LBX-III全能漏电保护插头使用及维修指引(第四版)

合集下载

通力电梯技能培训教材系列

通力电梯技能培训教材系列

课程描述目录1.LCE 部件和原理..................................................... - 2 -1.1MINI .......................................................... - 2 -1.2 MONO ......................................................... - 3 -2 LCE 接地线屏蔽线检查.............................................. - 4 -2.1 机房 ........................................................ - 4 -2.2 轿顶 ......................................................... - 9 -3 安全回路检查...................................................... - 11 -3.1 读图方法 .................................................... - 11 -3.1.1 插头名称:............................................. - 11 -3.1.2 页码说明............................................... - 11 -3.1.3 RDF 特殊说明........................................... - 11 -3.1.4 安全回路代号说明: ...................................... - 11 -3.2 安全回路开关测试 ............................................ - 12 -4 LCE 接线检查完好.................................................. - 15 -4.1 机房控制柜电子板: ........................................... - 15 -4.2 轿顶接线盒电子板: ........................................... - 15 -4.3 轿厢 COP 电子板: ............................................ - 15 -4.4 井道网络电子板: ............................................. - 15 -5 LCE MAP的了解及使用 .............................................. - 16 -5.1 MAP的功能: 电源控制照明控制 LCE用户界面 .................. - 16 -5.2 MAP箱中的电子板功能......................................... - 16 -5.3 操作界面的使用(见下图) ...................................... - 18 -6 LCE 了解各电子板的输入输出信号指示灯等.......................... - 18 -1.LCE 部件和原理1.1MINI1.2 MONO2 LCE 接地线屏蔽线检查2.1 机房电源接地线厅门锁接地线机房至轿厢网络屏蔽线接地机房至轿厢LCECCB板220V 电源接地线 LCECPU至驱动器屏蔽线接地电源接地线井道网络电源 251接地线厅门锁接地线机房至轿厢网络接地线机房至轿厢LCECCB板220V电源接地线LCECPU至驱动器屏蔽线接地LCECPU至驱动器屏蔽线接地2.2 轿顶220V插座接地轿门锁接地线风扇照明接地线门机接地线220V插座接地线轿门锁接地线风扇照明接地线门机接地线3 安全回路检查安全回路介绍及安全开关的测试安全回路不通故障的排除3.1 读图方法图中触点状态是电梯正常停在最底层,厅门轿门关闭,断开主电源3.1.1 插头名称:XM – Machine Room 机房XT – Traveling Cable 随行电缆XH – Hoist way 井道XC – Car 轿厢XG – Group 群组3.1.2 页码说明页码在每页右下角图面分区:从左至右1-6 从上至下A-H3.1.3 RDF 特殊说明RDF开关动作时,以下的安全开关会被短路。

漏电保护装置的使用和维护范本(2篇)

漏电保护装置的使用和维护范本(2篇)

漏电保护装置的使用和维护范本漏电保护装置是一种用于检测和防止电气设备漏电的重要设备,它能够有效地保护人身安全和电器设备的正常使用。

为了正确使用和维护漏电保护装置,我们需要了解其适用范围、安装要求、使用注意事项、故障排除和定期维护等内容。

下面将详细介绍漏电保护装置的使用和维护范本。

一、适用范围漏电保护装置主要适用于住宅、商业建筑、工业场所等各种类型的电气系统。

它能够有效地检测电路中的漏电情况,在漏电发生时迅速切断电源,避免人身伤害和设备损坏。

漏电保护装置适用于交流电源系统,其额定电压一般为220V或380V,额定频率为50Hz。

二、安装要求1. 安装位置应尽可能靠近电源进线处,避免过长的电源线路;2. 漏电保护装置应安装在干燥、通风、无腐蚀性气体和有保护罩的场所;3. 漏电保护装置应与电源开关相连,通过切断电源来保护电器设备和人身安全;4. 漏电保护装置的接线要牢固可靠,接地线应与接地装置相连;5. 安装过程中,应按照产品说明书和相关安装规范进行操作。

三、使用注意事项1. 漏电保护装置在使用之前需要进行测试和校准,确保其正常工作;2. 定期检查漏电保护装置的工作状态,发现异常应及时进行维修或更换;3. 漏电保护装置不适用于带浸蚀性介质的场所,以免损坏设备;4. 使用漏电保护装置期间,不得自行拆卸或改变装置的设置参数;5. 在使用漏电保护装置时,应按照正确的操作步骤和使用方法进行操作,避免误操作引起安全事故。

四、故障排除1. 若漏电保护装置在正常使用过程中频繁跳闸,可能是电器设备本身存在漏电问题,需检查设备是否存在漏电或电器线路是否接触良好;2. 若漏电保护装置无法正常工作,可能是装置本身损坏或出现故障,需联系专业人员进行维修或更换;3. 若漏电保护装置无法复位,可能是由于漏电保护装置的电路短路或过载,需检查电源是否过载或短路情况并解决。

五、定期维护1. 漏电保护装置需要定期进行检查和维护,以确保其正常工作;2. 定期检查漏电保护装置的接线是否松动,接触是否良好;3. 定期检查漏电保护装置的灯光指示是否正常,功能是否完好;4. 定期清洁漏电保护装置的表面,避免灰尘和污垢影响其正常工作;5. 若发现漏电保护装置存在损坏或故障,应及时联系专业人员进行维修或更换。

漏电保护器安装及使用管理规定

漏电保护器安装及使用管理规定

漏电保护器安装及使用管理规定
1.安装位置选择:
2.安装方式:
3.接线方法:
漏电保护器需要正确接入电气系统。

主要的接线方法有三线法和四线法。

三线法适用于供电网络没有零线的情况,将漏电保护器的进线与出线分别与相线和地线连接。

四线法适用于有零线的情况,漏电保护器的进线与出线分别与相线、地线和零线连接。

4.定期检测:
5.维护保养:
6.注意事项:
安装和使用漏电保护器时需要注意以下事项:
-不得私自改装、拆除漏电保护器,除非由专业人员进行;
-在安装和使用过程中,应遵循相应的安全操作规程,并配备必要的个人防护设备;
-漏电保护器只能用于低压电器设备,不得用于高压设备;。

漏电保护器故障的分级或分段选择法

漏电保护器故障的分级或分段选择法

漏电保护器主要是用来在设备发生漏电故障时以及对有致命危险的人身触电保护,具有过载和短路保护功能,可用来保护线路或电动机的过载和短路,亦可在正常情况下作为线路的不频繁转换启动之用。

