自动控制功能(AGC、AVC)运行维护

合集下载

电力系统综合节能的AGC与AVC协调控制策略

电力系统综合节能的AGC与AVC协调控制策略

f u n c t i o n o f o b j e c t i v e s a n d c o r r e s p o n d i n g c o n s t r a i n t f r o m t h e A G C a n d A V C c o n t r o l f u n c t i o n t o p r o v i d e r e f e r e n c e v a l u e c o n s i d e i r n g i n t e g r a t e d e c o n o my . I n t h e p r e d i c t i v e c o n t r o l m o d e , t h e r e a c t i v e a d j u s t i n g i n s t r u c t i o n s or f a d v a n c e d A G C g e n e r a t i o n s w i l l b e
p a ns : i nt e g r a t e d o p t i ma l c o nt r o l mo de l a n d t he pr e d i c t i v e c o n t r o l mo d e 1 . I nt e g r a t e d o pt i ma l c o n t r o l mo de l c o o r d i n a t e a n d us e t he
姜 凯 , 丁晓群 , 许 贤杰 , 陈光 宇 , 李 林z
( 1 . 河 海大 学 能源与 电 气学 院 ,江 苏 南京 2 1 1 1 0 0 :
0 7 1 0 0 0 ) 2 . 华 北 电力大 学 电 气与 电子 工程 学 院 , 河北 保定

【VIP专享】AVC、AGC、一次调频运行管理规定

【VIP专享】AVC、AGC、一次调频运行管理规定

第一篇自动电压控制(AVC)1.概述自动电压控制(AVC:Automatic Voltage Control)采用分级电压控制策略实现系统内无功的合理分配、电压的有效调节是电网经济和可靠运行的有效控制方式。

目前,大多数电力公司通过SCADA或EMS系统来监控全系统范围内的电压,调度中心利用这些信息作出决策来设定电压控制节点的参考整定值或投切无功电压控制设备。

在电厂侧主要由本区域内控制发电机的自动电压调节器(AVR)来完成。

为了维持所希望的目标电压整定值,在电厂端的电压控制中采用自动电压控制装置(AVC),借助装置自身的无功优化算法,得到在目标状态下的当前在线可调机组的目标无功,通过闭环控制调节发电机励磁,实现机组无功的调节。

从而使系统电压逼近或达到目标值。

目的:运行条件改变时,维持电压在允许范围内;正常条件下,改善电网的电压分布,从而使网损最小;2. AVC系统的调度管理2.1.机组AVC装置正常应投入运行,AVC功能的正常投退,必须在机组稳定工况下,值长在得到省调值班调度员的同意后方可发令运行值班人员进行操作。

2.2.设备停役检修影响机组AVC功能正常投运时,应向省调提出申请,经批准后方可进行。

2.3. AVC系统遇有下列紧急情况时,可先将AVC系统退出运行,同时汇报省调调度员,待异常情况处理完毕后与省调联系恢复运行。

1).系统事故危及机组安全。

1).AVC系统发生故障无法正常运行。

2).发电机组检修、启停,或发电机励磁系统不正常、自动励磁调节器未能正常投自动方式(AVR方式)运行。

2.4.开机时,机组并网结束后,检查AVC装置无异常,值长即可向省调汇报申请投入AVC。

2.5.停机时:机组在倒厂用电后,进行发电机解列电气操作前,值长联系省调要求退出AVC。

3. AVC系统的投用与退出3.1. AVC功能的投入步骤:3.1.1.在得值长令后,检查AVC后台机监视画面中无报警。

3.1.2.在AVC后台机监视画面中中检查“AVC上位机运行状态”为“退出”。

agc 概念、avc 概念 -回复

agc 概念、avc 概念 -回复

agc 概念、avc 概念-回复AGC和AVC是两个与经济学密切相关的概念,分别是自动增益调节(AGC)和平均变动成本(AVC)。

本文将详细介绍这两个概念,包括定义、作用、应用领域以及具体案例等。

首先,让我们来了解AGC,即自动增益调节。

AGC是一种自动控制系统,用于调节电子设备中的增益级别,以确保信号的恰当放大。

该技术最初应用于无线电和电话领域,目的是在不同的接收条件下保持信号强度的稳定性。

AGC通过不断监测输入信号的强度并调整放大系数,以确保输出信号的稳定性,无论输入信号的强度如何变化。

在一个传统的AGC系统中,存在两个重要的元素:检测电路和控制电路。

检测电路负责监测输入信号的强度,通常通过电压或功率测量。

控制电路根据检测电路的输出结果,调整放大器的增益,以保持输出信号的稳定性。

AGC的典型示例是收音机或音频放大器,其中AGC系统可确保即使在接收到较弱或较强的信号时,音量保持稳定。

AGC的应用领域非常广泛。

在通信领域,AGC可以保证信号在不同的传输条件下稳定,从而提高接收信号的品质。

在电视、广播和音频设备中,AGC也被广泛应用于调节音量水平。

此外,AGC还在自动驾驶汽车、图像处理和机器人等领域发挥重要作用,以确保设备在不同环境下的稳定性。

接下来,我们将探讨AVC,即平均变动成本。

AVC是一个经济学术语,用于衡量单位产品的变动成本。

它是总变动成本与产量之间的比率。

平均变动成本告诉我们,每增加一单位产量,所需承担的额外成本是多少。

平均变动成本的计算方法非常简单。

首先,计算总变动成本,即生产过程中因变动投入(例如原材料、直接人工、能源等)而发生的成本。

然后,将总变动成本除以产量得出平均变动成本。

AVC在企业的决策中起着重要的作用。

它帮助企业了解每个额外单位产量所带来的变动成本,从而影响企业的生产决策和定价策略。

如果AVC较高,企业增加产量可能会导致较高的变动成本,进而影响企业的盈利能力。

因此,企业需要权衡增加产量和承担额外成本之间的关系,以做出最佳决策。

AVC、AGC、一次调频运行管理规定

AVC、AGC、一次调频运行管理规定

第一篇自动电压控制(A VC)1.概述自动电压控制(A VC:Automatic V oltage Control)采用分级电压控制策略实现系统内无功的合理分配、电压的有效调节是电网经济和可靠运行的有效控制方式。

