IXGH20N100;中文规格书,Datasheet资料

合集下载

IXGH17N100A;IXGH17N100;中文规格书,Datasheet资料

IXGH17N100A;IXGH17N100;中文规格书,Datasheet资料

© 1996 IXYS All rights reservedSymbol Test Conditions Maximum RatingsV CES T J = 25°C to 150°C1000V V CGR T J = 25°C to 150°C; R GE = 1 M Ω1000V V GES Continuous ±20V V GEM Transient ±30V I C25T C = 25°C 34A I C90T C = 90°C 17A I CMT C = 25°C, 1 ms68A SSOA V GE = 15 V, T VJ = 125°C, R G = 82 Ω I CM = 34A (RBSOA)Clamped inductive load, L = 300 µH @ 0.8 V CESP C T C = 25°C150W T J -55 ... +150°C T JM 150°C T stg -55 ... +150°CM d Mounting torque (M3) 1.13/10Nm/lb.in.WeightTO-204 = 18 g, TO-247 = 6 gMaximum lead temperature for soldering 300°C1.6 mm (0.062 in.) from case for 10 sSymbol Test ConditionsCharacteristic Values(T J = 25°C, unless otherwise specified)min.typ.max.BV CES I C = 3 mA, V GE = 0 V 1000V V GE(th)I C= 250 µA, V CE = V GE2.55V I CES V CE = 0.8 • V CES T J = 25°C 250µA V GE = 0 VTJ = 125°C1mA I GES V CE = 0 V, V GE = ±20 V ±100nA V CE(sat)I C= I C90, V GE = 15 V17N100 3.5V 17N100A4.0VTO-247 AD (IXGH)V CESI C25V CE(sat)Low V CE(sat) IGBT IXGH/IXGM 17 N1001000 V 34 A 3.5 V High speed IGBTIXGH/IXGM 17 N100A 1000 V 34 A4.0 VGCETO-204 AE (IXGM)CG = Gate, C = Collector,E = Emitter,TAB = CollectorFeaturesl International standard packages l 2nd generation HDMOS TM process l Low V CE(sat)-for low on-state conduction losses l High current handling capability l MOS Gate turn-on -drive simplicitylVoltage rating guaranteed at high temperature (125°C)Applicationsl AC motor speed control l DC servo and robot drives l DC choppersl Uninterruptible power supplies (UPS)lSwitch-mode and resonant-mode power suppliesAdvantageslEasy to mount with 1 screw (TO-247)(isolated mounting screw hole)lHigh power density91515E (3/96)IXYS MOSFETS and IGBTs are covered by one or more of the following U.S. patents:4,835,5924,881,1065,017,5085,049,9615,187,1175,486,7154,850,0724,931,8445,034,7965,063,3075,237,4815,381,025IXYS reserves the right to change limits, test conditions, and dimensions.SymbolTest ConditionsCharacteristic Values(TJ = 25°C, unless otherwise specified)min.typ.max.g fs I C = I C90; V CE = 10 V,615S Pulse test, t ≤ 300 µs, duty cycle ≤ 2 %C ies 1500pF C oes V CE = 25 V, V GE = 0 V, f = 1 MHz175pF C res 40pF Q g 100120nC Q ge I C = I C90, V GE = 15 V, V CE = 0.5 V CES 2030nC Q gc 6090nC t d(on)100ns t ri 200ns t d(off)5001000ns t fi 17N100750ns 17N100A 450750ns E off 17N100A3mJ t d(on)100ns t ri 200ns E on 2.5mJ t d(off)7001000ns t fi 17N10012002000ns 17N100A 7501000ns E off 17N1008mJ 17N100A 6mJR thJC 0.83K/WR thCK0.25K/WIXGH 17N100 and IXGH 17N100 A characteristic curves are located on the IXGH 17N100U1 and IXGH 17N100AU1 data sheets.Inductive load, T J = 25°C I C = I C90, V GE = 15 V, L = 300 µH,V CE = 0.8 V CES , R G = R off = 82 ΩRemarks: Switching times may increasefor V CE (Clamp) > 0.8 • V CES ,higher T J or increased R G Inductive load, T J = 125°C I C = I C90, V GE = 15 V, L = 300 µH V CE = 0.8 V CES , R G = R off = 82 ΩRemarks: Switching times may increasefor V CE (Clamp) > 0.8 • V CES ,higher T J or increased R G分销商库存信息:IXYSIXGH17N100A IXGH17N100。

Sygonix 蒸汽器恒温器 HT100 用户手册说明书

Sygonix 蒸汽器恒温器 HT100 用户手册说明书

User manualSYGONIXradiator thermostat HT100Art.-No. 1377979ControlsHeating TimeBatterieverbrauchVacation FunctionEconomy TemperatureOpen WindowFunctionkeylockAttentionPROG TEMP ZEITFENS RESADAP URLA INST OFFS VERSMODE time (minutes)1. Remove battery cover/Insert batteries2. Enter Date and Time3.a Mounting on the radiator without adapterValve - Radiator Thermostat HT1001.OKOKOKMountingNo adapter is required for the following valves:Heimeier, Junkers Landys+Gyr, MNG, Honeywell Braukmann, since these have threaddimensions of M30 x 1.5 mm. Adapters for Danfoss RAV (pin must be put on the valve tappet) Danfoss RA and Danfoss RAVL are enclosed.An adapter is required for the following valves:Herz M28 x 1,5 mm, Comap M28 x 1,5 mm, Vaillant 30,5 mm, Oventrop M30 x 1,0 mm, Meges M38 x 1,5 mm, Ondal M38 x 1,5 mm, Giacomini 22,6 mm, Rossweiner M33 x 2,0 mm, Markaryd M28 x 1,0 mm, Ista M32 x 1,0 mm, Vama M28 x 1,0 mm, Pettinaroli If E1appears in the display then the installation was not successful. Look at the Support Table.4. Adapt3.b Mounting on the radiator with adapter Valve – Adapter – Radiator Thermostat HT100Start ready.1.OKPull the battery cover, in the recess on the underside of the housing, upwards. Insert two batteries of type AA/Mignon with correct polarity (observe plus / + and minus / -, see imprint in the battery compartment). Pay attention to the correct position of the batteries to avoid contact interference. Close the battery compartment again. Due to the lower output voltage of batteries (batteries = 1.5V, rechargeable batteries = 1.2V) there may be a very short period of operation. We therefore recommend to use high quality alkaline batteries for a long and safe operation.• For safety and licensing (CE) reasons, unauthorized conversion and/or modification of the product is prohibited. NEVER disassemble it.• The product is not a toy, it does not belong in children‘s hands.• The product is only suitable for indoor use, it must not get damp or wet.• Do not carelessly leave packaging material lying around.• It could be a dangerous toy for children.• Be careful when using the product. Knocks, blows or even a fall from a low height can damage it.• Should you have any questions that are not answered in this manual, please contact us or another professional.• Keep batteries out of the reach of children. Do not let batteries lying around openly as there is the danger of them being swallowed by child-ren or pets. If swallowed, consult a doctor immediately!• Leaking or damaged batteries can cause burns on contact with skin, therefore use suitable protective gloves when handling them. Leaking battery fluids are chemically very aggressive. Objects or surfaces which come into contact with them, can sometimes be massively damaged. Keep batteries at a suitable location.• Batteries must not be shorted, disassemble or thrown into the fire. Risk of explosion!• Conventional non-rechargeable batteries cannot be recharged, Risk of explosion!• Do not mix batteries with different state (e.g., full and half-full batteries. Always replace the whole set of batteries.• When inserting the batteries pay attention to the correct polarity (Note: Plus / + and minus).OKdd:mmy y y yhh:mmRAV PinBold for AdapterBasic Operating ModesMANU mode: In the MANU Mode HT100 regulates to the set temperature by hand.AUTO Mode: HT100 changes in the AUTO Mode according to the set Time program between two temperatures.The heating and economy times can be specified via the adjustable time program.A maximum of 8 switch points (4 heating and 4 economy times) may be set per day.The Radiator Thermostat HT100 has the following factory settings:Heating time: Heating to comfort temperature(factory setting: 1. heating time at 07:00 clock - 21 ° C) Saving time: Reduction to economy temperature (factory setting: 1. saving time at 22:00 clock - 16 ° C)With the setting wheel a change in the room temperature is possible in the AUTO Mode at any time, this will remain until the next switching point. The process can be terminated prematurely by pressing the MENU button.Button: Main MenuButton: ConfirmationMENUOKButton: Timer functionMANU/AUTOModusHere any temperature for a selected time period can be set. Press button, set the time for which the timer program is to be overridden. Confirm with OK. Set the desired temperature. Confirm with OK. A manual temperature change is then in the given period not possible, the setting wheel is locked. By pressing the Menu button, the lock-up can be released.Setting HolidaysFirst set the date of the re-start of the regular heating time. (Set the end of the holiday)OKSetting OffsetkeylockTimer functionOK OK Room temperature adjustment. Here you have the possibility to set a temperature of (-5 / + 5 °). The temperature determined by the instrument may differ from the perceived temperature by the user.In this case, the temperature determined by the instrument must be adjusted.OKDeclaration of ConformityHereby, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschaudeclares, that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The Declaration ofConformity for this product can be found at GuaranteeFor damages caused by failure to observe this Instruction Manual, the warranty/guarantee is voided! For consequential damages we assume no liability! For material or personal dam-age caused by improper handling or failure to observe the safety information, we assume no liability! In such cases, the warranty/guarantee is voided!sygonix®distributed byConrad Electronic SE Klaus-Conrad-Str. 1D-92240 HirschauTechnical SpecificationsPower supply: 2 AA batteries / MignonFactory settings: Comfort temperature: 21 ° C Economy temperature: 16 ° C1. Heating time: Start 7:00 o’clock 1. Economy Time: Start 22:00 o’clock Switching points: 4 heating times, 4 economy timesFrost protection function: Yes, activation at temperature below +6 ° C Calcification protection: Yes, valve movement 1x per week Window function: YesModes: Automatic / ManualDimensions: 80 x 70 x 52 mm (W x H x D)HilfeMENU MENU ProblemCauseSolutionBatteries are lowChange batteriesnot getting warm.Valve does not open, after Summer heating pause- calcified?boilerTake off Radiator Thermostat HT100 Move by hand the valve tappets back and forth several times.Radiator is not cooling down.Valve does not close completely.Possibly the closing point of your your valve seat has moved.EAdapt again (see “Adaptation”)Repeatedly move valve tappets by hand - perhaps an adaptation is not possible because your valve may be calcified, or the seal does no longer fulfill its function.Thrust piece falls out.(This may also cause an E1 error!)Due to an endless threadthe thrust piece mounted on the bottom may fall out when the controller was not applied on the valve.Insert thrust piece. Adapt the device via the point, or by removing and re-inserting thebatteries. Now, the endless threat rotates and tightens the thrust piece firmly. Attach to the radiator and adapt again.E1-E3By pressing any button the fault indicatordisappears from the display and the adaptation restarts! E1No adaptation possible.Radiator Thermostat HT100 not mounted on radiators.s the device correctly mounted on the radiator?Mount Radiator Thermostat HT100. E2Valve lift too short or Battery power too weak.Open and close valve tappets by hand several times or install new batteries.E3No valve movement possible.Do valve tappets move freely?+Hold both buttons for several seconds. Activate key lock.T o deactivate, hold the two buttons pressed for several seconds.OKLEDThe LED lights up in each case during the heating-phase until the set temperature is reached.PROGMondaySet the beginning of the 1. Heating TimeSetting Individual ProgramSet the beginningof the 1. Economy TimeYou can optionally enter additional heating and economy periods. If you do not want to make any further settings, confirm the display …–– ––“with OK.OKOKOKOK MENUDAY1Day/Block Maintenance and CleaningMaintenance or repair may only be performed by a specialist or specialist workshop. There are no serviceable components for you inside the product, therefore, never open/disassemble it (except for the battery change as described in this manual). Never use aggressive cleaning agents, rubbing alcohol or other chemical solutions as they may cause damage to the housing or even impair its operational functions.From the date of implementation of European guidelines 2002/96/EC and 2006/66/EC, into national law, the following applies: Electric and electronicdevices and batteries may not be disposed of in household waste. The consumer is obliged to return electric and electronic devices and batteries to the public collection points established for them or to the point of sale. The particularsinstructions or packaging points to these provisions. You make an important contribution to the protection of the environment by reusing or recycling old equipment/batteries or making use of them in other ways.D1-5 Mo-Fr D1-6 Mo-Sa D1-7 Mo-SuThe process can be terminated prematurely by pressing the MENU button.。

