12千伏环网柜(箱)标准化设计定制方案)

合集下载

12kV气体绝缘环网柜技术规范书

12kV气体绝缘环网柜技术规范书

_____________10kV 工程12kV气体绝缘环网柜·技术规范书_____年 __ 月目次1标准技术参数表 ·············································································································2项目需求部分 ················································································································2.1货物需求及供货范围 ······································································································2.2必备的备品备件、专用工具和仪器仪表··················································································2.3图纸资料提交单位·········································································································2.4工程概况 ···················································································································2.5使用条件 ···················································································································2.6项目单位可选技术参数····································································································2.7项目单位技术差异·········································································································3投标人响应部分 ·············································································································3.1技术偏差表红苏电气 ······································································································3.2投标产品的销售及运行业绩·······························································································3.3投标人需提供的设备图纸及资料 ·························································································3.4主要组部件材料 ···········································································································3.5推荐的备品备件、专用工具和仪器仪表··················································································1标准技术参数表投标人应认真逐项填写技术参数响应表中投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。

12~24kV氮气绝缘环网柜的研制

12~24kV氮气绝缘环网柜的研制

操作方便,控制和保护相对简单,成本较低,在二 次配电系统中得到广泛应用,受到供电部门和终端 用户的欢迎。但目前的环网柜大都采用六氟化硫 (SF6)气体作为绝缘和开断介质。而SF6气体虽是一
环网柜的去sF6有2个技术方向:①是环保气
体绝缘环网柜,采用干燥空气或氮气(N2)等气体取
万方数据
高电压技术
代SF6作为绝缘介质,以真空取代sF6作为开断介
给予用户最大的持续运行可靠性。 4)保持环网柜紧凑、小巧灵活和便于安装使 用的特点。 本文通过氮气绝缘环网柜的研发,对环网柜的 几种典型绝缘结构(如间隙绝缘、复合绝缘、支撑绝 缘子、穿墙套管沿面绝缘)的最大电场强度进行了分 析研究和优化,提出了降低电场强度的方法和途径, 研制了12~24 kV氮气绝缘环网柜并通过了型式试 验验证。
000
kV/m,在电场强度集中的位置引入
固体绝缘材料,来达到降低气体中最大电场强度的 目的,这是减少氮气绝缘环网柜相间及对地距离, 提高绝缘性能的重要措施。 根据已有的典型形状电极在纯气隙条件下的 最大电场强度的近似计算式…01,可以推导出典型 电极在固体复合绝缘条件下气隙中绝缘层表面气隙 中的最大电场强度近似计算式,以图1所示圆柱对 圆柱电极为例推导如下。图l(a)为圆柱对圆柱电极 纯气隙绝缘的示意图,其中,为电极半径,d为电 极问净距。图1(b)为圆柱对圆柱电极复合绝缘的示 意图,其中,.-为电极半径,圪为复合绝缘层的外径, 凶为复合绝缘层之间的净距。 设反。。为有复合绝缘层的情况下气隙中位于 绝缘层表面的最大电场强度;丘正为与气隙最大电 场强度处相邻的固体绝缘层内的电场强度:.凸为固 体绝缘材料相对介电常数。近似考虑此处电场方向 垂直于绝缘层表面,则可得
across
field in gas gap to 2~3.Adopting hybrid in-

12kV气体绝缘环网柜技术规范书

12kV气体绝缘环网柜技术规范书

_____________10kV 工程12kV气体绝缘环网柜·技术规范书_____年 __ 月目次1标准技术参数表 ·············································································································2项目需求部分 ················································································································2.1货物需求及供货范围 ······································································································2.2必备的备品备件、专用工具和仪器仪表··················································································2.3图纸资料提交单位·········································································································2.4工程概况 ···················································································································2.5使用条件 ···················································································································2.6项目单位可选技术参数····································································································2.7项目单位技术差异·········································································································3投标人响应部分 ·············································································································3.1技术偏差表投标人填写····································································································3.2投标产品的销售及运行业绩·······························································································3.3投标人需提供的设备图纸及资料 ·························································································3.4主要组部件材料 ···········································································································3.5推荐的备品备件、专用工具和仪器仪表··················································································1标准技术参数表投标人应认真逐项填写技术参数响应表中投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。

12千伏标准化定制环网柜(箱)入网专业检测方案

12千伏标准化定制环网柜(箱)入网专业检测方案

并且试验前后操作力基本相同。 力。不应对开关装置和联锁进行调整。
对手力操动装置,应使用正常的操作手
柄进行试验。
6
防护等级
外壳的防护等级为 IP4X,隔室间防护
验证 等级为 IP2X。
按 DL/T 404 的 6.7 进行。
按 DL/T 404 的 6.8 进行。
测量值应符合企业规定范围。年漏气
对于环保气体绝缘环网柜,可通过


温升试验





回路电阻测量





联锁试验





防护等级 密封试验





√注(2)
充气隔室的压力耐受试



短时和峰值耐受电流试

√注(3)




开断关合试验
√注(1)
√注(1),(3)
内部电弧试验




说明:
1)试验应满足 DL/T 404 的要求。
2)√:进行该试验项。
3)样柜应按照标准化设计的互感器进行配置。
如单元柜已具备全套型式试验报告,则本次标准化设计单元柜样柜需完成试验 项目的最低要求如表 2 所示。
表 2 单元柜样柜试验项目
试验项目
SF6气体绝缘环网 环保气体绝 固体绝缘环 常压密封空气

