S7-300模块

合集下载

西门子S7-300系列SM331型号8路分析输入模块数据表说明书

西门子S7-300系列SM331型号8路分析输入模块数据表说明书

No
to terminal)
Interrupts/diagnostics/status information Alarms ● Diagnostic alarm ● Limit value alarm Diagnostic messages ● Diagnostic functions ● Diagnostic information readable ● Diagnostics Diagnostics indication LED ● Group error SF (red)
integrating
16 bit; Unipolar: 15/15/15/15 bits; bign/15 bits + sign/15 bits + sign/15 bits + sign Yes; 10/ 16.67/ 20/ 100 ms 10 / 50 / 60 / 400 Hz
8 50 V; Permanent
32 mA
Yes Yes No No No
No Yes 2 MΩ No No Yes 2 MΩ
6ES7331-7NF00-0AB0 Page 1/4
13.05.2015
Changes preserved © Copyright Siemens AG
● -2.5 V to +2.5 V ● -250 mV to +250 mV ● -5 V to +5 V ● Input resistance (-5 V to +5 V) ● -50 mV to +50 mV ● -500 mV to +500 mV ● -80 mV to +80 mV Input ranges (rated values), currents ● 0 to 20 mA ● Input resistance (0 to 20 mA) ● -10 mA to +10 mA ● -20 mA to +20 mA ● Input resistance (-20 mA to +20 mA) ● -3.2 mA to +3.2 mA ● 4 mA to 20 mA ● Input resistance (4 mA to 20 mA) Input ranges (rated values), thermoelements ● Type B ● Type E ● Type J ● Type K ● Type L ● Type N ● Type R ● Type S ● Type T ● Type U ● Type TXK/TXK(L) to GOST Input ranges (rated values), resistance thermometer ● Cu 10 ● Ni 100 ● Ni 1000 ● LG-Ni 1000 ● Ni 120 ● Ni 200 ● Ni 500 ● Pt 100 ● Pt 1000 ● Pt 200 ● Pt 500 Input ranges (rated values), resistors

S7-300 通用型开关量输出扩展模块(SM322)技术规范及接线图

S7-300  通用型开关量输出扩展模块(SM322)技术规范及接线图

0.6 A
•40 - 60℃时
“1”信号允许

5 mA
围,最大
•“1”信号
最小负载电流
•“1”信号
允许的浪涌电 0.5 mA
流,最大
•“0”信号 残余电流,最大
输出总电流 ( 每组)
垂直安装位置 2A
•最高 40℃ 时,最大
水平安装位置
4A
•最高 40℃
时,最大
•最高 50℃
时,最大
3A
•最高 60℃
700000(120VAC,2A 时)100000(230VAC,2A 时)

3A 时),
100000 (230VAC,5A
100000(230VAC,3A 时)
时)
继电器触点
的开关能力
3A;3A(230VAC),2A 5A;5A(230VAC),5A 2A;2A(230VAC),2A (24VDC)
10 mA
10 mA
1A
1A
10 mA
10 mA
20A;最大 1AC 周期 20A;2 个半波
2 mA
2 mA
0.5 A 10 mA 20A;2 个半波
2 mA
1A
10 mA
10A;每组(2 个 AC 周期)
5 mA
2 mA
垂直安装位

4A
2A
•最高 40℃时,最大
4A
水平安装位

4A
2A
•最高 40℃时,最大
×

√;参数可赋 ×

绝缘
500 V DC 500 V DC 500 V DC 500 V DC 1500 V AC 1500 V AC

S7-300功能模块添加说明

S7-300功能模块添加说明

S7-300功能添加说明2008-6-5 施1、组织块(OB)使用说明1.1 OB功能说明:一般情况下,S7-300的PLC使用的组织块(OB)有OB1、OB35、OB80、OB81、OB82、OB84、OB85、OB86、OB100、B121、OB122OB1:启动结束或OB1 执行结束OB35:循环中断5(默认时间间隔:100ms)OB80:时间故障OB81:电源故障OB82:诊断中断OB84:CPU 硬件故障OB85:程序故障OB86:扩展机架、DP 主站系统或分布式OB100:暖启动OB121:编程故障OB122:I/O 访问故障1.2OB组织块建立说明:一、在右侧右击鼠标“右键”会弹出一个窗口如下,二、选择“Insert New Object”将会弹出下一级子窗口三选择“Organization Block”并单击,弹出以下对话框在“Name”里写入需要的组织块(OB),点击“”就可以了,如写入 OB35、OB80、OB81、OB82、OB84、OB85、OB86、OB100、B121、OB1222.1 FC功能说明:FC 相当于一个子程序,在里面可以由用户编写自己所需要的程序,最后在OB1中调用所有建立的FC即可,FC不具有断电保持功能,但是需要断电保持的话,可以调用数据块DB,所有的DB快都具有断电保持功能2.2 FC功能建立说明::一、在右侧右击鼠标“右键”会弹出一个窗口如下,二、选择“Insert New Object”将会弹出下一级子窗口三选择“Function”并单击,弹出以下对话框在“Name”里写入需要的功能(FC),如FC1、FC2…………,范围为1……999都可以,在下面的“Symbolic Name”可以写入自己需要的注释。

点击“”就可以了。

3.1 DB数据块说明:DB 相当于数据M区,但在里面可以由用户编写自己所需要长度的数据,最大长度可以有65535个字节,且具有断电保持功能。

西门子S7-300教程

西门子S7-300教程

02
西门子s7-300编程
s7-300编程语言介绍
S7-300编程语言
LAD
STL
FBD
西门子的S7-300系列PLC主要 使用STEP 7编程软件进行编程, 支持多种编程语言,包括LAD (梯形图)、STL(语句表)和 FBD(功能块图)。这些语言各 有特点,适合不同的应用场景 和编程习惯。
LAD是最常见的PLC编程语言 ,它使用图形化方式表示逻辑 控制,直观易懂,适合初学者 使用。
在故障。
听诊法
通过听设备运行时的声音,判 断是否存在异常响动或杂音, 从而判断故障部位。
触摸法
通过触摸设备的表面、温度等 ,判断设备是否过热、振动等 异常现象。
测试法
通过使用专业的测试工具和软 件,对设备的各项性能进行测 试,从而确定故障的原因和部
位。
s7-300的日常维护
定期检查
定期对设备进行外观、电源、电缆等检查, 确保设备正常运行。
02
它具有强大的指令集和数据处理能力,能够处理复 杂的逻辑和控制任务。
03
S7-300具有高可靠性和长寿命,能够在恶劣的工业 环境中稳定运行。
s7-300的硬件组成
在此添加您的文本17字
S7-300的硬件组成包括中央处理单元(CPU)、信号模块、 通讯模块、功能模块和接口模块等。
在此添加您的文本16字
PLC与HMI的通讯
02
通过以太网协议,实现S7-300 PLC与HMI设备的实时数据交换
和监控。
PLC与上位机的通讯
03
通过以太网协议,实现S7-300 PLC与上位机的数据交换和远程
监控。
04
西门子s7-300故障诊断与维护