XNX系列氢氧化物传感器的产品介绍说明书

XNX系列氢氧化物传感器的产品介绍说明书

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted6970Confidential71Confidential72Confidential73ConfidentialPart NumberDescriptionPGXNX-AMAE-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors895.00£ UB XNX-AMAE-FHNNNXNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors958.00£ UBXNX Stainless Steel Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors Part Number Description GBP PGXNX-UTSE-NNNNN XNX Transmitter, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, configured forXNX toxic and oxygen sensors975.00£ UB XNX-UTSE-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPTentries, painted 316SS, configured for XNX toxic and oxygen sensors1,037.00£ UB XNX-UTSE-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries,painted 316SS, configured for XNX toxic and oxygen sensors1,037.00£ UB XNX-UTSE-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port,UL/CSA, 3 x 3/4"NPT entries, painted 316SS, configured for XNX toxic and oxygen sensors 1,098.00£ UB XNX-UTSE-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, configured for XNX toxic and oxygen sensors1,068.00£ UB XNX-UTSE-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, configured for XNX toxic and oxygen sensors1,128.00£ UB XNX-UTSE-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, configured for XNX toxic and oxygen sensors1,098.00£ UB XNX-UTSE-FHNNNXNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, configured for XNX toxic and oxygen sensors1,159.00£ UBXNX Aluminium Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors Part Number Description GBP PGXNX-UTAE-NNNNN XNX Transmitter, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium,configured for XNX toxic and oxygen sensors767.00£ UB XNX-UTAE-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPTentries, painted Aluminium, configured for XNX toxic and oxygen sensors831.00£ UB XNX-UTAE-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries,painted Aluminium, configured for XNX toxic and oxygen sensors831.00£ UB XNX-UTAE-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port,UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors 895.00£ UB XNX-UTAE-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors863.00£ UB XNX-UTAE-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors927.00£ UB XNX-UTAE-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors895.00£ UB XNX-UTAE-FHNNNXNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors958.00£ UB74Confidential75Confidential76Confidential77ConfidentialXNX Aluminuim Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors78ConfidentialXNX Aluminuim Transmitter UL/CSA for use with Optima Plus and Searchline Excel DetectorsExcel kits including standard XNX transmitter configured with HART® over 4-20mA output and local IS HART® port. For Excel kits includingother XNX transmitter configurations contact Honeywell Analytics. A calibration has to be ordered with every XNX Excel kit.Excel gas calibration curve to be selected from section 29.2 and to be ordered additionally.23.1 InstrumentExcel kits including standard XNX transmitter with HART® over 4-20mA outputs and local IS HART® port.Excel Short Range 5m – 40m (15ft - 130ft)Part Number Description GBP PG 02104-N-XSAA XNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, aluminimum XNX, Ex e junction box with M20/M25 cable entries, 316SS mounting plates, brackets and hardware 6,518.00£ UA02104-N-XSSAXNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, stainless steel XNX, Ex e junction box with M20/M25 cable entries, 316SS mounting plates, brackets and hardware6,649.00£ UA 02104-N-XSAUXNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, UL, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, aluminimum XNX, junction box with 3/4"NPT cable entries, 316SS mounting plates, brackets and hardware6,827.00£ UA 02104-N-XSSUXNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, UL, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, stainless steel XNX, junction box with 3/4"NPT cable entries, 316SS mounting plates, brackets and hardware6,960.00£ UA 02104-N-XSACXNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, FM/CSA, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, aluminimum XNX, junction box with 3/4"NPT cable entries, 316SS mounting plates, brackets and hardware6,539.00£ UA 02104-N-XSSCXNX Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA and HART® outputs, FM/CSA, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, stainless steel XNX, junction box with 3/4"NPT cable entries, 316SS mounting plates, brackets and hardware6,671.00£ UA 02104-N-NSNAExcel line-of-sight gas detection system (without XNX, please order required XNX separately), short range (5 to 40m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperately.5,591.00£ UA83Confidential。

LG iGX样本(中文版)