目前,大多数电力公司通过SCADA或EMS系统来监控全系统范围内的电压,调度中心利用这些信息作出决策来设定电压控制节点的参考整定值或投切无功电压控制设备。

在电厂侧主要由本区域内控制发电机的自动电压调节器(A VR)来完成。

为了维持所希望的目标电压整定值,在电厂端的电压控制中采用自动电压控制装置(AVC),借助装置自身的无功优化算法,得到在目标状态下的当前在线可调机组的目标无功,通过闭环控制调节发电机励磁,实现机组无功的调节。

从而使系统电压逼近或达到目标值。

目的:运行条件改变时,维持电压在允许范围内;正常条件下,改善电网的电压分布,从而使网损最小;2.A VC系统的调度管理2.1.机组A VC装置正常应投入运行,A VC功能的正常投退,必须在机组稳定工况下,值长在得到省调值班调度员的同意后方可发令运行值班人员进行操作。

2.2.设备停役检修影响机组A VC功能正常投运时,应向省调提出申请,经批准后方可进行。

2.3.A VC系统遇有下列紧急情况时,可先将A VC系统退出运行,同时汇报省调调度员,待异常情况处理完毕后与省调联系恢复运行。

1).系统事故危及机组安全。

1).A VC系统发生故障无法正常运行。

2).发电机组检修、启停,或发电机励磁系统不正常、自动励磁调节器未能正常投自动方式(A VR方式)运行。

2.4.开机时,机组并网结束后,检查A VC装置无异常,值长即可向省调汇报申请投入A VC。

2.5.停机时:机组在倒厂用电后,进行发电机解列电气操作前,值长联系省调要求退出A VC。

3.A VC系统的投用与退出3.1.A VC功能的投入步骤:3.1.1.在得值长令后,检查A VC后台机监视画面中无报警。

agc 概念、avc 概念 -回复

agc 概念、avc 概念 -回复

agc 概念、avc 概念-回复AGC概念及其应用AGC,全称为自动增益控制(Automatic Gain Control),是一种电子设备中常见的控制技术。

它的主要作用是在信号处理过程中自动调整输入信号的增益,以确保输出信号在一个合理的范围内,并有效避免过大或过小的信号失真。

在电信领域中,AGC技术广泛应用于无线通信、音频处理以及视频处理等方面。

它能够自动调节信号的增益,使得输入信号在不同条件下都能够保持在一个适当的幅度范围内,从而提高信号传输的质量。

AGC技术通过实时监测输入信号的幅度,并根据预设的参数自动调整放大器的增益,使得输出信号的幅度能够稳定在一个合适的值。

AGC对于解决信号动态范围不一致的问题非常重要。

在无线通信中,信号的强度会受到多种因素的影响,如距离、障碍物以及信号传播路径的多样性等。

如果不进行增益控制,信号可能会因为过大或过小而无法被正确解码或者传输。

通过使用AGC技术,可以减小信号幅度的波动,使得接收端能够更好地辨识信号内容。

在音频处理方面,AGC技术可以有效提高音频质量。

在录音过程中,声音强度可能会发生变化,如人的说话音量的大小不一。

如果不进行增益控制,声音的强度波动可能会导致失真,影响听众的体验。

AGC技术能够根据输入信号的强度自动调整增益,使得输入信号在不同音频强度下都能够保持在一个适当的范围内,从而提高音频的质量。

在视频处理方面,AGC技术也扮演着重要的角色。

在监控摄像头中,由于光照条件的不同,图像的亮度强度也会不断变化。

如果不进行增益控制,图像的亮度可能会过亮或过暗,影响图像质量,甚至导致细节无法清晰辨认。

AGC技术能够自动调整图像的亮度增益,确保图像能够在不同光照条件下都能够保持适当的亮度水平。

综上所述,AGC技术在电信领域的应用非常广泛,对于提高信号质量和减少失真非常关键。

它能够在多种条件下自动调整信号的增益,保证信号能够适应不同动态范围的变化,从而提高通信质量、音频质量和视频质量等。

AGC、AVC、PMU基础知识培训(71页)

AGC、AVC、PMU基础知识培训(71页)

AGC、AVC、PMU基础知识培训(71页)一、自动发电控制(AGC)概述1. AGC的定义自动发电控制(Automatic Generation Control,简称AGC)是指通过自动调节发电机的输出功率,使电网频率和联络线功率控制在规定范围内的技术手段。

AGC在电力系统中起着至关重要的作用,确保了电网的稳定运行。

2. AGC的功能(1)维持电网频率稳定:AGC能够实时监测电网频率,根据频率偏差调节发电机输出功率,使电网频率恢复至额定值。

(2)实现联络线功率控制:AGC根据联络线功率偏差,调整发电机输出功率,确保联络线功率在规定范围内。

(3)优化发电机组运行:AGC根据发电机组的经济性、可靠性等因素,合理分配发电任务,提高发电效率。

3. AGC的基本原理AGC系统主要由三部分组成:测量单元、控制单元和执行单元。

测量单元负责实时监测电网频率和联络线功率;控制单元根据测量数据,计算出发电机输出功率的调整量;执行单元根据调整量,对发电机进行实时调节。

二、自动电压控制(AVC)概述1. AVC的定义自动电压控制(Automatic Voltage Control,简称AVC)是指通过自动调节无功功率,使电网电压控制在规定范围内的技术手段。