下面就让艾驰商城小编对漏电保护器故障的分级或分段选择法来一一为大家做介绍吧。

当在被保护电网内出现了使漏电保护器永久性动作跳闸的漏电或接地故障以后,可以按照“总网-分支-末端”的先后顺序,首先断开低压电网的各条分支线路,然后只对主干线路试送电并同时投入漏电保护器;或者先拉开低压电网的各分段开关,然后只对靠近电源侧和第一段电网试送电并同时投入漏电保护器。

各主干线路或第一段电网中没有故障,那么漏电保护器就能够正常投入运行。

然后再依次投入分支线路或合上下一个分段开关。

艾驰商城是国内最专业的MRO工业品网购平台,正品现货、优势价格、迅捷配送,是一站式采购的工业品商城!具有10年工业用品电子商务领域研究,以强大的信息通道建设的优势,以及依托线下贸易交易市场在工业用品行业上游供应链的整合能力,为广大的用户提供了传感器、图尔克传感器、变频器、断路器、继电器、PLC、工控机、仪器仪表、气缸、五金工具、伺服电机、劳保用品等一系列自动化的工控产品。

如需进一步了解ABB断路器、施耐德断路器的选型,报价,采购,参数,图片,批发等信息,请关注艾驰商城/。

E4.2N 4000 Ekip Touch LI 三极固定三极针电流保护器产品说明书

E4.2N 4000 Ekip Touch LI 三极固定三极针电流保护器产品说明书
Rated Short-time Withstand Current (Icw) Rated Ultimate ShortCircuit Breaking Capacity (Icu)
Rated Uninterrupted Current (Iu) Release Release Type Short-Circuit Performance Level Standards
Not Available 1SDH001000R0002 1SDH001316R1002
Classifications
ETIM 4 ETIM 5 ETIM 6 ETIM 7
Object Classification Code WEEE Category
EC000228 - Power circuit-breaker for trafo/generator/installation prot. EC000228 - Power circuit-breaker for trafo/generator/installation prot. EC000228 - Power circuit-breaker for trafo/generator/installation prot.
for 1 s 66 kA for 3 s 50 kA (400 V AC) 66 kA (415 V AC) 66 kA (440 V AC) 66 kA (500 V AC) 66 kA (525 V AC) 66 kA (690 V AC) 66 kA
4000 A
Ekip Touch LI EL N
8015644750442 1 piece
8ห้องสมุดไป่ตู้362090
384 mm 371 mm 270 mm

防漏电插座是什么?

防漏电插座是什么?

防漏电插座防漏电插座是指插座不会因为受潮、进水,出现电流泄漏的漏电现象。

背景电走进人类生活的200多年以来,漏电、电火花爆炸、短路等用电事故时有发生。

我国每年触电伤亡人数过万,损失超过200亿元。

游泳池、喷泉漏电伤人,沐浴时触电身亡,小孩触摸插座造成伤害等报道时常见诸报端。

在成都“85后”青年创客周刚创立的阿尔刚雷科技有限公司,不怕水、防漏电的插座已经问世。

周刚自主研发的FS(Fence out Something)绝缘连电技术,解决了传统裸露连电技术“漏电、短路、电弧”三大安全难题,实现了既绝缘又通电。

原理防漏电插座采用选通隔离技术,实现了低压电器插座在导电介质(水)中重复安全连电,其绝缘电阻≥10MΩ、漏电流≤2mA,优于国标GB2099.1—2008、GB1002.2—2012的相应指标;防水等级达到IPX8。

在防水、防潮应用环境中该产品达到国际领先水平。

特点随着家用电器的普及应用,给生活带来了很多便利,但同时也带来很多安全隐患。

权威数据显示,由插座所引发的触电事故呈逐年上升趋势,2014年的数据显示触电事故死亡人数达到8000人。

·强防水:防水等级达到IPX8·防漏电:不会因为插座受潮、进水,出现电流泄漏的漏电现象。

·防短路:防止具有导电性能的液体进入插孔而造成插座短路。

·防电弧:防止在通电状态下,插头与插座在插拔过程中出现电弧情况。

参数电流:10A;16A电压:220V功率:2200W (10A) 3500W(16A)防水等级:IPX8使用须知1、需水下使用者,请购买水下专业连接器2、只能与带有绝缘护套的中国国标插头配套使用3、不能以超出额定电压和最大功率使用4、安装后,未插入指示灯亮或插入指示灯亮,请及时更换5、插座插孔务必保持清洁,插孔内不得有任何异物。

三孔电源保护器说明书

三孔电源保护器说明书
CAx-Online-Generator /cax
Tender specifications /tiplv
last modified:
09/22/2016
3WL1220-3NB36-4GA4-Z B16+C11+C22+K07+K13+P61+R10+R15+R21+S24+S71
● 1 / rated value
Hz
● 2 / rated value
Hz
Operating voltage
● at AC / at 50/60 Hz / rated value
V
Operating current
● at 40 °C / rated value
A
● at 50 °C / rated value
● during operation / minimum
°C
● during operation / maximum
°C
● during storage / minimum
°C
● during storage / maximum
°C
Certificates Equipment marking ● acc. to DIN EN 61346-2 ● acc. to DIN EN 81346-2
10/17/2016
Subject to change without notice © Copyright Siemens AG
● at 415 V / rated value
kA
● at 500 V / rated value
kA
● at 690 V / rated value

使用者指南1

使用者指南1

`IP CONF4使用者指南及管理員指南V1.0 Version金葉科技2007-05-07重要安全說明當您使用電腦裝置時,請務必遵守下列安全預防措施,以減低火災、觸電及傷害人體的風險。