SIMATIC S7-300自动化系统模块数据商品说明书

SIMATIC S7-300自动化系统模块数据商品说明书

SIMATICS7-300Product Information on SIMATICS7-300 Automation System Module DataProduct InformationThis description forms part of the documentation package with the order number: S7-300 Automation System: 6ES7398-8FA10-8BA0.Legal information Warning notice systemThis manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below aregraded according to the degree of danger.indicates that death or severe personal injury will result if proper precautions are not taken.WARNINGindicates that death or severe personal injury may result if proper precautions are not taken.CAUTIONwith a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.CAUTIONwithout a safety alert symbol, indicates that property damage can result if proper precautions are not taken.NOTICEindicates that an unintended result or situation can occur if the corresponding information is not taken into account.If more than one degree of danger is present, the warning notice representing the highest degree of danger willbe used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.Qualified PersonnelThe product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.Proper use of Siemens productsNote the following:WARNINGSiemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation andmaintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed.TrademarksAll names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in thispublication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.Disclaimer of LiabilityWe have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.Siemens AG Industry Sector Postfach 48 4890026 NÜRNBERG A5E03007212-01 Ⓟ 05/2010 Copyright © Siemens AG 2010. Technical data subject to changeProduct Information on SIMATIC S7-300 Automation System Module Data PrefacePreface IntroductionThis product information amends the S7-300 automation system manual Module data, edition 08/2009.New power supply modulesThis product information applies to the following power supply modules: ● Power supply module PS 307; 2A (6ES7307-1BA01-0AA0) ● Power supply module PS 307; 5A (6ES7307-1EA01-0AA0) ● Power supply module PS 307; 10A (6ES7307-1KA02-0AA0)The power supply modules are characterized by their compact design and automatic voltage switching capacity. They are replacing the modules with order numbers 6ES7307-1BA00-0AA0, 6ES7307-1EA00-0AA0 and 6ES7307-1KA01-0AA0.Additional supportIf you have any questions relating to the products described in this product information andTechnical SupportYou can contact Technical Support for all Industry Automation products by means of thePrefaceService & Support on the InternetThere you will find:●Our Newsletter, which constantly provides you with the latest information about yourproducts.●The right documentation for you using our Service & Support search engine.●The bulletin board, a worldwide knowledge exchange for users and experts.●Your local contact for Automation & Drives in our contact database.●Information about on-site services, repairs, spare parts, and lots more.Product Information on SIMATIC S7-300 Automation System Module DataTable of contentsPreface (3)1 Power supply modules (7)1.1 Power supply module PS 307; 2 A; (6ES7307-1BA01-0AA0) (7)1.2 Power supply module PS 307; 5 A; (6ES7307-1EA01-0AA0) (10)1.3 Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0) (13)2 Dimensional drawings (17)2.1 Dimensional drawings of the power supply modules (17)Index (19)Product Information on SIMATIC S7-300 Automation System Module DataTable of contentsProduct Information on SIMATIC S7-300 Automation System Module DataPower supply modules 1 1.1Power supply module PS 307; 2 A; (6ES7307-1BA01-0AA0)Order number6ES7307-1BA01-0AA0PropertiesProperties of the PS 307; 2 A power supply module:●Output current 2 A●Output voltage 24 VDC; short circuit-proof, open circuit-proof●Connection to singlephase AC mains(rated input voltage 120/230 VAC, 50/60 Hz)●Safety isolation to EN 60 950●May be used as load power supplyProduct Information on SIMATIC S7-300 Automation System Module Data1.1 Power supply module PS 307; 2 A; (6ES7307-1BA01-0AA0)Product Information on SIMATIC S7-300 Automation System Module DataWiring diagram of PS 307; 2 A① Display for "Output voltage DC 24 V present" ② 24 VDC On/Off switch③ Mains and protective conductor terminals ④ Terminals for 24 VDC output voltage ⑤Strain-reliefBlock diagram PS 307; 2 A1/ / 0Figure 1-1Block diagram of the PS 307; 2 A power supply module1.1 Power supply module PS 307; 2 A; (6ES7307-1BA01-0AA0)Product Information on SIMATIC S7-300 Automation System Module Data Line protectionThe mains supply of the PS 307; 2 A power supply module should be protected with a miniature circuit-breaker (for example Siemens 5SN1 series) of the following rating: ● Rated current at 230 VAC: 3 A ● Tripping characteristics (type): C.Reaction to atypical operating conditionsTable 1- 1Reaction to atypical operating conditions of the PS 307; 2 A power supply moduleIf ...... then ... DisplayDC 24 V the output circuit is overloaded: ∙ I > 2.6 A (dynamic) ∙ 2 A < I ≤ 2.6 A (static)Voltage dip, automatic voltage recovery Voltage drop, reduction of service lifeflashes short-circuit at the output Output voltage 0 V; automatic voltage recovery after short-circuit is eliminated off overvoltage on primary side risk of destruction- undervoltage on primary sideAutomatic shutdown; automatic voltage recoveryoffTechnical specifications of PS 307; 2 A (6ES7307-1BA01-0AA0)Technical specifications Dimensions and weightDimensions W x H x D (mm) 40 x 125 x 120 Weightca. 400 gInput parameters Input voltage ∙ Rated value120/230 VAC (automatic switching) Mains frequency ∙ Rated value ∙ Permitted range50 Hz or 60 Hz 47 Hz to 63 Hz Rated input current ∙ at 230 V ∙ at 120 V0.5 A 0.9 A Inrush current (at 25 °C) 22 A I 2t (at inrush current) 1 A 2sOutput parameters Output voltage ∙ Rated value ∙ Permitted range ∙ Rampup time24 VDC24 V ± 3 %, open circuit-proof max. 2.5 sOutput current ∙ Rated value2 A, parallel wiring is available1.2 Power supply module PS 307; 5 A; (6ES7307-1EA01-0AA0)Product Information on SIMATIC S7-300 Automation System Module DataTechnical specifications Short-circuit protectionelectronic, non-latching 1.1 to 1.3 x I N Residual ripple max. 150 mV ppCharacteristicsSafety class to IEC 536 (DIN VDE 0106, Part 1) I, with protective conductor Isolation rating∙ Rated isolation voltage (24 V to L1) ∙ Test voltageAC 250 V DC 4200 V Safety isolationSELV circuit Buffering of power supply failure (at 93 V or 187 V) ∙ Repeat rateMin. 