AVC对于保障电网电压稳定、提高电能质量具有重要意义。

2. AVC的功能(1)维持电网电压稳定:AVC能够实时监测电网电压,根据电压偏差调节无功功率,使电网电压恢复至额定值。

(2)优化无功功率分配:AVC根据电网运行状况,合理分配无功功率,降低线路损耗,提高电网运行效率。

(3)提高电能质量:AVC通过调节无功功率,改善电网电压波形,降低电压谐波,提高电能质量。

3. AVC的基本原理AVC系统主要由测量单元、控制单元和执行单元组成。

测量单元负责实时监测电网电压;控制单元根据测量数据,计算出无功功率的调整量;执行单元根据调整量,对无功补偿装置进行实时调节。

三、相量测量单元(PMU)概述1. PMU的定义相量测量单元(Phasor Measurement Unit,简称PMU)是一种高精度、实时同步测量电网相量的装置。

光伏电站AGCAVC子站技术规范方案

光伏电站AGCAVC子站技术规范方案

光伏电站AGCAVC子站技术规范方案
一、AGC/AVC子站技术规范
1.AGV和AVC的定义
AGC/AVC子站是一种联合的逆变器,其中AGC代表自动稳定,AVC代
表自动调节。

用于控制太阳能发电站中的电力传输系统,以提高电厂的性
能和智能化管理。

2.AGC/AVC的功能
AGC/AVC子站负责太阳能发电站中电力系统的平衡,提供阻尼、调压、调频、余力等功能,以提高太阳能发电站的效率和安全性。

AGC/AVC子站还可以实现电力系统的自动化管理,它可以对电力系统
的状态进行实时监控,发现可能发生的参数异常,并自动调节电力系统的
参数以实现最优性能。

其次,AGC/AVC子站可以实现网络容量的灵活控制,并通过网络控制
系统来控制网络工作状态,优先保证电力系统的安全性和可靠性。

3.AGC/AVC子站技术要求
(1)AGC/AVC子站的组成
AGC/AVC子站由控制系统、变流器、调谐器和电源等部分组成。

控制
系统包括硬件和软件,变流器主要用于实现功率控制,调谐器主要负责实
现频率调节,电源主要负责系统正常运行。

(2)AGC/AVC子站的参数设定
AGC/AVC子站应根据不同的太阳能发电站系统进行参数的设定,如控制系统的调节速率、保护参数、网络容量要求等。

设备维护管理台账(光伏电站-AGC AVC)

设备维护管理台账(光伏电站-AGC AVC)

规格 金智悠 -102.08 119 113.8 2.5 0.3 38.5 33 46 26 38.5 31 1000
系统主要设备
设备名称
数量
AGC/AVC服务器
1
AGC/AVC子站
1
安全注意事项/危险源辨识: 下达目标值时,必须注意与实际值的叠加作用,切勿随意下达指令
11
12
13
14
15
35kV
16
17
18
须执行国家和电力行业有关规范、标准:
项目 厂家
调节死区 电压调节死区 无功调节死区 功率因数调节死区 并网点目标值无功参考上限定值 并网点目标值无功参考下限定值 并网点目标值电压闭锁上限定值 并网点目标值电压闭锁下限定值 并网点目标值电压最大可调压差 并网点目标值电压调节步长 母线电压闭锁上限 母线电压闭锁下限 母线电压回调上限 母线电压回调下限 母线过电压定值 母线低电压定值 母线过电流定值
异常现象的原因与处置方法:
设备系统管理及维护: 检查内容
维修内容记录 维修日期
检修标准 维修内容记录
维护周期 维修人员
维修内容记录 维修日期
维修内容记录
维修人员
设备维护管理台账
设备系统所属电厂
XXX光伏站
设备系统涉及机组
机组设备
专业
电气 设备系统名
AGC/AVC
KKS编码
Y 0AYG30
设备/系统概述说明:
光伏AGC(光伏有功功率自动调节):当前光伏电站发出的有功功率值和调度下发的目标值进行比较,如果差值太大,AGC将自动调节逆变器的有功功 率限值,实时将当前光伏电站发出的有功调整到目标值附近。AGC控制对象为逆变器。
光伏AVC(光伏电压无功自动调节):当前光伏电站高压侧母线电压实际值和调度下发的目标值进行比较,如果差值太大,AVC将自动调节逆变器的无功 功率限值,实时补偿无功或者吸收无功,实现将电压追平到目标值附近。AVC控制对象为SVG。

AGC、AVC运管规定1

AGC、AVC运管规定1
1.2本规定适用电厂自动发电控制(AGC)、自动电压控制(AVC)子站和机组的接入、运行和检修管理。电厂相关人员应熟悉本规定。
1.3电厂应参照本规定制定本厂的现场运行规程,规范相关的运行、检修工作。
2.
2.1200MW及以上火电机组、40MW及以上非灯泡灌流式水电机组和抽水蓄能机组,应具备AGC功能。
增电压速度实测
减电压速度实测
全厂方式无功分配
是否有电压超调
并网机组自动加入AVC
机组增、减无功闭锁条件是否合理
AVC执行周期
母线电压采样周期
指令的记录和查找功能
说明:
1、开环测试和厂控闭环测试以电厂为主完成,省调自动化值班员予以协助;
2、
3、省调闭环测试以省调为主完成,电厂予以协助。
4、
水电单机、多机加入AGC,能否避开振动区
水电厂综合振动区计算与上送
全厂方式下AGC可调上、下限计算与上送
全厂方式的增、减负荷闭锁:各机组闭锁的与逻辑
5
闭环测试
(在厂控、省调分别闭环时,测试AGC逻辑和响应)
投入逻辑测试(厂控、省调)
退出逻辑测试(厂控、省调)
指令超差测试:AGC退出,负荷不变
省调、厂控、开环、闭环切换无扰动
3.8.2
3.8.3和AGC、AVC有关的自动化数据异常;
3.8.4
3.8.5出线或机组跳闸等影响AGC、AVC的事故;
3.8.6
3.8.7电厂与主网解列为独立电网;
3.8.8
3.8.9AGC、AVC控制异常;
3.8.10
3.8.11程序自动退出;
3.8.12
3.8.13其它紧急情况。
3.8.14
3.8.15