缘环网柜
网柜
绝缘环网柜
V
F
V
V
V
工频耐受电压试验





雷电冲击耐受电压

12kV环网柜标准化设计定制方案

12kV环网柜标准化设计定制方案
12 千伏环网柜标准化设计 定制方案(2017 版)
12 千伏环网柜标准化设计定制方案(2017 版)
目录
前 言.................................................................................................................................................1 1 概述.................................................................................................................................................2
1.1 额定参数..............................................................................................................................2 1.2 使用条件..............................................................................................................................2 1.3 设备选型..............................................................................................................................2 2 12kV 空气绝缘环网柜....................................................................................................................3 2.1 标准化原则.........................................................................ቤተ መጻሕፍቲ ባይዱ................................................3 2.2 典型结构方案......................................................................................................................3 2.3 一次接口及土建接口 .........................................................................................................7

12kV环网柜技术规范标准

12kV环网柜技术规范标准

12kV环网柜技术规范目录1 规范性引用文件 (1)2 技术参数和性能要求 (2)3 标准技术参数 (11)4 使用环境条件表 (15)5 试验 (15)12kV环网柜技术规范1 规范性引用文件下列文件对于本文件的应用是必不可少的。

凡是注日期的引用文件,仅注日期的版本适用于本文件。

凡是不注日期的引用文件,其最新版本适用于本文件。

GB/T 191 包装储运图示标志(ISO 780-1997,MOD )GB 1094.11 电力变压器第11部分干式变压器(IEC 726-82,EQV)GB 1207 电磁式电压互感器(IEC 60044-2: 2003, MOD )GB 1208 电流互感器 (IEC 60044-1.2001. MOD)GB 1984 高压交流断路器(IEC 62271-100: 2001, MOD)GB 1985 高压交流隔离开关和接地开关(IEC 62271-102: 2002, MOD)GB/T 11022 高压开关设备和控制设备标准的共用技术要求GB 3804 3.6kV~40.5kV 高压交流负荷开关(IEC 60265-1-1998 ,MOD)GB 3906 3.6kV~40.5kV 交流金属封闭开关设备和控制设备(IEC 62271-200-2003,MOD )GB 4208 外壳防护等级(IP代码)(IEC 60529-2001,IDT)GB/T 5465.2 电气设备用图形符号第2部分:图形符号(IDT IEC 60417 DB:2007) GB/T 7354 局部放电测量(IEC 60270-2000,IDT)GB/T 10228 干式电力变压器技术参数和要求GB/T 11022 高压开关设备和控制设备标准的共用技术要求GB 11032 交流无间隙金属氧化物避雷器(IEC 60099-4-2006,MOD)GB/T 12022 工业六氟化硫(IEC 376,376A,376B.MOD)GB/T 12706.4 挤包绝缘电力电缆及附件试验要求(IEC 60502-4-2005,MOD)GB 15166.2 交流高压熔断器:限流式熔断器(IEC 60282-1-2005 ,MOD)GB 16926 高压交流负荷开关熔断器组合电器(IEC 6227-105-2002 ,MOD)GB 50150 电气装置安装工程电气设备交接试验标准DL/T 402 高压交流断路器订货技术条件(IEC 62271-100-2001,MOD)DL/T 403 12-40.5kV高压真空断路器订货技术条件DL/T 404 3.6kV~40.5kV交流金属封闭开关设备和控制设备(IEC 62271一200-2003,MOD)DL/T 486 高压交流隔离开关和接地开关(IEC 62271-102-2002,MOD)DL 538 高压带电显示装置(IEC 61958- 2000-11,MOD )DL/T 593 高压开关设备和控制设备标准的共用技术要求(IEC 60694-2002,MOD)DL/T 621 交流电气装置的接地DL/T 728 气体绝缘金属封闭开关设备订货技术导则(IEC 815-1986,IEC 859-1986) DL/T 791 户内交流充气式开关柜选用导则JB/T 8144.1 额定电压26/35kV及以下电力电缆附件基本技术要求SD 318 高压开关柜闭锁装置技术条件Q/GDW 741 配电网技术改造设备选型和配置原则Q/GDW 742 配电网施工检修工艺规范国家电网公司十八项电网重大反事故措施(修订版)国家电网公司交流高压断路器技术标准、交流隔离开关和接地开关技术标准国家电网公司关于印发《预防12kV~40.5kV交流高压开关柜事故补充措施》的通知国家电网公司关于印发《预防交流高压开关柜人身伤害事故措施》的通知国家电网公司物资采购标准高海拔外绝缘配置技术规范电力设备(交流部分)监造大纲电网设备及材料质量管控重点措施2 技术参数和性能要求2.1 环网柜技术参数环网柜技术参数见技术参数特性表。