LG iGX样本(中文版)
如有改动,恕不事先通知 IGX 系列变频器 2007.10 上海
-Solution Leader in Electrics& Automation
STARVERT G X
紧凑高性能变频器
0.4~22kW 3Phase 380~480Volts
Automatiom Equipment
New Name of
小心选择电流断路器. 当变频器上电的时候,可能有大 的浪涌电流涌入
为了使变频器长时间运行在高性能状态下,请把变频器安 装在正确的方向的适当的位置,留出适当的空间.不正确的 端子接线会导致设备的损坏.
有必要的情况下再安装。 如果安装了,不要用它来 启动和停止变频器。否则, 容易缩短产品的使用寿命。
控制连线
安全警告
为了您的安全,请在操作前先阅读说明书 请联系授权的服务人员进行检查、维修、调整 请由专业人员进行拆除维修
LS产电的30年
LS产电在不断地变革和成长中积累了丰富的经验。 同时具备了面临激烈竞争及挑战时也能生存并发展的强大组织力量。
取得飞跃和成长的企业 1974年 金星机电(株)创立 1987年 金星产电(株)设立 1994年 企业上市
电气及自动化领域的领先者 1995年 商号变更为LG产电(株) 1996年 取得了韩国最早变频器领域
的ISO9001认证 1998年 低压电器生产突破1亿台
第二次质的飞跃 1999年 合并LG金属(株) 1999年 转让铜管和自动销售机事业 2003年 内部调整,归属于LG电缆 2005年 更名为LS产电
动能缓冲
电源突降或瞬时掉电的情况下,变频器会出现欠压故障并保护停机。使 用此功能后,变频器在电源出现问题时会根据减速方式或直流电压参考方式 控制输出频率,利用电机产生的回馈能量维持直流侧电压以延长出现欠压保 护的时间,实现电源突降或瞬时掉电的情况下变频器能持续工作。

FAN100MY;中文规格书,Datasheet资料

FAN100MY;中文规格书,Datasheet资料

Description
The primary-side PWM controller FAN100 significantly simplifies power supply design that requires CV and CC regulation capabilities. The FAN100 controls the output voltage and current precisely with the information in the primary side of the power supply, not only removing the output current sensing loss, but eliminating secondary feedback circuitry.
Ground.
Supply. The power supply pin. IC operating current and MOSFET driving current are supplied using this pin. This pin is connected to an external VDD capacitor of typically 10µF. The threshold voltages for startup and turn-off are 16V and 5V, respectively. The operating current is lower than 5mA.
Ground.
Constant Current Loop Compensation. this pin connects a capacitor and a resistor between COMI and GND for compensation current loop gain.

74435561100;中文规格书,Datasheet资料

74435561100;中文规格书,Datasheet资料

74435561100
DATUM / DATE : 2009-11-02 Gurtspezifikation / Tape specification:
G H
SPEICHERDROSSEL WE-HCI POWER-CHOKE WE-HCI
I Rollenspezifikation / tape and reel specification:
74435561100
DATUM / DATE : 2009-11-02
SPEICHERDROSSEL WE-HCI POWER-CHOKE WE-HCI
H Induktivitätskurve / Inductance curve:
Induktivität vs Strom (typ.) Inductance vs Current (typ.)
08-09-29
Geprüft / checked
Kontrolliert / approved
Datum / date
D-74638 Waldenburg · Max-Eyth-Strasse 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400 http://www.we-online.de
12,00
10,00
8,00
L (µH)
6,00
4,00
2,00
0,00 0 5 10 15 Current (A) 20 25 30 35
Freigabe erteilt / general release:
..................................................................................

744710215;中文规格书,Datasheet资料

744710215;中文规格书,Datasheet资料

5.1 5.0 4.02012-06-272012-05-022009-06-30SStSStRStSStCZWürth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyTel. +49 (0) 79 42 945 - 0A Dimensions: [mm]F Typical Impedance Characteristics:H4: Classification Wave Soldering Profile:H5: Classification Wave ProfileProfile FeaturePreheat- Temperature Min (T smin )- Temperature Typical (T stypical ) - Temperature Max (T smax ) - Time (t s ) from (T smin to T smax )Δ preheat to max Temperature Peak temperature (T p )Time of actual peak temperature (t p )Ramp-down rate - Min - Typical - MaxTime 25°C to 25°C Pb-Free Assembly 100°C 120°C 130°C 70 seconds 150°C max.250°C - 260°C max. 10 secondsmax. 5 second each wave ~ 2 K/s ~ 3.5 K/s ~ 5 K/s 4 minutesSn-Pb Assembly 100°C 120°C 130°C 70 seconds 150°C max.235°C - 260°C max. 10 secondsmax. 5 second each wave ~ 2 K/s ~ 3.5 K/s ~ 5 K/s 4 minutesrefer to EN 61760-1:2006H Soldering Specifications:I Cautions and Warnings:The following conditions apply to all goods within the product series of WE-SDof Würth Elektronik eiSos GmbH & Co. KG:General:All recommendations according to the general technical specifications of the data-sheet have to be complied with.The disposal and operation of the product within ambient conditions which probably alloy or harm the wire isolation has to be avoided.If the product is potted in customer applications, the potting material might shrink during and after hardening. Accordingly to this the product is exposed to the pressure of the potting material with the effect that the core, wire and termination is possibly damaged by this pressure and so the electrical as well as the mechanical characteristics are endanger to be affected. After the potting material is cured, the core, wire and termination of the product have to be checked if any reduced electrical or mechanical functions or destructions have occurred.The responsibility for the applicability of customer specific products and use in a particular customer design is always within the authority of the customer. All technical specifications for standard products do also apply for customer specific products.Washing varnish agent that is used during the production to clean the application might damage or change the characteristics of the wire in-sulation, the marking or the plating. The washing varnish agent could have a negative effect on the long turn function of the product.Direct mechanical impact to the product shall be prevented as the ferrite material of the core could flake or in the worst case it could break. Product specific:Follow all instructions mentioned in the datasheet, especially:•The solder profile has to be complied with according to the technical wave soldering specification, otherwise no warranty will be sustai-ned.•All products are supposed to be used before the end of the period of 12 months based on the product date-code, if not a 100% solderabi-lity can´t be warranted.•Violation of the technical product specifications such as exceeding the nominal rated current will result in the loss of warranty.1. General Customer ResponsibilitySome goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the are-as, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The responsibi-lity for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product characteristics described in the product specification is valid and suitable for the respective customer application or not.2. Customer Responsibility related to Specific, in particular Safety-Relevant ApplicationsIt has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime can-not be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component.3. Best Care and AttentionAny product-specific notes, warnings and cautions must be strictly observed.4. Customer Support for Product SpecificationsSome products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve spe-cific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales person in charge should be contacted who will be happy to support in this matter.5. Product R&DDue to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the customer as per Secti-on 1 and 2 remains unaffected.6. Product Life CycleDue to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a stan-dard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product availability ex-pectancy before or when the product for application design-in disposal is considered.The approach named above does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.7. Property RightsAll the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth Elektronik eiSos GmbH & Co. KG.8. General Terms and ConditionsUnless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth Elektronik eiSos Group”, last version available at .J Important Notes:The following conditions apply to all goods within the product range of Würth Elektronik eiSos GmbH & Co. KG:分销商库存信息: WURTH-ELECTRONICS 744710215。

智能变电站光数字测试仪说明书

智能变电站光数字测试仪说明书

目录1. 前言 (1)1.1关于本说明书 (1)1.2安全须知 (1)1.3产品清单 (2)1.4责任声明 (3)2. 概述 (4)2.1功能说明 (4)2.2性能参数 (4)2.2.1基本性能 (4)2.2.2接收性能 (4)2.2.3发送性能 (5)3. 技术参数 (6)3.1环境条件 (6)3.2机械尺寸及重量 (6)3.3电源 (6)3.4电磁兼容性能 (6)4. 操作说明 (7)4.1外观布局 (7)4.1.1接口 (8)4.1.2指示灯 (8)4.1.3按键 (9)4.2开机关机 (10)4.2.1开机 (10)4.2.2HOME菜单 (10)4.2.3锁定 (10)4.2.4关机 (11)4.3主界面 (13)5. 系统设置 (14)5.1基本设置 (14)5.2连接管理 (14)5.3存储器 (15)5.4备份还原 (16)5.5关于 (17)6. 参数配置 (18)6.1基本参数 (18)6.2SMV发送 (19)6.3GOOSE发送 (25)6.4GOOSE接收 (31)7. 手动试验 (36)7.1扩展菜单 (37)7.1.1SMV映射表 (38)7.1.2开入映射表 (40)7.1.3通道品质 (41)7.1.4状态字 (41)7.1.5异常设置 (42)7.1.6显示开入量 (42)7.1.7设置 (43)7.1.8试验结果 (45)8. 状态序列 (49)8.1状态设置 (49)8.1.1故障计算 (52)8.1.2谐波设置 (53)8.2扩展菜单 (54)9. SMV接收 (56)9.1SMV探测 (56)9.2有效值 (57)9.3波形 (62)9.4相量 (63)9.5序量 (64)9.6功率 (65)9.7谐波 (66)9.8双AD (67)9.9核相 (68)9.10极性 (70)9.11MU延时 (71)9.12报文统计 (72)9.13报文监测 (74)9.13.1SCL配置与报文比较 (74)9.13.2报文录波 (74)10. GOOSE接收 (79)10.1GOOSE探测 (79)10.2实时值 (80)10.3变位列表 (82)10.4报文统计 (84)10.5报文监测 (86)10.6间隔监测 (88)11. 录波分析 (89)11.1录制报文 (89)11.2加载文件 (91)12. 对时 (92)12.1对时功能 (92)12.2授时功能 (93)13. 网络压力 (94)13.1网络压力测试 (94)13.2网络流量统计 (95)14. 光功率 (96)15. SCL编辑器 (97)15.1主界面介绍 (97)15.2SMV/GOOSE控制块信息视图区 (97)15.2.1SMV信息视图 (98)15.2.2GOOSE信息视图 (100)15.3导入SCL或SCX文件 (102)15.4导出配置 (103)15.5SMV/GOOSE信息另存为 (103)15.6SMV/GOOSE信息切换 (104)15.7编辑SMV/GOOSE 信息 (104)15.8查找IED (108)16. 使用示例 (109)16.1示例1——IEC60044-7/8报文发送及GOOSE动作信号接收(手动试验) . 10916.2示例2——通过交换机发IEC61850-9-2,收GOOSE信号(状态序列) (110)16.3示例3——接收IEC60044-7/8报文 (111)16.4示例4——接收IEC61850-9-1/2 报文 (112)16.5示例5——接收GOOSE报文 (113)1. 前言1.1 关于本说明书本说明书提供如何以安全的方式使用GDDT6000智能变电站光数字测试仪的准确信息,说明书中详细介绍了安全、规范的操作要领以及各种测量功能的使用流程,请您在使用协议前完整的阅读完本说明书。