z閱讀並瞭解所有說明。

z遵守裝置上標記的所有警告及說明。

z執行安裝時必須符合所有的國家配線規定。

z此裝置連接的插座必須安裝在裝置附近,且必須可以便於隨時使用。

z此裝置若浸入水中,可能會造成危險。

為避免觸電的可能性,請勿在泡澡、淋浴中或身體未幹時使用此裝置。

如果您不慎將裝置落入水中,請先拔除所有插頭後再拾起。

在此裝置完全乾燥之前,請勿重新聯機。

z避免在所在區域發生雷雨時使用此裝置,雷暴雨的閃電有造成危險的些微可能性。

緊急通話應該簡短。

即使已安裝防護措施來限制進入家中或工作場合的電力突波,但仍無法完全阻絕閃電造成的影響。

z如果您懷疑天然瓦斯外泄,請立即通報,但使用電話時請遠離有問題的區域。

IPCONF4的電子接點可能會產生小火花,而這些小火花可能會引燃高濃度的瓦斯。

z請勿將任何種類的物件透過插槽推入IP CONF4,因為它們可能會接觸到導致觸電風險的危險電壓端或短路零件。

請勿將任何液體潑灑到電話上面,若不慎遭液體潑灑,請聯絡服務人員。

z為了減低觸電危險,請勿拆解IP CONF4,開啟或移除覆蓋可能會使您暴露在危險的電壓中。

使用未正確重新組裝的裝置可能會導致觸電。

如果您的電話裝置無法正常運作,請參閱說明如何聯機服務的一節。

支援電話號碼可以在本手冊封面背後找到。

z請勿在雷暴雨期間安裝電話線路。

z請勿在潮濕的場所安裝電話插座,除非該插座是特別針對潮濕場所而設計。

z請勿碰觸絕緣的電話線路或端子,除非電話線已從網路介面中斷連接。

z務必小心安裝或更改電話線。

妥善保存上述安全說明目錄一、歡迎使用 (6)二、概觀 (6)三、IP CONF4功能: (6)3.1軟體功能 (6)3.2硬體功能 (7)四、產品安裝 (7)4.1包裝內容 (7)4.2設備連接 (8)4.2.1 有IP分享器(路由器)的接法: (8)4.2.2 沒有IP分享器的接法 (8)4.3狀態顯示 (9)4.3.1 LCD狀態顯示 (9)4.3.2 LED指示燈 (10)五、使用IP CONF4 (10)5.1設備按鍵 (10)5.1.1 IP Conf4按鍵示意圖 (10)5.1.2 IP Conf4主機按鍵功能說明 (10)5.1.3 IP CONF4子機按鍵功能說明 (12)5.2撥打電話 (12)5.2.1直接撥號 (12)5.2.2間接撥號 (12)5.2.3撥出兩路電話 (12)5.3接聽來電 (12)5.3.1接聽第一路來電 (13)5.3.2接聽第二通來電 (13)5.4保留/切換通話 (13)5.5通話靜音 (13)5.6重撥 (13)5.7音量調整 (13)六、IP CONF4按鍵設定 (13)6.1P HONE B OOK(電話簿) (14)6.2C ALL H ISTORY(通話記錄) (14)6.3P HONE S ETTING(IP CONF4設定) (14)6.3.1 Call Forward(來電轉接) (14)6.3.2 Do Not Disturb(來電拒接) (15)6.3.3 Alarm setting(鬧鐘設定) (15)6.3.4 Date/Time Setting(時間設定) (15)6.3.5 Volume&Gain(音量設定) (16)6.3.6 Ringer(鈴聲設定) (16)6.3.7 Auto Dial(自動撥號) (16)6.4N ETWORK(網路設定) (16)6.4.2 LAN Setup(LAN IP設定) (17)6.4.3 DNS(DNS設定) (17)6.4.4 VLAN(VLAN設定) (17)6.4.5 Status(網路狀態) (17)6.5SIP SETTING(SIP設定) (17)6.5.1 Service domain(服務平台) (18)6.5.2 Codec(語音編解碼) (18)6.5.3 RTP setting(RTP設定) (18)6.6NAT TRANSVERSA(NAT穿透設定) (18)6.7A DMINISTRATOR(管理設定) (18)七、網頁設定 (19)7.1I NFORMATION(系統資訊) (20)7.2P HONE S ETTING(IP CONF4設定) (20)7.2.1 Phone Book(電話簿) (20)7.2.2 Speed Dial(速撥) (21)7.2.3 Auto Answer(自動應答) (22)7.2.4 Dial plan setting(撥號規則設定) (23)7.2.5 Forward Setting(來電轉接設定) (24)7.2.6 Call Waiting(來電等待) (25)7.2.7 DND Setting(來電拒接設定) (25)7.2.8 Volume Setting(音量設定) (26)7.2.9 Melody Setting(鈴聲設定) (26)7.3N ETWORKING(網路設定) (27)7.3.1 Status(網路狀態) (27)7.3.2 Network Setting(網路設定) (28)7.3.3 DDNS Setting(DDNS設定) (29)7.3.4 VLAN Setting(VLAN設定) (29)7.3.5 SNTP Setting(時間侍伺器設定) (30)7.4NAT R OUTER(NAT路由器) (31)7.4.1 LAN Setting(LAN設定) (31)7.4.2 DMZ Setting(DMZ設定) (32)7.5SIP SETTING(SIP設定) (33)7.5.1 Service Domain(服務平台) (33)7.5.2 Port Setting(埠號設定) (34)7.5.3 Codec Setting(語音編解碼設定) (35)7.5.4 Codec ID (35)7.5.5 RTP Setting(RTP設定) (36)7.5.6 STUN Setting(STUN設定) (36)7.5.7 RPort Setting(RPort設定) (37)7.5.8 Other Setting(其他設定) (37)7.6O THERS(其他) (38)7.6.1 Auto Config(自動設定) (38)7.6.2 Firmware upgrade(韌體升級) (39)7.6.4 Default Setting(回復出廠設定) (41)7.6.5 FXO Port Setting(FXO埠設定) (41)7.6.6 ICMP Setting(ICMP設定) (42)7.6.6 System Auth(系統管理) (42)7.7S A VE C HANGE(儲存設定) (43)7.8R EBOOT(重新啟動) (43)八、常見問題及排除 (43)九、產品規格 (44)一、歡迎使用感謝您選擇ArtDio IP CONF4。

漏电保护设备的运用和保护

漏电保护设备的运用和保护

漏电保护设备的运用和保护为了能使漏电维护设备正常作业,坚持超卓的状况,然后起到维护效果,有必要做好以下几项运用和维护作业:(1)漏电维护设备投入作业后,运用单位应树立作业记载和相应的处理准则。