环网柜项目规划设计方案

环网柜项目规划设计方案

环网柜项目规划设计方案一、项目背景环网柜作为电力系统的一个重要组成部分,其功能是提供电力系统的分支、联络和保护功能。

随着电力系统的发展和电力负荷的增加,环网柜也需要不断升级和改进,以适应日益复杂的电力系统需求。

本项目旨在对现有环网柜进行升级设计,提高其功能性、安全性和可靠性。

二、项目目标1.提高环网柜的负荷能力,以适应电力负荷的增加。

2.改进环网柜的绝缘性能,提高电力系统的稳定性。

3.优化环网柜的结构设计,提高其承载能力和抗震能力。

4.引入先进的监测、保护和控制装置,提高环网柜的智能化水平。

5.完善环网柜的维护和管理体系,提高其可靠性和可维护性。

三、项目内容1.提高负荷能力:通过增加环网柜的主变容量、升级变压器等措施,提高环网柜的负荷能力。

同时,优化环网柜的接线方式和排布,减小线路损耗,提高供电质量。

2.改进绝缘性能:采用先进的绝缘材料和技术,提高环网柜的绝缘性能。

通过合理设计,减少绝缘配合面积,降低接触电阻,提高系统的稳定性。

3.优化结构设计:通过结构强度分析和抗震设计,使环网柜能够在地震等恶劣环境下保持正常运行。

同时,考虑环网柜的样式和配色,使其在城市环境中更加和谐。

4.引入智能装置:安装先进的监测、保护和控制装置,实现对环网柜的远程监控和操作,提高其自动化水平。

通过智能装置的实时数据采集和处理,提高环网柜的故障诊断能力。

5.完善维护管理体系:建立环网柜的定期维护和检查制度,明确维护人员的职责和操作规范,确保环网柜的正常运行。

同时,建立维护记录和故障分析制度,提高环网柜的可靠性和可维护性。

四、项目实施步骤1.项目前期准备:明确项目目标和任务,成立项目组织机构,制定详细的项目计划和工作流程,分配项目资源。

2.项目需求分析:对现有环网柜进行全面调研和分析,了解其功能和性能缺陷,明确改进要求和技术指标。

3.设计方案制定:根据项目需求和技术指标,制定详细的环网柜设计方案,包括负荷能力提升、绝缘性能改进、结构设计优化、智能装置引入和维护管理体系完善等内容。

12千伏手车式开关柜标准化设计定制方案(2017版)-1

12千伏手车式开关柜标准化设计定制方案(2017版)-1

12kV手车式开关柜标准化设计定制方案(2017版)2017年7月目录前言 (1)1 主要技术参数 (2)1.1 额定参数 (2)1.2 使用条件 (2)2 典型结构方案 (3)2.1 架空进线柜 (3)2.2 电缆进线柜 (13)2.3 电缆出线柜 (16)2.4 分段柜 (21)2.5 隔离柜 (24)2.6 PT柜 (29)2.7 所用变柜 (31)3 一次接口及土建接口 (34)3.1 柜体材质及厚度 (34)3.2 母排规格 (34)3.3 开关柜外形 (35)3.4 通用一次接口 (36)3.4.1 主母线位置 (36)3.4.2 联络母线位置 (37)3.4.3 柜体右侧避让套管最小开孔 (37)3.4.4 小母线室 (40)3.4.5 一次接地排孔 (40)3.4.6 一次接地排 (40)3.4.7 二次接地排贯穿孔 (40)3.4.8 二次接地排 (40)3.4.9 二次过线孔 (41)3.4.10 柜前、柜后拼柜孔 (41)3.4.11 主母线搭接孔 (41)3.4.12 柜顶伸出母线 (43)3.4.13 柜顶母线桥 (43)3.4.14 母线换相 (44)3.5 柜面布置 (45)3.5.1 前、后观察窗 (46)3.5.2 前门尺寸 (46)3.5.3 后门尺寸 (46)3.5.4 门结构及厚度 (46)3.5.5 前门门锁结构 (47)3.5.6 铭牌 (47)3.5.7 指示类牌 (48)3.6 柜体与转运车接口 (48)3.7 柜体装配形式 (49)3.8 防护等级 (49)3.10 土建接口 (49)3.10.1 底板二次电缆过线孔 (49)3.10.2 基础槽钢 (51)3.10.3 一次电缆孔 (51)3.10.4 电缆连接端子 (51)3.11 其它 (54)4 二次接口 (55)4.1 柜内二次端子排 (55)4.2 断路器二次航空插头 (55)4.3 断路器操作电源 (55)4.4 散热风机的控制方式 (55)4.5 仪表门板 (55)4.6 综合保护装置 (56)4.7 计量电度表及接线盒 (63)4.8 小母线 (64)4.9 二次导线规格 (65)4.10 连接片 (66)4.11 二次回路空气开关 (66)4.12 柜内二次穿管固定型式及防火措施 (67)5 关键元器件 (68)5.1 真空断路器及手车 (68)5.2 活门 (68)5.3 功能车 (70)5.4 真空灭弧室 (71)5.5 接地开关 (71)5.6 电流互感器 (71)5.6.1 结构型式、安装位置及最多绕组数 (72)5.6.2 外形及参数 (72)5.7 零序电流互感器 (76)5.8 电压互感器 (76)5.9 所用变压器 (77)5.10 避雷器 (77)5.11 风机配置 (78)5.12 加热器和温湿度控制器 (78)5.13 除湿机/抽湿器 (78)5.14 带电显示器 (78)5.15 开关状态显示仪 (79)5.16 智能终端/合并单元 (79)5.17 电磁锁 (79)5.18 程序锁 (79)5.19 照明灯 (79)5.20 备品备件及工器具 (79)6 特殊机械联闭锁 (81)6.2 断路器手车操作孔挂锁功能 (81)6.3 活门自锁功能 (82)6.4 断路器在工作位置时可实现关门状态下紧急手动分闸功能 (82)6.5 手车室强制关门操作闭锁功能 (82)6.6 上下后盖板(门)之间的闭锁功能 (82)6.7 前下门与接地开关联锁功能 (82)6.8 接地开关与后门闭锁功能 (83)6.9 前后门预留挂锁功能 (83)6.10 接地开关操作手柄防误闭锁功能 (83)6.11 电动与手动操作接地开关之间闭锁功能 (83)附件1 12kV手车式开关柜标准化设计方案参数汇总表 (84)附件2 12kV手车式开关柜标准化设计二次原理图 (84)参考文献 (90)前言国家电网公司正在开展配网标准化建设工作,目前2016年版配电网典设修订工作已基本完成,下一阶段的重点为有关设备的标准化。

