear safety glasses with side shields (or goggles) and a face shield.OTHER PROTECTIVE EQUIPMENT : Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower.HYGENIC PRACTICES: Do not eat, drink, or smoke in areas where this material is used. Avoid breathing vapors. Remove contaminated clothing and wash before reuse. Wash thoroughly after handling. Wash hands before eating.Section 9: Physical and Chemical PropertiesClear Colorless Liquid Appearance:AlcoholOdor:Not Available Vapor Pressure:Not AvailableOdor threshold:1.6Vapor Density: 6.5 - 8.5pH:Not AvailableDensity:Not AvailableMelting point:Not Available Freezing point:Complete Solubility:70° CBoiling range:25° C Flash point:8.3Evaporation rate (Ether=1):Not Available Flammability:Not AvailableExplosive Limits:0.837Specific Gravity Not AvailableAutoignition temperature:Not AvailableDecomposition temperature:Not Available Viscosity:Not AvailableGrams VOC less water:Section 10: Stability and Reactivity Chemical Stability:STABLEIncompatible MaterialsStrong acids. Strong bases.Conditions to AvoidDirect sunlight. Extremely high or low temperatures. Open flame.Hazardous Decomposition ProductsFume. Carbon monoxide. Carbon dioxide. May release flammable gases.Hazardous PolymerizationHazardous polymerization will not occur.Section 11: Toxicology InformationMixture ToxicityInhalation Toxicity LC50: 150mg/L Component Toxicity7722-84-1Hydrogen peroxideOral LD50: 801 mg/kg (Rat) Dermal LD50: 4,060 mg/kg (Rat) Inhalation LC50: 2 g/m3 (Rat)Routes of Entry:Inhalation Ingestion Skin contact Eye contactTarget OrgansBlood Eyes KidneysLiver Central Nervous System Reproductive System SkinRespiratory System Effects of OverexposureCarcinogen Rating CAS Number Description% Weight Hydrogen peroxide:7722-84-1Hydrogen peroxide 0.1% - 1.0%Section 12: Ecological InformationComponent Ecotoxicity Ethyl alcohol96 Hr LC50 Oncorhynchus mykiss: 12.0 - 16.0 mL/L [static]; 96 Hr LC50Pimephales promelas: >100 mg/L [static]; 96 Hr LC50 Pimephales promelas: 13400 - 15100 mg/L [flow-through]48 Hr LC50 Daphnia magna: 9268 - 14221 mg/L; 48 Hr EC50 Daphnia magna: 2 mg/L [Static]Glycerin96 Hr LC50 Oncorhynchus mykiss: 51 - 57 mL/L [static]Hydrogen peroxide96 Hr LC50 Pimephales promelas: 16.4 mg/L; 96 Hr LC50 Lepomis macrochirus:18 - 56 mg/L [static]; 96 Hr LC50 Oncorhynchus mykiss: 10.0 - 32.0 mg/L [static]48 Hr EC50 Daphnia magna: 18 - 32 mg/L [Static]Section 13: Disposal ConsiderationsDispose of in accordance with local, state and federal regulations.Section 14: Transportation InformationUN Code: 1993Proper Shipping Name: Flammable liquid, N.O.S. (Ethanol)Hazard Class: 3Packing Group: IIISection 15: Regulatory InformationOSHA Process Safety Management Highly Hazardous Chemicals7722-84-1 Hydrogen peroxideTSCA 8(b) Inventory7722-84-1 Hydrogen peroxide56-81-5 Glycerin64-17-5 Ethyl alcoholRegulationCountryAll Components ListedSection 16: Other InformationDate Prepared: 4/6/2020DisclaimerThe information herein is believed to be correct, but does not claim to be all inclusive and should beused only as a guide. Neither the above named supplier nor any of its affiliates or subsidiaries assumesany liability whatsoever for the accuracy or completeness of the information contained herein. Finaldetermination of suitability of any material is the sole responsibility