AVCAGC结构原理和注意事项

AVCAGC结构原理和注意事项

AVCAGC结构原理和注意事项AVCAGC(Automatic Volume Control and Automatic Gain Control)是一种音频处理技术,用于调节音频信号的音量和增益,以确保输出信号在恒定的水平或范围内。

它在广播、通信和音频录制等领域中得到广泛应用。

本文将介绍AVCAGC结构的原理和注意事项。

自动音量控制(AVC)负责调节音频信号的音量。

其原理是根据输入信号的音量水平调整输出信号的音量,以确保输出信号的音量水平保持恒定。

AVC的工作原理如下:1.输入信号经过一个电平检测器,该检测器检测输入信号的音量水平。

2.检测到的音量水平被与目标音量进行比较,目标音量是事先设置好的所需输出音量水平。

3.如果检测到的音量低于目标音量,AVC将增加音频信号的增益来增加音量。

4.如果检测到的音量高于目标音量,AVC将减小音频信号的增益来降低音量。

5.经过AVC调节后的音频信号输出到下一个处理步骤。

自动增益控制(AGC)负责调节音频信号的增益。

其原理是根据输入信号的强度调整输出信号的增益,以确保输出信号在恒定的范围内。

AGC的工作原理如下:1.输入信号经过一个增益控制电路,该电路检测输入信号的强度。

2.检测到的强度被与目标强度进行比较,目标强度是事先设置好的所需输出信号强度。

3.如果检测到的强度低于目标强度,AGC将增加音频信号的增益。

4.如果检测到的强度高于目标强度,AGC将减小音频信号的增益。

5.经过AGC调节后的音频信号输出到下一个处理步骤。

注意事项1.系统的设置和参数调整是使用AVCAGC结构的关键。

根据实际应用需求,需要合理设置目标音量和目标强度,以确保输出信号满足预期要求。

2.音频输入的质量对AVCAGC结构的效果有很大影响。

如果输入信号质量较差,如存在噪音或失真,AVCAGC结构可能无法正确调整音频信号的音量和增益。

3.AVCAGC结构可能会引入一定的延迟。

由于信号需要经过多个处理步骤,其中包括电平检测、比较和增益调整等过程,这些过程可能会导致一定的信号延迟。

AVC、AGC、一次调频运行管理规定

AVC、AGC、一次调频运行管理规定

第一篇自动电压控制(AVC )1. 概述自动电压控制(AVC :Automatic V oltage Control )采用分级电压控制策略实现系统内无功的合理分配、电压的有效调节是电网经济和可靠运行的有效控制方式。

目前,大多数电力公司通过SCADA 或EMS 系统来监控全系统范围内的电压,调度中心利用这些信息作出决策来设定电压控制节点的参考整定值或投切无功电压控制设备。

在电厂侧主要由本区域内控制发电机的自动电压调节器(AVR )来完成。

为了维持所希望的目标电压整定值,在电厂端的电压控制中采用自动电压控制装置(AVC ),借助装置自身的无功优化算法,得到在目标状态下的当前在线可调机组的目标无功,通过闭环控制调节发电机励磁,实现机组无功的调节。

从而使系统电压逼近或达到目标值。

目的:运行条件改变时,维持电压在允许范围内;正常条件下,改善电网的电压分布,从而使网损最小;2. AVC 系统的调度管理2.1. 机组AVC 装置正常应投入运行,AVC 功能的正常投退,必须在机组稳定工况下,值长在得到省调值班调度员的同意后方可发令运行值班人员进行操作。

2.2. 设备停役检修影响机组AVC 功能正常投运时,应向省调提出申请,经批准后方可进行。

2.3. AVC 系统遇有下列紧急情况时,可先将AVC 系统退出运行,同时汇报省调调度员,待异常情况处理完毕后与省调联系恢复运行。

1). 系统事故危及机组安全。

1). AVC 系统发生故障无法正常运行。

2). 发电机组检修、启停,或发电机励磁系统不正常、自动励磁调节器未能正常投自动方式(AVR 方式)运行。

2.4. 开机时,机组并网结束后,检查AVC 装置无异常,值长即可向省调汇报申请投入AVC 。

2.5. 停机时:机组在倒厂用电后,进行发电机解列电气操作前,值长联系省调要求退出AVC 。

3. AVC 系统的投用与退出3.1. AVC 功能的投入步骤:在得值长令后,检查AVC 后台机监视画面中无报警。

电网AGC与AVC协调控制方法

电网AGC与AVC协调控制方法

第43卷第15期电力系统保护与控制V ol.43 No.15 2015年8月1日Power System Protection and Control Aug. 1, 2015 电网AGC与A VC协调控制方法于 汀1,2,蒲天骄2,刘广一2,李时光2,赵 聪3,田爱忠4(1.四川大学电气信息学院,四川 成都 610065;2.中国电力科学研究院,北京 100192;3.智能电网教育部重点实验室(天津大学),天津 300072;4.新能源电力系统国家重点实验室(华北电力大学),北京 102206)摘要:电力系统有功功率与无功功率耦合日益紧密,自动发电控制(AGC)与自动电压控制(A VC)相互解耦的模式会影响电网的运行控制效果。

基于AGC与A VC不同的控制周期,在时间尺度上建立了分钟层和秒层两级衔接的AGC与A VC协调控制模式,提出了控制方法。

在分钟层级上,建立有功功率与无功功率联合的最优潮流模型,提出AGC与A VC的联合优化控制方法;在秒层级上,完善AGC与A VC各自的控制策略,提出AGC与A VC的协调校正控制方法。