12千伏标准化设计手车式开关柜入网专业检测方案

12千伏标准化设计手车式开关柜入网专业检测方案

12千伏标准化设计手车式开关柜入网专业检测方案1.概述为满足国网12kV手车式开关柜标准化设计样机认证试验要求,特制定本方案。

2.适用范围按照国网公司《12千伏手车式开关柜标准化设计定制方案》的要求,完成的6台试制样机,包括3台电缆出线柜、3台架空进线柜,试制方案如表1所示。

表1 样柜试制方案试验认证样柜需完成试验项目的最低要求如表2所示。

表2 样柜试验认证方案3.依据标准GB/T 11022-2011 高压开关设备和控制设备标准的共用技术要求GB/T 3906-2006 3.6 kV~40.5 kV交流金属封闭开关设备和控制设备DL/T 404-2007 3.6 kV~40.5 kV交流金属封闭开关设备和控制设备DL/T 593-2016高压开关设备和控制设备标准的共用技术要求4.试验附录内部电弧试验方法1 内部电弧试验关于试品的准备及试验资料准备1.1 试品准备提供2台以上开关柜,一台作为被试单元,一台作为并联单元,送交实验站检验的样品应处在新和清洁的状态。

1.2 试品准备的注意事项1.2.1 试验前开关设备应处于正常工作位臵,且开关设备和控制设备能够进行正常操作,例如,分闸、合闸,抽出和插入可抽出部件,读取测量仪器和设备监控等。

1.2.2 试品外壳的防护等级应满足IP4X的要求。

1.2.3 燃弧试验过程中,试品应按实际供货形态,不允许额外增加现场实际供货不存在的排气管道等设施。

1.2.4 试品底部电缆孔应加封板。

1.3 试验资料准备按GB/T 11022-2011的要求,委托方在委托时需提供产品的技术条件、设计图纸等文档,且提供能充的图纸应能充分代表试品的部件和零件。

然后,实验室根据委托方提供的相关图纸,对试品结构进行全面确认和拍照,并将确认信息记录、存档,以保证所有试品确认信息可以溯源。

2 内部电弧试验程序2.1 内部电弧试验模拟房及指示器2.1.1 模拟房依据标准GB/T 3906-2006,实验小室由地板、天花板和相互垂直两堵墙壁组成。

12kV、24kV环网柜通用技术规范

12kV、24kV环网柜通用技术规范

(2009年版)国家电网公司物资采购标准(开关柜卷环网柜册)12kV、24kV环网柜通用技术规范(编号:1016006-0000-00)国家电网公司二〇〇九年十二月对应的专用技术规范目录目录1 总则 (3)1.1一般规定 (3)1.2投标人应提供的资格文件 (3)1.3适用范围 (4)1.4对设计图纸、说明书和试验报告的要求 (5)1.5标准和规范 (7)1.6投标人必须提交的技术参数和信息 (8)1.7备品备件 (8)1.8专用工具与仪器仪表 (9)1.9安装、调试、性能试验、试运行和验收 (9)2 结构要求 (9)2.1环网柜技术参数 (9)2.2通用要求 (9)2.3负荷开关(断路器) (14)2.4负荷开关-熔断器组合电器 (15)2.5隔离开关 (15)2.6接地开关 (15)2.7电流互感器 (15)2.8电压互感器 (16)2.9避雷器 (16)2.10母线 (16)3 试验 (16)3.1型式试验 (16)3.2出厂试验 (17)3.2现场交接试验 (17)4 技术服务、设计联络、工厂检验和监造 (18)4.1技术服务 (18)4.2设计联络会 (19)4.3工厂检验和监造 (19)5 一、二次及土建接口要求 (20)5.112K V环网柜要求 (20)5.224K V环网柜要求 (28)1 总则1.1 一般规定1.投标人应具备招标公告所要求的资质,具体资质要求详见招标文件的商务部分。

2.投标人须仔细阅读包括本技术规范(技术规范通用和专用部分)在内的招标文件阐述的全部条款。

投标人提供的12kV、24kV环网柜应符合招标文件所规定的要求。

3.本招标文件技术规范提出了对环网柜的技术参数、性能、结构、试验等方面的技术要求。

4.本招标文件提出的是最低限度的技术要求,并未对一切技术细节做出规定,也未充分引述有关标准和规范的条文,投标人应提供符合本技术规范引用标准的最新版本标准和本招标文件技术要求的全新产品,如果所引用的标准之间不一致或本招标文件所使用的标准与投标人所执行的标准不一致时,按要求较高的标准执行。