20 ms min 1 s Efficiency84 % Power consumption 57 W Power loss typ. 9 W Diagnostics"Output voltage present" displayyes, green LED1.2 Power supply module PS 307; 5 A; (6ES7307-1EA01-0AA0)Order number6ES7307-1EA01-0AA0PropertiesProperties of the PS 307; 5 A power supply module: ● Output current 5 A● Output voltage 24 VDC; short circuit-proof, open circuit-proof ● Connection to singlephase AC mains (rated input voltage 120/230 VAC, 50/60 Hz) ● Safety isolation to EN 60 950 ● May be used as load power supply1.2 Power supply module PS 307; 5 A; (6ES7307-1EA01-0AA0)Block diagram of PS 307; 5 A①Display for "Output voltage DC 24 V present" ② Terminals for 24 VDC output voltage ③ Strain-relief④ Mains and protective conductor terminals ⑤24 VDC On/Off switchBlock diagram PS 307; 5 A1/ / 0Figure 1-2Block diagram of the PS 307; 5 A power supply module1.2 Power supply module PS 307; 5 A; (6ES7307-1EA01-0AA0)Line protectionThe mains supplies of the PS 307; 5 A power supply module should be protected with aminiature circuit-breaker (for example Siemens 5SN1 series) of the following rating:●Rated current at 230 VAC: 6 A●Tripping characteristics (type): C.Reaction to atypical operating conditionsTable 1- 2 Reaction to atypical operating conditions of the PS 307; 5 A power supply moduleTechnical specifications of PS 307; 5 A (6ES7307-1EA01-0AA0)Technical specificationsDimensions and weightDimensions W x H x D (mm) 60 x 125 x 120Weight ca. 600 gInput parametersInput voltage∙Rated value 120/230 VAC (automatic switching)Mains frequency∙Rated value∙Permitted range 50 Hz or 60 Hz 47 Hz to 63 HzRated input current∙at 120 V ∙at 230 V 2.3 A 1.2 AInrush current (at 25 °C) 20 AI2t (at inrush current) 1.2 A2s Output parametersOutput voltage∙Rated value∙Permitted range 24 VDC24 V ± 3 %, open circuit-proof∙Rampup time max. 2.5 sOutput current∙Rated value 5 A, parallel wiring is available1.3 Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0) Technical specificationsShort-circuit protection electronic, non-latching1.1 to 1.3 x I NResidual ripple max. 150 mV ppCharacteristicsSafety class to IEC 536 (DIN VDE 0106, Part 1) I, with protective conductorIsolation rating∙Rated isolation voltage (24 V to L1) 250 VAC∙Test voltage 4200 VDCSafety isolation SELV circuitBuffering of power supply failure (at 93 V or 187 V) ∙Repeat rate Min. 20 ms min 1 sEfficiency 87 %Power consumption 138 WPower loss typ. 18 WDiagnostics"Output voltage present" display yes, green LED1.3Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0)Order number6ES7307-1KA02-0AA0PropertiesProperties of the PS 307; 10 A power supply module:●Output current 10 A●Output voltage 24 VDC; short circuit-proof, open circuit-proof●Connection to singlephase AC mains(rated input voltage 120/230 VAC, 50/60 Hz)●Safety isolation to EN 60 950●May be used as load power supply1.3 Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0)Block diagram of PS 307; 10 A① Display for "Output voltage DC 24 V present" ② Terminals for 24 VDC output voltage ③ Strain-relief④Mains and protective conductor terminals ⑤24 VDC On/Off switchBlock diagram PS 307; 10 A1/ / 0Figure 1-3Block diagram of the PS 307; 10 A power supply module1.3 Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0)Line protectionThe mains supplies of the PS 307;10 A power supply module should be protected with aminiature circuit-breaker (for example Siemens 5SN1 series) of the following rating:●Rated current at 230 VAC: 10 A●Tripping characteristics (type): C.Reaction to atypical operating conditionsTable 1- 3 Reaction to atypical operating conditions of the PS 307; 10 A power supply moduleTechnical specifications of PS 307; 10 A (6ES7 307-1KA02-0AA0)Technical specificationsDimensions and weightDimensions W x H x D (mm) 80 x 125 x 120Weight 800 gInput parametersInput voltage∙Rated value 120/230 VAC (automatic switching)Mains frequency∙Rated value∙Permitted range 50 Hz or 60 Hz 47 Hz to 63 HzRated input current∙at 230 V ∙at 120 V 1.9 A 4.2 AInrush current (at 25 °C) 55 AI2t (at inrush current) 3.3 A2s Output parametersOutput voltage∙Rated value∙Permitted range ∙Rampup time 24 VDC24 V ± 3 %, open circuit-proof max. 2.5 sOutput current∙Rated value 10 A, parallel wiring is available1.3 Power supply module PS 307; 10 A; (6ES7307-1KA02-0AA0)Technical specificationsShort-circuit protection electronic, non-latching1.1 to 1.3 x I NResidual ripple max. 150 mV pp CharacteristicsSafety class to IEC 536 (DIN VDE 0106, Part 1) I, with protective conductor Isolation rating∙Rated isolation voltage (24 V to L1) ∙Test voltage AC 250 V DC 4200 VSafety isolation SELV circuitBuffering of power supply failure (at 93 V or 187 V) ∙Repeat rate Min. 20 ms min 1 sEfficiency 90 %Power consumption 267 WPower loss typ. 27 W Diagnostics"Output voltage present" display yes, green LEDDimensional drawings 2 2.1Dimensional drawings of the power supply modulesIntroductionThis appendix contains the dimensional drawings of the most important components of anS7-300. The specified dimensions are required to determine the dimensions of an S7-300configuration. You need to take the dimensions of an S7-300 configuration into accountwhen installing an S7-300 in cabinets, contact chambers, etc.PS 307; 2 A (6ES7307-1BA01-0AA0)The figure below shows the dimensional drawing of the PS 307; 2 A power supply module.Dimensional drawings2.1 Dimensional drawings of the power supply modulesPS 307; 5A (6ES7307-1EA01-0AA0)The figure below shows the dimensional drawing of the PS 307; 5 A power supply module.PS 307; 10A (6ES7307-1KA02-0AA0)The figure below shows the dimensional drawing of the PS 307; 10 A power supply module.IndexDDimensional drawingPS 307 10 A, 18PS 307 2 A, 17PS 307 5 A, 18IInternetService & Support, 4OOrder number6ES7307-1BA01-0AA0, 76ES7307-1EA01-0AA0, 106ES7307-1KA02-0AA0, 13PPower supply modulePS 307 10 A, 13PS 307 2 A, 7PS 307 5 A, 10PS 307 10 ASchematic circuit diagram, 14 Technical specifications, 15Wiring diagram, 14PS 307 2 ASchematic circuit diagram, 8Technical specifications, 9Wiring diagram, 8PS 307 5 ASchematic circuit diagram, 11 Technical specifications, 12Wiring diagram, 11SService & Support, 4 TTechnical Support, 3Index。