通过算例验证表明,所提方法在满足AGC与A VC各自控制目标的同时,实现了电网的经济运行,抑制了AGC与A VC的相互影响,促进了AGC与A VC的相互支撑。

关键词:有功功率;无功功率;自动发电控制;自动电压控制;联合优化;协调校正Coordinated control method of AGC and A VC in power gridYU Ting1, 2, PU Tianjiao2, LIU Guangyi2, LI Shiguang2, ZHAO Cong3, TIAN Aizhong4(1. School of Electrical Engineering and Information, Sichuan University, Chengdu 610065, China; 2. China ElectricPower Research Institute, Beijing 100192, China; 3. Key Laboratory of Smart Grid, Tianjin University, Ministry of Education, Tianjin 300072, China; 4. State Key Laboratory for Alternate Electrical Power System withRenewable Energy Sources, North China Electric Power University, Beijing 102206, China)Abstract: With the coupling relationship between active power and reactive power in power system becoming stronger, the control mode that automatic generation control (AGC) and automatic voltage control (A VC) operate separately may influence the control effect. Considering of the different control periods of AGC and A VC, this paper proposes a coordinated control method of AGC and A VC with a connection on the time scale of minute level and second level. On the minute level, an optimal power flow model of active power and reactive power associated together is established, a AGC and A VC associated optimization control method is proposed. On the second level, the respective control strategy of AGC and A VC is improved and a coordinated correction control method of AGC and A VC is proposed. Simulation is made to verify that the method proposed meets the respective control objective of AGC and A VC. At the same time, it can realize the economic operation of power system, restrain the mutual influence of AGC and A VC, and promote the mutual support between AGC and A VC.Key words: active power; reactive power; automatic generation control (AGC); automatic voltage control (A VC);associated optimization; coordinated correction中图分类号:TM77 文献标识码:A 文章编号:1674-3415(2015)15-0042-060 引言自动发电控制(Automatic Generation Control,AGC)和自动电压控制(Automatic V oltage Control,A VC)是电网调度自动化系统的两大核心应用。

AGC_AVC基本原理介绍

AGC_AVC基本原理介绍

AGC_AVC基本原理介绍AGC(Automatic Gain Control)自动增益控制和AVC(Automatic Volume Control)自动音量控制是指一种实时调整音频信号增益或音量的技术。

AGC和AVC是在音频处理中广泛应用的原理,可以确保音频信号在传输过程中的一致性和可听性。

AGC和AVC的基本原理是根据输入信号的强度自动调整放大器的增益或控制输出信号的音量,以确保输出信号保持在一个可接受的水平范围内。

其目的是在不改变音频信号质量的前提下,提高信号的可听性并避免信号过载或失真。

AGC和AVC的实现通常依赖于一个反馈回路,该回路将一部分输出信号返回到输入端,并通过对返回信号的测量调整放大器的增益。

具体实现方式可以有多种,下面介绍一种常见的实现方式。

首先,输入的音频信号经过分析器进行分析,分析器可以测量输入信号的强度。

然后,分析器将测量结果与一个预设的目标值进行比较,这个目标值通常是一个期望的音频信号水平。

根据比较结果,控制器计算出一个误差信号,用来控制放大器的增益。

控制器将误差信号进行滤波和放大处理,然后将其发送到放大器的增益控制电路。

增益控制电路根据控制器提供的误差信号来调整放大器的增益。

如果输入信号强度低于目标值,则增益被增加;如果输入信号强度高于目标值,则增益被减小。

最后,输出信号通过输出放大器进行放大,输出放大器的增益可以根据需要自行调整。

输出信号经过输出放大器后,可以将其与输入信号进行比较,检查输出信号是否符合预设的目标值。

如果输出信号强度过高或过低,则需要调整放大器的增益,这个过程将不断进行,直到输出信号达到预设的目标值。

AGC和AVC在许多应用中都起到了重要的作用。

例如,在广播和音频录制中,AGC和AVC可以确保音频信号的音量在适当的范围内,并避免噪音或失真。

在通信领域,AGC和AVC可以调整接收设备的增益,以适应不同强度的输入信号。

此外,在音频设备和耳机中,AGC和AVC可以自动调整音量,使用户无需手动调整音量。

AGC,AVC系统简介

AGC,AVC系统简介

AGC,AVC系统简介AGC/AVC说明AGC⾃动发电量控制AGC(Automatic Generation Control)是能量管理系统EMS中的⼀项重要功能,它控制着调频机组的出⼒,以满⾜不断变化的⽤户电⼒需求,并使系统处于经济的运⾏状态。

在联合电⼒系统中,AGC是以区域系统为单位,各⾃对本区内的发电机的出⼒进⾏控制。

它的任务可以归纳为如下三项:(1)维持系统频率为额定值,在正常稳态运⾏⼯况下,其允许频率偏差在正负(0.05——0.2)Hz之间,视系统容量⼤⼩⽽定。

(2)控制本地区与其他区间联络线上的交换功率为协议规定的数值。

(3)在满⾜系统安全性约束条件下,对发电量实⾏经济调度控制EDC(Economic Dispatch Control)。

⾃动发电控制( Automatic Generation Control )在电⼒⾏业中,AGC指:⾃动发电控制(AGC, Automatic Generation Control ),是并⽹发电⼚提供的有偿辅助服务之⼀,发电机组在规定的出⼒调整范围内,跟踪电⼒调度交易机构下发的指令,按照⼀定调节速率实时调整发电出⼒,以满⾜电⼒系统频率和联络线功率控制要求的服务。

或者说,⾃动发电控制(AGC)对电⽹部分机组出⼒进⾏⼆次调整,以满⾜控制⽬标要求;其基本功能为:负荷频率控制(LFC),经济调度控制(EDC),备⽤容量监视(RM),AGC性能监视(AGC PM),联络线偏差控制(TBC)等;以达到其基本的⽬标:保证发电出⼒与负荷平衡,保证系统频率为额定值,使净区域联络线潮流与计划相等,最⼩区域化运⾏成本。

历史已有40多年,并在我国20多个省级电⽹得到应⽤.⽬前,绝⼤多数发电⼚的发电机投⼊了有功发电⾃动控制系统(AGC),AGC系统的投⼊运⾏在保证机组安全、可靠运⾏的前提下,⼤⼤地提⾼了电⽹运⾏的安全、可靠性。

