Skytile 光板安装指南说明书
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
9.8
595
595
1195
295
595
company
a
Skytile ® Range
Installation Instructions for Skytile ® recessed LED panels
INSTALLATION
ENGLISH
•
R
ead instructions and check that you have all of the tools and accessories required to complete the installation correctly. Isolate power supply before starting the installation.
Standard non-dimmable/dimmable luminaire installation
1. R emove the ceiling tile or tiles from the location where you wish to install the LED panel.
2. W ire the LED driver to the mains supply as indicated in figure 1. If a dimmable variant, connect the dimming control wires(DALI/1-10V/DSI) as shown in figure 2.
3. M ove LED panel into the ceiling aperture and when positioned halfway connect the driver low voltage output to the LED panel (luminaire) as shown in figure 1.a.
4. Position the LED panel into place in the grid ceiling.
5. Reconnect mains power supply and test for operation.
1-10V control wires
DALI control wires
DSI control wires
1200 x 600(44W)
600 x 600(28W/32W/36W)
1200 x 300(36W)
1-10V+DA +1-10V-
DA -
DSI +DSI -Dimming control input
Figure 2.
Wiring connection
Fig.1.a. Luminaire connection
220-240V 50/60Hz / Class II
700mA/27-45V DC / Class III 730mA/30-50V DC / Class III 1050mA/28.5-48V DC / Class III
Fig. 1. Mains Input Cable
Neutral: Blue Live: Brown
Plug & Play Connectors
28W & 36W - 730mA / 32W - 700mA / 44W - 1050mA
Terminal block must comply to EN 60998-2-1 or EN 60998-2-2
28W
600 x 600Luminous Flux 2700*, 3000**Efficacy(lpcW)96*, 107**Colour Temp (K)3000*, 4000**, 4700**
32W
600 x 600Luminous Flux 2800Efficacy(lpcW)88Colour Temp (K)
4200
36W**/44W*
600 x 600**
1200 x 300**
1200 x 600*
Luminous Flux 3500*, 3800**36004400Efficacy(lpcW)97*,106**100100Colour Temp (K)
3000*, 4000**,
4700**
4700
4700
Specifications Ra:80V3_AUGUST_2018_RS
Warnings and cautions
• These products are designed for connection to a mains supply of 220-240V~ 50/60Hz
• The light source of this luminaire is not replaceable: when the light source reaches the end its life the whole of the luminaire must be replaced • This luminaire is suitable for indoor use only.
• It may be necessary to upgrade your MCBs to allow for increased inrush current
• Do not cover with insulation
•
Do not carry out insulation tests with the product connected to the circuit
• To avoid electric shock, serious injury or property damage, isolate power before installing, removing or servicing the product •
It is recommended that luminaires are installed by a qualified electrician and the installation complies with the local current wiring regulations.
•
Any broken or damaged parts should be replaced as soon as possible JCC will not accept responsibility for claims arising from any sub-standard installations
•
It is recommended that the ambient room temperature should not exceed 25°C
Profile & Dimensions
All dimensions in millimetres
Important warranty information
Our Skytile® range is covered by our 7 Year Warranty. That includes 2 Year On-Site support, and our industry-leading 5 Year Commercial Warranty. During the 2 Year On-Site support, we’ll replace or repair any of your Skytile® fittings completely free of charge. Skytile® Base is
supported with a 3 Year Warranty. All warranties must be registered online at /warranty.The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chassis: Product Code/Batch Code.
RoHS
Compliant
IP20/44Skytile Base IP20 only
JCC Lighting Products Ltd., Innovation Centre, Beeding Close, Southern Cross Trading Estate, Bognor Regis, West Sussex, PO22 9TS,
United kingdom .Technical Support: +44(0)1243 838986, Customer Services: +44(0)1243 838999
jcc
LED Panel
Ceiling Fix
Suspension
Wire
Panel Fixing Bracket
Suspension Mounting JCC can also supply a Wire Suspension Kit for applications where a ceiling grid is not available
Surface Mounting JCC can also supply a Surface Mounting Tray.Please ensure there is adequate clearance around the fitting to allow access to the panel.
Mains Supply
LED Panel
Driver Positioning
Ceiling Grid
Mounting options
Suspension bracket fixing points
Wire suspension
Grid ceiling
Surface mounting box
1200 x6001200 x300
600 x600。