西门子S7——300系列PLC系统配置模块的选择大全

西门子S7——300系列PLC系统配置模块的选择大全

西门⼦S7——300系列PLC系统配置模块的选择⼤全西门⼦S7——300系列PLC系统配置模块的选择⼤全电源模板6ES7 307-1BA00-0AA0 电源模块(2A) 1,240.306ES7 307-1EA00-0AA0 电源模块(5A) 1,645.306ES7 307-1KA01-0AA0 电源模块(10A) 2,126.23CPU6ES7 315-6FF01-0AB0 CPU315F-2DP,192K内存35,271.646ES7 317-2AJ10-0AB0 CPU317-2DP,512K内存34,284.786ES7 317-2EJ10-0AB0 CPU317-2PN/DP,512K内存38,943.366ES7 317-6FF00-0AB0 CPU317F-2DP,512K内存55,757.126ES7 317-6TJ10-0AB0 CPU317T-2DP技术型,512K内存47,342.54内存卡6ES7 953-8LF11-0AA0 SIMATIC Micro内存卡64kByte(MMC) 429.306ES7 953-8LG11-0AA0 SIMATIC Micro内存卡128KByte(MMC) 858.596ES7 953-8LJ11-0AA0 SIMATIC Micro内存卡512KByte(MMC) 1,961.326ES7 953-8LL11-0AA0 SIMATIC Micro内存卡2MByte(MMC) 2,815.206ES7 953-8LM11-0AA0 SIMATIC Micro内存卡4MByte(MMC) 3,428.486ES7 953-8LP11-0AA0 SIMATIC Micro内存卡8MByte(MMC) 4,292.976ES7 951-0KD00-0AA0 FEPROM 内存卡16K 1,344.906ES7 951-0KE00-0AA0 FEPROM 内存卡32K 2,134.496ES7 951-0KF00-0AA0 FEPROM 内存卡64K 2,828.646ES7 951-0KG00-0AA0 FEPROM 内存卡128K 4,268.996ES7 971-1AA00-0AA0 锂电池3.6V/0.95AH 141.53开关量模板6ES7 321-1BH02-0AA0 开⼊模块(16点,24VDC)1,686.526ES7 321-1FF01-0AA0 开⼊模块(8点,120/230V AC)1,309.126ES7 321-1FH00-0AA0 开⼊模块(16点,120/230VAC)2,170.076ES7 322-1BH01-0AA0 开出模块(16点,24VDC)2,346.986ES7 322-5FF00-0AB0 开出模块(8点,120V/230VAC,独⽴接点)3,007.44 6ES7 322-1HF01-0AA0 开出模块(8点,继电器,2A)1,627.556ES7 322-1HF10-0AA0 开出模块(8点,继电器,5A,独⽴接点)2,004.966ES7 322-1HH01-0AA0 开出模块(16点,继电器) 3,490.996ES7 322-5HF00-0AB0 开出模块(8点,继电器,5A,故障保护)2,229.046ES7 322-1FH00-0AA0 开出模块(16点,120V/230VAC)3,585.346ES7 323-1BH01-0AA0 8点输⼊,24VDC;8点输出,24VDC模块2,571.06 6ES7 323-1BL00-0AA0 16点输⼊,24VDC;16点输出,24VDC模块4,387.32 模拟量模板6ES7 331-7KF02-0AB0 模拟量输⼊模块(8路,多种信号) 6,498.426ES7 331-7KB02-0AB0 模拟量输⼊模块(2路,多种信号) 2,028.556ES7 331-7NF00-0AB0 模拟量输⼊模块(8路,15位精度) 6,085.646ES7 331-7HF01-0AB0 模拟量输⼊模块(8路,14位精度,快速) 7,099.916ES7 331-1KF01-0AB0 模拟量输⼊模块(8路, 13位精度) 4,446.296ES7 331-7PF01-0AB0 8路模拟量输⼊,16位,热电阻7,760.376ES7 331-7PF11-0AB0 8路模拟量输⼊,16位,热电偶7,760.376ES7 332-5HD01-0AB0 模拟输出模块(4路) 5,413.396ES7 332-5HB01-0AB0 模拟输出模块(2路) 3,384.846ES7 332-5HF00-0AB0 模拟输出模块(8路) 10,107.356ES7 332-7ND02-0AB0 模拟量输出模块(4路,15位精度) 6,698.926ES7 334-0KE00-0AB0 模拟量输⼊(4路RTD)/模拟量输出(2路)3,986.33 6ES7 334-0CE01-0AA0 模拟量输⼊(4路)/模拟量输出(2路)3,986.33功能模板6ES7 350-1AH03-0AE0 FM350-1 计数器功能模块4,316.566ES7 350-2AH00-0AE0 FM350-2 计数器功能模块9,942.236ES7 351-1AH01-0AE0 FM351 定位功能模块7,748.576ES7 352-1AH01-0AE0 FM352 电⼦凸轮控制器8,167.256ES7 352-1AH00-8BG0 组态软件包1,648.596ES7353-1AH01-0AE0 步进电机定位模块7,275.746ES7 354-1AH01-0AE0 FM354 伺服电机定位模块6ES7 355-0VH10-0AE0 FM355C 闭环控制模块10,590.906ES7 355-0VH00-8BA0 组态软件包6ES7 355-1VH10-0AE0 FM355S 闭环控制系统9,163.846ES7 355-2CH00-0AE0 FM355-2C 闭环控制模块9,777.126ES7 355-2SH00-0AE0 FM355-2S 闭环控制模块8,468.006ES7 357-4AH01-0AE0 FM357-2多轴定位模块6ES7 357-4AH03-3AE0 FM357-2L 系统固件单独许可证6ES7 357-4BH03-3AE0 FM357-2XL 系统固件单独许可证6ES7 338-4BC01-0AB0 SM338绝对位置输⼊模块3,184.346ES7 352-5AH00-0AE0 FM352-5⾼速布尔处理器10,429.326ES7 352-5AH00-7XG0 FM352-5功能软件包5,413.39通讯模板6ES7 340-1AH01-0AE0 CP340 通讯处理器(RS232)4,316.566ES7 340-1BH02-0AE0 CP340 通讯处理器(20mA/TTY)5,725.926ES7 340-1CH02-0AE0 CP340 通讯处理器(RS485/RS422)5,725.92 6ES7 341-1AH01-0AE0 CP341 通讯处理器(RS232)8,680.296ES7 341-1BH01-0AE0 CP341 通讯处理器(20mA/TTY)9,328.956ES7 341-1CH01-0AE0 CP341 通讯处理器(RS485/RS422)9,328.95 6ES7 341-1AH00-8BA0 CP341 通讯模块配置软件包1,648.596ES7 870-1AA01-0Y A0 可装载驱动MODBUS RTU 主站14,874.876ES7 870-1AB01-0Y A0 可装载驱动MODBUS RTU 从站6.8 14,874.87 6GK7 342-5DA02-0XE0 CP342-5通讯模块7931.556GK7 342-5DF00-0XE0 CP342-5 光纤通讯模块9885.706GK7 343-5FA01-0XE0 CP343-5通讯模块10345.506GK7 343-1EX11-0XE0 CP343-1 以太⽹通讯模块15,748.15。

S7-300模块接线图

S7-300模块接线图

S7-300 通用型模拟量输入扩展模块(SM331)技术规范及接线图一、S7-300 通用型模拟量输入扩展模块(SM331)技术规范1、SM331技术规范1技术规范SM331型号6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0图片模拟量输入特性模拟量输入通道8模拟量输入,9/12/14位分辨率8模拟量输入,14位分辨率,用于等时模式下运行8模拟量输入,13位分辨率2模拟量输入,9/12/14位分辨率• 电阻测量模拟量输入点数 4 8 1所需前连接器20 针20 针40 针20 针时钟同步• 时钟同步运行否支持否否测量范围电压输入范围• 0 至+10 V• 1 至 +5 V• 1 至 +10 V• -1 V 至 +1 V• -10 V 至 +10 V • -2.5 V 至 +2.5 V • -250 mV 至 +250 mV • -5 V 至 +5 V 支持支持支持支持支持支持支持支持支持支持支持支持支持否支持支持否否支持支持支持支持支持支持支持2、SM331技术规范2图片接线图6ES7331-1KF01-0AA0 40针6ES7331-7HF01-0AB0 20针6ES7331-7KB02-0AB0 20针6ES7331-7KF02-0AB0 20针6ES7331-7NF00-0AB0 40针6ES7331-7NF10-0AB0 40针6ES7331-7PF01-0AB0 40针6ES7331-7PF11-0AB0 40针。

S7-300学习资料(视频祥解)

S7-300学习资料(视频祥解)

S7-300学习笔记第一讲:S7-300简介一、标准型S7-300的硬件结构1.S7-300为标准模块式结构,各种模块相互独立,并安装在固定的机架(导轨)上,构成一个完整的PLC应用系统。