(2)漏电维护设备在新设备和作业一段时刻后,每月需在通电状况下,按动实验按钮,查看漏电维护设备是不是牢靠,雷旱时节应添加实验次数。

(3)巡视查看和守时查看修补时,应根除附在维护设备上面的尘土,以确保绝缘超卓。

(4)若漏电维护设备因被维护电路发作缺陷而分断电路时,要查明要素。

凡有白色漏电指示按钮的开关,应先查看一下该按钮。

若漏电方针按钮已跳起,阐明线路中已呈现漏电和触电缺陷,应查看要素并排出缺陷后才调将漏电指示按钮复位,再合开关。

若漏电指示按钮没跳起,则是过载缺陷。

(5)漏电维护设备在运用了必定次数后,在翻滚组织有些应加润滑油,确保操动组织动作活络、牢靠。

(6)漏电维护设备因被维护电路发作缺陷时,须翻开盖子进行内部收拾(首要收拾消弧室和触头),消弧室的内壁和栅片上要收拾洁净;要细心收拾触头上的毛刺、颗粒,确保触摸超卓。

当触头磨损到正本厚度的1/3时,要替换触头。

(7)为查验漏电维护设备在作业中的动作特性及改动,应守时进做法作特性实验。

首要内容有:查验漏电动作电流值;查验漏电不动作电流值;查验分断时刻。

(8)退出作业的漏电维护设备再次运用之前,要对其进做法作特性实验。

(9)守时剖析漏电维护器设备的作业状况,及时替换有缺陷的维护设备。

(十)漏电维护设备动作后,经查未发现事端要素时,容许试送电一次,假定再次动作,应查明要素找出缺陷,必要时对其进做法作特性实验,不得接连强行送电,除经查看供认维护设备自身发作缺陷外,阻挠私自撤消漏电维护设备强行送电。

(11)在漏电维护设备的维护计划内发作电击伤亡事端时,应查看漏电维护设备的动作状况,剖析未能起到维护的要素,在未查询前应维护好现场,不得拆动漏电维护设备。

Series BV3HL三件部分卫生漏流球阀指导书说明书

Series BV3HL三件部分卫生漏流球阀指导书说明书

SPECIFICATIONSService:Compatible liquids and gases.Body:3-piece.Line Size:1/2˝ to 4˝.End Connections:Tri-Clamp (liner meets BS 4825, part 3).Pressure Limits:1000 psi (69 bar) WOG. Wetted Materials:Body, Ball, End Caps: CF8M stainless steel.Stem: 316 stainless steel. Stem Seal: Fluoroelastomer.Seats, Body Seal, Thrust Washer, Packing: PTFE.Temperature Limits:-40 to 450°F (-40 to 232°C) CWP . 297°F (147°C) steam maximum.Other Materials:304 stainless steel, vinyl.INSTALLATIONGeneral Information for On-Site Installation - The valve may be fitted in any position in the pipeline. For automated operation, W.E.Anderson does recommend that the valve and actuator be installed vertically in case of valve leakage, although this is not necessary for proper operation of the valve. To prevent damage to the seats and ball surface, the pipeline must be flushed so that it is free of dirt, burrs and welding residues before installing the valve.Installation of Clamp End Valves -Use the proper clamp and O-ring for pressure range of application. Place the O-ring into the O-ring groove on the clamp end. Slide the valve between the clamp fittings while making sure that the O-ring remains in place. Install the clamp over both valve ends and clamp fitting to insure alignment. Tighten both clamps on each valve end. Check proper operation of valve (manually or with the actuator).The Series BV3HL Three-Piece Sanitary Ball Valve provideseasy replacement of gaskets, seals, and seats without any special tools. The swing-out design of the valve allows for the center section of the valve body to be replaced while leaving the ends clamped in place if necessary.The BV3HL uses a cavity filled design, which means that the ball can remain completely enclosed by the pure TFE seats, eliminating the chance of product entrapment. Combined with an investment cast 316L stainless steel casting, this series of valve is ideal for food, beverage, semi-conductor, or pharmaceutical applications.Superior leak protection is accomplished by using a live-loaded packing system featuring belleville washers. An ISO 5211mounting pad is provided for easy automation.OPERATIONManual Operation - To open or close the valve, turn the handle 90° (1/4 turn). Valve in OPEN position: the handle is parallel (in line)with the valve or pipeline. Valve in CLOSED position: the handle is perpendicular (crossed) with the valve or pipeline.Automated Operation -Valves with actuators should be checked for stem alignment. Most applications are direct mount to the actuator, greatly reducing any sideload or increased torque.Make sure that all insert adapters are properly placed on the valve stem and fully engaged in the actuator.©Copyright 2010 Dwyer Instruments, Inc.Printed in U.S.A. 2/10FR# R2-443348-00 Rev. 1Disassembling and Cleaning the Valve -CAUTION: Ball valves can trap fluids in the ball cavity when it is in the closed position. If the valve has been used with hazardous media, it must be decontaminated before disassembly or handling.WARNING:All persons involved in the removal or disassembly of the valve should wear protective gear such as eye and face protection, gloves, etc.Relieve the line pressure. Place the valve in the half-open position and flush the line to remove any hazardous material(s) from the valve.Replacing the Thrust Washer, Packing, and Seats -A repair kit is available for all valves comprising: seats, body seal, stem seal, thrust washer, and stem packing.NOTE:The Series BV3HL Sanitary Ball Valve is designed with belleville washers for automatic wear compensation. If there are signs of leakage from the stem, it is time to replace the stem packing and thrust washer.Before replacing the thrust washer, seats, and packing, the pipeline must be depressurized. Maintenance, removal and replacement of seats and seals is simple even if the valve is installed in line. By removing three of the body bolts and loosening the fourth bolt, the valve body can be swung out of line (see illustration 1.1). Seats, seals, gaskets and balls can be replaced without disturbing the pipe alignment.Bolt Tightening Specifications -The body bolts on the valve must be tightened evenly. Tighten the bolts by hand, then use a wrench to tighten bolts in diagonal opposition. See chart 1.2 for bolt torque specifications.WARRANTYThe Series BV3HL Sanitary Ball Valve is warranted from defects in materials and workmanship for (1) year from the date of purchase.In the unlikely event the valve should fail, the unit can be returned to the factory for warranty repair if the warranty period has not expired. Contact our customer service department for an RGA number and to set up the return.CHART 1.2: Bolt TorquesValve Size1/4˝3/8˝1/2˝3/4˝1˝1-1/2˝2˝2-1/2˝3˝Body Bolt Torque (IN LBS)4444536289186230336487ILLUSTRATION 1.1: Swing-out Design。

神奇小子 全能漏电保护插头

神奇小子 全能漏电保护插头
维普资讯
护顾 客忠诚 激活顾 客 多次 消费 的技术
手段 。
顾 客 忠 诚 营销成 为 家 电连 锁 业 营
销 管理 的主 要 手 段 必 将 引领 中国 家 电连
锁 业 的规 模经 济化健 康 发展 避 免 规 模
不 经 济和 社会 资源 的不 经 济重 复建设