12kV、24kV环网柜通用技术规范

12kV、24kV环网柜通用技术规范

(2009年版)国家电网公司物资采购标准(开关柜卷环网柜册)12kV、24kV环网柜通用技术规范(编号:1016006-0000-00)国家电网公司二〇〇九年十二月对应的专用技术规范目录目录1 总则 (3)1.1一般规定 (3)1.2投标人应提供的资格文件 (3)1.3适用范围 (4)1.4对设计图纸、说明书和试验报告的要求 (5)1.5标准和规范 (7)1.6投标人必须提交的技术参数和信息 (8)1.7备品备件 (8)1.8专用工具与仪器仪表 (9)1.9安装、调试、性能试验、试运行和验收 (9)2 结构要求 (9)2.1环网柜技术参数 (9)2.2通用要求 (9)2.3负荷开关(断路器) (14)2.4负荷开关-熔断器组合电器 (15)2.5隔离开关 (15)2.6接地开关 (15)2.7电流互感器 (15)2.8电压互感器 (16)2.9避雷器 (16)2.10母线 (16)3 试验 (16)3.1型式试验 (16)3.2出厂试验 (17)3.2现场交接试验 (17)4 技术服务、设计联络、工厂检验和监造 (18)4.1技术服务 (18)4.2设计联络会 (19)4.3工厂检验和监造 (19)5 一、二次及土建接口要求 (20)5.112K V环网柜要求 (20)5.224K V环网柜要求 (28)1 总则1.1 一般规定1.投标人应具备招标公告所要求的资质,具体资质要求详见招标文件的商务部分。

2.投标人须仔细阅读包括本技术规范(技术规范通用和专用部分)在内的招标文件阐述的全部条款。

投标人提供的12kV、24kV环网柜应符合招标文件所规定的要求。

3.本招标文件技术规范提出了对环网柜的技术参数、性能、结构、试验等方面的技术要求。

4.本招标文件提出的是最低限度的技术要求,并未对一切技术细节做出规定,也未充分引述有关标准和规范的条文,投标人应提供符合本技术规范引用标准的最新版本标准和本招标文件技术要求的全新产品,如果所引用的标准之间不一致或本招标文件所使用的标准与投标人所执行的标准不一致时,按要求较高的标准执行。

12kV24kV环网柜通用技术规范

12kV24kV环网柜通用技术规范

(2009年版)国家电网公司物资采购标准(开关柜卷环网柜册)12kV、24kV环网柜通用技术规范(编号:1016006-0000-00)国家电网公司二〇〇九年十二月对应的专用技术规范目录目录1 总则 (3)1.1一般规定 (3)1.2投标人应提供的资格文件 (3)1.3适用范围 (4)1.4对设计图纸、说明书和试验报告的要求 (5)1.5标准和规范 (7)1.6投标人必须提交的技术参数和信息 (8)1.7备品备件 (8)1.8专用工具与仪器仪表 (9)1.9安装、调试、性能试验、试运行和验收 (9)2 结构要求 (9)2.1环网柜技术参数 (9)2.2通用要求 (9)2.3负荷开关(断路器) (14)2.4负荷开关-熔断器组合电器 (15)2.5隔离开关 (15)2.6接地开关 (15)2.7电流互感器 (15)2.8电压互感器 (16)2.9避雷器 (16)2.10母线 (16)3 试验 (16)3.1型式试验 (16)3.2出厂试验 (17)3.2现场交接试验 (17)4 技术服务、设计联络、工厂检验和监造 (18)4.1技术服务 (18)4.2设计联络会 (19)4.3工厂检验和监造 (19)5 一、二次及土建接口要求 (20)5.112K V环网柜要求 (20)5.224K V环网柜要求 (28)1 总则1.1 一般规定1.投标人应具备招标公告所要求的资质,具体资质要求详见招标文件的商务部分。

2.投标人须仔细阅读包括本技术规范(技术规范通用和专用部分)在内的招标文件阐述的全部条款。

投标人提供的12kV、24kV环网柜应符合招标文件所规定的要求。

3.本招标文件技术规范提出了对环网柜的技术参数、性能、结构、试验等方面的技术要求。

4.本招标文件提出的是最低限度的技术要求,并未对一切技术细节做出规定,也未充分引述有关标准和规范的条文,投标人应提供符合本技术规范引用标准的最新版本标准和本招标文件技术要求的全新产品,如果所引用的标准之间不一致或本招标文件所使用的标准与投标人所执行的标准不一致时,按要求较高的标准执行。