of the user. All chemical reagentsmust be handled with the recognition that their chemical, physiological, toxicological, and hazardousproperties have not been fully investigated or determined. All chemical reagents should be handledonly by individuals who are familiar with their potential hazards and who have been fully trained in propersafety, laboratory, and chemical handling procedures. Although certain hazards are described herein,we can not guarantee that these are the only hazards which exist. Our SDS are based only on dataavailable at the time of shipping and are subject to change without notice as new information is obtained.Avoid long storage periods since the product is subject to degradation with age and may become moredangerous or hazardous. It is the responsibility of the user to request updated SDS for products that arestored for extended periods. Disposal of unused product must be undertaken by qualified personnelwho are knowledgeable in all applicable regulations and follow all pertinent safety precautions includingthe use of appropriate protective equipment (e.g. protective goggles, protective clothing, breathingequipment, face mask, fume hood). For proper handling and disposal, always comply with federal, stateand local regulations.。
ISO7637-2中文资料(电源线瞬态传导干扰抗扰性试验)
ISO7637-2(2004)标准电源线瞬态传导干扰抗扰性试验前言GB/T21437《道路车辆由传导和耦合引起的电骚扰》包括三个部分:——第1部分:定义和一般描述;——第2部分:沿电源线的电瞬态传导;——第3部分:除电源线外的导线通过容性和感性耦合的电瞬态发射。
本部分为GB/T21437的第2部分,等同采用ISO7637—2:2004《道路车辆由传导和耦合引起的电骚扰第2部分:沿电源线的电瞬态传导》制定。
编辑性修改为:在表1中对U A、U B加注。
本部分附录A、附录C、附录D为规范性附录,附录B、附录E、附录F为资料性附录。
本部分由国家发展与改革委员会提出。
本部分由全国汽车标准化技术委员会归口。
本部分起草单位:中国汽车技术研究中心。
本部分参加起草单位:上海大众汽车有限公司、信息产业部电信传输研究所、长沙汽车电器研究所。
本部分主要起草人:徐立、刘欣、刘新亮、邹东屹、胡梦蛟、林艳萍。
道路车辆由传导和耦合引起的电骚扰第2部分:沿电源线的电瞬态传导1范围本部分规定了安装在乘用车及12V电气系统的轻型商用车或24V电气系统的商用车上设备的传导电瞬态电磁兼容性测试的台架试验,包括瞬态注入和测量。
本部分还规定了瞬态抗扰性失效模式严重程度分类。
本部分适用于各种动力系统(例如火花点火发动机或柴油发动机,或电动机)的道路车辆。
2规范性引用文件下列文件中的条款通过GB/T21437的本部分的引用而成为本部分的条款。
凡是标注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本部分。
然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。
凡是不标注日期的引用文件,其最新版本适用于本部分。
GB/T21437.1道路车辆由传导和耦合引起的电骚扰第1部分:定义和一般描述(GB/T 21437.1—2008,ISO7637-l:2002,IDT);ISO8854:1988道路车辆带调节器的交流发电机试验方法和一般要求Roadand general requirements vehicles—Alternatorswith regulators—Testmethods3术语和定义GB/T21437.1确立的术语和定义适用于本部分。
API 7K 第5版中文版
7.7质量控制要求...................................................................15
8.2 质量控制人员资格...............................................................16
8.3测试设备.......................................................................16
5设计验证..........................................................................8
5.1总则............................................................................8
7焊接要求.........................................................................15
7.1总则...........................................................................15
9.7 活塞泥浆泵零部件...............................................................31
9.8绞车零部件.....................................................................55
HA12175中文资料
Audio Signal Processor for Car Deck and Cassette Deck (Dolby B/C-type NR with PB Amp)
ADE-204-016 1st Edition Nov. 1992 Description
HA12173 series are silicon monolithic bipolar IC providing Dolby noise reduction system*, music sensor and PB equalizer system in one chip.