一 的 厨 房卫 生 间污染控 制与环 境功能 存在环 境质量 差 污 染严 重 管线布置 、

改善技术研究
课题 即 日起在宁波正 ,
混 乱 设 备 之 间未形 成统~ 、
的模 数协 调
式启动 。
建设 部正 式 决定 由宁波方 太厨
等诸 多问题 此次 。

厨 房卫 生 间污染控
具 有限公 司 主 持该课题 的研 究 国 家建 。
制与环 境功能改善技术研 究 ”
课题 包 ,
设 部科技司张福麟处 长在会上 表示 : 由 括厨卫 功能设计与环境评价指标体系研

家企业 来承 担 国家重 大科研 项 目 表 ,
究 、
厨卫 污染控制与环 境产 品开 发 、

明 国家在构建 技术 创新体 系方面 的思 路 体厨 房 与 整体 卫 浴 环 境 改善集 成研 究 、
在发生转变 企业 技术创新的主体地位 ,
改善厨 卫 环 境 的技术标准研 究等 四 方 面
将得到逐 步加 强 。
主要 内容 。
课题 将通 过 一
系 列的科技攻

十~


国家科技支撑计划是 面
关 .
解决我 国现 行住 宅 中厨 房卫 生 问上
向国 民经 济和社会发展需 求 、
重点解决
述 问题 为 厨 房 卫 生 问更 加 健 康 环 保

科学物理学 3B 保护插头说明书

科学物理学 3B 保护插头说明书

3B SCIENTIFIC ® PHYSICS1Instructions d’utilisation08/22 HJB1 Borne de connexion : cathode 1 /2 Bornes de connexion : filament dechauffage3 / 5 Bornes de connexion : filament dechauffage4 Borne de connexion : cathodeL ’adaptateur de protection satisfait aux disposi-tions de sécurité pour les appareils électriques de mesure, de commande, de réglage et de labora-toire d'après la norme DIN EN 61010, 1ère partie. Il est prévu pour être exploité dans des pièces sèches convenant à des équipements élec-triques.En cas d'utilisation conforme, l'exploitation sûre de l'adaptateur est garantie. En revanche, la sé-curité n'est pas garantie si l'adaptateur n'est pas commandé dans les règles ou manipulé sans at-tention.S'il s'avère qu'une exploitation peu sûre n'est plus possible (par ex. en présence de dommages ap-parents), mettez l'adaptateur immédiatement hors service.∙ Ne pas exposer l’adaptateur à une humiditétrop élevée, à des températures extrêmes ouà de fortes vibrations. ∙ Pour les connexions, utilisez uniquement descâbles d'expérimentation de sécurité.L’adaptateur de protection bipolaire ou tripolaire sert, pour les triodes D, de connexion entre la tension de chauffage et les cordons de sécurité, et sert également de disjoncteur protégeant le chauffage du la cathode contre les surtensions, ce qui évite de détériorer le filament très sensible. Le relais intégré se coupe lorsque des tensions de chauffage d’env. 10,5 V DC et env. 8,5 V AC sont atteintes, et se remet en marche lorsque la tension de chauffage est baissée.La broche de raccordement portant le symbole Moins, est reliée au connecteur marron.Sur l’adaptateur de protection tripolaire, le connec-teur rouge est équipé d’une broche de connexion de 2 mm.Le choix de l’adaptateur bipolaire ou tripolaire dé-pend du tube utilisé (Les tubes adaptés sont lis-tés sous le point 4).3B Scientific GmbH ▪ Ludwig-Erhard-Str. 20 ▪ 20459 Hambourg ▪ Allemagne ▪ Sous réserve de modifications techniques © Copyright 2022 3B Scientific GmbHConnexions : bornes de sécurité de 4 mm Tension de coupure : CC : env. 10,5 V CA : env. 8,5 V Dimensions : env. 75 mm x 45 mm Ø Masse : env. 70 gLes adaptateurs de protection sont prévus pour les tubes suivants :bipolaire (1009961) : Diode D 1000646 Triode D 1000647 Tube luminescent D 1000648 Tube à croix de Malte D 1000649 Tube de Perrin D 1000650 Tube à déviation D 1000651 Triode à gaz D 1000653tripolaire (1009960) : Tube à diffraction D 1013885∙ Connecter l’adaptateur sur le connecteur dutube utilisé de sorte que la broche de con-nexion portant de l’adaptateur portant le sym-bole Moins (broche marron) soit connectée à la broche de connexion du tube portant le symbole Moins. ∙ Insérer le tube dans le support de tubes D,brancher et mettre en marche.∙ Débrancher l'adaptateur avant le nettoyage. ∙Utiliser un chiffon doux et humide.∙L'emballage doit être dé-posé aux centres de re-cyclage locaux.∙ Si l'adaptateur doit être jeté, ne pas le jeter dans les ordures ménagères. Il est important de res-pecter les consignes lo-cales relatives au traite-ment des déchets élec-triques.。

漏电保护插头使用方法

漏电保护插头使用方法

漏电保护插头使用方法
漏电保护插头是一种非常重要的家用电器,它能够在电器发生漏电时迅速切断电源,保护人身安全。

正确使用漏电保护插头对于家庭用电安全至关重要。

下面就是漏电保护插头的使用方法。

首先,选择合适的漏电保护插头。

在购买漏电保护插头时,一定要选择正规渠道购买,确保产品质量和安全性。

另外,要根据家庭用电情况选择合适的额定电流和额定电压的漏电保护插头,以确保其正常使用和保护功能。

接下来,正确插拔漏电保护插头。

在使用漏电保护插头时,要注意正确插拔,确保插头插入插座时稳固牢固,不要晃动。

在拔出插头时,要轻力拔出,不要用力过大,以免损坏插头或插座。

另外,定期检查漏电保护插头的使用情况。

漏电保护插头也需要定期检查,确保其正常使用。

在使用过程中,要留意观察插头表面是否有损坏或者老化现象,及时更换损坏的插头,以免影响其保护功能。

此外,正确使用漏电保护插头。

在使用过程中,要按照说明书上的使用方法正确使用漏电保护插头,不要私自拆卸或者改装插头,以免影响其使用效果。

另外,要避免长时间使用过载电器,以免损坏漏电保护插头。

最后,保持漏电保护插头的清洁和干燥。

定期清洁插头表面的灰尘和污垢,并保持插头的干燥,以确保其正常使用和保护功能。

总之,漏电保护插头是家庭用电安全的重要保障,正确使用漏电保护插头对于家庭用电安全至关重要。

希望大家能够严格按照上述使用方法正确使用漏电保护插头,确保家庭用电安全。

漏电保护装置的使用和维护(三篇)

