光纤交换机配置(命令)
光纤交换机篇
Updating flash ...
test:admin> cfgenable "cfg"使cfg配置生效
0x10280c00 (tShell): Jan 5 23:45:22
WARNING ZONE-SOFTZONING, 3, WARNING - port 2: zoning enforcement changed to SOFT
Updating flash ...
test:admin> zoneshow查看配置情况
Defined configuration:所有配置
cfg: cfg zone; wwn
cfg: cfg2 zone2
cfg: cfg3 zone3
zone: wwn 20:0c:00:a0:b8:17:67:e2; 10:00:00:00:c9:3a:ad:2e
aliadd "array1", "1,2"
aliremove "array1", "1,2"
alidelete "array1"
三、总结
1、
wwn号zone可以跨越portzone。
zone外端口和zone内端口无法连接
2、命令规律
创建zone、别名、cfg分别是
Zonecreate、alicreate、cfgcreate
配置过程:
test:admin> alicreate "ali","1,1;1,2"创建别名ali,包括端口1,1;1,2
test:admin> zonecreate "zone","ali"创建zone,包含别名ali
(完整版)博科光纤交换机基本配置
博科 300光交换配置手册1.设备示意图2.配置准备Brocade交换机采用B/S架构,远程客户端通过交换机以太网管理端口实现对交换机的监控及配置。
在配置之前首先要在客户端安装JAVA运行环境JRE。
3.设备配置修改客户端IP地址与交换机为同一子网10.77.77.100;打开浏览器输入http://10.77.77.77按下回车后会弹出登陆对话框;户名:admin 密码:password备注:admin: 可以执行所有的命令并查看交换机状态和修改交换机的配置user: 执行Show命令来查看交换机的状态•改变密码以admin身份执行passwd命令会显示每个用户,可以依次修改他们的密码4.常用配置命令1)Tip: 可使用下面的命令来检查Fabric OS的版本sw:admin> version Kernel: 5.3.1 Fabric OS: v3.0.2cMade on: Thu Apr 19 12:02:15 PDT 2002 Flash: Thu Apr 19 12:04:03 PDT 2002 BootProm: T ue Apr 26 18:33:23 PST 20022)ipAddrShow –显示交换机的IP设置sw:admin> ipAddrShowEthernet IP Address: 10.77.77.77 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: none Fibre Channel Subnetmask: none Gateway Address: 0.0.0.0 • ipAddrSet3)为交换机设置IP地址sw:admin> ipAddrSetEthernet IP Address [10.77.77.77]: 192.168.66.107 Ethernet Subnetmask [0.0.0.0]: 255.255.255.0 Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Gateway Address [172.17.1.1]:Set IP address now? [y = set now, n = next reboot]: y • sw2:4)显示交换机配置admin> switchShowswitchName: sw2 switchType: 9.1 switchState: Online switchMode: Native switchRole: Subordinate switchDomain: 97 switchId: fffc61switchWwn: 10:00:00:60:69:04:23:03 switchBeacon: OFFport 0: id 2G No_Light port 1: id 2G No_Light port 2: id 2G No_Light port 3: id 2G No_Lightport 4: id 2G Online F-Port 10:00:00:00:c9:20:d0:99 port 5: id 2G No_Lightport 6: id N2 Online E-Port 10:00:00:60:69:50:3e:1b “sw2” (downstream)port 7: id 1G Online L-Port 8 Private, 2 phantom port 8: id 1G No_Light port 9: id N2 No_Light port 10: id 2G No_Lightport 11: id N1 Online port 12: id 2G No_Lightport 13: id 2G Online E-Port 10:00:00:60:69:50:02:73 “sw8" (upstream) (Trunk master)port 14: id N2 No_Light5)显示交换机运行状态admin> switchstatusshowSwitch Health Report Report time: 06/22/2015 07:53:50 AMSwitch Name: adminIP address: 192.168.99.9SwitchState: HEALTHYDuration: 00:05Power supplies monitor HEALTHYTemperatures monitor HEALTHYFans monitor HEALTHYFlash monitor HEALTHYMarginal ports monitor HEALTHYFaulty ports monitor HEALTHYMissing SFPs monitor HEALTHYFabric Watch is not licensedDetailed port information is not included6)显示交换机配置信息admin> cfgshowDefined configuration:cfg: cfg_1 a750l1_vtl12; b750l1_v7000; b750l2_v7000; b750l2_vtl12; ha1;vm1l_v7000; vm2l_v7000; vm3l_v7000; vtape; xenserver_a;xenserver_bzone: a750l1_vtl121,2; 1,20; 1,21; 1,22; 1,23zone: b750l1_v70001,0; 1,1; 1,2zone: b750l2_v70001,0; 1,1; 1,3zone: b750l2_vtl121,3; 1,20; 1,21; 1,22; 1,23zone: ha1 1,2; 1,3zone: vm1l_v70001,0; 1,1; 1,4zone: vm2l_v70001,0; 1,1; 1,5zone: vm3l_v70001,0; 1,1; 1,6zone: vtape 1,20; 1,21; 1,22; 1,23zone: xenserver_a1,0; 1,1; 1,8zone: xenserver_b1,0; 1,1; 1,77)备份交换机配置admin> configuplocadadmin> Protocol (scp or ftp):ftp (输入协议,如果你是FTP就输入FTP)admin> host: (FTP服务器地址:192.168.99.100)admin> user name: (用户名)admin> filename: 备份文件名称admin> password: 密码8)已有备份文件还原admin> switchdisable 停用交换机所有交换端口admin>configdownloadadmin>Protocol (scp or ftp):ftpadmin>Server Name or IP Address [host]:admin>User Name [user]:admin>File Name [config.txt]:config.txt.........admin>Do you want to continue [y/n]:yadmin>Password:admin>reboot9)划分zone定义:zone是当你有不同平台的主机连到SAN上时,用来隔离不同主机对磁盘阵列的存取,严格一点的,任何一台主机连到交换机访问任何一个存储设备都要作zone。
C 系列光纤交换机 - Cisco MDS san switch 中常用的命令
C 系列光纤交换机- Cisco MDS san switch 中常用的命令1. 通过以下命令可以查看接口信息:Cisco9124e# show interface brief-------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper PortMode Trunk Mode Speed ChannelMode (Gbps)------------------------------------------------------------------------------- bay1 2 auto on up -- F 4 -- bay2 1 auto on extDisabled -- -- -- bay3 1 auto on down -- -- -- bay4 1 auto on extDisabled -- -- -- bay5 1 auto on extDisabled -- -- -- bay6 1 auto on extDisabled -- -- -- bay7 1 auto on extDisabled -- -- -- bay8 1 auto on extDisabled -- -- -- bay9 1 auto on extDisabled -- -- -- bay10 1 auto on extDisabled -- -- -- bay11 1 auto on down -- -- -- bay12 1 auto on extDisabled -- -- -- bay13 1 auto on extDisabled -- -- -- bay14 1 auto on extDisabled -- -- -- bay15 1 auto on extDisabled -- -- -- bay16 1 auto on extDisabled -- -- ---------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper PortMode Trunk Mode Speed ChannelMode (Gbps)------------------------------------------------------------------------------ ext1 2 auto on up swl FL 4 -- ext2 2 auto on up swl FL 4 -- ext3 1 auto on sfpAbsent -- -- -- ext4 1 auto on sfpAbsent -- -- -- ext5 1 auto on sfpAbsent -- -- -- ext6 1 auto on sfpAbsent -- -- -- ext7 1 auto on sfpAbsent -- -- -- ext8 1 auto on sfpAbsent -- -- --------------------------------------------------------------------------------- Interface Status Speed(Gbps)------------------------------------------------------------------------------- sup-fc0 up 1 ------------------------------------------------------------------------------- Interface Status IP Address Speed MTU------------------------------------------------------------------------------- mgmt0 up 16.157.125.51/22 100 Mbps 15002. 查看VSAN的情况:Cisco9124e# show fcdomain domain-listVSAN 1 Number of domains: 1Domain ID WWN--------- -----------------------0x64(100) 20:01:00:0d:ec:80:f6:c1 [Local] [Principal]VSAN 2 Number of domains: 1Domain ID WWN--------- -----------------------0x11(17) 20:02:00:0d:ec:80:f6:c1 [Local] [Principal]3. 查看zone的配置:Cisco9124e# show zone status vsan 1VSAN: 1 default-zone: deny distribute: active only Interop: default mode: basic merge-control: allowsession: nonehard-zoning: enabled broadcast: unsupportedDefault zone:qos: none broadcast: unsupported ronly: disabledFull Zoning Database :DB size: 4 bytesZonesets:0 Zones:0 Aliases: 0Active Zoning Database :Database Not AvailableStatus:Cisco9124e# show zone status vsan 2VSAN: 2 default-zone: permit distribute: active only Interop: default mode: basic merge-control: allowsession: nonehard-zoning: enabled broadcast: unsupportedDefault zone:qos: none broadcast: unsupported ronly: disabledFull Zoning Database :DB size: 4 bytesZonesets:0 Zones:0 Aliases: 0Active Zoning Database :Database Not Available Status:4. 配置zone:Cisco9124e# conf tEnter configuration commands, one per line. End with CNTL/Z. Cisco9124e(config)# zone name zone2 vsan 2Cisco9124e(config-zone)# member fwwn 20:10:00:0d:ec:80:f6:c0 Cisco9124e(config-zone)# member fwwn 20:0a:00:0d:ec:80:f6:c0 Cisco9124e(config-zone)# member fwwn 20:0e:00:0d:ec:80:f6:c0 Cisco9124e(config-zone)# exitCisco9124e(config)# zoneset name zoneset2 vsan 2Cisco9124e(config-zoneset)# member zone2Cisco9124e(config-zoneset)# exitCisco9124e(config)# zoneset activate name zoneset2 vsan 2 Zoneset activation initiated. check zone statusCisco9124e(config)# exitCisco9124e# show zoneset activezoneset name zoneset2 vsan 2zone name zone2 vsan 2* fcid 0x110200 [fwwn 20:10:00:0d:ec:80:f6:c0]* fcid 0x1100ef [fwwn 20:0a:00:0d:ec:80:f6:c0]* fcid 0x1101ef [fwwn 20:0e:00:0d:ec:80:f6:c0]zone name $default_zone$ vsan 2Cisco9124e#。
博科_光纤交换机配置命令一览
DS_200B:admin> helpaaaconfig Configure RADIUS for AAA servicesad Specifies all administration domain (AD)-leveloperationsag Configure the Access Gateway featureagshow Displays the Access Gateway information registered with the fabricagtcfgdefault Reset SNMP agent to factory defaultaliadd Add a member to a zone aliasalicreate Create a zone aliasalidelete Delete a zone aliasaliremove Remove a member from a zone aliasalishow Print zone alias informationaptpolicy Get and set Advanced Performance Tuning policy auditcfg Modifies and displays audit log filterconfiguration.authutil Get and set authentication configuration backplanetest Backplane connection test for multi-blade systems. backport Test for back-end ASIC pair to ASIC pair links. bannerset Set security bannerbannershow Display security bannerbcastshow Display broadcast routing informationbladebeacon Enables or disables blade beaconing or displays the current mode.bladedisable Disables all user ports on a blade.bladeenable Enables all User Ports on a blade.burninerrclear Clear errors that are stored in the non-volatilestorageburninerrshow Display errors that are stored in the non-volatilestorageburninstatus Display the diagnostics burnin status.camtest Verify QuickLoop's Content Addressable Memory(CAM).SID translationcentralmemorytest Test ASIC central memory operation. cfgactvshow Display Effective zone configuration information cfgadd Add a member to a configurationcfgclear Clear all zone configurationscfgcreate Create a zone configurationcfgdelete Delete a zone configurationcfgdisable Disable a zone configurationcfgenable Enable a zone configurationcfgremove Remove a member from a configurationcfgsave Save zone configurations in flashcfgshow Print zone configuration informationcfgsize Print size details of zone databasecfgtransabort Abort zone configuration transactioncfgtransshow Print zone configurations in transaction buffer chassisconfig Display or set the chassis configuration chassisname Display or set the chassis's Namechassisshow Display all Field Replaceable Units (FRU) chipregshow Displays the port registers for a given chipnumber.cmemretentiontest Data retention test of the central memory SRAMs. cmitest Verify CMI bus between ASICs.configdefault Reset config to factory defaultconfigdownload Load switch config from a serverconfigshow Print switch config parametersconfigupload Save switch config to a serverconfigure Set switch config parametersdatatypeshow Display available diagnostic data types.date Print/set the system date and timedbgshow Display debug levels of various modulesdefzone Activates or deactivates a default zoneconfiguration.diagclearerror Clears diagnostics failure status. diagcommandshow Display diagnostic command descriptions. diagdisablepost Disable diagnostic POST.diagenablepost Enable diagnostic POST.diagenv Diagnostic debug parameters management package. diaghelp Display diagnostic command descriptions. diagloopid Select the diagnostics loop ID.diagmodeshow Displays diagnostic mode configuration. diagpost Displays the contents of port registers andmemories.diagretry Sets diagnostic retry modediagsetburnin Initializes the blade for a burnin run.diagsetcycle Set diagnostic script parameters.diagsetesdmode Set or display ESD mode.diagsetshowtime Set or display diagnostic show-time mode. diagshow Display diagnostic status.diagshowtime Set or display diagnostic show-time mode. diagstatus Display currently running diagnostic tests. diagstopburnin Terminate burnin run on a blade.distribute Distributes data to switches in a fabric.dlsreset Turn off the dynamic load sharing (DLS) optiondlsset Turn on the dynamic load sharing (DLS) option dlsshow Display the state of the dynamic load sharingoptiondnsconfig Configure DNS serviceenclosureshow Display the switch enclosure attributes errclear Clear error logerrdelimiterset Sets the error log start and end delimiter formessages sent to the console and syslogerrdump Print error log (no page breaks)errfilterset Sets a filter for an error log destination