Daikin 100 拓展版 商品说明书

Daikin 100 拓展版 商品说明书

World-class products designedfor AfricaStabilizer Free100TABLE OF CONTENTSAbout DaikinDaikin Makesthe DifferenceInverterTechnologyR32 - GreenRefrigerantBespokeFeaturesProductLine-upUnit OptionsFeatures ListDaikin is a leadinginnovator and provider of advanced, high-quality air-conditioning solutions for residential, commercial and industrial applications.As World’s LeadingAir-conditioning Company, Daikin is committed to delivering air-conditioning solutions that enhance the quality of life all around the world.A diverse multinational company, Daikin Industries Ltd., active in air-conditioning, chemicals and oil hydraulics, was establishedin 1924. With headquarters at Osaka, Japan, the Daikin family has more than 84,000 members, working across 100 production base units and 315 consolidated subsidiaries worldwide. As the world’s sole manufacturer that develops a long line of products,DAIKINfrom refrigerants to air-conditioners,Daikin advocates comfortableliving on the strength of advancedtechnologies.Daikin is present in USA andCanada, Europe and Russia, MiddleEast, Africa, Central Asia, SoutheastAsia, Oceania and Latin America.We aim to serve our customers ineach of these markets by providingoptimal air-conditioning products.12Daikin calls an inverter model that is equipped with a DC motor as DC inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with power neodymium magnets, which enable even greater efficiency, is called a reluctance DC motor.Recipient of Electric Science Promotion Award (Reluctance DC motor for compressor)DAIKIN MAKES THE DIFFERENCE20010080604020Approx. 40% increase 0E ffi c i e n c y (%)DC motorE ffi c i e n c y o f D C m o t o r f o r f a n *(c o m p a r i s o n w i t h a c o n v e n t i o n a l A C m o t o r )3Neodymium magnets are used in the pink-coloured area.The swing compressor can reduce operational vibration and Swing bush Refrigerant gasIntegral piston of blade and rollerFerrite magnetNeodymium magnetWhat is Inverter Technology and how is it different from Non-Inverter Technology?An inverter is a device for convertingfrequency. The technology is used in many home appliances and controls electric voltage, current and frequency. Inverter air-conditioners vary their cooling/heating capacity by adjusting the power supply frequency of their compressors.AHEAD WITH INVERTER TECHNOLOGYAn inverter type air-conditioner adjusts the speed of the compressor to control the refrigerant (gas) flow rate,thereby consuming less current and power. An inverter has precise temperature control and as the set temperature is attained, the unit adjusts its capacity to eliminate any temperature fluctuations.In contrast, non-inverter air-conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors.Non-inverter air-conditioners stops and starts repeatedly. The power consumption and current goes down when the operation stops, but it goes up sharply at the time of restart and thus it has high average power consumption and temperature variations. As a result, inverter air-conditioners are more energy-saving and comfortable than non-inverter air-conditioners.Inverter air-conditioners are able to vary their operating capacity. Non-inverter air-conditioners can only operate at a fixed capacity.Variable capacity operationNon-inverter type air-conditionerPowerInverter power controlCompressorRaise frequencyLower frequencyHigh-speedHigh capacityLow capacityLow-speedPowerCompressorConstant Speed rotationFixed CapacityLet’s take anexample of 1.5 Ton AC. Inverter AC can work from 0.3 to 1.7 ton based on cooling requirement. Non-inverter AC can work at 1.5 ton only (fixed capacity)*.424°Temperature remains constant24°24°24°Inverter air-conditionerScenario: Indoor Temperature: 24°, Set Temperature: 24°25°Compressor stopsTemperature rises and compressorstarts again23°23°25°vvvNon-inverter air-conditionerInverter air-conditioners are more comfortable than non-inverter models.Diagrams are used for illustrative purpose only; actual conditions and scenario may vary from the one shown.Compressor stopsTemperature fluctuatesvWhat are the benefits of Inverter Air-Conditioners?ComfortableInverter air-conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. This gives higher comfort level than the non-inverter air-conditioners.Energy savingAfter the indoor temperature approaches the set temperature, inverter control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy saving than non-inverter models, which must repeatedly start or stop their compressors to maintain theroom temperature.PowerfulInverter air-conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly.5Air is something that surrounds us 24 hours a day. In fact, our existence, as well as earth’s depends on it. At Daikin, the future of the world’s air is our greatest concern. We, the manufacturer of world’s best air-conditioners, are always paving the path to save our environment for next generation.• R-32 – ENERGY EFFICIENTREFRIGERANT – SAVES POWER & MONEYWe phased out all R-22 model and shifted to the green refrigerant R-32. Now, whole world is coming together to find and work on way to address global warming issue. We are also offering worldwide free access to patents for equipment using next generation refrigerant, R-32. Refrigerant choice is a key in saving the ozone layer and reducing global warming.R-32 –BEFRIENDING THE ENVIRONMENT6• DAIKIN IS BRINGING GLOBAL TREND OF ECO-FRIENDLYREFRIGERANT BASED PRODUCTS TO AFRICAR-32 has zero Ozone Depletion Potential (ODP) and Modified Global Warming Potential (GWP) of 472, compared to R-410A’s Modified GWP of 2,027. Also R-32 is a single component refrigerant, which makes it easy to recycle. It is because of these reasons that R-32 offers the lowest total emissions and best overall life cycle climate performance.Most balanced refrigerant=x GWP5001,0001,5002,0002,500675HCFC 22HFC 410A HFC 322,0901,810Charging ratio (%)02040806010012070HCFC 22HFC 410A HFC 3297100Theoretical Modified GWP5001,0001,5002,0002,500472HCFC 22HFC 410A HFC 322,0271,810R-32 is Environment-FriendlyR-32 offers superior performanceBetter life cycle climate performanceZero Ozone Depletion Potential1/3rd Global Warming Potential75% less carbon dioxide emissionsBetter performance at higher temperature as compared to R-22 (low derating)15.3% more cooling as compared to R-410A~30% less refrigerant charging volume as compared to R-410A &R-22~5% more power savings compared toR-410A12345Ozo neEconomySafetyEnergyLCCPHFC410A 12345Ozo neEconomySafetyEnergyLCCPHFO1234YFEconomy12345Ozo neSafetyEnergyLCCPPropane (HFC290)12345Ozo neEconomySafetyEnergy LCCPHFC327LEADING WITH INNOVATIONPatented Streamer Discharge TechnologyRoleFunctionality8Streamer discharge reduces unpleasant smell and virus inside the room cleaning the indoor air.A type of plasma discharge comprising high speed electrons with high oxidation capacity is released within the unit, decomposing odours and harmful gases. High speed electrons are generated and then absorbed within the unit to ensure safety.ECONO OperationPower Consumption Maximum during normaloperationNormal operationMaximum during ECONOoperationECONO operation9LEADING WITH INNOVATIONIndoor Unit Quiet OperationRoleFunctionality10This feature ensures low noise level resulting in sound sleep. It optimises the speed of the airflow according to low noise level to give you uninterrupted comfort.The airflow rate is balanced with sound level to produce minimal noise while under this operation. When the airflow is set to the quiet operation starts and noise from the indoor unit will reduce.Coanda Airflow OperationRoleFunctionalityNote: When POWER CHILL operation is started during COANDA operation, the flap turns downward, allowing the air to blow directly onto people. The combination of COANDA and POWER CHILL operations provides sufficient cooling