2.第一槽为电源模块,第二槽为CPU模块,第三槽为通信模。

3.300电源模块(PS)可用其它开关电源代替,而400必须选用原装模块二、S7-300 CPU模块1.CPU模块分类1)300PLC可分为紧凑型.标准型.革新型.户外型.故障安全型和特种型CPU2)C表示紧凑型.F故障安全型T表示特种型2.S7-300 CPU的主要特点3.S7-300 CPU状态故障显示1)SF(红色):系统出错/故障指示灯,硬件或软件出错时亮2)BATF(红色) :电池故障指示灯,没电或没有装入电池时亮.314和316有.故障时不影响CPU工作3)DC5V(绿色) :5V电源指示灯,总线5V电源正常时常亮4)FRCE(黄色) :强制作业有效指示灯,有强制时亮5)RUN(绿色) :运行指示灯.处于RUN时亮,在STARTUP(启动)时以2HZ闪烁,在HOLD(暂停)时0.5HZ闪烁6)STOP(黄色) :CPU处于STARTUP. HOLD.时常亮,在存储器复位时0.5HZ闪.在存储器置位时以2HZ闪烁.7)BUS DF(BF)(红色) :总线出错时亮,(只适用于带有DP接口的CPU).8)SF DP:接口错误指示灯,DP接口故障时亮三、S7-300 PLC功能1.高速的指令处理:0.1-0.6us的指令处理时间2.人机界面(HMI):人机界面集成在S7-300操作系统内3.诊断功能:CPU的智能化的诊断系统可连续监控系统的功能是否正常,记录错误和特殊的系统事件4.口令保护:多级口令保护可以使用户高度、有效的保护其技术机密,防止未经允许的复制和修改四、S7-300 模块PS电源模块、IM接口模块(360发送361接收)、FM功能模块、SM信号模块。

西门子S7-300模块化结构

西门子S7-300模块化结构

西门子S7-300模块化结构
一、S7-300/400 模块化结构与小型plc(如西门子S7-200)不同,大中型PLC 最大的特点就是采用模块化控制系统,来满足中等或高性能要求的应用。

在大中型PLC 系统中,各种单独的模块之间可进行广泛组合以用于扩展,由于点数基本上不受太多的限制,其灵活性就非常高。

基本的模块化硬件结构结构包括机架、电源、处理器CPU、输入输出I/O 模块、编程或通讯用接口,图
1 表示了一个模块化控制器是如何由模块化硬件部件一一组成的。

图1 模块化控制器的组成部分
其中机架是用来安装处理器和I/O 模块、特殊模块的,所有模块都可以很容易地沿着导轨插入到机架。

不同类型的PLC 系统其机架槽数不太一样,可以互联的机架数也不尽相同。

大中型PLC 系统在配置时,其机架数可以有很多,机架之间的关系可以用图2 来表示。

图2 机架网络
二、西门子S7-300 PLC 1、模块化结构S7-300 为节省空间的模块化结构设计,可以适配用户现有的各种机械控制任务,不需要考虑槽位规则。

在运行时,无需风扇。

除模块外,只需要DIN 标准的导轨,就可以将模块旋转到位,安装在导轨上并用螺钉紧固。

这种结构形式非常牢固并且有很高的电磁兼容性。

S7- 300 的背板总线集成在模块上,通过将模块插入到总线连接器进行装配。

如图
3 所示为S7-300 模块化结构安装现场。

tips:感谢大家的阅读,本文由我司收集整编。

仅供参阅!。

s7-300模块式PLC资料

s7-300模块式PLC资料

S7 300 教程S7-300/400 的基本结构S7-300/400 属于模块式 PLC ,主要由机架、CPU 模块、信号模块、功能模块、接口模块、通信处理器、电源模块和编程设备组成。

按 钮选择开关 限位开关 电 源源图 1-1 PLC 控制系统示意图PLC 的主要生产厂家:德国的西门子(Siemens)公司,美国 Rockwell公司所属的 AB 公司,GE-Fanuc 公司,法国的施耐德(Schneider)公司,日本的三菱和欧姆龙(OMRON)公司。

西门子自动化与驱动集团的中文网站: 。

在该网站主页点击―中文下载目录‖、―英文下载资料‖或―软件下载 目录‖,进入―下载中心‖后,可以下载各种工控产品的中英文说明 书、使用手册、产品介绍和一些软件。

如果需要更多的资料和软件,可以访问西门子在德国的网站,网 址为 http://www.ad.siemens.de/。

点击―English ‖将语言由德文改为英文,点击―Service & Support ‖,在―Document type ‖下面点击―Manual ‖,在―Please Type Your Question ‖下面的方框内输入要搜索的手册的关 键字,例如―CP 5511‖,按―GO ‖按钮,就会列出与 CP 5511 有关 的手册。

点击感兴趣的手册,在出现的画面中点击―Download ‖,可 以下载该手册。

PLC 的工作过程I0.0I0.1I0.0& I0.1Q4.0Q4.0I0.2I0.3I0.2I0.3Q4.1Q4.1>=1I0.4I0.4Q4.2Q4.2( a ) 与( b ) 或图1-2 基本逻辑运算( c ) 非1 0 0 1 0 11 1 1 1 1 1PLC 采用循环执行用户程序的方式。

OB1 是用于循环处理的组织块(主程序),它可以调用别的逻辑块,或被中断程序(组织块)中断。

在起动完成后,不断地循环调用OB1,在OB1 中可以调用其它逻辑块(FB, SFB, FC 或SFC)。

第2讲 S7-300常用信号模块

第2讲 S7-300常用信号模块

二、模拟量模块
模拟量输入模块精度
二、模拟量模块
模拟量输入模块SM331 2. 模拟量输入模块SM331 模拟量输入(简称模入(AI))模块SM331目 模拟量输入(简称模入(AI))模块SM331目 (AI))模块SM331 前有三种规格型号, 8AI×l2位模块、 前有三种规格型号,即8AI×l2位模块、 位模块 2AI×l2位模块和8AI×l6位模块。 2AI×l2位模块和8AI×l6位模块。 位模块和8AI 位模块
二、模拟量模块
SM331概述 (1) SM331概述 SM331主要由A/D转换部件、模拟切换开关、补偿电路、 SM331主要由A/D转换部件、模拟切换开关、补偿电路、 主要由A/D转换部件 恒流源、光电隔离部件、逻辑电路等组成。A/D转换部件是 恒流源、光电隔离部件、逻辑电路等组成。A/D转换部件是 模块的核心,其转换原理采用积分方法, 模块的核心,其转换原理采用积分方法,被测模拟量的精度 是所设定的积分时间的正函数,也即积分时间越长,被测值 是所设定的积分时间的正函数,也即积分时间越长, 的精度越高。SM331可选四档积分时间: ms、 ms、 的精度越高。SM331可选四档积分时间:2.5 ms、16.7 ms、20 可选四档积分时间 ms和 ms,相对应的以位表示的精度为8 12、12和14。 ms和l00 ms,相对应的以位表示的精度为8、12、12和14。
二、模拟量模块
SM33l与传感器 与传感器、 (2) SM33l与传感器、变送器的连接 a、SM331与电压型传感器的连接 SM331与电压型传感器的连接
二、模拟量模块
SM331与 b、 SM331与2线电流变送器的连接
二、模拟量模块
c、SM331与4线电流变送器的连接 SM331与