漏电保护装置的使用和维护(三篇)

漏电保护装置的使用和维护漏电保护装置(也叫做漏电保护器)是一种用于监测和保护电路的设备,它能够检测到电流泄漏,一旦发现电流泄漏超过了设定值,就会迅速切断电路,以保护人身安全和电气设备的安全。

漏电保护装置的使用和维护非常重要,下面将从几个方面介绍它们的使用和维护要点。

首先,需要选择合适的漏电保护装置。

在选择漏电保护装置时,应根据电路的额定电流和额定电压来确定保护装置的额定电流和额定断电时间。

此外,还应考虑电路环境和使用要求,选择适当的保护装置类型,如固定式或便携式的。

其次,漏电保护装置需要正确安装和接线。

根据装置的说明书,正确安装和接线是确保漏电保护装置正常工作的关键。

在安装过程中,需要确保保护装置的工作电流不小于接线及负载电流之和,并连接到适当的电气系统中。

第三,漏电保护装置要定期进行检测和测试。

漏电保护装置的测试包括静态测试和工作测试。

静态测试包括使用专业测试仪器,测试保护装置的电气参数是否符合规定。

工作测试则需模拟实际使用情况,触发装置以确保其能正确切断电路。

这些测试应由专业人员进行,并记录测试结果,以确保装置的可靠性和稳定性。

此外,还要定期对漏电保护装置进行维护。

维护包括清洁保护装置和检查连接螺钉是否松动,以确保装置正常工作。

如发现漏电保护装置有异常情况,如漏电报警、无法重置等,应立即停止使用并联系专业维修人员进行处理。

对于长时间不使用的漏电保护装置,应定期进行激活测试,确保其正常工作。

如果长时间没有进行激活测试,保护装置可能会因内部元件老化而失去保护功能。

最后,需要定期对漏电保护装置进行更换。

根据使用年限和使用环境的不同,漏电保护装置的使用寿命会有所差异。

一般来说,固定式装置的使用寿命为5到10年,便携式装置的使用寿命为3到5年。

如果保护装置超出了使用寿命,就需要更换为新的装置。

总之,漏电保护装置的使用和维护对于确保电路安全和保护人身安全非常重要。

正确选择、安装、测试、维护和更换漏电保护装置,能够减少电气事故的发生,保护电气设备和人员的安全。

LBX-III全能漏电保护插头使用及维修指引(第四版)

LBX-III全能漏电保护插头使用及维修指引(第四版)

LBX-10(16)-Ⅲ全能漏电保护插头使用及检修指引(第四版)——供售后人员培训专用教材一、全能漏电保护器的简单介绍1.漏电保护器的触电保护由于漏电保护器是电流型的保护器,每只保护器都有它的漏电动作电流值,只有当漏电电流达到该动作值时,漏电保护器才会切断电源,而且随着漏电电流的增大,切断电源的动作时间会迅速减少。

标准规定当漏电流达到0.25A或5I△n时,动作时间必须少于0.04秒,从而确保人身安全。

当使用时,如果有良好的接地,热水器的外壳永远都是接近零电位(<5V),无论漏电多大,人身触及都不会有感觉。

当漏电流≥其动作值时即切断电源,且末排除故障前是不可能复位通电(即使按住复位键也不能通电)。

若用户没有接地措施,由于没有漏电电流的回路,因此,即使发生多大的“漏电”故障,漏电保护器是不会断电的,电热水器外壳带有220V的空载电压。

当人触及故障的热水器,漏电流就会经人体泄向大地,只要该电流≥动作电流,漏电开关立即断电。

这就是通常所说的先触电后保护,不会造成人身伤亡事故(当然应尽量要求用户电源系统接地为宜)。

III型全能漏电保护插头是一种全方位解决所有与电有关的事故的用电安全保障产品,它在电热水器漏电,接地系统异常(地线意外带电)的情况下均能提供有效的保护,除此之外,它还带有插头温度保护功能,当插座不良导致插头、插座产生异常温升时提供保护,当插头温升过高时自动断电,有效的扼制了插头、插座烧烂造成短路,电气火灾事故的发生,因此无论发生什么样的故障,它都能及时断电,故障越大,断电速度越快,而且断电效果和拔出插头效果是相同的,在插头内部与电源彻底分离。

2.关于电热水器标准附录AA现实中电热水器有不少事故是在它本身无故障情况下发生的,虽然这些事故不是电热水器本身所导致,但毕竟也是因为使用了电热水器后才会发生的,而且这类事故往往比热水器本身故障而引发的事故更为严重。

实际上这类事故都是从电源的地线(黄绿保护线)引入的,为了确保使用者安全,电热水器标准就相应增加了在接地系统异常情况下能提供保护措施的附录AA。

漏电保护器安全系统使用问答

漏电保护器安全系统使用问答

漏电保护器安全使用问答弱电学院---文章分类: 电工→电气技术∧上一篇∨下一篇◎最新发布列表...双击自动滚屏发布者:弱电网发布时间:2009-8-29 22:09:00 来源:互联网总阅读:298次本周阅读:5次今日阅读:4次一、漏电保护器的作用1.什么是漏电保护器?答:漏电保护器(漏电保护开关)是一种电气安全装置。

将漏电保护器安装在低压电路中,当发生漏电和触电时,且达到保护器所限定的动作电流值时,就立即在限定的时间内动作自动断开电源进行保护。

2.漏电保护器的结构组成是什么?答:漏电保护器主要由三部分组成:检测元件、中间放大环节、操作执行机构。

①检测元件。

由零序互感器组成,检测漏电电流,并发出信号。

②放大环节。

将微弱的漏电信号放大,按装置不同(放大部件可采用机械装置或电子装置),构成电磁式保护器相电子式保护器。

③执行机构。

收到信号后,主开关由闭合位置转换到断开位置,从而切断电源,是被保护电路脱离电网的跳闸部件。

3.漏电保护器的工作原理是什么?答:①当电气设备发生漏电时,出现两种异常现象:一是,三相电流的平衡遭到破坏,出现零序电流;二是,正常时不带电的金属外壳出现对地电压(正常时,金属外壳与大地均为零电位)。