errmoduleshow Displays all the defined modules in the system errshow Print error logfabportshow Display contents of a particular port's data fabretryshow Display retry count of various fabric commands fabriclog Displays or manipulates the fabric log fabricprincipal Displays/Enables/Disables Principal SwitchSelection modefabricshow Print fabric membership infofabstateclear Clears the fabric state information fabstateresize Changes the number of state entries fabstateshow Displays the fabric state information fabstatsshow Displays the fabric statistics information fabswitchshow Display fabric switch state information fandisable Disables a fan unit.fanenable Enables a fan unit.fanshow Print fan statusfastboot Reboot this switch and bypass POST fastwritecfg Configure FC fastwrite featurefazoneadd Add a member to a fabric assist zone fazonecreate Create a fabric assist zonefazonedelete Delete a fabric assist zonefazoneremove Remove a member from a fabric assist zone fazoneshow Print Fabric Assist Zone information fcipchiptest Functional Test of Components in FCIP Complex. fciphelp Print FCIP help infofcippathtest Data Path Test of the FCIP complex.fcping Sends a FC ELS ECHO request to a port fcplogclear Clear the FCP logfcplogdisable Disable logging of FCP eventsfcplogenable Enable logging of FCP eventsfcplogshow Display FCP probing log information fcpprobeshow Display FCP probing informationfcprlsshow Display FCP RLS (read link state) information fcrchiptest Functional Test of FCR FPGA.fcrconfigure Sets FC Router configuration parameters. fcrfabricshow Displays FC Routers on a backbone fabric. fcrlsancount Display maximum LSAN zone limit.fcrlsanmatrix Manage LSAN fabric matrix configuration.fcrpathtest Data Path Test on Connection between FCR FPGA andCentral ASIC.fcrphydevshow Displays FC Router physical device information. fcrproxyconfig Displays or configures proxy devices presented byan FC Router.fcrproxydevshow Displays FC Router proxy device information. fcrresourceshow Displays FC Router physical resource usage. fcrrouterportcost Displays FC Router route information.fcrrouteshow Displays FC Router route information.fcrxlateconfig Displays or persistently configures a translate(xlate) domain's domain ID for bothEX_Port-attached fabric and backbone fabric.fddcfg fddcfg manages the fabric data distributionconfiguration parameters.fdmicacheshow Display abbreviated remote FDMI device informationaccording to remote domain IDfdmishow Display detailed FDMI device informationficonclear Clears contents of the specified FICON managementdatabaseficoncupset Sets FICON-CUP parameters for a switchficoncupshow Displays FICON-CUP parameters for a switchficonhelp Displays FICON commandsficonshow Displays contents of the specified FICON managementdatabasefiltertest Run frame filter test for bloom ASICs.firmwarecommit Commit firmware to stable storagefirmwaredownload Download firmware into switch firmwaredownloadstatus Display the progress and status of firmwareDownload firmwarerestore Restore the old firmware in the switchfirmwareshow Display firmware versions in the switchfosconfig Enable/disable FabOS servicesfporttest Functional test of F->N N->F point to point path. framerpathtest Tests data path between ASICsfrureplace Replace a Field Replacable Unitfspfshow Print FSPF global informationfwalarmsfilterset Configure alarms filtering for Fabric Watch fwalarmsfiltershow Show alarms filtering for Fabric Watchfwclassinit Initialize all Fabric Watch classesfwconfigreload Reload Fabric Watch configurationfwconfigure Configure Fabric Watchfwfrucfg Configure FRU state and notificationfwhelp Print Fabric Watch help infofwmailcfg Configure Fabric Watch Email Alertfwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor informationfwset Set port persistence timefwsettocustom Set boundary & alarm level to custom fwsettodefault Set boundary & alarm level to defaultfwshow Show thresholds monitored and port persistence time grep Linux grep commandh Print shell historyhadisable Disables the High Availability feature in theswitch.hadump Displays information about the status of the HighAvailability feature in the switch.haenable Enables the High Availability feature in the switch hafailover Forces the failover mechanism so that the Standby Control Processor (CP)becomes the Active CP.hashow Displays control processor (CP) statushasyncstart Enables HA state synchronization.hasyncstop Disables the HA state synchronization.help Print this listhistorylastshow Displays last history recordhistorymode Display or set the mode of the history log historyshow Displays entire history loghttpcfgshow Used to show the version of the Java plug-in used by the Webtoolsi Display process summaryifmodeset Set the link operating mode for a network interface ifmodeshow Display the link operating mode for a networkinterfaceinterfaceshow Display the FSPF (TM) interface information interopmode Displays/enables/disables Brocade switchinteroperability with switches from othermanufacturersiodreset Turn off the in-order delivery (IOD) optioniodset Turn on the in-order delivery (IOD) optioniodshow Display the state of the in-order delivery option ipaddrset Set ethernet and FC IP addressesipaddrshow Print ethernet and FC IP addressesipfilter Manage/display IP filtersiscsihelp Print iSCSI help infoislshow Display the current connections and statuskilltelnet Terminate telnet/serial login sessionsinteractivelylicenseadd Adds license keys to switchlicensehelp Print license help infolicenseidshow Displays the system license IDlicenseport Configure per-port POD license assignments licenseremove Removes a license key from this systemlicenseshow Displays current license keyslinkcost Set or print the FSPF cost of a linklogin Login as a new userlogout Logout from remote sessionloopporttest Functional test of L-port M->M path on a loop.lsdbshow Displays the FSPF link state databasememshow Display memory usage in the system.minicycle Functional test of internal and external transmitand receive paths at full speed.minispropshow Displays ASIC pair properties.more Linux more commandmscapabilityshow Display Management Server Capability.msconfigure Configure Management Servermsplatshow Display the Management Server Platform Database msplatshowdbcb Display the Management Server Database ControlBlockmsplcleardb Clear the Management Server Platform Databasefabric-widemsplmgmtactivate Activate the Management Server Platform Databasefabric-widemsplmgmtdeactivate Deactivate the Management Server Platform Database fabric-widemstddisable Disables the Management Server Topology DiscoveryManagement Servicemstdenable Enables the Management Server Topology DiscoveryManagement Servicemstdreadconfig Display status of Management Server TopologyDiscovery Servicemyid Display the current login session detailsnbrstateshow Display FSPF (TM) neighbors' statesnbrstatsclear Reset the FSPF (TM) interface countersnetstat Display network connections and statisticsnodefind Display all the devices' PID matching the givenworld wide namensaliasshow Display local Name Server information with Aliases nsallshow Print global Name Server informationnscamshow Print local Name Server Cache informationnsshow Print local Name Server information information nszonemember Display the information of all the online deviceswhich are zoned with the given device.opensource Display information on open source softwareutilized in FabOSpasswd Set usernames and passwordspasswdcfg passwdcfg manages the password policies. pathinfo Display routing information between two ports pdshow Show information from Panic Dump file perfaddeemonitor Add end-to-end monitorperfaddipmonitor Add monitor for IP trafic frame count perfaddreadmonitor Add filter-based monitor - SCSI Read perfaddrwmonitor Add monitor - SCSI Read and Write perfaddscsimonitor Add monitor for SCSI frame count perfaddusermonitor Add filter-based monitorperfaddwritemonitor Add filter-based monitor - SCSI Write perfcfgclear Clear Performance settings from FLASH perfcfgrestore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH perfclearalpacrc Clears the CRC error count associated with a port and Arbitrated Loop Physical Address (AL_PA). perfcleareemonitor Clears statistics counters of one or moreend-to-end performance monitors. perfclearfiltermonitor Clears counters of one or more filter-basedperformance monitors.perfdeleemonitor Delete end-to-end monitorperfdelfiltermonitor Delete filter-based monitorperfhelp Print Performance Monitoring help info perfmonitorclear Clear end-to-end/filter-based/ISL monitors perfmonitorshow Show end-to-end/filter-based/ISL monitors perfsetporteemask Set overall mask for end-to-end monitors perfshowalpacrc Get ALPA CRC count by port and ALPA perfshoweemonitor Show user-defined end-to-end monitors perfshowfiltermonitor Show filter-based monitors perfshowporteemask Show the current end-to-end maskpkicreate Creates public key infrastructure (PKI) objects pkiremove Removes existing public key infrastructure (PKI)objectspkishow Displays existing public key infrastructure (PKI)objectspolicy Configure IPSec encryption and authenticationalgorithmsportalpashow Show the ALPAs of a portportbuffershow Print the buffer allocations for the ports of aquadportcamshow Display filter utilizationportcfg Create/Delete a new ip interface/route/arp entry onthe GigE portportcfgdefault Restore the port configuration to defaults portcfgeport Enable/Disable a port from becoming E_Port portcfgexport Sets a port to be an EX_Port and sets and displays EX_Port configuration parameters.portcfggport Lock a port as a G_Portportcfgislmode Configure a port to be ISL R_RDY Modeenabled/disabledportcfglongdistance Configure a Long Distance Portportcfglport Lock a port as a L_Portportcfgnpivport Enables and disables NPIV functionality on a port. portcfgnport Enable/disable N_Port capability for a port portcfgpersistentdisable Persistently disable a port portcfgpersistentenable Enable a persistently disabled port portcfgshow Displays port configuration settings.portcfgspeed Configure a port to a particular speed level portcfgtrunkport Configure a port for trunkingportcfgvexport Sets a port to be an VEX_Port connected to FC-IP and sets and displays VEX_Port configurationparameters.portcmd Execute commands (ping etc) on the GigE port portdebug Set debug level and verbosity level of port modules portdisable Disable a specified portportenable Enable a specified portporterrshow Print port error summaryportflagsshow Display the port status bitmaps of all ports in aswitchportledtest Cycle user port LEDs.portlogclear Clear port activity logportlogconfigshow Display portlog configurationportlogdisable Disable portlog facilityportlogdump Print port log (no page breaks)portlogdumpport Print port log (no page breaks)portlogenable Enables port log facilityportlogeventshow Display information about port log events portloginshow Display port login informationportlogpdisc Set or clear the debug_pdisc_flagportlogreset Enable portlog facilityportlogresize Resize the port logportlogshow Print port activity logportlogshowport Print port activity logportlogtypedisable Disable port loggingportlogtypeenable Enable port loggingportloopbacktest Functional test of port N->N path.portmirror Set a port's configuration to be disabled orenabledportname Assign or display the name associated with a port portperfshow Print port throughput numbersportregtest Write/read test of the ASIC SRAMs portregtest. portrouteshow Display various routing tables for a portportshow Show configured ip