第一讲 西门子S7-300简介

第一讲  西门子S7-300简介

350-1, FM 350-2计数器模板 351用于快速/慢速驱动的定位模板 353用于步进电机的定位模板 354用于侍服电机的定位模板 357-2定位和连续通道控制模板 338 超声波位置探测模板 338 SSI 位置探测模板 352电子凸轮控制器 352-5高速布尔运算处理器 355 PID模板 355-2温度PID控制模板

双机架接口模块IM365

IM365发送模块 IM365接收模块。 IM360:用于发送数据
X2 34 365 - 0BA01- 0AA0 365 - 0BA01- 0AA0 X2 34

多机架接口模块

IM361:用于接收数据
IM 360 SF DC 5V SF DC 5V IM 360
户外型CPU(三种): CPU 312 IFM CPU 314 IFM CPU 314(U 315F CPU 315F-2DP CPU 317F-2DP
特种型CPU(两种): CPU 317T-2DP CPU 317-2PN/DP
2、S7-300CPU的主要特性:
STOP:停机模式。在此模式下,CPU不执行用户程序,但 可以通过编程设备(如装有STEP 7的PG、装有STEP 7的计算机 等)从CPU中读出或修改用户程序。在此位置可以拔出钥 匙。 MRES:存储器复位模式。该位置不能 保持,当开关在此位置释放时将自动返回 到STOP位置。将钥匙从STOP模式切换到 MRES模式时,可复位存储器,使CPU回到 初始状态。
STOP(黄色):停止状态指示灯。CPU处于“STOP”或 “HOLD”或“Startup”状态时亮;在存储器复位时LED以0.5 Hz频率闪烁;在存储器置位时LED以2Hz频率闪烁。 BF(红色):总线出错指示灯(只适用于带 有DP接口的CPU)。出错时亮。

S7-300 的功能模块

S7-300 的功能模块

S7-300的功能模块1.计数器模块模块的计数器均为0〜32位或土31位加减计数器,可以判断脉冲的方向,模块给编码器供电。

达到比较值时发出中断。

可以2倍频和4倍频计数。

有集成的DI/DO oFM350-1是单通道计数器模块,可以检测最高达500kHz的脉冲,有连续计数、单向计数、循环计数3种工作模式。

FM350-2和CM35都是8通道智能型计数器模块。

2.位置控制与位置检测模块FM351双通道定位模块用于控制变级调速电动机或变频器。

FM353是步进电机定位模块。

FM354伺服电机定位模块。

FM357可以用于最多4个插补轴的协同定位。

FM352高速电子凸轮控制器,它有32个凸轮轨迹,13个集成的DO,采用增量式编码器或绝对式编码器。

SM338超声波传感器检测位置,无磨损、保护等级高、精度稳定不变。

3.闭环控制模块FM355闭环控制模块有4个闭环控制通道,有自优化温度控制算法和PID算法。

4.称重模块SIWAREXU称重模块是紧凑型电子称,测定料仓和贮斗的料位,对吊车载荷进行监控,对传送带载荷进行测量或对工业提升机、轧机超载进行安全防护等。

SIWAREXM称重模块是有校验能力的电子称重和配料单元,可以组成多料称系统,安装在易爆区域。

5.电源模块PS307电源模块将120/230伏交流电压转换为24V直流电压,为S7-300/400、传感器和执行器供电。

输出电流有2A、5A或10A3种。

电源模块安装在DIN导轨上的插槽1o^□0丄匸H匸]祜图2-17S7-300的浮动参考电位某些大型工厂(例如化工厂和发电厂)为了监视对地的短路电流,可能采用浮动参考电位,可以将M点与接地点之间的短接片去掉。

2.S7-400系列PLC的硬件组成模块的尺寸为25(宽)X290(高)X210(深)mm。

图2-182-15S7-400PLCPLCccEUEU图2-HS7-400的參机頤连挂集中式扩展方式适用于小型配置或一个控制柜中的系统。

3S7-300模拟量模块使用

3S7-300模拟量模块使用
输出范围为0 - 20 mA 和 4 - 20 mA的模拟值表示
3---更换量程卡
1 使用改锥,将量程模板从模拟量输入模板中松开。
3---更换量程卡
2 将量程模板(正确定位(1))插入模拟量输入模板中, 所选测量范围为指向模板(2)上标记点的测量范围。
4---参数设置
1 模拟量输入模块参数设置
模拟量输出模块设置电压输出范围是0-10V; 那么在PLC里任意给定一个在5-80HZ的频率值,模 拟量输出模拟值是多少?
2 任务分析
变频器每1mV对应的频率值=(80-5) / 1000 输出模块每1mV对应的模拟值=27648 / 1000
输出模块每1HZ对应的模拟值=27648 /(80-5) 在6-80HZ内的任意一个频率值X对应的输出模拟值Y 的关系是:
连接双线变送器至带隔离的模拟输入
5--接线 5-1传感器与模拟量输入的连 接1 按照接线图进行传感器与模拟量输入的连接。
连接从L+供电的双线变送器至带隔离的模拟输入
5--接线 5-1传感器与模拟量输入的连 接1 按照接线图进行传感器与模拟量输入的连接。
连接四线变送器至带隔离的模拟输入
5--接线 5-2连接负载 /执行器至模拟量输出
3 编程步骤:符号表编程。
6---应用举例 6-1 压力检测
4 编程步骤:FC1功能程序编写。
6---应用举例 6-1 压力检测
4 编程步骤:FC1功能程序编写。
6---应用举例 6-1 压力检测
4 编程步骤:FC1功能程序编写。
6---应用举例 6-1 压力检测
4 编程步骤:FC1功能程序编写。
Y=27648(X-5) / (80-5)
6--应用举例 6-2控制变频器的输出频 率3 编程步骤:符号表编写。

S7-300安全模块使用手册

S7-300安全模块使用手册

输入变量1、PASS_ON:通过安全程序把这个变量置为1,可以钝化该模块(注意:这个操作只能钝化整个模块不能对单个通道进行钝化)2、ACK_NEC:通过对这个变量进行操作来选择是手动对模块进行去钝还是模块自身自动去钝3、ACK_REI:当ACK_NEC为1时必须对这个变量进行操作模块才能去钝,也就是这个变量是手动去钝操作执行变量。

(只有在模块故障被排除后起作用,通信故障除外)4、IPAR_EN:对这个变量操作,来从新参数化DP标准从站或某个标准I/O设备输出变量1、PASS_OUT:状态为1时,说明该模块已被钝化(注意如果是通过变量PASS_ON进行模块钝化的,该变量的状态不会发生变化)2、QBAD:状态为1时说明模块中至少有一个通道检测到了错误3、ACK_REQ:状态为1时说明该模块故障已经排除,但并没对模块进行去钝操作4、IPAR_OK:状态为1时说明参数从传完成5、DIAG:模块附加的诊断信息6、QBAD_I_XX和QBAD_Q_XX:状态为1时说明当前输入或输出通道有错误。