12kV环网柜标准化设计定制方案

12kV环网柜标准化设计定制方案

12千伏环网柜标准化设计定制方案(2017版)目录前言 (1)1 概述 (2)1.1 额定参数 (2)1.2 使用条件 (2)1.3 设备选型 (2)2 12kV空气绝缘环网柜 (3)2.1 标准化原则 (3)2.2 典型结构方案 (3)2.3 一次接口及土建接口 (7)2.3.1 柜宽 (7)2.3.2 柜深 (7)2.3.3 柜高 (7)2.3.4 仪表箱 (7)2.3.5 C相(最前相)母线中心距离前框架W (7)2.3.6 主母线相间距W1 (7)2.3.7 主母线搭接高度H (7)2.3.8 主母线规格 (7)2.3.9 框架前沿至B相一次电缆搭接孔的投影距离K (9)2.3.10 主开关灭弧方式 (9)2.3.11 柜体框架材质 (9)2.3.12 柜体框架材质厚度 (10)2.3.13 门板材质 (10)2.3.14 门板颜色 (10)2.3.15 门板材质厚度 (10)2.3.16 柜体防护等级 (10)2.3.17 电缆室门观察窗 (10)2.3.18 可接最多一次电缆数(每相) (10)2.3.19 一次电缆固定位置 (11)2.3.20 一次电缆接线高度 (11)2.3.21 一次电缆排列方式 (11)2.3.22 一次电缆孔直径 (11)2.3.23 一次电缆孔位置参数 (11)2.3.24 一次接地排 (11)2.3.25 一次接地排孔 (12)2.3.26 地脚开孔 (12)2.3.27 二次过线孔 (13)2.3.28 并柜孔 (13)2.3.29 基础槽钢 (14)2.3.30 压力释放通道方向 (14)3 12kV SF6气体绝缘环网柜 (15)3.1 标准化原则 (15)i3.2 典型结构方案 (15)3.2.1 单元柜方案 (15)3.2.2 共箱型方案 (17)3.2.3 环网箱中环网柜组合方案 (18)3.2.4 预装式变电站中环网柜组合方案 (18)3.3 一次接口及土建接口 (22)3.3.1 柜宽 (22)3.3.2 柜深 (22)3.3.3 柜高 (22)3.3.4 仪表箱 (22)3.3.5 主开关灭弧方式 (23)3.3.6 壳体(气箱)材质 (23)3.3.7 壳体(气箱)材质厚度 (23)3.3.8 柜体框架材质 (23)3.3.9 柜体材质厚度 (23)3.3.10 门板材质 (23)3.3.11 门板材质厚度 (23)3.3.12 柜体防护等级 (23)3.3.13 主母线扩展方式 (23)3.3.14 可接最多一次电缆数(每相) (23)3.3.15 一次电缆接线高度 (23)3.3.16 一次电缆排列方式 (24)3.3.17 一次电缆固定位置 (24)3.3.18 一次电缆孔直径 (24)3.3.19 一次电缆孔位置 (24)3.3.20 熔井排列方式 (25)3.3.21 一次接地排规格 (25)3.3.22 一次接地排贯穿孔 (25)3.3.23 仪表箱二次走线孔 (26)3.3.24 地脚开孔位置 (26)3.3.25 压力释放通道方向 (27)3.3.26 基础槽钢 (27)3.3.27 定制尺寸 (27)3.3.27.1 侧扩方式 (27)3.3.27.2 顶扩方式 (31)3.3.28 环网箱 (33)3.3.28.1 环网箱外形 (33)3.3.28.2 开门所需空间 (34)3.3.28.3 地基接口 (34)4 12kV环保气体绝缘环网柜 (37)4.1 标准化原则 (37)4.2 典型结构方案 (37)4.2.1 单元柜方案 (37)ii4.2.3 环网箱中环网柜组合方案 (37)4.2.4 预装式变电站中环网柜组合方案 (37)4.3 一次接口及土建接口 (39)4.3.1 柜宽 (39)4.3.2 柜深 (39)4.3.3 柜高 (39)4.3.4 仪表箱 (40)4.3.5 主开关灭弧方式 (40)4.3.6 壳体(气箱)材质 (40)4.3.7 壳体(气箱)材质厚度 (40)4.3.8 柜体框架材质 (40)4.3.9 柜体材质厚度 (41)4.3.10 门板材质 (41)4.3.11 门板材质厚度 (41)4.3.12 柜体防护等级 (41)4.3.13 主母线扩展方式 (41)4.3.14 可接最多一次电缆数(每相) (41)4.3.15 一次电缆接线高度 (41)3.3.16 一次电缆排列方式 (41)3.3.17 一次电缆固定位置 (41)4.3.18 一次电缆孔直径 (41)4.3.19 一次电缆孔位置 (41)4.3.20 一次接地排规格 (42)4.3.21 一次接地排贯穿孔 (42)4.3.22 仪表箱二次走线孔 (42)4.3.23 地脚开孔位置 (43)4.3.24 压力释放通道方向 (43)4.3.25 基础槽钢 (43)4.3.26 定制尺寸 (43)4.3.26.1 侧扩方式 (44)4.3.26.2 顶扩方式 (45)4.3.27 环网箱 (46)5 12kV固体绝缘环网柜 (47)5.1 标准化原则 (47)5.2 典型结构方案 (47)5.3 一次接口及土建接口 (55)5.3.1 柜宽 (55)5.3.2 柜深 (55)5.3.3 柜高 (55)5.3.4 仪表箱 (55)5.3.5 主开关灭弧方式 (55)5.3.6 主母线 (55)iii5.3.8 柜体框架材质 (56)5.3.9 柜体板材厚度 (56)5.3.10 门板材质 (56)5.3.11 门板材质厚度 (56)5.3.12 柜体防护等级 (56)5.3.13 每相最多可接一次电缆数 (56)5.3.14 一次电缆接线高度 (56)5.3.15 一次电缆排列方式 (56)5.3.16 一次电缆固定位置 (56)5.3.17 一次电缆安装端相间距 (57)5.3.18 一次电缆孔直径 (57)5.3.19 一次电缆孔位置 (57)5.3.20 主母线扩展方式 (57)5.3.21 扩展母线接线端对地高度 (57)5.3.22 扩展母线接线端中心距柜体前底框架深度 (58)5.3.23 扩展母线套管位置尺寸 (58)5.3.24 扩展母线尺寸 (59)5.3.25 扩展母线套管尺寸 (59)5.3.26 一次接地排规格 (59)5.3.27 一次接地排位置尺寸 (59)5.3.28 柜体并柜形式 (60)5.3.29 多回路柜体并柜尺寸 (60)5.3.30 仪表室二次走线孔 (62)5.3.31 地脚开孔位置 (62)5.3.32 压力释放通道方向 (62)5.3.33 基础槽钢 (63)6 12kV常压密封空气绝缘环网柜 (64)6.1 标准化原则 (64)6.2 典型结构方案 (64)6.2.1 单元柜方案 (64)6.2.2 共箱型方案 (66)6.2.3 环网箱中环网柜组合方案 (66)6.2.4 预装式变电站中环网柜组合方案 (66)6.3 一次接口及土建接口 (68)6.3.1 柜宽 (68)6.3.2 柜深 (68)6.3.3 柜高 (68)6.3.4 仪表箱外形尺寸 (69)6.3.5 主开关灭弧方式 (69)6.3.6 柜体框架材质 (69)6.3.7 柜体材质厚度 (69)6.3.8 门板材质 (69)iv6.3.10 柜体防护等级 (70)6.3.11 主母线扩展方式 (70)6.3.12 可接最多一次电缆数(每相) (70)6.3.13 一次电缆接线高度 (70)6.3.14 一次电缆排列方式 (70)6.3.15 一次电缆固定位置 (70)6.3.16 一次电缆孔直径 (70)6.3.17 一次电缆孔位置 (70)6.3.18 一次接地排规格 (71)6.3.19 一次接地排贯穿孔 (71)6.3.20 仪表箱二次走线孔 (72)6.3.21 地脚开孔 (72)6.3.22 压力释放通道方向 (72)6.3.23 基础槽钢 (73)6.3.24 定制尺寸 (73)6.3.24.1 侧扩方式 (73)6.3.24.2 顶扩方式 (74)6.3.25 环网箱 (75)7 二次接口 (76)7.1 仪表门 (76)7.2 柜内二次端子 (76)8 关键元件及要求 (78)8.1 电流互感器 (78)8.2 零序电流互感器 (78)8.3 电压互感器 (79)8.4 环网箱 (79)8.4.1 环网箱材质 (79)8.4.2 环网箱颜色 (80)8.4.3 环网箱材质厚度 (80)8.5 防凝露措施 (80)8.5.1 结构防凝露措施 (80)8.5.2 电气防凝露措施 (81)8.5.3 加热防凝露措施 (83)8.5.4 关键元件防凝露措施 (83)8.6 环网箱外露标准部件材质 (83)8.7 环网箱外壳防腐措施 (83)8.8 环网箱外壳防尘措施 (83)v前言按照公司“1135”配网运行服务管理战略要求,提高设备选型标准,健全质量控制体系,提升配电网设备耐用性,突出设备好的核心,依据安全可靠、坚固耐用、标准统一、通用互换的原则,全面推进配电设备标准化工作。