performance to quickly cool down the room. After POWER CHILL operation is finished, the system automatically returns to COANDA operation.11Coanda airflow operation gives you the bestair-conditioning experience. The powerful air draft does not fall on your head directly, but it is steered upward letting air circulate into the corners of the room creating a comfortable ambience.The horizontal flap is controlled not to blow air directly at people in the room. The airflow rate can be set to any level. However, a low airflow rate may cause cold air to go down and blow on people. If SWING button is pressed during COANDA operation, Coanda operation will be cancelled.When COANDA operation is started during POWER CHILL operation, the system prevents the air from blowing directly onto people.Power Chill OperationLEADING WITH INNOVATIONOperation mode Fan speed Target Temperature COOL H tap + A rpm180CDRY Dry rotating speed + A rpmLowered by 2.50C FAN H tap + A rpm—12Self Diagnosis13The machine auto detects the error and shows the related code on the remote screen. Now you can easily self diagnose the error and report it to your Daikin authorised service centre for a quick resolution.RoleFunctionalityWhen the fault is recognised by the indoor unit it sends the corresponding error code to the remote control, which is displayed on the remote control.1. P ress and hold CANCEL button on the remote for 5 seconds, “00” blinks in the temperature display section. 2. P ress CANCEL button repeatedly until a long beep is produced. The code indication changes as shown below, and notifies with a long beep.Self Diagnosis codesCode DiagnosisA1Indoor unit PCB malfunction E1Outdoor unit PCB malfunction U0Low Refrigerant detection E6Compressor lockL3Electrical box temperature rise E8Input overcurrent detectionU2Low-voltage/over-voltage detection# For More details please refer User Manual /Service ManualFunctionalityOptimizes energy consumption—AC Operation Guarantee (160V~264V)—and protect the electrical components of the AC during power fluctuations.RoleStabilizer inside operationLEADING WITH INNOVATIONThis feature helps stabilize operations by stepping up and stepping down the power voltage during voltage fluctuations.14Stabilizer free operation1515Start living in a cleanenvironment with Daikin filters that absorb harmful germs andgases to provide health-giving air for your family.Titanium apatitephotocatalytic air-purifying filter Absorbs bacteria and viruses while eliminating odour.Silver particle anti-bacterial filterFilter is embedded with silver particles that kills bacteria.PM2.5 & 0.1 filterTraps fine air particles – 0.1 to 2.5 microns in width.Anti-microbial filterIts unique micro-structure andelectrostatic charge provide effective particle capture, and prohibiting growth of mold and mildew on filter media.& 0.1PURE AIR FOR A HEALTHY LIVING16OTHER KEY FEATURESAvailable inIntelligent eyeSpecificationsModel name Indoor unit GTKJ35TV16UZ GTKJ50TV16UZ GTKJ60TV16UZOutdoor unit RKJG35TV16UZ RKJG50TV16UZ RKJG60TV16UZ Power supply1 50Hz 230V1 50Hz 230V1 50Hz 230V(220-240V)(220-240V)(220-240V)Measurement conditions:1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.2. Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.18Specifications19Coanda airflowMeasurement conditions:1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.2. S ound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.Specifications 20Coanda airflowModel name Indoor unit GTHT35TV16XZ GTHT50TV16UZ GTHT60TV16UZ Outdoor unit RHTG35TV16XZ RHTG50TV16UZ RHTG60TV16UZ Power supply1 50Hz 230V1 50Hz 230V1 50Hz 230V(220-240V)(220-240V)(220-240V)Outdoor unit Outdoor unit Outdoor unit1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.2. Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. Cooling and heating capacities above areCoandaairflowSpecifications*T1 Outdoor: 35°CDB T1 Indoor: 27°CDB / 19°CWB21UNIT OPTIONS5 rooms centralised controller NAWiring adopter for time clock / remote control KRP413AB1S + New Optional power adaptor Air purifying filter (PM 0.1)KAF010A503Air purifying filter (PM 2.5)KAF250A502Titanium apatite deodorising air purifying filter KAF970A45Ag-ion filter KAF057A41Anti-microbial filter KAF500A504Air purifying filter (PM 0.1) for streamer Included with the unit in accessories bag Air purifying filter (PM 2.5) for streamer KAF250A505Remote Holder Included with the unit in accessories bagOptional Parts GTHT35/50/60GTKL35/50/60 RHT35/50/60RKLG35/50/605 rooms centralised controller NA NAWiring adopter for time clock / remote control KRP413AB1S + New Optional power adaptor (5.0 &6.0kW only)KRP413AB1S + New Optional power adaptor(5.0 & 6.0kW only)Air purifying filter (PM 0.1)KAF010A503KAF010A503Air purifying filter (PM 2.5)Included with the unit in accessories bag KAF250A502Titanium apatite deodorising air purifying filter KAF970A45KAF970A45Ag-ion filter KAF057A41KAF057A41Anti-microbial filter KAF500A504Included with the unit in accessories bag Air purifying filter (PM 0.1) for streamer NA NAAir purifying filter (PM 2.5) for streamer NA NARemote Holder NA NAOptional Parts GTL28GTQ35/60GTE50 Titanium apatite deodorising air purifying filter KAF970A45KAF970A45KAF970A45 (Optional)Air purifying filter (PM 2.5)KAF250A502KAF250A502Included with the unit in accessoriesbagAir purifying filter (PM 0.1) KAF010A503KAF010A503KAF010A503 (Optional) Ag-ion filter KAF057A41KAF057A41KAF057A41 (Optional) Anti-microbial filter Included with the unit in accessoriesbagKAF500A5KAF500A504 (Optional)2223FEATURES LISTFunctionGTKJ35/50/ 60TV16UZ GTHT35/50/ 60TV16UZ GTKL35/50/ 60TV16XZ GTL28 TV16X2Z GTQ35/60 TV16X2Z GTE50 RKJG35/50/ 60TV16UZRHTG35/50/ 60TV16UZRKLG35/50/ 60TV16XZRLG28 TV16X2Z RQG35/60 TV16X2ZRQG50T e c h n o l o g ySwing compressor ———Rotary comp.———Reluctance DC motor ——— PAM control———C o m f o r t a b l e A i r fl o w New comfort airflow mode (COANDA)Power-airflow dual flaps Wide-angle louversVertical auto-swing (up and down)Horizontal auto-swing (left and right)—— — — —3-D airflow—— — — —C o m f o r t C o n t r o lIndoor unit quiet operation ———Outdoor unit quiet operation —— ———Intelligent eye—— ———Automatic operation (Heating and Cooling)—————Auto fan speed L i f e s t y l eECONO modeInverter powerful operation — — ———New dry mode function POWER CHILL operation—Indoor unit ON/OFF switch Fan onlyC l e a n l i n e s s Patented Streamer Discharge Air Purifier —————Mold proof operation — ————Smell proof operation— Titanium apatite deodorising air purifying filter Option Option Option Option Option Option Ag ion filterOption Option Option Option Option Option Air purifying filter (PM2.5)Option —Option Option Option Option Air purifying filter (PM0.1)—OptionOption Option Option Anti-microbial filterOption—Option Option Option Wipe-clean flat panel (washable)C o n t r o l sPower Display at Indoor unit—————Set Temperature Display at Indoor Unit —————Room Temperature Display at Indoor Unit —————R/C with back light— Luminescent R/C button Indoor temp. display on R/C —— — — —R/C LCD back light OFF — ———Child lock— — — —T i m e r s24-Hr ON/OFF timer————Count up-down ON/OFF timer — —Good Sleep Off Timer——New Good Sleep Off Timer—— — —W o r r y F r e eAuto-restart (after power failure)Stabilizer Inside ———Stabilizer free ———New stabilizer modefor 5.0 & 6.0kWModel—————Self -diagnosis (RC,LED) displayPE Anti-corrosion treatment of outdoor heat exchangerThe present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin MEA. Daikin MEA has compiled the content of thispublication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin MEA explicitly rejects any liability for any direct or indirect damage, inthe broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin MEA.www.daik DMEA21-214Office 332, Regus Mulliner Tower, Ikoyi, Lagos | Contact Number: +234 8065421038E-mail: ********************* Web:Distributed by。