1oo2该指令实现两个单通道传感器,具有差异分析相结合的1oo2评估。

输出Q被设置为1,如果被存储和IN2都等于1并且没有误差错误DISC_FLT输入IN1的信号状态。

如果一个或两个输入信号状态为0,输出Q设置为0号一旦:作为输入IN1和IN2的信号状态不同,差异时间DISCTIME开始。

如果一旦过了差异时间到期的两个输入信号状态很安静不同,检测到误差错误,并DISC_FLT设置为1(重新启动抑制)。

如果输入IN1和IN2之间的差异不再检测,误差错误被确认为根据ACK_NEC的参数分配:如果ACK_NEC = 0时,确认是自动的。

如果ACK_NEC = 1,则必须使用一个上升沿输入ACK来确认误差错误。

输出ACK_REQ = 1的信号做了一个用户确认在输入ACK需要确认误差错误(取消重新启动禁止)。

指令一旦不再检测到差异设置ACK_REQ = 1。

S7-300串口通讯模块CP340和CP341的区别

S7-300串口通讯模块CP340和CP341的区别
7
规格型号
CP340有4种型号,及支持协议:
。。(1)6ES7340-1AH00-0AE0S7300RS232C串行通讯模板ASCII,3964R,USS
。。(2)6ES7340-1AH01-0AE0S7300RS232C串行通讯模板ASCII,3964R,printer,USS
。。(3)6ES7340-1BH00-0AE0S730020mATTY串行通讯模板ASCII,3964R,printer,USS
我们在有些场合,为了节约成本,用过这样的方案:用一个CPU224XP作为MODBUS通讯设备(主/从都支持),而用另外一个通讯口与S7-300的PLC进行连接做MPI从站,S7-300用“X_GET”和“X_PUT”向S7-200中读写数据,使用的效果看,既稳定编程也简单,最重要的是省钱,但从机柜设计和接线上来说,没CP340简单。
接收程序是调用FB7来实现的,由于CP341可以处理接收程序的细节部分.因此对于设计者来说只需要进行简单的设计就可以实现数据的接收。
对于Modbus多从站的通信(CP341带硬件狗为主站),编程时尤为需要注意,对于地址和站号等的轮询需要合理安排,否则会引起从站间的数据混乱。同时注意读上来的高低字节问题。
。。(4)6ES7340-1CH00-0AE0S7300RS422/485串行通讯模板ASCII,3964R,printer,USS
CP341有3种型号,及支持协议:
。。(1)6ES7341-1AH0x-0AE0S7300RS232C串行通讯模板RK512,ASCII,3964(R),ModbusMaster/Slave(RTU格式),DataHighway(DF1协议),USS
也有人这么用:我一般都用CP340来实现MODBUS的通信:

S7-300(FC105,FB41,FB43,FC106)功能块的使用

S7-300(FC105,FB41,FB43,FC106)功能块的使用

FC105的使用----FC105是处理模拟量(1~5V、4~20MA等常规信号)输入的功能块:打开Libraries\standard library\Ti-S7 Converting Blocks\fc105,将其调入OB1中,给各个管脚输入地址;如下图:其中管脚的定义如下:IN---------模拟量模块的输入通道地址,在硬件组态时分配;HI_LIM-----现场信号的最大量程值;LO_LIM-----现场信号的最小量程值;BIPOLAR—---极性设置,如果现场信号为+10V~-10V(有极性信号),则设置为1,如果现场信号为4MA~20MA(无极性信号),则设置为0;RET_VAL----FC105功能块的故障字,可存放在一个字里面。

如:MW50;OUT--------现场信号值(带工程量单位);信号类型是实数,所以要用MD200来存放;热电偶、热电阻信号的处理,该类信号实际值是通道整数值的1/10;FB41 PID控制模块的使用----PID模块是进行模拟量控制的模块,可以完成恒压、恒温等控制功能:打开Libraries\standard library\PID Control block\FB41,将其调入OB1中,首先分配背景数据块DB41,再给各个管脚输入地址;如下图:脉冲输出模块FB43,该模块是将模拟量转换成比率的脉冲输出。

Libraries\standard library\PID Control block\FB43,将其调入OB1中,首先分配背景数据块DB43,再给各个管脚输入地址;如下图:通道地址输入PID的输出通道. 如下图:使用FC106模块如果单独控制变量输出通道,可使用FC106模块:FC106是处理模拟量(1~5V、4~20MA 等常规信号)输出的功能块,打开Libraries\standard library\Ti-S7 Converting Blocks\fc106,将其调入OB1中,给各个管脚输入地址;如下图:。

s7-300 PLC 模块介绍

s7-300 PLC 模块介绍
n节约空间
n CPU宽度缩短一半,仅为 40mm
全新的 S7-300 家族
SIMATIC S7-300
A&D AS, 07/2003, Chart 4 © Siemens AG 2003 - Subject to change without prior notice
•标准CPU与第一代S7-300 CPU相比,具有更短的指令执行周期。在最高 端的317平台上,最快的指令执行时间仅需要50ns,已经可以满足一般 运动控制的要求
8
SIMATIC S7-300
产品定位 CThPeUsCPUs 信号模板(SM) 接口模板(IM) 通讯处理器(CP) 功能模块(FM) 工程工具(STEP7)
S7-300 紧凑型CPU-性能参数
Automation and Drives
工作内存 / 指令
扩展能力 • 机架 • 每机架模块数
CPU 312C 16K / 5K
A&D AS, 07/2003, Chart 3 © Siemens AG 2003 - Subject to change without prior notice
新一代S7-300 CPU可以分为两大类,标准型CPU和紧凑型CPU
3
SIMATIC S7-300
产品定位 CCPPUUss 信号模板(SM) 接口模板(IM) 通讯处理器(CP) 功能模块(FM) 工程工具(STEP7)
S7-300 标准CPU - 亮点
Automation and Drives
n更短的指令执行周期
n 最快指令执行时间仅50ns
n降低工程费用
n 高效的工程工具STEP7
n 模块化的组态编程
n降低维护费用

S7-300 通用型模拟量输入扩展模块(SM331)技术规范及接线图

S7-300  通用型模拟量输入扩展模块(SM331)技术规范及接线图
15/15/15/15位,
双极性:15+VZ/
15+VZ/15+VZ/15+VZ
支持;
23/72/83/95ms
10ms(4通道模式)95/
83/72/23ms
(8通道模式)
400/60/50Hz,400,60,50Hz组合
连接的传感元件
?用于电流测量,2线制测量变送器
?用于电流测量,4线制测量变送器
2、SM331技术规范2
技术规范
SM331
型号
6ES7331-7PF00-0AB0
6ES7331-7PF10-0AB0
6ES7331-7NF00-0AB0
6ES7331-7NF10-0AB0
图片
模拟量输入特性
模拟量输入通道?
8点模拟量输入,用于热电阻
8点模拟量输入,用于热电偶
8点模拟量输入,增强型16位分辨率
8点模拟量输入,增强型16位分辨率,4通道模式
?电阻测量模拟量输入点数
8
所需前连接器
40针
40针
40针
40针
时钟同步
?时钟同步运行




测量范围
电压输入范围
?1至+5V
?-10V至+10V
?-5V至+5V
支持
支持
支持
支持
支持
支持
电流输入范围
?0至20mA
?-20至20mA
?4至20mA
支持
支持
支持
图片
模拟量输入特性
模拟量输入通道?
8模拟量输入,9/12/14位分辨率
8模拟量输入,14位分辨率,用于等时模式下运行
相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