interfaces/routes/arp entries onthe GigE Portportstats64show Display the 64-bit hardware statistics for a port portstatsclear Clear the status of a specified switch port portstatsshow Print hardware statisticsportswap Swaps area numbersportswapdisable Disable portswap featureportswapenable Enable portswap featureportswapshow Display port and area informationporttest Functional test on a live fabric. Starts porttest. porttestshow Retreive information from porttest.portzoneshow Displays the enforced zone type of the F/FL-portsof a switch.powerofflistset sets slot power off list orderpowerofflistshow Displays slot power-off order.psshow Print power supply statusquietmode Displays/enables/disables quietmode on telnetsessionreboot Reboot this processorroutehelp Print routing help infosaschiptest Functional Test of Components in SAS Complex. saspathtest Data Path Test of the SAS complex.secactivesize Displays size of the active (security) database secauthsecret Creates/Manages DHCHAP secret key details seccertutil Creates/Manages/Displays third party PKIcertificatessecdefinesize Displays size of the defined (security) database secfabricshow Displays security related fabric information secfcsfailover Forces primary role to this FCS switchsecglobalshow Displays current internal security stateinformationsechelp Displays information about security commands secmodedisable Disables secure modesecmodeenable Enables secure modesecmodeshow Displays whether secure mode is enabled or disabled secnonfcspasswd Sets the admin passwd for non-FCS switches secpolicyabort Aborts changes to defined policysecpolicyactivate Activates all policy setssecpolicyadd Adds members to an existing policysecpolicycreate Creates a new policysecpolicydelete Deletes an existing policysecpolicydump Displays all members of existing policies secpolicyfcsmove Moves a member in the FCS policy secpolicyremove Removes members from an existing policy secpolicysave Saves defined policy set and sends to all switches secpolicyshow Shows members of one or more policies secstatsreset Resets security statisticssecstatsshow Displays security statisticssectemppasswdreset Resets temporary password sectemppasswdset Sets temporary passwordsectransabort Aborts current transactionsecversionreset Resets version stampsensorshow Display sensor readingssetdbg Set debug level of the specified modulesetesdmode Set or display ESD mode.setmfgmode Set or display diagnostic MFG mode.setmodem Enables or disables modem login to a controlprocessor (CP)setsplbmode Set or display SPLB mode.setverbose Set verbosity level of the specified modulesfpshow Print Serial ID SFP information shellflowcontroldisable Disable xon-xoff flow control on console serialportshellflowcontrolenable Enable xon-xoff flow control on console serial port slotpoweroff Removes power from a slot.slotpoweron Restores power to a slot.slotshow Displays the status of all slots in the system.sltest Serial link test of port N->N path.snmpconfig Configure SNMPsnmpmibcapset Set options for configuring SNMP Mib/TrapCapabilitysnmpmibcapshow Show SNMP Mib/Trap Configurationspinfab Functional test of switch to switch ISL cabling andtrunk group operation.spinjitter line-speed jitter measurementspinsilk Functional test of internal and external transmitand receive paths at full speedsramretentiontest Data retention test of the miscellaneous SRAMs in ASIC.statsclear Clear port and diagnostic statistics.statstest Statistics counter test for the ASICs.stopporttest Terminate the running porttest.supportffdc Modifies or displays first-failure data capture(FFDC) configuration.supportftp set support Ftp parameterssupportsave retrieve support data from switch to hostsupportshow Prints switch information for debugging purposes. supportshowcfgdisable Disables a group of commands under supportshow command.supportshowcfgenable Enables a group of commands under supportshow command.supportshowcfgshow Displays the groups of commands enabled fordisplay. by the supportshow command.switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switch switchcfgpersistentenable Enable a persistently disabled switch switchcfgspeed Configures all ports of the switch to a particularspeed levelswitchcfgtrunk Configure all ports on the switch for trunking switchdisable Disable this switchswitchenable Enable this switchswitchname Print/set this switch's nameswitchreboot Halts and restarts the operational switch.switchshow Print switch and port statusswitchstatuspolicyset Set policy parameters for overall switch status switchstatuspolicyshow Print policy parameters for overall switch status switchstatusshow Print overall switch statusswitchuptime Display the amount of time for which the switch isupsyslogdfacility Change the syslog facilitysyslogdipadd Add syslog daemon IP addresssyslogdipremove Remove syslog daemon IP addresssyslogdipshow Print the syslog daemon targetssysshutdown Provides a graceful shutdown to protect the switchfile systems.systemverification Run a suit of diagnostic tests on all switches in asystem.tempshow Print temperature readingstimeout Set/show the IDLE timeout value for a login session topologyshow Display the unicast fabric topologytracedump generate/remove trace dump or display trace dumpstatustrackchangeshelp Print Track Changes help infotrackchangesset Configure alert for login/logout/config update trackchangesshow Displays status of track changestrunkdebug Debug a trunk link failuretrunkshow Display trunking informationtsclockserver Displays or sets the NTP server address tstimezone Displays or sets the time zoneturboramtest Turbo SRAM test for bloom ASICs.txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been upurouteconfig Configure a static routeurouteremove Remove a static routeurouteshow Display unicast routing informationuserconfig Display or configure user accountsuserrename Rename user login nameversion Print firmware versionwwn Display or set the world wide namezone Copies/Removes/Validates zone objectszoneadd Add a member to a zonezonecreate Create a zonezonedelete Delete a zonezonehelp Print zoning help infozoneobjectcopy Copies a zone objectzoneobjectexpunge Expunges a zone object zoneobjectrename Rename a zoning Objectzoneremove Remove a member from a zonezoneshow Print zone information。
brocade光纤交换机基本配置
1,改修端口速率:brocade4Gb:admin> portcfgspeed 2 2 ####端口号速率2,改修Domain ID:brocade4Gb:admin> switchdisablebrocade4Gb:admin> configureConfigure...Fabric parameters (yes, y, no, n): [no] yes Domain: (1..239) [2] 3R_A_TOV: (4000..120000) [10000]E_D_TOV: (1000..5000) [2000]WAN_TOV: (0..30000) [0]MAX_HOPS: (7..19) [7]Data field size: (256..2112) [2112]Sequence Level Switching: (0..1) [0]Disable Device Probing: (0..1) [0]Suppress Class F Traffic: (0..1) [0]Per-frame Route Priority: (0..1) [0]Long Distance Fabric: (0..1) [0]BB credit: (1..27) [16]Insistent Domain ID Mode (yes, y, no, n): [no]Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no]Zoning Operation parameters (yes, y, no, n): [no] RSCN Transmission Mode (yes, y, no, n): [no]Arbitrated Loop parameters (yes, y, no, n): [no] System services (yes, y, no, n): [no]Portlog events enable (yes, y, no, n): [no]ssl attributes (yes, y, no, n): [no]rpcd attributes (yes, y, no, n): [no]cfgload attributes (yes, y, no, n): [no]webtools attributes (yes, y, no, n): [no]Custom attributes (yes, y, no, n): [no]System (yes, y, no, n): [no]WARNING: The domain ID will be changed. The port level zoning may be affectedbrocade4Gb:admin> savehistorybrocade4Gb:admin> switchenable3,配置及查看IP地址brocade4Gb:admin> ipaddrsetbrocade4Gb:admin> ipaddrshow4,配置zonebrocade4Gb:admin> zonecreate "testzone2","3,2;3,0" 创建zone名为testzone2,成员为3,2和3,0端口brocade4Gb:admin> zoneremove "testzone2","3,2" 删除zone名为testzone2中的成员:3,2 brocade4Gb:admin> zoneadd "testzone2","3,2" 增加zone名为testzone2中的成员:3,2 brocade4Gb:admin> zonecreate "testzone1","3,1;3,0"brocade4Gb:admin> cfgcreate "zoneconf1","testzone1;testzone2" 创建一个zone配置为:zoneconf1;成员为:testzone1和testzone2brocade4Gb:admin> cfgremove "zoneconf1","testzone1" 删除zone配置:zoneconf1中的成员:testzone1brocade4Gb:admin> cfgadd "zoneconf1","testzone1" 增加zone配置:zoneconf1中的成员:testzone1brocade4Gb:admin> cfgenable zoneconf1 应用zone配置:zoneconf1 brocade4Gb:admin> cfgsave 保存配置:zoneconf1。
Cisco思科光纤交换机配置常用命令介绍
Cisco思科光纤交换机配置常用命令介绍交换机除了能够连接同种类型的网络之外,还可以在不同类型的网络(如以太网和快速以太网)之间起到互连作用。
你还在为不知道Cisco思科光纤交换机配置说明而烦恼么?下面小编为大家收集的Cisco思科光纤交换机配置说明教程,希望能帮到大家,一起来看看吧!Cisco思科光纤交换机配置说明的方法1. 初始化信息首次设置,必须通过console进行连接(需要U口转DB9针的接口线,专门卖接口线的有卖大约30元),然后进行初始化设计,以后设定IP后可通过LAN进行登陆具体步骤:(红色字体部分着重注意,需要进行设置,大部分按照默认设置即可,而且设置的部分进入管理工具软件可以更改) ---- System Admin Account Setup ----Enter the password for "admin": passwordConfirm the password for "admin": password--- Basic System Configuration Dialog ---This setup utility will guide you through the basic configuration of the system. Setup configures only enough connectivity for management of the system.Press Enter at any time to skip any dialog. Use ctrl-c at anytime to skip the remaining dialogs.Would you like to enter the basic configuration dialog (yes/no): yCreate another login account (yes/no) [n]:Configure read-only SNMP community string (yes/no) [n]:Configure read-write SNMP community string (yes/no) [n]: Enter the switch name: Pxx-MDS-x (where xx is your pod number and x is the switch number; for example:P01-MDS-1) Continue with Out-of-band (mgmt0) managementconfiguration? (yes/no) [y]:Mgmt0 IPv4 address : <10.0.x.y> (where x is your pod number and y is 5 for MDS-1 and 3 for MDS-2)(客户)0.16 Mgmt0 IPv4 netmask : 255.255.255.0Configure the default gateway? (yes/no) [y]:IPv4 address of the default gateway : 10.0.x.254 (where x is your pod number)Configure advanced IP options? (yes/no) [n]:Enable the telnet service? (yes/no) [y]:Enable the ssh service? (yes/no) [n]:Configure the ntp server? (yes/no) [n]:Configure default switchport interface state (shut/noshut) [shut]: (注意一下)noshutConfigure default switchport trunk mode (on/off/auto) [on]: Configure default zone policy (permit/deny) [deny]:Enable full zoneset distribution (yes/no) [n]:NOTE:初始设定的配置对新的VSAN起作用,即原始VSAN1无这些配置解决办法:1 zone default-zone permit VSAN2 新建 NEW VSAN2 将port转移VSAN2里面。
光纤交换机常用命令
光纤交换机常用命令分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。
需改为不同号。
下面是博科的交换机命令转。
Brocade SAN交换机常用命令使用电脑连接管理网口,默认IP地址为:192.168.0.1,掩码:255.255.255.0默认用户名:admin,默认密码password1. switchStatusShow2. switchShow3. portShow4. fanShow5. psShow查看交换机的电源状态4个电源6. tempShow7. errDump、errShow、errClear8. supportShow、supportSave、pdShow9. nsShow、nsAllShow、fabricShow10. licenseShow、wwn检查license文件和交换机的WWN号11. version12. haShow13. slotShow查看各个Blade的状态14. portCfgSpeed修改端口的速率15. portEnable或portCfgPersistentEnable Reset端口16. 检查WWN卡状态下列命令如果不能正确执行,则说明WWN卡需要更换:www,chassisShow:显示交换机的WWN号chassisShow:显示chassis和WWN卡的状态ipAddrShow,ipAddrSet:显示CP Blades的IP地址historyShow、historyLastShow:显示历史日志信息switchName:显示交换机的名字修改Domain ID1. 查看当前的Domain ID输入命令fabricShow,输出结果中的Switch ID即包括交换机的Domain ID。
2. 先关闭交换机输入命令swichDisable3. 配置Domain ID4. 重新启用交换机输入命令swichEnable升级FirmwareFC10-6 Blade需要Firmware Version 5.3以上FC4-16IP Blade、FC4-48 Port Blade需要Firmware Version 5.2以上FR4-18i router blade需要Firmware Version 5.1以上如果M48有主备Control Processor,且主备CP处于synchronized状态,则升级过程可在线进行,不干扰数据流量。
光纤交换机级联配置文档CISCO
