SC50-11EWA中文资料
Altech Corp. 50大型接线 terminals 说明书
INTRODUCTIONLUG TYPE TERMINALSOVERVIEWPhillips Screw TerminalLarge CenterMarking AreaSlotted Hex Nut TerminalHex NutTerminalHinge Type Captive Nut TerminalHex Nut Power TerminalD i s c on n ec t &T e s tT e r m i n al s 1 Remove screw/ nut by using wrench/ hex nut driver 2 Place cable with ring/ fork cable lug on stud 3 Tighten screw/ nut to specified torque by usingwrench/hex nut driverCurrent BarHousing Terminal Block Housing • Polyamide PA66 Housing • Self-extinguishing• High mechanical strengthPolyamide 66 Specifications LUG/ STUD TYPE CONNECTION TECHNOLOGYMATERIAL SPECIFICATIONSINSTALLATION GUIDELINESRING LUG TERMINAL CONNECTION TYPES AND FEATURESStud/ Bolt NutUpper Temperature Limit: 105°C Lower Temperature Limit: -50°C Flammability UL94: V2/ V0Volume Resistivity: 1012Ω cm Surface Resistivity: 1010Ω12Secure Connection3Current Carrying MetalCorrosion free material • Bolt: zinc chromate passivated steel• Nut/ Screw: zinc chromate passivated steel• Current Bar: nickel plated copper alloy/ tin plated copperSTUD / RING LUG TERMINALSOVERVIEWFEATURES•Phillips Screw (CBS Series)•Slotted Hex Nut (CSB Series)•22-4 AWG•Up to 85ARing Lug Barrier Terminal BlocksFEATURES•Hex Nut (CSTSN Series)•Slotted Hex Nut (CSTSB Series)•22-2 AWG•Up to 125ARing Lug Stud Terminal BlocksFEATURES•Captive Nut Built-In Hinge•Feed-Through Terminals•Disconnect Terminals•22-2 AWG•Up to 115ARing Lug Hinge Terminal BlocksFEATURES•Nut/Bolt Connection•Threaded Current Bar•10 AWG - 350 kcmil•up to 310ARing Lug Power Terminal BlocksFEATURES•Captive Bolt System•8-4/0 AWG•Up to 230A•Protective Cover•StackableHigh Current Power Terminal Blocks AccessoriesCBS Seriespage 52CSB Seriespage 53CSTSB Seriespage 55 CSTSN Seriespage 54Disconnectpage 57Feed-Throughpage 56CBB Seriespage 58-59PTB Seriespage 60page 61SlottedHex NutHexNutSlottedHex NutCaptiveNut Nut/Bolt Connection Threaded Current Bar- PHILLIPS SCREWWidth ApprovalsHeight w DIN Rail 9 mm CBS3UDimensions & WeightTechnical Data/RatingsInstallation InstructionsTerminal BlocksCBS4U13 mm Length49 mm 49 mm Weight per pieceWire Size (solid / stranded)16-6 AWG 1.5-10 mm 2Voltage Rating 600 V 1000V AC/DCScrewdriver Phillips #2Current Rating 65 A 57 A Insulation MaterialPolyamide 66Torque10 lb-in1.2 NmWire Stripping Length –End Plate AccessoriesStd. Pk.Std. Pk.Cat. No.Cat. No.Std. Pk.Std. Pk.Cat. No.Cat. No.E22051460947-7-138 mm 45.5 mm CBS5U13 mm 49 mm 13.8 g16-4 AWG 1.5-16 mm 2600 V 1000V AC/DCPhillips #2Screw / Stud SizeM4M585 A 76 A Polyamide 6625 lb-in2.0 Nm–Std. Pk.Cat. No.Std. Pk.Cat. No.E22051460947-7-1STUD / RING LUG TERMINALSCBS SERIES50 A Ring Lug Terminal Phillips Screw Head65 A Ring Lug Terminal Phillips Screw Head85 A Ring Lug Terminal Phillips Screw HeadDIN Rail251112020CA701-15/S 20251116010251112020CA701-15/S 20251116010Protective Cover– –CSTSPC2 10CSTSPC2-1 10CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 102 Terminal 3 Terminal 4 Terminal 100 mm 200 mm 300 mm CSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10MT91 Pk. (100 tags)Marking TagMT91 Pk. (100 tags)End Stop EPCBS3U 50CA80250EPCBS3U 50CA80250Insulated Jumper Fork Type CA514/15-2 100CA514/15-3 50CA514/15-4 50CA514/2-2 100CA514/2-3 50CA514/2-4 50Insulated Jumper Ring Lug CA514/17-2 100CA514/17-3 50CA514/17-4 50CA514/4-2 100CA514/4-3 50CA514/4-4 502 pole 3 pole 4 pole 2 pole 3 pole 4 pole 251112020CA701-15/S 20251116010CSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10MT9 1 Pk. (100 tags)EPCBS3U 50CA80250CA514/2-2 100CA514/2-3 50CA514/2-4 50CA514/4-2 100CA514/4-3 50CA514/4-4 50Internal JumperCA728/2 100CA728/3 100CA728/4 100CA728/10 10CA772/2 100CA772/3 100CA772/4 100CA772/10 102 pole3 pole4 pole 10 poleCA772/2 100CA772/3 100CA772/4 100CA772/10 10HIGHLIGHTS•Suitable for standard fork type / ring lug connectors •Version with standard Phillips Screw (CBS Series)•Version with slotted nut (CSB Series)•Compact design•2, 3, 4 pole fork type and ring lug jumpersAPPLICATIONS•Applications with vibration •Machinery •Transportation •Vehicles•Provides solution when ring / fork lug is needed •Compact / Space saving PanelsCBS3U 50CBS3U/R 50CBS3U/BU 50CBS3U/BL 50CBS3U/O 50CBS3U/G 50CBS3U/Y 50CBS3U/W 50CBS4U 50CBS4U/R 50CBS4U/BU 50CBS4U/BL 50CBS4U/O 50CBS4U/G 50CBS4U/Y 50CBS4U/W 50CBS5U 50CBS5U/R 50CBS5U/BU 50CBS5U/BL 50CBS5U/O 50CBS5U/G 50CBS5U/Y 50CBS5U /W 50BARRIER RING LUG TERMINAL BLOCKS - SLOTTED NUTSTUD / RING LUG TERMINALSApprovals9 mm 38 mm 45.5 mm 38 mm 45.5 mm CSB3/N3UDimensions & WeightInstallation InstructionsCSB3/N3UL9 mm 49 mm 49 mm 10.2 g11.7 gWire Size (solid / stranded)22-8 AWG 0.5-6 mm 222-8 AWG 0.5-6 mm 2Voltage Rating 600 V 1000V AC/DC600 V 1000V AC/DCScrewdriverHex Nut Driver 7 mm Flat Head 1.0 x 5.5 mm Current Rating 50 A 41 A 50 A 41 A Insulation MaterialPolyamide 66Polyamide 66Torque4.5 lb-in0.5 Nm4.5 lb-in0.5 NmWire Stripping Length ––End Plate AccessoriesStd. Pk.Std. Pk.Cat. No.Cat. No.Std. Pk.Std. Pk.Cat. No.Cat. No.60947-7-160947-7-138 mm 45.5 mm CSB4/N4U13 mm 49 mm 19.0 g16-6 AWG 1.5-10 mm 2600 V 1000V AC/DCFlat Head 1.0 x 5.5 mm Screw / Stud Size M3M3M465 A 57 A Polyamide 6610 lb-in1.2 Nm–Std. Pk.Cat. No.Std. Pk.Cat. No.60947-7-150 A Ring Lug Terminal Slotted Hex Nut50 A Ring Lug Terminal Long Slotted Hex Nut65 A Ring Lug Terminal Slotted Hex NutDIN Rail251112020CA701-15/S 20251116010251112020CA701-15/S 20251116010MT9 1 Pk. (100 tags)Marking TagMT9 1 Pk. (100 tags)End StopEPCBS3U 50CA80250EPCBS3U 50CA80250251112020CA701-15/S 20251116010MT9 1 Pk. (100 tags)EPCBS3U 50CA80250CSB5/N5U 16-4 AWG 1.5-16 mm 2600 V 1000V AC/DCFlat Head 1.0 x 5.5 mm M585 A 76 A Polyamide 6625 lb-in2.0 Nm–Std. Pk.Cat. No.Std. Pk.Cat. No.60947-7-185 A Ring Lug Terminal 251112020CA701-15/S 20251116010MT9 1 Pk. (100 tags)EPCBS3U 50CA80250Protective Cover– –CSTSPC2 10CSTSPC2-1 10CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 102 Terminal 3 Terminal 4 Terminal 100 mm 200 mm 300 mmCSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10Insulated Jumper Fork Type CA514/15-2 100CA514/15-3 50CA514/15-4 50CA514/2-2 100CA514/2-3 50CA514/2-4 50Insulated Jumper Ring Lug CA514/17-2 100CA514/17-3 50CA514/17-4 50CA514/4-2 100CA514/4-3 50CA514/4-4 502 pole 3 pole 4 pole 2 pole 3 pole 4 pole CSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10CA514/2-2 100CA514/2-3 50CA514/2-4 50CA514/4-2 100CA514/4-3 50CA514/4-4 50Internal JumperCA728/2 100CA728/3 100CA728/4 100CA728/10 10– –CSTSPC2 10CSTSPC2-1 10CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10CA514/15-2 100CA514/15-3 50CA514/15-4 50CA514/17-2 100CA514/17-3 50CA514/17-4 50CA728/2 100CA728/3 100CA728/4 100CA728/10 10CA772/2 100CA772/3 100CA772/4 100CA772/10 102 pole 3 pole 4 pole 10 pole CA772/2 100CA772/3 100CA772/4 100CA772/10 10 Grey (standard) Red R Blue BU Black BL Orange O Green G Yellow Y White WCSB3/N3U 50CSB3/N3U/R 50CSB3/N3U/BU 50CSB3/N3U/BL 50CSB3/N3U/O 50CSB3/N3U/G 50CSB3/N3U/Y 50CSB3/N3U/W 50CSB3/N3UL 50CSB3/N3UL/R 50CSB3/N3UL/BU 50CSB3/N3UL/BL 50CSB3/N3UL/O 50CSB3/N3UL/G 50CSB3/N3UL/Y 50CSB3/N3UL/W 50CSB4/N4U 50CSB4/N4U/R 50CSB4/N4U/BU 50CSB4/N4U/BL 50CSB4/N4U/O 50CSB4/N4U/G 50CSB4/N4U/Y 50CSB4/N4U/W 50CSB5/N5U 50CSB5/N5U/R 50CSB5/N5U/BU 50CSB5/N5U/BL 50CSB5/N5U/O 50CSB5/N5U/G 50CSB5/N5U/Y 50CSB5/N5U /W 50E220514E220514E220514E220514STUD / RING LUG TERMINALSCSTSN SERIESWidthApprovalsHeight w DIN Rail17 mm40.7 mm48.0 mm40.7 mm48.0 mmCSTSN4UDimensions & WeightTechnical Data/RatingsInstallation InstructionsTerminal BlocksCSTSN5U17 mmLength50 mm50 mmWeight per piece21.5 g23.4 gWire Size (solid / stranded)22-4 AWG 1.5-16 mm2Voltage Rating600 V1000V AC/DCCurrent Rating80 A76 AInsulation Material Polyamide 66Torque25 lb-in 2.0 NmDIN Rail251112020CA701-15/S20251116010Accessories Std. Pk.251112020CA701-15/S20251116010Std. Pk.Cat. No.Cat. No.Std. Pk.Std. Pk.Cat. No.Cat. No.60947-7-1MT2B4 1 Pk. (100 tags)Marking Tag MT2B4 1 Pk. (100 tags)End Plate EPCSTSU 50EPCSTSU 5065 A Bolt TerminalM4 Hex Nut80 A Bolt TerminalM5 Hex Nut17 mm40.7 mm48.0 mmCSTSN6U50 mm30.4 g22-2 AWG 1.5-35 mm2600 V1000V AC/DC125 A125 APolyamide 6625 lb-in 3.0 NmStd. Pk.Cat. No.Std. Pk.Cat. No.60947-7-1125 A Bolt TerminalM6 Hex Nut251112020CA701-15/S20251116010MT2B4 1 Pk. (100 tags)EPCSTSU 50Screwdriver Hex Nut Driver 8 mmWire Stripping Length–Hex Nut Driver 9 mmScrew / Stud Size M5M6–End Stop CA80250CA80250CA80250Protective Cover CSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 102 Terminal3 Terminal4 Terminal100 mm200 mm300 mmCSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10InsulatedJumperFork TypeCA514/1-2 100CA514/1-3 50CA514/1-4 50CA514/1-2 100CA514/1-3 50CA514/1-4 50JumperRing LugCA514/3-2 100CA514/3-3 50CA514/3-4 50CA514/3-2 100CA514/3-3 50CA514/3-4 502 pole3 pole4 pole2 pole3 pole4 poleCSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10CA514/7-2 100CA514/7-3 50CA514/7-4 50CA514/8-2 100CA514/8-3 50CA514/8-4 50HIGHLIGHTS•Suitable for standard forktype / ring lug connectors•Version with standard HexNut (CSTSN Series)•Version with slotted barrel(CSTSB Series)•Compact design•2, 3, 4 pole fork type andring lug jumpersAPPLICATIONS•Applications with vibration•Machinery•Transportation•Vehicles•Provides solution whenring / fork lug is needed•Compact / Space savingPanelsCSTSN4U100CSTSN4U/R100CSTSN4U/BU100CSTSN4U/BL100CSTSN4U/O100CSTSN4U/G100CSTSN4U/Y100CSTSN4U/W100CSTSN5U100CSTSN5U/R100CSTSN5U/BU100CSTSN5U/BL100CSTSN5U/O100CSTSN5U/G100CSTSN5U/Y100CSTSN5U/W100CSTSN6U100CSTSN6U/R100CSTSN6U/BU100CSTSN6U/BL100CSTSN6U/O100CSTSN6U/G100CSTSN6U/Y100CSTSN6U /W100E220514E220514STUD TYPE RING LUG TERMINAL BLOCKSSTUD / RING LUG TERMINALSApprovals40.7 mm48.0 mmDimensions & WeightCSTSB4U17 mm50 mm24 gWire Size (solid / stranded)22-6 AWG 1.5-10 mm2Voltage Rating600 V1000V AC/DCCurrent Rating65 A57 AInsulation Material Polyamide 66Torque14 lb-in 1.2 NmEnd PlateAccessories Std. Pk.Cat. No.60947-7-140.7 mm48.0 mmCSTSB5U17 mm50 mm25.5 g22-4 AWG 1.5-16 mm2600 V1000V AC/DC80 A76 APolyamide 6625 lb-in 2.0 NmStd. Pk.Cat. No.60947-7-165 A Bolt TerminalSlotted Barrel65 A Bolt TerminalSlotted BarrelDIN Rail251112020CA701-15/S20251116010Marking Tag MT2B4 1 Pk. (100 tags)EPCSTSU 50251112020CA701-15/S20251116010MT2B4 1 Pk. (100 tags)EPCSTSU 50 Installation InstructionsScrewdriver Flat Head 1.0 x 5.5 mm Flat Head 1.0 x 5.5 mm Wire Stripping Length––Std. Pk.Std. Pk.Cat. No.Cat. No.Screw / Stud Size M4M5End Stop CA80250CA80250Protective Cover CSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 102 Terminal3 Terminal4 Terminal100 mm200 mm300 mmInsulatedJumperFork TypeCA514/1-2 100CA514/1-3 50CA514/1-4 50InsulatedJumperRing LugCA514/3-2 100CA514/3-3 50CA514/3-4 502 pole3 pole4 pole2 pole3 pole4 poleCSTSPC2 10CSTSPC2-1 10– –CSTSPC1-2 10CSTSPC1-3 10CSTSPC1-4 10CA514/1-2 100CA514/1-3 50CA514/1-4 50CA514/3-2 100CA514/3-3 50CA514/3-4 50 Grey (standard)Red RBlue BUBlack BLOrange OGreen GYellow YWhite WCSTSB4U100CSTSB4U/R100CSTSB4U/BU100CSTSB4U/BL100CSTSB4U/O100CSTSB4U/G100CSTSB4U/Y100CSTSB4U/W100CSTSB5U100CSTSB5U/R100CSTSB5U/BU100CSTSB5U/BL100CSTSB5U/O100CSTSB5U/G100CSTSB5U/Y100CSTSB5U/W100E220514E220514STUD / RING LUG TERMINALSSTH SERIESHIGHLIGHTStype / ring lugs •Captive nut system •Only standard flat head screw driver needed to tighten connection•IP20 touch proof terminals with hinged plastic cover •2, 3, 4 pole fork type and ring lug jumpersAPPLICATIONS•Applications with vibration •Machinery •Transportation •Vehicles•Provides solution whenring / fork lug is needed9 mm 47.3 mm 54.8 mm STH3Technical Data/RatingsSTH3STH3/R STH3/BU STH3/BL STH3/O STH3/G STH3/Y STH3/W Terminal BlocksSTH4STH611 mm 52.2 mm 59.0 mm STH4STH4/R STH4/BU STH4/BL STH4/O STH4/G STH4/Y STH4/W 18 mm 63.1 mm 70.6 mm STH650STH6/R 50STH6/BU 50STH6/BL 50STH6/O 50STH6/G 50STH6/Y 50STH6/W 5047 mm 46 mm 64 mm 15.0 g62.5 g57.8 g22-2 AWG 1.5-35 mm 2600 V 1000V AC/DC115 A 125 A Polyamide 6625 lb-in3.0 NmStd. Pk.Cat. No.Cat. No.Cat. No.60947-7-160947-7-1EPSTH3 50251112020CA701-15/S 20251116010CA702100CA80250CA20250CA514/17-2100CA514/17-350CA514/17-450MT8 1 Pk. (100 tags)Std. Pk.Cat. No.End Plate DIN RailEnd StopInsulated Jumpers Ring Lug Marking Tag EPSTH4 50251112020CA701-15/S 20251116010CA702100CA80250CA20250CA514/14-2100CA514/14-350CA514/14-4502 pole3 pole4 pole MT10 1 Pk. (100 tags)AccessoriesStd. Pk.EPSTH6 50251112020CA701-15/S 20251116010CA702100CA80250CA20250– –– –– –MT16 1 Pk. (100 tags)Std. Pk.Cat. No.Cat. No.CA773/2100CA773/350CA773/450CA773/1010Internal Jumpers– –– –– –– –2 pole 3 pole 4 pole 10 poleCA774/2100CA774/350CA774/450––Installation InstructionsFlat Head 1.0 x 5.5 mm M6–CA512/15-2100CA512/15-350CA512/15-450Jumpers Fork Type CA512/13-2100CA512/13-350CA512/13-450– –– –– –CA514/15-2100CA514/15-350CA514/15-450Insulated Jumpers Fork Type CA514/13-2100CA514/13-350CA514/13-450– –– –– –CA512/17-2100CA512/17-350CA512/17-450Jumpers Ring Lug CA512/14-2100CA512/14-350CA512/14-450– –– –– –2 pole 3 pole 4 pole 2 pole 3 pole 4 pole 2 pole 3 pole 4 pole E220514E220514STUD / RING LUG TERMINALSSTH SERIESWidth ApprovalsHeight w DIN Rail 35 x 7.5 mm35 x 15 mm Dimensions & WeightGreyTerminal BlocksSTH4DTDisconnect /Test Application for Metering CTLCSTH4DT Lockout CapSTH4DT Disconnect TerminalQJ11/2Shorting PlugCA514/14-3STH4DTSHSTH4DT 5022 mm 52.2 mm 59.0 mm Length86 mm Weight per pieceWire Size (solid / stranded)22-8 AWG 1.5-6 mm 2Voltage Rating 600 V 1000V AC/DCCurrent Rating 35 A 41 A Insulation MaterialPolyamide 66Torque14 lb-in1.2 NmStd. Pk.Cat. No.60947-7-1End Plate DIN RailEnd StopInsulated Jumpers Ring Lug Marking TagEPSTH4DT 50251112020CA701-15/S 20251116010CA702100CA80250CA20250CA514/14-2100CA514/14-350CA514/14-4502 pole 3 pole 4 pole MT10 1 Pk. (100 tags)AccessoriesStd. Pk.EPSTH4DT 50251112020CA701-15/S 20251116010CA702100CA80250CA20250CA514/14-2100CA514/14-350CA514/14-450MT10 1 Pk. (100 tags)Std. Pk.Cat. No.Cat. No.Installation InstructionsScrewdriverFlat Head 0.8 x 4 mm Wire Stripping Length –Screw / Stud Size M4Jumpers Fork Type CA512/13-2100CA512/13-350CA512/13-450CA512/13-2100CA512/13-350CA512/13-450Insulated Jumpers Fork Type CA514/13-2100CA514/13-350CA514/13-450CA514/13-2100CA514/13-350CA514/13-450Jumpers Ring Lug CA512/14-2100CA512/14-350CA512/14-450CA512/14-2100CA512/14-350CA512/14-450STH4DTFT11 mm 52.2 mm 59.0 mm 86 mm EPSTH4DT 50251112020CA701-15/S 20251116010CA702100CA80250CA20250CA514/14-2100CA514/14-350CA514/14-450Insulated Alternate Jumpers CA514/14-3A 10CA514/14-4A 103 pole 4 poleCA514/14-3A 10CA514/14-4A 10CA514/14-3A 10CA514/14-4A10MT10 1 Pk. (100 tags)Shorting Plug QJ11/225QJ11/225– –Lock Out Cap LCSTH4DT25LCSTH4DT25– –Std. Pk.Cat. No.CA512/13-2100CA512/13-350CA512/13-450CA514/13-2100CA514/13-350CA514/13-450CA512/14-2100CA512/14-350CA512/14-4502 