YV100XG中英文对照操作手册

YV100XG中英文对照操作手册

1 32 45 6 78Softwave setting備註欄:1。

直接編輯儲存格2。

使用對話框編輯儲存格3。

使用鍵盤來輸入4。

使用螢幕小鍵盤來輸入5. 使用滑鼠6。

使用觸控式螢幕7。

工具按鍵的顯示/隱藏8。

增減使用者ID及權限3-5 電腦軟/硬體各參數之設定3-6 電腦軟.硬體各參數之設定※電腦軟。

硬體各參數之設定4—1Board :基板參數設定A :PCB X 軸長度 O :吸力確認 1.check 2.nocheckB :PCB Y 軸長度 P:補料的模式 1。

group :拋料後立即補料,直到完備註欄: Board 基板參數設定 IEI-SMD成C :PCB 厚度 Q :預先取料 2。

block:打完一片連板後補料D :生產計畫 1 : 編輯鈕 3。

auto :打完一片後由空閒的吸嘴進E :目前數量 行補料F:計畫產量(到達片數後自動停機) R : Tray 優先 (從tray 先取料著裝,yv88xg 使用) G:連板數量 H :目前產量I :目前最大產量J :基板固定方式:1。

PIN + Push-up 2. Edge clampK :基板固定後的時間 (0~1。

9sec.) L :固定平台下降的高度 (3~30mm)M :基板到達Main stopper 後停止的時間 (0~9。

9sec 。

) N :零件檢查(使用:Use Align 忽略:lgnore Err ) PS:灰色部份為無法使用4—21 2 3 4Offset 單板或連板之原點設定 IEI-SMDOffset1.Boark Origin:原點備註欄:2.Block Offset:連板的原點3.Check Box:切換可否點選Skip4.Pitch Dist:建立多個連板原點4-36 7 1 8 9 2 10 11 3 45 Mount:著裝設定1. Edit: 設定mount執行或不執行2。

Check Box:按下後才能設定要不要Skip3。

HN-100HC说明书

HN-100HC说明书
第2章 安装与接线 .....................................................................................................................3 2.1 安装与接线.................................................................................................................................. 3 2.2 安装方法...................................................................................................................................... 4 2.3 标准连接...................................................................................................................................... 5 2.3.1 位置控制........................................................................................................................... 5 2.3.2 速度控制........................................................................................................................... 6 2.3.3 转矩控制........................................................................................................................... 7 2.4 配线规格...................................................................................................................................... 8 2.5 配线方法...................................................................................................................................... 8 2.6 注意事项...................................................................................................................................... 9

H100I中文资料

H100I中文资料

Key Features:• 1W Output Power• Miniature MiniDIP Case • 3,000 VDC Isolation• Complies to RFI Standards • >2 MHour MTBF• 18 Standard Models• Industry Standard Pin-OutH100I Ultra-Miniature MiniDIP 1W, High Isolation DC/DC Con v ert ersSeriesNew Models!!InputParameterConditionsMin.Typ.Max.UnitsInput Voltage Range 5 VDC Input4.55.0 5.5VDC 12 VDC Input 10.812.013.224 VDC Input21.624.026.4Input FilterInternal CapacitorReverse Polarity Input Current0.3A OutputParameterConditionsMin.Typ.Max.Units Output Voltage Accuracy ±1.0±3.0%Line Regulation For Vin Change of 1%±1.2±1.5%Load Regulation Iout = 20% to 100%±8.0%Ripple & Noise (20 MHz)100mV P - P Output Power Protection 120%Temperature Coeffi cient ±0.01±0.02%/ºC Output Short CircuitMomentary (0.5 Sec.)GeneralParameter ConditionsMin.Typ.Max.Units Isolation Voltage 60 Seconds 3,000VDC Isolation Resistance 500 VDC 1,000M ΩIsolation Capacitance 100 kHz, 1V60100pF Switching Frequency 80kHzEMI/RFIEN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B EnvironmentalParameterConditionsMin.Typ.Max.UnitsOperating Temperature Range -40+25+85ºCOperating Temperature Range Case+100ºCStorage Temperature Range -40+125ºCCoolingFree Air ConvectionHumidityRH, Non-condensing95%PhysicalCase Size 0.50 x 0.40 x 0.27 Inches (12.70 x 10.16 x 6.85 mm)Case Material Non-Conductive Black Plastic (UL94-V0)Weight0.06 Oz (1.8g)Reliability Specifi cationsParameter ConditionsMin.Typ.Max.Units MTBFMIL HDBK 217F , 25ºC, Gnd Benign 2.0MHours Absolute Maximum RatingsParameterConditionsMin.Typ.Max.UnitsInput Voltage Surge (1 Sec) 5 VDC Input-0.77.0VDC12 VDC Input -0.715.024 VDC Input-0.728.0Lead Temperature 1.5 mm From Case For 10 Sec260ºC Internal Power DissipationAll Models450mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.MicroPower Direct292 Page StreetSte DStoughton, MA 02072USAT: (781) 344-8226F: (781) 344-8481E: sales@ W: RoHS CompliantElectrical Specifi cationsSpecifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.Notes:1. Output load regulation is specifi ed for a load change of 20% to 100%.2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin.3. O peration at no-load will not damage these units. How-ever, they may not meet all specifi cations.4. The 5V, 12V and 24V input units do not require external components to operate, but the use of a low ESR capaci-tor (approximately 10 u F , ESR <1.0Ω at 100 kHz) mounted close to the converter input pins is recommended.For 48 VDC input units, an input capacitor should always be used. Dependent upon the application, a value between 4.7 µF and 47 u F should be suffi cient.5. It is recommended that a fuse be used on the input of a power s upply for protection. See the table above for the correct rating.Model Selection GuideNotes:• All dimensions are typical in inches (mm)• Tolerance x.xx = ±0.01 (±0.25)• Pin 1 is marked by a “dot” or indentation on the top of the unitMechanical DimensionsPin ConnectionsModel Number InputOutput Effi ciency (%, Typ)Fuse Rating Slow-Blow(mA)Voltage (VDC)Current (mA)Voltage(VDC)Current (mA, Max)Current (mA, Min)Nominal RangeFull-Load No-Load H101I 5 4.5 - 5.527825 3.3300.0 5.072500H102I 5 4.5 - 5.526725 5.0200.0 4.075500H103I 5 4.5 - 5.5260259.0111.0 2.077500H104I 5 4.5 - 5.52562512.083.3 2.078500H105I 5 4.5 - 5.52572515.066.6 2.078500H106I 5 4.5 - 5.52572524.041.6 2.078500H111I 1210.8 - 13.211616 3.3300.0 5.072200H112I 1210.8 - 13.211216 5.0200.0 4.075200H113I 1210.8 - 13.2109169.0111.0 2.077200H114I 1210.8 - 13.21071612.083.3 2.078200H115I 1210.8 - 13.21071615.066.6 2.078200H116I 1210.8 - 13.21071624.041.6 2.078200H121I 2421.6 - 26.4588 3.3300.0 5.072100H122I 2421.6 - 26.4568 5.0200.0 4.075100H123I 2421.6 - 26.45589.0111.0 2.077100H124I 2421.6 - 26.454812.083.3 2.078100H125I 2421.6 - 26.454815.066.6 2.078100H126I2421.6 - 26.454824.041.62.078100Pin Function 1-Vin 4+Vin 5+Vout 7-Vout(µF Max)220Capacitive LoadOther outputs are available.Contact the factory for details at: sales@MicroPower Direct292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@Derating Curve。