光纤交换机级联配置文档Cisco 9120交换机1.配置异构交换机平台协同工作模式Cisco 9120配置过程激活前8个端口switch# config tEnter configuration commands, one per line. End with CNTL/Z. switch(config)#interface fc1/1-8switch(config-if)# no shutdownswitch(config-if)# end配置交换机协同工作模式switch# config tEnter configuration commands, one per line. End with CNTL/Z. switch(config)# vsan databaseswitch(config-vsan-db)# vsan 1 interopswitch(config-vsan-db)# end配置domain IDswitch# config tEnter configuration commands, one per line. End with CNTL/Z. switch(config)# fcdomain domain 100 preferred vsan 1switch(config)# end激活VSANswitch# config tEnter configuration commands, one per line. End with CNTL/Z. switch(config)# vsan databaseswitch(config-vsan-db)# vsan 1 suspendswitch(config-vsan-db)# no vsan 1 suspendswitch(config-vsan-db)# end察看修改之后的系统配置信息switch# show runningversion 2.0(2b)vsan databasevsan 1 interop 1fcdomain domain 100 preferred vsan 1fcdomain fcid persistent vsan 1boot kickstart bootflash:/m9100-s1ek9-kickstart-mz.2.0.2b.bin boot system bootflash:/m9100-s1ek9-mz.2.0.2b.binkernel core target 0.0.0.0kernel core limit 1snmp-server user admin network-admin auth md5 0xeec64ba2afbe9b65e13b23882ac6ae05priv 0xeec64ba2afbe9b65e13b23882ac6ae05 localizedkeyusername admin password 5 $1$V3smTQpb$MTvub69DkVBxdCt9BsEDB1 role network-admincallhomeswitch-priority 7snmp-server enable traps licenseinterface mgmt0ip address 192.168.70.139 255.255.255.0interface fc1/1no shutdowninterface fc1/2no shutdowninterface fc1/3no shutdowninterface fc1/4no shutdowninterface fc1/5no shutdowninterface fc1/6no shutdowninterface fc1/7no shutdowninterface fc1/8no shutdowninterface fc1/9interface fc1/10interface fc1/11interface fc1/12interface fc1/13interface fc1/14interface fc1/15interface fc1/16interface fc1/17interface fc1/18interface fc1/19interface fc1/20switch#察看端口连接状态信息switch# show interface brief------------------------------------------------------------------------------- Interface Vsan Admin Admin Status FCOT Oper Oper Port Mode Trunk Mode Speed ChannelMode (Gbps)-------------------------------------------------------------------------------fc1/1 1 auto on up swl F 2 --fc1/2 1 auto on up swl F 2 --fc1/3 1 auto on up swl E 2 --fc1/4 1 auto on notConnected swl -- --fc1/5 1 FX -- notConnected swl -- --fc1/6 1 FX -- notConnected swl -- --刀片中心光纤交换机模块配置禁止交换机brocadessm:USERID> switchdisable修改Domain IDbrocadessm:USERID> configureConfigure...Fabric parameters (yes, y, no, n): [no] yesDomain: (1..239) [1] 99R_A_TOV: (4000..120000) [10000]E_D_TOV: (1000..5000) [2000]WAN_TOV: (0..30000) [0]MAX_HOPS: (7..19) [7]Data field size: (256..2112) [2112]Sequence Level Switching: (0..1) [0]Disable Device Probing: (0..1) [0]Suppress Class F Traffic: (0..1) [0]Switch PID Format: (1..2) [1]Per-frame Route Priority: (0..1) [0]Long Distance Fabric: (0..1) [0]BB credit: (1..27) [16]Insistent Domain ID Mode (yes, y, no, n): [no]Virtual Channel parameters (yes, y, no, n): [no]Zoning Operation parameters (yes, y, no, n): [no]RSCN Transmission Mode (yes, y, no, n): [no]Arbitrated Loop parameters (yes, y, no, n): [no]System services (yes, y, no, n): [no]Portlog events enable (yes, y, no, n): [no]ssl attributes (yes, y, no, n): [no]http attributes (yes, y, no, n): [no]snmp attributes (yes, y, no, n): [no]rpcd attributes (yes, y, no, n): [no]cfgload attributes (yes, y, no, n): [no]webtools attributes (yes, y, no, n): [no]WARNING: The domain ID will be changed. The port level zoning may be affectedbrocadessm:USERID> msPlMgmtDeactivateSwitch is in Offline state.修改协同工作模式brocadessm:USERID> interoper mode 1The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] yInteropmode is enabledNote: It is recommended that you reboot this switch for the new change to take effect.重新引导交换机brocadessm:USERID> fastbootBroadcast message from root (pts/0) Tue Jun 13 10:07:45 2006...The system is going down for reboot NOW !!USERIDPassword:Please change your passwords now.Use Control-C to exit or press 'Enter' key to proceed.Password was not changed. Will prompt again at next loginuntil password is changed.brocadessm:USERID>brocadessm:USERID> switchenable察看修改配置之后的交换机状态brocadessm:USERID> switchshowswitchName: brocadessmswitchType: 22.0switchState: OnlineswitchMode: InteropswitchRole: PrincipalswitchDomain: 99switchId: fffc63switchWwn: 10:00:00:05:1e:02:78:c6zoning: OFFswitchBeacon: OFFArea Port Media Speed State==============================0 0 id 2G No_Light1 1 cu 2G Online F-Port 21:00:00:14:5e:24:a9:042 2 cu 2G Online F-Port 21:00:00:14:5e:24:a9:363 3 cu 2G Online F-Port 21:00:00:14:5e:24:a9:7a4 4 cu 2G Online F-Port 21:00:00:14:5e:24:a9:b65 5 cu 2G Online F-Port 21:00:00:14:5e:24:a9:286 6 cu 2G Online F-Port 21:00:00:14:5e:24:aa:f67 7 cu 2G Online F-Port 21:00:00:14:5e:24:aa:f08 8 cu 2G Online F-Port 21:00:00:14:5e:24:a9:389 9 cu 2G No_Light10 10 cu 2G No_Light11 11 cu 2G No_Light12 12 cu 2G No_Light13 13 cu 2G No_Light14 14 cu 2G No_Light15 15 id 2G Online E-Port 20:01:00:0d:ec:06:b4:41 (downstream)2.划分zoneCisco 9120划分zone察看fabric连接设备port wwn 信息switch# show fcns database vsan 1--------------------------------------------------------------------------FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE--------------------------------------------------------------------------0x630100 N 21:00:00:14:5e:24:a9:04 scsi-fcp0x630200 N 21:00:00:14:5e:24:a9:36 scsi-fcp0x630300 N 21:00:00:14:5e:24:a9:7a scsi-fcp0x630400 N 21:00:00:14:5e:24:a9:b6 scsi-fcp0x630500 N 21:00:00:14:5e:24:a9:28 scsi-fcp0x630600 N 21:00:00:14:5e:24:aa:f6 scsi-fcp0x630700 N 21:00:00:14:5e:24:aa:f0 scsi-fcp0x630800 N 21:00:00:14:5e:24:a9:38 scsi-fcp0x640000 N 20:07:00:a0:b8:21:19:9f (SymBios) scsi-fcp:both0x640100 N 20:06:00:a0:b8:21:19:9f (SymBios) scsi-fcp:bothTotal number of entries = 10创建zone分别创建2个zone,前4个刀片服务器与DS4300 2个控制器组成的zone,第4到第8个刀片服务器与DS4300 2个控制器组成的zone。
Brocade B24光纤交换机基本命令行配置及示例
Brocade B24光纤交换机CMD配置编写人审批人所属部门修改内容修改时间版本号张屹网络部DBA组新建文档20170714V0.1光纤交换机常用操作命令,下面以博科(Brocade)的光纤交换机操作说明,IBM和HP的光纤交换机都是OEM博科的,操作命令类似。
命令uptime 显示交换机工作时间ipaddrshow 显示交换机IP地址信息licenseshow 显示当前交换机所添加的license信息switchshow 检查交换机信息及端口状态switchstatusshow 显示交换机的运行状态firmwareshow 显示微码版本fanshow 显示风扇运行状态tempshow 显示交换机当前温度信息psshow 显示电源运行状态slotshow 显示板卡运行状态hashshow 显示CP版卡HA状态,errdump 显示错误日志fabricshow 显示fabric信息及级联信息cfgshow 显示交换机配置信息porterrshow 显示交换机端口的错误统计chassisshow 显示外壳信息及序列号version 相看版本userconfig --show -a 查看登录帐号domainsshow 查看交换机的domain信息aliashow 查看别名snmpconfig --disable snmpv1 关闭SNMPV1级联互ping:fcping --number 10000 --length 2036 --interval 1 10:00:00:05:33:9f:06:28级联更改portcfglongdistance 0备份configuplocadProtocol (scp or ftp):ftphost:user name:filename:password:恢复switchdisable 停用交换机configdownloadProtocol (scp or ftp):ftpServer Name or IP Address [host]:User Name [user]:File Name [config.txt]:config.txt.........Do you want to continue [y/n]:yPassword:设置IPipaddrsetEthernet IP Address [10.77.77.77]:Ethernet Subnetmask [255.255.255.0]:Fibre Channel IP Address [none]:Fibre Channel Subnetmask [none]:Fibre Channel Subnetmask [none]:Gataway IP Address []:DHCP [On]Zone配置示例:创建别名alicreate "member1","1,1;1,2;1,3"alicreate "member2","1,2;1,3;1,4"alicreate "member3","1,3;1,4;1,5"alishow划分zonezonecreate "zone1","member1;member2"zonecreate "zone2","1,1;1,7"zonecreate "zone2","member3;1,8"zoneshow将zone添加到配置中cfgcreate "conf1","zone1;zone2;zone3"cfgshow启用配置cfgenable conf1存储配置cfgsave删除cfgIBM_2005_H16:admin> cfgRemove "H16_cfg","vmtest"IBM_2005_H16:admin> cfgsaveIBM_2005_H16:admin> cfgenable H16_cfg删除zoneIBM_2005_H16:admin> zonedelete vmtest配置示例11、新服务器的HBA卡接入光交,将其和IBM V5000存储的HBA接口划分在同一个ZONE,与其它服务器分开。
光纤交换机配置
光纤交换机配置谈起交换机本地配置,首先我们来看一下交换机的物理连接。
交换机的本地配置方式是通过计算机与交换机的“Console”端口直接连接的方式进行通信的。
下面是店铺跟大家分享的是光纤交换机配置,欢迎大家来阅读学习。
光纤交换机配置工具/原料Windows电脑交换机第1步:1第1步:单击“开始”按钮,在“程序”菜单的“附件”选项中单击“超级终端”,弹出如图所示界面。
2第2步:双击“Hypertrm”图标,弹出如图所示对话框。
这个对话框是用来对立一个新的超级终端连接项。
3第3步:在“名称”文本框中键入需新建超的级终端连接项名称,这主要是为了便于识别,没有什么特殊要求,我们这里键入“Cisco”,如果您想为这个连接项选择一个自己喜欢的图标的话,您也可以在下图的图标栏中选择一个,然后单击“确定”按钮,弹出如图所示的对话框。
4第4步:在“连接时使用”下拉列表框中选择与交换机相连的计算机的串口。
单击“确定”按钮,弹出如图所示的对话框。
5第5步:在“波特率”下拉列表框中选择“9600”,因为这是串口的最高通信速率,其他各选项统统采用默认值。
单击“确定”按钮,如果通信正常的话就会出现类似于如下所示的主配置界面,并会在这个窗口中就会显示交换机的初始配置情况。
Catalyst 1900 Management ConsoleCopyright (c) Cisco Systems,Inc。
1993-1999All rights reserved。
Standard Edition SoftwareEthernet address:00-E0-1E-7E-B4-40PCA Number:73-2239-01PCA Serial Number:SAD01200001Model Number:WS-C1924-ASystem Serial Number:FAA01200001User Interface Menu[M] Menus//主配置菜单[I] IP Configuration//IP地址等配置[P] Console Password //控制密码配置Enter Selection://在此输入要选择项的快捷字母,然后按回车键确认至此就正式进入了交换机配置界面了,下面的工作就可以正式配置交换机了。
博科光纤交换机配置命令一览
DS_200B:admin> helpaaaconfig ad Configure RADIUS for AAA servicesSpecifies all administration domain (AD)-level operationsag agshow Configure the Access Gateway featureDisplays the Access Gateway information registeredwith the fabricagtcfgdefault aliaddalicreate alidelete aliremove alishow aptpolicy auditcfg Reset SNMP agent to factory defaultAdd a member to a zone aliasCreate a zone aliasDelete a zone aliasRemove a member from a zone aliasPrint zone alias informationGet and set Advanced Performance Tuning policy Modifies and displays audit log filter configuration.authutil backplanetest backport bannerset bannershow bcastshow bladebeacon Get and set authentication configurationBackplane connection test for multi-blade systems. Test for back-end ASIC pair to ASIC pair links.Set security bannerDisplay security bannerDisplay broadcast routing informationEnables or disables blade beaconing or displays the current mode.bladedisable bladeenableburninerrclear Disables all user ports on a blade.Enables all User Ports on a blade.Clear errors that are stored in the non-volatile storage burninerrshow Display errors that are stored in the non-volatilestorageburninstatus camtest Display the diagnostics burnin status.Verify QuickLoop's Content Addressable Memory (CAM).SID translationcentralmemorytest cfgactvshow cfgadd cfgclear cfgcreate cfgdelete cfgdisable cfgenable cfgremove cfgsave cfgshow Test ASIC central memory operation.Display Effective zone configuration information Add a member to a configurationClear all zone configurationsCreate a zone configurationDelete a zone configurationDisable a zone configurationEnable a zone configurationRemove a member from a configurationSave zone configurations in flashPrint zone configuration informationcfgsize cfgtransabortcfgtransshow chassisconfig chassisname chassisshow chipregshowPrint size details of zone databaseAbort zone configuration transactionPrint zone configurations in transaction buffer Display or set the chassis configurationDisplay or set the chassis's NameDisplay all Field Replaceable Units (FRU) Displays the port registers for a given chip number.cmemretentiontestcmitest configdefault configdownload configshow configupload configure datatypeshow date dbgshow defzoneData retention test of the central memory SRAMs. Verify CMI bus between ASICs.Reset config to factory defaultLoad switch config from a serverPrint switch config parametersSave switch config to a serverSet switch config parametersDisplay available diagnostic data types.Print/set the system date and timeDisplay debug levels of various modules Activates or deactivates a default zone configuration.diagclearerrordiagcommandshow diagdisablepost diagenablepost diagenv diaghelp diagloopid diagmodeshow diagpost Clears diagnostics failure status.Display diagnostic command descriptions.Disable diagnostic POST.Enable diagnostic POST.Diagnostic debug parameters management package. Display diagnostic command descriptions.Select the diagnostics loop ID.Displays diagnostic mode configuration.Displays the contents of port registers and memories.diagretry diagsetburnin diagsetcyclediagsetesdmode diagsetshowtime diagshow diagshowtime diagstatus diagstopburnin distribute dlsreset dlsset dlsshow Sets diagnostic retry modeInitializes the blade for a burnin run.Set diagnostic script parameters.Set or display ESD mode.Set or display diagnostic show-time mode.Display diagnostic status.Set or display diagnostic