pole 3 pole 4 pole 2 pole 3 pole 4 pole 2 pole 3 pole 4 pole FEATURES•Bolt Disconnect Terminals •Disconnect (STH4DT )•2 Shorted DisconnectTerminals (STH4DTSH )•Feed-Through with same profile (STH4DTFT )•Suitable for standard fork type / ring lugs •Captive nut system•IP20 touch proof terminals with hinged plastic cover •2, 3, 4 pole fork type and ring lug jumpersAPPLICATIONS •Disconnect / TestApplications•Measuring / Control Circuit •Utility Instruments and Transformer Applications •Meter Replacement •External Current MeasurementDouble Disconnect TerminalBlockFeed-Through Terminal BlockDisconnect ProfileE220514Width ApprovalsHeight w DIN Rail 32 mm 47.5 mm Dimensions & WeightTechnical Data/RatingsInstallation InstructionsCBB70CBB70LSLength75 mm Weight per pieceWire Size (solid / stranded)8-2/0 AWG 6-70.0 mm 2Voltage Rating 600 V 1000V AC/DCScrewdriverWrench M8Flat Head 1 x 1.5 mmCurrent Rating 175 A 192 A Insulation MaterialPolyamide 66Torque54.5 lb-in6.0 NmWire Stripping Length –Partition Plate AccessoriesStd. Pk.Std. Pk.Cat. No.Cat. No.60947-7-1CBB95CBB95LS8-4/0 AWG 16-95.0 mm 2600 V 1000V AC/DCWrench M10Flat Head 1 x 1.5 mmScrew / Stud Size M8M10230 A 232 A Polyamide 6690 lb-in10.0 Nm–Std. Pk.Cat. No.60947-7-1STUD / RING LUG TERMINALSCBB SERIES150 A Feed Through Power TerminalMT12 1 Pk. (100 tags)Marking TagMT16 1 Pk. (100 tags)PPCBB 50PPCBB 50Protective Cover for installing on PPCBB & PPCBB1CBBPC1/70 10CBBPC1/80 10CTSPC2-1 10CBBPC1/130 10CBBPC1/160 10CBBPC1/200 10CBBPC1/250 10CBBPC1/70 10CBBPC1/80 10CTSPC2-1 10CBBPC1/130 10CBBPC1/160 10CBBPC1/200 10CBBPC1/250 10Permanent Jumper Bars CA790/2 10CA790/3 10CA791/2 10CA791/3 1070 mm 80 mm 100 mm 130 mm 160 mm 200 mm 250 mm2 pole3 pole MT16 1 Pk. (100 tags)PPCBB1 50– –– –CBBPC2/100 10– –CBBPC2/160 10CBBPC2/200 10CBBPC2/250 10CA791/2 10CA791/3 10 Terminal BlocksCBB7010CBB70LS 10CBB9510CBB95LS 10Std. Pk.Std. Pk.Cat. No.Cat. No. HIGHLIGHTSFEATURES•High Current up to 310A •Feed-Through Terminals •Nut / Bolt version•Version with threadedcurrent bar (LS) for fast wiring without 2wrenches•Wire crimped into ring /fork lug on to the flat cur-rent bar•Special Mounting foot design for tight fit on rail •Protective Cover in vari-ous length•2, 3 pole jumper barsAPPLICATIONS •High Current Power Applications •Large size wires•Power Distribution Feed-ing Applications•Provides solution when ring / fork lug is neededDIN Rail 251112020CA701-15/S 20251112020CA701-15/S 20End Stop CA10250CA20250CA10250CA20250251112020CA701-15/S 20CA10250CA20250E220514E220514RING LUG TYPE POWER TERMINAL BLOCKSSTUD / RING LUG TERMINALSCBB SERIESWidthApprovalsHeight w DIN Rail 35 x 7.5 mm35 x 15 mm CBB120CBB120LSDimensions & WeightInstallation InstructionsCBB150CBB150LSLengthWeight per pieceWire Size (solid / stranded)8-250 KCMIL16-120 mm 28-300 KCMIL16-150 mm 2Voltage Rating 600 V 1000V AC/DC 600 V 1000V AC/DC Current Rating 255 A 269 A 285 A 309 A Insulation MaterialPolyamide 66Polyamide 66Torque90 lb-in10.0 Nm127 lb-in14.0 NmWire Stripping Length ––Partition Plate AccessoriesStd. Pk.Std. Pk.Cat. No.Cat. No.60947-7-160947-7-1CBB185CBB185LS8-350 KCMIL16-185 mm 2600 V 1000V AC/DCScrew / Stud Size M10M12M12310 A 353 A Polyamide 66127 lb-in14.0 Nm–Std. Pk.Cat. No.60947-7-1DIN Rail 251112020CA701-15/S 20251112020CA701-15/S 20MT16 1 Pk. (100 tags)Marking TagMT16 1 Pk. (100 tags)End Stop PPCBB1 50CA10250CA20250PPCBB1 50CA10250CA20250Protective Cover for installing on PPCBB & PPCBB1CBBPC2/100 10CBBPC2/160 10CBBPC2/200 10CBBPC2/250 10CBBPC2/100 10CBBPC2/160 10CBBPC2/200 10CBBPC2/250 10Permanent Jumper Bars CA793/2 10CA793/3 10CA794/2 10CA794/3 10100 mm 160 mm 200 mm 250 mm2 pole3 pole 251112020CA701-15/S 20MT16 1 Pk. (100 tags)PPCBB1 50CA10250CA20250CBBPC2/100 10CBBPC2/160 10CBBPC2/200 10CBBPC2/250 10CA794/2 10CA794/3 10 GreyNut & Bolt configuration Threaded Current BarCBB12010CBB120LS 10Terminal BlocksCBB15010CBB150LS 10CBB18510CBB185LS 10Std. Pk.Std. Pk.Std. Pk.Cat. No.Cat. No.Cat. No.ScrewdriverWrench M10Flat Head 1 x 1.5 mmWrench M12Flat Head 1 x 1.5 mmWrench M12Flat Head 1 x 1.5 mmE220514E220514E220514HIGH CURRENT POWER TERMINAL BLOCKS• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-94906025 mm 61.0 / 66.5 mm 68.3 / 73.6 mm PTB35/50PTB35/50SHGreyPTB35/5010PTB35/50SH 10Terminal BlocksPTB70/95PTB70/95SH113 / 169 mm 112.0 / 130.5 g8-2 AWG 1.5-50 mm 2600 V 1000V AC/DC 115 A 150 A Polyamide 6627 lb-in3.0 NmDIN Rail End Stop Marking Tag 251112020CA701-15/S 20CA10250CA20250MT9 1 Pk. (100 tags)AccessoriesStd. Pk.Cat. No.Std. Pk.Cat. No.60947-7-1STUD / RING LUG TERMINALSPTB SERIESMarking Tag HolderMHPTB35Hex Nut Driver 10 mm–M632 mm 76.6 / 78.0 mm 84.5 / 86.0 mm PTB70/9510PTB70/95SH 10130 / 192 mm 174.4 / 198.2 g8-4/0 AWG 1.5-95 mm 2600 V 1000V AC/DC 230 A 232 A Polyamide 6687 lb-in10.0 Nm251112020CA701-15/S 20CA10250CA20250Jumper SystemCA703/910CA704/910CA705/910CA703/1110CA704/1110CA705/1110MT9 1 Pk. (100 tags)Protective Cover PSPTB3520PSPTB7010Std. Pk.Cat. No.Std. Pk.Cat. No.60947-7-1MHPTB35Hex Nut Driver 13 mm–M8HIGHLIGHTS(PSPTBXX )•Modular / stackable design •2, 3, 4 pole jumper systemAPPLICATIONS •High Current Power Applications •Large size wires•Power Distribution Feeding Applications•Provides solution when ring / fork lug is neededPTB35/50PTB35/50SHPTB70/95PTB70/95SH2 pole3 pole4 poleMarking Tag HolderMHPTB35Protective Cover PSPTB35E220514E220514JUMPERS / SHORTING LINKS• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-949061STUD / RING LUG TERMINALSACCESSORIESCBS3UCSB3/N3U CSB3/N3ULSTH3CBS4UCBS5UCSB4/N4UL CSB5/N5U CSTSN4U CSTSN5U CSTSN6U CSTSB4U CSTSB5U CSTSN6U STH4STH4DT STH4DTFT STH6Terminal Block 2 Pole 3 Pole 4 Pole 10 Pole 2 Pole 3 Pole 4 Pole 10 Pole 2 Pole 3 Pole 4 Pole 2 Pole 3 Pole 4 Pole 2 Pole 3 Pole 4 Pole 2 Pole 3 Pole 4 PoleCA512/15-2CA512/15-3CA512/15-4CA512/2-2CA512/2-3CA512/2-4CA512/1-2CA512/1-3CA512/1-4CA512/7-2CA512/7-3CA512/7-4CA512/13-2CA512/13-3CA512/13-4 N/A10050501005050100505010050501005050100505010050501005050100505010050501005050100505010050501005050100505010050501005050100505010050501005050505050101005050101005050CA514/15-2CA514/15-3CA514/15-4CA514/2-2CA514/2-3CA514/2-4CA514/1-2CA514/1-3CA514/1-4CA514/7-2CA514/7-3CA514/7-4CA514/13-2CA514/13-3CA514/13-4 N/ACA512/17-2CA512/17-3CA512/17-4CA512/4-2CA512/4-3CA512/4-4CA512/3-2CA512/3-3CA512/3-4CA512/8-2CA512/8-3CA512/8-4CA512/14-2CA512/14-3CA512/14-4 N/ACA514/17-2CA514/17-3CA514/17-4CA514/4-2CA514/4-3CA514/4-4CA514/3-2CA514/3-3CA514/3-4CA514/8-2CA514/8-3CA514/8-4CA514/14-2CA514/14-3CA514/14-4 N/A1010N/A N/A N/AN/ACA514/14-3A CA514/14-4A CA728/2CA728/3CA728/4CA728/10CA772/2CA772/3CA772/4CA772/10 N/AN/A N/A CA774/2CA774/3CA774/4Length Cat. No. Std. Pk.100mm CSTSPC1-2 10200mm CSTSPC1-3 10300mmCSTSPC1-410For CBS, CSB, CSTS SeriesAlternate Jumper for STH4DT SeriesTerminal BlockCBS Series CSB Series CSTSN Series CSTSB Series STH3STH4STH6STH4DTDimensions 26.2 x 49 x 1.5 mm 31 x 50 x 1.5 mm 34 x 47 x 1.5 mm 39.5 x 46 x 1.5 mm 51 x 63.5 x 1.5 mm 37.5 x 86 x 1.5 mmCat. No EPCBS3U EPCSTSU EPSTH3EPSTH4EPSTH6EPSTH4DTDimensions 32 x 45 x 8 mm Cat. No CA802Dimensions 34 x 45 x 9 mm Cat. No CA702Dimensions 44.5 x 50 x 9.5 mm Std. Pk.50Std. Pk.50Std. Pk.50Cat. No CA202Std. Pk.505050505050Fork Type Jumper Insulated Fork TypeJumperRing Lug JumperInsulated Ring LugJumperInternal JumperEND STOPSENDPLATES / PROTECTIVE COVERSCA802CA707CA202。
IRFS11N50A中文资料
100
1000
OPERATION IN THIS AREA LIMITED BY RDS(on)
ISD , Reverse Drain Current (A)
100
10
ID , Drain Current (A)
TJ = 150 ° C
10us 10 100us 1ms 1 10ms
1
TJ = 25 ° C
I D , Drain-to-Source Current (A)
2.5
10
2.0
TJ = 150 ° C TJ = 25 ° C
1
1.5
1.0
0.5
0.1 4.0
V DS = 50V 20µs PULSE WIDTH 5.0 6.0 7.0 8.0 9.0
0.0 -60 -40 -20
VGS = 10V
Min. 500 ––– ––– 2.0 ––– ––– ––– –––
Typ. ––– 0.060 ––– ––– ––– ––– ––– –––
Max. Units Conditions ––– V VGS = 0V, ID = 250µA ––– V/°C Reference to 25°C, ID = 1mA 0.52 Ω VGS = 10V, ID = 6.6A 4.0 V VDS = VGS, ID = 250µA 25 VDS = 500V, VGS = 0V µA 250 VDS = 400V, VGS = 0V, TJ = 125°C 100 VGS = 30V nA -100 VGS = -30V
3
元器件交易网
IRFS11N5OA
2400
2000
VGS , Gate-to-Source Voltage (V)
CWR11JH105JMA中文资料
©KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-630020•Establ i shed rel i ab i l i ty m i l i tary vers i on of Industr i al Grade T491 ser i es •Taped and reeled per EIA 481-1•Prec i s i on-molded, laser-marked case •Symmetr i cal, compl i ant term i nat i ons•100% Surge Current test ava i lable for all case s i zes •Operat i ng Temperature : -55˚C to + 125˚C•Qual i f i ed to MIL-PRF-55365/8, Style CWR11:–Term i nat i on Options B, C, H, K–We i bull fa i lure rate codes B, C and D–Capac i tance values and voltages as shown i n follow i ng part number table . (Contact KEMET for latest qual i f i cat i on status)DIMENSIONS – M i ll i meters (Inches)T492 SERIES ORDERING INFORMATION —KEMET Part NumberORDERING INFORMATION — MIL-PRF-55365 Part Number#Note on Fa i lure Rates : Exponent i al fa i lure rate levels M, P, R and S are i nact i ve for new des i gn per M i l-C-55365.Parts qual i f i ed to We i bull fa i lure rate levels are subst i tutable for exponent i al fa i lure rate levels .WKXCATHODE (-) ENDVIEWSIDE VIEWANODE (+) ENDVIEWTGSSBBHBOTTOM VIEWE FA LTermination cutout at KEMET s Option,either endRPT492OUTLINE DRAWINGS* Part Number Example: T492B105K035BS (14 digits - no spaces)* See for Pb Free transition.Surge Current Option4250 = +25°C after Weibull4251 = -55° +85°C after Weibull 4252 = -55, & +85°C before WeibullLead MaterialB = GoldC = Hot Solder Dip H or S = Solder Plated K = Solder FusedCapacitance TolerancesM = ±10%; K = ±10%; J = ±5%Failure Rate SymbolWeibull: B (0.1%/1000 hrs.); C (0.01%/1000 hrs.); D (0.001%/1000 hrs.)# Exponential: M (1.0%/1000 hrs.); P (0.1%/1000 hrs.), R (0.01%/1000 hrs.); S (0.001%/1000 hrs.) # Exponential not recommended for new designTantalum SeriesT492 - Precision Molded, Style CWR11Case SizeA, B, C, DCapacitance Picofarad CodeFirst two digits represent significant figures.Third digit specifies number of zeros to follow.T492B 105K 035B S 4250VoltageAs shownSurge Current OptionA = +25°C after WeibullB = -55°C +85°C after Weibull C = -55°, & +85°C before Weibull Z = NoneCapacitance TolerancesM = ±10%; K = ±10%; J = ±5%Failure Rate SymbolWeibull:B (0.1%/1000 hrs.)C (0.01%/1000 hrs.)D (0.001%/1000 hrs.)#Exponential:M (1.0%/1000 hrs.)P (0.1%/1000 hrs.)R (0.01%/1000 hrs.)S (0.001%/1000 hrs.)StyleCapacitors, Chip, Fixed TantalumEstablished Reliability, (encapsulated)VoltageD = 6V J = 20V F = 10V K = 25V H = 15V M = 35VCapacitance Picofarad CodeFirst two digits represent significant figures.Third digit specifies number of zeros to follow.CWR11M H 105K B ATermination Finish CodeB = Gold PlatedC = Hot Solder Dipped H = Solder PlatedK = Solder Fused# Inactive for New Design Case SizeComponentKEMET EIA L*W*H*K*± 0.20± (.008)F*± 0.1± (.004)S*± 0.3± (.012)B ± 0.15(Ref) ± .006X (Ref)P (Ref)R (Ref)T (Ref)A (Min)G (Ref)E (Ref)A 3216-18 3.2 ± 0.2(.126 ± .008) 1.6 ± 0.2(.063 ± .008) 1.6 ± 0.2(.063 ± .008)0.9(.035) 1.2(.047)0.8(.031)0.4(.016)0.10 ± 0.10(.004 ± .004)0.4(.016)0.4(.016)0.13(.005) 1.4(.055) 1.1(.043) 1.3(.051)B 3528-21 3.5 ± 0.2(.138 ± .008) 2.8 ± 0.2(.110 ± .008) 1.9 ± 0.2(.075 ± .008) 1.1(.043) 2.2(.087)0.8(.031)0.4(.016)0.10 ± 0.10(.004 ± .004)0.5(.020) 1.0(.039)0.13(.005) 2.1(.083) 1.8(.071) 2.2(.087)C 6032-28 6.0 ± 0.3.236 ± .012 3.2 ± 0.3(.126 ± .012) 2.5 ± 0.3(.098 ± .012) 1.4(.055) 2.2(.087) 1.3(.051)0.5(.020)0.10 ± 0.10(.004 ± .004)0.9(.035) 1.0(.039)0.13(.005) 3.1(.122) 2.8(.110) 2.4(.094)D7343-317.3 ± 0.3(.287 ± .012)4.3 ± 0.3(.169 ± .012)2.8 ± 0.3(.110 ± .012)1.5(.059)2.4(.094)1.3(.051)0.5(.020)0.10 ± 0.10(.004 ± .004)0.9(.035) 1.0(.039)0.13(.005)3.8(.150) 3.5(.138) 3.5(.138)2. (Ref) Dimensions provided for reference only* Mil-PRF-55365/8 Specified DimensionsSOLID TANTALUM CHIP CAPACITORST492 SERIES – Style CWR11 Per Mil-PRF-55365/821PolarityIndicator (+)Picofarad Code KEMETI. D. SymbolRated Voltage15620K 513J Jan BrandPrint Week Code:1st Digit = Year 2nd & 3rd Digits = Week"513" = The 13th week of 2005ESR @ +25ЊC 100kHz MaxSOLID TANTALUM CHIP CAPACITORST492 SERIES—Style CWR11 Per Mil-PRF-55365/8©KEMET Electron i cs Corporat i on, P .O . Box 5928, Greenv i lle, S .C . 29606, (864) 963-6300CONSTRUCTIONCAPACITOR MARKINGST492 Series — All Case SizesNote on Failure Rates:Exponential failure rate levels M, P, R and S are inactive for new design per MIL-C-55365. Parts qualified to Weibull failure rate levels are substitutable for exponential failure rate levels.Note: ESR limits are per Mil-C-55365/8AND PART NUMBER REFERENCENegative Termination*Mn02 Coat(First Layer)Silver Paint(Third Layer)Tantalum WireCarbon(Second Layer)Tantalum(Ta 2O 5)Molded CaseSilver AdhesiveWasherPositive TerminationWeldPolarity Stripe (+)Polarity Bevel (+)S o l i d T a n t a l u m S u r f a c e M o u n tSn/Pb (5% Pb minimum)ESR:ESR: @ +25°C 100kHz Max8.08.08.05.54.53.53.02.21.110.08.08.05.54.53.52.51.112.010.08.05.55.04.02.51.114.012.010.06.05.04.03.02.41.115.014.07.56.56.53.53.52.51.41.224.021.018.015.010.08.06.54.53.52.51.5(2) To complete KEMET/CWR part number, insert Failure Rate Symbol Weibull: B (0.1%/1000 Hrs.), C (0.01%/1000Hrs or D (0.001%/1000 Hrs.),(3) To complete KEMET part number, insert Termination Finish Designation B = Gold; C = Hot Solder Dipped; S = Solder Plated; K = Solder Fused.PACKAGINGNote: T492 Packaging• No c-spec required for 7” reel packaging • C-7280 required for 13” reel packaging • Standard reel packaging is not mandatory • Bulk packaging also available using C-7610 See page 91 for tape and reel quantities.©KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300Tape & Reel PackagingKEMET’s Molded Tantalum and Aluminum Chip Capacitor families are packaged in 8 mm and 12 mm plastic tape on 7" and 13" reels, in accordance with EIA Standard 481-1: Taping of Surface Mount Components for Automatic Handling. This packaging system is compatible with all tape fed automatic pick and place systems.Right Hand Orientation Only(+)(–)Embossed CarrierEmbossmentTop T ape Thickness.10mm (.004") Max Thickness8mm ±.30(.315±.012")or12mm ±.30(.472±.012")178mm (7.00")or 330mm (13.00")8mm (0.315")or12mm (0.472")180mm (7.0")330mm (13.0")QUANTITIES PACKAGED PER REELCase Code TapeKEMET EIA Width-mm7" Reel*13" Reel*R 2012-1282,50010,000S 3216-1282,50010,000T 3528-1282,50010,000U 6032-15121,0005,000W 7343-15121,0003,000V 7343-20121,0003,000A 3216-1882,0009,000B 3528-2182,0008,000C 6032-28125003,000D 7343-31125002,500Y 7343-40125002,000X 7343-43125002,000E 7260-38125002,000* No c-spec required for 7" reel packaging. C-7280 required for 13" reel beling:Bar code labeling (standard or custom) shall be on the side of the reel opposite the sprocket holes.Refer to EIA-556.TANTALUM AND ALUMINUM CHIP CAPACITORSPackaging Information92Performance Notes1.Cover Tape Break Force: 1.0 Kg Minimum.2.Cover Tape Peel Strength: The total peel strength of the cover tape from the carrier tape shall be:Tape Width Peel Strength8 mm 0.1 Newton to 1.0 Newton (10g to 100g)12 mm 0.1 Newton to 1.3 Newton (10g to 130g)The direction of the pull shall be opposite the direction of the carrier tape travel. The pull angle of the carrier tape shall be 165Њto 180Њfrom the plane of the carrier tape. During peeling, the carrier and/or cover tape shall be pulled at a velocity of 300 ±10 mm/minute.3.Reel Sizes:Molded tantalum capacitors are available on either 180 mm (7") reels (standard) or 330 mm (13")reels (with C-7280). Note that 13” reels are preferred.beling: Bar code labeling (standard or custom) shall be on the side of the reel opposite the sprocket holes.Refer to EIA-556.Embossed Carrier Tape Configuration: Figure 1NOTES1.B1 dimension is a reference dimension for tape feeder clearance only.2.The embossment hole location shall be measured from the sprocket hole controlling the location of the embossment. Dimensions of embossment location and hole location shall be applied independent of each other.3.Tape with components shall pass around radius “R ” without damage (see sketch A). The minimum trailer length (Fig. 2) may require additional length to provide R min. for 12 mm embossed tape for reels with hub diameters approaching N min. (Table 2)4.The cavity defined by A ,B ,and K shall be configured to surround the part with sufficient clearance such that the chip does not pro-Table 1 — EMBOSSED TAPE DIMENSIONS (Metric will govern)Constant Dimensions — Millimeters (Inches)Tape Size D 0EP 0P 2T Max T 1Max 8 mm 1.5 1.75 ±0.10 4.0 ±0.10 2.0 ±0.050.6000.100and +0.10 -0.012 mm(0.059(0.069 ±0.004)(0.157 ±0.004)(0.079 ±0.002)(0.024)(0.004)+0.004, -0.0)Variable Dimensions — Millimeters (Inches)Tape Size Pitch B 1Max.D 1Min.F P 1R Min.T 2Max W A 0B Note 1Note 2Note 3Note 48 mmSingle 4.4 1.03.5 ±0.054.0 ±0.1025.02.58.0 ±0.30(4 mm)(0.173)(0.039)(0.138 ±0.002)(0.157 ±0.004)(0.984)(0.098)(.315 ±0.012)12 mmDouble 8.2 1.5 5.5 ±0.058.0 ±0.1030.0 4.612.0 ±0.30(8 mm)(0.323)(0.059)(0.217 ±0.002)(0.315 ±0.004)(1.181)(0.181)(0.472 ±0.012)Packaging Information©KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300Embossed Carrier Tape Configuration (cont.)Sketch D: Tape Camber (Top View)Allowable camber to be 1 mm/250 mm.250mm (9.843)1mm (0.039) Max.(Metric will govern)Reel Dimensions (Metric Dimensions will govern)N Min W 1W 2Max W 350.08.414.47.9 Min (1.969)+1.5, -0.0(0.567)(0.311)See (0.33110.9 Max Note 3+0.059, -0.0)(0.429)Table 112.418.411.9 Min Packaging Information400mm (15.75) Min.20°95。
西格玛安全截止阀S 50产品信息说明书
Safety Shut-Off ValveS 50Product informationAC Accuracy classAG o Upper response pressure group AG u Lower response pressure group BV Breather valveGPR Gas pressure regulator HDS High-pressure spindle K G Valve flow rate coefficient p Pressure p d Outlet pressure p df SRV closing pressure p do SRV opening pressure p ds Setpoint of the response pressurep ds oUpper SSV response pressure p ds u Lower SSV response pressure p f,max Maximum closing pressure PS Maximum allowable pressure p u Inlet pressureQ n Standard volumetric flow rate RE Diaphragm assembly RSD2 Throttle valveSSV Safety shut-off valve SRV Safety relief valveSG Closing pressure group t Gas Gas inlet temperature VS Valve seatw d Outlet gas velocity w uInlet gas velocityW ds o Upper spring adjustment range (SSV)W ds u Lower spring adjustment range (SSV)Δp Pressure difference from inlet pressure to outlet pressure Δp wo Min. re-engagement difference between upper response pressure and normal operating pressure Δp wu Min. re-engagement difference between lower response pressure and normal operating pressure ρn Gas densityTable of ContentsApplication, Characteristics, Technical Data 4Application 4Characteristics 4Type of models / Options (see page 10) 4Technical data 5Structure and function 6Sectional view 7SSV setpoint spring table - control device 8Dimensions, Connection, and Weight 9Dimensional drawing 9Dimensions and weight 9Connection of the measuring lines and breather lines 9Types of Models / Options 10Design 11Properties of Gases 11Order Data 12Notes 13Contact 14Notes 16Observe the following publications in relation toinstallation, start-up and maintenance: DVGW - work sheets G 491 and G 600Operating and Maintenance Instructions S50ATTENTION List of abbreviations and formula symbolsApplication, Characteristics, Technical DataApplicationSafety shut-off valve (SSV), direct-acting (operating without auxiliary power), for systems acc. to DVGW work sheets G 491 (A) and G 600 (A) (TRGI)Can be used for the gases defined in DVGW work sheet G 260 / G 262 and neutral non-aggressive gases. (other gases on request)Characteristics• Integral pressure-tight version (IS)• High flow rate capacity• Open-air model• with BV breather valve• with electric position indicator SSV 'Closed' via inductive proximity initiator or via reed contact • with SSV electromagnetic remote release when power is applied or in case of power failure• with SSV manual release• oxygen model• hydrogen modelResponse pressure groupsLower response pressure AGu incommand area wdsu AG U Upper response pressure group AGoin command area wdsoAGo10 mbar to 50 mbar2050 mbar to 500 mbar10> 50 mbar10> 500 mbar5 Type of models / Options (see page 10)Technical dataType S 50ModelIntegral pressure-tight (IS)Max. allowable pressure PS 3 barNominal width Rp 1“ (DN 25), Rp 1½“ (DN 40), Rp 2“ (DN 50)(NPT thread on request)Standard volumetric flow rate Q n,max Rp 1“: 100m³/h, Rp 1½“: 300m³/h, Rp 2“: 300m³/h Type of connection Internal thread acc. to EN 10226-1MaterialHousing / actuator housing/ Control device housing Al cast alloy DIN EN 1706-AC-42100 ST6Corrosivity categoryDIN EN ISO 12944-2C1 to C5-I without additional coatingsC5-Man epoxy resin coating is recommended (see page10)Temperature range, Class 2-20°C to +60°C (operating/ambient temperature)Function, strength and tightness DIN EN 14382CE mark acc. to PED/ PIN number C E -0085-BS0420Ex protection The mechanical parts of the device do not have anypotential ignition sources of their own and therefore do not fall within the scope of ATEX 95 (94/9/EC). Electrical components fitted to the devicecomply with the ATEX requirements.Preferred installation positionThe safety shut-off valves (SSV) shall be installed in the pipeline preferably in horizontal position. For all nominal widths, the direction of flow is indicated by an arrow on the housing.Note: Observe the following documents in relation to installation, start-up, and maintenance:• DVGW - work sheets G 491 and G 600• Operating and Maintenance Instructions S50Installation upside down only after consultation with Medenus GmbHStructure and functionThe safety shut-off valve S 50 shuts off the gas flow when the outlet pressure in the regulation section exceeds or falls below a certain response pressure. To this end, the outlet pressure to be monitored is passed on to the SSV control device via a separate measurement line. As a function of the change in pressure, the diaphragm in the control device is raised or lowered. When the outlet pressure in the regulation section falls below the lower switch-off point or exceeds the upper switch-off point, the switch socket connected to the SSV diaphragm will move to the corresponding disengaging position, the balls of the engaging mechanism will release the SSV screw spindle, and the closing spring will press the SSV valve plate against the valve seat. The SSV actuator shuts off the gas flow gas-tight.The SSV can only be opened by hand and engaged in the open position. To do so, the outlet pressure at the measuring point must be lowered below the upper response pressure or raised above the lower response pressure by at least the re-engaging differential amount (Δp).The SSV can, except where otherwise stipulated in specific national legislation, be used in either functional class A (with diaphragm rupture protection) or B (without diaphragm rupture protection).There is also the option of using a remote display for the SSV position “CLOSED” and a manual and remote release when power is applied or in case of power failure.Installation exampleP 1P 2m in . 5x D NInlet OutletRange formeasuring points*(approx. 3x DN P 2)*) Recommended max. velocity at the measurement line port 25 m/sKSN75DF100S50SL10R50Sectional viewActuator housingValve seatActuatorBall detentRe-engagement unitDiaphragmSetting screw for lowerresponse pressureSetting screw for upperresponse pressure*) Standard spring**) If the control device is set up for simultaneous monitoring of upper and lower response pressures, the differencebetween the setpoints for the upper and lower response pressures (pdso and pdsu) should be at least 10% greater than thetotal of values given for Δpwo and Δpwu.SSV setpoint spring table - control deviceB ALYDimensions, Connection, and WeightDimensional drawingConnection of the measuring lines and breather linesNominal width MeasurementlineBreather lineDN 025 Rp 1“Connection* for: tube 12 x 1.5 (thread G 1/4)DN 040 Rp 1½“DN 050 Rp 2“Reactivation of SSVDimensions and weightInductivetransmitterSignal transmitterTypes of Models / OptionsSSV manual and remote releaseReed contacts and inductive transmittersare used to monitor the position (closed oropen position) of the safety shut-off valvevia remote display.Reed contact / inductive transmitterThe direct-acting safety solenoid valve is used aselectromagnetic remote release for closing the safetyshut-off valve when power is applied or in case of powerfailure.To protect the gas pressure regulator from externalinfluences, starting from a corrosivity category C5-M werecommend an epoxy resin coating.Epoxy resin coating in RAL colorsTypes of modelsOxygen version O2Hydrogen version H2(with helium leak test)The BV breather valve is used as for securing the installationroom against inadmissible escape of gas from diaphragmcomparator compartments of safety shut-off valves. In case ofa defect, the impermissible escape of gas into the surroundingatmosphere is limited to a maximum of 30l/h (air).It also serves as a substitute for an expensive and complexinstallation of breather lines.(Option not available for hydrogen version H2)BV breather valve BV breather valveDesignExample:Checking the gas velocitiesw = 380 ∙ Q n / (DN² ∙ p abs )Note: The factor 380 refers to an operating gas temperature fromapprox. 15°C to 20°C. For other temperatures, the velocity must be corrected as follows: w corr = w ∙ (t gas + 273.15) / 290Recommended max. gas velocity at the inlet flange:50 - 70 m/s Lower value for redirections upstream of the SSVInlet and outlet nominal width of the pipeline according to the selected device: 25 mm Q n = 70m³/h p u / (p d ) = 5 bar w u = 380 ∙ 70 / (25² ∙ 6) = 7.1 m/sDetermining the upper response pressureOutlet pressure P d(mbar)Upper response pressure W dso≤200P d +100 mbar >200 - ≤800P d x 1.5>800 - ≤1600P d x 1.3>1600P d +500 mbarPressure loss formulaCalculation pressure absolute (p u +1 bar)= p u,absΔp = Q nK Gx1000p u,abs2Properties of Gases• for natural gas (ρn = 0.83 kg/m³; t = 15°C)•f - natural gas conversion factor- LGas f Hs,n Gas f Hs,n [kWh/m³] [kWh/m³]Acetylene 0.84 16.25 Sewage gas 0.84 Ammonia 1.04 4.83 Carbon monoxide 0.81 3.51Butane 0.55 37.23 Carbon dioxide 0.65 -Chlorine 0.51 - Air 0.80 -Landfill gas approx. 0.80 Methane 1.08 11.06Natural gas L 1.00 9.77 Propane 0.64 28.03Natural gas H 1.03 11.45 Oxygen 0.76 -E thane 0.78 19.55 Sulphur dioxide 0.53 -E thylene 0.97 16.516 Nitrogen 0.81 -Mine gas (30% CH4) 0.86 Hydrogen 3.04 13.43Helium 2.15 -Order DataSafety shut-off S50/Rp1“/MD-R/left/BV/N/H/WAZ/SoIn every selection group, only one option can be selected in each case.............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. ............................................................................. .............................................................................If you want to know more about solutions from MEDENUS for the gas industry, please contact your local contact person or go to our internet site at www.medenus.de Trade representation worldwide medenus.de/de/kontakt.htmlManagementALEXANDER CHRISTIANI Phone: +49 (0) 2761 / 82788-18Mail:***********************Head of Sales & Marketing FRANZ FEICHTNERPhone: +49 (0) 2761 / 82788-26Mobile phone: +49 (0) 151 / 51002711Mail:**********************Technical Inside Sales Department MINDAUGAS PECKAITISPhone: +49 (0) 2761 / 82788-23Mail:**********************Inside Sales Department SEBASTIAN HUCKESTEINPhone: +49 (0) 2761 / 82788-11Mail:***********************MEDENuSGas-Druckregeltechnik GmbHIm Langen Feld 3D-57462 Olpe Phone: +49 (0)2761 82788-0Fax: +49 (0)2761 82788-9Mail:***************Internet: www.medenus.deInside Sales Department STEFANIE MÜLLERPhone: +49 (0) 2761 / 82788-13Mail:********************Head of Inside Sales Department MANUEL SCHEPPPhone: +49 (0) 2761 / 82788-20Mobile phone: +49 (0) 170 / 6355309Mail:*******************Notes .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. .............................................................................. ..............................................................................Deutsch:http://medenus.de/files/upload/downloads/S50/Pi_S50_de.pdfEnglish:http://medenus.de/files/upload/downloads/S50/Pi_S50_en.pdfIn the download area of our homepage, this document is available in different languages. You can use the following QR codes and links to go directly to this document in your language.MEDENuS Gas-Druckregeltechnik GmbH Phone +49 (0)2761 82788-0Fax +49 (0)2761 82788-9Im Langen Feld 3 / D-57462 Olpe***************www.medenus.de。
Lectrosonics HHa系列手持传输器快速入门指南说明书