单机组AGC控制模式:单机组AGC控制模式有两种:遥控+遥调模式、单⼀遥调模式。

AGCAVC管理规定(130307)

AGCAVC管理规定(130307)

AGC/AVC管理规定一、管理方面1.树立AGC/AVC为中调管理的一类设备。

中调下达的关于AGC/AVC的投退、机组负荷上下限与变负荷速率调整的一切指令,值长必须做好记录,该情况自动化科不予考核。

2.严禁随意调整机组负荷上下限与变负荷速率。

根据机组技术资料与电网公司系统稳定要求,我厂机组负荷上限300MW,下限150MW,变负荷速率5MW/分钟,变压速率0.10~0.2Mpa/分钟。

3.机组并网电负荷达到50%后,必须及时投入协调、一次调频功能,根据调度命令投入AGC/AVC。

4.根据调度指令投入AGC/AVC后,应与调度核对AGC/AVC运行状态、指令等参数,以确定AGC/AVC投入且工作正常。

如投入AGC/AVC 后,发现指令数据无变化或变化范围极小(一般情况指令个位数应随电网参数变化而变化),应及时与调度核对AGC/AVC运行状态、指令等参数。

如存在问题,应履行汇报程序,通知生技部分管电气副部长组织处理。

5.值长在值班记录中做好AGC/AVC投切详细记录,注明退出时间、退出原因、恢复时间等。

营销负责人负责建立AGC/AVC投、切台帐。

6.营销负责人每日查看中调自动化科网站发布的调度运行考核日报表,追踪前一天非计划停运、发电计划曲线、AGC/AVC、一次调频、电压控制投入率、合格率、考核电量情况,发现异常及时检查原因,联系解决。

7.涉及到机组负荷与中调不一致、协调控制系统、一次调频系统、AGC/AVC的缺陷问题,必须汇报至运行、生技部副部长级以上人员、副总师,必要时汇报至厂级领导。

8.在AGC退出情况下,应严格按计划曲线带负荷。

由值班调度员调整的发电计划曲线,当班值长必须详细记录调整原因、起止时刻和调整后的发电计划值。

机组发生故障造成非计划停运或非计划降出力时,运行值长应积极和中调协商修改计划负荷曲线。

9.无论任何原因导致AGC/AVC退出,应在条件允许时,积极主动投入AGC,然后向当值调度员汇报。

AGC、AVC现场运行规程

AGC、AVC现场运行规程

AGC、A VC现场运行规程目录一、概述我司RTU装置为上海惠安公司提供,分为主机屏和采集屏,且含AGC+A VC功能,主机屏在网控室,采集屏在机组保护室。

1、AGC自动装置:AGC是指自动、发电(负荷)、控制。

自动发电控制(AGC)是通过控制发电机有功出力来跟踪电力系统负荷变化,从而维持频率等于额定值,同时满足互联电力系统间按计划要求交换功率的一种控制技术。

基本目标包括使全系统的发电出力和负荷功率相匹配;将电力系统的频率偏差调节到零,保持系统频率为额定值;及控制区域间联络线的交换功率与计划值相等,实现各区域内有功功率的平衡。

2、A VC自动装置AVC是自动电压控制系统,通过控制机组励磁,实现电网电压、无功优化控制的专门装置。

在相关约束条件下,根据接受的目标电压指令,调节机组励磁,从而改变高压侧母线电压,达到控制目标。

目的是提高电网的可靠性和电网运行的经济性,该装置可实现本地和远方调度控制。

二、运行管理规定1、AGC投入、退出1.1、允许投入条件:在CCS模式下,AGC指令与实际功率偏差<30MW,且AGC指令非坏质量。

1.2、退出条件:允许投入条件消失,或AGC指令坏质量,或任意RB发生,或省调退出(脉冲),或运行人员退出。

1.3、投入过程:允许投入条件下,在画面点击“AGC请求”背景变红色,表示请求已经发出。

等省调投入(脉冲)信号一来,AGC已经投入。

1.4、闭锁AGC增:AGC模式下,负荷闭增或当前AGC指令大于负荷上限。

负荷闭增:子系统达到最大或机组负荷指令大于负荷上限或主汽压力偏差(PV-SP)低于-0.6MPa或负荷指令超过实际负荷20MW。

1.5、闭锁AGC减:AGC模式下,负荷闭减或当前AGC指令小于负荷下限。

1.6、负荷闭减:机组负荷指令小于负荷下限或主汽压力偏差(PV-SP)高于0.6MPa或负荷指令低于实际负荷20MW。

1.7、具体实现:通过10ADS (AUTOMAN)功能块,其输入为AGC指令,当AGC已投入信号即(请求已经发出且省调投入(脉冲)信号来)SETAUTO被置1,此时将自动接收省调的AGC指令。

AGC_AVC基本原理介绍

AGC_AVC基本原理介绍

Pimax:参加AGC的第i台机组在当前水头下 最大出力 :参加AGC的n台机组当前水头下 P 最大出力之和 Pi:AGC分配到第i台参加AGC的有功功率 (2) 按等微增率原则分配 实际上,我对等微增率的原理了解不是很深 入,仅了解:水电厂承担的有功功率一定 时,为使总耗水量最小,应按相等的耗量 微增率在各发电机组间分配负荷。
(3) 当地/远方 远方方式时,电压曲线给定值由中调设定, 当地方式时电压曲线/给定值由运行人员通 过画面设定; (4) I母/II母控制 I母控制:AVC按照I母的电压进行控制; II母控制:AVC按照II母的电压进行控制; 可以只选一个,也可以同时选。
3、AVC不可运行条件 (1) 机组处于常规设备控制,该机组自动退 出AVC; (2) LCU故障,该机组自动退出AVC,全长 自动退出AVC; (3) 机组在调相态,该机组自动退出AVC; (4) 分母运行时,若I(II)母退出控制,则连 接在I(II)母的机组自动退出AVC; (5) 母线电压值异常,全厂AVC自动退出; (6) 机组事故时,自动退出AVC,由运行人 员控制;
QUALITY:BOOL,功能块的品质,默认 为OK ALARMTAG:STRING,系统应用定义的 报警记录名 AGCONOFF:BOOL,全厂AGC退出/投入 0=AGC退出 1=AGC投入
谢谢大家!!