show-time mode. Display currently running diagnostic tests. Terminate burnin run on a blade. Distributes data to switches in a fabric. Turn off the dynamic load sharing (DLS) option Turn on the dynamic load sharing (DLS) optionDisplay the state of the dynamic load sharing optionConfigure DNS service Display the switch enclosure attributes Clear error log Sets the error log start and end delimiter for messages sent to the console and syslog Print error log (no page breaks) Sets a filter for an error log destination Displays all the defined modules in the system Print error log Display contents of a particular port's data Display retry count of various fabric commands Displays or manipulates the fabric log Displays/Enables/Disables Principal Switch Selection mode Print fabric membership info Clears the fabric state information Changes the number of state entries Displays the fabric state information Displays the fabric statistics information Display fabric switch state information Disables a fan unit. Enables a fan unit. Print fan status Reboot this switch and bypass POST Configure FC fastwrite feature Add a member to a fabric assist zone Create a fabric assist zone Delete a fabric assist zone Remove a member from a fabric assist zone Print Fabric Assist Zone information Functional Test of Components in FCIP Complex. Print FCIP help info Data Path Test of the FCIP complex. Sends a FC ELS ECHO request to a port Clear the FCP log Disable logging of FCP events Enable logging of FCP events Display FCP probing log information Display FCP probing information Display FCP RLS (read link state) information Functional Test of FCR FPGA. Sets FC Router configuration parameters. Displays FC Routers on a backbone fabric. Display maximum LSAN zone limit.dnsconfigenclosureshowerrclearerrdelimiterseterrdumperrfilterseterrmoduleshowerrshowfabportshowfabretryshowfabriclogfabricprincipalfabricshowfabstateclearfabstateresizefabstateshowfabstatsshowfabswitchshowfandisablefanenablefanshowfastbootfastwritecfgfazoneaddfazonecreatefazonedeletefazoneremovefazoneshowfcipchiptestfciphelpfcippathtestfcpingfcplogclearfcplogdisablefcplogenablefcplogshowfcpprobeshowfcprlsshowfcrchiptestfcrconfigurefcrfabricshowfcrlsancountfcrlsanmatrix fcrpathtest Manage LSAN fabric matrix configuration.Data Path Test on Connection between FCR FPGA andCentral ASIC.fcrphydevshow fcrproxyconfigDisplays FC Router physical device information. Displays or configures proxy devices presented by an FC Router.fcrproxydevshow fcrresourceshow fcrrouterportcost fcrrouteshow fcrxlateconfigDisplays FC Router proxy device information. Displays FC Router physical resource usage. Displays FC Router route information.Displays FC Router route information.Displays or persistently configures a translate (xlate) domain's domain ID for both EX_Port-attached fabric and backbone fabric.fddcfg fddcfg manages the fabric data distributionconfiguration parameters.fdmicacheshow Display abbreviated remote FDMI device informationaccording to remote domain IDfdmishow ficonclear Display detailed FDMI device informationClears contents of the specified FICON managementdatabaseficoncupset ficoncupshow ficonhelp ficonshow Sets FICON-CUP parameters for a switch Displays FICON-CUP parameters for a switch Displays FICON commandsDisplays contents of the specified FICON management databasefiltertest firmwarecommit firmwaredownload firmwaredownloadstatus firmwarerestore firmwareshow fosconfig fporttest framerpathtest frureplace fspfshow fwalarmsfilterset fwalarmsfiltershow fwclassinit fwconfigreload fwconfigure fwfrucfg fwhelp fwmailcfg Run frame filter test for bloom ASICs.Commit firmware to stable storageDownload firmware into switchDisplay the progress and status of firmwareDownload Restore the old firmware in the switchDisplay firmware versions in the switch Enable/disable FabOS servicesFunctional test of F->N N->F point to point path.Tests data path between ASICsReplace a Field Replacable UnitPrint FSPF global informationConfigure alarms filtering for Fabric WatchShow alarms filtering for Fabric WatchInitialize all Fabric Watch classesReload Fabric Watch configurationConfigure Fabric WatchConfigure FRU state and notificationPrint Fabric Watch help infoConfigure Fabric Watch Email Alertfwportdetailshow fwsamshow fwset fwsettocustom fwsettodefault fwshow Create a report with detailed port informationShow availability monitor informationSet port persistence timeSet boundary & alarm level to customSet boundary & alarm level to defaultShow thresholds monitored and port persistence timegreph hadisableLinux grep commandPrint shell historyDisables the High Availability feature in the switch.hadump Displays information about the status of the HighAvailability feature in the switch.haenable hafailover Enables the High Availability feature in the switchForces the failover mechanism so that the StandbyControl Processor (CP)becomes the Active CP.hashow hasyncstart hasyncstop help historylastshow historymode historyshow httpcfgshowiDisplays control processor (CP) statusEnables HA state synchronization.Disables the HA state synchronization.Print this listDisplays last history recordDisplay or set the mode of the history logDisplays entire history logUsed to show the version of the Java plug-in used by the WebtoolsDisplay process summaryifmodeset ifmodeshow Set the link operating mode for a network interfaceDisplay the link operating mode for a networkinterfaceinterfaceshowinteropmode Display the FSPF (TM) interface informationDisplays/enables/disables Brocade switch interoperabilitywith switches from other manufacturersiodreset iodset iodshowipaddrset ipaddrshowipfilter iscsihelp islshow killtelnetTurn off the in-order delivery (IOD) optionTurn on the in-order delivery (IOD) optionDisplay the state of the in-order delivery option Set ethernet and FC IP addressesPrint ethernet and FC IP addresses Manage/display IP filters Print iSCSI help infoDisplay the current connections and status Terminate telnet/serial login sessions interactivelylicenseadd licensehelpAdds license keys to switch Print license help infolicenseidshow licenseport licenseremove licenseshow linkcost login logout loopporttest lsdbshow memshow minicycleDisplays the system license IDConfigure per-port POD license assignments Removesa license key from this system Displays current licensekeysSet or print the FSPF cost of a linkLogin as a new userLogout from remote sessionFunctional test of L-port M->M path on a loop. Displays the FSPF link state database Display memory usage in thesystem.Functional test of internal and external transmit andreceive paths at full speed.minispropshow moremscapabilityshow msconfigure msplatshow msplatshowdbcb Displays ASIC pair properties.Linux more commandDisplay Management Server Capability.Configure Management ServerDisplay the Management Server Platform Database Display the Management Server Database Control Blockmsplcleardb Clear the Management Server Platform Databasefabric-widemsplmgmtactivate Activate the Management Server Platform Databasefabric-widemsplmgmtdeactivate Deactivate the Management Server Platform Databasefabric-widemstddisable Disables the Management Server Topology DiscoveryManagement Servicemstdenable Enables the Management Server Topology DiscoveryManagement Servicemstdreadconfig Display status of Management Server TopologyDiscovery Servicemyid nbrstateshow nbrstatsclear netstat nodefindDisplay the current login session detailsDisplay FSPF (TM) neighbors' statesReset the FSPF (TM) interface countersDisplay network connections and statisticsDisplay all the devices' PID matching the given world wide namensaliasshow nsallshow nscamshow nsshow nszonemember Display local Name Server information with Aliases Print global Name Server informationPrint local Name Server Cache informationPrint local Name Server information information Display the information of all the online devices which are zoned with the given device.opensource Display information on open source softwareutilized in FabOS Set usernames and passwords passwdcfg manages the password policies. Display routing information between two ports Show information from Panic Dump file Add end-to-end monitor Add monitor for IP trafic frame count Add filter-based monitor - SCSI Read Add monitor - SCSI Read and Write Add monitor for SCSI frame count Add filter-based monitor Add filter-based monitor - SCSI Write Clear Performance settings from FLASH Restore Performance configuration from FLASH Save Performance configuration to FLASH Clears the CRC error count associated with a port and Arbitrated Loop Physical Address (AL_PA). Clears statistics counters of one or more end-to-end performance monitors. Clears counters of one or more filter-based performance monitors. Delete end-to-end monitor Delete filter-based monitor Print Performance Monitoring help info Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for end-to-end monitors Get ALPA CRC count by port and ALPA Show user-defined end-to-end monitors Show filter-based monitors Show the current end-to-end mask Creates public key infrastructure (PKI) objects Removes existing public key infrastructure (PKI) objects Displays existing public key infrastructure (PKI) objects Configure IPSec encryption and authentication algorithms Show the ALPAs of a port Print the buffer allocations for the ports of a quad Display filter utilizationCreate/Delete a new ip interface/route/arp entry on the GigE portpasswd passwdcfgpathinfo pdshowperfaddeemonitorperfaddipmonitorperfaddreadmonitorperfaddrwmonitorperfaddscsimonitorperfaddusermonitorperfaddwritemonitorperfcfgclearperfcfgrestoreperfcfgsaveperfclearalpacrcperfcleareemonitorperfclearfiltermonitorperfdeleemonitorperfdelfiltermonitorperfhelpperfmonitorclearperfmonitorshowperfsetporteemaskperfshowalpacrcperfshoweemonitorperfshowfiltermonitorperfshowporteemaskpkicreate pkiremovepkishowpolicyportalpashowportbuffershowportcamshow portcfgportcfgdefault portcfgeport portcfgexportRestore the port configuration to defaultsEnable/Disable a port from becoming E_Port Sets a port to be an EX_Port and sets and displays EX_Port configuration parameters.portcfggport portcfgislmode Lock a port as a G_PortConfigure a port to be ISL R_RDY Mode enabled/disabledportcfglongdistance portcfglport portcfgnpivport portcfgnport portcfgpersistentdisable portcfgpersistentenable portcfgshow portcfgspeed portcfgtrunkport portcfgvexportConfigure a Long Distance PortLock a port as a L_PortEnables and disables NPIV functionality on a port.Enable/disable N_Port capability for a port Persistently disable a portEnable a persistently disabled portDisplays port configuration settings.Configure a port to a particular speed level Configure a port for trunkingSets a port to be an VEX_Port connected to FC-IPand sets and displays VEX_Port configurationparameters.portcmd portdebugportdisable portenable porterrshow portflagsshowExecute commands (ping etc) on the GigE port Set debug level and verbosity level of port modules Disable a specified port Enable a specified portPrint port error summaryDisplay the port status bitmaps of all ports in aswitchportledtest portlogclear portlogconfigshow portlogdisable portlogdump portlogdumpport portlogenable portlogeventshow portloginshow portlogpdisc portlogreset portlogresize portlogshow portlogshowport portlogtypedisable portlogtypeenable portloopbacktest portmirror Cycle user port LEDs.Clear port activity logDisplay portlog configurationDisable portlog facilityPrint port log (no page breaks)Print port log (no page breaks)Enables port