Q uick S tart G uideFill in for your records: Serial Number:Purchase Date:This guide is intended to assist with initial setup and operation of your Lectrosonics product.For a detailed user manual, down-load the most current version at: /manualsHandheld TransmitterHHa, HHa-941, HHa/E01, HHa/E02,HHa/EO6, HHa/XDigital Hybrid Wireless®US Patent 7,225,13514 October 2019Capsule and Battery InstallationA common threaded mount allows the use of a variety of different capsules fromdifferent manufacturers. Capsules are attached with a right-hand threadA mic capsule isthreaded onto the bodyof the transmitter in thedirection shown.Do not overtighten it.The lower housing opensby rotating it in the directionshown. After the threads aredisengaged, pull the housingdownward until it engages thedetent that holds it open.The threaded interface is a 1.25”opening with 28 threads per inch andthree contact ringsTo remove the windscreenfrom the mic capsule, lineup the blue wrench (thatwas included with yourunit) with the flat notcheson the lower threaded areaof mic capsule.To remove the batteries, pull the eject leveroutward. the battery tips will move outward,making them easier to grasp.To insert batteries, closethe eject lever and insertthe upper contactsfirst (closest to the miccapsule). Polarity ismarked on the label inthe bottom of the batterycompartment.Do not touch the contacts between the mic capsuleand transmitter body. When necessary, the contactscan be cleaned with a cotton swab and alcohol.LECTROSONICS, INC. 2 3Controls and Functions UP/DOWN Buttons for Menu Item SelectionPower ButtonModulation LEDsEnter Menu and Select ItemPrevious ScreenSide ButtonSetup SwitchPowering OnPress and hold the Power Buttonfor several seconds until a countdown on the LCD is completed. The countdown from 1 through 3 will appear on theLCD, followed by a display of the model, firmware version, frequency block and compatibility mode.When you release the button, the unit will be operational with the RF output turned on and the Main Window displayed.The Main WindowNOTE: If the Power Button i s released before the countdown iscompleted, the unit will boot up in the “standby” mode with the RF output turned off.Powering OffPress and hold the Power Button for several seconds and observe the count-down on the LCD. The countdown on the LCD will progress from 3 to 1 and the power will then be turned off. This can be done from any menu or screen.NOTE: If the Power Button is released before the countdown iscompleted, the unitwill remain turned on and the LCD willreturn to the same screen or menu that was displayed previously.Standby ModeA brief push of the Power Button turns the unit on and places it into a “standby” mode (not transmitting). This allows the transmitter to be set up without the risk of creating interference for other wireless systems that are operating in the vicinity.A notice will appear briefly confirming that the RF output of the transmitter is turned off, followed by the Main Window. A symbol will blink as a reminder that the RF output is turned off.SymbolPower MenuWith the unit turned on, a brief push of the Power Button will reveal a menu al-lowing you to choose between Resume , Pwr Off, Rf On?, and Backlit . Use the UP/DOWN buttons to select one of these menu items, then press the MENU/SEL button to confirm this action.Continued on pg 4.IR Sync Port• Resume: Continue operating in the same condition as before.• Pwr Off?: Turns off the transmitter.• Rf On?: Begin transmitting the RF signal.• Backlit: The LCD backlight is set to come on when any button onthe control panel is pressed, thenstay on for either 30 seconds or 5minutes, or to stay on all the time.. The unit can also be turned off from any menu or screen on the LCD by holding the power button in for the duration of the countdown.Battery ConditionAn icon on the Main Window indicates the remaining power of the transmitter batteries. This battery gauge is most accurate with the typical voltage drop across the life of alkaline and dry cell lithium batteries.Rechargeable batteries give little or no warning when nearing depletion. If you use rechargeable batteries in the HHa, we recommend trying fully charged batteries first, noting the length of time that the batteries will run the unit, andin the future using somewhat less than that time to determine when the battery needs to be replaced. The Venue and other receivers from Lectrosonics offer a timer function to assist in this process. Menus and Screens The Main Window displays the following information:Hex Code forOperating Icon indicates whether RFoutput is turned on or off in MHzside button1) Press the MENU/SEL button toenter the setup menu. Use the UP/DOWN buttons to highlight themenu item.2) Press the MENU/SEL button to en-ter the setup screen for that item.Use the UP/DOWN buttons toselect the desired value or mode.3) Press the MENU/SEL button tosave this setting and return to theprevious screen.4) Press the BACK button to return tothe Main Window.GainThis setting is very important since it will determine the audio signal to noise ratio and dynamic range that the wireless system will deliver. Gain must be set according to the individual voice, the mic capsule in use and the handling tech-nique of the user. LEDs in the control panel facilitate accurate gain adjustment.IMPORTANT: See the sectionAbout Setting Audio Gain onpage 6 for details.Freq.is normally determinedusing the scanningfunction in the receiveror with coordinationsoftware. The frequency is shown on the transmitter LCD display in MHz and with a hexadecimal code that is used on most Lectrosonics receivers.LECTROSONICS, INC.45ProgSwThe Programmable Switch on the housing can be set to Talkback, Power, Cough or a Mute function, or be bypassed (none).RolloffA sharp low frequencyrolloff filter protectsagainst breath popsand can be used toadjust the frequencyresponse to suitpersonal preferences. The slope istypically 36 dB/octave and varies slightly as the turnover point is selected.CompatThe HHa can be used with earlier Lec-trosonics wireless and IFB systems and systems from other manufacturers by selecting the correct Compatibility Mode . The receiver must be set to the same mode .The available modes are as follows:• Nu Hybrid: Digital Hybrid receivers • Mode 3: (other brand contact the factory)• IFB Mode: Lectrosonics IFB receiv-ersNOTE: If your Lectrosonics receiver does not have Nu Hybrid mode, set thereceiver to Euro Digital Hybrid Wireless® (EU Dig. Hybrid).StepSizThe frequency can be adjusted in 100 kHz or 25 kHz steps to match the receiver. 100 kHz is the standard increment forLectrosonics wireless systems, but 25 kHz increments may be needed for use with systems from other manufacturers or when frequency coordination requires it.The Hex Code on the Main Screen will be smaller in the 25 kHz mode and a fraction will appear next to the characters if a frequency in between even 100 kHz steps is selected.modeTxPowerOutput power can be set to 100 mW to extend operating range (whichcan also suppress noise and dropouts to some extent) or set to50 mW to extend the operating life of the batteries. US: Selectable 25 or 100 mW 941: Selectable 50 or 100 mW E01: Selectable 25 or 50 mW E02: 10 mWE06: Selectable 50 or 100 mW EIRPX:Selectable 50 or 100 mWPhaseThe phase (polarity) of the audio can be inverted to match other microphone capsules as needed.LECTROSONICS, INC.6Rf On?The transmitter output can be switched on or off with this menu item. This isuseful, for example, when the transmitter is in the “standby” mode during setup, allowing it to be turned on for normal operation without having to cycle thepower.This menu item can also be used to change the transmitter to the “standby” mode with the RF output turned off for additional setup.DefaultThe default setting simple returns the transmitter back to the factory settings and any of the menu items can be read-justed from that default point.Input Gain AdjustmentThe two bicolor Modulation LEDs (lo-cated at the bottom of the control panel) provide a visual indication of the audio signal level entering the transmitter.The modulation LEDs are oriented and labeled to be read when holding the mic capsule in front of your mouth.The gain should be set so that the -20 LED just turns red on the loudestpeak.The LEDs will glow either red or green to indicate modulation levels as shown inthe following table.It is best to go through the following procedure with the transmitter in the “standby” mode so that no audio will enter the sound system, which could cause feedback.1) With fresh batteries in the trans-mitter, power the unit on into“standby” (no transmission) mode.2) Press the MENU/SEL button onceto enter the setup menu. Use the UP/DOWN buttons to select Gain . Press the MENU/SEL button again to enter the setup screen.3) Hold the microphone the way it willbe used in actual operation.4) Speak or sing at the same voicelevel that will actually be used dur-ing the program, while observing the modulation LEDs. Use the UP/DOWN buttons to adjust the gain until the –20 dB LED starts to flicker red and the –10 dB glows green.5) Once the audio gain has been set,the signal can be sent through the sound system for overall level adjustments, monitor settings, etc. To do this, the unit must be set to transmit (see Powering On and Off , and the Standby Mode on page 3).NOTE: Full modulation isachieved when the -20 LED first turns red. 30 dB of clean limiting is available above this point.Programmable Switch FunctionsA special button (the Side Button)on the outside of the housing can be configured to provide several different functions, or to be inoperative.The ProgSw on the control panel opens a setup screen to select the function of the Side Button .Side Button Functions:• TalkBack• Power• Cough• Push To Talk• Mute• (none)The ProgSw menu provides a scrollable list of the available functions. Us the UP/ DOWN arrows to highlight the desired function and press BACK or MENU/SEL to select it and return to the main menu.Press theProgrammable Switchor select ProgSw onthe main menu.Side ButtonSetup SwitchTalkback is a “push to talk” function that is active only while the button is pressed. The talkback function provides a com-munication channel when used with a receiver equipped with this function, such as a Venue Wideband receiver with firmware Ver. 5.2 or higher. When pressed and held in, the side buttonre-directs the audio output to a differ-ent audio channel on the receiver. As soon as the switch is released, audio is returned to the program channel.NOTE: The Talkback functionis only available in the DigitalHybrid compatibility mode. Anerror message will appear ifTalkback is selected while inanother mode.Power turns the power on and off.Hold the button in until the countdown sequence from 3 to 1 is completed. The power will then be turned off.Cough is a momentary mute switch. Au-dio is muted while the button is held in. Push to Talk is a momentary talk switch. Audio is transmitted while the button is held in (opposite of cough).Mute is a “push on/push” off function that toggles on and off each time the Side Button is pressed. The mute func-tion defeats the audio in the transmitter, so it works in all compatibility modes and with all receivers.(none) disables the switch.For detailed information on setting up the Talkback function and the Venue receiver, refer to the Installa-tion Guide for the Venue Wideband Receiver.Main Window Displays for Mute and Talkback FunctionsThe function of the SideButton is displayed inthe LCD Main Window.When the Side Buttonis pressed, the functionwill be active and theLCD will display anindication.7LIMITED ONE YEAR WARRANTYThe equipment is warranted for one year from date of purchase against defects in materials or workmanship provided it was purchased from an authorized dealer. This warranty does not cover equipment which has been abused or damaged by careless handling or shipping. This warranty does not apply to used or demonstrator equipment.Should any defect develop, Lectrosonics, Inc. will, at our option, repair or replace any defective parts without charge for either parts or labor. If Lectrosonics, Inc. cannot correct the defect in your equipment, it will be replaced at no charge with a similar new item. Lectrosonics, Inc. will pay for the cost of returning your equipment to you.This warranty applies only to items returned to Lectrosonics, Inc. or an authorized dealer, shipping costs prepaid, within one year from the date of purchase.This Limited Warranty is governed by the laws of the State of New Mexico. It states the entire liablility of Lectrosonics Inc. and the entire remedy of the purchaser for any breach of warranty as outlined above. NEITHER LECTROSONICS, INC. NOR ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT SHALL BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, CONSEQUENTIAL, OR INCIDENTAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THIS EQUIPMENT EVEN IF LECTROSONICS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF LECTROSONICS, INC. EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE EQUIPMENT.This warranty gives you specific legal rights. You may have additional legal rights which vary from state to state.®。
SC50560中文资料
SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-211INFRARED REMOTE CONTROLTRANSMITTERDESCRIPTIONThe SC50560is a remote control transmitter utilizing CMOStechnology housed in a20-pin DIP or SO package.A4x8key matrixand extension bit inputs allow the transmission of up to256instructions.The transmission code consists of16bits code(8bitscustom code and8bits data code)and a leader code.Pin assignments and application circuit of SC50560are optimizedfor easy PCB layout and cost saving advantage for remote controlapplications.FEATURES*CMOS technology*Low power consumption*Least external components*LED power dissipation is less during the transmission ofinstructionsORDERING INFORMATIONSC50560SC50560SDIP-20PackageSOP-20PackageAPPLICATIONS PIN CONFIGURATION*Audio Equipment*Television*Video Cassette Recorder*Air ConditionVssTESTSELOSCIOSCOCSKIO0KO7KO6KO5KO4KO3KO2KO1KO0D OUTV DDKIO1KIO2KIO3SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-212BLOCKDIAGRAMKIO0KIO1KIO2KIO3VSSVDDCSOSCOOSCIDOUTSELABSOLUTE MAXIMUM RATINGS (Tamb=25°C)Characteristic Symbol ValueUnit Supply Voltage V CC-0.3~5.5VInput Voltage V IN Vss-0.3V~V DD+0.3V VOutput Voltage V OUT Vss≤Vo≤V DD VOperating Temperature Topr-20~70°CStorage Temperature Tstg-40~+125°CELECTRICAL CHARACTERISTICS(Tamb=25°C, V DD=3.0V,Vss=0,Unless otherwise specified) Parameter SymbolTestConditionsMinTyp MaxUnitSupply Voltage V DD Fosc=455KHz 2.0 3.0 4.0VOperating Current I OP Fosc=455KHz0.120.3mAStand-by Current I SBOSCO=V DD KIO0~KIO3=V DDTEST=Vss SEL=Vss0.11µAHigh level Output Current(Dout)I OH V OH=2V-1.0-13mAI OL0.5 1.2Low Level Output Current(Dout,KO0~KO7)I KO0~KO7V OL=0.9V4.55.3mAHigh Level Input Voltage(CS)(KIO0~KIO3)V IH V DD=3.0V0.7V DD V DD VLow Level Input Voltage(CS)(KIO0~KIO3)V IL V DD=3.0V00.3V DD VInput Pull-High Resistance(KIO0~KIO3)R IN V DD=3.0V557085kΩSilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-213PIN DESCRIPTIONPin No. Pin Name Input/output Description1V SS--Negative Power Supply2TEST I Test Pin.This pin is normally connected to VSS.3SEL I Select Pin for SC50560-001/003.4OSCI I Oscillation Input Pin5OSCO O Oscillation Output Pin6CS I Code Select Pin7~10KIO0~KIO3I/O Input/Output Pins18~11KO0~KO7O Scan Output Pins19Dout O Output Pin20V DD--Positive PowerSupplyFUNCTIONAL DESCRIPTIONSC50560is capable of transmitting up to256different instructions and8bits custom codes using a16-bit PCM Code with a leader code.Furthermore,oscillation is normally stopped when there is no operating,thereby,lower power dissipation.1. TRANSMISSION CODESC50560transmission code consists of a leader code,8bits custom code(C0to C7)followed by a sync.bit and8bits data code(D0to D7)followed another sync.bit.The custom and the data codes are separated by a separator.Please refer to the diagram below:Sync.Bit Sync.BitFigure1.SC50560Transmission Code FormatOne transmission Code Word consists of a19-bit pulse(that is the leader pulse plus the16bits code)and the separator.It is transferred in a63.4ms for as long as the key is depressed.Please refer to the diagram below:SEPARATOR8BITS CUSTOM CODE8BITS DATA CODEFigure2.SC50560Detailed Code Word FormatSilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-214LEADER CODEThe leader code is located at the beginning of the transmission code and is made up of8.4ms HIGH&4.2ms LOW pulse and is modulated in38KHz providing easy identification of the reception code head bit at the receiver.CUSTOM CODECustom Code may be selected by connection CS Input with Scan Output(KO0to KO4).An example of a custom code selection is shown in the diagram below.Custom Code101010C6C7Figure3.custom Code Selection ExampleDATA CODED0to D7of the transmission code are the data code bits.When CS Input and the Scan Output(KO5toKO7)are connected,data bits—D5to D7becomes the system extended code bits.An example of theExtended code Bits Selection is given in the diagram below:Data Code D5 D6 D7SW=OFF100SW=ON101 Figure4.Extended Code Selection2. SEPARATORThe separator demarcates the custom code and the data code.It consists of a4.2ms LOW pulse interval and can be determined at the receiver so theat any interference with other remote control system may be avoided. Please refer to Figure2.SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2153. CARRIERThe carrier of the transmission signal is38KHz and one pulse width is0.52ms.Therefor,with the exception ofthe leader code,there are twenty38KHz clock in one pulse width.Please refer to the diagram below.Figure5.Transmission Signal Carrier Diagram4. KEY INPUTBy connecting the input pins–KI0to KI3and scan output pins–KO0to KO7(also known as the Standard Keys),a4x8key matrix may be formed.Likewise,a maximum of256instructions may be provided by connecting the inputCS with the scan output–KO0to KO7(also known as the Extended Keys).When two or more standard keys are pressed,the transmission output Dout is kept at LOW and no transmission code is outputted.Please refer to thetables below.DataKey InputD0 D1KI000KI110KI201KI311Data Data Scan OutputD2 D3 D4CS InputD5 D6 D7 KO0000KO51----KO1100KO6--1--KO2010KO7----1KO3110KO4001KO5101KO6011KO7111SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2165. Oscillation CircuitThe oscillation circuit may be constructed by connected aceramic resonator between the OSCI and OSCO.Pleaserefer to the diagram right.When the references signal is setto455KHz the carrier can be set at38KHz.When no keyinput is pressed,the oscillation circuit is normally stopped,thereby,lower power dissipation.Figure6.Oscillation Circuit6. CODE FORMAT MODESSC50560code format comes in three modes:001,002and003.Please refer to the diagram below:SC50560 Version DescriptionMinimum Number of WordsTransmittedSC50560-001Mode A Code Format:Custom Code Bit5--C5=0,SEL is connected to V DD1word SC50560-002Mode A&B Code Formats3wordsSC50560-003Mode A Code Format:Custom Code Bit5--C5=1,When SEL is connected to Vss-----Both SC50560-001and SC50560-002make use of the same operation when the input from terminal CS andthe scan output(KO0to KO4)are connected to make the custom code selection with the exception ofthe numberof word transmitted.Please refer to the table above:MODE AThe diagram below gives us the transmission code format for Mode A.One Code Word consists of the Leader Code,8bits Custom Code followed by a sync.bit,Separator and8bits Data Code followed by another sync.bit. Please refer to the diagram below.Sync.Bit Sync.BitFigure7.Mode A Code FormatEach Code Bit may either be“0”or“1”.Please refer to the diagram below.SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-217Bit"0"Bit"1"Figure8.Mode A Bit“0”&“1”WaveformMODE BThe diagram below gives us the transmission code format for Mode B.Under this mode,the custom codes arenot selected,therefore the transmission code only consists of the6bits data code followed by a sync.bit.Pleaserefer to the diagram below:SYNCD0D1D2D3D4D5Data CodeFigure9.Mode B Code FormatAtransmission Code Bit may either be“0”or“1”.Please refer to the diagram below:Bit"0"Bit"1"Figure10.Mode B Bit“0”&“1”Waveform DiagramUnder Mode B,a maximum of32different instructions may be provided simply by connecting the inputs KI0toKI3with the Scan Outputs KO0to KO7,thereby constructing a4x8key matrix.When two or more keys are pressedat the same time,the transmission output Dout is set to and the no transmission occurs.Please refer to the table below.KO0 KO1 KO2 KO3 KO4 KO5 KO6 KO7 KI0 0004080C10*14*18*1C*KI1 010509*0D*11*15*19*1D*KI2 02060A*0E*12*16*1A*1E*KI3 03070B*0F*13*17*1B*1F* NOTE:*=Output of a five-word transmission code.SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-218APPLICATION CIRCUIT1. For 01 and 03 VersionsSettings for DataSilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2192. Extended CodesCustom Code SettingStandard Code Extended CodeKI0KI1KI2KI3KI0KI1KI2KI3 KO000010203KO104050607KO208090A0FKO30C0D0E0BKO410111213Not UsedKO51415161734353637KO618191A1B58605A5BKO71C1D1E1F9C8D9E9FSilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-21103. Double Key OperationCustom Code Setting Double KeySilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-21114. No Leader Code and Custom CodeSilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2112CHIP TOPOGRAPHY1716151413121110987654321201918Size:1.40x1.21mm2PAD COORDINATES (Unit:µm)No. Symbol X Y No. Symbol X Y1P1-579.10-35.5011P11579.00142.30 2P2-579.10-184.5012P12579.00291.30 3P3-579.10-333.5013P13579.00440.30 4P4-579.10-482.5014P14270.80482.50 5P5-141.60-482.5015P15121.80482.50 6P68.3-482.5016P16-27.20482.50 7P7421.60-482.5017P17-176.20482.50 8P8579.00-304.7018P18-579.10411.50 9P9579.10-155.7019P19-579.10262.50 10P10579.10-6.7020P20-579.10113.50 Note:The original point of the coordinate is the die center.SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2113PCB WIRE LAYOUT SCHEMATIC:layout separated or overstriking ground line.The above IC only use to hint,not to specified.Note:*In wire layout,the power filter capacitor should near to IC.*In wire layout,should avoid power line and ground line too long.*Recommended infrared transmit unit and IC ground line should layout separated,or overstriking lines.*The emitter of triode connect1¡resistor at least.*Recommended triode use9014.SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2114SilanSemiconductorsSC50560HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTDRev:2.32002-03-2115AttachRevision HistoryData REV Description Page 2000.12.31 2.0Change name of company in page footer2002.01.04 2.1Delete“or floating“in“6.code format modes”6 2002.02.28 2.2Modify the“Pin configuration“Modify the“Application circuit”Add the“PCB wire layout schematic”Modify the“Package outline”18-111314 2002.03.21 2.3Modify the“figure3”and“figure4”4。
MAV-11SM中文资料
ABSOLUTE MAXIMUM RATING7
DC POWER at Pin 3
THERMAL RESISTANCE 6
θ jc °C/W 115 105 115 100 120 120 140 110 100 110 95 85 125
CAPD DATA
(see RF/IF Designer Handbook)
2000 — 11.0 10.5 — 11.0 11.0 — — 10.0** 10.0** — 6.5** —
note 5 note 1 Typ. Output Input (1 dB (no Comp.) damage) MIN. 13.0 8.5 8.0 7.0 9.0 8.5 19.0 12.5 7.5 7.5 7.0 5.5 9.0 +1.5 +4.5 +10.0 +12.5 +2.0 +5.5 +12.5 +1.5 +4.5 +10.0 +11.5 +18.0 +17.5 +13 +13 +13 +13 +13 +13 +13 +13 +13 +13 +13 +20 +13
cb cb cb cb
3.0 +14.5 5.0 +19.0 3.3 +27.0 5.5 +14.0 6.5 +17.0 6.0 +23.0 7.0 +24.5 6.5 +29.0 3.6 +30.0
WW107 cb WW107 cb WW107 cb RRR137 cb ቤተ መጻሕፍቲ ባይዱRR137 cb RRR137 cb RRR137 cb RRR137 cb RRR137 cb
美国海利威尔公司V15系列微型基本开关说明书
V15 SERIESMICRO SWITCH Standard Miniature Basic Switches004945Issue 12DESCRIPTIONHoneywell’s MICRO SWITCH V-Basic Standard Switch, V15 Series is anelectromechanical switch designed to provide outstanding value in a reliable global package. This switch is often ideal for “low-cost-of-failure” applications, where the cost is minimal to replace or service any failure related to the switch. With a wide variety of operating forces, and amperage ratings, the V15 is designed for numerous types of applications.Available in both pin plunger and levered styles, the V15 Series also offers a multitude of termination styles to fit almost any application.DIFFERENTIATION• Choice of actuation, termination, and operating characteristics that can allow for flexibility in numerous types of applications• With a broad current capacity, one switch package can control a wide range of electrical loadsAPPLICATIONS• Appliances • Furnaces• Gaming machines • Ice makers • Power washers • Vending machinesVALUE TO CUSTOMERS• Wide choice of electrical ratings: 0.1 A, 5 A, 10 A, 16 A, 22 A, 26 A • Certified for global use: UL/cUL, ENEC, CQC• Available with pin plungers or integral levers to meet multiple application and equipment requirementsFEATURES• Broad range of electrical loads: 0.1 A, 5 A, 10 A, 16 A, 22 A, 26 A • Long service life: over one million mechanical operations• Gold contacts are also available for controlling logic level/low energy circuits• World-wide package size acceptance • UL/CSA, cUL, ENEC, and CQC approvals• Variants with cadmium-free and optimized contacts availableHoneywell offers a wide range of MICRO SWITCHthe large basic switches,Sensing and Internet of Things 3V15S05 PRODUCT NOMENCLATURE V15Switch TypeTemperatureGradeSLeverPositionElectrical Rating05V15 Series Standard Basic SwitchTerminal TypeCircuit Code—ZAOperating Force(at pin plunger max)200Mounting HolesKALever Type06Special DesignatorC—Housing Type1V15T10 PRODUCT NOMENCLATUREV15Switch TypeTemperatureGradeTLever PositionElectrical Rating10V15 Series Standard Basic SwitchTerminal TypeCircuit Code—ZAOperating Force(at pin plunger max)200Mounting HolesKALever Type06A special designator letter is used only when there is a special modificationto the switch.Review Product Specification to determine the exact differences. Below is an example.Special DesignatorC—Housing Type1V15H16/T16/T22/H22/T26 PRODUCT NOMENCLATURE V15Switch TypeTemperatureGradeHLever PositionElectrical Rating16V15 Series Standard Basic SwitchTerminal TypeCircuit Code—ZAOperating Force(at pin plunger max)200Mounting HolesKALever Type06Special DesignatorC—Housing Type1PinPlunger4 ShortStraightLeverStandardStraightLeverSensing and Internet of Things 5LongStraightLeverSimulatedRoller6 ShortRollerLeverSensing and Internet of Things 7RollerLever8 Sensing and Internet of Things 9MOUNTING DIMENSIONSFIGURE 1. V15 SERIES STANDARD SWITCH DIMENSIONSFIGURE 2. V15 SERIES METRIC MOUNTING HOLE DIMEN-SIONS FOR Ø 3 MM PINS OR SCREWSMetric mounting for Ø 3 mm pins or screws Ø 3,10 mm +0,10 mm/-0,05 mm 10,3 m m ±0,1 m m Ø 0.12 in +0.004 in/-0.002 in mounting holeFIGURE 3. V15 SERIES USA MOUNTING HOLE DIMENSIONS FOR #4 SCREWSUS mounting for #4 screws - K Designator Ø 2,90 mm +0,10 mm/-0,05 mm10,3 m m ±0,1 m m Ø 0.11 in +0.004 in/-0.002 in mounting holeFIGURE 4. V15 SERIES HOUSING DIMENSIONS10 Sensing and Internet of Things 1112 STANDARD LEVER OPTIONS • DIMENSIONSFIGURE 19. V15 SERIES A01/STRAIGHT SHORT LEV erFIGURE 20. V15 SERIES A02/STANDARD STRAIGHT LEVERFIGURE 21. V15 SERIES A03/LONG STRAIGHT LEVERFIGURE 22. V15 SERIES A04/SIMULATED ROLLER LEVERFIGURE 23. V15 SERIES A05/SHORT ROLLER LEVERFIGURE 24. V15 SERIES A06/ROLLER LEVERNOTE: These dimensions apply for the “A” lever position. For the “B” leverposition, please add 5,7 mm [0.224 in].Position APosition BWARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicablewarranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application.Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing.However, Honeywell assumes no responsibility for its use.004945-12-EN | 12 | 08/20© 2019 Honeywell International Inc. All rights reserved.m WARNINGIMPROPER INSTALLATION• Consult with local safety agenciesand their requirements whendesigning a machine-control link, interface and all control elements that affect safety.• Strictly adhere to all installationinstructions. Failure to comply with theseinstructions could result in death or serious injury.m WARNINGMISUSE OFDOCUMENTATION•The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.•Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.Failure to comply with theseinstructions could result in death or serious injury.HoneywellSensing and Internet of Things 830 East Arapaho Road Richardson, TX FOR MORE INFORMATIONHoneywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit or call:USA/Canada +302 613 4491Latin America +1 305 805 8188Europe +44 1344 238258Japan +81 (0) 3-6730-7152Singapore +65 6355 2828Greater China+86 4006396841RELATED DOCUMENTATIONThe following associated literature is available on the Honeywell web site at :• Installation instructions• Product part listing/nomenclature tree• Product application-specific information– Application note: Electronic sensorsand eectromechanical switches in valves and flow meters – Application note: Electronic sensorsand MICRO SWITCH switches in industrial air compressors – Application note: Sensors andswitches for potential HVAC/R applications – Application note: Sensors andswitches for valve monitors and valve indicators – Application note: Sensors andswitches in sanitary valves – Case study: Switching it up– Technical bulletin: Applying precision switches。
SC52-11EWA, 规格书,Datasheet 资料
芯天下--/
SPEC NO: DSAC0696 APPROVED: WYNEC
REV NO: V.11 CHECKED: Joe Lee
DATE: JAN/25/2011 DRAWN: D.M.Su
PAGE: 5 OF 6 ERP: 1301001025
芯天下--/
PACKING & LABEL SPECIFICATIONS
SC52-11EWA
SPEC NO: DSAC0696 APPROVED: WYNEC
REV NO: V.11 CHECKED: Joe Lee
DATE: JAN/25/2011 DRAWN: D.M.Su
PAGE: 4 OF 6 ERP: 1301001025
SPEC NO: DSAC0696 APPROVED: WYNEC
REV NO: V.11 CHECKED: Joe Lee
DATE: JAN/25/2011 DRAWN: D.M.Su
PAGE: 6 OF 6 ERP: 1301001025
芯天下--/
Note: 1. Luminous intensity/ luminous Flux: +/-15%.