1, 5, 38, 42 NC
No connection
6
HA12173 Series
Block Diagram
RADIO IN(L) PBOUT(L)
RECOUT(L)
EQOUT(L)
+
42 43
120/70
41
40
RIP
39
38
37
36
35
34
33
32
31
30
29 2
MA OUT VREF
12, 31 8, 35 44, 55
REC OUT SS2 EQ OUT-M
GND
4
HA12173 Series
Pi n Descri pti on (VCC = 9 V Single supply, Ta = 25°C, No signal , The val ue in the ta ble show typical value) (cont)
Pin No. 43, 56 Terminal name EQ OUT Zin — DC voltage Equivalent circuit VCC/2 V CC Description Equalizer output
氢化钠物料安全数据表
标
识
中文名:氢化钠
英文名:Sodiumhydride
危序号:1661
分子式:NaH
分子量:24
UN号:1427
危险性类别:遇水放出易燃气体的物质和混合物,类
别1
CAS号:7647-69-7
理化性质
外观与性状:白色至淡灰色的细微结晶,以25—50%比例分散在油中。
溶解性:不溶于液氨、苯、二硫化碳、熔融的氢氧化钠。
引燃温度/C:无资料
爆炸极限/%:无资料
稳定性:不稳定
爆炸物质级别、组别:
禁配物:酸类、醇类、水、二氧化碳、强氧化剂、氧、卤素。
危险特性:化学反应活性很高,在潮湿空气中能自燃。遇酸类、水、卤素和氧化剂等能发生强烈的化学反应,引起燃烧或爆炸。
灭火方法:砂土、干粉。禁止用水。禁止用泡沫。
毒
性
侵入途径:吸入、食入、经皮吸收毒性:无资料
防
护
工程控制:密闭操作。呼吸系统防护:可能接触其粉尘时,佩带防毒面具。眼睛防护:戴安全防护眼镜。防护服:穿相应的防护服。手防护:戴防护手套。其他:工作现场严禁吸烟。注意个人清洁卫生。
泄漏处理
隔离泄漏污染区,周围设警告标志,切断火源。建议应急处理人员戴好防毒面具,穿化学防护服。不要直接接触泄漏物,禁止向泄漏物直接喷水,更不要让水进入包装容器内。避免扬尘,使用无火花工具收集逐渐加入干燥的异丙醇内,放置24小时,经稀释后放入废水系统。如果大量泄漏,用塑料布、帆布覆盖,与有关技术部门联系,确定清除方法。
储
运
储存于高燥清洁的仓间内。相对湿度保持在75%以下。远离火种、热源。防止阳光直射。保持容器密封。在氮气中操作处置。应与氧化剂、酸类分开存放。平时需勤检查,查仓温,查混储。搬运时要轻装轻卸,防止包装及容器损坏。雨天不宜运输。
Hysol AM 化学品安全技术说明书
化学品安全技术说明书Hysol AM制造商供应商碧辟 (中国)工业油品有限公司中国上海市浦东新区浦建路76号由由国际广场19~22楼, 电话+86 21 38605888, 邮编: 200127Carechem: +86 10 5100 3039 (24 hours)紧急电话号码冷却润滑液如果需要特殊用途建议, 请参考恰当的技术数据表或者咨询我们公司的代表。
物质/制程的使用457554-CN04产品代码457554安全技术说明书号码物质或混合物相关的确定的用途和使用防止建议警示词危险危险性说明防范说明预防措施事故响应P332 + P313 - 如出现皮肤刺激或皮疹: 就医。
P305 + P351 + P338 + P310 - 接触眼睛: 用水细心冲洗数分钟。
如戴隐形眼镜并可方便地取出,取出隐形眼镜。
继续冲洗。
立即呼叫中毒控制中心或就医。
安全储存不适用。
废弃处置不导致分类的其他危险使皮肤脫脂。
高精制矿物油、乳化剂及添加剂。
职业暴露限制, 如果有的话, 列在第 8 节中。
禁止催吐,除非有专业医疗人士指导。
切勿给失去意识者任何口服物。
如失去知觉,应置于康复位置并立即寻求医疗救治。
化学烧伤必须立即由医生治疗。
如果当事人神智清醒,请用水清洗口腔。
立即就医。
如接触,请立即以大量清水冲洗眼睛至少 15 分钟。
将眼皮翻开冲洗,以确保彻底洗净。
检查和取出任何隐形眼镜。
化学烧伤必须立即由医生治疗。
立即就医。
如接触,请立即以大量清水冲洗皮肤至少 15 分钟并脱去污染的衣物与鞋子。
用肥皂与水彻底清洗皮肤,或使用认可的皮肤清洁剂清洗。
脱下被污染的衣物前请用水彻底冲洗,或者戴手套。
化学烧伤必须立即由医生治疗。
衣物重新使用前应清洗。
鞋子在重新使用前应彻底清洗。
立即就医。
在火灾时吸入分解产品后,症状可能延迟才出现。
如吸入,移至空气新鲜处。
受到暴露的患者须医疗观察 48小时。
立即就医。
眼睛接触皮肤接触吸入食入医生注意事项在火灾时吸入分解产品后,症状可能延迟才出现。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
This device is ideally suited for low level transducer signal amplifier circuits. Other applications which can utilize the HA-5127’s qualities include instrumentation amplifiers, pulse amplifiers, audio preamplifiers, and signal conditioning circuits. This device can easily be used as a design enhancement by directly replacing the 725, OP25, OP06, OP07, OP27 and OP37. For the military grade product, refer to the HA-5127/883 data sheet.