(1) 保证至少有一台机组供给厂用电; (2) 满足运行母线对中性点接地的要求; (3) 电站主接线对运行的要求; (4) 各机组的状态和健康水平的因素;
一、AGC、AVC原理
AGC-Automatic Generation Control自动发电 控制 1、AGC的依据 (1) 上游来水量。适用于无调节水库的径流电 厂,使电厂最大限度的利用上游来水量,以 不弃水和少弃水为原则。
相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

注:PageX对应PPT中的页数顺序。

录音注意事项:样例:4P18,应该读为4P幺8504317应该读为:五洞四三幺拐5042应该读为:五洞四两跳(第四声)闸SCADA应读为:思嘎达遥调(tiao)Pagex等不读,以下为录音内容稿正式内容:Page1.欢迎参加《自动控制功能(AGC、AVC)运行维护-PCS9000系统》课程的学习,本课程的学习时长大约为:40分钟。

请点击开始学习按钮进入本课程的学习。

Page2.本课程的制作人员为:韦昌福,来自广西电网电力调度控制中心。

Page3.通过本课程的学习,可以使调度自动化主站运维岗位学员懂得:1、电力系统AGC的基本功能2、电力系统AVC的基本功能掌握:1、AGC功能的运行与维护2、AVC功能的运行与维护Page4课程说明本课程主要介绍了电力系统AGC、AVC功能的基本原理,对PCS9000系统中AGC、AVC使用、维护方法进行讲解,能够指导调度自动化人员熟悉AGC、AVC 功能,帮助调度自动化专业人员开展AGC、AVC的运行与维护工作。

适用于调度自动化主站系统(PCS9000)的调度自动化专业主站运维人员在课程开始之前,我们先做几道测试题看一下你对本课程所讲内容的了解程度Page7课程分为3个章节,第一章是电力系统AGC、AVC介绍、第二章是AGC、AVC 功能运行维护,最后设置总结测试章节对课程知识进行回顾,加强对课程内容的理解。

Page8第一章、电力系统AGC、AVC介绍Page91.1电力系统AGC的基本概念AGC (Automatic Generation Control ):是建立在以计算机为核心的能量管理系统(或调度自动化系统)及发电机组协调控制系统之上并通过高可靠信息传输系统联系起来的远程闭环控制系统。

AGC是建设大规模电力系统,实现自动化生产运行控制的一项最基本、最实用的功能。

AGC集中地反映了电力系统在计算机技术、通信技术和自动控制技术等领域的应用实践和综合水平。

Page101.2 电力系统AGC控制目标1、满足独立电力系统供需实时平衡,使电力系统的发电出力与用电负荷相匹配,维持正常频率,保证控制区域内部的电能质量;2、保证联合电力系统联络线交换功率按交易计划运行,加强联络线控制能力,使整个系统协调稳定运行。

3、维持系统频率在允许误差之内;控制互联电网净交换功率按计划值运行。

Page111.3 电力系统AGC功能原理AGC控制系统从电网调度中心的SCADA服务器中获取所需的实时测量数据,主要数据为区域电网联络线功率偏差和频率偏差等数据。

通过对数据进行分析计算,得出各个AGC机组的出力调节控制值,AGC控制系统通过SCADA服务器向电厂发送控制命令,通过通信通道、厂站端的RTU通讯装置,到达AGC机组控制器,最后再由控制器调节AGC机组出力,实现AGC控制。

Page121.4 电力系统AVC的基本概念AVC:自动电压控制,是指以电网调度自动化系统的SCADA系统为基础,以对电网发电机无功功率、并联补偿设备和变压器有载分接头进行的自动调节为手段,以实现电网电压和无功功率分布满足电网安全、稳定、经济运行为目标的电网调度自动化系统的应用模块或独立子系统。

Page131.5 电力系统AVC控制目标1、网省级AVC应满足枢纽母线电压合格、控制设备满足安全限值等约束条件,尽可能实现无功分层分区平衡,减少全系统网损;2、地区AVC支持以下控制目标:a.110kV/220kV变电站10kV母线电压合格;b.110kV变电站主变功率因数合格;c.省网关口功率因数合格(关口无功满足省网要求);d.220kV变电站220kV母线电压满足省网要求、110kV母线电压合格或满足约束的限值;e.降低网损。

1.6 电力系统AVC功能原理三级自动电压控制原理图如右图:三级控制基于全局电压无功优化计算,以网损最小为优化目标进行优化计算,给出全网最优的无功电压优化目标值。

二级控制由电厂控制、变电站控制和下级协调控制三个控制模块组成一级控制由专门的电厂子站、变电站监控系统完成Page15第二章、AGC、AVC功能运行维护Page162.1 AGC常用画面介绍1、进入AGC控制的主画面“广西电网自动发电控制”,并可实时监视到AGC 状态、机组受控情况、控制方式、ACE统计、ACE控制、CPS1、AGC控制区域;水火电出力、旋转备用、调节上下限、调节备用、调节速率等。