log facilityDisplay information about port log events Display port login informationSet or clear the debug_pdisc_flagEnable portlog facilityResize the port logPrint port activity logPrint port activity logDisable port loggingEnable port loggingFunctional test of port N->N path.Set a port's configuration to be disabled orenabled Assign or display the name associated with a port Print port throughput numbers Write/read test of the ASIC SRAMs portregtest. Display various routing tables for a port Show configured ip interfaces/routes/arp entries on the GigE Port Display the 64-bit hardware statistics for a port Clear the status of a specified switch port Print hardware statistics Swaps area numbers Disable portswap feature Enable portswap feature Display port and area information Functional test on a live fabric. Starts porttest. Retreive information from porttest. Displays the enforced zone type of the F/FL-ports of a switch. sets slot power off list order Displays slot power-off order. Print power supply status Displays/enables/disables quietmode on telnet session Reboot this processor Print routing help info Functional Test of Components in SAS Complex. Data Path Test of the SAS complex. Displays size of the active (security) database Creates/Manages DHCHAP secret key details Creates/Manages/Displays third party PKI certificates Displays size of the defined (security) database Displays security related fabric information Forces primary role to this FCS switch Displays current internal security state information Displays information about security commands Disables secure mode Enables secure mode Displays whether secure mode is enabled or disabled Sets the admin passwd for non-FCS switches Aborts changes to defined policy Activates all policy sets Adds members to an existing policyportnameportperfshowportregtestportrouteshow portshowportstats64show portstatsclearportstatsshowportswapportswapdisable portswapenable portswapshow porttestporttestshowportzoneshowpowerofflistset powerofflistshow psshowquietmodereboot routehelp saschiptestsaspathtestsecactivesizesecauthsecretseccertutilsecdefinesizesecfabricshow secfcsfailoversecglobalshow sechelpsecmodedisable secmodeenable secmodeshow secnonfcspasswd secpolicyabort secpolicyactivate secpolicyaddsecpolicycreate secpolicydeletesecpolicydump secpolicyfcsmove secpolicyremove secpolicysave secpolicyshow secstatsreset secstatsshow sectemppasswdreset sectemppasswdset sectransabort secversionreset sensorshow setdbg setesdmode setmfgmode setmodem Creates a new policy Deletes an existing policy Displays all members of existing policiesMoves a member in the FCS policyRemoves members from an existing policy Saves defined policy set and sends to all switches Shows members of one or more policies Resets security statisticsDisplays security statisticsResets temporary passwordSets temporary passwordAborts current transaction Resets version stamp Display sensor readingsSet debug level of the specified moduleSet or display ESD mode.Set or display diagnostic MFG mode.Enables or disables modem login to a controlprocessor (CP)setsplbmode setverbosesfpshow shellflowcontroldisableSet or display SPLB mode.Set verbosity level of the specified module Print Serial ID SFP informationDisable xon-xoff flow control on console serial portshellflowcontrolenable slotpoweroff slotpoweron slotshow sltest snmpconfig snmpmibcapset Enable xon-xoff flow control on console serial port Removes power from a slot.Restores power to a slot.Displays the status of all slots in the system.Serial link test of port N->N path.Configure SNMPSet options for configuring SNMP Mib/TrapCapabilitysnmpmibcapshow spinfabShow SNMP Mib/Trap Configuration Functional test of switch to switch ISL cabling and trunk group operation.spinjitter spinsilk line-speed jitter measurementFunctional test of internal and external transmitand receive paths at full speed sramretentiontest Data retention test of the miscellaneous SRAMs inASIC.statsclear statstest stopporttest supportffdc Clear port and diagnostic statistics.Statistics counter test for the ASICs. Terminate the running porttest.Modifies or displays first-failure data capture(FFDC) configuration.supportftp supportsave supportshow supportshowcfgdisableset support Ftp parametersretrieve support data from switch to hostPrints switch information for debugging purposes. Disables a group of commands under supportshow command.supportshowcfgenable Enables a group of commands under supportshowcommand.supportshowcfgshow Displays the groups of commands enabled fordisplay. by the supportshow command. switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switchswitchcfgpersistentenable switchcfgspeed Enable a persistently disabled switchConfigures all ports of the switch to a particular speed levelswitchcfgtrunk switchdisable switchenable switchname switchreboot switchshow switchstatuspolicyset switchstatuspolicyshow switchstatusshow switchuptimeConfigure all ports on the switch for trunkingDisable this switchEnable this switchPrint/set this switch's nameHalts and restarts the operational switch.Print switch and port statusSet policy parameters for overall switch statusPrint policy parameters for overall switch statusPrint overall switch statusDisplay the amount of time for which the switch is upsyslogdfacility syslogdipadd syslogdipremove syslogdipshow sysshutdown Change the syslog facilityAdd syslog daemon IP addressRemove syslog daemon IP addressPrint the syslog daemon targetsProvides a graceful shutdown to protect the switch file systems.systemverification Run a suit of diagnostic tests on all switches in asystem.tempshow timeout topologyshow tracedump Print temperature readingsSet/show the IDLE timeout value for a login session Display the unicast fabric topologygenerate/remove trace dump or display trace dump statustrackchangeshelp trackchangesset trackchangesshow trunkdebug trunkshow Print Track Changes help infoConfigure alert for login/logout/config update Displays status of track changesDebug a trunk link failureDisplay trunking informationtsclockserver Displays or sets the NTP server address tstimezone Displays or sets the time zoneturboramtest Turbo SRAM test for bloom ASICs.txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been upurouteconfig Configure a static routeurouteremove Remove a static routeurouteshow Display unicast routing informationuserconfig Display or configure user accountsuserrename Rename user login nameversion Print firmware versionwwn Display or set the world wide namezone Copies/Removes/Validates zone objects zoneadd Add a member to a zonezonecreate Create a zonezonedelete Delete a zonezonehelp Print zoning help infozoneobjectcopy Copies a zone objectzoneobjectexpunge Expunges a zone objectzoneobjectrename Rename a zoning Objectzoneremove Remove a member from a zonezoneshow Print zone information。
光纤交换机配置详解
光纤交换机配置详解目录第1章S A N结构的存储区域(Z O N E)的规划 (2)第2章通过C L I命令Z O N I N G (6)第3章通过图形化界面Z O N I N G (7)第4章激活端口 (8)第5章收集光纤交换机的配置信息 (9)5.1总体信息 (9)5.2Zone配置信息 (9)第6章网上参考文档 (10)6.1参考文档1 (10)6.2参考文档2 (11)6.3参考文档3 (17)第1章SAN结构的存储区域(ZONE)的规划在传统的没有SAN网络存在的系统中,网络中的各台主机是相互独立的,主机只能访问自己的硬盘,数据不会在存储级丧失安全性。
为了是SAN网络的可用性,在部署SAN架构的时候,一般都采用了冗余的架构,为了使这些可用的设备互不影响,,使主机访问存储设备路径的唯一性,需要对SAN架构中的存储设备,光纤交换机,主机划分不同的ZONE。
具体划分ZONE的方法详见下实例。
一号工程在实施之初大多数都采用如下的方案,这种方案存在一定的隐患,即光纤交换机没有冗余,这种方案如果不进行ZONE的设置,可能会导致系统不能使用存储阵列的情况。
我们建议个烟厂的系统管理员对一号工程的SAN网络进行检查,并对系统进行设置。
一.环境:DB2:HBA1/HBA2WAS:HBA1/HBA2FAST600:控制器A/控制器BSAN Switch: ibm h08或ibm h16二.配置原则:以一块HBA卡对应一个控制器的原则进行zone配置连接示意图三.具体配置操作步骤和方法:1. 用网线连接到交换机的管理口#telnet 10.77.77.77用户名:admin密码:password2. 查看交换机器端口连接#switchshowArea Port Media Speed State==============================0 0 id N2 Online F-Port 10:00:00:00:c9:42:a0:44(DB2_HBA1)1 1 id N2 Online F-Port 10:00:00:00:c9:45:b6:ea (DB2_HBA2)2 2 id N2 Online F-Port 20:05:00:a0:b8:18:d2:0a (WAS_HBA1)3 3 id N2 Online F-Port 20:04:00:a0:b8:18:d2:0a (WAS_HBA2)4 4 id N4 Online (控制器A)5 5 id N4 Online (控制器B)6 6 id N4 No_Light7 7 id N4 No_Light8 8 -- N4 No_Module (No POD License) Disabled3.划分zone输入以下命令zoneCreate "zone1","1,0;1,4"zoneCreate "zone2","1,1;1,5"zoneCreate "zone3","1,2;1,4"zoneCreate "zone4","1,3;1,5"cfgCreate "ibmp630","zone1;zone2; zone3; zone3" cfgEnable "ibmp630"cfgSave4.最后查看ZONE的划分做最后校验# zoneshowDefined configuration:cfg: ibmp630 zone1; zone1; zone1; zone1 zone: zone1 1,0; 1,4zone: zone2 1,1; 1,5zone: zone3 1,2; 1,4zone: zone4 1,3;1,5Effective configuration:cfg: ibmp630zone: zone1 1,01,4zone: zone2 1,11,5 zone: zone3 1,21,4 zone: zone4 1,31,5第2章通过cli命令zoning第3章通过图形化界面zoning第4章激活端口第5章收集光纤交换机的配置信息5.1 总体信息#switchshow例子1:例子2:5.2 Zone配置信息#zoneshow例子1:例子2:第6章网上参考文档6.1 参考文档1来源:/logs/14713887.html在SAN的环境中,光纤交换机(FC Switch)起着至关重要的作用,而FC Switch 的配置目前有GUI界面和CLI两种方式,GUI界面操作简单,但是花费时间较长,适合做较少配置时使用;CLI配置操作相对复杂,但是效率高,适合做大量配置时使用。
博科光纤交换机配置
Brocade光纤交换机配置1、通过telnet先观察一下交换机的状态在Windows任务栏上执行以下步骤:开始→运行→在运行栏中输入cmd→执行telnet 172.28.96.69(本台交换机的IP地址) (如下图)按回车(Enter)键后,输入用户名:admin,秘密:password(如下图)按回车(Enter)键后,输入switchshow命令,以检查交换机的状态(如下图)按回车(Enter)键后,显示交换机状态如下图port 0 ——15表示交换机是16口的;N2表示端口是自适应、2Gbde;Online表示端口的状态是正常;2、通过IE浏览器管理、配置交换机。
通过telnet检查状态正常后,打开IE浏览器,输入IP地址:172.28.96.69,按回车键(Enter)后,可以看到以下窗口点击在窗口的右上方的Status按钮可以显示交换机的状态(如下图)点击了按钮后,会弹出以下(如下图)对话框,如果对话框显示HEALTHY/OK表示交换机状态正常点击在窗口的右上方的Event按钮可以显示交换机的一些日志(如下图)点击了按钮后,会弹出以下(如下图)对话框,可以哪个时间点交换机做了哪些操作,是否有错误点击在窗口的右上方的Admin按钮可以以特权用户的身份登录交换机,并且可以配置交换机点击了按钮后,会弹出以下(如下图)对话框,用户名:admin,密码:password按确定后窗口显示如下,可以有Switch Information、Network Config、Upload/Download、SNMP、License Admin、Port Setting、Routing、Extended Fabric、User Admin、Config等选项,以下会介绍常用的几项在Switch Information 中可以了解到交换机的名字(Name),交换机的状态是不是启用的(Enable),以及交换机的序列号点击User Admin会显示以下窗口(如下图),在这里我们可以修改用户的密码点击Port Setting按钮可以看各个端口的状态,用户可以通过这个窗口改变端口的速度(Chang Speed),可以激活端口(Enable Port)或者关闭端口(Persistent Disable)3、Zone的划分。
博科_光纤交换机配置命令一览
DS_200B:admin> helpaaaconfig Configure RADIUS for AAA servicesad Specifies all administration domain (AD)-leveloperationsag Configure the Access Gateway featureagshow Displays the Access Gateway information registeredwith the fabricagtcfgdefault Reset SNMP agent to factory defaultaliadd Add a member to a zone aliasalicreate Create a zone aliasalidelete Delete a zone aliasaliremove Remove a member from a zone aliasalishow Print zone alias informationaptpolicy Get and set Advanced Performance Tuning policy auditcfg Modifies and displays audit log filterconfiguration.authutil Get and set authentication configuration backplanetest Backplane connection test for multi-blade systems. backport Test for back-end ASIC pair to ASIC pair links. bannerset Set security bannerbannershow Display security bannerbcastshow Display broadcast routing information bladebeacon Enables or disables blade beaconing or displays thecurrent mode.bladedisable Disables all user ports on a blade.bladeenable Enables all User Ports on a blade.burninerrclear Clear errors that are stored in the non-volatilestorageburninerrshow Display errors that are stored in the non-volatilestorageburninstatus Display the diagnostics burnin status.camtest Verify QuickLoop's Content Addressable Memory(CAM).SID translationcentralmemorytest Test ASIC central memory operation.cfgactvshow Display Effective zone configuration information cfgadd Add a member to a configurationcfgclear Clear all zone configurationscfgcreate Create a zone configurationcfgdelete Delete a zone configurationcfgdisable Disable a zone configurationcfgenable Enable a zone configurationcfgremove Remove a member from a configurationcfgsave Save zone configurations in flashcfgshow Print zone configuration informationcfgsize Print size details of zone databasecfgtransabort