12千伏手车式开关柜标准化设计定制方案(2017版)-1

12千伏手车式开关柜标准化设计定制方案(2017版)-1

12kV手车式开关柜标准化设计定制方案(2017版)2017年7月目录前言 (1)1 主要技术参数 (2)1.1 额定参数 (2)1.2 使用条件 (2)2 典型结构方案 (3)2.1 架空进线柜 (3)2.2 电缆进线柜 (13)2.3 电缆出线柜 (16)2.4 分段柜 (21)2.5 隔离柜 (24)2.6 PT柜 (29)2.7 所用变柜 (31)3 一次接口及土建接口 (34)3.1 柜体材质及厚度 (34)3.2 母排规格 (34)3.3 开关柜外形 (35)3.4 通用一次接口 (36)3.4.1 主母线位置 (36)3.4.2 联络母线位置 (37)3.4.3 柜体右侧避让套管最小开孔 (37)3.4.4 小母线室 (40)3.4.5 一次接地排孔 (40)3.4.6 一次接地排 (40)3.4.7 二次接地排贯穿孔 (40)3.4.8 二次接地排 (40)3.4.9 二次过线孔 (41)3.4.10 柜前、柜后拼柜孔 (41)3.4.11 主母线搭接孔 (41)3.4.12 柜顶伸出母线 (43)3.4.13 柜顶母线桥 (43)3.4.14 母线换相 (44)3.5 柜面布置 (45)3.5.1 前、后观察窗 (46)3.5.2 前门尺寸 (46)3.5.3 后门尺寸 (46)3.5.4 门结构及厚度 (46)3.5.5 前门门锁结构 (47)3.5.6 铭牌 (47)3.5.7 指示类牌 (48)3.6 柜体与转运车接口 (48)3.7 柜体装配形式 (49)3.8 防护等级 (49)3.10 土建接口 (49)3.10.1 底板二次电缆过线孔 (49)3.10.2 基础槽钢 (51)3.10.3 一次电缆孔 (51)3.10.4 电缆连接端子 (51)3.11 其它 (54)4 二次接口 (55)4.1 柜内二次端子排 (55)4.2 断路器二次航空插头 (55)4.3 断路器操作电源 (55)4.4 散热风机的控制方式 (55)4.5 仪表门板 (55)4.6 综合保护装置 (56)4.7 计量电度表及接线盒 (63)4.8 小母线 (64)4.9 二次导线规格 (65)4.10 连接片 (66)4.11 二次回路空气开关 (66)4.12 柜内二次穿管固定型式及防火措施 (67)5 关键元器件 (68)5.1 真空断路器及手车 (68)5.2 活门 (68)5.3 功能车 (70)5.4 真空灭弧室 (71)5.5 接地开关 (71)5.6 电流互感器 (71)5.6.1 结构型式、安装位置及最多绕组数 (72)5.6.2 外形及参数 (72)5.7 零序电流互感器 (76)5.8 电压互感器 (76)5.9 所用变压器 (77)5.10 避雷器 (77)5.11 风机配置 (78)5.12 加热器和温湿度控制器 (78)5.13 除湿机/抽湿器 (78)5.14 带电显示器 (78)5.15 开关状态显示仪 (79)5.16 智能终端/合并单元 (79)5.17 电磁锁 (79)5.18 程序锁 (79)5.19 照明灯 (79)5.20 备品备件及工器具 (79)6 特殊机械联闭锁 (81)6.2 断路器手车操作孔挂锁功能 (81)6.3 活门自锁功能 (82)6.4 断路器在工作位置时可实现关门状态下紧急手动分闸功能 (82)6.5 手车室强制关门操作闭锁功能 (82)6.6 上下后盖板(门)之间的闭锁功能 (82)6.7 前下门与接地开关联锁功能 (82)6.8 接地开关与后门闭锁功能 (83)6.9 前后门预留挂锁功能 (83)6.10 接地开关操作手柄防误闭锁功能 (83)6.11 电动与手动操作接地开关之间闭锁功能 (83)附件1 12kV手车式开关柜标准化设计方案参数汇总表 (84)附件2 12kV手车式开关柜标准化设计二次原理图 (84)参考文献 (90)前言国家电网公司正在开展配网标准化建设工作,目前2016年版配电网典设修订工作已基本完成,下一阶段的重点为有关设备的标准化。