②零序电流互感器的作用漏电保护器通过电流互感器检测取得异常讯号,经过中间机构转换传递,使执行机构动作,通过开关装置断开电源。

电流互感器的结构与变压器类似,是由两个互相绝缘绕在同一铁心上的线圈组成。

当一次线圈有剩余电流时,二次线圈就会感应出电流。

③漏电保护器工作原理将漏电保护器安装在线路中,一次线圈与电网的线路相连接,二次线圈与漏电保护器中的脱扣器连接。

当用电设备正常运行时,线路中电流呈平衡状态,互感器中电流矢量之和为零(电流是有方向的矢量,如按流出的方向为“+”,返回方向为“-”,在互感器中往返的电流大小相等,方向相反,正负相互抵销)。

由于一次线圈中没有剩余电流,所以不会感应二次线圈,漏电保护器的开关装置处于闭合状态运行。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

LBX-10(16)-Ⅲ全能漏电保护插头使用及检修指引(第四版)——供售后人员培训专用教材一、全能漏电保护器的简单介绍1.漏电保护器的触电保护由于漏电保护器是电流型的保护器,每只保护器都有它的漏电动作电流值,只有当漏电电流达到该动作值时,漏电保护器才会切断电源,而且随着漏电电流的增大,切断电源的动作时间会迅速减少。

标准规定当漏电流达到0.25A或5I△n时,动作时间必须少于0.04秒,从而确保人身安全。

当使用时,如果有良好的接地,热水器的外壳永远都是接近零电位(<5V),无论漏电多大,人身触及都不会有感觉。

当漏电流≥其动作值时即切断电源,且末排除故障前是不可能复位通电(即使按住复位键也不能通电)。

若用户没有接地措施,由于没有漏电电流的回路,因此,即使发生多大的“漏电”故障,漏电保护器是不会断电的,电热水器外壳带有220V的空载电压。

当人触及故障的热水器,漏电流就会经人体泄向大地,只要该电流≥动作电流,漏电开关立即断电。

这就是通常所说的先触电后保护,不会造成人身伤亡事故(当然应尽量要求用户电源系统接地为宜)。

III型全能漏电保护插头是一种全方位解决所有与电有关的事故的用电安全保障产品,它在电热水器漏电,接地系统异常(地线意外带电)的情况下均能提供有效的保护,除此之外,它还带有插头温度保护功能,当插座不良导致插头、插座产生异常温升时提供保护,当插头温升过高时自动断电,有效的扼制了插头、插座烧烂造成短路,电气火灾事故的发生,因此无论发生什么样的故障,它都能及时断电,故障越大,断电速度越快,而且断电效果和拔出插头效果是相同的,在插头内部与电源彻底分离。

2.关于电热水器标准附录AA现实中电热水器有不少事故是在它本身无故障情况下发生的,虽然这些事故不是电热水器本身所导致,但毕竟也是因为使用了电热水器后才会发生的,而且这类事故往往比热水器本身故障而引发的事故更为严重。

实际上这类事故都是从电源的地线(黄绿保护线)引入的,为了确保使用者安全,电热水器标准就相应增加了在接地系统异常情况下能提供保护措施的附录AA。

附录AA实际上是包括两个内容:一、把发热管绝缘完全破坏来模拟电热水器故障;二、把220V相极电压直接加到内胆上来模拟接地系统异常,在这两种情况下分别检测电热水器的出口管可触及的金属部位(或与内胆相连的金属部件)和距离出水口1公分处流出来的水对地的漏电流,要求漏电流不得大于5mA(稳态值)。

从而保障电热水器和电热水器的接地系统在异常情况下均不会给使用者带来伤害。

二.全能漏保配套在电热水器上安装时应注意的事项1.安装前应先检查用于电热水器的电源插座。

GB20429-2006《电热水器安装规范》5.3.3 明确规定:热水器的电源插座必须使用单独的固定插座,插座结构要与待装热水器的插头匹配。

a.规格应与插头相对应,10A插头应用10A插座,16A插头应用16A插座。

因为电热水器功率大通电时间长,所以每台机必须独立配置优质插座,插座应牢牢固定墙上,距离地面在1.6米以上,淋浴时水不会喷到的位置,切勿使用多位移动式插座排,能插各式各样插头的万用型插座绝对不可以用在电热水器上。

b.插座质量必须良好,劣质插座会因接触不良发热、打火而损坏插头(插头内的电子零件长时间处于高温下会损坏,而打火会产生很高的瞬间电压,窜入电源把电子零件打坏),插头插至插座后不可有松动的感觉。

c.检查插座各极接线是否正确。

正确的接线应为地线在上、相线在右边、零线在左边(图一),可采用我公司生产的电源检测仪(相位仪)方便地对插座内接线状况作出判断,对安装不规范的能立即显示出错误的原因,以便及时作出整改。

符合正确接线指示的插座才是安全的电源。

d.应采用不带开关的插座,因为当开关关断后全能漏保就不处于工作状态,一旦出现地线带电就无法提供保护!应为220V左右 L N为220VN 应为0(或(图一)2.完成插座检查后,就可以进行电热水器安装,安装后要先进行通水,通水的方法是同时打开进、出口水管,一边进水一边排空气,直到出水口有水流出才算灌满内胆,之后再插上插头,同时对插头进行动作试验,方法是按下“复位”——通电(指示灯亮),再按“试验”——断电(指示灯灭),然后就可以按复位通电投入正常使用,并告诉用户仔细阅读插头上的说明贴纸所列的注意事项。

3.应叮嘱用户在使用时经常进行试验,至少要一周试跳一次,确保漏电保护器在正常状态下运转。

如有故障应立即停止使用,且通知维修站检修,用户千万不要擅自拆卸,叮嘱用户千万不可把漏电保护插头掉到水中。

建议用户使用后无需把插头拔出来,经常插拔很容易损坏插座,还会把插头摔坏。

这款插头断电(指示灯熄灭)时,在插头内部与电源是完全分离的,只有按下复位才会与电源连接。

只要不是连续按动试验——复位操作(每分钟操作次数不大于2次),可以通过“试验”键和按“复位”键进行断电、通电的操作。

4.维修电热水器时必须把插头拔出后再进行。

5.插头本身耗电极微,长期通电可保持插头内部干燥和电子元器件的正常工作状态,徜若断电时间比较长,重新使用时,必须进行试验操作。

6.电热水器进出水口与机外管网(例如:自来水管等)连接应采用全塑料管(PP-R管或神奇小子)进行连接。

7. 电热水器安装挂架(钩)上的紧固螺丝应外套塑料套,最好是在热水器安装挂架与热水器之间或热水器挂架与墙体之间加装好绝缘垫,这样既可以避免安装螺丝碰到建筑物的钢筋形成短路,又可避免当墙体潮湿时安装挂架或爆炸螺丝对墙体形成对地通路而造成误动作。