Abort zone configuration transaction cfgtransshow Print zone configurations in transaction buffer chassisconfig Display or set the chassis configuration chassisname Display or set the chassis's Namechassisshow Display all Field Replaceable Units (FRU) chipregshow Displays the port registers for a given chipnumber.cmemretentiontest Data retention test of the central memory SRAMs. cmitest Verify CMI bus between ASICs.configdefault Reset config to factory defaultconfigdownload Load switch config from a serverconfigshow Print switch config parametersconfigupload Save switch config to a serverconfigure Set switch config parametersdatatypeshow Display available diagnostic data types.date Print/set the system date and timedbgshow Display debug levels of various modules defzone Activates or deactivates a default zoneconfiguration.diagclearerror Clears diagnostics failure status. diagcommandshow Display diagnostic command descriptions. diagdisablepost Disable diagnostic POST.diagenablepost Enable diagnostic POST.diagenv Diagnostic debug parameters management package. diaghelp Display diagnostic command descriptions. diagloopid Select the diagnostics loop ID.diagmodeshow Displays diagnostic mode configuration. diagpost Displays the contents of port registers andmemories.diagretry Sets diagnostic retry modediagsetburnin Initializes the blade for a burnin run.diagsetcycle Set diagnostic script parameters. diagsetesdmode Set or display ESD mode.diagsetshowtime Set or display diagnostic show-time mode. diagshow Display diagnostic status.diagshowtime Set or display diagnostic show-time mode. diagstatus Display currently running diagnostic tests. diagstopburnin Terminate burnin run on a blade.distribute Distributes data to switches in a fabric.dlsreset Turn off the dynamic load sharing (DLS) option dlsset Turn on the dynamic load sharing (DLS) option dlsshow Display the state of the dynamic load sharingoptiondnsconfig Configure DNS serviceenclosureshow Display the switch enclosure attributes errclear Clear error logerrdelimiterset Sets the error log start and end delimiter formessages sent to the console and syslog errdump Print error log (no page breaks)errfilterset Sets a filter for an error log destination errmoduleshow Displays all the defined modules in the system errshow Print error logfabportshow Display contents of a particular port's data fabretryshow Display retry count of various fabric commands fabriclog Displays or manipulates the fabric log fabricprincipal Displays/Enables/Disables Principal SwitchSelection modefabricshow Print fabric membership infofabstateclear Clears the fabric state information fabstateresize Changes the number of state entries fabstateshow Displays the fabric state information fabstatsshow Displays the fabric statistics information fabswitchshow Display fabric switch state information fandisable Disables a fan unit.fanenable Enables a fan unit.fanshow Print fan statusfastboot Reboot this switch and bypass POST fastwritecfg Configure FC fastwrite featurefazoneadd Add a member to a fabric assist zone fazonecreate Create a fabric assist zonefazonedelete Delete a fabric assist zonefazoneremove Remove a member from a fabric assist zone fazoneshow Print Fabric Assist Zone information fcipchiptest Functional Test of Components in FCIP Complex. fciphelp Print FCIP help infofcippathtest Data Path Test of the FCIP complex.fcping Sends a FC ELS ECHO request to a port fcplogclear Clear the FCP logfcplogdisable Disable logging of FCP eventsfcplogenable Enable logging of FCP eventsfcplogshow Display FCP probing log information fcpprobeshow Display FCP probing information fcprlsshow Display FCP RLS (read link state) information fcrchiptest Functional Test of FCR FPGA.fcrconfigure Sets FC Router configuration parameters. fcrfabricshow Displays FC Routers on a backbone fabric. fcrlsancount Display maximum LSAN zone limit.fcrlsanmatrix Manage LSAN fabric matrix configuration. fcrpathtest Data Path Test on Connection between FCR FPGA andCentral ASIC.fcrphydevshow Displays FC Router physical device information. fcrproxyconfig Displays or configures proxy devices presented byan FC Router.fcrproxydevshow Displays FC Router proxy device information. fcrresourceshow Displays FC Router physical resource usage. fcrrouterportcost Displays FC Router route information.fcrrouteshow Displays FC Router route information. fcrxlateconfig Displays or persistently configures a translate(xlate) domain's domain ID for bothEX_Port-attached fabric and backbone fabric.fddcfg fddcfg manages the fabric data distributionconfiguration parameters.fdmicacheshow Display abbreviated remote FDMI device informationaccording to remote domain IDfdmishow Display detailed FDMI device information ficonclear Clears contents of the specified FICON managementdatabaseficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp Displays FICON commandsficonshow Displays contents of the specified FICON managementdatabasefiltertest Run frame filter test for bloom ASICs. firmwarecommit Commit firmware to stable storage firmwaredownload Download firmware into switch firmwaredownloadstatus Display the progress and status of firmwareDownload firmwarerestore Restore the old firmware in the switchfirmwareshow Display firmware versions in the switchfosconfig Enable/disable FabOS servicesfporttest Functional test of F->N N->F point to point path. framerpathtest Tests data path between ASICsfrureplace Replace a Field Replacable Unitfspfshow Print FSPF global informationfwalarmsfilterset Configure alarms filtering for Fabric Watch fwalarmsfiltershow Show alarms filtering for Fabric Watchfwclassinit Initialize all Fabric Watch classesfwconfigreload Reload Fabric Watch configurationfwconfigure Configure Fabric Watchfwfrucfg Configure FRU state and notificationfwhelp Print Fabric Watch help infofwmailcfg Configure Fabric Watch Email Alertfwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor informationfwset Set port persistence timefwsettocustom Set boundary & alarm level to custom fwsettodefault Set boundary & alarm level to defaultfwshow Show thresholds monitored and port persistence time grep Linux grep commandh Print shell historyhadisable Disables the High Availability feature in theswitch.hadump Displays information about the status of the HighAvailability feature in the switch.haenable Enables the High Availability feature in the switch hafailover Forces the failover mechanism so that the StandbyControl Processor (CP)becomes the Active CP. hashow Displays control processor (CP) status hasyncstart Enables HA state synchronization.hasyncstop Disables the HA state synchronization.help Print this listhistorylastshow Displays last history recordhistorymode Display or set the mode of the history log historyshow Displays entire history loghttpcfgshow Used to show the version of the Java plug-in usedby the Webtoolsi Display process summaryifmodeset Set the link operating mode for a network interface ifmodeshow Display the link operating mode for a networkinterfaceinterfaceshow Display the FSPF (TM) interface information interopmode Displays/enables/disables Brocade switchinteroperability with switches from othermanufacturersiodreset Turn off the in-order delivery (IOD) optioniodset Turn on the in-order delivery (IOD) optioniodshow Display the state of the in-order delivery option ipaddrset Set ethernet and FC IP addressesipaddrshow Print ethernet and FC IP addressesipfilter Manage/display IP filtersiscsihelp Print iSCSI help infoislshow Display the current connections and statuskilltelnet Terminate telnet/serial login sessionsinteractivelylicenseadd Adds license keys to switchlicensehelp Print license help infolicenseidshow Displays the system license IDlicenseport Configure per-port POD license assignments licenseremove Removes a license key from this system licenseshow Displays current license keyslinkcost Set or print the FSPF cost of a linklogin Login as a new userlogout Logout from remote sessionloopporttest Functional test of L-port M->M path on a loop. lsdbshow Displays the FSPF link state databasememshow Display memory usage in the system.minicycle Functional test of internal and external transmitand receive paths at full speed.minispropshow Displays ASIC pair properties.more Linux more commandmscapabilityshow Display Management Server Capability. msconfigure Configure Management Servermsplatshow Display the Management Server Platform Database msplatshowdbcb Display the Management Server Database ControlBlockmsplcleardb Clear the Management Server Platform Databasefabric-widemsplmgmtactivate Activate the Management Server Platform Databasefabric-widemsplmgmtdeactivate Deactivate the Management Server Platform Databasefabric-widemstddisable Disables the Management Server Topology DiscoveryManagement Servicemstdenable Enables the Management Server Topology DiscoveryManagement Servicemstdreadconfig Display status of Management Server TopologyDiscovery Servicemyid Display the current login session details nbrstateshow Display FSPF (TM) neighbors' states nbrstatsclear Reset the FSPF (TM) interface countersnetstat Display network connections and statisticsnodefind Display all the devices' PID matching the givenworld wide namensaliasshow Display local Name Server information with Aliases nsallshow Print global Name Server information nscamshow Print local Name Server Cache information nsshow Print local Name Server information information nszonemember Display the information of all the online deviceswhich are zoned with the given device. opensource Display information on open source softwareutilized in FabOSpasswd Set usernames and passwordspasswdcfg passwdcfg manages the password policies. pathinfo Display routing information between two ports pdshow Show information from Panic Dump file perfaddeemonitor Add end-to-end monitorperfaddipmonitor Add monitor for IP trafic frame count perfaddreadmonitor Add filter-based monitor - SCSI Read perfaddrwmonitor Add monitor - SCSI Read and Write perfaddscsimonitor Add monitor for SCSI frame count perfaddusermonitor Add filter-based monitorperfaddwritemonitor Add filter-based monitor - SCSI Write perfcfgclear Clear Performance settings from FLASH perfcfgrestore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH perfclearalpacrc Clears the CRC error count associated with a portand Arbitrated Loop Physical Address (AL_PA). perfcleareemonitor Clears statistics counters of one or moreend-to-end performance monitors. perfclearfiltermonitor Clears counters of one or more filter-basedperformance monitors.perfdeleemonitor Delete end-to-end monitorperfdelfiltermonitor Delete filter-based monitorperfhelp Print Performance Monitoring help info perfmonitorclear Clear end-to-end/filter-based/ISL monitors perfmonitorshow Show end-to-end/filter-based/ISL monitors perfsetporteemask Set overall mask for end-to-end monitors perfshowalpacrc Get ALPA CRC count by port and ALPA perfshoweemonitor Show user-defined end-to-end monitors perfshowfiltermonitor Show filter-based monitors perfshowporteemask Show the current end-to-end maskpkicreate Creates public key infrastructure (PKI) objects pkiremove Removes existing public key infrastructure (PKI)objectspkishow Displays existing public key infrastructure (PKI)objectspolicy Configure IPSec encryption and authenticationalgorithmsportalpashow Show the ALPAs of a portportbuffershow Print the buffer allocations for the ports of aquadportcamshow Display filter utilizationportcfg Create/Delete a new ip interface/route/arp entry onthe GigE portportcfgdefault