40mA
20针
8
1000m
600m
40x125x120
6ES7 323-1BH01-0AA0
数字量输入/输出模块 SM323/SM327
6ES7
323-1BL00-0AA0
6ES7 327-1BH00-0AB0
24VDC 24VDC 24VDC
40mA 80mA 60mA
20针 40针 20针
88 16 16 88
900mA 256KB 8MB
4 8 RS485 RS485
40x125x130
CPU317-2DP
6ES7-317-2AJ10-0AB0 24VDC 20.4~28.8
850mA 512KB 8MB
4 8 RS485 RS485
80x125x130
CPU315-2PN/DP(V3.1) 6ES7 315-2EH14-0AB0 24VDC 20.4~28.8 150mA 750mA 348KB 8MB
2
4
8
RS485
RS422 RS485(X.27)
120x125x130
CPU 314C-2DP
6ES7 314-6CG03-0ABO 24VDC 20.4~28.8 150mA 1000mA 96KB 8MB 24 16 4 2 4 8 RS485 RS485
120x125x130
CPU312(V3.0)
40x125x120
6ES7 322-5HF00-0AB0 24VDC/230VAC
100mA
40针
8
1000m
600m
40x125x120
6ES7 322-1HH01-0AA0 120VDC/230VAC
100mA
20针
8
1000m
600m
40x125x120
多种前连接器
6ES7 322-1HF00-0AA0 24VDC
1 8 RS485
80x125x130
CPU 313C
6ES7 313-5BF03-0AB0 24VDC 20.4~28.8 150mA 700mA 64KB 8MB 24 16 4 2 4 8 RS485
120x125x130
CPU 313C-2PtP
6ES7 313-6BF03-0AB0 24VDC 20.4~28.8 100mA 700mA 64KB 8MB 16 16
模拟量输入-安全集成 SM336F
6ES7
336-1HE00-0AB0
6ES7 331-7RD00-0AB0
Ex模拟量输入/输出模 块
6ES7
331-7SF00-0AB0
6ES7 332-5RD00-0AB0
负载电压/额定值
24VDC 24VDC
24VDC 24VDC 24VDC
24VDC 24VDC 24VDC 24VDC 24VDC 24VDC 24VDC
6ES7 332-5HD01-0AB0 模拟量输出模块SM332
6ES7 332-5HF00-0AB0
6ES7 332-7ND02-0AB0
模拟量输入/输出模块 6ES7 334-0CE01-0AA0
SM334
6ES7 334-0KE00-0AB0
快速模拟量输入输出模 块SM335
6ES7
335-7HG01-0AB0
备注
多种前连接器 多种前连接器 多种前连接器
多种前连接器
多种前连接器 多种前连接器
型号
订货号
数字量
电缆长度
负载电压/额定值 电流消耗 前连接器
输入 输出 屏蔽 非屏蔽
尺寸 WxHxD(mm)
备注
6ES7 322-1FF01-0AA0 230V;120/230VAC
2mA
20针
8
1000m
600m
40x125x117
110mA
20针
16
6ES7 321-1BP00-0AA0 24VDC
100mA 电缆,端子板 64
6ES7 321-7BH01-0AB0 24VDC 数字量输入模块SM321
6ES7 321-1CH00-0AA0 24V-48VDC/AC
130mA 100mA
20针
16
40针
16
6ES7 321-1CH20-0AA0 48V-125VDC
24VDC
24VDC
24VDC 24VDC 24VDC
S7-300 模拟量模块
电流消耗
4 8 RS485 以太网RJ45
40x125x130
CPU315-2PN/DP
6ES7 315-2EH13-0AB0 24VDC 20.4~28.8 100mA 650mA 256KB 8MB
4 8 RS485 以太网
80x125x130
CPU317-2PN/DP(V3.1) 6ES7 317-2EK14-0AB0 24VDC 20.4~28.8 150mA 750mA 1MB 8MB
40针8Biblioteka 6ES7 322-1BH01-0AA0 24VDC
80mA
20针
16
6ES7 322-1BH10-0AA0 24VDC
70mA
20针
16
6ES7 322-1BL00-0AA0 24VDC
110mA
40针
32
6ES7 322-8BF00-0AB0 24VDC
70mA
20针
8
数字量输出模块SM322 6ES7 322-5GH00-0AB0 24VDC;24/48VDC
4 8 RS485 RS485
RJ45 120x125x130
注:
CPU315F-2DP,CPU317F-2DP,CPU315F-2PN/DP,CPU315F-2PN/DP,CPU319F-2PN/DP为故障安全型CPU,各基于其相应的标准型CPU
CPU315T-2DP,CPU317T-2DP为运动控制型CPU,各基于其相应的标准型CPU
4
8
RS485
RS422 RS485(X.27)
120x125x130
CPU 313-2DP
6ES7 313-6CF03-0AB0 24VDC 20.4~28.8 100mA 900mA 64KB 8MB 16 16
4 8 RS485 RS485
120x125x130
CPU 314C-2PtP
6ES7 314-6BG03-0AB0 24VDC 20.4~28.8 150mA 800mA 96KB 8MB 24 16 4
S7-300 CPU模块
型号
订货号
额定电压 额定值 范围
电流消耗 存储器 数字量 模拟量 组态 空载 最大 内置 MMC 输入 输出 输入 输出 机架 模块 一
接口 二
尺寸 三 WxHxD(mm)
CPU 312C
6ES7 312-5BE03-0AB0 24VDC 20.4~28.8 60mA 500mA 32KB 4MB 10 6
6ES7 322-5FF00-0AB0 230V;120/230VAC
100mA
40针
8
1000m
600m
40x125x120
6ES7 322-1FH00-0AA0 230V;120/230VAC
200mA
20针
16 1000m
600m
40x125x120
6ES7 322-1FL00-0AA0 230V;120/230VAC
6ES7 331-7HF01-0AB0
6ES7 331-1KF02-0AB0
6ES7 331-7KB02-0AB0 模拟量输入模块SM331
6ES7 331-7PF01-0AB0
6ES7 331-7PF11-0AB0
6ES7 331-7NF00-0AB0
6ES7 331-7NF10-0AB0
6ES7 332-5HB01-0AB0
备注中标有多种前连接器的,其连接器分为带螺丝型前连接器,带弹簧型前连接器,带快速连接型前连接器,订货号前三部分与其相应的模块相同,最后一部分分别为:
20针:螺丝型-9AJ0,弹簧型-9BJ0,快速连接型-9CJ0;40针:螺丝型-9AM0,弹簧型-9BM0,快速连接型-9CM0
型号
订货号
6ES7 331-7KF02-0AB0
1000m 1000m 1000m
600m 600m 600m
40x125x120 40x125x120 40x125x120
多种前连接器
数字量输入-安全集成 6ES7 326-1RF00-0AB0 24VDC
SM326 F
6ES7 326-1BK02-0AB0 24VDC
90mA 100mA
40针
6ES7 321-7RD00-0AB0
EX 数字量输入/输出 模块
6ES7 322-SSD00-0AB0
6ES7 322-5RD00-0AB0
24VDC 24VDC 24VDC
80mA 70mA 70mA
20针
4
20针
4
20针
4
200m
注:
电流消耗指从背板总线最大消耗,前连接器为电缆、端子板的,电缆订货号为6ES7 392-4BXX0-0AA0,端子板为6es7392-1XN00-0AA0
8
40针
24
200m 200m
100m 100m
80x125x120 80x125x120
Ex(i)保护模块
数字量输出-安全集成 6ES7 326-2BF10-0AB0 24VDC
SM326 F
6ES7 326-2BF41-0AB0 24VDC
相关文档