Electrical / Optical Characteristics at TA=25°C
Symbol λpeak λD [1] Δλ1/2 C VF [2] IR Parameter Peak Wavelength Dominant Wavelength Spectral Line Half-width Capacitance Forward Voltage Reverse Current Device High Efficiency Red High Efficiency Red High Efficiency Red High Efficiency Red High Efficiency Red High Efficiency Red Typ. 627 625 45 15 2.0 2.5 10 Max. Units nm nm nm pF V uA Test Conditions IF=20mA IF=20mA IF=20mA VF=0V;f=1MHz IF=20mA VR=5V
SC A规格书v
OUT0 OUT1 OUT2
OUT3
OUT4
VDD 10K 10K 10K 10K 10K RU0 RU1 RU2 RU3 RU4
3.2.2 模拟电压输出
VDD
5.1K
SDA
RU
SCL
OUT0
AO
SC05A
OUT1
R1
1.3K
SOP16
OUT2
R2
3.3K
OUT3
R3
7.5K
OUT4
R4
20K
Dimensions In Millimeters
Min
Nom
Max
1.30
1.50
1.70
0.06
0.16
0.26
0.30
0.40
0.55
0.15
0.25
0.35
9.70
10.00
10.30
3.75
3.95
4.15
--
1.27
--
5.70
6.00
6.30
0.45
0.65
0.85
0°
--
8°
Dimensions In Inches
1.2 特征
◇ 5 个完全独立的触摸感应按键 ◇ 保持自动校正,无需外部干预 ◇ 按键输出经过完全消抖处理 ◇ 多接口 – I2C 串行接口 / 并行一对一输出 ◇ 所有按键共用一个灵敏度电容 ◇ 感应线长度不同不会导致灵敏度不同 ◇ 2.5V ~ 6.0V 工作电压 ◇ 符合 RoHS 指令的环保 SOP16 封装
1.3 应用
◇ 替代机械开关 ◇ 家庭应用(电视机, 显示器键盘) ◇ 玩具和互动游戏的人机接口 ◇ 门禁按键 ◇ 灯控开关 ◇ 密封键盘面板
施耐德 APC SMV Series 750 1000 1500 2000 3000 VA说明书
SA VE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation and maintenance of the UPS and batteries.Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this document or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.The addition of this symbol to either a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.NOTICE is used to address practices not related to physical injury.Important Safety Messages<18 kg <40 lb18-32 kg >55 kg >120 lb32-55 kg 70-120 lbProduct Handling Guidelines40-70 lbNOTICEFor Professional Business Applications – Not For Consumer UseEasy UPS SMV Series 750, 1000, 1500, 2000, 3000VA2ŸAdhere to all national and local electrical codes.ŸThis UPS is intended for indoor use only. To prevent the risk of fire or electric shock, install in atemperature and humidity controlled indoor area, free of conductive contaminants.ŸMains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.ŸUPS must be connected to an earthed mains socket outlet.ŸCAUTION This UPS is designed to satisfy all of requirement of PCs only.ŸCAUTION Risk of electric shock, do not remove the chassis cover. Servicing should be performed by Qualified Engineer.ŸServicing of user replaceable batteries should be performed or supervised by personnelknowledgeable about batteries and required precautions. In this case batteries are not user replaceable.ŸWhen replacing battery the UPS must be OFF, and its AC inlet unplugged.ŸCAUTION Do not dispose of batteries in a fire. The batteries may explode.ŸCAUTION Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.ŸDo not open or mutilate batteries. They contain an electrolyte that is toxic and harmful to the skin and eyes.ŸCAUTION A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries.a. Remove watches, rings or other metal objects.b. Use tools with insulated handles.c. Wear rubber gloves and boots.d. Do not lay tools or metal parts on top of batteries.e. Disconnect the charging source prior to connecting or disconnecting battery terminals.f. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.Safety and General InformationGeneral safetyBattery safetyŸCAUTION The UPS contains internal batteries and may present a shock hazard even whendisconnected from AC power.ŸCAUTION Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test before touching.Radio Frequency WarningThis is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.InventorySoftware, User documentation3a)IEC C14 plug to C13 plugc)SCHUKO plug to IEC C19 plugb)SCHUKO plug to IEC C13 plugModel SMV750CAI SMV1000CAI SMV1500CAI SMV2000CAI Cable a x 1b x 1SMV3000CAIa x 1c x 1USB cableEasy UPS SMV Series 750, 1000, 1500, 2000, 3000VAOptionalProduct FeaturesON/OFF button RS-232USB portFan /ventilation hole Battery connector AC Inlet4FuseBattery backup outlets with surge protection Output breaker (only for SMV3000CAI)Intelligent Slot Dry contactEasy UPS SMV Series 750, 1000, 1500, 2000, 3000VAFront panel display5Easy UPS SMV Series 750, 1000, 1500, 2000, 3000VA1. Inspection:Ÿ UPS MUST be installed indoor with controlled environment free of excessive dust, corrosive air or conductive dust.Ÿ Do NOT install in outdoor.Ÿ Keep out of direct sun light, water and heat sources Ÿ Place the unit on the stable floor.2. Connect the battery by pulling the battery handle up, and then pushing it into the unit.Ÿ The battery connector is located on the rear panel.-Connect prior to operation.-Disconnect prior to transportation. Turn OFF the UPS and remove input power cable before disconnecting the battery connector.3.Connect equipment to the UPS. Avoid using extension cords. ŸDo NOT connect printers, heaters, or copiers to the UPS.ŸDuring a power outage or other AC problems, the Battery Backup outlets receive power for a limited time from the Easy UPS.4. Plug the Easy UPS power cord directly into a wall outlet, not into a surge protector or power strip.5 Press the ON/OFF button to turn on the unit..ŸThe Easy UPS should charge the battery for at least 8 hours to ensure sufficient runtime.Ÿ Press On / OFF button in 1~3 seconds. The buzzer sound confirms that the Easy UPS is on and provide power to outlets.6 Cold start the UPS.ŸUse cold start feature to supply power to connected equipment from the UPS batteries when the UPS is off and there is no power utility.7 Connect and install management software.ŸEasy UPS is provided with management software for unattended operating system shutdown, UPS monitoring, and UPS settings.ŸRefer to for more information.8When UPS is operating in one of three conditions shown as below, the dry contact interface will be . activated. The diagram is shown in Pic.1.ŸWhen UPS detects the battery failure, PIN1-4 of a dry contact will be activated. ŸWhen UPS is operating in Backup mode , PIN2-4 of a dry contact will be activated.ŸWhen UPS is operating in AC mode ,.PIN3-4 of a dry contact will be activatedWhen UPS is operating in…Activate1. AC modePIN3-42. Backup modePIN2-43. Standby modeN/A4. AC mode and Battery weakPIN1-4 & PIN3-45. Standby mode and Battery weakPIN1-4(Pic. 1)Before installing the UPS, ensure the input breaker on the UPS upstream is Type C rated at 16A.Installation and Power OnAudible Indicators and Status IconsIf the Easy UPS…Possible cause...Beeps every 2 seconds.Easy UPS is running on battery. You should consider saving any work in progress.Continuous Beeping.Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system.Continuous tone with illuminated.Battery Backup outputs are overloaded.Continuous tone with illuminated.a. Press ON/OFF button for 1-3 seconds to mute the alarm.b. Continuous tone will persist until battery LOW.(<11Vdc each BATT)Beeps every 4 seconds with illuminated.The battery is near the end of useful life or damaged.: Fan fault detected : Inverter short : Inverter over voltage6Easy UPS SMV Series 750, 1000, 1500, 2000, 3000VABatteryEnvironment V oltageUPS Capacity (total)Rated V oltage Transfer time ModelPhysicalWaveformType(maintenance-free)Net Weight (kg)Dimension (DxWxH, mm)Gross Weight (kg)Enclosure typeV oltage range SMV750CAI220/230/240V AC165~290Vac ±5Vac165~295Vac ±8Vac8A 8A12A 20A25A 230V ACTypical 2-6 ms, 12ms max.12V/7Ah x 212V/7Ah x 212V/10Ah x 212V/7Ah x 412V/9Ah x 4410 x 160 x 220455 x 180 x 240Less than 45 dBIP20Noise levelIP RatingSMV1000CAISMV1500CAISMV2000CAI SMV3000CAIFuseCharging time Packaging Dimension (DxWxH, mm)Operating temperature &Humidity750V A 1000V A 1500V A 2000V A 3000V A lead acidlead acid lead acid lead acidlead acid525W700W1050W 1400W2100WPure Sine Wave4-6 hours recover to 90% capacity 13.617.823.525.2508 x 272 x 339604 x 319 x 41416.620.7526.928.90-95 % RH @ 0-40°C (non-condensing)Frequency Range 45-65 Hz (auto sensing) ±1HzSpecificationsOutputInputTroubleshooting7 Easy UPS SMV Series 750, 1000, 1500, 2000, 3000VAIf the unit requires service, do not return it to the dealer. Follow these steps:1. Review the Troubleshooting section of the manual to eliminate common problems.2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support through the APC by Schneider Electric website, .a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit.b.Call SEIT Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).c. If the unit is under warranty, the repairs are free.d.Service procedures and returns may vary internationally. Refer to the APC by Schneider Electric website for country specific instructions.3. Pack the unit in the original packaging whenever possible to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty.4. Always DISCONNECT THE UPS BATTERIES before shipping. The United States Department of Transportation (DOT), and the International Air Transport Association (IATA) regulations require that UPS batteries be disconnected before shipping. The internal batteries may remain in the UPS.5. Write the RMA# provided by Customer Support on the outside of the package.6. Return the unit by insured, pre-paid carrier to the address provided by Customer SupportAPC by Schneider Electric IT Customer Support WorldwideWa rrantyRegister y our p roduct o n -line. h ttp ://wa r The standard warranty is two (2) years from the date of purchase. SEIT standard procedure is to replacethe original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative. SEIT will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground freight transportation costs to ship the replacement unit to the customer.For country specific customer support, go to the APC by Schneider Electric website, www .apc .com .EN 990-91267B05/2021© 2021 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.Service。
NES-50-12中文资料
SPECIFICATIONMODELDC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWEROUTPUTVOLTAGE ADJ. RANGELINE REGULATION Note.4LOAD REGULATION Note.5SETUP, RISE TIME HOLD TIME (Typ.)VOLTAGE RANGE FREQUENCY RANGEEFFICIENCY(Typ.)AC CURRENT (Typ.)INPUTINRUSH CURRENT (Typ.)LEAKAGE CURRENT SAFETY STANDARDS WORKING TEMP.WORKING HUMIDITYSTORAGE TEMP., HUMIDITYTEMP. COEFFICIENT VIBRATIONMTBFDIMENSION OTHERSNOTEPACKINGOVER LOAD12V 15V 24V 48V 4.2A 3.4A 2.2A 1.1A 0 ~ 4.2A 0 ~ 3.4A 0 ~ 2.2A 0 ~ 1.1A 51W 52.8W 52.8W 120mVp-p 150mVp-p 200mVp-p 240mVp-p 1.0%0.5%0.5%10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V 1.0%0.5%0.5%1.0%0.5%0.5%1.0%0.5%0.5%500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load 50ms/230VAC 10ms/115VAC at full load85 ~ 264VAC 120 ~ 370VDC47 ~ 63Hz 79%83%17.25 ~ 20.2586%87%27.6 ~ 32.4V 55.2 ~ 64.8V82%13.8 ~ 16.2V 1.1A/115VAC 0.65A/230VAC COLD START 45A <2mA / 240VAC110 ~ 150%rated output power5.75 ~6.75V Compliance to EN55022 (CISPR22) Class B -20 ~ +60(Refer to output load derating curve)20 ~ 90% RH non-condensing-40 ~ +85, 10 ~ 95% RH 0.03%/(0 ~ 45)10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes 374.2K hrs min. MIL-HDBK-217F (25)129*98*38mm (L*W*H)5V 10A 0 ~ 10A 50W50.4W 80mVp-p 2.0%0.5%0.5%NES-50-5NES-50-12NES-50-15NES-50-24NES-50-48OVER VOLTAGE HARMONIC CURRENT EMS IMMUNITYCompliance to EN61000-3-2,-3Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A 4.75 ~ 5.5VUniversal AC input/Full rangeProtections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test 2 years warrantyFeatures :RIPPLE & NOISE (max.)Note.2VOLTAGE TOLERANCE Note.3EMI CONDUCTION & RADIATION ENVIRONMENT SAFETY &EMC(Note 6)PROTECTIONWITHSTAND VOLTAGEISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVACI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.Protection type :Hiccup mode, recovers automatically after fault condition is removed Protection type : Shut down o/p voltage, re-power on to recover 0.41Kg; 45pcs/19.5Kg/1.24CUFTUL60950-1, CB(IEC60950-1)ApprovedMechanical SpecificationCase No. 903 Unit:mmBlock DiagramCIRCUIT DETECTION O.L.P.EMI FILTERRECTIFIERS&FILTERPOWER SWITCH-FILTER&RECTIFIERS+V -VI/PFGINGCONTROLO.V.P.Output Derating VS Input VoltageINPUT VOLTAGE (VAC) 60Hz8510095120115160140200180240220264L O A D (%)Ta=25901008070605040+V ADJ.AMBIENT TEMPERATURE ()L O A D (%)-2002010304020408060100605070fosc : 60KHz(HORIZONTAL)Derating Curve Terminal Pin. No AssignmentPin No.Pin No.12435Assignment Assignment DC OUTPUT -V DC OUTPUT +VFGAC/L AC/N 93.53.577323828.53-M33.59.5184.573.512985.533312-M33.5981206.518.558.29.54321122.57。
长江连接器A2011系列
Circuit 1
+0.05 Ø0.80-0.00 P.C.B LAYOUT
Ordering Information & Dimensions
PART NO.