Restore the port configuration to defaults portcfgeport Enable/Disable a port from becoming E_Port portcfgexport Sets a port to be an EX_Port and sets and displaysEX_Port configuration parameters. portcfggport Lock a port as a G_Portportcfgislmode Configure a port to be ISL R_RDY Modeenabled/disabledportcfglongdistance Configure a Long Distance Portportcfglport Lock a port as a L_Portportcfgnpivport Enables and disables NPIV functionality on a port. portcfgnport Enable/disable N_Port capability for a port portcfgpersistentdisable Persistently disable a port portcfgpersistentenable Enable a persistently disabled portportcfgshow Displays port configuration settings. portcfgspeed Configure a port to a particular speed level portcfgtrunkport Configure a port for trunkingportcfgvexport Sets a port to be an VEX_Port connected to FC-IPand sets and displays VEX_Port configurationparameters.portcmd Execute commands (ping etc) on the GigE port portdebug Set debug level and verbosity level of port modules portdisable Disable a specified portportenable Enable a specified portporterrshow Print port error summaryportflagsshow Display the port status bitmaps of all ports in aswitchportledtest Cycle user port LEDs.portlogclear Clear port activity logportlogconfigshow Display portlog configurationportlogdisable Disable portlog facilityportlogdump Print port log (no page breaks) portlogdumpport Print port log (no page breaks)portlogenable Enables port log facilityportlogeventshow Display information about port log events portloginshow Display port login informationportlogpdisc Set or clear the debug_pdisc_flagportlogreset Enable portlog facilityportlogresize Resize the port logportlogshow Print port activity logportlogshowport Print port activity logportlogtypedisable Disable port loggingportlogtypeenable Enable port loggingportloopbacktest Functional test of port N->N path.portmirror Set a port's configuration to be disabled orenabledportname Assign or display the name associated with a port portperfshow Print port throughput numbersportregtest Write/read test of the ASIC SRAMs portregtest. portrouteshow Display various routing tables for a portportshow Show configured ip interfaces/routes/arp entries onthe GigE Portportstats64show Display the 64-bit hardware statistics for a port portstatsclear Clear the status of a specified switch port portstatsshow Print hardware statisticsportswap Swaps area numbersportswapdisable Disable portswap featureportswapenable Enable portswap featureportswapshow Display port and area informationporttest Functional test on a live fabric. Starts porttest. porttestshow Retreive information from porttest.portzoneshow Displays the enforced zone type of the F/FL-portsof a switch.powerofflistset sets slot power off list orderpowerofflistshow Displays slot power-off order.psshow Print power supply statusquietmode Displays/enables/disables quietmode on telnetsessionreboot Reboot this processorroutehelp Print routing help infosaschiptest Functional Test of Components in SAS Complex. saspathtest Data Path Test of the SAS complex.secactivesize Displays size of the active (security) database secauthsecret Creates/Manages DHCHAP secret key details seccertutil Creates/Manages/Displays third party PKIcertificatessecdefinesize Displays size of the defined (security) database secfabricshow Displays security related fabric information secfcsfailover Forces primary role to this FCS switch secglobalshow Displays current internal security stateinformationsechelp Displays information about security commands secmodedisable Disables secure modesecmodeenable Enables secure modesecmodeshow Displays whether secure mode is enabled or disabled secnonfcspasswd Sets the admin passwd for non-FCS switches secpolicyabort Aborts changes to defined policysecpolicyactivate Activates all policy setssecpolicyadd Adds members to an existing policysecpolicycreate Creates a new policysecpolicydelete Deletes an existing policysecpolicydump Displays all members of existing policies secpolicyfcsmove Moves a member in the FCS policy secpolicyremove Removes members from an existing policy secpolicysave Saves defined policy set and sends to all switches secpolicyshow Shows members of one or more policies secstatsreset Resets security statisticssecstatsshow Displays security statistics sectemppasswdreset Resets temporary password sectemppasswdset Sets temporary passwordsectransabort Aborts current transactionsecversionreset Resets version stampsensorshow Display sensor readingssetdbg Set debug level of the specified module setesdmode Set or display ESD mode.setmfgmode Set or display diagnostic MFG mode. setmodem Enables or disables modem login to a controlprocessor (CP)setsplbmode Set or display SPLB mode.setverbose Set verbosity level of the specified module sfpshow Print Serial ID SFP information shellflowcontroldisable Disable xon-xoff flow control on console serialportshellflowcontrolenable Enable xon-xoff flow control on console serial port slotpoweroff Removes power from a slot.slotpoweron Restores power to a slot.slotshow Displays the status of all slots in the system. sltest Serial link test of port N->N path.snmpconfig Configure SNMPsnmpmibcapset Set options for configuring SNMP Mib/TrapCapabilitysnmpmibcapshow Show SNMP Mib/Trap Configurationspinfab Functional test of switch to switch ISL cabling andtrunk group operation.spinjitter line-speed jitter measurementspinsilk Functional test of internal and external transmitand receive paths at full speed sramretentiontest Data retention test of the miscellaneous SRAMs inASIC.statsclear Clear port and diagnostic statistics.statstest Statistics counter test for the ASICs.stopporttest Terminate the running porttest.supportffdc Modifies or displays first-failure data capture(FFDC) configuration.supportftp set support Ftp parameterssupportsave retrieve support data from switch to host supportshow Prints switch information for debugging purposes. supportshowcfgdisable Disables a group of commands under supportshowcommand.supportshowcfgenable Enables a group of commands under supportshowcommand.supportshowcfgshow Displays the groups of commands enabled fordisplay. by the supportshow command. switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switch switchcfgpersistentenable Enable a persistently disabled switch switchcfgspeed Configures all ports of the switch to a particularspeed levelswitchcfgtrunk Configure all ports on the switch for trunking switchdisable Disable this switchswitchenable Enable this switchswitchname Print/set this switch's nameswitchreboot Halts and restarts the operational switch. switchshow Print switch and port status switchstatuspolicyset Set policy parameters for overall switch status switchstatuspolicyshow Print policy parameters for overall switch status switchstatusshow Print overall switch statusswitchuptime Display the amount of time for which the switch isupsyslogdfacility Change the syslog facilitysyslogdipadd Add syslog daemon IP address syslogdipremove Remove syslog daemon IP address syslogdipshow Print the syslog daemon targetssysshutdown Provides a graceful shutdown to protect the switchfile systems.systemverification Run a suit of diagnostic tests on all switches in asystem.tempshow Print temperature readingstimeout Set/show the IDLE timeout value for a login session topologyshow Display the unicast fabric topologytracedump generate/remove trace dump or display trace dumpstatustrackchangeshelp Print Track Changes help infotrackchangesset Configure alert for login/logout/config update trackchangesshow Displays status of track changestrunkdebug Debug a trunk link failuretrunkshow Display trunking informationtsclockserver Displays or sets the NTP server addresststimezone Displays or sets the time zoneturboramtest Turbo SRAM test for bloom ASICs.txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been upurouteconfig Configure a static routeurouteremove Remove a static routeurouteshow Display unicast routing informationuserconfig Display or configure user accountsuserrename Rename user login nameversion Print firmware versionwwn Display or set the world wide namezone Copies/Removes/Validates zone objectszoneadd Add a member to a zonezonecreate Create a zonezonedelete Delete a zonezonehelp Print zoning help infozoneobjectcopy Copies a zone objectzoneobjectexpunge Expunges a zone objectzoneobjectrename Rename a zoning Objectzoneremove Remove a member from a zonezoneshow Print zone information。
光纤交换机配置
1.下载并安装jre 1.6u_x版本的Java配置本地网卡IP为10.77.77.0网段的IP,以便与光交管理口10.77.77.77相连(完成配置后,能ping通,说明能相连)2.将服务器的FC-HBA1和FC-HBA2分别接上光纤,光纤的另一端分别与光纤交换机的端口port0-1和port0-2相连。
再将光交的端口port1-1和port1-2分别与EMC存储VNX5200的控制器A和控制器B相连,连接如下图:3.配置光纤交换机:划分zone 登录的用户名:admin密码:password配置方法有2种:web登录后通过图形进行配置ssh或telnet登录后,通过命令行CLI镜像配置(1)web登录:直接浏览器输入10.77.77.77 然后输入用户名和密码,就通过图形登录光交点击zone,然后点击new,会弹出需要新建的zone的名字,输入新的名字,再点击member selection list将需要添加的端口添加到其中,这里添加port0-1,port1-1到新建的zone1里面添加port0-2,port1-2到新建的zone2里面最后,saveconfig ---- enabled zone使配置生效(2)CLI登录:直接通过putty,xshell等工具ssh到10.77.77.77,或通过cmd进行telnet到10.77.77.77,输入用户名admin,密码password用命令switchshow查看交换机相关信息创建别名alicreate”易于记的名字” , ”端口号或WWN号”这里alicreate ”controlA_port0-1” , ”0,1”alicreate ”controlA_port1-1” , ”1,1”再创建zonezonecreate “zone的名字”, “别名;端口号”创建 zone,端口用分号隔开,其中把刚才用别名创建的端口和交换机自身的域为0,端口号为1的端口都加入进去zonecreate”zone1”, ”0-1;1-1”cfgcreate "zone1_cfg","zone1"(创建zone 配置文件)启用配置文件cfgenable zone1_cfg保存配置cfgsave。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1.1.1.配置过程
FC_SW1:admin> zonecreate "vm1","1,2;1,4"
FC_SW1:admin> zonecreate "vm01","1,3;1,4"
FC_SW1:admin> zonecreate "vm2","1,2;1,5"
FC_SW1:admin> zonecreate "vm02","1,3;1,5"
FC_SW1:admin> zonecreate "vm3","1,2;1,6"
FC_SW1:admin> zonecreate "vm03","1,3;1,6"
FC_SW1:admin> zonecreate "oadb1","1,2;1,7"
FC_SW1:admin> zonecreate "oadb01","1,3;1,7"
FC_SW1:admin> zonecreate "oadb2","1,2;1,8"
FC_SW1:admin> zonecreate "oadb02","1,3;1,8"
FC_SW1:admin> cfgcreate
"conf1","vm1;vm2;vm3;oadb1;oadb2;vm01;vm02;vm03;oadb01;oadb02"
FC_SW1:admin> cfgenable conf1
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected. If the update includes changes
to one or more traffic isolation zones, the update may result in
localized disruption to traffic on ports associated with
the traffic isolation zone changes
Do you want to enable 'conf1' configuration (yes, y, no, n): [no] y
zone config "conf1" is in effect
Updating flash ...
FC_SW1:admin> cfgsave
You are about to save the Defined zoning configuration. This
action will only save the changes on Defined configuration.
Do you want to save the Defined zoning configuration only? (yes, y, no, n): [no] y Nothing changed: nothing to save, returning ...
FC_SW1:admin > reboot
Warning: This command would cause the switch to reboot
and result in traffic disruption.
Are you sure you want to reboot the switch [y/n]?y
Broadcast message from root (pts/0) Mon Jun 7 05:14:18 2014...
The system is going down for reboot NOW !!
1.1.
2.配置信息
两台光纤交换机的配置相同,下面列举一台光交的配置
FC_SW1:admin> zoneshow
Defined configuration:
cfg: conf1 vm1; vm2; vm3; oadb1; oadb2; vm01; vm02; vm03; oadb01; oadb02 zone: oadb01 1,3; 1,7
zone: oadb02 1,3; 1,8
zone: oadb1 1,2; 1,7
zone: oadb2 1,2; 1,8
zone: vm01 1,3; 1,4
zone: vm02 1,3; 1,5
zone: vm03 1,3; 1,6
zone: vm1 1,2; 1,4
zone: vm2 1,2; 1,5
zone: vm3 1,2; 1,6
alias: vnx5100 1,0; 1,1
alias: vnx5300 1,2; 1,3
Effective configuration:
cfg: conf1
zone: oadb01 1,3
1,7
zone: oadb02 1,3
1,8 zone: oadb1 1,2
1,7 zone: oadb2 1,2
1,8 zone: vm01 1,3
1,4 zone: vm02 1,3
1,5 zone: vm03 1,3
1,6 zone: vm1 1,2
1,4 zone: vm2 1,2
1,5 zone: vm3 1,2
1,6。