h20s导电银胶规格书

h20s导电银胶规格书

h20s导电银胶规格书H20s导电银胶是一种高性能的导电粘接剂,广泛应用于电子元件的连接和导电性能的提升。

下面是H20s导电银胶的规格书。

一、产品概述:H20s导电银胶是一种具有优异导电性能的高粘接强度胶水,主要由导电颗粒、树脂和溶剂组成。

它可以有效地填充连接电子元件之间的微小间隙,并确保良好的电流传输。

二、产品特点:1.高导电性能:H20s导电银胶具有导电颗粒均匀分布、导电粒子尺寸小等特点,可以提供优异的导电性能,电阻值低,电流传输稳定。

2.优异的粘接强度:H20s导电银胶具有优秀的粘接强度,能够牢固地粘接电子元件,在振动、冲击等环境下保持稳定的连接。

3.良好的耐热性:H20s导电银胶具有良好的耐热性能,能够在高温环境下保持稳定的导电性能和粘接强度。

4.易于加工:H20s导电银胶具有良好的流动性,易于加工成各种形状,可以满足不同电子元件的需求。

5.环保无污染:H20s导电银胶采用无毒环保材料制成,不含有害物质,对环境无污染。

三、产品应用:H20s导电银胶广泛应用于电子元件的连接和导电性能的提升。

主要应用领域包括:1.芯片粘接:H20s导电银胶可用于芯片的连接和粘接,确保芯片之间的电流传输畅通。

2. LED封装:H20s导电银胶可用于LED灯珠的封装,提高灯珠的导电性能和粘接强度。

3.接地线连接:H20s导电银胶可用于接地线与设备的连接,确保良好的接地效果。

4.电子器件粘接:H20s导电银胶可用于各种电子器件的粘接,提高器件之间的连接可靠性和性能。

四、使用方法:1.首先,将H20s导电银胶搅拌均匀,确保导电颗粒分布均匀。

2.然后,将H20s导电银胶涂抹在待连接的表面上,确保涂层均匀厚度。

3.接着,将连接的电子元件放置在涂抹的表面上,轻轻压紧,确保连接牢固。

4.最后,让H20s导电银胶固化,一般需要在室温下静置一段时间,也可以加热固化以加快固化速度。

五、注意事项:1.使用前请确保连接表面干燥、清洁,无灰尘和油污。

NH100单输出和双输出DC DC转换器说明书

NH100单输出和双输出DC DC转换器说明书

Output Voltage:Maximum current 60 d B-60 d B180°-180°0 dB 0°Phase- - - -Gain -------& D UAL OUTPUTSS TABILITYHow to Order:NH 100 D I / 5 / 15 - A /powerconversionFor additional information, call 310.542.8561ore-mail:*******************Industrial & military grade high density DC to DC converters1114121346789101554789101156-C Option-B Option-A Option.040 DIA ± .005.50 / 12.7 MIN..30 / 7.6.38 / 9.7marking surfacebase plate.50 / 12.7MIN..15 / 3.8Tolerances:inches -x.xx x.xxx= ±0.03= ±0.015mm -x.xx.xx = ±0.8= ±0.40Dual OutputSingle Output3.450 / 87.643.100 / 78.753.625 / 92.082.925 / 74.302.750 / 69.862.400 / 60.971.875 / 47.632.575 / 65.411.100 / 27.94.925 / 23.50.750 / 19.05.575 / 14.61.400 / 10.163.450 / 87.643.100 / 78.753.625 / 92.082.925 / 74.302.750 / 69.862.400 / 60.971.875 / 47.632.575 / 65.41.750 / 19.05.575 / 14.613.275 / 83.20Channel2+S 2+OUT 2- OUT 2TRIM 2POWER GOOD Channel1TRIM 1+S 1+ OUT 1- OUT 1SYNC- S 2- S 14-40 UNC-2B THRU 6 PLACES2.873.00.12513TTL2+V IN IN RTN2.375 / 60.332.125 / 53.982.825 / 71.763.125 / 79.383.875 / 98.444.00 / 101.61375 / 60.33125 / 53.98825 / 71.76125 / 79.38875 / 98.440 / 101.61+OUT 1312- OUTPOWER GOOD TRIM +S + OUT - OUTSYNC- S2.873.0013TTL2+V IN IN RTN PAR4-40 UNC-2B THRU 6 PLACESnches / Millimeters 0.125 / 3.18.125 / 3.18Inches / Millimeters /powerconversionNH performance characteristics NHIV. Output Voltage Ripple VIII. Input Current RippleVI. Input Transient ResponseVII. Input Inrush CurrentXI. Turn OnV. Load Transient ResponseX. TTL Turn-offIX. TTL Turn OnI. Input Voltage vs. Output PowerI. Efficiency vs. LoadIII. Efficiency vs. Line VoltageXI. Turn Off / Hold-up TimeTime: 2μS/div 100m A /d i vTime: 2.00ms/divOutput VoltageInput VoltageV = 270 Vdc I = 10 ATime: 500μS/div100V /d i v2.00V /d i vOutput VoltageInput VoltageV = 270 Vdc, V = 5 Vdc, I = 10 ATime: 10 mS/div100V /d i v2.00V /d i vV = 270 Vdc, V = 5 Vdc, I = 10 AV = 270 Vdc, V = 5 Vdc, I = 10 A2 V /d i v2.00V /d i vTime: 200μS/divTTL SignalOutput VoltageTime: 2μS/div 100V /d i v10.0A /d i vInput VoltageInput CurrentTime: 1.00ms/div5 A /d i v100m V /d i vV = 270 Vdc V = 5 VdcOutput VoltageOutput CurrentTime: 500μS/div2.00V /d i v2.00V /d i vTime: 1μS/div20 m V /d i vV = 270 Vdc, V = 5 Vdc, I = 10 AInput Voltage Output Load Input Voltage2V3V5V 15V 12V 28V 24V 20025030035040090%85%80%75%70%65%60%55%2V3V 5V 15V 12V 28V24V 20%40%60%80%100%90%85%80%75%70%65%60%55%2V70 90 110 130 150 170 190100%80%60%40%20%0%3V5V12V24V15V28VV = 270 Vdc, V = 5 Vdc, I = 10 AOutput VoltageOutput VoltageInput VoltageTTL SignalV = 270 Vdc, V = 5 Vdc, I = 10 AV = 270 Vdc, V = 5 Vdc, I = 10 A10A5APerformance Characteristics>> 103/powerconversionNHF150 EMI filtersInches / Millimeters .1251.621.375 / 34.93.625 / 15.88.875 / 22.23.125 / 3.18 4-40 UNC-2B THRU4 PLACES1.50 / 38.11.050 / 26.671.375 / 34.93.450 / 11.43.125 / 3.18-C Option-B Option -A Option-A Option.040 DIA± .005.50 / 12.7 MIN..30 / 7.6.38 / 9.7marking surfacebase plate .50 / 12.7MIN..15 / 3.81234+ IN- IN+ OUT- OUT1.750 0Tolerances:inches -mm-x.xxx.xxxx.xx.xx= ±0.03= ±0.015= ±0.8= ±0.4050 EMI FilterHow to Order:/powerconversionEMI compliance graphs270 V in - 150 watts270 V in - 50 watts270 V in - 150 watts270 V in - 50 watts1201008060402000.03 0.04 0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10kHz1201008060402000.03 0.04 0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10kHz0.01 0.02 0.04 0.06 0.8 0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10MHz120100806040200-200.01 0.02 0.04 0.06 0.8 0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10MHz120100806040200-20Without NHF150With NHF150Mil-STD-461D, CE101Mil-STD-461D, CE102Without NHF150With NHF1505/powerconversionEaton is a registered trademark. All other trademarks are property of their respective owners.Eaton1000 Eaton Boulevard Cleveland, OH 44122 United States © 2017 EatonAll Rights Reserved Printed in USA March 2017ore-mail:*******************。

A8G-107-1-24;中文规格书,Datasheet资料

A8G-107-1-24;中文规格书,Datasheet资料

1A8GReset Rocker SwitchRocker Switch with External Reset Function for High capacity Switching•Energy-saving reset function triggered with external signals.•Incorporates unique switching mechanism switching 20 A with excellent inrush-current durability.•Double-pole, double-throw (DPDT) contact.•Contact gap of 3 mm minimum.•UL and cUL standard approved. Conforms to EN standards.■List of Models■RatingsNote:1.The non-inductive lamp load has an inrush current 10 times steady current.2.The inductive load has a power factor of 0.4 minimum (AC).3.The motor load has an inrush current 6 times steady current.The above ratings were tested under the following conditions:1.Ambient temperature: 20±2 °C2.Ambient humidity: 65±5 %RH3.Switching frequency: 7 times/min.Reset CoilNote:1.Current must not flow for more than 10 s, otherwise the performance of the coil may be affected.2.If a semiconductor element is used to control the reset coil, the residual voltage caused by leakage current must be 2.4 VDC max.RoHS CompliantCautionRefer to PrecautionsRated load Non-inductiveInductiveResistive loadLamp loadInductive loadMotor load250 VAC20A10A8A8ARated voltage(operating voltage range)Reset voltage (coil temperature:20°C±2°C)Rated energized current(coil temperature:20°C±2°C)Coil resistance (coil temperature:20°C±2°C)Permissible voltage applied period 24 VDC±10%(21.6 to 26.4 VDC)21.6 V max.185 mA±20%130 Ω±20%100 ms for min 1 s max.2■Approved StandardsUL, cUL (UL 1054/CSA C22.2 No.55)20A 250 VACKEMA (EN61058-1)20(8)A 250 VAC■CharacteristicsNote:For the codition in individual standard, contact your OMRON sales representative.Contact release time is the period of time during which contacts 1 and 2 and contacts 4 and 5 are released after voltage is imposed on the coil.■OperationPermissible operating frequencyMechanical 20 operations/min max.ElectricalSwitching frequency: 7 times/min.; Coil operation: 7 times/min.Insulation resistance100 M Ω min. (500 VDC)Dielectric strengthBetween terminalsof the same polarity2,000 VAC, 50/60 Hz, for 1 minBetween terminals of the different polarity2,000 VAC, 50/60 Hz, for 1 minBetween chargedmetal parts and the ground terminal4,000 VAC, 50/60 Hz, for 1 min Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction 98 m/s 2 (10G) Destruction 500 m/s 2 (50G) max.DurabilityMechanical Switching operation 100,000 times min.ElectricalSwitching operation 50,000 times min.Contact release time (see note)100 ms max.Ambient operating temperature -10 to +55 °C (with no icing or condensation)Ambient operating humidity45 to 85 %RH3■Dimensions(Unit: mm)Note:Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions.■Operating Characteristics■Panel CutoutNote:Recommended panel material: SPCCConsult your OMRON representative when using a panel with a thickness other than the above.Be sure that play R is the operation side.■Contact FormNote:When 24 VDC is applied to the coil, contacts 2 and 3 and contacts 5 and 6 are ON.A8GOperating force (OF) max.19.6 N {2,000 gf}Panel thickness X Y 1.6 to 3.0 mm34.4 mm 24.4 mm +0.2 0+0.3 0Pl a y REdge-, +:Coil terminals■PrecautionsBe sure to read the Safety precautions common to all Rocker Switches for correct use.分销商库存信息: OMRONA8G-107-1-24。