A2011WV-2P A2011WV-3P A2011WV-4P A2011WV-5P A2011WV-6P A2011WV-7P A2011WV-8P A2011WV-9P A2011WV-10P A2011WV-11P A2011WV-12P A2011WV-13P A2011WV-14P A2011WV-15P
B±0.25
5.00±0.25
5.00±0.25
PIN 0.50 SQ
0.80
A2011WR
Reference Informations: *Material:Pin:Brass/Tin over Nickel Insulator:Nylon 66,UL94V-0 *Mates with CJT A2011 series Housing *Color:Black PIN 0.50 SQ
4.80±0.10
Circuit 1
3.30±0.10
Reference Informations: *Material:Pin:Brass/Tin over Nickel Solder Tabs: Brass/Tin over Nickel Insulator:Nylon 6T,UL94V-0 *Mates with CJT A2011 series Housing *Color:Ivory
Dimensions A B
2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 28.00 30.00 Unit: mm
Alsanfan HVLS 大气流扇产品介绍说明书
HVLS FAN INDUSTRY6BLADESIndustrial Ceiling FansHVLS FAN INDUSTRYHigh Volume Low Speed Fan (6 Blades)Fancy Fan (8 Blades)Mobil Pivot Fancy Fan (6 Blades)Pivot Farm HVLS Fan (6 Blades)15913 HVLS FAN INDUSTRYWith the aerodynamic fan blade design that our company developed and designed in the early 2000s, our company has become one of the few companies in the world. Alsanfan works with the leading university in our country in terms of product development and fan performance. We have also added ceiling fans that we have completed R & D activities to our production portfolio. The constant principle of our company has always been quality service, on time delivery and reasonable price.What are Industrial Ceiling Fans (HVLS Fan) ?Alsanfan HVLS ceiling fans offers an innovative product that reduces heating-cooling costs in large-volume, high-ce-ilinged spaces. Alsanfan is capable of activating a high volume of air with low speed. With this feature, homogenous tempreture is obtained from floor to ceiling distribution of air stratification in high ceiling areas.At the same time, air is sent to the employees at a low speed to provide evoparative cooling (fan effect) without dis-turbing them, comfort and working hours are increased.HVLS fans are used in various industrial areas, commercial spaces, social spaces, factories, logistics warehouses, automotive service buildings, sports halls and residential areas by working in coordination with HVAC systems where energy saving is required with developing technology.12357647654321Double Angle Adjustable BracketSafety RopesEngine Housing And Protection Covers Belt Safety Hooks Steel Ring Seat BeltsFan Hub and Bottom Cover Aerodynamic Aluminum Blades1Fan Control Board:•Standard Speed C ontroller (Inverter).• External Touch Screen (HMI).• Inboard Ventilation And Temperature Control.•Add-on Fan Control Options ..Benefits of Celling Fans:Offer silent operation. Supply winter destratification and summer cooling.Offer multi-fan control and adjustable fan speed.Help reduce condensation on floors and equipments.Work coordinated with high velocity fans and other air conditioning systems.Assist in the removal of contaminant and heat.Cut energy consumption for heating. Provide eco-friendly and economic solutions.Require lower cost for investment, installation and maintenance than traditional cooling methods.Product Details :Fans are tested and simulated for best results.Safety Cable secures the fan to the mounting structure. Fan can be mounted to different construction profiles.Custom mounting systems for customersDesigned best for users safety and comfort.Body conducts heat into the air layer Summer CoolingBefore ProfanAfter ProfanHeated air collects at ceilingHVLS Fans Supply warm air destratificationBefore ProfanAfter ProfanCooling by air movementIE SUPERPremiumE ciencyIE5IE4IE3IE2Motor Efficiency ClassFan Diameterbetween Ø 8.2ft - 24ft(2.5m - 7.3m)• Saving up to 30% in summer.• Comfortable Coolness in Outdoor• 7.3m diameter fan sizes.•3m-6m Pole Fan Length Size3INVERTERCONTROLMOTORGEARREDUCER55d BA<45d BA<PERMANENTMAGNET6BLADESFan Control Board:Inboard Ventilation And Temperature Control.*Weight of fans change depending on the lenght and design of ceiling mounting brackets.*Coverage area is affected by objects such as obstructing the airflow. (columns, walls, machines, furnitures...)5Benefits of Celling Fans:Offer silent operation. Supply winter destratification and summer cooling.Offer multi-fan control and adjustable fan speed.Help reduce condensation on floors and equipments.Work coordinated with high velocity fans and other air conditioning systems.Assist in the removal of contaminant and heat.Cut energy consumption for heating. Provide eco-friendly and economic solutions.Require lower cost for investment, installation and maintenance than traditional cooling methods.8BLADESINVERTERCONTROLMOTOR123456123Double Angle Ceiling Mount Apparatus Engine Housing And Protection Cover Steel Safety Ropes456Belt Safety HooksSteel Ring Safety ConnectionsAerodynamic Aluminum BladesTechnical Details :6Benefits of Jumbo Fans:•Offers Easy and Safe Use.• Economical with Low Energy Consumption.• Enables Coolness in Wide Area with High Diameter.• Long And Healthy Engine Life With Reducer Design.•Wide Range of Color Options. (Colors with RAL Code)Product Details :• Designed best for users safety and comfort.• Protective wire grating is available as standard.• The most suitable materials were used in the tests.• Body length can be manufactured specially for the user.•Fan angle can be adjustable at certain limits to the enviroment which used.7INVERTERCONTROLMOTOR6BLADESFan Control Board:• Standard Speed C ontroller (Inverter).• External Touch Screen (HMI).• Inboard Ventilation And Temperature Control.•Add-on Fan Control Options ..Technical data :• Two different types of motors are available.• Water and Dust Resistant in Outdoor Areas.• 3 Year Warranty Period.•Powder Coating Painted Body.8Order Code Fan Diameter Ø (mm)Motor Power (KW)Covarage Area (m²)Maximum Speed (Rpm)Weight (kg)Maksimum Speed P.Consumption(KWh)Maximum SpeedCurrent (Amps)Airflow (m³/s)*Coverage area is affected by objects such as obstructing the airflow. (columns, walls, machines, furnitures...)T echnicial SpecificationsJfan16ft (1.83m)1501,51,323818414,56• Easy to use & Cycle Controlled • 6 Blades, 6 ft (1.80m) Fan Diameter • High Performance & Durability • Easy PortabilityBenefits of Mobile Pivot Fans :• Offers Easy and Safe Use.• Economical with Low Energy Consumption.• Provides Wide Area Cooling with 160 ° Swing Function.• Long And Healthy Engine Life With Reducer Design.•Convenient than current cooling systems in point of cost and usage.9INVERTERCONTROLMOTORProduct Details :Fans are tested and simulated for best results.Safety cage standardly available.Fan can be mounted to different construction profiles.Custom mounting solutionsDesigned best for users safety and comfort.6BLADESP�vot Soc�al FanMobile Pivot Fans1234510Fan Control Board:• Standard Speed C ontroller (Inverter).• External Touch Screen (HMI).• Inboard Ventilation And Temperature Control.•Add-on Fan Control Options ..Flexible Solutions for Ventilation at Every Place Flexible Pivoting Joints Allow Head Angle Adjustments Up to 160° of Airflow, Wide Coverage Area High Performance & Heavy Duty8 Blades, Fan Sizes up to 5ft (1.52m)P�vot Soc�al Fans11Benefits of Pivot Social FansOffer multi-fan control and adjustable fan speed.With oscillating head option, up to 160 degrees of airflow covers wide area.It offers high performance, heavy duty and affordable solutions.Assist in the removal of contaminant and heat. Help reduce condensation on floors and equipments.The fan can be easily pivoted up or down to aim in one direction for optimal air flow.Require lower cost for investment, installation and maintenance than traditional cooling methods.It is recommended for places where ceiling heigh is low. It offers flexible solutions for ventilation at every place.Product Details :Fans are tested and simulated for best results.Safety cage standardly available.Fan can be mounted to different construction profiles.Custom mounting solutionsDesigned best for users safety and comfort.• Up to 160° of Airflow, Wide Coverage Area • 8 Blades, Fan sizes up to 5ft (1.52m)• High Performance & Durability• Flexible Solutions for Ventilation at Every Place• Flexible Pivoting Joints Allow Head Angle Adjustments12INVERTERCONTROLMOTORAdjustable Ceiling or Column Mounting Bracket160° Oscillating FunctionInventer Control AC MotorHorizontal Pivot Adjustable HeadAerodynamic Aluminium Blades Galvanized Fan CageFan Control Board:• Standard Speed C ontroller (Inverter).• External Touch Screen (HMI).• Inboard Ventilation And Temperature Control.•Add-on Fan Control Options ..6BLADES123456• Cow Farms..• Chicken Farms..• Up to 25 % Increase on Milk Production of Dairy Cows.• Offers Cooling and Comfort for Dairy Cows.• Up to 160° of Airflow, Wide Coverage Area.• High Performance & Durability.•Reliable & Quiet Operation.13Pivot Farm FansBenefits of Pivot Farm FansOffer multi-fan control and adjustable fan speed.(Optionally required)With oscillating head option, up to 160 degrees of airflow covers wide area.It offers eco-friendly and affordable solutions.Assist in the removal of contaminant and heat. Help reduce condensation on floors and equipments.The fan can be easily pivoted up or down to aim in one direction for optimal air flow.15 °C is ideal ambient temperature for dairy cows’ milk production. Inconvenient conditions and hot weather effects negatively.Layer of warm air on body and blow flies annoy cows. However, Pivot Farm Fans distract them with maximum air movement andoffers cooling and comfort for dairy cows. Also Pivot Farm Fans sustain to increase productivity of them.• Ideal ambient tempreture for cows is 15 degrees. Hot ambient stress is a problem which causes low milk efficiency for cows. Heat layer and flies disturbs animals. Pivot Farm Fans moves away the heat layer and flies with air flow which is cause coolness and increase efficiency.14INVERTERCONTROLMOTOR6BLADESEye Bolts for Suspended MountingSteel FrameCeiling or Column Mounting Bracket 160° Oscillating Function Horizontal Pivot Adjustable Head Aerodynamic Aluminium BladesVee Belt Drive Motor or Gear Reducer AC MotorOrder Code Fan Diameter Ø (mm)Motor Power (KW)Coverage Area (m²)Maximum Speed (Rpm)Weight (kg)Maximum Speed P. Consumption(KWh)Maximum Speed System Current(Amps)Airflow (m³/s)*Weight of fans change depending on the lenght and design of mounting brackets.*Coverage area is affected by objects such as obstructing the airflow. (columns, walls, machines, furnitures...)T echnical SpecificationÇİFTLİK66ft (1.83m)2942.22150 -350110218•Our 6 Blade HVLS fans can be used in cow and chicken farms.• In summer you can relax in a more comfortable area as it provi-des coolness and relaxation on animals.• It plays an effective role in the fertilizer and soil ventilation.Remote ControllerOf FansHome Type Fans Of Alsanfan’s15Profan IstanbulModel: 93PRF-7046-A Light: Available/Led Diameter: 235 cmTimer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-RightMotor Power: 100 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 50m2PProfan ModernModel: 52PRF-3092-ALight: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 38 W Meteryal: Wood Controller: Remote C. Coverage Area: 32m2Profan HisarModel: 52PRF-7063Light: Available/Led Diameter: 132 cmTimer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-RightMotor Power: 35 W Meteryal: Plastic Controller: Remote C. Coverage Area: 32m2PPProfan HardwoodModel: 52PRF-3092Light: -Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 38 W Meteryal: Wood Controller: Remote C. Coverage Area: 32m2PProfan Hisar WhiteModel: 52PRF-7063-W Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 HoursSupply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: Plastic Controller: Remote C. Coverage Area: 32m2PProfan Istanbul Brown MiniModel: 60PRF-7025-KALight: Available/Led Diameter: 152 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 96 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 32m2Profan Istanbul - Without LampModel: 93PRF-7046Light: -Diameter: 235 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 100 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 50m2Profan Istanbul BrownModel: 93PRF-7046-B Light: Available/Led Diameter: 235 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 100 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 50m2Profan Modern DarkModel: 52PRF-3092-DA Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 38 W Meteryal: Wood Controller: Remote C. Coverage Area: 32m2Profan Istanbul OutdoorModel: 93PRF-7046-W Light: -Diameter: 235 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 100 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 50m2PrProfan Istanbul MiniModel: 60PRF-7025-A Light: Available/Led Diameter: 152 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 100 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 35m2PHVLS FAN INDUSTRY16Profan ChichtWe C.2m2htWe C.2m2Profan BosphorusModel: 52PRF-7062-B Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: Plastic Controller: Remote C.Coverage Area: 32m2Profan StormModel: 56PRF-820 Light: Available/Led Diameter: 142cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 40W Meteryal: PlasticController: Remote C. Coverage Area: 42m2Profan GalataModel: 52PRF-002-B Light: -Diameter: 135 cm Timer: -Supply: AC100-250VRotation: Letf-Right Motor Power: 80 W Meteryal: WoodController: Manual Coverage Area: 30m2Profan RetroModel: 52PRF-002Light: -Diameter: 132 cm Timer: -Supply: AC100-250VRotation: Letf-Right Motor Power: 70 W Meteryal: WoodController: Manual Coverage Area: 32m2Profan FrostyModel: 52PRF-1008Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: Plastic Controller: Remote C. Coverage Area: 32m2htWe C.2m2Profan FunnyModel: 52PRF-1060Light: Available Diameter: 107 cm Timer: -Supply: AC100-250VRotation: Letf-Right Motor Power: 100 W Meteryal: Wood Controller: ManualCoverage Area: 30m2Profan SunnyModel: 52PRF-1060-A Light: Available Diameter: 107 cm Timer: -Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: Wood Controller: Manual Coverage Area: 30m2htWe C.2m2Profan Bosphorus SteelModel: 52PRF-7062-MS Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: PlasticController: Remote C. Coverage Area: 32m2Profan DaisyModel: 65PRF-801-DC Light: Available/Led Diameter: 165 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 38 W Meteryal: Wood Controller: Remote C. Coverage Area: 42m2Model: 52PRF-811Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 32 W Meteryal: Plastic Controller: Remote C. Coverage Area: 32m2htWe C.2m2Profan ActiveModel: 52PRF-868Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: PlasticController: Remote C. Coverage Area: 32m2Profan DarkModel: 56PRF-821-B Light: -Diameter: 140 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 22 W Meteryal: PlasticController: Remote C. Coverage Area: 35m2Profan WhiteModel: 56PRF-821-W Light: -Diameter: 140 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 22 W Meteryal: Plastic Controller: Remote C. Coverage Area: 35m2Profan Bosphorus WhiteModel: 52PRF-7062-W Light: Available/Led Diameter: 132 cm Timer: 1/2/4/8 Hours Supply: AC100-250VRotation: Letf-Right Motor Power: 35 W Meteryal: Aluminyum Controller: Remote C. Coverage Area: 32m2Ikitelli Atatürk Mah. Marmara San. Sit. S Blok No:8 Küçükçekmece - Istanbul / TURKEY Tel: (0212) 494 25 25 Fax: (0212) 494 45 97*****************//alsanfanHVLS FAN INDUSTRY。