Copyright Intersil Americas Inc. 2002, 2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
元器件交易网
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
This amplifier’s impressive list of features include low VOS (10µV), wide unity gain-bandwidth (8.5MHz), high open loop gain (1800V/mV), and high CMRR (126dB). Additionally, this flexible device operates over a wide supply range (±5V to ±15V) while consuming only 140mW of power.
25
-
10
25
Full
-
30
60
Average Offset Voltage Drift
Ordering Information
PART NUMBER (BRAND)
HA7-5127A-5
HA9P5127-5 (H51275)
HA9P5127-5Z (H51275Z) (Note)
TEMP. RANGE (oC)
PACKAGE
0 to 75 8 Ld CERDIP
0 to 75 8 Ld SOIC
HA-5127, HA-5127A
Absolute Maximum Ratings
Supply Voltage Between V+ and V- Terminals . . . . . . . . . . . . . 44V Differential Input Voltage (Note 3) . . . . . . . . . . . . . . . . . . . . . . . 0.7V Output Current . . . . . . . . . . . . . . . . . . . . Full Short Circuit Protection
Maximum Junction Temperature (Plastic Package) . . . . . . . .150oC
Maximum Storage Temperature Range . . . . . . . . . -65oC to 150oC
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . 300oC
0 to 75
8 Ld SOIC (Pb-free)
PKG. DWG. # F8.3A M8.15
M8.15
HA9P5127-5ZX96 8 Ld SOIC Tape and Reel (H51275Z) (Note) (Pb-free)
M8.15
NOTE: Intersil Pb-free plus anneal products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination finish, which are RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020.
元器件交易网
®
Data Sheet
HA-5127, HA-5127A
July 27, 2005
FN2906.6
8.5MHz, Ultra-Low Noise Precision Operational Amplifier
The HA-5127 monolithic operational amplifier features an unparalleled combination of precision DC and wideband high speed characteristics. Utilizing the Intersil D. I. technology and advanced processing techniques, this unique design unites low noise (3nV/√Hz) precision instrumentation performance with high speed (10V/µs) wideband capability.
Applications
• High Speed Signal Conditioners • Wide Bandwidth Instrumentation Amplifiers • Low Level Transducer Amplifiers • Fast, Low Level Voltage Comparators • Highest Quality Audio Preamplifiers • Pulse/RF Amplifiers
Electrical Specifications VSUPPLY = ±15V, CL < 50pF, RS < 100Ω
PARAMETER
TEST CONDITIONS
TEMP. (oC)
HA-5127A MIN TYP MAX
INPUT CHARACTERISTICS
Offset Voltage
Operating Conditions
Temperature Range HA5127/27A-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0oC to 75oC
Thermal Information
Thermal Resistance (Typical, Note 2)
(SOIC - Lead Tips Only)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Pinout
HA-5127 (CERDIP, SOIC)
TOP VIEW
BAL 1
-IN 2
-
+IN 3
+
V- 4
8 BAL 7 V+ ห้องสมุดไป่ตู้ OUT 5 NC
Features
• Slew Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10V/µs • Unity Gain Bandwidth. . . . . . . . . . . . . . . . . . . . . . 8.5MHz • Low Noise . . . . . . . . . . . . . . . . . . . . . . . 3nV/√Hz at 1kHz • Low VOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10µV • High CMRR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126dB • High Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800V/mV • Pb-Free Plus Anneal Available (RoHS Compliant)