h20s导电银胶规格书

h20s导电银胶规格书

h20s导电银胶规格书产品名称:H20s导电银胶型号:H20s颜色:银色导电性能:高导电性包装规格:100g/瓶导电银胶是一种用于导电连接和修复电子器件的胶状材料。

H20s导电银胶是一种具有高导电性的银色银胶。

它可以在机械或电子设备的部件之间提供可靠的电流通路,并能够有效传导电力和热量。

以下是H20s导电银胶的详细规格。

1.导电性能:H20s导电银胶具有出色的导电性能。

它提供低电阻以确保良好的电流通路。

其导电率为100部(Ω.cm^-1),可满足高要求的电子应用。

2.外观特征:H20s导电银胶为银色,具有良好的光泽和均匀性。

它能够均匀涂覆在不同形状的表面上,确保导电层的均匀性和稳定性。

3.包装规格:H20s导电银胶以100g/瓶的包装规格提供。

这个大小的包装足够用于多次应用,并方便携带和储存。

4.基底适应性:H20s导电银胶可用于各种基底表面,包括金属、塑料和陶瓷等。

它能够在不同材料之间提供可靠的黏接和导电连接。

5.热稳定性:H20s导电银胶表现出良好的热稳定性能。

它能在高温下长时间工作而不会脱落或降低导电性能。

其工作温度范围为-50℃至150℃,能够适应各种环境条件。

6.化学稳定性:H20s导电银胶对多数化学物质具有良好的耐受性。

它能够在常见的酸、碱和溶剂中长时间保持稳定,不会因化学作用而导致导电性能的减退。

7.使用方法:使用H20s导电银胶时,首先确保表面干净无油污。

然后将导电银胶涂覆在需要连接的部件表面上,可以通过刮板或喷涂等方式均匀涂覆。

等待银胶干燥后,即可进行黏接和导电连接。

总结:H20s导电银胶是一种具有高导电性的银色银胶,能够提供可靠的电流通路。

它具有优异的导电性能、良好的外观特征、适应各种基底表面、良好的热稳定性和化学稳定性等优点。

使用H20s导电银胶可以有效连接和修复电子器件,并满足高要求的电子应用。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

IGBT
V CES = 1000 V I C25 = 40 A V CE(sat) = 3.0 V t fi(typ) = 280 ns
IXGH 20N100IXGT 20N100
G = Gate, C = Collector,E = Emitter,
TAB = Collector
TO-247 AD (IXGH)
Features
•International standard packages JEDEC TO-268 surface and JEDEC TO-247 AD
•High current handling capability •MOS Gate turn-on -drive simplicity Applications
•AC motor speed control •DC servo and robot drives •DC choppers
•Uninterruptible power supplies (UPS)•
Switched-mode and resonant-mode power supplies
•Capacitor discharge Advantages
•High power density
•Suitable for surface mounting •Easy to mount with 1 screw,(isolated mounting screw hole)
98620B (7/00)
Symbol Test Conditions
Characteristic Values
(T J = 25°C, unless otherwise specified)
min.
typ.max.
BV CES I C = 1 mA, V GE = 0 V 1000V V GE(th)I C = 250 m A, V CE = V GE
2.5
5V I CES V CE = V CES T J = 25°C 250m A V GE = 0 V
T J = 125°C
1mA I GES V CE = 0 V, V GE = ±20 V ±100nA V CE(sat)
I C
= I C90, V GE = 15 V
2.2
3.0
V
Symbol Test Conditions Maximum Ratings
V CES T J = 25°C to 150°C
1000V V CGR T J = 25°C to 150°C; R GE = 1 M W 1000V V GES Continuous ±20V V GEM Transient ±30V I C25T C = 25°C 40A I C90T C = 90°C 20A I CM
T C = 25°C, 1 ms
80
A SSOA V GE = 15 V, T VJ = 125°C, R G = 47 W I CM = 40A
(RBSOA)Clamped inductive load, L = 100 m H @ 0.8 V CES
P C T C = 25°C
150
W T J -55 ... +150
°C T JM 150
°C T stg
-55 ... +150
°C Maximum Lead temperature for soldering 300
°C
1.6 mm (0.062 in.) from case for 10 s
Maximum Tab temperature for soldering SMD devices for 10 s 260
°C
M d Mounting torque (M3) 1.13/10Nm/lb.in.
Weight
TO-247 AD 6g TO-268
4
g
TO-268(IXGT)
G
E
(TAB)
IXYS reserves the right to change limits, test conditions, and dimensions. C (TAB)
Preliminary data
Remarks: Switching times may
increase for V CE (Clamp) > 0.8 • V CES ,higher T J or increased R G Remarks: Switching times may
increase for V CE (Clamp) > 0.8 • V CES ,higher T J or increased R G
Symbol
Test Conditions
Characteristic Values
(T J = 25°C, unless otherwise specified)
min.typ.max.
g fs I C = I C90; V CE = 10 V,
12
16S Pulse test, t £ 300 m s, duty cycle £ 2 %I C(ON) V GE = 10V, V CE = 10V
90A C ies 1750
pF C oes V CE = 25 V, V GE = 0 V, f = 1 MHz
100pF C res 38pF Q g 73
nC Q ge I C = I C90, V GE = 15 V, V CE = 0.5 V CES 13nC Q gc 26nC t d(on)30ns t ri 30ns t d(off)350700ns t fi 280700ns E off 3.58.0
mJ t d(on)30ns t ri 30ns E on 0.65mJ t d(off)700ns t fi 520ns E off 6.5
mJ R thJC 0.83K/W
R thCK
(TO-247)
0.25
K/W
Inductive load, T J = 125°C I C = I C90, V GE = 15 V, L = 100 m H V CE = 0.8 V CES , R G = R off = 47 W Inductive load, T J = 25°C
I C = I C90, V GE = 15 V, L = 100 m H,V CE = 0.8 V CES , R G = R off = 47 W limeter
Inches Min.Max.Min.Max.A 19.8120.320.7800.800B 20.8021.460.8190.845C 15.7516.260.6100.640D 3.55 3.650.1400.144E 4.32 5.490.1700.216F 5.4 6.20.2120.244G 1.65 2.130.0650.084H - 4.5-0.177J 1.0 1.40.0400.055K 10.811.00.4260.433L 4.7 5.30.1850.209M 0.4
0.8
0.0160.031N
1.5
2.49
0.0870.102
Dim.
Millimeter Inches Min.Max.Min.Max.A 4.9 5.1.193.201
A 1
2.7 2.9.106.114A 2.02.25.001.010b 1.15 1.45.045.057b 2 1.9 2.1.75.83C .4.65.016.026D 1
3.801
4.00.543.551E 1
5.851
6.05.624.632E 113.313.6.524.535e 5.45 BSC .215 BSC H 18.7019.10.736.752L 2.40 2.70.094.106L1 1.20 1.40.04
7.055L2 1.00 1.15.039.045L3 0.25 BSC .010 BSC L4 3.80 4.10.150.161
TO-268AA (D 3 PAK)
分销商库存信息: IXYS
IXGH20N100。

相关文档
最新文档