三.售后检修的现场检查方案和程序1.检查插座是否万用插座、劣质插座、与插头的规格是否匹配,是否异常发热。

2.用电源检测仪(相位仪)检查电源插座内部接线是否正常。

检查地线是否异常。

3.检查漏保插头是否正常工作、铜插脚是否变形损坏、插头插座是否异常发热。

判断漏保是否正常可只把线尾拆下、不与热水器连接,然后按下复位按钮应能正常接通电源,指示灯应点亮,再按下试验按钮漏保应即刻跳闸断电,指示灯熄灭为正常。

4. 根据用户的反映重复进行试验、分析判断。

5.检查热水器各部件是否存在绝缘破损、发生漏电故障或接线错误。

因为漏保是热水器的供电源头,加热管绝缘不良、高温极限、温控器等漏电故障均会造成漏保跳闸。

6.检查测量热水器进出水口对自来水管间的电阻应大于10KΩ(连接状态,安装神奇小子),如果与自来水管连接处于断开状态(拆开)时电阻值应是无穷大,用以判断两者之间是否采用了有效的全塑料管连接。

7.检查测量热水器外露金属部件(包括内胆)对电源插座地极孔之间的电阻,或测量热水器外露金属部件对自来水金属管或燃气金属管道等之间的电阻要应较大,一般都应大于100KΩ以上(测量时把插头拔下,把进出水口水管拆下),用以判断热水器安装是否触及钢筋等物体,同时检查观察墙体是否潮湿。

8.询问用户和观察漏保,看是否曾因使用不当,进过水造成漏保故障。

通过以上相关的程序检查、测量来做出判断,尽量避免造成误判。

四、售后检修时遇到漏保“误跳”的原因分析及解决方法:1、插座不良造成插头插座接触不良发热温升过高造成跳闸断电。

通常通电一段时间后(约半小时到一小时)自动断电,复位后能通电,但过一段时间后又自动断开,这种情况是由于温度保护发挥作用所导致的,只要留心观察,会发觉在即将断电或刚断电时插头会是滚烫的,温度比较高,这时是无法复位的,只有在插头冷却后才可以重新复位通电。

出现这种情况大多数是由于插座不良或用户拔插插头过于频繁,令插座插套疲劳所导致,通常更换优质插座后就可以解决,同时告诫用户切勿经常插拔插头,拔插过频容易导致接触不良发热,还有就是用户不小心把插脚弄变形,同样也会导致接触不良,这时可以小心地把插脚进行校正,令三只插脚(特别是左、右脚)务必保持平直,与底面垂直互成60度角,插头与插座之间的配合应当比较紧,不能有松动的感觉,如果觉得松动,那就是插座内簧片疲劳需要更换插座了。

同时千万不可以用万用插座,这类型插座的插脚和插座插套的接触面只是一条线,通电流的面积小了很多,而且长期拔插还会对铜插脚造成损坏(中间插出一条槽)。

解决办法:更换为单独的固定式优质插座。

2、热水器进出水口与自来水管之间是采用含金属的管道连接的;或热水器挂钩螺丝碰到墙体钢筋、以及热水器安装墙体潮湿均会全能漏保误动作。

售后全能漏保误动作的一般都是这个原因造成的。

这种情况是因为用户的电源是接零保护系统,同时热水器与自来水管连接又采用了金属管或铝塑复合管、带金属蛇皮的软管等,或热水器安装架挂钩螺丝接触到建筑物钢筋,或安装墙体潮湿,在这种情况下接零保护系统就变为混合保护系统,电流从相线流入经过热水器再流回零极时,会在零、地的连接点经电源线黄绿线→热水器内胆→进出水口水管(挂钩螺丝)→自来水管(建筑物钢筋)而分流走一部分(图二)。

这种情况相当于接零、接地混合系统,由于全能漏电保护插头在地线带电时也会断电,因此,遇到这种情况漏保插头就会发生跳闸断电了。

解决办法:要解决这个问题有两个办法,具体如下:1)、第一种办法:把接零保护改为接地保护(图三),但插座的电源系统是用户的,我们轻易不能,也无法去变更。

挂钩螺丝建筑物钢筋2)、第二种办法:在热水器进、出水口与自来水管之间加一对全塑料管接接头(神奇小子)或采用全塑料PP-R管连接,以及在热水器安装挂钩的螺丝上外套塑料套或在挂架上做好与墙体的绝缘,再安装在墙上,从而切断了经自来水管对地,以及经安装挂架对建筑物钢筋(墙体)的通路,从而避免发生误动作。

3、由于热水器零部件绝缘不良,例如:加热管绝缘破坏、温控器或高温极限坏或漏电,原因未查明就更换漏保造成误判。

解决办法:用兆欧绝缘电阻摇表和万用表检查测量热水器上的各零部件是否属于正常,查清原因后,把相应的故障零件给予更换。

4、漏保是否已损坏造成跳闸的检查判断:把漏保线尾拆下不与热水器连接,测试检查漏保,如果拆下线尾后漏保可以正常复位通电,指示灯点亮,按试验正常断电的则漏保是好的,这时就应仔细检查热水器及热水器安装(包括墙体是否潮湿)是否存在问题;如果拆下线尾后,漏保仍然是无法按下复位通电的,或按试验不跳闸断电是漏保已坏故障,不可再用,需更换处理。

5、用户使用不当,造成漏保进过水,造成误跳或进水短路烧坏漏保机内零件。

漏保插头虽然增加了防水罩,防护等级可达IP53,但是它只能对正面短时间的喷淋起到防护作用,一旦用户不小心把插头掉到水中,就很容易进水。

这时徜若插回插座通电就会造成内部短路损坏插头,通常掉进水,那怕时间再短都会进水的,而且进了水之后就很难干的,为了避免用户把插头掉到水中,最好投入使用后就不要再拔出插头(要断电可按试验键),非要拔插头时可利用插头下的挂钩挂在墙上或者通过挂钩旁的叉卡在电线上(16A 有这个叉,10A没有),防止掉到水中。

相关文档
最新文档