(完整word)6南方电网公司12kV固体绝缘环网柜技术规范

(完整word)6南方电网公司12kV固体绝缘环网柜技术规范
5)环网柜上的操作按钮(如有)出厂时应配备透明防护罩;
6)柜体上门应设有横眉可粘贴间隔名称,前门外表面应标有清晰明显的主接线示意图;
a)柜体采用敷铝锌钢板或304不锈钢材质,具有足够良好的防锈性能和机械强度,厚度≥2mm,应有明显的厂家标识,并有防止变形的措施。
b)操作机构可采用弹簧或永磁机构,需进行表面处理,在5%NaCl盐雾气体下可耐受96小时,无变化。
c)固体绝缘主体采用抗老化、抗腐蚀能力强的环氧树脂、硅橡胶等固体绝缘材料,外表面喷涂导电或半导电层,并应可靠接地。
K
按GB/T 11022及DL593规定
16
弹簧操作机构

手动或电动弹簧(操作机构电动机额定功率≤240W)
17
操作电压
V
AC220/110V DC110/48/24V
18
外壳防护等级
IP3X
IP3X
19
柜体防护等级
IP3X
20
一次部件防护等级
IP67
21
整柜局放
pC
≤20
2注:组合电器的额定电流用于负荷开关和所选的熔断器的完整组合电器.
DL/T621交流电气装置的接地
DL/T 814-2013配电自动化系统技术规范
JB/T8754高压成套开关设备和控制设备产品型号编制方法
Q/CSG10012中国南方电网城市配电网技术导则
中国南方电网有限责任公司电力安全工作规程(安监〔2015〕30号)
3
GB/T 2900.1、GB/T 2900.15、GB/T 2900.19、GB/T 2900.20、JB/T 8754和DL/T 402中确立的以及下列术语和定义适用于本标准。
c)类型、额定值和结构相同的所有可移开部件和元件在机械和电气上应有互换性。

3.12kV户内环网柜通用技术规范标准[详]

3.12kV户内环网柜通用技术规范标准[详]

湖北省黄冈电力集体企业2018年电力工程设备材料公开框架招标招标文件12kV环网柜(技术规范专用部分)目录环网柜采购标准技术规范使用说明···························································1 总则··················································································1.1 一般规定···········································································1.2 投标人应提供的资格文件·······························································1.3 适用范围···········································································1.4 对设计图纸、说明书和试验报告的要求·····················································1.5 标准和规范··········································································1.6 投标人必须提交的技术参数和信息························································1.7 备品备件···········································································1.8 专用工具与仪器仪表···································································1.9 安装、调试、性能试验、试运行和验收·····················································2 结构要求··············································································2.1 环网柜技术参数······································································2.2 通用要求···········································································2.3 负荷开关···········································································2.4 负荷开关熔断器组合电器······························································2.5 接地开关···········································································2.6 电流互感器··········································································2.7 电压互感器··········································································2.8 避雷器·············································································2.9 母线···············································································3 试验··················································································3.1 型式试验···········································································3.2 出厂试验···········································································3.3 现场交接试验········································································4 技术服务、工厂检验和监造······························································4.1 技术服务···········································································4.2 工厂检验和监造······································································5 一、二次及土建接口要求································································5.1 12kV环网柜要求······································································1 总则1.1 一般规定1.1.1 投标人应具备招标公告所要求的资质,具体资质要求详见招标文件的商务部分。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档