2、“AGC区域状态”,用于显示、修改、控制AGC区域主要的CPS控制运行参数。

3、“联络线新关口”,用于修改、控制本区域与外部区域间的交换计划测点、交换计划给定核计划偏置,以及显示联络线走廊及联络线参数。

4、“水电控制与调节”和“火电控制与调节”,可监视水、火AGC电厂控制器PLC的各种状态。

5、“机组参数表”,用于修改控制区域内各机组参数。

目前可以在线修改的机组参数包括额定容量、调节上限、调节下限、上升速率、下降速率等。

6、“运行告警表”,可查询AGC有关的报警信息。

7、“操作事项表”,可查询AGC有关的操作事项和操作人员信息。

8、“历史信息查询”,可查询AGC的各类统计信息,包括控制命令,CPS统计信息,AGC相关历史信息。

9、“AGC控制计算过程”,可监视AGC实时数据流程,包括频率、交换功率、时差校正、电量校正、ACE积分分量、比例分量、CPS分量、调节功率等。

Page1810、“调节功率”,可监视调节功率(深红色)、ACE(土黄色)、频偏(蓝色)和动态死区(深灰色)的趋势。

当调节功率和动态死区曲线相交时,控制命令将发出。

11、“电厂工况”,可监视某电厂与AGC有关的信息。

12、“联络线监控”,可监视广西AGC控制关口和结算关口每个计算分量及其第二测点的采集刷新状况和计算结果,可监视广西电网主用频率和备用频率采集刷新状况等Page192.2 AGC基本操作1、主要CPS控制参数修改:“AGC区域状态”画面可在线修改ACE死区、辅助调节区、紧急调节区参数,可在线修改“ACE积分增益”、“CPS频率增益”、“ACE积分死区”、“ACE 积分限值”、“ACE恒定时间”、“频偏系数”、“NERC_L10”等操作。

Page202、主备用频率切换操作:点击菜单栏上的“改变域特性”按钮,选择“类型”为主排序选项,确定后找到类型为“系统频率”和“分厂频率”的量测,通过单击左键从下拉菜单中改变量测属性并保存后即可立即完成主备频率切换。

Page213、联络线测点操作:“省际联络线状态”画面可单击左键从“测点选择”域的下拉菜单中在线修改联络线计算点选用的测点,可在线修改测点的恒定时间、最大偏差、上限和下限等参数。

如果需要将某个联络线计算点投退,可以直接用鼠标左键在该点“是否使用”域中进行投退切换。

4、PLC参数操作:“PLC当前状态一”和“PLC当前状态二”画面中授权用户可以在线修改各个PLC的控制模式、默认模式、ACE分担系数、最大命令、命令死区、紧急停反向调节等参数。

5、电厂遥调和控制上下限操作:“**电厂工况”画面中可以通过数据封锁的办法在线修改各个电厂的上传控制上限和控制下限,经过授权的用户可以直接发送该电厂有关的遥调(tiao)和遥控命令。

Page222.3 AGC正常运行监视1、ACE和频率计划值监视:“ACE和频率量测监视主要在“AGC区域状态”、出力偏差表画面完成。

其中ACE分为“南网ACE”域值和“计算ACE”域值,分别取自南网TASE.2传送过来的ACE和根据当地联络线采集数据计算的ACE。

2、控制关口和结算关口监视:采用进去区域的线路有功分量构成控制或结算关口,并对关口计算结果进行监视。

Page233、联络线和计划值监视:在“省际联络线状态”画面中,可观察联络线测量是否有效。

为了提高AGC的可靠性,当某一联络线测量中断时,AGC自动采用第二测点来取代。

SCADA和AGC显示的计划值符号相反,但数值相同。

4、运行状态监视:在正常情况下,通过“出力偏差表”、“自动化值班监视”“AGC区域状态”等画面监视AGC运行状态,其中AGC状态为“RUN”,机组受控情况为“正常运行”,CPS1值实时计算刷新。

5、电厂运行监视正常情况下各PLC的“控制模式”和“默认模式”应一致,“控制模式”和“默认模式”也可以根据电网运行情况修改,如果PLC现场退出AGC运行,该PLC的“控制模式”将处于“WAIT”状态,一旦该厂投入AGC运行,该PLC的“控制模式”将自动转换为“默认模式”的设置。

Page242.4 AGC模型维护1、区域模型区域模型定义了AGC的控制区域,控制区域包含了本区域的所有电厂。

一般来说,只定义一个控制区域对象。

如图所示,点击左边树形列表中的“元件参数输入”,可以看到区域模型是由三个视图所组成的:运行区域ACE有关参数、运行区域报警有关参数以及运行区域其它参数。

Page252、电厂模型电厂控制器PLC定义为自动发电控制AGC计算和发布控制命令的对象,它可以是一台机组,也可以是多台机组的集合。

录入的主要参数包括:电厂名称、PLC名称、输入的PLC调节参与因子、响应测试死区、反向命令延时、紧急控制区停止反向延时、最大控制量、控制命令死区、振动区下限、振动区上限等参数。

3、联络线模型联络线是连接运行区域和相邻区域的输电线路。

所有与AGC运行区域相联的联络线都必须建立模型。

录入的参数包括:联络线名称、首端厂站名称、末端厂站名称、功率量测上限、功率量测下限、功率测点间允许偏差等参数。

Page262.5 AVC常用画面介绍进入AVC控制的主画面“可实时监视到电厂运行监视、变电站运行监视、协调控制运行监视、电压稳定等几个模块。

Page27进入AVC控制的主画面点击进入“电厂运行监视”画面,导航条信息如下Page28在“电厂运行监视”画面,点击母线表中的某一条数据,鼠标右击出现曲线显示菜单,点击曲线显示菜单,就会在母线当日曲线中显示相应的电压曲线值。

Page28AVC主界面变电站运行监视如下:Page29点击协调控制运行监视界面如下:2.6 AVC基本操作1、电厂投入/退出AVC远方控制AVC电厂投入退出与AGC投退模式相同,即只要电厂AVC投入远方,主站侧自动进行闭环控制,无需调度员手动进行操作。

Page312、网省协调、省地协调投入/退出AVC运行中调申请或总调下令投入“网省协调”控制时,以及地调申请投入“省地协调”控制时,进入到AVC主画面:左键单击上图红色方框所示位置之一,在弹出的窗口中选择“用户名”及输入密码,确定后即投入南网总调网省协调控制或玉林贵港省地协调控制。

Page322.7 AVC正常运行监视AVC功能正常运行主要是指电厂、变电站、协调模块处于正常未闭锁状态,电厂投入状态正常,电压处于正常调节范围之内。

相关文档
最新文档