V5011P双向线头球式阀门产品数据应用说明书
V5011P TWO-WAY THREADED GLOBE VALVEPRODUCT DATAAPPLICATIONThe V5011P is a two-way threaded globe valve that controlsteam, water, and glycol solutions (up to 50 percentconcentration) in heating or cooling HVAC applications. Thevalve is used in two-position and modulating control systems.The valve is not suitable for combustible gas service.FEATURES•Red brass body with BSPT-threaded end connections.•Low seat leakage rate (≤0.05 percent of C v).•50:1 rangeability per VDI/VDE 2173.•Spring-loaded, self-adjusting packing.•Accurate positioning to ensure state of the arttemperature control.•Directly coupled electric and pneumatic actuatorsfor easy mounting.•Sizes rang from 1-1/4 in. to 2 in.•Valve designs provide equal percentage flowcharacteristic for water and linear flow characteristic forsteam.•Stainless steel stem and metal-to metal seats.•Repack and rebuild kits for field servicing.APEN0H-003TW01A0604V5011P TWO-WAY THREADED GLOBE VALVEAPEN0H-003TW01A06042SPECIFICATIONSIMPORTANTThe specifications given in this publication do not include normal manufacturing tolerances. Therefore,an individual unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed.Models:V5011P Valve: Two-way threaded globe valve for steam,water, or glycol. BSPT-threaded pipe connections. Throttling plug provides equal percentage flow characteristic for water (V5011P1xxx), linear flow characteristic for steam (V5011P2xxx).NOTE: V5011P1xxx and V5011P2xxx are direct acting (stem down to close).Dimensions: See Fig. 1.Valve Sizes and Flow Capacities: See Table 1.Pipe Connections: Internal BSPT-threaded connections.Seat: Stainless steel, replaceable ANSI Body Class: 300 psi.Stem: Stainless steel.Plug: Brass on V5011P1xxx,stainless steel on V5011P2xxx for steam.Stroke: 3/4 in. (20 mm).Approximate Leakage Rate: 0.05 percent C v .Pattern: 2-way, straight-through.Body Material: Red brass.Packing: Spring-loaded, carbon fiber reinforced PTFE V-rings.Rangeability: 50:1 per VDI/VDE 2173.Pressure-Temperature Ratings:Water: 36°F to 248°F, 217 psi (15 bar).248°F to 337°F, 185 psi (12.8 bar).Maximum Water Differential Pressure: 230 psid (15.8 bar).Steam: 100 psi (6.9 bar) at 337°F (V5011P2xxx).Maximum Differential for Quiet Water Service: 20 psid.Valve Flow Characteristics:Water: Equal percentage (V5011P1xxx).Steam: Linear (V5011P2xxx). See Fig. 2.Close-Off Pressure Ratings: See Fig. 3, and Table 2.Valve Design Life: 250,000 full cycles at maximum rated temperature.Replacement Parts: See Fig. 5 and Table 3.Motor and Linkage Selection:Table 1. Valve Size and Flow Capacities.V5011P TWO-WAY THREADED GLOBE VALVE3APEN0H-003TW01A0604V5011P TWO-WAY THREADED GLOBE VALVEAPEN0H-003TW01A06044V5011P TWO-WAY THREADED GLOBE VALVE5APEN0H-003TW01A0604INSTALLATIONWhen Installing This Product.1. Read these instructions carefully. Failure to follow themcould damage the product or cause a hazardous condition.2. Check the ratings given in the instructions and on theproduct to make sure the product is suitable for your application.3. Installer must be a trained, experienced servicetechnician.4. After installation is complete, check out productoperation as provided in these instructions.IMPORTANT1. Do not lift the valve by holding the stem.2. Do not mount the valve with the stem pointed lowerthan horizontal.3. Mount the valve with the flow arrow pointed in thedirection of flow through the valve.4. Mount the valve between aligned pipes. Mountingthe valve on pipes that are not aligned causes leakage at the valve-to-pipe connection.5. Ensure complete engagement on pipe to valve bodythreads.6. Hold the valve body with a clamp or pipe wrench on thehexagonal fitting nearest the pipe to prevent damage to the valve body while mounting on the pipe. Refer to Fig.4.7. 7. Be sure to allow enough room for installation andservice. Clearance for valve installation is dependent on actuator size and the valve pipe size.LocationSelect a location where the valve, linkage, and actuator are within the appropriate pressure and temperature ratings.Leave sufficient clearance above the valve to accommodate actuator installation and allow room for servicing the valve body. (Completely install the valve body in the pipe line before installing the actuator and linkage.)When selecting a location for the valve, consider actuator mounting restrictions. Modutrol IV TM Motor crankshafts mustbe mounted horizontally.V5011P TWO-WAY THREADED GLOBE VALVEAPEN0H-003TW01A06046MountingThe preferred valve mounting position is with the stemvertical. For steam applications, mount with the stem at a 45degree angle. Do not mount the valve with the stem more than 90 degrees from the vertical (pointing lower thanhorizontal). Scale and foreign material can collect, scoring the stem and causing packing leakage. Protect the stem from damage due to bending or scratching.IMPORTANT1. Before installing linkage and actuator, make sure that the valve stem operates freely. Impaired stem operation can indicate that the body was twisted or the stem was bent. Either of these conditions can require valve replacement.2. Align pipes squarely with valve at each end connections.3. If the pipes are forced into the valve, the body can become twisted and improper seating can result.4. Apply pipe dope sparingly.5. Be careful to prevent pipe debris, such as chips and scale, from entering the piping because this material can lodge in the seat and prevent proper closing.NOTE: Threading on threaded bodies conform to BSPT.Refer to the table in Fig. 4 for valve pipe sizes and thread lengths. Fig. 4 also shows two effective methods of holding the valve and pipe when attaching it. Refer to installation information furnished with the linkage and motor wheninstalling these controls.V5011P TWO-WAY THREADED GLOBE VALVEAPEN0H-003TW01A06047CHECKOUTUse the following procedure to check for proper valve operation:1. Check valve body and connections for leaks.2. After installing linkage and actuator, check operationaccording to installation information furnished with these controls.3. Operate system through one complete cycle to ensurevalve controls properly.4. Check valve at regular intervals for leakage aroundpacking.NOTE: Packing is spring-loaded and should seldom requireattention.5. If leakage is discovered and inspection shows that thepacking gland is screwed down tightly, then repack the valves.IMPORTANTBefore installing linkage (if used) and actuator, make sure that the valve stem operates freely. Impaired stem operation can indicate that the body was twisted or the stem was bent. Either of these conditions can require valve replacement.Table 3. Valve Rebuild and Repack Kits.Order Number BSPT size Flow Capacity C vStem Diameter (in.)Repack Kit Rebuild Kit V5011P1004DN2511.70901752A V5011P1012DN3218.70901753AV5011P1020DN4029.30901787A0901754A V5011P1038DN5046.83/80901755A V5011P2002DN3218.70903429A V5011P2010DN4029.30901787A0903430A V5011P2028DN5046.80903431AV5011P TWO-WAY THREADED GLOBE VALVEAutomation and Control SolutionsHoneywell Taiwan Ltd.10F, 168 Lien Cheng RoadChung Ho City, Taipei County, TaiwanPhone: +886-2-2245 1000Fax: +886-2-2245 3241Subject to change without notice. Printed in TaiwanAPEN0H-003TW01A06048。
瑞丰WI-E-045A1型号电子产品规格书说明书
information on the applications如产品需要用在有特殊质量要求及可靠性要求的地LEDs without having consentinform Refond in writinganalysis.在取得瑞丰的同意前,客户不应该对产品进行拆解分析,如发现失效产品,请直RF-W3S198TS-A12Features 特征Extremely wide viewing angle.发光角度大Suitable for all SMT assembly and solder process.适用于所有的SMT组装和焊接工艺 Moisture sensitivity level:Level3.防潮等级Level3Package:4000pcs/reel.包装每卷4000pcsRoHS compliant.满足RoHS要求Description描述The Colour LED which was fabricated using blue,green and orange chip 该产品为三色光LED,是由蓝光、绿光和橙光晶片封装形成Applications应用Optical indicator.光学指示Switch and Symbol,Display.开关和标识、显示器等General use.其他应用Package Dimension 外观尺寸NOTES:1.All dimensions units are millimeters.(所有尺寸标注单位为毫米)2.All dimensions tolerances are±0.2mm unless otherwise noted.(除特别标注外,所有尺寸公差为±0.2毫米)----Note:备注Vr=5V For test conditions.Vr=5v为测试分选条件。
Absolute Maximum Ratings at Ts=25°C 绝对最大值1.2.3.4.5.6.Typical optical characteristics curves典型光学特性曲线Packaging Specifications⏹Carrier Tape Dimensions载带尺寸Note:Thetolerances unless mentioned ±0.1mm.Unit :mm 注:未注公差为±0.1毫米,尺寸单位:毫米。
施耐德HVX系列中压真空断路器.
HVX 系列中压真空断路器中压户内开关设备产品目录施耐德电气善用其效 尽享其能施耐德电气在中国1987年,施耐德电气在天津成立第一家合资工厂梅兰日兰,将断路器技术带到中国,取代传统保险丝,使得中国用户用电安全性大为增强,并为断路器标准的建立作出了卓越的贡献。
90年代初,施耐德电气旗下品牌奇胜率先将开关面板带入中国,结束了中国使用灯绳开关的时代。
施耐德电气的高额投资有力地支持了中国的经济建设,并为中国客户提供了先进的产品支持和完善的技术服务,中低压电器、变频器、接触器等工业产品大量运用在中国国内的经济建设中,促进了中国工业化的进程。
目前,施耐德电气在中国共建立了77个办事处,26家工厂,6个物流中心,1个研修学院,3个研发中心,1个实验室,700多家分销商和遍布全国的销售网络。
施耐德电气中国目前员工数近22,000人。
通过与合作伙伴以及大量经销商的合作,施耐德电气为中国创造了成千上万个就业机会。
施耐德电气 能效管理平台全球能效管理专家施耐德电气为世界100多个国家提供整体解决方案,其中在能源与基础设施、工业过程控制、楼宇自动化和数据中心与网络等市场处于世界领先地位,在住宅应用领域也拥有强大的市场能力。
致力于为客户提供安全、可靠、高效的能源,施耐德电气2010年的销售额为196亿欧元, 拥有超过110,000名员工。
施耐德电气助您——善用其效,尽享其能!凭借其对五大市场的的深刻了解、对集团客户的悉心关爱,以及在能效管理领域的丰富经验,施耐德电气从一个优秀的产品和设备供应商逐步成长为整体解决方案提供商。
今年,施耐德电气首次集成其在建筑楼宇、IT 、安防、电力及工业过程和设备等五大领域的专业技术和经验,将其高质量的产品和解决方案融合在一个统一的架构下,通过标准的界面为各行业客户提供一个开放、透明、节能、高效的能效管理平台,为企业客户节省高达30%的投资成本和运营成本。
HVX 中压真空断路器系列目录HVX 真空断路器 (2)基本特征 (2)标准 (2)环境和运行条件 (2)设计 (3)机构 (3)极柱 (4)型号组成及面板操作 (5)手车式结构示意图 (5)试验及电寿命 (6)试验 (6)真空灭弧室允许操作次数与开断电流的关系 (6)应用 (6)二次装置 (7)二次装置电压等级 (9)选型表 (10)HVX 12kV 真空断路器 (10)HVX 24kV 真空断路器 (12)HVX 40.5kV 真空断路器 (14)二次电路图 (16)HVX 12kV/24kV 真空断路器手车式带防跳继电器 (16)HVX 12kV/24kV 真空断路器手车式无防跳继电器 (17)HVX 12kV/24kV 真空断路器固定式带防跳继电器 (18)HVX 12kV/24kV 真空断路器固定式无防跳继电器 (19)HVX 12kV/24kV 真空断路器电动手车式带防跳继电器 (20)HVX 12kV/24kV 真空断路器电动手车式无防跳继电器 (21)HVX 40.5kV 真空断路器手车式带防跳继电器 (22)HVX 40.5kV 真空断路器手车式无防跳继电器 (23)HVX 40.5kV 真空断路器固定式带防跳继电器 (24)HVX 40.5kV 真空断路器固定式无防跳继电器 (25)外型尺寸图 (26)HVX 12kV 真空断路器固定式 (26)HVX 12kV 真空断路器手车式 (27)HVX 12kV 真空断路器固定式 (28)HVX 12kV 真空断路器手车式 (29)HVX 24kV 真空断路器手车式 (30)HVX 40.5kV 真空断路器固定式 (32)HVX 40.5kV 真空断路器中置手车式 (33)HVX 40.5kV 真空断路器落地手车式 (1200mm柜宽) (34)HVX 40.5kV 真空断路器落地手车式 (1400mm柜宽) (35)订货表 (36)HVX 12kV/24kV 真空断路器订货表 (36)HVX 40.5kV 真空断路器订货表 (37)HVX 中压真空断路器系列HVX 系列真空断路器是施耐德电气在中压领域百年的技术结晶,适用于主流的空气绝缘开关设备,广泛地应用于石油化工、配电系统、交通运输、工矿企业等领域。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
High Efficiency Red
105 30 150 5
Super Bright Green
105 25 150 5
Yellow
105 30 150 5
Super Bright Red
100 30 150 5
Units
mW mA mA V
-40 °C To +85 °C 260 °C For 5 Seconds
7-S50-1
Selection Guide
Part No.
SA50-11EWA SC50-11EWA SA50-11YWA SC50-11YWA SA50-11SRWA SC50-11SRWA SA50-11Sv (ucd) @ 10 mA Min. Max.
SIZE. l5.0 INCH DIGIT HEIGHT. lEXCELLENT CHARACTER APPEARANCE. lHIGH LIGHT OUTPUT. lEASY MOUNTING ON P.C. BOARDS OR SOCKETS. lI.C. COMPATIBLE. lCATEGORIZED FOR LUMINOUS INTENSITY, YELLOW AND GREEN CATEGORIZED FOR COLOR. lMECHANICALLY RUGGED. lSTANDARD : GRAY FACE, WHITE SEGMENT. Package Dimensions
High Efficiecny Red
7-S50-3
Super Bright Green
Yellow
7-S50-4
Super Bright Red
7-S50-5
Typ.
625 565 590 660 45 30 35 20 12 45 10 95 2.0 2.2 2.1 1.85 10
Max.
Units
Test Conditions
λpeak
Peak Wavelength
nm
IF=20mA
∆λ1/2
Spectral Line Halfwidth
Super
nm
Symbol Parameter Device
High Efficiency Red Super Bright Green Yellow Super Bright Red High Efficiency Red Super Bright Green Yellow Bright Red High Efficiency Red Super Bright Green Yellow Bright Red High Efficiency Red Super Bright Green Yellow Bright Red All
Parameter
Power dissipation DC Forward Current Peak Forward Current [1] Reverse Voltage Operating/Storage Temperature Lead Soldering Temperature [2]
Notes: 1. 1/10 Duty Cycle, 0.1ms Pulse Width. 2. 4mm below package base
21000
Description
Common Anode, Rt. Hand Decimal Common Cathode, Rt. Hand Decimal Common Anode, Rt. Hand Decimal Common Cathode, Rt. Hand Decimal Common Anode, Rt. Hand Decimal Common Cathode, Rt. Hand Decimal Common Anode, Rt. Hand Decimal Common Cathode, Rt. Hand Decimal
Internal
Circuit
Diagram
Notes:
1. All dimensions are in millimeters (inches), Tolerance is ±0.25(0.01")unless otherwise noted. 2. Specifications are subjected to change whitout notice.
HIGH EFFICIENCY RED (GaAsP/GaP)
14000
YELLOW (GaAsP/GaP)
9000
14000
SUPER BRIGHT RED (GaAlAs)
31000
50000
SUPER BRIGHT GREEN (GaP)
21000
31000
Electrical / Optical Characteristics at TA=25°C
IF=20mA
C
Capacitance
Super
pF
VF=0V;f=1MHz
vF IR
Forward Voltage
Super
2.5 2.5 2.5 2.5
V
IF=20mA
Reverse Current
uA
VR = 5V
7-S50-2
Absolute Maximum Ratings at TA=25°C
Kingbright
Features
lLARGE
®
127mm (5.0INCH) SINGLE DIGIT NUMERIC DISPLAYS
SA50-11 SC50-11
Description
The Super Bright Green source color devices are made with Gallium Phosphide Green Light Emitting Diode. The High Efficiency Red source color devices are made with Gallium Arsenide Phosphide on Gallium Phosphide Orange Light Emitting Diode. The Yellow source color devices are made with Gallium Arsenide Phosphide on Gallium Phosphide Yellow Light Emitting Diode. The Super Bright Red source color devices are made with Gallium Aluminum Arsenide Red Light Emitting Diode.